A-0709P12AWC中文资料
彩电机芯与型号对照表分析
松下MX-4A
松下
TC-25GF88GS TC-25GF86RS TC-29GF86R TC-29GF88G
MN187265T9X
松下MX-6
松下
TC-29F99G
音飞
2199
机芯
品牌
机型
CPU型号
松下M16M
松下
TX-32V1M TX-TX-33V1X TX-33V1EE TC-32V2H TC-33V2H TC-33V2X TC-33V2PX TC-33V2L TX-29V1M TX-29V1Z TX-29V1X TX-29V1R TX-29V1EE TX-29V2H TX-29V2HA TX-29V2X TX-29V2PX TX-29V2L TX-26V2X TX-26V2HA TX-26V2X TX-26V2E TX-26T1M TX-26T1Z TX-26T1EE TX-26L1EE TX-26L1R TX-26L1RA
M37222M6-C84SP
S5S
东芝
2155DE 2155DH 2155D 2155SH 2155XC 2155XMJ
S6ES
东芝
2560XHC 2560 2960
M37222M6-D86
S6SS
东芝
2989XP
TMP87CS38N-3446
S7E
东芝
1470XNC 2170XNC
TMP87CK38N-3505
MN1874862T5B
E1W
松下
TC-47WG25G宽屏幕投影电视机
MN1876476T4N
东芝F2DB F3SS F3SSR F91DB S3ES
机芯
艾顿072907 电源保护设备说明书
Eaton 072907Eaton Moeller® series E-PKZ0 Insulated enclosure, E-PKZ0, H x W x D = 129 x 85 x 124 mm, flush-mounted, rotary handle, black/gray, IP55General specificationsEaton Moeller® series E-PKZ0 Accessory Insulated enclosure0729074015080729075124 mm 129 mm 85 mm 0.224 kgIEC/EN 60947-4-1 CSA Class No.: 3211-05 CSA-C22.2 No. 14 CECSA File No.: 165628 UL UL 508UL Category Control No.: NLRV UL File No.: E36332 CSAProduct NameCatalog Number EANProduct Length/Depth Product Height Product Width Product Weight Certifications0 AAccessoriesIs the panel builder's responsibility. The specifications for the switchgear must be observed.0 W0 WMeets the product standard's requirements.Is the panel builder's responsibility. The specifications for the switchgear must be observed.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Black-gray rotary knobPE(N) terminalNEMA 1NEMA 12IP55NEMA 3RMeets the product standard's requirements.Meets the product standard's requirements.Is the panel builder's responsibility.eaton-manual-motor-starters-mounting-e-pkz0-accessory-dimensions.eps eaton-manual-motor-starters-enclosure-e-pkz0-accessory-dimensions-002.epseaton-manual-motor-starters-enclosure-e-pkz0-accessory-dimensions-003.epseaton-manual-motor-starters-enclosure-e-pkz0-accessory-dimensions.eps eaton-manual-motor-starters-enclosure-e-pkz0-accessory-3d-drawing-003.epsDA-CE-ETN.E-PKZ0-GIL03402029ZDA-CD-e_pkz0_gDA-CS-e_pkz0_gRated operational current for specified heat dissipation (In) Product category10.11 Short-circuit ratingEquipment heat dissipation, current-dependent PvidHeat dissipation capacity Pdiss10.4 Clearances and creepage distances10.12 Electromagnetic compatibility10.2.5 Lifting10.2.3.1 Verification of thermal stability of enclosuresFitted with:Degree of protection (front side)10.2.3.2 Verification of resistance of insulating materials to normal heat10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects10.8 Connections for external conductors10.9.2 Power-frequency electric strength DibujoseCAD model Instrucciones de instalación mCAD modelIs the panel builder's responsibility.Degree of protectionIP55NEMA OtherAmbient operating temperature - max40 °C10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.10.10 Temperature riseThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.Static heat dissipation, non-current-dependent Pvs0 W10.9.3 Impulse withstand voltageIs the panel builder's responsibility.Enclosure materialPlasticAmbient operating temperature - min-25 °C10.2.2 Corrosion resistanceMeets the product standard's requirements.10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.10.2.4 Resistance to ultra-violet (UV) radiationPlease enquire10.2.7 InscriptionsMeets the product standard's requirements.10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.ModelBuilt-in10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to beEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. Todos los derechos reservados. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaevaluated.Is the panel builder's responsibility.Does not apply, since the entire switchgear needs to be evaluated.0 W10.9.4 Testing of enclosures made of insulating material 10.3 Degree of protection of assembliesHeat dissipation per pole, current-dependent Pvid。
熊猫滤清器车型对应表
机油格 燃油格 空气格 空调格 别克(轿车)2.5 3.0 备注 熊猫编号 机油格 XO-770 燃油格 XF-1611 空气格 XA-1611 空调格 XC-1611 OEM NO. PF47 GF578 A1096C 10406026 备注
机油格 燃油格 空气格 空调格 别克赛欧 熊猫编号 机油格 XO-770 燃油格 XF-1644 空气格 XA-1644 空调格 XC-1644 OEM NO. 92099013 GF618 90411732 92098459 备注
捷达王 OEM NO. 034-115-561 251-201-511A 1GD129620 191 819 640 备注
大 众 系 列
熊猫编号 机油格 XO-721 燃油格 XF-1110 空气格 XA-1122 空调格 XC-1155
OEM NO. 06A115561B 1J0201511A 1J0129620 6Q0819 638
奥迪A6L 2.4 3.0 熊猫编号 机油格 XO-801 燃油格 XF-1001 空气格 XA-1010 内空调格 XC-1010 外空调格 XC-1011 OEM NO. 06E 115 562A 4F0 201 511B 06D 115 562 4F0 819 439 4F0 819 439B
奥迪Q7 4.2 熊猫编号 机油格 XO-808 燃油格 空气格 XA-1000 空调格 XC-1000 7L0 129 620A 7H0-819-613A OEM NO. 079 198 405B 备注
奥迪A4L 2.0T 熊猫编号 机油格 XO-800 燃油格 空气格 XA-1044 空调格 XC-1088 奥迪A4L 3.2T FSI发动机 熊猫编号 机油格 XO-801 燃油格 XF-1088 空气格 XA-1080 空调格 XC-1087 OEM NO. 备注 OEM NO. 备注
Vaisala GMW90 二氧化碳和温度传感器说明书
GMW90 CO2 and Temperature Transmitter - BACnet/Modbus1234567891011Vaisala Carbocap ® CO2 and Temperature Transmitter GMW905000Price5Display and colour Standard White (RAL9003, solid cover)0Standard White (RAL9003, display cover)1Black (RAL9005, solid cover)2Black (RAL9005, display cover)3No logo, standard White (RAL9003, solid cover)8No logo, standard White (RAL9003, display cover)9Indicator cover (RAL9003, display and CO2 indicators)A6Units MetricA Non metricB 7Display configuration Default (T, CO2)A CO2CO2C8Elevation setting Standard (sea level)0Custom Define m (ft)X 9CO2 indicator levels None0Standard (800,1200 ppm)1Custom Define YellowRed ppmX 10Trimmers With adjustement trimmerA No adjustement trimmerB11Quick reference guide No manual0Multilingual for digital devices 2Accessories:TM10SP Temperature measurement module GM10SP CO2 measuremnt module219980Connection cable for HM70 hand-held meter 219690USB cable for PC connectionSelections in bold are included in the prices of the basic versions Selections in italic are available at an extra costGMW9050001A A 00A 2GMW90 CO2 and Temperature Transmitter - Current output1234567891011Vaisala Carbocap ® CO2 and Temperature TransmitterGMW904Price2Output signal 4...20mA 3-wire 40...20mA 3-wire 53Output parameter for CH1CO20...2000 ppm L CO20...5000 ppm M CO2, free scaleDefine Low High ppm N T, free scaleDefine Low High °C (°F)T 4Output parameter for CH2T -5...+55 °C (+23...+131 °F)E T 0...+60 °C (+32...+140 °F)F CO2, free scaleDefine Low High ppm N T, free scaleDefine Low High °C (°F)T 5Display and colour Standard White (RAL9003, solid cover)0Standard White (RAL9003, display cover)1Black (RAL9005, solid cover)2Black (RAL9005, display cover)3No logo, standard White (RAL9003, solid cover)8No logo, standard White (RAL9003, display cover)9Indicator cover (RAL9003, display and CO2 indicators)A6Units Metric ANon metric B7Display configuration Default (T, CO2)ACO2C8Elevation setting Standard (sea level)0Custom Define m (ft)X9CO2 indicator levels None 0Standard(800,1200 ppm)1Custom Define Yellow Red ppmX 10Trimmers With adjustement trimmer ANo adjustement trimmer B11Quick reference guide No manual0Multilingual for analog devices 1Accessories:TM10SP Temperature measurement module GM10SP CO2 measuremnt module219980Connection cable for HM70 hand-held meter 219690USB cable for PC connectionSelections in bold are included in the prices of the basic versions Selections in italic are available at an extra costGMW9044L E 1A A 00A 1GMW90 CO2 and Temperature Transmitter - Voltage output1234567891011Vaisala Carbocap ® CO2 and Temperature TransmitterGMW903Price2Output signal 0...10 V 3-wire 20...5 V 3-wire 33Output parameter for CH1CO20...2000 ppm L CO20...5000 ppm M CO2, free scaleDefine Low High ppm N T, free scaleDefine Low High °C (°F)T 4Output parameter for CH2T -5...+55 °C (+23...+131 °F)E T 0...+60 °C (+32...+140 °F)F CO2, free scaleDefine Low High ppm N T, free scaleDefine Low High °C (°F)T 5Display and colour Standard White (RAL9003, solid cover)0Standard White (RAL9003, display cover)1Black (RAL9005, solid cover)2Black (RAL9005, display cover)3No logo, standard White (RAL9003, solid cover)8No logo, standard White (RAL9003, display cover)9Indicator cover (RAL9003, display and CO2 indicators)A6Units Metric ANon metric B7Display configuration Default (T, CO2)ACO2C8Elevation setting Standard (sea level)0Custom Define m (ft)X9CO2 indicator levels None 0Standard(800,1200 ppm)1Custom Define Yellow Red ppmX 10Trimmers With adjustement trimmer ANo adjustement trimmer B11Quick reference guide No manual0Multilingual for analog devices 1Accessories:TM10SPGM10SP Temperature measurement module219980Connection cable for HM70 hand-held meter 219690USB cable for PC connectionSelections in bold are included in the prices of the basic versions Selections in italic are available at an extra costGMW9032L E 1A A 00A 1。
EAW 音箱全系列技术参数
G R O U P
性能更优越, 性能更优越,可靠性更高
EAW扬声器系统的每个部件都是度身定制的:扬声器单元、号筒 和波导管都是根据特定扬声器系统的性能要求而专门设计的;体采用 波罗的海桦木材质,人性化的设计使用更方便;经过精心设计、实现 / 完美匹配的无源分频器和/或全耦合处理器,整个系统产生平滑自然、 水晶般透明、动态宽广的一流音质。 G组扬声器系统同时秉承了EAW一贯的结实可靠、方便实用的特 点,音箱上配有把手,输入端口既方便又经久耐用,还有各类滑板、 脚轮、落地式支架等选件。为用户创造了更多的便利。
G R O U P
深圳市场:
广州“喜力”中国巡回演出使用 系列音箱 广州“喜力”中国巡回演出使用LA系列音箱 广州市第一工人文化宫榕泉影剧院使用CB2590等电影音箱 广州市第一工人文化宫榕泉影剧院使用 等电影音箱 广州平安影剧院使用CB2591、SB184C等音箱 广州平安影剧院使用 、 等音箱 广州市电影公司试片厅使用CB152等电影音箱 广州市电影公司试片厅使用 等电影音箱 广州重金属的士高使用LA、 广州重金属的士高使用 、FRz系列音箱 系列音箱 广东深圳歌舞团使用KF850、SB850 等音箱 广东深圳歌舞团使用 、 深圳福永艺术中心使用等KF850 深圳福永艺术中心使用等 广东省深圳民俗文化村中心剧场使用AS660、AS460、AS490、AS625音箱 广东省深圳民俗文化村中心剧场使用 、 、 、 音箱 深圳欢乐谷水上乐园MK5194、SB180等音箱 深圳欢乐谷水上乐园 、 等音箱 广东省南海市电力局会议中心使用了AS系列音箱 广东省南海市电力局会议中心使用了 系列音箱 珠海市石景山旅游渡假村娱乐城使用KF300、SB330等音箱 珠海市石景山旅游渡假村娱乐城使用 、 等音箱 广州花园酒店国际会议中心多媒体工程 广州天河体育馆 佛山世纪明珠体育馆 广州市一宫电影院
VAHLE CPS 无接触无线电源5A 20kHz系列产品介绍(英文)说明书
YOUR VISION – OUR SOLUTION5A | EN | Rev.032CPS® – KEY HIGHLIGHTS3 GENERAL CPS® OPERATING PRINCIPLETRANSFORMER PRINCIPLEVAHLE CPS® technology provides electrical energy without any mechan-ical contact. It utilizes the induction principle similar to a transformer‘s primary/secondary transfer. In a transformer, the primary and second-ary windings are on a common, closed ferromagnetic core. CPS® tech-nology, on the other hand, …stretches“ the primary winding to a long loop and places the secondary winding onto an open ferromagnetic core. This allows relative motion of the two windings. The transmission character-istics are optimized by using a high transmission frequency of 20 kHz.CPS®TECHNOLOGY4CPS ® – SYSTEM OVERVIEW1 PPU Primary Unit2 Track Power Litz Cable3 Guidance4 F-PU: Flat PickupPRIMARY EQUIPMENT – OVERVIEWCOMPLETE CABINET 45 KW / 11 KW• Cabinet ready for use• Technical design depending on installed system • Design according to customer specifications• Several cabinets can be interconnected for large systems with a high power requirementsMOUNTING PLATE 45 KW / 11 KW• All 20 kHz CPS ® components are pre-mounted and completely wired • Installation in an existing power switch cabinet • Supply with 400 V, three-phase alternating current • 20 kHz output for supplying the primary loopCABINET PRIMARY INVERTERAs the centerpiece of the contactless power supply, the primary inverter delivers the required electrical power for all mobile consumers located on the track. Standard three-phase alternating current of 400 V / 50 Hz (or different regional standards) is initially converted to single-phase alternating current of 20 kHz and then fed to the primary cable at a constant current of 70 A. A suitable diagnostics interface is available for displaying or moni-toring the actual operating condition.42135PRIMARY POWER UNITPPU45K – 45 KWTECHNICAL DATAELECTRICAL DATAPower (nominal/peak) ...........8.8 kW / 11 kW (PPU11K)Power (nominal/peak) ...........36 kW / 45 kW (PPU45K)Supply voltage ........................3 x 400 VACMECHANICAL DATADimension............................... 2000 x 1200 x 500 mm + 200 m socket(complete cabinet)1900 x 700 mm (mounting plate)Temperature range ................0 – 30°CProtection Type ....................... I P54 (complete cabinet)IP00 (mounting plate)Mounting plateComplete cabinet PL8x4PPU45k.2-020-072-A-IO Primary power unit 45 kW / Feed-through terminal for standard application / 20 kHz / 72 A / Stand alone / Digital IOs / Track compensation not included 10022801PPU45k.2-020-072-M-IO Primary power unit 45 kW / Feed-through terminal for standard application / 20 kHz / 72 A / Sync-Master / Digital IOs / Track compensation not included 10022821PPU45k.2-020-072-U-IO Primary power unit 45 kW / Feed-through terminal for standard application / 20 kHz / 72 A / Sync-Sub-Slave / Digital IOs / Track compensation not included 10022807PPU45k.2-020-072-S-IOPrimary power unit 45 kW / Feed-through terminal for standard application / 20 kHz / 72 A / Sync-Slave / Digital IOs / Track compensation not included10022808RANGE OF PRODUCTSDescriptionOrder No.P-SK-0220NF-0400-015-028-300-000-0-000+VTuning-Compensation for PPU15..28X220NF 0915125-9 P-SK-0150NF-0600-015-028-300-000-0-000+VTuning-Compensation for PPU15..28X150NF 0915125-8 P-SK-0100NF-0600-015-028-300-000-0-000+VTuning-Compensation for PPU15..28X100NF 0915125-7 P-SK-0068NF-0650-015-028-300-000-0-000+VTuning-Compensation for PPU15..28X68NF 0915125-6 P-SK-0047NF-0650-015-028-300-000-0-000+VTuning-Compensation for PPU15...28X47NF0915125-5TRACK COMPENSATION (MOUNTING PLATE)RANGE OF PRODUCTSDescription Order No.124 AHF50PPU11k.1-020-124-A-IO Primary power unit 11 kW / Terminal screw for standard application / 20 kHz / 124 A / Stand alone / Digital IOs / Track compensation not included10022809PPU11k.1-020-124-M-IO Primary power unit 11 kW / Terminal screw for standard application / 20 kHz / 124 A / Sync-Master / Digital IOs / Track compensation not included10022810PPU11k.1-020-124-U-IO Primary power unit 11 kW / Terminal screw for standard application / 20 kHz / 124 A / Sync-Sub-Slave / Digital IOs / Track compensation not included 10022811PPU11k.1-020-124-S-IOPrimary power unit 11 kW / Terminal screw for standard application / 20 kHz / 124 A / Sync-Slave / Digital IOs / Track compensation not included1002281272 AHF25PPU11k.1-020-072-A-IO Primary power unit 11 kW / Terminal screw for standard application / 20 kHz / 72 A / Stand alone / Digital IOs / Track compensation not included10022813PPU11k.1-020-072-M-IO Primary power unit 11 kW / Terminal screw for standard application / 20 kHz / 72 A / Sync-Master / Digital IOs / Track compensation not included100228147 PRIMARY EQUIPMENT CONFIGURATIONThe primary inverter units shown here are generally suitable for all areas of application indicated in this catalog. From a technical and economical aspect, an optimum adaptation to the respective conditions of a specific installation is assured due to an available, wide-ranging performance grading scale. Whether a complete cabinet is needed or a mounting plate – our experienced project team will always be glad to help you selecting the best suitable components.Primary equipment can be configured for installations with one segment (stand alone) or for installations with several segments.A system with two segments consists of a master unit and a slave unit. A system with more than two segments consists of a master unit, sub-slave units and a slave unit.Examples: S ystem with two segments: 1 x master and 1 x slave.System with four segments: 1 x master, 2 x sub-slave and 1 x slaveCONFIGURATION FOR 124 ACONFIGURATION FOR 72 ASystem with one segment System with several segmentsStand alone Stand alone PU22Master Sub-Slave SlavePrimary cable HF50PPU45k.1-020-124-A-IO PPU45k.3-020-124-A-IO PPU45k.1-020-124-M-IO PPU45k.1-020-124-U-IO PPU45k.1-020-124-S-IO PPU11k.1-020-124-A-IO PPU11k.1-020-124-M-IO PPU11k.1-020-124-U-IO PPU11k.1-020-124-S-IOF-Pickup E-Pickup F-Pickup F-Pickup F-PickupU-Pickup U-Pickup U-Pickup U-PickupPrimary cable PL8x4PPU45k.2-020-072-A-IO PPU45k.2-020-072-M-IO PPU45k.2-020-072-U-IO PPU45k.2-020-072-S-IOPPU11k.2-020-072-A-IO PPU11k.2-020-072-M-IO PPU11k.2-020-072-U-IO PPU11k.2-020-072-S-IO F-Pickup system F-Pickup system F-Pickup system F-Pickup system8TRACK EQUIPMENTTrack Power Compensation BoxTRACK COMPENSATION KB 10.1Dimensions (L x W x H) ............194 x 154 x 100Protection Type .......................IP65Weight .....................................1.5 kg Track current ..........................72 ATRACK COMPENSATION KB 10.4Dimensions (L x W x H) ............2x 440 x 156 x 110Protection Type .......................IP54Weight .....................................4 kg Track current ..........................124 ATRACK COMPENSATION• Compact design• Positioning near track possible • A box is required every 33 to 44 mPRIMARY CABLEPRIMARY CABLE HF 25Application ..............................EMS Diameter .................................11 mm Weight .....................................0.28 kg/m• For EMS and sortation technology applications• Special conductor made of single insulated copper braid • Small outside diameterPRIMARY CABLE HF 50Application ................ F loor skid conveyor/crane installationsDiameter .................................16.5 mm Weight .....................................0.56 kg/m• For very long track sections • Special conductor made of single insulated copper braid• Very low power loss due to large conductor cross sectionPRIMARY CABLE 8 X 4Application ................Floor skid conveyor Diameter .................................15.7 mm Weight .....................................0.49 kg/m• For standard applications • Single insulated copper conductors • Easy installation with standard cable tools10VEHICLE EQUIPMENT FOR 24 V / 27 VF-PICKUP PS08 WITH INTEGRATED REGULATORDescriptionOrder No.PS08-0027V019AD-00000000-1C103-00310+VPS08 / 0.5 kW / 20 kHz / Track conductor spacing 80 mm / integrated Regulator / 27 VDC / 19 A max / Battery Charging 0915429-3E21PS08-0600W024VD-00000000-1C102-00300+V PS08 / 0.6 kW / 20 kHz / Track conductor spacing 80 mm /integrated Regulator / 24 VDC / 25 A max0915429-1A11AL-5X2,5Cable connection between PS08 and external applicationsee page 22RANGE OF PRODUCTSBLOCK DIAGRAMDC-OUTPUTDIMENSIONS TECHNICAL DATAELECTRICAL DATAPeak power .............................0.6 / 0.5 kWNominal power .......................0.35 kWOutput voltage ........................24 / 27 VDC ±5 %Output current max ................25 / 19 ADuty cycle ................................depending on coolingTrack current ..........................72 ATrack frequency ......................20 kHzTrack conductor spacing ........80 mmPROTECTIONOutput over current ................YesMax. reverse voltage ..............30 VDCPICKUP SYSTEM MECHANICAL DATA Dimension...............................310 x 210 x 133 mmMounting holes.......................120 x 290 mm / 160 x 190 mm Weight .....................................12.8 kgNominal airgap .......................20 mmVertical tolerances .................−20 mm @ 100%, +10 mm derating Lateral tolerances ..................±15 mm @ 100%, ±30 mm derating Protection rating .....................I P20 with open plug connectionIP54 with plug connected Ambient temperature .............0 ... +30°C non-condensing Environment ...........................General industrialCooling ....................................Natural convectionVEHICLE EQUIPMENT FOR 24 V / 28.2 V / 56.2 VF-PICKUP PS27.1 WITH INTEGRATED REGULATORRANGE OF PRODUCTSBLOCK DIAGRAMDC-OUTPUTDescriptionOrder No.PS27.1-1000W024VD-00000000-1A002-0030L+VPS27.1 / 1 kW / 20 kHz / Track conductor spacing 100 mm / integrated Regulator / 24 VDC / 42 A max10011549PS27.1-28.2V036AD-00000000-1B002-0031L+VPS27.1 / 1 kW / 20 kHz / Track conductor spacing 100 mm / integrated Regulator / 28.2 VDC / 36 A max. / Battery Charging 10014177PS27.1-56.2V020AD-00000000-1B002-0031L+V PS27.1 / 1 kW / 20 kHz / Track conductor spacing 100 mm / integrated Regulator / 56.2 VDC / 20 A / Battery Charging 10014214AL-7G2,5Cable connection between PS27.1 and external applicationsee page 22DIMENSIONS TECHNICAL DATAELECTRICAL DATAPeak power .............................1 kW (10 s)Nominal power .......................0.6 kWOutput voltage ........................24 / 28.2 / 56.2 VDC ±10 %Output current max ................46.5 / 40 / 20 ADuty cycle ................................40 % Duty (10 min cycle)Track current ..........................72 ATrack frequency ......................20 kHzTrack conductor spacing ........100 mmPROTECTIONOutput over current ................YesMax. reverse voltage ..............30 VDCPICKUP SYSTEM MECHANICAL DATA Dimension...............................405 x 245 x 142 mmMounting holes.......................225 x 280 mmWeight .....................................16 kgNominal airgap .......................15 mmVertical tolerances .................−15 mm @ 100%, +20 mm derating Lateral tolerances ..................±30 mm deratingProtection rating .....................I P20 with open plug connectionIP54 with plug connected Ambient temperature .............0 ... +30°C non-condensing Environment ...........................General industrialCooling ....................................Natural convectionVEHICLE EQUIPMENT FOR 560 VF-PICKUP F330 AND REGULATOR RE330RANGE OF PRODUCTSBLOCK DIAGRAMDC-OUTPUTREADYDescriptionOrder No.vPOW_F330.1-020-124-04-L0-HV F330 / 3.3 kW / 20 kHz / 124 A / Duty 40 % / Linear 10017749vPOW_RE330.1-020-560-04-NI-ST-RC-NI Regulator / 3.3 kW / 20 kHz / 560 V / Duty 40 % /No thermal monitoring / LITE / Relay contact / No Auxiliary 10017419PX12Cable connection between F330 and RE330see page 22DIMENSIONSTECHNICAL DATAELECTRICAL DATAPeak power .............................3.3 kW Nominal power .......................1.3 kW Output voltage ........................560 VDC ±5 %Output current max ................6.5 ADuty cycle ................................40 % duty (10 min cycle)Track current ..........................124 A Track frequency ......................20 kHz Track conductor spacing ........100 mm PROTECTIONOutput over voltage ................Yes Output over current ................Yes Max. reverse voltage ..............750 VDCREGULATOR MECHANICAL DATADimension...............................190 x 120 x 87.4 mm Mounting holes.......................180.5 x 80 mm Weight .....................................1 kg Protection rating .....................IP20Ambient temperature .............0 ... +40°C non-condensing Environment ...........................General industrial Cooling ....................................Forced convectionPICKUP CONNECTION CABLELength .....................................1/2/4/6 m Outer diameter .......................11 mm Connections ............................Pre-terminated Application ..............................Flexible Min. bending radius ...............50 mmVEHICLE EQUIPMENT FOR 48 VU-PICKUP PK31 AND REGULATOR RE080DescriptionOrder No.PK31 -0900W110VA-VLPK1000-19I00-8000K+VPK31 / 900 W / 20 kHz / Nominal power 400 W / 1 m connecting cable 10020600RE080.1-20-048-03-UC-LI-NI-NI Regulator / 0.8 kW / 20 kHz / Duty 30 % / 48 V / Thermal monitoring / LITE / Relay contact / No Auxiliary10021229AL-3G4Cable connection between RE080 and external applicationsee page 22RANGE OF PRODUCTSBLOCK DIAGRAMDC-OUTPUT 1DC-OUTPUT 2USBDIMENSIONS TECHNICAL DATAELECTRICAL DATAPeak power .............................0.8 kW (5 s)Nominal power .......................0.26 kWOutput voltage ........................48 VDC ±5 %Output current max ................18 ADuty cycle ................................30 % (10 min cycle)Track current ..........................72 ATrack frequency ......................20 kHzTrack conductor spacing ........67 mmPROTECTIONOutput over voltage ................YesOutput over current ................YesOver temperature ...................YesREGULATOR MECHANICAL DATA Dimension...............................304 x 220 x 94.5 mm Mounting holes.......................204 x 175 mmWeight .....................................3.7 kgProtection rating .....................I P20 with open plug connectionIP54 with plug connected Ambient temperature .............5 ... +40°C non-condensing Environment ...........................General industrialCooling ....................................Natural convectionPICKUP CONNECTION CABLELength .....................................1 mOuter diameter .......................11.2 mmConnections ............................Pre-terminatedApplication ..............................FlexibleMin. bending radius ...............40 mmPICKUP MECHANICAL DATA Dimension...............................114 x 75 x 89.4 mm Mounting holes.......................86 x 47 mmWeight .....................................1.6 kgNominal airgap .......................12.5 mmVertical tolerances .................±3 mmLateral tolerances ..................+4 / −12.5mm @ 100%VEHICLE EQUIPMENT FOR 560 VE-PICKUP PUE4 AND REGULATOR RE55RANGE OF PRODUCTSBLOCK DIAGRAMDC-OUTPUTTEMPERATURE WARNINGDescriptionOrder No.PUE4-4000W270VA-00000000-12E00-00E00+VPUE4 / 4 kW / 20 kHz / Nominal power 3.2 kW / 200 mm connecting cable 10005185RE55.1-5500W560VD-000W00VD-11014-0030X+V RE55.1 / 5.5 kW / 20 kHz / 560 VDC 10016225VL-7G2,5Cable connections between PUE4 and RE55see page 22DIMENSIONS TECHNICAL DATAELECTRICAL DATAPeak power .............................4 kW (5 s)Nominal power .......................1.3 kWOutput voltage ........................560 VDC ±10 %Output current max ................8 ADuty cycle ................................30 % (10 min cycle)Track current ..........................72 ATrack frequency ......................20 kHzTrack conductor spacing ........84 mmPROTECTIONOutput over current ................YesMax. reverse voltage ..............800 VDCREGULATOR MECHANICAL DATA Dimension...............................282 x 247 x 169 mm Mounting holes.......................215 x 214 mmWeight .....................................7.2 kgProtection rating .....................I P20 with open plug connectionIP54 with plug connected Ambient temperature .............5 ... +40°C non-condensing Environment ...........................General industrialCooling ....................................Natural convectionPICKUP CONNECTION CABLELength .....................................0.2/1/2/3/4.5 mVEHICLE EQUIPMENT FOR 288 V / 560 VE-PICKUP PU22 AND REGULATOR RE22RANGE OF PRODUCTSBLOCK DIAGRAMDC-OUTPUT 1DC-OUTPUT 2DescriptionOrder No.PU22-022KW310VA-00000000-00000-00C00+VPU22 / 22 kW / 20 kHz / Mounting on narrow side 0915007-120PU22-022KW310VA-00000000-00000-00D00+VPU22 / 22 kW / 20 kHz / Mounting on long side0915007-220RE22-040KW288VD-1K6W24VD-25A11-13400+VRE22 / 40 kW / 20 kHz / 2 x PU22 / 288 VDC / Auxilliary / 1.6 kW / 24 VDC 0915011-0218RE22-040KW560VD-960W24VD-25A00-00400+V RE22 / 40 kW / 20 kHz / 2 x PU22 / 560 VDC / Auxilliary / 0.19 kW / 24 VDC 0915011-0200AL-5G16Cable connections between PU22 and RE22see page 2221DIMENSIONSTECHNICAL DATAELECTRICAL DATAPeak power .............................22 / 40 kW * (10 s)Nominal power .......................10 / 25 kW *Output voltage ........................288 / 560 VDC ±10 %Output current max ................155 / 80 A Track current ..........................124 A Track frequency ......................20 kHz Track conductor spacing ........133 mmPROTECTIONOutput over voltage ................Yes Output over current ................YesREGULATOR ELECTRONIC MECHANICAL DATADimension...............................328 x 660 x 290 mm Mounting holes.......................200 x 630 mm Weight .....................................31.5 kg Protection rating .....................IP20Ambient temperature .............0 ... +30°C non-condensing Environment ...........................General industrial Cooling ....................................Forced convectionVariant PU22 xxx-120Power CablesPAUL VAHLE GmbH & Co. KGWesticker Str. 5259174 Kamen Germany Phone: +49 2307 704-0*************VAHLE Incorporated 407 Cane Island Pkwy Katy, TX, 77494, USA Phone: +1 713-465-9796 ******************connect with us! @vahleincW 1103931/00/e n | 0 | R e v .03 | 03/20 | E r r o r s a n d t e c h n i c a l m o d i f i c a t i o n s s u b j e c t t o c h a n g e .。
PA79中文资料
Full temperature range, f ≥ 60Hz
Full temperature range, f < 60ure range
TEMPERATURE RANGE, case
OFFSET CURRENT, initial
12
400
INPUT RESISTANCE, DC
106
INPUT CAPACITANCE
R COMMON MODE VOLTAGE RANGE, pos.
COMMON MODE VOLTAGE RANGE, neg.
3'4
7
$$ 3$
74 $$ */ $3
*-*. 1" #
$3 $$ */
$$
74
3$
3/ $/
7
The typical application diagram shows a bridge connection of the two amplifiers inside a dual PA79 and provides output voltage swing twice that of one amplifier. Two possible situations where there is an advantage would be in applications with low supply voltages, or applications that operate amplifiers near their maximum voltage ratings in which a single amplifier could not provide sufficient drive. The bridge connection also effectively doubles the slew rate, and non-linearity becomes symmetrical reducing second harmonic distortion in comparison to a single amplifier circuit.
Agilent 8890 5977C Series gas chromatograph mass s
Agilent 5977C GC/MSD SystemThe Agilent 8890/5977C Series gas chromatograph/mass selective detector (GC/MSD) builds on a tradition of leadership in GC and MS technology, with the world’s most competitive performance and productivity features.Agilent GC/MSD system featuresAgilent 5977C GC/MSD — the most sensitive and robust MSD provides:–Four EI source options including the revolutionary high-efficiency source (HES), which offers the industry’s lowest instrument detection limit (IDL) and bestcarrier gas applications.signal-to-noise ratio (S/N) and a HydroInert source for H2– A heated monolithic quartz gold quadrupole (heatable up to 200 °C) for rapid elimination of contamination to keep the analyzer clean.– A second-generation triple-axis detector (TAD) for eliminating neutral noise.–Scan speeds up to 20,000 u/sec (extractor ion source and HES).–An optional oil-free IDP-3 roughing pump: a cleaner, quieter, and greener alternative (for use with turbo molecular pump systems).10-Year value promiseSupport is guaranteed for 10 years from the date of purchase, or Agilent will provide credit for the residual value of the system toward a model upgrade.Installation checkout specifications Agilent verifies GC/MSD system performance at the customer site.IDL is a statistically based metricthat more accurately confirms system performance than an S/N measurement. Test specificationsare based on splitless injection intoan Agilent J&W HP-5ms Ultra Inert30 m × 0.25 mm, 0.25 μm column for helium and a 20 m × 0.18 mm, 0.18 μm column for HydroInert with hydrogen. IDL analyses use lab helium (hydrogen for HydroInert) with GC gas filters installed. See more about the IDL test at /Library/ technicaloverviews/Public/5990-8341EN.pdf* IDL was statistically derived at 99% confidence level from the area precision of eight sequential splitless injections of OFN (octafluoronaphthalene). Demonstration of IDL specifications require a compatible system configuration, including a liquid autosampler with a 5 μL syringe.–HES IDL was measured using 10 fg injection, 1 µL injection.–Other IDLs were measured using 100 fg, 1 µL injection.–A 30 m column was used for helium IDL checkout; a 20 m column was used for hydrogenIDL checkout.–Helium carrier gas for Installation Specifications of the HES, Extractor, and Stainless steel sources; hydrogen carrier gas for Installation Specification of the HydroInert source only.–Reference IDL specifications from the above table will be confirmed only when purchased as an additional service with a compatible new system (GC and MS) installation.Signal-to-noise (S/N) specificationsa S/N checkout is performed only if there is no compatible autosampler (which is required for IDL checkout). Helium carrier gas, manual injection using a 30 m × 0.25 mm,0.25 µm column and in scan mode. Hydrogen carrier gas, manual injection using 20 m × 0.18 mm, 0.18 µm column and in scan mode. When the autosampler (ALS) is present, these specifications are a reference of the performance. Reference S/N specifications from the above table will not be confirmed at installation or introduction for ALS equipped systems.b Standard scanning from 50 to 300 u at nominal 272.0 u ion.c 1 μL injection of 100 pg/μL benzophenone (BZP) standard, 80 to 230 u scan at nominal 183 u ion, using methane reagent gas.d 2 μL injection of 100 fg/μL OFN standard scanning from 50 to 300 u at nominal 272 u ion, using methane reagent gas.2a Only applicable with optional Accurate Mass software package. Scan mode only. Not verified during installation.b As scan rate increases, sensitivity will decrease, and resolution may degrade.c A high flow rate into a fixed ion source will cause a loss in sensitivity.d The heated quadrupole mass filter should not require maintenance, but if maintenance is required, it should be performed by an Agilent service engineer.34aInlet temperature should be cool enough to touch when performing maintenance.bA micro ion gauge is shipped standard for the CI system, and is available optionally for EI systems.DE67854286This information is subject to change without notice.© Agilent Technologies, Inc. 2022Printed in the USA, May 26, 20225994-4846EN。
上汽大众-全新一代朗逸-使用维护说明书-中文
本说明书适用于下列表中各种型号的上汽大众 All New Lavida 全新一代朗逸系列轿车。
用户在使用本公司产品以前,必须认真研读产品使用维护说明书,任何不当的使用、保养和修理都可能导致车辆的损坏及影响质量担保服务。
因此,在使用产品前请认真阅读本使用维护说明书,并对照表中的型号确认您的车型。
名称型号发动机变速箱全新一代朗逸SVW71221AN DJN七挡自动变速器全新一代朗逸SVW71421AL CSS七挡自动变速器全新一代朗逸SVW71521AG DLW五挡手动变速器全新一代朗逸SVW71521BG DLW六挡自动变速器全新一代朗逸SVW71221CN DJN七挡自动变速器全新一代朗逸SVW71421CL CSS七挡自动变速器全新一代朗逸SVW71521EG DLW五挡手动变速器全新一代朗逸SVW71421BT DJS七挡自动变速器全新一代朗逸SVW71421DT DJS七挡自动变速器全新一代朗逸SVW71221BN DLS七挡自动变速器全新一代朗逸SVW71221DN DLS七挡自动变速器全新一代朗逸SVW71521CF DMB五挡手动变速器全新一代朗逸SVW71521GF DMB五挡手动变速器全新一代朗逸SVW71521DF DMB六挡自动变速器全新一代朗逸SVW71221EN DLS七挡自动变速器全新一代朗逸SVW71421ET DJS七挡自动变速器本使用维护说明书描述了该车型车辆在当前范围的配置、功能及操作的一般通用信息,但用户车辆的实际配置和功能等信息以具体交付时的为准。
本公司将持续对各种车型进行改进,各车型在外形、配置、功能和结构设计等方面也可能随时会发生变化,故本公司有权在法律法规允许的范围内对本说明书有关版本进行更改、补充,若用户对此有疑义请及时拨打上汽大众客户服务热线400-820-1111予以咨询。
未经本公司书面同意,不得复制、翻译或摘录本使用维护说明书。
上汽大众汽车有限公司依法保留对本说明书有关版本进行更改、补充等的一切权利。
Dell Precision 5570 规格表说明书
见证奇迹的地方起始重量为 1.84 kg/4.06 lbs通过 ISV 认证先进的散热技术(图片仅供参考,不是 5570)用户可选择散热表 (USTT)双对向输出 (DOO)风扇,带液晶聚合物叶片双进气孔散热绝缘材料,GORE™Dell Optimizer for Precision我们让它更智能。
您让它更好用戴尔智能调优软件为世界上超级智能提供支持,从而彻底改变您的工作方式。
它是一款基于人工智能的优化软件,可针对您的工作方式进行学习和响应,旨在通过后台运行** 自动提高应用程序性能、电池续航时间、音频设置效果和隐私保护,而丝毫不妨碍您的工作。
专为混合工作打造的个性化性能为创作人员提供强大支撑Dell Optimizer for Precision 凭借增强的音频效果产品1234戴尔 UltraSharp 34 系列曲面 USB-CHUB 显示器— U3421WE戴尔高级多设备无线键盘及鼠标—KM7321W戴尔 Thunderbolt 4 坞站— WD22TB4戴尔 Premier 主动式降噪无线耳机—WL7022戴尔移动适配器扬声器— MH3021P 戴尔 Pro 混合单肩提包双肩背包 15 寸— PO1521HB 34" WQHD 曲面显示器具有宽广的色彩覆盖率和包括 RJ45、USB-C 及便于使用的前置端口在内的多种连接方式,为您带来沉浸式工作体验。
这款高端全尺寸键盘和精致鼠标套装具有可编程快捷键以及长达 36 个月的电池续航时间,让您跨 3 台设备无缝进行多任务处理。
采用未来就绪型模块化设计的 Thunderbolt 4坞站,大幅提升您 PC 的性能。
这款无线耳机通过了 T eams 认证,配有主动降噪功能和智能传感器,可自动将您的通话静音和取消静音,让您随时随地轻松协作。
采用集成式扬声器的多端口适配器,可提供一体化的连接和会议解决方案。
它采用戴尔的 EcoLoop™ 纺液着色工艺制作而成,与传统印染工艺相比,可将废水排放减少 90%,二氧化碳排放量减少 62%,能耗降低 29%。
EA9系列样本资料
施耐德电气在中国
1987年,施耐德电气在天津成立第一家合资工厂梅兰日兰,将断路器技术带到中国,取代传统保险 丝,使得中国用户用电安全性大为增强,并为断路器标准的建立作出了卓越的贡献。90年代初,施耐 德电气旗下品牌奇胜率先将开关面板带入中国,结束了中国使用灯绳开关的时代。
创维新型号彩电机型与机芯对照表[1] 2
创维新型号彩电机型与机芯对照表(高清部分)机型机芯25T86HD 6D92,6P1625T86HT 6D90(HS32),6D91(HS32),6D9225T88HT 6D90(HS32),6D91,6D91(HS32),6D9228T88HT 6D96,6D96(HS33),6D96(V12),6D96(旧遥控),6D96(遥控更换),6D96(遥控兼容)29T60HT 6D78,6D78(V12)29T61HT 6D90(HS32),6D91(HS32),6D9229T65HT 6D96(V12),6D96(频率合成)29T66HT 6D90(HS32),6D91(HS32),6D92,6D92(新遥控),6D9629T68HT 6D75,6D92,6D92(不带无线耳机),6D96,6D96(HS33),6D96(遥控兼容)29T81HT 6D90(HS32),6D91,6D91(HS32),6D92 29T83HT 6D75,6T1829T84HT 6D78,6D78(V12),6D90(HS32),6D91 29T86HM 6D9729T86HT 6D96,6D96(HS33),6D96(旧遥控兼容),6D96(频率合成),6D97(HS33 new),6M23,6T18,8A08,8A0929T88HT 6D77,6D78,6D78(V12),6D7929TPHD 6D92,6M2129TPHT 6D92,6M2329TWHT 6T18,6T18(new)31T88HT 6P18(new)32FWHT 6M2332T88HT 6M23,6M23(V12)33T88HT 6D96(HS33)34SIHT 6D96,6D96(旧遥控),6D96(旧遥控兼容)34T60HT 6D78,6D78(V12)34T66HT 6D75,6D76,6D78,6D78(V12),6D78(new)34T68HT 6D78,6D92,6D92(新遥控),6D96,6D96(HS33),6D96(旧遥控兼容)34T81HM 6D97(HS33),6D97(HS33 new)34T81HT 6D96,6D96(HS33)34T83HT 6D7834T86HT 6D96,6M23,6M23(V12)34T88HD 6M2334T88HM 6D7934T88HT 6D78,6D78(V12),6D78(带3.1声道),6D78(带侧A V),6M23,6M23(new)34TIHT 6D96,6D96(HS33)34TPHT 6D96(HS33),6M2336T88HT 6M23,6M23(V12)创维电视机型机芯对照表(普通部分)机型机芯14NS9000 3P3021D68AA 3S3521N61AA 3P30,3P30(新编号),3P30(新遥控)21N66AA 3T30,3T30(HS29),3T30(HS29新软件),3T36,3T36(HS29),3T36(HS29新软件)21ND9000 3P3021ND9000A 3P32,3P35,3P30(中英俄)21NF8800 3S3021NF8800A 3S30(外销),3S30(新遥控),3Y30 21NF9000 3S30,3S31,3S35,3T36,3Y3021NI9000 3P30,3P30(新遥控)21NK9000 3P30(新遥控)21NK9000A 3P3021NS9000 3P30(新遥控),3T30,3T30(新软件),3T36,3T36(HS29新软件),3T36(新软件防雷)21T66AA 3T30,3T30(HS29),3T30(HS29新软件),3T36,3T36(HS29),3T36(HS29新软件)21T68AA 3S30,3T23,3T30,3T30(HS29新软件),3T36,3T36(HS33新软件),3Y30(外购遥控)21T81AA 3Y3021T88AA 3S30,3S30(新遥控),3T30(HS29新软件)21TB9000 3T30,3T30(HS29),3T30(HS29新软件)21TH9000 3P3021TI9000 3T30(HS29),3T36(HS29),3T36(HS29新软件)21TM9000 3P32,3T30(HS29),3T30(HS29新软件),3T36(HS29),3T36(HS29新软件)21TR9000 3T30,3T30(HS29新软件),3T36(HS29),3T36(HS29新软件)25N61AA 4P36,5P3025N66AA 4T30,4T30(HS29),4T36(HS29无音效),4T36(HS29新软件),5S30,5T36(HS29)25ND9000 5S35,4P36,4T36(HS29新软件)25NF8800A 5S31,5Y3025NF9000 5S30,5S31,5S35,5Y3025NI9000 4T30(HS29),5T35(HS29新软件),5T36(HS29),5T36(HS33)25NM9000 4T36(新软件无音效)25NP9000 4P30,5P3025NX9000 4P36,4T36(HS29新软件),5S31,5Y3025T61AA 4P3625T62AA 5Y3025T66AA 4T30,4T30(HS29),4T36(HS29新软件),5T36(HS29),5T36(HS29新软件)25T68AA 4T36(HS29),4T36(HS29新软件),4T36(HS33新软件),5S31,5T35(HS29新软件)25T81AA 5S3125T83AA 5S3125T85AA 5S3125T85AC 4T3625T88AA 5S3125T95AC 4T3625TI9000 4T30(HS29),5T35(HS29新软件),5T36(HS29)25TM9000 4T30(HS29),4T30(新软件),4T36,4T36(HS29新软件),4T36(HS29新软件无音效),4T36(HS29新软件无音效绿色电视),5S35,5T36(HS29)29T60AA 5P30,5P3629T61AA 5P3029T62AA 5Y30,5P3029T63AA 5P30,5P36,5Y3029T66AA 5T30,5T30(HS29),5T36(HS29),5T36(HS29伴音功放)29T68AA 5T30,5T30(HS29),5T30(HS29新软件),5T36(HS29),5T36(HS33加遥控器)29T83AA 5T3629TB9000 5Y3029TH9000 5Y3029TI9000 5P3629TIMK 6P1829TK9000 5N2029TM9000 4P36,4P36(HS29新软件),5P30,5T28,5T30,5T36,5T36(HS29)29TW9000 5P3029TX9000 5P30,5Y3129YP9000 5L30,5P3034SG9000 5P3034T60AA 5T30,5T30(HS29)34T66AA 5T30,5T30(HS29),5T36(HS29)34T68AA 5T30,5T30(HS29),5T36,5T36(HS29新软件)创维电视机型机芯对照表(液晶部分)机型机芯7LAAAW 8TS2TFT-15K2 8T05TFT-15S 8T0315AAB 8TT1,8TT1(BUE屏),8TT1(LG屏),8TT1(三星屏)15AAC 8TM1,8TT1,new15AAXMX 8TM115LABXT 8TT615LEATX 8TT615LAIX 8TG317LDAW 8TT3,8TT3(V12)17LDATW 8TT317LEATW 8TT617LFAPT 8TG520AAA 8TM1,8TT1,8TG520LCATS 8TP120LEATX 8TT620LFAPV 8TG522LEATV 8TG326LCAIW 8TT3,8TT3(V12)26LCATW 8TT3,8TT3(V12)30AAAHW 8TG2,8TP230LABTW 8TP2,8TP2(V12)30LBATW 8TP2,8TP2(V12)30LCATW 8TP232LCAIW 8TT3,8TG3,8TG3(V12),8TP2 32LCATW 8TP2,8TP2(V12)37LBAIW 8TT3,8TT3(V12)40LBAIW 8TT3(V12)创维机芯型号查找A系列机心机心 CPU 集成电路IC4A01 CTV222S PRC1 TDA8222 TA86594A01 M34300 N4 TDA8222 TA86595A01 CTV222S PRC TDA2549 TDA2461 TA86594A PCA84C 440P5K01 MN15287K TA8611 TDA3857 准分离伴音处理TA8759 5P01 CTV322S TDA8361S系列机心3S28 ST6388BE STV22463S30 HD0401HOUDAJ7907A STV22474S01 ST63156 STV8223 STV21165S01 ST6388 STV8223 STV21164S ST63T87 TDA8224 TDA8219 TDA8214A5S28 ST63T88B1 STV22465S30 HD0401HOUDAJ7907A STV2247D系列机心6D91 LA76931N 超级芯片6D92 LA76930N 超级芯片6P16 M37281 LA7655创维T系列机芯所用集成电路查询机芯集成电路型号3T01/4T01机芯解码:TB1238; CPU: TMP87CK38N-3658 3T20机芯解码:TB1238; CPU: TMP87CK38N-1N863T21机芯解码:TB1238;CPU:87CM38N3T30机芯 21TB9000;CPU与解码为:TMP8803\TMP88233T30机芯 21TM9000;CPU与解码为:TMP88033T30机芯一路AV;CPU与解码为:TMP88013T30/3T36机芯二路AV;CPU与解码为:TMP88033T30/3T36机芯一路AV;CPU与解码为:TMP88233T30/3T36机芯二路AV;CPU与解码为:TMP88233T36机芯 CPU与解码为:TMP8803\TMP88234T20机芯解码:TB1238; CPU: TMP87CK38N-1N864T30机芯 CPU与解码为:TMP8809;3路AV4T30/5T36机芯 CPU与解码为:TMP8809;2路AV4T30机芯 CPU与解码为:TMP8807/TMP88274T30/5T36机芯 CPU与解码为:TMP8829新软件;3路AV4T36机芯 CPU与解码为:TMP8803;2路AV4T36机芯 CPU与解码为:TMP8823;2路AV5T03机芯 CTV-2981;解码:TB1238; CPU: TMP87CK38N-36585T20机芯 25Nl9000;解码:TB1240; CPU: TMP87CK38N-1R025T21机芯解码:TB1240; CPU:TMP87CS38N-3ED9(早期);CPU:TMP87CS38N-3G82(后期) 5T25机芯解码:TB1240; CPU: TMP87CK38N-3G825T28机芯 29SP9000;解码:TB1240; CPU: TMP87CK38N-4FP15T30机芯 25NI9000;CPU与解码为:TMP8809\TMP88295T35机芯 CPU与解码为:TMP8823;二路AV5T36机芯 CPU与解码为:TMP8809\TMP8829创维D系列机芯所用集成电路查询机芯集成电路型号5D01机芯 100Hz机型:2981-100;CPU:C87C766BRD;解码:TDA9143;5D20机芯 CPU:ST92196A/B;解码:DPTV-66305D25机芯 CPU:ST92196A/B;解码:DPTV-66305D25机芯 34英寸;CPU:ST92196A/B;解码:DPTV-66305D26机芯 29TIDP;CPU:ST92196A/B;解码:DPTV5D26机芯 34TPDP;CPU:ST92196A/B;解码:DPTV5D28机芯 34TIDP;CPU:ST92196A/B;解码:DPTV5D30机芯 CPU:M37280/M37281;5D60机芯机型:29TBDA;CPU:MSP8849;解码:DPTV5D66机芯机型:29TBDP;CPU:MSP8849;解码:DPTV5D70机芯 CPU:M37274;解码:VPC3230;变频:NV3205D76机芯 CPU:M37274;解码:DPTV5D78机芯 34TPDP;CPU:M37274;解码:DPTV5D90机芯解码:VPC32156D72机芯机型:29T68HD;CPU:M37274/M37281;解码:VPC3230;变频:PW1235 6D76机芯机型:34T66HD;CPU:M37274/M37281;解码:DPTV6D78机芯 CPU:M372816D92机芯解码:LA76930;2004-05-26版本,行频:33.75K6D92机芯 29英寸北京松下管;解码:LA76930;2004-05-26版本,行频:35K6D92机芯 25英寸;解码:LA76930;2004-08-02版本;6路AV,行频:35K6D92机芯 25英寸;解码:LA76930;2004-08-02版本;4路AV,行频:35K6D95机芯 29英寸;解码:DVP004;CPU:S88496D95机芯 34英寸;解码:DVP004;CPU:S88496D96机芯 29英寸;解码:SVPV12;CPU:S8849创维I系列机芯所用集成电路查询机芯集成电路型号5I01机芯双频机;CPU:CCZ3005;解码:VPC32155I30机芯解码与CPU为:VCT3803创维M系列机芯所用集成电路查询机芯集成电路型号5M10机芯双频机;CPU:M37274;解码:VPC3210A6M20机芯 29寸高清彩电系列;CPU:DS88C(P)4504;解码:DPTV-3D6M20机芯 34寸高清彩电系列;CPU:DS88C(P)4504;解码:DPTV-3D6M23机芯 34寸高清彩电系列:配松下管6M23机芯 34寸高清彩电系列:配东芝管6M23机芯 34寸高清彩电系列:配三星管创维P系列彩电机芯所用集成电路型号查询机芯集成电路型号3P10/4P10机芯解码:OM8838;CPU:MTV8803P20/4P20机芯解码:OM8838;CPU:KS88C83163P21机芯解码:OM8838PS;CPU:4749-Z00010-42\4749-Z00011-423P30机芯 CPU与解码为:TDA9370PS-N23P30机芯 CPU与解码为:TDA9370PS|N2|AI08433P30机芯 CPU与解码为:TDA9370PS|N23P30机芯 CPU与解码为:OM8370PS4P30机芯 CPU与解码为:TDA9370PS-N2;四路AV输入4P30机芯 CPU与解码为:TDA9370PS;二路AV输入4P30机芯 CPU与解码为:TDA9370PS;一路AV输入4P36机芯 29寸华飞管;CPU与解码为:TDA9370;一路AV输入5P03机芯 CPU:47-Z00001-42到47-Z00007-42都为此机芯CPU,其中Z0003与Z0006为带丽音功能,可互换,另外其它的可互换。
摩克斯A7130-MP海洋电脑说明书
MC-7130-MP Marine ComputerThe MC-7130-MP marine computer is powered by the latest 3rd generation Intel® Core™ i3 3120ME processor. Optimized for ECDIS, these computers can serve in nearly any bridge role thanks to their comprehensive range of I/O and communications interfaces: eight NMEA 0183 terminals, four serial ports, four gigabit Ethernet ports, six USB 2.0 and three SuperSpeed USB 3.0 ports. The MC-7130-MP is designed to give unrivalled PC performance for a new level of flexibility and control for marine applications.Designed with the highest quality and durability in mind, the marine- grade MC-7130-MP computer features a rugged chassis and vibration tolerance up to 1G, together providing a highly reliable platform that can easily tolerate the harsh environmental challenges of marine environments. Additionally, the MC-7130-MP’s compact size and low power consumption return a low heat profile that increases MTBF while simplifying integration into existing bridge systems or newly designed marine solutions.Finally, the MC-7130-MP also offers convenient connectivity expansions via a single PCIe (x16) slot and two universal PCI slots, allowing users to install a variety of peripheral extensions for radar, PROFIBUS, VGA graphics, and more, allowing for direct consolidation of all input sources at a single hub.The MC-7130-MP platform is optimized for use with the Windows XP Embedded, XP Professional, or Windows 7 operating systems, allowing users to choose the development environment most suitable for the application’s needs.Appearance OverviewFront ViewRemovableRear ViewSpecificationsComputer CPU: Intel ®Core ™i3-3120ME (BGA CPU package), dual core threaded64 bit 2.4 GHz processorOS: Windows 7, Windows XP SP3, Windows XP Embedded (must be installed by the user)System Chipset: Intel ® QM77 Express ChipsetSystem Memory: 16 GB capacity, 4 GB pre-installed: 2 slots of 8 GB DDR3-1066 204 pin SO-DIMM SDRAMUSB: USB 2.0 host x 6, USB 3.0 host x 2, Type A connectorsStorageStorage Support:• 2 SATA 6 Gb/s ports for SSD/HDD • 2 SATA 3 Gb/s ports for SSD/HDDOther PeripheralsAudio: Line in x 1, Line out x 1, Mic in x 1KB/MS: 2 PS/2 interfaces supporting standard PS/2 keyboard and mousePCI Slots: 2LPT Port: 1PCIe x16 Slots: 1DisplayDisplay Interface:• VGA Interface x 1: 15-pin D-Sub connector (female), with resolution up to 1920 x 1080• DVI-D Interface x 2: 29-pin DVI-D connectors (female), with resolution up to 1920 x 1080, 60Hz (with reduced blanking)Graphics Controller: Onboard Intel ®HD 4000 graphics(type A) (RJ45) Output1 x PCIe (x16)Ordering InformationInitial Insulation Resistance: 1000 M Ω(min.) @500 VDCMechanical Endurance: 100,000 operations @2A, 30 VDC resistive loadElectrical Endurance: 100,000,000 operations Contact Resistance: Max. 50 M Ω @6 V, 0.1AConnector Type: 2 Euroblock 8-pin 3.81 mm screw terminals Isolation: Relay isolation; ESD protection to DNV specificationsLEDsSystem: Storage, PowerLAN: 2 LEDs on each port: 100 Mbps (left) / 1000 Mbps (right)Physical CharacteristicsHousing: Aluminum, sheet metal Weight: 8 kgDimensions: 322 x 300 x 150 mm (12.68 x 11.81 x 5.91 in)Mounting: WallSystem Cooling: Moxa intelligent fanEnvironmental LimitsOperating Temperature: -15 to 55°C (5 to 131°F)Storage Temperature: -20 to 60°C (-4 to 131°F)Ambient Relative Humidity: 5 to 95% (non-condensing)Anti-Vibration:•***********(ClassA),sinewave,2-100Hz,1Oct./min.,1.5hr per axis• 1 G rms @ DNV 2.4, random wave, 3-100 Hz, 2.5 hr per axis•***********(ClassC),sinewave,2-50Hz,1Oct./min.,1.5hr per axisPower RequirementsInput Voltage:• DC: 24 VDC (with tolerance from 18 to 30 VDC, 2-pin terminal block) • AC: 100 to 240 VACPower Consumption: Less than 100 W, 2.5 A @ 24 VDCStandards and CertificationsSafety: UL 60950-1, DNV 2.4, IEC 60945 (4th), IACS E10EMC: EN 55022 Class B, EN 55024-4-2, EN 55024-4-3, EN 55024-4-4, FCC Part 15 Subpart B Class B Marine: IEC 60945 4th, IACS E10Green Product: RoHS, cRoHS, WEEEReliabilityMTBF (mean time between failures):• Telcordia (Bellcore) Standard TR/SR: 269,934 hrs • MIL-HDBK-217 FN2: 114,305 hrsWarrantyWarranty Period: 3 yearsDetails: See /warrantyAvailable ModelsMC-7130-MP: x86-based ECDIS computer with 3rd gen. Intel® Core™ i3 CPU processor, 4 serial ports, 8 NMEA 0183 ports, 4 Gigabit Ethernet ports, 8 DIs, 8 DOs, 6 USB 2.0 ports, 2 USB 3.0 ports, 2 PCI slots, 1 PCIe x16 slot, VGA/DVI, TPM, and AC/DC power inputsOptional Accessories (can be purchased separately, for AC power input)PWC-C13US-3B-183: Power cord with 3-pin connector, USA plug PWC-C13EU-3B-183: Power cord with 3-pin connector, Euro plug PWC-C13UK-3B-183: Power cord with 3-pin connector, British plug PWC-C13AU-3B-183: Power cord with 3-pin connector, Australia plug PWC-C13CN-3B-183: Power cord with 3-pin connector, China plug Package Checklist• 1 MC-7130-MP computer• 2 removable storage protection keys• 8 screws for internal and removable drive trays • Wall mounting kit• 6 screws for wall mounting • 1 terminal block for power input • 4 terminal blocks for DI/DO channels • 8 terminal blocks for NMEA 0183 ports • Documentation and driver CD • Quick installation guide (printed)•Warranty cardEthernet Interface LAN: 4 auto-sensing 10/100/1000 Mbps ports (RJ45)Magnetic Isolation Protection: 1.5 kV built inSerial InterfaceSerial Standards:• 2 RS-232/422/485 ports, software-selectable (DB9 male) • 2 RS-232 ports (DB9)• 8 NMEA 0183 terminals (NMEA 2000 available on request)Serial Communication ParametersData Bits: 5, 6, 7, 8Stop Bits: 1, 1.5, 2Parity: None, Even, Odd, Space, MarkFlow Control: RTS/CTS, XON/XOFF, ADDC® (automatic data direction control) for RS-485Baudrate: 50 bps to 230.4 KbpsSerial SignalsRS-232: TxD, RxD, DTR, DSR, RTS, CTS, DCD, GND RS-422: TxD+, TxD-, RxD+, RxD-, GND RS-485-4w: TxD+, TxD-, RxD+, RxD-, GND RS-485-2w: Data+, Data-, GNDNMEA InterfaceSerial Standards:NMEA 0183v2 (NMEA 2000 available on request)Base Serial Standard: • NMEA 0183: RS-422• NMEA 2000: CAN bus (Available on request)Optical Isolation Protection: 3 kV Voltage Differential: -15 V to +15 V Baudrate: 4800 bps Data Bits: 8Stop Bits: 1, 1.5, 2Parity: NoneHandshake: NoneDigital InputInput Channels: 8 dry channels, with 4 grounds Digital Input Levels for Dry Contacts: • Logic level 0: Close to GND • Logic level 1: OpenConnector Type: 6-pin Phoenix-compatible 3.81 mm screw terminal block, x 2Isolation: ESD protection to DNV specificationsRelay OutputType: Form A (N.O.) power relay Output Channels: 8 output channelsContact Rating: 2A, 30 VDC / 0.5 A, 125 VAC under resistor load。
Agilent 11970系列混合器数据手册说明书
Agilent 11970 Series Harmonic MixersData Sheet For use with the Agilent E4407B, 8560E/EC Series, 8566B,71000 Series, and PSA Series spectrum analyzers,plus the N9030A PXA signal analyzerExceptional performanceThe Agilent Technologies 11970 Series harmonic mixers are general purpose mixers employing a dual-diode design to achieve very flat frequency response and lowconversion loss. Each mixer is calibrated across its full band:11970K* 18 to 26.5 GHz 11970A 26.5 to 40 GHz11970Q 33 to 50 GHz 11970U 40 to 60 GHz11970V 50 to 75 GHz 11970W 75 to 110 GHzThis series of mixers has been designed for a local oscillator frequency of 3 to 6.1 GHz. Accurate absolute amplitude measurements can be made by using the mixer’s conversion loss calibration chart. The SWR of the waveguide input is typically 2.2:1 to further minimize measurement uncertainty. The combination of high gain-compression level and low conversion loss provides the maximum dynamic range for measuring input signals.* 11970K is excluded from PXA support18 to 110 GHz11970K*, 11970A, 11970Q, 11970U, 11970V, 11970W19812Easy to useThe excellent frequency response and low conversionloss are achieved without external dc bias or tuning stubs. Since bias and tuning stubs are not required, manualoperation is simplified, and the complexity of hardware and software for automatic systems is greatly reduced. The repeatability of amplitude measurements is also enhanced. The dual-diode design of the mixers further simplifiesmeasurements by suppressing the odd-order harmonics by more than 20 dB, which makes identification of the mixing products easier.RuggedThe rugged Agilent 11970 Series mixers willsurvive input levels up to 100 milliwatts (+20 dBm)with no damage to the mixer diodes. They will withstand shocks up to 30 G’s and the vibration required by MIL-STD 28800C, Type III, Class 3 tests.Figure 1. The 11970 Series mixers have separate LO input and IF output portsAgilent 8560E/EC Series spectrum analyzer Extended frequency 8560E/ECSeriesFrequency extension for the Agilent E4407B,8560E/EC Series, 8566B, and 71000 Series and PSA Series spectrum analyzersThe 11970 Series harmonic mixers are fully compatiblewith the Agilent E4407B, 8560E/EC Series, 8566B (requires a preamplifier), 71000, and PSA Series spectrum analyzers. Accurate frequency and amplitude measurements are made directly from the spectrum analyzer’s display after calibration using the mixer’s calibration chart.Frequency extension for the Agilent N9030A PXA Series signal analyzerThe 11970 Series harmonic mixers (11970K excluded) are also compatible with the N9030A PXA Series high-performance signal analyzer. The PXA offers optional external mixing (Option EXM), enabling it to work with the 11970 Series and other external mixers for frequency extension. An external diplexer is required because the PXA external mixing has a single SMA LO/IF port, whereas the 11970 Series mixers have separate LO and IF ports. Recommended diplexers can be purchased from Agilentas N9020A-E13, or from OML Inc. as DLP.313B.Spectrum analyzerExtended frequency PSA SeriesAgilent E4407B spectrum analyzer Extended frequency E4407B ESA-E SeriesAgilent N9030APXA Series signal analyzer Extended frequency PXA Seriesharmonic mixer3Input frequency, GHzNominal frequency response & conversion loss1826.533 40 50 60 75 110C o n v e r s i o n l o s s , d B50454035302520KAQUVWSpecificationsSpecifications describe the device’s warranted performance over the temperature range 0 to 55° C (except where noted).11970 Series tested with Agilent PSA spectrum analyzersAgilent model number Frequency range (GHz) LOharmonic number Maximum conversion loss (dB) Nominal spectrum analyzer noise (dBm)1 kHz BW Frequency response (dB) Nominal gain compression (dBm)11970K 18 to 26.56– 24 –105 ±1.9 –311970A 26.5 to 40 8– 26 –102 ±1.9 –511970Q 33 to 50 10– 28 –101 ±1.9 –711970U 40 to 60 10– 28 –101 ±1.9 –711970V 50 to 75 14– 40 –92 ±2.1 –311970W75 to 11018–46–85±3.0–1Nominal performance, as noted in the following tables, while not warranted, provides information useful in applying the device.1. An LO power of between 14.5 to 16 dBm at the mixer’s LO input is necessary to achieve the given frequency response and spectrum analyzer amplitude accuracy specifications. When LO power varies between 14 to 18 dBm at the mixer’s LO input, add ±1 dB to the frequency response and spectrum analyzer amplitude accuracy specification.4Agilent model number Flange Weight X Y Z 11970K UG-595/U WR-42 0.17 kg 0.36 lb 36 mm 1.4 in 51 mm 2.0 in 90 mm 3.5 in 11970A UG-599/U WR-28 0.14 kg 0.32 lb 36 mm 1.4 in 51 mm 2.0 in 71 mm 2.8 in 11970Q UG-383/U WR-220.14 kg 0.32 lb36 mm 1.4 in 51 mm 2.0 in 76 mm 3.0 in 11970U UG-383/U-M WR-19 0.14 kg 0.32 lb 36 mm 1.4 in 51 mm 2.0 in 76 mm 3.0 in 11970V UG-385/U WR-15 0.14 kg 0.32 lb 36 mm 51 mm 76 mm 1.4 in 2.0 in 3.0 in 11970WUG-387/U WR-100.14 kg 0.32 lb36 mm 1.4 in51 mm 2.0 in76 mm 3.0 in11970 Series tested with Agilent PXA signal analyzerAgilent model number Frequency range (GHz)LOharmonic number 1Maximum conversion loss (dB)Nominal signalanalyzer noise (dBm)21 kHz BW Frequency response (dB)Nominal gain compression (dBm)11970A 26.5 to 406–/8–26–110/–108±1.9–511970Q 33 to 50 8–/10–28–108/–106±1.9–711970U 40 to 6010–28–106±1.9–711970V 50 to 7512–/14–40 –96/–94±2.1–3 11970W75 to 11018–46 –88±3.0–11. When used with 11970 Series mixer in A-, Q-, or V-band, the PXA’s LO harmonics are automatically switched between two different numbers as listed to optimize conversion loss.2. If the LO harmonics are switched, the noise levels for the signal analyzer/mixer combination will change, corresponding to the different LO harmonic numbers.Ordering Information* Not compatible with N9030A PXA** Required if the 11970 mixer is used with the Agilent PXAWarranty and ServiceStandard warranty for 11970 mixers is 12 monthsStandard warranty for N9029A-E13 diplexer is 3 months, provided by OML, Inc./find/externalmixersAgilent Email Updates/find/emailupdatesGet the latest information on the products and applications you select.LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium.Agilent Channel Partners/find/channelpartnersGet the best of both worlds: Agilent’s measurement expertise and product breadth, combined with channel partner convenience.For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at:/find/contactus Americas Canada (877) 894 4414 Brazil(11) 4197 3500Mexico 01800 5064 800 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485China800 810 0189Hong Kong 800 938 693India 1 800 112 929Japan 0120 (421) 345Korea 080 769 0800Malaysia 1 800 888 848Singapore 180****8100Taiwan0800 047 866Other AP Countries(65) 375 8100Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15Finland 358 (0) 10 855 2100France 0825 010 700 * 0.125 €/minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204Israel 972-3-9288-504/544Italy 39 02 92 60 8484Netherlands 31 (0) 20 547 2111Spain 34 (91) 631 3300Sweden 0200-88 22 55United Kingdom 44 (0) 131 452 0200For other unlisted countries:/find/contactusRevised: June 8, 2011Product specifications and descriptions in this document subject to change without notice.© Agilent Technologies, Inc. 2011Published in USA, September 19, 20115968-1445EAgilent Advantage Services is committed to your success throughout your equipment’s lifetime. To keep you competi-tive, we continually invest in tools and processes that speed up calibration and repair and reduce your cost of ownership. You can also use Infoline Web Services to manage equip-ment and services more effectively. By sharing our measure-ment and service expertise, we help you create the products that change our world./quality/find/advantageservicesAdvancedTCA ® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the Advanced TCA for general purpose and semiconductor test. Agilent is a founding member of the AXIe consortium.PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high- performance measurement and automation system.。
Nema-7 压力 真空开关参数表说明书
81,7(' 67$7(6 ZZZRPHJDFRP 7&20(*$
6WDPIRUG &7
&$1$'$ ZZZRPHJDFD /DYDO 4XHEHF 7&20(*$
81,7(' .,1*'20 ZZZ RPHJDFRXN 0DQFKHVWHU (QJODQG
)ORZ DQG /HYHO
Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters
PSW790B-L, $370, shown smaller than actual size
Stainless Steel Actuator Seal: (psi
The OMEGA® PSW790 Series switches are designed to satisfy
OPTIONAL CONFIGURATIONS
Ordering Example: PSW790SS-L-HS has a stainless steel seal, a range of 15 psi and a hermetically sealed 11 A switch, $370 + 50 + 90 = $510.
华邦(winbond)产品手册
PRODUCT GUIDE ==Winbond、ISSI 授权香港及中国代理== 8 位单片宽工作电压系列
型号 ROM 型式 ROM RAM I/O 脚 外扩存储 器空间 64K 工作电压 定时器/ 计数器 3 封装 Int 特殊功能 PDIP 6 CMOS 通用功能 特殊 I/O 口 /INT2, /INT3,WDT 特殊 I/O 口 /INT2, /INT3,WDT 16 KB 掩膜 ROM W78L54 掩膜 16K 256 32/36 64K 5.5V - 1.8V 3 8 特殊 I/O 口 /INT2,/INT3,WDT W78L801 掩膜 4K 256 36 64K 5.5V - 1.8V 2 12 特殊 I/O 口,P1 口 退出省电方式 WDT 可多次编程,特殊 I/O 口 / INT2, /INT3, WDT 可多次编程特殊 I/O 口 / INT2, /INT3, WDT 可多次编程特殊 I/O 口 / INT2, /INT3, WDT 可多次编程,可在线编程 特殊 I/O 口/ INT2, /INT3 可多次编程,可在线编程 W78LE516 Flash EPROM 64K 512 32/36 64K 5.5V - 2.4V 3 8 特殊 I/O 口,/ INT2, /INT3, 可多次编程,可在线编程 W78LE365 Flash EPROM 64K 1280 32/36 64 K 5.5V - 2.4V 3 8 特殊 I/O 口/ INT2, /INT3,WTD,PWM 特殊 I/O 口 W78LE812 Flash EPROM 8K 256 36 64K 5.5V - 2.4V 3 14 P1 口退出省电方式 WDT,UART 40 44 44 40 44 44 40 44 44 40 44 44 40 44 44 40 PLCC 44 PQFP 44
大众合众合chunghop万能电视遥控器代码表及使用方法说明书
大众合众合chunghop万能电视遥控器代码表及使用方法说明书1大众合、众合c h u n g h o p万能电视遥控器代码表及使用方法说明书国内电视:长虹000. 008. 009. 091. 092. 093. 010. 011. 014. 016 .026. 028. 033. 051. 088.100.157.158.159. 160. 161. 180 .181. 185 .186 .191. 192 .210. 211. 212. 229. 230 .231 .232康佳011 .017 .029 .032 .034. 054 .067 .069 .071 .075 .076 .077 .078 .079 .080 .081 107 113 117. 173 .174. 175. 176. 189. 201. 202. 203. 217 .218. 220. 226 .267.236创维011. 025.033.045.046.060 .070. 017 .072. 073. 074. 079. 083.010 .107. 108 .109 162 163 .164 .165 .166 .167. 168. 169. 177. 224.225. 235. 246熊猫001. 011. 016. 021. 022. 023 .024 .025. 026. 028 .033 .040 .043. 053. 056.009. 057. 058 051. 061. 062.073. 079. 089. 091 .124 .125 .234.237. 238. 239 .240.241.242. 243. 244 245 247. 248 .249 .250. 251TCL 051.053 .068. 071 .073. 082 .083.084 .085. 110 .111 .170 .171. 172.178. 179 .187.188.197 .198.199. 200 .233海尔103 .112 .118 .119. 150. 151 .152 .153 .154 .155 .156. 182. 183. 184. 193. 194 .213 .228海信000. 006 .007. 008. 010 .014 .015. 025. 045. 046 .103. 105. 107 .115 .116 .128. 129.130.131 138 .139.150 .151 .152 .153 .154 .155 .156 .182 .183 .184 .193 .1 94 .213 .228金星007. 008. 011 .013. 024. 025. 032. 033 .039 .051 .065 .071 .073. 079 .091 .097 .138福日007 .011 .015 .023.024. 028. 033. 034. 040. 043. 053. 056. 060 .061 .065 .079安华ANHUA 017. 001. 032. 047百花BAIHUA 016. 025 .033 .053. 056. 079百合花BAIHEHUA 023. 024. 040. 043百乐BAILE 016. 025. 012 .019. 026. 027.028. 029 .030. 031. 042 宝声BAOSHENG 011. 025. 016北京008 .012.011. 019 .016. 023. 024. 025. 027 .028.029 .030. 031. 033 .044 .043 .050 .053 .056 .026 .079.091 .039. 042.051. 021. 122 .126宝花石BaoHuaShi 033.053.056. 079彩虹CAIHONG 011. 025. 016彩星CAIXING 023. 024. 040 .043长城011 .016 .017. 023 .024 .025.033. 040 .043 .053. 056 .001 .012. 029 .027 .026.028 .029.030031 .042. 079海虹HAIHONG 016 .025 .026 .027. 028 .029 .030海乐HAILE 032. 047海燕HAIYAN 011. 023. 024 .033. 040. 043.053 .056. 079环宇HUANY 011.015. 023. 024. 033 .040. 043. 053. 056 .009. 057. 058虹美HONGMEI 003. 011. 016 .018 .023. 024. 025 .033 .040. 043. 056. 009.057 .058. 079红岩HONGYAN 011.033. 053. 056. 079菊花JUHUA 011.023.024.033.040.43.053.056.079金海JINHAI 009.057.058金凤JINFENG 001.011.021.022金塔JINTA 016.023.024.025.033.040.043.053.056.009.057.058.079 金鹊JINQUE 011.025.016金雀JINQUE 032.033.053.056.079嘉华JIAHUA 017.047.001.032昆仑KUNLUN 001.011.021.022.033.025.012.042.040.039凯歌KAIGE 011.016.023.024.025.033.040.043.053.056.079康力KANGLI 027.012.019.025.026.028.030.031.033.120康虹KANGHONG 009.058.057康立KANGLI 016.023024.025.040.043.011.026.029.042.005康艺KANGYI 016.025.033.053.056.079.121孔雀KONGQUE 011.016.023.024.025.033.040.041.043.124快乐KUAILE 016.025.033.053.056.079乐华ROWA 011.016.023.024.025.040.043.096.127龙江LONGJIANG 011.033.053.056.079利华LIHUA 011牡丹MUDAN 001.002.011.016.020.021.022.025.032.033.040.043.053.056.059.063.065.079美乐MEILE 011.023.024.033.040.043.053.056.009.057.058.079梦寐MENGMEI 023.024.040.043南声NANSHENG 011.033.053.056.079青岛QINGDAO 001.011.021.022.033.053.056.079如意RUYI 011.015.023.024.040.043神彩SHENCAI 007.016.025.033.053.056.079山茶SHANGCAI 011.033.053.056.079上海SHANGHAI 011.016.017.022.023.024.025.033.040.043.0053.056.009.057.058.079.123韶峰SHAOFENG 011.015.000.006.007.023沈阳SHENGYAN 011.016.025.046.045.033塞格SAIGE 011.025.016松柏SONGBA 016.025三元SANYUAN 003.011.016.018.023.024.025.040.043三键SANJIAN 033.053.056.079泰山TAISHAN011.016.025.042.038.031.030.029.028.027天鹅TIANE 003.011.018通广TONGGUANG 033.053.056.079威牌WEIPAI 016.025翔宇XIANGYU 016.025.032西湖XIHU 011.023.024.033.038.040.43.053.079.098厦华XIAHUA 011.016.024.027.025.033.053.054.055.056.06.098.08 0.095.079.073雪莲XUELIAN 023.024.040.043.009.057.058星海XINGHAI 016.025.033.053.056.079襄阳XIANGYANG 033.053.056.079幸福XINGFU 016.025万能遥控器使用方法代码自定义搜索万能遥控器的代码自定义搜索的方法:1、左手先按住“设置”键不松手,再用右手按一下“电源”键,指示灯变成长亮。
AWWA-C200-97
American Water Works AssociationANSI/AWWA C200-97(Revision of ANSI/AWWA C200-91)RA WWA STANDARDFORSTEEL W ATER PIPE—6 IN. (150 mm)AND LARGEREffective date: Oct. 1, 1997.First edition approved by AWWA Board of Directors Jan. 26, 1975.This edition approved Feb. 2, 1997.This edition approved by American National Standards Institute July 3, 1997.AMERICAN WATER WORKS ASSOCIATION6666 West Quincy Avenue,Denver,Colorado80235A WW A StandardThis document is an American Water Works Association (AWWA) standard. It is not a specification. AWWA standards describe minimum requirements and do not contain all of the engineering and administrative information normally contained in specifications. The AWWA standards usually contain options that must be evaluated by the user of the standard. Until each optional feature is specified by the user, the product or service is not fully defined. AWWA publication of a standard does not constitute endorsement of any product or product type, nor does AWWA test, certify, or approve any product. The use of AWWA standards is entirely voluntary. AWWA standards are intended to represent a consensus of the water supply industry that the product described will provide satisfactory service. When AWWA revises or withdraws this standard, an official notice of action will be placed on the first page of the classified advertising section of Journal AWWA. The action becomes effective on the first day of the month following the month of Journal AWWA publication of the official notice.American National StandardAn American National Standard implies a consensus of those substantially concerned with its scope and provisions. An American National Standard is intended as a guide to aid the manufacturer, the consumer, and the general public. The existence of an American National Standard does not in any respect preclude anyone, whether that person has approved the standard or not, from manufactur-ing, marketing, purchasing, or using products, processes, or procedures not conforming to the standard. American National Standards are subject to periodic review, and users are cautioned to obtain the latest editions. Producers of goods made in conformity with an American National Standard are encouraged to state on their own responsibility in advertising and promotional materials or on tags or labels that the goods are produced in conformity with particular American National Standards.C AUTION N OTICE:The American National Standards Institute (ANSI) approval date on the front cover of this standard indicates completion of the ANSI approval process. This American National Standard may be revised or withdrawn at any time. ANSI procedures require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of publication. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute, 11W.42nd St., New York,NY10036; (212)642-4900.Copyright © 1997 by American Water Works AssociationPrinted in USACommittee PersonnelThe AWWA Standards Committee on Steel Pipe, which reviewed and approved this standard, had the following personnel at the time of approval:George J. Tupac, ChairJohn H. Bambei Jr., Vice-ChairDennis A. Dechant, SecretaryConsumer MembersG.A. Andersen, New York City Bureau of Water Supply, Corona, N.Y.(AWWA) Ergun Bakall, San Diego County Water Authority, San Diego, Calif.(AWWA) J.H. Bambei Jr., Denver Water Department, Denver, Colo.(AWWA) J.L. Doane, Portland Water Bureau, Portland, Ore.(AWWA) R.V. Frisz, US Bureau of Reclamation, Denver, Colo.(USBR) T.J. Jordan, Metropolitan Water District of Southern California,LaVerne, Calif.(AWWA) W.M. Kremkau, Washington Suburban Sanitary Commission, Laurel, Md.(AWWA) T.A. Larson, Tacoma Water Division, Tacoma, Wash.(AWWA) P.W. Reynolds, Los Angeles Department of Water and Power,Los Angeles, Calif.(AWWA) G.M. Snyder, Metropolitan Water District of Southern California,Los Angeles, Calif.(AWWA) M.L. Young, East Bay Municipal Utility District, Stockton, Calif.(AWWA)General Interest MembersG.E. Block Jr., Rizzo Associates Inc., Natick, Mass.(NEWWA) W.R. Brunzell, Brunzell Associates Ltd., Skokie, Ill.(AWWA) B.R. Bullert,* Council Liaison, City of St. Paul Water Utility,St. Paul, Minn.(AWWA) R.L. Coffey, R.W. Beck Inc., Seattle, Wash.(AWWA) B.R. Elms,* Standards Engineer Liaison, AWWA, Denver, Colo.(AWWA) L.J. Farr, CH2M Hill Inc., Redding, Calif.(AWWA) K.G. Ferguson, Montgomery Watson, Las Vegas, Nev.(AWWA) S.N. Foellmi,† Black & Veatch Engineers, Irvine, Calif.(AWWA) J.W. Green, Alvord Burdick & Howson, Chicago, Ill.(AWWA) K.D. Henrichsen, HDR Engineering Inc., Denver, Colo.(AWWA) G.K. Hickox, Engineering Consultant, Houston, Texas(AWS) M.B. Horsley, Black & Veatch, Kansas City, Mo.(AWWA) J.K. Jeyapalan, American Ventures Inc., Bellevue, Wash.(AWWA) R.Y. Konyalian, Boyle Engineering Corporation, Newport Beach, Calif.(AWWA) H.R. Stoner, Henry R. Stoner Associates Inc., North Plainfield, N.J.(AWWA) Chris Sundberg† CH2M Hill Inc., Bellevue, Wash.(AWWA) *Liaison, nonvoting†AlternateG.J. Tupac, G.J. Tupac & Associates, Pittsburgh, Pa.(AWWA) L.W. Warren, KCM Inc., Seattle, Wash.(AWWA) W.R. Whidden, Post Buckley Schuh & Jernigan, Winter Park, Fla.(AWWA) R.E. Young, Robert E. Young Engineers, Sacramento, Calif.(AWWA)Producer MembersH.H. Bardakjian, Ameron Concrete & Steel Pipe, RanchoCucamonga, Calif.(AWWA) T.R. Brown, Smith-Blair Inc., Uniontown, Pa.(AWWA) J.H. Burton, Baker Coupling Company Inc., Los Angeles, Calif.(AWWA) R.J. Card, Brico Industries Inc., Atlanta, Ga.(AWWA) J.R. Davenport, California Steel Pressure Pipe, Riverside, Calif.(AWWA) Dennis Dechant, Northwest Pipe & Casing Company, Portland, Ore.(AWWA) G.M. Harris, Harris Corrosion Specialist, Longboat Key, Fla.(AWWA) J.R. Pegues, American Cast Iron Pipe Company, Birmingham, Ala.(MSS) Bruce Vanderploeg,* Northwest Pipe & Casing Company, Portland, Ore.(AWWA) J.A. Wise, Canus Industries Inc., Burnaby, B.C.(AWWA) *AlternateContentsAll AWWA standards follow the general format indicated subsequently. Some variations from this format may be found in a particular standard.SEC.PAGE SEC.PAGEForewordI Introduction (vii)I.A Background (vii)I.B History (vii)I.C Acceptance (viii)II Special Issues (ix)II.A Advisory Information on ProductApplication (ix)III Use of This Standard (x)III.A Purchaser Options and Alternatives (x)III.B Modification to Standard (xi)IV Major Revisions (xi)V Comments (xi)Standard1General1.1Scope (1)1.2Purpose (1)1.3Application (1)2References (1)3Definitions (3)4Requirements4.1Permeation (5)4.2Materials and Workmanship (5)4.3Drawings (6)4.4Calculations (6)4.5Protective Coating (6)4.6Pipe Made to ASTM Requirements (6)4.7Fabricated Pipe (6)4.8Selection of Materials (7)4.9General Requirements forFabrication of Pipe............................74.10Fabrication of Pipe. (7)4.11Requirements for WeldingOperations (8)4.12Permissible Variations in Weightsand Dimensions (10)4.13Preparation of Ends (13)4.14Special Ends (16)4.15Specials and Fittings (16)4.16Fabrication of Specials (16)5Verification5.1Inspection (16)5.2Test Procedures (17)5.3Calibration of Equipment (18)6Delivery6.1Marking (18)6.2Handling and Loading (19)6.3Affidavit of Compliance (19)Figures1Reduced-Section Tension TestSpecimen (9)2Guided-Bend Test Specimen (10)3Jig for Guided-Bend Test (11)4Alternative Guided-Bend Wrap-Around Jig (12)5Alternative Guided-Bend RollerJig (13)Tables1Steel Plate, Sheet, or Coils forFabricated Pipe (7)2Guided-Bend Test Jig Dimensions....12This page intentionally blank.ForewordThis foreword is for information only and is not a part of AWWA C200.I.Introduction.I.A.Background.This standard covers butt-welded, straight seam or spiral seam steel pipe, 6in. (150mm) and larger, for transmission and distribution of water, including fabrication of pipe, requirements of welding operations, permissible variations of weight and dimensions, preparation of ends, fabrication of specials, inspection, and test procedures.I.B.History.The first AWWA steel pipe standards issued were 7A.3 and 7A.4, published in 1940. Standard 7A.4 pertained to steel pipe smaller than 30in. (750mm) in diameter, and 7A.3 pertained to steel pipe 30in. (750mm) in diameter and larger. Subsequently, in recognition that some pipe used in water utility service was manufactured in steel mills rather than in a fabricator’s shop, two new AWWA standards were issued in 1960. AWWA C201 replaced 7A.3 and pertained to all pipe, regardless of diameter, manufactured in a fabricator’s shop from steel sheet or plate. The physical and chemical properties are properties of the sheet or plate from which the pipe is made. The properties are a function of the steel mill practice and are not affected significantly by fabricating procedures. AWWA C202 replaced 7A.4 and pertained to mill pipe, which is normally produced in a production pipe mill. The specified physical and chemical properties are those of the completed pipe. Physical testing is performed on the pipe rather than on the steel from which it originates. In many cases, the physical properties are significantly affected by the pipe-manufactur-ing procedure. AWWA C201 was revised in 1966, and AWWA C202 was revised in 1964. Both AWWA C201 and AWWA C202 were superseded by AWWA C200-75, approved by the AWWA Board of Directors on Jan.26, 1975.AWWA C200 includes all types and classes of steel pipe, 6in. (150mm) in diameter and larger, used in water utility service, regardless of the pipe manufactur-ing source. With adequate quality assurance, pipe manufactured in a fabricator’s shop or in a steel pipe mill is suitable for water utility service. Pipe produced in a pipe mill according to one of the ASTM* standards cited in AWWA C200 will be subjected to specific quality-control procedures so that no further testing is required by AWWA C200. Shop-fabricated pipe made from materials and in accordance with the quality-control measures stipulated in AWWA C200 will be of high quality.By reference, AWWA C202 (which pertained to mill-type steel water pipe) included API† 5L and API 5LX pipe grades manufactured to API standards for high-pressure applications. With the inclusion of ASTM A570/A570M and ASTM A572/ A572M high-strength steels in AWWA C200, API high-pressure pipe was omitted from AWWA C200 as being redundant. However, API 5L and API 5LX pipe grades fully meet all requirements of AWWA C200 and can be used for water utility applications if dictated by availability or other economic considerations.*American Society for Testing and Materials, 100 Barr Harbor Dr., West Conshohocken, PA 19428-2959.†American Petroleum Institute, 1220 L St. N.W., Washington, DC 20005.AWWA C200-75 introduced design criteria for determination of wall thickness to meet internal pressure conditions. This facilitated the selection of the optimum combination of thickness and material for steel pipe.Revisions in ANSI/AWWA C200-86 included clarification of forming for lap joint ends and gasketed ends and testing of O-ring gaskets. ANSI/AWWA C200-91 was approved by the AWWA Board of Directors on June23, 1991. This edition was approved by the AWWA Board of Directors on Feb.2, 1997.I.C.Acceptance.In May 1985, the US Environmental Protection Agency (USEPA) entered into a cooperative agreement with a consortium led by NSF International (NSF) to develop voluntary third-party consensus standards and a certification program for all direct and indirect drinking water additives. Other members of the original consortium included the American Water Works Association Research Foundation (AWWARF) and the Conference of State Health and Environ-mental Managers (COSHEM). The American Water Works Association (AWWA) and the Association of State Drinking Water Administrators (ASDWA) joined later.In the United States, authority to regulate products for use in, or in contact with, drinking water rests with individual states.* Local agencies may choose to impose requirements more stringent than those required by the state. To evaluate the health effects of products and drinking water additives from such products, state and local agencies may use various references, including1.An advisory program formerly administered by USEPA, Office of Drinking Water, discontinued on Apr.7, 1990.2.Specific policies of the state or local agency.3.Two standards developed under the direction of NSF, ANSI†/NSF‡60, Drinking Water Treatment Chemicals—Health Effects, and ANSI/NSF61, Drinking Water System Components—Health Effects.4.Other references, including AWWA standards, Food Chemicals Codex, Water Chemicals Codex,§ and other standards considered appropriate by the state or local agency.Various certification organizations may be involved in certifying products in accordance with ANSI/NSF61. Individual states or local agencies have authority to accept or accredit certification organizations within their jurisdiction. Accreditation of certification organizations may vary from jurisdiction to jurisdiction.Appendix A, “Toxicology Review and Evaluation Procedures,” to ANSI/NSF61 does not stipulate a maximum allowable level (MAL) of a contaminant for substances not regulated by a USEPA final maximum contaminant level (MCL). The MALs of an unspecified list of “unregulated contaminants” are based on toxicity testing guidelines (noncarcinogens) and risk characterization methodology (carcinogens). Use of Appendix A procedures may not always be identical, depending on the certifier.*Persons in Canada, Mexico, and non-North American countries should contact the appropriate authority having jurisdiction.†American National Standards Institute, 11 W. 42nd St., New York, NY 10036.‡NSF International, 3475 Plymouth Rd., Ann Arbor, MI 48106.§Both publications available from National Academy of Sciences, 2102 Constitution Ave.N.W., Washington, DC 20418.AWWA C200-97 does not address additives requirements. Thus, users of this standard should consult the appropriate state or local agency having jurisdiction in order to1.Determine additives requirements, including applicable standards.2.Determine the status of certifications by all parties offering to certify products for contact with, or treatment of, drinking water.3.Determine current information on product certification.II.Special Issues.II.A.Advisory Information on Product Application.Basis of design.ANSI/AWWA C200-97 pertains to the manufacture and testing of the steel-pipe cylinder. Overall design of steel pipelines is described in AWWA Manual M11, Steel Pipe—A Guide for Design and Installation. Coatings that protect against corrosion are referenced in Sec.4.5 of ANSI/AWWA C200-97.The determination of the wall thickness of steel pipe is affected by (1)internal pressure, including operating static and transient pressures; (2)external loads,including trench loading and earth fill; (3)special physical loading, such as continuous-beam loading with saddle supports or ring girders, vacuum conditions,type of joint used, and variations in operating temperature; and (4)practical considerations for handling, shipping, lining and coating, or similar operations.The design techniques described in AWWA Manual M11 are used to determine minimum wall thicknesses of steel pipe. The purchaser may establish and specify the wall thickness determined to be satisfactory for all conditions, including internal pressure. Selection of design stresses and deflection limits should be made with regard to the properties of the lining and coating materials used. Alternatively , the purchaser may establish and specify the minimum wall thickness that will satisfy all conditions of external pressure and trench loadings and special physical loadings.The manufacturer is allowed to select materials and manufacturing processes within the limitations of this standard in order to produce pipe to the wall thickness required to additionally satisfy specified internal pressure. The purchaser should specify the internal design pressure and show the depth of cover over the pipe together with installation conditions. The manufacturer should select and furnish pipe having a wall thickness that meets the requirements of the internal design pressure and external load design. This thickness should govern if it is greater than the minimum thickness specified by the purchaser. To meet the requirements of internal design pressure, the pipe wall thickness is determined by using the following formula:(Eq F .1)Where:t =design nominal wall thickness for the specified internal design pressures.Thickness and weight tolerances for pipe shall be governed by therequirements of the specification to which the plates or sheets are ordered(in. [mm])P =internal design pressure (psi [kPa])—specified by the purchaserD =outside diameter of the steel pipe cylinder (in. [mm])t PD 2S-------=S=design stress (psi [kPa]), not to exceed the purchaser-specified percentage of the minimum yield point of thesteel selected by the manufacturerApplication.This standard covers the requirements for steel water pipe for use in water transmission and distribution under normal circumstances. It is the responsibility of the purchaser for each project to determine if any unusual circumstances related to the project require additional provisions that are not included in the standard. Such special conditions might affect design, manufacture, quality control, corrosion protection, or handling requirements.Brittle fracture precautions.Under certain conditions where a restrained pipeline with welded lap joints has a pipe wall thickness in excess of 1⁄2in. (12.7mm) and the pipeline is to be operated at high stress levels at temperatures below 40°F(5°C), the purchaser should take precautions to prevent brittle fracture, which can result from a combination of notches and high stress concentrations at the joints. Precautions may include specifying a steel with adequate notch toughness and transition temperature; and fabrication techniques that would reduce the possibility of brittle fracture.N OTE: For more information on brittle fracture, refer to AWWA Manual M11, Steel Pipe—A Guide for Design and Installation; and R.V. Phillips et al., “Pipeline Problems—Brittle Fracture, Joint Stresses, and Welding,” Journal AWWA, 64:7:421 (July 1972).Rubber-gasketed joints. A gasket manufactured from natural rubber or 100percent synthetic polyisoprene, if improperly installed, may revert to its uncured state through hysteresis. This condition may occur if a fish-mouthed gasket (that is, where a portion of the gasket is not contained within the gasket groove) is subjected to heat generated by excessive vibration caused by leakage past the gasket when the pipeline is pressurized.Testing of special sections.Section5.2.2.1 provides for nondestructive testing of the seams of specials. This testing should be adequate for normal conditions previously discussed under Application. Section5.2.2.2 describes test methods that may be necessary if, in the opinion of the purchaser, unusually severe conditions exist, such as surge or transient pressures that cause stresses exceeding 75 percent of yield. This special testing must be specified by the purchaser.Roundness of pipe.The roundness of pipe during handling, shipping, joint makeup, and backfilling should be covered in the purchaser’s specifications. Pipe may have to be stulled so it will remain round during transportation, installation, and backfilling.e of This Standard.AWWA has no responsibility for the suitability or compatibility of the provisions of this standard to any intended application by any user. Accordingly, each user of this standard is responsible for determining that the standard’s provisions are suitable for and compatible with that user’s intended application.III.A.Purchaser Options and Alternatives.The following items should be included in the purchaser’s specifications.1.Standard used—that is, AWWA C200, Standard for Steel Water Pipe—6In. (150mm) and Larger, of latest revision.2. A description or drawings indicating the diameter and total quantity of pipe required for each diameter.3.Internal design pressure.4.Design stress in pipe wall at specified internal design pressure as apercentage of minimum yield point of the steel.5.Minimum wall thickness required by considerations other than internaldesign pressure, such as allowable deflection; depth of cover; and if aboveground,distance between supports.6.Instructions regarding inspection at place of manufacture (Sec.5.1).7.The drawings and calculations to be furnished by the manufacturer ifrequired (Sec.4.3 and 4.4).8.Protective coating (Sec.4.5).9.Requirements for marking, line diagrams, or laying schedules (Sec.6.1).10.Special handling requirements for coated or lined pipe (Sec.6.2).11.Affidavit of compliance if required (Sec.6.3).12.Specification of pipe or steel if there is a preference (Sec.4.6), or desiredphysical properties for “ordering to chemistry only” (Sec.3(19) and 4.7.2).13.Manual welding (Sec.4.11.3).14.Qualification code for manual welders if different from Sec.4.11.3.1.15.Minimum hydrostatic test pressure if different from Sec.5.2.1.16.Length of pipe sections, random or specified lengths (Sec.4.12.4).17.Type of pipe ends (description or drawings) (Sec.4.13).18.Drawings of butt straps and instructions as to whether butt straps are to besupplied separately or attached to the pipe (Sec.4.13.5).19.Requirements for reports of tests of rubber-gasket materials (Sec.4.13.6.3).20.All special sections, indicating for each component part the dimensions orstandard designation (Sec.4.15) and the grade of material required (Sec.4.16).21.Method of nondestructive testing to be used for special sections (Sec.5.2.2.1)or, in the case of severe service conditions, the requirements for hydrostatic testing ofspecial sections (Sec.5.2.2.2).22.Toughness requirements (Table1).III.B.Modification to Standard.Any modification to the provisions, defini-tions, or terminology in this standard must be provided in the purchaser’sspecifications.IV.Major Revisions.Major revisions made to the standard in this editioninclude the following:1.The format has been changed to AWWA standard style.2.The acceptance clause (Sec.I.C) has been revised to approved wording.3.Table1 was revised to add ASTM A607/607M, grades45 and 50; ASTMA907/907M, grades30, 33, 36, and 40; ASTM A935/935M, grades45 and 50; andASTM A936/936M, grade50. Also, a requirement for a minimum average Charpy V-Notch value of 25lbf·ft (33.9N·m) at 30°F (–1°C) for steel plate under certain conditions was added.4.ASTM A635/A635M was added to Sec.4.7.3.5.Sec.4.11.2.1 was revised to include qualification of welding procedures.6.The definition of P in Eq1 was revised.ments.If you have any comments or questions about this standard,please call the AWWA Standards and Materials Development Department, (303) 794-7711 ext.6283, FAX (303) 795-1440, or write to the department at 6666 W. QuincyAve., Denver, CO 80235.xiThis page intentionally blank.1RAmerican Water Works AssociationANSI/AWWA C200-97(Revision of ANSI/AWWA C200-91)A WWA STANDARD FORSTEEL W ATER PIPE—6 IN. (150 mm)AND LARGERSECTION 1:GENERALSec. 1.1ScopeThis standard covers electrically butt-welded straight-seam or spiral-seam pipeand seamless pipe, 6in. (150mm)* in nominal diameter and larger, for the transmissionand distribution of water or for use in other water system facilities.Sec. 1.2PurposeThe purpose of this standard is to provide the minimum requirements for steelwater pipe, 6in. (150mm) and larger, including materials and workmanship,fabrication of pipe, specials, and fittings.Sec. 1.3ApplicationThis standard can be referenced in specifications for steel water pipe, 6in.(150mm) and larger. The stipulations of this standard apply when this document hasbeen referenced and then only to steel water pipe, 6in. (150mm) and larger.SECTION 2:REFERENCESThis standard references the following documents. In their latest editions, theyform a part of this standard to the extent specified within the standard. In any case of conflict, the requirements of this standard shall prevail.*Metric conversions given in this standard are direct conversions of US customary units andare not those specified in the International Organization for Standardization (ISO) standards.2AWWA C200-97ANSI*/ASME†—Boiler and Pressure Vessel Code, Sec. IX.ANSI/ASTM A36/A36M—Standard Specification for Carbon Structural Steel.ANSI/ASTM A53—Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless.ANSI/ASTM A134—Standard Specification for Pipe, Steel, Electric-Fusion (Arc)-Welded (Sizes NPS 16 and over).ANSI/ASTM A135—Standard Specification for Electric-Resistance-Welded Steel Pipe.ANSI/ASTM A139/A139M—Standard Specification for Electric-Fusion (Arc)-Welded Steel Pipe (NPS 4 and over).ASTM A283/A283M—Standard Specification for Low and Intermediate Tensile Strength Carbon Steel Plates.ANSI/ASTM A370—Standard Test Methods and Definitions for Mechanical Testing of Steel Products.ASTM A568/A568M—Standard Specification for Steel, Sheet, Carbon and High-Strength, Low-Alloy, Hot-Rolled and Cold-Rolled, General Requirements for.ASTM A570/A570M—Standard Specification for Steel, Sheet and Strip, Carbon, Hot-Rolled, Structural Quality.ANSI/ASTM A572/A572M—Standard Specification for High-Strength Low-Alloy Columbium-Vanadium Structural Steel.ANSI/ASTM A607—Standard Specification for Steel, Sheet and Strip, High-Strength, Low-Alloy, Columbium or Vanadium, or Both, Hot-Rolled and Cold-Rolled.ASTM A635/A635M—Standard Specification for Steel, Sheet and Strip, Heavy-Thickness Coils, Carbon, Hot-Rolled.ASTM A907/A907M—Standard Specification for Steel, Sheet and Strip, Heavy Thickness Coils, Carbon, Hot-Rolled, Structural Quality.ASTM A935/A935M—Standard Specification for Steel, Sheet and Strip, Heavy Thickness Coils, High Strength, Low-Alloy, Columbium or Vanadium, or Both, Hot-Rolled.ASTM A936/A936M—Standard Specification for Steel, Sheet and Strip, Heavy Thickness Coils, High Strength, Low-Alloy, Hot-Rolled, with Improved Formability.ASTM D297—Standard Test Methods for Rubber Products—Chemical Analysis.ASTM D395—Standard Test Methods for Rubber Property—Compression Set.ASTM D412—Standard Test Methods for Vulcanized Rubber and Thermoplastic Rubbers and Thermoplastic Elastomers—Tension.ASTM D573—Standard Test Method for Rubber-Deterioration in an Air Oven.ASTM D2240—Standard Test Method for Rubber Property—Durometer Hardness.ASTM E340—Standard Test Method of Macroetching Metals and Alloys.ANSI/AWS‡ A3.0—Standard Welding Terms and Definitions Including Terms for Brazing, Soldering, Thermal Spraying and Thermal Cutting.AWS B2.1—Standard for Welding Procedure and Performance Qualification.AWS QC 1—Standard for AWS Certification of Welding Inspectors.*American National Standards Institute, 11 W. 42nd St., New York, NY 10036.†American Society of Mechanical Engineers, 345 E. 47th St., New York, NY 10017.‡American Welding Society, 550 N.W. LeJeune Rd., Miami, FL 33135.。
AXP209 Datasheet v1.0(中文)
AXP209 集成了一个自适应的 USB-Compatible 的 PWM 充电器,2 路降压转换器(Buck DC-DC converter),5 路线性稳压器(LDO),电压/电流/温度等多路 12-Bit ADC,以及 4 路可配置的 GPIO。为保 证电源系统安全稳定,AXP209 还整合了过/欠压(OVP/UVP)、过温(OTP)、过流(OCP)等保护电路。