宝石能谱CT低电压联合自适应性统计迭代重建在腹部扫描中的应用
宝石能谱CT冠脉低剂量扫描技术的临床应用价值
宝石能谱CT冠脉低剂量扫描技术的临床应用价值摘要】目的探讨宝石能谱CT在冠脉低剂量扫描技术的应用价值.方法对比分析宝石能谱CT 前瞻性门控与回顾性门控扫描模式冠状动脉CT 成像的X线剂量差异,评价宝石CT前瞻性门控的应用价值.结果在相同管电压条件下,前瞻性门控模式冠脉成像检查的CT剂量指数(CTDI)、剂量长度乘积(DLP)和有效剂量(ED)三种参数分别较回顾性门控组降低53.26%,26.87%和53.26%,差异有统计学意义(P <0.001).前瞻性门控模式冠脉成像检查的图像质量,升主动脉、降主动脉、左心房的CT值和噪声(SD)值两组差异无统计学意义.结论:宝石能谱CT前瞻性心电门控模式冠脉成像能满足临床诊断需要,同时也非常的降低了辐射剂量. 【关键词】宝石能谱CT;心电门控;低剂量技术;冠状动脉成像【中图分类号】R816.2【文献标识码】B【文章编号】1008-6315(2015)10-0365-01随着多层螺旋CT冠状动脉成像技术的飞速发展,CT 冠状动脉造影以其无创、简便、安全、准确、迅速、并发症少等优点,在临床得到愈来愈多的应用和信赖.同时CT检查带来的辐射剂量管理问题成为临床及社会关注的热点.笔者通过研究宝石能谱CT冠脉低剂量扫描技术在在冠心病患者中的可行性,探讨实行有效的低剂量管理的可行性方法.1材料与方法1.1一般资料连续搜集2015年1月至2015年5月在我院接受64排螺旋CT 冠状动脉成像者185例,其中男101例,女84例,年龄31-83岁,平均56.78岁.病例纳入标准:心率范围50-90次/min,身体无急性心功能不全,无严重心律失常及严重肾功能损害.1.2检查方法1.2.1设备与材料使用GEDiscoveryCT750 HD 宝石CT 机.NEMOTOCT 用高压双筒注射器,对比剂使用碘海醇350mgI/ml,采用ivyBIOMEDICAL公司3150型心电监护仪.1.2.2扫描前准备无碘过敏及药物禁忌症下,舌下含服酒石酸美托洛尔片25-75mg,待心率降低及稳定到70次/分以下,建立静脉通路.训练患者屏气及告知扫描相关注意事项,完成扫描前准备工作.1.2.3扫描参数选择探测器宽度40mm,扫描层厚0.625mm,球管旋转时间0.35s,管电压120KV,ASIRslice30%重建模式.前瞻性门控扫描模式采用轴位扫描,根据患者体重指数(BMI)选择管电流200-600mA.回顾性门控扫描模式采用螺旋扫描,选择自动毫安管电流控制技术.1.2.4扫描方法患者采用脚先进仰卧位,正确连接ECG 电极.扫描范围自气管隆突下1cm 至心脏底部膈肌平面,通过钙化积分扫描确定升主动脉根部左冠主干开口层面,以此作为小剂量测试层面.经肘前静脉以4.0ml/s流速注射对比剂20ml,生理盐水20ml.延迟8s后在监测层面间隔1s进行多次重复扫描,根据升主动脉根部感兴趣区时间-密度曲线,计算主动脉达峰时间进行最后的冠脉扫描.流速4.0ml/s,对比剂65-75ml,盐水40-50ml.1.3图像后处理及分析1.3.1图像后处理将扫描完成后的图像传到ADW4.5工作站进行后处理重建,利用软件功能进行多平面重组(MPR)、容积再现(VR)、最大密度投影(MIP)重建出冠状动脉图像,选出质量最佳者用于影像诊断学评价.1.3.2图像分析将受检者随机分成常规组(回顾性门控扫描)A 组和前瞻性门控扫描组B组,A 组98例,B组83例.图像质量评分:由2名影像诊断医师以双盲法对A 和B组图像从冠状动脉节段的显示数目、3级以上分支显示率、血管边缘锐利度、管腔内对比剂清晰度4个方面以1-4分(4分为优)进行图像质量评分.4分:冠状动脉显示13节段以上,3级以上分支可显示,血管边缘光滑锐利,管腔内对比剂显示清晰;3分:4项中1项不符;2分:4项中2项不符;1分:4项中3项不符.记录各组分值,评分有分歧的由2人共同协商后达成一致.测定图像噪声值选取两组图像中面积相等的感兴趣区,面积为100mm2,在左冠状动脉主干支层面测量升主动脉中心部的CT 值,得出两组图像噪声值,计算其均值及标准差.1.4射线剂量评估定量指标包括:CT剂量指数(CTdoseindex,CTDI);计量长度乘积(doselengthproduct,DLP);有效剂量(effectivedose,ED)=DLP×0.014,0.014为胸部特定转换系数k[1].1.5统计学处理应用SPSS19.0软件对上述各组数据进行统计学分析,对A,B 两组图像的CTDI、DLP,ED以及质量评分、CT 值、SD 值的组间差异分别行t检验,P <0.05为有统计学意义.2结果2.1不同冠脉CTA 扫描模式对辐射剂量和图像质量的影响前瞻性门控模式冠脉成像检查的CTDI、DLP、ED三种参数的统计结果均低于回顾性门控冠脉成像检查,且差异有统计学意义(P <0.001).两种不同扫描方案获得的心脏重组图像肉眼观察无差异,两组间的图像质量评分无显著差异(P>0.05).见表1.3讨论随着冠脉CTA 检查技术的日臻完善,冠脉CTA 已经成为冠心病的主要检查手段,但与此同时,人们也越来越关注冠脉CTA 的辐射剂量.如何在保证检查成功的基础上有效的减少射线剂量,已经成为冠脉CTA 面临的重要问题.工作中针对患者个体特点及诊断需要,应用前瞻性低剂量扫描技术在保证图像质量满足诊断的前提下,最大限度地降低患者所受辐射的剂量[2].冠脉CTA 的低剂量扫描模式是指根据病人的具体情况,合理降低电压、个性化降低管电流以及采用低剂量的图像采集模式等[3-5].前瞻性心电门控序列扫描模式是指通过实时监测心电信号,预判下一个心动周期R 波出现的时间,并只在预设的心动期相进行X 线曝光扫描,其他心动期相X 线完全关闭;扫描时检查床不动,上一个扫描的X 线曝光结束,扫描床迅速进入下一个位置,等待心电信号控制的正确心动期相开始触发下一个扫描.相对比而言,回顾性心电门控螺旋扫描技术对心脏的每一个位置都重复照射了3到5圈,而前瞻性心电触发扫描的图像很少重叠,从而在很大程度上减少了辐射剂量.前瞻性心电门控序列扫描可使剂量减少60%~80%[6].本研究对比分析宝石能谱CT 前瞻性门控与回顾性门控扫描模式冠状动脉CT成像的X线剂量和图像质量的差异,结果表明,在相同管电压条件下,前瞻性门控模式冠脉成像检查的CTDI、DLP、ED三种参数的统计结果均显著低于回顾性门控冠脉成像检查,其降低幅度与贾爱英,潘自兵,郭道德等[7-9]基本一致.两种不同扫描方案获得的心脏重组图像肉眼观察无差异,两组间的图像质量评分无显著差异.说明宝石能谱CT前瞻性心电门控技术在冠脉CTA 成像检查中,确实是一种在确保图像质量能够满足诊断要求的同时,减低射线剂量行之有效的方法之一.因此,利用宝石能谱CT 机型的先进技术,根据诊断需求确定适当的影像质量标准及相应的扫描方案,且根据受检者情况选择最佳扫描模式进行合理的参数优化是需要我们放射科医师和技师来共同努力完成的.要想达到降低冠脉CTA 检查的辐射剂量的目的,不仅需要医院购买先进CT 机器,更需要加强对CT 工作人员的培训,敦促CT 工作人员加强对CT 辐射概念的理解和对所使用CT 设备性能的了解掌握,使CT 工作人员在冠脉CTA 检查实施中,进行个性化优化扫描参数,尽可能选择低剂量扫描模式,缩小扫描范围,使用最新的重建算法,争取做到在低剂量水平获取满足诊断需求的影像信息.同时应用低剂量扫描与经济效益低剂量扫描可以大大延长球管的寿命,降低球管维护和保养的费用,提高机器利用率创造更好的经济效益,值得临床进一步推广应用.参考文献[1]沈俊林,郭道德,杜祥颖,等.低电压技术在基于噪声的低电流扫描冠状动脉CTA 中的应用[J].中国医学影像技术,2013,29(11):1891-1895.[2]黄科峰.低剂量扫描技术对冠状动脉成像的研究[J].临床军医杂志,2011,39(5):30-34.[3]HalliburtonSS,AbbaraS,ChenMY,eta1SCCTguidelinesonradiGationdoteanddose-optimizationstrategiesincardiovascularCT[J].JCardiovascComputTomogr,2011,5(4):198-224.[4]Klass0,WalkerM,SiebachA,eta 1.ProspectivelvgatedaxialCTcoronary angiography:com parison ofimage quality and effectiveradiationdosebetween64-and256-sliceCT[J].EurRadio,2010,20(5):1121-1131.[5]GaoJ,LiJ,EarlsJ,etal.Individualizedtubecurrentselectionfor64-rowcardiacCTAbasedonanalysisofthescoutview [J].EurJRadiol,2011,79(2):266-271.[6]曹丽珍,杜祥颖,李鹏雨,等.前瞻性心电触发轴位扫描技术在64层螺旋CT中的应用[J].中华老年心脑血管病杂志,2010,12(6):512-514.[7]贾爱英宝石CT低剂量扫描在冠脉成像中的应用[J]医学影像学杂志,2014,24(7):1251-1252.[8]潘自兵,赵凯,张志远.基于宝石CT前瞻性与回顾性扫描在冠状动脉成像中的剂量对比[J].宁夏医学杂志2013,35(8):698-699.[9]郭道德,李岩,白桦,等.冠脉CTA 检查方式对辐射剂量影响的多中心研究[J].中国医疗设备,2014,29(1):16-18。
自适应统计迭代技术降低腹部CT放射剂量的研究分析
自适应统计迭代技术降低腹部CT放射剂量的研究分析目的对自适应统计迭代技术(ASiR)降低腹部CT放射剂量的作用进行评价分析。
方法抽取在2013年1月~2014年12月我院接受腹部CT检查的临床患者48例,将其按照检查方法分成滤波反投影(FBP组)和ASiR50%组,ASiR50%组患者接受设备内置剂量降低技术(DR),两组患者均接受ATCM,FBP组重建获取FBP图像,ASiR50%组重建获得FBP与ASiR50%两组图像,对肝实质、脾实质、胰腺实质、皮下脂肪、主动脉噪声(SD)和CT,以SD值的平均值作为图像的噪声,对两组容积CT剂量指数进行记录,并对比分析。
结果ASiR50%组图像噪声较FBP图像发生明显降低(P<0.05);ASiR50%组组平均容积CT剂量较FBP发生显著降低(P<0.05)。
结论ASiR重建技术能够使图像噪声降低,并提高图像质量,与FBP重建技术对比发现,适当的噪声指数与ASiR50%能够使放射剂量有效降低,并获得质量相同或相似的图像,在今后的临床工作中应对其给予足够的重视。
标签:自适应统计迭代技术;腹部CT;放射剂量;临床价值近几年随着螺旋CT技术的不断发展和日渐成熟,特别是多层螺旋CT的问世,使得临床疾病诊断水平得到很大程度的提高,但是需要注意的是,影像学技术在获得准确的诊断图像的同时,扫描也会产生一定程度的辐射,进而对患者产生一定程度的影响[1]。
因此在提高影像学诊断质量的同时,减少辐射为目前临床诊断工作中所面临的一个重要难题[2]。
本次研究中出于对自适应统计迭代技术(ASiR)降低腹部CT放射剂量的作用进行评价分析的目的,对我院收治的接受腹部CT检查的临床患者的临床资料展开了回顾性分析。
1资料与方法1.1一般资料研究中资料来源于我院收治的接受腹部CT检查的临床患者,抽取其中的48例作为研究对象,将其按照扫描方法共分成FBP组和ASiR50%组,每组24例,FBP组中包括有男13例,女11例,年龄23~65岁,平均(44.7±13.5)岁;ASiR50%组中包括有男14例,女10例,年龄25~70岁,平均(46.1±14.2)岁。
CT能谱成像技术在腹部扫描中的应用
能谱成像 技术具有 降低剂量 、抑制 噪声、重建 单能 图像 、定量分 析等特 点 ,已逐渐 应用于临床 [ I 。 ] 。而在能谱成 像扫描技术 中选 择最佳 参数 ,才能发挥其优势 。本研 究运用宝石 能谱C T X  ̄ 腹部 扫描 选择最佳 扫描参数 ,进行单能量 图像重建 、A s i R 重 建 ,进行c 1 值 、S D 值、剂量 C I D I v o 啪D I P l 分析 比较。为能谱成像扫描技术选择最佳参数提供参考。 1 资料 与方 法 1 . 1资料 :资料选 取2 0 1 2 年2 月至8 月 因不 同临床指 征进 行腹部 C T 扫
察是否扫描完整以及如果进行研究时,作为混合能量的对 比。第二 组 ,7 0 k e V 图像 ,不带能谱信息( 5 mm ) 。用于摄片及P A C S 传输 ,书写
报告。第三组 ,7 0 k e V图像 ,带能谱信息( 1 . 2 5 或0 . 6 2 5 m m) 。用于 图像 后处理 ,G S 1 分析 。该组 图像 因数据量 大 ,不传输P A C S ,如 需要 薄层 传输 ,可在G S 1 分析 中建立 一组单纯7 0 k e V图像 。 本研 究 尚存一 些不足之 处。本研究 采用 固定 m A s 扫描 ,使用 不 同 比例 迭代 算法 重建 图像 来 比较 图像 噪 声 ,没有 采用 不 同mA s 扫描 进 行不 同比例迭 代算法来 比较扫描 剂量 。另外使 用的G E D i s c o v e r y C T 7 5 0 H D ̄谱 扫描 尚未使用迭代算法 ,无法 比较能谱扫描的剂量 。 参 考 文献 [ 1 】 李 剑颖 , 沈云, 曹会 志, 等宝 石能谱 C T 的体 模 基础 研 究 [ J 】 . C T 影像 杂 志, 2 0 1 0 , 1 1 ( 3 ) : 1 1 ' 1 4 . [ 2 】 石 明国, 张振荣 , 尤志军 . C T 成像技术 的发展 [ J ] . 中国医学装备, 2 0 0 7 ,
宝石能谱CT在肝癌诊断中的研究进展
宝石能谱CT在肝癌诊断中的研究进展袁彪(综述);肖喜刚(审校)【摘要】Liver cancer is a common digestive malignant tumor,and early detection,early diagnosis,early treatment have a very profound impact on the prognosis.Gemstone CT is a new green CT,with the advantages of low radiation dose,high scanning speed,and rich imaging parameters,which can provide a lot of informa-tion for the diagnosis.Gemstone CT provides references for early diagnosis and differential diagnosis of liver cancer with more direct and scientific images,and is a new way for the clinical diagnosis and research.%肝癌是一种常见的消化系统的恶性肿瘤,早发现、早诊断、早治疗对患者的预后具有十分深远的影响。
宝石能谱CT是一种新型的绿色CT,其辐射剂量低,扫描速度快、成像参数丰富等优势。
在疾病的诊断中能提供众多信息等特点。
宝石能谱成像为肝癌的早期诊断、鉴别诊断提供了依据,使图像更直观更科学,为临床诊断及科研提供了一个新的途径。
【期刊名称】《医学综述》【年(卷),期】2015(000)011【总页数】3页(P2044-2046)【关键词】肝癌;体层摄影;电子计算机X线断层扫描技术;宝石能谱成像【作者】袁彪(综述);肖喜刚(审校)【作者单位】哈尔滨医科大学附属第一医院 CT室,哈尔滨150001;哈尔滨医科大学附属第一医院 CT室,哈尔滨150001【正文语种】中文【中图分类】R445.3CT自问世以来,其已成为一种常见的腹部检查方式,但因腹部组织器官多、生理状态多样、病理变化复杂、疾病谱广、病变复杂以及CT征象多等,导致疾病的诊断和鉴别诊断相对困难[1]。
腹部血管CT低剂量扫描迭代算法重建在临床中应用的可行性研究
腹部血管CT低剂量扫描迭代算法重建在临床中应用的可行性研究发表时间:2016-06-20T10:15:24.977Z 来源:《心理医生》2015年23期作者:赵赛峰[导读] CT低剂量扫描迭代算法重建技术对腹部血管进行造影检查效果良好,可减少CT检查的辐射剂量,值得推广。
赵赛峰(江苏省启东市人民医院CT室江苏启东 226200)【摘要】目的:研究腹部血管CT低剂量扫描迭代算法重建在临床中应用的可行性。
方法:选取2014年3月至2015年3月接诊的120例行腹部血管CT检查的患者进行研究。
按照检查的先后顺序分为三组进行图像检查的比较分析,A组患者应用常规剂量滤波反投影进行检查,B 组应用低剂量的滤波反投影检查,C组患者则应用CT低剂量扫描迭代算法重建方法进行检查。
分析患者CT检查的CT值、SNR及CNR值进行检查,进而分析检查的主观及客观图像的各项指标状况。
结果:C组的图像主观评分在2分以上的比例(100.00%)明显高于A组(82.50%)和B组(77.50%),差异有统计学意义(χ2=9.6635,P=0.0080)。
C组患者的CT值、SNR及CNR三项指标明显高于A组和B 组,(P<0.05),A组和B组比较无统计学意义(P>0.05)。
结论:腹部血管CT低剂量扫描迭代算法重建在临床中的应用效果良好,值得广泛推广应用。
【关键词】血管造影;低剂量扫描迭代算法;CT;重建【中图分类号】R445 【文献标识码】A 【文章编号】1007-8231(2015)23-0089-02CT检查是腹部血管扫描检查中较为常用的一种手段。
临床研究显示,螺旋CT检查过程中低电流、改变螺距等方式会导致检查图像的噪声增加,进而使得图像质量下降[1]。
本研究拟采用CT低剂量扫描迭代算法重建技术对腹部血管进行造影检查。
现报道如下。
1.材料与方法1.1 一般资料选取2014年3月至2015年3月接诊的120例行腹部血管CT检查的患者进行研究。
宝石能谱CT在腹部病变中应用进展
变化也 同时影响着物质对 x线 吸收。任一物质均具
有 随 x 线 能量 衰 减特 征 吸 收 曲线 ,且 该 x线 吸 收 系 数 可 由其 他任 意 两种 基 物质 特征 吸收 曲线 计算 而 来 。
研究 C T值稳定性 ,发现 6 5 k e V单能量图像 C T值稳
算方法为 :
CT (x ,Y,Z ,E )=D ( X ,Y,z ) Di o d i n e ( X ,Y ,z ) i 。 ( E ) 。 ( E )十
在 该 式 中,
i
。 ( E ) 为 水 x线 吸 收 系 数 ,
定优势 。与传统 1 2 0 k V p 相 比,能谱成像能够同时 获得 ( 4 0~ 1 4 0 ) k e V单能量图像以及物质分离图像 ,
物理学家们提供了水和碘 [ ( E ) 和 i 。 。 ( E ) ] 以及 许多纯物质和混合物质量吸收函数随能量变化曲线 ] 。
水 和碘作 为基 物质 时 ,组 织在 某种 单能 量下 C T值 计
3 能谱 C T成像技术应用
3 . 1 肝 脏病 变 能谱 CT对腹 部小 病灶 检 出 、定 性分 析及 鉴别有
对于传统混合能量图像 ,单能量 图像可以减少硬化伪 影,进行更精准 C T值测量 【 5 ] 。最近一个体模研究证 实,单能量图像可以减少肾囊肿假强化现象 , 并发现 7 0 k e V图像在视觉上和传统 1 2 0 k Vp 混合能量图像类
似 ,且其 图像 质量要 优于 7 8 k e V 图像 】 。Ma t s u mo t o 等 对 单 能 k e V 图像 和 混合 能 量 K V p图像 之 间关
能谱CT智能匹配技术联合自适应迭代重建技术在布加综合征中的应用
能谱CT智能匹配技术联合自适应迭代重建技术在布加综合征中的应用苏蕾;胡丽丽;吴艳;高剑波【期刊名称】《中国医学影像学杂志》【年(卷),期】2018(026)004【摘要】目的探讨能谱CT智能匹配技术联合自适应迭代重建(ASIR)技术对布加综合征图像质量及辐射剂量的影响.资料与方法前瞻性纳入行能谱CT血管成像的120例布加综合征患者,采用随机数字表法分为研究组和对照组,每组60例.研究组采用CT智能匹配技术,对比剂1.6 ml/kg,分别采用滤波反投影(FBP)及ASIR对40~60 keV图像进行重组,获得A、B组图像;对照组采用常规120 kVp扫描,对比剂1.8 ml/kg,采用FBP重组获得C组图像.比较3组图像的门静脉主干、肝静脉、下腔静脉及肝脏对比噪声比(CNR)及主观评分.结果在40~60 keV水平,B组各部位的CNR值最高,3组间差异有统计学意义(P<0.01).在40 keV水平,C组的主观评分最高,为(3.61±0.53)分;在50~60 keV水平,B组的主观评分最高,分别为(3.67±0.61)分、(3.91±0.66)分,差异均有统计学意义(P<0.05).结论通过能谱CT 智能匹配技术可获得与常规扫描相当的辐射剂量,采用ASIR技术既提高了图像质量,又降低了对比剂用量.【总页数】5页(P272-275,284)【作者】苏蕾;胡丽丽;吴艳;高剑波【作者单位】郑州大学第一附属医院放射科,河南郑州 450052;郑州大学第一附属医院放射科,河南郑州 450052;郑州大学第一附属医院放射科,河南郑州 450052;郑州大学第一附属医院放射科,河南郑州 450052【正文语种】中文【中图分类】R543.6;R445.3【相关文献】1.能谱CT单能量成像联合自适应迭代重建技术优化胸部增强扫描图像质量的研究[J], 周悦;董军强;高剑波;侯平;王明月;许瀚2.能谱CT单能量成像联合自适应统计迭代重建技术对兔正常肝脏增强扫描图像质量的影响 [J], 柴亚如;吕培杰;刘杰;闫晓朋;高剑波3.上腹部能谱CT智能匹配技术在提高图像CNR、降低对比剂使用量中的应用 [J], 叶芮英4.个性化低剂量能谱CT冠状动脉成像结合r自适应迭代重建技术的临床应用 [J], 黄州;符平仲;胡玉明;梁炎辉;欧阳可勋;邓凌;何乐为;刘怀忠;郑俭勤5.能谱CT低电压联合迭代重建技术在冠状动脉CTA中的应用 [J], 李帆;王利东因版权原因,仅展示原文概要,查看原文内容请购买。
低毫安结合自适应统计迭代重建(ASiR)在降低腹部血管能谱CT成像辐
R a d i o l P r a c t i c e , Oc t 2 0 1 5 , V o l 3 0 , No . 1 0
1 0 2 3
腹 部 影 像 学
低 毫 安 结 合 自适 应 统 计 迭 代 重 建 ( AS i R) 在 降 低 腹 部 血 管 能 谱 C T 成 像 辐射 剂 量 中 的可 行 性 研 究
( AS i R)u s e d i n u p p e r a b d o mi n a l C T a n g i o g r a p h y( CTA) W ANG Qi n g — g u o, W ANG Z h e n g , Z H OU Z h i - g u o, e t a 1 . De p a r t — me n t o f Ra d i o l o g y , t h e Fi r s t Af f i l i a t e d Ho s p i t a l o f S h a n g h a i J i a o To n g Un i v e r s i t y, S h a n g h a i 2 0 0 0 8 0, P. R. C h i n a
DOI : 1 0 . 1 3 6 0 9 / j . c n k i . 1 0 0 0 — 0 3 1 3 . 2 O 1 5 . 1 0 . 0 1 2
F e a s i b i l i t y o f l o w— t u b e - c u r r e n t g e ms t o n e s p e c t r a l i ma g i n g( GS I )a s s o c i a t e d wi t h a d a p t i v e s t a t i s t i c a l i t e r a t i v e r e c o n s t r u c t i o n
探讨宝石能谱CT在胃癌诊断中的应用价值
探讨宝石能谱CT在胃癌诊断中的应用价值
宝石能谱CT是一种新型的医学影像技术,它利用高能X射线穿透物质产生的光谱信息来获取组织的化学成分,能够提供较传统CT更丰富的组织信息。
在胃癌诊断中,宝石能谱CT的应用价值备受关注。
本文将探讨宝石能谱CT在胃癌诊断中的应用价值,以期为临床医学提供参考。
一、宝石能谱CT在胃癌诊断中的技术原理
宝石能谱CT技术是建立在光子电离效应的基础之上的,其工作原理是利用高能X射线穿透物质产生的光子电离效应,通过测量光子的能量谱信息,得到组织的化学成分信息。
相比于传统CT技术,宝石能谱CT能够提供更精细的组织成分信息,有望在肿瘤诊断中发挥重要作用。
1. 提供更丰富的组织信息
宝石能谱CT能够提供肿瘤组织的化学成分信息,可以更准确地判断肿瘤的类型和恶性程度。
在胃癌诊断中,通过分析肿瘤组织的化学成分,可以更精确地判断肿瘤的生长状态和转移情况,有助于制定更合理的治疗方案。
2. 提高诊断准确性
3. 提供更好的术前评估
随着宝石能谱CT技术的不断进步和成熟,其在肿瘤治疗监测和疗效评估中也有望发挥更大的作用。
通过跟踪肿瘤组织的化学成分变化,可以更好地评估治疗的效果和预测肿瘤的发展趋势,为临床治疗提供更有效的参考。
为了更好地发挥宝石能谱CT在胃癌诊断中的应用价值,还需要加强相关技术和临床研究,提高宝石能谱CT的成像质量和临床可操作性,进一步探讨其在胃癌诊断和治疗中的潜在应用价值,为临床医学提供更多的可靠依据。
探讨宝石能谱CT在胃癌诊断中的应用价值
探讨宝石能谱CT在胃癌诊断中的应用价值宝石能谱CT是一种新型的医学影像技术,通过利用宝石闪烁体的能量分辨特性,可以获取高分辨率的能谱图像,为胃癌诊断提供了新的工具和方法。
下面将详细探讨宝石能谱CT在胃癌诊断中的应用价值。
宝石能谱CT可以提供更准确的胃癌诊断结果。
传统的CT扫描通常只能提供胃腔的形态结构信息,对于早期胃癌或胃内浸润性癌的诊断有一定局限性。
而宝石能谱CT可以通过测量X射线入射体与组织之间的能量转移,提供更丰富的组织特征信息。
通过分析能谱图像,可以检测胃癌病灶的微小改变,进一步提高诊断的准确性。
宝石能谱CT可以进行定量分析,有助于评估胃癌的恶性程度。
宝石能谱CT可以测量肿瘤组织的X射线吸收、散射和衰减等特征,通过分析这些能量分辨的参数,可以评估胃癌的恶性程度和浸润程度。
测量肿瘤组织的血管密度、血管直径等参数,可以评估肿瘤的血供情况,进一步判断肿瘤的恶性程度。
宝石能谱CT可以提供三维图像重建,有助于胃癌的定位和分期。
宝石能谱CT可以获取多角度、多方向的能谱图像,通过这些图像可以进行三维图像重建。
三维图像可以提供更准确的胃癌定位,有助于指导手术切除范围的确定。
通过超分辨重建算法,宝石能谱CT 还可以实现高分辨率的胃癌图像,进一步提高分期的准确性。
宝石能谱CT具有较低的辐射剂量和较短的扫描时间。
宝石能谱CT利用宝石闪烁体的特性,可以更高效地吸收和转换X射线能量,从而降低了胃癌患者的辐射剂量。
宝石能谱CT的扫描时间也相对较短,可以减少扫描过程中的不适感,提高患者的接受度。
宝石能谱CT在胃癌诊断中具有较高的应用价值。
它可以提供更准确的诊断结果,评估胃癌的恶性程度,定位和分期胃癌,同时具有较低的辐射剂量和较短的扫描时间。
目前宝石能谱CT技术还处于研究阶段,需要进一步的临床验证和推广应用,以进一步发挥其在胃癌诊断中的潜力。
能谱CT单能量技术结合低对比剂在腹部动脉血管成像中的临床应用价值
M M I MONTHLY Vol28No.8Aug.2019—1698—能谱CT单能量技术结合低对比剂在腹部论著M M I 动脉血管成像中的临床应用价值1.陕西中医药大学医学技术学院2.陕西中医药大学附属医院医学影像科(陕西咸阳712000)常荷-田骞S张喜荣「2,魏卓-张俊-吴俊芳|【摘要】目的:探讨能谱低单能量图像结合低对比剂方案在上腹部动脉血管成像中的应用价值。
方法:使用GE公司宝石能谱CT(Discovery C1750HDCT),选取44例临床怀疑上腹部病变患者行上腹部增强扫描,将患者随机分为两组,其中A组(低对比剂组)采用GSI-60ke V增强扫描,对比剂碘浓度350mgI/kg,B组(对照组)采用常规120kVp增强扫描,对比剂碘浓度500mgI/kg,用GSI Viewer后处理软件重建两组动脉期图像,测量各组腹主动脉、肝固有动脉、脾动脉及竖脊肌的CT值和标准差(Standard Deviation,SD),计算腹主动脉、固有动脉和脾动脉与竖脊肌间的对比噪声tb(Contrast to Noise Ratio,CNR);由2名经验丰富的影像诊断医生分别对肾动脉进行盲法评分。
采用两独立样本t检验及Wilcoxon秩和检验对结果进行分析。
结果:两组间性别、年龄、BMI之间没有统计学差异(P>0.05)o A组图像评分高于B组(Pv0.05)。
A组对比剂浓度较B组减少150mgl/kg o A组腹主动脉CT值及CNR明显高于B组,差异有统计学意义(PV0.05)。
两组肝固有动脉及脾动脉CT值及CNR差异无统计学意义(P>0.05)o两组竖脊肌的SD值、有效辐射剂量差异无统计学意义(P>0.05)o结论:在相同辐射剂量的条件下,能谱低单能量图像结合低对比剂用量在腹部动脉血管显像中,优于或等同于常规增强扫描。
关键词:能谱成像;单能量;对比剂;CT血管成像Clinical Application Value of Energy Spectrum CT Combined with Low Contrast Agenton Abdominal Artery AngiographyChang He1,Tian Qian2,Zhang XiRong12,Wei Zhuo1,Zhang Jun1,Wu Junfang11.College of Medical Technology,Shaanxi University of Chinese Medicine;2.Department of Medical Imaging,Affiliated Hospital of Shaanxi University of Chinese Medicine(Xianyang,Shaanxi712000)[Abstract]Objective:To evaluate the clinical value of combining60keV images in spectral CT with lower contrast dose protocol of350mgI/kg in abdominal CT angiography(CTA).Methods:44contrast-enhanced abdominal CT patients were randomized into2groups:group A(n=22)using spectral CT with350mgI/kg contrast injection protocol;group B(n =22)using conventional120kVp with500mgI/kg.Reconstruction of two groups of arterial phase images with GSI Viewer post一processing software.CT number of the abdominal aorta,properhepatic artery,splenic artery and erector spinae and standard deviation(SD)of erector spinae on the120kVp and60keV spectral CT images were measured.Contrast-noise-ratio(CNR)for abdominal aorta,properhepatic artery and splenic artery was calculated.The renal artery was blindly scored by two experienced imaging diagnosticians.The results were analyzed using two independent sample t-tests and Wilcoxon rank sum test.Results:There was no significant difference in gender,age,and BMI between the two groups(P>0.05).The image score of group A is higher than the group B(p<0.05).The CT number and CNR for abdominal aorta in the 60keV/350mgI/kg spectral images were statisticaDy higher than the120kVp/500mgI/kg images(p<0.05).However,CT number and CNR for the properhepatic artery and splenic artery were statistically the same(p>0.05).There was no difference in SD of erector spinae between the2groups.Conclusion:The60keV spectral images in combination with lower contrast injection protocol provide better or equal image quality in abdominal CTA as the120kVp images with similar radiation dose but30%lower contrast dose.Key Words:Spectral imaging;Single energy;Contrast medium;CT angiography——1699一《现代医用影像学》2019年8月第28卷第8期CT增强扫描及重建技术已广泛应用于腹部疾病的诊断及鉴别诊断⑴。
《2024年宝石能谱CT成像对结直肠癌病理分型及与溃疡性结肠炎鉴别的应用价值》范文
《宝石能谱CT成像对结直肠癌病理分型及与溃疡性结肠炎鉴别的应用价值》篇一摘要:本文旨在探讨宝石能谱CT成像技术在结直肠癌病理分型及与溃疡性结肠炎鉴别诊断中的应用价值。
通过对比分析,我们发现宝石能谱CT成像能够准确反映结直肠癌的病理特征,并有效地区分结直肠癌与溃疡性结肠炎,为临床诊断和治疗提供重要依据。
一、引言结直肠癌是一种常见的消化道恶性肿瘤,其发病率逐年上升。
早期准确诊断和分型对于制定有效的治疗方案及改善患者预后具有重要意义。
近年来,宝石能谱CT成像技术因其高分辨率、多参数成像等优势,在结直肠癌诊断中得到了广泛应用。
本文将重点探讨宝石能谱CT成像在结直肠癌病理分型及与溃疡性结肠炎鉴别中的应用价值。
二、材料与方法1. 研究对象选取经病理证实为结直肠癌及溃疡性结肠炎的患者,共收集病例XX例,其中结直肠癌患者XX例,溃疡性结肠炎患者XX 例。
2. 检查方法采用宝石能谱CT成像技术,对患者进行腹部扫描。
扫描参数包括层厚、层间距、扫描范围等,以确保图像质量。
3. 图像分析由两位具有丰富经验的放射科医师对图像进行分析,记录肿瘤位置、大小、形态、边界等特征,以及与周围组织的关系。
同时,对结直肠癌的病理分型进行评估。
三、结果1. 结直肠癌病理分型通过宝石能谱CT成像,可以清晰地显示结直肠癌的肿瘤形态、边界及与周围组织的关系。
根据肿瘤的细胞学特征、浸润深度及淋巴结转移等情况,将结直肠癌分为鳞状细胞癌、腺癌、黏液腺癌等类型。
宝石能谱CT成像能够准确反映这些病理特征,为临床医生制定治疗方案提供依据。
2. 结直肠癌与溃疡性结肠炎的鉴别宝石能谱CT成像在鉴别结直肠癌与溃疡性结肠炎方面具有重要价值。
结直肠癌的CT表现通常为不规则的肿块,边界不清,伴有周围组织的浸润和淋巴结转移。
而溃疡性结肠炎则表现为肠道壁的增厚、溃疡形成及周围组织的炎症反应。
通过对比分析,宝石能谱CT成像可以有效地区分两者,为临床诊断提供重要依据。
四、讨论宝石能谱CT成像技术在结直肠癌诊断中具有较高的应用价值。
探讨宝石能谱CT在胃癌诊断中的应用价值
探讨宝石能谱CT在胃癌诊断中的应用价值
宝石能谱CT是一种新型的医学影像技术,它结合了计算机断层扫描(CT)和宝石能谱成像技术。
它通过对物质的物理特性进行分析,可以提供更丰富的信息,以辅助医生准确诊
断胃癌。
宝石能谱CT可以提供更精确的解剖学信息。
传统的CT扫描可以展示组织和器官的形
态结构,但对于胃癌的检测和定位可能不够准确。
而宝石能谱CT可以通过不同能谱的分析,进一步展示不同组织和器官的成分差异,以更准确地识别和定位胃癌病灶。
宝石能谱CT可以识别不同组织之间的代谢差异。
胃癌是由恶性肿瘤细胞组成的,其代谢活性普遍较高。
宝石能谱CT可以通过分析不同组织的能谱信息,了解组织的代谢情况,从而帮助医生区分正常组织和癌细胞,提高胃癌的诊断准确度。
宝石能谱CT还可以提供功能性信息。
它可以通过分析不同能谱的分布情况,了解胃癌病灶周围的血流情况,从而评估病灶的侵袭深度和转移情况,帮助医生进行临床分析和决策。
宝石能谱CT还可以提供药物治疗效果的监测。
胃癌的治疗往往需要辅助化疗或放疗,而药物的分布情况和代谢过程对治疗效果有很大影响。
宝石能谱CT可以通过分析不同能谱的分布和代谢信息,监测药物在病灶区域的浓度和代谢速率,帮助医生评估治疗效果,调
整治疗方案。
宝石能谱CT在胃癌诊断中的应用具有很大的潜力。
它可以提供更丰富的解剖学、代谢和功能性信息,帮助医生更准确地诊断和评估胃癌病情,选择合适的治疗方案,并监测治
疗效果。
宝石能谱CT技术仍处于发展初期,还需要进一步的研究和应用验证,以充分发挥其在胃癌诊断中的应用价值。
宝石能谱CT对肝硬化性腹腔积液及癌性腹腔积液的鉴别价值
宝石能谱CT对肝硬化性腹腔积液及癌性腹腔积液的鉴别价值宝石能谱CT技术在肝硬化性腹腔积液与癌性腹腔积液鉴别中的价值摘要:肝硬化性腹腔积液与癌性腹腔积液是临床上常见的两种疾病,鉴别其性质对指导临床治疗具有重要意义。
宝石能谱CT技术作为近年来新兴的影像学方法,在肝硬化性腹腔积液与癌性腹腔积液的鉴别上具有很大的潜力。
本文旨在探讨宝石能谱CT技术在鉴别肝硬化性腹腔积液与癌性腹腔积液方面的价值,并提出了未来的研究方向。
一、背景肝硬化性腹腔积液与癌性腹腔积液是常见的腹腔积液疾病,其鉴别对于指导临床治疗和预后评估具有重要意义。
传统的影像学方法,在鉴别肝硬化性腹腔积液与癌性腹腔积液方面存在一定的局限性,因此需要新的影像学技术来提高诊断准确性。
二、宝石能谱CT技术简介宝石能谱CT技术是一种基于能量谱的影像学方法,其原理是利用宝石能谱探测器对X射线的能量进行准确测量,进而获取不同能量的图像。
相较于传统的CT技术,宝石能谱CT技术可以提供更多的图像信息,特别是对软组织和血管结构的显示更加清晰。
三、宝石能谱CT技术在鉴别价值的研究1. 血管影像通过宝石能谱CT技术可以获取更精确的血管成像,包括肝动脉、门静脉等,这有助于判断腹腔积液的来源。
肝硬化性腹腔积液多数源于门静脉高压引起的腹水积聚,而癌性腹腔积液多数由肿瘤侵犯引起,两者的血供特点是不同的。
2. 肝组织影像宝石能谱CT技术可以准确显示肝脏的组织结构,包括肝脏的灌注情况和纤维化程度。
通过分析肝脏的CT值以及纹理特征,可以鉴别肝硬化性腹腔积液和癌性腹腔积液。
3. 腹腔积液成分宝石能谱CT技术可以定量分析腹腔积液的成分,如腹水中的蛋白质、细胞等,通过比较不同组织成分的能谱图像,可以判断腹腔积液的性质。
四、未来的研究方向尽管宝石能谱CT技术在鉴别肝硬化性腹腔积液与癌性腹腔积液方面显示出巨大的潜力,但目前相关研究还相对较少。
未来的研究方向可以从以下几个方面展开:1. 扩大样本量,进一步验证宝石能谱CT技术在鉴别腹腔积液方面的准确性和可靠性。
探讨宝石能谱CT在胃癌诊断中的应用价值
探讨宝石能谱CT在胃癌诊断中的应用价值宝石能谱CT是近年来发展起来的一种新型医学影像技术,它基于X射线的物质成分无损检测技术,能够提供比传统CT更为准确的组织成分信息。
相较于传统的CT技术,宝石能谱CT可以实现对物质成分的定量化分析,提高了对病灶的诊断准确性和灵敏度。
在胃癌诊断中,宝石能谱CT可以检测肿瘤组织的特征成分,对胃癌的早期诊断和鉴别诊断具有重要的临床意义。
宝石能谱CT在胃癌鉴别诊断中也具有显著的优势。
与正常组织相比,肿瘤组织具有独特的成分和密度特征,而传统的CT技术难以准确鉴别出这些微小的差异。
而宝石能谱CT可以通过对肿瘤组织的成分进行精确分析,能够区分出肿瘤组织和正常组织之间的微小差异,实现对胃癌的准确鉴别诊断。
这对于胃部其他疾病与胃癌的区分具有重要的临床意义。
宝石能谱CT在指导胃癌治疗方案选择和疗效评价中也具有重要作用。
在胃癌的治疗过程中,宝石能谱CT可以对肿瘤组织的成分进行动态监测,帮助医生调整治疗方案,并在治疗后评价疗效。
这种动态的成分分析和量化技术,使得宝石能谱CT在胃癌个体化治疗中发挥了越来越重要的作用。
宝石能谱CT在胃癌诊断中具有明显的应用价值和临床意义。
其对胃癌早期诊断和鉴别诊断具有更高的准确性和敏感性,可以指导治疗方案的选择和疗效的评价。
当前宝石能谱CT技术还存在一些局限性,例如成本较高、设备复杂、操作要求高等。
随着技术的不断进步和临床的积累,相信宝石能谱CT在胃癌诊断中的应用将会得到更多的认可和推广。
在未来,我们期待宝石能谱CT技术能够更加普及,使更多的患者受益于这一先进的影像技术。
希望通过技术创新和临床研究,不断提高宝石能谱CT的成像质量和数据分析能力,使其在胃癌诊断中发挥出更大的价值。
相信在不久的将来,宝石能谱CT将成为胃癌诊断的重要技术手段,为患者提供更加准确和可靠的医学影像诊断服务。
迭代重建技术在CT上腹部低剂量扫描中的应用效果及价值研究
迭代重建技术在CT上腹部低剂量扫描中的应用效果及价值研究张信起;王宁【期刊名称】《检验医学与临床》【年(卷),期】2017(14)20【摘要】Objective To observe the application effect and value of iterative reconstruction technique in upper abdominal low-dose CTscanning.Methods Sixty patients with abdominal CT scanning in the hospital from June 2015 to September 2016 were se-lected and randomly divided into the control group(n=30)and observation group(n=30).The control group conducted the conven-tional dose abdominal scan at 120 kV and 250 mAs.The obtained images were reconstructed by adopting the filter reflex images. The observation group conducted the upper abdominal low-dose scan under the tube voltage of 120 kV and tube current of 250-270 mAs and at a interval of 60mAs reduced scan condition.The obtained images were reconstructed by iterative technique.Then the application effect of iterative reconstruction technique in upper abdominal low-dose CT scanning was analyzed.Results The cases number of subjective score 1,2 and 3 points for image quality in the observation group was lower than that in the control group, difference was statistically significant(P<0.05);The cases number of subjective score 4 points for image quality in the observation group was more than that inthe control group,difference was statistically significant(P<0.05);the obtained values of image noise, spinal erector muscle noise and abdominal wall fat noise in the observation group were less than those in the control group,the difference was statistically significant(P<0.05);The CT dose index,CT dose length product and effective radiation dose level after iterative reconstruction technique treatment in the observation group were lower than those in the control group,the difference was statistically significant(P<0.05).Conclusion Adopting the iterative technique reconstruction in upper abdominal CT scanning has an ideal effect,can reduces the image noise and radiation dose,moreover the radiation dose reduction by 35% can still obtain the cor-responding image quality by the conventional dose,which is worthy to be promoted and applied.%目的观察迭代重建技术在CT上腹部低剂量扫描中的应用效果及价值.方法选取2015年6月至2016年9月该院收治的上腹部CT扫描患者60例,分为对照组(n=30)和观察组(n=30).对照组在120 kV、250 mAs下进行常规剂量腹部扫描,获得的图像采用滤波反射影进行重建;观察组在管电压120 kV、管电流于250~70 mAs每次间隔60 mAs减低扫描条件下行上腹部低剂量扫描,获得的图像采用迭代技术进行重建,分析迭代重建技术在CT腹部低剂量扫描中的应用效果.结果观察组图像质量主观评分为1分、2分及3分患者例数低于对照组,差异有统计学意义(P<0.05);观察组图像质量主观评分4分患者例数多于对照组,差异有统计学意义(P<0.05);观察组获得图像中噪声、竖脊肌噪声及腹壁脂肪噪声值少于对照组,差异有统计学意义(P<0.05);观察组迭代重建技术处理后CT剂量指数、CT剂量长度乘积及有效辐射剂量水平低于对照组,差异有统计学意义(P<0.05).结论上腹部CT扫描患者采用迭代技术重建效果理想,能降低图像噪声及辐射剂量,且辐射剂量降低35% 仍能获得与常规剂量相对的图像质量,值得推广应用.【总页数】3页(P3051-3053)【作者】张信起;王宁【作者单位】河北医科大学第二附属医院放射科,石家庄050000;河北医科大学第二附属医院放射科,石家庄050000【正文语种】中文【相关文献】1.256层iCT第4代混合迭代重建技术在胸部低剂量扫描中的应用评价 [J], 王博成;薛杨;苏潇;梅云婷;吴利忠;赵江民2.iDose4迭代重建技术在腰椎外伤CT低剂量扫描中的应用 [J], 吴金花;饶慧敏;董国斌;哈若水3.宽体探测器CT低剂量扫描联合迭代重建技术在先天性心脏病患儿诊断中的应用价值 [J], 樊云; 刘娜4.SAFIRE不同级别迭代重建技术在头颈部CTA低剂量扫描中的应用 [J], 梁卡丽; 杨琴; 何其舟; 戴贵东5.低剂量扫描联合迭代重建CTA在颈部疾病患者中的应用效果及价值研究 [J], 陈其锋;林梓朗;杨宇凌因版权原因,仅展示原文概要,查看原文内容请购买。
自适应统计迭代重建技术下宝石能谱CT冠状动脉成像最佳单能量影响
²临床论著²自适应统计迭代重建技术下宝石能谱CT冠状动脉成像最佳单能量影响因素分析张迎1宋娟2孙磊2【摘要】目的探讨自适应统计迭代重建技术(ASIR)下宝石能谱CT冠状动脉成像最佳单能量成像的影响因素。
方法收集石河子大学医学院第一附属医院2016年1月1日至3月31日拟行冠状动脉CT成像患者90例,所有患者均采用宝石能谱CT双能量扫描模式,扫描后原始数据均采用自适应统计迭代重建技术,传输至GE AW4.6工作站,采用GSI Viewer 软件,分别选取肌肉、脂肪及心肌三种不同背景测量冠状动脉左前降支、左回旋支及右冠状动脉最佳单能量,分析三种不同背景下冠状动脉最佳单能量是否存在差异;并且对病例进行性别、体质量指数分组,分析各组间三种不同背景下最佳单能量是否存在差异。
结果肌肉、脂肪及心肌三种不同背景下冠状动脉最佳单能量在左前降支[(66.68±0.70)keV vs.(69.71±0.87)keV vs.(64.74±0.63)keV]、左回旋支[(66.67±0.65)keV vs.(69.80±0.62)keV vs.(64.90±0.71)keV]及右冠状动脉[(66.64±0.78)keVvs.(69.64±0.70)keV vs.(64.96±0.60)keV]差异均有统计学意义(均P<0.05);以肌肉为背景,男性组与女性组冠状动脉左前降支[(66.43±0.93)keV vs.(66.41±0.79)keV]、左回旋支[(66.44±0.94)keV vs.(66.46±0.84)keV]、右冠状动脉[(66.55±1.00)keV vs.(66.54±0.84)keV]最佳单能量值差异无统计学意义(均P>0.05);肌肉背景下,体质量指数正常组、超重组及肥胖组冠状动脉在左前降支[(66.69±0.67)keV vs.(66.73±0.78)keV vs.(66.85±0.62)keV]、左回旋支[(66.48±1.00)keV vs.(66.50±1.00)keV vs.(66.62±1.09)keV]、右冠状动脉[(65.94±0.59)keV vs.(65.97±0.57)keV vs.(65.97±0.63)keV]最佳单能量值差异有统计学意义(均P<0.05)。
探讨宝石能谱CT在胃癌诊断中的应用价值
探讨宝石能谱CT在胃癌诊断中的应用价值
宝石能谱CT(Gemstone Spectral Imaging)是一种新型的医学影像技术,结合了光谱CT和宝石探测器的优势,可以提供更为准确和详细的组织信息。
胃癌是全球范围内常见的恶性肿瘤之一,其早期诊断对于治疗和预后具有重要意义。
本文将探讨宝石能谱CT在胃癌诊断中的应用价值。
宝石能谱CT可以提供更清晰的图像质量。
传统的CT扫描主要依靠X射线的吸收能力来获取影像信息,而宝石能谱CT则引入了能谱敏感的宝石探测器,能够测量不同能量范围内的光谱信息,从而获得更为精确和详细的图像。
这种技术可以减少伪影和扫描深度的限制,提高对胃癌病灶的检测和定位的准确性。
宝石能谱CT可以提供多种组织特征的定量参数。
宝石能谱CT不仅可以提供传统CT图像,还可以提供多种组织特征的定量参数,如血管成分比例、钙化程度、脂肪含量等。
这些参数可以反映胃癌病灶的生物学特性和组织结构特征,有助于判断胃癌的分期和预测预后,并可辅助临床医生在手术前制定更合理的治疗方案。
宝石能谱CT具有低剂量辐射的优势。
由于胃癌患者通常需要接受多次CT扫描进行随访和治疗评估,长期暴露于辐射会增加患者的健康风险。
而宝石能谱CT采用了低剂量辐射的扫描方式,可以减少对患者的辐射暴露,从而更加安全可靠。
宝石能谱CT在胃癌筛查方面具有广阔的应用前景。
胃癌在早期往往没有明显的症状,常常被忽视或误诊,等到病情发展到晚期时治疗难度大。
而宝石能谱CT具有高分辨率和高对比度的优势,可以更早地发现胃癌病变,并可以通过定量参数评估其恶性程度,为早期诊断和筛查提供有力支持。
探讨宝石能谱CT在胃癌诊断中的应用价值
探讨宝石能谱CT在胃癌诊断中的应用价值胃癌是一种常见的恶性肿瘤,临床诊断和治疗面临着很大的挑战。
传统的影像学诊断方式,如胃镜和CT等,存在诊断效果差、侵入性强、不适合广泛应用等问题。
随着宝石能谱CT技术的发展,人们开始关注它在胃癌诊断中的应用价值。
宝石能谱CT是一种新型的影像诊断技术,其使用的是钨靶取代传统的铜靶,钨的原子序数高于铜,产生更多的中心谱线,增加了对低原子序数元素的检测能力。
此外,宝石能谱CT还可实现单次扫描的多层次成像,提高了胃癌诊断的准确性和可靠性。
宝石能谱CT的主要应用是在胃癌初筛和早期诊断中。
由于胃癌早期症状不明显,常常被忽视或误诊,导致病情进一步恶化。
而宝石能谱CT可以提供高精度的三维重建图像,对胃壁浸润、淋巴结转移及转移病灶的定位等方面具有明显优势,可以帮助医生及早发现胃癌病变,提高早期诊断的准确率。
另外,宝石能谱CT还具有检测胃癌复发的特点。
在切除部分或全部胃肠道后,胃癌复发的可能性仍然较高。
传统影像学检查方法对于复发病灶的准确定位不够精确,但宝石能谱CT技术可以检测低密度病变和肿瘤周围的淋巴结转移,帮助医生更好地判断是否存在胃癌复发。
最后,宝石能谱CT还能够评估胃癌患者治疗效果。
通过比较治疗前后宝石能谱CT图像的变化,可以判断治疗的有效性,为治疗方案的调整提供参考。
总的来说,宝石能谱CT技术在胃癌诊断中具有广泛的应用前景和潜力。
它能够提高胃癌早期诊断的准确度,对排除或确定胃癌复发病灶具有重要意义,对于评估治疗效果也有一定的参考价值。
未来随着宝石能谱CT技术的不断完善和发展,其在胃癌诊断领域的应用将更加广泛和深入。
迭代重建技术在临床低剂量腹部CT扫描中的应用进展
随 着 汁算 机技 术 的 发 展 及 临 床 对 于 低 剂 量 C T的 不 断 努
力 ,近 几年 , I R成为临床 医用 C T的 销 售 商 们 和 临床 医 生 的
理使用低剂 量( A L A R A — p r i n c i p l e ) ” 的基本 原则 , 强 在保 证 l 临床诊 断 的 前 提 下 , 使 辐 射 刹 量 保 持 在 合 理 的尽 可能 低 的 水
综 述
V E O) ; 东 芝 公 司的适 应 性 迭 代 剂 量减 低 技 术 ( A d a p t i v e i t e r a —
t i v e d o s e r e d u c t i o n , AI D R) ; 飞利 浦 公 司 的 i D o s e : 两 门 子公 _ 几 ]
的数 据 空 间不 同 , 可将 这 些 技 术 分 为 3类 :
2 . 1 只 在 图像 数 据 空 间进 行 I R
1 CT 图像 重 建 技 术
C T图像 的重 建算 法 主要 包 括 解 析重 建 算 法 和 I R 算 法 。 滤波反投 影重建技术 ( F i l t e r e d b a c k p r o j e c t i o n , F B P ) 属
如 I R I S 。 I R I S对 原 始 数据 按 照 F B P重 建 后 生成 一 次主
期、 延 迟期 ) , 与其他检查 部位相 比 , 病 人 接 受 的 辐 射 剂 量 会 成 倍 增 加 ,所 以腹 部 C T检 查 有 必 要 采 用 低 剂量 扫描 方式 。 近 几年 ,为 厂 改善 C T 图像 质 吊 和 降低 辐射 剂黾 ,迭 代 重 建 ( h e r a t i v e r e c o n s t r u c t i o n , 1 R) 技 术 逐 渐 应 用 于 C T 像 的 雨 建 ,本 文 就 其 相 关 原 理 及 其 在 临 床腹 部 C T的应 用 价 值 进 行
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
2 0 0 0 , 2 0( 4 ) : 3 6 7 — 3 7 2 .
山东医药 2 0 1 5年第 5 5 卷第 3 5
宝 石 能谱 C T低 电压 联 合 自适 应 性 统计 迭 代 重 建 在 腹 部 扫 描 中的应 用
杜海 , 张浩 亮 , 刘智 君 , 徐彦东, 贺 利明 。 耿 明明 , 刘慧 , 苏云 龙 ( 鄂 尔多斯 市 中心 医院 , 内蒙古鄂 尔多斯 0 1 7 0 0 0 )
~
2 8 、 >2 8 ) 将每组分 为 3个亚组 ( A组分为 A 1 、 A 2 、 A 3组 , B组分为 B 1 、 B 2 、 B 3组 ) 。记 录各亚组剂量报告 中 C T剂
量容积指数 ( C T D I v o 1 ) 及剂量长度乘积 ( D L P ) , 并计算有效剂量 ( E D) ; 测量腹 主动脉 、 门静脉 血管腔 内的 c T值 , 并 计算 以上血管 的信号 噪声 比( S N R) 和对 比噪声 比( C N R) ; 从肠系膜动脉 的清晰度 、 门脉分支 的清晰度 、 图像整体 质
ห้องสมุดไป่ตู้
组 比较 , 主动脉 c T值 、 门静脉 c T值增大 ( P均 < 0 . 0 5 ) 。A1 、 B 1组肠 系膜 血管清晰 度 、 门静 脉分支 的清 晰度 、 图像
整体质量 、 主观噪声评分 比较 , P均 > 0 . 0 5 , 其各 自相应秩和检验量为 4 8 6 、 4 7 5 、 5 0 2 . 5 、 3 7 0 . 7 5 ; A 2 、 B 2组肠 系膜 血管
[ 7]J i a n g K,C h e n XZ ,X i a Q,e t 1.C a o s t — e f f e c t i v e n e s s a n a l y s i s o f
e a r l y v e n o — v e n o u s h e mo l f l t r a t i o n f o r s e v e r e a c u t e p a n e r e a t i t i s i n
> 0 . 0 5 , 其各 自相应秩和检验量为 1 4 0 、 1 3 0 、 1 6 1 、 1 1 8 。结论 低 电压腹部扫描能 明显降低辐射剂量 , 提高血管 内碘 浓度 , 结合 自适应性统计迭代重建 , 可以降低图像噪声 , 改善图像 质量 , 满足临床诊断要求 。 关键词 : 低 电压 ; 迭代重建 ; 体层摄影术 ; X线计算机
量、 主观噪声评分 四个 方 面对 图像 进 行 主观 评 价。结 果 与 B 2组 比较 , A 2组 C T D I v o l 、 D L P 、 E D减 小 ( P均 < 0 . 0 5 ) ; 与B 3组 比较 , C T D I v o l 、 D L P 、 E D减小 ( P均 < 0 . 0 5 ) 。与 B 1组 比较 , A 1 组 主动脉 c T值 、 门静脉 c T值 、 门静 脉 C N R增大 ( P均 <0 . 0 5 ) ; 与B 2组 比较 , A 2组主动脉 C T值 、 主动脉 C N R、 门静脉 C T值增 大( P均 <0 . 0 5 ) ; 与B 3
清 晰度 、 门静脉分支 的清晰度 、 图像 整体 质量 、 主 观噪声 评分 比较 , P均 > 0 . 0 5 , 其各 自相应 秩 和检 验量 为 1 3 1 6、
1 3 1 6 、 1 3 8 5 . 5 、 1 2 2 3 ; A 3 、 B 3组肠 系膜血管清 晰度 、 门静脉分支 的清 晰度 、 图像 整体 质量 、 主观 噪声 评分 比较 , P均
摘要 : 目的 影响 。方法
观察宝石 能谱 C T低 电压联合 自适应性 统计迭代 重建在腹部 扫描 中的应用 价值及对 图像质 量 的
2 0 0例行 上腹部增 强检 查的患者随机分为 A、 B两组各 1 0 0例 , A组采用低电压 ( 1 0 0 k V) , 并进行 自适
应性统计迭代重建 4 0 %重建 。B组采用常规 电压 ( 1 2 0 k V) , 并 进行滤 波反投 影 ( F B P ) 重建 ; 另根 据 B MI (<2 3 、 2 3
通信作者 : 张 浩 亮
增加到 3 . 0 m S v_ 】 J 。按 当 前 的 C T使 用 情 况 , 导 致 患癌症 风 险为 2 . 0 % , 而 累 积 风 险对 某 些 患 者 更 高, 特 别是 多期 相扫 描 或 需 要进 行增 加 扫 描 条 件 患
者 。目前 , 减少辐射剂量主要通过降低管电流、 管电 压和 自动毫安控制技术等手段 , 降低辐射剂量会导 致图像噪声增加 , 传统 的滤波反投影 ( F B P ) 重建速
多排 螺旋 C T的广 泛应 用 使人 们 对 医疗 辐 射 暴 露 的关注 也 随之增 加 , 美 国 国家 辐 射 防护 和 测 量 委 员会 与 联 合 国科 学 委 员 会 一 项 研 究 显 示 , 1 9 8 0— 2 0 0 6年美 国人 均诊 疗过 程 中的辐 射剂 量从 0 . 5 os r y
d o i : 1 0 . 3 9 6 9 / j . i s s n . 1 0 0 2 - 2 6 6 X . 2 0 1 5 . 3 5 . 0 2 7
中图分类号 : R 8 1 4 . 1 2
文献标志码 : B
文章编号 : 1 0 0 2 . 2 6 6 X( 2 0 1 5 ) 3 5 - 0 0 7 1 - 0 3