无极灯EMC测试报告
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
无极灯EMC测试报告
EMC TEST REPORT
for
Xiamen RuiMeng Environmental Protection Technology Co., Ltd.
Electromagnetic Induction Lighting
Model No: List of the model No. refer the appendix I
Report No. : ATE20110727 Date of Test : May 2-3, 2011 Date of Report : May 4, 2011
Prepared for : Xiamen RuiMeng Environmental Protection Technology
Co., Ltd.
Address : Rm 702, No.16, Tong’An Industrial Park, Xiamen East Coastal Area, P.R.C
Prepared By : Accurate Technology Co., Ltd.
Address : F1, Bldg. A&D, Changyuan New Material Port, Keyuan Rd. Science & Industry Park, Nanshan District, Shenzhen 518057, P.R. China Tel: +86-755-26503290 Fax: +86-755-26503396
TABLE OF CONTENTS
Description Page
Test Report Declaration
1.TEST RESULTS SUMMARY (6)
2.GENERAL INFORMATION (7)
2.1.Description of Device (EUT) (7)
2.2.Accessory and Auxiliary Equipment (7)
2.3.Description of Test Facility (8)
2.4.Measurement Uncertainty (8)
3.MEASURING DEVICES AND TEST EQUIPMENT (9)
3.1.For Conducted Emission Test (9)
3.2.For Magnetic Measurement (9)
3.3.For Radiated Emission Measurement (10)
3.4.For Harmonic & Flicker Test (10)
3.5.For Electrostatic Discharge Immunity Test (10)
3.6.For RF Strength Susceptibility Test (11)
3.7.For Electrical Fast Transient /Burst Immunity Test (11) 3.8.For Surge Immunity Test (11)
3.9.For Injected Current Susceptibility Test (11)
3.10.For Magnetic Field Immunity Test (12)
3.11.For Voltage Dips and Interruptions Test (12)
4.POWER LINE CONDUCTED MEASUREMENT (13)
4.1.Block Diagram of Test Setup (13)
4.2.Measurement Standard and Limits (13)
4.3.Power Line Conducted Emission Limits (13)
4.4.EUT Configuration on Measurement (13)
4.5.Operating Condition of EUT (14)
4.6.Test Procedure (14)
4.7.Measurement Results (15)
5.MAGNETIC FIELD EMISSION MEASUREMENT (17)
5.1.Block Diagram of Test Setup (17)
5.2.Measurement Standard (17)
5.3.Magnetic Field Emission Limits (17)
5.4.EUT Configuration on Measurement (17)
5.5.Operating Condition of EUT (17)
5.6.Test Procedure (18)
5.7.Test Results (19)
6.RADIATED EMISSION MEASUREMENT (23)
6.1.Block Diagram of Test (23)
6.2.Measuring Standard (23)
6.3.Radiated Emission Limits (24)
6.4.EUT Configuration on Test (24)
6.5.Operating Condition of EUT (24)
6.6.Test Procedure (24)
6.7.Measuring Results (25)
7.HARMONIC CURRENT MEASUREMENT (27)
7.1.Block Diagram of Test Setup (27)
7.2.Measuring Standard (27)
7.3.Operating Condition of EUT (27)
7.4.Test Results (27)
8.VOLTAGE FLUCTUATIONS & FLICKER MEASUREMENT (31) 8.1.Block Diagram of Test Setup (31)
8.2.Measuring Standard (31)
8.3.Operating Condition of EUT (31)
8.4.Test Results (31)
9.ELECTROSTATIC DISCHARGE TEST (33)
9.1.Block Diagram of Test Setup (33)
9.2.Test Standard (33)
9.3.Severity Levels and Performance Criterion (33)
9.4.EUT Configuration (34)
9.5.Operating Condition of EUT (34)
9.6.Test Procedure (34)
9.7.Test Results (34)
10.RF FIELD STRENGTH SUSCEPTIBILITY TEST (36)
10.1.Block Diagram of Test Setup (36)
10.2.Test Standard (36)
10.3.Severity Levels and Performance Criterion (37)
10.4.EUT Configuration (37)
10.5.Operating Condition of EUT (37)
10.6.Test Procedure (37)
10.7.Test Results (37)
11.ELECTRICAL FAST TRANSIENT/BURST TEST (39) 11.1.Block Diagram of Test Setup (39)
11.2.Test Standard (39)
11.3.Severity Levels and Performance Criterion (39) 11.4.EUT Configuration (39)
11.5.Operating Condition of EUT (40)
11.6.Test Procedure (40)
11.7.Test Result (40)
12.SURGE IMMUNITY TEST (42)
12.1.Block Diagram of Test Setup (42)
12.2.Test Standard (42)
12.3.Severity Levels and Performance Criterion (42) 12.4.EUT Configuration (43)
12.5.Operating Condition of EUT (43)
12.6.Test Procedure (43)
12.7.Test Result (43)
13.INJECTED CURRENTS SUSCEPTIBILITY TEST (45) 13.1.Block Diagram of Test Setup (45)
13.2.Test Standard (45)
13.3.Severity Levels and Performance Criterion (45) 13.4.EUT Configuration (46)
13.5.Operating Condition of EUT (46)
13.6.Test Procedure (46)
13.7.Test Results (46)
14.MAGNETIC FIELD IMMUNITY TEST (48)
14.1.Block Diagram of Test Setup (48)
14.2.Test Standard (48)
14.3.Severity Levels and Performance Criterion (48) 14.4.EUT Configuration (49)
14.5.Operating Condition of EUT (49)
14.6.Test Procedure (49)
14.7.Test Results (49)
15.VOLTAGE DIPS AND INTERRUPTIONS TEST (51)
15.1.Block Diagram of Test Setup (51)
15.2.Test Standard (51)
15.3.Severity Levels and Performance Criterion (51)
15.4.EUT Configuration (52)
15.5.Operating Condition of EUT (52)
15.6.Test Procedure (52)
15.7.Test Result (52)
16.PHOTOGRAPH (54)
16.1.Photo of Conducted Emission Measurement (54)
16.2.Photo of Radiated Measurement (54)
16.3.Photo of Electrostatic Discharge Test (55)
16.4.Photo of RF Field Strength Susceptibility Test (56)
16.5.Photo of Electrical Fast Transient /Burst Test (56)
16.6.Photo of Surge and Voltage Dips and Interruption Immunity Test (57)
16.7.Photo of Injected Current Susceptibility Test (57)
16.8.Photo of Magnetic Field Immunity Test (58)
16.9.Photo of EUT (58)
TEST REPORT DECLARATION
Applicant : Xiamen RuiMeng Environmental Protection Technology Co.,
Ltd.
Manufacturer : Xiamen RuiMeng Environmental Protection Technology Co.,
Ltd.
Product : Electromagnetic Induction Lighting
Model No. : List of the model No. refer the appendix I
Measurement Procedure Used:
EN 55015: 2006 + A1: 2007 + A2: 2009
EN 61000-3-2:2006 + A1:2009 +A2: 2009
EN 61000-3-3: 2008
EN 61547: 2009 (IEC61000-4-2: 2008
IEC61000-4-3: 2010
IEC61000-4-4: 2004
IEC61000-4-5: 2005
IEC61000-4-6: 2008
IEC61000-4-8: 2009
IEC61000-4-11: 2004)
The device described above is tested by Accurate Technology Co., Ltd. To determine
the maximum emission levels emanating from the device and the severe levels of the
device can endure and its performance criterion. The measurement results are
contained in this test report and Accurate Technology Co., Ltd. is assumed full
responsibility for the accuracy and completeness of these measurements. Also, this
report shows that the EUT to be technically compliant with the EN 55015, EN
61000-3-2, EN 61000-3-3 and EN 61547 requirements.
This report applies to above tested sample only and shall not be reproduced in part
without written approval of Accurate Technology Co., Ltd.
Date of Test : May 2-3, 2011
Prepared by :
(Engineer)
Approved & Authorized Signer :
(Manager)
1. TEST RESULTS SUMMARY
Test Items Test Standard Test Results
Power Line Conducted Emission
EN 55015: 2006 +
A1: 2007 + A2: 2009
Pass
Magnetic Field Emission
EN 55015: 2006 +
A1: 2007 + A2: 2009
Pass
Radiated Emission
EN 55015: 2006 +
A1: 2007 + A2: 2009
Pass
Harmonic Current EN 61000-3-2:2006 +
A1:2009 +A2: 2009
Pass
Voltage Fluctuation and Flicker EN 61000-3-3: 2008 Pass Electrostatic Discharge Immunity EN 61547: 2009 (IEC61000-4-2:
2008)
Pass
Radiated Electromagnetic Fields Immunity EN 61547: 2009 (IEC61000-4-3:
2010)
Pass
Electrical Fast Transients/Bursts Immunity EN 61547: 2009 (IEC61000-4-4:
2004)
Pass
Surge Immunity EN 61547: 2009
(IEC61000-4-5:
2005)
Pass
Injected Current Susceptibility Test EN 61547: 2009
(IEC61000-4-6:
2008)
Pass
Magnetic Field Immunity EN 61547: 2009
(IEC61000-4-8:
2009)
Pass
Voltage dips and interruptions Immunity EN 61547: 2009 (IEC61000-4-11:
2004)
Pass
2. GENERAL INFORMATION
2.1.Description of Device (EUT)
Product : Electromagnetic Induction Lighting
Model Number : List of the model No. refer the appendix I (Note: These samples are identical, except the power is
difference. Therefore only
model RM-EIL-HB-004 80W-200W is tested for EMC tests.) Rating : AC 230V/50Hz
Applicant : Xiamen RuiMeng Environmental Protection Technology Co.,
Ltd.
Address : Rm 702, No.16, Tong’An Industrial Park, Xiamen East
Coastal Area, P.R.C
Manufacturer : Xiamen RuiMeng Environmental Protection Technology Co.,
Ltd.
Address : Rm 702, No.16, Tong’An Industrial Park, Xiamen East
Coastal Area, P.R.C
Date of sample
: April 29, 2011
receiver
Date of Test : May 2-3, 2011
2.2.Accessory and Auxiliary Equipment
n.a.
2.3.Description of Test Facility
EMC Lab :Accredited by TUV Rheinland Shenzhen
Listed by FCC
The Registration Number is 253065
Listed by FCC
The Registration Number is 752051
Listed by Industry Canada
The Registration Number is 5077A-1
Listed by Industry Canada
The Registration Number is 5077A-2
Accredited by China National Accreditation Committee
for Laboratories
The Certificate Registration Number is L3193
Name of Firm :ACCURATE TECHNOLOGY CO. LTD
Site Location :F1, Bldg. A, Changyuan New Material Port, Keyuan
Rd. Science & Industry Park, Nanshan, Shenzhen,
Guangdong P.R. China
Subcontracted Items::Magnetic Measurement Test
RF Strength Susceptibility Test
Subcontractor :Shenzhen Academy Of Metrology And Quality
Inspection
Site Location :Bldg. Of Shenzhen Academy Of Metrology And Quality Inspection, Longzhu Road, Nanshan,
Shenzhen, Guangdong P. R. China
2.4.Measurement Uncertainty
Conducted emission expanded uncertainty : U=2.23dB, k=2 Power disturbance expanded uncertainty : U=2.92dB, k=2
Radiated emission expanded uncertainty
: U= 3.08dB, k= 2 (9kHz-30MHz)
Radiated emission expanded uncertainty
: U= 4.42dB, k= 2 (30MHz-1000MHz)
Radiated emission expanded uncertainty
: U= 4.06dB, k= 2 (Above 1GHz)
3. MEASURING DEVICES AND TEST EQUIPMENT
3.1.For Conducted Emission Test
Item Equipment Manufacturer Model No.Serial No. Last Cal. Cal. Interval
1. Test Receiver Rohde & Schwarz ESCS30 100307 Jan. 15, 20111 Year
2. Test Receiver Rohde & Schwarz ESPI3 100396/003 Jan. 15, 20111 Year
3. Test Receiver Rohde & Schwarz ESPI3 101526/003 Jan. 15, 20111 Year
4. L.I.S.N. Schwarzbeck NSLK81268126431 Jan. 15, 20111 Year
5. L.I.S.N. Rohde & Schwarz ESH3-Z5 100305 Jan. 15, 20111 Year
6. L.I.S.N. Rohde & Schwarz ESH3-Z5 100310 Jan. 15, 20111 Year
7. L.I.S.N. Rohde & Schwarz ESH3-Z6 100132 Jan. 15, 20111 Year
8. Pulse Limiter Rohde & Schwarz ESH3-Z2 100305 Jan. 15, 20111 Year
9. Pulse Limiter Rohde & Schwarz ESH3-Z2 100312 Jan. 15, 20111 Year
10. Pulse Limiter Rohde & Schwarz ESH3-Z2 100815 Jan. 15, 20111 Year
11. 50? Coaxial
Switch
Anritsu Corp MP59B 620028393
6
Jan. 15, 20111 Year
12. 50? Coaxial
Switch
Anritsu Corp MP59B 620028393
3
Jan. 15, 20111 Year
13. 50? Coaxial
Switch
Anritsu Corp MP59B 620050647
4
Jan. 15, 20111 Year
14. RF Coaxial
Cable
SUHNER N-2m No.2 Jan. 15, 20111 Year
15. RF Coaxial
Cable
SUHNER N-2m No.3 Jan. 15, 20111 Year
16. RF Coaxial
Cable
SUHNER N-2m No.13 Jan. 15, 20111 Year 3.2.For Magnetic Measurement
Item Equipment Manufacturer Model No. Serial No.NO. Last Cal. Cal.
Interval
1. EMI Test Receiver Rohde &
Schwarz ESCS30 100003 SB33
19
Jan 23, 2011 1 Year
2. Triple Loop
Antenna
Schwarzbeck HXYZ91709124 9124 Jan 23, 2011 1 Year
3.3. F or Radiated Emission Measurement
Item Equipment
Manufacturer
Model No.
Serial No.
Last Cal.
Cal.
Interval 1. Spectrum Analyzer ANRITSU MS2651B 6200238856 Jan. 15, 2011 1 Year 2. Spectrum Analyzer Agilent E7405A MY45115511 Jan. 15, 2011 1 Year 3. Test Receiver Rohde&Schwarz ESCS30 100307 Jan. 15, 2011 1 Year 4. Test Receiver Rohde& Schwarz ESPI3 100396/003 Jan. 15, 2011 1 Year 5. Test Receiver Rohde& Schwarz ESPI3 101526/003 Jan. 15, 2011 1 Year 6. Bilog Antenna Schwarzbeck VULB9163 9163-194 Jan. 15, 2011 1 Year 7. Bilog Antenna Schwarzbeck VULB9163 9163-323 Jan. 15, 2011 1 Year 8. Loop Antenna Schwarzbeck FMZB1516 1516131 Jan. 15, 2011 1 Year 9. Horn Antenna Schwarzbeck BBHA9120D 9120D-655 Jan. 15, 2011 1 Year 10. Horn Antenna Schwarzbeck BBHA9170 9170-359 Jan. 15, 2011 1 Year 11. 50 Coaxial Switch Anritsu Corp MP59B 6200237248 Jan. 15, 2011 1 Year 12. 50 Coaxial Switch Anritsu Corp MP59B 6200506474 Jan. 15, 2011 1 Year 13. RF Coaxial Cable Schwarzbeck N-5m No.1 Jan. 15, 2011 1 Year 14. RF Coaxial Cable Schwarzbeck N-1m No.6 Jan. 15, 2011 1 Year 15. RF Coaxial Cable Schwarzbeck N-1m No.7 Jan. 15, 2011 1 Year 16. RF Coaxial Cable SUHNER N-3m No.8 Jan. 15, 2011 1 Year 17. RF Coaxial Cable RESENBERGER N-3.5m No.9 Jan. 15, 2011 1 Year 18. RF Coaxial Cable SUHNER N-6m No.10 Jan. 15, 2011 1 Year 19. RF Coaxial Cable RESENBERGER N-12m No.11 Jan. 15, 2011 1 Year 20. RF Coaxial Cable RESENBERGER N-0.5m No.12 Jan. 15, 2011 1 Year 21. Pre-Amplifier Agilent 8447D 294A10619 Jan. 15, 2011 1 Year 22. Pre-Amplifier Rohde&Schwarz CBLU11835
40-01
3791 Jan. 15, 2011
1 Year
3.4.For Harmonic & Flicker Test
3.5.For Electrostatic Discharge Immunity Test
Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. ESD Tester
HAEFELY PESD1610 H4001552Jan. 15, 20111 Year
Item Equipment Manufacturer Model No. Serial No. Last Cal.
Cal. Interval
1. AC Power Source California Instruments
5001iX-40055689 Jan. 15, 2011
1Year 2. Test analyzer California Instruments
PACS-1 72254 Jan. 15, 2011
1Year 3. PC Lenovo L4000 SA03697426 N/A
N/A
3.6.For RF Strength Susceptibility Test
Item Equipment Manufacturer
Model No.
Serial No. Last Cal. Cal. Interval 1. Signal Generator Rohde&Schwarz SMT03 100059 Jan. 23, 2011 1 Year 2. Voltage Probe Rohde&Schwarz URV5-Z2 100013 Jan. 23, 2011 1 Year 3. Power Amplifier AR 150W1000 300999 Jan. 23, 2011 1 Year 4. Power Amplifier AR 25S1G4AM1305993 Mar. 9, 2010 2 Year 5. Bilog Antenna
Chase CBL6111C 2576 Jan. 23, 2011 1 Year 6. Anechoic chamber
Albatross Projects MCDC
----
Mar. 20, 2010
2 Year
3.7.For Electrical Fast Transient /Burst Immunity Test
Item Equipment Manufacturer Model No. Serial st Cal.
Cal. Interval
1. ULTRA COMPACT SIMULATOR EM TEST
UCS 500 N5V0928104968
Jan. 15, 20111Year
2. CAPACITIVE CLAMP
EM TEST
HFK 0509-34 Jan. 15, 20111Year 3. Transformer EM TEST
V4780S2
0109-44
Jan. 15, 20111Year
3.8.For Surge Immunity Test
Item Equipment Manufacturer
Model No. Serial st Cal. Cal. Interval
1. ULTRA COMPACT SIMULATOR EM TEST
UCS 500 N5 V0928104968
Jan. 15, 20111Year 2. Transformer EM TEST
V4780S2 0109-44 Jan. 15, 20111Year
3.9.For Injected Current Susceptibility Test
Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Conducted Immunity Test System FRANKONIA CIT-10 126B1121 Jan. 15, 2011 1Year
2. CDN FRANKONIA CDN-M2/3 A3027020 Jan. 15, 2011
1Year
3. EM Injection Clamp FCC F-203I-23mm 091824 Jan. 15, 2011 1Year
4. Calibration Fixture FCC F-203I-23mm-CF
091822 N.A. N.A.
5. 6dB Attenuator Weinschel WA59-6-33 A329 Jan. 15, 2011
1Year
6. 150/50 ohms Adaptor
Frankonia N/A 025 N.A. N.A.
3.10.For Magnetic Field Immunity Test
Item Equipment Manufacturer Model No.Serial st Cal. Cal. Interval 1. Magnetic Field Tester HAEFELY MAG100 150577 Jan. 15, 2011 1 Year
2. AC Transformer HOKUN TDGC2J-5N/A N/A N/A
3.11.For Voltage Dips and Interruptions Test
Item Equipment Manufacturer Model No. Serial st Cal. Cal. Interval
1. ULTRA COMPACT SIMULATOR EM TEST
UCS 500 N5 V0928104968
Jan. 15, 20111Year 2. Transformer EM TEST
V4780S2 0109-44 Jan. 15, 20111Year
4. POWER LINE CONDUCTED MEASUREMENT
4.1.Block Diagram of Test Setup
(EUT: Electromagnetic Induction Lighting )
4.2. M easurement Standard and Limits
EN 55015: 2006 + A1: 2007 + A2: 2009
4.3. P ower Line Conducted Emission Limits
At mains terminals dB( V)
Frequency
Quasi-peak Level Average Level
9kHz - 50KHz 110
-- 50kHz - 150KHz 90 - 80* -- 150kHz - 0.5MHz 66 - 56* 56 - 46* 0.5MHz - 5.0MHz 56 46 5.0MHz - 30.0MHz 60 50 1. At the
transition frequency the lower limit applies. 2. * Decreasing linearly with logarithm of the frequency.
4.4. E UT Configuration on Measurement
The following equipments are installed on Conducted Emission Measurement
to meet EN55015 requirements and operating in a manner which tends to maximize its emission characteristics in a normal application. 4.4.1.Electromagnetic Induction Lighting (EUT) Model No.
:RM-EIL-HB-004 80W-200W Serial No. :N/A
Manufacturer
:Xiamen RuiMeng Environmental Protection Technology Co., Ltd.
4.5.Operating Condition of EUT
4.5.1.Setup the EUT as shown in Section 4.1.
4.5.2.Turn on the power of all equipments.
4.5.3.Let the EUT work in test mode (On) and measure it.
4.6. T est Procedure
The EUT is put on the table which is 0.8 meter high above the ground and connected to the AC mains through a Line Impedance Stabilization Network (L.I.S.N.). This provided a 50ohm coupling impedance for the tested equipments. Both sides of AC line are checked to find out the maximum conducted emission according to the EN 55015 regulations during conducted emission measurement. And the voltage probe had been used for the load terminals measurement according to the EN 55015 standard.
The bandwidth of the test receiver (R&S ESCS30) is set at 200Hz in 9k~150kHz range and 9kHz in 150k~30MHz range.
The frequency range from 9 kHz to 30MHz is checked.
4.7.Measurement Results
PASS.
The frequency range 9 kHz to 30MHz is investigated.
Test mode: On
Emissions attenuated more than 20 dB below the permissible value are not reported.
The spectral diagrams are shown in the following pages.
Ambient temperature: 25oC Relative humidity: 50% Test
Mode: On
Test Specification: Line
Ambient temperature: 25oC Relative humidity: 50% Test Mode: On
Test Specification: Neutral
5. MAGNETIC FIELD EMISSION MEASUREMENT
5.1.Block Diagram of Test Setup
(EUT: Electromagnetic Induction Lighting )
5.2.Measurement Standard
EN 55015: 2006 + A1: 2007 + A2: 2009
5.3.Magnetic Field Emission Limits
Limits for loop diameter dB( A) Frequency
2m
9kHz - 70kHz 88
70kHz - 150kHz 88 -58*
150kHz - 3.0MHz 58 - 22*
3.0MHz - 30MHz 22
1. At the transition frequency the lower limit applies.
2. * Decreasing linearly with logarithm of the frequency.
5.4.EUT Configuration on Measurement
The configuration of the EUT is same as Section 4.4.
5.5.Operating Condition of EUT
5.5.1.Setup the EUT as shown in Section 5.1.
5.5.2.Turn on the power of all equipments.
5.5.3.Let the EUT work in test mode (On) and measure it.
5.6.Test Procedure
The EUT is placed on a wood table in the center of a loop antenna. The induced current in the loop antenna is measured by means of a current probe and the test receiver. Three field components are checked by means of a coaxial switch.
The frequency range from 9 kHz to 30MHz is investigated. The receiver is measured with the quasi-peak detector. For frequency band 9 kHz to 150 kHz, the bandwidth of the field strength meter (R&S test receiver ESCS30) is set at 200Hz. For frequency band 150 kHz to 30MHz, the bandwidth is set at 9 kHz.
5.7.Test Results
PASS.
The frequency range from 9 kHz to 30MHz is investigated.
Emissions attenuated more than 20 dB below the permissible value are not reported.
The spectral diagrams are shown in the following pages.。