MBmag型电磁流量转换器使用说明-2010版

合集下载

RPMAG60系列智能电磁流量计说明书2012

RPMAG60系列智能电磁流量计说明书2012
途及范围 ....................................................................................................................................... 2 1.1 用途.......................................................................................................................................................... 2 1.2 产品特点.................................................................................................................................................. 2 1.3 适应范围.................................................................................................................................................. 2 1.4 工作条件.................................................................................................................................................. 2 2 主要规格及技术参数 .....................

电磁流量计转换器511L-Mag系列

电磁流量计转换器511L-Mag系列
1.1 基本功能............................................................................................................................... 1 1.2 特殊功能............................................................................................................................... 1 1.3 正常工作条件....................................................................................................................... 1 1.4 与传感器连接型式................................................................................................................1 1.5 安装尺寸图........................................................................................................................... 2
9.2 运输和贮存........................................................................................................................ 34 附录 1 励磁频率选择(参考)................................................................................................... 35 附录 2 L_ MAG511 转换器 HART 功能说明..............................................................................37 附录 3 流量系数修改记录功能................................................................................................... 38 附录 4 带非线性修正功能补充说明.............................................................................................39 附录 5 防雷功能说明...................................................................................................................40

电磁流量计说明书

电磁流量计说明书

一、概述智能电磁流量计由传感器和转换器两部分构成。

它是基于法拉第电磁感应定律工作的,用来测量电导率大于5μS/cm导电液体的体积流量,是一种测量导电介质体积流量的感应式仪表。

除可测量一般导电液体的体积流量外,还可用于测量强酸强碱等强腐蚀液体和泥浆、矿浆、纸浆等均匀的液固两相悬浮液体的体积流量。

广泛应用于石油、化工、冶金、轻纺、造纸、环保、食品等工业部门及市政管理,水利建设、河流疏浚等领域的流量计量。

二、工作原理根据法拉第电磁感应原理,在与测量管轴线和磁力线相垂直的管壁上安装了一对检测电极,当导电液体沿测量管轴线运动时,导电液体切割磁力线产生感应电势,此感应电势由两个检测电极检出,数值大小与流量成正比例,其值为:E=KBVD式中:E-感应电势;K-与磁场分布及轴向长度有关的系数;B-磁感应强度;V-导电液体平均流速;D-电极间距;(测量管内直径)传感器将感应电势E作为流量信号,传送到转换器,经放大,变换滤波用一系列的数字处理后,用带背光的点阵式液晶显示瞬时流量和累积流量。

转换器有4~20mA输出,报警输出及频率输出,并设有RS-485等通讯接口,并支持HART和MODBUS协议。

三、产品特点●全数字量处理,抗干扰能力强,测量可靠,精度高、流量测量范围可达150:1●超低EMI开关电源,适用电源电压变化范围大,抗EMI性能好。

●采用16位嵌入式微处理器,运算速度快,精度高,可编程频率低频矩形波励磁,提高了流量测量的稳定性,功耗低。

●采用SMD 器件和表面贴装(SMT)技术,电路可靠性高。

●管道内无可动部件,无阻流部件,测量中几乎没有附加压力损失。

●在现场可根据用户实际需要在线修改量程。

●测量结果与流速分布,流体压力,温度、密度、粘度等物理参数无关。

●高清晰度背光LCD 显示,全中文菜单操作,使用方便,操作简单,易学易懂。

●具有RS485、RS232、Hart 和Modbus 等数字通讯信号输出。

(选配)●具有自检与自论断功能。

上海舒电自动化技术有限公 MAGFLOW-MA系列电磁流量传感器 说明书

上海舒电自动化技术有限公 MAGFLOW-MA系列电磁流量传感器 说明书

MAGFLOW-MA系列电磁流量传感器使用说明书上海舒电自动化技术有限公司 SHANGHAI SUPERDIAN AUTOMATION TECHNOLOGY CO.,LTD目录CONTENTS1.工作原理 (2)2.主要特点和用途 (2)3.结构 (3)4.外型和安装尺寸 (4)5.流量计规格 (6)6.安装 (7)7.运行前的准备工作 (12)8.维护和常见故障处理 (12)9.开箱和产品成套性 (13)10.质量保证 (14)11.运输和贮存 (14)12.订货须知 (14)13.配套仪表编号及型号 (14)本产品执行Q/SSTU1-2006 MAGFLOW系列电磁流量计企业标准注意: · 在安装、使用、维修前必须详细阅读本说明书!· 为了确保您的流量测量系统正常运行,请务必保证测量管道和传感器中充满介质。

(如有修改,不另行通知)1.工作原理传感器是根据法拉第电磁感应定律工作的,如图1所示:图1. 工作原理图当导电液体沿测量管在交变磁场与磁力线成垂直方向运动时,导电液体切割磁力线产生感应电势。

在与测量管轴线和磁场磁力线相互垂直的管壁上安装了一对检测电极,将这个感应电势检出。

若感应电势为E,则有:E=BVD ⑴ 式中:B…磁感应强度;D…电极间的距离,与测量管内径相等; V…测量管内径被测流体在截面上的平均流速。

式⑴中磁场B 是恒定不变,D 为一常数,则感应电动势E 与被测流体流速V 成正比。

通过测量管横截面上的瞬时体积流量Q 与流速V 之间的关系为:Q=42D π·V ⑵将式⑴代入式⑵得: Q=BD4π·E=K ·E ⑶式中:K…仪表常数E 通常称为流量信号,将流量信号输入转换器,经处理输出与流量成正比的0~10mA 或4~20mA 电流信号、脉冲(或频率)信号,可对流量进行记录、调节等。

2.主要特点和用途MAGFLOW-MA 型系列电磁流量传感器与MAGFLOW-MC 型系列电磁流量转换器配套组成MAGFLOW 型系列型电磁流量计,用于测量各种酸、碱、盐溶液、纸浆、泥浆等导电液体或液固两相介质的体积流量。

Proline Promag 50L电磁流量测量系统用户手册说明书

Proline Promag 50L电磁流量测量系统用户手册说明书

TI00097D/28/zh/16.11技术资料Proline Promag 50L电磁流量测量系统水或污水测量场合中的液体流量测量应用电磁流量计可以进行液体的双向流量测量,被测液体的最小电导率应 5 μS/cm :•饮用水•污水•污泥•流量测量可达162 ,000 m³/h (713 ,000 gal/min)•流体温度可达+90 °C (+194 °F)•过程压力可达16 bar (232 psi)•装配长度符合DVGW/ISO 标准 (DVGW :德国气体与水协会)专用测量管内衬采用聚氨酯、硬橡胶或PTFE 材料,通过下列饮用水认证:•KTW •WRAS •NSF •ACS与过程控制系统的连接接口:•HART•PROFIBUS DP/PA优势Promag 系列流量计可以在多种不同的过程条件下进行高精度测量,是一种经济的流量测量解决方案。

Proline 系列变送器具有下列优点:•采用模块化结构设计和操作方法,变送器具有更高的测量效率•电极清洗软件可选•统一的操作模式Promag 系列传感器经过多次试验和测试,具有下列优点:•无压损•抗振性强•安装和调试简便Proline Promag 50L2Endress+Hauser目录功能与系统设计 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3测量原理 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3测量系统 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3输入 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4测量变量 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4测量范围 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4量程比 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4输入信号 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4输出 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5输出信号 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5报警信号 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5负载 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5小流量切除 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5电气隔离 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5开关输出 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5电源 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6测量单元的电气连接 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6接线端子分配 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7分体式仪表的电气连接 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7供电电压(电源) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7电缆入口 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7电缆规格(分体式仪表用) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8功率消耗 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9电源故障 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9电势平衡 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9性能参数 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11参考操作条件 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11最大测量误差 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11重复性 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11操作条件:安装 . . . . . . . . . . . . . . . . . . . . . . . . . . . .12安装指南 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12前后直管段 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15连接管 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16连接电缆长度 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17操作条件:环境 . . . . . . . . . . . . . . . . . . . . . . . . . . . .18环境温度范围 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18储存温度 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18防护等级 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18抗冲击性和抗振性 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18电磁兼容性(EMC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18操作条件:过程 . . . . . . . . . . . . . . . . . . . . . . . . . . . .19介质温度范围 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19电导率 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19介质压力范围 (标称压力) . . . . . . . . . . . . . . . . . . . . . . . . . . . 19密闭压力 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19限流值 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19压损 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21机械结构 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22设计及外形尺寸 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22重量 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34测量管规格 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37材料 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39材料负载曲线 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39配套电极 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41过程连接 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41表面光洁度 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41人机界面 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41显示单元 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41操作单元 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41语言组 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41远程操作 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41证书和认证 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42CE 认证 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42C-Tick 认证 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42饮用水认证 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42PROFIBUS DP/PA 认证 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42其他标准和准则 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42订购信息 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42附件 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43文档资料 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43注册商标 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43Proline Promag 50LEndress+Hauser 3功能与系统设计测量原理根据法拉第电磁感应定律,导体在磁场中运动时,会产生感应电压。

电磁流量计按纽操作说明

电磁流量计按纽操作说明

电磁流量计转换器按钮操作说明一.各键功能说明1.C/CE键:其用作工作模式与菜单模式之间的切换。

工作模式为其正常显示状态,即液晶显示第一行为瞬时流量,第二行累计流量状态。

〈显示格式可用DISPLAY菜单设定〉2.STEP键:此键处于三个键的中间位置,作用是进入菜单后通过此键可对整个菜单正向滚动,在修改数据项时控制光标移位。

3.DATA键:此键用于对整个菜单的反向滚动和数据修改时对各位数据的调整。

其中DATA键也具有ENTER的作用,主要用于逐级进入各级菜单和修改后进行确认与存储。

〈操作时要按住至少3秒〉二下面以实际操作为例来说明各个键的具体用法。

1.修改量程按一下C/CE键由显示模式进入菜单模式,用STEP或DATA键翻动菜单到“PROG。

PROTECTION〈程序保护〉”将ON〈开〉变为OFF〈关〉,只需按住ENTER键3秒即可。

然后用STEP或DATA翻动菜单到“RANG”菜单项。

如原量程为400M3/H,我们要改为800M3/H,则首先按住ENTER键3秒,则400变为0,且在0下面有一个光标,此时输入数字,短按ENTER键,数字变为1 、2 、3 、4 、5 、6 、7 、8因此利用ENTER键可以循环修改数据。

利用STEP键按一下变为80 再按一下,光标再右移一位,变为800 。

STEP键在修改数据时用于移动光标。

相应位上数据通过ENTER键来修改。

然后用ENTER键按住3秒存储数据,再按C/CE键退到显示模式。

2.设定单位首先用C/CE进入菜单模式,翻到“UNIT”〈单位〉子菜单,按住“ENTER”键3秒,进入下一级子菜单,第一项为“RANG UNIT”菜单〈瞬时流量单位〉,按住“ENTER”键3秒,在现有单位下出现一个光标,此时翻动菜单会出现很多待选单位,当你选中后,按住“ENTER”键3秒,将此单位存储。

后按一下C/CE退到上一级“RANG UNIT”菜单,用STEP或DATA键,翻到第二项“TOTALIZER UNIT”〈累积量单位〉,按住“ENTER”键3秒,进入下一级菜单修改单位,修改方法同第一项。

电磁流量计MBmagCPV4 485通讯简本

电磁流量计MBmagCPV4 485通讯简本

MBmagCPV4.2 485通讯协议MBmag 电磁流量计的网络通讯接口为半双工方式,标准通讯速率大于250khz,通讯方向转换时间3.5μS。

通讯接口电气标准遵从RS232/RS485国际标准。

该版本主要用于实时数据采集、流量测量及流量累计控制。

MBmagCP V4.2协议可用于星型式网络结构和总线式网络结构。

标准通讯连接介质为屏蔽双绞线。

一、MBmagCP V4.2主机信息结构MBmagCP V4.2协议为主从扫描式通讯协议,每次通讯过程均由主机发起(4字节组成),然后从机进行响应,回传(10字节)规定的信息,完成一次通讯过程。

例如:主机发送:2a 03 01 2e ,表明主机要查询通讯地址为03的流量计的瞬时流速。

二、MBmagCP V4.2从机信息结构从机接受到主机命令信息后,按命令要求回传测量数据。

结束标志四部分。

以下用通讯地址为03#的仪表为例说明:1.瞬时流速m/s4.正向总量(略)7.接线:分体:A 485输出+ B 485输出- 一体:T+ 485输出+ T- 485输出-MODBUS总路线通讯协议我公司电磁流量转换器MODBUS通讯采用标准MODBUS通讯协议,MODBUS模块和上位机进行通讯的波特率为600 –19200,波特率、设备地址可以通过键盘进行设置。

我公司的Modbus通讯是采用的RTU(REMOTE TERMINAL UNIT)模式。

通讯由主机发起,主机首先发送消息帧:04---读键盘参数;0AH(10)---空管电阻06---设置键盘参数ODH(13)---正向累积10H(16)---反向累积13H(19)---仪表口径16H(22)---报警状态从机分别响应:(设从机通讯地址为01H)瞬时流量小数部分瞬时流量整数部分低4位瞬时流量整数部分高4位读出的字节个数正向累积。

ABB MagMasterTM电磁流量计使用指南

ABB MagMasterTM电磁流量计使用指南

Electromagnetic FlowmetersMagMaster TMInstruction Manual –BOOK 5 Fault FindingIM/MM/BK5_6ABBThe CompanyWe are an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid analysis and environmental applications.As a part of ABB, a world leader in process automation technology, we offer customers application expertise, service and support worldwide.We are committed to teamwork, high quality manufacturing, advanced technology and unrivalled service and support.The quality, accuracy and performance of the Company’s products result from over 100 years experience, combined with a continuous program of innovative design and development to incorporate the latest technology.The UKAS Calibration Laboratory No. 0255 is just one of the ten flow calibration plants operated by the Company and is indicative of our dedication to quality and accuracy.Use of InstructionsEN ISO 9001:2000Cert. No. Q 05907EN 29001 (ISO 9001)Lenno, Italy – Cert. No. 9/90AStonehouse, U.K.CONTENTS PageBOOK 5FAULT FINDINGSection Page SAFETY MEASURES (1)1INTRODUCTION (1)2FAULT FINDING (2)2.1Alarms (2)2.2Test Mode (2)2.3Fault Finding Flow Chart.................................3A very powerful test mode, especially useful during commissioning and plant fault finding, enables all external devices connected to the MagMaster to be tested over the full range of flow rates.This mode can be used regardless of flow conditions in the sensor, or even with the sensor disconnected, and does not require the use of additional equipment.1INTRODUCTIONSAFETY MEASURESMESURES DE SÉCURITÉ12FAULT FINDING2.1AlarmsThe transmitter has built in diagnostics with alarm indication which interrupts the transmitter local display. A data terminal connected to the transmitter will display these alarms in ‘Read Alm’ parameter; ‘16’ from Main Menu (see Warning in next column).The table below shows possible alarm indications and Fig. 2.1 Fault Finding Flow Chart indicates checking procedures to find the problems causing the alarms.For method of interrogating the local display see Startup Section in Book 4.Table 2.1Possible Alarm IndicationsDisplay AlarmMtSnsr Empty SensorHi High flowLo Low flowAnlg Analogue over rangePls Pulse frequency limitedCoil Sensor Coil open circuit19, 20, 21See Fault Finding Flow Chart2FAULT FINDING 2.3Fault Finding Flow Chart3NOTES 4PRODUCTS & CUSTOMER SUPPORTProductsAutomation Systems•for the following industries:–Chemical & Pharmaceutical–Food & Beverage–Manufacturing–Metals and Minerals–Oil, Gas & Petrochemical–Pulp and PaperDrives and Motors•AC and DC Drives, AC and DC Machines, AC motors to 1kV •Drive systems•Force Measurement•Servo DrivesControllers & Recorders•Single and Multi-loop Controllers•Circular Chart , Strip Chart and Paperless Recorders •Paperless Recorders•Process IndicatorsFlexible Automation•Industrial Robots and Robot SystemsFlow Measurement•Electromagnetic Flowmeters•Mass Flow Meters•Turbine Flowmeters•Flow ElementsMarine Systems & Turbochargers•Electrical Systems•Marine Equipment•Offshore Retrofit and RefurbishmentProcess Analytics•Process Gas Analysis•Systems IntegrationTransmitters•Pressure•Temperature•Level•Interface ModulesValves, Actuators and Positioners•Control Valves•Actuators•PositionersWater, Gas & Industrial Analytics Instrumentation•pH, conductivity, and dissolved oxygen transmitters and sensors•ammonia, nitrate, phosphate, silica, sodium, chloride, fluoride, dissolved oxygen and hydrazine analyzers.•Zirconia oxygen analyzers, katharometers, hydrogen purity and purge-gas monitors, thermal conductivity.Customer SupportWe provide a comprehensive after sales service via a Worldwide Service Organization. Contact one of the following offices for details on your nearest Service and Repair Centre. United KingdomABB LimitedTel: +44 (0)1453 826661Fax: +44 (0)1453 829671United States of AmericaABB Inc.Tel: +1 (0) 755 883 4366Fax: +1 (0) 755 883 4373Client WarrantyPrior to installation, the equipment referred to in this manual must be stored in a clean, dry environment, in accordance with the Company's published specification.Periodic checks must be made on the equipment's condition. In the event of a failure under warranty, the following documentation must be provided as substantiation:1.A listing evidencing process operation and alarm logs at timeof failure.2.Copies of all storage, installation, operating and maintenancerecords relating to the alleged faulty unit.I M /M M /B K 5I s s u e 6ABB LimitedOldends Lane, Stonehouse Gloucestershire GL10 3TA UKTel:+44 (0)1453 826661Fax:+44 (0)1453 829671ABB Inc.125 E. County Line Road Warminster PA 18974USATel:+1 215 674 6000Fax:+1 215 674 7183ABB has Sales & Customer Supportexpertise in over 100 countries worldwide The Company’s policy is one of continuous product improvement and the right is reserved to modify theinformation contained herein without notice.Printed in UK (03.04)© ABB 2004。

L-magBP 电磁流量计转换器 使用说明书

L-magBP 电磁流量计转换器 使用说明书
5.1 基本功能.................................................................................................................................. 18 5.2 特殊功能.................................................................................................................................. 19 5.3 正常工作条件.......................................................................................................................... 19 5.4 与传感器连接型式.................................................................................................................. 19 5.5 传感器配套要求...................................................................................................................... 19 5.6 整机测量精度..........................................................................................................................20 5.7 模拟电流输出..........................................................................................................................20 5.8 数字频率输出.......................................................................................................................... 20 5.9 数字脉冲输出.......................................................................................................................... 20 5.10 报警输出................................................................................................................................21 5.11 数字通讯接口及通讯协议....................................................................................................21 5.12 电气隔离................................................................................................................................21 5.13 数字量输出及计算................................................................................................................ 21 5.14 模拟量输出及计算................................................................................................................ 24

电磁流量阀MagnaValve说明书

电磁流量阀MagnaValve说明书

电磁流量阀MagnaValve说明书一、概述电磁流量阀MagnaValve是一种基于电磁感应原理的流量控制装置。

该阀门适用于液体介质的流量控制,能够准确、稳定地调节流量,并具备较高的自动化程度和远程控制能力。

本说明书将详细介绍该阀门的结构、工作原理、使用方法以及维护保养等方面的内容。

二、结构与工作原理1.结构电磁流量阀MagnaValve主要由阀体、阀芯、电磁阀、传感器、控制器等组成。

阀体是由优质不锈钢材料制成,具有很好的耐腐蚀性能。

阀芯采用先进的磁性材料制造,具有较强的磁力感应效果。

电磁阀是控制流量开关的关键部件,能够实现流量的调节和控制。

传感器可以实时感知流体的流量情况,并将数据传递给控制器进行处理。

2.工作原理当电磁阀通电时,电磁阀产生磁场,使阀芯受到磁力的作用而被吸引向阀体方向移动,导通流道。

液体在阀体内流动,经过传感器测量流速,并将流量数据传递给控制器。

控制器通过内置的控制程序进行数据处理,调整电磁阀的开启度,从而实现流量的控制。

当需要调节流量时,可以通过手动或远程方式调整控制器的参数,实现精确控制。

三、使用方法1.安装与连接(1)在安装前,请务必确认电源是否符合标准要求,并确保管道和阀门的连接正确牢固。

(2) 将电磁流量阀MagnaValve安装到管道上,确保阀体与管道连接紧密,并使用适当的密封材料进行密封。

(3)连接传感器和控制器,确保电路正常连接。

2.开机与校准(1)接通电源,开机前请检查电源和电路连接情况是否正常。

(2)按照说明书中的示例操作步骤进行校准,确保测量结果准确可靠。

3.流量调节(1)使用手动方式进行流量调节:根据实际需求,旋转控制器上的旋钮,逆时针旋转可增加流量,顺时针旋转可减少流量。

(2)使用远程方式进行流量调节:通过连接到控制器的计算机或终端设备,输入相应的指令进行流量调节。

确保远程控制设备和控制器连接稳定,指令传输的准确可靠。

四、维护保养1.定期检查与维护(1)定期检查电磁阀、阀体和管道是否有漏水或漏气现象,如有问题及时处理或更换零部件。

电磁流量计使用说明书共17页文档

电磁流量计使用说明书共17页文档

LDB型电磁流量计使用说明书1 产品用途与适用范围1.1 特点:■可编程频率低频矩形波励磁,提高了流量测量的稳定性,功率损耗低;■采用16位嵌入式微处理器,运算速度快。

精度高;■全数字量处理,抗干扰能力强,测量可靠,精度高,流量测量范围度可达1500 : 1;■超低EMI开关电源,适用电源电压变化范围大。

抗EMC性能好;■全汉字菜单操作,使用方便,操作简单,易学易懂;■高清晰度背光LCD显示;■具有双向流量测量、双向总量累计功能,电流、频率具备双向输出功能。

■内部具有三个积算器可分别显示正向累计量、反向累计量及差值积算量。

■具有RS485或RS232C数字通讯信号输出;■具有电导率测量功能,可以判别传感器是否空管;■具有自检与自诊断功能;■采用SMD器件和表面安装(SMT)技术,电路可靠性高;■仪表内部设计有不掉电时钟,可记录16次掉电时间。

1.2主要用途电磁流量计用来测量封闭管道中导电流体的体积流量。

广泛地适用于石油化工、钢铁冶金、给水排水、水利灌溉、水处理、环保污水总量控制、造纸、医药、食品等工、农业部门的生产工艺过程流量测量和控制;适用于导电液体的总量计量。

1.3正常工作条件环境温度:分体型–10~+ 60℃;相对湿度:5%~90%;供电电源:单相交流电85~265V,45~63Hz;功率:小于20W。

1.4 试验参比条件环境温度:20℃±2℃相对湿度:45%~85%电源电压:220±2% 电源频率:50Hz ±5% 谐波含量小于5%。

预热时间:30min2 产品型式电磁流量计有分体型和一体型两种结构形式。

3 工作原理电磁流量计的工作原理基于法拉第电磁感应定律。

当一个导体在磁场内运动,在与磁场方向、运动方向相互垂直方向的导体两端,会有感应电动势产生。

电动势的大小与导体运动速度和磁感应强度大小成正比。

在图1-1中,当导电流体以平均流速V (s m /)通过装有一对测量电极的一根内径为D (m )的绝缘管子流动时,并且该管子处于一个均匀的磁感应强度为B (T )的磁场中。

10系列电磁流量计简明操作手册

10系列电磁流量计简明操作手册

1200 48" 150 m3/h
– 54" 200 m3/h
1400 – 225 m3/h
– 60" 250m3/h
1600 – 300 m3/h
– 66" 325m3/h
1800 72"
– 78" 450 m3/h
2000 – 450m3/h
小流量切 除 (v ~ 0.04 m/s)
350 m3/h
按 进入菜单,按 键找到SIMULAT.SYSTEM(仿真系统),进入菜单SIM.MEASURAND(仿真测量),直接仿 真瞬时流量值,此时有电流输出和脉冲输出。仿真结束后,关闭仿真功能 输入密码:0010,也可以直接输入“10” ,当从左向右数第三个“*”号变成回车键后按“E”确认就可。
进入仿真系统菜单
375 15" 20 m3/h
400 16" 20m3/h
450 18" 25 m3/h
500 20" 30 m3/h
600 24" 40 m3/h
700 28" 50m3/h 30" 60 m3/h
800 32" 75m3/h
900 36" 100m3/h
1000 40" 125 m3/h
– 42" 125m3/h
9-300 25-700 35-1100 60-2000 90-3000 145-4700 Promag D
0.06-1.8 0.25 to 7 1-30 4-100 9-300 25-700 35-1100 60-2000 90-3000 145-4700 Promag H
Promag D

E+H 电磁流量计promag 10W中文说明书

E+H 电磁流量计promag 10W中文说明书

KA00032D/06/ZH/14.1171154561简明操作指南Proline Promag 10电磁流量测量系统6本《简明操作指南》不能替代供货范围中的《操作手册》。

详细信息请参考《操作手册》以及随附CD 上的其他文档。

完整的设备文档包括:•《简明操作指南》•与仪表型号相符的相关文档:–《操作手册》和《仪表功能描述》–防爆证书及安全证书–安装指南 — 与仪表型号相关(例如防爆证书、压力设备规程等)–其他相关信息Proline Promag 10目录1 安全指南. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.1 用途 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.2 安装、调试和操作 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.3 操作安全 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.4 安全图标 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 安装 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62.1 运往测量点 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62.2 安装条件 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72.3 Promag L传感器的安装 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122.4 Promag W传感器的安装 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172.5 Promag P传感器的安装 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232.6 Promag H传感器的安装 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272.7 变送器外壳的安装 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282.8 安装后检查 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303 接线 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313.1 不同外壳类型的仪表连接 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323.2 分体式仪表的电缆连接 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333.3 电势平衡 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363.4 防护等级 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 373.5 连接后检查 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374 调试 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384.1 开启测量设备 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384.2 运行 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394.3 浏览功能表 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 404.4 调试期间需设置的仪表功能 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414.5 故障检测 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 2Endress+HauserProline Promag 10安全指南1安全指南1.1用途•本测量设备仅用于测量密闭管道中导电介质的流量。

电磁流量转换器L magB系列中文PL

电磁流量转换器L magB系列中文PL

电磁流量计转换器使用说明书L- mag(B)系列(批量控制系列)2010年1月目录1. 产品功能说明 (1)1.1基本功能 (1)1.2特殊功能 (1)1.3正常工作条件 (1)1.4与传感器连接型式 (2)1.5安装尺寸图 (2)2. 转换器基本电路 (3)3. 技术性能指标 (5)3.1执行标准 (5)3.2基本参数与性能指标 (5)4. 转换器操作 (8)4.2转换器图 (9)4.3转换器接线图 (10)4.4连接电线电缆特性及连接要求 (12)4.5数字量输出及计算 (15)4.6模拟量输出及计算 (18)5. 仪表参数设置 (20)5.1L_M AG B四键转换器参数及操作 (20)5.2仪表详细参数说明 (25)6.红外手持遥控键盘 (32)7. 报警信息 (32)8. 故障处理 (33)8.1仪表无显示 (33)8.2励磁报警 (33)8.3空管报警 (33)8.4测量的流量不准确 (33)9. L_MAGB装箱与贮存 (34)9.1L_MAG B装箱 (34)9.2运输和贮存 (34)附录1励磁频率选择(参考) (35)附录2 拨码开关说明 (37)附录3 L_MAGB系列转换器HART功能说明 (38)附录4 流量系数修改记录功能 (39)附录5带非线性修正功能补充说明 (40)附录6 防雷功能说明 (41)附录7批量控制功能说明 (42)L_mag B型电磁流量计转换器使用说明书1. 产品功能说明1.1 基本功能■低频方波励磁,励磁频率:1/16工频、1/20工频、1/25工频;■高频方波励磁,励磁频率:1/2工频(适用于浆液测量)(选配);■励磁电流可选定为125mA、187.5mA、250mA;■无需附加电极的空管测量功能,连续测量,定值报警;■流速测量范围:0.1 --- 15米/秒,流速分辨率:0.5毫米/秒;■交流高频开关电源,电压适用范围:85V AC --- 250V AC;■直流24V开关电源,电压适用范围:20VDC --- 36VDC;■网络功能:MODBUS、HART(选配);■中文、英文显示方式,(可定制其它语言);■内部有三个积算器总量,可分别记录:正向总量、反向总量、差值总量。

MBmag型电磁流量转换器使用说明-2010版

MBmag型电磁流量转换器使用说明-2010版

MBmag型智能电磁流量转换器 使 用 说 明 书版本:2010在使用仪表前,请仔细阅读本说明书!目 录1 产品主要用途及特点 (1)1.1主要用途 (1)1.2特点 (1)1.3正常工作条件 (1)1.4试验参比条件 (1)2 产品型式及型号编码 (2)2.1 产品形式 (2)2.2 产品编码 (2)2.3外形及安装尺寸 (2)3工作原理 (3)4技术性能指标及操作 (4)4.1执行标准 (5)4.2 基本参数与性能指标 (5)4.3 键盘定义与显示 (6)4.4 安装及接线 (7)4.5 流量信号线 (11)4.6 励磁电流线 (12)4.7 电源线与输出信号线 (12)4.8数字通讯接口及接线 (15)4.9 接地 (18)4.10数字量输出 (18)4.11模拟量输出 (20)4.12接点控制输入 (21)5仪表参数设置 (21)5.1 键功能 (21)5.2 参数设置功能键操作 (21)6附加功能(选项)说明 (28)6.1 掉电计时功能 (28)6.2 定量控制功能 (28)6.3 红外遥控功能 (29)7自诊断信息与故障处理 (30)7.1 仪表无显示 (31)7.2 励磁报警 (31)7.3 空管与电极报警 (31)7.4 上限报警 (31)7.5 下限报警 ‥‥ (31)7.6 系统设置错误 (31)7.7 系统自检报警 (31)7.8 测量的流量不准确 (31)7.9 通讯故障检查 (31)8供应成套性 (32)9运输和贮存 (32)1产品主要用途及特点1.1主要用途MBmag型电磁流量转换器可以与不同型号的电磁流量传感器配套组成电磁流量计系统,用来进行测量封闭管道中导电流体的体积流量。

它们广泛地适用于石油化工、钢铁冶金、给水排水、水利灌溉、水处理、环保污水总量控制、造纸、医药、食品等工、农业部门的生产过程流量测量和控制;并适用于导电液体的总量计量与贸易交接。

1.2 特点:z频率可编程低频矩形波励磁,提高了流量测量的稳定性,功率损耗低;z采用新型含有FLASH存贮器的16位超低功耗微处理器,集成度高,运算速度快,计算精度高;z全数字量处理,抗干扰能力强,测量可靠;z超低EMI开关电源,适用电源电压变化范围大,效率高,温升小,EMC性能好;z中英文菜单操作,使用方便,操作简单,易学易懂;z高清晰度背光宽温型LCD显示;z能进行双向流量测量、双向总量累计。

SITRANS F M MAG 8000 电磁水表使用手册

SITRANS F M MAG 8000 电磁水表使用手册

电磁水表型号MAG 8000目录1.介绍1.1用户指南•和安全声明2.安装2.1机械安装流向入口和出口条件水平管上的安装垂直管上的安装大口径管上流量计的安装安装说明安装说明(接上页)电势平衡焊接与接地阴极保护管对需要将分离式传感器埋于地下时的建议最大允许扭矩最大允许扭矩(接上页)分体式安装标称尺寸PN 10PN 16 PN 40 Class 150mm inch Nm f/lbs Nm f/lbs Nm f/lbs Nm f/lbs 25 1“N/A N/A N/A N/A 10 7 7 5 40 11/2“ N/A N/A N/A N/A 16 12 9 7 50 2“N/A N/A 25 18 N/A N/A 25 18 65 21/2“ N/A N/A 25 18 N/A N/A 25 18 80 3“N/A N/A 25 18 N/A N/A 34 25 100 4“ N/A N/A 25 18 N/A N/A 26 19 125 5“ N/A N/A 29 21 N/A N/A 42 31 150 6“ N/A N/A 50 37 N/A N/A 57 42 200 8“ 50 37 50 37 N/A N/A 88 65 250 10“ 50 37 82 61 N/A N/A 99 73 300 12“ 57 42 111 82 N/A N/A 132 97 350 14“ 60 44 120 89 N/A N/A 225 166 400 16“ 88 65 170 125 N/A N/A 210 155 450 18“ 92 68 170 125 N/A N/A 220 162 500 20“ 103 76 230 170 N/A N/A 200 148 600 24“ 161 119 350 258 N/A N/A 280 207检查传感器和变送器的序列号,确保两者相匹配(1)。

史密斯立磨电磁流量计

史密斯立磨电磁流量计

电磁流量计传感器型号MAG 1100和MAG 3100信号变换器型号MAG 5000和MAG 6000目录1. 传感器的安装 (3)2. 信号变换器的安装 (4)2.1 紧凑安装。

紧密聚酰胺。

(4)2.2.1 远距离安装 (5)2.2.2 远距离安装 (6)2.3.3 远距离安装 (7)3. 技术数据 (8)3.1 信号变换器MAG 5000和MAG 6000 (8)4. 电源接线 (10)4.1 信号变换器MAG 5000和MAG 6000 (10)4.2 MAG 5000和MAG 6000输出特性 (11)5. 调试 (12)5.1 菜单概观 (12)5.2 菜单详述 (13)5.3 菜单详述(输出) (14)6.2 检修MAG 5000和MAG 6000 (15)1. 传感器的安装在水平管内安装必须如上图所示安装传感器。

不要像下图那样安装传感器。

这样可以把电极定位在有气泡的顶部以及可能有泥巴、淤积物、沙子等的底部。

如果是空管探测,可以如上所示把传感器倾斜45°。

测量磨蚀液和包含小颗粒的液体。

我们建议您安装在一个竖管或斜管中以减轻传感器磨损和沉淀。

进口和出口条件为了测量精确,进口和出口管要笔直,泵和阀之间要有一定距离。

把流量计置于管子法兰和垫片的中心也很重要。

电位均衡液体的电位必须和传感器的电位相等。

可以根据应用采用不同的方法实现这一条件:A. 在传感器和邻近的法兰之间连接跳线(MAG 1100和MAG 3100)。

B. 在传感器和配件之间的直接金属接触(MAG 1100 FOOD )。

C. 内置接地电极(MAG 3100和MAG 3100w )。

D. 可选接地/保护法兰/环(MAG 1100和MAG 3100)。

E. MAG 1100上的可选石墨垫片(MAG 1100高温标准)。

2. 信号变换器的安装2.1 紧凑安装。

紧密聚酰胺。

拆除并丢弃传感器的接线盒盖。

电源电缆和输出电缆装配PG 13.5电缆夹套。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

MBmag型智能电磁流量转换器 使 用 说 明 书版本:2010在使用仪表前,请仔细阅读本说明书!目 录1 产品主要用途及特点 (1)1.1主要用途 (1)1.2特点 (1)1.3正常工作条件 (1)1.4试验参比条件 (1)2 产品型式及型号编码 (2)2.1 产品形式 (2)2.2 产品编码 (2)2.3外形及安装尺寸 (2)3工作原理 (3)4技术性能指标及操作 (4)4.1执行标准 (5)4.2 基本参数与性能指标 (5)4.3 键盘定义与显示 (6)4.4 安装及接线 (7)4.5 流量信号线 (11)4.6 励磁电流线 (12)4.7 电源线与输出信号线 (12)4.8数字通讯接口及接线 (15)4.9 接地 (18)4.10数字量输出 (18)4.11模拟量输出 (20)4.12接点控制输入 (21)5仪表参数设置 (21)5.1 键功能 (21)5.2 参数设置功能键操作 (21)6附加功能(选项)说明 (28)6.1 掉电计时功能 (28)6.2 定量控制功能 (28)6.3 红外遥控功能 (29)7自诊断信息与故障处理 (30)7.1 仪表无显示 (31)7.2 励磁报警 (31)7.3 空管与电极报警 (31)7.4 上限报警 (31)7.5 下限报警 ‥‥ (31)7.6 系统设置错误 (31)7.7 系统自检报警 (31)7.8 测量的流量不准确 (31)7.9 通讯故障检查 (31)8供应成套性 (32)9运输和贮存 (32)1产品主要用途及特点1.1主要用途MBmag型电磁流量转换器可以与不同型号的电磁流量传感器配套组成电磁流量计系统,用来进行测量封闭管道中导电流体的体积流量。

它们广泛地适用于石油化工、钢铁冶金、给水排水、水利灌溉、水处理、环保污水总量控制、造纸、医药、食品等工、农业部门的生产过程流量测量和控制;并适用于导电液体的总量计量与贸易交接。

1.2 特点:z频率可编程低频矩形波励磁,提高了流量测量的稳定性,功率损耗低;z采用新型含有FLASH存贮器的16位超低功耗微处理器,集成度高,运算速度快,计算精度高;z全数字量处理,抗干扰能力强,测量可靠;z超低EMI开关电源,适用电源电压变化范围大,效率高,温升小,EMC性能好;z中英文菜单操作,使用方便,操作简单,易学易懂;z高清晰度背光宽温型LCD显示;z能进行双向流量测量、双向总量累计。

具有量程自动切换功能,更有效地提高了模拟电流和频率输出的测量精度,特别适用于昼夜流量范围变化大并需要发出控制信号的场合。

流量测量范围度可达1500:1。

z内部有三个积算器,分别记录和显示正向累计量、反向累计量及累计差值积算量,方便于流体计量和贸易交接。

z提供隔离或非隔离RS485/RS232C数字通讯接口,并支持MODBUS、PROFIBUS-DP及HART等现场总线通讯方式;z采用恒流源流体电阻测量,可以在长线传输的情况下,准确测量电极信号内阻。

不仅可用来判别传感器内流体是否空管,而且能够判别电极被污染、覆盖等异常现象,为用户提供清洗电极等故障处理信息;z使用智能化判断,不采用测量修正设置,空管报警与电极检测应用更加便捷。

z先进的“粗大误差处理”技术,能够切除浆液等流体测量尖状干扰,减小输出跳动,保持高精度测量并使输出更加稳定;z具有流体密度设置,可以显示质量流量;z恒流励磁电流范围大,可与不同制造商、不同类型的电磁流量传感器配套使用;z具有积算器远程清零的控制功能,具有开启与停止累计的接点信号输入,适于总量检验和批量处理应用;z具有自检与自诊断功能;z采用先进的非易失性存贮器,电路可靠性更高,有效地保护设置和测量参数;z仪表可选配不掉电时钟及存储器,用于记录掉电时间、上电时间及掉电时刻的流量。

z仪表带有可选小时记录功能,可保存30天以上历史的流量和电极电阻测量值。

z新的键盘处理方式,避免键盘操作影响测量。

可以进、退位操作菜单,使参数设置更加便捷。

z总量显示采用10位十进制9999999999满值进位,解决了双字型满值4294967285(十六进制数FFFF)进位不合习惯的做法。

1.3 正常工作条件环境温度: –10~+ 55℃;相对湿度:5%~90%;供电电源:单相交流电 85~265V,45~63Hz;直流电16~30V;功 率:与传感器配套,小于15W。

1.4 试验参比条件环境温度:20℃±2℃相对湿度:45%~85%电源电压:220±2%电源频率:50Hz±5%谐波含量小于5%。

预热时间:30min2产品型式及型号编码2.1 产品形式MBmag型电磁流量转换器与传感器配套,按外形结构形式可分为:与传感器组成一体的一体型和分离安装的分体型两种。

2.2 产品编码MBmag型电磁流量转换器产品编码如下表所示:MBmag电磁流量计转换器产品型号编码表。

编码举例:1、型号MBmag-CAL402T即为:一体型、220V供电、低频、带485通讯、无外壳、250mA励磁、带掉电计时功能。

2、型号MBmag-RDH412T即为:分体型、24V供电、高频、带485通讯、有外壳、250mA励磁、带掉电计时功能。

用户如有特殊要求,请与我们及时联系!2.3外形及安装尺寸分体型转换器外形图 一体型转换器外型图 3工作原理电磁流量计的工作原理是基于法拉第电磁感应定律。

当导体在磁场内运动,在与磁场方向、运动方向相互垂直方向的导体两端,会有感应电动势产生。

电动势的大小与导体运动速度和磁感应强度大小成正比。

在图3.1中,当导电流体以平均流速V (sm/),通过装有一对测量电极的一根内径为D(m)的绝缘管子流动时,并且该管子处于一个均匀的磁感应强度为B(T)的磁场中。

那么,在这对电极上就会感应出垂直于磁场和流动方向的电动势(E)。

由电磁感应定律,E可写作(1)式:VDkBE⋅⋅=(V) (1)式中k是比例系数。

U图3.1 电磁流量计工作原理通常,体积流量可以写作V D q v 42π=(s m /3) (2)由公式(1)和(2)可得到:)(43s m BE k D q v π= (3)因此电动势可表示为:)(q 4v V DkBE π=………………………(4) 当B 是个常数时,公式(3)中A Bk D =14π,公式(3)改写为:)/(3s m AE q v = (5)可见,流量v q 与电动势E 成正比。

图3.2 转换器电路结构转换器一方面向传感器励磁线圈提供恒定的励磁电流,以保证磁感应强度B 是个常量;同时把传感器电极感应的电动势放大转换成标准的电流信号或频率信号,便于流量的显示、累计、控制与调节。

图3.2所示为转换器电路结构。

4技术性能指标及操作4.1 执行标准GB/T 18660-2002 电磁流量计的使用方法。

GB/T 18659-2002 电磁流量计的性能评定。

Q/SHQ-2005 MBmag-2005电磁流量转换器企业标准。

4.2 基本参数与性能指标4.2.1 配套传感器公称通径:3、6、10、15、20、25、32、40、50、65、80、100、125、150、200、250、300、350、400、450、500、600、700、800、900、1000、1100、1200、1300、1400、1600、1800、2000、2200、2400、2600、2800、3000;4.2.2 流量测量范围MBmag型电磁流量转换器与传感器配套,流量测量范围上限值的流速可在0.3m/s~15m/s范围内选定,下限值的流速可为上限值的1%。

4.2.3 参比条件下转换器的精确度等级为0.2级。

对应的基本误差限在量程的10%以上为示值的±0.2%(±0.2%R);在量程的10%以下为量程的±0.2%(±0.2%FS)。

4.2.4 重复性误差不超过基本误差限绝对值的二分之一。

4.2.5 电流输出a)电流输出信号:全隔离0~10mA / 4~20mA。

b)负载电阻:0~10mA时,0~1.5kΩ;4~20mA时,0~750Ω。

C) 基本误差:在上述测量基本误差基础上加±10μA。

4.2.6 频率输出频率输出:输出频率上限可在1~5000Hz内设定。

频率输出为带光电隔离的晶体管集电极开路输出。

外接电源不大于35V,导通时集电极最大电流为50mA。

4.2.7 脉冲输出脉冲输出:输出脉冲上限可达5000cp/s。

脉冲当量定义为每个脉冲代表的体积流量。

脉冲当量可以选择0.0001L/p、0.001L/p、0.01L/p、0.1L/p、1.0L/p、2L/p、5L/p、10L/p、100L/p、1m3/p、10m3/p、100 m3/p和1000 m3/p。

脉冲宽度可以选择:自动、10ms、20ms、50ms、100ms、150ms、200ms、250ms、300ms、350ms和400ms。

脉冲输出为带光电隔离的晶体管集电极开路输出。

外接电源不大于35V,导通时集电极最大电流为50mA。

4.2.8 流向指示/量程指示输出本流量计可测正反方向的流体流动流量,并可以判断出流体流动的方向。

该输出为带光电隔离的晶体管集电极开路报警输出。

外接电源不大于35V,导通时集电极最大电流为50mA。

若使用内部+12V供电,则规定显示正向流量时输出0V低电平,反向流体流动输出+12V的高电平。

在自动双量程切换应用中,第一量程(高量程)输出0V低电平,第二量程(低量程)输出+12V高电平。

4.2.9 报警输出:两路带光电隔离的晶体管集电极开路报警输出。

外接电源不大于35V,导通时集电极最大电流为50mA。

报警状态:流量上限报警、下限报警。

4.2.10 串行通讯:标准配置非隔离型RS232C或RS485串行通讯接口,可选配全隔离型RS232C或RS485通讯接口,支持RTU格式MODBUS协议及Profibus-DP通讯协议。

4.2.11 测量阻尼时间:在0~100s时间分档可选。

4.2.12 电气隔离:模拟输入与模拟输出间绝缘电压不低于500V;模拟输入与报警电源间绝缘电压不低于500V;模拟输入与交流电源间绝缘电压不低于500V;模拟输出与交流电源间绝缘电压不低于500V;模拟输出与大地之间绝缘电压不低于500V;脉冲输出与交流电源间绝缘电压不低于500V;脉冲输出与大地间绝缘电压不低于500V;报警输出与交流电源间绝缘电压不低于500V;报警输出与大地间绝缘电压不低于500V。

4.2.13 接点输入外部接点ON(接通)或OFF(断开)信号能够远程控制转换器内部计数器累计流量的开始与停止。

也能够起到远程清零计数器。

4.2.14 外壳防护等级:IP654.3 键盘定义与显示图4.1(a)方型分体转换器键盘定义与液晶显示图4.1(b)圆型一体转换器键盘定义与液晶显示状态。

相关文档
最新文档