TSOP1136UU1中文资料
SP16系列编程器使用手册说明书
SP16系列编程器使用手册Revision B5使用编程器之前,请仔细阅读本手册,并按要求正确操作编程器,不按要求操作 将会导致编程器损坏,并得不到保修服务!深圳硕飞科技有限公司SHENZHEN SOFI TECHNOLOGY CO.,LTD .WEB: 硕飞科技目录第一章产品介绍∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙3 功能特点∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙3 SP16系列编程器功能对比表∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 4 第二章编程器硬件∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙5 第三章快速使用∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙6 联机模式烧录步骤∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 6 联机烧录模式指示灯状态说明∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙.∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙8 第四章脱机烧录∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙9 下载脱机数据∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙9 脱机运行–手动方式∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙10 脱机运行–自动控制方式∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙10 ATE接口定义∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙10 脱机工作模式状态指示灯∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 11 脱机数据查看∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙11 第五章ISP 模式烧录∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙12 ISP接口∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙12 ISP连接线∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙12 目标芯片连接∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙13 ISP供电模式∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙14 第六章FlyPRO MCP多机控制软件∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙15 功能介绍∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙15 使用方法∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙15 附录一常见问题∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙19 附录二免责声明∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙21 附录三文件修订记录信息∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙22第一章产品介绍功能特点⚫专门针对串行EEPROM / SPI FLASH芯片进行设计,相比于通用编程器速度更快,稳定性更高;⚫USB供电及通讯,无需外接电源。
MITSUBISHI SEMICONDUCTOR PS21265-P AP 说明书
INSULATED TYPEINSULATED TYPEINSULATED TYPE2.052.152.001.85—0.602.100.801101.953.000.067mAV T j = 25°C T j = 125°CI C = 20A, T j = 25°CI C = 20A, T j = 125°C V CE(sat)V EC t on t rr t c(on)t off t c(off)I CESConditionSymbol ParameterLimits Inverter IGBT part (per 1/6 module)Inverter FWDi part (per 1/6 module)Case to fin (per 1 module) thermal grease appliedR th(j-c)Q R th(j-c)F R th(c-f)FMin.THERMAL RESISTANCETyp.Max.——————Unit T j = 25°C, –I C = 20A, V IN = 0V ConditionSymbol ParameterLimits Min.Typ.Max.———0.65——————Unit ELECTRICAL CHARACTERISTICS (T j = 25°C, unless otherwise noted)INVERTER PARTCollector-emitter saturation voltageFWDi forward voltageJunction to case thermalresistance (Note 3)V D = V DB = 15VV IN = 5V Switching timesV CC = 300V, V D = V DB = 15VI C = 20A, T j = 125°C, V IN = 0 ↔ 5V Inductive load (upper-lower arm)Collector-emitter cut-off currentV CE = V CES1.551.651.501.250.300.401.500.50——V µs µs µs µs µs °C/W °C/W °C/WCONTROL (PROTECTION) PARTNote 4:Short circuit protection is functioning only at the low-arms. Please select the external shunt resistance such that the SC trip-level isless than 2.0 times of the collector current rating (20A).5:Fault signal is output when the low-arms short circuit or control supply under-voltage protective functions operate. The fault output pulse-width t FO depends on the capacitance value of C FO according to the following approximate equation : C FO = 12.2 ✕ 10-6 ✕ t FO [F].SymbolI D V FOHV FOLV SC(ref)I INUV DBtUV DBrUV DtUV Drt FOV th(on)V th(off)ParameterConditionLimits Unit Circuit currentFault output voltageShort circuit trip level Control supply under-voltage protection Fault output pulse width ON threshold voltage OFF threshold voltage V D = V DB = 15V V IN = 5V T otal of V P1-V PC , V N1-V NC V UFB -V UFS , V VFB -V VFS , V WFB -V WFS V SC = 0V, F O circuit pull-up to 5V with 10k ΩV SC = 1V, I FO = 1mAT C = –20~100°C, V D = 15V (Note 4)V IN = 5VTrip level Reset levelTrip level Reset levelC FO = 22nF (Note 5)Applied between U P , V P , W P -V PC , U N , V N , W N -V NC————4.9—0.451.010.010.510.310.81.02.10.8———————1.5————1.82.31.47.000.557.000.55—0.950.522.012.012.512.513.0—2.62.1Min.Typ.Max.mA mA mA mA V V V mA V V V V ms V VV D = V DB = 15V V IN = 0V Total of V P1-V PC , V N1-V NC V UFB -V UFS , V VFB -V VFS , V WFB -V WFS T j ≤ 125°CNote 3 : Grease with good thermal conductivity should be applied evenly with a thickness of about +100µm~+200µm on the contact surfaceof DIP-IPM and heat-sink.Input current Contact thermal resistanceINSULATED TYPEINSULATED TYPEINSULATED TYPEINSULATED TYPEINSULATED TYPEINSULATED TYPE。
电动托盘电机型号与功能介绍说明书
A I R C H ALODESTAR XL 2 to 7 1/2 tonn n n n n n n XL AIR 2 to 7 1/2 ton n n n n n nE V E R S P E C I A LOW HEADROOM CHAIN 1 to 24 tonn n Upper Shipyard Hook Lower Shipyard HookSERIES 6331/2 to 5 ton n Frames connected by steel equalizer pin, secured by two nuts on each side n Rugged steel side plates formed to include bumpersCBT1/4 to 5 ton n nn Bridge Crane Kits n Jib Cranesn LodeRail™Systems n Chain Containersn Cord Reelsn Festooning Packagesn Bronze Wheels / Hooks n Zinc Plated Chain / Hooks n Variable Speed Control n Stainless Steel Chain n NEMA Push Button Stations n Infrared Remote Control n Cady Spreader Beams n Plate Clamps nBinders n Herc Alloy Chain Slings n Hooks n Shackles n Hammerloks n Hoist Rings ACCESSORIES & PRODUCTS © 2012 Columbus McKinnon Corporation. All Rights Reserved. Stock # CMPG-0212 SS 5M GK Phone: (800) 888.0985•(716) 689.5400•Fax: (716) 689.5644•In addition to the strong knowledge base exemplified by comprehensive training programs, Columbus McKinnon is one of the only manufacturers supplying complete lifting systems to satisfy unique material handling requirements of users in a variety of environments. From jib cranes and hoists to chain slings, clamps, and related attachments;systems include products that are matched specifically to the lifting needs of the application. Products may also be modified in order to ensure that the proper system is in place for the job.Whether your needs call for a single electric chain hoist or a completely engineered system to outfit your production facility, Columbus McKinnon provides the products and expertise to keep your workforce productive and safe.。
惠普 LaserJet Pro M1136
打印参数
标配打印机语言基于主机打印方式激光打印 打印速度(页/分) 18打印分辨率(dpi)600×600 首页打印时间 8.5自动双面打印有 进纸盒容量 150
复印参数
复印速度(页/分) 18复印分辨率(dpi)300×300 原稿尺寸A4双面复印有
扫描参数
扫描分辨率(dpi) 1200×1200扫描尺寸216 x 297 mm ADF扫描速度高达 6页/分钟存储格式PDF; TIF; BMP; GIF; JPG 平板扫描单元有扫描到PC文件夹有 扫描至USB存储介质有
其他参数
标准附件 HP LaserJet Pro M1136多功能激光一体机、电源线、出纸盒、HP LaserJet黑色体验硒鼓、 Readiris PRO文字识别软件、软件与文档 CD、安装指南、保修指南(适用时)、USB连接线。随机软件基于主 机的打印驱动程序、TWAIN、WIA、扫描到应用程序、XPS驱动程序、Mac驱动程序。
附带电缆有,1根 USB连接线。其他特性支持双面打印。介质尺寸:普通纸,轻质纸,中等重磅纸,重磅纸, 超重磅纸,信头纸,预印纸,彩纸,证券纸,再生纸,粗纸,牛皮纸,信封,明信片
保修一年有限保修。
电气规格
功耗(W)活动375瓦。待机:3.2瓦。睡眠:1瓦(自动关闭)电压220-240V,50Hz
环境参数
惠普公司(Hewlett-Packard,简称HP)是一家来自美国的资讯科技公司,成立于1939年,主要专注于生产 打印机、数码影像、软件、计算机与资讯服务等业务。惠普由斯坦福大学的两位毕业生威廉·休利特及戴维·帕 卡德创办。
主要参数
涵盖功能打印/复印/扫描 主要功能打印 复印速度(页/分)18扫描分辨率(dpi)1200×1200
FESTO IO-Link 产品说明书
All set for automation with IO-Link®Point-to-point!Standardised IO-Link technology (IEC 61131-9) makescommunication with sensors and actuators simple and economical. The result of an evolutionary development, this low-cost connectiontechnology with three or five conductors is used for point-to-point connection without complex wiring and with minimal material requirements.Parameterisation made easy Software-supportedparameterisation of intelligent sensors and actuators via the IO-Link master makes it extremely easy to set andreassign parameters. All descrip-tion files are stored in the central IODD finder database. Theautomatic parameter assignment server function (data storage) following device replacement is an especially convenient feature.Less downtime, increased productivityThe comprehensive exchange of diagnostic and operational data between device and master systems speeds up troubleshooting and forms the basis for condition monitoring systems.Safe investment thanks to standardisationAn international, open and fieldbus-independent IO-Link standard supports existing and future connection concepts.Easier to installUncomplicated wiring of the sensor-actuator combinations with standardised, unscreened cables reduces material costs, simplifies logistics and saves time.Easier communicationMore flexible communication thanks to standardisation, from the control level to the field level, and compatible with Industry 4.0 host environments.IO-Link – the intelligent “last step” in automationIO-Link is not a new bus system, but a new kind of interface which expands fieldbus and Industrial Ethernet systems. IO-Link allows you not only to transmit process data, but also to download parameter data from the control system to the sensor or actuator, and to send diagnostic data in the other direction to the control system.Whereas integrating a fieldbusinterface all the way down to thelowest field level used to be verycostly, digital or analogue valuescan now be transmitted with onlya simple 3- or 5-wire cable – withno special features in terms ofscreening, twisting, impedanceor terminating resistance.The gateway between thefieldbus and one or more IO-Linkslaves is normally provided bya fieldbus device with multipleIO-Link master channels. Insmaller machines or systems,which may not require a fieldbusbecause of their size, the PLCacts as the IO-Link master.What does IO-Link do?• Serial, bidirectional communication interface for sensors and actuators• Simplified commissioning of a wide range of devices based on standardised profiles• Point-to-point connection at field level with master-device communication • Can be used either for simplesensors or for very complexsensor-actuator combinations• One standard connection formeasuring or switchingsensors as well as for fielddevices with a mix of signalsand data• Compatible with standardcables and connectors• Parameter assignment serverfunction (data storage) for thefast and easy replacement ofsensors and actuators. If anIO-Link device fails, the oldsettings are automaticallytransferred to the replacementdevice by the IO-Link master• Device description file IODDfor easy parameterisation onthe PC with a graphical userinterface: https://ioddfinder.What are the key features of IO-Link?A mass of expertiseFesto is a member of all the globally relevant fieldbus/Ethernet organisations as well as AS-Interface and IO-Link. We have been developing fieldbus-capable electronic components for more than 25 years, and we are a global market leader in intelligent pneumatics and in technical basic and further training.All fieldbus/Ethernet, AS-Interface and IO-Link products are suitable for use as “contributors” interms of Industry 4.0. IO-Link offers a clear and machine-readable data structure. Festo offers you a comprehensive IO-Link portfolio for integrated solutions from the mechanical system to the cloud.Professional and consistent decentralisation: the compact controller CECC with four IO-Link master ports doesn’t just reduce the cost of installing and networking intelligent sensors and valve terminals. It also provides valuable diagnostic options. The automation system CPX-E with 4-way IOL master in IP20 is a new addition.Economical and efficient installationLow-cost standard cables and IO-Link for valve terminals instead of multi-pin plugs allow simple, decentralised diagnostic messagesand offer distinct technical advantages, such as more flexible installation, improved energy chain feed-through, and optimum adaptation to humid or particularly harsh ambient conditions.Secure processes and data transmissionProportional pressure regulators VPPM or vacuum generators OVEM connected to the IO-Link master do not need a screened analogue cable, making the signal level less prone to interference. Para m eterisation and data storage take place in the IO-Link master (parameter assignment server function), so that devices can be restarted after replacement.Easy integration of complex sensorsThe uniform interface in IO-Link replaces individual sensor connections, e.g. with a mix of analogue and digital signals. That means that even position transmitters SDAT and parame -terisable pressure and flow sensors can be integrated and installed at low cost.Secure: valve terminals with type B portsValve terminals from Festo have a galvanically isolated power supply to the electronics and valves. They communicate using the IO-Link V1.0 and V1.1 protocol with a baud rate according to COM3. And astype B port devices, they ensure that valves can be shut down securely after emergency off.Other IO-Link devices from Festo have a type A port and protocol V1.1.IO-Link benefits with FestoThe benefits of Industry 4.0 and IO-LinkInstallation, parameterisation and diagnostics in peak formDSBF DRRD DSBC DSBGCPV MPA-L VTUB VTOC VTUG SDATElectrical connections Pneumatic connections* Installation system CTEL, bus node CTEU, adapter CAPC for 2 Festo I-Port/IO-Link devicesESG ELGR EPCOCTSL -M8CTSL -M12SCDNOVELCMMO-STCMMO-STSPAESPANSFAHSFAWCompact controller CECC as master (port type B, V1.1)IO-Link and products from Festo• CECC-LK and CECC-S can also be operated as IO-Link devices on any IO-Link master module • For activating electric and pneumatic actuators for small tasks• Stand-alone or in mechatronic solutions via CODESYS V3.5 provided by Festo, with OPC UA for Industry 4.0Features• Hybrid: direct activation and connection of electric and pneumatic actuators via CANopen• Can be integrated into higher-level systems via Modbus/TCP • Compact and with more functionsTerminal CPX (port type B, V1.0)Allows one or more master interfaces for IO-Link devices to be integrated when used as remote I/O or in conjunction with valve terminals.Currently available for:PROFINET SERCOS III EtherNet/IPCoDeSys controller CPX-CEC-V3-5(≥SP7)Features• On-site installation• Control platform to IP65• Integrated in a valve terminal MPA or VTSA• Comprehensive function integration• Simple control of pneumatic or electric actuators• Plus: individual IO-Link third-party devices can be connected in the near/direct vicinity of the valve terminalValve terminal MPA-L (port type B, V1.1)Expandable in individual steps.Features• Light, cost effective andcorrosion-resistant thanksto sub-base with polymertechnology• Wide range of electricalconnection options frommulti-pin plug up to fieldbusthanks to Festo I-Port (IO-Link)and CPX • Low-cost and tamper-proof fixed restrictor with vertical pressure shut-off plateto replace valves during operation, and pressure regulator• Three combinable valve sizes for flow rates of upto 850 l/min, optionallyin polymer or metal designCPX-E modular remote I/O and control systemPowerful and extremely compact system for factory automation focusing on the function of motion control (CODESYS V3). Profinet, EtherNet/IP, EtherCAT or OPC UA for Industry 4.0 are available for integration in existing host environments, plus a 4-way IO-Link master module for system expansion.Features• High performance (Dual Core766 MHz, 512 MB RAM)• Integrated bus masterinterfaces:−EtherCAT master• Integrated bus slave interfaces:−PROFINET device−EtherNet/IP slave(from the end of 2018)• Bus modules:−PROFIBUS−PROFINET−EtherCAT−EtherNet/IP(with Modbus/TCP)• USB interface• SD card interface• Optional display• Modern programming systemCODESYS V3 to IEC 61131-3>SP10• Integration of motion fun c tions(SoftMotion)• UL/CSA, C-Tick, IEC ExcertificationsValve terminal VTUG (port type B, V1.1)Compact with high flow rate: VTUG with plug-in.Features• A wealth of electricalconnection options from multi-pin plug up to fieldbus thanksto Festo I-Port (IO-Link)• Manifold rails for directintegration and optimisedinstallation in control cabinets• Electrically and pneumaticallyactuated valves for vacuumapplications even in an ATEXenvironment• Three valve sizes for flow ratesof 220 up to 1300 l/minInput module CTSL (port type A, V1.0)16 inputs on 8xM12 or 16xM8.Features• Display of the input statuses for each input signal via an assigned LED• Operating voltage supply 24 V DC for all connected sensors• M12: DUO plug connector with double allocation• Labelling options on all sides with large, hinged inscription label• Earthing plate and H-railmounting already integratedValve terminal VTOC (port type B, V1.0)Valve terminal CPV (port type B, V1.0)Pilot/miniature valve terminalMaximum power density, light and compact.Features• Wide range of electricalconnection options thanks to Festo I-Port (IO-Link)• Interlock option for more safetyFeatures• Electrically actuated valves for vacuum applications even in an ATEX environment • ATEX certification as per EU ATEX directive• Manifold rails for direct integration and optimised installation in control cabinets • Three valve sizes for flow ratesof 400 up to 1600 l/minProportional pressure regulator VPPM (port type A, V1.1)Position transmitter SDAT (port type A, V1.1)First proportional valve with IO-Link connection technology.Piston position detection with high repetition accuracy, whether for monitoring screwing-in processes, riveting, ultrasonic welding, pressing or adhesive bonding, or for object detection.Features• Short cycle times thanks to point-to-point connection • Choice of 3 regulator settings • Easy connection to the system • Adjustable pressure rangesApplications• Pressure regulation • Checking • Metering • Pressing • Press fittingMain industry segments • Special purpose machines, food and beverage, printing and paper, automotive, electronics and assemblyFeatures• Analogue feedback signal for piston position • Optimised for T-slots • Insertable from above• Sensing ranges from 50 to 160 mm• SDAT-MHS and SMAT-8M: transmitter solutions for large and small drives• High repetition accuracy • Programmable IO-Link/switching output• Five sensing ranges to match the most important standard strokes• Sensor function and mechanical mounting suitable for all FestodrivesSignal converters SCDN The signal converter detects analogue current or voltagesignals from sensors (transmitters). Connection to the higher-level system is provided by IO-Link. Process values can be read out and parameters changed and transmitted to additional devices.Features• Transmitter signal range scalable (e.g.: 1 … 5 V)• Measured value indicator can be individually configured • Min./max. monitoring • PNP/NPN, switchable • Eco mode• Tamper protection with security code• Filter can be adjusted to smooth the signals• Quick and easy setting of theswitching points via teach-inFlow sensor SFAW and SFAH (port type A, V1.1)Motor controller CMMO-ST (port type A, V1.1)Features• For liquid media• Clip connection for quick replacement• For measuring flow rate, volume and temperature, e.g. when monitoring a cooling circuit• Rotatable sensor display which can be aligned after installation for optimum viewing• Sensor can be rotated around its longitudinal axis when installed• Display switches between red and blue for visual feedback on system status• Sensor SFAH for air and non-corrosive gasesFeatures• Optimised Motion Series: the entire system, consisting of actuator, permanentlyintegrated stepper motor with servo functionality, servo controller and cabling, can be ordered with one order code and is easy to configure via web serverPerfect for use with:• Electric cylinder EPCO • Electric axis ELGR • Rotary driveClosed-loop servo controller as a position controller for stepper motors on IO-Link.System structure with power supply unit, motion controller CECC and laptop for simpleparameterisation via web serverPressure transmitters SPAE and pressure sensors SPAU and SPAN (port type A, V1.1)FeaturesSPAE: very small pressure sensor with indicator for core pneumatic applications• Ideal for vacuum applications with pick & place in assembly and testingSPAN: compact 30x30 mmpressure sensor with wide range of variants in pressure range up to 16 bar• Electrical compatibility with all controllers• Tamper protection• Attractive price and great performanceSPAU: universal pressure sensor and transmitter for all non-corrosive gases• Uniquely flexible connection concept• Quick and easy mounting and commissioning• Visual pressure statusindication: blue for pressure OK, red for pressure not OKSPAUSPANSPAESFAWSFAHAutomation with IO-Link ® – Subject to change – 2018/0511Vacuum generator OVEM and OVEL (port type A, V1.1)Connecting cable NEBU-… compatible with IO-Link Features• Digital setpoint/actual value transfer, convenient parame-terisation and accurate diagnostic feedback.• Device exchange withautomatic re-parameterisation.• Ejector pulse: quick, precise and reliable, separately controllable.The modular vacuum generator series OVEM offers a wide range of individually selectablefunctions, so that a solution for a huge variety of applications can be found.• OVEM monitors the setevacuation and ejection time for each cycle. With automatic and timely error reporting. Additionally: LCD displayFeatures• M8/M12 and other connecting cables available in standard lengths as stock items• Modular cable system with individually configurable connecting cables M8/M12 – precisely tailored toyour application and your requirementsSpecial catalogue “Electrical Connection Technology” available. Individual advicepossible with “cable folder”.OVELOVEM135618 e n 2018/05 – E r r o r s a n d o m i s s i o n s e x c e p t e dIO-Link – created for greater productivityDiagnostics:Festo IO-Link masters have a comprehensive range of diagnostic options – seen here using the CPX interface as an example (I-Port interface for IO-Link). The “IOL_Call” module also allows seamless integration into a Siemens diagnostic environment.Web server in PROFINET fieldbus nodeFesto Maintenance Tool FMT, error message from an IO-Link third-party deviceYour goal is to increase productivity. Automation with innovative IO-Link products from Festo takes you directly to your goal. Judge for yourself:Take your future into your own hands:with IO-Link and electric automation from FestoSecurity• IO-Link provides a secure connection for analogue, binary and serialcommunication devices.Typical IO-Link applications for complex sensor technology and terminals: in the body shop and in automotive assembly, for personal protection with safety fences, in heavy machinery construction and for machine tools, at manual workstations, assembly cells, input/output stations etc.EfficiencyIO-Link is a uniform,standardised and therefore efficient technology for installation and wiring.SimplicityIO-Link devices are quick and easy to parameterise – and can be put back into operation immediately after replacement without the need for engineering software tools.CompetencyFesto offers a comprehensive range of products for IO-Link from a single source: several masters, pressure and flowsensors, displacement encoders/position transmitters, five valve terminal series, proportionalpressure regulators, vacuumgenerators, stepper motor controllers and the connecting cables. In addition, Festo has awealth of application knowledge in factory and processautomation, as well as basic and further training for industrial users – right up to Industry 4.0.。
Eaton DE11可变速启动器180651说明书
Eaton 180651Eaton DE11 Variable speed starters, Rated operational voltage 230 V AC, 1-phase, Ie 2.3 A, 0.37 kW, 0.5 HP, Radio interference suppression filter DE11-122D3FN-N20NEspecificaciones generalesEaton DE11 Variable speed starter 1806514015081758166169 mm 230 mm 45 mm 1.04 kgIEC/EN61800-3Safety requirements: IEC/EN 61800-5-1 UL File No.: E172143 IEC/EN61800-5 CSA-C22.2 No. 14UL Category Control No.: NMMS, NMMS7 UL UL 508CUL report applies to both US and Canada CEIEC/EN 61800-3 CUL RCMSpecification for general requirements: IEC/EN 61800-2 RoHS, ISO 9001Certified by UL for use in CanadaProduct NameCatalog Number EANProduct Length/Depth Product Height Product Width Product Weight Certifications Catalog NotesModel Code240 V0.92 kVA2.3 A0.37 kW2.2 AIs the panel builder's responsibility. The specifications for the switchgear must be observed.240 V AC, 1-phase230 V AC, 1-phaseMeets the product standard's requirements.0.37 kW250 VMeets the product standard's requirements.-40 °C200 VRadio interference suppression filterPC connection0 Hz60 °C Drives - Product range catalogeaton-frequency-inverter-dimensions-009.epseaton-frequency-inverter-3d-drawing-017.epsDA-CE-ETN.DE11-122D3FN-N20NHVAC, water/wastewater and industrial mediums - brochure Number 1 in efficiency The easiest way of variable motor speed PowerXL DE1 Variable Speed StarterDA-SW-Codesys 2 SWD for DC1 and DE1DA-SW-drivesConnect - InstallationshilfeDA-SW-DE11 CANopen CODESYS2 LibraryDA-SW-DE1 ModbusRTU V1_00 LibraryDA-SW-drivesConnectDA-SW-drivesConnect - installation helpDA-SW-Codesys 3 SWD for DC1 and DE1DA-SW-USB Driver DX-COM-STICK3-KITDA-SW-DE11 CANopen ConfigFile 210DA-SW-DE11 CANopen CODESYSV3 LibraryDA-SW-USB Driver PC Cable DX-CBL-PC-1M5DA-SW-DE11 CANopen ConfigFile 203DA-SW-Driver DX-CBL-PC-3M0MN040011_ESDA-DC-00004551.pdfDA-DC-00004556.pdfIL040005ZUDA-CS-de1_fs1_ip20DA-CD-de1_fs1_ip20DX-COM-STICK3_ConnectionMains voltage - maxApparent power at 230 VRated operational current for specified heat dissipation (In) Rated operational power at 220/230 V, 50 Hz, 1-phase Assigned motor current IM at 440 - 480 V, 60 Hz, 150% overload 10.11 Short-circuit ratingRated operational voltage10.4 Clearances and creepage distancesOutput at quadratic load at rated output voltage - maxOutput voltage - max10.2.3.1 Verification of thermal stability of enclosuresAmbient storage temperature - minMains voltage - minFitted with:Output frequency - minAmbient operating temperature at 150% overload - max Starting current - max CatálogosDibujoseCAD modelFolletosGuías de Usuario Informes de certificación Instrucciones de montaje mCAD modelNotas de aplicación200 %, IH, max. starting current (High Overload), For 1.875 seconds every 600 seconds, Power section2 A60 °COP-Bus (RS485), built inModbus RTU, built inCANopen®, built in0.5 HP300 Hz240 V AC, 3-phase230 V AC, 3-phase16 kHz, 4 - 32 kHz adjustable (audible), fPWM, Power section, Main circuitParameterization: drivesConnectParameterization: drivesConnect mobile (App) Parameterization: FieldbusParameterization: KeypadOperation (with 150 % overload)-10 °C≤ 0.6 A (max. 6 A for 120 ms), Actuator for external motor brakeDoes not apply, since the entire switchgear needs to be evaluated.2.3 A Update DX-COM-STICK3How does the internal motor protection work? Starting, Stopping and OperationSet point settingConformal CoatingThe OP System Bus - Parameterizing - ControlQuick-Start-Guide DE1 (english)Fire modeMotor data Motor Protection V/f curves Slip Compensation I/O ConfigurationAccess to Parameter Level 2 Parameter Lock Load Default Quick-Start-Guide DE11 (english)Assigned motor current IM at 230 V, 50 Hz, 150% overload Ambient operating temperature - maxCommunication interfaceAssigned motor power at 115/120 V, 60 Hz, 1-phase Output frequency - maxOutput voltage (U2)Switching frequencyFeaturesHeat dissipation detailsAmbient operating temperature - minBraking currentNumber of HW-interfaces (serial TTY)10.6 Incorporation of switching devices and components Nominal output current I2NAssigned motor current IM at 220 - 240 V, 60 Hz, 150% overload 2.2 A10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.Assigned motor current IM at 115 V, 50 Hz, 150% overload2 AProduct categoryVariable speed starterRadio interference classC1: for conducted emissions onlyC2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environmentsAssigned motor current IM at 110/120 V, 60 Hz, 150% overload 2.2 AHeat dissipation capacity Pdiss0 WAssigned motor power at 460/480 V, 60 Hz, 3-phase0.5 HPNumber of HW-interfaces (RS-422)Mains current distortion120 %ProtocolOther bus systemsMODBUSEtherNet/IPCAN10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.Overvoltage categoryIIIDegree of protectionIP20NEMA OtherAmbient storage temperature - max70 °CRated impulse withstand voltage (Uimp)2000 VOutput at linear load at rated output voltage - max0.37 kWLeakage current at ground IPE - max< 10 mA (DC-operated)< 3.5 mA (AC-operated)Converter typeU converterFrame sizeFS110.2.2 Corrosion resistanceMeets the product standard's requirements.Supply frequency50/60 Hz10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.10.2.7 InscriptionsMeets the product standard's requirements.Shock resistance15 g, Mechanical, According to IEC/EN 60068-2-27, 11 msApplication in domestic and commercial area permittedYesNumber of inputs (analog)1 (parameterizable, 0 - 10 V DC, 0/4 - 20 mA)Number of phases (output)310.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.Number of HW-interfaces (RS-485)1Number of HW-interfaces (industrial ethernet)10.8 Connections for external conductorsIs the panel builder's responsibility.ProtectionFinger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)Number of relay outputs1 (parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1))Application in industrial area permittedYesClimatic proofing< 95 average relative humidity (RH), no condensation, no corrosionConnection to SmartWire-DTIn conjunction with DX-NET-SWD3 SmartWire DT moduleYesStatic heat dissipation, non-current-dependent Pvs0 W10.9.3 Impulse withstand voltageIs the panel builder's responsibility.Voltage rating - max240 VOverload current IL at 150% overload3.45 AInput current ILN at 150% overload6.2 ANumber of HW-interfaces (RS-232)Number of inputs (digital)4 (parameterizable, 10 - 30 V DC)Rated control supply voltage10 V DC (Us, max. 0.2 mA)Cable lengthC1 ≤ 5 m, Radio interference level, maximum motor cable lengthC3 ≤ 25 m, Radio interference level, maximummotor cable lengthC2 ≤ 10 m, Radio interference level, maximum motor cable length10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.Mounting positionVerticalMains switch-on frequencyMaximum of one time every 30 seconds10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.Heat dissipation per pole, current-dependent Pvid0 WElectromagnetic compatibility1st and 2nd environments (according to EN 61800-3)Resolution0.03 Hz (Frequency resolution, setpoint value)Assigned motor power at 460/480 V, 60 Hz0.5 HPRelative symmetric net voltage tolerance10 %Equipment heat dissipation, current-dependent Pvid20 WRated operational current (Ie)2.3 A at 150% overload (at an operating frequency of 16 kHz and an ambient air temperature of +50 °C)Number of outputs (analog)Suitable forBranch circuits, (UL/CSA)Apparent power at 240 V0.96 kVANumber of HW-interfaces (USB)Operating modeSpeed control with slip compensationU/f controlRated frequency - min45 HzDelay time< 10 ms, On-delay< 10 ms, Off-delayNumber of outputs (digital)Power consumption20 W10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.Number of HW-interfaces (other)Rated frequency - max66 HzVibrationResistance: According to EN 61800-5-1Short-circuit protection (external output circuits)Type 1 coordination via the power bus' feeder unit, Main circuit10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.Braking torqueAdjustable to 100 %, DC - Main circuitMax. 30 % MN, Standard - Main circuitAmbient operating temperature at 150% overload - min-10 °CRelative symmetric net frequency tolerance10 %10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.Eaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmedia2 A0.5 HP110 W at 50% current and 0% speed 10.4 W at 50% current and 90% speed 11.6 W at 50% current and 50% speed 16.8 W at 100% current and 0% speed 16.8 W at 100% current and 50% speed 18.3 W at 100% current and 90% speed 5.6 W at 25% current and 0% speed 5.6 W at 25% current and 50% speed 10 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring 0Above 1000 m with 1 % derating per 100 m Max. 2000 mAssigned motor current IM at 400 V, 50 Hz, 150% overload Number of HW-interfaces (parallel)Assigned motor power at 230/240 V, 60 Hz, 1-phase Number of phases (input)Heat dissipation at current/speed Short-circuit protection ratingNumber of interfaces (PROFINET)Altitude。
SP16系列编程器用户手册说明书
SP16 SERIES PROGRAMMERUSER MANUALRevision B5Before using the programmer, please read this manual carefully and operate the programmer correctly as required. Failure to follow the instructions will result in damage to the programmer and no warranty service!深圳硕飞科技有限公司SHENZHEN SOFI TECHNOLOGY CO.,LTD .WEB: 硕飞科技ContentsChapter1. Introduction into Products ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 3 Performance and Characters∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 3Correlation Table of SP16 Performance∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 4 Chapter 2. Programmer Hardware∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 5 Chapter 3. Quick start∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 6 Programming steps for on-line mode∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 6LED status for On-line programming mode∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 8 Chapter 4. Off-line programming∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 10 Download Off-line Data∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 10Off-line Operation - Manual Mode∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 12Off-line Operation - Automatic Control Mode∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 12ATE interface definitions∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 12LED status for off-line programming mode ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 12View Off-line Data ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 13 Chapter 5.ISP Programming∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 14 Use ISP programming mode∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 14ISP Interface∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 14ISP cable∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 14Target devices connections∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 15ISP Power supply mode∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 16 Chapter 6. FlyPRO MCP multi-machine control software∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 17 Function Introduction∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 17Usage Instruction∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 17FlyPRO_MCP function limitations∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 19About USB hub∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 19 Appendix I FAQ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙20 Appendix II Disclaimer ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 22 Appendix III Revision history ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 23Chapter 1. Introduction into ProductsPerformance and characters⚫Designed specifically for serial EEPROM / SPI FLASH device, faster and more stable than general-purpose programmer⚫USB power supply and communication, no external power supply required. Small size (size: 103x71x23mm), easy to carry⚫Supports a full range of 93/24/25/BR90 memories, supports software upgrades to increase support for new devices⚫Supports detection of 25 series SPI FLASH device models;⚫Supports pin contact detection to improve the reliability of programing;⚫Supports ISP program. On-board patch devices can be directly connected to be programmed⚫Standard 40Pin ZIF socket, applicable to wide/narrow devices and general adapters⚫Overcurrent protection function to effectively prevent misplaced or destroyed device’s effects on the programmer;⚫Programmer has a built-in 32-bit high-speed processor that provides high-speed programming and precise timing;⚫Supports off-line programming without connecting computers. Has a large data memory built-in that can supports up to 512Mbit device to program off-line (Note 1);⚫Mass production programming mode, automatic detection of device placement and start programming operation;⚫ATE interface function that supports automatic programming machine to control (Note 2);⚫Supports one computer to connect multiple programmers programming at the same time, one computer can connect up to 8 programmers⚫The buzzer present voice prompt for success or failure⚫Programmable voltage design, adjustable from 1.7V to 5.0V, supporting 1.8V/2.5V/3V/3.3V/5V devices; ⚫Provide device self-test function;⚫Support WinXP (SP2), VISTA, Win7/Win8/Win10 (32bit/64bit)Note 1: Off-line operation is limited to SP16-F, SP16-FX mode; off-line program does not support ISP mode Note 2: SP16-FX mode onlyCorrelation table of SP16 performanceModel SP16-FX SP16-F SP16-B maximum capacity of Supporteddevices512MbSupported device voltage programmable voltage adjustable from 1.7V to 5.0V , supports1.8V/2.5V/3V/3.3V/5V...Off-line programming (Note 1)Y Y N Built-in memory for off-line data 512Mb -On-line mass production (Note 1)Y (automatic detection device placement/removal) Multi connection (Note 2)YAuto serial number Y(On-line program mode only)Buzzer prompt Y (off-line mode only) N Overcurrent/short circuit protection YZIF Socket ARIESISP programming Support 24/93/25 series (clock adjustable) OTP area read and write (Note 3)supportDevice configuration (Note 3)supportAutomatic programing MachineSupport (ATE)Y N Nprograming speed (Note 4)GD25Q16(SOP8) Off-line P+V=6S; on-line P+V=7S W25Q128FV(SOP8) Off-line P+V=47S; on-line P+V=52S MX25L12845E(SOP16) Off-line P+V=62S; on-line P+V=68Soff-line data download speeds 41S@128Mb -Support the number of devices(Note 5)10284 10284Note 1: Off-line programming means the model can program without computer, suitable for mass production.On-line mass production refers to connecting to a computer for batch programming.Note 2: One computer can maximum connect eight SP16 series programmers (need to work together with FlyPRO_MCP software, search Chapter 6 for specific usage);Note 3: Depending on the software function, not all the devices are supported;Note 4: The programming speed is tested by the complete device random number, “P” is programming, V “is”verification;Note 5: Based on FlyPRO software version V4.48 (2019-05-29). The devices will increase with software upgrades. The number in the table is for reference only. Please download the latest supported software from Sofi official website download center.Chapter 2. Programmer hardwareProgrammerAccessoriesUSB Cable ISP Cable 5V/1A Power adapter⚫ The appearance of different models and batches may vary, please refer to the actualproduct;⚫ The power adapter is used to power the programmer during offline programming, andonly SP16-F/SP16-FX which supports offline programming has equipped ;⚫ The programmer is equipped with a device adapter (IC socket) as standard, pleasechoose according to your needs.USB InterfaceZIF SocketPWR(Power) STA(State) ISP/ATE InterfaceChapter 3. Quick startProgramming steps for on-line mode1. Install programmer control software: FlyPRO (Includes USB driver, single control software FlyPRO,multi-control software FlyPRO), software download website: 2. Connect programmer to USB port of computer with a USB cable.3. Run the single control software FlyPRO ,the programmer hardware will be automatically connected afterthe software starts. After the connection is successful, the software status bar will display theprogrammer mode and product serial number, and then you can program devices.The following takes a device W25Q32BV packaged of SOIC8 (208mil) as an example to introduce the steps of programming devices:4. Click the toolbar button,or menu [Device] - [Select Device], open the "Select Device" dialog box, select the device model to be programmed and the corresponding package"W25Q32BV[SOIC8]". You can quickly find the device by entering the device model keyword through the search box.Connect to computer USB portNOTE:The “W25Q32BV” in the device listdoes not have a “[ ]” suffix,indicating that the model is an DIPdevice;"[SOIC8]", "[SOIC16]", "[WSON88x6]", "[WSON8 6x5]", etc. indicatethe package type of device;“[ISP]” means to use ISP mode toprogram, please refer to “Chapter5. ISP progr amming”.5. Load programming fileClick toolbar button,or menu [File] - [Load File] to load the data file of program.6. Set operation optionsClick the toolbar button,or menu [Operation] - [Operational Options] to deviceprogramming settings. In most cases, you can use the default settings. For details on the operation options, please refer to the helper topic of the programmer software.7. Place device to ZIF SocketThe DIP packaged device can be directly inserted, and the non-straight-inserted device needs to be matched with IC socket. In this example, an SOP8 wide-body programing seat is used. First, lift ZIF Socket’s handle, insert the bottom side of IC socket into the bottom of ZIF Socket, press the handle, and then put the device into IC socket. Pay attention to the direction of the first leg of device.Pin1 Pin1Physical map Device pin position diagram For other device s’ placement (including IC socket information), please open the device information in the FlyPRO software for viewing. Most of 8-pin devices are inserted into ZIF Socket according to thecorresponding relationship on the right. A very small number of devices are placed in a special way.Please pay attention to the prompts that the software pops up.Note: ZIF Socket is only used to place the device to be programmed (including IC socket). It is forbidden to programming devices which have already been welded on circuit board, through wires from ZIF socket. The peripheral circuit on the board will cause the operation to fail. Serious conditions can cause permanent damage to the programmer hardware. The manufacturer is not responsible for anyconsequences that may result from this incorrect operation. The EMI method is recommended for the device that has been soldered. Please refer to "Chapter 5. ISP Programming".8. Perform programmingThere are three modes for programming, including manual mode, automatic mode, and automatic mass production mode. Choose one of the modes to operate according to different situations.Manual modeSelect the "Manual Operation" page in the command bar on the left side of the main software window.Follow the typical operation steps according to the device type.Automatic modeSelect the "Automatic Programming" page in the command bar on the left side of the main software window. First set the operation content, and then click the "single program" button. The programmer then performs the steps set in "Operational Content" to complete programming process of one device.Typical steps:➢Program SPI FLASH (25 series): Erase → check space →program → check➢Program SPI FLASH (25 series, brand new blank device): Program → check➢Program I2C EEPROM (24 Series): Program → Verify➢Read device data and save it to file: Read → Verify → SaveProduction modeAfter clicking “Production Programm ing” button, the programmer automatically detects the placement and removal of the device and automatically completes the steps in “Operational Content”. The software pops up a message box to remind users to pick and place devices. It is convenient and quick to program without using mouse or any buttons.LED status for on-line programming modePower LED (PWR):A long red light indicates that the power supply is normal, and a red flash indicates that the programmer has detected a device short circuit or excessive current.Status LED (STA):STA LED status Status descriptionOrange Programming deviceGreen Device programming completed, programming successfullyRed Device programming failed●The above operation is only a demonstration of the conventional programming stepsof the general device,and the specific operation needs to be determined accordingto actual needs.●For detailed instructions on using the software, please refer to the help topic ofFlyPRO software.Chapter 4. Off-line ProgramingSP16-F、SP16-FX supports off-line program. In this mode, programmers don't have to be connected to a computer. Programmer has a built-in 128Mbit data memory, eliminating the need for additional storage. Off-line program is easy and efficient. In this mode, programmers automatically detect the placement of devices, start programming, and present results via state lights and a built-in buzzer.Off-line mode includes two methods: manual operation and automatic control:In manual operation mode, programmer automatically detects placement and removal of device. Indicates working status and programming result through state lights and built-in buzzer.In automatic control mode, connecting to automatic control machine through ISP/ATE multi-function interface which controls its function and outputs corresponding indication signals.SP16-F supports off-line manual mode only; SP16-FX supports two modes above, and it can be operated by any one of them through software settings.Download off-line dataBefore off-line operation, you must download off-line data into programmer by using computer in advance. The data download operation steps are as follows:1. First connect programmer to computer with a USB cable and then turn on the FlyPRO software.2. Select the correct device model.3. Load files that need to program.4. Click the menu [Device] - [Off-line Data Management] - [Download Off-line Data] to open off-line data downloaddialog box and download off-line data. As shown below:Controlled by ISP/ATE interfaceThis option can be used only in SP16-FX. When this function is checked, SP16-FX works in the automatic control mode and works with automatic machine.If this function is not checked, SP16-FX works in manual mode.Erase optionThis feature is currently supported by SP16-F/SP16-FX and available for FLASH class devices only.In order to reduce time of erase options, it can be used to set operation mode when operation content box contains erase option.Forced Erase: Always erase the device in its entiretyNon-empty erase: Perform erase operation when the device is not blank. The programmer will first perform a blank check on the device. The erase operation will be performed only if it is not blank. If the device is already blank, the erase operation will not be performed.Device Type Operation Content setting Erase Option All blank FLASH devices program→check -All non-blank FLASH devices erase→program→check Forced eraseBlank device mixed with non-blankerase→program→check Non-empty erase deviceand it will be disabled in gray. It is enabled only if there is an erase item in the action content.For other setting options, please refer to the help topic of FlyPro software.5. Disconnect the USB cable between computer and programmer after completing off-line data download, and then programmer can work independently from the computer.Off-line operation - manual modeThe steps for the programmer to operate off-line are as follows:1. Power the programmer with the power adapter that came with the product.2. After the programmer is powered on, the internal off-line data will be checked to verify that the data iscomplete and accurate.This takes 3 to 25 seconds. STA indicator will flash green if the test passes, indicating that theprogrammer has entered to off-line programming mode. STA displays a red flashing state if the test fails, i ndicating that there is no valid off-line data in the programmer, and off-line programming cannot be started.3. The programmer's STA indicator flashes green to indicate that it is waiting for the device to be placed.4. STA stops flashing and being orange indicates that the programmer has detected the device and isprogramming.5. STA displays green or red indicates that device is programmed. Green indicates successful, and redindicates failed. At the same time, the programmer begins to wait for the current device to be removed fromZIF Socket. If the buzzer prompt function is turned on, programmer will make sounds when programming is completed.6. After detecting the device removal, programmer repeats steps 3 through 5 to program next device.Off-line operation – automatic control modeThe automatic control mode is only applicable to SP16-FX, which is used to cooperate with automatic equipment such as automatic programming machine and robot to realize automatic operation of devices. When downloading off-line data, check the "Control via ISP/ATE interface" option to enable this feature. In this mode of operation, the programmer's ATE interface provides a START enable signal, and OK / NG / BUSY indicator.ATE Interface definitionsLED status for off-line programming modeSTA LED status Status description (Manual mode) Status description(Automatic control mode, SP16-FX only)Flashing red The programmer did not downloadoff-line dataThe programmer did not download off-line dataFlashing green Waiting for device placement <no status> Orange Programming device Programming deviceGreen Device programming completed,programming successfully(Waiting for device removal)Device programming completed,programming successfullyRed Device programming failed(waiting for device removal)Device programming failed 3--BUSY 5--OK 9--NG7--START 2—VCC 4/6/8/10--GNDView off-line dataOff-line data that has been downloaded to the programmer can be viewed with FlyPRO software.Click the menu [Device] - [Off-line Data Management] - [View Off-line Data] to open off-line data viewing dialog box, as shown below:●Offline working mode does not support ISP mode to program.●Use the power adapter supplied with the product when working offline. Do not use otherpower adapters.Incorrect use of other power adapters may result in damage toprogrammer.Chapter 5. ISP ProgramingThe ISP is called In System Program, which is on-line programming. The ISP programming mode only needs to connect several signal lines to the relevant pins of the onboard device to be read and written, which can eliminate the trouble of removing and soldering devices.Use ISP programming modeThe SP16 series programmer only supports ISP mode programming of some devices. When the device model with the "[ISP]" suffix is selected in the software, it means that ISP mode is used for programming. (Selecting the device mode without ISP suffix, you can only program it through ZIF Socket. Do not select wrong mode for both programming methods.)Note: ISP program should use a dedicated ISP interface to connect, do not connect through wires from ZIF socket.ISP interfaceThe SP16 Series Programmer provides an additional ISP interface as shown below:ISP/ATE interface ISP interface definiensISP CableThe ISP cable is a 10-color color cable with a 5x2 standard plug on one end and access to the programmer's ISP/ATE interface. The other end is 10 DuPont connectors that are connected to the corresponding pins on the target board. The following figure shows the BIOS upgrade for the ASUS motherboard with SPI interface reserved.ISP/ATE接口1 97532 10864接口引脚图The correspondence between the color of the connecting line and the pin number is as follows:Color Pin number Color Pin numberbrown 1 Blue 6Red 2 purple 7 Orange(or pink) 3 Gray 8 Yellow 4 White 9Green 5 Black 10Target device connectionsCommon 25 series and 93/24 series FLASH/EEPROM connection diagrams are as follows Typical 25 series FLASH connection diagrams Typical 93 series EEPROM connection diagramsTypical 24 series EEPROM connection diagrams NOTE:Different devices will have different connection methods.For detailed connection information of the device, please open the device information in FlyPRO software for viewing.ISP Power supply modeWhen using ISP program, there are two power modes available for the target device. The power mode can be set in the operating options of FlyPRO software.⚫Powered by programmerProgrammer supplies voltage to the target board at a supply voltage of 1.8V, 2.5V, 3.3V, or 5V (set in operating options of FlyPRO software).In this mode, if the programmer detects that the target board power supply already exists, it will give an error message about the power supply conflict. Programmer has equipped with an overcurrent detection function that limits the current to 250mA when power is supplied to the target board. Overcurrentprotection will occur when current exceeding this range. If the target board's operating current is greater than 250mA, use the target board self-powered mode.⚫Target board self-poweredProgrammer does not supply power to the target board in this mode.SP16 programmer can support a target voltage range of 1.65V~5.5V. The signal driving voltage of the ISP is automatically adjusted following the VCC voltage of the target board.● ISP programming is relatively complicated to implement , you must be very familiarwith the circuit;● The interference introduced by lead wire or other circuits on the circuit board maycause ISP programming to fail. Please remove the device and use conventional ICsocket to program.● For more detailed usage, please refer to the software help topic or the electronicmanual.Chapter 6. FlyPRO MCP multi-machine control software Function Introduction●FlyPRO MCP is the multi-machine control software of SOFI SP16 series programmer●Up to 8 programmers can be connected to a single computer●Can support 8 programmers to work at the same time, including: automatic programming (single), massproduction programming, download off-line data (SP16-F/SP16-FX)●Support the management of project filesUsage InstructionStep 1: Install multi-machine applicationStarting in 2016-10-10, FlyPRO installation package includes SP16 series of multi-machine operating software (FlyPRO MCP),If it has been installed, Skip step 1.●Download FlyPRO programmer software (SP8 series/SP16 series) from SOFI official website:●Unzip the downloaded file and install itStep 2: Connect multiple SP16 programmers to the computer using a USB hubStep 3: USB driver installation●When using for the first time, the computer needs to install the driver for each USB interface programmer.Usually the computer will do this automatically.●USB driver installation may take several minutes, please wait for the installation to complete●After all the drivers of programmer are installed, restart the programmer.●If the USB hub has a power switch, re-switch the USB hub once.Step 4: Start the FlyPRO_MCP software●Click the desktop image to open the multi-machine control software.⚫After startup, you need to select the mode of programmer and enter on-line or demo mode as needed.Step 5: Create a new programming project / or open the project fileThe detailed operation steps are as follows:Step 6: ActionFlyPRO_MCP function limitationsCompared to the standard stand-alone software FlyPRO, the following functions are not supported in multi-machine software.●Automatic serial number●Manual operation (multi-machine software only supports automatic programming, mass productionprogramming and off-line data download)●Programmer device self-test●Programmer firmware upgrade●Pin contact failure prompt (multi-machine software will directly report error and terminate the operationwhen pin contact is poor)●Test device mode●View off-line information in the programmerTo apply the above information, please use the standard stand-alone software FlyPROAbout USB hub●To ensure performance, please use a USB hub with an external power supply.●It is recommended to use USB3.0 hub.Appendix I FAQ☺Why 24 series device does not have an erase function◼The device is based on EEPROM technology, device data can be directly rewritten without pre-erasing, so there is no erase operation available.◼If you want to clear the device data, please write FFH data directly to the device.☺What is the reason for the software prompt device initialization error?When programming some devices (such as 24 series devices), the programmer will perform initialization detection on the device. The error will be prompted if the detection fails. Device initialization errors usually have the following reasons:◼The device is not placed on ZIF Socket, or the device pins are not in contact.◼Device placement direction or position error◼There is a problem with the device itself◼The device mode does not match (the model selected in the software is different from the actual placement on the lock seat)◼ISP connection line problem (ISP mode only, device with [ISP] suffix)☺Why the programmed device cannot work properly?The programmed device does not work properly for the following reasons:◼The data file was not loaded correctly before the device was programmed◼There is a problem with the data file itself◼Programming operation steps are wrong◼Device working circuit / voltage problem☺Is it possible to program devices which have already been welded on circuit board through wires from ZIF socket?No.The ZIF Socket is only used to place the device to be programmed (including IC socket). It is forbidden to operate the device soldered on the circuit board through wires from ZIF socket. The peripheral circuit on the board will cause the operation to fail and result in permanent damage to the programmer hardware.Manufacturer is not responsible for any consequences that may result from this incorrect operation. The EMI method is recommended for the device that has been soldered. Please refer to "Chapter 5 ISP Program".☺Can img file be programming?The file encoding format supported by the programmer software is binary and hexadecimal (Inter HEX), the binary file is suffixed with *.bin, and the hex file is suffixed with *.hex.Img is just a file suffix, does not represent the file encoding format, usually (90% or more) such files are binary coded, can be loaded directly in the software. The software automatically recognizes whether the file is binary encoded and loads it in the recognized format.In order to ensure the accuracy of file loading, we recommend that users check the buffer checksum and file checksum with the engineering technician (or file code provider/customer, etc.) after loading such files.The information will be displayed below the main window of program software).。
托伊斯托夫 Laser 30, Laser 56 (H, I, J, K), Laser 56MH,
For Laser 30, Laser 56 (H, I, J, K), Laser 56MH, Laser 73 (K, L, M, N), Laser 73MH, OM-22, Laser60 AT, OM-23, Laser 300, Laser 530,Laser 560, Laser 730, Laser 730ATFor Laser 30, Laser 56 (H, I, J, K), Laser 56MH, Laser 73 (K, L, M, N), Laser 73MH, OM-22, Laser60 AT, OM-23, Laser 300, Laser 530,Laser 560, Laser 730, Laser 730ATUSE ONL Y TOYOSTOVE & OIL MISER GENUINE PARTS AND ACCESSORIESALL PARTS AND ACCESSORIES ARE UL/CSA/ETL LISTED.ACCESSORY/PART NO.LONG2047989861-3/4 to 78-3/4 inchesPART NUMBER Length capacity for extension installationsMEDIUM 2047989722-1/2 to 39-3/8 inchesSHORT 2047989612-5/8 to 19-5/8 inchesFor Use With:Laser Vented Heater through-the-wall installations where the heater is to be located away from the flue pipe.Contains all parts necessary for extension installations as specified in the chart below.Extension Pipe Kits For use with Standard Flue Pipe #20479891For use in wall thickness from 9 to 13 in.For use in wall thickness from 13 to 16 in.For use in wall thickness from 16 to 20 in.For use in wall thickness from 20 to 24 in.Flue Pipe Extension #20479887#20479873#20479874#20479875Standard Flue Pipe #20479891Flue Pipe Chamber #20479892LASER & OIL MISER VENTED HEATINGSYSTEMS ACCESSORIES®Gasket Service Kit For Laser 530, OM-22/23 only #20479830KIT CONTENTS:1 × Igniter gasket (#17187582) 1 × Relief gasket (#20479591) 1 × Outside nozzle gasket (#20479885)1 × Flame rod gasket (#20479511) 1 × Fuel nozzle gasket (#20479883)1 × Heat exchanger gasket (#20479893)FUEL LIFTER PUMP MODEL OPT -91UL #20477500Pumping system for use with one or more Laser and/or Oil Miser Heating Systems where gravity fed does not meet specifications. (see owner’s manual.)Automati c recovery feature after power outage.Removable Fuel Tank with Hose for Laser 55/56/560#20475922Tank capacity: 1.95 gal.NOTE: Fuel supply hose forLaser 55/56/560: #20475925Pressure Reducing Valve #10005099If the maximum height from top of the fuel tank to the bottom of the heater exceeds 8-1/2 ft., a fuel pressure reducing valve, preset at 2.5 psi, is required.Fusible Link Valve #10005597For all vented heaters ExceptLaser 300/530/560/730/730ATOil Guide #20479725For OM-22, OM-23 onlyJoint Attaching Screw Kit #20479590For Laser 30/56/560KIT CONTENTS1 × Screw 1U (#20478091)1 × Metal washer 1 × Fiber gasketSpacer #20478967For use with Standard Flue Pipe #20479891with Screw M (#20474272) × 3Overflow Tube #20474901For OPT -81UL, OPT -91UL Only needed when 2 or more lifter pumps are used in series. (See owner’s manual for details.)(3)Installation Hardware Kit#20478786 For Laser 56 (H, I, J, K),Laser 73 (K, L, M, N)Laser 560, Laser730Oil catch (#20474925) Hose band (#20474977)Intake air cap (#20474949) Bent joint (L) (#20474984)Intake pipe (#20474951) Spacer (#20478967)Wall bracket (#20474962) Exhaust air cap (#20479845)Pipe holder (#20474963) Exhaust extension pipe (S) (#20479856) Pipe stopper (#20474964) Flue pipe (#20479891)L-shaped hose (#20474975)#20479880 For OM-22, OM-23Laser 300, Laser 530Oil catch (#20474925) Hose band (#20474977)Intake air cap (#20474949) Wall bracket (2 sets) (#20479562)Pipe holder (#20474963) Pipe stopper (#20479864)Does not include the Flue Pipe (#20479891), Inlet Hose (#20474951),L-Shaped Hose (#20474975) (2 pcs.), Insulating Cloth Cover (#20474955) and Bent Joint (#20479884) for OM-22/23 and (#20479584) for LaserFUEL LIFTER PUMP/GRAVITY NOTE: Max. Lifting Height : 26 ft.FUEL LIFTER PUMP (CAN BE POSITIONED BEHIND UNIT)FUEL LIFTER PUMP LOCATION EXAMPLEFUELTANKFUEL LIFTER PUMP LOCATION EXAMPLE FUELTANKLONG, MEDIUM OR SHORTEXTENSION KIT STANDARD INSTALLATION OF FLUE PIPE3-1/23-3/83-1/2Max. 39-3/8 ~ Min. 22-7/16 inch103539-3/82-15/166-1/2 ft.19-3/411-3/4Max. 19-11/16 ~ Min. 12-5/8 inch#20474964#2047986440 inchFor specialized installations, the additional extension kit parts shown below may be purchased from a TOYOSTOVE dealer.In any installation the following limitations must NOT be exceeded:1. The total length of extension pipe between the heater and the outside tip of the flue pipe must not exceed 10 feet each for the air intake pipe and the exhaust pipe.2. Neither air intake pipe nor the exhaust pipe may have more than 3 elbows, counting the elbows at the heater. The air intake elbow supplied with the heater and the integral bends in the flue pipe are not counted as elbows.Printed in JapanRev. 07/17PART NO. B8900009*Check state and local codes for permitted uses.DISTRIBUTOR / DEALER NAME*Subject to change with or without notice.TOYOTOMI U.S.A., INC.604, Federal Road, Brookfield, CT 06804(203)775-1909DESCRIPTIONPART NAME/PART NUMBERDESCRIPTIONPART NAME/PART NUMBERL-Shaped Exhaust Joint #20479861(Connection between exhaust pipes)O-ring (ø39)(Exhaust of Flue Pipe)#20475879Exhaust Extension Pipe #20479872O-ring (ø42)(Intake of Flue Pipe)#20475880Exhaust Extension Pipe (S)#20479856(Laser 52/55/56/560 only)Pipe Stopper #20474964#20479864 (for Lser 300/530/OM-22/23 only)Adjustable Exhaust Pipe (L)#20479853Air Damper#20478366 (for Laser 56/560/73/730/60AT )#20479567 (for Laser 30)#20479866 (for Laser 300/530/OM-22/23)Adjustable Exhaust Pipe (S)#20479858L-Shaped Hose #20474975Flexible Exhaust pipe (M)#20479888Hose Band #20474977Flexible Exhaust pipe (L)#20479889Intake Pipe Joint #20474954Intake Pipe #20474951Pipe Support Hardware #20474950Insulating Cloth Cover #20474955Sleeve Cap #20474978Use with wall sleeve only (#20479867)Wall Bracket (2 sets)#20474962#20479562 (for Laser 30/300/530/OM-22/23)Oil Catch #20474925Pipe Holder #20474963Exhaust Air Cap (Metal)#20479845Bent Joint #20474984#20479584 (for Laser 30/300)#20479884 (for Laser 530/OM-22/23)Intake Air Cap (Rubber)#20474949。
老雷电子有限公司 LTS6 串行输入到分析输出传输器说明书
LAUREL ELECTRONICS, INC.LTS6 Serial-to-Analog Converter and DIN Rail TransmitterFeatures•Converts serial data to a isolated, scaled 4-20 mA or 0-10V transmitter output•Accepts an RS232 or RS485 serial data, half or full duplex, isolated•Supports Modbus RTU, Modbus ASCII, or Laurel ASCII protocols•Able to retrieve data from long character strings•Serial data rates from 300 to 9,600 baud•Analog transmitter output, isolated•Analog resolution 0.0015% of span (16 bits), accuracy ±0.02% of span•Dual solid state relays for alarm or control, isolated•Universal AC power, 85-264 Vac, or low voltage power, 10-48 Vdc or 12-32 Vac•-X extended operating temperature option for -40°C to 70°CDescriptionThe Laureate LTS6 serial input to analog output transmitteraccepts RS232 or RS485 serial data using the Modbus protocol,Laurel ASCII protocol, or direct ASCII characters, and convertsthis data to an isolated, scalable 4-20 mA, 0-20 mA or 0-10Vanalog output. The unit is housed in transmitter case which isonly 22.5 mm (0.89") thick and fits on a 35 mm DIN rail. It isnormally powered by AC (85-264 Vac), but can optionally bepowered by low voltage AC or DC. All electrical connections arevia detachable screw-clamp plugs.Features include:•Analog transmitter output, 16-bit, scalable and isolated.User selectable 4-20 mA, 0-20 mA or 0-10V levels. A 16-bitdigital-to-analog converter provides ultra-fine resolution of0.0015% and accuracy better than 0.02% of output span.Output isolation from signal, power and serial communicationgrounds is provided by a separate on-board transmitter powersupply, thereby eliminating potential problems caused byground loops. The supply can drive 20 mA into a 500Ω (orlower) load for 10V compliance, or 10V into 5 kΩ (or higher)load for 2 mA compliance.•Serial communications input, isolated. User selectableRS232 or RS485, half or full duplex, Modbus protocol, LaurelASCII protocol, or ASCII characters at data rates up to 19200bps. The RS232 interface is suitable for short cable runs andpoint-to-point communications. The RS485 interface is com-pliant with the EIA/TIA-485 standard and supports multipleaddressable devices on the same data line using the Modbusprotocol or Laurel ASCII Protocol. Modbus implementation isfully compliant with Modbus over Serial Line Specification V1.0(2002) in RTU or ASCII, half-duplex or full-duplex operation,with up to 247 digital addresses.•Ability to extract readings from long ASCII data strings.You can specify character positions, start and stop ASCIIcharacters, how many characters to skip, and how manycharacters to process. Slave operation requires connection toa master. Not applicable to the Modbus protocol.•Dual solid state relays for control or alarm. Rated 120 mAat 130 Vac or 170 Vdc, isolated.•Universal AC power supply for 85-264 Vac.•Optional low voltage power, 10-48 Vdc or 12-32 Vac.Easy Transmitter programming is via Laurel's InstrumentSetup Software, which runs on a PC under MS Windows. Thissoftware can be downloaded from Laurel’s website at no charge.The required cable from the transmitters to a PC com port isavailable from Laurel (P/N CBL04).SpecificationsSerial Communications(standard) Signal Types Data RatesOutput Isolation Serial Protocols Modbus ModesModbus Compliance Digital Addressing RS232 or RS485 (half or full duplex) 300, 600, 1200, 2400, 4800, 9600 baud250V rms working, 2.3 kV rms per 1 min test Modbus RTU, Modbus ASCII, Laurel ASCII RTU or ASCIIModbus over Serial Line Specification V1.0 (2002) 247 Modbus addresses.Up to 32 devices on an RS485 line without a repeater.Analog Output (standard) Output LevelsCompliance, 4-20 mA Compliance, 0-10V Output Resolution Output Accuracy Output Update Rate Output Isolation4-20 mA, 0-20 mA, 0-10 Vdc (selectable) 10V ( 0-500Ω load ) 2 mA ( 5 kΩ load ) 16 bits (65,536 steps) 0.02% of output spanDetermined by input data rate250V rms working, 2.3 kV rms per 1 minute test Dual Relay Output (standard) Relay Type Load Rating Two solid state relays, SPST, normally open, Form A 120 mA at 140 Vac or 180 VdcPower Input Standard Power Low Power Option Power Frequency Power IsolationPower Consumption 85-264 Vac or 90-300 Vdc 10-48 Vdc or 12-32 Vac DC or 47-63 Hz250V rms working, 2.3 kV rms per 1 min test 2W typical, 3W with max excitation outputMechanicalDimensions MountingElectrical Connections 129 x 104 x 22.5 mm case 35 mm rail per DIN EN 50022 Plug-in screw-clamp connectorsEnvironmental Operating Temperature Storage Temperature Relative Humidity Cooling Required0°C to 55°C standard, -40°C to 70°C with -X option -40°C to 85°C95% at 40°C, non-condensingMount transmitters with ventilation holes at top and bottom. Leave 6 mm (1/4") between transmitters, or force air with a fan.PinoutMechanicalOrdering GuideCreate a model a model number in this format: LTS60-X, CBL02, CBL04Transmitter Type LTS6 Serial input transmitter, 4-20 mA, 0-20 mA or 0-10V output. Power 0 85-264 Vac or 90-300 Vdc1 Isolated 12-32 Vac or 10-48 VdcOptions & Accessories-X Extended operating temperature -40°C to 70°C CBL04 RS-232 cable, LTS6 to computer or USB adapter CBL02 USB to RS-232 cable adapter。
HP 移动宽带模块技术规格(QuickSpecs)说明书
IntroductionWireless Wide Area Network (WWAN) is an optional feature sold separately or as an add-on feature on select HP notebooks, Ultrabooks and tabletsHP Mobile Broadband modules provide integrated WWAN technology such as LTE**, DC-HSPA+, HSPA+, HSDPA, HSUPA, WCDMA, GSM, GPRS, EDGE, CDMA, and GNSS connectivity over several radio frequency bands. (Select modules also supports 2G / 3G roaming). HP Mobile Broadband modules use this integrated WWAN technology to connect to wireless networks operated by mobile network operators in many countries worldwide. (Separately purchased mobile operator service required.)A WWAN connection requires wireless data service contract, network operator support, and is not available in all areas. Contact a service provider (e.g. Mobile Network Operator) to determine the coverage area and availability. Connection speeds will vary due to location, environment, network conditions, and other factors.Selected HP Mobile Broadband Wireless notebooks support Wireless WAN (WWAN) as an after-market option if ordered as a Wireless WAN (WWAN) ready configuration option. This provides customers the opportunity of adding Wireless WAN (WWAN) as an after-market option providing cost-efficient solution of adding WWAN post purchase.By offering customers this WWAN ready configuration option; HP can offer customers and integrated wireless wide area network (WWAN) option by way of after-market option kit.If the notebook is ordered with a WWAN Ready Configuration the HP production process allows for the customers to order a notebook without a HP Broadband module but receive a system that has:•WWAN antennae built into assembly•Supports aftermarket WWAN option (user accessible / upgradeable)•Subscriber identity module (SIM) user-accessibleSelect HP Mobile Broadband Wireless notebooks support Wireless Wide Area Network (WWAN) only if ordered from the factory (Select systems are not WWAN upgradeable post purchase).** 4G LTE not available on all products or in all countriesHP Mobile Broadband ModulesModelsHP XMM™ 7360 LTE-Advance WWAN 3FB01AA Key Benefits•With an HP Mobile Broadband-enabled notebook and wireless carrier service, you can check e-mail, browse the Internet, and connect to corporate networks from anywhere within your mobile operators coverage area, whether you arestationary or on the go. Enjoy the freedom of connecting in more places, the speed of broadband, the coverage of 3G or 4G networks, and the security, reliability, and ease of use of HP Business Notebooks that are Mobile Broadband enabled today!•Your HP WWAN Notebook comes preinstalled with HP Connection that enables the user to use this this generic connection manager with any SIM card from any mobile operator to set up this WWAN connection.•Convenience of having mobile wireless connectivity already set up as soon as you get your notebook, less obtrusive than a USB 3G or 4G notebook stick.•Enhance security by avoiding connections at hotels, airports, and hotspots with built-in support for VPN applications •Integrated 3G and / or 4G WWAN technology from Intel, Ericsson or Qualcomm enables high-speed Internet access via HP Mobile Broadband modules.•HP Mobile Broadband Modules allow international roaming in many countries** through support for multiple LTE /UMTS/HSPA /CDMA frequency bands and five GPRS/EDGE bands commonly used worldwide. (support varies by card, see table below)•Integrated GPS can help you accurately identify your location around the world and permit personal navigation to guide you where you need to go.***** Broadband connection requires a separately purchased wireless data service contract, mobile network service and support is not available in all areas. Contact service provider to determine the coverage area and availability. Connection speeds will vary due to location, environment, network conditions, and other factors. 4G LTE not available on all products or in all countries.*** GPS access requires an unobstructed path to multiple satellites. Performance may be affected if / when used inside of buildings, bridges or heavily congested metropolitan areas. Requires separately purchased GPS navigation software available from multiple third party GPS application vendor.CompatibilityBroadband card Compatible notebook platformHP XMM™ 7360 LTE-Advance WWAN HP ZBook 17 G5, ZBook 15 G5, ZBook 15u G5, ZBook 14u G5, ZBook x360 G5HP EliteBook 850 G5, 840 G5, 840 G5 Healthcare Edition, 840r G4, 830 G5HP EliteBook 755 G5, 745 G5, 725 G5HP ProBook 650 G4, 645 G4, 640 G4Factory-configurable options for additional select HP notebooks. Please see the QuickSpecsfor your notebook for additional compatibility information.NOTE: Works with Windows 10 onlyNOTE: Not all models are available in all regions.HP Mobile Broadband Modules and After Market Options CompatibilityProduct Part Number Product DescriptionOperator Compatibility Operating System SupportVerizon Sprint AT&T T-MobileGeneric GSM(SIM)W7supportW8.XsupportW10Support3FB01AA HP XMM™ 7360 LTE-Advance WWAN X X X * Win 8 Support only, no Win 8.1 supportService and SupportEach HP Mobile Broadband Module has a one-year limited warranty or the warranty remaining for the HP product in which it is installed. Technical support is available seven days a week, 24 hours a day, as well as in online support forums. Certain restrictions and exclusions apply.HP XMM™ 7360 LTE-Advance WWANTechnology/Operating bands LTE: 2100 (Band 1), 1900 (Band 2), 1800 (Band 3),1700/2100 (Band 4), 850 (Band 5), 2600 (Band 7), 900 (Band 8),700 (Band 12 lower), 700 (Band 13 upper), 700 (Band 17 lower),800 (Band 20), 700 (Band 28).HSPA+: 2100 (Band 1), 1900 (Band 2), 1700/2100 (Band 4),850 (Band 5), 900 (Band 8) MHzWireless protocol standards 3GPP Release 10 LTE Specification CAT.4, 20MHz BWWCDMA R99, 3GPP Release 5, 6, 7 and 8 UMTS Specification1xEVDO Release 0, A and B.E-GPRS: Class B, Multi-slot class 12, coding schemes CS1 - CS4 and MSC1 - MSC9GPS Standalone, A-GPS (MS-A, MS-B and XTRA)GPS bands 1575.42 MHz ± 1.023 MHz, GLONASS 1596-1607MHzMaximum data rates LTE: 150 Mbps (Download), 50 Mbps (Upload)DC-HSPA+: 42 Mbps (Download), 5.76 Mbps (Upload)HSPA+: 21Mbps (Download), 5.76 Mbps (Upload)CDMA 1xRTT: 153.6 kbps (Download), 153.6 kbps (Upload)EVDO Rel.A: 3.1 Mbps (Download), 1.8 Mbps (Upload)EVDO Rel.B: 14.7 Mbps (Download), 5.4Mbps (Upload)EDGE: 236.8 kbps (Download), 236.8 kbps (Upload)GPRS: 85.6 kbps(Download), 85.6 kbps (Upload)Maximum output power LTE: 23 dBmHSPA+: 23.5 dBm1xRTT/EVDO: 24dBmE-GPRS 1900/1800: 26 dBmE-GPRS 900/850: 27 dBmGPRS 1900/1800: 29.5 dBmGPRS 900/850: 32.5 dBmMaximum power consumption LTE: 1,200 mA (peak); 900 mA (average)HSPA+: 1,100 mA (peak); 800 mA (average)1xRTT/EVDO: 1,000 mA (peak); 700 mA (average)E-GPRS: 2,800 mA (peak); 500 mA (average)Form Factor M.2, 3042-S3 Key BWeight 6.2 gDimensions (LxWxD) 1.65 x 1.18 x .09 in (42 x 30 x 2.3 mm)* Mobile Broadband is an optional feature. Connection requires wireless data service contract, network support, and is not available in all areas. Contact service provider to determine the coverage area and availability. Connection speeds will vary due to location, environment, network conditions, and other factors. 4G LTE not available on all products or in all countries.Change Log© Copyright 2022 HP Development Company, L.P. The information contained herein is subject to change without notice.The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. All other trademarks are the property of their respective owners.Date of change: VersionDescription of change:History:V1 to V2 Added to be able to use the convert toolJuly 4, 2014 V20 to V21 Added three new WWAN ModulesJuly 8, 2014 V21 to V22 Changed WWAN part numbers, descriptionsMay 24, 2015 V22 to V23 Added HP lt4111b LTE/EV-DO/HSPA+ WWAN M0U02AAJune 10, 2015 V23 to V24 Added HP lt4120 LTE/EV-DO/HSPA+ WWANJuly 27, 2015 V24 to V25 Updated Removed 600 Series from HP lt4120 LTE/EV-DO/HSPA+ WWAN page 4Added Windows 10 page 5August 25, 2015 V25 to V26 Added HP lt4112 LTE/HSPA+W10 WWAN T0E33AAHP hs3110 HSPA+W10 WWAN T0E35AAHP lt4211 LTE/EV-DO/HSPA+W10 WWAN T0E34UTSeptember 3, 2015 V26 to V27 Updated HP lt4211 LTE/EV-DO/HSPA+W10 WWANFrom T0E34UT to TOE34AARemoved Removing already Discontinued productsQC431AA, WD301AA, H6F23AA, H4J87AASeptember 17, 2015 V27 to V28 Updated Updated compatibility for the HP lt4120 LTE/EV-DO/HSPA+ WWAN November 19, 2015 V28 to V29 Added Only compatible with HP EliteBook 850 G3 with HD and FHD panels. NotetoHP lt4120 LTE/EV-DO/HSPA+ WWANFebruary 29, 2016 V29 to V30 Updated Updated compatibility forHP lt4120 LTE/EV-DO/HSPA+ WWANHP hs3110 HSPA+W10 WWANHP lt4211 LTE/EV-DO/HSPA+W10 WWANDecember 16, 2016 V30 to V31 Added HP lt4132 LTE/HSPA+ 4G WWAN, 1HC91AA & HP hs3210 HSPA+ MobileModule, 1HC90AA were added their tech specs and compatibilities as well June 21, 2017 V31 to V32 Updated N8T16AA Sprint compatibility removedNovember 1, 2017 V32 to V33 Updated Added HP XMM™ 7360 LTE WWAN; removed HP HS2350 HSPA+(H4X00AA), HP hs3110 HSPA+ W8.1 WWAN (J8F05AA), HP lt4211 LTE/EV-DO/HSPA+ WWAN (J8F06AA), HP lt4112 LTE/HSPA+ W8.1 WWAN(J8F07AA), HP lt4111b LTE/EV-DO/HSPA+ WWAN (M0U02AA) November 16, 2017 V33 to V34 Update Product names updatedJanuary 24, 2019 V34 to V35 Update HP lt4132 LTE/HSPA+ 4G WWAN G2 addedJanuary 19, 2021 V35 to V36 Update All modules removed but HP XMM™ 7360 LTE-Advance WWAN。
FPGA可编程逻辑器件芯片XC5VFX70T-1FF1136I中文规格书
*Notes: 1) The recommended replacement part is not a drop in replacement. A board redesign may be necessary.
Table 2: Virtex-II Pro X Products Affected
XCN08011 (v1.2) April 27, 2010
Product Discontinuation Notice
Table 4: XC4000XL Products Affected (All Devices in this product line are affected.)
Part Number
XCN08011 (v1.2) April 27, 2010
Product Discontinuation Notice
Overview
The purpose of this notification is to communicate that Xilinx is discontinuing certain XC3000, XC4000XL, XC5206, Virtex, Spartan-3 products, and Aerospace & Defense “XQ” products.
Part Number
Replacement Part
XC2VPX20-5FF896C XC2VPX20-5FF896I XC2VPX20-5FFG896C XC2VPX20-5FFG896I
* No direct replacement * No direct replacement * No direct replacement * No direct replacement
施耐德LC1N0910M5N Easy TeSys Control 3P 接触器 数据表
Product data sheetCharacteristicsLC1N0910M5NEasy TeSys Control 3P 接触器 (1NO) - AC-3 -<= 440V 9A - 220V 线圈 50Hz主要信息产品系列Easy TeSys 产品系列Easy TeSys Control 产品类型接触器产品短名LC1N接触器应用领域应用于功率因数大于等于0.95的交流负载中应用于无感或微感负载、电阻炉使用类别AC-3 AC-3e AC-1极数3P额定工作电压 [Ue]电源回路: <= 690 V AC 50/60 Hz额定工作电流 [Ie]9 A (当运行温度 <=60 °C) 当运行电压<=<= 440 V AC AC-3对于电源回路 9 A (当运行温度 <=55 °C) 当运行电压<=<= 440 V AC AC-3e对于电源回路 25 A (当运行温度 <=60 °C) 当运行电压<=<= 440 V AC AC-1对于电源回路控制回路电压 [Uc]220 V AC 50 Hz补充信息电动机功率 (kW)2.2 KW 当运行电压<=220...230 V AC 50/60 Hz 4 KW 当运行电压<=380...400 V AC 50/60 Hz 4 KW 当运行电压<=415...440 V AC 50/60 Hz 5.5 KW 当运行电压<=500 V AC 50/60 Hz5.5 KW 当运行电压<=660...690 V AC 50/60 Hz 回路触点类型 3 NO约定发热电流 [Ith]25 A (当运行温度 <=60 °C) 对于电源回路额定接通能力 [Irms]90 A 当运行电压<=380 V AC 对于电源回路 符合 IEC 60947-4-1 140 A AC 对于辅助触点 符合 IEC 60947-5-1额定分断能力72 A 当运行电压<=440 V 对于电源回路 符合 IEC 60947额定短时耐受电流 [Icw]105 A 当运行温度<=40 °C 可持续10 s 对于电源回路 61 A 当运行温度<=40 °C 可持续60 s 对于电源回路 30 A 当运行温度<=40 °C 可持续600 s 对于电源回路与继电器配合使用的熔丝10 A gG 当运行电压<=<= 690 V 配合 1 型, 对于控制回路 符合 IEC 60947-5-1 20 A gG 当运行电压<=<= 690 V 配合 1 型, 对于电源回路平均阻抗 2.5 MΩ - Ith 25 A 50 Hz 对于电源回路每极功耗0.2 W AC-3 1.6 W AC-1额定绝缘电压 [Ui]690 V 符合 IEC 60947-4-1过电压类别III 污染等级3额定冲击耐受电压 [Uimp]6 KV 线圈未连接到电源电路 符合 IEC 60947T h e i n f o r m a t i o n p r o v i d e d i n t h i s d o c u m e n t a t i o n c o n t a i n s g e n e r a l d e s c r i p t i o n s a n d /o r t e c h n i c a l c h a r a c t e r i s t i c s o f t h e p e r f o r m a n c e o f t h e p r o d u c t s c o n t a i n e d h e r e i n .T h i s d o c u m e n t a t i o n i s n o t i n t e n d e d a s a s u b s t i t u t e f o r a n d i s n o t t o b e u s e d f o r d e t e r m i n i n g s u i t a b i l i t y o r r e l i a b i l i t y o f t h e s e p r o d u c t s f o r s p e c i f i c u s e r a p p l i c a t i o n s .I t i s t h e d u t y o f a n y s u c h u s e r o r i n t e g r a t o r t o p e r f o r m t h e a p p r o p r i a t e a n d c o m p l e t e r i s k a n a l y s i s , e v a l u a t i o n a n d t e s t i n g o f t h e p r o d u c t s w i t h r e s p e c t t o t h e r e l e v a n t s p e c i f i c a p p l i c a t i o n o r u s e t h e r e o f .N e i t h e r S c h n e i d e r E l e c t r i c I n d u s t r i e s S A S n o r a n y o f i t s a f f i l i a t e s o r s u b s i d i a r i e s s h a l l b e r e s p o n s i b l e o r l i a b l e f o r m i s u s e o f t h e i n f o r m a t i o n c o n t a i n e d h e r e i n .机械寿命10000000 次电气寿命1400000 次 AC-3150000 次 AC-1250000 次 AC-4控制回路特性AC当50 Hz控制电压限额0.85...1.1 Uc (-5…55 °C 线圈起动 50 Hz0.3...0.6 Uc (-5…55 °C 线圈释放 50 Hz(~50Hz起动)功耗 (VA)95 VA 50 Hz cos phi 0.75 (at 20 °C)(~50Hz吸持)功耗 (VA)8.5 VA 50 Hz cos phi 0.3 (at 20 °C)热消散2…3 W for 控制回路动作时间12...22 ms 闭合过程4...19 ms 打开过程最大操作频率1800 次/小时当60 °C接线能力电源回路: 螺栓紧固 1 1…4 mm² 电缆类型: 软线 带接线端子电源回路: 螺栓紧固 2 1…2.5 mm² 电缆类型: 软线 带接线端子电源回路: 螺栓紧固 1 1…4 mm² 电缆类型: 硬线 不带接线端子电源回路: 螺栓紧固 2 1…4 mm² 电缆类型: 硬线 不带接线端子控制回路: 螺栓紧固 1 1…4 mm² 电缆类型: 软线 不带接线端子控制回路: 螺栓紧固 2 1…4 mm² 电缆类型: 软线 不带接线端子控制回路: 螺栓紧固 1 1…4 mm² 电缆类型: 软线 带接线端子控制回路: 螺栓紧固 2 1…2.5 mm² 电缆类型: 软线 带接线端子控制回路: 螺栓紧固 1 1…4 mm² 电缆类型: 硬线 不带接线端子控制回路: 螺栓紧固 2 1…4 mm² 电缆类型: 硬线 不带接线端子紧固扭矩电源回路: 1.2 N.m控制回路: 1.2 N.m辅助触点类型 1 NO最小开关电压17 V 对于控制回路最小开关电流 [Imin]5 MA 对于控制回路绝缘电阻> 10 MΩ 对于控制回路不重迭时间 1.5 Ms 得电 确保NC和NO触电之间1.5 Ms 失电 确保NC和NO触电之间安装方式DIN 导轨安装底板安装环境标准IEC 60947-1EN 60947-1EN 60947-4-1GB 14048.4IEC 60947-4-1产品认证CCCIP 保护等级IP20 符合 IEC 60529防护措施TH (污染等级 3) 符合 IEC 60068周围空气温度-5…55 °C 运行-60…80 °C 存储-20…70 °C (运行在Uc下时)工作海拔3000 m 无降容耐火及耐异常高温能力850 °C 符合 IEC 60695-2-1抗冲击、震动性能抗震性能 触点打开时 (1.5 gn (5...300 Hz))抗震性能 触点闭合时 (3 gn (5...300 Hz))抗冲击性能 触点打开时 (7 gn (11ms))抗冲击性能 触点闭合时 (10 gn (11ms))高度74 Mm宽度45 Mm深度80 Mm净重0.3 Kg包装单位Unit Type of Package 1PCENumber of Units in Package 11Package 1 Height 4.78 CmPackage 1 Width7.43 CmPackage 1 Length8.35 CmPackage 1 Weight342.0 GUnit Type of Package 2S02Number of Units in Package 236Package 2 Height15.0 CmPackage 2 Width30.0 CmPackage 2 Length40.0 CmPackage 2 Weight12.5 KgUnit Type of Package 3PALNumber of Units in Package 3576Package 3 Height60.0 CmPackage 3 Width80.0 CmPackage 3 Length60.0 CmPackage 3 Weight197.042 Kg可持续性产品类型Green Premium 产品REACh法规REACh 声明REACh free of SVHC支持欧盟ROHS指令符合欧盟ROHS声明Toxic heavy metal free支持Mercury free支持RoHS exemption information支持中国 ROHS 管理办法中国 ROHS 声明环境披露产品环境文件流通资料产品使用寿命终期信息WEEE该产品必须经特定废物回收处理后弃置于欧盟市场,绝不可丢弃于垃圾桶中。
能源控制器Ⅰ型使用说明书
能源控制器Ⅰ型使用说明书青岛东软载波科技股份有限公司能源控制器类型标识代码分类说明NC X X X X-XXXX 能源控制器场景远程通信本地通信总线通信产品代号NC-能源控制器1-公变2-专变1-4G2-5G0-无1-HPLC2-微功率无线3-双模1-RS-4852-M-bus3-CAN由不大于8位的英文字母和数字组成。
英文字母可由生产企业名称拼音简称表示,数字代表产品设计序号能源控制器的功能模块类型标识代码分类见下表。
功能模块类型标识代码分类说明G X X X X-XXXX功能模块功能模块类型功能模块类型属性接口数量温度级别产品代号G-功能模块K-控制模块X-遥信模块B-本地通信模块Y-远程通信模块M-模拟量采集模块T-其他功能模块类型无补充属性,则为X;本地通信模块:Z-窄带电力线载波H-HPLCJ-微功率无线S-双模通信模块(载波&无线)M-MBUS通信模块R-RS485通信模块C-CAN通信模块T-其它信道远程通信模块:2-无线公网2G3-无线公网3G4-无线公网4G5-无线公网5GA-230MHz专网L-以太网有线网络N-公共交换电话网F-光纤有线网络T-其他信道多功能组合模块类型属性定义为:Z。
对外物理接口数量:1~9-1~9路物理接口1-C12-C23-C34-Cx由不大于8位的英文字母和数字组成,必须包含版本信息。
英文字母可由生产企业名称拼音简称表示,数字代表产品设计序号尊敬的用户:首先衷心感谢您选择青岛东软载波科技股份有限公司的产品。
青岛东软载波科技股份有限公司成立于1993年6月,2011年2月在创业板上市,现已形成以智能制造为基础,芯片设计为源头,能源互联网与智能化应用两翼齐飞的产业布局。
公司发展战略是以集成电路设计为基础,开展以融合通信为平台的技术研发;布局“芯片、软件(模组)、终端、系统、信息服务”产业链,聚焦能源互联网、智能化应用这两个战略新兴领域,打造国际一流企业。
Sanus 产品说明书.pdf_1718684224.7665863
NFC18 2 4 6 2 4 4 2 4 1 1 1 2 2
1] Remove all parts from package. Damaged or missing parts can be quickly obtained by contacting Sanus Customer Service at (800) 359-5520 or .
small objects can be hazardous to children. For this
reason rubber pads and plastic feet are provided as
b
an option. The decision to use steel spiked feet and
greatly enhance your audio video systemʼs acoustic performance and visual appeal.
Page 1
Where you locate your speakers in your listening room will greatly affect sound quality. All speakers are placement sensitive; moving them a few inches can noticeably change the sound. Take the time to find the ideal speaker locations for your room. The easiest way to find the optimum speaker locations is with educated trial and error. Your Sanus trained audio consultant can get you started in the right direction, but in the end you need to trust your ears. Happy Listening!
施耐德电气3000A 1395 直流驱动器,换装换热管组件说明书
Armature Heatpipe AssemblyReplacement(for 3000A 1395 Drives)Contents This document shows how to remove and replace an armatureheatpipe assembly in a 3000A 1395 DC drive.What This Kit Contains Using the table below, verify that you have received the appropriateitems in your kit:For this part:You should receive this quantity:armature heatpipe assembly1Other Items Needed Before you begin, be sure you also have the following:•Tools needed for:•Removing, tightening, and torquing nuts and bolts(ratchet with extension, 9/16” socket, torque wrench for25 lb-ft)•Loosening and tightening screws (slotted screwdriver)•Testing for voltage (multimeter)•Documentation:•Your drive system schematics•Publication 1395-5.40, Bulletin 1395 Digital DC Drive–User Manual•Publication 2361-5.01, Bulletin 1395 Digital DC Drive inBulletin 2361 Motor Control Center for Drive Systems–User Manual2Armature Heatpipe Assembly Replacement (for 3000A 1395 Drives)Safety PrecautionsThe following general precautions apply when working on drives:Special Instructions Important: You will need to reuse parts that are removed from thedrive. Place parts, in the order removed, on a cleansurface.Important: Some washers, such as clamp and Belleville washers, have only one correct orientation.!ATTENTION:Only those familiar with the drive system, the products used in the system, and the associated machinery should plan or implement the installation, startup, and future maintenance of the system. Failure to comply can result in personal injury and/or equipment damage.ATTENTION:Verify that all sources of AC and DC power are deenergized and locked out or tagged out in accordance with the requirements of ANSI/NFPA 70E, Part II.ATTENTION:The system may contain stored energy devices. To avoid the hazard of electrical shock, verify that all voltage on capacitors has been discharged before attempting to service, repair, or remove a drive system or its components. You should only attempt the procedures in this manual if you are qualified to do so and are familiar with solid-state control equipment and the safety procedures in publication NFPA 70E.ATTENTION:When servicing any unit, do not drop any nuts, bolts, washers, etc. inside the unit, as they may cause a short circuit on power up.ATTENTION:This drive system contains ESD (Electrostatic Discharge) sensitive parts and assemblies. Static control precautions are required when installing, testing, or repairing this assembly. Component damage can result if ESD control procedures are not followed. If you are not familiar with static control procedures, refer to Rockwell Automation publication 8000-4.5.2, Guarding Against Electrostatic Damage or any other applicable ESD protection handbook.Armature Heatpipe Assembly Replacement (for 3000A 1395 Drives)3Preliminary Steps Before replacing the armature heatpipe assembly, shut off thedrive power, wait five minutes for the voltage to discharge, openthe bridge bay door, and remove the Lexan™ shielding.Removing the Heatpipe Assembly ing a voltmeter, test the voltage across the three phases,then across the heatpipe assembly components (including theSCRs).2.Unplug the SCR leads from all the armature-pulse trans-former boards. (For SD3100 drives, tag and disconnect theSCR leads from all the pulse-gate amplifier boards.)3.Remove the armature-pulse transformer board panel byreleasing the black latches on the left and right sides of thepanel.4.Disconnect the three thermal switches and remove the wiringfrom the mounting clips.5.Remove the two bolts which connect the assembly to the out-put busbar.6.Remove the two bolts which connect the center heatpipe tothe incoming AC busbar.7.Remove the two screws from the top of the assembly wherethe Glastic™ shroud is mounted to the back plane.8.Lift the assembly out from the drive.9.With the removed heatpipe assembly, disconnect the arma-ture-pulse transformer boards from the SCR leads (not neces-sary for SD3100 drives).!ATTENTION:If there is any voltage present,remove the source of the voltage and check for voltages again before proceeding to the next step.!ATTENTION:The heatpipe assembly weighsover 70 pounds. Take appropriate measures (adhereto proper lifting procedures and/or use a liftingdevice) when removing the assembly to prevent personal injury and equipment damage.4Armature Heatpipe Assembly Replacement (for 3000A 1395 Drives)Figure 1Removing the Heatpipe AssemblyArmature Heatpipe Assembly Replacement (for 3000A 1395 Drives)5Replacing the Heatpipe Assembly 1.Ensure that the assembly is arranged for the proper polarity.Positive leg assemblies (with the large side of the SCR to theback) are to be installed on top, and negative leg assemblies(with the large side of the SCR to the front) are to be installedon the bottom.2.Attach the armature-pulse transformer board connectors tothe SCR leads. (SD3100 drives will need to have pulse-gateamplifier board connectors crimped onto the SCR leads).3.Lift the assembly into the drive and set it onto the supportpegs. Take care not to damage the assembly.4.Replace the two bolts to the top of the assembly, mountingthe Glastic to the drive.5.Connect the three thermal switch couplings and clip the wiresinto the brackets.6.Screw in the two bolts which connect the center heatpipe tothe incoming AC busbar. Torque to 25 lb-ft.7.Screw in the two bolts which connect the assembly to the out-put busbar. Torque to 25 lb-ft.8.Mount the armature-pulse transformer board panel, securingwith the black latches on the left and right sides of the panel.9.Connect all the SCR leads to the respective armature-pulsetransformer boards. (For SD3100 drives, connect all the SCRleads to the pulse-gate amplifier boards.)10.Verify that the SCRs are connected to the proper boards. Redleads connect to terminals labeled R, and white leads connect to terminals labeled W.!ATTENTION:The heatpipe assembly weighsabout 75 pounds. Take appropriate measures(adhere to your company’s procedures for materialhandling) when installing the assembly to prevent personal injury and equipment damage.6Armature Heatpipe Assembly Replacement (for 3000A 1395 Drives)Figure 2SCR to Board WiringArmature Heatpipe Assembly Replacement (for 3000A 1395 Drives)7 Concluding Steps After installing the heatpipe assembly, replace all Lexanshielding and secure the bridge bay door. Dispose of the old partsaccording to your company procedures and local codes.Lexan is a trademark of General Electric Corp.Glastic is a trademark of Glastic, Inc.Publication 2361-5.21 - July 1998P/N 185430© 1998 Rockwell International. All Rights Reserved. Printed in USA。
611U学习笔记
SIMODRIVE 611 universal_ “Speed/torque setpoint ”mod(e速度/扭矩设定点模式) :在这个模式下,模块主要用于闭环速度控制,开环扭矩控制_ ”Positioning ”mode:最大64 个定位点,各个点可以进行自由的参数定义,参数中除了点的编号,还包含有目标位置、加速度、速度、命令和使能电路在模块上具有以下接口:每个驱动具有两个模拟量接口(±10V );角度编码器接口;每个驱动有四个数字量输入和四个数字量输出;每个驱动有两个模拟量的输出;以下电机可以用在611U 驱动上:_ 1FK6, 1FT6 伺服电机,最大至140 Nm_ 1FE1 永磁同步电机_ 1PH 异步电机,最大至100 kW (1PH6, 1PH4, 1PH2, 1PH7)_ 不带编码器的异步电机_ 标准1LA 异步电机,最大至100 kW_ 1FN 直线电机X421 :信号终端,启动制约(常闭),脉冲使能(T663 )后打开,从端子663 取得反馈信号;AS1 和AS2 这个信号是电源模块所需要的,开始的时候常闭,保证电源模块上9和48端子接通,电源模块主开关吸合,提供DC600V 电源给驱动模块,当驱动模块脉冲使能后,再断开。
X431 :Terminals for supply and pulse enable (X431) 电源以及脉冲使能P24 X431.1 External power supply for digital outputs(+24 V)M24 X431.2 Reference for the external supply9 X431.3 Enable voltage(+24 V)663 X431.4 Pulse enable(+24 V)19 X431.5 Reference(Reference for all digital inputs) 如果使能信号的控制电压来自外部而不是来自9,则必须将此端子接地。
Moxa CP-114UL UL-I系列多口串行板说明书
CP-114UL Series4-port RS-232/422/485Universal PCI serial boards with optional2kV isolationFeatures and Benefits•Over700kbps data throughput for top performance•128-byte FIFO and on-chip H/W,S/W flow control•Universal PCI compatible with3.3/5V PCI and PCI-X•921.6kbps maximum baudrate for fast data transmission•Drivers provided for a broad selection of operating systems,includingWindows and Linux•Easy maintenance with built-in LEDs•Wide-temperature model available for-40to85°C environmentsCertificationsIntroductionMoxa’s CP-114UL/UL-I Series of multiport serial boards is designed to be used by industrial automation system integrators for long-distance, multipoint,PC-based data acquisition applications.On-chip Automatic Data Direction Control for precision RS-485communication requires precise timing control to enable and disable the line driver.The Moxa Turbo Serial Engine™chip that powers the CP-114UL/UL-I boards come with on-chip ADDC®,which makes RS-485as easy to use as RS-232.In RS-485mode,the serial port can connect up to31daisy-chained RS-485 devices within a range of1.2km.For long-distance RS-485communication,2kV electrical isolation protections are available to prevent equipment damage.Drivers Provided for Windows,Linux,and UNIXMoxa continues to support a wide variety of operating systems,and the CP-114UL/UL-I boards are no exception.Reliable Windows and Linux/ UNIX drivers are provided for all Moxa boards,and other operating systems,such as WEPOS,are also supported for embedded integration.SpecificationsSerial InterfaceComm.Controller MU860(16C550C compatible)Bus32-bit Universal PCIConnector DB44femaleFIFO128bytesMax.No.of Boards per PC8No.of Ports4Serial Standards RS-232,RS-422,RS-485Baudrate50bps to921.6kbpsData Bits5,6,7,8Stop Bits1,1.5,2Flow Control None,RTS/CTS,XON/XOFFParity None,Even,Odd,Space,MarkIsolation CP-114UL-I Series:2kVSerial SignalsRS-232TxD,RxD,RTS,CTS,DTR,DSR,DCD,GNDRS-422Tx+,Tx-,Rx+,Rx-,RTS+,RTS-,CTS+,CTS-,GNDRS-485-4w Tx+,Tx-,Rx+,Rx-,GNDRS-485-2w Data+,Data-,GNDSerial Software FeaturesWindows Drivers DOS,Windows95/98/ME/NT/2000,Windows XP/2003/Vista/2008/7/8/8.1/10(x86/x64),Windows2008R2/2012/2012R2(x64),Windows Embedded CE5.0/6.0,Windows XPEmbeddedLinux Drivers Linux kernel2.4.x,Linux kernel2.6.x,Linux kernel3.x,Linux kernel4.x,Linux kernel5.x UNIX Drivers QNX6,SCO OpenServer,UnixWare7,Solaris10,FreeBSDPower ParametersInput Current CP-114UL Series:320mA@5VDCCP-114UL-I Series:465mA@5VDCPhysical CharacteristicsDimensions CP-114UL Series:64.4x120mm(2.53x4.72in)CP-114UL-I Series:64.4x130mm(2.53x5.12in)LED InterfaceLED Indicators Built-in Tx,Rx LEDs for each portEnvironmental LimitsOperating Temperature Standard Models:0to55°C(32to131°F)Wide Temp.Models:-40to85°C(-40to185°F)Storage Temperature(package included)-40to85°C(-40to185°F)Ambient Relative Humidity5to95%(non-condensing)Standards and CertificationsEMC EN55032/24EMI CISPR32,FCC Part15B Class BEMS All models:IEC61000-4-2ESD:Contact:4kV;Air:8kVIEC61000-4-3RS:80MHz to1GHz:3V/mCP-114UL-I Series:IEC61000-4-4EFT:Power:1kV;Signal:0.5kVIEC61000-4-5Surge:Power:2kVIEC61000-4-6CS:150kHz to80MHz:3V/m;Signal:3V/mIEC61000-4-8International Approval CP-114UL-DB9M:KCDeclarationGreen Product RoHS,CRoHS,WEEEMTBFTime114,223hrsStandards Telcordia SR332WarrantyWarranty Period5yearsDetails See /warrantyPackage ContentsDevice1x CP-114UL Series serial boardCable1x M44to4x DB9-M cable,50cm(-DB9M models)1x M44to4x DB25-M cable,50cm(-DB25M models) Documentation1x document and software CD1x quick installation guide1x substance disclosure table1x warranty cardDimensionsCP-114UL CP-114UL-IOrdering InformationModel Name Serial Bus No.of Serial Ports Serial IsolationProtectionOperating Temp.Included CableCP-114UL w/o Cable Universal PCI4–0to55°C–CP-114UL-T Universal PCI4–-40to85°C–CP-114UL-DB9M Universal PCI4–0to55°C CBL-M44M9x4-50 CP-114UL-DB25M Universal PCI4–0to55°C CBL-M44M25x4-50 CP-114UL-I Universal PCI42kV0to55°C–CP-114UL-I-DB9M Universal PCI42kV0to55°C CBL-M44M9x4-50 CP-114UL-I-DB25M Universal PCI42kV0to55°C CBL-M44M25x4-50Accessories(sold separately)Brackets1490000001000Bracket for DB44packCablesCBL-F9M9-150DB9female to DB9male serial cable,1.5mCBL-F9M9-20DB9female to DB9male serial cable,20cmCBL-M44M9x4-50DB44male to DB9male serial cable,50cmCBL-M44M25x4-50M44to4x DB25male serial cable,50cm©Moxa Inc.All rights reserved.Updated Mar06,2020.This document and any portion thereof may not be reproduced or used in any manner whatsoever without the express written permission of Moxa Inc.Product specifications subject to change without notice.Visit our website for the most up-to-date product information.。
优光科技 Optikleuchte N 物理实验灯说明书
3B SCIENTIFIC ® PHYSICS1Bedienungsanleitung10/19 ML/ GH1 Optikleuchte 2SteckernetzgerätDie Optikleuchte entspricht den Sicherheitsbe-stimmungen für elektrische Mess-, Steuer-, Re-gel- und Laborgeräte nach DIN EN 61010 Teil 1. Er ist für den Betrieb in trockenen Räumen vor-gesehen, die für elektrische Betriebsmittel geeig-net sind.Bei bestimmungsgemäßem Gebrauch ist der si-chere Betrieb des Gerätes gewährleistet. Die Si-cherheit ist jedoch nicht garantiert, wenn das Ge-rät unsachgemäß bedient oder unachtsam be-handelt wird.Wenn anzunehmen ist, dass ein gefahrloser Be-trieb nicht mehr möglich ist (z.B. bei sichtbaren Schäden), ist das Gerät unverzüglich außer Be-trieb zu setzen.• Nicht unmittelbar in den Lichtstrahl der Optik-leuchte schauen.• Direkter Augenkontakt mit dem Lichtstrahl kann zu Blenderscheinungen führen.• Gerät nur in trockenen Räumen benutzen. • Keine Fremdspannung an die Ausgangs-buchsen legen.• Nur mit dem mitgelieferten Steckernetzgerät in Betrieb nehmen.•Optikleuchte und Steckernetzgerät nicht ab-decken und immer für gute Belüftung sorgen.3B Scientific GmbH ▪ Rudorffweg 8 ▪ 21031 Hamburg ▪ Deutschland ▪ Technische Änderungen vorbehalten © Copyright 2019 3B Scientific GmbHDie Optikleuchte ist eine neutralweiß Hochleis-tungs-LED verbaut im Kunststoffgehäuse mit Magnetfuß. Sie eignet sich um Experimente zur Strahlenoptik durchzuführen.Die Stromversorgung erfolgt über ein Stecker-netzgerät 5 V DC.Die Optikleuchte mit der Artikelnummer1022614 Optikleuchte N (115 V, 50/60 Hz) hat im Lieferumfang zusätzlich einen US-Adapter.Stromversorgung: über Steckernetzgerät5V DC, 0,35 A Buchsentyp:H ohlbuchse 5,5 mm x 2,5 mmFarbtemperatur: 4000K (neutralweiß) Umgebungstemperatur: 5 °C bis 40 °C Luftfeuchte: 80% Schutzklasse: 2 Verschmutzungsgrad: 2 Schutzart: IP20Elektromagnetische Verträglichkeit: Störaussendung: EN 55011:2009 Störfestigkeit: EN 61326-1:2013Elektrische Sicherheit: Sicherheitsbestim- mungen: DIN EN 61010-1:2010Abmessungen: ca. 70x70x51 mm Masse: ca. 150 g inkl. Stecker-NetzgerätSteckernetzgerät mit dem Netz verbinden und Optikleuchte anstecken.Hiermit ist das Gerät eingeschaltet und betriebs-bereit. Zum Ausschalten der Optikleuchte das Steckernetzgerät vom Netz trennen.Der Magnet auf der Unterseite haftet auf ver-schieden metallischen Untergründen. Unter an-derem ist die Optikleuchte gut geeignet für Expe-rimente zur Strahlenoptik mit der Optischen Bank N (4003987).∙ Optikleuchte an einem sauberen, trockenen und staubfreien Platz aufbewahren.∙ Vor der Reinigung Leuchte von der Stromver-sorgung trennen.∙ Zur Reinigung keine aggressiven Reiniger oder Lösungsmittel verwenden.∙ Zum Reinigen ein weiches, feuchtes Tuch benutzen.∙Die Verpackung ist bei den örtlichen Recyc-lingstellen zu entsorgen.∙Sofern die Leuchte selbst verschrottet wer-den soll, so gehört diese nicht in den nor-malen Hausmüll. Bei Nutzung in Privathaus-halten kann sie bei den örtlichen öffentlich-rechtlichen Entsor-gungsträgern entsorgt werden.∙Geltende Vorschriften zur Entsorgung von Elektroschrott einhalten.。
TSOP1836TE1中文资料
Document Number 82053 Rev. 3, 31-Jan-00
元器件交易网
TSOP18..TE1
Vishay Telefunken Suitable Data Format
The circuit of the TSOP18..TE1 is designed in that way that unexpected output pulses due to noise or disturbance signals are avoided. A bandpassfilter, an integrator stage and an automatic gain control are used to suppress such disturbances. The distinguishing mark between data signal ( not suppressed) and disturbance signal (supressed) are carrier frequency, burst length and Signal Gap Time (see diagram below). The data signal should fullfill the following condition: • Carrier frequency should be close to center frequency of the bandpass (e.g. 38kHz). • Burst length should be 6 cycles/burst or longer. • After each burst a gap time of at least 9 cycles is neccessary. • The data format should not make a continuous signal transmission. There must be a Signal Gap Time (longer than 15ms) at least each 90ms (see Figure A). Some examples for suitable data format are: NEC Code (repetitive pulse), NEC Code (repetitive data), Toshiba Micom Format, Sharp Code, RC5 Code, RECS–80 Code, R–2000 Code. When a disturbance signal is applied to the TSOP18..TE1 it can still receive the data signal. However the sensitivity is reduced to that level that no unexpected pulses will occure. Some examples for such disturbance signals which are suppressed by the TSOP18..TE1 are: • DC light (e.g. from tungsten bulb or sunlight), • Continuous signal at 38kHz or at any other frequency, • Signals from fluorescent lamps (see Figure B). • Continuous IR signal (e.g. 1ms burst, 2ms pause)
一胜百S136技术参数
简介STAVAX ESR(S—136)为高级不锈工具钢,其具备以下的特性:●优良的耐腐蚀性●优良的抛光性●优良的耐磨性●优良的机械加工性●淬火时具有优良的稳定性综合上列的优点,使得该钢种具有卓越的生产特性。
由于其优良的耐腐蚀性,在塑胶模具中使用的好处概述如下:●较低的维修费用模具经过长期使用后,模穴表面仍然维持原先的光滑状态。
模具在潮湿的环境下操作或存放时,不需要特别的保护。
●较低的生产成本由于模具冷却水水道不受腐蚀的影响(不象普通模具钢),热传导特性、冷却效率在模具生命期中均保持稳定,确保了模具恒久不变的成形时间。
上述的好处结合STAVAX ESR(S—136)的高耐磨性,提供低维修费和高寿命的模具,达到最佳的经济效益。
同时STAVAX ESR(S—136)经过“电渣重熔法(ESR)”精练,具备纯净而细微的组织。
化学成分碳0.38硅0.9锰0.5铬13.6钒0.3标准规范AISI 420,改良型出厂状态软性退火至约200HB 辨识颜色橙与黑用途STAVAX ESR(S—136)被推荐用于所有的模具,由于其特殊的性质,更适合特殊环境的需求。
●耐腐蚀、锈蚀对使用有腐蚀性的PVC、醋酸盐类等注模原料或必须在潮湿的环境下工作及存放的模具。
●耐磨性在使用磨耗较大的注模材料(包含热固性射出成型模)或要求模具有较长的工作时间,如电子零件、舍弃式的餐刀具、器皿等。
●高光滑度的表面生产光学产品,如照相机、太阳眼镜、化学仪器及塑胶制品等。
模具种类建议硬度,HRC注塑模1 热塑性塑胶2热固性塑胶45—5245—52 压缩往复式模具50—52 PVC,PET等等的吹气模45—52挤压、抽伸模45—52特性物理性质如表示,钢材淬火、回火至50HRC在室温及高温的数据。
温度℃20 200 400密度 kg/m37800 7750 7700弹性系数N/mm2200 000 190 000 180 000 热膨胀系数1/℃—11.2×10-6 11.6×10-6 热传导系数W/m ︒C16 20 24比热J/Kg︒C460 ——*基于热传导系数的测量实验是异常困难的,数值的最大偏差约为±15︒%室温抗拉强度抗拉强度为近似值,只供参考。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Photo Modules for PCM Remote Control Systems Available types for different carrier frequenciesTypeTSOP1130UU1TSOP1136UU1TSOP1138UU1TSOP1156UU1DescriptionThe TSOP11..UU1 – series are miniaturized receiversfor infrared remote control systems. PIN diode andpreamplifier are assembled on lead frame, the epoxypackage is designed as IR filter.The demodulated output signal can directly bedecoded by a microprocessor. The main benefit is theoperation with short burst transmission codes (e.g.RECS 80) and high data rates.UnitVmAVmA°C°C°CmW°CMax Unit 1.5mAmA 5.5VDocument Number 82012Suitable Data FormatThe circuit of the TSOP11..UU1 is designed in that way that unexpected output pulses due to noise or disturbance signals are avoided. A bandpassfilter, an integrator stage and an automatic gain control are used to suppress such disturbances.The distinguishing mark between data signal and disturbance signal are carrier frequency, burst length and duty cycle.The data signal should fullfill the following condition:•Carrier frequency should be close to center frequency of the bandpass (e.g. 38kHz).•Burst length should be 6 cycles/burst or longer.•After each burst which is between 6 cycles and 70cycles a gap time of at least 10 cycles is neccessary.•For each burst which is longer than 1.8ms a corresponding gap time is necessary at some time in the data stream. This gap time should have at least same length as the burst.•Up to 2200 short bursts per second can be received continuously.Some examples for suitable data format are:NEC Code, Toshiba Micom Format, Sharp Code, RC5Code, RC6 Code, RCMM Code, R–2000 Code,RECS–80 Code.When a disturbance signal is applied to the TSOP11..UU1 it can still receive the data signal.However the sensitivity is reduced to that level that no unexpected pulses will occure.Some examples for such disturbance signals which are suppressed by the TSOP11..UU1 are:•DC light (e.g. from tungsten bulb or sunlight)•Continuous signal at 38kHz or at any other frequency•Signals from fluorescent lamps with electronic ballast (an example of the signal modulation is in the figure below).05101520time [ms]IR Signal from Fluorescent Lamp with low Modulation2.0/m ) Figure 4. Sensitivity vs. Electric Field Disturbances1 kHzE etpi *V O V OH V OLOptical Test Signal( IR diode TSAL6200, I Output Signalt d 1 )12* t E eOptical Test Signal Document Number 8201295 11339p20.40.200.20.40.60.60.90°30°10°20°40°50°60°70°80°1.00.80.7d rel – Relative Transmission Distance Figure 13. Vertical Directivity ϕy 95 11340p20.40.200.20.40.60.60.90°30°10°20°40°50°60°70°80°1.00.80.7d rel – Relative Transmission DistanceFigure 14. Horizontal Directivity ϕxDocument Number 82012Dimensions in mm12827 Document Number 82012Ozone Depleting Substances Policy StatementIt is the policy of Vishay Semiconductor GmbH to1.Meet all present and future national and international statutory requirements.2.Regularly and continuously improve the performance of our products, processes, distribution and operating systems with respect to their impact on the health and safety of our employees and the public, as well as their impact on the environment.It is particular concern to control or eliminate releases of those substances into the atmosphere which are known as ozone depleting substances (ODSs).The Montreal Protocol (1987) and its London Amendments (1990) intend to severely restrict the use of ODSs and forbid their use within the next ten years. Various national and international initiatives are pressing for an earlier ban on these substances.Vishay Semiconductor GmbH has been able to use its policy of continuous improvements to eliminate the use of ODSs listed in the following documents.1.Annex A, B and list of transitional substances of the Montreal Protocol and the London Amendments respectively2.Class I and II ozone depleting substances in the Clean Air Act Amendments of 1990 by the Environmental Protection Agency (EPA) in the USA3.Council Decision 88/540/EEC and 91/690/EEC Annex A, B and C (transitional substances) respectively.Vishay Semiconductor GmbH can certify that our semiconductors are not manufactured with ozone depleting substances and do not contain such substances.We reserve the right to make changes to improve technical design and may do so without further notice.Parameters can vary in different applications. All operating parameters must be validated for each customer application by the customer. Should the buyer use Vishay-Telefunken products for any unintended or unauthorized application, the buyer shall indemnify Vishay-Telefunken against all claims, costs, damages, and expenses, arising out of, directly or indirectly, any claim of personal damage, injury or death associated with such unintended or unauthorized use.Vishay Semiconductor GmbH, P .O.B. 3535, D-74025 Heilbronn, Germany Telephone: 49 (0)7131 67 2831, Fax number: 49 (0)7131 67 2423。