HIF3HB-10DB-2.54DSB中文资料
布希安全系统产品说明书
Connector
Screw terminal block
* Technical performance data acc. to IEC 60268-5 Mechanical
Dimensions (L x Dmax)
499 x 490 mm (20 x 19.6 in)
Weight
4.5 kg (9.9 lb)
LBC 3484/00 Electrical*
Maximum power
75 W
Rated power
50 / 25 / 12.5 W
Sound pressure level at 50 W / 1 W (1 kHz, 1 m)
127 dB / 110 dB (SPL)
Effective frequency range (-10 dB)
Color
Light gray (RAL 7035)
Cable diameter Environmental
6 mm to 12 mm (0.24 in to 0.47 in)
Operating temperature
-25 ºC to +55 ºC (-13 ºF to +131 ºF)
Storage and transport temperature
CE-label LBC3482/00
CE-label LBC3483/00
Bosch Security Systems B.V.
Installation note
2016.5 | V1.01 |
Bosch Security Systems B.V. Torenallee 49 5617 BA Eindhoven Netherlands © Bosch Security Systems B.V., 2016
HB54R5128KN-10B中文资料
Pin name VSS DQ23 DQ28 VCC DQ29 DM3 VSS DQ30 DQ31 VCC NC NC VSS NC NC VCC NC NC VSS VSS VCC VCC CKE0 NC A11
Data Sheet E0189H40 (Ver. 4.0)
2
HB54R5128KN-A75B/B75B/10B
Features
• 200-pin socket type package (dual lead out) Outline: 67.6mm (Length) × 31.75mm (Height) × 3.80mm (Thickness) Lead pitch: 0.6mm • 2.5V power supply (VCC) • SSTL-2 interface for all inputs and outputs • Clock frequency: 133 MHz (max) (-A75B/B75B) : 100 MHz (max) (-10B) • Data inputs, outputs and DM are synchronized with DQS • 4 banks can operate simultaneously and independently (Component) • Burst read/write operation • Programmable burst length: 2, 4, 8 Burst read stop capability • Programmable burst sequence Sequential Interleave • Start addressing capability Even and Odd • Programmable /CAS latency (CL): 2, 2.5 • 8192 refresh cycles: 7.8µs (8192row/64ms) • 2 variations of refresh Auto refresh Self refresh
哈纳刀形液滴传感器水浊度计(HI 93703-11)用户手册说明书
2Dear Customer,Thank you for choosing a Hanna product.Please read this instruction manual carefully before using the instrument.This manual will provide you with the necessary information for the correct use of the instrument.If you need additional technical information, do not hesitate to e-mail us at ******************directives.Preliminary Examination ............................3General Description....................................3Principle of Operation .................................5Functional Description................................6Specifications ............................................7Operational Guide ......................................8Measurement Procedure.......................8Log-on-demand ...................................11Cleaning Logged Data .........................11Viewing Logged Data ..........................12Viewing and setting Date and Time .....12Error Codes.........................................13Ensure Accurate Measurements.............14Sources of Interference.......................15Calibration................................................16Calibration Procedure..........................16Viewing Calibration Date .....................18Ensure Accurate Calibration................18Standard Suspension..........................19Battery Replacement ...............................20PC Connection.........................................21Accessories.............................................22Warranty.. (23)23Recommendations for UsersBefore using this product, make sure that it is entirely suitable for the environment in which it is used.Operation of this instrument in residential area could cause unacceptable interferences to radio and TV equipments, requiring the operator to take all necessary steps to correct interferences.Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance.To avoid electrical shock, do not use this instrument when voltages at the measurement surface exceed 24 Vac or 60 Vdc.To avoid damages or burns, do not perform any measurement in microwaveovens.All Hanna Instruments meters are warranted for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instruc-tions. This warranty is limited to repair or replacement free of charge. Damages due to accidents, misuse, tampering or lack of pre-scribed maintenance are not covered.If service is required, contact the dealer from whom you purchased the instrument. If under warranty, report the model number, date of purchase, serial number and the nature of the failure. First obtain a Returned Goods Authori-zation number from the Customer Service de-partment, then return the instrument with the Authorization # included along with shipment costs prepaid. If the repair is not covered by the warranty, you will be notified of the charges.When shipping any instrument, make sure it is properly packaged for complete protection.All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner.3Remove the instrument from the packing material and examine it to make sure that no damage has occurred during shipping. If there is any damage,notify your Dealer.HI 93703-11 is supplied complete with:•Glass cuvet with cap •Batteries (4 x 1.5V AA)•Instruction manualNote : Save all packing material until you are sure that the instrument functions correctly. Any defective item must be returned in its original packaging with the supplied accessories.With HI 93703-11 turbidity measurements can be performed with high precision in the field as well as in the laboratory. HI93703-11 turbidity meter is a microprocessor-based instrument used to determine the turbidity of water and waste-water. The meter covers a 0-1000 FTU range in two scales: 0.00 to 50.00 FTU and 50to 1000 FTU. The autoranging feature of the instrument sets the appropriate range for the measurement.HI 93703-11 also includes a real-time clock and log-on-demand capability. The PC communication is made through a serial port of your computer and the 5-pin socket on the meter.Note:HI 93703-11 has been designedaccording to the ISO 7027 International Standard, consequently the turbidity measurement units are expressed in FTU (Formazine Turbidity Unit). FTU is identical to the other internationally recognized unit: NTU (NephelometricTurbidity Unit).22HI 731318Tissue for wiping cuvets (4pcs)HI 731321Spare glass cuvet (4pcs)HI 731313Maintenance kit: rugged carrying case including HI 93703-0 and HI 93703-10calibration solutions, HI 93703-50 cuvet cleaning solution, 1tissue for wiping cuvets and 2cuvetsHI 93703-0AMCO-AEPA-1 @0 FTU*calibration solution, 30 mL HI 93703-05AMCO-AEPA-1 @500 FTU*calibration solution, 30 mL HI 93703-10AMCO-AEPA-1 @10 FTU*calibration solution, 30 mL HI 93703-50Cuvet cleaning solution, 230mLHI 92000Windows ® compatible software HI 920011Serial cable for PC connection (5 to 9-pin)* 1 FTU = 1 NTU4The meter is housed in a rugged and lightweight case, with an easy-to-read LCD.To save battery-life, the instrument is equipped with an automatic shut-off feature which is activated after 5-minutes of non-use. This fea-ture is disabled when the meter is connected to the serial port of the computer.All operations can be carried out with only five keys and troubleshooting functions can be performed with displayed error code guides.A positive-locking system guarantees that the cuvet is firmly placed in the cell.The keypad is water-resistant and can be wiped with a moist cloth for quick cleanups.Two or three point calibration (0,10, 500 FTU*)can be easily performed using available stan-dards, and the last calibration date is auto-matically stored for future retrivial.We have chosen 10 FTU * as the standard calibration point because it best fits the water turbidity measurements in different applications, from drinking water to waste-water treatment.HANNA instruments ® uses the primary stan-dard AMCO-AEPA-1 to avoid all formazine-related problems. Formazine is a toxic, un-stable substance, which requires particular care:its standards have to be prepared only a few minutes before performing the calibration, and cannot be reused because of their short life.HANNA instruments ® standards are extremely stable, can be reused, and last up to six months, if free from contamination.HI 93703-11 can be used with both standards.* 1 FTU = 1 NTU21Battery replacement must only take place in a safe area and using 1.5V AA alkaline batteries.To install or replace the batteries, turn the unit off and remove the battery compartment cover on the raer of the meter.Insert the new batteries while paying attention to the polarity.After the batteries have been installed, close the battery cover and make sure the gasket is in place before tightening the 2 screws, to ensure a watertight seal.POTSTo communicate with the instrument through the HI 92000 software, use the HI 920011 cable (optional) to connect a serial port of your com-puter to the 5 pin connector of the meter.When connected the meter will maintain full functionality, being able to perform a data trans-fer while the meter is being operated.Notes :• Serial communication is not allowed when the meter is being calibrated.• The auto shut-off feature is also disabled when the meter is connected to a computer.5IR LEDCUVETLIGHT DETECTORLIGHT* 1 FTU = 1 NTUHI 93703-11 has been designed to perform measurements according to the ISO 7027 In-ternational Standard.The instrument functions by passing a beam of infrared light through a vial containing the sample being measured.A sensor, positioned at 90° with respect to the direction of light, detects the amount of light scattered by the undissolved particles present in the sample. The microprocessor converts such readings into FTU* values.As noted above, FTU unit is equal to the NTU unit. However, there are other known measure-ment units for turbidity: Jackson Turbidity Unit (JTU) based on the old method of Jackson's candle, and Silica Unit (mg /L of SiO 2). For your reference the conversion table between these measurement units is shown below:JTUFTU/NTUSiO 2 (mg/L)JTU119 2.5FTU/NTU 0.05310.13SiO 2 (mg /L)0.47.5120All components have been selected to mini-mize current drain without compromising func-tionality. In order to minimize the battery con-sumption, the meter is equipped with an auto-shut off function which switches the meter off after 5 minutes of non-use.The four 1.5V batteries guarantee 60 hours of working life (or 900 measurements).In order to obtain accurate measurements, the battery level is monitored every time the meter is switched on.In addition, a "LO BAT " indication will appear on the lower right corner of the display when the batteries are weak (<10%). All four batteries need to be replaced.When the batteries are too weak to ensure reliable measurements, the message 0% LO BAT appears for a few seconds, and then the meter will automatically switch itself off. Re-place the batteries immediately.61)Measurement cell2)LCD (Liquid Crystal Display)3)ON/OFF/CLR key, to turn the meter ON and OFF, and to clear log memory4)GLP/CAL key, to display last calibration date & time, and to enter calibration mode 5)STO/VIEW key, to store sample after read-ing, and to view log memory6)READ/DATE key, to perform measure-ments, and to display (toggle) current date/time7)ALT key, to activate the second functions (second function keys in orange)8)RS232 connector (5 pin)19* 1 FTU = 1 NTUSTANDARD SUSPENSIONPresently, there are only two recognized pri-mary standards: AMCO-AEPA-1 and formazine.Hanna supplies HI 93703-11 with the AMCO-AEPA-1 which has a much longer shelf life at all concentrations (approx. six months, if free from contamination). In addition, no special handling or disposal is required and a much higher stability of suspended particles has been ob-served.On the other hand, formazine is a toxic sub-stance, generated by a known carcinogen, with poor stability (particles flocculate and settle quickly). Lower concentrations change value within a few days or hours after dilution.The consistency of HI 93703-11 readings by using both standards has been separately es-tablished by Advanced Polymer Systems and Hanna Instruments.Additional documentation about the formazine standard and more complex calibration proce-dures is available upon request.•All glassware that comes into contact with standards should be maintained clean. Wash with the HI 93703-50 cleaning solution and rinse with HI 93703-0 or turbidity free water.•Rinse the vial twice with 5 ml of the liquid to be tested. This removes the effect of any previous liquid and any dust or foreign ob-jects that may be present inside. Gently pour the liquid down the side of the vial to reduce air bubbles (no mixing is required when HI 93703-0 and HI 93703-10 AMCO-AEPA-1standards are used).•Before inserting the vial into the instrument,wipe it with HI93703-70 or a soft, lint-free tissue. Handle vials so that no fingerprints can get on the areas where light passes (approx. bottom 2cm/1").7* 1 FTU = 1 NTURange 0.00 to 50.00 FTU *50 to 1000 FTU *Resolution 0.01 and 1 FTU *Accuracy±0.5 FTU* or±5% of reading (whichever is greater)Typical EMC Deviation ±2% FS Calibration 3 point (0, 10 and 500 FTU*)Light SourceInfrared LED Light Source Life Life of the instrument Light Detector Silicon photocellData Logging199 measurements, on-demand PC Connection Through serial port,using HI 920011 connection cable and HI 92000 Windows ® compatible software Battery Type4 x 1.5V AA alkaline batteries Battery Life Approx. 60 hours of continuous useor 900 measurementsAuto-offAfter 5 minutes of non-use Environment 0 to 50°C (32 to 122°F);RH max 95% non-condensingDimensions 220 x 82 x 66 mm (8.7 x 3.2 x 2.6")Weight510 g (1.1 lb.)18•After approximately 30 seconds the LCD will display "----".Now the instrument is calibrated and ready for use.NOTE: If "ERR1" is displayed, the calibra-tion data is maintained.VIEWING CALIBRATION DATE To display the last cali-bration time and date,press the GLP button to toggle through the date and time. If the display shows "FS", the instru-ment has factory calibra-tion settings loaded and no date will be displayed.VIEWING FIRMWARE VERSIONTo display the firmware version press and hold the ON/OFF key for approx. ten seconds (when turning the meter on).The firmware version will be displayedENSURE ACCURATE CALIBRATIONThe procedure below should be carefully fol-lowed during testing and calibration:8To prepare the instrument for taking measurements, first install the batteries (see Battery Replacement section on page 20) and then turn the instrument on.To maximize battery-life, the display is automatically switched off after 5-minutes of non-use. To reactivate the display, simply press the ON/OFF key.MEASUREMENT PROCEDURE:•Turn the meter on by pressing the ON/OFF key.•The meter will carry out a self-test display-ing a full set of figures.•The meter will carry out a battery test show-ing in percentage the battery life left.•When the LCD dis-plays “----” the meter is ready to measure.•Fill a clean cuvet up to one quar-ter inch (0.5cm) from its rim with the thoroughly agitated sample.•Allow sufficient time for bubbles to escape before securing the cap.Note:do not overtighten the cap.17•If "ERR1" appearson the LCD, please check the standard solution.•After approximately 30 seconds the meter will display 10.00, prompting the user to place the 10.00 FTU standard solution in the cuvet holder.•Place the 10.00 FTUstandard in the holder press CAL, SIP and CL will start blinking•After approximately30 seconds the meterwill display 500, asking the user to place the 500 FTU buffer solution in the cuvetholder.NOTE: At this point theuser can save the two point calibration setup by pressing ALT & CAL buttons,To perform a three point calibration, place the 500FTU standard solution in the cuvet holder.•Press CAL, SIP and CL will start blinking9NOTE: Wipe the cuvet thoroughly with a lint-free tissue (HI 93703-70) before in-serting into the measurement cell.The cuvet must be completely free of fingerprints and other oil or dirt, par-2 cm/1").•cu re ly int o t groove.•The mark on the cuvet cap should point towards the LCD.•onds.16To check the date of last calibration, simply press the GLP/CAL key. Press again to toggle between date and time.To make sure that the meter is calibrated, take a measure of a standard solution.The instrument can be calibrated at two or three points and a monthly calibration is recom-mended.CALIBRATION PROCEDURE •Turn the meter on and wait for the display to show "----".•Press the ALT & CALbuttons together. The "CAL" message will blink on the display 3times. The meter then enters the calibrationmode, displaying "0.00cl" and prompting the user to insert the 0.00FTU standard.••Press CAL, SIP and CL will start blinking10* 1 FTU = 1 NTU•Even though HI93703-11 covers a very wide range of turbidity values, for very accurate measurements of samples ex-ceeding 40FTU*, Standard Methods re-quire dilution. In such cases, the correct amount of HI 93703-0 or turbidity-free water to be added to the sample can be calculated as follows:Vos = 3000 / T where:Vos = volume of sample (mL) to becombined with HI 93703-0 to obtain the final volume of 100mL.T =HI 93703 reading (exceeding40FTU*)E.g.:HI 93703 reading = 200 FTU *3000 / 200 = 15 mL (Vos)15 mL (Vos)+85 mL (HI93703-0) = 100 mL At this point, take a sample of this solution and measure its turbidity.The correct turbidity value of the original sample will be:T n x 100 mL / Vos = T awhere:T n = new HI 93703 readingT a =actual turbidity value of the originalsample E.g.If T n = 27 FTU *T a = 27 FTU *x100 mL / 15 mL = 180 FTU *NOTE: Any sample taken above 1000 FTU will show out of range by blinking "1000".15* 1 FTU = 1 NTUhours (the sample needs to be kept at room temperature prior to the analysis).•To obtain a representative sample, gently,but thoroughly, mix it before samples are taken. Do not shake (to prevent air bubbles)and do not let the sample settle.•It is recommended to calibrate the meter with the supplied HI 93703-10 @10 FTU* stan-dard at least once a month or more frequently for greater accuracy.•Before inserting vials into the instrument,wipe them with HI 93703-70 or a soft, lint-free tissue. Handle vials so that no finger-prints get on the areas where light passes (approx. the bottom 2 cm/1 inch).If you experience any problems in taking mea-surements, contact your dealer or the nearest Hanna Customer Service Center.SOURCES OF INTERFERENCE•Presence of floating debris and coarse sedi-ments which settle out rapidly will give false readings.•The infrared light source used for HI 93703-11 turbidity meter, complies with the ISO 7027 International Standard and can effec-tively minimize any errors due to colored dissolved substances. This effect, called "true color", is a common interference for most commercially available instruments operating in the range of visible light.•Air bubbles and the effect of vibrations that disturb the surface of the sample may give false results and should be avoided.•Dirty glassware could also affect readings along with scratched or dented vials.11LOG-ON-DEMAND:•right corner the reference number of the stored sample.NOTE: When the maximum number of samples has been reached (199), the LCD dis-play will show "FULL".This is a warning that you will be overwrit-ing the oldest sample recorded. To store the current sample, press the STO button again and this will overwrite the oldest sample in the memory. All samples are shifted (reference numbers reduced by one). Sample number one remains the oldest sample.CLEARING LOGGED DATA:•Press the ALT &CLR buttons to-gether. The display will show "CLR" for confirmation. Press ALT & CLR again to clear memory. To abort the operation,press any button.ALL SAMPLES PREVIOUSLY STORED WILL BE ERASED FROM MEMORY!14•Real Time Clockerror∗•EEPROM error ∗•Internal communica-tion error ∗•Internal Bus error ∗∗ Contact the HANNA office nearest to you.ENSURE ACCURATE MEASUREMENTS •Each time the cuvet is used, tighten the cap to the same degree.•Discard the sample soon after the reading is taken to avoid permanently clouding t he g lass.•All glassware used to contain the standards and the samples should be maintained clean,washed with the HI93703-50 cleaning solution and rinsed with HI 93703-0 or turbidity-free water.•Collect the samples in clean glass or plastic bottles, fit stoppers and perform the analysis quickly. If necessary, store the sample in a cool, dark place, for up to a maximum of 2412VIEWING LOGGED DATA:•played.•Press the right arrow to scroll between turbidity value, date and time of the sample.•Press the UP/DOWN arrows to view the samples and use the right arrow to scroll the date and time .•Press ALT & VIEW again to exit this mode.VIEWING AND SETTING DATE AND TIME:VIEWING:•between date and time.SETTING:•for 3-4 seconds.•and set the year.•13month and day, use UP/DOWN to set.•Press right arrow again to scroll to time, use UP/DOWN to set.•and time setup.Note: Press ALT & DATE to leave this mode without saving.ERROR CODES:Every time the meter is switched on, the Real Time Clock and EEPROM are tested, and if an error is found the corresponding error code will be displayed.The list of error codes is as follows:•NO cover error (check cuvet position)•Calibration error(check calibration standard value)。
DC-2010B智能型超声波测厚仪产品说明书
DC-2010B智能超声波测厚仪使 用 手 册北京市德光电子公司地址:北京市海淀区西北旺百旺茉莉园38号楼108邮编:100083电话:(010)51659992传真:(010)623140061目录一、概述 ---------------------------------------------------------- 1二、技术参数 ---------------------------------------------------------- 1三、测量原理 ---------------------------------------------------------- 1四、整机、部件及内容 ---------------------------------------------------------- 24.1 仪器整机 ----------------------------------------------------------- 24.2 显示部分 ----------------------------------------------------------- 24.3 键盘部分 ----------------------------------------------------------- 2五、测量前的准备 ------------------------------------------------------------ 25.1 仪器准备 ----------------------------------------------------------- 35.2 探头的选择 ----------------------------------------------------------- 35.3 被测体表面的处理技术 ---------------------------------------------------------- 3六、仪器的功能应用 ------------------------------------------------------------ 36.1 仪器开机 ----------------------------------------------------------- 36.2 测量 ----------------------------------------------------------- 36.3 仪器的校准 ---------------------------------------------------------- 36.4 仪器内置状态显示及操作 ------------------------------------------------------ 46.5 数据存储功能 ----------------------------------------------------------- 66.6 数据阅读功能 ----------------------------------------------------------- 66.7 背光功能 ---------------------------------------------------------- 6七、测量应用技术 ----------------------------------------------------------- 77.1 测量方法 ------------------------------------------------------------ 77.2 管壁测量法 ------------------------------------------------------------ 7八、维修及注意事项 ------------------------------------------------------------- 78.1 电源检查 ------------------------------------------------------------ 78.2 注意事项 ------------------------------------------------------------- 7九、仪器的标准配置 ------------------------------------------------------------- 7 附表 ------------------------------------------------------------- 82一、概述DC-2010B智能型超声波测厚仪,采用微处理器技术,利用超声波测量原理,可以测量金属及其他多种材料的厚度、声速进行测量。
2Bxxxx-xxx-3BD中文资料
2B SeriesSPECIFICATIONS STANDARD *SPECIAL ELECTRICALCenter Frequency (Fc)2000 to 9000 Mhz 1000 to 12000 MHz 3dB Relative Bandwidth (% of FC) 3 to 30 2 to 70Number of Sections Available 3 to 10 2 to 14Nominal Impedance 50 Ohms 50 to 300 Ohms Maximum Insertion Loss See Curve See Curve Maximum VSWR 1.5/1 1.3/1Attenuation in the StopbandSee GraphSee Graph Maximum Input Power (Average)(Watts to 10,000 ft.)300 x 3 db BW (MHz)(Loss Factor)(Fc MHz)See StandardMaximum Input Power (Peak)(Watts to 10,000 ft.)1500 x 3 dB BW (MHz)Fc (MHz)See StandardENVIRONMENTAL Shock 5 G's 15 G's Vibration2 G's15 G'sHumidity90% relative100% relative Altitude Unlimited UnlimitedTemperature Range (Operating)-25 to + 50 degreescelsius-54 to + 100 degreescelsiusTemperature Range (Non-Operating)-54 to + 70 degreescelsius-62 to +150 degreescelsiusMECHANICALApproximate Weight in oz.1.7 x L x W 1.0 x L x WMounting Provisions See below Consult FactoryINSERTION LOSS:The Maximum Insertion Loss atcenter frequency is equal to :LF x (N + 0.5) / % 3 dB BW + 0.1Where:LF= Loss Factor, N= Number ofSections% 3dB BW:3dB BW (MHz) x 100divided byCenter Frequency (MHz)Example:A 5 section 2B with a centerfrequencey of 5000 MHz and a 3dBBW of 500 MHz would have,.08 x 5.5 /10 = 4.4 /10 = 0.44 + 0.1= 0.5 dbMECHANICAL SPECIFICATIONSL Dimension = 1.5 inch = (0.5 x No. of Sections) Approx.W Dimension = 2950 / Fc (MHz) + 0.6 inch Approx.Connectors Available On 2B Series:Lark Code Type C DIM.Inches & MM Lark Code Type C DIM.Inches & MM A SMA JACK .375 & 9.5*G N JACK .736 & 18.7BSMA PLUG.507 & 12.9*HN PLUG.819 & 20.8Lark Engineering SD SERIES元器件交易网*C TNC JACK .750 & 19.1S SPECIAL*D TNC PLUG.844 & 21.4* Not recommended for use with this SeriesThe size shown is a standard used by Lark to facilitate a low cost, easily reproducible unit. Should you require another size, please submit all of your requirements-both electrical and mechanical. This will enable Lark Engineering to quote theoptimum design for your application.Lark Engineering SD SERIES元器件交易网STOPBAND SPECIFICATIONSThe graphs on the following pages define the normal specification limits on attenuation Lark bandpass filter series 2B, 3B, and 4B. The minimum level of attenuation in dB is shown as a "number of 3dB bandwidths from centerfrequency".Since the frequency characteristics vary for differing bandwidths, it is necessary to establish specifications for each bandwidth of filter. The different graphs represent various 3dB percentage bandwidths. Intermediate values should be interpolated. The 3dB percentage bandwidth is defined as follows:3dB Bandwidth (MHz) x 100divided byCenter Frequency (MHz)The exact relationship is as follows:1. 3dB Bandwidths From Center Frequency= Rejection Frequency (Mhz) -Center Frequency (Mhz) divided by 3dB Bandwidth (Mhz)Example:Given:2. Center Frequency = 5000 MHz Minimum 3dB Bandwidth = 500 MHzNumber of Sections = 5Find: Minimum attenuation levels at 4250 MHz and 5800 MHz.3dB BW's from Fc = 4250 - 5000 / 500 = - 1.5and 5800 - 5000 / 500 = + 1.6The answer can be read directly from the 10% graph. Using the 5 section curve at the point -1.5 (4250 MHz) we find the minimum level of attenuation is 40dB.At +1.6 (5800 MHz) the minimum level of attenuation is 50dB.For special requirements, please contact our Application EngineeringDepartment.STOPSP3.HTM元器件交易网STOPBAND SPECIFICATIONSSTOPBAND SPECIFICATIONSSTOPSP3.HTM元器件交易网STOPBAND SPECIFICATIONS。
HIF3HB-10DA-2.54DSA中文资料
Unit:mm Number of Contacts A B
30
39.1 35.56
34
44.18 40.64
40
51.8 48.26
50
64.5 60.96
60
77.2 73.66
64
82.28 78.74
Part Number HIF3H-6SA-2.54DSA HIF3H-10SA-2.54DSA HIF3H-12SA-2.54DSA HIF3H-14SA-2.54DSA HIF3H-20SA-2.54DSA HIF3H-25SA-2.54DSA
sProduct Specifications
Rating
Current rating: 2A
Operating Temperature Range: -30 to +85ç (Note 1) Storage Temperature Range: -10 to +60ç(Note 2)
Voltage rating: 300V AC Operating Humidity Range: 40 to 80%
e
P
: Pin header
r Contact material A: Phosphor bronze (DS: brass)
B: Brass
t Contact pitch : 2.54mm
y Contact type
DS : Right angle type
DSA : Straight type
W : Wrapping type
Note 1: Includes temperature rise caused by current flow. Note 2: The term "storage" refers to products stored for long period of time prior to mounting and use. Operating Temperature Range and
海康威视DS-3S系列HD-SDI光端机用户手册说明书
DS-3S系列综合平台HD-SDI光端机用户手册杭州海康威视数字技术股份有限公司技术热线:400-700-5998UD.6L0103D0063A01非常感谢您购买我司产品,如您有任何疑问或需求请随时联系我们。
本手册适用于以下产品:本手册可能包含技术上不准确的地方、或与产品功能及操作不相符的地方、或印刷错误。
我司将根据产品功能的增强或变化而更新本手册的内容,并将定期改进及更新本手册中描述的软硬件产品。
更新的内容将会在本手册的新版本中加入,恕不另行通知。
本手册中内容仅为用户提供参考指导作用,不保证与实物完全一致,请以实物为准。
本手册中提到的部件、组件和附件仅作说明之用,不代表购买机型的配置,详细配置请以装箱单为准。
0100001021128安全使用注意事项此内容的目的是确保用户正确使用本产品,以避免危险或财产损失。
在使用此产品之前,请认真阅读此说明手册并妥善保存以备日后参考。
如下所示,预防措施分为“警告”和“注意”两部分:警告:无视警告事项,可能会导致死亡或严重伤害。
注意:无视注意事项,可能会导致伤害或财产损失。
事项提醒用户防范潜在的死亡或严重伤害危险。
事项提醒用户防范潜在的伤害或财产损失危险。
警告在本产品安装使用中,必须严格遵守国家和使用地区的各项电气安全规程。
请使用正规厂家提供的电源适配器,供电电源要求为DC12V/1A。
在接线、拆装等操作时请一定要将电源断开,切勿带电操作。
如果设备工作不正常,请联系购买设备的商店或最近的服务中心,不要以任何方式拆卸或修改设备。
(对未经认可的修改或维修所导致的问题,本公司不承担责任)。
光端机的光器件所产生的光源能对人的眼睛产生永久性伤害,切勿用眼睛直视光端机的光器件和通电状态下光端机的光纤接口。
在光端机上插拔光纤时,切断电源。
注意请不要使物体摔落到设备上或大力震动设备,并使设备远离存在磁场干扰的地点。
避免将设备安装到表面震动或容易受到冲击的地方。
(忽视此项可能会损坏设备)请不要在高温(超过75℃)或低温(低于-40℃)或高湿度地点安装设备。
超声波测厚仪中文版说明书资料
第二步:通过 (增减数值)和 (移动光标)输入试块厚度,按 进入下一步
第三步:通过耦合剂将探头耦合到与输入试块厚度相应的试块上,4秒钟后,校准完成,仪器自动返回待测界面
注:校准后的材料声速会显示在厚度测量界面的顶部。
两点校准需要与被测物体材料相同的薄、厚两块试块并且待测物体厚度在两试块厚度范围内。此校准方式可减少非线性的测量误差,得到高精度的测厚结果。具体步骤如下:
高精度型
7.5M,Ф10
0.65~250mm
10mm
7.5MHz
-10~+50℃
高温型
ZW5P
4.0~80mm
12mm
5MHz
-10~-300℃
铸铁专用型
2M,Ф22
3~50mm(铸铁)
22mm
2MHz
-10~+50℃
选配2
序号
名称
数量
备注
1
USB数据线
1
带USB口测厚仪
2
上位机软件
1
带USB口测厚仪
备注:测量范围取决于不同厂家生产的不同批次的探头的性能、材料的组织情况和材料的表面状况等,耐高温温度高低取决于探头、耦合剂等。由于我公司生产的该型号系列超声波测厚仪能够自适应探头的性能参数,故匹配合适的探头能够满足用户的要求。
测厚仪主机如下图所示。
图2-1 主机
测厚仪键盘如图2-2所示。
图2-2 键盘
型号参数sw312测量范围标准模式200mm钢探头分段适用测量范围穿透涂层模式测量下限曲面模式显示精度材料声速测量精度接收带宽测量频率01mm001inch065500mm钢探头分段适065500mm钢探头分段适25mm钢探头分段适15mm10mm75mhz6mm探头10mm12mm75mhz6mm探头01mm001inch50918699ms05h005mm钢材料不同精度也不同1mhz10mhz3db220秒可设置3vdc两节aa碱性电池280小时背光自动100小时背光打开12864点阵lcd136l20hmm001mm0001inch01mm001inchsw6sw6usw7sw7u065500mm钢探头分段适用测量范围065mm500mm显示精度001mm测量范围065mm500mm25mm穿透涂层显示精度001mm数据存储sw7usw7a350mm钢探头分段适用工作时长显示屏外形尺寸176g含电池1050使用高温探头工作温度
b-hyve 3 in 1水质测试仪-使用手册说明书
Measurement:4. When the Conductivity reading stabilized, the will appear on display & user can take the measurement.5. To select to TDS Mode, press button to enter the Setup Menu and ‘PArA’ will appear.14. To take TDS measurement, rinse sensor before dipping to test solution & repeat steps 2-4.15. To select to Salinity Mode now, press button to enter the Setup Menu and ‘PArA’ will appear.Note: Tester automatically shuts off after 8.5 minutes of nonuse to conserve batteries.Calibration:1. This tester allows only 1 Point Calibration.2. For Conductivity Mode, 1 Point Auto or Manual calibration can be done while for TDS & Salinity Mode, only 1 Point Manual TDS & Salinity Calibration can be done.4. Dip sensor in at least 30 mm of Conductivity Standard (recommended 1410 µS/cm solution).5. Stir gently and press button to start Conductivity calibration.6. It will show ‘CAL’ follow by the default Cond. value & will appear on display during calibration.8. After the will appear on display, wait for Auto scanning to lock.9. When the reading is within the calibration window of Auto Conductivity Standards it will Auto11. Upon exit to Conductivity Mode, it will show the Auto calibrated value (80 or 1410 or 12.90).12. When the Conductivity reading is out of the calibration window of Auto Conductivity Standards,it will enter into Conductivity Manual Calibration Mode.13. Press button to decrease value to the set Conductivity reading (±40% of default reading).Operating InstructionsOakton ® EcoTestr CTS Waterproof Pocket Tester15. Upon exit to Conductivity Mode, it will show the Manual calibrated value.16. To calibrate a new Conductivity Point, rinse sensor before dipping into test solution & then repeat steps 2-15.17. To calibrate TDS Mode, first select to ‘PArA tdS’ & set ‘tdS.F , correctly (refer to steps in Setup Menu).18. To start TDS Manual Calibration, dipped sensor at least 30 mm into the TDS Calibration Standard & repeat steps 2-15.19. To calibrate Salinity Mode, first select to ‘PArA SALt’ (refer to steps in Setup Menu).20. To start Salinity Manual Calibration, dipped sensor at least 30 mm into the Salinity Calibration Standard & repeat steps 2-15.21. To abort Conductivity/TDS/Salinity calibration, press button to escape.Note: The Auto Conductivity Standards are 84 µS/cm, 1413 µS/cm & 12.88 mS/cm.‘r.SEt’.‘dEg’.ºC’ ºC/9.0ºF of default ATC).22. Press button to toggle from ‘t.CAL ’ back to ‘PArA’ again. The Setup Menu cycle will repeat.23. To exit from Setup Menu back to Measurement Mode, press button to escape. Error Messages:1. ‘ ’ – Weak batteries & need replacement soon.2. ‘bAt Lo’ (Low Battery supply) – Tester automatically shut offs without going to Measurement Mode & batteries need immediate replacement.3. ‘StBL Err’ ( Stabilizing Error) – Manual Decrease/Confirm of calibration when reading still stabilizing.4. ‘Or’ (Over Range) – The Conductivity, TDS, Salinity & ATC Temperature reading is above the measuring range of tester.5. ‘Ur’ (Under Range) – The ATC Temperature reading is below the measuring range of tester.menumenumenumenucalesccal esc calescCAL。
DBB-III变压器变比组别测试仪概要
DBB-III变压器变比测试仪DBB-III Transformer Turn Ratio Tester使用手册User's Manual 湖北电保姆电力自动化有限公司H ubei E-Nanny Electric Power Automation Co.,LTD尊敬的用户:感谢您选用我公司生产的DBB-III变压器变比组别测试仪。
希望本手册对您使用该产品提供尽可能详细的技术资料及帮助信息。
在正式使用该仪器之前,请仔细阅读本说明书,以确保您对本产品的安全正确使用。
如果您对说明书中所述内容有任何疑问,或者需要业务咨询或技术支持,欢迎您与我公司销售部或技术部取得联系,我们将竭诚为您服务。
阅读完本说明书后,请妥善保管,以备后用。
重要提示:1仪器在不使用的情况下,请及时关闭电源!2充电电池属于消耗部件,应注意维护,在使用时充电电池有效容量会随时间逐渐降低,从而使有效使用时间缩短,为了尽量提高电池寿命,请注意以下维护措施:2.1如果长期不使用仪器,请定期进行充、放电,电池应至少每月充、放电一次。
2.2严禁亏电使用,亏电将严重缩短电池寿命,甚至使电池报废,当仪器欠电时,应马上关闭电源,进行充电。
避免因电池放电时间过长而导致电池失效。
2.3充电灯:充电过程中亮红色;充电完成后亮绿色。
目录1概述 (12性能特点 (13技术指标 (24面板及接线端子介绍 (25操作使用说明 (35.1测试接线 (35.1.1单相变压器或单相PT测试接线 (35.1.2三相变压器测试接线 (35.2智能电量管理 (35.3打印机使用说明 (45.4使用操作 (45.4.1变比测试 (45.4.2存储查询 (75.4.3时钟设置 (85.4.4厂家设置 (86注意事项 (97售后服务 (9一、概述在电力变压器的半成品、成品生产过程中,新安装的变压器投入运行之前以及根据国网的预防性试验规程,要求对运行的变压器定期进行匝数比或电压比测试。
HB5024
Preliminary HB5024高精度16位LED恒流驱动器HB5024是一款用于大屏幕LED的低压差、高精度16位恒流驱动芯片。
它是内建的16位移位寄存器与栓锁功能,可以将串行的输入数据转换成并行输出数据格式。
HB5024的输入电压范围值为3.3V至5V,提供16个电流源,可以在每个输出级提供3mA - 45 mA恒定电流以驱动LED。
并且单颗IC内输出通道的电流差异小于±2%;多颗IC间的输出电流差异小于±3%;恒定输出电流随着输出端耐受电压(V DS)变化,被控制在每伏特0.1%;且电流受供给电压(V DD)、环境温度的变化也被控制在1%。
HB5024可以选用不同阻值的外接电阻来调整其输出级的电流大小,藉此机制,使用者可精确地控制LED的发光亮度。
HB5024的设计保证其输出级可耐压17V,因此可以在每个输出端串接多个LED。
此外,HB5024亦提供30MHz的高时钟频率以满足系统对大量数据传输上的需求。
z16个恒定电流输出通道z恒定电流输出值不受输出端负载电压影响z恒定电流范围值:3mA – 45mA@ V DD= 5V3mA – 30mA@ V DD= 3.3Vz极为精确的电流输出值:通道间最大差异值:<±2%芯片间最大差异值:<±3%z利用一个外接电阻,可设定电流输出值z快速的输出电流响应,OE(最小值):100ns @ V DD= 3.3Vz高达30MHz时钟频率z具Schmitt trigger输入装置z操作电压:3.3V/5Vz封装形式:SSOP24L-1.0-D1.50SSOP24L-0.635-D1.40z抗静电损坏能力:≥4000VHB5024典型应用图引脚描述引脚图功能示意图SDO输入及输出等效电路IN OE输入端INLE 输入端INCLK ,SDI 输入端SDO 输出端时序图真值表CLK LE SDIDH LX L最大限定范围特性代表符号最大工作范围 单位电源电压 V DD 0~7.0 V 输入端电压 V IN -0.4~V DD +0.4 V输出端电流 I OUT+90 mA输出点耐受电压 V DS -0.5~+17.0 V 时钟频率 F CLK 25 MHz 接地端电流I GND +1000 mAGF 包装 1.9 GP 包装 1.4 消耗功率(在四层印刷电路板上,25°C 时)GTS 包装P D 1.4W GF 包装 66.66GP 包装 88.39 热阻值(在四层印刷电路板上,25°C 时)GTS 包装 R th(j-a) 88.39°C/W 静电测试人体静电模式(MIL-STD-883G Method 3015.7)HBM≥4000 VIC 工作时的环境温度 T opr -40~+85 °C IC 存储时的环境温度 T stg -55~+150°CHB5024 Preliminary高精度16位LED恒流驱动器=3.3V)动态特性(V直流特性测试电路动态特性的测试电路GNDVDDOE CLK LE SDIR-EXTOUT15OUT0OUTI DDV 函数产逻辑输入波形时序的波形图应用信息恒定电流输出当客户将HB5024应用于LED面板设计上时,通道间与通道间,甚至芯片与芯片间的电流,差异极小。
中文说明书--Hydrolab DS5X,DS5和MS5水质多功能探头
6.8.1标准参比电极………………………………………………………………………….......………………………………….…45
6.8.2 pH全能传感器………………………………………………………………………….......………………………..………..…46
5.2.4最低流量要求…………………………………………………………………….......………………….………………………35
5.2.5不能潜水时的配置……………………………………………………………….......………………....………………………35
第6章维护………………………………………………………………………….......…………………………...........………………37
4.1.6其他参数设置……………………………………………………………………………………………………………………22
4.2校正….………………..……………………………………………………........………………………………………………………22
4.2.1使用测量器校正传感器…………………………………………………...............……………………………………………22
4.3.1使用测量器收集数据…………………………………………………………………………………………..................……27
4.3.2使用PC和Hydras 3 LT收集数据………………………………………………………………………………………………27
4.3.3使用DS5/DS5X/MS5进行无人监测……………………………………………………………………………………..……27
DB3B中文资料
Value
Unit
-40 to + 110 °C
-40 to + 125
Conditions
*Electrical characteristic applicable in forward and reverse directions. **Connected in parallel with the devices.
Tel: +55-11-5574-7949 Fax: +55-11-5572-0052
TAITRON COMPONETS INCORPORATED, SHANGHAI REPRESENTATIVE OFFICE CROSS REGION PLAZA, 899 LINGLING ROAD, SUITE 18C, SHANGHAI, 200030, CHINA Tel: +86-21-5424-9942 Fax: +86-21-5424-9931
Rev. A/DX 2007-06-04 Page 4 of 4
Rev. A/DX 2007-06-04 Page 1 of 4
元器件交易网
Bidirectional DIAC Trigger Diode DB3B
Symbol
TJ TSTG
Description
Operating Temperature range Storage Temperature Range
Circuit Repetitive Peak on-state Current
Typical Thermal Resistance
Value Unit
Min. Typ. Max.
30 32 34
V
HIF3BA系列连接器商品说明书
HIF3BA-GPIN HIF3BA-40D-2.54C HIF3BA-10D-2.54CHIF3BA-14D-2.54CHIF3BA-20D-2.54CB15Ribbon Cable connector Compliant with MIL StandardHIF3B Seriess Features1. Product Compliant with MIL StandardHIF3B series has been developed as a product compliant with MIL standard, and used for wide applications.2. UL Approval ProductHIF3B series connectors are UL approved.3. Mechanism to Prevent Mis-insertionThis connector is equipped with the mechanism to prevent Mis-insertion as follows.1The system provides the convex area to insert the guide-key on the pin header side, and to guide it in combination with the socket convex area (MIL standard).2The system embeds and guides the polarizing key in the socket holes.4. Applicable Cable AWG#28The applicable cable is UL2651 AWG#28 flat cable (7 cores./0.127mm, jacket dia. 0.9±0.1mm).s Product SpecificationsJ a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .B16HIF3B Series q Ribbon Cable connector Compliant with MIL Standards Ordering InformationHIF 3B - * D - 2.54 Rqwre tyq Series Name: HIFw Series No.: 3B, 3BA, 3BB (50, 60, 64 contacts only )e Number of contacts : 6,10,14,16, 20, 26, 30, 34, 40, 50, 60, 64 r Contact alignment : D : Double t Contact pitch : 2.54mmy Connection typeR : ID type q SocketHIF 3B - *P A - 2.54 DSqwretyuq Series Name : HIF w Series No.:3B: (14 contacts not included)3BC: (10 contacts only) 3BA, 3BB: (50, 60, 64 contacts only)3BD: (10 contacts only)e Number of contacts : 6,10,14,16, 20, 26, 30, 34, 40, 50, 60, 64r P : Pin headertA: Selective gold plated y Contact pitch : 2.54mm u Contact styleDS : Right angle type DSA: Straight typeq Pin HeaderJ a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .B17HIF3B Series q Ribbon Cable connector Compliant with MIL Standards Socket (With guide to prevent mis-insertion)Unit:mmNote1, Note2: The number of polarizing keys and polarizing keyways changes according to products. Refer to the list as shown below.Note3: The 50, 60 and 64 contact connector contain two types of polarizing guides. Use the products, referring to Notes 1 and 2.Note4: The 6 contact has no polarizing mark.Body Protector ClampJ a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .B18HIF3B Series q Ribbon Cable connector Compliant with MIL StandardsSocketNote1: The number of polarizing keys and polarizing keyways changes according to products. For details, refer to the list as shown below.Note2: The 6 contact has no polarizing mark.Body Protector ClampUnit:mmThe products marked with 5comply with MIL standard.J a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .B19HIF3B Series q Ribbon Cable connector Compliant with MIL Standards Four Wall Angle Through holeBPCB mounting patternNote 1, Note 2: The number of polarizing slot and key installed positionschanges according to products. Refer to the list as shown below.Note 3: The spacer moves to the right according to the number ofcontacts.Note 4: The 10, 50, 60 and 64 contact connectors contain two types ofpolarizing slots.Use products, referring to (Note 1) (Note 2).s n=number of contactsUnit:mmThe products marked with 5comply with MIL standard.J a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .B20HIF3B Series q Ribbon Cable connector Compliant with MIL Standards Four-Wall Straight Through holeBPCB mounting patternNote 1, Note 2: The number of polarizing slot and key installed positionschanges according to products. Refer to the list as shown below.Note 3: The spacer moves to the right according to the number ofcontacts.Note 4: The 10, 50, 60 and 64 contact connectors contain two types ofpolarizing slots.Use products, confirming (Note 1) (Note 2).Note 5: The 6 contact has no polarity mark.s n=number of contactsUnit:mmJ a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .B21HIF3B Series q Ribbon Cable connector Compliant with MIL Standards Three Wall Angle TypeBPCB mounting patternNote 1, Note 2: The number of polarizing slot and key installed positionschanges according to products. Refer to the list as shown below.Note 3: The spacer moves according to the number of contacts.Note 4: The 10 contact connector consists of two types.Use products, confirming (Note 1) (Note 2).s n=number of contactsUnit:mmThe products marked with 5comply with MIL standard.J a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .B22HIF3B Series q Ribbon Cable connector Compliant with MIL Standards Three Wall Straight Through holeBPCB mounting patternNote1,Note2: The number of polarizing slot and key installed positionschanges according to products. Refer to the list as shown below.Note3: The spacer moves to the right according to the number ofcontacts.Note4: The 10 contact connector consists of two types.Use products, referring to (Note 1) and (Note 2).s n=number of contactsUnit:mmThe products marked with 5comply with MIL standard.J a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .B23HIF3B Series q Ribbon Cable connector Compliant with MIL Standards Four Wall Wrapping TypeBPCB mounting patternNote 1, Note 2. The number of polarizing slot and key installed positionschanges according to products. Refer to the list as shown below.Note 3. The spacer moves to the right according to the number ofcontacts.Note 4. The 10, 50, 60 and 64 contact connectors consists of two types.Use products, confirming (Note 1) (Note 2).Note 5. The mark *indicates the number of contacts.Note 6. The nut built-in specification product is also provided.The product can be fixed by M2 screws from the rear e the screw of (board thickness) +4 mm under the neck.s n=number of contactsUnit:mmThe products marked with 5comply with MIL standard.J a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .s Four Wall Straight Through hole [Flux Blister Prevention Type ]BPCB mounting patternNote1: The number of polarizing slot and key installed positions changesaccording to products. Refer to the list as shown below.s n=number of contactsUnit:mmJ a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .sTwo Stage Staking Right Angle Through holeNote 1, Note 2: The number of polarizing slot and key installed positions changes according to products. Referto the list as shown below.Note 3: The spacer moves to the right according to the number of contacts.Note 4: The 10, 50, 60 and 64 contact connectors consists of two types.Use products, confirming (Note 1) (Note 2).Note 5: The mark *ndicates the number of contacts.Note 6: The locator is located optionally.Unit:mmThe products marked with 5comply with MIL standard.J a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .BCombination PatternBPCB mounting patternsMounting Hole SpacerNote : Fix the HIF3-mounting hole spacer by screws between upper stage and lower stage connectors.Note : 2 pieces are contained in a bag.J a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .BPolarizing KeyNote1: One unit of thisproduct is a set of five pieces in conjunction with a runner. The unit for sale is defined one pack containing 20pieces.Note2: This product isapplicable to the HIF3BA-*D2.54R product.HIF3-GPIN(A)HIF3BA-GPINNote1: One unit of thisproduct is a set of five pieces in conjunction with a runner. The unit for sale is defined one pack containing 20pieces.Note2: This product isapplicable to HIF3A-*D2.54R, HIF3C-*D2.54C and HIF3BA-*D2.54C products.HIF3B-GK CL562-0601-8J a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .B HIF3-Multi Clamp B HIF3-*CL Pull Tabq Low Profile Lock Pin HeaderB Lockq F Type Lock Pin HeaderLocking range more reduced than conventional lock type.This clamp is used for intermediate connection in the bus-line system, etc. Remove compulsory force from the insulation displacement area of the connector in intermediate connection.Note: The pin header corresponds to the HIF3BAEseries (lock E).This pull tab is used for the HIF3 series equipped with cable clamp function. Remove all compulsory force, which is loaded on the insulation displacement area of the connector for extraction.Note: This HIF3-* Pull Tab can not be used for HIF3BA-*PD.Note: The pin header corresponds to the HIF3BAE series (lock E).27.321.5J a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .s Socket for CrimpingJ a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .sCover Case for Crimping socketNote 2: Note that the product cannot be used with AWG #20.Applicable jacket diameters are as described below.20 contacts: 1.7 mm diameter MAX26 to 40 contacts: 1.6 mm diameter MAX 50 to 60 contacts: 1.4 mm diameter MAXJ a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .RoHSs Contact for Crimping SocketRoHSRoHSRoHS RoHSRoHSJ a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .B Toolsq Crimping ToolManual Crimping Tool HIF3-T2226HCq Automatic Crimping Tool (Type: CM-105)q Contact Extraction Tools How to use the extraction tool(1) How to extract contactsAs shown in Figure 1, where the extraction tool is inserted in the lance fixed slot on the insulated case, slightly pull the cable, and the contact can be removed.(2) How to adjust the lance (raise)In order to re-insert the contact removed from the insulated case,raise the contact lance area using the tool A, and re-insert the contact, asshown in Figure 2.Figure 1Part Number HIF1-POCL No.550-0049-7J a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .Note1: AP106-HIF3-22-28SCF and AP105-HIF3-22-28CFA can be modified by changing a few parts.J a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .HIF3B Series q Ribbon Cable connector Compliant with MIL StandardB Socket Side (Crimping) Assembling Procedures(1) As shown in Figure 1, peel the applicable cable (AWG#20 to #26) jacket, and connect it using crimping jig HIF3-TA2022HC,HIF3-TA2226HC, or HIF3-TA2426HC. In this case, insert the cable so as to hit the contact cable stripper position as shown Figure 2.(2) After connection as shown Figure 2, check the contact direction, and insert the contact as shown Figures 3 and 4. Slightly pull the cable, and check whether the contact lance position is firmly fixed to the insulation case, as shown in the area (A).Note1 : For handling procedures for special crimping tools, refer to the "Handling Instruction Manual".Note2 : Wire strip length: Refer to crimp condition sheet.Figure 1Figure 2Figure 3Figure 4Wire strip lengthJ a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .HIF3B Series q Ribbon Cable connector Compliant with MIL StandardHIF3B Connection Circuit DiagramType ABType ADType CDT y p e A BT y p e A D T y p e C D J a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .HIF3B Series q Ribbon Cable connector Compliant with MIL StandardType ACType CCType AA T y p e A CT y p e C CT y p e A AJ a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .HIF3B Series q Ribbon Cable connector Compliant with MIL StandardHIF2E R(S) A to HIF3B Connection Circuit DiagramType AAType ACJ a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .HIF3B Series q Ribbon Cable connector Compliant with MIL StandardType BAType BCJ a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .HIF3B Series q Ribbon Cable connector Compliant with MIL StandardHIF2E R(S)B to HIF3 Connection Circuit DiagramType AAType ACJ a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .HIF3B Series q Ribbon Cable connector Compliant with MIL StandardType BAType BCJ a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .HIF3B Series q Ribbon Cable connector Compliant with MIL Standards Features1. In-line TypeThis connector can be used for internal wiring cable to cable within equipment.2. CompatibilityThis connector is compatible with HIF3A series as well as HIF3B series socket.3. Applicable CableThe applicable cable is UL2651 AWG#28 flat cable (7 pcs./6.127mm, jacket diameter: 0.8to 1.0mm).s Product SpecificationsNote 1: Includes temperature rise caused by current flow.Note 2: The term "storage" refers to products stored for long period of time prior to mounting and use. Operating Temperature Range andHumidity range covers non conducting condition of installed connectors in storage, shipment or during transportation.Note 3: Information contained in this catalog represents general requirements for this Series. Contact us for the drawings and specifications for aspecific part number shown.s Ordering InformationHIF3BA - *P D - 2.54 R - MCqerwutys Materialq Series Name: HIF3BB (50, 60, 64 contacts only)HIF3BD (10 contacts only)HIF3BAE (60 contacts only)w Number of Contacts : 10, 16, 20, 26, 30, 34, 40, 50, 60and 64e P : Plug r D : contact alignment : D : Double t Contact Pitch : 2.54mm y Connection type : Ribbon cable u MC: Mold clampJ a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .HIF3B Series q Ribbon Cable connector Compliant with MIL Standards PlugNote 1, Note 2: The number of polarizing slot and key installed positions changes according to products.The 10 contact connector only has no position for polarizing key insulation.Note 3: The number indicated in parentheses are sizes for 60 and 64 contact connectors.Note 4: The HIF3BAE-60PD-2.54R-MC product partially differs in a locking form, and the mating member isapplicable for HIF3A only.Unit:mm*D sizeunlocking sizeJ a n .1.2017 C o p y r i g h t 2017 H I R O S E E L E C T R I C C O ., L T D . A l l R i g h t s R e s e r v e d .HIF3B Series q Ribbon Cable connector Compliant with MIL Standard BConnection ProceduresType AOType BOType COType DONote1: Cable length tolerance Less than 500 (mm)More than 500 (mm)Note2: When a cable such as a twist cableor a slit (like a roller screen) cable isused, the cable pitch will changeaccording to cable manufacturers.If connection failure has occurred,please contact Hirose sales.+10+3Jan.1.217Copyright217HIROSEELECTRICCO.,LTD.AllRightsReserved.HIF3BA-20PD-2.54 R-MC HIF3BA-30D-2.54CHIF3BA-34D-2.54CHIF3BA-34P-2.54WHIF3BD-10PD-2.54R-MCHIF3BA-14P-2.54 W HIF3BA-34PD-2.54R-MCHIF3BA-40PD-2.54R-MCHIF3BD-10P-2.54WHIF3BA-GPIN HIF3BA-40D-2.54C HIF3BA-10D-2.54CHIF3BA-14D-2.54CHIF3BA-20D-2.54C。
海尔 HBWS-S25 专业杀菌盐中央软水机 使用说明书
产品说明书HB Soft Series软水机HB SOFT 10海尔牌HBWS-S10型软水机海尔牌HBWS-S15型软水机海尔牌HBWS-S25型软水机HB SOFT 15HB SOFT 25目 录总则请仔细阅读本用户手册,并在使用设备前熟悉设备的操作方法。
本用户手册包含产品型号如下:-HBWS-S10-HBWS-S15-HBWS-S25请在安装和使用前阅读本手册,严格要求步骤安装。
请妥善保管此说明书,以为您更好地使用软水机提供指导。
请遵循当地关于安全措施及环境保护的规定使用产品。
注意:请在规定时间内对产品进行维护及保养。
安全指示危险:有触电危险,须由专业人士操作警告:勿使用强酸或强碱清洁。
注意:须由专业人士操作。
注意:设备工作时不要随意移除相关盖板。
备注:如需要请使用防护衣服。
备注:附加信息。
适用范围HB SOFT系列软水机设计应用于家用软化或部分软化水质,不适用于除此以外的应用范围。
产品说明HB SOFT 系列软水机包括:标准配置:1.多路阀及电子控制器2.混合阀3.软化罐体及离子交换树脂4.软水出口5.硬水出口6.排污口7.防溢管连接8.电源连接9.用户使用手册10.软管夹接口11.2米排污管12.翻盖13.AQUATEST 硬度测试14.储盐槽15.盐箱16.包装材料(见第8页)17.技术参数及产品型号(见第8页)附加配置:18.单向阀: ” (DN: 20/20)34810131811121121415456723显示与控制元件标准出厂设置初次设置注意初次设置所需时间: 再生时间:不同型号内部设置有所不同 (数分钟)可设置任意时间进水硬度/容量:300 ppm, 10升型号供水量为1566升设置当前时间:接通电源后听到阀门转动声,设备进入工作模式, 可能需要等待几分钟. 按下SET/RETURN键开始设置,小时位开始闪烁,用UP/DOWN进行调整后再按SET/RETURN键,分钟位开始闪烁,再用UP/DOWN键进行调整。
TTH HBBSS-33000000DDBB 数显直读布氏硬度计使用说明书
THBS-3000DB数显直读布氏硬度计使用说明书北京时代光南检测技术有限公司服务电话:************目录一简介 (1)二主要技术参数 (1)1试验原理 (1)2技术参数 (2)三测试标尺(压头和力值)的选择 (2)1标尺选择 (2)2.布氏硬度试验标尺、压头、试验力的对应关系(表2) (3)3选择方法 (3)4示值允许误差及示值重复性(表3) (3)四仪器的安装和调试 (4)1. 硬度计的工作条件 (4)2. 硬度计的拆箱 (4)3 硬度计安装 (5)4 操作面板功能介绍 (6)5 试样要求 (8)6 硬度计的使用 (8)五硬度计的保养及注意事项 (11)六 RS232超级终端设置: (12)七附件 (15)一简介数显布氏硬度计是光机电一体化的高新技术产品,该硬度计造型新颖,具有良好的可靠性,可操作性和直观性,是采用精密机械技术和光电技术的新型布氏测试仪器。
该机采用计算机软件编程,光电传感等技术。
通过按键输入,选择测试方法与硬度相互对照、储存等,在LCD大屏幕显示屏上能显示试验方法、试验力,测量压痕长度、硬度值、试验力保持时间、试验力与硬度测量范围、测量次数,并能键入年、月、日期,试验结果和数据处理等,通过打印机输出,RS-232接口与计算机连网。
布氏硬度试验主要用于铸铁、钢材、有色金属及软合金等材料的硬度测定,此外还可以用于硬质的塑料、电木等某些非金属材料硬度的测定。
适用于工厂、车间、试验室、大专院校和科研机构。
二主要技术参数1试验原理布氏硬度试验是用一定直径的钢球(D),以规定试验力(F)压入被测试物体的表面(图1),经规定的保持试验力时间后,卸除试验力,用测微目镜测量试件表面的压痕直径(d),计算压痕的球形表面积所承受的平均压力(N/mm2),即布氏硬度值。
图(1)2技术参数试验力级数: 62.5kgf (612.5N) 500kgf(4900N)100kgf(980N) 750kgf(7350N)125kgf(1225N) 1000kgf(9800N)187.5kgf(1837.5N) 1500kgf(14700N)250kgf(2450N) 3000kgf(29400N)硬度测试范围:(8~650)HBW测微目镜放大倍率: 20倍测微目镜最小分度值: 0.625um试样最大高度: 185mm压头中心至机体最大距离: 135mm电源电压: AC 220V额定功率: 60W外形尺寸: (786×565×245)mm重量: 130kg三测试标尺(压头和力值)的选择1标尺选择为了确保布氏硬度测试的正确,标尺选择时应按表1和表2选择。
HBB3G说明书
HB-B3G使用说明一.接线说明1:信号端说明CP/CW,运行指令脉冲输入端子,信号性质脉冲边沿有效UD/CCW,运行方向输入端子,信号性质高低电平有效COM, 信号公共端信号性质为正电源(注:内部已接1K电阻,只要保证内部光耦工作在15~20mA,过大会损坏光耦,过小会造成驱动器工作时丢步。
)WF, 细分控制信号输入端,(注:第二步距角时能)信号性质高低电平有效Pd.使能控制信号,信号性质高低电平有效AL, 报警输出端,输出电路为单个P181的三四端2:强电端接线说明A: 步进电机插头1#线,B: 步进电机插头3#线,C: 步进电机插头5#线,AC220: 接市电220~V,(注:若电机的运行方向与控制信号相反,可交换A.B.C.三端子中的任意两个,其中一个保持不动.)二.主菜单说明Ed ——驱动器内部参数调整主菜单。
dP ——驱动器状态参数查询主菜单。
EP ——驱动器参数管理主菜单ERRCD ——驱动器报警状态主菜单.三.子菜单说明1:Ed.子菜单说明00:使能控制位——0:使能位有效,1:无使能控制,2:使能位有效,且首脉冲忽略01:指令脉冲方式位——0:CP+UD, 1:CW+CCW,2:正交脉冲方式02:第一步距角设置——范围250~6400,单位为脉冲个数/转(注:需为50的整数倍数值)03:第二步距角设置——范围3600H~8CA0H(注:需为第一步距角的整数倍数值为16进制)04:相电流设定——范围128~232(注:该数为16进制数以下该形式的数偕同),为128时,相电流约4A,为160时,相电流约10A.05:过电压值设定——范围350~550,为400时.06:过热温度设定——范围600~780,600对应60℃,07:调制频率设置,保留原始设置不调。
改1280增加力气!2010.8.18.08:最小脉宽设置,保留原始设置不调。
09:采样频率转换,参数范围200~780,保留原始设置不调。
stm32f103中文资料
DST系列B型示波器说明书(Ver0.9)
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
HIF3HA-10DA-2.54DSA 618-0121-2
10
13.7 10.16 HIF3HA-34DA-2.54DSA
HIF3HA-10DA-2.54DSC 618-0191-8
HIF3HA-34DA-2.54DSA
HIF3HA-12DA-2.54DSA 618-0102-8
12
16.24 12.7 HIF3HA-40DA-2.54DSA
3. Contact Resistance 15m ohms max.
4. Vibration
No electrical discontinuity of 1µs or more
5. Humidity (Steady state) Insulation resistance: 10M ohms min.
CL No. 562-0713-1 562-0719-8 562-0723-5 562-0655-7 562-0704-0 562-0705-3
Unit:mm Number of Contacts A B
6
16.24 12.7
10
26.4 22.86
12
31.48 27.94
14
36.56 33.02
CL No. 618-0165-8 618-0143-5 618-0216-7 618-0144-8 618-0145-0 618-0146-3 618-0147-6 618-0148-9 618-0149-1
CL No. 618-0150-0 618-0153-9 618-0141-0 618-0152-6 618-0154-1 618-0142-2 618-0161-7
Number of Contacts A B
4
6.0 2.54
8
11.16 7.62
10
13.7 10.16
12
16.24 12.70
14
18.78 15.24
16
21.32 17.78
Part Number HIF3H-18DB-2.54DS HIF3H-20DB-2.54DS HIF3H-24DB-2.54DS HIF3H-26DB-2.54DS HIF3H-30DB-2.54DS HIF3H-34DB-2.54DS HIF3H-40DB-2.54DS HIF3H-50DB-2.54DS HIF3H-60DB-2.54DS
Note 1: Includes temperature rise caused by current flow. Note 2: The term "storage" refers to products stored for long period of time prior to mounting and use. Operating Temperature Range and
7. Durability (Mating/un-mating) Contact resistance: 15 m ohms max.
500 cycles
8. Resistance to Soldering heat No deformation of components affecting performance. Flow: 260ç for 10 seconds Manual soldering: 300ç for 3 seconds
HIF3HA-16DA-2.54DSA 618-0103-0
HIF3HA-40DA-2.54DSA
HIF3HA-16DA-2.54DSA 618-0123-8
16
21.32 17.78 HIF3HA-50DA-2.54DSA
HIF3HA-16DA-2.54DSC 618-0192-0
HIF3HA-50DA-2.54DSA
Operating Humidity Range: 40 to 70% (Note 2)
Item
Specification
1. Insulation Resistance 1000M ohms
2. Withstanding Voltage No flashover or insulation breakdown.
HIF3H A - * D A - 2.54 DSA
q
w
e rt
y
u
q Series Name : HIF3H w No symbol : Standard
A : With mis-insertion preventive guide B : Similarly, guide position center 1 point type for 50, 60 and 64 contacts e Number of contacts : 4, 6, 8, 10, 12, 14, 16, 18, 20, 24, 25,
26, 30, 34, 40, 50, 60, 64, 70, 130 r Contact alignment: D: double rows
S: single row t A : Straight selective gold plated
B : Right angle selective gold plated y Contact pitch : 2.54mm u Contact type
Part Number
CL No. Number of Contacts A B
Part Number
HIF3HA- 6DA-2.54DSA 618-0139-8
6
8.62 5.08 HIF3HA-30DA-2.54DSA6
HIF3HA-10DA-2.54DSA 618-0101-5
HIF3HA-30DA-2.54DSA
qPin Header qSocket
HIF3H - * P B - 2.54 DSA
q
w er
t
y
q Series Name : HIF3H
w Number of contacts : 4, 6, 10, 12, 14, 16, 20, 24, 26,
30, 34, 40, 50, 60, 70, 130
HIF3HA-60DA-2.54DSA
HIF3HA-24DA-2.54DSA 618-0113-4
24
31.46 27.94 HIF3HB-60DA-2.54DSA
HIF3HA-26DA-2.54DSA 618-0105-6 HIF3HA-26DA-2.54DSA 618-0125-3
HIF3HA-64DA-2.54DSA
DS: Right angle type DSA: Straight type DSB: Right angle for flexible board DSC: Straight for flexible board
A111
元器件交易网 sReceptacle Straight Through hole Type
26
34.02 30.48
HIF3HA-64DA-2.54DSA
HIF3HB-64DA-2.54DSA
sReceptacle Straight Through hole Type
CL No. 618-0106-9 618-0126-6 618-0107-1 618-0127-9 618-0108-4 618-0128-1 618-0109-7 618-0129-4 618-0131-6 618-0110-6 618-0130-3 618-0132-9 618-0112-1 618-0134-4 618-0133-1
e
P
: Pin header
r Contact material A: Phosphor bronze (DS: brass)
B: Brass
t Contact pitch : 2.54mm
y Contact type
DS : Right angle type
DSA : Straight type
W : Wrapping type
20
51.8 48.26
25
64.5 60.96
A112
元器件交易网 sReceptacle Right Angle Through hole Type
Part Number HIF3H- 4DB-2.54DS HIF3H- 8DB-2.54DS HIF3H-10DB-2.54DS HIF3H-12DB-2.54DS HIF3H-14DB-2.54DS HIF3H-16DB-2.54DS HIF3H-16DB-2.54DSB
元器件交易网
2.54mm Pitch Board to Board Connector
HIF3H Series
sFeatures
1. Product Variation
Afford to connect the board to board horizontally or vertically.
Pin header
DS DSA
Material PBT
Phosphor bronze
Brass or phosphor bronze
Finish Black Selective gold plated
Selective gold plated
Remarks UL94V-0
–––––––
A110
元器件交易网 sOrdering Information
sProduct Specifications
Rating
Current rating: 2A
Operating Temperature Range: -30 to +85ç (Note 1) Storage Temperature Range: -10 to +60ç(Note 2)