US_Fenton试剂法在水体系中降解对硝基苯酚的研究

合集下载

微波耦合类Fenton处理水中对硝基苯酚

微波耦合类Fenton处理水中对硝基苯酚

微波耦合类Fenton处理水中对硝基苯酚潘维倩;张广山;郑彤;张洁;王鹏【期刊名称】《中国环境科学》【年(卷),期】2014(000)012【摘要】针对对硝基苯酚环境危害大、难生物降解的特点,为克服传统 Fenton 适用 pH 范围窄的缺点,制备了 CuO 催化剂,并对微波耦合类Fenton氧化对硝基苯酚溶液进行了实验研究,考察了H2O2投加量、催化剂投加量、微波功率、辐照时间、溶液初始pH对PNP去除效果的影响.结果表明,在 H2O2和催化剂投加量分别为0.06mol/L 和0.3g/L,微波功率125W,不调节溶液初始 pH(约为6)的条件下,初始浓度为50mg/L的PNP溶液反应6min去除率达92%, TOC去除63%.比较不同氧化体系,得到微波能够增大微波耦合类Fenton体系中•OH的生成量,从而提高对PNP的去除率.实验表明,CuO催化微波耦合类Fenton作为一种新型类Fenton反应,能克服传统Fenton适用pH范围窄的局限性,并且显著提高反应效率,拓展了Fenton反应在废水处理中的应用.【总页数】7页(P3112-3118)【作者】潘维倩;张广山;郑彤;张洁;王鹏【作者单位】哈尔滨工业大学市政环境工程学院,黑龙江哈尔滨150090;哈尔滨工业大学市政环境工程学院,黑龙江哈尔滨150090;哈尔滨工业大学市政环境工程学院,黑龙江哈尔滨150090;哈尔滨工业大学市政环境工程学院,黑龙江哈尔滨150090;哈尔滨工业大学市政环境工程学院,黑龙江哈尔滨150090; 哈尔滨工业大学城市水资源与水环境国家重点实验室,黑龙江哈尔滨 150090【正文语种】中文【中图分类】X703.1【相关文献】1.微波耦合类Fenton处理水中对硝基苯酚 [J], 潘维倩;张广山;2.非均相微波协同类Fenton催化降解废水中的苯酚 [J], 杨帆;刘志英;赵浩;徐学骁;徐炎华3.类Fenton氧化-絮凝耦合处理染料中间体废水 [J], 范先媛;周志辉;余微;朱小丽;陈士祥4.光助非均相类Fenton法对对硝基苯酚废水的处理 [J], 班福忱;赵鑫宇;王闯;孙晓昕5.Fenton和类Fenton技术处理水中盐酸四环素试验研究 [J], 宋成智;张娇;李依;杨阳阳;韩岗华因版权原因,仅展示原文概要,查看原文内容请购买。

Fenton试剂在水处理中的应用研究

Fenton试剂在水处理中的应用研究
年 H. E sn o sr R. i h u e 首次 使用 F no e e tn试 剂处 理 苯 酚及烷 基苯 废水 , 开创 了 F no e tn试 剂在废 水处 理 领
域 的先 河 。此 后 , e tn试 剂在 废 水 处理 中的 研究 F no 与应用 日益受 到 国内外 的关 注 。
e t n i g t e o i a i n o n o y mea a in d p n UV. e mo i c to t o s t n b e F n o e g n s x e d n h x d t f Fe t n b t l t o i g。 o c o Th d f a i n me h d o e a l e t n r a e t i t p r t r e l wi n t i e iw. o o e a ea e d a t t i hs r ve h
的有 机物 质相 比毒 性 降低 且 更 利 于 生 物 降解 , 这使
得含这 些污 染物 的 废 水能 更 好 地 被 后续 生 化 处 理 。 大量试验 研究 表 明 , e tn试 剂 能 不 同程 度 地去 除 F no
用, 后人将 H2 和 F外命 名 为 F no 02 e etn试剂 。16 94
水体 中的有机 污染 物 , 如硝基 苯 、 稠环 芳烃 、 氯酚 、 二
除草 剂 ( zp ) 甲基叔 丁基 醚 、 氯 乙烯 、 i ay、 ma 三 偶氮 染
料 ( 7 直接红 和 分散 黄) 硝基苯 、 AO , 、 垃圾 渗 滤液 等 。 影 响 该 系 统 的 主要 因 素 为 : H 值 、 留 时 间 、 p 停
Hz z 用 率 是 目前 研 究 的关 键 。 目前 其 他 替 代 离 子 的 研 究 和 紫 外 光 技 术 的 引 入 取 得 了 很 大 的 进 展 , 文 综 述 了 0利 本 目前 的研 究 现 状 , 对 今 后 的研 究 提 出 了展 望 。 并

芬顿试剂处理有机废水的研究进展-推荐下载

芬顿试剂处理有机废水的研究进展-推荐下载

芬顿法处理有机废水的研究与应用进展摘要:芬顿法是一种高级的氧化技术, 具有较高的去除难降解有机污染物的能力。

本人分别介绍了普通芬顿法、光-芬顿法以及电-芬顿法的氧化机理,并概述了芬顿法在有机废水处理中的应用进展。

关键词:芬顿法氧化机理有机废水中图分类号: X703文献标识码:A1894年,化学家 Fenton HJ 发现,过氧化氢(H2O2 )与二价铁离子 Fe2 +的混合溶液具有强氧化性,可以将当时很多已知的有机化合物如羧酸、醇、酯类氧化为无机态,对于其中比较一般的有机物可完全被氧化为无机态,氧化效果十分明显。

但因其氧化性极强,难以作为有机合成所需的选择性氧化剂,此后半个多世纪中,人们对这种氧化性试剂的应用并不多。

直到进入20世纪70年代,芬顿试剂才在环境化学中找到了它的位置。

20世纪70年代,水环境的污染成为世界性难题,而持久性有机污染物(指难降解的有机物)的降解问题,是污染控制化学中的研究重点。

环境化学家们不久就发现,已沉寂了半个多世纪的芬顿试剂在氧化降解持久性有机污染物方面有独特的优势。

不久芬顿试剂用于氧化降解持久性有机物的报道便不断出现。

到目前作为废水的深度氧化法(AOP)中的一主流方法,芬顿试剂的应用范围正在不断扩展。

1894 年,法国科学家Fenton 发现,在酸性条件下,Fe2+/H2O2 可以有效氧化酒石酸,后人为了纪念这一发现,将Fe2+/H2O2 命名为芬顿试剂。

1964 年,加拿大学者Eisenhaner 首次将芬顿试剂应用到水处理中。

他用芬顿试剂处理ABS 废水,ABS的去除率高达99%。

芬顿氧化技术具有高效、廉价、选择性小等特点,芬顿氧化法作为一种高级氧化技术(Advanced Oxidation Process,AOP)应用于环境污染物处理领域,引起了国内外科学家的极大关注。

芬顿试剂具有很强的氧化性,而且其氧化性没有选择性,能适应各种废水的处理,已有的研究表明,采用芬顿反应可有效的处理废水中的酚类、苯胺类、杂环类等有机物,对于医药废水、农药废水、焦化废水都有很好的处理效果。

碱度对UV-Fenton法降解对硝基苯酚的影响

碱度对UV-Fenton法降解对硝基苯酚的影响

含 酚废 水 主要 来 自焦 化 厂 、煤 气 厂 和 化工 厂 等 。其 中含 有 大 量 苯 酚 、硝 基 酚 、 甲基 酚 、氯 酚 等 ,是水体 污染 的主要 来源之 一 ,如 何有效 处理该 类 废 水 是 当前 水 污 染 防 治 的重 要 任 务 之 一 。U V—
E e to la i i n d g a a in o -Ni o h n l f c fa k l t o e r d t fp ny o t p e o r
b y UV-F n in r a e t e t e g n o
L n, JN Gu - u , Z I Ya I o h a HOU Z o mig u — n
( eate go n i n e t n i e n H a i nvr t Q azo 6 0 1 C i ) D p r n E vr m n l gn d  ̄ uqa U i sy unhu3 22 , hn m f o aE e o e i, a
A s at h f cs fn il H adakl i ntedga ai - io h n lp N b V F nin b t c :T ee eto ia p n la nt o erd t no p N t p e o( - P) yU / et r f it i y h o f r o poes a v sgtd T e eut so e a,cdc o dt ( Hw s rcs sn et a . h sl w dt taii c n i n p a w i i e r sh h o 3—5 b n fe e e rd t no N , ) eei dt ga a o f - P t hd i p
维普资讯
I U R L AE & A ቤተ መጻሕፍቲ ባይዱAE N S I T WSWT D TAW R T R

Fenton试剂在有机废水处理中的研究

Fenton试剂在有机废水处理中的研究

Fenton试剂在有机废水处理中的研究【摘要】:文章阐述了用Fenton试剂处理难降解污染物的现状和进展,简单介绍了其应用及原理。

利用Fenton试剂去除水体中难降解、稳定性强且毒性大的有机污染物。

【关键词】:难降解有机物;Fenton;羟基自由基1894年, 化学家Fenton首次发现有机物在(H2O2)与Fe2+组成的混合溶液中能被迅速氧化,并把这种体系称为标准Fenton试剂,可以将当时很多已知的有机化合物如羧酸、醇、酯类氧化为无机态,氧化效果十分明显[1]。

Fenton试剂是由H2O2和Fe2+混合得到的一种强氧化剂,特别适用于某些难治理的或对生物有毒性的工业废水的处理。

1. Fenton试剂降解有机物的机理Fenton试剂之所以具有非常高的氧化能力,是因为在Fe2+离子的催化作用下H2O2的分解活化能低(34.9 kJ/mol),能够分解产生羟基自基OH·。

同其它一些氧化剂相比,羟基自由基具有更高的氧化电极电位,因而具有很强的氧化性能[2]。

2. Fenton试剂的影响因素Fenton试剂处理难降解有机废水的影响因素根据上述Fenton试剂反应的机理可知, OH·是氧化有机物的有效因子,而[Fe2+]、[H2O2]、[OH]决定了OH·的产量,因而决定了与有机物反应的程度。

影响Fenton试剂处理难降解难氧化有机废水的因素包括pH值、H2O2投加量、催化剂投加量和反应温度[3]等。

2.1 pH值Fenton试剂是在pH是酸性条件下发生作用的,在中性和碱性环境中, Fe2+不能催化H2O2产生OH·。

按照经典的Fenton试剂反应理论,pH值升高不仅抑制了OH·的产生, 而且使溶液中的Fe2+以氢氧化物的形式沉淀而失去催化能力。

当pH 值过低时, 溶液中的H+浓度过高, Fe3+不能顺利地被还原为Fe2+, 催化反应受阻。

即pH值的变化直接影响到Fe2+、Fe3+的络合平衡体系, 从而影响Fenton 试剂的氧化能力。

水中对硝基苯酚去除方法的研究进展

水中对硝基苯酚去除方法的研究进展

广东化工2019年第21期第46卷总第407期•72-水中对硝基苯酚去除方法的研究进展乔政皓,刘辉利,何彩霞,韦春满(桂林理工大学环境科学与工程学院,广西桂林541004)[摘要]对硝基苯酚是环境中一种难溶的有毒有机污染物,近年来这种化合物在许多地表水、地下水和土壤中,甚至饮品、食品中被检出,己对生态系统和人类造成了一定的威胁,因此有必要对其去除治理方法进行研究。

本文综述了对硝基苯酚的来源及危害,总结了目前国内外关于水中对硝基苯酚去除技术的研究进展,并指出了目前研究存在的问题及发展趋势,为今后的研究提供参考。

[关键词]对硝基苯酚:高级氧化法;研究进展[中图分类号]TQ[文献标识码]A[文章编号]1007-1865(2019)21-0072-02Research Progress on the Removal of P-NitrophenolQiao Zhenghao,Liu Huili,He Caixia,Wei Chunman(College of Environmental Science and Engineering,Guilin University of Technology,Guilin541004,China) Abstract:P-nitrophenol is insoluble and toxic organic pollutant in the environment.In recent years,it has been detected in surface waters,groundwater,soil, and even in drinks and foodstufYs.And it has caused serious problems in ecosystems and humans.Therefore,it is necessary to study the removal methods of p-nitrophenol.In this review,we studied the source and hazard of p-nitrophenol.Furthermore,we summarized the current research progress on the removal of p-nitrophenol at home and abroad,and pointed out the problems and development tendency in the current research.We try to provide references for the future research.Keywords:p-nitrophenol;advanced oxidation method:research progress1前百近年来,随着人们生活水平的提高,环境污染问题越来越受到关注,各个国家也加大了治理污染的力度。

UV_Fenton体系氧化降解苯酚废水反应动力学研究

UV_Fenton体系氧化降解苯酚废水反应动力学研究

污水处理UV -Fenton 体系氧化降解苯酚废水反应动力学研究*熊思江1 刘琼玉2 张如月1(1.中钢集团武汉安全环保研究院 武汉430081; 2.江汉大学化学与环境工程学院 武汉430056)摘 要 利用UV-Fenton 高级氧化技术对苯酚废水进行了处理研究。

通过半衰期法对苯酚的反应级数进行了探讨,确定其在UV-Fenton 体系降解过程中的表观反应级数为3/2,并初步建立了苯酚UV-Fenton 降解的动力学模型,并从反应速率系数着手探讨了污染物初始浓度、双氧水加入量、亚铁离子浓度及pH 值对反应降解速率的影响。

关键词 苯酚 UV-Fenton 动力学 光催化氧化Kinetic Studies on Phenol Wastewater Treatment by UV -Fenton OxidationXIO NG Si jiang 1 LIU Qi ong yu 2 Z HA NG Ru yue 1(1.Sinoste el W uhan Safet y and Environmental Protection Researc h Institute Wuhan 430081)Abstract The research of usi ng Photochemical advanced oxidati on proces s (AO Ps)to treat UV-Fenton reaction wastewater is conducted.The reac tion order of phenol is disc ussed by using the half-life method,the apparent reaction order of 3/2in the phenol degradation is de termi ned,meanwhile,the kinetics model of UV-Fenton degradati on is i nitiall y set up.The effect of initial phenol concentrati on,hydrogen peroxi de levels,ferrous ion c oncentration and P H value on the reaction rate of degradation is inves tigated by anal yzi ng the reaction rate coeffi cient as well.Keywords phenol UV-Fenton kinetic s tudies photocatalytic oxidati on酚类化合物毒性强,是我国优先控制的污染物之一,也是美国国家环保局列出的129种优先控制的污染物之一。

Fenton试剂特性及其在水处理中的应用

Fenton试剂特性及其在水处理中的应用

Fenton试剂特性及其在水处理中的应用作者:郑伟来源:《硅谷》2009年第22期[摘要]根据文献资料,概述羟基自由基(HO·)的性质,系统介绍Fenton试剂及其几种类Fenton 试剂H2O2+UV(ultraviolet),H2O2+Fe2++UV,H2O2+Fe2++O2,H2O2+UV+O2和H2O2+Fe2++UV+O2的氧化特性,并对该领域国内外研究动态及在工业废水处理中的应用状况进行较为详细的阐述。

[关键词]Fenton试剂氧化废水处理羟基自由基中图分类号:TV-9文献标识码:A文章编号:1671-7597(2009)1120118-01一、前言在自然界中不仅很多化合物有很强的氧化性,而且当其中几种化合物混合起来或辅以特定物化条件时,往往会发挥更大的效果。

1894年,H.J.H.Fenton发现Fe2+离子通过过氧化氢强烈的促进了苹果酸的氧化,从此以后,众多研究表明过氧化氢与亚铁离子的结合,即Fenton试剂,对于许多有机物都有强烈的氧化作用。

Fenton反应是一种均相的催化氧化反应,它采用过氧化氢为氧化剂,亚铁盐为催化剂,其反应机理为:Fe2++H2O2=Fe3++OHˉ+HO·HO·+RH=H2O+R·R·+Fe3+=R'·+Fe2+R·+H2O=ROH+H+R·+R·=R-R反应中产生的羟基自由基是Fenton试剂强氧化性的主要原因,其具有如下一些性质:1.羟基自由基具有高的氧化电极电位(标准电极电位2.80伏);2. 羟基自由基具有很高的电负性或亲电性;3.其电子亲和能为569.3KJ;4. 容易进攻高电子云密度点;5.这就决定了HO·的进攻具有一定的选择性;6.羟基自由基发生加成反应;7.当有碳碳双键存在时;8.除非被进攻的分子具有高度活泼的碳氢键;9.HO·将发生加成反应。

Fenton试剂在水处理中的应用研究

Fenton试剂在水处理中的应用研究

Fenton试剂在水处理中的应用研究摘要:Fenton试剂在处理难降解有机污染物时具有独特的优势,是一种很有应用前景的废水处理技术。

文章介绍了该技术的发展过程、主要类型及应用现状,并对其在废水处理中的优缺点和发展趋势做出了评述。

关键词:Fenton试剂;水处理;应用Fenton试剂是由H2O2和Fe混合得到的一种强氧化剂,特别适用于某些难治理的或对生物有毒性的工业废水的处理。

因具有反应迅速、温度和压力等反应条件缓和且无二次污染等优点,近30年来,其在工业废水处理中的应用越来越受到国内外的广泛重视。

一、简述Fenton试剂处理效率的影响因素1、pH值因Fe受制于溶液的pH值,所以Fenton试剂只在酸性条件下发生作用,无法在中性和碱性环境中催化H202产生·OH。

研究者普遍认为,氧化废水处理效果较好是pH值在2~4范围内时,在pH=3时效果最佳。

在采用Fenton试剂处理纺织废水时发现,当pH值增加并超过3时,废水中的COD迅速升高,从而得到最优点pH=3。

在此条件下,COD的去除率达到80%。

在催化剂投加与TOC 去除浓度的表现中,当催化剂投加质量浓度较高的情况下,TOC去除浓度的去除效果更好。

2、试剂配比在Fenton反应中,Fe是催化H202产生自由基的必要条件,起催化剂的作用。

在无Fe条件下,H202难于分解产生自由基。

当Fe浓度很低时,自由基的产生量小,产生速度慢,限制整个过程。

当Fe浓度过高时,会将H202还原且被氧化成Fe,增加色度。

研究了不同[Fe]/[ H202 ] 比值对反应的影响。

在[ Fe]/[ H202] = 2 环境中,当有机物不存在时,Fe在几秒内消耗完。

有机物存在时,Fe的消耗大大受到限制(如图2)。

但有机物存在与否,H202都在反应开始的几秒内被完全消耗。

这表明,在高[ Fe]/[ H202比值条件下,消耗H202产生·OH 自由基的过程在几秒内进行完毕。

Fenton试剂_超声波降解对硝基苯胺产物的分析

Fenton试剂_超声波降解对硝基苯胺产物的分析

收稿日期:2003-08-27作者简介:傅厚暾(1949-),男,湖北武汉人,副教授,主要从事仪器分析及计算机在化学中应用的研究。

Fenton 试剂-超声波降解对硝基苯胺产物的分析傅厚暾,赵俐敏,冯 娟,曾 (江汉大学化学与环境工程学院,湖北武汉430056) 摘 要 研究了Fenton 试剂-超声波振荡法降解对硝基苯胺的中间产物和最终产物,分析方法采用气相色质-质谱联用法和离子色谱法。

实验结果表明:对硝基苯胺降解中间产物中有硝基苯、苯酚和对苯醌,最终产物中有硝酸根。

研究了中间产物在降解过程中浓度的变化规律,并对它们的降解机理进行了探讨。

关键词:超声波;降解;对硝基苯胺;中间产物中图分类号:O657.7 文献标识码:A 文章编号:100921777(2004)022*******1 引言对硝基苯胺是一种重要的化工原料,是偶氮染料的中间体,是工业废水中的常见排放物。

对硝基苯胺中硝基为吸电子基,使得苯环上的电子云密度大大下降,使氧化酶的亲电子攻击大大受阻,造成在自然界中较难降解,又具有“三致”作用。

因此,对硝基苯胺的治理研究很有意义。

超声波处理有毒有机污染物技术是20世纪90年代发展起来的一种新的降解处理技术[],是一种清洁、高效的处理方法。

超声波处理技术具有低能耗、小污染和无污染等特点,能加快降解处理的速度。

本文以对硝基苯胺为研究对象,用超声波2Fen 2ton 试剂法进行降解,用气相色谱-质谱联用分析法和离子色谱法检测降解中间产物和最终产物,为研究超声波降解对硝基苯胺的机理提供信息,为进一步提高超声波降解效果提供服务。

理想的降解反应最终产物应该是二氧化碳和水及无机离子,但实际有毒有害有机物的降解往往是不完全的,因此,对降解反应产物进行分析也是评价降解方法的重要环节,有时降解产物的毒性比被降解有机物的毒性还大。

2 机理分析研究表明,超声波震荡之所以能够提高降解反应的速度是由于超声波对溶液的“空化”作用[1,2],使水分子裂解成氢自由基和氢氧根自由基,由于自由基含有未配对电子,性质非常活泼,很容易和其它物质发生反应。

《2024年Fenton试剂处理废水中各影响因子的作用机制》范文

《2024年Fenton试剂处理废水中各影响因子的作用机制》范文

《Fenton试剂处理废水中各影响因子的作用机制》篇一一、引言随着工业化的快速发展,废水处理成为环境保护领域的重要课题。

Fenton试剂作为一种强氧化剂,在废水处理中具有广泛的应用。

本文将重点探讨Fenton试剂处理废水中各影响因子的作用机制,为废水处理提供理论依据。

二、Fenton试剂及其应用Fenton试剂主要由亚铁离子(Fe2+)和过氧化氢(H2O2)组成,通过催化剂的作用,可以产生强氧化性的羟基自由基(·OH),从而对废水中的有机物进行氧化降解。

Fenton试剂具有反应速度快、适用范围广、处理效果好等优点,被广泛应用于废水处理领域。

三、影响Fenton试剂处理效果的因素1. pH值:pH值是影响Fenton试剂处理效果的关键因素。

在酸性条件下,Fenton试剂能产生更多的·OH,从而提高氧化能力。

然而,过低的pH值可能导致亚铁离子沉淀,影响催化剂的活性。

因此,合适的pH值对于提高Fenton试剂的处理效果至关重要。

2. 亚铁离子浓度:亚铁离子作为Fenton试剂的催化剂,其浓度直接影响着·OH的生成量。

适量的亚铁离子可以加速H2O2的分解,产生更多的·OH。

然而,过高的亚铁离子浓度可能导致·OH被消耗,从而降低处理效果。

3. 过氧化氢浓度:过氧化氢是Fenton试剂的主要成分之一,其浓度直接影响着氧化能力的强弱。

适当的过氧化氢浓度可以保证·OH的生成量,过低的浓度可能导致处理效果不佳,而过高的浓度则可能引起副反应,降低处理效率。

4. 反应温度:反应温度对Fenton试剂的处理效果也有一定影响。

适当的温度可以加速反应进程,提高处理效率。

然而,过高的温度可能导致·OH的失活,降低处理效果。

四、各影响因子的作用机制1. pH值的作用机制:在酸性条件下,H+离子可以促进Fe3+与H2O2的反应,生成Fe2+和·OH。

Fenton试剂降解水中酚类物质的研究

Fenton试剂降解水中酚类物质的研究

收稿日期:2003-03-21作者简介:程丽华(1973-),女,工学博士,目前在中国海洋大学做博士后研究工作,主要从事水污染防治技术及工艺研究。

基金项目:黑龙江省自然科学基金资助项目(E 01-06)。

Fen ton 试剂降解水中酚类物质的研究程丽华1,3,黄君礼2,高会旺1(1.中国海洋大学环境科学与工程学院,青岛266003;2.哈尔滨工业大学市政环境工程学院,哈尔滨150090;3.青岛建筑工程学院环境工程系,青岛266033) 摘 要:采用Fen ton 试剂对苯酚、对氯酚、2,4-二氯酚、2,6-二氯酚、间甲酚、对硝基酚和邻硝基酚模拟水样进行处理,并考察了H 2O 2及FeSO 4浓度、pH 、反应温度和反应时间对Fen ton 试剂降解酚类物质的影响,得出Fen ton 试剂降解酚类物质非常有效,当H 2O 2浓度为4mmo l L 、FeSO 4浓度为0.5mmo l L ,在pH 为3,室温条件下反应40m in 则Fen 2ton 试剂对试验所做7种浓度为50mmo l L 的酚类物质的去除率均在98%以上。

为该工艺处理实际含酚废水提供了科学依据。

关键词:酚;Fen ton ;化学氧化;H 2O 2;FeSO 4;pH ;去除率 中图分类号:X 703.1 文献标识码:A 文章编号:1001-2141(2003)10-0018-03 含酚废水是一种来源广、水量大、危害严重的工业废水。

产生含酚废水的工业企业很多,如焦化厂、煤气厂、炼油厂等。

酚类化合物是一种原型质毒物,对一切生活个体都有毒杀作用。

酚能使蛋白质凝固,使细胞失去活力,尤其对神经系统有较大的亲和力。

高浓度的酚能引起急性中毒,甚至死亡;低浓度的酚能引起累积性慢性中毒。

长期饮用被酚污染的水,会引起头晕、贫血、失眠等病症。

含酚废水对给水水源、水生生物的影响颇为严重。

因此防治含酚废水的污染引起了各国的普遍重视。

本文采用Fen ton 试剂对7种酚类物质进行处理,并考察了各种工艺条件对酚类物质去除率的影响情况,以初步确定Fen ton 试剂对酚类物质的处理效果,为该工艺处理酚类物质提出科学依据。

铁粉类FENTON降解对硝基苯酚的研究

铁粉类FENTON降解对硝基苯酚的研究

盐酸和氢氧化钾调节 原水 p H值 , 加 入不 同剂量 的铁 粉和 H : O : , 此过程的发生是要先消耗 水 中 H , 因此近 中性 的原水 处 理效 果
分析 P N P浓度 随时间的变化 , 确定铁粉一类 F E N T O N反应 的影 响 较差。从 图 2中还可以看出在 p H= 2时 , P N P的浓度先 下降后 升

p H=2



p H= 3 p H= 5 p H= 7
[ 2 ]

F E N T O N这种高 级氧 化技 术应用 到水 中对硝 基苯 酚 的降
解已经得到成 功 。但 是 F E N T O N试剂 氧化 成本 过高 , 铁粉 能 将硝基还原成胺基 , 并 产生 F e “, 在反应体系 内加入 H O : 形成类 F E N T O N体系 。本研究主要 以对硝基 苯酚 ( P N P ) 为研究 对象 , 考 察铁粉类 F E N T O N体 系降解 硝基 类有机物的反应参数 。
中图分类号 : T U 9 9 1 . 2 文献标识码 : A
对硝基 苯 酚 ( P N P) 是 医药 、 农 药 和染 料等 精 细化 学 品 中 间 体, 也是重要 的有机合成原料 , 是有 累积效应 的危 险品 , 在 自然 界 中停 留时间较长 , 难于生物降解 , 是我 国水 环境优 先控制 6 8种 污 染 物 之 一… , 也 是 美 国环 境 保 护 局列 出 的优 先 E N T O N 降 解 对 硝 基 苯 酚 的 研 究
石 楠
( 1 . 兰州交通大学环境与市政 工程学院 , 甘肃 兰州 7 3 0 0 0 0; 2 . 济南大学土木建筑学院 , 山东 济 南 2 5 0 0 2 2)

UVfenton处理苯酚废水

UVfenton处理苯酚废水

摘要酚类化合物是美国环境保护署(EPA)列出的129种优先控制的污染物之一,而酚又是一种普遍使用的化工原料,也是许多工业企业生产的副产品。

随着钢铁、炼油、石油化工、塑料、合成纤维等工业的快速发展,含酚废水的种类与数量日益增加,污染范围广、危害性大。

本实验以自制苯酚溶液为模拟废水处理对象,研究紫外光和Fenton试剂联合降解有机物苯酚的氧化能力,利用4-氨基安替比林直接光度法来测定废水中苯酚的含量。

通过实验分析H2O2浓度、Fe2+浓度、pH值、反应时间、紫外光照射时间等因素对UV/Fenton氧化法对降解苯酚的影响。

实验结果确定了在紫外光照射20min前提下的最佳工艺条件:苯酚初始浓度为50mg/L,pH值为3.5,反应时间为60分钟, H2O2的浓度为200mmol/L,Fe2+的浓度为20mmol/L,无论是大于或是小于最佳值浓度均会导致苯酚降解速率的下降。

在此最佳工艺条件下,UV/Fenton对苯酚降解的去除率可达90%以上。

实验结果表明,UV/Fenton氧化法在有机废水处理上是一种非常有效的技术。

关键词紫外光;Fenton试剂;苯酚;催化氧化Study on the Degradation of Phenol compounds by UV/Fenton MethodAbstractPhenolic compounds are one of the U.S. Environmental Protection Agency (EPA) list of 129 priority pollutants, and phenol is a widely used industrial chemicals, is also the product of many industrial production. With the steel, oil refining, petrochemicals, plastics, synthetic fiber industry, the rapid development of the type and quantity of phenolic wastewater increasing pollution a wide range of great danger. In this experiment, self-made solution for the wastewater treatment phenol object of UV and Fenton reagent oxidation of phenol degradation of organic matter, using 4 - Amino antipyrine direct spectrophotometry to determine phenol content. The experiment, the concentration of H2O2, Fe2 + concentration, pH, reaction time, ultraviolet irradiate time on UV / Fenton oxidation on the degradation of phenol. The results confirmed the premise 20min UV irradiation the optimum conditions: the initial phenol concentration 50mg / L, pH = 3.5, reaction time was 60 minutes, H2O2 concentration of 200mmol / L, Fe2+ concentration 20mmol / L, regardless of the value is greater than or less than the optimal concentration of phenol degradation rate will lead to the decline. Under optimum conditions in this, UV / Fenton degradation of phenol removal rate of up to 90%. The results show that, UV / Fenton oxidation treatment of organic waste is a very effective technique.Keywords Ultraviolet;Fenton reagent;Phenol;Catalytic Oxidation目录1 综述 (1)1.1研究的目的及意义 (1)1.2 Fenton试剂 (2)1.2.1 Fenton试剂简介 (2)1.2.2 Fenton试剂的反应机理 (2)1.2.3 Fenton试剂的前景与展望 (3)1.3 UV/F enton法 (3)1.3.1 UV/F enton法简介............................. 错误!未定义书签。

Fenton试剂在催化降解有机污染物中的应用及研究进展[文献综述]

Fenton试剂在催化降解有机污染物中的应用及研究进展[文献综述]

文献综述Fenton试剂在催化降解有机污染物中的应用及研究进展前言高级氧化技术被广泛应用于处理难降解有机工业废水。

与其他高级氧化技术相比,Fenton氧化技术具有快速高效、可产生絮凝、设备简单、成本低、技术要求不高等优点,在工业废水处理研究中应用较为广泛。

Fenton试剂是Fe2+和H2O2的结合,二者反应生成具有高反应活性和很强氧化能力的羟基自由基•OH,•OH 无选择性,能与大多数有机物作用使其降解以至矿化。

随着环境科学技术的发展,近三十年来,Fenton法派生出许多分支,如光–Fenton法、电–Fenton 法、超声–Fenton法等。

因此,从广义上讲可以把除普通Fenton法外,其余的通过H2O2产生羟基自由基处理有机物的技术称为类Fenton试剂法。

虽然Fenton试剂在处理难生物降解或一般化学氧化难以奏效的有机废水时有其它方法无法比拟的优点,但是单独使用Fenton试剂处理废水成本会很高。

所以近年来,Fenton试剂与其它技术(如生物法、絮凝法、吸附法等)联合处理废水也得到了广泛的研究和应用。

从发展历程来看,Fenton法基本上是沿着光化学、电化学以及和其它方法联用的3条路线向前发展的。

1 Fenton试剂氧化机理经典Fenton试剂是法国科学家Fenton[1]于1894 年发现的:在酸性条件下,H2O2在Fe2+离子催化作用下可有效地将酒石酸氧化。

1964年Eisenhouser[2]首次使用Fenton试剂处理苯酚及烷基苯废水,开创了Fenton试剂在环境污染物处理中应用的先例。

经典Fenton试剂在水处理中作用主要包括对有机物氧化和混凝两种作用。

1.1 自由基生成及氧化原理:Fenton试剂之所以具有很强氧化能力,是因为H2O2被Fe2+催化分解生成羟基自由基(•OH),并引发产生更多的其它自由基。

其详细反应机理如下:Fe2+ + H2O2 → Fe3+ + OHˉ+ •OH k1=76 L• (mol /L• s)-1(1) Fe3+ + H2O2 → Fe2+ + HO2• + H+ k2 = 0.002~0.01 L• (mol/ L• s)-1(2) Fe2+ + •OH → Fe3+ + OHˉ k3=3×108 L• (mol/ L• s)-1(3) Fe3+ + HO2•→ Fe2+ +O2+ H+k4﹤2×103 L• (mol /L• s)-1(4)•OH + H2O2→ H2O + HO2•k5=2.7×107 L• (mol /L• s)-1(5) Fe2++ HO2•→ Fe3++ HO2k6=1.2×106 L• (mol /L• s)-1(6) 反应所生成的•OH具有较高的电负性或电子亲和能,它能够通过夺取有机污染物分子中的H 原子、填充未饱和的C—C 键等反应途径使各种有机污染物结构发生碳链断裂而迅速降解。

fenton法降解对硝基苯酚的机理研究

fenton法降解对硝基苯酚的机理研究

Fenton法是一种用于降解有机污染物的技术,通常用于降解废水中的有机污染物。

Fenton 法的机理是利用过氧化氢(H2O2)和铁盐(Fe2+)作为催化剂,将过氧化氢氧化为臭氧(O3),然后将臭氧氧化有机污染物,从而降解有机污染物。

Fenton法降解对硝基苯酚的机理可以概括如下:
1.过氧化氢(H2O2)和铁盐(Fe2+)在催化剂的作用下氧化为臭氧(O3)。

2.臭氧(O3)氧化有机污染物硝基苯酚,将其分解成较小的有机物。

3.过氧化氢(H2O2)和铁盐(Fe2+)在催化剂的作用下再次氧化较小的有机物,将其进一
步分解。

4.这一过程不断重复,直到有机污染物被完全降解为无害物质。

总的来说,Fenton法降解对硝基苯酚的机理是通过过氧化氢(H2O2)和铁盐(Fe2+)氧化有机污染物,将其分解成较小的有机物,再通过过氧化氢(H2O2)和铁盐(Fe2+)将较小的有机物进一步分解,最终将有机污染物降解为无害物质的过程。

Fenton试剂和紫外光_Fenton试剂联合作用处理硝基苯废水

Fenton试剂和紫外光_Fenton试剂联合作用处理硝基苯废水

第20卷第1期1998年1月南 京 化 工 大 学 学 报JOU RNAL O F NAN J I N G UN I V ER S IT YO F CH E M I CAL T ECHNOLO GYV o l.20N o.lJan.1998 Fen ton试剂和紫外光2Fen ton试剂联合作用处理硝基苯废水杨文忠 陈 弋1 王海峻2α(南京化工大学应用化学系,南京,210009)摘 要 通过正交设计试验,研究了Fenton试剂和紫外光(UV)2Fenton试剂联合处理硝基苯废水的最佳工艺条件,并对它们的处理效果进行了比较,发现使用UV2Fenton试剂处理难于降解的硝基苯废水的效果优于单独使用Fenton试剂,紫外光与亚铁离子对过氧化氢的分解具有协同作用。

关键词 紫外光 Fenton试剂 硝基苯废水 废水处理中图分类号 X783 硝基苯是工业废水中典型的有机污染物,一般为无色至淡黄色油状液体,具有苦杏仁味[1],是一种难化学氧化、难生物降解的、有毒的有机污染物,用常规的废水处理方法很难使之净化[2]。

Fen ton(H2O2 Fe2+)是一种氧化性很强的氧化剂,可以使许多难氧化的有机物降解而被除去[2]。

E isenhauer首次使用它研究处理苯酚废水[3]和烷基苯废水[4],之后,Fen ton试剂在工业废水处理中的应用研究越来越受到重视[5~7]。

相对来说,过氧化氢自身的氧化能力并不太强,但是它在亚铁离子催化分解下能发挥出更强的氧化能力,在短时间将有机物氧化分解。

值得重视的是,将紫外光(UV)引入Fen ton试剂可大大地提高Fen ton试剂的氧化性能,Koubek[8]和A ndrew s[9]采用UV2H2O2处理有机污染物和TN T废水均取得了良好的效果。

本文主要探讨Fen ton试剂单独作用和紫外光2Fen ton试剂联合作用处理硝基苯废水的效果及作用机理。

1 机 理1.1 Fen ton试剂反应机理过氧化氢在碱性条件下是不稳定的,很容易分解,而在酸性条件下是稳定的,几乎不显示反应性[10],但在与亚铁离子共存的条件下,具有极强的氧化能力,亚铁离子作为催化剂使过氧化氢分解产生羟基自由基[11]:Fe2++H2O2→Fe3++OH-+·OH(1)Fe3++H2O2→Fe2++·HO2+H+(2)·OH+H2O2→H2O+·HO2(3)·HO2→·O2-+H+(4)·O2-+H2O2→O2+·OH+OH-(5)羟基自由基比其它常用的氧化剂(如M nO4-,C l O2)具有更高的电极电势:·HO+H+=H2O E o=2.80V(6)所以,·OH、·HO2等自由基可与废水中的有机物发生反应,使其分解[11]:·OH+RH→R·+H2O(7) R·+O2→ROO·→ROOH→分解产物+·OH(8) 1.2 紫外光2Fen ton试剂联合作用机理铁离子催化分解过氧化氢主要通过Fe2+、Fe3+之间的相互转化而进行。

浅析采用UVFenton法吸收处理硝基苯废气.doc

浅析采用UVFenton法吸收处理硝基苯废气.doc

摘要室内空气屮可挥发有机污染物对人体的危害严重影像了人们的生活质量和身体健谈,Fenton试剂法处理有机污水的研究较早。

在液态吋促进化学反应能够极大的提高低溶解性挥发性有机化合物(VOC S)的吸收率,进而提高去除率。

木设计提出采用UV/Fenton法吸收处理硝基苯废气。

硝基苯中的硝基为强钝化基,须在较强的条件不硝基苯才能发生亲电取代发应,生成间位产物,生物降解很难。

Fenton 试剂在紫外灯的照射下,能够产生较多的DH自由基,使硝基苯被氧化去除,去除效率高。

关键词:有机废气,吸收塔,UV/Fenton法,硝基苯废气AbstractIt was fairly earlier to treat organic wastewater with Fenton as a reagent. Promotion of chemical reactions at the liquid phase can significantly improve the rate of low-solubility volatile organic compounds(VOCs),and then increase the efficency of removal.In this design, the treatment of nitrobenzene with UV/Fenton is proposed . The nitro of nitrobenzene is passivation,to be stronger in terms, nitrobenzene can happen electrophilic substitution, m-generation is producted,nitrobenzene biodegradable is difficult. Fenton in ultraviolet light irradiation, can produce more OH radicals,nitrobenzene is oxidation removal,with high removal efficiency.Key words : Organic emissions,Absorption tower,UV/Fenton, Nitrobenzene1雜 (1)1.1硝基苯的特性 (1)1.2硝基苯对人体健康的危害 (1)1.3硝基苯的毒理学资料及环境行为 (1)1.4硝基苯有机废气处理的必要性 (2)2常用的净化方法 (3)2.1勳雜 (3)2.2催化氧化 (4)2.3炭吸附法 (5)2.4冷凝法 (8)2.5膜分离技术 (19)2.6变压吸附技术 (10)2.7生物处理技术 (10)2.8高压脉冲电晕法 (10)2.9叟氧分角〒'法(Ozonolysis Method) (11)2.10光分角¥法(Photeolysis Method) (11)2.11离子体分角早法(Plasma Decomposition) (12)3UV/Fenton净化处理法 (13)3.1UV/Fenton法氧化机理 (13)4设计资料 (15)4.1硝基苯废气的气量和组成 (15)4.2设计依据与原则 (15)4.3洲WJ (15)4.4设计范H (15)设计目标 (16)5UV/Fenton净化处理工艺设计 (17)5.112 賴 (17)5.2工艺设计计算 (18)5.2.1吸收塔尺寸的确定 (18)5.2.2喷淋量的确定 (19)5.2.3 吸收塔附件的选择 (19)5.2.4吸收塔总压降 (22)5.2.5 管网设计 (22)5.2.6风机及配套电机的选择 (27)1997.4 ........................................................................................................................... 工程投资. (32)1997.5 ........................................................................................................................... 运行费用. (33)4.5成本概算有关单价 (33)4.5运行成本概算 (33)X (34)SC i射 (36)1绪论1.1硝基苯的特性硝基苯为淡黄色油状液体,有苦杏仁味,具有挥发性,能随水蒸汽同时挥发,可溶于醇,微溶于水。

Fenton试剂氧化对硝基酚中氧化还原电位的变化规律

Fenton试剂氧化对硝基酚中氧化还原电位的变化规律

Fenton试剂氧化对硝基酚中氧化还原电位的变化规律赵云;王丽萍;何士龙;侯梅锋;陈雪梅;张莉【期刊名称】《环境污染与防治》【年(卷),期】2011(033)004【摘要】考察了Fenton试剂氧化对硝基苯酚(PNP)过程中氧化还原电位(ORP)的变化规律.结果表明:(1)当pH为3、H2O2投加量为3 mmol/L、Fe2+投加量为0.3 mmol/L时,废水中PNP在5.0 min时降到5 mg/L左右,去除率达95%;废水可生化性得到有效改善(BOD5/COD由最初的0.073升至0.390).(2)ORP反应了整个Fenton体系中的氧化还原状态,而整个体系中主要的氧化还原物质是Fe2+、·OH、H2O2、0Fe3+以及氢醌等,ORP变化规律直接反映了哪种氧化还原物质的变化尚未明确,需进一步验证.(3)ORP的变化直接反映了Fe2+/Fe3+的形态变化.(4)利用ORP的变化可以反映Fenton试剂降解有机物的起始、快速降解及降解结束的稳定阶段.【总页数】5页(P58-61,65)【作者】赵云;王丽萍;何士龙;侯梅锋;陈雪梅;张莉【作者单位】中国矿业大学环境与测绘学院,江苏徐州221008;江苏省资源环境信息工程重点实验室,江苏徐州221008;中国科学院生态环境研究中心,环境水质学国家重点实验室,北京100085;中国矿业大学环境与测绘学院,江苏徐州221008;江苏省资源环境信息工程重点实验室,江苏徐州221008;中国矿业大学环境与测绘学院,江苏徐州221008;江苏省资源环境信息工程重点实验室,江苏徐州221008;中国科学院生态环境研究中心,环境水质学国家重点实验室,北京100085;中国矿业大学环境与测绘学院,江苏徐州221008;江苏省资源环境信息工程重点实验室,江苏徐州221008;中国矿业大学环境与测绘学院,江苏徐州221008;江苏省资源环境信息工程重点实验室,江苏徐州221008;中国矿业大学环境与测绘学院,江苏徐州221008;江苏省资源环境信息工程重点实验室,江苏徐州221008【正文语种】中文【相关文献】1.Fenton反应中氧化还原电势的变化规律 [J], 高迎新;张昱2.Fenton试剂氧化法在工业废水处理中的应用研究 [J], 孟克其其格3.Fenton和类Fenton氧化反应在化学试剂生产过程产生的影响及应对措施 [J], 肖克强;周红艳4.泡沫镍和泡沫铜阴极电类Fenton氧化降解对硝基酚的比较 [J], 汤茜;孙娟;任小蕾;杨春维;王栋5.氧化还原电位指示Fenton反应过程的研究 [J], 邹红;王丽萍;余美维因版权原因,仅展示原文概要,查看原文内容请购买。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

2005 年 8 月 Journal of Chemical Engineering of Chinese Universities Aug. 2005 文章编号:1003-9015(2005)04-0567-04US/Fenton试剂法在水体系中降解对硝基苯酚的研究许春建, 王卉, 吕东来, 蒋建华, 周明(天津大学化学工程研究所, 天津 300072)摘要:将超声波(US)/Fenton试剂法有机地结合起来,用于对硝基苯酚(p-NP)的降解实验,实验中发现US/Fenton试剂法降解p-NP具有明显的协同效应,结果优于Fenton试剂法与US法的简单加合。

全面考察了初始pH值、H2O2浓度和Fe2+浓度等因素对US/Fenton试剂法降解p-NP过程的影响。

结果表明,在实验范围内,溶液的初始pH值越小,分子态的p-NP比例越大,越易于进行反应;同时H2O2的利用率越高,US/Fenton试剂法对p-NP的降解效果越好。

H2O2和 Fe2+浓度越高,·OH自由基的数量越多,·OH 自由基有利于p-NP的降解,因此US/Fenton试剂法对p-NP的降解效果越好。

关键词:US/Fenton试剂法;p-NP;协同效应;超声波;降解中图分类号:X703.1文献标识码:ADegradation of p-Nitrophenol in Water by Ultrasound/Fenton Reagent MethodXU Chun-jian, WANG Hui, LU Dong-lai, JIANG Jian-hua, ZHOU Ming (Chemical Engineering Research Center, Tianjin University, Tianjin 300072, China)Abstract: The application of ultrasound(US)/Fenton reagent method to the degradation of p-nitrophenol (p-NP) in water was studied. It is found that the degradation of p-nitrophenol by US/Fenton reagent method had an obvious synergistic effect. The result is better than the simple summation of Fenton reagent method and US method. The influences of initial pH value in solution, concentration of H2O2 and Fe2+ on the experimental results were studied in detail. Since the pH value will effect the p-NP existing state (in ionic state or in molecular state), with lower pH value, the p-NP will exist in a higher proportion of molecular state which is easier to be degraded by the ultrasonic cavitation. Moreover, under lower pH, the H2O2 becomes more effective. Therefore the experimental results show that the lower initial pH value will have better p-NP degradation. In addition, since the free radical ⋅OH does favour the p-NP degradation, increasing the H2O2 and Fe2+ concentration will increase the number of free radical ⋅OH, so at the same time it will make the p-NP degradation more effective.Key words: US/Fenton reagent method; p-Nitrophenol; synergistic effect; ultrasonic; degradation1引言超声波(ultrasound)降解废水中的化学污染物,尤其是某些难降解的有机物,是近年来发展的一项新颖、清洁的水处理技术。

它是指利用超声辐射所产生的空化效应,将有机大分子化合物化学分解为环境可以接受的小分子化合物[1]。

Fenton(H2O2/Fe2+)试剂具有较强的氧化性,常用于处理某些难以生物降解的有机废水,是目前水处理界研究热点之一[2]。

目前,多种氧化技术联合使用是水处理研究领域中的一个发展方向。

已有一些学者成功地将紫外光与Fenton试剂相结合(UV/Fenton试剂法)用于降解废水中的某些有毒有机物[3]。

而很少有将超声波和Fenton试剂法有机的结合起来(US/Fenton试剂法)用于废水处理的报道。

因此,本文研究了US/Fenton试剂法对含有对硝基苯酚(p-NP)的废水的处理效果,并考察了初始pH值、H2O2浓度和Fe2+浓度等因素对实验结果的影响。

收稿日期:2003-10-10;修订日期:2004-08-17。

作者简介:许春建(1965-),男,天津大学副研究员,博士。

通讯联系人:许春建,E-mail:cjxu@C o n c e n t r a t i o n o f p -N P / m g ⋅L −1图2 3种水处理方法的比较实验Fig.2 Comparison of three kinds of treating method [p -NP]=100mL ⋅L −1, pH=3, V =100mL, T =25℃,[Fe 2+]=10mg ⋅L −1, [H 2O 2]=200mg ⋅L −1, D =1.76W ⋅mL −146810121416182022T im e t / m in C o n c e n t r a t i o n o f H 2O 2 / m g ⋅L−1图3 不同作用条件下H 2O 2的分解情况Fig.3 Decomposition of H 2O 2 in the different situations[H 2O 2]=200 mg ⋅L −1, [Fe 2+]=10 mg ⋅L −1, pH=3,V =100mL, T =25℃, D =1.76W ⋅mL -1Time / minTime / min246810122 实 验实验装置如图1所示,主体为小型探头式间歇声化学反应器,超声波以连续辐射的方式加入。

探头垂直浸入溶液中,已有研究表明探头浸入过深不利于声化学反应的进行[4],在本实验中浸入深度选择在1cm 左右。

反应容器为容积250mL 的玻璃烧杯,容器上部敞开,这样反应溶液中溶解的空气可以与外部空气达到动态平衡。

由于超声发生器本身电-声能转化率低于50%,其中一部分电能将转化为热能,尤其当作用时间较长时,对反应液体温度的影响很大。

不利于声化学反应的研究,因此实验中采用恒温水浴来控制温度。

由于反应容器体积较小,在超声波作用下,容器内的反应液体混合良好,在超声辐射实验时未加搅拌装置。

在单独进行Fenton 试剂法降解实验时,将图1中的超声探头改为电动搅拌器。

实验采用紫外分光光度计测定p -NP 在溶液中的浓度,测定下限可达0.1mg ⋅L −1。

所用波长λ为:酸性条件(pH =3~4),λ=317nm ;碱性条件(pH=11),λ=400nm 。

实验测定结果表明,在两个波长下的测定结果相差小于5%,说明测定方法可靠。

同时实验中加入的H 2O 2、NaHCO 3和Fenton 等试剂在λ=317nm ,400nm 两个波长条件下均无吸收峰,不会影响p -NP 的测定结果。

实验采用草酸钛钾比色法测定溶液中的H 2O 2浓度,所用的波长λ=400nm ,除F −外,通常不受其他离子的干扰。

3 实验结果及讨论3.1 US/Fenton 试剂法的协同效应图2比较了分别在超声波(US)、Fenton 试剂和US/Fenton 试剂法3种方法作用下,反应溶液中p -NP 浓度随时间变化。

从图中可以看出:在相同时间条件下,采用US/Fenton 试剂法所得的实验结果明显优于Fenton 试剂法和US 法。

同时US/Fenton 试剂法也优于这两种方法的简单加合(即曲线US+Fenton 所代表的结果),具有明显的协同效应。

采用US/Fenton 法在t =120min 时,p -NP 的降解率可达89%。

US/Fenton 试剂法具有明显的协同效应可解释为(1)超声波可加快Fe 3+向Fe 2+的转化速度,生成的Fe 2+可进一步起到催化分解H 2O 2的作用,生成更多的·OH 自由基,这些自由基一方面可以与p -NP 直接发生氧化反应,同时也可以与p -NP 的苯环发生加成反应,破坏苯环,形成脂肪族化合物。

为了证实这一假设,本文设计了分别在Fe 2+和US/Fe 2+作用下,H 2O 2的分解实验,实验结果如图3所示。

从图中可以看出,在超声波和Fe 2+共同作用下,H 2O 2的分解率得到明显的提高。

如在t =120min 时,仅在图1 实验装置图Fig.1 The experimental apparatus1.ultrasonic generator2.energy convertor3.probe4. solution5.thermostat6. thermometer第19卷第4期 许春建等: US/Fenton 试剂法在水体系中降解对硝基苯酚的研究 56924681012C o n c e n t r a t i o n o f p -N P /m g ⋅L −1Time t / min图4 溶液初始pH 对US/Fenton 法实验结果的影响Fig.4 The effect of preliminary pH value [p -NP]=100mg ⋅L −1, pH=3,5,7 respectively, V =100mL T =25℃, D =1.76W ⋅mL -1, [Fe 2+] =10 mg ⋅L −1, [H 2O 2] =200 mg ⋅L −1123456789101112C o n c e n t r a t i o n o f ρ-N P / m g ⋅L −1Time t / min图5 H 2O 2浓度对US/Fenton 试剂法实验结果的影响Fig.5 The effect of the H 2O 2 concentration [p -NP] =100 mg ⋅L −1, pH =3, V =100mL T =25℃, D =1.76W ⋅mL −1, [Fe 2+] =10 mg ⋅L −1, [H 2O 2] =50,100,200,500 mg ⋅L −1 respectivelyFe 2+作用下,H 2O 2的分解率约为60%;而在超声波和Fe 2+共同作用条件下,H 2O 2的分解率可达76%。

相关文档
最新文档