PHE450HK3330JR05中文资料

合集下载

维沙亚高抗性 高压金属玻璃带领导电阻说明书

维沙亚高抗性 高压金属玻璃带领导电阻说明书

VR25000003303JA 100VR37000003904JA100VR25000008204JA100VR37000002005FA100VR37000002204FA100VR25, VR37, VR68Vishay BCcomponentsHigh Ohmic / High Voltage Metal Glaze Leaded ResistorsDESIGN SUPPORT TOOLSA metal glazed film is deposited on a high grade ceramic body. After a helical groove has been cut in the resistive layer, tinned electrolytic copper wires are welded to the end-caps. The resistors are coated with a light blue lacquer which provides electrical, mechanical, and climatic protection.FEATURES•UL Approved (UL1676, file no: E171160)•Meet the safety requirements of:-IEC 60065-DIN EN 60065-VDE 0860-CQC (China)•AEC-Q200 qualified (VR25, VR37)•High pulse loading capability (maximum 10 kV)•Radial version available for VR25•Material categorization: for definitions of compliance please see /doc?99912APPLICATIONS•Where high resistance, high stability, and high reliability at high voltage are required •High humidity environment •White goods •Power supplies •Automotive electronicsNote(1)Ohmic values (other than resistance range) are available on requestTECHNICAL SPECIFICATIONSDESCRIPTION VR25VR37VR68Imperial size 020*********Resistance range (1)100 k Ω to 22 M Ω100 k Ω to 33 M Ω100 k Ω to 68 M ΩResistance tolerance ± 10 %; ± 5 %; ± 1 %Temperature coefficient ≤ ± 200 ppm/KRated dissipation, P 700.25 W 0.5 W 1.0 W Operating voltage, U max. AC/DC 1600 V 3500 V 10 000 V Operating temperature range -55 °C to +155 °CPeak permissible film temperature 155 °C Thermal resistance (R th )140 K/W 120 K/W70 K/W Insulation voltage:1 min.; U ins700 V Maximum noise (white noise)5 μV/V 2.5 μV/V 2.5 μV/V Max. resistance change atrated dissipation for resistance range, |∆R /R | max., after 1000 h1.5 %1.5 %1.5 %SAFETY REQUIREMENTS AND QUALIFICATIONSDESCRIPTIONVR25, VR37VR37VR68Safety requirements / qualifications AEC-Q200UL1676 qualification (file no: E171160)for ohmic range 510 k Ω to 11 M Ω;DIN EN 60065 (VDE 0860): 2015; clause 14.2 a);EN 60065: 2014IEC 60065: clause 14.2 a)CQCVR25, VR37, VR68Vishay BCcomponentsNote(1)See table “Temperature Coefficient and Resistance Range” for selecting correct ohmic value - tolerance combinationTEMPERATURE COEFFICIENT AND RESISTANCE RANGETYPE TCRTOLERANCERESISTANCE E-SERIES VR25≤ ± 200 ppm/K± 1 %100 k Ω to 15 M ΩE24; E96± 5 %100 k Ω to 22 M ΩE24; E96± 10 %15 M Ω to 22 M ΩE24VR37± 1 %100 k Ω to 33 M ΩE24; E96± 5 %100 k Ω to 33 M ΩE24VR68± 1 %100 k Ω to 68 M ΩE24; E96± 5 %100 k Ω to 68 M ΩE24PART NUMBER AND PRODUCT DESCRIPTIONPART NUMBER: VR25000001003FA100TYPE / SIZE VARIANT TCR RESISTANCE TOLERANCE (1)PACKAGINGSPECIAL VR25000 = VR25VR37000 = VR37VR68000 = VR680 = neutral0 = standard3 digit value 1 digit multiplier MULTIPLIER 0 = *1001 = *1012 = *1023 = *1034 = *1045 = *1056 = *106F = ± 1 %J = ± 5 %K = ± 10 %A1AC A5RD R5N400 = standardPRODUCT DESCRIPTION: VR25 1 % A1 100KVR25 1 %A1100K TYPE / SIZETOLERANCE PACKAGINGRESISTANCE VR25VR37VR68± 1 %± 5 %± 10 %A1AC A5RD R5N4100K = 100 k Ω15M = 15 M ΩPACKAGINGTYPECODE QUANTITY PACKAGING STYLEWIDTH PITCH DIMENSIONS VR25A11000Taped according to IEC 60286-1 fan-folded in a box 53 mm 5 mm 75 mm x 31 mm x 260 mm A5500053 mm 5 mm 76 mm x 105 mm x 265 mm N44000Taped according to IEC 60286-2 fan-folded in a box-12.7 mm 48 mm x 253 mm x 330 mm R55000Taped according to IEC 60286-1 on a reel 53 mm 5 mm 93 mm x 300 mm x 298 mm VR37A11000Taped according to IEC 60286-1 fan-folded in a box53 mm 5 mm 72 mm x 60 mm x 258 mm R55000Taped according to IEC 60286-1 on a reel 53 mm 5 mm 90 mm x 375 mm x 375 mm VR68AC 500Taped according to IEC 60286-1 fan-folded in a box66 mm 10 mm 82 mm x 111 mm x 256 mm RD750Taped according to IEC 60286-1 on a reel66 mm10 mm105 mm x 315 mm x 305 mmV R 5000001003F A 1002VR25, VR37, VR68 Vishay BCcomponentsDESCRIPTIONProduction is strictly controlled and follows an extensive set of instructions established for reproducibility. A homogeneous film of metal alloy is deposited on a high grade ceramic body and conditioned to achieve the desired temperature coefficient. Plated steel termination caps are firmly pressed on the metalized rods. Mostly, a special laser is used to achieve the target value by smoothly cutting a helical groove in the resistive layer without damaging the ceramics. Connecting wires of electrolytic copper plated with 100 % pure tin are welded to the termination caps. The resistor elements are covered by a light blue protective coating designed for electrical, mechanical, and climatic protection. Four or five color code rings designate the resistance value and tolerance in accordance with IEC 60062.Yellow and gray are used instead of gold and silver because metal particles in the lacquer could affect high-voltage properties.The result of the determined production is verified by an extensive testing procedure performed on 100 % of the individual resistors. Only accepted products are stuck directly on the adhesive tapes in accordance with IEC 60286-1 or for the radial versions in accordance to IEC 60286-2.MATERIALSVishay acknowledges the following systems for the regulation of hazardous substances:•IEC 62474, Material Declaration for Products of and for the Electrotechnical Industry, with the list of declarable substances given therein (1)•The G lobal Automotive Declarable Substance List (GADSL) (2)•The REACH regulation (1907/2006/EC) and the related list of substances with very high concern (SVHC) (3) for its supply chainThe products do not contain any of the banned substances as per IEC 62474, G ADSL, or the SVHC list, see /how/leadfree.Hence the products fully comply with the following directives:•2000/53/EC End-of-Life Vehicle Directive (ELV) and Annex II (ELV II)•2011/65/EU Restriction of the Use of Hazardous Substances Directive (RoHS) with amendment 2015/863/EU•2012/19/EU Waste Electrical and Electronic Equipment Directive (WEEE)Vishay pursues the elimination of conflict minerals from its supply chain, see the Conflict Minerals Policy at /doc?49037.ASSEMBLYThe resistors are suitable for processing on automatic insertion equipment and cutting and bending machines. Excellent solderability is proven, even after extended storage. They are suitable for automatic soldering using wave or dipping.The resistors are completely lead (Pb)-free, the pure tin plating provides compatibility with lead (Pb)-free and lead-containing soldering processes. The immunity of the plating against tin whisker growth, in compliance with IEC 60068-2-82, has been proven under extensive testing. The encapsulant is resistant to cleaning solvent specified in IEC 60115-1. The suitability of conformal coatings, if applied, shall be qualified by appropriate means to ensure the long-term stability of the whole system.APPROVALSThese resistors meet the safety requirements of:•UL1676 (510 kΩ to 11 MΩ); file no: E171160•IEC 60065, clause 14.2 a)•DIN EN 60065, clause 14.2 a)•VDE 0860, clause 14.2 a)•CQC, ChinaRELATED PRODUCTSFor a correlated range of Metal Film Resistors see the datasheet:“High Ohmic / High Voltage Metal Film Leaded Resistors”, /doc?30260For product that offers high power dissipation and metal oxide film technology see the datasheet:“High Power Metal Oxide Leaded Resistors”,/doc?20128Notes(1)The IEC 62474 list of declarable substances is maintained in a dedicated database, which is available at http://std.iec.ch/iec62474(2)The G lobal Automotive Declarable Substance List (G ADSL) is maintained by the American Chemistry Council, and available atVR25, VR37, VR68Vishay BCcomponentsFUNCTIONAL PERFORMANCEDeratingHot-Spot Temperature Rise ( T) as a Function of Dissipated PowerVR25VR37VR25, VR37, VR68 Vishay BCcomponentsMaximum allowed peak pulse voltage in accordance with IEC 60065, 14.2 a);50 discharges from a 1nF capacitor charged to Ûmax.; 12 discharges/min (drift ∆R/R≤ 2 %)VR25VR37VR25, VR37, VR68 Vishay BCcomponentsTemperature Rise ( T) at the Lead End (Soldering Point) as a Function of Dissipated Power at Various Lead Lengths after MountingVR25VR37VR25, VR37, VR68Vishay BCcomponentsTESTS PROCEDURES AND REQUIREMENTSAll tests are carried out in accordance with the following specifications:•IEC 60115-1, generic specification (includes tests)The test and requirements table contains only the most important tests. For the full test schedule refer to the documents listed above.The tests are carried out with reference to IEC 60115-1, in accordance with IEC 60068-2-xx test method and under standard atmospheric conditions in accordance with IEC 60068-1, 5.3.A climatic category 55 / 155 / 56 is applied, defined by the lower category temperature (LCT = -55 °C), the upper category temperature (UCT = 155 °C), and the duration of exposure in the damp heat, steady state test (56 days).Unless otherwise specified the following values apply:•Temperature: 15 °C to 35 °C •Relative humidity: 45 % to 75 %•Air pressure: 86 kPa to 106 kPa (860 mbar to 1060 mbar).For performing some of the tests, the components are mounted on a test board in accordance with IEC 60115-1, 4.31.In test procedures and requirements table, only the tests and requirements are listed with reference to the relevant clauses of IEC 60115-1 and IEC 60068-2-xx test methods. A short description of the test procedure is also given.TESTS PROCEDURES AND REQUIREMENTSIEC 60115-1 CLAUSE IEC 60068-2TEST METHOD TESTPROCEDUREREQUIREMENTS PERMISSIBLE CHANGE(∆R max.)4.6.1.1Insulation resistanceU max. DC = 500 V during 1 min; V-block methodR ins min.: 10 000 M Ω4.7Voltage proof U RMS = U ins ; 60 sNo breakdown or flashover4.8Temperature coefficientAt (20 / -55 / 20) °C and (20 / 155 / 20) °C≤ ± 200 ppm/K 4.12NoiseIEC 60195VR25: max. 5 μV/V VR37: max. 2.5 μV/V VR68: max. 2.5 μV/V 4.13Short time overload Room temperature; 2.5 x ;(voltage not more than 2 x limiting voltage);10 cycles; 5 s ON and 45 s OFF∆R max.: ± 2 % R 4.1621 (Ua1)21 (Ub)21 (Uc)Robustness of terminationsTensile, bending, and torsionNo damage ∆R max.: ± 0.5 % R4.1720 (Ta)Solderability+235 °C; 2 s; solder bath method; SnPb40+245 °C; 3 s; solder bath method; SnAg3Cu0.5(before aging)Good tinning (≥ 95 % covered);no damage+235 °C; 2 s; solder bath method; SnPb40+245 °C; 3 s; solder bath method; SnAg3Cu0.5(after aging)Good tinning (≥ 95 % covered);no damage4.1820 (Tb)Resistance to soldering heat Unmounted components (260 ± 5) °C; (10 ± 1) s∆R max.: ± 0.5 % R 4.1914 (Na)Rapid change of temperature30 min at -55 °C and 30 min at +155 °C;5 cycles ∆R max.: ± 0.5 % R 4.2029 (Eb)Bump 3 x 1500 bumps in 3 directions; 40 g No damage ∆R max.: ± 0.5 % R 4.226 (Fc)Vibration 10 sweep cycles per direction;10 Hz to 2000 Hz;1.5 mm or 200 m/s 2No damage ∆R max.: ± 0.5 % R4.23Climatic sequence:R ins min.: 1 G Ω∆R max.: ± 1.5 % R4.23.2 2 (Bb)Dry heat 16 h; 155 °C 4.23.330 (Db)Damp heat cyclic 24 h; 25 °C to 55 °C;90 % to 100 % RH4.23.4 1 (Ab)Cold 2 h; -55 °C 4.23.513 (M)Low air pressure 2 h; 8.5 kPa;15 °C to 35 °C4.23.630 (Db)Damp heat remaining cyclic5 days; 55 °C;95 % to 100 % RH; 5 cycles P 70 x RVR25, VR37, VR68Vishay BCcomponentsDIMENSIONSVR25 WITH RADIAL TAPINGLead Spacing (F = 4.8 mm), Size 02074.2478 (Cab)Damp heat(steady state)56 days; 40 °C;90 % to 95 % RH; loaded with 0.01 P 70(steps: 0 V to 100 V)∆R max.: ± 1.5 % R 4.25.1Endurance (at 70 °C)1000 h; loaded with P 70 or U max.;1.5 h ON and 0.5 h OFF ∆R max.: ± 1.5 % R 4.26Active flammability “cheese-cloth test”Steps of:5 / 10 / 16 / 25 / 40 x P 70 duration 5 minVR25: no flaming of gauze cylinder VR68: no flaming of gauze cylinder 4.35Passive flammability “needle-flame test”Application of test flame for 20 sNo ignition of product;no ignition of under-layer;burning time less than 30 sDIMENSIONS - Leaded resistor types, mass, and relevant physical dimensionsTYPE Ø D max. (mm)L 1 max. (mm)L 2 max. (mm)Ø d (mm)MASS (mg)VR25 2.5 6.57.50.58 ± 0.05212VR37 4.09.010.00.70 ± 0.03457VR686.818.019.00.78 ± 0.051690TESTS PROCEDURES AND REQUIREMENTSIEC 60115-1 CLAUSE IEC 60068-2TEST METHOD TEST PROCEDUREREQUIREMENTS PERMISSIBLE CHANGE(∆R max.)L dDIMENSIONS in millimetersPitch of components P 12.7 ± 1.0Lead spacing F 4.8 + 0.7 / - 0.0Width of carrier tape W 18.0 ± 0.5Body to hole centerH 19.5 ± 1.0Height for cutting (max.)L 11Height for bending H 016.5 ± 0.5Component height (max.)H 129VR25, VR37, VR68 Vishay BCcomponentsHISTORICAL 12NC INFORMATION•The resistors have a 12-digit numeric code starting with -2322 241 refers to VR25-2322 242 refers to VR37-2322 244 refers to VR68•The subsequent first digit for 1 % tolerance products (E24 and E96 series) or 2 digits for 5 % (E24 series) and 10 % (E12 series) indicate the resistor type and packing•The remaining digits indicate the resistance value:-The first 3 digits for 1 % or 2 digits for 5 % and 10 % tolerance products indicate the resistance value-The last digit indicates the resistance decadeLast Digit of 12NC Indicating Resistance DecadeHistorical 12NC Example•The 12NC for a VR25, resistor value 7.5 MΩ, 5 % tolerance, supplied on a bandoleer of 1000 units in ammopack, is: 2322 241 13755.•The 12NC for a VR37, resistor value 7.5 MΩ, 5 % tolerance, supplied on a bandoleer of 1000 units in ammopack, is: 2322 242 13755.•The 12NC for a VR68, resistor value 7.5 MΩ, 5 % tolerance, supplied on a bandoleer of 500 units in ammopack, is: 2322 244 13755.RESISTANCE DECADE LAST DIGIT100 kΩ to 976 kΩ41 MΩ to 9.76 MΩ5≥ 10 MΩ612NC CODING FOR VR25, VR37, VR68 - Resistor type and packagingTYPE TOLERANCE(%)VR25 CODING STARTS WITH 2322 241 .....VR37 CODING STARTS WITH 2322 242 .....VR68 CODING STARTS WITH 2322 244 .....BANDOLIER IN AMMOPACK BANDOLIER ON REEL RADIAL TAPED STRAIGHT LEADS4000 UNITS52 mm52 mm66.7 mm52 mm66.7 mm1000 UNITS5000 UNITS500 UNITS5000 UNITS750 UNITSVR25± 10....8....7....- 6....-± 536...13...53...-23...-± 1038...12...52...-22...-VR37± 1-8....-- 6....-± 5-13...--23...-VR68± 1---8....- 6....± 5---13...-23...Legal Disclaimer Notice VishayDisclaimerALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROV E RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.V ishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product.Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.Statements regarding the suitability of products for certain types of applications are based on Vishay's knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer's responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer's technical experts. Product specifications do not expand or otherwise modify Vishay's terms and conditions of purchase, including but not limited to the warranty expressed therein.Hyperlinks included in this datasheet may direct users to third-party websites. These links are provided as a convenience and for informational purposes only. Inclusion of these hyperlinks does not constitute an endorsement or an approval by Vishay of any of the products, services or opinions of the corporation, organization or individual associated with the third-party website. Vishay disclaims any and all liability and bears no responsibility for the accuracy, legality or content of the third-party website or for that of subsequent links.Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.© 2022 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVEDRevision: 01-Jan-20221Document Number: 91000VR68000001003JA C00VR68000001504JA C00VR25000003303JA 100VR37000003904JA100VR25000008204JA100VR37000002005FA100VR37000002204FA100。

EEEHP1A100R中文资料(panasonic)中文数据手册「EasyDatasheet - 矽搜」

EEEHP1A100R中文资料(panasonic)中文数据手册「EasyDatasheet - 矽搜」

61
0.50 EEEHB0G101R
82
0.50 EEEHB0G151P
82
0.50 EEEHB0G221P
26
0.30 EEEHB0J220R
29
0.30 EEEHB0J330R
46
0.30 EEEHB0J470R
71
0.30 EEEHB0J101P
150
0.35 EEEHB0J221P
230
0.35 EEEHB0J331P
00 Nov. 2012
芯片中文手册,看全文,戳
铝电解电容器/ HB
■ 标准产品
W.V.
Cap. (±20 %)
机箱尺寸
Dia. 长度
尺寸 代码
(V) (µF) 47
(毫米) (毫米)
4
5.8
B
100
5
5.8
C
4
150
6.3
5.8
D
220
6.3
5.8
D
22
4
5.8
B
33
4
5.8
B
500
(2)
500
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately.DΒιβλιοθήκη 25478

Parker Hose 产品目录说明书

Parker Hose 产品目录说明书

More of what you need to work smarter,AccessoriesV i s u a l I n d e x59RG D-17T1RG D-17Partek Sleeve D-18ParKoil™ (PG) D-19GuardsO-Rings for CA, CE,CF MetricFlange “D” Rings Caterpillar ® Style FlangesT ube O-Ring Fittings and CompressorFittingsO-Rings for Compression Fittings (IT126)O-Rings for C9, OC, 1C Metric Swivels88HC-H Clamp D-2488DB Clamp D-24Hose Assembly D-26Workstations3/4 Reel Rack D-2772B-Cabinet D-28HR6 Hose Bin D-28Hose Adapters D437° Flare Metric Triple-Lok ®Sizes: 6 mm – 38 mmMaterials : Steel, Stainless Steel Pressures : Up to 7200 psi60° Cone BSPPK4Sizes : 1/8” – 2”Materials : Steel Pressures : Up to 5000 psi30° Flare Komatsu StyleSizes : M14 x 1.5 – M33 x 1.5Materials : Steel Pressures : Up to 4000 psiO-Ring Face-Seal Metric Seal-Lok™Sizes: 1/4” – 2”Materials: Steel, Stainless Steel Pressures: Up to 9200 psiJapanese Industrial Standard JISSizes : 1/4” – 1”Materials : Steel Pressures : Up to 5000 psiWhen ordering Parker Adapters, please state the Catalogued Number of each type of adapter desired. Be sure to double check tube and hose sizes of items required.To select proper seal materials for specific applications, refer to Media Compatibility Chart in Tube Fitting Catalog 4300, or contact your Parker Tube Fitting Distributor.If in doubt about which type or size of fitting to specify, consult your Parker Tube Fitting Distributor. In addition Parker Field Sales, Technical Services,the Tube Fitting Division and your local Parker Service Center will help you find answers to all your issues.Phone: (614) 279-7070Fax: (614) 279-7685Web: /tfdNote: Refer to Parker Catalog 4300 for more detailed application information.CALL TOLL-FREE 1-800-C PARKER (1-800-272-7537)Parker Information Center for catalogs, literature or additional information.O-Ring Face-Seal Seal-Lok™ Sizes: 6 mm – 38 mm Materials: Steel, Stainless Steel Pressures: Up to 9200 psi37° Flare FittingsTriple-Lok ®Sizes: 1/8” – 2”Materials: Steel, Stainless Steel, BrassPressures: Up to 9000 psiPipe Fittings and Port AdaptersSizes: 1/8” – 2”Materials : Steel, Stainless Steel, BrassPressures : Up to 7200 psiPipe SwivelsSizes : 1/8” – 2”Materials : Steel, Stainless Steel Pressures : Up to 5000 psiConversion AdaptersSizes: 1/4” – 1-1/2”Materials : Steel, Stainless Steel Pressures : Up to 7700 psiHydraulic Flange and Flange AdaptersSizes : 3/4” – 3”Materials : Steel, Stainless Steel Pressures : Up to 6000 psi15T3SAE (Code 61) Flange – Male SAE (JIC) 37˚ FlareCaution: Do not use the T3 flange to tube or swivel nut to tube adapter in hose assembly applications inwhich pressures exceed the SAE100R2 working pressure range.17T3SAE (Code 61) Flange – Male SAE (JIC) 37˚ Flare - 45˚ Elbow19T3SAE (Code 61) Flange – Male SAE (JIC) 37˚ Flare - 90˚ Elbow39T3Male - Female Swivel - SAE (JIC) 37˚ - 90˚ Elbow41T3Male - Female Swivel - SAE (JIC) 37˚ - 90˚ Elbow - Long4AH3SAE Code 61 Flange - Male SAE (JIC) 37˚ Flare - 5000 psi Caution: Do not use the T3 flange to tube or swivel nut to tube adapter in hose assembly applications in which pressures exceed the SAE100R2 working pressure range.4FH3SAE Code 61 Flange - Male SAE (JIC) 37˚ Flare - 5000 psi -45˚ Elbow4NH3SAE Code 61 Flange - Male SAE (JIC) 37˚ Flare - 5000 psi -90˚ Elbow6AH3SAE Code 62 Flange - Male SAE (JIC) 37˚ Flare6FH3SAE Code 62 Flange - Male SAE (JIC) 37˚ Flare - 45˚ Elbow4AJMCode 61 Flange - Male Seal-Lok4FJMCode 61 Flange - Male Seal-Lok - 45˚ Elbow4NJMCode 61 Flange - Male Seal-Lok - 90˚ Elbow6NH3SAE Code 62 Flange - Male SAE (JIC) 37˚ Flare - 90˚ Elbow6NJMCode 62 Flange - Male Seal-Lok - 90˚ Elbow6FJMCode 62 Flange - Male Seal-Lok - 45˚ Elbow6AJMCode 62 Flange - Male Seal-LokNote:*5000 psi with 4A, 4F and 4N Fittings and 50H Flange Halves.There are two non-interchangeable SAE split flanges: a: S tandard or Code 61 is for 3,000psi to 5,000psi maximum, depending on size.b.H igh Pressure or Code 62 is for 6,000psi maximum, r egardless of size. The flange head is “V” notched for identification.Consult these tables to determine flange halves and flange kits specifications.High Pressure (Code 62)Standard Pressure (Code 61)Note: For use with 4A, 4F and 4N Flanges.50H5000 psi Flange Half (Code 61)Note: For use with 4A, 4F and 4N Flanges.Note: High pressure applications also require the use of Code 61 Flange End hose fittings.51HSAE Flange Half (Code 61)5050HK5000 psi Flange Kit (Code 61)5151HKSAE Flange Kit (Code 61)HFHSAE Flange Half (Code 62) HFHFHKSAE Flange Kit (Code 62) 8FHFlange Half (8000 psi)8FHFHKFlange Kit (8000 psi)DIN and ISO Metric PortsDIN (German) and ISO (International Organization for Standardization) flange heads are the same as SAE flange heads. By comparison, the ports have the same configura-tion except that the DIN and ISO Type I ports accept metric bolts. This requires specialflange halves in most sizes.Note: High pressure applications also require the use of Code 62 Flange End hose fittings.M1HDIN (ISO) Flange HalfM1M1HKDIN (ISO) Flange Kit (Code 61)M2M2HKDIN (ISO) Flange Kit (Code 62)M2HDIN (ISO) Flange Half (Code 62)711509O-Rings - SAE Thread (Compound N552-90)*711510O-Rings - Code 61 and Code 62 Flanges (Compound N552-90)**Note: F or use with petroleum base fluids, other compounds available for Phosphate Ester fluids.Please contact The Parker Hannifin Seal Group/O-Ring Division (1-800-C-PARKER) for additional information.C9RG O-Rings for CA, CE, CF MetricC9RG O-Rings for C9, OC, 1C Metric SwivelsD9DTBonded Seal for BSPP Port Fittings*Note: D 9DT must be ordered from the Tube FittingsDivision. Please contact TFD for additional size and product information.XARGFlange “D” Rings Caterpillar ®Style FlangesJ0RGO-Rings - Seal-Lok ®Note: O -Rings for use in Seal-Lok ® connections are illustrated in actual size. Part numbers for O-Ringsused in Seal-Lok ® and in SAE port connections are also listed in the table. O-Rings are supplied in Nitrile NBR compound, 90 durometer hardness.SAE 711509-4-8Seal-Lok J0RG-8-8Photo shows an actual comparison between an SAE port O-Ring (top) and a Seal-Lok ® O-Ring (bottom). They differ in both diameter and cross section.8ARGFlange “D” Rings for 76 Series Style FlangeT1RGO-Rings for Compression Fittings (1T126)Charge Ports CapsR134aR12CORGCaptive O-Ring Assembly ToolsParker’s new CORG Assembly Tools are designed to facilitate the installation of the O-Ring into the half-dovetail groove of the O-Ring face seal fitting.Note: C ORG Assembly T ools must be ordered from the T ube Fittings Division (614) 279-7070.Note: O -Rings listed are for use with petroleum base fluids. Other compounds are available for Phosphate Ester fluids by special order. For Viton ® or otherO-Ring compounds, consult Parker Hannifin, Seal/O-Rings Products Division (1-800-C-PARKER.)Bench TypeHand Type59RGO-Rings for Tube O-Ring Fittingsand Compressor FittingsNote:T he above O-Rings (RG) have HNBR compound number N1195-70 (green).Accessory Selection Guide – Partek Sleeve (AS-B, AS-Y or PS)Note: T he inside flat “A” dimension correspondswith the inside diameter “B” dimension. For example, AS-Y -13 flat surface “A” is 1.34 in. This offers a .86 in. inside diam-eter “B”. Hose with a smaller O.D. can be specified for this size sleeve. Parker 201-5 hose has a .58 in. O.D. and can easily be inserted in the Partek AS-Y -13Sleeve.Note: 1. T he dimensions shown are related to the hose outside diameter and may not fit over the fitting. For over the fitting applications, a larger sizesleeve may be required.2. Cut lengths are available. Contact your local distributor for prices ().Partek SleevePartek “PS” SleeveParker’s Partek Nylon Protective Sleeving gives you tough hose abrasion protection two ways. First, per the ISO 6945 specification, Partek has a unique tubular weave nylon construction, Partek “AS” is strong enough to withstand greater than 200,000 abrasion cycles without wearing through the fabric at any loca-tion. Partek “PS” can withstand greater than 50,000 abrasion cycles. In addition, this weave also gives an exceptionally smooth interior wall, allowing rubber hose to move freely inside the sleeve. This provides easy installation and prevents any internal abrasion problems. Partek sleeving is available in either black or yellow and in sizes to fit most hydraulic hose. Partek, the quick and easy solution to hose protection in high-abrasion areas.Temperature Range: -67°F to +248°F (-53°C to +120°C)Accessory Selection Guide – PolyGuard (HG)• S hield hose from abrasion and cuts • Minimize kinking• Cannot rust or corrode • R esist water, oil, gasoline, hydraulic fluid, and most solvents • I deal for bundling plastic tubing or hose lines • E asy to install without removing hose lines; no clamps neededPolyGuardHeavy-duty polyethylene provides protection in rugged operating conditions.Great for b undling high-pressure hose lines.Cut edges can be smoothed by applying heat.CAUTION: This material will support combustion.Color: BlackTemperature Range:0˚F to +200˚F (-17˚C to +93˚C)Parkoil ™Lower-cost protection for applications that call for a tighter bend radius and are less demanding.Cut edges can be smoothed by applying heat.CAUTION: This material will support combustion.Color: BlackTemperature Range:0˚F to +200˚F (-17˚C to +93˚C)Accessory Selection Guide – ParKoil ™ (PG)Accessory Selection Guide – Spring Guard and Armor GuardNote:Spring Guard and Armor Guard are packaged in 10 ft. pieces.Parker Spring Guard and Armor Guard are two products that prolong the life of hose lines that are exposed to rugged operating conditions. They distribute bending radii to avoid kinking in hose lines and protect hose from abrasion and deep cuts. Guards areconstructed of steel wire and plated to resist rust.Spring Guard (SG)Armor Guard (AG)Accessory Selection Guide – Firesleeve (FS-F)Parker Firesleeve is a flame resistant sheath that protects the hose from extreme temperature conditions. Firesleeve easily slides over hoses and readily expands over fitting. It can be assembled with Parker FSC or properly sized wormgear clamp.Construction: Braided fiberglass sleeve and an orange,bonded and seamless silicone rubber cover.Specifications: Conforms to SAE Aerospace Standard 1072A Type 2A.Temperature Range:-54˚C to +260˚C (-65˚F to +500˚F).Note: T he Firesleeve inside dimension (I.D.)must exceed the outside diameter (O.D.) of the hose and offer an allowance for easy hose insertion. For example, 201-16 has a 1.23 in. O.D. FS-S-24, with an I.D. of 1.46 in., is the suggested Firesleeve. Note: P arker FSC Clamp fits all hoses up to2 in. O.D. Note: P arker HC Clamps (wormgear) are listedon page D-24.Note: See Page D-22 for Firesleeve assembly instructions.Firesleeve (FS-F)FSC ClampPart Number: FSC(One size fits all hoses up to 2 inch O.D.)Accessory Selection Guide – Firesleeve (cont.)1. A ssemble one end fitting on hose. Cut firesleeve to same length as hose. Cover approximately 1” of each end of fire-sleeve with FSS sealant and allow to dry.2. P ush firesleeve back from cut end of hose and assemble the second end fitting. Then pull firesleeve completely over both sockets.3. I nsert tail of FSC clamp into FST clamping tool.4. P osition clamp around middle of socket and tighten with tool. Bend end of band back over buckle. Repeat on other end.Repair any scuffs or abrasions in firesleeve with FSS sealant.FSC ClampUsed to attach firesleeve around socket on hose sizes with a 2” maximum O.D.FST Clamp ToolPart Number: FST -711617 Used to secure FSC clamp.FSS Firesleeve SealantKeeps end of firesleeve from fraying - for neater, longer lasting installation.FiresleeveAssembly InstructionsAccessory Selection Guide – CL ClampVinyl coated steel clamps provide hose support where long lengths are used. Provides neater installation of hose lines, minimizes hose chafing and prevents damage to hose.Material: CR Steel with Zinc PlatingCoating: Black Vinyl Plastisol - 0,8 mm (0.03 inch) thick.Temperature Range:-40°C to +107°C (-40°F to +225°F).Accessory Selection Guide – HC, 88HC-H and 88DB ClampThe Parker HC Clamp is a stainless steel worm gear clamp designed for low presure industrial hose applications.Material: Stainless steelSpecifications: SAE J1508, Type F and Type HD88HC-HSeries Hose Clamp(High Torque Wormgear)88DBSeries Heavy Duty Hose Clamp(Double Bolt Hose Clamp)HC Hose Clamp TableNote: See 88 Series Assembly Instructions for proper 88HC-H clamp attachment.Accessory Selection Guide – Protection Shields (HP , HT, and HP-B)Prevent hose abrasion while extending your hose life. Parker Hose Protection Shields extend hose life by protecting the hose from abrasion that occurs when hose rubs against other hose, metal or concrete. Parker hose shields are resistant to oil, lubricants, gasoline, most solvents and can withstand ambient temperatures from -40° to +300° F . Easily installed and secured by cable ties without disconnect-ing any hose lines. Use with hose from 1/4” to 2” I.D.♦ Eliminate hose abrasion on concrete, metal or any rough surface. ♦ Guard against hose deterioration on mobile hydraulic equipment. ♦Let Parker fill all your hydraulic and pneumatic hose product needs.Hose Protector Shields are a fast and extremely cost effective way to isolate fluid lines from direct contact with other lines, components or structural members. They’re available in 4-inch, 6-inch and 8-inch lengths and the width can be trimmed to satisfy a variety of situations. These flexible protectors simply clamp around the hose and are securely held in place by nylon cable ties which are included. The cable ties are recessed in molded grooves to protect them from abrasion. You don’t need to disconnect a line to install a Parker Hose Protector Shield the way you do with a continuous tubular sleeve. Just wait until the installation is up and running to see exactly where contact needs to be prevented.Parker Hose Protector Shields are available in bulk quantities and in convenient assortments in 4”, 6” and 8” sizes. Cable ties are included with all protectors and are also available in bulk.Hose ShieldsTie Wraps HP-B-13X18-KIT2 ea. HP-13 RFL HT -12-KIT 30 ea. HT -12 Tie Wraps 2 ea. HP-15 RFL HT -16-KIT 30 ea. HT -16 Tie Wraps4 ea. HP-18 RFLHT -22-KIT15 ea. HT -22 Tie Wraps20 Hose Protectors and 60 Tie Wraps for each size are in point of purchase display box.HP-B-13-RFL 10 ea. HP-B-13 Hose Protectors (4”). 30 ea. HT -12 Tie Wraps in a sealed plastic bag.HP-B-15-RFL10 ea. HP-B-15 Hose Protectors (6”). 30 ea. HT -16 Tie Wraps in a sealed plastic bag.HP-B-18-RFL5 ea. HP-B-18 Hose Protectors (8”). 15 ea. HT -22 Tie Wraps in a sealed plastic bag.Contact your authorized Parker Hose Products Distributor for pricing and delivery information.Note: Parker Hose Protector Shield products are intended to prevent damage. They are not suitable as patches or repairs for lines which are already damaged or worn beyond safe use standards.Counter DisplayThe complete on-site complete hose assembly workstation design (above) includes:• TH7-5-C—6’ table with 1 hose reel and 1 bottom shelf • TH7-6—16 hose reel system, with rotating base • T H7-7—15” wide table set up for Parker 239 or 339 Cut-Off Saw Specifications: HoseFab Table (heavy duty)• Laminated wood table top • 1-1/2” square tubing structure • Gussetted corner braces • 6-leg design• All legs have adjustable feet • Hose reel/shelf combinations• 40B-Cabinet or 72B-Cabinet for fitting storage • Optional: Hose trough for measurement of hose • Calibrated to line up to Saw Table • Adjustable stop for standard length cuts• Built-in tape measureSpecifications: Rotary Reel Rack (TH7-6)• 16 Hose reel capacity • Compact design• Rotates for 1 man use• Center post bolts to floor in 4 places • Optional: Overhead craneSpecifications: Saw Table (TH7-7)• Calibrated to line up to Hose trough • Adjustable feet• Mounts to 6-foot benchSpecifications: 3 or 4 Reel Rack • Free standing 3 reel rack (TH7-8)• Bolts to floor• Optional: 4th reel capacity with wall mounts (TH7-8-F)• (2) 40B-Cabinet 40 openings - 4·1/2” x 4·1/2” x 12” in size • TH7-6-C—Optional overhead crane • T H7-5-HT—Optional 6’ measured hose trough with ad -justable hose stopPictured left is a complete on-site hose assembly workstation, the Parker Kart:The Parker Kart, TH7-4, is a portable all-in-one unit designed to hold a Minikrimp, Karrykrimp, Karrykrimp 2, or Parkrimp 1; a 332T -115V Cut-off Saw; 4 reels of hose; and has a 40 bin cabinet with 3 drawers for tools. The TH7-4 can be customized to fit your specific hose assembly needs. Contact Parker HPD or your Parker Hose distributor for details.Note: Part number TH7-4 does not include hose, fittings or equipment.Note: Part number and specifications of components for both workstations are listed on the following pages.HPD Hose Assembly WorkstationsHose Products Division has set up an agreement to allow Hose Products customers to purchase directly from our vendor, Safety Step.Safety Step’s contact information is:Safety Step Annette Cox 888-448-4237*********************See Safety Step contact information at the top of this pageSaw TableFeaturesThe Saw Table, specially designed for Parker 239 or 339 Hose Cut-Off Saw, attaches directly to the HoseFab Table.Part Number DescriptionTH7-715” wide table set up for Parker 239 or 339 Cut-Off Saw Table measurements:H eight - 18” Width - 28”Length - 14”3/4 Reel RackFeaturesCompact in its design, the standard version will hold 3 reels of hose. Optional 4th reel capacity designed with wall anchor mounts.P art Number DescriptionTH7-8 Upright 3 hose reel rackTH7-8-FO ptional extension with wall anchor for 4th reel Rack measurements:Height - 59” (82·1/2” with 4th reel option) Width - 27·3/4”Length - 27·1/2”HoseFab TableFeaturesHeavy duty constructed table for mounting Minikrimp, Karrykrimp, Karrykrimp 2, or Parkrimp 1. HoseFab Table is available in 3 versions to meet your require-ments. Options include two 40B-Cabinets or 72B-Cabinets for fitting storage.Part Number Description TH7-5-R 6’ table with 2 hose reels TH7-5-S 6’ table with 2 bottom shelves TH7-5-C 6’ table with 1 hose reel and 1 bottom shelf TH7-5-HT O ptional 6’ measured hose trough with adjustable hose stop 40B-Cabinet 40 openings - 4·1/2” x 4·1/2” x 12” in size 72B-Cabinet 72 openings - 4·1/2” x 4·1/2” x 12” in size Table measurements: Height - 31-3/4” Width - 29”Length - 72”Rotary Reel RackFeatures16 Hose reel capacity that fits in a compact area. Supplied with heavy duty casters which allow for ease of turning, even when fully loaded. Optional overhead crane available.Part Number DescriptionTH7-6 16 hose reel system, with rotating base TH7-6-C Optional overhead craneRack measurements:Height - 104” (120” with optional overhead crane) Width - 67”Length - 67”See Safety Step contact information on page D-26See Safety Step contact information on page D-26See Safety Step contact information on page D-26See Safety Step contact information on page D-26Parker Kart Part No. TH7-4Parker Kart organizes and stores all your necessary Parker hoses, fittings, power and hand tools - everything you need to make fast hose assemblies on site. As a valued addition to any facility, Parker Kart will save on downtime and labor costs, as well as eliminate errors in cutting and fitting attachment. With Parker Kart, you’ll always have the materials you need, right when and where you need them.• Easy one-man movement• Eight-inch urethane casters with brakes• Forklift carry tubes• Electric receptable with cord• Fitting bins and drawers• Large tool drawer• Four hose reel holders• Choice of Parker crimping equipment• Optional accessories availableParker Kart can be customized to fit specific hose assem-bly needs. Parker Kart does not include hose, fittings orequipment.Fitting Stock Bins72B-Cabinet36” wide, 43” high, 12” deep, with 72 openings each 4-1/2”x 4-1/2” x 12”, heavy duty steel, all welded construction.Product bin labels are available.Hose Stock BinsHR6-Hose-BinRugged metal cabinet for stocking coils of Parker hose 36”wide, 28” high, 20” deep, with upright separators to provide6 compartments varying in width from 4” to 8”.Provides suitable base on which to place the fittings stockbin (top measures 36” x 20”, bottom of fittings bin measures36” x 12”.)Yellow with black “Parker Hose” lettering.See Safety Step contact information on page D-26。

英飞凌 FF450R33T3E3 XHP 3 模块 数据表

英飞凌 FF450R33T3E3 XHP 3 模块 数据表

XHP ™3 模块 采用第三代沟槽栅/场终止IGBT3和第三代发射极控制二极管特性•电气特性-V CES = 3300 V-I C nom = 450 A / I CRM = 900 A -低开关损耗-高直流电压稳定性-高短路能力-低 V CEsat-T vj op = 150°C -无与伦比的坚固性-V CEsat 带正温度系数•机械特性-碳化硅铝 (AlSiC) 基板提供更高的温度循环能力-绝缘的基板-封装的 CTI > 600可选应用•中压变流器•电机传动•牵引变流器•UPS 系统•风力发电机产品认证•根据 IEC 60747、60749 和 60068标准的相关测试,符合工业应用的要求。

描述FF450R33T3E3XHP ™3 模块内容描述 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1特性 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1可选应用 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1产品认证 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1内容 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 1封装 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2IGBT, 逆变器 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 3二极管,逆变器 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 4特征参数图表 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 5电路拓扑图 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 6封装尺寸 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 7模块标签代码 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13修订历史 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14免责声明 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .151封装表 1绝缘参数特征参数代号标注或测试条件数值单位绝缘测试电压V ISOL RMS, f = 50 Hz, t = 60 s 6.0kV 局部放电熄弧电压V isol RMS, f = 50 Hz, Q PD≤ 10 pC 2.6kV 模块基板材料AlSiC爬电距离d Creep端子至散热器53.0mm 爬电距离d Creep端子至端子53.0mm 电气间隙d Clear端子至散热器36.0mm 电气间隙d Clear端子至端子26.0mm 相对电痕指数CTI > 600表 2特征值特征参数代号标注或测试条件数值单位最小值典型值最大值杂散电感,模块L sCE25nH 模块引线电阻,端子-芯片R AA'+CC'T C=25°C, 每个开关0.31mΩ模块引线电阻,端子-芯片R CC'+EE'T C=25°C, 每个开关0.41mΩ储存温度T stg-40150°C 模块安装的安装扭距M根据相应的应用手册进行安装M6, 螺丝 4.25 5.75Nm端子安装扭矩M根据相应的应用手册进行安装M3, 螺丝0.9 1.1Nm M8, 螺丝810重量G700g 2IGBT, 逆变器表 3最大标定值特征参数代号标注或测试条件数值单位集电极-发射极电压V CES T vj = -40 °C3300VT vj = 150 °C3300连续集电极直流电流I CDC T vj max = 150 °C T C = 100 °C450A 集电极重复峰值电流I CRM t p受限于 T vj op900A 栅极-发射极峰值电压V GES±20V表 4特征值特征参数代号标注或测试条件数值单位最小值典型值最大值集电极-发射极饱和电压V CE sat I C = 450 A, V GE = 15 V T vj = 25 °C 2.50 2.75VT vj = 125 °C 2.90T vj = 150 °C 3.00 3.30栅极阈值电压V GEth I C = 12 mA, V CE = V GE, T vj = 25 °C 5.20 5.80 6.40V 栅极电荷Q G V GE = ±15 V, V CE = 1800 V12.5µC 内部栅极电阻R Gint T vj = 25 °C 1.3Ω输入电容C ies f = 1000 kHz, T vj = 25 °C, V CE = 25 V, V GE = 0 V84nF 反向传输电容C res f = 1000 kHz, T vj = 25 °C, V CE = 25 V, V GE = 0 V2nF 集电极-发射极截止电流I CES V CE = 3300 V, V GE = 0 V T vj = 25 °C5mA 栅极-发射极漏电流I GES V CE = 0 V, V GE = 20 V, T vj = 25 °C400nA开通延迟时间(感性负载)t don I C = 450 A, V CE = 1800 V,V GE = ±15 V, R Gon = 0.7 ΩT vj = 25 °C0.530µs T vj = 125 °C0.570T vj = 150 °C0.580上升时间(感性负载)t r I C = 450 A, V CE = 1800 V,V GE = ±15 V, R Gon = 0.7 ΩT vj = 25 °C0.100µs T vj = 125 °C0.130T vj = 150 °C0.130关断延迟时间(感性负载)t doff I C = 450 A, V CE = 1800 V,V GE = ±15 V, R Goff = 3.3 ΩT vj = 25 °C 1.710µs T vj = 125 °C 1.860T vj = 150 °C 1.920下降时间(感性负载)t f I C = 450 A, V CE = 1800 V,V GE = ±15 V, R Goff = 3.3 ΩT vj = 25 °C0.130µs T vj = 125 °C0.240T vj = 150 °C0.270开通时间(阻性负载)t on_R I C = 500 A, V CE = 2000 V,V GE = ±15 V, R Gon = 0.7 ΩT vj = 25 °C 1.15µs开通损耗能量 (每脉冲)E on I C = 450 A, V CE = 1800 V,Lσ = 85 nH, V GE = ±15 V,R Gon = 0.7 Ω, di/dt =3650 A/µs (T vj = 150 °C)T vj = 25 °C500mJ T vj = 125 °C765T vj = 150 °C845关断损耗能量 (每脉冲)E off I C = 450 A, V CE = 1800 V,Lσ = 85 nH, V GE = ±15 V,R Goff = 3.3 Ω, dv/dt =2850 V/µs (T vj = 150 °C)T vj = 25 °C415mJ T vj = 125 °C610T vj = 150 °C670(待续)表 4(续) 特征值特征参数代号标注或测试条件数值单位最小值典型值最大值短路数据I SC V GE≤ 15 V, V CC = 2500 V,V CEmax=V CES-L sCE*di/dt t P≤ 10 µs,T vj≤ 150 °C1800A结-外壳热阻R thJC每个 IGBT28.4K/kW 外壳-散热器热阻R thCH每个 IGBT, λgrease= 1 W/(m*K)17.4K/kW 允许开关的温度范围T vj op-40150°C3二极管,逆变器表 5最大标定值特征参数代号标注或测试条件数值单位反向重复峰值电压V RRM T vj = -40 °C3300VT vj = 150 °C3300连续正向直流电流I F450A 正向重复峰值电流I FRM t P = 1 ms900A I2t-值I2t t P = 10 ms, V R = 0 V T vj = 125 °C82.9kA²sT vj = 150 °C68最大损耗功率P RQM T vj = 150 °C1000kW 最小开通时间t onmin10µs表 6特征值特征参数代号标注或测试条件数值单位最小值典型值最大值正向电压V F I F = 450 A, V GE = 0 V T vj = 25 °C 3.10 3.50VT vj = 125 °C 2.75T vj = 150 °C 2.65 2.95反向恢复峰值电流I RM V R = 1800 V, I F = 450 A,V GE = -15 V, -di F/dt =3650 A/µs (T vj = 150 °C)T vj = 25 °C680A T vj = 125 °C680T vj = 150 °C680恢复电荷Q r V R = 1800 V, I F = 450 A,V GE = -15 V, -di F/dt =3650 A/µs (T vj = 150 °C)T vj = 25 °C230µC T vj = 125 °C445T vj = 150 °C525(待续)表 6(续) 特征值特征参数代号标注或测试条件数值单位最小值典型值最大值反向恢复损耗(每脉冲)E rec V R = 1800 V, I F = 450 A,V GE = -15 V, -di F/dt =3650 A/µs (T vj = 150 °C)T vj = 25 °C220mJ T vj = 125 °C490T vj = 150 °C595结-外壳热阻R thJC每个二极管45.5K/kW 外壳-散热器热阻R thCH每个二极管, λgrease= 1 W/(m*K)19.3K/kW 允许开关的温度范围T vj op-40150°C5电路拓扑图Beispiel: PrimePACK-3+ CostdownCommon Collektorxx.03.2019 mit WW, Jürgen Esch36NTC 9,11,13T23,4D29651T1D187202.08.2021 Beispiel für A.Schulz10: NC图 1FF450R33T3E3XHP ™3 模块5 电路拓扑图6 封装尺寸6封装尺寸图 27 模块标签代码7模块标签代码图 3修订历史修订历史修订版本发布日期变更说明V1.02013-12-05Target datasheetV1.12014-08-25Target datasheetV1.22015-01-22Target datasheetV1.32015-10-16Target datasheetV1.42015-10-16Target datasheetV2.02016-05-18Preliminary datasheetV2.12016-09-02Preliminary datasheetV2.22016-12-23Preliminary datasheetV2.32018-02-14Preliminary datasheetV3.02018-12-12Final datasheetV3.12018-12-13Final datasheetV3.22020-01-27Final datasheetn/a2020-09-01Datasheet migrated to a new system with a new layout and new revisionnumber schema: target or preliminary datasheet = 0.xy; final datasheet =1.xy1.102021-11-04Final datasheet1.202022-04-06Final datasheet商标所有参照产品或服务名称和商标均为其各自所有者的财产。

蜂鸟电器商品说明书

蜂鸟电器商品说明书

Residential Combustion Heating and Cooling Parts Cross-Reference GuidePhone:Residential Technical Support:1-800-468-1502Sales Support: 1-800-328-5111Customer Service: 1-888-793-8193Residential Zoning: 1-800-828-8367Online:Contractor PRO:Phone: 1-800-919-4835Fax: 1-763-954-4097Exclusive Technical Supportfor Contractor PRO members:1-877-880-3383Online T oolsFind everything you need to be successful in sellingHoneywell products online. Product information,cross-references, demos and more are available at.TrainingHoneywell offers a variety of on-site and web-based training optionsat .RewardsHoneywell’s Contractor PRO™ Rewards program givescontractors reward points ($) back on all Honeywellpurchases year round at .Customer ServiceHoneywell provides toll-free access to productapplication, installation and support experts.T echnical Support: 1-800-468-1502Customer Service: 1-888-793-8193Sales LiteratureWith Honeywell, you’ll have access to sales materials that you can use tohelp grow your business. Visit .SupportHow-to-use this cross-reference The pages in this guide contain Honeywell, OEM and competitive manufacturerscontrols and the recommended Honeywell cross reference. To find your recommendedcross reference simply turn to the appropriate product section, locate your productmanufacturer and their part number and follow the row to the Honeywell part number.The cross reference data in this guide is correct to the best of Honeywell's knowledge atthe time of publication. Always refer to installation instructions for application details andto ensure correct product specifications prior to installation.Table Of ContentsGAS CONTROLSGas Valves 4SmartValve™ System Controls 18Universal Pilot Burners 19Thermocouples/Thermopiles 20Ignition Modules 21Glowfly® Universal Hot Surface Igniter 26Universal Electronic Fan Timers 27Silicon Carbide Igniters 28Universal Integrated Furnace Control 32Fan and Limit Controls 34OIL/HYDRONIC CONTROLSOil Primaries 35Aquastats® 36HEATING/COOLING DEVICESRelays/Contactors/Transformers 37Universal Product Universal4Universal Gas ValvesSave time and money by stocking the HoneywellUniversal gas valves, you'll complete more jobs and tie up less in inventory with the right selection of valves.Gas ValvesGas Valvesl5Gas ValvesGas ValvesGas Valves6Gas ValvesGas Valvesl7Gas ValvesGas ValvesGas Valves8Gas ValvesGas Valvesl9Gas ValvesGas ValvesGas Valves10Gas ValvesGas Valvesl11Gas ValvesGas ValvesGas Valves12Gas ValvesGas Valvesl13Gas ValvesGas ValvesGas Valves14Gas ValvesGas Valvesl15Gas ValvesGas ValvesGas Valves16Gas ValvesGas ValveslGas ValvesGas ValvesGas Valves1718SmartValve ™SmartValver t lUniversal SmartValvesHoneywell SmartValves combine gas flow control and electronic ignition into a single unit providing smart, safe control in appliances.19Universal Pilot BurnersSave time, money, and space with Universal Pilot Burners. 4 Universal Pilots replace over 120 different models.Universal Pilot BurnersUniversal Pilot BurnersUniversal Pilot Burners20Contractors depend on Honeywell foreasy installation and reliable performance and we think about that trust in every component we make. Built for long service life, the Honeywell Q313U, Q340A, and Q390A will work for nearly all pilot generated millivolt applications.Thermocouples/Thermopilesr l /r i l Thermocouples/Thermopiles21Ignition Modules Ignition ModulesIgnition ModulesUniversal Intermittent Pilot and Hot Surface IgnitionHoneywell's ignition controls replace a wide variety of OEM installed Honeywell and competitive products in the field. Reduce your inventory and complete moreservice jobs with Honeywell's Universal ignition controls.22Ignition ModulesI i t i l Ignition ModulesIgnition ModulesIgnition ModulesIgnition Modules2324Ignition ModulesI i t i l Ignition Modules25Ignition Modules Ignition ModulesIgnition Modules26Silicon Nitride 120V Universal Hot Surface IgniterWith 6 customized brackets, next generation Silicon Nitride and one of a kind six-pack with visual cross-reference Glowfly ® is the truck stock choice for the beready for anything contractor.Glowfly ® Universal Hot Surface IgnitersGlowfly ® Universal Hot Surface Igniterst r f I i t r27Fan TimerFan TimerFan TimerUniversal Electronic Fan TimerWith a complete set of wiring harness, field-adjustable settings and extensive cross-reference the ST9120U is a must stock item for every service van.28Honeywell offers a full line of direct replacement, 120 V, silicon carbide igniters. They cover all the major configurations of element shapes, brackets, connectors, and lead wire lengths. Made in the USA and backed by a 2-year warranty.Silicon Carbide IgnitersSilicon Carbide Ignitersi l i r i I i t r29Silicon Carbide IgnitersSilicon Carbide IgnitersSilicon Carbide Igniters30Silicon Carbide IgnitersSilicon Carbide Ignitersi l i r i I i t r31Silicon Carbide IgnitersSilicon Carbide IgnitersSilicon Carbide IgnitersBracket A Bracket CBracket BBracket DBracket E32Single-Stage 120V Hot Surface IgnitionHoneywell's Universal Integrated control provides contractors with the application flexibility and ease of use they require to get the job done fast and right, the first time!Integrated Furnace ControlsI t r t r t r l Integrated Furnace ControlsIntegrated Furnace ControlsIntegrated Furnace ControlsIntegrated Furnace Controls3334Fan and Limit ControlsFan and Limit Controlsi i t t r lHoneywell fan and limits combines hightemperature limit with circulating blower control. As an industry standard for many years, these controls have a large and varied installed base. You’ll find Honeywell fan and limits on a wide range of furnaceequipment.35Oil Primaries Oil PrimariesOil PrimariesUniversal Digital Electronic Oil PrimaryWith the most advanced features our new oil primary helps you optimize your service department by telling you what's wrong up front, so you'll spend less time diagnosing systems and more time keeping yourcustomers comfortable and happy.36Aquastat ®t tAquastatHoneywell AquastatsA boiler industry standard, Honeywell Aquastats have a proven track record and a large installed base, keep your customers' heat on all winter with our Universalelectronic Aquastats.*All members of crossed family can be replaced.37Heating and Cooling ComponentsHeating and Cooling ComponentsHeating and Cooling Components Honeywell offers a full lineup of contactors, relays and transformers for all yourresidential HVAC applications.38Heating and Cooling Componentst i l i t Heating and Cooling Components39Heating and Cooling Components Heating and Cooling ComponentsHeating and Cooling ComponentsLearn MoreCall 1-800-468-1502e-mail ******************or visit Automation and Control SolutionsIn the U.S.:Honeywell1985 Douglas Drive NorthGolden Valley, MN 55422-3992 67-7518 PRJuly 2015© 2015 Honeywell International Inc.YouTube:@honeywellcpro。

高科特实际产品说明书

高科特实际产品说明书

4
Specifications are subject to change without notice (21.06.2021)
Solid State Relays Accessories, Screw Kits Types SRWKIT…
Ordering Key
Screw Kit Screw size Screw length
0.5 Nm -20° to + 70°C [-4 to +158°F] -40° to + 100°C [-40° to +212°F] DIN EN 50022, 50035
DIN Adaptor for 1-phase SSRs
DIN rail adaptor module for mounting the 1-phase SSR series RA, RD, RM, RS and RAM directly on DIN rail.
Type
UL style 2547 UL style 2464 UL style 2464 UL style 2464 UL style 2464 UL style 2464
Cable size
0.14mm2 0.14mm2 0.14mm2 0.25mm2 0.14mm2 0.14mm2
Termination
- Width x Height x Thickness = 35 x 43 x 0.25 mm
- Packing qty. 50 pcs.
RZHT
- Graphite thermal pad for RZ3 series with adhesive on one side
- Width x Height x Thickness = 70 x 77 x 0.25 mm

Lincoln Magnum PRO Curve 450 商品说明书

Lincoln Magnum PRO Curve 450 商品说明书

Operator’s ManualRegister your machine:/registerAuthorized Service and Distributor Locator: /locatorIM10416| Issue D a te Aug-17© Lincoln Global, Inc. All Rights Reserved.For use with Code Numbers:K3518-2, K3518-2-8-45, K3518-2-10-45Save for future referenceDate PurchasedCode: (ex: 10859)SECTION A:WARNINGSC ALIFORNIA PROPOSITION 65 WARNINGSWARNING: This product, when used for welding or cutting, produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer. (California Health & Safety Code § 25249.5 et seq.)ARC WELDING CAN BE HAZARDOUS. PROTECTYOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY.PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.BE SURE THAT ALL INSTALLATION, OPERATION,MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.FOR ENGINE POWERED EQUIPMENT.1.a.Turn the engine off before troubleshootingand maintenance work unless themaintenance work requires it to be running.1.b.Operate engines in open, well-ventilated areas or vent the engineexhaust fumes outdoors. 1.c.Do not add the fuel near an open flame weldingarc or when the engine is running. Stop the engine and allow it to cool before refueling to with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated.1.d. Keep all equipment safety guards, coversand devices in position and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.1.e.In some cases it may be necessary to remove safety guards toperform required maintenance. Remove guards only when necessary and replace them when the maintenance requiring their removal is complete. Always use the greatest care when working near moving parts. 1.f. Do not put your hands near the engine fan. Do not attempt tooverride the governor or idler by pushing on the throttle control rods while the engine is running. 1.g.To prevent accidentally starting gasoline engines while turningthe engine or welding generator during maintenance work,disconnect the spark plug wires, distributor cap or magneto wire as appropriate. 1.h.To avoid scalding, do not remove the radiatorpressure cap when the engine is hot.ELECTRIC ANDMAGNETIC FIELDS MAY BE DANGEROUS2.a.Electric current flowing through any conductorcauses localized Electric and Magnetic Fields (EMF).Welding current creates EMF fields around welding cables and welding machines 2.b.EMF fields may interfere with some pacemakers, andwelders having a pacemaker should consult their physician before welding. 2.c.Exposure to EMF fields in welding may have other health effectswhich are now not known. 2.d.All welders should use the following procedures in order tominimize exposure to EMF fields from the welding circuit:2.d.1.Route the electrode and work cables together - Securethem with tape when possible.2.d.2.Never coil the electrode lead around your body.2.d.3.Do not place your body between the electrode and workcables. If the electrode cable is on your right side, the work cable should also be on your right side.2.d.4.Connect the work cable to the workpiece as close as pos-sible to the area being welded.2.d.5.Do not work next to welding power source.SAFETYTABLE OF CONTENTSTechnical Specifications.........................................................................................................................................A-1Installation ..................................................................................................................................................Section A Connector Kit Installation to Gun Cable......................................................................................................................A-2 K466-1 and K466-8 Installation (for Lincoln Feeders)................................................................................................A-3 K466-2 Installation (For Tweco Adapted Feeders)......................................................................................................A-3 K466-3 Installation (For Miller feeders; i.e. Millermatic 200, Cricket, S-32P, 54D...)...................................................A-3 K466-6 and K466-10 Installation (Wirematic and Lincoln 10 Series Feeders).............................................................A-3 Liner Installation and Trimming Instructions...............................................................................................................A-4 Rotating the Gun Tube...............................................................................................................................................A-4 Contact Tip and Gas Nozzle Installation......................................................................................................................A-4 Connection to Feeder.................................................................................................................................................A-4 Connection to Lincoln Feeders...................................................................................................................................A-4 Connection to Tweco Adapted Feeders......................................................................................................................A-4 Connection to Miller Feeders.....................................................................................................................................A-5 Connection To Lincoln Wirematic, Hobart Series 2000 Feeders, Or Sp100t Type Feeders..........................................A-5 Connection To Lincoln 10 Series Feeders..................................................................................................................A-5 Consumable Thread Sizes.........................................................................................................................................A-5Operation ..................................................................................................................................................Section B Electrodes and Equipment.........................................................................................................................................B-1 Making a Weld..........................................................................................................................................................B-1 Avoiding Wire Feeding Problems................................................................................................................................B-1Maintenance..................................................................................................................................................Section C Removal, Installation and Trimming Gun Liners.........................................................................................................C-1 Gun Tubes and Nozzles.............................................................................................................................................C-1 Gun Cables ............................................................................................................................................................C-1 Cable Repair ............................................................................................................................................................C-1 Troubleshooting............................................................................................................................................Section DPARTS CONTENT/DETAILS MAY BE CHANGED OR UPDATED WITHOUT NOTICE. FOR MOST CURRENT INSTRUCTION M ANUALS, GO TO .FIGURE 2FIGURE 3.125g)Slip the connector nut over the copper strands with the threadend out. Orient gun tube connector so machined flat is on theFIGURE 4 Pull the cut-off lead terminals off the trigger assembly andWire Feeder End Repair(REQUIRES 2 #S19492-1 TERMINALS)a)Remove the cable liner per 3.1.b)Remove the feeder end connector, molded gas plug (orbarbed fitting), cable handle nut, plastic tailpiece, andconnector cover (see Figure 6).NOTE:In order to remove the cable handle nut, the tail of the connector cover must be depressed and the cable handle nut rotated 1/4 turn counterclockwise as viewed from the feeder end.c)Remove incoming connector from cable by unscrewingconnector nut from incoming connector. If the cable innertube is difficult to remove from the connector assembly,carefully slit it lengthwise with a knife up to the brassconnector.d)Move the cable boot, cable handle, and strain relief towardthe middle of the cable past the damaged section.e)Cut off the damaged section of cable and strip off the outerjacket as shown in Figure 3. Be careful not to cut theinsulation on the control wires while stripping jacket. Stripthe red and white control leads 1/4" (6.4 mm) from the endand crimp a new S19492-1 terminal to each lead. Trim theinner tube to dimensions shown.NOTE:The cable contains four control leads. Any two control leads can be used, provided the two colors used are the same at both ends. The extra leads are spares that can be used if one of the other leads breaks.f)Check that the cable boot, cable handle and strain relief areon the cable. Slip the connector nut over the copper strands with the threaded end out. Assemble incoming connector tocable by forcing the steel tube of the connector into the inside diameter of the cable inner tube until the copper strands are butted against the incoming connector shoulder. Keeping the copper strands against the shoulder, pull the connector nutover the copper strands, engage the incoming connectorthreads, and tighten in place. Refer to Figure 4.NOTE:For best results, insert a .250" (6.4mm) diameter rod through the connector and into core of cable approximately11.00" (280 mm) when pushing the connector tube into thecable core tube. To tighten, hold the connector in place while turning the nut, then remove the rod from the core. Thisprocedure assures the inner core does not kink whileassembling or tightening.Position the plastic strain relief such that the tapered end is7.10" (180 mm) from the incoming connector (see Figure 6).Lock into place with steel housing.g)Position cable boot and cable handle on cable and assemblereplacement control wire terminals in place on the cablehandle. Insert connector cover in place. Install tailpiece and fasten to cable handle with cable handle nut. Refer to Figure 6.h)Replace the molded gas plug (or barbed fitting) and feederend connector.i)Install and trim liner per Section 1.2.FIGURE 6If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourIf for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourATENÇÃOJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL FABRICANTE PARA EL USO DE ESTE EQUIPO Y LOS CONSUMIBLES QUE VA A UTILIZAR, SIGA LAS MEDIDAS DE SEGURIDAD DE SU SUPERVISOR.LISEZ ET COMPRENEZ LES INSTRUCTIONS DU FABRICANT EN CE QUI REGARDE CET EQUIPMENT ET LES PRODUITS A ETRE EMPLOYES ET SUIVEZ LES PROCEDURES DE SECURITE DE VOTRE EMPLOYEUR.LESEN SIE UND BEFOLGEN SIE DIE BETRIEBSANLEITUNG DER ANLAGE UND DEN ELEKTRODENEINSATZ DES HER-STELLERS. DIE UNFALLVERHÜTUNGSVORSCHRIFTEN DES ARBEITGEBERS SIND EBENFALLS ZU BEACHTEN.ATENÇÃOJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE PARA ESTE EQUIPAMENTO E AS PARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.customer assistance policYThe business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equipment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for advice or information about their use of our products. We respond to our customers based on the best information in our possession at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such information or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customer’s particular purpose, with respect to such information or advice. As a matter of practical consideration, we also cannot assume any respon-sibility for updating or correcting any such information or advice once it has been given, nor does the provision of information or advice create, expand or alter any warranty with respect to the sale of our products.Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control of, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in applying these types of fabrication methods and service requirements.Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to for any updated information.。

江海电容器HPF系列导电高分子固体铝电解电容器规格书说明书

江海电容器HPF系列导电高分子固体铝电解电容器规格书说明书

编号Issue No.G.HPF.202108022规格书版本号A客户版本号A0尊敬的Messrs规 格 书SPECIFICATIONS产品类型导电高分子固体铝电解电容器Product type Aluminium electrolytic capacitors with conductive polymer solid electrolyte产品系列HPFSeries南通江海电容器股份有限公司Nantong Jianghai Capacitor Co., Ltd.地址:江苏省南通市平潮镇通扬南路79号No.79 South Tongyang Road Pingchao TownNantong City Jiangsu Province PR ChinaTEL: 0086--0513--86726020 / FAX: 0086--0513--86571812日 期批 准审 核制 定Date Approved by Checked by Drawn by2021.8.5姚玉英孙何欢黄熊惑承认栏 User目录 ContentsNo.项目Item页码Page1适用范围 Scope42规格值 Specifications4~53尺寸 Dimensions54标志 Marking65构造 Structure76编码规则 Part number system77特性 Characteristics8~128包装 Packing139编带 Taping1410环保方面 Environmental1411使用注意事项 Technical note15~18G.HPF.202108022南通江海电容器股份有限公司 Nantong Jianghai Capacitor Co., Ltd.2规格书变更记录 (Change history of specification)发行日期版本原因内容页码标记发行编号Issued date Edition Reason Contents Page Mark Issue No.2021.8.5A 首次发行Original- 1 to 18-G.HPF.2021080221. 适用范围 Scope本规格书适用于HPF系列固体导电高分子铝电解电容器。

电感全型号尺寸封装

电感全型号尺寸封装

123-129
VC TYPE TC TYPE
130-133 134-141
HSMB TYPE
142-144
HSM TYRE
PART NUMBERING SYSTEM( 品名系列 )
HSM 54 -101 K –T/B
② ③ ①
② ③ ④ ⑤
①. 产品类型:产品代码。 ②. 产品尺寸:外围×高度。 ③. 电感值:前两位为有效值,第三位表零的个数。 ④. 电感公差 : J; 5℅, K: ±10℅,L: ±15℅,M: ±20℅,P: ±25℅,N: ± 30℅。 ⑤. 包装方式 : 〝T”: 载带盘装, B: 散装
±0.3 6.5
±0.3
9.5 1.5 3.7
HSM108
10.0±0.3 9.0
±0.3 8.3
±0.3
9.7 2.0 4.4
FEATURES( 特性 )
Various high power inductors are superior to be high saturation for surface mounting.
HSM42-2R7M 2.7
Equipments DC/DC Converters,etc
录放影机电源供应器 .液晶电视机 .笔记本电脑 .便携式通讯设备 .直流 /直流转换器
HSM31A/B TYPE
→电气性能 Electrical Characterisitics
PART NO. ( 品名 )
HSM31A-2R2M
INDUCTANCE(UH) 电感值
直流直流转换器parthsm31a350330021103351608hsm31b350330022003351608hsm32350330032003351608hsm424503400320034517515hsm434503400332034517515hsm52a5803520325035521517hsm52b5803520330035521517hsm53a5803520330035521517hsm53b5803520335035521517hsm545803520345035521517hsm73780370033503753020hsm75780370035003753020hsm10510003900354039537525hsm1061000390036503951537hsm1081000390038303972044hsm31abtype电气性能electricalcharacterisiticspart品名inductanceuh电感值dcr直流电阻maxidcamax最大耐电流l10testfreq测试频率hsm31a2r2m2203161khz025vhsm31a3r3m330351551khz025vhsm31a4r7m47041471khz025vhsm31a6r8m68051341khz025vhsm31a100m100061241khz025vhsm31a150m1500751221khz025vhsm31a220m2201051091khz025vhsm31a470m470250961khz025vhsm31b1r0m100052251khz025vhsm31b1r5m150065201khz025vhsm31b2r2m220067121khz025vhsm31b3r3m330271081khz025vhsm31b3r9m390831001khz025vhsm31b4r7m4711311001khz025vhsm31b5r6m561250801khz025vhsm31b8r2m821000581khz025vhsm31b100m100270751khz025vhsm31b120m120520761khz025vhsm31b150m15091051khz025vhsm31b180m181750401khz025vhsm31b220m221900351khz025vhsm31

西格里集团的特种石墨产品

西格里集团的特种石墨产品

2008 年第9期·航空制造技术103西格里集团的特种石墨产品西格里集团Special Graphite of SGL Group总部位于德国威斯巴登的西格里集团(SGL Group—The Carbon Company)是全球领先的碳素石墨材料及相关产品制造商之一,拥有从碳石墨产品到碳纤维及碳/碳复合材料在内的完整生产线。

西格里集团的核心竞争力源自其多年来在高温科技及工程应用方面积累的专业技能,这使得公司能够充分运用其广阔的原料平台。

西格里集团的碳素石墨材料具有优异的导电导热性,抗高温、抗腐蚀性,重量轻,机械强度高等特点。

现在,全球能源及原材料的短缺促进了材料进一步的更新换代,各大行业对西格里集团的高能效材料及其产品的需求量日益增长。

当钢铁、铝、铜、塑料和木材等原料由于自身物理特性限制而无法使用时,碳素及石墨产品由于其抗高温、耐腐蚀等特点而得到广泛应用,众多新兴产业如半导体、电池、太阳能/风能、环境保护、航空航天技术、国防工业以及核能工业的各大制造商也在西格里集团的客户行列之中。

作为一个国际公司,西格里集团在欧洲、北美及亚洲地区拥有38个生产基地以及覆盖100多个国家的服务网点。

2007年集团全球员工约5900人,销售额达14亿欧元。

特种石墨产品种类西格里集团特种石墨业务部可以根据客户需求,提供所需各类碳石墨电极产品。

(1)工业用碳石墨。

此类石墨主要用于制造有色金属如铜、铝等合金材料的水平连续铸造的石墨结晶器,贵稀有金属冶炼用石墨坩埚,铝液净化用石墨注气管、石墨转子以及浮法玻璃用石墨挡块,生产玻璃器皿用石墨模与石墨夹具,合成金刚石用石墨粉,铸铁棒用石墨模具以及钢材薄板带拉铸用石墨辊轮等产品。

(2)电子半导体用碳石墨。

主要用于拉制单晶硅与光纤的热场,单晶片外延处理用石墨基座,电子封装用石墨烧104航空制造技术·2008 年第9期结模,多晶铸锭用石墨等。

(3)高温用碳石墨。

主要用于粉末冶金、硬质合金、特种陶瓷等产品烧结用石墨舟皿,真空电炉用石墨发热体以及保温材料,航空航天工业用各种碳/碳复合材料等。

格瑞普镍氢电池规格书说明书

格瑞普镍氢电池规格书说明书
充电 Charge
单颗电池尺寸包括 PVC (Dimensions with tube)
()
Voltages (V)
Voltage (V)
型号(Model No.)ESP750AAH
典型特征 Typical characteristics 标准充电特征 Standard charge
Charge: 0.1C ×15hrs.
单位颗 Unit cell
*
允许循环 3 次 Up to 3 cycles are allowed
允许循环 3 次 Up to 3 cycles are allowed
1.0V/cell Cut-off
*
1.0V/cell Cut-off
*
4 制造商保留在没有预先通知的情况下改变和修正设计及规格说明书的权力
1. 序言 PREFACE
此规格书适用于深圳格瑞普电池有限公司的镍氢可充电电池产品 The specification is suitable for the performance of NI-MH rechargeable battery
2. 型号 MODEL
ESP750AAH
3. 外观 APPEARANCE
Time (days)
2
Manufacturer reserve the right to alter or amend the design, model and specification without prior notice
产品规格书(Product Specification)
型号(Model No.)ESP750AAH
型号(Type):ESP750AAH
单颗电池规格 Specifications of single cell

PHE450中文资料

PHE450中文资料

234In accordance with IEC E12 series.±5% standard. Other tolerances on request –55° C to +105° C +85° CThe rated voltage is decreased with 1.3% / ° C between +85° C and +105° C 55/105/56The 100 % factory test is carried out at 1.6 x U R VDC Measured at 23° C, 100 VDC 60s for U R < 500 VDC and at 500 VDC for U R ≥ 500 VDC Between terminals:C ≤ 0.33 µF: ≥ 100 000 M ΩC > 0.33 µF: ≥ 30 000 sBetween terminals and case:≥ 100 000 M ΩMaximum values at 23°CC ≤ 0.1 µF 0.1 µF < C ≤ 1.0 µFC > 1.0 µF 1 kHz 0.03 %0.03 %0.03 %10 kHz 0.04 %0.06 %–100 kHz 0.15 %––Approximately 6 nH/cm for the total length of capacitor winding and the leads.The capacitors can withstand an unlimited number of pulses with a dU/dt according to the article table. For peak to peak voltages lower than the rated voltage (U PP < U R ), the specified dU/dt can be multiplied by U R /U PP .PHE450• Double metallized film pulse capacitor, polypropylene dielectric • According to IEC 60384-17 Grade 1.1• Small sizes• Replacing PHE427, PHE428TYPICAL APPLICATIONSCONSTRUCTIONTECHNICAL DATAHigh frequency applications with high current stress, such as deflection circuits in TV-sets, protection circuits in SMPS and in electronic ballasts.Polypropylene dielectric with double metallized polyester film as electrodes.Encapsulation in self-extinguishing material meeting the requirements of UL 94V-0.Rated voltage U R , VDC Rated voltage U R , VAC Capacitance range Capacitance valuesCapacitance tolerance Categorytemperature range Rated temperature Voltage derating Climatic category T est voltagebetween terminals Insulation resistanceDissipation factor tan δInductance Pulse rise timeENVIRONMENTAL TEST DATAAccording to IEC 60384-17, Grade 1.1 and Quality tests and requirements for PulseCapacitors in the Evox Rifa Film Capacitors catalogue.p d std I max I b 7.5±0.40.65-130± 0.410.0±0.40.65-130± 0.415.0±0.40.86-130± 0.422.5±0.40.86-130± 0.427.5±0.40.86-130± 0.437.5±0.51.06-130± 0.7Three different winding constructions are used, depending on voltage and lead spacing. They are specified in the article table.2 section construction3 section construction235PHE450µF F FµF FPHE450236PHE450237PHE450238PHE450239PHE450240PHE450241PHE450242PHE450243PHE450244PHE450245。

Series 450 编号BA01235O的Compact Thermometer产品说明书

Series 450 编号BA01235O的Compact Thermometer产品说明书

Operating manual Series 450BA01235O/09/en/01.13 71220279Compact thermometer2Table of contents1 Safety instructions (3)2 Installation (4)3 Wiring overview (7)4 Commissioning (7)5 Operation (8)6 Accessories (8)7 Troubleshooting (9)8 Return (10)1 Safety instructionsDesignated use❑The device is a compact thermometer for the acquisition and optionalconversion of temperature input signals for industrial temperaturemeasurement.❑The manufacturer is not liable for damage caused by improper or non-designated use.Installation, commissioning, operation ❑The device must only be installed, connected and commissioned by qualified and authorized expert staff (e.g. electrical technicians) strictly adhering to the instructions contained in this manual, the applicablenorms, legal regulations and certificates (depending on the application).❑These experts must have read and understood this manual and follow the instructions it contains.❑Damaged devices must not be put into operation and they must be labeled as defective.3Operational safety❑The device is safely built and tested according to state-of-the-arttechnology and has left the factory in perfect condition as regards technicalsafety. The applicable regulations have been taken into account.❑The device must only be powered by a power supply unit with a limitedenergy electric circuit in accordance with IEC 61010-1: "SELV or Class 2circuit".❑Due to its design, the device is not repairable. When later disposing of thedevice, please observe the local regulations.2 InstallationInstallation instructions ❑Permitted ambient temperature range: -40 to 85 °C (-40 to 185 °F)❑Process temperature limits:– without extension neck: -50 to 150 °C (-58 to 302 °F)– with extension neck: -50 to 200 °C (-58 to 392 °F)– without transmitter: -50 to 200 °C (-58 to 392 °F)Restrictions (process connection for general applications) subject to the ambient temperature (recommended guideline values):Max. ambient temperature Max. process temperature Max. process temperaturewith extension neck•up to 25 °C (77 °F)•up to 40 °C (104 °F)•up to 60 °C (140 °F)•up to 85 °C (185 °F)•150 °C (302 °F)•135 °C (275 °F)•120 °C (248 °F)•100 °C (212 °F)•200°C(392°F)•180°C(365°F)•160°C(320°F)•133°C(271°F)4❑Process pressure limits:depending on the process connection, up to max. 100 bar (1450 PSI) at20 °C (68 °F).Pos. A: On angle bracketsPos. B: In smaller pipes, inclinedPos. C: Perpendicular to the direction of flowL = Insertion length56Minimum insertion length L min = 40 mm (1.6 in)Installation1.Seal the process connection (for general applications) with Teflon tape before you screw in the device.2.Ensure that the hygienic process connections and the connection adapters can withstand the maximum process pressure.3.Install the device before the process application is started.4.Fit the M12 plug onto the device and connect the power supply accordingly (see chap.3).Do not tighten the M12 plug too much, in order to prevent damage to the device.3 Wiring overviewPin assignment of the 4-wire M12 plug for output signal and power supply.4 CommissioningOnce the supply voltage is applied, the device is in operation.75 OperationThe configuration of the compact thermometer is performed using the PCconfiguration software, which is available in the configuration kit as anaccessory.Settable parametersStandard settings•Measuring unit (°C/°F)•Measuring range limits-50 to 150 °C (-58 to 302 °F) without extension neck-50 to 200 °C (-58 to 392 °F) with extension neckAdvanced settings•Fault condition reaction•Output (analog standard/inverse)•Filter (0 ... 8 s)•Offset (-9.9 to +9.9 K)•Measurement point identification/TagService functions•Simulation (on/off)Detailed information about configuration using the PC configuration softwarecan be found in the online documentation of the PC software.6 AccessoriesConfiguration kit (PC configuration software and interface cable USB) for thecompact thermometer. Please contact your supplier when ordering.87 TroubleshootingAlways start troubleshooting with the checklists below if faults occur after start up or during operation. This takes you directly (via various queries) to the cause of the problem and the appropriate remedial measures.Due to its design, the device cannot be repaired. However, it is possible to send the device in for examination. See the information in the "Return" section.Problem Possible cause RemedyDevice is not responding Supply voltage does notmatch that specified on thenameplate.Apply correct voltage.Broken cable, or connectingcables are not in contact withthe terminals.Check cable and contactingof the cables and correct ifnecessary.Measured value is incorrect/inaccurate Incorrect sensor orientation.Install the sensor correctly. Device programming isincorrect (scaling).Change scaling.Offset incorrectly set.Check offset.Failure current(≤ 3.6 mA or ≥ 21 mA)Device programming isincorrect (scaling).Change scaling.Faulty sensor.Replace device. Electronics unit is defective.98 ReturnThe following procedures must be carried out before a device is returned tothe manufacturer:❑Remove all fluid residues. This is particularly important if the fluid ishazardous to health, e.g. flammable, toxic, caustic, carcinogenic, etc.Do not return a measuring device if you are not absolutely certain that alltraces of hazardous substances have been removed, e.g. substances whichhave penetrated crevices or diffused through plastic.1011BA01235O/09/EN/01.13 - 71220279 - FM10。

丹非尔福电子过压阀值5-400 商品说明册说明书

丹非尔福电子过压阀值5-400 商品说明册说明书

DKRCC.PD.VD1.C6.02 / 520H8021Data sheetElectric expansion valve Type ETS 12.5 - ETS 400MAKING MODERN LIVING POSSIBLE@ Danfoss A/S (AC-MCI / sw), 2015-08Features• Precise positioning for optimal control of liquid injection.• Wide range for all common refrigerants R410A, R407C, R404A, R507, R134a, R22, R1234ze(special valves for R744 (CO 2) are available).• ETS 12.5, ETS25, ETS 50 and ETS100 provides working pressure of 45.5 bar / 660 psig and ETS 250, ETS 400 provides 34 bar / 493 psig.• Balanced design (ETS 50 – ETS 400) providing bi-flow operation as well as solenoid tight shut-off function in both flow directions.• ETS 50 and ETS 100 feature improved process and productivity due to waterless brazing i.e soldering without wet cloth for cooling.• ETS 50 – ETS 400 are all designed with built-in sight glass with moisture indicator.• Internal and external corrosion resistant design.• Low power consumption.• Cable and connector assemblies as accessories.• EKC 316A, EKC 312 and EKD316 are examples of Danfoss controllers with drivers matching the ETS needs.• For manual operation and service of ETS valves an AST-g service driver is available.ETS is a series of electric expansion valves for precise liquid injection in evaporators for air conditioning and refrigeration applications.The valve piston and linear positioning design is fully balanced, providing bi-flow feature as well as solenoid tight shut-off function in both flow directions.The valve design uses bi-polar drive providing very precise flow regulation.ETS valves are compatible with electronic control solutions from Danfoss and other manufacturers.Data sheetElectric expansion valve, type ETS2DKRCC.PD.VD1.C6.02 / 520H8021 @ Danfoss A/S (AC-MCI / sw), 2015-08Technical dataElectrical dataNOTE:Data sheet Electric expansion valve, type ETS3 @ Danfoss A/S (AC-MCI / sw), 2015-08 DKRCC.PD.VD1.C5.02 / 520H7857Designrefers to the normal flow.1. M12 connection2. Glass seal3. AST motor housing4. Stepper motor5. Bearing6. Spindle7. Cone and lead nut8. Valve seat1. M12 connector2. Glass seal3. AST motor housing4. Stepper motor5. Bearing6. Spindle7. Top Nut8. Valve piston9. Sight glass with indicator10. Valve seat11. Valve cone1. M12 connector2. Glass seal3. AST motor housing4. Stepper motor5. Bearing6. Spindle7. Top Nut8. Valve piston9. Valve seat10.Valve coneData sheetElectric expansion valve, type ETS4DKRCC.PD.VD1.C6.02 / 520H8021 @ Danfoss A/S (AC-MCI / sw), 2015-08Stepper motorswitch sequenceElectrical wiringIf the controller driving the ETS valve is from another manufacturer than Danfoss or a custom design, the following points must be considered in order to overcome potential step loss.a. To ensure total closing of the valve, thecontroller should have a function to overdrive the valve in the closing direction. It isrecommended to overdrive ten percent of the full step range at appropriate intervals.b. The amount of lost steps may increase as a function of the amount of changes of the opening degree. Such designed controller should be able to compensate the lost steps after a defined number of changes in openingdegree.At power failure the ETS valve will remain in the opening position it has at the moment of power failure, unless a safety device in the form of a battery backup is installed.ETS 50, ETS 100, ETS 250 and ETS 400 are equipped with sight glass with moistureindicator. The physical position of the piston in the valve can be checked through the sight glass. It also helps to determine the flow direction of the refrigerant in the system (ETS 50 and ETS 100).Insufficient sub cooling can produce flash gas which is visible through the sight glass. The moisture indicator in the sight glass indicates dry or wet state of the refrigerant by changing its colour.Sight glass and indicatorData sheetElectric expansion valve, type ETS5@ Danfoss A/S (AC-MCI / sw), 2015-08 DKRCC.PD.VD1.C5.02 / 520H7857Valve applicationValve operationThe ETS valves operate modulating byelectronically controlled activation of the AST stepper motor. The motor is a type 2-phase bi-polar, which stays in position, unless power pulses from a driver initiate the two discrete sets of motor stator windings for rotation in eitherdirections.The direction of the rotation of the spindledepends on the phase relationship of the power pulses. This is decisive for the travel of the piston. The motor is operating the spindle, whoserotating movements are transformed into linear motion by the transmission in the cage assembly.The AST motor housing has a glass sealed M12connection as standard, which can be connected with customized cable and plug/socket combinations.The piston design inside the ETS valve is pressure balanced, giving identical bi-flow performance capabilities and nearby identical maximum capacities.Closing the valve by overdriving, ensures that the reference number in steps is always correct.Operating the ETS series requires a controller with either 12 V DC voltage drive (5.5 W) or using chopper current drive (100 mA RMS).Danfoss EKC 316A, EKC 312 and EKD 316 are examples of qualified current controllers.there will be limitations in cable length between valve actuator and driver.Both the actual cable length, the level of EMC emission on the location and driver circuit has an impact on the actual distortion of the current to the actuator motor.For the Danfoss controllers the rule of thumb is maximum 5 m / 15 feet for EKC 316A and EKC 312 and 50 m / 150 feet for EKD 316.In order to increase max. cable lengthconsiderably, install a 10 mH filter type Danfoss AKA 211 on the four power terminals.Please contact Danfoss for further information how and when to apply this countermeasure in cases with questionable cable length.Data sheetElectric expansion valve, type ETS6DKRCC.PD.VD1.C6.02 / 520H8021 @ Danfoss A/S (AC-MCI / sw), 2015-08ETS 12.5, ETS 25Valve incl. actuatorOrderingETS 50, ETS 100Valve incl. actuatorglass1) The Rated capacity is based on: Evaporating temperature t e : 5 °C (40 °F) Liquid temperature t l : 28 °C (82 °F) Condensing temperature t c : 32 °C (90 °F)Full stroke opening in normal flow directionETS 250, ETS 400Valve incl. actuatorETS for R744 ApplicationsETS 250 and ETS 400 have integrated sight glassETS 50 and ETS 100 have integrated sight glassETS for R744 can be used for expansion as well as gas bypass.ETS for R744 Applications (PS/MWP = 45.5 bar / 660 psig)For capacities, please contact Danfoss.BData sheetElectric expansion valve, type ETS7@ Danfoss A/S (AC-MCI / sw), 2015-08 DKRCC.PD.VD1.C5.02 / 520H7857 Accessories:M12 Female Connector CableData sheetElectric expansion valve, type ETS8DKRCC.PD.VD1.C6.02 / 520H8021 @ Danfoss A/S (AC-MCI / sw), 2015-08For optimum performance, it is important to correct the evaporator capacity. Selection is also dependent on an acceptable pressure drop across the valve. The evaporator capacity must be corrected if sub cooling deviates from 4K / 7.2 °F. In order to select the correct size of ETS you will need the following information:• Refrigerant: R410A, R407C, R404A, R507, R134a, R22, R1234ze• Evaporator capacity Q e in [kW] or [TR]• Evaporating temperature t e in [°C] or [°F]• Condensing temperature t c in [°C] or [°F]• Max. acceptable pressure drop in the ETS valve in [bar] or [psi] Δp • Sub cooling Δt sub • Connection size ExampleWhen selecting the valve it may be necessary to apply a correction factor to the actual evaporator capacity. This correction factor is required when system conditions are different from tableconditions. Selection also depends on having an acceptable pressure drop across the valve. The following example illustrates correct selection of the valve.• Refrigerant: R410A• Evaporator capacity: Q e = 500 kW / 143 TR • Condensing temperature: t c = 25 °C / 77 °F • Condensing pressure: p c = 23 bar / 330 psig • Evaporating temperature: t e = +10 °C / 50 °F • Evaporating pressure: p e = 9.8 bar / 142 psig • Liquid Line Loss: p l = 0.5 bar (estimate)•Max. Pressure drop in the valve:Δp = p c - p l - p e = 23 - 0.5 - 9.8 = 12.7 bar / 184 psi • Connection size: 11/8 × 11/8 in.Valve sizingValve selectionNow select the appropriate capacity table, R410A, and choose the column for an evaporating temperature of t e = 10 °C / 50 °F.Using the corrected evaporator capacity, select a valve that provides an equivalent or greater capacity at an acceptable pressure drop across the valve of 12.7 bar / 184 psi.ETS 100 delivers 503.8 kW / 143 TR at 14 bar which is slightly higher than 12.7 bar / 184 psi pressure drop across the valve. Based on the required connection size of 11/8 in., the ETS 100 is the proper selection for this example.Step 3Step 4Determine the correction factor for sub cooling Δt sub .From the correction factors table (see below) a sub cooling of 15K / 27 °F, R410A corresponds to a factor of 1.15.Corrected evaporator capacity isQ e (Corrected) = 500 kW/1.15 = 435 kW (124 TR)Step 1Step 2ETS 100, 11/8 x 11/8 in. connection size: Single pack code no. 034G0507./businessareas/refrigerationandairconditioning/ product+selection+tools+details/coolselector.htmData sheet Electric expansion valve, type ETS9@ Danfoss A/S (AC-MCI / sw), 2015-08 DKRCC.PD.VD1.C5.02 / 520H7857 Correction for subcooling ∆tsub Note:The evaporator capacities used must be corrected if subcooling deviates from 4 K / 7.2 °F.The corrected capacity can be obtained bydividing the required evaporator capacity by the correction factor. Selections can then be madefrom the tables below.Rated Capacity [kW]Data sheetElectric expansion valve, type ETS10DKRCC.PD.VD1.C6.02 / 520H8021 @ Danfoss A/S (AC-MCI / sw), 2015-08Rated Capacity [kW]The capacities stated in the tables are for the normal flow direction. For ETS 50 and 100 specifically, the capacity in reverse flow direction varies between 90% and 125% of the capacity in normal flow direction.Rated Capacity [kW]Rated Capacity [TR] (TR = ton of refrigeration)Rated Capacity [TR](TR = ton of refrigeration)The capacities stated in the tables are for the normal flow direction. For ETS 50 and 100 specifically, the capacity in reverse flow direction varies between 90% and 125% of the capacity in normal flow direction.Rated Capacity [TR] (TR = ton of refrigeration)CapacityNormal flow directionCapacity based on: R407C T e = 5 °C / 41 °F T c = 32 °C / 89.6 °F T l = 28 °C / 82.4 °FDimensions and weights forETS 50 and ETS 100Dimensions and weights forETS 12.5 and ETS 25Dimensions and weights for ArrayETS 250 and ETS 400For further information please contact DanfossSpare partsETS 25B, ETS 50, ETS 100, ETS 250 and ETS 400 (long spindle)Gasket for all typesRelated Danfoss Products。

Leica Aperio GT 450 使用者指南说明书

Leica Aperio GT 450 使用者指南说明书

Aperio GT 450使用者指南MAN-0391-zh-CHT,修訂版 D | 2022 年 3 月Aperio GT 450 使用者指南本手冊適用於 Aperio GT 450 控制器、Aperio GT 450 控制台和 Aperio GT 450 SAM 1.1 版本及更高版本版權聲明Ì© 2019-2022 Leica Biosystems Imaging, Inc. 版權所有,保留所有權利。

LEICA 和 Leica 標誌是 Leica Microsystems IR GmbH 的註冊商標。

Aperio、GT 和 GT 450 是 Leica Biosystems Imaging, Inc. 在美國和其他國家/地區的商標。

其他標誌、產品和/或公司名稱可能為其各自所有人之商標。

Ì本產品受註冊專利保障。

如需專利列表,請聯絡 Leica Biosystems。

客戶資源Ì如需 Leica Biosystems Aperio 產品及服務的最新資訊,請造訪 /Aperio。

僅供研究使用。

不得用於診斷程序。

23GT450, 23GT450SAM2Aperio GT 450 使用者指南,修訂版 D © Leica Biosystems Imaging, Inc. 2022內容注意 (7)修訂記錄 (7)預期用途 (7)注意及警告事項 (7)符號 (8)客戶服務部聯絡資訊 (10)1 簡介 (12)資源 (13)警告 (13)電磁警告 (13)儀器警告 (14)元件和零件更換警告 (14)合規性規格 (15)安裝 (15)Aperio GT 450 的處置 (15)掃描器安全性指示 (16)2 Aperio GT 450 概觀 (18)掃描器概觀 (18)將掃描器開機和關機 (19)觸控螢幕介面概觀 (20)主畫面 (20)幫助影片和指南 (22)特點 (22)連續載入工作流程 (22)掃描放大倍率 (22)自動影像品質檢查 (22)支援的影像類型 (22)支援的載玻片類型 (23)蓋玻片 (23)支援的載玻片架 (23)Aperio GT 450 使用者指南,修訂版 D © Leica Biosystems Imaging, Inc. 20223內容載玻片容量 (23)支援的條碼 (23)選配的 Aperio 檢視工作站 (23)Aperio 數位載玻片檢視 (23)3 載玻片準備 (24)組織準備 (24)染色 (24)載玻片準備 (24)組織放置 (25)修正載玻片準備錯誤 (25)蓋玻片 (25)標籤 (26)條碼 (26)4 掃描載玻片 (27)掃描概念 (27)掃描工作流程 (27)圓盤傳輸帶旋轉 (28)登入和登出掃描器 (28)將載玻片載入玻片架 (29)將玻片架載入圓盤傳輸帶 (30)優先掃描 (32)將玻片架旋轉至玻片架載入區域 (33)從圓盤傳輸帶卸載玻片架 (34)檢查掃描狀態 (35)檢查玻片架狀態 (36)目前掃描發生玻片架錯誤 (36)檢視玻片架中的載玻片狀態 (37)檢視已掃描載玻片的巨觀影像 (38)檢視玻片架掃描順序 (38)玻片架警告 (39)為整個玻片架掃描整張載玻片 (41)組織學技術人員和病理學家的影像品質控制 (42)掃描統計資料 (42)5 維護 (43)維護時間表 (43)序號和韌體版本 (44)關閉掃描器 (44)開啟掃描器罩蓋以接觸內部元件 (45)4Aperio GT 450 使用者指南,修訂版 D © Leica Biosystems Imaging, Inc. 2022內容建議的每日維護 (46)重新啟動掃描器 (46)六個月維護 (47)清潔物鏡與 Koehler (47)需要的材料 (47)清潔載物台載玻片托盤 (50)清潔圓盤傳輸帶 (51)清潔風扇濾網 (52)清潔載玻片架 (54)清潔掃描器罩蓋 (54)清潔觸控螢幕 (55)內部維護後重新啟動掃描器 (55)搬移或移動 Aperio GT 450 (56)長期封存 (56)6 疑難排解 (57)個人保護設備 (57)圓盤傳輸帶上閃爍紅燈 (57)如何使用疑難排解步驟 (57)發生錯誤後安全重啟 (58)錯誤碼與解決方案 (60)1000:內部錯誤 (60)1001:掃描器無法初始化 (62)1002:圓盤傳輸帶無法旋轉 (64)1003:圓盤傳輸帶無法旋轉。

Omega 450 系列数字温度指示器用户手册说明书

Omega 450 系列数字温度指示器用户手册说明书

e-mail:**************450 SERIESDigital ThermometersBenelux:Postbus 8034, 1180 LA Amstelveen The NetherlandsTel: +31 (0)20 3472121 FAX: +31 (0)20 6434643Toll Free in Benelux: 0800 0993344e-mail:*****************Czech Republic:Frystatska 184, 733 01 Karvina ´, Czech Republic Tel: +420 (0)59 6311899 FAX: +420 (0)59 6311114Toll Free: 0800-1-66342 e-mail:*****************France:11, rue Jacques Cartier 78280 Guyancourt, FranceT el: +33 (0)1 61 37 2900 FAX: +33 (0)1 30 57 5427Toll Free in France: 0800 466 342e-mail:**************Servicing Europe:Germany/Austria:Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Tel: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29TollFreeinGermany************e-mail:*************United Kingdom: ISO 9002 Certified One Omega DriveRiver Bend Technology Centre Northbank, Irlam, Manchester M44 5BD United Kingdom Tel: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622Toll Free in United Kingdom:0800-488-488 e-mail:**************.ukIt is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply.OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.The information contained in this document is believed to be correct, but OMEGA Engineering,Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.RETURN REQUESTS/INQUIRIESDirect all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETU RNING ANY PRODU CT(S) TO OMEGA, PU RCHASER MU ST OBTAIN AN AU THORIZED RETU RN (AR) NU MBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS).The assigned AR number should then be marked on the outside of the return package and on any correspondence.The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR WARRANTY RETURNS, please have the following informationavailable BEFORE contacting OMEGA:1.Purchase Order number under which the product was PURCHASED,2.Model and serial number of the product under warranty, and3.Repair instructions and/or specific problems relative to the product.FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE con-tacting OMEGA:1. Purchase Order number to cover the COST of the repair,2.Model and serial number of the product, and3.Repair instructions and/or specific problems relative to the product.OMEGA’s policy is to make running changes, not model changes, whenever an improve-ment is possible. This affords our customers the latest in technology and engineering.OMEGA is a registered trademark of OMEGA ENGINEERING, INC.© Copyright 2003 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.Section 1: Description1.1 General Description (2)1.2 Physical Description (3)1.3 Unpacking (3)1.4 Specification (4)Section 2: Operation2.1 Principles of Operation (7)2.2 Power (8)2.3 Operation (10)2.4 Maintenance (13)Section 3: Calibration3.1 Calibration (14)1.1 General DescriptionYour hand-held, battery operated digital temperature indicator is configured for compatibility with one of five temperature transducers, J,K,E,T RTD and Thermister.Each of the configurations linearizes the analog output from the transducer to produce a stable and accurate digital temperature display. Plug-in type input connectors are used for the transducer input to provide quick connect and disconnect capability. The indicator functions are controlled by the key-board. The liquid crystal display exhibits the valueof the measurement, degrees Fahrenheit or Celsius, and the low battery voltage indication.The use of advanced digital design techniquesgive the indicator extremely accurate readings and exceptionally long battery life.21.2 Physical DescriptionThe indicator measures 45 mm (1.8 inches) in Height, 85 mm (3.3 inches) in width, and 145 mm (5.7 inches) in length. Weight is 230 grams (8.0 ounces). The case is constructed of high impact plastic.1.3 UnpackingThe indicator is supplied with the battery installed.A quick electrical test should be performed to verify that the indicator is operative. See 2.3 in Section 2 for operating instructions.Contact our Instrument Repair Department immediately if any problems are observed after checking out operation of the unit.3SpecificationsDisplay:Liquid crystal display, 7.6 mm (0.3 in.) digit HeightOperating temperature:0 to 50°C (32 to 122°F) 0 to 75% RelativeHumidityStorage Temperature:-20 to 70°C (-4 to 158°F)Battery:NEDA 1604, 9 VoltBattery Life:Thermocouple-2000 hours minimumPlatinum RTD-500 hours minimumThermistor- 1200 hours minimum NMRR:50 dB @ 50±1 Hz, 0.1° range35 dB @ 50±1 Hz or 60±1Hz, 1° range CMRR:140 dB @ 50±1 Hz, 0.1° range120 dB @ 50±1 Hz or 60±1Hz, 1° range4Maximum Common Mode Voltage:1000VAC(RMS), ±2000V PeakAccuracy at 22°C (72°F)1° range:±0.8°C±0.1% rdg±1.5°F±0.1% rdg0.1° range:±0.25°C±0.1% rdg±.45°F±0.1% rdg Stability with time:90 days:add ±0.05% rdg.1 year:add ± 0.1% rdg. Stability with temperature:Thermocouple:zero: ±0.03°C/°Cspan: ±0.02% rdg/°C (max)reference junction tracking ±1.0°C (±1.8°F)from 5°C to 45°C (41°F to 113°F)Platinum RTD: ±0.02°C, ±0.01% rdg/°CThermistor:positive- ±0.02°C/°Cnegative-±0.04°C/°C5450 Range Table62.1 Principles of OperationThe temperature indicator uses two ICs to digitize and display the analog input signal.One IC performs the conversion of the analog input to the digital equivalent via 24 bit delta-sigma analog to digital converter. Battery voltage is also monitored by this IC and a thermistor supplies the reference junction correction signal. The other IC receives input from the analogto digital converter, linearizes and drives the LCD display. Front panel buttons are also monitored.72.2 PowerWhen battery voltage reaches about 6 volts, the display will exhibit a flashing: “LOW BAT” indication.A minimum of 20 hours of operation time remains upon initial appearance of the “LOW BAT” indication. When the battery voltage drops below 5 volts, an overload indications of three columns of dashes will appear on the display in addition to the flashing “LOW BAT” symbol.The indicator uses a NEDA 1604 (or equivalent) 9 Volt battery. The battery will provide a minimum of 2000 hours of continuous thermocouple operation, 500 hours of RTD operation, or 1200 hours of thermistor operation. To replace the battery, follow these steps.Note: The indicator must be OFF whenReplacing the battery.Step 1: Place the indicator face down on a flat surface and remove the four screws located in8the recesses or each corner of the case bottom. Step 2: Carefully pull the case halves straight apart so as not to damage the internal connectors. Step 3. Install the new battery. Close the case and reinstall the four screws.92.3 OperationStep 1: Insert temperature sensor plug into the indicator input jack. Failure to insert a probe results in a overload condition of three columns of dashes showing on the display.Step 2: Turn the indicator ON by pressing the °For °C key. The display can be switched to read the temperature in degrees Celsius or Fahrenheit without affecting calibration.Step 3: Select the display range of 1° (wide range, low resolution) or 0.1° (narrow range, high resolution) with the 1°/0.1° key.Note: The thermistor unit hasa fixed resolution of 0.1°.Step 4: By pressing and holding the HOLD key,The last reading will be displayed as long as the hold key is depressed. After the hold key is released, the indicator will revert to its normal display mode.10Step 5: Observe and or record the temperature value.Step 6: Turn instrument off by pressing the OFF key.11BatteryVoltageTo HoldDisplaykey toturn OFFtemperature scaleOperation Features122.4 MaintenanceNormal maintenance of the indicator consists of occasional cleaning with a soft, damp cloth, replacement of the battery as required, and calibration as outlined in Section 3.133.1 CalibrationUnits with serial numbers beginning with the letter N use the calibration procedure outlined below. Older units do not display version numbers and use the calibration procedureson page 19 .The calibration procedure should be performedby a qualified instrumentation service technician. The indicator may be brought to any instrumentation calibration and repair laboratory (metrology lab) for the service (this manual should accompany the instrument). This procedure should be done at least once a year to guarantee continued performance within the specification.The instrument should be calibrated at an ambient temperature of 22° C with a thermocouple simulator14with a minimum accuracy of ±0.1 degree Fahrenheit or ±0.2 degree Centigrade.Step 1. Ensure the unit is turned off. Connect the output of the thermocouple simulator to the input of the indicator using the appropriate thermocouple wire. Set the simulator output to 0°CStep 2. Locate the calibration switch on the back of the case labeled “Zero”. Remove the black button. Using a small screw drive or flat end of the trimmer pot, press the cal switch once. The display should read version and then switch to ambient temperature; press the switch one more time. The display should indicate .0.0 °CStep 3. Press the switch one more time, the display should read max calibration temperature (for K type: 13.2.0, for J type: 9.6.0, for T type: 3.5.0, and for E type: 9.5.0) Now, set the simulator output to display temperature as show in table below.15NOTE: If you want to cancel the calibration mode press OFF button in front of the unit.For T/C type K set simulator @ 1320 °CJ set simulator @ 960 °CT set simulator @ 350 °CE set simulator @ 950 °CPress the switch one more time and wait for a few seconds until display switches to 0.0 set simulator to 0°C. Press switch one more time. Unit should shut-off.Step 4. Now, turn the unit on from front panel. Make sure the unit in degree C mode. Verify that the unit is within specification throughout its range. Step 5. If unit does not meet specification as 0°C then repeat calibration procedure,Instead of setting simulator as 0°C, set it at the temperature indicated by the unit in measurement mode as 0°C. For example in measure mode, unit may display .2°C with simulator as 0°C. During16calibration procedure, set simulator at .2°C instead of 0 °C. Repeat the calibration procedure again. Step 6. Verify calibration once finished.17Ra - Full Scale Adj. Rb Zero Adj.Rc +Full Scale Adj.18Calibration- Thermocouple Type K, J and Tand EEquipment List• 4 ½digit voltmeter• Voltage Calibrator:Resolution, 1uV; accuracy ±0.01% (±2uV)• Ice Bath, 0.00 °C ± 0.05°C• Jumper lead terminated in mini-clipsFor optimum results, the calibration should be performed with an ambient temperature from 20°24°C (68° to 75°F). Refer to the figure on the previous page for the locations of all testpoints and adjustments.a. Turn the indicator ON by pressing the °C key.b. For types K, J, E and T units only, switchthe indicator to the 0.1° range.19c. Remove the bottom case of the indicator.d. Adjust the voltage calibrator for an output of0.000mV and connect the minus lead from thecalibrator to “GND” and the positive leadfrom the calibrator to “;+IN”, on the indicatorprinted circuit board.e. Disable the reference junction by jumperingtogether the “REF J” and “GND” testpoints,using a jumper lead terminated in mini-clips.f. Adjust Rb for an indicator display of 0.0°C.g. Connect the DVM LO lead to “GND”, on theindicator printed circuit board.h. Using HI lead of DVM, measure voltageat the “-1.23V” testpoint: disregardingpolarity indication, record the voltage.i. Move the DVM HI lead to the “3.7V”testpoint and record the voltage (disregard20polrity).j. The voltage measured at the “3.7V” test-point should be 3.007 times larger thanthe voltage measured at the “-1.23V” test-point. Adjust Rc (which varies the +3.7Vline to attain the proper ratio.k. Switch the indicator to the 1° range.l. Adjust the voltage calibrator for an output of +53.782mV for type K; +57.942mV for type J;+75.983mV for type E; +18.824mV for type T; m. Adjust Ra for an indicator display of +995°C for type E, or 1000°C for type J, or +1340°Cfor type K, or +367°C for type T.n. Reassemble the indicator.o. Perform the zero calibration.21Calibration- Thermistor TypeEquipment List• 4 ½digit voltmeter• Precision decade box:Resolution, 0.01 ohm ; accuracy ±0.02%• Ice Bath, 0.00 °C ± 0.05°C• Electro Scientific Industries DB-62 orequivalenta. Turn the indicator ON by pressing the °C key.b. Remove the bottom case of the indicator.c. Connect a precision resistance box to theterminals on the phone input jack; set theresistance box to 7,280 ohms.d.Connect the DVM LO lead to “GND”, on theindicator printed circuit board.ing HI lead of DVM, measure voltage22at the “-1.23V” testpoint: disregardingpolarity indication, record the voltage.f.Move the DVM HI lead to the “3.7V”testpoint and record the voltage (disregardpolarity).g.The voltage measured at the “3.7V” test-point should be 3.007 times larger thanthe voltage measured at the “-1.23V” test-point. Adjust Rc (which varies the +3.7Vline to attain the proper ratio.h.Adjust Rb for an indicator display of 0.2°C.i.Set the resistance box to 148.4 ohms.j.Adjust Ra for an indicator display of +101.0°C. k.Reassemble the indicator.l.Perform the zero calibration23Calibration- Platinum RTDEquipment List• 4 ½digit voltmeter• Precision decade box:• Resolution, 0.01 ohm ; accuracy ±0.02%• Ice Bath, 0.00 °C ± 0.05°C• Electro Scientific Industries DB-62 orequivalenta. Turn the indicator ON by pressing the °C key.b. Remove the bottom case of the indicator.c. Connect a precision resistance box to theterminals on the RTD input jack and set theresistance box to 100.04 ohms.ing HI lead of DVM, measure voltageat the “-1.23V” testpoint: disregardingpolarity indication, record the voltage.24e.Move the DVM HI lead to the “3.7V”testpoint and record the voltage (disregardpolrity).f.The voltage measured at the “3.7V” test-point should be 3.007 times larger thanthe voltage measured at the “-1.23V” test-point. Adjust Rc (which varies the +3.7Vline to attain the proper ratio.g.Adjust Rb for an indicator display of 32.2°F.h.Adjust Ra for an indicator display of +196.0°C.i.Reassemble the indicator.Perform the zero calibration25Zero Calibrationa. Turn the indicator on by pressing the °Ckey.b. Set the indicator to the 0.1° range.c. Connect the ice bath probe to the indicatorInput jack.d. Place the probe in a stable ice bath (0.00C±0.05°C and adjust the ZERO pot (Rb)located beneath the plug on the rear casefor an indicator display of 0.0°C.e. Replace the rubber plug.Calibration is complete.26WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediate-ly upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER W ARRANTIES OR REPRESENTATIONS OF ANY KIND W HATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY W ARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.TEMPERATUREⅪߜThermocouple, RTD & Thermistor Probes, Connectors, Panels &AssembliesⅪߜWire: Thermocouple, RTD &ThermistorⅪߜCalibrators & Ice Point ReferencesⅪߜRecorders, Controllers & Process Monitors ⅪߜInfrared Pyrometers PRESSURE, STRAINAND FORCEⅪߜTransducers & Strain GagesⅪߜLoad Cells & Pressure GagesⅪߜDisplacement TransducersⅪߜInstrumentation & Accessories FLOW/LEVELⅪߜRotameters, Gas Mass Flowmeters & Flow ComputersⅪߜAir Velocity IndicatorsⅪߜTurbine/Paddlewheel SystemsⅪߜTotalizers & Batch ControllerspH/CONDUCTIVITYⅪߜpH Electrodes, Testers & Accessories ⅪߜBenchtop/Laboratory MetersⅪߜControllers, Calibrators, Simulators & PumpsⅪߜIndustrial pH & Conductivity Equipment DATA ACQUISITIONⅪߜData Acquisition &Engineering SoftwareⅪߜCommunications-BasedAcquisition SystemsⅪߜPlug-in Cards for Apple, IBM& CompatiblesⅪߜDatalogging SystemsⅪߜRecorders, Printers & Plotters HEATERSⅪߜHeating CableⅪߜCartridge & Strip HeatersⅪߜImmersion & Band HeatersⅪߜFlexible HeatersⅪߜLaboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL ⅪߜMetering & Control Instrumentation ⅪߜRefractometersⅪߜPumps & TubingⅪߜAir, Soil & Water MonitorsⅪߜIndustrial Water & WastewaterTreatmentⅪߜpH, Conductivity & DissolvedOxygen InstrumentsM0099/0603Where Do I Find Everything I Need for Process Measurement and Control?OMEGA…Of Course!Shop online at 。

SB450钢板规格明细,SB450日标容器钢板切割,SB450对应美标

SB450钢板规格明细,SB450日标容器钢板切割,SB450对应美标

SB450钢板规格明细,SB450日标容器板切割,SB450对应美标SB450是日标容器板,其中的“SB”表示日标容器板,“450”则指该钢板的屈服强度不低于450MPa。

执行标准为:JISG3103。

SB450对应美标A515 Grade 65/A515M Grade 450SB450钢板:#舞阳孙凡#試験片の熱処理は,鋼板から採取した供試材の状態で行う。

熱処理は,4.2.1.3 の熱処理の指示による。

試験片は,熱処理後の供試材から探取する。

SB450钢板的厚度方向性能要求为Z15、Z25、Z35,有牌号SB450Z15、SB450Z25、SB450Z35。

SB450钢板钢板化学成分说明:SB450钢板碳含量C:0.31SB450钢板硅含量Si:0.15-0.40SB450钢板锰含量Mn:≤1.20SB450钢板磷含量P:≤0.020SB450钢板硫含量S:≤0.020SB450钢板用途:SB450钢板不仅有非常好的强度而且还具有一定的韧性、耐磨性、抗疲劳性与焊接和易加工性能。

广泛应用于石油、化工、电站、锅炉等行业,锅炉、压力容器制造、反应器、换热器、分离器、球罐、油气罐、液化气罐等。

SB450钢板规格明细:SB450 10*2500*12000SB450 12*2500*12000SB450 15*2500*12000SB450 18*2500*12000SB450 20*2500*12000SB450 30*2500*12000SB450 40*2500*12000SB450钢板切割,SB450钢板数控切割,SB450钢板等离子切割,SB450钢板激光切割船舶及海洋工程用结构钢工程机械用高强结构钢管线用钢桥梁结构用钢锅炉及压力容器用钢水电用钢风电用钢。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

234
In accordance with IEC E12 series.
±5% standard. Other tolerances on request –55° C to +105° C +85° C
The rated voltage is decreased with 1.3% / ° C between +85° C and +105° C 55/105/56
The 100 % factory test is carried out at 1.6 x U R VDC Measured at 23° C, 100 VDC 60s for U R < 500 VDC and at 500 VDC for U R ≥ 500 VDC Between terminals:
C ≤ 0.33 µF: ≥ 100 000 M ΩC > 0.33 µF: ≥ 30 000 s
Between terminals and case:≥ 100 000 M Ω
Maximum values at 23°C
C ≤ 0.1 µF 0.1 µF < C ≤ 1.0 µF
C > 1.0 µF 1 kHz 0.03 %0.03 %0.03 %10 kHz 0.04 %0.06 %–100 kHz 0.15 %––
Approximately 6 nH/cm for the total length of capacitor winding and the leads.
The capacitors can withstand an unlimited number of pulses with a dU/dt according to the article table. For peak to peak voltages lower than the rated voltage (U PP < U R ), the specified dU/dt can be multiplied by U R /U PP .
PHE450
• Double metallized film pulse capacitor, polypropylene dielectric • According to IEC 60384-17 Grade 1.1• Small sizes
• Replacing PHE427, PHE428
TYPICAL APPLICATIONS
CONSTRUCTION
TECHNICAL DATA
High frequency applications with high current stress, such as deflection circuits in TV-sets, protection circuits in SMPS and in electronic ballasts.
Polypropylene dielectric with double metallized polyester film as electrodes.Encapsulation in self-extinguishing material meeting the requirements of UL 94V-0.
Rated voltage U R , VDC Rated voltage U R , VAC Capacitance range Capacitance values
Capacitance tolerance Category
temperature range Rated temperature Voltage derating Climatic category T est voltage
between terminals Insulation resistance
Dissipation factor tan δInductance Pulse rise time
ENVIRONMENTAL TEST DATA
According to IEC 60384-17, Grade 1.1 and Quality tests and requirements for Pulse
Capacitors in the Evox Rifa Film Capacitors catalogue.
p d std I max I b 7.5±0.40.65-130± 0.410.0±0.40.65-130± 0.415.0±0.40.86-130± 0.422.5±0.40.86-130± 0.427.5±0.40.86-130± 0.437.5
±0.5
1.0
6-1
30
± 0.7
Three different winding constructions are used, depending on voltage and lead spacing. They are specified in the article table.
2 section construction
3 section construction
235
PHE450
µF F F
µF F
PHE450
236
PHE450
237
PHE450
238
PHE450
239
PHE450
240
PHE450
241
PHE450
242
PHE450
243
PHE450
244
PHE450
245。

相关文档
最新文档