Rosette A
Rosette B
Figure 1 : Strain gauge locations on the GN Septimus PCBA 28-02944-B
LA-09-0035
Preparation:
The procedures for the strain gage attachment are as follows:
a. Surface is prepared using 600 and 1000 grit silicon carbide paper.
b. M-prep Conditioner A and Neutralizer are applied to remove residue.
c. Rosette strain gages are attached on the PCB board surface near component.
d. The set-up is connected to the measurement system,Vishay 6100 system, and data
is recorded every 0.002(500Hz).
Results & Discussions:
•Figure 3 shows strain measurement of GN Septimus PCBA 28-02944-B at the FCT station. Data is acquired during the testing at this station.
•Result of strain measurement is shown in the table 1, and Figure 4 shows the result of measurement refered from acceptable guideline. Table 2 shows the result of measurement refered from time history measurement data.
•Graph plot of result data as compared IPC guideline is shown in the Figure 4.
Figure 3: Strain measurement at the FCT station.
LA-09-0035
Figure 4 : Graph plot of Septimus PCBA 28-02944-B test result data is compared IPC guideline
Result :
The strain measurement has been completed and the result of the FCT fixture modified by TE was acceptable .
Date: Feb-19-2009 Date: Feb-19-2009
Remark:
1. QA laboratory doesn’t allow any alteration or modification of this report, or any part of
this report, without prior formal written permission from QA Senior Manager Asia.
2. Experimental results are only valid for the specimens tested.
3.This report is meant for the purpose of internal evaluation only and shall not be used,
neither in whole nor in parts, as any form of standards and/or evidences in any legal
proceedings.。