高层建筑给排水毕业设计

合集下载

高层给排水专业毕业设计论文

高层给排水专业毕业设计论文
通过本工程项目设计,本人不但掌握了高层建筑的给水、排水、消防工程等设计的设计要点和设计内容,同时对工程制图有了更扎实的基本功。
关键词:给水工程;排水工程;消防工程
Weinan dalixian big li hotel water project preliminary design
A
This designed project is the design of the water supply system, drainage system and fire fight system of the hotel building inWinancity. The building lies inWeinancity, is a hotel, catering, bathhouse and the office of integrated tall buildings. its buildings, the total 83.2,3272.16m2for the building on the 25 floor. the ground floor, the ground floor is the pump, and the floors are the main dining room, bathhouse and the office,3 to the 25floor is the hotel.
To the building of the drainage system to adopt any drainage consummated in the hotel bathroom floor drains ( technology on the mezzanine ) after.
This design the system and system settings, and shrunk from life to the hydrant spraying system of common design. hydrant system arrangement : guarantee of three into the water pump ( in water, with the pump water and clear the automatically shrunk ). spraying system: set out in6wet check to ensure that the police,3shares into the water at the same time, we must ensure that all into the water is wet in the valves. in this project before the project design, i gain not tall, drainage and shrunk。

建筑给水排水设计案例(某学生给排水毕业设计)

建筑给水排水设计案例(某学生给排水毕业设计)

前言随着我国国民经济的增强和发展,人们生活水平的提高,小区和高层建筑的不断兴起,使得建筑给水排水得到了不断的拓宽和深化,应用越来越广,同时人们对于给水排水方式提出了更高的要求。

高层建筑给水排水设备的使用人数多与少,瞬时给水量和排水流量的可靠性,以及经济合理的给水排水系统形式及妥善处理排水管道的通气问题,保证供水安全可靠、排水通畅和维护管理方便……这些都与多层建筑和低层建筑有着很大的差别。

高层建筑给水排水工程与一般多层建筑和低层建筑给水排水工程相比,其基本理论和计算方法在某些方面是相同的,但因高层建筑层数多、建筑高度大、建筑功能广、建筑结构复杂,以及所受外界条件的限制等,高层建筑给水排水工程无论是在技术深度上,还是广度上,都超过了低层建筑物的给水排水工程范畴。

本设计针对沈阳市和平区新兴办公楼,严格遵循规范要求的基础之上,吸收新的技术,新设备,新观念及新的设计方法制定了设计方案,使设计更加贴近实际生活。

1 生活给水系统设计与计算1.1 生活给水系统方案由于本设计楼层较高,若只采用一个给水系统供水,低层的配水点所受的静水压力很大,易产生水锤,损坏管道及附件,流速过大产生水流噪音;低层压力过大,开启水龙头时,水流喷溅严重,使用不便。

根据建筑给排水设计手册上卫生器具的最大静水压力不得超过0.35MPa[]1。

设计考虑到本设计对象是16层的高层建筑。

市政管网提供的压力不能全部直接供水,故必须对生活用水进行提升或加压,一般高层建筑设计可以采用变频水泵(方案一)或使用高位水箱,水泵-水箱供水(方案二)。

本设计考虑到方案设计的合理性并结合设计的具体实际对两方案进行了比较,见表1-1。

表1-1 方案比较Table1-1 Program Comparison方案方案一方案二方案简介市政管网的水引至地下室生活水池,由变频水泵供水或直接由变频泵接市政管网供水,为下行上给式。

市政管网的水引至水池,由恒速水泵提升至水箱供水,水泵-水箱联合供水,为上行下给式。

建筑给排水毕业设计开题报告

建筑给排水毕业设计开题报告

建筑给排水毕业设计开题报告建筑给排水毕业设计开题报告1一、课题要求及工程概况1、设计原始资料本次毕业设计的题目是:河北省某高校高层建筑—图书馆给水排水工程设计(1)工程概况本工程所在地秦皇岛市,为高层图书馆,建筑面积14726m。

本楼设地下一层,地上九层,楼内设有电梯2部,供客人乘坐,其中一部为消防电梯。

地下室内可布置水池、水泵等贮水和升压设备。

地下一层4.20米(含500覆土),首层—九层3.90米;顶层5.50米。

室内外高差0.75米,室外地坪至檐口高:36.85米。

本工程为钢筋混凝土框架结构。

环绕该楼有校区的DN200低压生活给水管道,管顶埋深1m,常年可靠给水压力0.2MPa。

该市建有生活污水处理厂,污废水分流排放。

污废水管道均为DN500,管道埋深标高-2.5m。

冰冻线深度0.7m。

城市可提供一路独立电源。

(2)建筑图纸总平面图,地下室平面图,建筑首层平面图,建筑二层平面图,建筑标准层平面图,屋顶平面图,电梯机房、水箱间平面图,卫生间大样图,剖面图。

2、设计任务与内容(1)建筑内部生活给水系统设计;(2)建筑内部消防系统设计;(3) 建筑内部排水系统设计;二、课题研究的目的和意义随着我国经济的飞速发展,科学技术的告诉进步,国民生活水平不断提高。

建筑业也向高层化、人性化发展。

高层建筑是指十层及十层以上的居住建筑(包括首层设置商业网点的住宅),和建筑高度超过24米的公共建筑、工业建筑,100米以上的建筑高度的为超高层。

本课题中图书馆室外地坪2至檐口的高度为36.85米,属于高层建筑。

与一般多层建筑给水排水工程相比,高层建筑给水排水在基本理论和计算方法等方面是相同的。

但高层建筑在构造上层数多、建筑高度大、建筑功能广、建筑结构复杂、所受外界条件限制等,使其给排水工程更加复杂。

因此高层建筑的给排水设计除了要满足水量、水压、水质的要求外,还要解决高层因建筑高度过高而引起的水锤、震动、噪声和渗漏等问题。

毕业设计(论文)-某高层办公楼给排水工程设计【全套图纸】 模板

毕业设计(论文)-某高层办公楼给排水工程设计【全套图纸】 模板
2、消除了地下水池的二次污染
传统的水池二次加压供水方式将自来水放入水池,水池的水易于被赃物甚至动物尸体所污染,尤其在夏天易产生藻类或滋生蚊虫,直接影响到用户的身体健康。该设备利用调节装置采用封闭式供水方式,消除了二次污染。
3、节省投资,减少占地,安装、使用、检修方便
建造水池,工程总投资大,并且使用过程中要定期清洗,不但增加了工程的总投资,还增加了日常的维护费用。该设备利用调节装置供水,节省投资,减少占地,根据用户的现场情况可以采用立式或卧式不同的安装方式,检修方便。
3.1.5.1 基本要求
(1)确保供水安全和良好的水力条件,力求经济合理
管道尽可能与墙、梁、柱平行,呈直线走向,力求管路简短,以减少工程量,降低造价。干管应布置在用水量大或不允许间断供水的配水点附近,既利于供水安全,又可减少流程中不合理的转输流量,节省管材。
引入管至少两条,宜从建筑物不同侧的两条城市管道上接入,在室内将管道连成环状或贯通状双向供水。若条件不能满足,可采取设贮水池(箱)或增设第二水源等安全措施。如果只能同侧接入,两根引入管之间的间距不得小于15m。水表节点设于引入管上。
合理的确定高层建筑给水系统的竖向分区,系到给水系统的运行、使用、维护、管理、投资节能等情况的效果,是高层建筑给水系统的首要环节。
该高层办公楼给水系统竖向分为2区,分为低区和高区:低区-1~6层和职工食堂由市政管网直接供水;高区7~14层给水需进行二次加压,高区采用无负压变频给水设备。
无负压变频给水设备原理:自来水管网的水直接进入调节罐,罐内的空气从真空消除器内排出,待水充满后,真空消除器自动关闭。当自来水能够满足用水压力及水量要求时,设备通过旁通止回阀向用水管网直接供水;当自来水管网的压力不能满足用水要求时,系统通过压力传感器(或压力控制器、电接点压表)给出起泵信号起动水泵运行。水泵供水时,若自来水管网的水量大于水泵流量,系统保持正常供水;用水高峰期时,若自来水管网水量小于水泵流量时,调节罐内的水作为补充水源仍能正常供水,此时,空气由真空消除器进入调节罐,消除了自来水管网的负压,用水高峰期过后,系统恢复正常的状态。若自来水管网停水而导致调节罐内的水位不断下降,液位探测器给出水泵停机信号以保护水泵机组。

十五层商住高层建筑给水排水毕业设计优秀

十五层商住高层建筑给水排水毕业设计优秀

关键词:高层商住楼;给水系统;消火栓系统;自动喷水灭火系stract
Abstract
This construction was a 15 layers buildings of the high-level composite commercial / residential buildings,the construction was the second category building with a total height of 46.6 meters.one to two floors are the star market,basement and garage equipment for the space.3-15 of the residential tower. The water supply and drainage projects was designed in this paper includeing water supply system,fire safety system,drainage system and Stormwater system.Water system carried on the devided region water supplyment in which municipal pipe network water supply directly in low-use areas and combined the pool and cisterns as well as high-water-pump to supply watert in hign-use areas.Fire system included fire hydrant system and automatic sprinkler system.The drainage adopted a confluence system,stormwater used the way of gravity drainage so that the roof rainwater was discharged in time.Besides,it included the introduction of water pipes,and the transportion of the discharged water to outdoor septic tanks,storage tanks,the pumps,high water tanks as well as other designs. The design of the water supply dry riser pipe and steel are used Lining Plastic composite pipe (hydraulic calculation of the plastic pipe),the other branch of the PPR are used;fire hydrant pipes used to heat galvanized steel pipe,automatic sprinkler system pipes used both inside and outside wall Hot galvanized steel pipe;drainage pipe using PVC drain pipes (UPVC),hydraulic calculation of the plastic pipe.

给排水工程毕业设计论文-高层住宅给排水设计

给排水工程毕业设计论文-高层住宅给排水设计

1 引言随着近几年来建筑业的飞速发展,高层建筑不断涌现。

新增的高层建筑中,住宅楼所占比例逐渐增多。

而随着人们生活水平的提高,人们对生活质量的要求也越来越高,给排水设计中,在系统的安全性、耐用性以及服务质量等方面需要注意的问题也越来越多。

本工程结合了工程所在地石家庄的实际情况,针对住宅的使用对象以及给排水专业的新技术、新规范、新动态,各系统设计充分考虑了用水安全、经济耐用,节能环保等方面的要求,将本住宅按高级住宅标准设计,同时考虑各系统的服务质量工程建设的经济效益与社会效益。

可谓是是高标准,严要求,以期在完成毕业设计的同时,使自己充分掌握给排水设计知识与技巧,充分了解本专业的发展趋势。

2 工程概况本设计为本科阶段毕业设计,设计题目来源于实际工程,是某企业的一栋宿舍楼,工程地点在石家庄市,为二类高层建筑。

基本设计参数包括:(1)建筑物性质:普通高层住宅楼1座;(2)建筑层高:总高49.3m,地上17层,地下2层;(3)供水水源:来自市政供水管网。

另有条件图一份,内有地下二层、地下一层、首层、标准层、顶层、屋顶建筑平面图,见条件图。

3 设计计算说明书3.1 室内给水系统的设计计算设计要点:(1)系统选择依据《建筑给排水设计规范》GB50015-2003,高层建筑生活给水系统的竖向分区,应根据使用要求,材料设备性能,维修管理,建筑物层数等条件,结合室外给水管网的水压经经济技术比较确定。

住宅楼竖向分区各分区最低卫生器具配水点处的静水压不宜大于0.45MPa,特殊情况下不宜大于0.55MPa;水压大于0.35MPa的入户管(或配水横管),宜设减压或调压设置;各分区最不利配水点的水压,应满足用水水压要求。

建筑高度不超过100m 的建筑的生活给水系统,宜采用垂直分区并联供水或分区减压的供水方式。

本设计中,石家庄市市政管网可提供的常年资用水头为0.30MPa ,可以满足六层高的用水压力,经技术经济比较,在本楼采用上下分两区的给水方式,下区六层由市政管网供水,下行上给式,7~17为上区,由水箱供水,上行下给式,屋顶水箱间设有一座17 3m 的水箱(其中有消防用水量12 3m ),为上区供水。

毕业设计---十六层酒店的建筑给排水工程设计

毕业设计---十六层酒店的建筑给排水工程设计

毕业设计说明书题目:长沙某酒店给水排水工程设计学院(直属系):能源与环境学院年级/专业/班:学生姓名:学号:指导教师:完成时间:2010年月日目录摘要 (4)前言 (5)第一部分设计依据及设计任务 (6)1设计依据 (6)2设计任务 (7)第二部分方案设计说明书 (8)1给水工程设计 (8)1.1 给水系统的组成 (8)1.2 给水管道布置和敷设 (8)1.3 设计方案的比较 (9)1.4 给水管道设备安装要求 (10)2消防工程设计 (11)2.1 消火栓消防工程设计 (11)2.2 自动喷淋灭火系统设计 (14)2.3 消防水箱及消防贮水池 (16)2.4 消防管道设备安装要求 (16)3热水工程设计 (17)3.1 热水的供应系统选择 (17)3.2 热水供应系统的组成 (18)3.3 热水系统定额 (18)3.4 主要设备 (18)3.5 热水管道设备安装要求 (19)4排水系统 (19)4.1 排水系统的选择 (19)4.2 排水系统的组成 (19)4.3 检查口、清扫口和检查井的设置 (19)4.4 排水管道设备安装要求 (20)第三部分设计计算书 (21)1室内给水系统计算 (21)1.1 用水量计算 (21)1.2 设计秒流量公式 (23)1.3 室内所需的压力 (24)1.4 地下室加压水泵的选择 (28)1.5 生活贮水池容积的计算 (28)1.6 高位水箱容积的计算 (29)1.7 室外环网计算 (29)2消防系统的计算 (30)2.1 消火栓给水系统计算 (30)2.2 自动喷淋给水系统计算 (34)3建筑内部热水系统计算 (40)3.1 热水量 (40)3.2 耗热量 (41)3.3 加热设备选择 (41)3.4 热水配水管网计算 (41)3.5 热水回水管网的水力计算 (43)3.6 选择循环泵 (45)3.7 蒸汽管道计算 (46)3.8 锅炉选择 (46)4室内排水系统计算 (46)4.1 排水方式的选择 (46)4.2 排水系统水力计算 (46)4.3 室外排水管道计算 (52)4.4 化粪池计算 (52)5雨水排水系统计算 (53)5.1 雨水量计算公式 (53)5.2 屋面雨水系统计算 (54)5.3 室外雨水系统计算 (54)结论 (56)总结和体会 (57)致谢 (58)参考文献 (59)摘要本设计是长沙市十六层酒店的建筑给排水工程设计,本酒店总占地面积3800m2,建筑面积为23697.48m2,建筑高度59.6m,地下一层为车库,地上1~5层为餐饮娱乐、会议等公共活动用房,6~16层为宾馆客房。

高层给排水专业毕业设计开题报告

高层给排水专业毕业设计开题报告

榆林学院毕业设计开题报告题目渭南市大荔县大荔宾馆给水排水工程设计学生姓名学号院 (系)专业指导教师报告日期2011 年3 月12 日毕业设计题目渭南市大荔县大荔宾馆给水排水工程设计题目类别(请在有关项目下作√记号)设计论文其它√题目需要在实验、实习、工程实践和社会调查等社会实践中完成是否√毕业设计起止时间2012年 3月 5 日起至 2012年 6月8日(共 14 周)一、毕业设计课题渭南市大荔县大荔宾馆给水排水工程设计二、毕业设计的意义和任务毕业设计是学生在学完教学规定的各门课程后所必须进行的最后的也是极为重要的实践性教学环节。

毕业设计的作用是综合运用所学的基本理论、基本知识及基本技能,培养独立分析和解决工程实际问题的能力。

毕业设计可使学生得到以下几方面的锻炼:1、设计技能;2、综合运用各种理论知识来解决工程问题的能力;3、贯彻党和政府在基本建设方面的各项方针政策的能力。

三、毕业设计要求通过设计学生应具备有:对给定基础资料进行分析及一定的文献查阅的能力;一定的方案、综合技术经济分析比较能力;一定的理论分析与设计运算能力及应用计算的能力;工程制图及编写说明的能力。

学生在教师的指导下独立地、全面地完成设计任务中规定的任务,并要求努力提高设计质量,具体要求如下:1、设计过程中必须独立完成设计、计算和绘图工作,认真提出设计文件;2、设计的每一阶段完成后,必须经指导老师审批后才能进行下一阶段的设计;3、各阶段设计必须严格按照计划进行定期完成;4、设计文件经指导老师审查,考查及格后,再做毕业设计答辩,以此定为高等学校结业和质量检查。

四、毕业设计内容大荔宾馆是根据上级部门批准而拟建的一幢25层钢砼框架结构(一、二级耐火等级)建筑。

建筑总高度为 83.2米,建筑面积3272.16平方米,各层设置情况详见建筑分层平面图。

底层为地下室,层高为6 米;一至二层为多功能层,层高为 5 米; 3-25 层为标准层,层高为 3.2 米;技术层设在第13-14层之间,层高为3米;室内外高差为1米。

高层住宅楼给水排水消防系统 设计_本科毕业论文设计说明书

高层住宅楼给水排水消防系统 设计_本科毕业论文设计说明书

(此文档为word格式,下载后您可任意编辑修改!)摘要根据题目要求设计了17层高层综合楼的建筑给水系统、建筑排水系统、建筑消防系统(消火栓给水系统及自动喷水灭火系统)、建筑屋面雨水排水系统设计。

给水系统采用分区供水,低区负一到三层,由市政管网直接供水;中区四到十一层;高区十二到十七层。

中区和高区采用无负压变频供水。

排水系统采用污、废水合流制,底层单独排放,排水立管设伸顶通气管,污水经化粪池处理后排向市政污水管网。

消防系统分消火栓给水系统和自动喷水灭火系统。

屋面雨水排水系统采用檐沟内排水。

关键词:高层建筑;给水系统;排水系统;消防系统ABSTRACTBaised on the synthesis analysis, the water supply system, the drainage system, fire system(fire block. The floors from the negative to the third are the low areas, water of which is supplied directly by the municipal pipe network. The floors from the 4th to the 11th are the middle areas and the floors from the 12th to the 17th are the pump group. The drainage system is an interflow system of sewerage and waste water. Water of the first floor drains separately, the upright draining pipes are equipped with the ventilating pipes, and then the sewerage is disposed by the septic tanks and drains to the municipal waste pipe network. The fire system includes the fire outside drainage system.Key Words: ;wastewater system;fire system目录第一章引言 (1)第二章工程概况及设计任务 (2)2.1设计题目 (2)2.2目的和作用 (2)2.3设计原始资料 (2)2.4工程概述 (3)第三章建筑给水系统 (4)3.1给水系统方案的确定 (4)3.1.1 水源情况 (4)3.1.2 用水量 (4)3.1.3 分区和供水方式 (4)3.1.4 给水管材 (5)3.1.5 管网形式及敷设 (5)3.2管道的水力计算 (6)3.3生活贮水量计算 (18)3.4水表选型及水表水头损失计算 (18)3.5对室内管网所需水压进行校核 (19)3.6生活水泵的选择 (19)3.6.1 中区水泵的确定:(4~11层) (20)3.6.2 高区水泵的选择:(12~17层)............................................... 错误!未定义书签。

长春市某大厦高层建筑采暖给排水设计(毕业说明书)

长春市某大厦高层建筑采暖给排水设计(毕业说明书)
公式 (2-1)式中Q-维护结构基本耗热量,( W );
K-维护结构的传热系数,[W/(㎡•℃)];
tn-冬季室内设计温度,(℃);
a-温差修正系数;查手册a取1;
tw–采暖室外计算温度。
1.tn的确定:
卫生间:15℃地下室:10℃
消防控制室:18℃卧室:18℃
值班室:18℃楼梯间:16℃
起居厅:18℃浴室:25℃
千万不要删除行尾的分节符,此行不会被打印。在目录上点右键“更新域”,然后“更新整个目录”。打印前,不要忘记把上面“Abstract”这一行后加一空行
第1章设计任务
1.1
长春市永辉大厦高层建筑采暖、给排水设计。
1.2
1.2.1
1)永辉大厦为综合性的建筑,建筑物的功能有地下室、人材市场、综合市场、餐厅、客房等,总建筑面积为2.11万m2。
厨房:16℃储藏间:10℃
2.tw的确定:
根据我国现行的规范采用历年平均不保证5天的日平均温度,长春市冬季室外采暧温度:tw=-23℃。
3.地带K值的确定:
由暖通空调·动力技术措施查得:地带K值的划分,直接铺设在土壤上、地面各构造层材料的导热系数 W/(m•℃)的非保温地面,应平行于外墙、从外向内、每2m宽划分地带,并分别取传热系数为:
2)共有15层,楼高58m。
3)层高:地下室为4.2m,一、二层为5.1m,三、四层为4.8m,五层为2.2m,
六层至十五层高为3.6m
1.2.2
(1).外墙的选用:由手册选择:
1.水泥砂浆抹灰、喷浆2.砖墙
3.保温层采用聚苯板4.内粉刷加油漆
1)厚度: =370mm普通砖外墙
2)传热热阻R=1.07(m²•℃/W)
做中高区的给排水设计,给水分为一个区,给水进行下分式,对于底层的排水单独排出,给水管材使用PPR塑料管,排水管材使用UPVC塑料管。

高层建筑给排水毕业设计论文终稿

高层建筑给排水毕业设计论文终稿

XXXX大学20xx届本科毕业设计说明书X X X X X X毕业设计说明书作者:学号:学院:系(专业):题目:某小区高层住宅给排水工程设计指导者:评阅者:20XX 年X 月XX 日毕业设计中文摘要xxxxxxxxx给排水设计摘要:随着国民经济的快速发展,我国居民住宅的层数逐渐增多。

本设计为今年年底即将动工的xxxxxxxxx给排水设计。

本建筑为高层住宅,设计主要内容为室内建筑给水系统设计与计算、室内建筑排水系统设计与计算、室内建筑消火栓系统设计与计算、自动喷淋系统设计与计算,屋面雨水系统设计与计算。

该居民楼为地上26层,地下2层,地上部分为居住区,地下一层为储藏室,地下二层平时为地下车库,战时为人防区。

该住宅楼层数较多,所以采用分区给水的方式进行供水。

卫生间的排水方式为隔层排水,厨房则为同层排水,对于部分开放式阳台,则需要设置单独的排水立管。

消防系统分为消火栓灭火系统、自动喷淋灭火系统、灭火器灭火系统,其中自动喷淋只布置在地下一层储藏室和地下二层车库内。

屋面雨水系统采用普通外排水。

关键词:高层住宅协调结构图给排水设计毕业设计外文摘要Title Water Supply and Drainage Design of xxxxxxxxxAbstract:With the rapid development of the national economy,residential layers are also increasing.Water Supply and Drainage Design of xxxxxxxxxxx is about to start end of the year,the construction being high-rise residential.This is a high-rise residential buildings, designed mainly for the interior design and calculation of building water systems, interior architectural design and calculation of drainage systems, interior architectural design and calculation of fire hydrant system, automatic sprinkler system design and calculation, design and calculation of roof drainage systems.The residential building has 26-storey above ground and 2 underground floors,the ground part being the residential area,basement 1 being the storage room,basement 2 being the underground garage in peacetime,people's air defence in wartime.The number of residential floors is too much, so I adopt the way of district water supply.The drainage method of toilet is compartment drainage, and kitchen is same-layer drainage, as for part of the open terrace, need to set up a separate balcony drain standpipe.Fire system is divided into fire cock extinguishing system, automatic sprinkler systems, fire extinguisher system, while the sprinkler systems are only arranged in basement storage room and a ground floor garage.Roof rainwater drainage system use the ordinary outside drainage.Keyword:High-rise residential Coordination Structure drawing Water and drainage design目录1 引言 (1)2 设计任务及设计资料 (2)2.1设计任务 (2)2.2设计依据 (2)2.3市政给排水资料 (3)3 建筑给水系统设计与计算 (3)3.1设计说明 (3)3.2 设计计算 (4)4 建筑排水系统设计与计算 (25)4.1 设计说明 (25)4.2 设计计算 (26)5 建筑消火栓灭火系统设计与计算 (29)5.1 设计说明 (29)5.2设计计算 (30)6 建筑自动喷淋灭火系统设计与计算 (34)6.1设计说明 (34)6.2 设计计算 (35)7 建筑灭火器系统设计与计算 (40)7.1设计说明 (40)7.2设计计算 (41)8 消防水箱及消防水池设计与计算 (42)8.1设计说明 (42)8.2设计计算 (42)9 消防电梯集水坑设计与计算 (43)10 建筑屋面雨水系统设计与计算 (43)10.1设计说明 (43)10.2设计计算 (43)10.3雨水立管布置 (44)结论 (45)参考文献 (46)致谢 (47)附图1、2 设计说明附图3-15 建筑给水、排水、消防平面图附图16、17 屋面雨水平面图附图18-21 给水、排水、雨水、空调冷凝水、消防系统图1引言随着国家经济的发展,人们的生活水平也不断提高,建筑的理念也随之而发生了巨大的改变,从而旧的建筑标准和模式已渐渐不能满足现代人的居住需求。

建筑给排水毕业设计

建筑给排水毕业设计

建筑给排水毕业设计建筑给排水毕业设计,这话一说出来,好像有点让人心里发毛。

你想啊,大家都知道建筑是什么,大楼、商场、住宅区,咱们天天住、天天用的东西。

给排水嘛,顾名思义,就是给建筑提供水、排走脏水的工作。

说白了,这就是让咱们在楼里过得舒服,让水流得通畅,厕所不堵,洗澡有水,厨房能顺利做饭的关键所在。

要说毕业设计,唉,那可真的是一项“重任”啊!一方面要有技术含量,一方面要有创意。

反正对我来说,做这个设计简直就是一场智力大爆发。

一开始我也有点懵,不知道从哪里入手。

看着满纸的设计要求,心里想:“我去,这么复杂?”不过慢慢的,发现其实这个东西并没有那么吓人。

只要你理清楚了思路,很多问题就迎刃而解了。

比如说,水管的布置,简单的说就是把水从哪里引过来,流到哪里,怎么让水流得又快又好。

就像你家厨房洗菜池的水管,别看它简单,实际上有讲究呢。

管道一不小心布错了,那可真的是麻烦了。

就像你心情不爽,打电话给朋友,偏偏他手机没电,一通电话打出去半天没人接,气不气?再说到排水,哎呦,这个真是关键了。

你想啊,排水不畅,整个建筑简直就像个大漏水的桶。

厕所一堵,谁受得了?你洗澡,水管不通,积水满地,简直就是恶梦一场。

排水系统如果设计不好,不仅是生活质量大打折扣,严重了还可能出现楼层渗水,墙壁开裂,房子整体的结构安全都可能受到影响。

所以啊,给排水的设计不能大意,得从头到尾都认真算计。

就像你去买手机,不能只看外表,要看看系统能不能流畅,卡不卡。

你用了几个月之后就知道,手机到底值不值得买。

在毕业设计中,除了设计水管、排水管道这些硬核技术,咱们还得考虑一些更“软”的东西,比如说管道的材质。

你想啊,材质不好,管道容易老化,水流不畅就会影响整个系统的运行。

大家都知道,水是生命之源,但水管要是质量差了,那也是麻烦一大堆。

想想你早晨洗脸的时候,水管发出“咯咯”的声音,哎呦,真是烦死了。

再比如,夏天的时候,热水管如果没做好隔热,温度太高,容易把管道给“烤”坏,结果一开水龙头就冒热气,吓得你连忙收回手,好像一只烫到的虾一样。

建筑给水排水毕业设计

建筑给水排水毕业设计

摘要本设计的建筑为十八层的办公综合楼,给排水工程设计包括了建筑给水系统设计,建筑排水系统设计,消火栓系统设计,自动喷淋灭火系统设计。

建筑给水系统分为室内冷水系统和室内热水系统,其中室内冷水系统分为三个区:地下室至四层为低区,采用市政给水管网直接供水;四层至十二层为中区,采用中区变频泵组供水;十三至十八层为高区,采用高区变频泵组供水。

室内热水系统采用局部热水供应系统。

本建筑为一类高层民用建筑,而其建筑高度≥54m,建筑物火灾危险等级为中级危险Ⅰ级。

室内消火栓用水量和室外消火栓用水量分别取20L/s 和40L/s,火灾持续时间为3h,自动喷淋系统计算用水量为22.46L/s,火灾持续时间为1h,消火栓系统和自动喷淋系统前十分钟灭火用水由屋顶水箱提供,屋顶设增压与稳压设备。

排水系统采用污废分流制,污水立管采用双立管排水系统,设专用通气管,废水立管采用单立管排水系统。

给水系统均采用PP-R给水管材,消火栓给水系统和自动喷淋灭火系统采用内外热镀锌钢管,排水系统管材采用UPVC排水管。

在地下层设贮水池和加压泵房,地下室另设集水坑,集水坑中设潜污泵,保证污水及时排出。

关键词:建筑给水排水消防喷淋AbstractThe design of the building for 18 storey office building, to the drainage design of the project include the design of building water supply system, design of building drainage system, the design of fire hydrant system, automatic sprinkler fire extinguishing system design. Building water supply system water system and the life hot water system, which life water system is divided into three zones: basement to four layer for low area, the direct supply of municipal water supply pipe network; four to 12 storeys for the Central District, the central variable frequency pump water; thirteen to eighteen layers for high by high frequency pump water. Local hot water supply system for domestic hot water system. The building is a high-rise building, and the building height is more than 54m, the building fire danger level is extremely dangerous in grade I. Indoor fire hydrant water and outdoor fire hydrant water were taken 20L / s and 40L / s, fire duration 3h, automatic sprinkler system calculating water consumption 22.46L/s, fire duration for 1h, before the fire hydrant system and automatic sprinkler system ten minutes fire fighting water is provided from the roof tank roof design pressurization and pressure stabilizing device. Sewage drainage system uses sewage diversion system, sewage riser using double riser drainage system, dedicated aeration pipe, wastewater riser using single riser drainage system. Water supply system are PP-R water supply pipe, fire hydrant system and automatic sprinkler fire extinguishing system inside and outside the hot galvanized steel pipe, drainage pipe using UPVC drainage tube. In the underground layer design storage tank and pump pressure, underground chamber and the other set puddle, set a puddle in the submersible sewage pump to ensure timely discharge of sewage.Keywords: building Supply water drainage Fire control Spray目录摘要 (iii)Abstract (ii)第1章设计资料 (1)1.1 建筑设计原始资料 (1)第2章建筑给水系统的设计和计算 (2)2.1 室内冷水系统的设计 (2)2.1.1 室内冷水系统方案的确定 (2)2.1.3 冷水管材及管道设备方案安装要求 (5)2.2 室内热水系统的设计 (7)2.2.1 室内热水系统方案的确定 (7)2.2.2热水管材及管道设备安装要求 (9)2.3 室内冷热水系统计算 (11)2.3.1 用水量计算 (11)2.3.2 水池、水表的计算 (12)2.3.3 冷热水管网水力计算 (13)2.3.4 校核与选泵 (24)2.4热水系统计算 (27)2.4.1 热水用水量计算 (27)2.4.2 耗热量计算 (27)2.4.3 热损失计算 (28)2.4.4 热媒耗量计算 (28)2.4.5加热设备的选择和计算 (29)第3章建筑排水系统的设计与计算 (31)3.1 排水系统的设计 (31)3.1.1 排水方案的确定 (31)3.1.2 污废水排水系统类型的确定 (31)3.1.3 系统组成 (32)3.1.4 排水管材与管道布置敷设要求 (33)3.2 排水系统的计算 (38)3.2.1 设计秒流量公式的选用 (38)3.2.2 室内排水管道水力计算 (39)3.2.3 通气管管径的确定 (50)第4章消火栓系统的设计与计算 (51)4.1消火栓系统的设计 (51)4.1.1 室外消火栓系统布置要求 (51)4.1.2 室内消火栓系统布置要求 (52)4.1.3室内消火栓系统布置 (56)4.2消火栓系统的计算 (57)4.2.1 消火栓系统用水量 (57)4.2.2 消火栓系统的水力计算 (57)4.2.3 消防水箱 (61)第5章自动喷水灭火系统的设计与计算 (63)5.1自动喷水灭火系统的设计 (63)5.1.1 自动喷水灭火系统的布置要求 (63)5.1.2 自动喷水灭火系统类型的确定 (63)5.1.3 系统的组成 (64)5.1.4系统自动喷水灭火系统技术参数的组成 (64)5.1.5自动喷水灭火系统设计 (65)5.1.6 喷头选择 (65)5.2自动喷水灭火系统计算 (66)5.2.1 设计计算基本参数 (66)5.2.2 自动喷水灭火系统的水力计算 (66)参考文献 (71)致谢 (72)第1章设计资料1.1建筑设计原始资料图纸资料:建筑所在地总平面图,建筑底层平面图、首层平面图、二层平面图、标准层平面图、顶层平面图等。

优秀建筑给排水毕业设计【范本模板】

优秀建筑给排水毕业设计【范本模板】

前言本设计的主要任务是驻马店市世纪城公寓综合楼给水排水设计。

这是一栋18层的综合楼。

地下两层为停车场和设备间,地上1、2层为商场,其他部分为公寓。

每套公寓均设有卫生间,内设有坐式大便器、淋浴、洗脸盆各一个。

1,2层商场设有公共卫生间.各层建筑面积不同,地下室层高为3.9m和3.6m。

1,2层层高为5.1m,3至18层层高为3。

1m,建筑总高度为66m.根据建筑物性质、用途及建筑单位要求,室内设有完善的给水排水卫生设备系统,安全可靠的消防给水系统,设置独立的消火栓系统及自动喷水系统,每个消火栓箱内设按钮,消防时直接启动消防泵,生活水泵自动启动.本综合楼内的宾馆要求室内热水供应采用全天全循环集中热水供应。

本设计说明书包含建筑工程设计中的生活给水,排水,热水以及消火栓和自动喷水等设计项目.主要内容包括生活给水系统的设计计算、消火栓给水系统的设计计算、喷淋系统的设计计算、生活污水排水系统的设计计算。

prefaceThe main task of this design is in the center of the city, jiangsu province, including water supply and drainage design of the hotel。

This is a complex 26 house floor。

1 to 3 layers for the complex building subsidiary recreation,4 to 26 floors for hotel guest rooms。

The rooms and suites are equipped with toilet,ther are seated toilets,bathtubs,sinks in each one。

Layer construction area is different, the basement height is 4。

某高层建筑给排水毕业设计_secret

某高层建筑给排水毕业设计_secret

目录第一章室内冷水系统 (3)一竖向分区 (3)二用水量标准及计算 (3)三冷水管网计算 (4)四引入管及水表选择 (9)五屋顶水箱容积计算 (10)六地下贮水池容积计算 (11)七生活水泵的选择 (11)第二章室内热水系统 (12)一热水量及耗热量计算 (12)二热水配水管网计算 (12)三热水循环管网计算 (15)四循环水泵的选择 (16)五加热设备选型及热水箱计算 (17)第三章建筑消火栓给水系统设计 (18)一消火栓系统的设计计算 (18)二消防水泵的选择 (20)三消防水箱设置高度确定及校核 (20)四消火栓减压 (20)五消防立管与环管计算 (21)六室外消火栓与水泵接合器的选定 (21)第四章自动喷水灭火系统设计 (22)一自动喷水灭火系统的基本设计数据 (22)二喷头的布置与选用 (22)三水力计算 (22)四水力计算 (23)五自动喷水灭火系统消防泵的选择 (26)第五章建筑灭火器配置设计 (28)第六章建筑排水系统设计 (29)一排水管道设计秒流量 (29)二排水管网水力计算 (29)三化粪池设计计算 (33)四户外排水管设计计算 (34)第七章建筑雨水系统设计 (35)一雨水量计算 (35)二水力计算 (36)第一章 室内冷水系统一.竖向分区本工程是一栋十二层高的综合建筑,给水分两个区供给。

一、二、三层商场和办公室作为低区,由市政管网直接供水;三至十二层客房作为高区,由屋顶水箱供水。

二.用水量标准及用水量计算1.确定生活用水定额q d 及小时变化系数k h 。

根据原始资料中建筑物性质及卫生设备完善程度,按《建筑给水排水规范》确定用水定额和小时变化系数见下,未预见用水量高区按以上各项之和的15%计,低区按10%计。

列于用水量表中。

2.用水量公式:①最高日用水量 Q d =Σmq d /1000式中 Qd :最高日用水量,L/d ;m : 用水单位数,人或床位数;q d : 最高日生活用水定额,L/人.d ,L/床.d ,或L/人.班。

高层建筑给排水毕业设计计算书

高层建筑给排水毕业设计计算书

内容提要本工程位于广州市某花园内,由62~63号楼共两栋住宅组成的建筑物,总建筑面积约37799m2。

地面以上32层,地下一层,屋面标高98.000m。

其中首层为架空层,二~三十二层为住宅,地下一层为平时汽车库、战时人房及设备用房。

本设计主要是根据建设单位对本工程的技术要求,有关单位对本工程初步设计的批复以及建设单位所提供的有关市政,对广州市某花园内62~63号楼的给水设计、排水设计、消火栓设计、地下室自动喷淋系统设计和手提式灭火器设计。

本建筑62~63号楼最高日用水量为358.05m3/d,其水泵房设在本小区某号楼-1层,其中生活变频调速恒压给水设备除供本工程用水外,还供62~63号楼生活用水; 消火栓泵、喷淋泵设于本小区某号楼地下室。

小区供水方式采用分区供水的供水方式,地下负一层~三层由市政管网直接供水;四层及以上的住宅部分由小区某号楼地下一层水泵房的生活变频调速恒压给水设备分压供水,采用下行上给供水方式。

其中, -1~3层由小区市政给水管网直接供给:4~12层为低区供水,由设于地下一层的低区生活变频泵组直接供水;13~22层为中区供水,由设于地下一层的中区生活变频泵组直接供水; 23~32层为高区供水,由设于地下一层的高区生活变频泵组直接供水。

小区消防给水系统设计部分,室外为低压消防系统,由生活消防合用管道,室外消防用水量为 15L/S。

室内消火栓系统由泵房消火栓管网分别引入两条DN150管与上、下区连成环状供水。

消火栓消防用水量为 20L/S,火灾延续时间2小时。

室内消火栓给水系统竖向分为两个分区:低区为地下一层~十五层,高区为十六层~三十二层。

本设计还在天面设置屋顶试验用消火栓(不带消防卷盘),主要用于消火栓系统的实验和检修。

地下室设置自动喷水灭火系统,自动喷水灭火系统用水量为41.29L/S,火灾延续时间1小时。

地下室除不宜用水扑救的部分外均设自动灭火系统喷头,喷头直径为DN15,动作温度为68°C。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

高层建筑给排水毕业设计
高层建筑给排水毕业设计
近年来,随着城市化进程的加速和人口的不断增长,高层建筑的数量也不断增加。

而高层建筑的给排水系统设计是保证居民生活便利和环境卫生的重要一环。

在这篇文章中,我们将探讨高层建筑给排水毕业设计的一些重要考虑因素和技术。

首先,高层建筑给排水系统设计需要考虑到居民的用水需求。

随着人们生活水
平的提高,高层建筑的居民对于用水的需求也越来越大。

因此,在设计给水系
统时,需要考虑到居民的日常用水量和用水习惯,以确保供水充足且稳定。

同时,给水系统还应该能够满足高层建筑消防用水的需求,以保障居民的安全。

其次,高层建筑的排水系统设计需要考虑到排水的效率和环保性。

由于高层建
筑的排水管道较长且涉及到多个楼层,因此需要采用合理的管道布局和设计。

合理的管道布局可以减少水流的阻力,提高排水效率。

此外,还需要考虑到排
水管道的清洁和维护,以防止堵塞和漏水等问题的发生。

在环保方面,高层建
筑的排水系统设计应该考虑到废水的处理和回收利用,以减少对环境的影响。

另外,高层建筑的给排水系统设计还需要考虑到建筑的结构和安全。

高层建筑
的排水管道需要穿越多个楼层,因此需要考虑到管道对建筑结构的影响。

设计
师需要合理选择管道材料和管道支撑结构,以确保排水系统的稳定性和安全性。

同时,还需要考虑到排水系统与其他系统(如电力、通风等)的协调和配合,
以确保整个建筑的正常运行。

最后,高层建筑的给排水系统设计还需要考虑到未来的可持续发展。

随着科技
的不断进步和环境意识的增强,高层建筑的给排水系统设计也需要适应未来的
发展需求。

设计师需要考虑到新技术的应用和新材料的使用,以提高系统的效率和可持续性。

同时,还需要考虑到未来城市规划的发展趋势,以确保给排水系统能够适应未来城市的需求。

综上所述,高层建筑的给排水系统设计是一个复杂而重要的课题。

设计师需要考虑到居民的用水需求、排水的效率和环保性、建筑的结构和安全以及未来的可持续发展。

只有综合考虑这些因素,才能设计出高效、安全、环保的给排水系统,为居民提供便利的生活环境。

希望本文能够为高层建筑给排水毕业设计提供一些思路和参考。

相关文档
最新文档