国网企标_元件
Q GDW 730-2012 国家电网企标 12kV固体绝缘环网柜 技术条件
ICS29.240Q/GDW 国家电网公司企业标准Q/GDW730—201212kV固体绝缘环网柜技术条件Specifications for12kV solid-insulated ring main units2012-03-02发布2012-03-02实施国家电网公司发布Q/GDW730—2012目次前言··································································································································································II1范围·····························································································································································12规范性引用文件··········································································································································13术语和定义··················································································································································24正常使用条件和特殊使用条件···················································································································25设备型号和定义··········································································································································26额定值·························································································································································27设计与结构··················································································································································48型式试验······················································································································································89出厂试验·····················································································································································1210交接试验···················································································································································1311选用导则···················································································································································1412查询、投标和订货时提供的资料············································································································1513运输、贮存、安装、运行和维护规则····································································································1514安全··························································································································································17编制说明··························································································································································18IQ/GDW730—2012II前言固体绝缘环网柜是国家电网公司重点推广的新技术成果之一。
国家电网公司企业标准
国家电网公司企业标准1国家电网公司企业标准SG/T XXXXX.XX电网企业门户系统认证设计和管理规范Portal authentication for electric grid enterpriseDesign and management specifications(初稿)YYYY-MM-DD发布YYYY-MM-DD实施国家电力公司信息化工作办公室发布SG/T XXXXX.X2 目次1范围(5)2规范性引用文件(5)3术语和定义(5)4电网企业门户系统认证框架(7)4.1认证的概念(7)4.2认证的方式方法(8)4.2.1故障转移cookie (8)4.2.2CDSSO 标识标记(8)4.2.3客户机端证书(9)4.2.4表单认证(用户名和密码)(9) 4.2.5SPNEGO(Kerberos)(9)4.2.6基本认证(用户名和密码)(9) 4.2.7HTTP 头(9)4.2.8IP 地址(10)4.3电网企业认证的范围(10)4.4电网企业认证实施的步骤(11)5认证标准的具体内容(11)5.1用户安全域体系的建立(11)5.2用户身份的统一管理(12)5.3统一的身份认证和授权(12)5.4用户身份ID编码规则(13)5.4.1定义原则:(13)5.4.2用户ID编码遵循以下原则:(13) 5.5用户身份认证技术规范(13)5.5.1认证过程简介(13)5.5.2认证过程概述(14)5.5.3受支持的会话数据类型(14)5.5.4受支持的认证方法(14)5.5.5HTTP头认证管理(15)5.5.6数字证书认证管理(16)5.6用户管理流程(16)5.6.1总体流程(17)5.6.2添加用户(17)5.6.3删除用户(19)5.6.4信息变动—不跨域(19)5.6.5信息变动—跨域调动(19)5.6.6管理员变更――超级管理员变更(20) 5.7统一域名管理(20)5.8附录(21)SG/T XXXXX.X6认证管理工具(21)7本标准的更新和管理(22)3SG/T XXXXX.X4前言本部分由国家电网公司信息化工作办公室提出并归口。
国家电网公司总部_2016年配网标准化物资固化技术规范书_10kV箱式变电站,欧式,硅钢片,普通,有环网柜
国家电网公司集中规模招标采购国家电网公司总部配网标准化物资固化技术规范书10kV箱式变电站,欧式,硅钢片,普通,有环网柜。
终端型,GRC外壳,S13,低压组屏(9906-500003056-00142)招标文件2016年6月目录第1部分通用技术规范 (2)1 范围 (2)2 规范性引用文件 (2)3 术语和定义 (3)4 总则 (3)5 结构及其他要求 (6)7 技术服务、工厂检验和监造 (8)第2部分:专用技术规范 (10)1 标准技术参数 (10)2 主要组部件材料表 (15)3 使用环境条件表 (16)4 附图 (18)第1部分通用技术规范1 范围本部分规定了10kV箱式变电站招标的总则、技术参数和性能要求、试验、包装、运输、交货及工厂检验和监造的一般要求。
本部分适用于10kV箱式变电站招标。
2规范性引用文件下列文件对于本文件的应用是必不可少的。
凡是注日期的引用文件,仅注日期的版本适用于本文件。
凡是不注日期的引用文件,其最新版本适用于本文件。
GB 311.1 绝缘配合第1部分:定义、原则和规则GB 1094.1 电力变压器第1部分:总则GB 1094.2 电力变压器第2部分:温升GB 1094.3 电力变压器第3部分:绝缘水平、绝缘试验和外绝缘空气间隙GB 1094.4 电力变压器第4部分:电力变压器和电抗器雷电冲击和操作冲击试验导则GB 1094.5 电力变压器第5部分:承受短路的能力GB/T 1094.7 电力变压器第7部分:油浸式电力变压器负载导则GB/T 1094.10 电力变压器第10部分:声级测定GB 1208 电流互感器GB 1984 高压交流断路器GB 1985 高压交流隔离开关和接地开关GB 2536 电工流体变压器和开关用的未使用过的矿物绝缘油GB 2900.95 电工术语变压器、调压器和电抗器GB 3804 3.6kV~40.5kV高压交流负荷开关GB/T 4109 交流电压高于1000V的绝缘套管GB 4208 外壳防护等级(IP代码)GB/T 4585 交流系统用高压绝缘子的人工污秽试验GB 5273 变压器、高压电器和套管的接线端子GB/T 6451 油浸式电力变压器技术参数和要求GB/T 7252 变压器油中溶解气体分析和判断导则GB/T 7354 局部放电测量GB/T 7595 运行中变压器油质量GB 10230.1 分接开关第1部分性能要求和试验方法GB 10230.2 分接开关第2部分:应用导则GB 13499 电力变压器应用导则GB/T 13729 远动终端设备GB/T 14048.1 低压开关设备和控制设备第1部分:总则GB/T 14048.2 低压开关设备和控制设备第2部分:断路器GB 16926 交流高压负荷开关熔断器组合电器GB 16847 保护用电流互感器暂态特性技术要求GB 16927.1 高压试验技术第1部分:一般定义及试验要求GB 16927.2 高压试验技术第2部分:测量系统GB/T 16935.1 低压系统内设备的绝缘配合第1部分:原理、要求和试验2GB/T 17467 高压/低压预装式变电站GB/T 17468 电力变压器选用导则GB/T 26218.1 污秽条件下使用的高压绝缘子的选择和尺寸确定第1部分:定义、信息和一般原则GB/T 26218.2 污秽条件下使用的高压绝缘子的选择和尺寸确定第2部分:交流系统用瓷和玻璃绝缘子GB 50148 电气装置安装工程电力变压器、油浸电抗器、互感器施工及验收规范GB 50150 电气装置安装工程电气设备交接试验标准JB/T 10217 组合式变压器DL/T 537 高压/低压预装箱式变电站选用导则DL/T 572 电力变压器运行规程DL/T 593 高压开关设备和控制设备标准的共用技术要求DL/T 596 电力设备预防性试验规程DL/T 844 12kV少维护户外配电开关设备通用技术条件DL 911 电力变压器绕组变形的频率响应分析法DL 1093 电力变压器绕组变形的电抗法检测判断导则DL 1094 电力变压器用绝缘油选用指南DL 5027 电力设备典型消防规程3术语和定义下列术语和定义适用于本部分。
国标电气元件命名法
光敏
压敏
1
2
3
4
5
6
7
8
9
G
T
W
D
普通
普通
超高频
高阻
高温
-
精密
高压
特殊
高功率
可调
—
—
普通
普通
—
—
-
-
精密
特殊函数
特殊
—
-
微调
多圈
额定功率
阻值
允许误差
精度等级
R
热敏
B
C
P
W
Z
温度补偿
温度测量
旁热式
稳压式
正温度系数
1.2电阻器标称值阻值系列和允许偏差(GB2471—81)
E24
E12
E6
E24
E12
E6
允许偏差±5%
允许偏差±10%
允许偏差±20%
允许偏差±5%
允许偏差±10%
允许偏差±20%
1.0
1。0
1。0
3。3
3.3
3.3
1。1
3。6
1.2
1.2
3。9
3。9
1.3
4.3
1。5
1.5
1。5
4。7
4。7
4.7
1.6
5.1
1。8
1.8
5.6
5。6
2。0
6。2
2.2
2。2
2。2
6。8
6.8
6。8
N型,硅材料
P型,硅材料
P
V
W
C
Z
L
S
N
U
国家电网公司物资采购标准 (继电保护及自动化设备卷)35kV及以下变压器保护通用技术规范
500kV(330kV)线路光纤差动保护专用技术规范国家电网公司物资采购标准(继电保护及自动化设备卷变压器保护册)35kV及以下变压器保护通用技术规范(编号:1101003-0035-00)本规范对应的专用技术规范目录35kV及以下变压器保护采购标准技术规范使用说明1. 本标准技术规范分为通用部分和专用部分。
2. 采购标准技术规范通用部分原则上不需要设备招标人(项目单位)填写,更不允许随意更改。
如对其条款内容确实需要改动,项目单位应填写《项目单位通用部分条款变更表》并加盖该网、省公司招投标管理中心公章,与辅助说明文件随招标计划一起提交至招标文件审查会。
经标书审查同意后,对通用部分的修改形成《项目单位通用部分条款变更表》,放入专用部分,随招标文件同时发出并视为有效。
3. 采购标准技术规范专用部分分为标准技术参数、项目需求部分和投标人响应部分。
“标准技术参数表”中“标准参数值”栏是标准化参数,不允许项目单位和投标人改动。
项目单位对“标准参数值”栏的差异部分,应填写“项目单位技术差异表”,“投标人保证值”栏应由投标人认真逐项填写。
项目需求部分由项目单位填写,包括招标设备的工程概况和招标设备的使用条件。
对扩建工程,可以提出与原工程相适应的一次、二次及土建的接口要求。
投标人响应部分由投标人填写“投标人技术偏差表”,提供销售业绩、主要部件材料和其他要求提供的资料。
4. 投标人填写“技术参数和性能要求响应表”时,如与招标人要求有差异时,除填写“技术偏差表”外,必要时应提供相应试验报告。
5. 有关污秽、温度、海拔等需要修正的情况由项目单位提出并在专用部分的“项目单位技术差异表”中明确表示。
6. 采购标准技术规范的页面、标题等均为统一格式,不得随意更改。
7. 一次设备的型式、电气主接线和一次系统情况对二次设备的配置和功能要求影响较大,应在专用部分中详细说明。
目次35kV及以下变压器保护采购标准技术规范使用说明 (137)1 总则 (139)1.1 引言 (139)1.2 供方职责 (139)2 技术规范要求 (139)2.1 使用环境条件 (139)2.2 工作条件 (139)2.3 保护装置额定参数 (140)2.4 装置功率消耗 (140)2.5 35kV及以下变压器保护总的技术要求 (140)2.6 35kV及以下变压器保护装置的技术要求 (143)2.7 柜结构的技术要求 (144)3 试验 (144)3.1 工厂试验 (144)3.2 现场试验 (144)4 技术服务、设计联络、工厂检验和监造 (145)4.1 技术文件 (145)4.2 设计联络会议 (146)4.3 工厂验收和现场验收 (146)4.4 质量保证 (146)4.5 项目管理 (146)4.6 现场服务 (146)4.7 售后服务 (147)4.8 备品备件、专用工具、试验仪器 (147)1总则1.1引言提供设备的厂家、投标企业应具有ISO 9001质量保证体系认证证书,宜具有ISO 14001环境管理体系认证证书和OHSAS 18001职业健康安全管理体系认证证书及年检记录,宜具有AAA级资信等级证书、重合同守信用企业证书并具备良好的财务状况和商业信誉。
67项国网企标(2011)
标准号 Q/GDW166.1-2010
选题名称
估价
国家电网公司输变电工程初步设计内容深度规定 第1部分: 110(66)KV架空输电线路 国家电网公司输变电工程初步设计内容深度规定 第2部分: Q/GDW166.2-2010 110(66)KV变电站
Q/GDW166.3-2010 Q/GDW166.4-2010 Q/GDW166.6-2010 Q/GDW166.7-2010 Q/GDW166.8-2010 Q/GDW166.9-2010 Q/GDW 381.1-2010 国家电网公司输变电工程初步设计内容深度规定 第3部分:电力 电缆线路 国家电网公司输变电工程初步设计内容深度规定 第4部分:电力 系统光纤通信 国家电网公司输变电工程初步设计内容深度规定 第6部分:220KV 架空输电线路 国家电网公司输变电工程初步设计内容深度规定 第7部分: 330KV-750KV交直流架空输电线路 国家电网公司输变电工程初步设计内容深度规定 第8部分:220KV 变电站 国家电网公司输变电工程初步设计内容深度规定 第9部分: 330KV-750KV变电站 国家电网公司输变电工程施工图设计内容深度规定 第1部分:110 (66)kV变电站 国家电网公司输变电工程施工图设计内容深度规定 第4部分:110 (66)kV架空输电线路 国家电网公司输变电工程施工图设计内容深度规定 第5部分: 220kV变电站 国家电网公司输变电工程施工图设计内容深度规定 第6部分: 330kV~750kV变电站 国家电网公司输变电工程施工图设计内容深度规定 第7部分: 220kV架空输电线路 国家电网公司输变电工程施工图设计内容深度规定 第8部分: 330kV~750kV交直流架空输电线路 输电线路气象监测装置技术规范 输电线路导线温度监测装置技术规范 输电线路微风振动监测装置技术规范 高压直流输电换流阀状态检修导则 高压直流输电换流阀状态评价导则 高压直流输电直流测量装置状态检修导则 高压直流输电直流测量装置状态评价导则 高压直流输电干式平波电抗器状态检修导则 高压直流输电干式平波电抗器状态评价导则 高压直流输电高速直流开关状态检修导则 高压直流输电高速直流开关状态评价导则 高压直流输电交直流滤波器及并联电容器装置状态检修导则 高压直流输电交直流滤波器及并联电容器装置状态评价导则 高压直流输电换流阀冷却系统状态检修导则 高压直流输电换流阀冷却系统状态评价导则 高压直流输电控制保护系统状态检修导则 11.00 11.00
企标示例
上海市企业标准Q/**** 01-2014代替Q/**** 01-2011高压交流负荷开关熔断器组合电器(英文名称)2014—04—26发布 2014—04—27实施×××电力设备有限公司发布目次前言 (II)1 范围 (1)2 规范性引用文件 (1)3术语和定义 (1)4 基本参数 (1)5 要求 (2)6 试验方法 (3)7 检验规则 (3)8 标志、包装、运输、贮存 (4)附录A(规范性附录)在内部故障电弧条件下金属封闭开关设备和控制设备试验的方法 (5)前言本标准技术指标主要依据GB/T 11022—1999 《高压开关设备和控制设备标准的共用技术要求》制定。
本标准技术指标中的“××××”指标依据GB/T 11022—1999 《高压开关设备和控制设备标准的共用技术要求》制定;“××××”指标依据GB/T 2900.20—1994 《电工术语高压开关设备》制定。
本标准技术要求和具体指标是依据产品特性,在产品实测值基础上制定的。
本标准修改采用IEC62271-105:2002《高压开关设备和控制设备第105部分:交流负荷开关-熔断器组合电器》。
本标准与IEC62271-105:202的主要差异在:——适用范围。
适用的系统的最低电压由IEC62271-105的1000V改为3000V;——按照GB3804对负荷开关进行试验,且这些试验可以在另一个不同于按照本标准对组合电器进行试验的组合电器上进行;——按照GV15166.2对熔断器进行试验;——按照本标准对组合电器进行试验;——删除了熔断器-负荷开关组合电器的相关条款。
本标准的编写格式根据GB/T 1.1-2009《标准化工作导则第一部分:标准的结构和编写规则》制定。
本标准的附录A是资料性附录。
本标准由××××电力设备有限公司提出并起草。
国家电网公司企业标准
个人总结,仅供交流学习,精品资料国家电网公司企业标准电力负荷管理系统通用技术条件--发布--实施中华人民共和国国家电网公司发布目次前言范围错误!未指定书签。
规范性引用文件错误!未指定书签。
定义错误!未指定书签。
技术要求错误!未指定书签。
系统主要性能指标…………………………………………………………………………………………主站要求……………………………………………………………………………………………………终端技术要求………………………………………………………………………………………………终端试验方法错误!未指定书签。
一般规定……………………………………………………………………………………………………结构和机械试验气候影响试验……绝缘性能试验………………………………………………………………………………………………电源影响试验………………………………………………………………………………………………传输信道试验………………………………………………………………………………………………功能和性能试验……………………………………………………………………………………………电磁兼容性试验……………………………………………………………………………………………连续通电的稳定性试验……………………………………………………………………………………可靠性验证试验…………………………………………………………………………………………检验规则错误!未指定书签。
检验规则…………………………………………………………………………………………..…………检验分类……………………………………………………………………………………………………出厂检验……………………………………………………………………………………………………型式检验…………项目和顺序…………………………………………………………………………………………………标志、运输、贮存错误!未指定书签。
国网企标培训-首版、修改版与DL的对比及加强报告内容-薛春林董建尧
杆塔荷载
国网企标修改版A主要修改如下:
•1 取消原表18(导线、地线断线时覆冰率)、表19(覆冰不平衡张力覆冰率), 请根据工程实际进行判断。 •2 断线张力或分裂导线的不平衡张力取值适当减小。 10mm及以下冰区导线、地线断线张力或不平衡张力取值对照表
杆塔荷载
国网企标修改版A主要修改如下:
10mm及以下冰区导线、地线断线张力或不平衡张力取值对照表
注:红字为修改版A新增加内容。
气象条件
1、基本风速、基本冰厚重现期及基准高的确定
DL/T 50921999 GDW 102-2003 风、冰重现期 750kV线路 500kV大跨越 500kV线路 110kV~330kV大跨 越 110kV~330kV线路 风50其它30 50 30 30 15 风、冰重现期 50 50 50 30 30 Q/GDW 1792008 DL/T 5092-1999 GDW 1022003 基准高 20 10 20 10 15 Q/GDW 1792008 DL/T 50921999 GDW 1022003 基本风速 30 不低于30 30 不低于25 25 Q/GDW 1792008
10
20
30
40
12.1.9 各类杆塔不均匀覆冰的不平衡张力应计算下列荷载组合: 1 每相导线和每根地线同时同向有不均匀覆冰荷载,组合使杆塔产生最大的弯矩; 2 每相导线和每根地线同时不同向有不均匀覆冰荷载,组合使杆塔产生最大扭矩; 3 部分相导线和一根地线同时有不均匀冰荷载,组合使杆塔承受弯扭的最不利组合。
绝缘子和金具
国网企标主要新增和修改:
8.1 绝缘子机械强度的安全系数,不应小于表8所列数值。 双联及以上的多联绝缘子串应验算断一联后的机械强度, 其荷载及安全系数按断联情况考虑。 8.1绝缘子机械强度安全系数 最大使用荷载 情 况 盘型绝缘子 2.7 棒型绝缘子 3.0 安全系数 验算 1.8 断 线 1.8 断 联 1.5
干货国网工程量清单计价规范企标(2016)
第一部分 工程量清单计价简述
五、工程各阶段造价控制简介(四算、四价)
估算 概算 预算 最高投 投标价 签约
竣工 决算
标限价
合同价 结算价
10
第一部分 工程量清单计价简述 第二部分 “计价规范”重点条文解读 第三部分 变电工程及线路工程工程量计 算规范简要讲解 第四部分 线路工程新施工工艺简介
11
14
2 术语和定义
条目
规范原条文
2
术 2.9 风险费用
语
操作与应用解读 风险:风险是指某一特定危险情况发生的可能性和后果的 组合。
风险费用:用于化解发承包双方在合同中约定内容和范围 内的市场价格波动风险的费用
由发包人承担:法规、政策性变化的风险
(1)国家法律、法规、规章和政策发生变化。 (2)行业建设主管部门发布的人工费调整,但承包人对人工费或人工单价的报价高于发 布的除外。 由承包人承担:技术、管理风险:
载明建设工程的分部分项工程项目、措施项 目和其他项目的名称和相应数量以及规费和税金 项目等内容的明细清单。
“招标工程量清单”、“已标价工程量清单”是 在工程发承包的不同阶段,对工程量清单的进一 步具体化。 从“工程量清单”的作用方面再进行细化,“招 标工程量清单”强调随招标文件发布的供投标报 价所用;“已标价工程量清单”更加强调该清单 为承包人所确定的投标后的清单文件。
由于承包人使用机械设备、施工技术以及组织管理水平等自身原因造成施工费用增加的 ,应由承包人全部承担。如管理费和利润。 双方分担:市场物价波动风险。 应由发、承包双方合理分摊。如材料、机械等价格风险。材料价格的风险宜控制在5%以 内,施工机械使用费的风险可控制在 10%以内,超过者予以调整。 各自承担:不可抗力风险:
国网公司58个专业名词解释
国网公司58个专业名词解释1、六统一、新六统一、九统一:六统一为国网公司对保护装置的功能配置、回路设计、端子排布置、接口标准、屏柜压板、保护定值(报告格式)六个方面做出的统一规范。
后面发布新六统一对智能站入网测试、保护功能、信息规范进行统一,九统一确定版本认证测试、信息展示、信息规范。
2、主保护:满足系统稳定和设备安全要求,能以最快速度有选择地切除被保护设备和线路故障的保护。
3、高频闭锁距离保护:利用距离保护的启动元件和距离方向元件控制收发信机发出高频闭锁信号,闭锁两侧保护的原理构成的高频保护。
4、二次设备:是指对一次设备的工作进行监测、控制、调节、保护以及为运行、维护人员提供运行工况或生产指挥信号所需的低压电气设备。
5、重复接地:将零线上的一点或多点,与大地进行再一次的连接叫重复接地。
6、距离保护:是利用阻抗元件来反应短路故障的保护装置。
因阻抗元件反应接入该元件的电压与电流的比值(U/I=Z),即反应短路故障点至保护安装处的阻抗值,而线路的阻抗与距离成正比,所以称这种保护为距离保护或阻抗保护。
7、零序保护:在大短路电流接地系统中发生接地故障后,就有零序电流、零序电压和零序功率出现,利用这些电量构成保护接地短路的继电保护装置统称为零序保护。
零序电流保护就是常用的一种。
8、后备保护:是指当某一元件的主保护或断路器拒绝动作时,能够以较长时限(相对于主保护)切除故障元件的保护元件。
9、高频保护:就是故障后将线路两端的电流相位或功率方向转化为高频信号,然后利用输电线路本身构成一高频电流通道,将此信号送至对端,以比较两端电流相位或功率方向的一种保护。
10、电力系统安全自动装置:是指防止电力系统失去稳定和避免电力系统发生大面积停电的自动保护装置。
11、电力系统事故:是指电力系统设备故障或人员工作失误,影响电能供应数量和质量并超过规定范围的事件。
12、谐振过电压:电力系统中一些电感、电容元件在系统进行操作或发生故障时可形成各种振荡回路,在一定的能源下,会产生串联谐振现象,导致系统某些元件出现严重的过电压。
国家电网公司企业标准
IICS F国 家 电 网 公 司 企 业 标 准Q /GDW ×××—2008±800kV 架空输电线路张力架线施工工艺导则Construction technology guide for tension stringingof ±800kV overhead transmission line(报批稿)Q/GDW ×××-20062008-××-××发布2008-××-××实施中华人民共和国国家电网公司发布IIQ/GDW ×××-2008目次前言......................................................................................................................... I I1 范围 (1)2 规范性引用文件 (1)3 一般规定 (1)4 施工准备 (3)5 张力放线 (15)6 紧线 (30)7 附件安装 (36)8 施工质量及安全措施 (40)IQ/GDW ×××-2006II 前言《±800kV架空输电线路张力架线施工工艺导则》是由国网直流工程建设有限公司负责组织有关单位编制的国家电网公司企业技术标准。
本标准是参照SDJJS 2-1987 《超高压架空输电线路张力架线施工工艺导则》(试行)及DL/T5343—2006《750kV架空送电线路张力架线施工工艺导则》,结合我国架空输电线路施工技术和施工经验编写的。
本标准包括如下内容:——张力架线施工机具及跨越施工准备;——张力放线施工区段及牵引场、张力场布置;——导引绳、牵引绳及地线的展放;——张力放线主要施工计算;——张力放线施工操作;——紧线工艺、弧垂观测与调整;——附件安装;——施工质量及安全措施。
国家电网企标QGDW11008与国标GBT7251.3的差异分析
质量监管2020年12月(上)/ 总第274期671 适用范围差异国标GB/T7251.3-2017适用于由一般人员操作的配电板(DBO)的具体要求,而国网企标Q/GDW 11008-2013主要用于公司系统计量箱的招标、订货、检验、验收和安装使用。
为适应全国网系统的实际使用情况,从箱体材质、表位数、表位排列、进出线方式、开关导线配置等方面考虑,覆盖了多种计量箱规格。
2 试验的差异2.1试验项目的差异国标GB/T7251.3-2017共13项试验项目,具体如下:(1)一般检查;(2)外壳热稳定;(3)绝缘材料耐受内部电效应引起的非正常发热和着火的验证;(4)耐紫外线(UV)辐射验证;(5)机械撞击试验;(6)成套设备的防护等级;(7)机械操作;(8)标志;(9)耐腐蚀性;(10)电气间隙和爬电距离;(11)介电性能;(12)温升验证;(13)提升试验。
国网企标与国标相比新增试验项目10项,删除试验项目1项。
由于计量箱体积小,重量轻,可以人工搬运,故删除提升试验。
2.2 新增试验项目(1)耐热性试验:该试验适应于计量箱内的绝缘部件、非金属计量箱外壳。
绝缘部件经过70℃高温存储后,进行球压试验进行判定。
国标2006版老标准里有此项试验,但是适用于固定载流部件的绝缘材料,温度为125℃,2017新换版国准已删除此项试验。
(2)温度冲击试验:该试验适应于非金属计量箱,测试非金属计量箱对于温度的适应性。
(3)塑料冲击性能测定试验:该试验适应于计量箱外壳塑料部分(非金属计量箱外壳、计量箱观察窗、金属计量箱外壳塑料部分),以测试相应材料的脆性和韧性,不同材质的判定标准不同:PC+ABS:≥42,SMC: ≥55,PC: ≥45。
(4)塑料弯曲性能测定试验:该试验适应于计量箱外壳塑料部分(非金属计量箱外壳、计量箱观察窗、金属计量箱外壳塑料部分),以测试相应材料的弯曲性能,不同材质的判定标准不同:PC+ABS:≥65,SMC: ≥140,PC: ≥95。
配电系统常用电气元件及符
一次系统元件:隔离刀开关 图片
电气符号
功能:用于隔离电源,使其间有一明显可看见的断开 点。
低压(690V、400V)
一次系统元件:电力电容器 图片
电气符号
功能:补偿电力系统感性负荷的无功功率,以提高功 率因数,改善电压质量,降低线路损耗。
低压(690V、400V)
一次系统元件:交流接触器 图片
电气符号
用户侧(400V、220V)
一次系统元件:电流互感器 图片
电气符号
功能:把数值较大的一次电流通过一定的变比转换为 数值较小的二次电流,用来进行电流测量。
用户侧(400V、220V)
一次系统元件:剩余电流互感器 图片
电气符号
功能:用于剩余电流的采集,可与电气火灾监控装置、 电动机保护装置以及剩余电流继电器配套使用。
中压(35kV、10kV、6kV)
一次系统元件:电压互感器 图片
电气符号
功能:把高电压按比例关系变换成100V或更低等级的 标准二次电压,供保护、计量、仪表装置使用。
中压(35kV、10kV、6kV)
一次系统元件:电流互感器 图片
电气符号
测量绕组 计量绕组 保护绕组
功能:把数值较大的一次电流通过一定的变比转换为数值较 小的二次电流(5A、1A),用来进行保护、测量、计量等用途。
电气符号
功能:控制电气回路分合的开关。
用户侧(400V、220V)
一次系统元件:双电源切换装置 图片
电气符号
功能:用在紧急供电系统,将负载电路从一个电源自 动换接至另一个(备用)电源的开关电器,以确保重 要负荷连续、可靠运行。
用户侧(400V、220V)
一次系统元件:刀开关 图片
电气符号
设备管理技术标准能力提升(18项反措新)题库(开关类和四小器及辅助类)及答案
设备管理技术标准能力提升练习(开关类和四小器及辅助类)答案一、单选题第1 题, 本小题1 分12kV(7.2)~40.5kV开关柜用镀铝锌钢板的术语和定义、分类和代号、尺寸、外形、(____)、技术要求、检验和试验、包装、标志和质量证明书参照本标准执行A. 运输B. 重量C. 型式试验D. 大小标准答案:B本题得分:0 分第2 题, 本小题1 分“110(66)kV及以上电磁式电压互感器绕组tanδ应满足:串级式:介损因数≤(____);非串级式:介损因数≤0.005。
” A.0.015B. 0.02C. 0.025D. 0.05标准答案:B本题得分:0 分第3 题, 本小题1 分全膜介质的电容器在工频交流额定电压下,20℃时损耗角正切值不应大于(____)。
A.0.05%B. 0.08C. 0.03%D. 0.01%标准答案:C本题得分:0 分第4 题, 本小题1 分因组合电器技术标准执行指导意见对GB/T 11022-2011相关内容进行了引用,但本执行指导意见已将DL/T593-2016列为主标准,故建议本标准中凡注明引用GB/T 11022-2011的条款在执行时应引用DL/T593-2016的对应条款。
以上执行条款的制定遵循了哪项原则? A. 主次原则B. 通用原则C. 从严就高原则D. 从严就全原则标准答案:B本题得分:0 分第5 题, 本小题1 分国网企标11651.5-2017《变电站设备验收规范第5部分:开关柜》适用于(____)及以上变电站站内空气绝缘开关柜和充气绝缘开关柜的验收工作。
A. 10kVB. 35kVC. 110kVD. 220kV标准答案:B本题得分:0 分第6 题, 本小题1 分下列(____)项试验不是电磁式电压互感器例行试验项目? A. 绕组绝缘电阻B. 绕组绝缘介质损耗因数(20℃)C. 红外热像检测D. 局部放电测量标准答案:D本题得分:0 分第7 题, 本小题1 分下列(____)阶段不属于全过程技术监督阶段? A. 规划可研B. 工程设计C. 采购制造D. 带电检测标准答案:D本题得分:0 分第8 题, 本小题1 分220kV-500kV串联电容器补偿装置主标准应执行以下哪个标准? A. GB/T 6115.1《电力系统用串联电容器第1部分:总则》B. DL/T 1219-2013《串联电容器补偿装置设计导则》C. Q/GDW 10655《串联电容器补偿装置通用技术要求》D. DL/T 1274-2013《1000kV串联电容器补偿装置技术规范》标准答案:B本题得分:0 分第9 题, 本小题1 分220kV及以上串补装置MOV每相热备用容量为多少? A. 1个单元B. 2个单元C. 3个单元D. 4个单元标准答案:C本题得分:0 分第10 题, 本小题1 分避雷器(____)是避雷器的技术规范、技术条件类标准,包括设备额定参数值、设计与结构、型式试验/出厂试验项目及要求等内容。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
1) 参数(系统参数、装置参数); 2) 保护装置数值型定值部分; 3) 保护装置控制字定值部分; 4) 保护装置软压板部分。 4.1.6 保护装置应具备以下接口: a) 对时接口:使用 RS-485 串行数据通信接口接受 GPS 发出的 IRIG-B(DC)时码; b) 通信接口:3 组通信接口(包括以太网或 RS-485 通信接口),调试接口、打印机接口。 4.1.7 装置在正常运行时应能显示差流、电流、电压等必要的参数及运行信息,默认状态下,相 关的数值显示为二次值。装置也可选择显示系统的一次值。 4.1.8 保护装置应能记录相关保护动作信息,保留 8 次以上最新动作报告。每个动作报告应包含 故障前 2 个周波、故障后 6 个周波的数据。 4.1.9 保护装置记录的所有数据应能转换为IEC 60255-24 的电力系统暂态数据交换通用格式 (Common Format for Transient Data Exchange,简称COMTRADE)。 4.1.10 保护装置记录的动作报告应分类显示: a) 供运行、检修人员直接在装置液晶屏调阅和打印的功能,便于值班人员尽快了解情况和 事故处理的保护动作信息; b) 供继电保护专业人员分析事故和保护动作行为的记录。 4.2 保护配置及二次回路的通用要求 4.2.1 对保护配置及组屏(柜)的要求 a) 应遵循“强化主保护,简化后备保护和二次回路”的原则进行保护配置、选型与整定; b) 优先采用主、后备保护一体化的微机型继电保护装置,保护应能反映被保护设备的各种 故障及异常状态; c) 双重化配置的继电保护装置应分别组在各自的保护屏(柜)内,保护装置退出、消缺或
器额定容量、电流互感器(CT)和电压互感器(PT)的变比等必要的参数; c) 保护总体功能投/退,如“高压侧后备保护”,可由运行人员就地投/退硬压板或远方操作
投/退软压板实现; d) 运行中基本不变的、保护分项功能,如“高压侧复合电压闭锁过流Ⅰ段”采用“控制
字”投/退; e) 保护装置的定值清单应按以下顺序排列:
II
Q/GDW 175―2008
变压器、高压并联电抗器和母线保护及辅助装置标准化设计规范
1 范围
本标准规定了 220 kV 及以上电网的变压器、高压并联电抗器、母线和母联(分段)保护及辅 助装置的技术原则和设计准则。
本标准适用于国家电网公司 220 kV 及以上电压等级变压器、高压并联电抗器、母线和母联 (分段)及相关设备继电保护装置和回路的设计工作。110 kV 及以下电压等级相应保护设计工作 可参照执行。
ICS 29.240.30
Q/GDW
国家电网公司企业标准
Q/GDW 175—2008
变压器、高压并联电抗器和母线保护及 辅助装置标准化设计规范
Standardization design specification for power transformer,high voltage shunt reactor,bus bar protection and auxiliary equipments
2007-XX-XX 发布
国家电网公司 发 布
2007-XX-XX 实施
Q/GDW 175―2008
目次
前 言 ..................................................................................................................................... II 1 范围 ....................................................................................................................................... 1 2 规范性引用文件...................................................................................................................... 1 3 总则 ....................................................................................................................................... 1 4 一般规定 ................................................................................................................................ 2 5 变压器保护及辅助装置设计规范............................................................................................. 4 6 高抗保护设计规范 ................................................................................................................ 15 7 母线保护设计规范 ................................................................................................................ 20 8 母联(分段)充电过流保护及辅助装置设计规范.................................................................. 25 9 对相关设备及回路的要求 ..................................................................................................... 26 附录 A (规范性附录) 变压器保护装置定值清单标准格式 .................................................... 28 附录 B (规范性附录) 高抗保护装置定值清单标准格式 ........................................................ 44 附录 C (规范性附录) 母线保护装置定值清单标准格式 ........................................................ 46 附录 D (规范性附录) 母联(分段)保护装置定值清单标准格式.......................................... 50 附录 E (规范性附录) 保护输出报告标准格式 ...................................................................... 52 附录 F (资料性附录) 变压器保护跳闸矩阵表....................................................................... 53
3 总则
3.1 本标准旨在通过规范 220 kV及以上系统的变压器、高压并联电抗器、母线和母联(分段)保 护及辅助装置的技术原则、配置原则、组屏(柜)方案、端子排设计、压板设置和回路设计,提 高继电保护设备的标准化水平,为继电保护的制造、设计、运行、管理和维护工作提供有利条 件,提升继电保护运行、管理水平。 3.2 应优先通过继电保护装置自身实现相关保护功能,尽可能减少外部输入量,以降低对相关回 路和设备的依赖。 3.3 应优化回路设计,在确保可靠实现继电保护功能的前提下,尽可能减少屏(柜)内装置间以 及屏(柜)间的连线。 3.4 继电保护双重化包括保护装置的双重化以及与保护配合回路(包括通道)的双重化,双重化 配置的保护装置及其回路之间应完全独立,不应有直接的电气联系。 3.5 本标准中 330 kV及以上电压等级变压器以高压侧 3/2 断路器接线、中压侧双母双分段接线、 低压侧单母接线,变压器低压侧有总断路器的分相自耦变压器为例。220 kV电压等级变压器以高 中压侧双母线接线、低压侧双分支单母分段接线的三卷变压器为例。其他情况可参照执行。 3.6 本标准中高压并联电抗器(简称高抗)以 3/2 断路器接线的线路电抗器为例。其他情况可参 照执行。 3.7 本标准中母线以 3/2 断路器接线和双母双分段接线为例。其他情况可参照执行。 3.8 本标准中母联(分段)以双母线接线的母联断路器为例。其他情况可参照执行。 3.9 本标准强调了变压器、高抗、母线和母联(分段)保护及辅助装置标准化设计的原则和重点 要求,但并未涵盖相应保护及辅助装置的全部技术要求,有些内容在已颁发的技术标准和规程、 规定中已有明确规定,在贯彻落实的过程中仍应严格执行相关的技术标准和规程、规定。
1
Q/GDW 175―2007
3.10 新建、扩建和技改等工程应执行本标准。
4 一般规定