MQ-W系列反射型距离传感器产品说明说明书
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
* Original Sensor
40.131For 40 mm .131 ft.For 30 mm .098 ft.For 20 mm .066 ft.Operating range (mm)Moving direction Standard target (white drawing paper 10×10 mm .394×(m m )(
f t
.
)O p e r a t
i n g d i s t a n
c e 30.09820.06610.39410
.3945.1975.1970200 .656150.492100.32850.164For 150 mm .492 ft.
For 200 mm .656 ft.
For 100 mm .328 ft.For 50 mm .164 ft.Operating range (mm)Moving direction Standard target
(white drawing paper 2020 mm .787×.787 inch (m m )(f t
.)O p e r a t
i n g d i
s t
a n c
e 10.39410
.3945.1975.1970200 .656600
1.9694001.312For 500 mm 1.641 ft.For 700 mm
2.297 ft.
For 300 mm .984 ft.
Operating range (mm)Moving direction
Standard target
(white drawing paper 75 75 mm 2.953×2.953 inch (
m m )(f
t .)
O p e r a t i n
g d i
s
t
a
n c
e
10.394
10
.3945.1975.19702.Projector beam diameter characteristics Light beam diameter is determined as the region where the amount of light is decreased to 1/e 2.72) when the largest amount of light is assumed as 1.
MQ-W3 types MQ-W20 types MQ-W70 types
(mm inch 2.5 dia..098 2.3 dia..091 4.0 dia..157(mm ft.20.06630.09840.131
0 6.9 dia..2726.7 dia..2647.4 dia..2918.3 dia..327(mm ft.100.32850.164150.492200.6560inch 23.0 dia..90633.0 dia.1.29939.0 dia.1.535(mm ft.)300.9895001.6417002.28703 Detectable target characteristics
MQ-W3 types 4.Material characteristics
Comparision between MQ-W20A and former product
Condition: Target (40i 60 mm 1.575i 2.362 inch ),
target assumed as natural shape
For the former product (diffuse reflective type),
depending upon the object material, the operating range varied greatly, but for the triple beam type there a little variation.100.01520.06630.09840
.13101000.155Distance setting 40 mm .131 ft.Distance setting 30 mm .098 ft.Distance setting 20 mm .066 ft.Target size (mm 2 inch 2)D i s t a n
c e r a n g e (
m m f t
.)Standard target (white drawing paper 10×10 mm .394×.394 inch )100.328200.656300.9844001.1325001.6416001.969Distance range (mm ft.) × : Impossible Former pruduct White drawing paper Corrugated carton Veneer panel Black rubber ××Triple beam type (MQ-W20A)10.03320.06630.09840.131Distance range (mm ft.)White drawing paper Black drawing paper Corrugated paper Veneer panel Black rubber N o n -g l
o s s y t a r g e t S e m i
-g
l
o s s y t a r g e t G l
o s
s y t a
r
g e t Mirror Blue acrylic White acrylic Copper clad printed circuit board 50.164100.328150.492200.656Distance range (mm ft.)
White drawing
paper
Black
drawing
paper
Corrugated
paper
Veneer panel
Black rubber
N
o n
-
g l o
s s
y
t
a
r g e t
S e
m i -g l o s
s
y
t
a
r g
e
t G
l o s
s
y
t a r g
e
t
Mirror
Blue acrylic
White acrylic
Copper clad
printed circuit
board
10001.55100.328200.65601000.155Distance setting 200 mm .656 ft.Distance setting 100 mm .328 ft.Distance setting 40 mm .131 ft.Target size (mm 2 inch 2)D i s t a n c e
r a n g e (
m m f
t .)
Standard target (white drawing paper 20×20 mm .787×.787 inch )1,0001.55100
.328200.656300
.984400
1.3125001.6416001.969700
2.297010,00015.5
Distance setting 700 mm
2.297 ft.
Distance setting 400 mm 1.312 ft.
Distance setting 200 mm
.656 ft.Target size (mm 2 inch 2)
D i
s t
a
n
c
e r
a
n
g e
(
m
m
f
t
.)
Standard target (white drawing paper 75×75 mm
2.953×2.953 inch )
MQ-W3 types Condition: Target (40i 60 mm 1.575i 2.362inch ), natural shape MQ-W20 types Condition: Target (40i 60 mm 1.575i 2.362inch ), natural shape
CONNECTING DIAGRAM Make connection to B side with pink wire for
Light ON Make connection to v side with pink wire for Dark ON Note: When switching a power source, make ground connection to the frame ground termi-nal or to the ground terminal. This will assure
more stable operation.Output tran-sistor Operation
indicator LED Operating condition
With light
intercepted ON
With light entering ON
Common use
Lights with light entering
12.2.48011.7.461 3.3
.1302,000
78.
743.3.130 3.3
.130 4.4
.173 4.4.173
44.8
1.76424
.94510.9.4291.4
.0554
.15716.6.65425.41 inch 4.157 2.2
.08710.7.421
6.3
.2487.3.28724.4(1 inch)(17)(.669)
25.4±0.2
1 inch 25.4±0.21 inch 6.3.248321.2606.3 .248
1.039
4.2 DIA..16512.6.496Distance adjustment dial Operation indicator LED 2-M4 (P = 0.6) tapped
M.S.:* M4 or #6Adjustment indicator LED 12.2.4803.3.1302
,00078.
743.3.130 3.3
.130 4.4
.173 4.4
.17344.8
1.76424
.94510.9.429
1.4.0554
.15716.6
.65425.41 inch 4.157 2.2
.08710.7.421
6.3
.2487.3.28724.4(1 inch)(17)
(.669)
25.4±0.2
1 inch
25.4±0.21 inch 7.5
.2957.5
.29510.5.413321.2601.039 4.2 DIA..16512.6.496Distance adjustment dial Operation indicator LED 2-M4 (P = 0.6) tapped M.S.:* M4 or #6Adjustment indicator LED Dimensions with the mounting bracket**
attached
Outline dimensions 18.2.7172,00078.
743.5.1383.5.138 3.5.138 4.4
.173 4.4.1734
.157
68.22.68512.5
.492
12.5.492
24
.945
12.4.4881.6
.063
17.4.68536.61.44145
1-49/6445.01.77212.7
.500 4.5 DIA..1779.1.3588.1
.319
44(1-3/4 inch)(22)
(.866)
45±0.21-49/6445±0.2
1-49/64
13.51213.51215.5.61052
2.0471.039 4.2 DIA.
.165
18.6.732Distance adjustment dial Operation indicator LED 2-M4 (P = 0.6) tapped M.S.:* M4 or #6Adjustment indicator LED Dimensions with the mounting bracket**attached
Outline dimensions General tolerance:
General tolerance:
General tolerance:
*M.S.: mounting screw **The mounting bracket is enclosed in the inner carton.
Fig. 1 Optical triangulation range measurement method Other examples of this method are
the automatic focusing and camera
range measurement systems.
Fig. 2 Triple beam range measure-ment method By averaging the range measure-ment signals of the 2 light receiving systems, the range measurement
difference is cancelled.
Fig. 4 PSD (position sensitive device) construction By making a calculation of the ratio of I 1and I 2, the light spot position Fig. 3 Light beam trace of the lens (a) is a spherical lens, and (b) is the aspherical lens. Because there is no aberration in (b), range measure-ment precision is high.Fig. 5 Signal processing circuit block diagram
5) Avoid using in a location with high concentrations of steam, dust, or corro-sive gas.
6) The sensor is of immersion protected type, but this does not mean that it can be used in water or where there is direct impingement of rain for detecting objects.
2.Connections。