barely touches the surface and that the dial is adjusted to zero
before each reading.Clean the tip of the cone with acetone or
methyl ethyl ketone (MEK)prior to each reading.
9.Report
9.1Average the ten readings on the two specimens.If none
of the readings vary more than 15%from the average,report
the average as well as the individual readings.If one or two
readings vary more than 15%from the average,discard those
readings and report the remaining readings and their average.If three or more readings are outside the 15%limit,repeat the test.10.Precision and Bias 10.1There is no precision or bias statement for this test method.The precision statement for Test Method D 2451can be used as a guide.11.Keywords 11.1glazing compound;set;wood sash
The American Society for Testing and Materials takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this ers of this standard are expressly advised that determination of the validity of any such patent rights,and the risk of infringement of such rights,are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and if not revised,either reapproved or withdrawn.Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM Headquarters.Your comments will receive careful consideration at a meeting of the responsible technical committee,which you may attend.If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards,100Barr Harbor Drive,West Conshohocken,PA
19428.。