片剂溶出度分析之令狐文艳创作

合集下载

吉他霉素片溶出度检查的再研究

吉他霉素片溶出度检查的再研究

吉他霉素片溶出度检查的再研究刘金凤1 康红钰2杨月华1 李岩1(1.河南省漯河市食品药品检验所,河南漯河462000;2.河南省漯河市医学高等专科学校,河南漯河462000)摘要:目的改变吉他霉素片溶出度试验条件,使溶出度检查和人的生理特点更接近,更能区分不同厂家药品的质量高低。

方法采用原法定方法和降低转速及改变溶出介质方法的比较。

结果质量好的药片二种方法的溶出度没有差别,而质量差的药片的溶出度二种方法有明显的差别。

结论建议吉他霉素片溶出度检查条件改成第二法,以盐酸溶液(5.6→1000)900ml为溶出介质,转速为每分钟50转;溶出介质配制简单,使用试剂少,对环境的污染也少。

关键词:吉他霉素片溶出度转速溶出介质Once More Study on the Examination at Dissolution ofKitasamycin TabletsLIU Jin-feng1,KANG Hong-yu2,YANG Yue-hua1,LI Yan1(1. Henan Luohe Institute for Food and Drug Control, 2. Henan Luohe Medical College, Luohe 462000,China)Abstract:Objective:To change experimental condition of dissolution of kitasamycin tablets, make the human physiological characteristics more close,and distinguish different manufacturers the quality of the drugs. Method:Adopting schedule method to compare with reducing revolutions and changing dissolution medium. Result:There is no difference of the two methods in the dissolution of drugs of good qulity,but there is significant difference in the dissolution of drugs of bad qulity.Conclusion: The second method was proposed to determine the dissolution of kitasamycin tablets,taking the hydrochloric acid solution (5.6-1000)900ml as dissolution medium,rotating speed is 50rpm; dissolution medium is simple and fewer reagent consumption with lower pollution.keywords:Kitasamycin tablets;Dissolution;Rotationai speed;Dissolution medium中图分类号:文献标识码:文章编号:吉他霉素片为临床常用药物,质量的好坏直接关系着人民群众用药的安全性与有效性。

头孢呋辛酯片的制备及其溶出度研究

头孢呋辛酯片的制备及其溶出度研究

头孢呋辛酯片的制备及其溶出度研究武宏伟;相婷;李银【摘要】目的制备头孢呋辛酯片,并与市售头孢呋辛酯片进行体外溶出度比较.方法采用微晶纤维素、交联聚维酮、微粉硅胶压制成头孢呋辛酯片,分别以pH4.0醋酸盐缓冲液、pH6.8磷酸盐缓冲液、水、0.1 mol·L-1盐酸溶液作为溶出介质,用桨法实验,绘制不同溶出介质中的溶出曲线,并计算出相似因子(f2).结果在4种溶出介质中,自制头孢呋辛酯片和市售头孢呋辛酯片的溶出曲线相似因子(f2)分别为73,68,65和82.结论自制头孢呋辛酯片和市售片的溶出行为一致.%Objective To prepare Cefuroxime Axetil Tablets and to compare the dissolution curves of self-made and market available tablets. Methods Cefuroxime Axetil Tablets were prepared by using microcrystalline cellulose, crosslinking polyvingypyrrolidone and silicon dioxide. Intellectual diffusion meter was used to determine the dissolution curve of market available Cefuroxime Axetil Tablets and self-made tablets. pH4. 0 acetate buffer solution,pH6. 8 phosphate buffer solution, water and 0. 1 mol o L-1 HC1 were used as dissolution media. The similarity factors (/2) were calculated in different dissolution media. Results The factors (f2) were 73,68,65 and 82 in pH4. 0 acetate buffer solution,pH6. 8 phosphate buffer solution, water and 0. 1 mol o L-1 HC1, respectively. Conclusion The dissolution profiles of self-made Cefuroxime Axetil Tablets are same as that of market available ones.【期刊名称】《西北药学杂志》【年(卷),期】2012(027)005【总页数】3页(P466-468)【关键词】头孢呋辛酯片;溶出曲线;相似因子【作者】武宏伟;相婷;李银【作者单位】扬子江药业集团北京海燕药业有限公司,北京,102206;扬子江药业集团北京海燕药业有限公司,北京,102206;扬子江药业集团北京海燕药业有限公司,北京,102206【正文语种】中文【中图分类】R944头孢呋辛酯是第二代头孢类抗生素,是头孢呋辛的前体药物,口服后迅速被胃肠道黏膜细胞中的非特异性酯酶水解,释放出头孢呋辛而发挥药效。

克拉霉素片溶出度检测方法分析

克拉霉素片溶出度检测方法分析

克拉霉素片溶出度检测方法分析目的优化克拉霉素片溶出度检测方法。

方法采用ZORBAX SB-C18(4.6 mm×150 mm,5 μm)色谱柱,流动相:磷酸盐缓冲液∶乙腈(60∶40),流速:1.0 ml/min,检测波长:210 nm;柱温:45 ℃,进样量:50 μl。

在药典方法基础上去掉稀释步骤,以每批次6片样品分别经溶出仪溶出后直接经高效液相色谱仪测定后按外标法以限度计算溶出度。

结果本法与药典方法相比较,溶出度结果一致,均大于限度80%,符合限度要求。

结论本研究方法可以作为克拉霉素片溶出度的质量控制方法。

Abstract:Objective To optimize the dissolution test of Clarithromycin tablets.Methods ZORBAX SB-C18(4.6mmx150mm,5μm)chromatographic column was used,mobile phase:phosphate buffer solution:acetonitrile(60:40),flow rate:1.0 ml/min,detection wavelength:210nm,column temperature:45℃,injection volume:50μL.We removed dilution steps on the basis of the Pharmacopoeia method,dissolution of 6 tablets in each batch was determined by high performance liquid chromatography after dissolution by dissolution analyzer,and the dissolution was calculated by external standard method.Results Compared with the Pharmacopoeia method,the dissolution rate was consistent with the limit of 80%,meeting the limit requirement.Conclusion This method can be used as a quality control method for dissolution of clarithromycin tablets.Key words:Clarithromycin;High performance liquid chromatography;Dissolution;Standard optimization克拉霉素(clarithromycin)属十四元环半合成大环内酯类抗生素,是一种新型红霉素药物[1]。

生物药剂学与药物动力学习题及答案1-15章之令狐文艳创作

生物药剂学与药物动力学习题及答案1-15章之令狐文艳创作

第一章生物药剂学概述令狐文艳【习题】一、单项选择题1.以下关于生物药剂学的描述,正确的是A.剂型因素是指片剂、胶囊剂、丸剂和溶液剂等药物的不同剂型B.药物产品所产生的疗效主要与药物本身的化学结构有关C.药物效应包括药物的疗效、副作用和毒性D.改善难溶性药物的溶出速率主要是药剂学的研究内容2.以下关于生物药剂学的描述,错误的是A.生物药剂学与药理学和生物化学有密切关系,但研究重点不同B.药物动力学为生物药剂学提供了理论基础和研究手段C.由于生物体液中药物浓度通常为微量或痕量,需要选择灵敏度高,专属重现性好的分析手段和方法D.从药物生物利用度的高低就可判断药物制剂在体内是否有效二、多项选择题1.药物及剂型的体内过程是指A.吸收B.渗透C.分布 D.代谢 E.排泄2.药物转运是指A.吸收B.渗透C.分布 D.代谢E.排泄3.药物处置是指A.吸收 B.渗透 C.分布 D.代谢 E.排泄4.药物消除是指A.吸收 B.渗透 C.分布 D.代谢 E.排泄三、名词解释1.生物药剂学;2.剂型因素;3.生物因素;4.药物及剂型的体内过程四、问答题1.生物药剂学的研究工作主要涉及哪些内容?2.简述生物药剂学研究对于新药开发的作用。

【习题答案】一、单项选择题1.C 2.D二、多项选择题1.ACDE 2.ACE 3.CDE 4.DE三、名词解释1.生物药剂学:是研究药物及其剂型在体内的吸收、分布、代谢与排泄过程,阐明药物的剂型因素、机体的生物因素与药理效应三者之间相互关系的科学。

2.剂型因素主要包括:(1)药物的某些化学性质:如同一药物的不同盐、酯、络合物或衍生物,即药物的化学形式,药物的化学稳定性等。

(2)药物的某些物理性质:如粒子大小、晶型、晶癖、溶解度、溶出速率等。

(3)药物的剂型及用药方法。

(4)制剂处方中所用辅料的种类、性质和用量。

(5)处方中药物的配伍及相互作用。

(6)制剂的工艺过程、操作条件和贮存条件等。

不同厂家麦白霉素片在5种溶出介质中的溶出曲线比较研究

不同厂家麦白霉素片在5种溶出介质中的溶出曲线比较研究

不同厂家麦白霉素片在5种溶出介质中的溶出曲线比较研究刘映倩;沈丹丹;吴群;林昀;唐倩【摘要】目的比较6个厂家麦白霉素片在5种溶出介质的溶出曲线,为全面评价药品质量提供依据.方法参照《中国药典》2010年版二部麦白霉素片测定方法,采用桨法进行在5种溶出介质中溶出度试验,以标准品对照法,对不同介质中的溶出曲线进行分析和比较.结果各厂家产品溶出行为差别较大,产品质量存在差异.其中B 厂麦白霉素片在各种溶出介质中60min时的累积溶出率均小于80%.结论建议有关厂家应对影响制剂溶出的辅料及生产工艺进行改进,以提高产品质量.【期刊名称】《中国抗生素杂志》【年(卷),期】2014(039)001【总页数】3页(P82-84)【关键词】麦白霉素片;溶出介质;溶出曲线【作者】刘映倩;沈丹丹;吴群;林昀;唐倩【作者单位】重庆市食品药品检验所,重庆市药物过程与质量控制工程技术研究中心,重庆401121;重庆市食品药品检验所,重庆市药物过程与质量控制工程技术研究中心,重庆401121;重庆市食品药品检验所,重庆市药物过程与质量控制工程技术研究中心,重庆401121;重庆市食品药品检验所,重庆市药物过程与质量控制工程技术研究中心,重庆401121;重庆医药高等专科学校,重庆400030【正文语种】中文【中图分类】R978.1+5麦白霉素(Meleumycin)为大环内酯类抗生素,是一种以麦迪霉素A1和吉他霉素A6为主,同时含其它少量成分的多组分混合物。

目前我国共有6个厂家生产麦白霉素片,规格为50mg和0.1g,其处方工艺差别较大。

国内外多采用在不同pH 溶出介质中测定体外溶出曲线来评价制剂的内在质量差异[1-3]。

本试验参照《中国药典》2010年版二部麦白霉素片的溶出度检查方法[4],采用浆法,以标准品对照,对6个生产企业各选1批次样品进行不同溶出介质中溶出曲线的考察,为评价国内麦白霉素片的质量情况提供依据,从而为药品的安全性、有效性和稳定性提供保障。

厄贝沙坦氨氯地平片溶出度评价

厄贝沙坦氨氯地平片溶出度评价

厄贝沙坦氨氯地平片溶出度评价李国琼;肖文礼;杨贵方;王俊;刘启兵【摘要】Objective To investigate the similarity of dissolution behavior between the reference preparation tablets ( the listed a‐broad Irbesartan and Amlodipine Tablets ,and the self‐prepared(domestic) preparations in dissolution media with different pH . Methods The HPLC method was adopted to determine the dissolubility according to Chinese Pharmacopoeia (edition 2010) and referring to the dissolution test condition in Japan′s Medical Drugs Quality InformationsSet .Water ,hydrochloride acid(pH=2) , acetate buffer(pH=4 .5) and phosphate buffer (pH=6 .8) were sepatately used as the dissolution media and the paddle method was adopted with the rotational speed of 50r · min-1 .The similarity of dissolution curve was evaluated by f2 similarity factor method .Results The similarity factor of self‐made tablets in different dissolution media to the imported tablets was above 50% . Conclusion The dissolution curve of self‐made and imported Irbesartan and Amlodipine Tablets is similar ,which prompts that this test preparation has the rational prescription and the production technology is stable and reliable .%目的:以国外原研的厄贝沙坦氨氯地平片为参比制剂,考察自研制剂与参比制剂在不同pH条件下溶出行为的相似性。

阿奇霉素不同剂型的溶出度方法学研究

阿奇霉素不同剂型的溶出度方法学研究
试验操作
在规定时间点取样,用紫外可见分光光度计测定溶液中阿奇霉素的浓度。同时,取空白溶剂作为对照,排除干扰。
01
02
03
阿奇霉素不同剂型的溶出度曲线拟合
04
数学模型的建立
选择合适的数学模型,如一元线性回归、多元线性回归等,对溶出度数据进行拟合,以客观反映阿奇霉素不同剂型的溶出度规律。
溶出度曲线拟合的方法学研究
不同剂型的溶出度数据比较
缓释片剂
02
阿奇霉素缓释片剂在溶出实验中,不同厂家生产的片剂溶出度有差异,但整体上均比普通片剂的溶出度高。其中某厂家的缓释片剂在30分钟内溶出度达到90%以上。
注射剂
03
阿奇霉素注射剂在溶出实验中,不同厂家生产的注射剂溶出度均比普通片剂和缓释片剂低,其中某厂家的注射剂在15分钟内溶出度仅达到60%左右。
通过对注射剂的溶出度曲线拟合结果的分析,探讨影响注射剂溶出度的因素,如药物成分、溶剂性质、制备工艺等。同时还需要考虑注射剂中可能存在的杂质和污染物对其溶出度的影响。
阿奇霉素不同剂型的溶出度数据比较与分析
05
普通片剂
01
阿奇霉素普通片剂在溶出实验中,不同厂家生产的片剂溶出度存在一定差异,其中某厂家的片剂在15分钟内溶出度达到85%以上,而其他厂家的片剂溶出度均未达到80%。
阿奇霉素不同剂型的溶出度方法学研究对于指导药品研发和生产具有重要意义,为新药研发提供理论支持和技术指导。
阿奇霉素不同剂型的溶出度方法学的应用价值
新技术应用
随着纳米技术、生物技术等新技术的不断发展,阿奇霉素不同剂型的溶出度方法学研究将有望借助新技术手段,提高研究的精准度和效率。
阿奇霉素不同剂型的溶出度方法学的展望与研究方向
普通片剂

维生素B6片溶出度方法学研究

维生素B6片溶出度方法学研究

维生素B6片溶出度方法学研究维生素B6是一种重要的水溶性维生素,也被称为吡哆醇。

它在人体中起着许多关键的生理功能,包括能量代谢、神经递质合成以及生理功能维持等。

研究维生素B6片剂的溶出度对于评估其质量和药效非常重要。

维生素B6片溶出度是指维生素B6从片剂中释放出来的速度和程度。

溶出度的研究可以从不同方面来进行,以确定影响维生素B6溶出的因素,如药物与载体的相互作用、片剂的成分和制备工艺等。

以下是一种可行的维生素B6片溶出度方法学研究。

1. 实验材料准备准备维生素B6片剂样品及其容器,确保所有试验材料干燥、无异物和纯度合格。

2. 溶出介质的选择选择适当的溶出介质,通常是生理缓冲液,pH值和温度需符合相关规定。

3. 溶出仪器设备准备准备好溶出仪器,如美国药典联合会(USP)溶出度测试仪,测试温度和转速需要符合规定。

4. 溶出实验方法(1)取一个维生素B6片剂,精确称量记录原料药的含量。

(2)将片剂放入溶出器的篮筒中。

(3)将篮筒装入溶出器中,将溶出器放入温度控制槽中。

(4)加入适量的溶出介质,启动溶出仪器,并设置所需的溶出参数,如温度、转速和采样时间等。

(5)根据不同的实验设计,设置适当的采样时间,每次采样时尽可能避免剂量袋接触到边缘或篮筒。

5. 采样和分析(1)定期取小样品进行溶出液采样。

(2)每次采样时,用适当的方法对溶出液样品进行分析和测量,例如高效液相色谱法(HPLC)。

(3)根据实验需要,可以选择合适的检测参数进行分析。

6. 数据处理和结果分析(1)计算出维生素B6片剂的溶出度百分比,可使用以下公式:溶出度百分比 = (采样溶出物中维生素B6的浓度 / 制剂中维生素B6的总含量)× 100(2)根据实验结果,进行数据处理和结果分析,如平均值、标准差、可溶出度曲线等。

在维生素B6片剂的溶出度方法学研究中,需要注意控制实验条件的一致性和重复性,确保实验结果的准确性和可重复性。

需要结合片剂的特性和药理学要求,综合考虑其他因素,以完善维生素B6片剂的溶出度研究。

过程分析阿莫西林分散片的溶出度

过程分析阿莫西林分散片的溶出度

过程分析阿莫西林分散片的溶出度杨淑梅;陈艳芬;李新霞;陈坚【摘要】目的建立阿莫西林分散片溶出度的光纤传感实时检测方法.方法参照新药转正标准中阿莫西林分散片的溶出度测定方法,采用桨法,转速75 r/min,以水为溶出介质,用光纤化学传感药物溶出度实时分析系统在272 nm处检测紫外吸收,同时用紫外分光光度法检测溶出浓度,以相互对照.结果在44.44~333.33 μg/ml范围内,吸收度与阿莫西林分散片的浓度成线形关系,日内、日间精密度及回收率的RSD均小于5%,2种测定方法差异无统计学意义(P>0.05).结论光纤传感药物溶出度实时分析系统在位、在线并且连续定量地反映了分散片体外速释的特性,更有效、准确地反映分散片释放的过程,过程监控准确,结果可信.【期刊名称】《新疆医科大学学报》【年(卷),期】2010(033)006【总页数】3页(P631-633)【关键词】光纤传感;阿莫西林分散片;溶出度测定方法【作者】杨淑梅;陈艳芬;李新霞;陈坚【作者单位】新疆医科大学药学院,新疆,乌鲁木齐,830000;新疆维吾尔自治区第二济困医院,新疆,乌鲁木齐,830000;新疆医科大学药学院,新疆,乌鲁木齐,830000;新疆医科大学药学院,新疆,乌鲁木齐,830000【正文语种】中文【中图分类】R28%R944.4口服速释固体制剂泛指服用后能快速崩解或快速溶解的固体制剂,有分散片、泡腾片、滴丸、口腔用膜剂等。

分散片又称水分散片,系指在水中能迅速崩解并均匀分散的一种片剂。

分散片中的药物应是难溶性的,分散片兼有片剂和液体制剂的优点,克服了两者的不足,与普通制剂相比,分散片具有分散状态佳、崩解时间短、药物溶出迅速、吸收快、生物利用度高、不良反应少、服用方便、性质稳定、携带和储存方便且其制备工艺简单(同普通片剂)等特点。

阿莫西林为白色或类白色结晶性粉末,在水中微溶,在乙醇中几乎不溶,它适合制备成分散剂型,但由于分散剂为速释制剂,现今溶出度检测手动取样方式无法监测其释放速度。

吉他霉素片溶出度检查的再研究

吉他霉素片溶出度检查的再研究

吉他霉素片溶出度检查的再研究刘金凤1 康红钰2 杨月华1 李岩1(1.河南省漯河市食品药品检验所,河南漯河462000;2.河南省漯河市医学高等专科学校,河南漯河 462000)摘要:目的改变吉他霉素片溶出度试验条件,使溶出度检查和人的生理特点更接近,更能区分不同厂家药品的质量高低。

方法采用原法定方法和降低转速及改变溶出介质方法的比较。

结果质量好的药片二种方法的溶出度没有差别,而质量差的药片的溶出度二种方法有明显的差别。

结论建议吉他霉素片溶出度检查条件改成第二法,以盐酸溶液(5.6→1000)900ml为溶出介质,转速为每分钟50转;溶出介质配制简单,使用试剂少,对环境的污染也少。

关键词:吉他霉素片溶出度转速溶出介质Once More Study on the Examination at Dissolution ofKitasamycin TabletsLIU Jin-feng1 ,KANG Hong-yu2 ,YANG Yue-hua1,LI Yan1(1. Henan Luohe Institute for Food and Drug Control, 2. Henan Luohe Medical College, Luohe 462000,China)Abstract:Objective:To change experimental condition ofdissolution of kitasamycin tablets, make the human physiological characteristics more close,and distinguish different manufacturers the quality of the drugs. Method:Adopting schedule method to compare with reducing revolutions and changing dissolution medium. Result:There is no difference of the two methods in the dissolution of drugs of good qulity,but there is significant difference in the dissolution of drugsof bad qulity. Conclusion: The second method was proposed to determine the dissolution of kitasamycin tablets,taking the hydrochloric acid solution (5.6-1000)900ml as dissolution medium,rotating speed is 50rpm; dissolution medium is simple and fewer reagent consumption with lower pollution.keywords:Kitasamycin tablets;Dissolution;Rotationai speed;Dissolution medium中图分类号:文献标识码:文章编号:吉他霉素片为临床常用药物,质量的好坏直接关系着人民群众用药的安全性与有效性。

左奥硝唑分散片的研制及溶出度测定方法的研究

左奥硝唑分散片的研制及溶出度测定方法的研究

左奥硝唑分散片的研制及溶出度测定方法的研究徐洁昵;谢安云;蒋银妹【摘要】Objective To prepare levornidazole dispersible tablets, and establish a dissolution determination method for levornidazole dispersible tablets in pharmacy research. Methods The prescription of levornidazole dispers ible tablets was optimized with indicator of disintegration. Dissolution of levornidazole dispersible tablet was determined by Ultraviolet spectrophotometry. Results The rational prescription was selected. The dissolution rate of levornidazole dispersible tablets in 3 min was more than 80% . The dissolution determination method was established, levornidazole concentration presented a good linear correlation within the range of 5. 329 ~26. 645 μg/mL with the average recovery of 99. 8% and a good precision( RSD =0.2% ). Conclusion The prescription was reasonable, levornidazole dispers ible tablets were characteristic of rapid dispersion, fast in dissolution. The method was suitable for the dissolution test of levornidazole dispersible tablets with simple operation and accurate consequence.%目的对左奥硝唑分散片进行处方分析,并建立溶出度测定方法.方法以崩解时限为指标,优选左奥硝唑分散片的处方;采用紫外分光光度法测定溶出度.结果确定了左奥硝唑分散片的处方,分散片于3 min时均已溶出90%以上.建立了溶出度测定方法,在5.329~26.645μg/mL浓度范围内,其吸收度值与浓度呈良好的线性关系(r=1.0),方法回收率为99.8%,精密度好(RSD=0.2%).结论筛选的处方合理,制得的左奥硝唑分散片分散快、溶出快.用紫外分光光度法测定左奥硝唑分散片溶出度,方法简单、可靠.【期刊名称】《实用药物与临床》【年(卷),期】2012(015)002【总页数】3页(P90-92)【关键词】左奥硝唑分散片;处方;溶出度【作者】徐洁昵;谢安云;蒋银妹【作者单位】沈阳药科大学药学院,沈阳110016;湖南医药工业研究所,长沙410014;长沙市华美医药科技有限公司,长沙,410007【正文语种】中文近年来,分散片作为口服速释制剂发展很快。

杨腊虎—药物溶出度检测技术

杨腊虎—药物溶出度检测技术

31
仪器(apparatus)适用(useful for)
VII.往复支架法 (ting holder)
透皮吸收膜剂
(transdemal patches),渗透 泵(osmotic)
优点(advantage) 缺点 (disadvantage)
小体积(small volume)
23
表1 生物药剂分类系统
Tab1 Biopharmaceutics classification system
分级(Class)
I II III IV
溶解性 渗透性 (solub (perme ility) ability) 高(high) 高(high) 高(high) 低(low) 低(low) 高(high) 低(low) 低(low)
标准仪器装置 膜片固定困难
(standard equipment can be used,only replace paddle by a stainless steel cylinder),
(patches are difficult to fix)
用于大的膜剂 (large patches can be tested)
11
2010年版中华人民共和国药典
▪ 药物溶出度释放度检测方法 ▪ 1,药物对照品法 ▪ 2,吸收系数法 ▪ 3,其他
12
2010年版中华人民共和国药典
▪ 考察溶出曲线: ▪ 一般制剂,取样时间45分钟 ▪ 限度(Q)一般为表示量的70% ▪ 复方制剂,视情而定。
13
近年来,全国每年有规模大小 不等的有关药物固体制剂质量分析 学术研讨会。
▪ 附录 XD 释放度测定法 ▪ 缓释制剂或控释制剂 ▪ 肠溶制剂 ▪ 贴剂

盐酸二甲双胍片溶出度的测定分析

盐酸二甲双胍片溶出度的测定分析

盐酸二甲双胍片溶出度的测定分析摘要:目的:分析盐酸二甲双胍片的溶出度,为临床合理用药提供依据。

方法:按照《中国药典》2005年版规定的溶出度测定法。

结果:3个厂家的产品均符合规定。

对照品、B厂产品各个时间点溶出度的标准差很小,反映出这2个厂家产品每片之间溶出度差异很小,质量均一、稳定,而A厂产品各个时间点溶出度的标准差较大,反映A厂产品各片之间溶出度差异较大,提示A厂产品质量均一性较差,需查找原因,改善其产品质量。

结论:吸收速度受溶出速度限制的药物,其生物利用度与溶出速度有较好的相关性。

提示药品生产部门应加强对药品溶出速度的监测,以便在生产中控制制剂的内在质量。

关键词:盐酸二甲双胍片;溶出度;测定盐酸二甲双胍是一种双胍类降血糖药,可降低肝糖元的异生,促进组织摄取葡萄糖[1],其作用主要是通过增强外周组织胰岛素介导的葡萄糖摄取和氧化代谢,且不刺激胰岛素的分泌,不引起低血糖,价格相对较低,目前在糖尿病的治疗中占有重要地位。

由于市售的盐酸二甲双胍片的种类较多,笔者选择了河南兴源制药有限公司的产品进行溶出度检查,并与其它厂家的产品进行比较,以期为临床用药提供参考。

1 仪器与试药1.1 仪器UV2100型分光光度计(日本岛津);ZRS-8型药物溶出仪(天津大学无线电厂);AG245电子天平(瑞士Mettler-Toledo公司);微孔滤膜及过虑装置(Millipore USA)。

1.2 试药盐酸二甲双胍对照品(中国药品生物制品检定所,批号:100666-200501),盐酸二甲双胍供试品(河南兴源制药有限公司,250mg/片);另外2个厂家的盐酸二甲双胍片(分别为A:国产,250mg/片;B:进口,250mg/片);超纯水(自制)。

1.3 方法1.3.1 储备液的制备精密称取盐酸二甲双胍对照品约25mg,置50mL量瓶中,加蒸馏水溶解,摇匀,即得0.5mg/mL的对照品储备液。

1.3.2 标准曲线的制备吸取盐酸二甲双胍对照品储备液0.05、0.10、0.25、0.50、0.75、1.00、1.25和1.50mL置50mL量瓶中,加水稀释至刻度,摇匀,配成0.5、1.0、2.5、5.0、7.5、10.0、12.5和15.0μg/mL的标准溶液。

关于阿莫西林胶囊溶出度问题的实验思考

关于阿莫西林胶囊溶出度问题的实验思考

关于阿莫西林胶囊溶出度问题的实验思考溶出度直接影响药物在体内的吸收利用,溶出度的检查也越来越被重视,因此其检测方法应进一步提高,利用高效液相色谱法代替紫外分光光度法,可以提高药品标准,保证药品质量。

标签:阿莫西林;溶出度;紫外分光光度法阿莫西林属于青霉索类抗生索,适用于敏感菌所致的感染,原理是通过抑制细菌的细胞壁合成而发挥杀菌作用。

药物的溶出度直接影响药物在体内的吸收和利用,是固体制剂质量标准的一个重要检查项目。

阿莫西林胶囊的溶出度检查,《中国药典》采用紫外分光光度法,但用紫外分光光度法测得的溶出度值,通过对本药检所两年来所抽样品检验结果的考察,分析、研究,发现小同厂家结果差别很大,有的超出含量很多、有的却低于规定的限度,但含量却相差小大,这些小合理现象,经多次试验研究发现,部分药品与生产工艺、添加的辅料有关,但也有部分药品与检测方法有关,通过改用高效液相色谱方法检测,改变溶出介质,结果合理、切合实际。

1 仪器和试剂1.1 仪器:SSIPC2300 高效液相色谱仪(美国SSI公司);岛津UV-2550紫外分光光度计(岛津);RCZ-8M型溶出试验仪(天津市天大天发科技);AUW120电子天平(岛津)。

1.2 试剂:河莫西林胶囊(批号4100144,4100076广州白云山制药有限公司;批号1001318,1004336,1003320,华北制药集团制剂有限公司;批号100126,四川蜀中制药有限公司);阿莫西林对照品(中国药品生物制品检定所,批号:130409-200609,含量86.6%);乙腈为一级色谱纯,其他所用试剂均为分析纯。

1.3 实验方法1.3.1 供试品溶液制备:采用中国药典附录中溶出度测定第一法——蓝法,以0.1mol/L盐酸溶液1000mL为溶剂,水浴温度。

(37±0.5)℃,转速为100r/min,每个吊篮放1粒胶囊,45min时,取溶液适量过滤,直接取滤液为供试品溶液。

三苯氧胺片剂的溶出度分析

三苯氧胺片剂的溶出度分析

三苯氧胺片剂的溶出度分析
李静;庞扶民;张汉宁
【期刊名称】《中国煤炭工业医学杂志》
【年(卷),期】1999(2)3
【总页数】1页(P281-281)
【关键词】三苯氧胺;片剂;溶出度
【作者】李静;庞扶民;张汉宁
【作者单位】煤炭工业部总医院制剂中心
【正文语种】中文
【中图分类】R944.4;R979.1
【相关文献】
1.国产氟苯水杨酸胶囊剂与进口片剂溶出度的比较 [J], 林芳;王胜浩
2.三种替硝唑片剂的溶出度分析 [J], 郑晓娴;金卫坤;夏运岳
3.苯恶丙嗪片剂溶出度试验 [J], 常广林;田德海
4.苯甲曲秦片剂含量及溶出度反相HPLC测定 [J], 刘辽;杨云霞;彭波;包定元因版权原因,仅展示原文概要,查看原文内容请购买。

不同厂家甲硝唑片溶出度的考察

不同厂家甲硝唑片溶出度的考察

不同厂家甲硝唑片溶出度的考察
王玉忠
【期刊名称】《天津药学》
【年(卷),期】2004(16)5
【摘要】目的:考察市售不同厂家甲硝唑片的溶出度.方法:采用转篮法对12个厂家的甲硝唑片进行体外溶出度测定,并进行溶出参数方差分析.结果:T50为5.51~20.04 min,Td为8.12~27.32 min.结论:12个厂家产品的体外溶出度均符合<中国药典>2000年版的规定,经统计学处理,不同厂家甲硝唑片抽验品的溶出参数有显著性差异(P<0.01).
【总页数】2页(P21-22)
【作者】王玉忠
【作者单位】天津静海药监分局药品检验所,天津,301600
【正文语种】中文
【中图分类】R927.11
【相关文献】
1.不同厂家甲硝唑片溶出曲线相似性考察 [J], 施春阳;杜佳敏;汪梦蝶;陈金利;叶志伟;方建国;王文清
2.不同厂家碳酸锂片的溶出度考察 [J], 张兴哲;赵丽元;邵纯君;贾瑞波
3.不同厂家甲硝唑片含量及溶出度考察 [J], 胡秋燕
4.不同厂家甲硝唑片含量及溶出度考察 [J], 胡秋燕
5.HPLC-UV法测定不同厂家甲硝唑片的含量和溶出度 [J], 江冬英;胡巧云
因版权原因,仅展示原文概要,查看原文内容请购买。

提高维生素B2片溶出度工艺改进之探讨

提高维生素B2片溶出度工艺改进之探讨

提高维生素B2片溶出度工艺改进之探讨
史向文;汪惟国;王茹
【期刊名称】《安徽医药》
【年(卷),期】2002(006)003
【摘要】@@ 中国药典"维生素B2片"质量标准项下明文规定该片剂的主药的溶出度应为≥75%[1].药典规定的片剂溶出度是该片剂中主药在规定的溶剂中溶出的速率与程度.在一定的时间内,主药溶出的多少,将直接影响到药物的疗效.
【总页数】2页(P69-70)
【作者】史向文;汪惟国;王茹
【作者单位】安徽省淮南市中联药业有限公司,淮南,232001;安徽省淮南市中联药业有限公司,淮南,232001;安徽省淮南市中联药业有限公司,淮南,232001
【正文语种】中文
【中图分类】R9
【相关文献】
1.荧光法测定医用维生素B2片剂中维生素B2的含量
2.维生素B2片的崩解和溶出度研究
3.紫外光纤化学传感原位过程监测维生素B2片溶出度
4.维生素B2片剂中维生素B2的荧光分光光度测定法
5.复合维生素B片中维生素B2溶出度测定方法研究
因版权原因,仅展示原文概要,查看原文内容请购买。

UV法测定坎地沙坦酯片溶出度 文随方

UV法测定坎地沙坦酯片溶出度 文随方

UV法测定坎地沙坦酯片溶出度文随方摘要:目的:建立坎地沙坦酯片的溶出度试验方法。

方法:采用UV法测定,检测波长为 257nm。

结果:坎地沙坦酯在 3.30~19.77μg/m L 浓度范围内线性关系良好(r=0.9999),坎地沙坦酯片的平均回收率为100.11%(RSD=0.78%)。

关键词:坎地沙坦酯;溶出度;UVDissolution of Candesartan Cilexetil Tablets by UVWensuifang,likunpingHainan General Sanyang Pharmaceutical Co.,Ltd,Haikou 570312ABSTRACTOBJECTIVE: To establish a method for determining of the dissolution of candesartan cilexetil tablets. METHODS:UV method was adopted. The detectionwavelength was set 257nm. RESULTS:The calibration curve was linear in the range of 3.30~19.77μg/m L,The average recoveries of candesartan cilexetil tablets were 100.11%(RSD= 0.78%).KEY WORDScandesartan cilexetil; dissolution;UV 坎地沙坦酯片是口服有效的高选择性血管紧张素Ⅱ型受体拮抗剂类抗高血压药,在胃肠道吸收时水解为坎地沙坦,发挥药效。

坎地沙坦酯对AT1受体的亲和力强,且耐受性好、半衰期长,是较好抗高血压药品。

[1],本文通过相关的溶出度方法学研究,采用UV法确定坎地沙坦酯片溶出度测定方法。

1 仪器与试药1.1 仪器Evolution 220紫外-可见分光光度计(Thermo);ZRS-8GD智能溶出试验仪(天大天发);FE20 pH计(梅特勒-托利多);XS105电子分析天平(梅特勒-托利多)。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

片剂溶出度的影响因素分析令狐文艳溶出度:是指药物从片剂等固体制剂在规定溶剂中溶出的速度和程度。

是片剂质量控制的一个重要指标。

固体口服制剂的生物利用度与药物的溶出度密切相关。

大多数口服固体制剂在给药后必须经吸收进入血液循环,达到一定血药浓度后方能奏效,从而药物从制剂内释放出并溶解于体液是被吸收的前提,这一过程在生物药剂学中称作溶出,而溶出的速度和程度称溶出度,从药品检验的角度上讲,溶出度系指药物从片剂或胶囊等固体制剂在规定的溶剂中溶出的速度和程度。

《中国药典》关于溶出度测定品种在逐年增多,从85 年版开始,为7个品种,90 年版为44 个(4个胶囊),95年版127个,至2000年版药典采用溶出度进行制剂质量控制的品种为183个,2015年则更多,上升幅度之快,也进一步说明了对片剂进行溶出度测定对稳定制剂内在质量,提高生物利用度的积极意义。

一般可以通过对辅料的选择,生产工艺的控制,测定条件等方面来分析讨论影响片剂溶出度的因素,提出合适的条件,切实提高片剂的溶出度,从而控制片剂的质量,以利提高片剂的生物利用度。

下文主要是针对一些网上查找及目前本公司现有的苯磺酸氨氯地平分散片生产时影响片剂溶出度的因素进行的可行性分析。

1 处方——辅料的选择辅料应为“惰性物质”,性质稳定,不与主药发生反应,不影响主药含量测定,对药物的溶出和吸收无不良影响。

实际上,辅料的理化性质是影响片剂质量的重要因素,对片剂的性质甚至药效可产生很大的影响,故应重视辅料的选择。

1.1苯磺酸氨氯地平分散片处方组成及处方量1 苯磺酸氨氯地平---主要原料成分x g2 微晶纤维素---填充剂(稀释剂)x g3 磷酸氢钙---填充剂(稀释剂)x g4 交联羧甲基纤维素钠---崩解剂x g5 微粉硅胶(二氧化硅)---润滑剂(助流剂、抗粘剂)x g6 羟丙甲基纤维素(HPMC)---润湿剂(粘合剂)适量共制成1000片1.1.1微晶纤维素---填充剂(稀释剂)微晶纤维素:具有高度可变性,对主药有较大的容纳性,同时有强烈的吸水膨胀作用,能使水分快速进入片剂内部、使片剂内部和外部都迅速崩解,是较为优良的稀释剂、干燥黏合剂和崩解剂。

国外产品的商品名为Avicel,并根据粒径的不同有若干规格。

国产微晶纤维素已在国内得到广泛应用,但其质量有待于进一步提高,产品种类也有待于丰富。

另外,片剂中含20%微晶纤维素时崩解较好。

成品硬度好,崩解性好。

1.1.2磷酸氢钙---填充剂(稀释剂)磷酸氢钙属无机盐类,其性质稳定,无嗅无味,微溶于水,与多种药物均可配伍,制成的片剂外观光洁,硬度、崩解良好,对药物无吸附作用。

1.1.3交联羧甲基纤维素钠---崩解剂交联羧甲基纤维素钠(Croscarmellose sodium,CCNa是交联化的纤维素羧甲基醚,大约有70%的羧基为钠盐型),由于交联键的存在,故不溶于水,但能吸收数倍于本身重量的水而膨胀,所以具有较好的崩解作用。

崩解剂的用量,理论上用量越多,膨胀性越好,但崩解时间不是最短,因为当崩解剂含量超过8%时,片剂内部毛细管变粗,水分的快速渗透反而隔离了周围细孔结构区,使其中的空气不能及时逸出,阻止水分进入细孔区。

1.1.4微粉硅胶(二氧化硅)---润滑剂(助流剂、抗粘剂)微粉硅胶(Aerosil) :即无定形SiO2 ,早期作为吸附剂,吸水、吸油性能好。

是带负电荷的触变胶,很轻,每1g其表面积为300~350m2 ,体积大。

对带正电荷的药物,在药物表面形成负电膜,流动性佳,是亲水性很强的难溶性物质,通过毛细管作用来辅助崩解。

微粉硅胶是优良的片剂助流剂,可用作粉末直接压片的助流剂。

其性状为轻质白色无水粉末,无臭无味,比表面积大,常用量为0.1%~0.3% 。

1.1.5羟丙甲基纤维素(HPMC)---润湿剂(粘合剂)羟丙基甲基纤维素(HPMC)在疏水性药物粒子的表面用亲水性辅料包上一层亲水性的“膜”,可降低药物的接触角,使药物易于润湿,故能有效地改变片剂的二次崩解,从而显著提高溶出度。

目前处方以申报与批准资料应一致,故无法对辅料品种及处方量进行调整与更换,况且上述辅料选型应该是可行的,但是对个别辅料的品种如微晶纤维素可进行进一步研究。

2 工艺的影响(为主要涉及工序,干燥、整粒、总混等暂未例入分析)2.1 粉碎、过筛原辅料进行微粉化处理,使其达到一定的粒度,混合后主药含量更为均匀,制得的片剂更为细腻均匀。

片剂中有效成分的溶出速率也大为加快,同等重量的药物,粒度越小,表面积越大,溶解越快,细粉比粗粉的绝对生物利用度能提高20% 。

如有可能可进行更小目数的粉碎及过筛。

2.2 制粒、整粒药物的颗粒度对于药物的质量有着直接的影响,颗粒度对药物的溶出性能起决定作用。

颗粒的粒度、均匀度、流动性影响了片剂的硬度、重量差异和含量均匀度。

颗粒的粒度愈小,压出片的硬度愈大,而均匀度、流动性好的颗粒,才能保证重量差异小,药物含量分布均匀,颗粒的第二次崩解好,从而改善药物的溶出性能。

湿法混合制粒则可将混合、制软材、分粒与滚圆制粒一次完成,制得的颗粒大小均匀、外观园整,流动性好,干燥后可得近似球形的细小颗粒,这种颗粒制得的片剂往往片面光洁细腻,药物溶出比较均匀,而采用摇摆式制粒机的工艺由于滚轴往复搓、拌软材,挤压出颗粒,尤其是两侧的长条,制成的颗粒硬度较大,崩解度、释放度、二次崩解均成问题。

颗粒的大小,硬度与粘合剂加入量,制软材时间长短有关,如有可能可进行减少粘合剂加入量或缩短时间。

另外有文献研究指出粘合剂温度对溶出度用明显影响,如果增加粘合剂温度至50℃可增加溶出度5%~10%,这是因为温度越低,粘合剂粘度愈大,与原辅料结合时不是均匀润湿物料,而是出现局部过湿现象,制得的颗粒不均匀,硬度增大,使溶出度减少。

观察制粒情况,制粒难易程度不同批次均不一样,两侧的长条状颗粒基本没有,但最后结束会出现大颗粒,如有可能最后部分物料可考虑适当增加筛网孔径,手工制粒。

有研究表明一般随着颗粒粒径加大,成品溶出度有所降低。

2.3压片制得的颗粒压片时应着重于压力、片重、硬度等的调节,压力的大小可改变骨架片的密度,使片剂的比表面积、孔隙率和孔道率发生变化,从而影响药物的释放。

一般情况下,压力越大,片剂比表面积、孔隙率及孔径减小,水分子进入片剂内部的速度变慢,崩解时间延长。

但比表面积并不总是随着压力的增大而减小。

一些药物片剂存在一个表面积最大时的压力(临界压力),在此压力之前加压,主要趋势是颗粒或结晶的破碎,所以压力越大,片剂比表面积越大,吸水速率快,一次崩解快,因而在压片时应着重于压力调整在适宜的度上,以寻求最快的崩解。

适当控制压片机压制时主压力,在保证片剂硬度前提下可作为考虑措施。

压力加大,产品溶出度有所降低。

3.实验条件的选择(以下参考网络文章)选择合适的溶出条件,可以客观地反映制剂的溶出情况,从而恰当地评价制剂质量。

由于测试样品在不同溶剂中溶解度有所不同,应对规定的溶出介质进行筛选。

药物在溶出介质中有一定的溶解度,同时对样品的测试无干扰现象,取样后,可补加等量同温溶出介质。

在对两制剂或两种以上制剂与对照药品的溶出度评价中,取样的时间选择很重要,在溶出度测定中随着溶出时间的增长,溶出差异逐渐减小,如取样的时间间隔较长,有时会出现难以区分溶出差异的情况,因此应选择适当的取样间隔,才能较全面的比较溶出情况。

不同转速情况下,溶出结果会有所不同,应选择合适的转速,在该转速条件下,溶出度结果无影响。

3.1仪器因素溶出度测定法是将某种固体制剂的一定量分别置于溶出仪的转篮 (或溶出杯 )中,在 (37.0±0.5) ℃恒温下,在规定的转速和溶出介质中依法操作,在规定时间内取样并测定其溶出量。

溶出度检查作为评价药品质量的一个重要指标,模拟口服固体制剂在胃肠道环境中的崩解和溶出,其重要性不言而喻。

溶出仪的调试在溶出度测定前,必须检查溶出仪的稳定性、转速和温度等是否符合要求。

①仪器运转时,整套装置应保持平稳,不能产生明显的晃动或振动 (包括仪器装置所处的环境 )。

②转轴应在中心孔并保持垂直状态,旋转应平稳无颤动,仪器应处于良好的稳定转动状态。

③检查仪器的实际转速与其仪器的电子显示数据是否一致,分别设置转速 50、 100和 150r /min 进行测定,用经校验的秒表计时,记下 2 min转动的次数,每 1 min转动次数误差均不得超过±4%。

④调试桨或篮的高度,在溶出杯未放入溶出介质时,按药典各法的要求,调节桨或篮的下端距溶出杯内底部的距离,应符合规定。

⑤设置好温度,用经校验的温度计测定溶出杯内溶出介质的温度,应能恒定在 (37.0±0.5) ℃, 6个溶出杯内的温度差异应小于±0.5 ℃。

⑥转篮的处理,应用转篮法试验时,应注意转篮的洁净程度,一般在阳光下观察转篮的空隙是否有堵塞。

如有堵塞,可采用超声处理或在稀硝酸中煮沸、再经水中煮沸的办法进行清理,否则将影响溶出度数据的准确性,尤其在低转速时,影响更为明显。

同时,还应注意试验时应取用干燥的转篮。

⑦水浴高度,溶出仪外围水浴高度应超过溶出杯里溶出介质液面高度,否则将影响溶出杯中溶出液的温度,导致结果偏低;尤其是进行缓、控释制剂试验时,由于试验时间较长,更需注意。

3.1.2溶出仪的校正溶出仪不仅各项机械性能指标(转速、轴距、高度等 )应符合溶出度检测的规定,同时,还应定期使用校正片对其性能进行校正。

特别是当试验中出现异常情况或检验结果有争议时,为保证实验结果的可靠性,必须用溶出度校正片对仪器进行校正。

溶出度校正片是由美国药典委员会在 20世纪70年代提出的。

因为溶出仪仅机械指标符合要求还不够,还应采用一定的标准制剂进行校正,对数据进行数理统计后必须符合一定的要求。

如不符合要求,应适当调整仪器的机械部件,直至校正片的测定符合规定。

我国目前使用的是非崩解型溶出度校正片为水杨酸片。

使用溶出度校正片不仅能确定溶出仪的性能状态,还能考查实验操作是否规范,因此校正片对溶出实验具有非常实用的价值,对确定溶出度结果偏差的来源有很大作用。

溶出仪在校正后,溶出杯需编号配对,溶出杯不配套对实验有一定的影响。

3.2 溶出介质的配制与脱气3.2.1溶出介质的脱气溶出度试验规定,溶出介质在试验前应进行脱气处理,因为介质中的气泡在实验过程中会影响样品的崩解、扩散和溶出。

溶出介质脱气处理对转篮法的影响较明显,因为溶液中的气泡会堵塞转篮空隙,影响样品溶出,而对桨法影响不大。

脱气方法一般采用煮沸法、抽滤法或超声法,煮沸法需煮沸15 min再放冷,如煮沸时间不足即放冷则除气效果不好。

较好的脱气方法是缓慢搅拌下加热至约 41 ℃,在真空条件下再不断搅拌 5 min,或减压抽滤,现在已有加热,抽真空,水循环搅拌一体化的仪器,脱气效果较好。

相关文档