5种床旁检测法与Abbott化学发光法检测心肌标志物的对比研究

合集下载

雅培心脏标志物

雅培心脏标志物

AMI临界值
建议连续抽血化验以观测肌钙蛋白I水平,其值是否符合AMI特征随时间升高和降低的规律, 连续抽血化验的结果应当结合其他信息做出判断,例如其他心脏标志物、ECG、临床症状等。
9
第99百分位点及10%CV Assay Performance: Currently, Assay values are independent of each other and NOT standardized
AxSYM
Architect 2000
2
动脉斑块
随着动脉内的斑块越来越大,管腔变窄,血管内通过的血流量越来 越少。
正常动脉
动脉粥样硬化导致 动脉官腔变窄
血流
斑块
3
冠状动脉疾病(Coronary Artery Disease, CAD)
冠状动脉
斑块
放大的冠状动脉示意图
4
心血管疾病与标志物
Cardiac Risk
Thrombosis
ACS*/ MI**
Heart Failure
Homocysteine CRP
Homocysteine
Troponin CK-MB Myoglobin
BNP
5
心脏守护者 – 肌钙蛋白I
肌钙蛋白I
• 特异性最好的心脏损伤标志物
• 有助于心肌梗死的早期诊断
• 对标本采集和处理技术比较敏感
• 检测心脏生物标志物应当争取使第99百分位参考限值的总的不精密度 (%CV)<10%。
1. Morrow DA, et al. Clin Chem. 2007;53:4:552-574.
20
2007 NACB发表的建议
“已经形成的专家共识支持用第99百分位值作为参考临界值,无论所用检 测方法总的不精密度是否 <10%。”

血检四项化学发光法调查

血检四项化学发光法调查

血检四项化学发光法调查目前血检四项(HBsAg、HCV、HIV、TP)的检测方法主要有酶联免疫(ELISA)、核酸扩增(PCR)、胶体金标记、以及化学发光(CLIA)。

现就CLIA在血检项目中的应用情况做一调查分析。

一.化学发光免疫分析法简介。

化学发光免疫分析法(Chemiluminescence imnunoassay,CLIA)是建立在放射免疫分析技术(radioimmunoassay,RIA)理论的基础上,以标记发光剂为示踪物信号建立起来的一种非放射标记免疫分析法。

CLIA是利用化学反应中释放大量自由能,产生激发态中间体,当其回到稳定的基态时发射出光子(hν),用发光信号测量仪对所发出的光量子进行定量测量。

鲁米诺(1umino1)、异鲁米诺(isolumino1)及其衍生物、吖啶酯(acIidinim ester)衍生物、辣根过氧化物酶(horseradishperoxidase,HRP)和碱性磷酸酶(alkaline phosphatase,ALP)是目前CLIA中使用最多的四类标记物。

表1 化学发光法类型注:* 严格意义上属于荧光免疫。

二.国内外化学发光法的仪器和试剂情况。

国外化学发光法检测仪器的生产厂家以贝克曼、雅培、罗氏、拜耳这四家的市场占有率较高。

其中罗氏拥有唯一的电化学发光技术,雅培则独占微粒子酶联免疫(EMIA)。

不同厂家的仪器有各自的优势检测项目,主流的仪器型号如下:表2 国外主要化学发光免疫分析仪厂家国内也逐渐有厂家研制化学发光试剂,配合国外引进的仪器(多为半自动)共同销售,也有自发研制的化学发光仪(泰格科信)。

针对血检四项(HBsAg、HCV、HIV、TP),除北京科美生物(科美东雅)外,所有厂家试剂均只有HBsAg试剂。

表3 国内主要厂家仪器和试剂情况国外厂家的试剂大多随仪器配送,并没有在SFDA单独注册。

目前SFDA注册的血检四项化学发光法试剂列表如下。

就检测项目来看,除梅毒外,其余三项均可使用化学发光法;就现有资料,国内外只有北京科美东雅配有梅毒检测试剂。

POCT的急诊应用20121124

POCT的急诊应用20121124
“不在中央检验室而在病人身边进行的检验,其 结果可改进病人的医疗措施”;
由临床实验室制订的,但不在检验科设施中对病 人进行的测定,不需要固定、专用的场所;
将试剂盒和设备一起手携或运送到病人身边
心血管标记物检测的 急诊临床策略
首都医科大学宣武医院急诊科
POCT Point of Care Testing
目前尚无规范的中文对应词,一般翻译为“床旁检测”。 国外曾有不少与POCT相关的名词,如 : bedside testing(床边检测)、 near-patient testing(病人身边检测)、 physicians`office testing(医师诊所检验)、 home use testing(家用检验) extra-laboratory testing(检验科外的检验) decentralized testing(分散检验) 随着这一领域的不断发展,这些名词都已不能概括POCT
AUC 0.996 0.996
95% CI 0.991 - 1.000 0.991 – 1.000
临床灵敏度
(95% CI)
临床特异性
(95% CI)
PATHFAST
同步6个通道,样本和项目均可任意组合 精确全定量:cTnI,Myo,CK-MB,NTproBNP,D-Dimer,
hs-CRP
17分钟完成6个测试 全血,血浆样本 操作简便 与LIS系统双向联网
制造商:三菱化学美迪恩斯株式会社
PATHFAST®
PATHFAST® cTnI定量分析的精密度评估
True positive rate (Sensitivity)
1
0.8
0.6
0.4

一文解读罗氏、雅培、贝克曼、西门子、梅里埃等8大国际巨头化学发光篇!

一文解读罗氏、雅培、贝克曼、西门子、梅里埃等8大国际巨头化学发光篇!

⼀⽂解读罗⽒、雅培、贝克曼、西门⼦、梅⾥埃等8⼤国际巨头化学发光篇!4. 化学发光跨国巨头的沧海桑⽥跨国巨头的发光产品从21世纪初进⼊中国,四⼤家(RABS)以不同的节奏进⼊中国,2003年西门⼦最早进⼊中国市场,随后贝克曼,雅培等企业纷⾄沓来,2006年罗⽒的电化学发光进⼊中国,进⼝品牌迅速扩张领⼟。

注:以上数据以拿到CFDA注册证为依据2003-2013,短短的10年时间,化学发光的市场容量到达百亿,随着可检测项⽬的逐步丰富和开发,发光市场仍然以2年翻⼀倍的速度在不断扩张。

化学发光在全球体外诊断细分中增速保持前三,⽽从地理区域的维度来看,中国是发展最为迅速的市场,2011-2016年复合增速为30%,RABS的年度报告中都可以看到,中国区域成为了增长区域最快的市场,未来3年仍将处于⾼速发展中。

由于化学发光的多品牌并⾏现象,各⼤品牌都能保持很⾼的增速。

2011-2016年期间,进⼝品牌都保持25%以上的复合增速,未来3年也将保持20-15%的平均增速。

4.1. 罗⽒(Roche)综合实⼒强劲,稳居IVD头把交椅罗⽒1896 年于瑞⼠成⽴,2015年罗⽒全球475亿美⾦,药品占78%,诊断占22%。

罗⽒优秀的产品和积极的销售策略,使得他各条产品线表现都⾮常优秀,综合实⼒在体外诊断领域排全球第⼀。

免疫领域,罗⽒以电化学发光为其核⼼产品,该产品是由宝灵曼1996年研发⽽成,具有核⼼专利保护,被称为第四代化学发光。

罗⽒公司1997年收购宝灵曼公司后,产品不断升级换代,⽬前以170 T/H的E170和86T/H的E411为主要产品。

2016年罗⽒电化学发光专利正式过期。

⽬前罗⽒化学发光项⽬共有105个,项⽬范围涵盖齐全,包括甲状腺功能、激素、过敏、唐⽒综合征、糖尿病、贫⾎、先兆⼦痫、肿瘤标志物、⼼肌标志物、浓毒⾎症、移植药物、传染性疾病、传染性疾病、⾻标志物和⾃⾝免疫等15⼤类菜单。

罗⽒拳头套餐为肿瘤标志物,其菜单也在不断的完善中,市场推⼴以学术推⼴为主要风格、样本量达到⼀定数量的医院⼚家派⼈驻点直销,由于罗⽒除了诊断产品,还有药品和病理产品,所以在临床的推⼴可以⼀体化推⼴。

雅培化学发光仪器介绍

雅培化学发光仪器介绍

雅培化学发光仪器介绍雅培化学发光仪器介绍雅培(Abbott) AxSYM雅培(Abbott)公司Axsym全自动微粒子酶免疫化学发光仪是集微粒子酶免分析技术(MEIA)、离子捕获免疫分析技术(ICIA)、荧光偏振免疫分析仪技术(FPLA)三种先进技术于一体的先进仪器,不同方法的结合使用,扩大了检测范围,并可根据不同被检测物的特点设计不同的反应步骤,具有灵敏度高、线性范围宽、检测速度快及检测项目齐全等特点。

Axsym(雅培化学发光仪)简易维修手册全自动化学发光免疫分析仪(雅培Axsym)操作雅培化学发光仪器介绍全自动化学发光免疫分析仪(雅培Axsym)操作雅培化学发光仪器介绍Axsym(雅培化学发光仪)简易维修手册美国雅培i2022年化学发光法雅培化学发光仪器介绍发光免疫分析法是将发光反应与免疫反应相结合而产生的一种免疫分析法。

我科引进美国雅培i-2022年全自动化学发光免疫分析仪,同时可检测25项,每小时200个测试,提高工作效率和检测的准确度与灵敏度,减少人为操作误差。

该仪器采用智能化分步冲洗,使用磷酸盐缓冲液和表面活性剂,彻底消除试验携带问题,提高了测试结果的可信度。

通过压力检测的凝块检测技术可确保样本的前处理质量。

化学发光免疫分析(CLIA)检测原理:是一种以发光物质代替放射性核素或酶作为标记物直接标记抗体或抗原的一类免疫分析法。

常用的发光剂为丫啶酯类。

这类标记物在化学结构上有产生发光的特殊基团,在发光免疫分析过程中直接参与发光反应。

这类物质没有本底发光,在反应中能用于检测低浓度或微量浓度的样品。

干扰作用也较少且标记和偶联后稳定、理化性质和免疫特性不改变。

是一类发光效率很高的发光剂。

可与抗体(或抗原)结合,生成具有化学发光活性强,免疫反应特异性高的标记抗体。

检测技术中检测小分子抗原使用竞争法;检测大分子抗原用夹心法。

诊断试剂盒:已开发的诊断试剂盒主要有病毒标志物类、内分泌激素类、肿瘤标志物类、心肌标志物类、治疗性药物浓度、骨代谢指标和贫血类等方面的指标。

雅培化学发光仪器介绍

雅培化学发光仪器介绍

雅培(Abbott) AxSYM雅培(Abbott)公司Axsym全自动微粒子酶免疫化学发光仪是集微粒子酶免分析技术(MEIA)、离子捕获免疫分析技术(ICIA)、荧光偏振免疫分析仪技术(FPLA)三种先进技术于一体的先进仪器,不同方法的结合使用,扩大了检测范围,并可根据不同被检测物的特点设计不同的反应步骤,具有灵敏度高、线性范围宽、检测速度快及检测项目齐全等特点。

Axsym(雅培化学发光仪)简易维修手册/p-6661637955883.html全自动化学发光免疫分析仪(雅培Axsym)操作/p-7803709690226.html全自动化学发光免疫分析仪(雅培Axsym)操作美国雅培i2000化学发光法发光免疫分析法是将发光反应与免疫反应相结合而产生的一种免疫分析法。

我科引进美国雅培i-2000全自动化学发光免疫分析仪,同时可检测25项,每小时200个测试,提高工作效率和检测的准确度与灵敏度,减少人为操作误差。

该仪器采用智能化分步冲洗,使用磷酸盐缓冲液和表面活性剂,彻底消除试验携带问题,提高了测试结果的可信度。

通过压力检测的凝块检测技术可确保样本的前处理质量。

化学发光免疫分析(CLIA)检测原理:是一种以发光物质代替放射性核素或酶作为标记物直接标记抗体或抗原的一类免疫分析法。

常用的发光剂为丫啶酯类。

这类标记物在化学结构上有产生发光的特殊基团,在发光免疫分析过程中直接参与发光反应。

这类物质没有本底发光,在反应中能用于检测低浓度或微量浓度的样品。

干扰作用也较少且标记和偶联后稳定、理化性质和免疫特性不改变。

是一类发光效率很高的发光剂。

可与抗体(或抗原)结合,生成具有化学发光活性强,免疫反应特异性高的标记抗体。

检测技术中检测小分子抗原使用竞争法;检测大分子抗原用夹心法。

诊断试剂盒:已开发的诊断试剂盒主要有病毒标志物类、内分泌激素类、肿瘤标志物类、心肌标志物类、治疗性药物浓度、骨代谢指标和贫血类等方面的指标。

化学发光法与免疫比浊法检测心肌肌钙蛋白的比较

化学发光法与免疫比浊法检测心肌肌钙蛋白的比较

比, 化 学 发 光 法检 测 结 果 与 临床 诊 断 的 符 合 率 达 到 9 9 , 而比浊法的只有 5 9 % 。结 论 化 学 发 光 法检 测 c T n I 明 显
优 于免 疫 比 浊 法 。
【 关 键 词】 心 肌 肌 钙 蛋 白检 测 ; 化 学发 光 法 ; 免 疫 比 浊 法 ; 比较
D o I : 1 0 . 3 9 6 9 / j . i s s n . 1 6 7 2 - 9 4 5 5 . 2 0 1 3 . 0 3 . 0 6 0 文 献标 志 码 : B 文章编号 : 1 6 7 2 - 9 4 5 5 ( 2 0 1 3 ) 0 3 — 0 3 5 6 - 0 2
1 材 料 与 方 法
消退 , 睑缘 正 好 处 于 角 膜缘 下 1 ~2 mm , 术 后 做 下 睑 牵 引 线 闭
[ 2 ] 林明 , 李瑾, 朱惠敏 , 等. 改 良额 肌 筋 膜 瓣 悬 吊术 矫 治 重 度 上 睑 下 垂 的临 床 疗 效 观 察 E J ] . 眼科 , 2 0 0 8 , 7 ( 6 ) : 3 8 2 — 3 8 5 . E 3 1 徐乃 江 , 朱 惠敏 , 杨 丽. 实 用 眼整形 美 容手 术学 [ M] . 郑
州: 郑州大学出版社 , 2 0 0 3 : 1 3 8 — 1 4 2 .
合睑裂 , 术 眼 加压 包 扎 。 ( 2 ) 矫正不足一般手术后 3 ~6 个 月 再
次缩短 ; 矫 正 过度 : 轻者采 用上 睑向下加压 按摩 , 多数 可恢 复,
[ 4 ] 黄红波 , 陈光胜 , 马丽华. 治疗 3 1例 上 睑 下 垂 的 疗 效 观 察 E J ] . 柳 州 医学 , 2 0 0 7 , 2 0 ( 4 ) : 2 6 5 — 2 6 6 . [ 5 3 周 业 文. 提 上 睑肌 缩 短 术 式 应 用 探 讨 E J ] . 中 国水 电 医 学 ,

胶体金免疫层析法与化学发光法在心肌梗死诊断中的价值比较

胶体金免疫层析法与化学发光法在心肌梗死诊断中的价值比较

胶体金免疫层析法与化学发光法在心肌梗死诊断中的价值比较梁玉庚孙笑菊武飞飞侯喜1 夏志星2【摘要】〔摘要〕目的比较胶体金免疫层析法与化学发光法检测心肌标志物在诊断心肌梗死(MI)中的应用价值。

方法收集MI住院患者98例,采用化学发光法与胶体金免疫层析法检测患者心肌标志物肌钙蛋白(cTn)I、肌红蛋白(Mb)、肌酸激酶同工酶(CK-MB)水平,计算胶体金免疫层析法灵敏度、特异度、阳性预测值、阴性预测值、正确指数。

结果胶体金免疫层析法与化学发光法相关性分析,cTnI、Mb、CK-MB的相关系数依次为0.607、0.647、0.481(Plt;0.05)。

cTnI、Mb、CK-MB阳性率在两种检测方法中无统计学差异(Pgt;0.05)。

胶体金免疫层析法检测cTnI、Mb、CK-MB灵敏度依次为88.16%、88.41%、83.78%,特异度依次为77.27%、79.31%、66.67%。

结论胶体金免疫层析法检测心肌标志物方便快捷,灵敏度高。

【期刊名称】中国老年学杂志【年(卷),期】2017(037)022【总页数】2【关键词】〔关键词〕胶体金免疫层析法;化学发光法;心肌标志物;心肌梗死心肌梗死(MI)是由于长时间缺血导致的心肌细胞坏死〔1〕,心肌细胞膜损害造成各种蛋白如肌红蛋白(Mb)、肌钙蛋白(cTn)I和cTnT、肌酸激酶同工酶(CK-MB)水平增高〔2,3〕。

这些生化指标可反映心肌损伤状态,通常在专业的中心实验室或检验科采用生化分析和免疫分析进行检测〔4〕。

为了可以更早更方便地对MI进行筛查和诊断从而达到早发现早治疗的二级预防目的,以胶体金免疫层析法为代表的即时检测方法得到关注。

本文比较胶体金免疫层析法与化学发光法检测心肌标志物在MI诊断中的应用价值。

1 资料与方法1.1 一般资料收集2012年1月至2013年12月石家庄长城中西医结合医院收治的MI住院患者98例,男67例,女31例;年龄36~82〔平均(62.24±14.14)〕岁。

国产化学发光乙肝五项定量检测试剂盒与雅培试剂对照及临床应用价值探讨

国产化学发光乙肝五项定量检测试剂盒与雅培试剂对照及临床应用价值探讨
·110·
医药论坛杂志 2009年 10月 第 30卷 第 20期
以通过耐药菌株的传播而完成 。 药敏结果显示 ,产 ESBL s的菌株与非产 ESBL s
的菌株耐药差异很大 ,提示在应用抗生素进行治 疗时 ,应该根据是否产 ESBL s的特点来选择药物 。 治疗产 ESBL s的大肠埃希菌 ,碳氢霉希类 、含酶抑 制剂的 beta - 内酰胺类抗生素及阿米卡星具有非 常高的敏感率 ,这一结果与其他地区的报道一致 。
另外 ,乙肝疾病的发生 、发展 、疗效 、预后是一 个动态的变化的过程 ,化学发光定量检测乙肝五 项各项血清学标志物的浓度变化及联合检测结果 分析可对乙肝的病程 、治疗 、预后起一个全程动态 监测的作用 ,能够为临床医生对病情疗效作出合 理的解释提供依据 ,以进一步指导治疗 。另外高 灵敏度 、宽线性范围的乙型肝炎病毒标志物定量 检测产品联合检测对急性乙肝和慢性无症状携带 者转归分析起到较大的动态监测作用 ,可以减少 漏检和假阳性结果 ,并且结合抗 - HB s浓度的定量 分析可以用于评估注射乙肝疫苗后免疫效果 ,对 乙肝疫苗免疫力的评价和高危人群预防免疫具有 重要意义 ,特别是在少年儿童预防乙肝方面 [ 7 ] 。
Journal of M edical Forum Vol130 No120 October 2009
·111·
~3为阴性 。 ②化学发光检测仪 (Lumo) 、洗板机 ( iWO )及配套试剂 (批号为 20080402)由郑州安图 生物工程有限公司提供 ,安图生物试剂检测乙肝 五项的线性范围如下 : HB sAg: 011 ~180ng /m l 抗 - HB s: 0~1000U /L HBeAg: 0125~100 NCU /m l抗 - HB e: 1 ~30 NCU /m l 抗 - HB c: 2 ~60 NCU /m l; 正常 值 范 围 : HB sAg: < 0115ng /m l 抗 - HB s: < 10U /L HB eAg: < 0125 NCU /m l 抗 - HB e: < 3 NCU /m l抗 - HB c: < 3 NCU /m l。 ③科华和新创的 生产乙型肝炎病毒 e抗体酶联免疫诊断试剂盒 。 113 方法 ①严格按照试剂盒说明书操作和判定 结果 。 ②检测 HB sAg、抗 - HB s 、HBeAg、抗 - HB e 和抗 - HBc指标的血清样品共 167人份 ,为患者标 本 ,均用 Abbott Axsym 和郑州安图生物两种试剂 检测 ,抗 - HBc均采用原倍血清检测 。

探讨化学发光法同放射免疫法检测血清心肌酶的效果

探讨化学发光法同放射免疫法检测血清心肌酶的效果

0 引言
化学发 光法是 近年来 新发展起来 的的检验手段 ,具有 检 测便捷 、灵敏 度高 、重 复性好及 试剂安 全无毒 的特点 ,占领 了医疗 市 场 ,广 泛用 于 激 素 、酶类 等 指标 的临床 检 测 。放 射 免疫 法 是 临床 检 测微 量 物质 的 重要 手 段 ,临床 应 用 时 间 较长, 检验效 果 比较稳 定 。为进一步 了解化 学发光法 的特点 ,
结果 化学发 光法测得血 清肌酸激酶浓度为 ( 1 7 0 . 4±1 9 . 8 ) n g / ml ,放射免疫法测得血 清肌酸激酶浓度为 ( 1 6 4 . 2 ±2 0 . 1 ) n g / ml ,经比较二 者差异无统计学意义 ( P >0 . 0 5);两种方法均具有 良好 的线性 关 系,但化 学发 光法的线性范 围较放 射免疫 法宽。且化学发光法的重复性好 于放射免疫法 。结论 化学发光法同放射免疫 法检测心肌酶谱 能够取得相似的检 验 效果 ,但化 学发光法具有更好的精 密度 。 关键词 :化 学发光法 ;放射免疫法 ;心肌酶 中 图分 类号 :R 4 4 6 文 献标 识 码 :B DO I :1 0 . 3 9 6 9 / j . i s s n . 1 6 7 1 - 3 1 4 1 . 2 0 1 3 . 1 7 . 1 6 1
3 讨 论
放 射免疫 法是检测 肌酸激 酶的经典 方法 ,原理在 于 同时
将 以放 射性 同位 素 标记 的抗原 与 未标 记 的抗 原 结合 特 异性 抗体 ,使 其 产 生可 逆性 竞 争反 应 ,进 而检 测 抗 原 和抗 体 的 含量 [ 1 1 。放射 免疫法 的优点是 试剂成 本低 ,检测结 果精确性 比较高 ,缺 点 是耗 时 较 长 ,常 不 能满 足 临 床快 速诊 断 的需 要 ; 碘1 2 5等 同位 素具 有 放射 性 ,对 工作 人 员 和 环境 都 会 产 生放 射 性 污染 ;而且 由于碘 1 2 5半 衰期 比较短 ,试 剂 稳 定 性 略差 ,有 效期 短 。化 学 发光 法 是具 有 高度 敏 感性 和高 度 特 异性 的先进 技 术 ,同 时具 有光 学 检测 的敏感 性 及 免疫 分析 法 的特 异性 ,原理 在 于 以发 光剂 直 接标 记 抗体 ,利用

美艾利尔五联板产品介绍

美艾利尔五联板产品介绍
中的分析物的浓度
The body talks. We translate.
Triage® 系统
Triage Meter平台
• Triage® Meter – 由 Biosite® LRE 公司生产 – 运行个体检测装置 – 15分钟内得到定性结果 – 内置 QC, QA 功能 – 便携式系统 – 可存储, 打印和显示结果 – HIS接口 – LIS接口
化学反应
分析物+ 试剂
产物
(抗原)
(抗体) 温度、时间 (抗原抗体复合物)
均相免疫测定 异相免疫测定
The body talks. We translate.
免疫自动分析系统的原理
•均相免疫测定(B,F不需分离)
பைடு நூலகம்Ag + Ab
AgAb
+ Ab
直接在自动分析仪中 测定浓度
(B) (F)
•异相免疫测定(B,F需分离)
The body talks. We translate.
床旁检测(POCT)心脏标志物的市场概况
• 小型低速仪器(POCT) 心脏标志物的检测约占总市场份额的36%, 2010年总的销售超过10.4亿人民币。
• 二级医院拥有POCT心脏标志物检测的不超过25%。所以该市场的需 求巨大,增长速度快。
Cardiac Reader / h 232
Stratus CS
iSTAT
E170,Elesys2010
Centaur,ACS 180, Immulite ,Dimension
I 2000,AxSym
Pathfast
Triage Meter Pro
The body talks. We translate.

poct法与化学发光法检测肌钙蛋白i的比较研究

poct法与化学发光法检测肌钙蛋白i的比较研究
学术论著
中国医学装备2020年2月第17卷第2期 China Medical Equipment 2020 February Vol.17 No.2
POCT法与化学发光法检测肌钙蛋白I的比较研究*
范雪松① 贺建勋① 宋 扬① 桂 媛① 赵 松① 崔 颖② 袁 慧①*
[文章编号] 1672-8270(2020)02-0092-04 [中图分类号] R446.1 [文献标识码] A
Comparative study of POCT method and chemiluminescence method in detection of cTnI/FAN Xue-song, HE Jian-xun, SONG Yang, et al//China Medical Equipment,2020,17(2):92-95.
疫分析仪检测cTnI的相关性和一致性。结果:POCT检测系统在阴性组和低浓度组与参比检测系统相关性较差(P>0.05),
在中浓度组和高浓度组与参比检测系统相关性较好(r=0.753,r=0.861;P<0.05)。POCT检测系统与参比检测系统的cTnI
结果相关性较好(r=0.862,P<0.05)。Beckman DXI800和CL-2000i型化学发光免疫分析仪与参比检测系统具有很强的相
关性(r=0.985,r=0.977;P<0.05)。结论:POCT法检测中浓度和高浓度cTnI时与化学发光免疫分析仪法有良好的相关
性,但检测阴性和低浓度cTnI时与化学发光免疫分析仪法相关性较差。
[关键词] 心肌标志物;即时检验(POCT);电化学发光法;化学发光法;肌钙蛋白I
DOI: 10.3969/J.ISSN.1672-8270.2020.02.025

雅培i2000SR和安图A2000 Plus检测游离三碘甲状腺原氨酸结果的对比分析

雅培i2000SR和安图A2000 Plus检测游离三碘甲状腺原氨酸结果的对比分析

・118・Proceeding of Clinical Medicine,Feb.2021,Vol30No.2文章编号:1671—8631(2021)02—0118—04雅培I2000SR和安图A2000Plus检测游离三碘甲状腺原氨酸结果的对比分析梁卡",蓝吉慧2,张红雨】,柯柳华】,黄卫信1(1.广西壮族自治区柳州市中医医院,广西柳州545001;.广西壮族自治区龙潭医院,广西柳州545005)摘要目的:探讨不同化学发光检测系统检测血清游离三碘甲状腺原氨酸(FT3)结果的可比性。

方法:选取2019年11月5日-2019年11月7日75例门诊患者的血清样本,在相同的工作环境下使用雅培I2000SR和安图A2000 Plus两台仪器平行测定血清FT3的浓度,并对两组测定结果进行比较和相关性分析。

结果:安图A2000Plus对不同浓度FT3的检测结果高于雅培I2000SR,差异具有统计学意义(P V0.05),同时这两台仪器检测FT3的结果具有良好的相关性(=0.9817>0.975)。

Bland—Altman分析结果显示安图A2000Plus检测FT3的结果约为雅培I2000SR 的1.34倍。

结论:当同一实验室存在不同的检测系统检测相同的项目时,都应对不同检测系统的检测结果进行比对分析,保证检验结果的可比性,判断临床可接受性,以更好地指导临床诊疗。

关键词雅培I2000SR;安图A2000Plus;游离三碘甲状腺原氨酸;检测系统;相关性中图分类号:R581文献标识码:BComparison and analysis of free triiodothyronine detected by Abbott i2000SR and Antu A2000Plus LIANG Ka1,LAN Jihui2,ZHANG Hongyu1,KE Liuhua1,HUANG Weixin1(1.Liuzhou Traditional Chinese Medical Hospital,Liuzhou545001,China;2.Longtan Hospital of Guangxi Zhuang Au­tonomous Region,Liuzhou545005,China)Abstract Objective:To discuss the comparability of serum free triiodothyronine(FT3)detected by different chemiluminescence detection systems.Methods:Serum samples of75out—patients in hospital from November5,2019 to November7,2019were selected.Under the same working conditions,the FT3concentration of these serum samples were measured by the above two instruments,and the results of the two groups were compared and made a correlation analysis.Results:The results of FT3in different concentrations detected by antu A2000Plus were higher than those de­tected by abbott i2000SR,and the difference was statistically significant(P<0.05).At the same time,the results of FT3detected by these two instruments had a good correlation,the correlation coefficient(r=0.9817>0.975).The re­sults of bland一altman analysis showed that the FT3detected by Antu A2000Plus was about1.34times as high as Abbott i2000SR.Conclusion:When a laboratory has different detection systems to test the same items,relevant measures should be established and the results of different detection systems should be compared and analyzed,t o ensure the com­parability of test results and to judge the clinical acceptability for better guidance of clinical diagnosis and treatment.Key words Abbott i2000SR;Antu A2000Plus;free triiodothyronine;test system;comparison;relevance游离三碘甲状腺原氨酸(FT3)是人体循环血中甲状腺激素的生物活性部分,不受甲状腺结合球蛋白含量的影响,与机体代谢状态一致,可直接反映甲状腺功能状态[1\FT3不仅在甲状腺功能亢进(以下简称甲亢)、甲状腺功能减退(以下简称甲减)、亚急性甲状腺炎等多种甲状腺疾病的诊断上有重要的价值[2—3],在甲状腺疾病的病情评估、疗效监测等方面也有重要的临床指导意义4。

固相免疫层析定性法和化学发光定量法检测心肌肌钙蛋白Ⅰ比较

固相免疫层析定性法和化学发光定量法检测心肌肌钙蛋白Ⅰ比较

固相免疫层析定性法和化学发光定量法检测心肌肌钙蛋白Ⅰ比较张静瑜;张伟;夏昌宇;徐国宾【摘要】目的观察固相免疫层析快速定性检测方法在心肌肌钙蛋白Ⅰ (cTnI)不同浓度范围内与定量方法结果比较的符合率,评价cTnI定性方法的应用价值.方法用美国普林斯顿医学生物技术(PBM)公司固相免疫层析快速测试板定性检测399份患者血浆样本cTnI浓度,同时与Beckman Coulter免疫化学发光定量法的结果进行比较.以cTnI>0.04 ng/L为阳性诊断切点,将样本按cTnI浓度由低至高分为6组,第1组为cTnI定量阴性组,其他5组均为定量阳性组.结果第1组阴性符合率及第2~6组阳性符合率分别为98.0%、3.4%、17.3%、46.2%、94.4%和100.0%.定量法阴性组有3份样本定性法阳性,分别是黄疸、乳糜和高类风湿因子(RF)水平样本.结论 cTnI定性法检测特异性高,但应注意干扰因素影响;由于定性法敏感性低,阴性时仍应进行定量检测.【期刊名称】《临床检验杂志》【年(卷),期】2013(031)008【总页数】2页(P571-572)【关键词】心肌肌钙蛋白Ⅰ;急性心肌梗死;化学发光法;床旁即时检测【作者】张静瑜;张伟;夏昌宇;徐国宾【作者单位】北京大学第一医院检验科,北京100034;北京大学第一医院检验科,北京100034;北京大学第一医院检验科,北京100034;北京大学肿瘤医院检验科,北京100142【正文语种】中文【中图分类】R446.1心肌肌钙蛋白I(cardiac troponin I,cTnI)是重要的心肌损伤标志物。

根据欧洲心脏病学会(ESC)、美国心脏病学学会(ACC)以及美国心脏学会(AHA)发表的指南文件,cTnI已成为急性心肌梗死(AMI)诊断的首选心脏标志物[1-2]。

心肌坏死标志物检验回报时间(TAT)应小于1 h,最好小于30 min[3]。

但只有极少数医院能满足这样的标准。

即时检测仪器与电化学发光仪检测心脏标志物的对比研究

即时检测仪器与电化学发光仪检测心脏标志物的对比研究

即时检测仪器与电化学发光仪检测心脏标志物的对比研究刘文娟;郭盼;杜娟;张何锐;王雅平;王海龙;徐佳;李琦【期刊名称】《中国医学装备》【年(卷),期】2024(21)5【摘要】目的:对比分析两种即时检测(POCT)仪器与Roche电化学发光仪检测心脏标志物的相关关系,为临床检验选择POCT仪器提供参考。

方法:选取2020年11月在中国中医科学院西苑医院就诊的20例患者血液样本,其浓度范围覆盖检测结果可报告范围,使用两种POCT仪器(分别命名为仪器A和仪器B)检测血浆肌红蛋白(Myo)、肌酸激酶同工酶质量(CKMB mass)、心肌钙蛋白I(cTnI)、氨基末端脑钠肽前体(NT-proBNP)/B型钠尿肽(BNP)的浓度水平,以电化学分析仪检测结果为参考,分别采用pearson相关分析和Kappa检验评价两种POCT仪器与Roche电化学发光仪检测结果的相关性和一致性。

结果:仪器A和仪器B检测结果与Roche电化学发光仪检测Myo、CK-MB mass、cTnI、NT-proBNP/BNP结果均有较好的相关性(r_(仪器A)=O.994、0.989、0.917、0.996,r_(仪器B)=0.928、0.934、0.883、0.977,P<0.05)。

在一致性比较中,仪器A检测Myo、CK-MB mass、cTnI、NT-proBNP与电化学分析仪的符合率分别为90%、100%、70%和100%;仪器B 检测结果的符合率分别为90%、95%、70%和100%,两种POCT仪器与Roche电化学发光仪均具有较好的一致性(Kappa_(仪器A)=0.798、1.00、0.429、1.00,Kappa_(仪器B)=0.794、0.886、0.429、1.00)。

两种仪器的精密度均<10%。

结论:两种POCT仪器均能满足临床检测要求,在检测心脏标志物时与电化学发光仪有较好的相关性。

【总页数】5页(P16-19)【作者】刘文娟;郭盼;杜娟;张何锐;王雅平;王海龙;徐佳;李琦【作者单位】中国中医科学院西苑医院检验科【正文语种】中文【中图分类】R197.39【相关文献】1.ELISA法与电化学发光法在检测乙肝病毒血清标志物结果中的对比应用研究2.标本类型对电化学发光法检测心脏标志物结果影响初探3.电化学发光免疫法和酶联免疫法检测乙肝病毒标志物的临床对比研究4.溶血对电化学发光法检测心脏标志物的影响5.电化学发光免疫法与ELISA法检测乙型肝炎病毒标志物对比研究因版权原因,仅展示原文概要,查看原文内容请购买。

化学发光免疫法检测GADA、ICA、ZnT-8A在T1DM诊断中的应用研究

化学发光免疫法检测GADA、ICA、ZnT-8A在T1DM诊断中的应用研究

化学发光免疫法检测GADA、ICA、ZnT-8A在T1DM诊断中的应用研究李彦青;赵鸿斌;孙晓慧【摘要】目的对比分析免疫印迹法(IB法)及化学发光免疫法(CLISA法)检测谷氨酸脱羧酶抗体(GADA)、胰岛细胞抗体(ICA)、锌转运蛋白8抗体(ZnT-8A)结果 ,探讨这三种抗体联合检测对T1DM的临床意义.方法选取2015年1月至2016年10月内分泌科收治的100例糖尿病患者的临床资料,其中T1DM 32例, T2DM 68例及100例健康人群(健康对照组),分别采用IB法及化学发光酶免疫法进行GADA、ICA、ZnT-8A检测.结果 T1DM组CLISA法检测 GADA、ICA及ZnT-8A,阳性率明显高于T2DM组和健康对照组,差异有统计学意义(P<0.05);CLISA法检测GADA、ICA及ZnT-8A,敏感性均高于IB法,差异有统计学意义(P<0.05);CLISA法检测 ICA及ZnT-8A,特异性均高于IB法,差异有统计学意义(P<0.05).结论化学发光酶免疫法检测GADA、ICA、ZnT-8A对诊断T1DM有更高的临床价值.【期刊名称】《河北医药》【年(卷),期】2017(039)019【总页数】3页(P2940-2942)【关键词】T1DM;GADA;ICA;ZnT-8A;免疫印迹法;化学发光免疫法【作者】李彦青;赵鸿斌;孙晓慧【作者单位】050011 河北省石家庄市第一医院检验科;050011 河北省石家庄市第一医院检验科;050011 河北省石家庄市第一医院检验科【正文语种】中文【中图分类】R587.1糖尿病(DM)是一组以高血糖为典型特征伴有多种并发症的慢性代谢紊乱综合征,多由胰岛素分泌缺陷或生理活性受损所致,已成为当前临床上的主要内分泌代谢疾病,根据发病机制不同,临床上主要分成1型糖尿病(type 1 diabetes mellitus,T1DM)和2型糖尿病(type 2 diabetes mellitus,T2DM)。

POCT 法与 ACCESS化学发光法检测心肌标志物的比对

POCT 法与 ACCESS化学发光法检测心肌标志物的比对

POCT 法与 ACCESS化学发光法检测心肌标志物的比对何啸;管华玲【期刊名称】《国际检验医学杂志》【年(卷),期】2015(000)021【摘要】目的:评价床旁检测(POCT)在急性心肌梗死(AMI)患者中的应用价值。

方法收集140例疑似AMI患者血清标本,以电化学发光法作为参考方法,以POCT法作为实验方法,比较两种方法检测心肌肌钙蛋白I(cTnI)、肌红蛋白(Myo)、肌酸激酶同工酶MB质量(CK‐MBmass)的相关性,评价POCT检测系统的批内精密度。

结果 POCT法检测低浓度cTnI时,与电化学发光法相关性较差(P>0.05),检测中浓度与高浓度cTnI时,相关性良好(P<0.05)。

POCT法与电化学发光法Myo、CK‐MB‐mass检测结果相关性良好(P<0.05)。

POCT法检测结果对AMI的诊断特异度高于电化学发光法,但灵敏度低于电化学发光法(P<0.05)。

结论 POCT 法检测中、高浓度cTnI时,与电化学发光法有良好的相关性,但检测低浓度 cTnI时相关性较差。

POCT法与电化学发光法Myo、CK‐MBmass检测结果具有良好相关性。

POCT法对AMI的诊断特异度高,但灵敏度较低。

【总页数】3页(P3171-3173)【作者】何啸;管华玲【作者单位】盐城市第一人民医院输血科,江苏盐城224001;盐城市第一人民医院输血科,江苏盐城224001【正文语种】中文【相关文献】1.POCT法与Roche电化学发光法检测心肌标志物的比较 [J], 黄静沁;左玫;李智;于慧;孙仲华;穆福华2.快速检测法与化学发光法检测心肌标志物的比较 [J], 陆群;殷继华;赵延荣3.5种床旁检测法与Abbott化学发光法检测心肌标志物的对比研究 [J], 胥国强;康清秀;李文楷;罗映杰4.POCT与电化学发光法检测急性胸痛患者心肌损伤标志物的对比分析 [J], 曾金石5.电化学发光免疫法检测血清心肌损伤标志物及心肌酶学在心肌梗死中的应用 [J], 户雪冬;户秋冬;刘阳贵因版权原因,仅展示原文概要,查看原文内容请购买。

不同化学发光仪器方法比对-路其凤

不同化学发光仪器方法比对-路其凤

质量控制


试剂 试剂均与仪器配套 质控物 质控物有两种:一种为自制质控,来源于实验室分装 的正常人混合血清,用于日常监测;另一种为原厂提 供的对应仪器的三值质控,用于定期监测 实验中 遵循实验室和或制造商的常规质量控制程序,保留质 控图,任一方法出现失控时应重新测定,直至达到要 求的样本数为止
பைடு நூலகம்
比对前的基本要求

待评方法和参比方法的操作者必须熟悉以下工 作: ①操作 ②保养程序 ③样本准备方法 ④校准和监控功能
参比方法的选择

实验室当前使用的方法,生产厂家声明的方法和公认 的参考方法都可作为参考方法 参比方法应该做到如下几点 具有比待评方法更好的精密度; ⑴可能的情况下,不受已知干扰物的干扰; ⑵使用与待评方法相同的单位 ⑶可能的情况下,与标准品或参考方法有已知的可溯 源 ⑷参比方法的分析范围应至少与待评方法的范围相同, 以便在分析测定范围内可以比较。
删除数据的文件化

原则 任何需要删除的数据均应仔细形成文件保留, 记录所发现的原因和问题
样本


检测样本 ⒈按照实验室操作规范和制造商的推荐收集和 处理患者标本 ⒉ 在医学决定水平范围内评价待评方法,分 析浓度通常应从低值参考范围到高值参考范围; 尽可能在测定范围内均匀分布。 样本数量
测定

每天8份 第一次正序,第二次反向测定,eg:第一次: 12345678,第二次:87654321 同时测定自制质控和三值质控 注意:2小时内完成
数据收集过程中的检查



分析系统误差 仪器显示存在误差时收集的数据需成文,但在最后的 数据分析中不要包括在内 人为误差 记录任何操作者造成的有文件的误差,但在最后的数 据分析中不要包括在内 其它不一致数据的处理 没有查出错误的不一致双份数 据时,也应记录而不是剪辑。不能确定不一致的原因 时,则应在数据表上保留原始数据,必须进行离群值 的检验
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

死 (AMI)患者 生命 的关 键 。AMI患 者 临 床症 状 有 时并 考值 的上 限判 断 为 阳 性 ,小 于 参 考 值 的 上 限 判 断 为
不典 型 ,心 电 图也有 可 能呈 非 特异 性 改 变 ,因此心 肌 标 阴性 。
志物 检 测成 为早 期 诊 断 AMI的重 要 依 据 _3 J。因 常 规 1.4 批 内精 密度 测 定 :采 用 POCT检 测 系 统 ,在 2h内
在 各 医 院使 用 的心 肌 标 志 物 POCT试 剂 有 多 种 ,并 且 员 会 推 荐 的 标 准 ,当 CV c T『lI<10% 、CVMB<5.6% 、
· 158 ·
四川医学 2018年 2月第 39卷 (第 2期 ) SichuanMedical Journal2018,Vo1.39,No.2 ,
the sensitivity of the method and try to choose POCT detection system which test results are consistent tolarge laborator y analyzer SO as to reduce unnecessary m isdiagnosis or missed diagnosis.
84.6% ,92.3% and 61.5% respectively.Th e Kappa values were 0.58,0.84 and 0.27 respectively.The coincidence rates of Mb, CK—MB and CTn1 were 87.5% ,95.0% ,80.0% and Kappa values were 0.75,0.89 and 0.58respectivelyin Tr iage detection sys—
四川医学 2018年 2月第 39卷(第 2期 ) SichuanMedical Journal,2018,Vo1.39,No.2 doi:10.16252/j.cnki.issn1004-0501-2018.02.013
·157 ·
论 著
5种床 旁检 测 法与 Abbott化 学发 光 法检 测 心 肌标 志 物 的对 比研 究
Abbott chemiluminescence method,the coincidence rates of Mb,CK—MB a nd CTnI in Getein 1 100 detection system(f luorescence immunoassay method)were 84.6% ,76.9% and 53.8% respectively.The Kappa values were 0.58,0.52 and 0.13 respectively. The coincidence rates of Mb,CK—MB and CTnI measured by ZYbio—Q7 detection system(immunochromatography method)were
一 , 其 中又 以心 肌 梗 死 的 死 亡 率 最 高 。据 世 界 心 脏 联 京诺 尔 曼 NRM—cl一200化 学 发 光 定 量 分 析 仪 及 检 测
盟 预计 ,到 2020年心 肌 梗 死 从 目前 死 因排 行 榜 的 第 5 Mb、CK—MB、CTnI配套 试 剂 ;丹 麦 雷 度 AQT90快 速 免
位升 至 第 1位 … 。心肌 损伤 标 志物 的检 测对 急性 冠脉 疫分析仪及检测 Mb、CK.MB、CTnI配套试剂 。严格按
综合 征 患者 的危 险 分 层 、急 性 心 肌 梗 死 的诊 断 和 预 后 照 说 明书操 作 ,所有 试剂 均在 有效 期 内 。
具有 重 要 意义 l2 J。早 诊 断 、早 治 疗 是 挽 救 急 性 心 肌 梗 1.3 结果 判 定 :根 据 试 剂 说 明 书 ,所 测 定 的值 大 于参
【Key words】 bedside detection;cardiac markers;chemiluminescence;evaluation studies
心 血管 系统 疾 病是 影 响人 类 健康 最 严 重 的疾 病 之 荧 光免疫 分 析仪 及检 测 Mb、CK.MB、CTnI配套 试 剂 ;南
方法检测时间长 ,不利 于患者的及时诊检测 10次 ,计算检
(POCT)因不 受 时 间 、地 点 限 制 ,检 测 速 度 快 、操 作 简 测 结果 均值 ( )、标 准 差 (S)和 变 异 系 数 (CV)。根 据
便 、仪 器 小 型化 等 特 点 ,迅 速 在 各 医 院开 展 J。 目前 国际 临床化 学 与检验 医学联 合 会 心肌 标 志 物标 准 化 委
【关键词】 床旁检测;心肌标志物;45学发光;评价研究 【中图分类号 】 R 542.22 【文献标志码】 A 【文章编 号】 1004-0501(2018)02-0157-04
Com parison of Five PO CT M ethods and A bbott Chem ilum inescence in Detecting M yocardial M arkers.Xu Guoqiang,
tem(f luorescence immunoassay method).The coincidence rates of Mb,CK—MB and CTn1 were 92.5% ,75.O% and 92.5% re— spectivetyand the Kappa valueswere 0.85,0.53 and 0.85respectively in the NRM—el-200 detection system(chemil method).The coincidence rates of Mb,CK—MB an d CTn1 were 92.5% ,92.5% ,90.O% respectively and the Kappa valueswere 0.85,0.84 and 0.80 respectively in the AQT90 detection system(time-resolved immunof luorescence method).The in—batch preci— sion of Mb measured by Getein 1100,ZYbio—Q7,Triage,NRM—cl一200 and AQT90 was 0.51% ,1.38% ,1.31% ,1.87% and
0.96% respectively.The in—batch precision of CK·MB was 3.23% ,9.5 1% ,3.54% ,4.42% and 2.12% respectively.The in—batch precision of CTn1 was 4.56% ,5.78% ,6.47% ,14.29% and 2.29% ,respectively.Conclusion The detection results of the f ive POCT methods a r e different.As the POCT detection method of m yocardial markers,it is necessary for dom estic reagents to im prove
ence for the selection of bedside detection.M ethods The plasma samples from 40 inpatients were collected and the plasma con- centrations of M b,CK—M B and CTn1 were measured by six methods.Chem iluminescence was used as a standard to compare the all— alytical perform ance of five POCT methods and to evaluate the in—batch precision of the detection system.Results Compared with
胥 国强 ,康 清 秀 ,李 文楷 ,罗映杰
(遂 宁市 中心 医 院 ,四川 遂 宁 629000)
【摘 要】 目的 评价床 旁检 测(POCT)法检测心肌标 志物 的分析性 能 ,为床 旁检测选择 方法提供 参考。方法 收 集 40例 住 院 患者 的血 浆样 本 ,用 6种 方 法 检 测 血 浆 肌 红 蛋 白 (Mb)、肌 酸 激 酶 同工 酶 (CK—MB)、肌 钙 蛋 白 I(CTnI)的 浓 度 ,并 以实验 室 Abbott化 学发 光法为标 准 ,比较 5种 POCT法 的分析性 能 ,并评价其检 测 系统的批 内精密度 。结果 与 Abbott 化学发光法 比较 ,Getein 1100检 测 系统(荧光免 疫定量 )所测 Mb、CK—MB、CTnI的符合 率分别 为 84.6% 、76.9%、53.8% , Kappa值 分 别 为 0.58、0.52、0.13;ZYbio—Q7检 测 系 统 (免 疫 层 析 法 )所 测 Mb、CK—MB、CTnI的 符 合 率 分 别 为 84.6% 、 92.3% 、61.5% ,Kappa值 分 别 为 O.58、0.84、0.27;Triage检 测 系统 (荧光 免 疫 定 量 )所 测 Mb、CK—MB、CTnI的符 合 率 分别 为 87.5% 、95.O% 、80.0% ,Kappa值 分别为 0.75、0.89、0.58;NRM—cl一200检 测 系统(化 学发 光法)所测 Mb、CK—MB、CTnI的符 合率分别为 92.5% 、75.0%、92.5% ,Kappa值分别为 0.85、0.53、0.85;AQT90检测 系统(时间分辨免 疫 荧光法)所测 Mb、 CK-MB、CTnI的 符 合 率 分 别 为 92.5% 、92.5% 、90.0% ,Kappa值 分 别 为 O.85、0.84、0.8O。 Getein 1100、ZYbio—Q7、Tr iage、 NRM-el-200、AQT90各 检 测 系统 所测 Mb的批 内精 密 度 分 别 为 0.51% 、1.38% 、1.31% 、1.87% 、0.96% ,所 测 CK—MB的 批 内精 密 度 分 剐 为 3.23% 、9.51% 、3.54% 、4.42% 、2.12% ,所 ;I!Il CTnI的 批 内 精 密 度 分 别 为 4.56% 、5.78% 、6.47% 、 14.29% 、2.29%。结论 5种 POCT法之 间检测结果存在差异 ,作为心肌标志物 的 POCT检 测方法 ,国产试 剂有 必要进一 步改进 方法提 高其敏 感性。应尽量选择与 实验 室 内大型 分析仪检 测 结果保 持一 致的 POCT检 测 系统 ,减 少不必要 的误 诊 、漏诊 。
相关文档