DZ47sLES RESIDUAL CURRENT OPERATED
CIRCUIT-BREAKER NAVIGATOR
Series User Manual
Please carefully read this User Manual before installing and operating the product, and keep this manual properly for future
reference
Safety Notice
Please carefully read this manual before the installation, operation, run, maintenance, and inspection of the product, and install and operate this product properly according to the contents of the instructions.
Danger:
⚫It is prohibited to operate the circuit breaker with your wet hands;
⚫It is prohibited to touch the conductive part during operation;
⚫Make sure that the product is de-electrified during the maintenance and service;
⚫It is prohibited to use the short circuit method to test the product;
Caution:
⚫The installation, maintenance, and service shall be carried out by the qualified professionals;
⚫All characteristics of the product have been set in the factory, and the product cannot be disassembled without permission or adjusted at will during operation;
⚫Please confirm that the product voltage, rated current, frequency, and characteristics of the product meet the working requirements before use;
⚫Connect the wire according to the wiring mark on the product (the load end is the outlet terminal); tighten the wiring screw when the wire is inserted into the wiring hole, and fasten the wire until it cannot be loose or pulled out; the exposed copper wire head shall not be exposed outside the terminal block;
⚫This product cannot provide the protection for electric shock caused by contact with two wires of the protected circuit simultaneously;
⚫This product has an IP20 protection level without dustproof protection. Therefore, when used in a dusty place, it shall be installed in a well-sealed terminal box;
⚫When there is voltage on the power supply side, the circuit board of the product is in the working state after power-on and here is a certain temperature on the side, and this belongs to the normal phenomenon;
⚫This product is not suitable for some special applications such as frequent motor starting, electric heating equipment, capacitor cabinets, high inductive and high capacitive loads and high temperature environments;
⚫If found damage or heard abnormal sound when unpacking the product, please stop the operation immediately and contact the supplier;
Table of Contents
1 Main Purpose and Scope of Application…………………………............................................................................
2 Product Model and Its Meanings (1)
2.1 Product Model and Its Meanings................................................................... .. (1)
2.2 Panel Introduction (2)
3 Normal Working Conditions and Installation Conditions (2)
4 Technical Characteristics................................................................... (3)
4.1 Classification (3)
4.2 Main Technical Parameters (3)
4.3 Main Technical Performances (4)
5 Outline and Installation Dimensions (4)
6 Installation, Operation and Maintenance............................................. .. (5)
7 Troubleshooting............................................. . (6)
8 Unpacking Inspection............................................. . (7)
9 Company’s commitments............................................. . (7)
1 Main Purpose and Scope of Application
DZ47sLES series residual current operated circuit breaker (hereinafter referred to as leakage circuit breaker) has electric leakage (electric shock), overload, and short circuit protection functions, and can also have over-voltage and under-voltage protection functions according to the needs of users.
DZ47sLES leakage circuit breaker is used in the AC 50/60Hz lines with rated voltage 230V/400V and rated current up to 63A for indirect contact protection of people, as well as overcurrent protection for buildings and similar lines. It can also provide protection against fires caused by persistent earth faults due to the non-operation of the overcurrent protection device. Leakage circuit breakers with overvoltage protection can also provide the production against excessive voltage increases due to grid faults.
This series of products has been increasingly used in low-voltage power distribution systems as a backup protection against earth faults, direct contact and indirect contact electric shocks.
The circuit breaker is equipped with 6 different accessories, including: OF auxiliary contact, MX+OF shunt releases, SD alarm contact, MV overvoltage release, MN undervoltage release and MVMN overvoltage and undervoltage release. When there are multiple accessories installed, the size for maximum number of installations is less than 54mm.
2 Product Model and Its Meanings
2.1 Product Model and Its Meanings
Accessory code: By default: Common type; G: Overvoltage type
Derived code: Electronic leakage circuit breaker
Product series number
Design No.
Product code
2.2 Panel Introduction
Press before
power-on
Press once a month
Load end
Legends:
1 Inlet terminal
2 Company Logo
3 Product model (overvoltage model DZ47sLES G)
4 Trip curve and rated current (see Table 1)
5 Rated voltage (see Table 1)
6 Breaking capacity and frequency (see Table 1)
7 Reference standards
8 Certification marks
9 Identification on load end 10 N-pole marking 11 Reset button
12. Rated residual making and breaking capacity, rated residual operating current, rated operating time, (overvoltage protection parameter is Uvo= (280±5%)V)
13 Wiring diagram 14 Test button 15 Outline terminal
3 Normal Working Conditions and Installation Conditions
a) Ambient air temperature:
The upper limit of the ambient air temperature does not exceed +70°C, the lower limit does not below -35°C, and the mean temperature does not exceed +35°C within 24 hours; note: If the residual current operated circuit breaker is used in places where the ambient air temperature is higher than +70°C or below -35°C, please contact the manufacturer;
b) Altitude
The altitude of the installation site does not exceed 2000m;
c) Atmospheric conditions:
When the temperature is +60°C, the relative humidity of the air does not exceed 50%; a higher relative humidity is allowed at lower temperatures; for example, when the temperature is +20°C, the relative humidity does not exceed 90%. Special protection measures should be taken for condensation occurred occasionally due to temperature changes;
d) Installation conditions:
The external magnetic field near the installation site of the residual current operated circuit breaker should not exceed 5 times of the geomagnetic magnetic field in any direction; the installation position should be vertical, and the inclination angle in any direction should not exceed 10°; the product is installed in a place where there is no shock vibration and no rain or snow erosion; the standard TH35-7.5 steel installation rails are used for installation;
e)Pollution degree: Level 2;
f)Installation category: Class II, Class III;
g)Protection grade: IP20 (Installed a power distribution tank, distribution cabinet or box: IP40);
h)For product with a N pole, please connect the zero line to the pole marked with N when wiring.
i)Normal storage and transport conditions
a)Temperature: -40°C~ +85°C;
b)Relative humidity (at 25°C): ≤95%;
c)Please handle the product gently during transportation, do not upside it down, and avoid strong collisions.
4 Technical Characteristics
4.1 Classification
a) According to the type of trip: Type B, type C, type D;
b) According to the number of poles of the product: 1P+N, 2P (with and overcurrent protection pole), 3P, 3P+N, 4P;
c) According to the rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;
d) According to the characteristics of leakage action: 10mA, 30mA, 50mA, 75mA, 100mA, 300mA.
4.2 Main Technical Parameters
4.3 Main Technical Performance
a) Overcurrent release protection characteristics see Table 2
b) Mechanical and electrical life
1. Mechanical life: 20,000 times;
2. Electrical life: 10,000 times.
c) The protection characteristic curves of the circuit breaker are illustrated in Fig. 1.
Fig. 1 B type thermal / electromagnetic trip characteristics
curve
Fig. 2 C type thermal /
electromagnetic trip characteristics
curve
Fig. 3 D type thermal /
electromagnetic trip characteristics
curve
5 Outline and Installation Dimensions
The outline and installation dimensions are illustrated in Fig. 1.
Fig. 1 Outline and installation dimensions
6 Installation, Operation and Maintenance
a)Check whether the product mark is consistent with the conditions used before installation;
b)Correctly connect the wires at the inlet terminal and outlet terminal according to the product identification (the load current should be less than the rated current of the product);
c)The N pole shall be connected correctly, and must be reliably wired, otherwise the product will not work normally;
d)When installation, insert the residual current operated circuit breaker into the mounting rail until the residual current operated circuit breaker is fixed on it without looseness and fall-off. To dismantle the residual current operated circuit breaker, pull out the stopper.
e)The rated tightening torque is 2.0N.m;
f)The cross-sectional area of the connecting wire sees Table 3;
Table 3 Sectional-area and rated current of the connecting (copper) wire
Rated current A 6 10 16, 20 25 32 40, 50 63
Sectional area of wire mm 2 1 1.5 2.5 4 6 10
16
g) After power-on, operate the residual current operated circuit breaker test button several times and confirm whether it works reliably;
h) The working reference temperature of the residual current operated circuit breaker is +30+50℃. When the ambient temperature changes, its rated value shall be corrected, and the temperature correction coefficient is listed in Table 4; if multiple residual current operated circuit breakers are installed in the same closed box, the temperature in the box will be increased accordingly, and the rated current should be multiplied by derating coefficient 0.8.
7 Table 4 Rated current temperature correction coefficient table
Temp.
Rated current (A)
j) Maintenance
After the residual current operated circuit breaker is running for some time, it shall be checked regularly (monthly). After the circuit breaker is powered on and energized, press the test button and check the residual current operated circuit breaker can work reliably. If failure to work normally, please replace it immediately and do not operate it continuously.
7 Troubleshooting
The faults and troubleshooting of the residual current operated circuit breaker see Table 5.
Table 5 Fault and troubleshooting
Fault Cause Solution
M i s -o p e r a t i o n
Mis-operation caused by zero line earthed at the load side of the residual current operated circuit breaker When the zero line on the load side of the residual current operated circuit breaker is earthed, the normal operating current will flow in through the earth point to cause mis-operation.
Residual current operated circuit breaker
Incorrect wiring
Connect the earth wire to the zero line at the power side of the residual current
operated circuit breaker
Residual current operated circuit breaker
Correct wiring Mis-operation by
the leakage current and the current of
the wire to
capacitor
Wire on the load side is laid tightly on the
ground too long
Select the residual current operated circuit breaker with a large residual operating current The leakage current of the wire on the load
side to earth is increased due to insulation
reduction.
Replace wire
8 Unpacking Inspection
After unpacking, the user must check whether the product is intact, whether the exposed metal is rusty, and whether the product is defects due to poor transportation or storage. If found the above phenomenon, please stop the product, and contact the supplier timely for solution.
9 Company’ commitment
The free repair or replacement will be provided by the company for damage or abnormal operation of the product produced by our company due to poor manufacturing quality within 36 months from the date of the production under the premise that the user conforms to the operation and storage conditions and that the product is well sealed.
A paid repair is provided when the warranty period expires. However, the paid repair is provided for damage caused by one of the following situations even within the warranty period:
a)Improper operation, maintenance, or storage;
b)Modification without permission, or improper maintenance;
c)Damage caused by falling off after purchase or occurred during the installation process;
d)Irresistible nature disasters such as earthquakes, fires, lightning strikes, and abnormal voltages.
If you have any questions, please contact the dealer or the company’s customer service department.Customer service hotline: 400-826-8008