产品规格书(SPEC.)产品名称重量模块产品说明重量模块目录1.0Revision History (3)2.0General Description (4)3.0Selection Table (5)4.0Application Circuit and Description (5)5.0Pin Assignment (6)6.0Pin Description (8)7.0Electrical Characteristics (8)8.0Function Description (10)8.1IIC interface: (10)读取重量 (10)去皮&标定 (11)休眠118.2UART interface: (12)9.0Tool Information (14)1.0 Revision History2.0 General DescriptionBMH01xxx是Holtek推出的高精度称重模块。

BMH011xx为全桥双孔悬臂平行梁应变片传感器搭配Holtek专为高精度称重传感器而设计的24位A/D转换芯片,可做到1g或者更低的称重精度。

称重范围为1.5kg、5kg。

常应用于智能水杯,咖啡机等产品。

BMH012xx为半桥山型应变片传感器搭配Holtek专为高精度称重传感器而设计的24位A/D转换芯片,可做到5g或者更低的称重精度。

称重范围为20kg。

常应用于榨汁机、咖啡机等智能产品。

与同类型模块相比其主要优势是:1.内部集成稳压电源,宽电源输入范围2.待机功耗低:<1uA3.PCBA Size:12mm*13mm(BMH011XX);16mm*16mm(BMH012XX)4.直接输出重量值,不需要用户在做AD转换,降低开发成本5.标准IIC/UART接口6.针对不同量测范围,提供不同模块选型7.IIC/UART命令动态去皮功能BMH011xx BMH012xx Application:3.0 Selection Table4.0 Application Circuit and DescriptionIIC接口UART接口注:1.若对精度及抗干扰效果有要求建议保留0.1uF及47uF电容。

Vortex Mixer F202A0173 产品说明书

Vortex Mixer F202A0173 产品说明书

Instruction ManualManuale di istruzioniManu el d’instructionsManual de instruccionesBedienungsanleitung指导手册CLASSIC Vortex MixerF202A0173General Information / Informazioni Generali / Informations Générales / Información General / Allgemeine Hinweise / 一般信息Before using the unit, please read the following instruction manual carefully.Prima dell’utilizzo dello strumento si raccomanda di leggere attentamente il seguente manuale operativo.Avant d’utiliser l’instrument, il est recommandé de lire a ttentivement le présent manuel d’instructions.Antes de utilizar el instrumento, le recomendamos que lea con atención el siguiente manual de funcionamiento.Bitte lesen Sie vor Inbetriebnahme des Geräts diese Bedienungsanleitung sorgfältig durch在使用本装置之前,请仔细阅读以下使用说明书。

Do not dispose of this equipment as urban waste, in accordance with EEC directive 2002/96/CE.Non smaltire l’apparecchiatura come rifiuto urbano, secondo quanto previsto dalla Direttiva 2002/96/CE.Ne pas recycler l’appareil comme déchet solide urbain, conformément à la Directive 2002/96/CE.No tirar el aparato en los desechos urbanos, como exige la Directiva 2002/96/CE.Dieses Gerät unterliegt der Richtlinie 2002/96/EG und darf nicht mit dem normalen Hausmüll entsorgt werden.根据EEC指令2002/96/CE,请不要将本设备作为城市垃圾处理。

C2000-D2-TATS01 使用说明书

C2000-D2-TATS01 使用说明书

2020年5月9日 更新C2000-D2-TATS01 使用说明书6 * RS485 + 4 * DI + 4 * DO边缘计算 — 边缘计算网关深圳市中联创新自控系统有限公司Shenzhen United Innovation Automatic Control System Co., Ltd.2666991013131617192121232323242525262829303030303132323233343436363636373838404141424243444747484951525354555959目录目录1. 快速使用1.1. 使用前准备1.2. 设备接线1.3. 设备搜索及调试1.3.1. 设备搜索及参数设置1.3.2. 设备调测2. 硬件说明2.1. 技术参数2.2. 产品外观2.3. 指示灯2.4. 端口说明2.5. 尺寸2.6. 安装方式3. Web 功能介绍3.1. 触摸屏登录3.2. WEB 浏览器登录3.3. 首页内容3.4. 配电图3.5. UPS 3.6. 空调3.7. 环境3.8. 告警3.9. 历史3.9.1. 历史告警3.9.2.3.9.3. 历史数据3.10. 抓拍记录3.11. 设备配置信息3.11.1. 查询设备配置信息3.11.2. 设备点值3.11.3. 设备状态3.11.4. 告警通知3.11.5. 门禁设置4. 设备配置说明4.1. MC Monitor system 配置工具简介4.1.1. “系统”页签--基础服务相关4.1.2. “后台”页签--告警及北向后台管理相关4.1.3. “前端”页签--页面显示内容配置相关4.2. 登录MC Monitor system 4.2.1. 用配置工具搜索设置IP 4.2.2. 登录4.3. 6.3 基础操作4.3.1. 从服务器加载配置4.3.2. 当前配置上传至服务器4.3.3. 数据备份4.3.4. 数据还原4.3.5. 授权下载及上传4.4. 监控显示相关的配置4.4.1. 首页4.4.2. 市电参数4.4.3. UPS 参数4.4.4. IT 用电参数4.4.5. 空调参数4.4.6. 环境参数4.5. 配电图4.5.1. 组态修改4.6. 采集相关配置4.6.1. 设备模板管理60616264646667686869707070717273744.6.2. 创建采集设备4.6.3. 修改采集设备4.6.4. 表达式4.7. 告警/联动相关配置4.7.1. 告警配置4.7.2. 告警联动4.7.3. 告警收敛4.8. SNMP 北向接口相关配置4.8.1. 配置SNMP 转发内容4.8.2. 导出MIB 库4.9. 其它功能配置4.9.1. 屏保、抓拍间隔配置4.9.2. NTP 校时4.9.3. 短信告警通知4.9.4. TF 卡检测5. 装箱清单6. 产品服务【版权声明】©2000 - 2020 中联创新版权所有【商标声明】及其它中联创新服务相关的商标均为深圳市中联创新自控系统有限公司及其关联公司所有。

毯浩伊龙系统自动化控制有限公司商品说明书

毯浩伊龙系统自动化控制有限公司商品说明书
ECODRIVE DKC03.1 Drive Controller
ECODRIVE DKC03.1 Drive Controller
ECODRIVE DKC03.1 Drive Controller
ECODRIVE DKC03.1 Drive Controller
ECODRIVE DKC03.1 Drive Controller
ECODRIVE DKC03.1 Drive Controller
ECODRIVE DKC03.1 Drive Controller
ECODRIVE DKC03.1 Drive Controller
ECODRIVE DKC03.1 Drive Controller
ECODRIVE DKC03.1 Drive Controller
ECODRIVE DKC03.1 Drive Controller
ECODRIVE DKC03.1 Drive Controller
ECODRIVE DKC03.1 Drive Controller
ECODRIVE DKC03.1 Drive Controller
ECODRIVE DKC03.1 Drive Controller
PDP 03VRS
DOK-ECODRV-PDP-03VRS**-FKB1-EN-P • 11.96 **********************************************************(+34)960624301
ECODRIVE DKC03.1 Drive Controller
ECODRIVE DKC03.1 Drive Controller
ECODRIVE DKC03.1 Drive Controller

mc2中文说明书

mc2中文说明书

安全性
MC2 可以经受工业环境的考验,具有很好的防震功能。它十分精密灵
武汉联合约克仪器有限公司 编译
7
York instrument LTD
巧,对使用者的技术要求比较高。而且必须对操作手册有个好的理解。 尽量避开电磁信号源,以免影响到测量精度。 可充电电池在充电的过程中会发出少许气体,这种气体是易爆的,虽
要有超过 60V 直流、30V 交流和 100mA 的电信号。 MC2 最大输出电压低于 30V,所以输入、输出的时候千万小心。
废弃电池与材料的处理 贝美克斯很注重对环境的保护,他设计的产品很容易回收利用而不污
染环境。 欧盟和其他国家联合建立了一个体系——WEEE。WEEE/EC 要 求所有生产电器电表的厂家对产品的回收和循环利用负责。这一政策在 2005 年 8 月在欧洲市场实施。旨在保护环境、保护人类身体和维持自然资
源。标签上引有
符号的,表示可再回收利用。
建议 不要随便打开 MC2 外壳。只有具备资格的专业技术人员才能维修。 充电器不能维修,请依据环保法规妥善处理废弃的充电器。 若重新设置 MC2,同时按下回车键和开关键 5 秒钟。然后再次按下开
关键即可。重设后 MC2 的时钟回到 1970 年 1 月 1 日 0 点。记得输入正确 的时间。不建议重设。详细可咨询武汉约克仪器公司。 若清洁 MC2,用软布沾些清洁油擦拭。过几分钟,再用湿布擦干。
武汉联合约克仪器有限公司 编译
10
内部压力模块(IPM)
York instrument LTD
压力模块类型:
·IPM200mC 量程:±200mbar(±20 kPa)
·IPM2C 量程:-1 ̄+2bar(-100 ̄+200 kPa)

科达产品手册

科达产品手册
客户咨询热线:800-828-2866 400-828-2866
CN-007011R-20110930-009
科达 201 1 监控产品手册
科达监控产品手册 2011
管理平台
12 KDM2801中心管理平台 13 KDM2801E中心管理平台 14 KDM2802中心管理平台 15 KDM2901专网软件平台
1×RCA, Line In 1×RCA,Line Out
2×eSATA 8×SATA
2×eSATA 8×SATA
2×eSATA 8×SATA
2×eSATA 8×SATA
4×USB 2.0 4×USB 2.0 4×USB 2.0 4×USB 2.0
1×RCA, Line In 1×RCA,Line Out
F2.0
0Lux(红外灯开启时)
1/3英寸高性能
传感器
420TVL 3.6mm
F2.0
0Lux(红外灯开启时)
可配各类标准摄像机芯
红外 视频分辩率 音频接口
D1、CIF、
1×Line In,
-
QCIF,双码流 1×Line Out
D1、CIF、
1×Line In,
-
QCIF,双码流 1×Line Out
1080P、720P、 D1、CIF、QCIF -
720P、D1、 CIF、QCIF
1×VGA Out 1×HDMI Out
720P、D1、 CIF、QCIF
720P、D1、 CIF、QCIF
1×VGA Out 1×HDMI Out
1×VGA Out 1×HDMI Out
1080P、720P、 D1、CIF、QCIF
标清网络摄像机
42 IPC100P枪型网络摄像机 43 IPC200P红外防水网络摄像机 44 IPC201P固定半球红外网络摄像机 45 IPC202P固定半球防暴网络摄像机 46 IPC300P室内型PTZ网络摄像机 47 IPC301P室内型PT网络摄像机 48 IPC302P室内型PT网络摄像机 49 IPC400P室外高速球型网络摄像机

D2MC-5H中文资料

D2MC-5H中文资料

138Low-torque Basic SwitchD2MCHighly Reliable Rotary-action Switch for Low Torque Operation0.5 A rated model (D2MC-01j ) employs crossbar alloy #1 contacts which exhibit unsurpassed contact reliability in very small load ranges.High-capacity 5 A Model (D2MC-5j ) employs silver contacts.Long life (10,000,000 mechanical operations min.)through use of a movable coil spring.Note:All the models listed here are supplied without actuator lever . If an actuator lever is required, please order separately by indicating the model name of the actuator lever .See Accessories.RatingsContact FormCharacteristicsNote:All the models listed here are supplied without actuator lever. If an actuator lever is required, please order separately by indicating the model name of the actuator lever.See“Accessories”.Approved StandardsUL (File No. E41515)CSA (File No. LR21642)D2MC-5j series:5 A, 125 V AC5 A, 250 V ACD2MC-01j series:0.5 A, 125 V AC0.5 A, 30 VDC139140Mechanical Life ExpectancyElectrical Life ExpectancyOvertravel (mm)Switching current (A)N u m b e r o f o p e r a t i o n s (x 10 )3N u m b e r o f o p e r a t i o n s (x 10 )3Without loadOperating frequency: 240 operations/minuteOvertravel (deg)Operating frequency: 20 operations/minute0.1 A 125 VAC0.5 A 125 VAC5 A 250 VAC2.Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.Snap-on MountingCounterclockwiseMounting HolesTwo 3.1 dia. mounting holes or M3 screw holes31#205 series quick connect terminals (0.8 t)18.21714.11027.817.5FPPT OT 9950.823.68.7±0.13.1±0.054±0.1 dia.0.8Operating direction3.1±0.05 dia.3.623.8±0.118±0.1PT FPOT Clockwise141CAA1M for Snap-on Mounting0.6 dia. stainless steel wire50±1In addition to the standard wire lever model shown here, various other levers are available upon request.Mounting Actuator Lever1.Insert the end ofthe actuator lever into the hole in the rotary disc.2.Pushthe lever down in the direction of the groove in the rotary disc.Designing Own ActuatorIf you decide to make your own actuator lever, the materials used should be stainless steel, piano wire, hard aluminum wire, etc.There are no restrictions on the tip shape or length of the actuator lever. However , if the lever is too long, improper switch resetting or contact chattering may occur. Therefore, the shape of lever as shown below is suitable.The appropriate value of dimension (l ) from the fulcrum is 50 mm.Use M3 mounting screws with plain washers or spring washers to mount the switch. Tighten the screws to a torque of 3 kg S cm (0.29 N S m).When soldering a lead wire to a terminal of the D2MC, use a solder -ing iron with a maximum capacity of 60 W and do not take more than 5 s to solder the lead wire, otherwise the characteristics of the D2MC may be altered.at more than 60 W may degrade the switch characteristics.Do not change the operating position by modifying the actuator .Microvoltage/current LoadFor details, refer to “General Information”.ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.To convert millimeters into inches, multiply by 0.03937. T o convert grams into ounces, multiply by 0.03527.Cat. No. B51-E1-6。

北方工具+设备1 2英寸空气扳手说明书

北方工具+设备1 2英寸空气扳手说明书
Air Connection
1.Remove the plastic cap from the rear of the motor housing. The cap is attached to the connection head. 2.You will need a union fitting (not included) before you can connect your Air Ratchet Wrench to an air compressor. Attach the Union fitting to the motor housing. Tighten the fitting. 3.Attach an Air coupler (not included) to the union fitting it desired. This is a useful accessory as it allows quick-coupling action when using a variety of tools with the same air compressor. Your Air Ratchet Wrench is now ready for use.
1 of 4
NOTE: READ ALL INSTRUCTIONSBEFORE USING THIS PRODUCT
ASSEMBLY
You Air Ratchet Wrench comes completely assembled. For information on parts, please refer to parts list & diagram on this manual.
Technical Specifications

超微 R221G1H 服务器 快速指南说明书

超微 R221G1H 服务器 快速指南说明书

R221G1H 服务器 快速指南资料版本:01 (2021-02-10) 东莞记忆存储科技有限公司非经本公司书面许可,任何单位和个人不得擅自摘抄、复制本文档内容的部分或全部,并不得以任何形式传播。

本文档提及的其他所有商标或注册商标,由各自的所有人拥有。

由于产品版本升级或其他原因,本文档内容会不定期进行更新。

除非另有约定,本文档仅作为使用指导,本文档中的所有陈述、信息和建议不构成任何明示或暗示的担保。

1 简介R221G1H 是一款高性能计算服务器产品,适用于高性能计算、数据库、Web 服务器、虚拟化以及企业基础应用和电信业务应用。

R221G1H 的主要技术参数如下所示,详细介绍请参见《R221G1H 服务器用户指南》。

2 前后面板3 指示灯和按钮前面板指示灯/按钮说明1231 网口连接状态指示灯2 硬盘 Fault 指示灯3 硬盘 Active 指示灯4 USB 3.0 接口5 NMI 按钮6 VGA 接口7 故障诊断数码管8 健康状态指示灯9 UID 按钮/指示灯 10 电源开关按钮/指示灯11 标签卡(含 SN 标签) 12 内置DVD 或可触控LCD 液晶屏(可选) 13硬盘14USB 2.0 接口1 IO 模组 12 数据传输状态指示灯3 连接状态指示灯4 数据传输状态指示灯5 连接状态指示灯6 IO 模组 27 IO 模组 38 电源模块扳手9 电源模块指示灯 10 电源模块 2 11 电源模块接口 12 电源模块 1 13 灵活网卡插卡(可选) 14 USB 3.0 接口 15 UID 指示灯 16 串口 17 管理网口 18 GE 电口 19VGA 接口20 10GE 电口 21 连接状态指示灯/数据传输状态指示灯 22速率指示灯23 10GE 光口24 速率指示灯25连接状态指示灯/数据传输状态指示灯— —4 安装∙ 拆卸和安装 R221G1H 前,必须先佩戴防静电腕带或防静电手套,以免损坏R221G1H 上的静电敏感器件。

海尔迪12012OME-PCI-1800H L数据采集卡说明书

海尔迪12012OME-PCI-1800H L数据采集卡说明书

D1-1ߜPCI Busߜ12-Bit 330 KHz A/D Converter ߜOME-PCI-1800H, OME-PCI-1800L: 16 Single-Ended/8 Differential Inputs, 2K Word FIFO ߜOME-PCI-1802H, OME-PCI-1802L:32 Single-Ended/16Differential Inputs, 8K Word FIFOߜ330 KSamples/s for Single Channel or Multiple Channels ߜTrigger Methods:Software Trigger, Pacer Trigger, External Trigger ߜExternal Triggers:Post-Trigger, Pre-Trigger,External Pacer Trigger ߜOME-PCI-1800L, OME-PCI-1802LProgrammable Low-Gain:0.5, 1, 2, 4, 8ߜ16 Digital Input and 16Digital Output Channels ߜOME-PCI-1800H,OME-PCI-1802H Programmable High-Gain: 0.5, 1, 5, 10, 50, 100, 500, 1000ߜTwo Optional 12-Bit IndependentProgrammable DACs; 2 MHz Throughput per Channel (Max)ߜ2.7M Word/High-Speed Data Transfer Rate ߜIncludes Software Development Kit ߜHalf-Size BoardThe OME-PCI-1800 Series is a family of high-performance data acquisition boards for the PCI bus. It features continuous, 330 kHz,gap-free data acquisition under DOS and Windows.The OME-PCI-1800 family has two 12-bit D/A output channels, 16 digital input channels, and 16 digital output channels. The OME-PCI-1800H and OME-PCI-1800L provide 16single-ended or 8 differential inputs.The OME-PCI-1802H and OME-PCI-1802L provide 32 single-ended or 16 differential inputs. The suffix “H” denotes ahigh-gain model and the “L” denotes a low-gain model. The boards feature advanced scanningfeatures. The scanning mechanism not only scans the different input channels at vastly different rates,but also at different gains. Even in multichannel scan mode, thesampling rates can be maintained at 330 KS/s.The OME-PCI-1800 Series also has some outstanding features,including:•Data transfer rate of digital I/O is up to 5.4 MB•Throughput of D/A is up to 2 MHz (max)•Three flexible external trigger modes such as post-trigger, pre-trigger, middle trigger•True “plug & play” under DOS and Windows •On-board FIFOHigh-Performance Analog and Digital I/O BoardsOME-PCI-1800H/L andOME-PCI-1802H/L: 330 KS/s 12-Bit SeriesOME-PCI-1800H,$759, shown smallerthan actual size$759Basic UnitD1-2D1ANALOG INPUT AND MULTIFUNCTION CARDS OME-DB-16P, $99, shown smaller than actual sizeOME-PCI-1800 Series System ExpansionSeveral daughter boards are available that can expand the analog and digital I/O capabilityof the OME-PCI-1800 Serieshigh-performance data acquisition boards. These include:OME-DB-1825, OME-DB-8225, OME-DB-8025, OME-DB-889D, OME-DB-16P, OME-DB-16R. OME-DB-889D 16-Channel Analog Multiplexer Board The OME DB-889D is an expansion multiplexer/amplifier board for use with OME-PCI-1800H/L boards. Each OME-DB-889D multiplexes 16 differential analog input channels into one analog input of the data acquisition board. The high-grade instrumentation amplifier providessoftware programmable gains of 0.5, 1, 5, 10, 50, 100, 500, and 1000. Thermocouple measurements are handled easily with the OME-DB-889D.The board includes cold-junction sensing and compensation circuitry that provides a scaling of 24.4 mV/°C.Biasing resistors are included for open thermocouple detection. The OME-DB-889D can be cascaded to a total of 128 channels of voltage measurements or 112 channels of thermocouple measurement.OME-DB-16P 16-Channel Isolated Digital Input Board The OME-DB-16P is a 16-channel isolated digital input daughter board for any of the OME-PCI-1802H/1802L/1800H/1800L/1602/ 1602F/1202H/1202L/1002H/1002L PCI-bus multifunction boards.The optically isolated inputs of the OME-DB-16P consist of a bi-directional OPTO-coupler witha resistor for current sensing. The OME-DB-16P can be used to sense DC signals from TTL levels up to 24 V and also a wide range of AC signals. The OME-DB-16P can also be used to isolate the computer from large common-mode voltages, ground loops and voltage spikes that often occur in industrial environments.OME-DB-16R 16-Channel Relay Output BoardThe OME-DB-16R 16-channel relay output board consists of 16 Form C relays for efficient switching of loads by programmed control. The OME-DB-16R can be used withany of the OME-PCI-1802H/1802L/1800H/1800L/1602/1602F/1202H/1202L/1002H/1002L PCI-busmultifunction boards. The relays areenergized by applying a 5 V signalto the appropriate relay channel onthe 20-pin flat cable connector.Sixteen annunciator LEDs, one foreach relay, light when their associatedrelay is activated. To avoidoverloading the PC’s power supply,this board provides a screw terminalconnection for a power supply.SoftwareDevelopment KitAll data acquisition boards aresupplied with a standard softwaredevelopment kit for Windows98/NT/2000/XP. The softwaredevelopment kit includes DLLfiles for programming in C, C++,or other high-level languages,and OCX filesfor Visual Basicor Active Xprogramming.LabVIEW driversare also included.SpecificationsANALOG INPUT SPECIFICATIONSInput Channels:OME-PCI-1802H/L, 32 SE/16 DiffOME-PCI-1800H/L, 16 SE/8 DiffResolution:12 bitsConversion Rate:330 KS/sInput Impedance:10,000 M1/6 pfOvervoltage Protection:±35 VAccuracy: 0.01% of reading, ±1 bitOn Board FIFO:OME-PCI-1800 H/L: 2KOME-PCI-1802 H/L: 8KOME-DB-16R, $149, shown smaller than actual sizeD1-3Ordering Example: OME-PCI-1802H 32-channel high-gain data acquisition board, OME-DB-8225/1screw terminal board and cable and OMEGACARE SM 1-year extended warranty for OME-PCI-1802H (adds 1 year to standard 1-year warranty), $849 + 89 + 80 = $1018.D/A OUTPUTS Channels:2Type:12-bit double buffers Linearity:0.06% FS Settling Time:0.4 msOutput Range:±5 or ±10 V Output Driving:±5 mA DIGITAL I/OInput:16 channels; TTL levels Input Low:V IL = 0.8 V max I IL = 4 mA Input High:V IH = 2 V min I IH = -20 μA maxOME-PCI-1800H, $759,shown smaller than actual sizeOME-DB-889D, $359, shown smaller than actual sizeOutput:16 channels; TTL levels Output Low:V OL = 0.5 V max I OL = 4 mA max Output High:V OH = 2.7 V min I OH = -400 μA maxTIMERInternal Pacer Timer:16-bit, 8 MHz input External Pacer Timer:16-bit, 8 MHz inputMachine Independent Timer:16-bit, 8 MHz inputGENERAL ENVIRONMENTAL Power Requirements : 5 V @ 350 mA (max) Operating Temperature:0 to 50°C (32 to 122°F)Storage Temperature:-20 to 70°C (-4 to 158°F)Humidity:0 to 90% RH non-condensingDimensions:190 L x 105 mm H (7.5 x 4.1")OMEGACARE SM extended warranty program is available for models shown on this page.Ask your sales representative for full details when placing an order. OMEGACARE SM covers parts, labor and equivalent loanersCANADA www.omega.ca Laval(Quebec)1-800-TC-OMEGA UNITED KINGDOM Manchester,England0800-488-488GERMANY www.omega.deDeckenpfronn,Germany************FRANCE www.omega.fr 088-466-342BENELUX www.omega.nl 0800-099-33-44UNITED STATES 1-800-TC-OMEGA Stamford,CT.CZECH REPUBLIC www.omegaeng.cz Karviná,Czech Republic596-311-899TemperatureCalibrators, Connectors, General Test and Measurement Instruments, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels,Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders, Relative Humidity Measurement Instruments, PT100 Probes, PT100 Elements,Temperature & Process Meters, Timers and Counters,Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples, Thermowells and Head and WellAssemblies, Transmitters, Thermocouple Wire, RTD ProbesPressure,Strain and ForceDisplacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and StrainMeasurements, Load Cells, Pressure Gauges, PressureReference Section, Pressure Switches, Pressure Transducers,Proximity Transducers, Regulators, Pressure Transmitters,Strain Gauges, Torque Transducers, ValvespH and ConductivityConductivity Instrumentation,Dissolved OxygenInstrumentation,Environmental Instrumentation,pH Electrodes and Instruments,Water and Soil Analysis InstrumentationHeatersBand Heaters,Cartridge Heaters,Circulation Heaters,Comfort Heaters,Controllers,Meters and SwitchingDevices,Flexible Heaters,General Test and Measurement Instruments,Heater Hook-up Wire,Heating Cable Systems,Immersion Heaters,Process Air and Duct,Heaters,Radiant Heaters,Strip Heaters,Tubular HeatersFlow and LevelAir Velocity Indicators,Doppler Flowmeters,LevelMeasurement,Magnetic Flowmeters,Mass Flowmeters,Pitot Tubes,Pumps,Rotameters,Turbine and Paddle Wheel Flowmeters,Ultrasonic Flowmeters,Valves,Variable Area Flowmeters,Vortex Shedding FlowmetersData AcquisitionAuto-Dialers and Alarm Monitoring Systems,Communication Products and Converters,Data Acquisition and Analysis Software,Data LoggersPlug-in Cards,Signal Conditioners,USB,RS232,RS485and Parallel Port Data Acquisition Systems,Wireless Transmitters and Receivers。

Dake 1-1 2C 手动螺栓杠杆压力钳说明书

Dake 1-1 2C 手动螺栓杠杆压力钳说明书

Dake CorporationPhone: 800.937.3253DAKE RATCHET LEVER ARBOR PRESSModel 1-1/2CINSTRUCTIONAL MANUALWARNING!Read and understand all instructions and responsibilities before operating. Failure to followsafety instructions and labels could result in serious injury.TABLE OF CONTENTSDAKE STANDARD LIMITED WARRANTY (2)RETURN & REFUND POLICY (4)DAKE STANDARD TERMS & CONDITIONS OF SALE (5)SPECIFICATIONS (6)SAFETY (6)HANDLE POSITION (7)OPERATION (7)MAINTENANCE (7)LUBRICATION (7)EXPLODED VIEW & PARTS LIST (8)EXPLODED PARTS VIEW (8)PARTS LIST (9)ORDERING INFORMATION (9)DAKE STANDARD LIMITED WARRANTYFinished MachinesDake warrants to the original purchaser the finished machine manufactured or distributed by it to be free from defects in material and workmanship under normal use and service within 1 year (12 months) from the delivery date to the end user.PartsDake warrants to the original purchaser the component part manufactured or distributed by it to be free from defects in material and workmanship under normal use and service within 30 days from the delivery date to the end user. The standard limited warranty includes the replacement of the defective component part at no cost to the end user.Sale of Service (Repairs)Dake warrants to the original purchaser the component part repaired by Dake Corporation at the manufacturing facility to be free from defects in material and workmanship under normal use and service within 90 days from the return date to the end user, as it pertains to the repair work completed. The standard limited warranty includes repair of the defective component part, at no cost to the end user. Warranty ProcessSubject to the conditions hereinafter set forth, the manufacturer will repair or replace any portion of the product that proves defective in materials or workmanship. The manufacturer retains the sole right and option, after inspection, to determine whether to repair or replace defective equipment, parts or components. The manufacturer will assume ownership of any defective parts replaced under this warranty.All requested warranty claims must be communicated to the distributor or representative responsible for the sale. Once communication has been initiated, the Warranty Representative at Dake Customer Service must be contacted for approval:Phone: (800) 937-3253Email: ****************************When contacting Dake, please have the following information readily available: - Model # - Serial # - Sales Order #Purchasers who notify Dake within the warranty period will be issued a Case number and/or a Return Material Authorization (RMA) number. If the item is to be returned per Dake’s request, the RMA number must be clearly written on the exterior packaging. Any item shipped to Dake without an RMA will not be processed.Warranty Exceptions:The following conditions are not applicable to the standard limited warranty:a) Part installation or machine service was not completed by a certified professional, and is not inaccordance with applicable local codes, ordinances and good trade practices.b) Defects or malfunctions resulting from improper installation or failure to operate or maintain theunit in accordance with the printed instructions provided.c) Defects or malfunctions resulting from abuse, accident, neglect or damage outside of prepaidfreight terms.d) Normal maintenance service or preventative maintenance, and the parts used in connection withsuch service.e) Units and parts which have been altered or repaired, other than by the manufacturer specificallyauthorized by the manufacturer.f) Alterations made to the machine that were not previously approved by the manufacturer, or thatare used for purposes other than the original design of the machine.RETURN & REFUND POLICYThank you for purchasing from Dake! If you are not entirely satisfied with your purchase, we are here to help.ReturnsAll Dake manufactured / distributed machines and parts include a 30-day return option. These policies are valid from the date of final shipment to the end user.To be eligible for a return, the item must be unused and in the same condition as received.All requested warranty claims must be communicated to the distributor or representative responsible for the sale. Once communication has been initiated, Dake Customer Service must be contacted for approval by the distributor or representative: Phone: (800) 937-3253 Email:****************************Once the return request has been approved by Customer Service, a representative will supply a Return Material Authorization (RMA) number. The returned item must have the provided RMA number clearly marked on the outside packaging. Any item received without an RMA number clearly visible on the packaging will not be processed. An RMA number can only be provided by the Dake Customer Service team and must be obtained prior to the return shipment.The item must be shipped and received back to Dake within 30 days from being issued the RMA number, or the return will be void and nonreturnable.RefundsOnce the item has been received and inspected for damages, a representative will notify the requestor referencing the provided RMA number.If the return is approved, a refund will be issued to the original method of payment, less a 20% restocking fee. The restocking fee may be waived if an order is placed at the time of return with like-value merchandise.Transportation costs are the responsibility of the end user and will not be credited upon return approval. Any item that is returned after the initial 30 days or has excessive/obvious use will not be considered for a full refund.DAKE STANDARD TERMS & CONDITIONS OF SALE All proposals and quotations for the original sale of our products are subject to the following terms and conditions:ACCEPTANCE OF ORDER: All orders are subject to acceptance by Dake at its main office in Grand Haven, Michigan.APPLICABLE LAWS: This quotation or acceptance shall be governed in all respects by the laws of the State of Michigan.CANCELLATION: We reserve the right to cancel and/or refuse to complete your order if, in our opinion, you have not established credit to promptly meet the payment terms of your order. Any cancellation from the Purchaser may be subject to a 10% cancellation fee for any of our standard machinery and/or component parts upon the discretion of Dake. All non-standard or special quotes will not be eligible for cancellation, nor returns.DELIVERY: The proposed shipment date is an estimate and is contingent upon causes bey ond Dake’s control. Under no circumstances shall Dake have any liability for loss of use or for any direct or consequential damages resulting from delay. All shipments from the Dake facilities are F.O.B.FREIGHT CLAIM: Lost or damage freight claims must b e submitted to Dake within thirty (30) days of shipment from Dake’s facility. If shipment for order was set up by the Purchaser, Dake is not liable to handle the freight claims.PERMITS AND COMPLIANCE: Dake shall not be responsible for obtaining any permits, inspections, certifications, or licenses required for the installation or use of the equipment. Dake makes no promise or representation that the equipment or any services to be furnished by Dake will conform to any federal, state, or local laws, ordinances, regulations, codes or standards. PRICES: Unless otherwise agreed to in writing, all prices are F.O.B. from our plants in Grand Haven, Michigan, Grand Prairie, Texas, and Riverside, CA. In any event, the quoted prices for component parts become invalid ten (10) days after date of quotation, and machinery may become invalid sixty (60) days after date of quotation. Unless otherwise specified in Dake’s quotation, installation services and final on-site adjustments are not included in the quotation.TAXES: Prices do not include taxes. If any sales, use or similar tax is payable to Dake in connection with any transaction or part thereof between the Purchaser and Dake with respect to goods delivered, the Purchaser will, upon demand, pay to Dake the amount of any such tax. If you are tax exempt, please include your exemption document when submitting your order.TERMS OF PAYMENT: Terms of payment are as stated in Dake’s quotation subject to credit approval by our home office. Dake will invoice Purchaser when the equipment is completed and ready for shipment. Payment terms run from invoice date. Purchaser may be required to issue a down payment before production of order, at the discretion of Dake Accounting. For credit card purchases, a 2% processing fee may be applicable to the order. The following states are exempt from the 2% processing fee: CA, CO, KS, OK, TX, FL, NY, CT, MA, and ME.WARRANTY: If, within a period of one (1) year from date of shipment of the original order, any part of any equipment sold by Dake is defective in material or workmanship and is so found after inspection by Dake, it will be replaced or repaired at the option of Dake, providing the equipment has been given normal and proper usage and is still the property of the original Purchaser. Purchased components such as Micro Drop mist system or the like, installed as a part of Dake equipment are warranted only to the extent of the original Manufacturer’s warranty. Dake is not responsible for any service work performed unless authorized in advance.THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN,ORAL, OR IMPLIED (INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULARPURPOSE). UNDER NO CIRCUMSTANCES SHALL DAKE BE LIABLE FOR ANY INCIDENTAL ORCONSEQUENTIAL DAMAGESSPECIFICATIONSSAFETYThis is the safety alert symbol. When you see this symbol on your press be alert to the potential for personal injury.Employer is responsible to perform a hazard/PPE assessment before work activity.Follow recommended precautions and safe operating practices.HANDLE POSITIONCAUTION: NEVER PULL THE PRESS HANDLE PAST THE HORIZONTAL POSITION! To avoid personal injury and damaging the press only pull until the handle is horizontal, then return the handle back up as far as it allows before bringing the handle back down. This ensures that the pawl fully engages with the gear teeth to prevent tooth damage and gear slippage that can cause harm to the machine and worker. Examples above show the ideal minimum and maximum handle positions.OPERATIONHandwheel: The handwheel (item 18) can be turned to raise or lower the ram to and from the workpiece without exerting force on the workpiece.Handle: The handle (item 10) can be used to lower the ram to exert force onto the workpiece. See safety instructions for more information on handle position.MAINTENANCELUBRICATION• Keep all working parts of the press well-oiled for easier operation.•Keep a light film of oil over the entire surface of the ram to prevent rust.EXPLODED VIEW & PARTS LISTEXPLODED PARTS VIEWPARTS LISTItem Part Name Part Number Qty1 Frame 69939 12 Socket Cap Screw (1/4”-20 x 2-3/4”)43422 13 Ram 191 14 Rest Pin 174 15 Tinners Rivet 43577 16 Brake Spring 108 17 Pawl Pin 175 18 Pawl 177 19 Lever Weight 176 110 Handle 179 111 Headless Set Screw (3/8”-16 x 5/8”)43589 412 Retaining Ring 67424 113 Spindle 180 114 Ram Cap Shim 69942 615 Screw Bolt (3/8”-16 x 1”)43328 616 Ram Cap 69940 117 Table Plate Assembly 700941 118 Handwheel 167 119 Retaining Ring 30577 120 Warning Label Tipping 79979 121 Warning Label – Ganged 300168 122 Warning Label – Pinch Point 87130 1Please contact factory for current prices.ORDERING INFORMATIONParts are available for direct purchase from Dake or through a distributor. When placing a parts order, you will need to provide the part number, name of part, and model number. All parts shipped F.O.B. Factory in Grand Haven, MI.。

MCL-1A型数字磁力仪

MCL-1A型数字磁力仪

感谢您使用MCL-2微机磁力仪MCL-2微机磁力仪是本公司在MCL-1A型数字磁力仪基础上新研制成功的,它是根据磁通门原理利用计算机智能控制的新型磁力仪,用于铁矿勘察及其地下铁质埋藏物。

由于该磁力仪操作十分简单,几分钟即能学会使用,大屏幕液晶可直接显示被测的磁场强度nT(伽码),同时显示温度,日期,电量(仪器电池),故特别适合于初学者使用。

由于该磁力仪内置计算机,具有自动线性校正,自动温度校正,24位高精度A/D转换器,可测量高达8万纳特强磁场,大屏幕显示器可显示磁场强度曲线,与电脑连接可进一步作数据处理和解释推断,故该磁力仪同样适用于专业物探、地质人员使用,是一种操作简便,具有较高分辨率和较高精度的磁力仪,性价比很高。

一、产品特点1.采用微处理器控制,能自动存储该测量点的磁场垂直分量、温度、时间,无需人工补偿,具有温度自动补偿功能。

2.大屏幕显示,全中文界面,自动显示磁场强度曲线,操作简单。

3.采用24位A/D转换器,分辨率高,测量范围宽。

4.自动电量显示。

5.背光显示,方便夜间操作。

二、主要技术指标测量范围:0-80000nT分辨率:1nT存储量:5120个点探头:硅油阻尼,转向差≤±10nT。

显示:160×128液晶,带背光。

电源: 1.3AH铅酸充电电池。

整机功耗: 80mA~110mA。

工作温度:-10ºC~+50ºC。

主机尺寸:225×180×80(MM)。

主机重量: 1 Kg探头尺寸: 125X70(MM)探头重量: 0.5 kg探杆尺寸: 1500(MM)探杆重量: 0.5 Kg三、仪器组成仪器由有主机、探头及探杆三部分组成,如图1所示。

图1 仪器组成四、工作原理仪器采用二次谐波原理设计。

磁敏元件被激励振荡器激励后,于次级线圈中产生二次谐波,经滤波,放大,相位整流,积分器输出到A/D转换器,由微处理器进行数据处理,存储,显示等。

D2SW-01H中文资料

D2SW-01H中文资料

127Watertight Miniature Basic SwitchD2SWA High-quality Watertight Miniature Basic Switch Conforms to IP67Monoblock construction assures high sealing capability and is ideal for dusty places or where water is sprayed.A wide operating temperature range of –40°C to 85°C is ideal for any operating environment.Ideal for the automobile, agricultural machinery,automatic vending machine, refrigerator, ice-manufacturing, bath equipment, hot-water supply,air conditioner, and factory machine industries,which require highly environment-resistive capabil -ities.RCD EV Note:1.The standard lengths of the lead wires (A V0.5f) of models incorporating them are 30 cm.2.EN61058-1 (IEC1058-1) approved by VDE.3.UL/CSA approved lead-wired models use UL/CSA approved lead wire. Model name changes from D2SW -j M to D2SW -j MS.Distributed by: Diamond Electronics LtdTel: +44(0)1477 500450 Fax: +44(0)1477 500656 Mail: sales@ Web: 128RatingsNote:1.The above current ratings are the values of the steady-state current.2.Inductive load has a power factor of 0.7 min. (AC) and a time constant of 7 ms max. (DC).mp load has an inrush current of 10 times the steady-state current.4.Motor load has an inrush current of 6 times the steady-state current.Approved StandardsUL (File No. E32667)/CSA (File No. LR21642)D2SW-3j : 3 A at 125 V AC, 2 A at 250 V AC D2SW-01j :0.1 A at 125 V AC, 0.1 A at 30 VDCVDE (Licence No. 85002)/EN61058-1 (IEC1058-1) ApprovedD2SW-01j H:0.1 A at 125 V ACContact Form(Red*)(Blue*)(Black*)*Indicates the color of the lead wire.Distributed by: Diamond Electronics LtdTel: +44(0)1477 500450 Fax: +44(0)1477 500656 Mail: sales@ Web: CharacteristicsNote:The operating speed value shown is for pin plunger models. For hinge lever models, this speed is for the plunger parts.VDE-approved Characteristics (EN61058-1)Distributed by: Diamond Electronics LtdTel: +44(0)1477 500450 Fax: +44(0)1477 500656 Mail: sales@ Web: 1291302.Every actual model number includes the code instead of j for the kind of terminals incorporated by the model.3.Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.Note:The following illustrations and dimensions are for models with soldered terminals. Refer to Terminals for models with tab (#110) and PCB terminals. The dimensions not described are the same as those of models with pin plungers.Pin PlungerD2SW-3jD2SW-01jHinge LeverD2SW-3L1jD2SW-01L1jSimulated Hinge Lever D2SW-3L3jD2SW-01L3j0.56.4±0.2PTOP2.97.710.1R0.81.63.21.8 dia.7.5±0.17.33.3±0.11.81.62.5 dia.±0.075.150.5519.8±0.215.5±0.218.7±0.29.5±0.18.5±0.214.5OPt = 0.3Stainlesssteel lever5.93.615.8OP FP5.93.6t = 0.3 Stainlesssteel lever2.35+0.1–0.052.35+0.1–0.05dia.FPR1.3Hinge Roller LeverD2SW-3L2jD2SW-01L2jt = 0.3 Stainlesssteel lever14.5OPFP5.94.8 dia. x 3.2Polyacetal rollerDistributed by: Diamond Electronics LtdTel: +44(0)1477 500450 Fax: +44(0)1477 500656 Mail: sales@ Web: 131Note:The following illustration and dimensions are for models with pin plungers. The dimensions and operating characteristics of the actua -tors of models incorporating them are the same as those of the actuators of models with both actuators and terminals.Common terminal (black)Vinyl insulatorNormally open terminal (blue)Stranded annealed copper wiresNormallyclosed terminal(red)2.99.27.5±0.11.8 dia.16.416.9300±10(5)6.4±0.221.25.159.5±0.12.35+0.1–0.052.35+0.1–0.05dia. holes2.5 dia.±0.070.73.3±0.12.910.16.6Three,2.88.7±0.25.159.5±0.115.5±0.219.8±0.22.150.56.4±0.2Three,1.2 dia.holes 7.33.3±0.11.81.62.9R0.81.63.26.4±0.20.519.8±0.28.5±0.25.159.5±0.115.5±0.218.7±0.27.23.3±0.10.81.28.8±0.25.151.859.5±0.1Three, 1.35 dia. to 1.5 holesPCB thickness t = 1.6 mm1.36.4±0.20.51.8±0.12.90.73.9Solder TerminalsTab Terminals (#110)PCB TerminalsPCB Mounting0.5519.8±0.216.1±0.2Distributed by: Diamond Electronics LtdTel: +44(0)1477 500450 Fax: +44(0)1477 500656 Mail: sales@ Web: 132Use two M3 mounting screws with spring washers to mount the switch. T ighten the screws to a torque of 0.23 to 0.26 N S m (2.3 to 2.7 kgf S cm).Mounting HolesWhen soldering a lead wire to a terminal of the D2SW , use a solder -ing iron with a maximum capacity of 60 W and do not take more than 5 s to solder the lead wire, otherwise the characteristics of the D2SW may be altered.Make sure that there is no icing when using the D2SW at low ambi -ent temperatures.OperationsMake sure that the switching object is perfectly separated from the actuator when the switch is not operated and the actuator is pressed appropriately by the switching object when the switch is operated.The switch should be set so that its stroke will be within the rated OT when the switch is operated.Install the switching object so that its moving direction is the same as that of the actuator .Handle D2SW models with pin plungers with care so that the sealing rubber parts around the pin plungers will not be damaged.Recommended conductor size for the 0.1 A-series solder terminal is A WG26 to 18 (0.13 to 0.83 mm 2).The D2SW was tested underwater and passed the following water -tightness tests, which however , does not mean that the D2SW can be used in the water .JIS C0920 (rules for testing the watertightness of electrical devices and materials), class 7 (watertightness test). Refer to the following illustration for the test method.IEC Publication 529, class IP67. Refer to the following illustration for the test method.Note:The object to be tested is left in the water for 30 minutes on condition that the distance between the surface of the water and the top of the object be 15 cm minimum and the distance between the surface of the water and the bottom of the object be 1 m minimum.ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.To convert millimeters into inches, multiply by 0.03937. T o convert grams into ounces, multiply by 0.03527.Cat. No. C97-E1-1Distributed by: Diamond Electronics LtdTel: +44(0)1477 500450 Fax: +44(0)1477 500656 Mail: sales@ Web: 。

D2MC-5F中文资料

D2MC-5F中文资料

138Low-torque Basic SwitchD2MCHighly Reliable Rotary-action Switch for Low Torque Operation0.5 A rated model (D2MC-01j ) employs crossbar alloy #1 contacts which exhibit unsurpassed contact reliability in very small load ranges.High-capacity 5 A Model (D2MC-5j ) employs silver contacts.Long life (10,000,000 mechanical operations min.)through use of a movable coil spring.Note:All the models listed here are supplied without actuator lever . If an actuator lever is required, please order separately by indicating the model name of the actuator lever .See Accessories.RatingsContact FormCharacteristicsNote:All the models listed here are supplied without actuator lever. If an actuator lever is required, please order separately by indicating the model name of the actuator lever.See“Accessories”.Approved StandardsUL (File No. E41515)CSA (File No. LR21642)D2MC-5j series:5 A, 125 V AC5 A, 250 V ACD2MC-01j series:0.5 A, 125 V AC0.5 A, 30 VDC139140Mechanical Life ExpectancyElectrical Life ExpectancyOvertravel (mm)Switching current (A)N u m b e r o f o p e r a t i o n s (x 10 )3N u m b e r o f o p e r a t i o n s (x 10 )3Without loadOperating frequency: 240 operations/minuteOvertravel (deg)Operating frequency: 20 operations/minute0.1 A 125 VAC0.5 A 125 VAC5 A 250 VAC2.Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.Snap-on MountingCounterclockwiseMounting HolesTwo 3.1 dia. mounting holes or M3 screw holes31#205 series quick connect terminals (0.8 t)18.21714.11027.817.5FPPT OT 9950.823.68.7±0.13.1±0.054±0.1 dia.0.8Operating direction3.1±0.05 dia.3.623.8±0.118±0.1PT FPOT Clockwise141CAA1M for Snap-on Mounting0.6 dia. stainless steel wire50±1In addition to the standard wire lever model shown here, various other levers are available upon request.Mounting Actuator Lever1.Insert the end ofthe actuator lever into the hole in the rotary disc.2.Pushthe lever down in the direction of the groove in the rotary disc.Designing Own ActuatorIf you decide to make your own actuator lever, the materials used should be stainless steel, piano wire, hard aluminum wire, etc.There are no restrictions on the tip shape or length of the actuator lever. However , if the lever is too long, improper switch resetting or contact chattering may occur. Therefore, the shape of lever as shown below is suitable.The appropriate value of dimension (l ) from the fulcrum is 50 mm.Use M3 mounting screws with plain washers or spring washers to mount the switch. Tighten the screws to a torque of 3 kg S cm (0.29 N S m).When soldering a lead wire to a terminal of the D2MC, use a solder -ing iron with a maximum capacity of 60 W and do not take more than 5 s to solder the lead wire, otherwise the characteristics of the D2MC may be altered.at more than 60 W may degrade the switch characteristics.Do not change the operating position by modifying the actuator .Microvoltage/current LoadFor details, refer to “General Information”.ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.To convert millimeters into inches, multiply by 0.03937. T o convert grams into ounces, multiply by 0.03527.Cat. No. B51-E1-6。

Ironton 1 2 英寸空气撬动器说明书

Ironton 1 2 英寸空气撬动器说明书

1/2" AIR IMPACT WRENCHOwner’s ManualWARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious personal injury.Item # 48247Thank you very much for choosing an Ironton product!For future reference, please complete the owner’s record below:Serial Number/Lot Date Code: ________________________________Purchase Date: ____________________________________________Save the receipt, warranty, and this manual. It is important that you read the entire manual to become familiar with this product before you begin using it.This 1/2in. Air Impact Wrench is designed for certain applications only. The distributor cannot be responsible for issues arising from modification or use of this product in an application for which it was not designed. We strongly recommend that this product not be modified and/or used for any application other than that for which it was designed. If you have questions about a particular modification or application, DO NOT use the product until you have first contacted the distributor to determine if the product can or should be modified or used in such an application.For technical questions, please call 1-800-222-5381.Intended Use (4)Technical Specifications (4)Important Safety Considerations (5)Safety Signs and Labels (8)Air Supply (9)Assembly (10)Lubrication (10)Before Each Use (11)Operating Instructions (12)After Each Use (13)Maintenance (13)Troubleshooting (13)Diagram (14)Parts List (15)Replacement Parts (17)Limited Warranty (18)This Ironton Air Impact Wrench is ideal for tire rotation, brake repairs, exhaust repairs, and lawn mower repairs.SAVE THESE INSTRUCTIONS∙DO NOT modify the tool in any way. Unauthorized modification may impair the function and/or safety of the tool and could affect the life of the tool. There are specific applications for which the tool is designed.∙Use the right tool for the job.DO NOT attempt to force a small equipment to do the work of larger industrial equipment. There are certain applications for which this equipment wasdesigned. It will do the job better and more safely at the capacity for which it was intended.DO NOT use this equipment for a purpose for which it was not intended.∙Industrial or commercial applications must follow OSHA requirements.WARNING: Operating the tool at pressures over the rated capacity may cause severe damage and/or personal injury. Do not exceed 90 PSI while operating the tool. Donot use an accessory rated at a lower maximum pressure than the tool itself.CAUTION: The air supply must be clean while operating the tool. Unclean airwill cause excessive wear, shorten the life of the tool, and may cause damage and/or personal injury.The illustration above shows an optimal setup that includes the air tool (1), quick connector (2), quick coupler (3), air hose (4), lubricator (5), regulator (6), filter (7), cut-off valve (8), and air compressor (9). Make sure that the air valve (or trigger) is in the “off” position before connecting to the air supply.∙Make sure that the air valve (or trigger) is in the “off” position before connecting to the air supply.∙Do not exceed an air pressure of 90 PSI.∙Drain the air tank daily. Water in the air line can damage the tool.∙Clean the air inlet filter weekly.∙Keep the hose away from heat, oil, and sharp objects. Check the hose for wear and make certain that all connections are secure before every use.Install a 1/4" air nipple (not included)1. Wrap the 1/4 in. air nipple with pipe thread seal tape (not included), and then thread it intothe air inlet on the air tool.2. Connect the 3/8 in. I.D. air hose (not included) to a quick-connect coupler (not included) andthen to the air nipple.3. Turn on the air compressor and set it to 90 PSI. Do not exceed the recommended airpressure of 90 PSI.4. Check the air connection for leaks.Install the socketTo install or remove a socket, slide the socket (1) on or off the square drive (2).Air tools require lubrication throughout their lifetime. The air motor and bearing use compressed air to power the tool. Compressed air contains moisture which may rust the air motor and other internal parts if the tool is not kept lubricated. Failure to lubricate the tool properly will dramatically shorten the life of the tool and will void the warranty.The tool must be manually lubricated before its initial use. If you are not using a lubricated air supply, the tool must be manually lubricated before and after each use, as well as after each hour of continual use.To manually lubricate the tool, add a few drops of pneumatic tool oil to the tool's air line connection.WARNING: Remove adjusting keys or wrenches before connecting the tool to the air supply or turning on the tool. A wrench or key that is left attached to a rotating part of the tool may cause personal injury.∙Inspect the tool for damage or excessive wear.∙If you are not using a lubricated air supply, lubricate the tool.∙Drain water from the air compressor tank and condensation from the air lines.∙Connect the air supply to the tool. Do not exceed the maximum air pressure of 90 PSI.∙To start the tool, press the trigger. To stop the tool, release the trigger (fig C).∙For reverse (R) rotation, press the speed control knob (1) on the left side of the tool (fig D).∙For forward (F) rotation, press the speed control knob (1) on the right side of the tool (fig E).∙Rotate the speed control knob (1) on the left side of the tool during reverse rotation to control the speed of the air flow as required (fig F).∙Rotate the speed control knob (1) on the right side of the tool during forward rotation to control the speed of the air flow as required (fig G).∙Disconnect the air supply from the tool.∙If you are not using a lubricated air supply, lubricate the tool.∙Store the tool.WARNING: To avoid risk of severe injury, disconnect the air supply from the tool before performing any maintenance, cleaning, or inspection.Maintain your tool. It is recommended that the general condition of any tool be examined before it is used. Keep your tool in good repair by adopting a program of conscientious repair and maintenance in accordance with the recommended procedures found in this manual. Keep all cutting tools sharp and clean. Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control. Keep handles dry, clean, and free from oil and grease.Cleaning. Use only soap and a damp cloth to clean your tool. Many household cleaners are harmful to plastics and other insulation. Never let liquid get inside the tool.If any abnormal vibrations or noise occurs, immediately turn the tool off and have the problem corrected before further use. Have necessary repairs made by qualified service personnel.∙For replacement parts and technical questions, please call Customer Service at 1-800-222-5381.∙Not all product components are available for replacement. The illustrations provided are a convenient reference to the location and position of parts in the assembly sequence.∙When ordering parts, the following will be required: Model Number, Serial Number/Lot Date Code, and Description.∙The distributor reserves the rights to make design changes and or improvements to product lines and manuals without notice.Northern Tool and Equipment Company, Inc. ("We'' or '"Us'') warrants to the original purchaser only ("You'' or “Your”) that the Ironton Air Tool product purchased will be free from material defects in both materials and workmanship, normal wear and tear excepted, for a period of one year from date of purchase. The foregoing warranty is valid only if the installation and use of the product is strictly in accordance with product instructions. There are no other warranties, express or implied, including the warranty of merchantability or fitness for a particular purpose. If the product does not comply with this limited warranty, Your sole and exclusive remedy is that We will, at our sole option and within a commercially reasonable time, either replace the product without charge to You or refund the purchase price (less shipping). This limited warranty is not transferable.Limitations on the WarrantyThis limited warranty does not cover: (a) normal wear and tear; (b) accessories both consumable and durable; (c) damage through abuse, neglect, misuse, or as a result of any accident or in any other manner; (d) damage from misapplication, overloading, or improper installation; (e) improper maintenance and repair; and (f) product alteration in any manner by anyone other than Us, with the sole exception of alterations made pursuant to product instructions and in a workmanlike manner.Obligations of PurchaserYou must retain Your product purchase receipt to verify date of purchase and that You are the original purchaser. To make a warranty claim, contact Us at 1-800-222-5381, identify the product by make and model number, and follow the claim instructions that will be provided. The product and the purchase receipt must be provided to Us in order to process Your warranty claim. Any returned product that is replaced or refunded by Us becomes our property. You will be responsible for return shipping costs or costs related to Your return visit to a retail store.Remedy LimitsProduct replacement or a refund of the purchase price is Your sole remedy under this limited warranty or any other warranty related to the product. We shall not be liable for: service or labor charges or damage to Your property incurred in removing or replacing the product; any damages, including, without limitation, damages to tangible personal property or personal injury, related to Your improper use, installation, or maintenance of the product; or any indirect, incidental or consequential damages of any kind for any reason.Assumption of RiskYou acknowledge and agree that any use of the product for any purpose other than the specified use(s) stated in the product instructions is at Your own risk.Governing LawThis limited warranty gives You specific legal rights, and You also may have other rights which vary from state to state. Some states do not allow limitations or exclusions on implied warranties or incidental or consequential damages, so the above limitations may not apply to You. This limited warranty is governed by the laws of the State of Minnesota, without regard to rules pertaining to conflicts of law. The state courts located in Dakota County, Minnesota shall have exclusive jurisdiction for any disputes relating to this warranty.Some dust created by power sanding, sawing, grinding, drilling, and other construction activities contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. Some examples of these chemicals are:∙lead from lead-based paints,∙crystalline silica from bricks and cement and other masonry products, and∙arsenic and chromium from chemically-treated lumber.Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well-ventilated area, and work with approved safety equipment, such as dust masks that are specially designed to filter out microscopic particles.Distributed byNorthern Tool and Equipment Company, Inc.Burnsville, Minnesota 55306Made in China。

欧诺克 DE2系列伺服驱动器 产品说明书

欧诺克 DE2系列伺服驱动器 产品说明书

DE2系列伺服驱动器使用说明书DE 2 series servo driver instruction manual深圳市欧诺克科技有限公司DE2系列伺服驱动器型号说明DE2系列驱动器规格汇总表驱动器型号供电电压连续电流 Amps(Arms) 峰值电流 Amps(Arms)6S 反馈类型外形尺寸重量DE2PC-09003-OPEA 3A (2.1A ) 6A (4.2A )208*118*40mm0.7kg5A (3.5A ) 10A (7A )DE2PC-09005-OPEA DE2PC-09010-OPEA 25A (17A )10A (7A )DE2PC-09016-OPEA 16A (11A )48A (33A )DE2PC-09024-OPEA 24A (16A )50A (35A )DE2PC-09040-OPEA 40A (28A ) 80A (56A )DE2PC-09050-OPEA 50A (35A ) 100A (70A )DE2PC-09075-OPEA 75A (52A ) 150A (105A )245*148*59mm 1.65kg DE2PC-090100-OPEA100A (70A ) 200A (140A )DE2PC-090150-OPEA 150A (105A ) 250A (175A )DE2PC-18024-OPEA 24A (16A ) 50A (35A )208*118*40mm 0.7kg 50A (35A ) 100A (70A )245*148*59mm1.65kgDE2PC-18050-OPEA DE2PC-18075-OPEA 75A (52A ) 150A (105A )18~135VDC DE2PC-135100-OPEA 100A (70A ) 200A (140A )18~90VDC 18~135/180VDC 增量式绝对值备注: 1.驱动器供电电压必须大于或者等于电机额定电压2.驱动器的额定电流必须大于或者等于电机的额定电流DE2PC-09012- OP E B系列DC/DE/DE2/BC/BC2/DH/BH制动单元B:带制动单元反馈E:光电增量式A/B 正交C:磁电增量式A/B 正交 A17:光电绝对值17bit C17:磁电绝对值17bit R:旋转变压器 H:数字霍尔 S:模拟量正余弦输入指令P:脉冲Hp:高速脉冲A:模拟量R:RS485 C:CANopen E:EtherCAT特殊功能OP:脉冲输出 OA:模拟量输出R:轮切 F:追剪 Z:攻丝机专用额定电流16:16Amps(11Arms) 50:50Amps(35Arms) 150:150Amps(105Arms)供电电压090:18-90VDC 180:18-180VDC 135:18-135VDC 220:220VAC 380:380VAC A:单相B:三相DE2系列端子定义DE2系列外形尺寸图LH4W型号L L1W H H1H2H3H4DE2PC-09003A~50A 20819840118101/4-4.8192DE2PC-09075A~150A 24523559148 8034.54-5.0229DE2PC-18024A 20819840118101/4-4.8192DE2PC-18050A~75A 245235591488034.54-5.0229DE2PC-135100AL 1H1H 3H WH4J3J4 J5 J6 J7 J8 SWJ1 & J11J10J2 & J91、产品简介:1.1概述DE2系列可编程智能伺服驱动器是一款通用、高性能、直流供电、结构紧凑的全数字伺服双驱动控制器。

MEDC Heat Detector HD1 - Exd IIC 技术手册说明书

MEDC Heat Detector HD1 - Exd IIC 技术手册说明书

Technical Manual for the Heat Detector HD1 – Exd IICPlease note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept responsibility for damage, loss or expense resulting from any error or omission. We reserve the right to make alterations in line with technical advances and industry standards.1.0 INTRODUCTIONThe HD1 heat Detector has been designed for use in flammable atmospheres and harsh environmental conditions. The marine grade alloy Exd version is suitable for use offshore or onshore, where light weight combined with corrosion resistance and strength is required.2.0 INSTALLATIONThe Heat Detector is mounted via 4 X Ø9mm fixing holes in feet on the base of the unit.The fixing holes have been designed to accept an M8 caphead screw or bolt.MEDC recommend the use of stainless steel fasteners.The Heat Detector will operate in any attitude2.1 Removing the CoverUnscrew the 4 x M6 cover fixing screws and lift the cover clear of the enclosure.See 2.2 Cable Termination.After cable termination has been completed the cover can be replaced and secured to the enclosure.2.2 Cable TerminationCable termination should be in accordance with specifications applying to the application. MEDC recommend that all cables and cores should be fully identified.Ensure that only the correct certified glands are used and that the assembly is shrouded and correctly earthed. All cable glands should be of an equivalent IP rating to that of the Heat Detector.In order to maintain the IP rating, the glands should be sealed to the Heat Detector using a sealing washer or sealing compound.The internal earth terminal must be used for the equipment grounding connection and the external terminal is for a supplementary bonding connection where local codes or authorities permit or require such connection.2.3 GeneralWhen installing and operating explosion-proof electrical equipment, the relevant national regulations for installation and operation (e.g. EN60079-14 and IEE Edition Wiring Regulations) must be observed. Ensure that all nuts, bolts and fixings are secure.Ensure that only the correct certified stopping plugs are used to blank off unused gland entry points. We recommend the use of ‘HYLOMAR PL32 COMPOUND’ on the threads of the stopping plugs in order to maintain the IP or NEMA rating of the unit.3.0 OPERATIONThe Heat Detector consists of a sealed element containing a single normally open (N.O.) thermal switch which operates at a fixed temperature. The sensor element is fully sealed and no attempt must be made to modify this in any way. Adjustment of the temperature setting is not possible.4.0 MAINTENANCEDuring the working life of the Heat Detector it should require little or no maintenance. However, if abnormal or unusual environ-mental conditions occur due to plant damage or accident etc., then visual inspection is recommended.If a fault should occur, then the unit can be repaired by MEDC.UNDER NO CIRCUMSTANCES SHOULD ANY ATTEMPT BE MADE TO EITHER UNSCREW THE HEAT DETECTOR ELEMENT FROM THE ENCLOSURE OR GAIN ACCESS TO THE INSIDE OF THE HEAT DETECTOR ELEMENT. EITHER OF THESE ACTIONS WILL RESULT IN THE ASSEMBLY BECOMING UNSAFE FOR USE IN A POTENTIALLY EXPLOSIVE ATMOSPHERE.If you have acquired a significant quantity of Heat Detectors, then it is recommended that spares are also made available, (please discuss your requirements with MEDC’s Technical Sales Engineers).5.0 CERTIFICATIONCertified to EN60079-0:2006, EN60079-1:2004, EN62141-0:2006, EN61241-1:2004Exd IIC tD A21 IP6X T85°C (Tamb = -20°C to +55°C).ATEX Certificate Number: Baseefa 08ATEX0320The ATEX certificate and the product label carry the ATEX group and category marking: II 2GDWhere:signifies compliance with ATEX signifies suitability for use in surface industries2 signifies suitability for use in a zone 1 areaG signifies suitability for use in the presence of gasesD signifies suitability for use in the presence of dustA21 signifies suitability for use in the presence of dust in a zone 21 areaThe product label also carries the following mark:This signifies unit compliance to the relevant European directives, in this case 2014/34/EU , along with the number of the notified body issuing the EC type examination certificate.6.0 FUNCTIONAL SAFETYIntroductionThe HD1 Heat Detector has been designed for use in flammable atmospheres and harsh environmental Conditions. The marine grade alloy (Exd version) or Glass Reinforced Polyester (Exem and Exia versions) are suitable for use offshore or onshore, where light weight combined with corrosion resistance and strength is required.The safety function of the Heat Detector is to detect when a predefined temperature is reached.Under No fault (Normal) operating conditions the Heat Detector contacts are normally openUnder fault conditions the failure mode of the Heat Detector is a failure to activate when a predefined temperature is reached. For the failure rate associated with this failure mode please refer to the table below. Assessment of Functional SafetyThe HD1 Heat Detector is intended for use in a safety system conforming to the requirements of IEC61508 Sira Test & certification has conducted a failure Modes Effect and Diagnostic Analysis (FMEDA) of the HD1 Heat Detector against the requirements of IEC61508-2 using a proof test interval of 8760 hours.The HD1 Heat Detector is classed as a Type A device.Conditions of Safe Use1.The user shall comply with the requirements given in the manufacturer’s user documentation (SafetyManual) in regard to all relevant functional safety aspects such as application of use, installation,operation, maintenance, proof tests, maximum ratings, environmental conditions, repair, etc;2.Selection of this equipment for use in safety functions and the installation, configuration, overallvalidation, maintenance and repair shall only be carried out by competent personnel, observing all the manufacturer’s conditions and recommendations in the user documentation.3.All information associated with any field failures of this product should be collected under adependability management process (e.g., IEC 60300-3-2) and reported to the manufacturer.4.The unit should be tested at regular intervals to identify any malfunctions; in accordance with this safetymanual.MEDC Ltd, Colliery Road, Pinxton, Nottingham NG16 6JF, UK.Tel: +44 (0)1773 864100 Fax: +44 (0)1773 582800Sales Enq. Fax: +44 (0)1773 582830 Sales Orders Fax: +44 (0)1773 582832 MEDC Stock No. E-mail:**************Web: TM228-ISS C。

Omron D2LS-@ 1 超小型基本开关说明书

Omron D2LS-@ 1 超小型基本开关说明书

1Compact Surface-mounting Switches ideal for applications requiring long durabilityHigh Force type also available·High operating force type also achieving long durability (OF: 1.2 N, Durability: 5,000,000 operations)·Compact size 8.6 × 4.8 × 3.0 mm (W × D × H) contributing to down-sizing of module ·Clear click feeling·Embossed taping package for automatic mountingRoHS CompliantModel Number LegendContact Form●SPST-NOList of Models*Products are packed with embossed tape.Contact SpecificationsRatingsNote:The rating values apply under the following test conditions.Ambient temperature: 20 ± 2°C Ambient humidity: 65 ± 5%RHOperating frequency: 30 operations/minCharacteristicsNote:The data given above are initial values.*1.The values are at Free Position and Total Travel Position values.Close or open circuit of the contact is 1ms max.*2.For testing conditions, consult your OMRON sales representative.D2LS -@1Operatin g Force (OF)1: 1.2±0.4 N {122±41 gf}2: 0.6±0.2 N {61±20 gf}COM N OOperating Force (OF)Button colorModel Minimum packing unit *1.2 N {122 gf}WHITE D2LS-112,000 pcs.0.6 N {61 gf}BLUED2LS-21ContactSpecificationCrossbar MaterialSilver Gap (standard value)0.4 mm Minimum applicable load (reference value)3 VDC 15 µARated voltageResistive load6 VDC1 mAOperating speed 1 mm to 500 mm/s Operatiing frequency Mechanical/Electrical300 operations/min max.Insulation resistance100 M Ω min. (at 500 VDC) Contact resistance (initial value)100 m Ω max.Dielectric strength Between terminals of same polarity 600 VAC 50/60 Hz 1 minVibration resistance *1Malfunction 10 to 55 Hz, 1.5 mm double amplitude Shock resistance *1Destruction 1,000 m/s 2 max.Malfunction300 m/s 2 max.Durability *2Mechanical/Electrical 5,000,000 operations min. (at 300 ops./min.)Degree of protectionIP40Ambient operating tamperature –25 to +85°C (at 60%RH Max.) (with no icing or condensation) Ambient operation humidity 85%RH max. (for +5 to +35°C)WeightApprox. 0.16 g2D2LSUltra Subminiature Basic SwitchDimensions (Unit: mm) / Operating CharacteristicsNote:Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.Packaging Specifications(Unit: mm)PCB pad dimensions (reference)(TOP VIEW)ModelOperating Characteristics D2LS-11D2LS-21Operating ForceReleasing ForceOFRF min.1.2 ± 0.4 N {122 ± 41 gf}0.15 N {15 gf}0.6 ± 0.2 N {61 ± 20 gf}0.15 N {15 gf}Overtravel Movement Differential OT min.MD max.0.1 mm 0.12 mm Operating Position Free PositionOP FP3.2 ± 0.2 mm 3.5 ± 0.2 mmD2LS-11D2LS-21Drawin g Standard package Qty: 2,000 pcs./reel1.5 -0.13D2LSUltra Subminiature Basic SwitchPrecautionsRefer to General Information.Use the Switch within the rated voltage and current ranges, oth-erwise the Switch may have a shortened durability, radiate heat,or burn out. This partic ularly applies to the instantaneous volt-ages and currents when switching.●Soldering·General PrecautionsBefore soldering the Switch on a multilayer PCB, test to con-firm that soldering can be performed properly. Otherwise the Switch may be deformed by the soldering heat on the pattern or lands of the multilayer PCB.Do not solder the Switch more than twice, including rectifica-tion soldering. An interval of five minutes is required between the first and the second soldering.·Reflow Soldering (Surface Mounting)Solder the terminals within the heating curve shown in the fol-lowing diagram.The peak temperature may vary depending on the reflow bath used. Confirm the conditions beforehand.·Manual SolderingSoldering temperature: 350°C max. at the tip of the soldering ironSoldering time: 3 s max.●WashingThe Switch is not sealed, and cannot be washed. Doing so will cause the washing agent, together with flux or dust particles on the PCB, to enter the Switch, resulting in malfunction.●Application EnvironmentDo not use the Switch in locations that are subject to toxic gas, silicon, excessive dust, excessive dirt, high temperatures, high humidity, sudden temperature changes, water splashes, or oil splashes.Otherwise, damage resulting by faulty contact of the Switch contacts, corrosion, or other causes, or other functional faults may occur.CautionsCorrect Use• Application examples pro v ided in this doc u ment are for reference only. In act u al applications, confirm e qu ipment f u nctions and safety b efore u sing the prod u ct.• Cons u lt yo u r OMRON representati v e b efore u sing the prod u ct u nder conditions w hich are not descri b ed in the man u al or applying the prod u ct to n u clear control systems, railroad systems, a v iation systems, v ehicles, com bu stion systems, medical e qu ipment, am u sement machines, safety e qu ipment, and other systems or e qu ipment that may ha v e a serio u s infl u enc e on li v es and property if u sed improperly. Make s u re that the ratings and performanc e c harac teristic s of the prod u c t pro v ide a margin of safety for the system or e qu ipment, and b e s u re to pro v ide the system or e qu ipment w ith do ub le safety mechanisms.Cat. No. B122-E1-021014(1213)Note: Do not use this document to operate the Unit.OMRON CorporationElectronic and Mechanical Components CompanyContact: /ecb。

纳伊尔(Nailor)产品:类型火阻挡设备安装说明书

纳伊尔(Nailor)产品:类型火阻挡设备安装说明书

Page 1.0501/14 IOM-FDINSTINSTALLATION INSTRUCTIONSCURTAIN TYPE FIRE DAMPERS • STANDARD & WIDE FRAME 1 1/2 & 3 HR. LABEL • VERTICAL & HORIZONTAL MOUNT MODEL SERIES: (D) 0100, 0300, (D) 0500Page 1 of 4Dimensions are in inches (mm).TYPE CTYPE B STYLE 21" (25) MINIMUM (SEE NOTE 5)TYPE B PLAIN "S" SLIP HEMMED "S" SLIP DOUBLE "S" SLIP STANDING "S" SLIP (ALT. BAR)INSIDE SLIP JOINTSTANDING "S" SLIP (ANGLE REINFORCED)STANDING "S" SLIP(BAR REINFORCED)STANDING "S" SLIPFLAT DRIVE SLIPb. Round and oval duct may be attached to the round or oval collar which is part of thedamper/sleeve in the following manner:•Duct diameters 22" (559) and smaller must use three #10 sheet metal screws equally spaced around the circumference.•Duct diameters over 22" (559) up to and including 36" (914) may use five #10 sheet metal screws equally spaced around the circumference.•Duct diameters larger than 36" (914) wide or diameter may use eight #10 sheet metal screws equally spaced around the circumference.In addition:•A maximum of two #10 sheet metal screws on each side and on the bottom, located in the center of the slip pocket and penetrating both sides of the slip pocket may be used.•One of the above connections on the top and bottom joints with flat drive slip connections on the side joints may be used for dampers up to 20" (508) in height.QUALIFICATIONS:•Meets all the requirements of UL 555 and CAN/ULC-S112.•Meets the requirements for NFPA 80,90A and 101, as well as IBC and NBC (Canada) building codes.•California State Fire Marshal Listing No. 03225-0935:0113.•City of New York Board of Standards and Appeals. Cal. No. 460-88-SA.NOTES:1.Installation shall be in accordance with the appropriate requirements of the National Fire Protection Association Standard NFPA 90A latest edition.2.Damper Sleeve: Sleeve thickness must be equal to or thicker than the duct connected to it. Sleeve gauge requirements are listed in the SMACNA Fire, Smoke and Radiation Damper Installation Guide for HVAC Systems and in NFPA 90A. If a break-away style duct/sleeve connection is not used, damper sleeves up to 36" wide by 24"(914 x 610) high of not less than 16 gauge (1.61) coated steel, or larger sleeves of not less than 14 gauge (1.99) thick coated steel may be attached to the duct with screws or other types of mechanical fasteners. The maximum sleeve thickness for such rigid joints is 10 gauge (3.51) for coated steel.The connecting duct shall not be continuous thru the wall or floor opening but shall terminate at the sleeve. Sleeves shall extend a maximum of 6" (152) on either side of the wall or floor opening or 16" (406) on one side when incorporating a factory installed access door.3. Break-away duct/sleeve connections:a. Rectangular ducts must use one or more of the following connections if the gauge is less than the requirement in note 2 for rigid connections:Page 1.0511/14 IOM-FDINSTPage 2 of 4Dimensions are in inches (mm).Note:When optional sealing of these break-away connections is desired, the duct sealant shall be PA2084T Duct Sealant by Precision or water based DP1010 by Design Polymetrics.c. For the use of approved alternative Ductmate or TDC/TDF break-away connections, refer to the supplements noted on page 4.4.Damper/sleeve attachment: Damper shall be secured to sleeve with 1/4" (6) long welds, spot welds, 3/16" (4.76) steel rivets, 1/4" (6.35)dia. bolts and nuts, #8 sheet metal screws, or 3/16" (4.76) dia. buttonloks on both sides at 6" (152) on center and a maximum of 2" (51) from the corners of the damper on all four sides. For field assembled sleeves, the inner dimensions of the sleeve shall be equal to the outer dimensions of the damper.5.Retaining angles shall be a minimum of 1 1/2" x 1 1/2" x 16 gauge (38 x 38 x 1.61) for dampers up to 90" (2286)in width and up to 90"(2286) in height. For dampers exceeding these dimensions, the angles shall be a minimum of 2" x 2" x 10 gauge (51 x 51 x 3.51). Secure the retaining angles to the sleeve with 1/2" (12.7) long welds, 1/4" (6.35) dia. bolts and nuts, 3/16" (4.76) dia. steel rivets or #8 sheet metal screws 8" (203) on center and 2" (51) maximum from corner of sleeve on all four sides. The retaining angles must lap the structural opening by 1" (25.4) minimum. When the ductwork terminates at the wall or floor, the retaining angles may be turned inwards, providing the opening size is increased by an amount equal to twice the combined thickness of the angle and the height of the screw or bolthead to maintain the required expansion clearance. Field fabricated retaining angles are not to be mechanically fastened at the corners.6.Expansion clearance between the sleeve and wall or floor shall be a minimum of 1/8" per foot (3.18 per 305) of width or height of the sleeve.The maximum size of the opening shall be 2" (50.8) larger in either dimension than the allowable minimum size. For example; a sleeve dimension of 36" x 36" (914 x 914) shall have an opening size of 36 3/8" x 36 3/8" (924 x 924) minimum and 38 3/8" x 38 3/8" (975 x 975) maximum.7.The maximum Type A fire damper sizes are as follows:Model SeriesSingle Section Multiple Section 0100StaticVertical (1 1/2 hr. label)60" x 60" (1524 x 1524)120" x 120" (3048 x 3048)Horizontal(1 1/2 hr. label)60" x 60" (1524 x 1524)102" x 60" (2591 x 1524)0300Static Vertical(1 1/2 hr. label)60" x 48" (1524 x 1219)–Horizontal(1 1/2 hr. label)48" x 48" (1219 x 1219)–D0100Dynamic Vertical(1 1/2 hr. label)36" x 36" (914 x 914)36" x 48" (914 x 1219) OR 72" x 24" (1829 x 610)Horizontal (1 1/2 hr. label)24" x 24" (610 x 610)–0500Static Vertical (3 hr. label)48" x 48" (1219 x 1219)108" x 72" (2743 x 1829)Horizontal (3 hr. label)36" x 36" (914 x 914)72" x 36" (1829 x 914)0540StaticVertical(3 hr. label)60" x 48" (1524 x 1219) or –24" x 60" (610 x 1524)D0500Dynamic Vertical(3 hr. label)36" x 36" (914 x 914)36" x 48" (914 x 1219) OR 72" x 24" (1829 x 610)Horizontal(3 hr. label)24" x 24" (610 x 610)–Type B and C dampers have the same overall damper size but the connecting ducts are smaller due to the B or C enclosures. See Type B and Type C specification drawings for maximum duct sizes.Maximum individual sections not to exceed 34" x 60" (864 x 1524).Maximum individual sections not to exceed 36" x 36" (914 x 914).Maximum individual sections not to exceed 24" x 24" (610 x 610), up to 48" x 24" (1219 x 610). Assemblies larger than 48" x 24" (1219 x 610) will be made up of individual sections not to exceed 18" x 24" (457 x 610).8.Multiple Section Assemblies. Individual dampers may be joined together to make multiple section damper assemblies (see Figure 1). The frames shall be fastened together using 1/4" (6) long welds, 3/16" (4.76) steel rivets, 1/4" (6.35) bolts and nuts, #8 sheet metal screws or 3/16"(4.76) buttonloks on both sides of the damper at 6" (152) max. on center and 2" (51) max. from the corner of the damper on all 4 sides. The following additional requirements shall be met:Vertical dampers, 1 1/2 hr. label over 84" (2134) in width require a 12 ga. x 4 1/4" (2.75 x 108) wide steel mullion plate placed between adjacent vertical damper frames and the frames fastened together through this with 1/4" (6.35) bolts and nuts, 12" (305) max. on center. Dampers over 84"(2134) in height require a full length 2" x 2" x 10 ga. (51 x 51 x 3.51) steel angle bolted along horizontal joints on both sides of the assembly using 1/4" (6.35) bolts and nuts, 12" (305) max. on center (see Figure 2).Horizontal dampers, 1 1/2 hr. label over 84" (2134) wide require a 14 ga. x 4 1/4" (1.99 x 108) wide steel mullion plate placed between adjacent damper frames and the frames fastened together through this using 1/4" (6.35) bolts and nuts, 1/4" (6)long welds or #8 sheet metal screws,4" (102) max. on center.Vertical dampers, 3 hr. label multiple sections require a 16 ga. x 6" (1.61 ga. x 152) wide "Z" mullion with 7/8" (22) flanges shall be placed between any horizontal joints (see Figure 3). The frames shall be joined together using 3/16" (4.76) bolts and nuts, 1/4" (6)long welds or #8sheet metal screws, 6" (152) max. on center.************************Page 1.0521/14 IOM-FDINSTPage 3 of 4Dimensions are in inches (mm).TWO S TEELSFigure 1.Fastening of damper frames (see note 8).1 1/2 hr. label vertical installationover 84" x 84" (2134 x 2134) (see note 8)."Z"3 hr. label vertical installation multiple section (see note 8).Page 1.0531/14 IOM-FDINST "C o m p l e t e A i r C o n t r o l a n d D i s t r i b u t i o n S o l u t i o n s."w w w.n a i l o r.c o mPage 4 of 4Dimensions are in inches (mm).Calgary, Canada Tel: 403-279-8619Fax: 403-279-5035Houston, TexasTel: 281-590-1172Fax: 281-590-3086Toronto, Canada Tel: 416-744-3300Fax: 416-744-3360Las Vegas, Nevada Tel: 702-648-5400Fax: 702-638-04009.In cases where the openings are larger than specified in note 7, a UL tested and qualified steel mullion must be provided between assemblies (refer to supplementary installation sheet FDSMINST).IMPORTANTDO NOT CAST DAMPER IN PLACE.DO NOT FASTEN RETAINING ANGLES OR DAMPER DIRECTLY TO WALL OR FLOOR.DO NOT INSTALL DAMPER OUT OF SQUARE OR OUT OF FLAT.VERTICAL MOUNTING SHOWN ON MASONRY WALL.FOR INSTALLATION IN DRYWALL FRAMING, SEE DOC. FDSWSFINST.HORIZONTAL MOUNTING SIMILAR FOR MASONRY FLOOR.REFER TO THE APPROPRIATE NAILOR INSTALLATION INSTRUCTION SUPPLEMENTS FOR THE FOLLOWING SPECIAL REQUIREMENTS:STEEL MULLIONS (for dampers in oversized wall openings)FDSMINST SINGLE SIDED RETAINING ANGLES FDSSRAINST STEEL AND WOOD STUD FRAMING FDSWSFINST CAVITY SHAFT WALL PARTITIONS FDCSWINST FLANGED TYPE ALTERNATIVE BREAKAWAY CONNECTIONS FDFABC TDC/TDF FLANGED DUCT CONNECTION FDTDCFINST QUICK-SET RETAINING ANGLES FDQSRA。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

138
Low-torque Basic Switch
D2MC
Highly Reliable Rotary-action Switch for Low Torque Operation
0.5 A rated model (D2MC-01j ) employs crossbar alloy #1 contacts which exhibit unsurpassed contact reliability in very small load ranges.High-capacity 5 A Model (D2MC-5j ) employs silver contacts.
Long life (10,000,000 mechanical operations min.)
through use of a movable coil spring.
Note:
All the models listed here are supplied without actuator lever . If an actuator lever is required, please order separately by indicating the model name of the actuator lever .See Accessories.
Ratings
Contact Form
Characteristics
Note:All the models listed here are supplied without actuator lever. If an actuator lever is required, please order separately by indicating the model name of the actuator lever.
See“Accessories”.
Approved Standards
UL (File No. E41515)
CSA (File No. LR21642)
D2MC-5j series:5 A, 125 V AC
5 A, 250 V AC
D2MC-01j series:0.5 A, 125 V AC
0.5 A, 30 VDC
139
140
Mechanical Life Expectancy
Electrical Life Expectancy
Overtravel (mm)Switching current (A)
N u m b e r o f o p e r a t i o n s (x 10 )
3N u m b e r o f o p e r a t i o n s (x 10 )
3Without load
Operating frequency: 240 operations/minute
Overtravel (deg)
Operating frequency: 20 operations/minute
0.1 A 125 VAC
0.5 A 125 VAC
5 A 250 VAC
2.Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Snap-on Mounting
Counterclockwise
Mounting Holes
Two 3.1 dia. mounting holes or M3 screw holes
31
#205 series quick connect terminals (0.8 t)
18.2
1714.1
10
27.817.5FP
PT OT 9
9
5
0.8
2
3.68.7±0.13.1±0.05
4±0.1 dia.
0.8
Operating direction
3.1±0.05 dia.3.6
23.8±0.118±0.1
PT FP
OT Clockwise
141
CAA1M for Snap-on Mounting
0.6 dia. stainless steel wire
50±1
In addition to the standard wire lever model shown here, various other levers are available upon request.
Mounting Actuator Lever
1.Insert the end of
the actuator lever into the hole in the rotary disc.
2.Push
the lever down in the direction of the groove in the rotary disc.
Designing Own Actuator
If you decide to make your own actuator lever, the materials used should be stainless steel, piano wire, hard aluminum wire, etc.There are no restrictions on the tip shape or length of the actuator lever. However , if the lever is too long, improper switch resetting or contact chattering may occur. Therefore, the shape of lever as shown below is suitable.
The appropriate value of dimension (l ) from the fulcrum is 50 mm.
Use M3 mounting screws with plain washers or spring washers to mount the switch. Tighten the screws to a torque of 3 kg S cm (0.29 N S m).
When soldering a lead wire to a terminal of the D2MC, use a solder -ing iron with a maximum capacity of 60 W and do not take more than 5 s to solder the lead wire, otherwise the characteristics of the D2MC may be altered.
at more than 60 W may degrade the switch characteristics.Do not change the operating position by modifying the actuator .
Microvoltage/current Load
For details, refer to “General Information”.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. T o convert grams into ounces, multiply by 0.03527.