气-汽对流传热数据处理
空气-蒸汽对流给热系数测定数据处理(数据表格、计算示例及图解)
一、原始数据记录表二、计算结果表实验号流量 温度(℃)m 3/h冷流体进口温度t1 冷流体出口温度t2 冷流体进口侧蒸汽温度T1冷流体出口侧蒸汽温度T2 1 5 35.8 76.8 102.9 102.4 2 7.5 36.6 76.5 101.9 101.2 3 10 37.2 76.9 102.2 101.8 4 12.5 38.4 77.5 102.5 102 5 15 40.1 77.8 102.4 101.9 6 17.5 41.9 78.3 102.5 101.9 7 20 43.4 78.6 102.4 101.8 8 22.544.1 78.5 102.5101.9序号Δt m \℃K W/m 2·℃Pr Re X Y m α21 43.2337 29.90223 0.597055 7324.592 1.143919 0.033442 0.020978 41.67203 2 41.99407 44.92077 0.596638 10982.84 0.826950.022261 0.020978 57.64489 3 41.92402 59.64674 0.595804 14633.02 0.656813 0.016765 0.020978 72.57683 4 41.33924 74.365130.5943118267.16 0.549236 0.013447 0.020978 86.79224 5 40.38487.940270.592657 21888.62 0.474507 0.011371 0.020978 100.4611 6 39.42766 101.6829 0.593118 25494.11 0.418598 0.009834 0.020978 113.8787 7 38.54594 114.7875 0.591641 29098.25 0.376053 0.008712 0.020978 126.7624 838.45563 126.43840.591149 32721.39 0.342197 0.007909 0.020978 139.3041计算示例:(以第一组为例)平均温度t 平均1=(t 1+t 2)/2=(35.8+76.8)/2=56.3℃ 此温度下,空气的各项物性分别为:空气进口处密度ρ’=1E-05*t 2-4.5E-03*t+1.2916=1.069947 空气的比热Cp :1005J/(kg ·℃) 温度在60℃以下 空气的导热系数λ=-2E-08*t 2+8*E-05*t+0.0244=0.028841空气的粘度μ=(-2E-06*t 2+5*E-03*t+1.7169)*1E-05=1.71338E-05序号平均温度t 平均空气进口处密度ρ’ 空气质量流量m 2 空气的比热Cp 实际流量V ’ 空气的导热系数λ空气的粘度μ NuNu/Pr 0.4ln(N u/Pr 0.4ln(R e)156.3 1.069947 0.001577 1005 0.001474 0.0288411.71338E-05 23.11853 28.41545 3.346933 8.898993 256.55 1.069104 0.002365 1005 0.002212 0.028861.71333E-05 31.95831 39.29159 3.671011 9.30409 357.05 1.067422 0.00315 1005 0.002951 0.0288991.71324E-05 40.18246 49.43051 3.900568 9.591036 457.95 1.064407 0.003932 1005 0.003694 0.0289691.71308E-05 47.93689 59.02894.078027 9.81286558.95 1.061076 0.004712 1005 0.00444 0.0290461.7129E-05 55.33806 68.21856 4.222717 9.993722 660.1 1.05727 0.005487 1009 0.00519 0.0291361.71268E-05 62.53688 77.06899 4.344701 10.1462 761 1.05431 0.006262 1009 0.005939 0.0292061.71251E-05 69.44557 85.66854 4.450486 10.27843 861.3 1.053327 0.007041 1009 0.006685 0.0292291.71245E-0576.25566 94.10077 4.544366 10.39578标定用流体的体积流量V 1=5m 3/h ρf=7800kg/m 3 ρ=1.205kg/m 3,由此可得出实际的空气流量为: V ’=()ρρρρρρ--f f ’)’(V=)()( 1.205-78001.069947 1.069947-7800205.136005=0.001474空气质量流量m 2=ρ’V ’=1.069947*0.001474=0.001577 d 2=0.016m l=1m 换热面积A=π*d 2*lm=0.020978d 4023.018.128.0=⨯⎪⎭⎫ ⎝⎛⨯π K=m 122p 2t t -t m ∆A c )(=43.2337*1*016.0*35.8-76.8*1005*0.001577π)(=29.90223Pr=λμ*p c =0.02884105-1.71338E *1005=0.597055Re===2d *V *4·d d πμρμρ’u 0.016*05-1.71338E * 1.069947*0.001474*4π=7324.592 X=8.022224.0Pr 1⎪⎪⎭⎫ ⎝⎛⨯μλm = 1.1439190.00157705-1.71338E 0.597055*0.02884118.00.4=⎪⎭⎫ ⎝⎛⨯ 0.0334421==KY 8.0224.0222m m Pr ⎪⎪⎭⎫ ⎝⎛⨯=μλα=41.6720305-1.71338E 0.0015770.0209780.597055*0.0288418.00.4=⎪⎭⎫ ⎝⎛⨯ 因为流体是被加热,故Nu 中n 取0.4,则:23.11853r *e *023.0u 4.08.0==P R N 28.415450.59705523.11853r 0.44.0==P Nu 3.3469330.59705523.11853ln Pr ln 0.44.0=⎪⎭⎫⎝⎛=⎪⎭⎫ ⎝⎛Nu 8.898993Re ln =)(三、冷流体给热系数的准数式:Nu/Pr 0.4=ARe m,由实验数据作图拟合曲线方程,确定式中常数A 及m,如下:500010000150002000025000300003500040000450005000020406080100ReData: Data1_B Model: Allometric1Equation: y = a*x^b Weighting: y No weightingChi^2/DoF = 2.8642E-11R^2= 1 a 0.023±1.9337E-8b 0.8±8.3367E-8N u /P r 0.4作曲线如上,按照y=a*x^b 拟合,由表内数据可知a=0.023,b=0.8;与Nu/Pr 0.4=ARe m 比较,即确定常数A=0.023,m=0.8 ,与经验式Nu/Pr 0.4=0.023Re 0.8中数值完全一致.四、以ln(Nu/Pr 0.4)为纵坐标,ln(Re )为横坐标,如下:8.89.09.29.49.69.810.010.210.410.63.23.43.63.84.04.24.44.6ln(Nu/Pr0.4 Linear Fit of C1l n (N u /P r 0.4ln(Re)Equation y = a + b*xAdj. R-Squ 1ValueStandard ErC1Intercep -3.772 5.88102E-6C1Slope0.8 5.99225E-7作曲线如上,按照y=a+b*x 拟合,由表内数据可知a=-3.772,b=0.8;即ln(Nu/Pr 0.4)=-3.772+0.8*ln(Re),取e 的指数,两边消去ln ,则8.0Re ln 772.30.4)ln(N u/PrRe 023.0*Nu/Pr 8.00.4===-e e e ,与Nu/Pr 0.4=ARe m比较,即确定常数A=e -3.772=0.023,m=0.8 ,与经验式Nu/Pr 0.4=0.023Re 0.8中数值完全一致.。
化工原理——传热实验NP
一、实验课程名称:化工原理二、实验项目名称:空气-蒸汽对流给热系数测定 三、实验目的和要求:1、 了解间壁式传热元件,掌握给热系数测定的实验方法。
2、 掌握热电阻测温的方法,观察水蒸气在水平管外壁上的冷凝现象。
3、 学会给热系数测定的实验数据处理方法,了解影响给热系数的因素和强化传热的途径。
四、实验内容和原理实验内容:测定不同空气流量下进出口端的相关温度,计算α,关联出相关系数。
实验原理:在工业生产过程中,大量情况下,冷、热流体系通过固体壁面(传热元件)进行热量交换,称为间壁式换热。
如图(4-1)所示,间壁式传热过程由热流体对固体壁面的对流传热,固体壁面的热传导和固体壁面对冷流体的对流传热所组成。
达到传热稳定时,有()()()()m m W M W p p t KA t t A T T A t t c m T T c m Q ∆=-=-=-=-=221112222111αα (4-1)热流体与固体壁面的对数平均温差可由式(4—2)计算,()()()22112211ln W W W W m W T T T T T T T T T T -----=- (4-2)式中:T W 1 -热流体进口处热流体侧的壁面温度,℃;T W 2 -热流体出口处热流体侧的壁面温度,℃。
固体壁面与冷流体的对数平均温差可由式(4—3)计算,()()()22112211ln t t t t t t t t t t W W W W m W -----=- (4-3)式中:t W 1 - 冷流体进口处冷流体侧的壁面温度,℃;t W 2 - 冷流体出口处冷流体侧的壁面温度,℃。
热、冷流体间的对数平均温差可由式(4—4)计算,()()12211221m t T t T ln t T t T t -----=∆ (4-4)δ TT W t Wt图4-1间壁式传热过程示意图当在套管式间壁换热器中,环隙通以水蒸气,内管管内通以冷空气或水进行对流传热系数测定实验时,则由式(4-1)得内管内壁面与冷空气或水的对流传热系数,()()MW p t t A t t c m --=212222α (4-5)实验中测定紫铜管的壁温t w1、t w2;冷空气或水的进出口温度t 1、t 2;实验用紫铜管的长度l 、内径d 2,l d A 22π=;和冷流体的质量流量,即可计算α2。
实验4传热(空气—蒸汽)
实验四:传热(空气—蒸汽)实验一、实验目的1.了解间壁式换热器的结构与操作原理;2.学习测定套管换热器总传热系数的方法;3.学习测定空气侧的对流传热系数;4.了解空气流速的变化对总传热系数的影响。
二、实验原理对流传热的核心问题是求算传热膜系数α,当流体无相变时对流传热准数关联式的一般形式为:(4-1)对于强制湍流而言,Gr准数可以忽略,故(4-2)本实验中,可用图解法和最小二乘法计算上述准数关联式中的指数m、n和系数A。
用图解法对多变量方程进行关联时,要对不同变量Re和Pr分别回归。
本实验可简化上式,即取n=0.4(流体被加热)。
这样,上式即变为单变量方程再两边取对数,即得到直线方程:(4-3)在双对数坐标中作图,找出直线斜率,即为方程的指数m。
在直线上任取一点的函数值代入方程中,则可得到系数A,即:(4-4)用图解法,根据实验点确定直线位置有一定的人为性。
而用最小二乘法回归,可以得到最佳关联结果。
应用微机,对多变量方程进行一次回归,就能同时得到A、m、n。
对于方程的关联,首先要有Nu、Re、Pr的数据组。
其准数定义式分别为:实验中改变冷却水的流量以改变Re准数的值。
根据定性温度(冷空气进、出口温度的算术平均值)计算对应的Pr准数值。
同时,由牛顿冷却定律,求出不同流速下的传热膜系数α值。
进而算得Nu准数值。
牛顿冷却定律:(4-5)式中:α—传热膜系数,[W/m2·℃];Q—传热量,[W];A—总传热面积,[m2];△tm—管壁温度与管内流体温度的对数平均温差,[℃]。
传热量Q可由下式求得:(4-6)W—质量流量,[kg/h];Cp—流体定压比热,[J/kg·℃];t1、t2—流体进、出口温度,[℃];ρ—定性温度下流体密度,[kg/m3];V—流体体积流量,[m3/s]。
三、实验设备四、实验步骤1.启动风机:点击电源开关的绿色按钮,启动风机,风机为换热器的管程提供空气2.打开空气流量调节阀:启动风机后,调节进空气流量调节阀至微开,这时换热器的管程中就有空气流动了。
对流给热系数的测定(数据处理)
实验三 对流给热系数的测定一、实验目的1、观察水蒸气在换热管外壁上的冷凝现象,并判断冷凝类型;2、测定空气(或水)在圆直管内强制对流给热系数i α;3、应用线性回归分析方法,确定关联式Nu=ARe m Pr 0.4中常数A 、m 的值。
4、掌握热电阻测温的方法。
二、基本原理在套管换热器中,环隙通以水蒸气,内管管内通以空气或水,水蒸气冷凝放热以加热空气或水,在传热过程达到稳定后,有如下关系式:V ρC P (t 2-t 1)=αi A i (t w -t)m (1-1)式中: V ——被加热流体体积流量,m3/s ; Ρ——被加热流体密度,kg/m3; C P ——被加热流体平均比热,J/(kg ·℃);αi ——流体对内管内壁的对流给热系数,W/(m2·℃); t 1、t 2——被加热流体进、出口温度,℃;A i ——内管的外壁、内壁的传热面积,m2;(T -T W )m ——水蒸气与外壁间的对数平均温度差,℃; 22112211ln )()()(w w w w m T T T T T T T T Tw T -----=- (1-2)(t w -t)m ——内壁与流体间的对数平均温度差,℃;22112211ln )()()(t t t t t t t t t t w w w w m w -----=- (1-3)式中:T 1、T 2——蒸汽进、出口温度,℃;T w1、T w2、t w1、t w2——外壁和内壁上进、出口温度,℃。
当内管材料导热性能很好,即λ值很大,且管壁厚度很薄时,可认为T w1=t w1,T w2=t w2,即为所测得的该点的壁温。
由式(1-3)可得:m w P i t t A t t C V )()(012--=ρα (1-4)若能测得被加热流体的V 、t 1、t 2,内管的换热面积A i ,以及水蒸气温度T ,壁温T w1、T w2,则可通过式(1-4)算得实测的流体在管内的(平均)对流给热系数αi 。
化工原理实验(四)空气-蒸汽对流给热系数测定
化工原理实验(四)空气-蒸汽对流给热系数测定一、实验目的1、 了解间壁式传热元件,掌握给热系数测定的实验方法。
2、 掌握热电阻测温的方法,观察水蒸气在水平管外壁上的冷凝现象。
3、 学会给热系数测定的实验数据处理方法,了解影响给热系数的因素和强化传热的途径。
二、基本原理在工业生产过程中,大量情况下,冷、热流体系通过固体壁面(传热元件)进行热量交换,称为间壁式换热。
如图(4-1)所示,间壁式传热过程由热流体对固体壁面的对流传热,固体壁面的热传导和固体壁面对冷流体的对流传热所组成。
达到传热稳定时,有()()()()mm W M W p p t KA t t A T T A t t c m T T c m Q ∆=-=-=-=-=221112222111αα (4-1)Tt图4-1间壁式传热过程示意图式中:Q - 传热量,J / s ;m 1 - 热流体的质量流率,kg / s ; c p 1 - 热流体的比热,J / (kg ∙℃); T 1 - 热流体的进口温度,℃; T 2 - 热流体的出口温度,℃; m 2 - 冷流体的质量流率,kg / s ; c p 2 - 冷流体的比热,J / (kg ∙℃); t 1 - 冷流体的进口温度,℃; t 2 - 冷流体的出口温度,℃;α1 - 热流体与固体壁面的对流传热系数,W / (m 2 ∙℃);A 1 - 热流体侧的对流传热面积,m 2;()m W T T -- 热流体与固体壁面的对数平均温差,℃;α2 - 冷流体与固体壁面的对流传热系数,W / (m 2 ∙℃);A 2 - 冷流体侧的对流传热面积,m 2;()m W t t - - 固体壁面与冷流体的对数平均温差,℃;K - 以传热面积A 为基准的总给热系数,W / (m 2 ∙℃); m t ∆- 冷热流体的对数平均温差,℃;热流体与固体壁面的对数平均温差可由式(4—2)计算,()()()22112211ln W W W W m W T T T T T T T T T T -----=- (4-2)式中:T W 1 - 热流体进口处热流体侧的壁面温度,℃;T W 2 - 热流体出口处热流体侧的壁面温度,℃。
实验报告-气-汽对流传热综合实验
实验报告-气-汽对流传热综合实验摘要:本实验旨在研究气汽对流传热特性,用实验数据确定理论模型参数,并分析能量守恒定律用于测定实验物体热量容量和总容量。
实验结果显示,气汽对流传热是由气流和质量流动引起的末端传热,在实验环境中表现为气汽对流传热。
由对实验数据的分析,可知通量和温度的关系,且表明了容量的大小与能量的守恒的相关性。
1、实验原理气汽对流传热是一种特殊的传热形式,发生在物体与气体或液体面之间,在其发生时,由于热量转移,而在这两表面之间发生气体或液体的运动,热流量是运动传递所引起的,从而造成介质两端的热量运动,从而形成传热。
2、实验步骤(1)实验仪器准备:实验仪器包括,气汽对流热传输实验台、调压罩、调压阀、进排气管、温度计、湿度计、压力表等设备。
(2)调试:把实验台上的调压阀打开,用手把调压罩拉落,手调温度计指针,在实验台上拉起温度拉丝,注意实验台传感器位置。
(3)启动实验:把实验装置测试面调节到预定温度,仔细测量压力、温度和湿度,即可进行实验。
3、实验结果(1)实验数据:通过实验台提供的实验数据发现,风口和吹出口的温度变化和压力变化存在一定的变化趋势,即在实验开始时,风口温度和吹出口温度都较高,压力较低;随着实验进行,它们相差越来越小,而压力也越来越增大。
(2)容量测定:借助观察实验数据,通过比较前后温度差以及定义的总容量、物体热量容量可以求得实验物体的热量容量和总容量的取值,说明实验物体的温度变化可以用叠加定律计算出来。
4、结论本实验证明,气汽对流传热是指在实验装置测试表面和空气之间形成的气体或液体流动传热。
实验结果表明,气汽对流传热对温度非常敏感,其传热。
实验6气-汽对流传热实验
实验6 气—汽对流传热实验6.1 实验目的(1) 了解套管换热器的构造及气—汽对流传热的机理。
(2) 掌握用热电偶温度计测量壁面温度的方法。
(3) 掌握传热膜系数α的测定方法,并学会传热膜系数测定实验的数据处理方法。
(4) 了解影响传热膜系数的因素和强化传热的途径。
6.2 实验原理传热膜系数α是研究传热过程及换热器性能的一个很重要的参数。
本实验所用换热器是由玻璃套管4和传热紫铜内管2构成的套管换热器。
冷流体为空气,由鼓风机11提供,并在换热器的内管中流动,其流量由旁路阀10调节,并由孔板流量计7和8(读数为R )测定,其进口和出口温度分别由温度计6和1测定。
热流体为饱和蒸汽,由电加热釜13和电加热器15等组成的蒸汽发生器提供,它在换热器的内管外流动。
由铜-康铜热电偶3、冷端温度补偿器(冰水浴保温桶)及毫伏表组成温度测量仪表,用于测量传热管的平均壁温。
由毫伏表测得热电动势E (mV ),即可得管外壁温度T (℃)值,由于紫铜管传热性能优异,可由管外壁温度代替内壁温度。
在套管换热器中,冷流体(空气)在管内作强制对流流动,热流体(水蒸汽)在管外流动。
冷、热两种流体呈逆流流动,通过间壁进行热交换。
流体在圆形管道内无相变时的准数关联式为 4.0Pr Re mA Nu =,将非线性转化为线性关系。
将实验得到的若干组Nu ,Re 和Pr 数据,由回归法确定系数m A ,值。
具体测定方法如下:对于准数关联式4.0Pr RemA Nu =(流体被加热时),将4.0Pr 移至左边,两边取对数,令()0.4lg Pr y Nu =,lg ;lg Re a A x ==,得y a mx =+,此式为一元线性式,按回归法即可得m 。
6.2.1 m 的计算:在双对数坐标系中以Re 为横坐标,以4.0Pr Nu 为纵坐标。
将测得的6组数据处理后得到6对横、纵坐标,在双对数坐标系中描出6个点,将6个点相连得一直线。
该直线的斜率即为准数关联式中的m 。
实验7. 空气-蒸汽对流给热系数的测定
实验7. 空气-蒸汽对流给热系数的测定一、实验目的1.熟悉传热过程及间壁式换热器的结构,掌握热电阻的测温方法;2.观察蒸汽在水平冷凝管外壁上的冷凝现象,测定对流给热系数h ;3.测定努塞尔数Nu 与雷诺数e R 之间的关系,并确定它们的关联式;4.了解强化传热的途径,分析热交换过程的影响因素。
二、基本原理工业生产中冷流体和热流体常通过固体壁面进行热量交换,此种换热方式称为间壁式传热。
间壁式传热过程是由热流体对固体壁面的对流传热、固体壁面的热传导和固体壁面对冷流体的对流传热过程组成,间壁式传热过程如图2—10所示。
当传热过程达到稳定时,它们有如下关系: 图2—10 间壁式传热过程示意图()()()()112122121122m p m p W W m M mq c t t q c T T h A t t h A T T KA t Φ=-=-=-=-=∆ (2—45) 式中:Φ—传热速率,W ;q m1、q m2 —冷、热流体的质量流量,1kg s -⋅; c p1、c p2 —冷、热流体的比热容,11kJ kg K --⋅⋅;T 1 、T 2—热流体的进出口温度,K ; t 1、t 2 —冷流体的进出口的度,K ;A 1、A 2—冷、热流体侧的对流传热面积,m 2;12,h h —冷、热流体与固体壁面的对流给热系数,21W m K --⋅⋅; ()W m t t -、()W m T T -—冷、热流体与固体壁面的对数平均温度差,K ;K —总传热系数,21W m K --⋅⋅; A —传热面积,m 2;m t ∆—对数平均温度差,K ;热流体与固体壁面的对数平均温差可由下式计算()()()22112211ln W W W W m W T T T T T T T T T T -----=- (2-46)式中:12,W W T T —热流体进出口处热流体侧壁面的温度,K 。
固体壁面与冷流体的对数平均温差可由下式求得()()()22112211ln t t t t t t t t t t W W W W m W -----=- (2-47)式中:12,W W t t —冷流体进出口处冷流体侧壁面的温度,K ; 冷热流体间的对数平均温度差可由下式计算()()12211221ln m T t T t t T t T t ---∆=-- (2—48)在套管式换热器中,由于水蒸气通过套管的环隙,冷空气或水通过内管间,测定对流给热系数时,由式(2—45)可得内管内壁面与冷空气或水的对流给热系数()()112111p W mm c t t h A t t -=- (2—49)实验中,要测定内管的壁温t w1和t w2,冷空气或水的进出口温度t 1和t 2;实验用套管的长度l ,内径d 1,换热面积11A d l π=,冷流体的质量流量及比热容,即可求得对流给热系数h 1。
传热学实验三-对流传热实验2
传热学实验三-对流传热实验2实验三对流传热实验一、实验目的⒈通过对空气—水蒸气光滑套管换热器的实验研究,掌握对流传热系数α1的测定方法,加深对其概念和影响因素的理解。
并应用线性回归分析方法,确定关联式Nu=ARemPr0.4中常数A、m的值。
⒉通过对管程内部插有螺纹管的空气—水蒸气强化套管换热器的实验研究,测定其准数关联式Nu=BRem中常数B、m的值和强化比Nu/Nu0,了解强化传热的基本理论和基本方式。
二、实验装置本实验设备由两组黄铜管(其中一组为光滑管,另一组为波纹管)组成平行的两组套管换热器,内管为紫铜材质,外管为不锈钢管,两端用不锈钢法兰固定。
空气由旋涡气泵吹出,由旁路调节阀调节,经孔板流量计,由支路控制阀选择不同的支路进入换热器。
管程蒸汽由加热釜发生后自然上升,经支路控制阀选择逆流进入换热器壳程,其冷凝放出热量通过黄铜管壁被传递到管内流动的空气,达到逆流换热的效果。
饱和蒸汽由配套的电加热蒸汽发生器产生。
该实验流程图如图1所示,其主要参数见表1。
表1实验装置结构参数实验内管内径di(mm)16.00实验内管外径do(mm)17.92实验外管内径Di(mm)50实验外管外径Do(mm)52.5总管长(紫铜内管)L(m)1.30测量段长度l(m)1.10蒸汽温度空气出口温度空气入口温度蒸汽压力空气压力孔板流量计测量空气流量图1空气-水蒸气传热综合实验装置流程图1—光滑套管换热器;2—螺纹管的强化套管换热器;3—蒸汽发生器;4—旋涡气泵;5—旁路调节阀;6—孔板流量计;7、8、9—空气支路控制阀;10、11—蒸汽支路控制阀;12、13—蒸汽放空口;15—放水口;14—液位计;16—加水口;三、实验内容1、光滑管①测定6~8个不同流速下光滑管换热器的对流传热系数α1。
②对α1的实验数据进行线性回归,求关联式Nu=ARem中常数A、m的值。
2、波纹管①测定6~8个不同流速下波纹管换热器的对流传热系数α1。
气汽对流传热综合实验数据处理
1234孔板压差ΔP(KPa)0.52 1.53 2.56 3.57空气入口温度t1(℃)25.626.126.526.8ρt1(kg/m3) 1.18 1.18 1.18 1.18空气出口温度t2(℃)72.766.166.167.5壁面温度Tw(℃)99.799.799.799.7管内平均温度t m(℃)49.1546.146.347.15ρm(kg/m3) 1.09 1.1 1.1 1.1λm(W/m·℃)0.0280.0280.0280.028 Cp m(J/kg·℃)1005100510051005μm(Pa·s)0.00001970.00001950.00001950.0000195空气进出口温差Δt(℃)47.14039.640.7平均温差Δt m (℃)50.5553.653.452.55 20℃时空气流量V20(m3/h)16.3728.0736.3142.88计量计处空气流量Vt1(m3/h)16.5228.3636.7143.38管内平均流量Vm(m3/h)17.9030.9740.0147.10平均流速um(m/s)15.8327.3835.3741.64传热量Q(W)381.29705.86908.481052.47αi(W/m2·℃)120.03209.56270.73318.71 Re17514.4030892.1839908.6146981.93Nu85.74149.69193.38227.65Pr0.710.700.700.70Pr0.40.870.870.870.87Nu/Pr0.498.49172.65223.04262.58孔板压差ΔP(KPa)0.20.7 1.2 1.7空气入口温度t1(℃)30.631.332.132.4ρt1(kg/m3) 1.165 1.161 1.158 1.158空气出口温度t2(℃)81.676.776.576壁面温度Tw(℃)100100100100管内平均温度t m(℃)56.15454.354.2ρm(kg/m3) 1.073 1.08 1.08 1.08λm(W/m·℃)0.2870.2860.2860.286 Cp m(J/kg·℃)1005100510051005μm(Pa·s) 1.94*10^-6 1.93*10^-6 1.93*10^-6 1.93*10^-6空气进出口温差Δt(℃)5145.444.443.6平均温差Δt m (℃)43.94645.745.8 20℃时空气流量V20(m3/h)10.1518.9924.8629.59管内平均流量V(m3/h)1120.4126.6731.7d i=0.02m L=1.00m 冷流体:空气(管内)流体:蒸汽(管外)平均流速u(m/s)9.7218.0423.5828.03传热量Q(W)168279.4457416.7αi(W/m2·℃)60.996.66124.3144.8 Re10752201902639031370 Nu42.4467.5986.92101.26 Pr0.6790.6780.6780.678 Nu/Pr0.449.5578.96101.54118.29 Nu036.9160.0873.9284.51 Nu/Nu0 1.15 1.13 1.18 1.21234孔板压差 ΔP(KPa)0.260.76 1.26 1.76空气入口温度t 1(℃)28.528.929.329.7ρt1(kg/m 3) 1.165 1.165 1.165 1.165空气出口温度t 2(℃)86.57873.972.6壁面温度Tw(℃)99.799.799.799.7管内平均温度t m (℃)57.553.4551.651.15ρm (kg/m 3)1.06 1.09 1.09 1.09λm (W/m ·℃)0.0290.02830.02830.0283Cp m (J/kg ·℃)1005100510051005μm (Pa ·s)0.0000201 1.96E-050.00001960.0000196空气进出口温差Δt(℃)5849.144.642.9平均温差Δt m (℃)42.246.2548.148.5520℃时空气流量V 20(m 3/h)10.1524.8633.6640.6d i =0.02m L=1.00m 冷流体:空气(管内) 流体:蒸汽(管外)计量计处空气流量10.3025.2334.1941.27Vt1(m3/h)管内平均流量Vm10.7626.6836.3243.84(m3/h)平均流速um(m/s)9.5223.5932.1138.75传热量Q(W)134.42375.55531.54647.61αi(W/m2·℃)50.69129.22175.86212.27 Re10037.0526239.6735710.2843104.86Nu34.9691.32124.28150.01Pr0.700.700.700.70Pr0.40.870.870.870.87 Nu/Pr0.440.40105.56143.66173.41 Re0.81611843.794039.355194.396056.71 Nu027.6060.4577.7490.64 Nu/Nu0 1.15 1.13 1.18 1.20。
传热实验数据处理完整版
空气平均流速utm(m/s)
空气在平均温度时的物性
ρm(kg/m3)
μm*10^5(Pa·s)
λm*10^2(W/m·℃)
Cp(kJ/kg·℃)
空气进出口温度之差t2-t1(℃)
26
壁面和空气的温差tw-tm(℃)
空气得到的热量Q(kW)
空气侧对流传热系数αi(W/m2.℃)
Re
Nu
Pr
Nu/(Pr^
Nu0
Nu/Nu0
图三
图四
图五
空气平均流量Vtm(m3/h)
空气平均流速utm(m/s)
空气在平均温度时的物性
ρm(kg/m3)
μm*10^5(Pa·s)
λm*10^2(W/m·℃)
Cp(kJ/kg·℃)
空气进出口温度之差t2-t1(℃)
36
壁面和空气的温差tw-tm(℃)
空气得到的热量Q(kW)
空气侧对流传热系数αi(W/m2.℃)
Re
Nu
Pr
Nu/(Pr^
Nu/(Pr^
图一
图二
表二
强化套管换热器数据
传热管内径:18mm传热管有效长度:1m冷流体:空气 热流体:水蒸气
序号
1
2
3
4
5
6
空气流量读数P(kPa)
空气入口温度t1(℃)
空气出口温度t2(℃)
壁温tw(℃)
空气在t1时的密度ρt1(kg/m3)
空气平均温度tm(℃)
空气在入口处流量Vt1(m3/h)
传热实验数据处理
五、实验数据记录及处理
表一
简单套管换热器数据
传热管内径:18mm传热管有效长度:1m冷流体:空气热流体:水蒸气
冷空气——蒸汽的对流传热实验
∆������������
=
∆������1−∆������2 ������������∆∆������������12
=
(99.5−25.1)−(99.5−67.7) ������������9999..55−−2657..17
℃=50.12℃
传
热
速
率
Q
=
������������������������������(������2
5.稳定 10~15min,记录冷空气流量,蒸汽温度和冷空气进、出口温度。
6. 调节空气 支路调节阀( 逐渐关闭闸阀 16),改变冷空气流量,稳定 10~15min后,记录冷空气流量,进、出口温度和蒸汽温度。
7.重复操作实验步骤 6 八至十次,流量从大到小,均匀分布,完成 1#换热器 的测定。
8.全开冷空气支路调节阀(闸阀 16),选择另一个换热器 2#换热器,全开此 换热器切换阀(球阀 2),管壁已做完实验的 1#换热器的切换阀(球阀 3)。
内径:25mm
外径:30mm
定性温
度������������ (℃)
传热面 积A (m2)
平均 传热速 温差 率 Q ∆������������(℃) (W)
总传热 系数 K (W/( m2/s))
管长:1.3m
Nu
Re
1 19.8 46.4 0.123 50.1 260.44 45.63 40.4 15620.6
3 48.7 54.8 0.123 41.7 503.75 74.80 66.2 38420.3
4 45.0 53.5 0.123 43.8 489.10 74.32 65.8 35501.3
5 40.7 52.8 0.123 43.4 457.44 70.44 62.3 32109.0
实验三+蒸汽─空气对流传热传热系数的测定
实验三 蒸汽─空气对流传热传热系数的测定一、实验目的1. 测定套管式换热器的总传热系数K ;2. 测定圆形直管内传热膜系数α,并学会用实验方法将流体在管内对流及强制对流 时的实验数据整理成包括传热膜系数α的准数方程式;3. 了解并掌握热电偶和电位差计的使用及其温度测量。
二、基本原理1.测定传热系数K根据传热速率方程式:m T KA ∆=φ (1)mT A K ∆=φ(2)式中: φ传热速率,W ; K 总传热系数,W/(m 2·℃);A 传热面积; m T ∆两流体的平均温度差。
实验时,若能测定或确定φ、A 和,则可测定K 。
m T ∆⑴ 实验是测定蒸汽加热空气时的对流传热总传热系数,其中蒸汽通加套管环隙加热内管的空气,具体的流程如下:在不考虑热损失的条件下,有)(122211T T c q r q p −==m m φ (3)式中: q m1— 蒸汽冷凝液的质量,kg/s ; r 1 — 蒸汽冷凝潜热,J/kg ;q m2— 空气的质量流量,kg/s ; c p2 — 空气的定压比热,J/(kg ·K);T 1、T 2— 空气的进出口温度,℃; T W1、T W2— 内管外壁温度与内壁温度,℃。
实验中传热速率φ按空气的吸热速率计算。
其中空气的质量流量由孔板流量计测量其 体积流量后转化为质量流量。
即:q m =t ρq V (4)式中:t ρ—为空气进出口平均温度下的密度,kg/m 3。
q V — 为空气的体积流量,m 3/s 。
本实验中,空气的体积流量由孔板流量计测量并通过压力传感器将其差压数字在显示仪表上显示出。
20℃ 下空气流量由公式(5)计算。
6203.000)(p C q t ∆×=V (5)其中, — 20℃ 下的体积流量,m 0t q V 3/h ;C 0— 孔板流量系数,本实验装置中其值为22.696。
p ∆—孔板两端压差,kPa 。
则实验条件下的空气流量q V (m 3/h)则需按下式计算:2732730t Tq q t t ++×=V V式中:t q V —实验条件(管内平均温度)下的空气流量,m 3/h 。
传热综合实验
其中Qi=WiCpi(t2-t1),Wi= ;Δtm= ,Δt2=tw-ti2,Δt1=tw-ti1;Si=πdiLi
式中,Wi为冷凝速率,kg/s;Vi为体积流量,m3/s;ρi为密度,kg/m3;Cpi为定压比热容,kJ/(kg·°C);t1为入口温度,°C;t2为出口温度,°C;tw为管壁温度,°C;di为管直径,m;Li为管长,m。
实验条件:装置号 内管内径/壁厚/外径=20.0/1.0/22.0mm
入口温度ti1/°C
出口温度to1/°C
壁温tW/°C
孔板流量计ΔP/kPa
管路压降 ΔP1/kPa
1
2
3
4
5
6
备注:
表2-2 2号管换热器实验数据记录表
实验条件:装置号 内管内径/壁厚/外径=20.0/1.0/22.0mm
入口温度ti2/°C
0.06644
奴塞尔数Nu×10-3
0.08762
0.08226
0.07762
0.06859
0.05902
0.04666
雷诺数Re×10-4
5.0077
4.5964
4.1329
3.5589
2.8982
1.9361
普朗特数Pr×10
6.96813
6.96936
6.97044
6.97139
6.97184
3.必须保证空气管线的畅通。即在接通风机电源之前,三个空气支路控制阀之一和旁路调节阀必须全开。在转换支路时,应先关闭风机电源,然后开启、关闭控制阀。
4.调解流量后,应至少稳定5~8分钟后读取实验数据。
5.实验中保持上升蒸汽的稳定,不应改变加热电压,且保证蒸汽放空口一直有蒸汽放出。
化工原理实验复习题
空气-蒸汽对流给热系数测定一、问答题1. 传热实验中,套管换热器上方的排气阀有何作用?排放不凝性气体,提高传热效率。
2. 实验结束后,为什么要先关蒸汽,再关鼓风机?让风机输送的冷空气尽快将热量带走,使系统恢复常温。
3. 为什么在双对数坐标系中准数关联式近似为一条直线?只有在双对数坐标系中才能将非线性的准数关联式转化为线性关系。
4. 气—汽换热的结果是什么?冷空气变为热空气,水蒸汽变为冷凝水。
5.实验中使用的孔板流量计设计原理是什么?依据柏努利方程,动能与静压能之间的转换。
6. 在用饱和水蒸汽加热空气的传热实验中,测得管壁面温度接近蒸汽温度,原因是什么?蒸汽冷凝对流传热系数远大于空气对流传热系数,因此壁温接近蒸汽温度。
7. 在传热实验中,要提高数据的准确度,在实验操作中要注意哪些问题?(1)实验过程中应使蒸汽压力维持恒定。
(2)流量的调节应从大到小,而且每次调节流量后应稳定15分钟后才开始读取数据。
8. 传热实验时为何要维持加热蒸汽压恒定?加热蒸汽压恒定,保障蒸汽进口的温度恒定,热量衡算时减小误差。
二、实验操作学生能正确指出设备上的有关管件、阀门、流量计、热电阻等。
简述操作过程,模拟操作。
干燥特性曲线测定实验一、问答题1. 干燥实验进行到试样重量不再变化时,此时试样中所含的水分是什么水分?实验过程中除去的又是什么水分?二者与哪些因素有关。
答:当干燥实验进行到试样重量不再变化时,此时试样中所含的水分为该干燥条件下的平衡水分,实验过程中除去的是自由水分。
二者与干燥介质的温度,湿度及物料的种类有关。
2. 对流干燥的特点?答:当温度较高的气体与湿物料接触时,气固两相间发生的是热质同时传递的过程。
3.湿球温度是指什么温度?跟什么有关?答:大量空气与少量水长期接触后水面的温度。
是空气湿度和干球温度的函数。
4. 什么是恒定干燥条件?本实验装置中采用了哪些措施来保持干燥过程在恒定干燥条件下进行?答:干燥介质的温度、湿度、流速及与物料的接触方式,在整个干燥过程中均保持恒定。
实验四 气汽对流传热综合实验报告
化学实验教学中心实验报告化学测量与计算实验Ⅱ实验名称:气-汽对流传热综合实验报告学生姓名:学号:院(系):年级:级班指导教师:研究生助教:实验日期: 2017.05.26 交报告日期: 2017.06.02掌握对流传热系数应用线性回归分析方法,确定关联式中常数,对流传热系数在该实验中,空气走内管,蒸汽走外管。
对流传热系数式中,为管内流体对流传热系数,;为管内传热速率,;管内换热面积,为内壁面与流体间的温差,由右式确定:式中,分别为冷流体的入口、出口温度,为壁面平均温度,温度近似相等,用管内换热面积:式中,为内管管内径,;为传热管测量段的实际长度,由热量衡算式:其中质量流量由右式求得:式中,为冷流体在套管内的平均体积流量,;为冷流体的定压比热,;冷流体的密度,。
可根据定性温度查得,为冷流体进出口平均温度。
可采流体在管内做强制湍流,被加热状态,准数关联式的形式为:其中,,物性数据可根据定性温度查得。
经计算可知,对于管内被加热的空气,普兰特常数与,然后用线性回归方法确定的值。
科学家通过实验研究总结了形式为的形式是:是强化管的努塞尔准数,;为孔板两端压差,为空气入口温度(及流量计(2)温度的测量传热管内径孔板压差空气入口温度壁面温度管内平均温度空气进出口温差平均温差℃时空气流量平均流速传热量孔板流量计压差、空气入口温度已知数据及有关常数及流通截面积及传热面积管内换热面积:先算出空气的定性温度在此温度下空气的物性数据如下:;;;和平均流速℃,需进行校正,传热管内的体积流量平均流速(5)壁面和冷热流体间的平均温度差的计算:)传热速率)管内传热系数)传热准数:雷诺准数:普兰特常数:纵坐标,为横坐标,在对数坐标系上标绘由图得线性回归方程如下:传热管内径孔板压差空气入口温度壁面温度管内平均温度空气进出口温差平均温差℃时空气流量平均流速传热量步,并将数据结果填到表)求强化套管换热器关联式纵坐标,为横坐标,在对数坐标系上标绘关系,见图)强化比将强化套管换热器求得的数代入光滑套管换热器所得的准数关联式中,可以得到组数据:(三)绘图纵坐标,为横坐标,在对数坐标系上标绘种换热器本身来说,改变孔板温差,对流传热系数由此可知,影响对流传热系数②光滑管和强化管换热器的准数关联式中常数。
传热综合实验
气---汽对流传热综合实验班级:化学工程与工艺姓名:韩兴云学号:033112037 组别:甲4一、实验目的:1、测定光滑圆形直管管外蒸气冷凝,管内为空气强制对流时的传热系数——K值;2、学会用实验方法,讲所测实验数据整理成准数方程式3、了解并掌握热电偶和电位差计的使用,及其温度测量。
二、基本原理概述1、测定传热系数K。
根据传热速率方程式得:其中:传热速率Q,既可以用热流体得放热速率计算,也可以用冷流体的吸收速率计算。
传热推动力Δtm可用对数平均温度差计算。
逆流时,S=лdl2、测定给热系数α在蒸汽-空气换热系统,若忽略管壁与污垢的热阻,则总传热系数与分传热系数的关系为:由于蒸汽冷凝给热系数远大于管壁对空气的给热系数,所以α1=K3、求与Re的定量关系式。
由因次分析法可知,流体在圆形管中呈强制湍流时的给热系数,符合下列准数关联式:本实验就是通过调节空气的流量,测得对应的给热系数,然后将流量整理为Re,将给热系数整理为Nu。
再将所得的一系列Nu-Re数据,通过图解法或者回归分析法,求得待定系数A、n。
进而得到给热系数α与Re的经验公式。
三、装置与流程:来自鼓风机的空气通过调节阀1转子流量计2和换热管3,经换热后排空。
热量由缠绕在换热管表面的电热丝4供给;空气流量由转子流量计2测定;进、出口空气温度由温度计读取,其进口压强由U形管液柱压差计显示;壁温由热电偶测量。
四、实验数据及处理:表一普通套管换热器原始数据表二强化套管换热器原始数据表三普通套管换热器实验数据处理表t2 /℃67.1 66.4 65.7 65.7 66.5 67.8 68.2t /℃48.8 49.6 49.6 50.4 52 54.3 54.9ρ/(kg/m3) 1.097 1.094 1.094 1.092 1.086 1.079 1.077 Cp/(J/kg·k)1005λ/(w/m·k)0.02816 0.02821 0.02821 0.02827 0.02838 0.02854 0.02858 μ/(Pa·s)19.5 19.6 19.6 19.6 19.7 19.8 19.8Pr0.4 0.866Vt0/(m3/h) 15.57 23.62 29.64 34.49 38.42 42.11 42.99 V/(m3/h) 16.51 24.92 31.2 36.21 40.23 43.94 44.81 Tw/℃109.2 109.5 109.5 109.5 109.5 109.5 109.5 Δtm/℃60.4 59.9 59.9 59.1 57.5 55.2 54.6Q/w 185.6 255.7 306.8 338.9 354.9 358.7 358.4 α/(w/m2·℃)48.9 67.9 81.5 91.3 98.2 103.4 104.5 Nu 34.7 48.1 57.8 64.6 69.2 72.5 73.1u/(m/s) 14.6 22.03 27.58 32.01 35.57 38.85 39.62 Re 16426.9 24592.7 30788.3 35668.3 39217.3 42342.6 43101.8 lnNu 3.55 3.87 4.06 4.17 4.24 4.28 4.29 lnRe 9.71 10.11 10.33 10.48 10.58 10.65 10.67由Nu=ARemPr0.4 , 可得lnNu=lnA+mlnRe+0.4lnPr所以以lnNu——lnRe作图,可得一直线,直线的斜率是m,截距是lnA+0.4lnPr作图,可得m=0.78,lnA+0.4lnPr=-3.9922,所以A=0.0195即Nu=0.0195Re0.78Pr0.4表四强化套管换热器实验数据处理表Nu 103.7 98.7 91.1 81.5 70.5 51.7u/(m/s) 35.89 32.96 29.12 25.06 20.55 13.77 Re 37854.1 35102.4 31402.8 27262.2 22397.4 15007.9 lnNu 4.64 4.59 4.51 4.40 4.25 3.95 lnRe 10.54 10.47 10.35 10.21 10.02 9.62由Nu=BRem, 可得lnNu=lnB+mlnRe所以以lnNu——lnRe作图,可得一直线,直线的斜率是m,截距是lnB.作图得,m=0.75 , lnB=-3.30677所以B=0.0366即 Nu=0.0366Re0.75强化比的计算:同一流量下,强化管的努塞尔准数Nu与普通管的努塞尔准数Nuo之比,即Nu/Nuo.当流量等于40.60m3/h时,Nu=103.7, 当流量等于40.23m3/h时, Nuo=69.2.所以强化比=103.7/69.2=1.50实验数据处理过程:以普通管第一组数据为例孔板流量计压差ΔP=0.60kPa,进口温度t1=30.4℃,出口温度t2=67.1℃,壁面温度热电势4.59mV.已知数据及有关常数:(1)传热管内径di及流通段面积Fdi=20.0mm=0.0200mF=л(di2)/4=3.142*0.02002 /4=0.0003142m2(2)传热管有效长度L及传热面积Si L=1.00mSi=лLdi=3.142*1.00*0.0200=0.06284m2(3) t1为孔板处空气的温度,为由此值查得空气的平均密度ρ当t1=30.4℃时,ρ= kg/m3(4)传热管,测量段上空气平均物性常数的确定先算出测量段上空气的定性温度t /℃t= (t1 +t2)/2=(30.4+67.1)/2=48.8 ℃查得:测量段上空气的平均密度ρ=1.097 (kg/m3)测量段上空气的平均比热Cp=1005(J/kg·k)测量段上空气的平均导热系数λ=0.02816 (w/m·k)测量段上空气的平均黏度μ=19.5 (μPa·s)测量段上空气的平均普朗特准数的0.4 次方为:Pr0.4=0.866(5)空气流过测量段上平均体积V(m3/h)的计算:Vto=20.243*(ΔP)0.5139=15.57(m3/h)V=Vto*(273+t)/(273+ t1)=16.51(m3/h)(6) 冷热流体间的平均温度差Δtm/℃的计算:Tw=1.2705+23.518*4.59=109.2℃Δtm= Tw-t=109.2-48.8=60.4℃(7) 其余计算传热速率Q=V*ρ*Cpi*Δt/3600=15.57*1.097*1005*(67.1-30.4)/3600=185.6 wα=Q/(Δtm Si)=185.6/(60.4*0.06284)=48.9 (w/m2·℃)传热准数N u=α*di/λ=48.9*0.0200/0.0283=34.7测量段上空气的平均流速u=V/(F*3600)=16.51/(0.0003142*3600)=14.60(m/s)雷诺准数Re=di*u*ρ/μ=0.0200*14.60*1.097/0.0000195=16426.9(8)作图,回归得到准数关联式Nu=ARemPr0.4中的系数绘制两个实验的Nu—Re的关系图:。
传热实验操作步骤
气-汽对流传热综合实验装置1 实验前准备工作1.1确认储水罐和蒸汽发生器间的阀门处于打开状态。
1.2检查储水槽中水位不低于储水罐的1/2。
1.3 检查并确认两根被测管路上的阀门及空气旁路阀均处于关闭状态。
2 光滑套管传热实验2.1 打开通向光滑套管的蒸汽支路阀6,接通电源总开关。
按“<”控制数字位置,趁绿色圆点闪烁时用“∧∨”控制数字大小,设置加热电压为200 V。
启动电加热器,开始加热,注意加热电压不超过200V。
2.2 当光滑套管换热器的放空口9有水蒸气冒出时(此时壁温>99℃),全开空气流量旁路阀14和光滑套管的空气进气阀11,启动风机。
如果放空口9的水蒸气量过大,可以调节加热电压为170-180 V。
2.3用放空阀14来调节空气流量,调好某一流量稳定5分钟后,分别记录空气的流量、空气进口温度、空气出口温度及壁面温度。
一般从小流量到最大流量之间要测量6组数据。
实验过程中,注意不要被蒸汽管路烫伤。
3 强化管传热实验3.1检查储水罐中的水位是否正常,如果发现水位过低,应及时补给水量。
3.2 打开通向强化管的蒸汽支路阀5,关闭蒸汽支路阀6。
3.3 全部打开空气旁路阀14,打开强化套管的空气进气阀12,关闭空气支路阀11,进行强化管传热实验。
实验步骤同步骤2.3。
3.4 加热电压不超过200V。
4结束4.1 实验结束后,依次关闭加热电源,待光滑套管和强化管的壁面温度在50℃以下后,关闭风机和总电源。
4.2 关闭装置中两根被测管路上的阀门及空气旁路阀门。
附:补充资料20℃时空气流量,单位m3/h传热管内径d = 20.00 mm传热管有效长度L = 1.20 m实验需要计算强化比。
注意:实验说明书在第一个抽屉,用完请放回;打扫完卫生请填写打扫记录,老师在原始数据上签字后方可离开。
基础仪器实验室 2009年03月11日。
气—气传热综合实验操作讲义
深对其概念和影响因素的理解,并应用线性回归分析方法,确定关联式 Nu = A * Re * Pr实验研究,测定其准数关联式 Nu = B * Re 中常数 B 、m 的值和强化比 Nu / Nu 0 ,了解强化② 对α i 的实验数据进行线性回归,求关联式 Nu=ARe Pr 中常数 A 、m 的值。
② 对α i 的实验数据进行线性回归,求关联式 Nu=BRe 中常数 B 、m 的值。
气—气传热综合实验讲义一、 实验目的:1. 通过对空气—水蒸气简单套管换热器的实验研究,掌握对流传热系数 α i 的测定方法,加m 0.4中常数 A 、m 的值;2. 通过对管程内部插有螺旋线圈和采用螺旋扁管为内管的空气—水蒸气强化套管换热器的m传热的基本理论和基本方式;3. 了解套管换热器的管内压降 ∆p 和 Nu 之间的关系;二、 实验内容:实验一:① 测定 5~6 个不同流速下简单套管换热器的对流传热系数α i 。
m 0.4③ 测定 5~6 个不同流速下简单套管换热器的管内压降 ∆p 1。
实验二:① 测定 5~6 个不同流速下强化套管换热器的对流传热系数α i 。
m③ 测定 5~6 个不同流速下强化套管换热器的管内压降 ∆p 2 。
并在同一坐标系下绘制普通管∆p 1 ~Nu 与强化管 ∆p 2 ~Nu 的关系曲线。
比较实验结果。
④ 同一流量下,按实验一所得准数关联式求得 Nu 0,计算传热强化比 Nu/Nu 0。
三、 实验原理实验一 普通套管换热器传热系数及其准数关联式的测定1. 对流传热系数α i 的测定对流传热系数α i 可以根据牛顿冷却定律,用实验来测定。
式中:α i —管内流体对流传热系数,W/(m ·℃);S i —管内换热面积,m ;t i1 + t i 2V i ρ i式中:Vi —冷流体在套管内的平均体积流量,m / h ;ρi —冷流体的密度,kg /m 。