电加热器说明书
电热水器使用说明书
MT:手动复位温控器 EH:电热管 H1:1500W接线端 H2:1000W接线端 RY:继电器 蓝色
N 黄绿色
L
E
棕色
MT 蓝色
棕色
5
1
4
7
3
86
2
N-IN
N-OUT RY1
蓝色
1500W-OUT RY2
L-IN
RY3 1000W-OUT
红色 棕色
H1 H2 EH
Fi3机 型 电 气 原 理 图
1:显示屏 2:开/关键 3:变频键 4:模式键 5:设定键 6:调速键 7:加键 8:减键
450
G1/2"
40。
337
AM100H 911
100
245
450
G1/2"
40。
489
2
M
M
D D
E
B
A
E
B
C A
AM40SH AM50SH AM60SH AM65H AM80H AM100H
2.4 接线图与电气原理图
3
接 线 图
F C
F3机型接线图
3
Fi3机型接线图
4
F3机型电气原理图
1:显示屏 2:开/关键 3:定时键 4:模式键 5:设定键 6:调速键 7:加键 8:减键
2
2.3 外形尺寸
型号
A
B
C
D
E
F
M
AM40SH 647
100
196
353
G1/2"
40。
298
AM50SH 783
100
196
353
G1/2"
SKF TIH 220m大型感应式加热器 说明书
大型感应式加热器
使用说明书
目录
符合欧盟电气产品条例的声明 ...............................................................................................4 安全需知 ..................................................................................................................................5 1. 简介 .....................................................................................................................................6
2006 年 12 月,荷兰
Sebastien David 产品开发与质量经理
TIH 220m
4
安全需知
安全需知
由于 TIH 220m 加热器在工作时会产生磁场,因此在使用时,带心脏起博器的人不可以站 在距加热器周围 5 米范围内。另外一些电子产品,如手表,也会受到电磁场的影响。
在加热过程中,请保持距离工件、加热器线圈或铁芯 50cm 确的电源电压。 在 TIH 220m 加热器和被加热的工件之间存在电位时,有可能产生电弧。但这对人体没危
电磁感应线圈
TIH 220m
6
把要加热的工件套在电磁感应线圈上,这样的设计提高了加热效率,减少了能耗,更快地加 热,从而降低加热每一套轴承所需的成本。 可折叠的支撑地脚 为了能支撑套在电磁感应线圈上的大型轴承,TIH 220m 电磁感应加热器采用了可折叠的三脚支 撑结构。参见本说明书最前面的示意图。 滑动磁轭 在将轴承套上电磁感应线圈或者是挂在磁轭上时,为便于操作,TIH 220m 的大尺寸的磁轭配有 滑动装置。 磁轭存储室 小尺寸的磁轭可以放在加热器的磁轭存储室里。磁轭存储室位于折叠支撑脚的后面。参见本说 明书开始时的示意图。
电加热器使用说明书
安装、使用产品前,请仔细阅读使用说明书RJD-25/1140(660)制氮装置用隔爆兼增安型电加热器使用说明书煤科集团研究院有限公司前言本说明书是使用说明书。
本说明书对于初次使用RJD-25/1140(660)型制氮装置用隔爆兼增安型电加热器的用户很有必要,对于具有使用经验的用户,也可使其进一步加深理解,这一点也是编者的宗旨。
希望用户仔细阅读本说明书,完全理解后在付诸实践。
另外,设备在正常运转开始后,设备操作员与维修人员须将此说明书就近保管好,以便需要时参阅。
本说明书的主要容包括RJD-25/1140(660)型制氮装置用隔爆兼增安型电加热器的结构特征与工作原理、技术特征、安装调试使用操作以及维护保养等容。
由于RJD-25/1140(660)型制氮装置用隔爆兼增安型电加热器的研究与改进在不断进行,因此本说明书的容有可能与购买产品的具体情况有不符之处,如对购买产品或本说明书有疑问,请与下述部门联系:TEL:-56626032警告!先启动制氮机,工作稳定后再启动电加热器1.概述1.1主要用途及使用围●该电加热器专门用于矿用井下移动式制氮装置的配套,安装在矿用井下移动式制氮装置。
用于井底车场、总进风巷和主要进风巷,翻车机硐室,采区进风巷。
●品种、规格●RJD-25/1140(660)1.2执行标准及特征1.2.1 型号的组成及其代表意义R J D -25/1140(660)电压等级额定功率制氮装置用隔爆兼增安加热器1.2.2 执行标准执行标准为Q/SMY2222-2015;GB3836-2010。
1.2.3防爆形式矿用隔爆型“ExdeⅠMb”。
1.3基本参数1.4使用环境条件●隔爆型电控制箱能够在下列环境条件下正常工作:➢环境温度:0~40℃;➢相对湿度:≤95%(25℃时);1.5工作条件●电加热器应安置在矿用井下移动式制氮装置。
工作环境的有害气体、瓦斯、煤尘含量和通风量应符合《煤矿安全规程》的规定,具有完整的供电系统,●额定工作电压:1140/660V(AC)●额定的功率:25KW●额定的工作制:长期工作制●制氮机工作稳定后再启动电加热器!!!1.6安全●电加热器的维护和保养工作必须在断电的情况下才能进行。
Warmax使用说明书
Word 文档产品使用说明书HE2000A/HM2000AHE2500A/HM2500AHE3000A/HM3000A尊敬的用户:感谢你选择了美国沃尔麦斯科技有限公司的产品。
请认真阅读并遵循本手册中的安装和维护说明。
你将在今后数年中享受美国沃尔麦斯科技有限公司的加热器产品所带来的舒适温暖。
本产品在中国大陆地区执行以下标准:GB4706.1-2005 家用和类似用途电器的安全通用要求GB4706.23-2007 家用和类似用途电器的安全室内加热器的特殊要求产品型号:室内加热器(对流式踢脚线型电加热器)HE2000A \ HE2500A \ HE3000AHM2000A \ HM2500A \ HM3000A欢迎来到warmax世界请仔细阅读本手册本手册包含正确安装、使用和操作的基本信息,在安装、操作或清洁加热器前,请仔细阅读本手册。
如果不按照本手册程序操作,将有可能导致火灾、触电或严重的人体伤害等。
妥善保管并经常阅读本手册将有助于安全正确使用该加热器。
注意事项:1. 为避免过热,禁止覆盖加热器。
2. 加热器不得直接置于电源插座下面。
3. 在正确的用电环境下使用。
(注:中国大陆地区额定电压为:220V~,50Hz)Word 文档4. 建议配备专用电源线路,由专业人员进行布线(针对2.5KW以上机型)。
5. 必须使用可靠接地的三孔固定插座。
(注:中国大陆地区需使用不小于10A(HM2000A/HE2000A),16A(HM2500A/HE2500A,HM3000A/HE3000A)的三孔扁头固定插座)6. 本机使用耐高温绝缘电源线,参数为:3x1.0mm2(HM2000A/HE2000A),3x1.5mm2(HM2500A/HE2500A/HM3000A/HE3000A)。
7. 通电使用时,确保加热器直立放置,严禁倒置或平放使用。
.8. 禁止自行拆卸加热器,有问题时,请与本公司维修部门联系。
9. 当你外出或长时间不使用加热器时,请关掉加热器,并拔出电源插头。
风道式工业电加热器产品说明书
风道式工业加热器使用说明书目录一、公司介绍 (3)二、产品概述 (3)2.1产品特点 (3)2.2产品参数 (3)三、产品结构及组成 (4)3.1产品的结构 (4)3.2产品的组成 (4)四、产品的安装及调试 (4)4.1设备安装 (4)4.2各部件结构及接线方式 (5)4.3设备调试 (7)五、产品的注意事项 (9)六、常见故障的诊断及排除 (9)七、售后服务体制 (10)7.1设备维护和保养 (10)八、附件 (10)一、公司介绍江苏中热机械设备有限公司坐落在东方湿地之都盐城,是以各类电加热器、搅拌装置、污水处理装置的设计研发、制造安装及销售为一体的生产型企业。
产品广泛应用于机械、电厂、化工、科研等领域。
我们以新颖的生产理念,引高端生产技术,创一流的生产品质。
产品可根据客户的使用需求,进行人性化设计,以满足不同客户的多元化使用需求。
我们的产品凭借优质独特的设计,卓越可靠的质量,闻名遐迩,并受到客户的一致好评!二、产品概述风道式工业电加热器主要用于风道中的空气加热,规格分低温、中温、高温三种形式,在结构上的共同之处是采用了用钢板支撑电热管以减少风机停止时电热管的振动,在接线盒中都装有超温控制装置。
低温型可直接安装在风道上,而中温型、高温型由于结构上的不同,在通道外壁至加热器接线盒夹有100mm 厚的保温材料,一方面减少整个通道的对外散热,另一方面也减少了接线腔内的温度。
2.1产品特点1.电加热管采用外绕波纹式不锈钢带,增加了散热面积,大大提高了热交换效率。
2.加热器设计合理,风阻小,加热均匀,无高、低温死角。
3.双重保护,安全性能好。
在加热器上安装了温控器、熔断器,可以用来控制风道空气温度超温和无无风的情况下工作,确保万无一失。
2.2产品参数电压380三、产品结构及组成本公司竭诚向你提供成套的搅拌设备,也可分开订制。
有关设备的型号、规格、数量,请按供货合同和随机出厂技术文件资料逐一查收,并请熟悉他们的结构及工作原理3.1产品的结构3.2产品的组成风道式工业电加热器是由翅片多支管状电加热元件、箱体、控制系统等几部分组成,翅片式管状电热元件是在金属管内放入高温电阻丝,在空隙部分紧密地填入具有良好绝缘性和导热性能的结晶氧化镁粉,采用管状电热元件做发热体,具有结构先进,热效率高,空气在流通时受热均匀。
YDL系列导热油电加热器安装使用说明书
YDL系列导热油电加热器安装使用说明书江阴市裕丰电化设备厂江阴市裕丰热能自控成套有限公司2009本说明书是对导热油电加热器(以下简称电加热器)进行扼要阐述,以帮助使用单位熟悉其特性,正确掌握安装操作要领,延长设备使用寿命。
一、用途与特点本电加热器是以电为热源,导热油为传热介质,利用油泵强制导热油循环而获得高温、恒热源的工业用电加热器。
在一些工业领域中,需要一种容量小、温度(≤350℃)操作方便且温度恒定的热源,然而象蒸汽锅炉、燃煤热油炉不能满足要求时,导热油电加热器是为满足这方面用户需要而开发的。
它运行压力低,供热温度高且恒温,温度控制精确,热效率高,无烟尘、无污染、无明火,且占地面积小,系国家推广的新一代机电一体化节能产品。
电加热器采用智能数显调节仪和晶闸管、固态继电器组成的交流无接触点无级控温系统,具有温升快、控制精度高,工作温度可任意设定,手动与自动功能,软起动,触发器采用过零变周、定周触发,电加热器起动运行对电网无冲击、干扰,具有完善的报警装置,可以实现自动操作。
二、工艺流程1、导热油由膨胀槽进入滤油器经过过滤油器处理后的导热油借助循环油泵注入电加热器进行闭路循环。
2、导热油在加热器内吸收热能,使出口油温逐渐升高。
3、吸收热能后的导热油进入用热设备,并在其内释放热能,完成一次换热过程,欠后导热油重复上述过程。
如此周而复始不断循环,直至油温达到设定值,并自动保持恒温。
4、膨胀槽与循环管路系统直接相连,当系统中的导热油需要补充时,由膨胀槽提供。
工艺流程简图:1、膨胀槽;2、加热器;3、滤油器;4、循环泵;5、电控箱三、设备安装要点1、安装电加热器时不能碰撞,不倾斜,横置及倒置。
2、应尽量靠近用热设备,缩短供热管路,降低热消耗。
3、整个导热油循环系统与膨胀槽之间位差不得小于1.5米。
4、循环管道材料20号无缝管,法兰Pg16、HG5010、阀门J41HC按管径选配,垫片为柔性石墨缠绕垫片。
5、管道敷设坡度不宜小于3%,坡度应沿介质流动方向下降,在最低点设放油口,最高点设排气口。
电加热器-使用说明书
JR—0.432 型电加热器使用说明书目录用途、基本参数和结构说明1. 用途2. 基本参数3. 结构概述二、使用与维护说明1. 使用说明2. 工作时维护三、设备保温用途、基本参数和结构说明1. 用途本产品用于空分设备的纯化器,系利用电加热发热元件(点加热管),来加热气体(污氮气),用于再生纯化器分子筛。
2. 基本参数3. 结构概述:加热器发热元件由15根不锈钢外壳的棒状电加热管组成,通过管板,折流板将其固定在加热器中。
每根电加热管的一端分别连接到相应的接线铜排上,铜排上接上380V电源,通过功率控制器来调节气体的出口温度。
气体自上而下通过电加热管而得到加热,为减少热量损失,壳体外须进行绝热保温。
本电加热器具有结构简单、使用方便、易于维护,使用寿命长,安全可靠等优点。
更换电加热管,将顶部保护罩拆开,拆去电热管连接软电线,松去电热管压紧螺母,便可更换损坏的电加热管。
二、使用与维护说明1. 使用说明:(1)工作前先检查加热器是否漏气,特别是接线柱部分,如有漏气先消除后再使用。
(2)使用检查接地装置是否可靠(3)使用前对电热管进行绝缘检查,其对地绝缘电阻<1M p ,否则将电热管在150~200C左右烘箱内干燥7~8小时,使其绝缘达到要求后,才能使用。
I(3)接线后,将接线端用胶布或水玻璃等将接线端封好,以保护接线端不易氧化。
(4)使用前检查安全膜是否良好。
2. 工作时维护:(1)本加热器必须先通入气源,在气量达到要求,流速稳定后才可通电,决不可在未通气或气量极少的情况下,开启加热器,以免因电加热管过热而损坏。
在使用过程中如突然停气,应立即切断电源。
(2)工作中经常检查电热管使用情况,接线是否良好、绝缘是否达到要求。
(3)工作中定期清除灰尘及氧化皮等杂物。
(4)经常检查安全膜是否处于完好状态。
(5)按加热要求控制出口温度及通断电操作。
(6)定期检查、校正温度及测量控制仪表。
(7)经常检查保温层完好状态。
YDW系列电加热器说明书样本
4.3电加热器循环系统及管路安装
4.3.1循环系统管路参照YDW系列电加热器供热系统循环示意图(图1)进行施工,系统中各管径应与电加热器出、回油口管径一致,管路应采取保温措施,法兰连接处不宜采用包覆措施。
4.3.2在循环系统最高处应安装排气管及排气阀,以便在运行中定期排放形成的气体产物,排气阀的开关位置应便于操作。
4.3.3膨胀槽严禁安装在电加热器及其它设备的正上方,其底部与系统的最高点垂直距离应不小于1.5米(小型的除外)。膨胀管应联接在距离电加热器1.5米以内的回油管路上(图1所示) ,且膨胀管上不得设置阀门,不得有缩径部分,不作保温。膨胀管需要转弯时,其弯曲角度不宜小于120度。
4.3.4连接电加热器与用热设备的管路时尽量采用低进高出方式,必须在连接前对所有管路和用热设备内腔体进行彻底清理,清除内部积水、异物,为保证管路畅通应尽量减少弯曲。
4.4.2在导热油的使用和保管中严禁混入水,其它液体污物等。
4.4.3在整个加热系统安装,试压完成后即可进行注油,注油时能够在膨胀槽注油盖处注油,注油时打开系统中所有的阀门(放油口除外) ,将导热油徐徐由膨胀槽向系统内注入。
4.4.4注油时应继续开启循环油泵,并经过膨胀槽上液位计观察,至油位稳定于膨胀槽高度2/3位置即可。
( 2)升温至150—180℃保温,排除油中轻组分、挥发物及残余水分,请参照脱水曲线图(图2)进行操作。
( 3)排气脱水完成后应关闭辅助排气管阀,打开排气阀方可投入正常升温运行。
4.5.3升温脱水排气过程有关事项
( 1)升温过程中管路可能会发出碰击的响声,说明系统内有大量的气体或管道不畅,此时应降低升温速度,待气体排除即可消除声响。
电加热器使用说明书
客车电加热器使用说明书一. 技术参数1.环境温度:-40℃~+40℃ 2.海拔高度:≤2500m 3.相对湿度:≤90%(该月平均温度25℃以下) 4.额定工作电压:AC220V 50Hz 5. 额定功率与规格尺寸:二. 工作原理电加热器加热部件采用U 型金属管状电加热元件,每台电加热器安装两根U 型金属管状电热元件,分别接在四位接线端子上,可分两路在外部控制;也可一路控制,需将两根电热元件并接在一起。
三. 安装与接线打开电加热器的罩板,电加热器的背板有两个安装孔,可将电加热器固定在墙壁上,电加热器距地面不小于20cm ,上端距障碍物的距离不小于40cm ,以保证空气的流通。
打开接线盒的盒盖,按控制要求将电源线接在接线端子上,接线要可靠、牢固,以免损坏电加热器,电气原理图见图1。
图1 电气原理图 四. 接地电加热器不带电金属外壳应接地保护,金属外壳有接地标识。
五. 安全防范注意事项1.按照额定工作电压接线。
2.表面保持干燥,清洁。
3.电加热器一般在环境温度-40℃~+40℃,空气相对湿度≤90%的条件下使用。
4.每年冬天使用前应在保证电加热器干燥、洁净、绝缘良好、接线牢固的前提下进行试开,符合电气标准要求及电热器性能后再正常使用。
5.电加热器表面禁止覆盖任何物件。
6.不可将手伸进电加热器外罩内,触摸电热元件等配件,以防烫伤或触电。
7.不可将水或杂物进入电加热器外罩内。
8.不可踩踏电加热器,以防踩坏电加热器外罩。
9. 电加热器停止使用时,应切断电源。
EH1EH2X1。
单相3KW电磁加热器使用说明书
F-19
F-20
F-22
0
0
0
显示输入电流值(出厂默认)
1
0
0
显示热敏电阻测量温度 0-150℃,通过 F-16 和 F-17 来设置控
制温度
2
0
0
显示热敏电偶测量温度 0-500℃,通过 F-16 和 F-17 来设置控
制温度
3
0
0
显示热敏电偶测量温度 0-1000℃,通过 F-16 和 F-17 来设置
7:触摸屏带外接时钟工作模式
8:电磁采暖炉数码彩屏工作模式
9:商用电磁炉工作模式
F-21 外 接 电 位 器 或 外 5-250
0
接 PID 调节功能
关断多功能电压
设置
F-22 PID 设 置 功 能 和 0:通用加热
0
F-19 配合使用
1:外接电位器调节功率,(最大功率
受 F-01 限制)
2:当 F-19 为 2 时,可实现 0-500℃
保护功能动作后,请处理引起的原因后,电磁加热器断电再重新上电,然后开始运转。
出错(报警)定义:
代码 A-01
A-02
A-03
代码 E-01
E-02 E-03 E-04
E-05 E-06 E-07 E-08 EnD
运行警告(仍可继续工作,但必须调整)
描述
原因及排查
线圈离负载距离较远
保温棉过厚、线圈每圈与每圈
减小试试 线圈短路、瞬间电流过大 IGBT 传感器断开或没插好 散热器温度过高、风扇不转或
堵塞、 制定功能才有 制定功能才有 输入或输出电流过大保护 线圈电感量过小 需在 F-14 功能输入密码方可
状态为 15kHz 左右。
电加热器使用说明书
安装、使用产品前,请仔细阅读使用说明书RJD-25/1140(660)制氮装置用隔爆兼增安型电加热器使用说明书煤科集团研究院有限公司前言本说明书是使用说明书。
本说明书对于初次使用RJD-25/1140(660)型制氮装置用隔爆兼增安型电加热器的用户很有必要,对于具有使用经验的用户,也可使其进一步加深理解,这一点也是编者的宗旨。
希望用户仔细阅读本说明书,完全理解后在付诸实践。
另外,设备在正常运转开始后,设备操作员与维修人员须将此说明书就近保管好,以便需要时参阅。
本说明书的主要容包括RJD-25/1140(660)型制氮装置用隔爆兼增安型电加热器的结构特征与工作原理、技术特征、安装调试使用操作以及维护保养等容。
由于RJD-25/1140(660)型制氮装置用隔爆兼增安型电加热器的研究与改进在不断进行,因此本说明书的容有可能与购买产品的具体情况有不符之处,如对购买产品或本说明书有疑问,请与下述部门联系:TEL:-56626032警告!先启动制氮机,工作稳定后再启动电加热器1.概述1.1主要用途及使用围●该电加热器专门用于矿用井下移动式制氮装置的配套,安装在矿用井下移动式制氮装置。
用于井底车场、总进风巷和主要进风巷,翻车机硐室,采区进风巷。
●品种、规格●RJD-25/1140(660)1.2执行标准及特征1.2.1 型号的组成及其代表意义R J D -25/1140(660)电压等级额定功率制氮装置用隔爆兼增安加热器1.2.2 执行标准执行标准为Q/SMY2222-2015;GB3836-2010。
1.2.3防爆形式矿用隔爆型“ExdeⅠMb”。
1.3基本参数1.4使用环境条件●隔爆型电控制箱能够在下列环境条件下正常工作:➢环境温度:0~40℃;➢相对湿度:≤95%(25℃时);1.5工作条件●电加热器应安置在矿用井下移动式制氮装置。
工作环境的有害气体、瓦斯、煤尘含量和通风量应符合《煤矿安全规程》的规定,具有完整的供电系统,●额定工作电压:1140/660V(AC)●额定的功率:25KW●额定的工作制:长期工作制●制氮机工作稳定后再启动电加热器!!!1.6安全●电加热器的维护和保养工作必须在断电的情况下才能进行。
WDDQ-380-400-Ex电加热器使用说明书
防爆电加热器使用说明书一、技术参数:1.产品型号:WDDQ-380-400-Ex2.总外形尺寸:总高度约5300mm直径700mm3.型式:管式电加热:采用Φ30直型电加热管。
展开长度:4350mm;发热区长度:约3900mm;非发热区长度:450mm。
用螺母压紧紫铜垫片密封,方便拆卸。
4.设计压力:4.5MPa最高工作压力:4.05MPa5.设计温度:270℃工作温度:210℃6.加热介质:CO27.工作电压:380V,50Hz,8.工作功率:9.5KW/支9.发热元件:高温镍铬合金电阻丝10.电热管材质:SUS30411.法兰材质:SUS30403不锈钢12.接线腔室:防爆型材质:Q23513.接线方式:△三角型接法(分四组,第一、三组是120KW,第二、四组是80KW)14.防爆等级:dIIBT215.防护等级:IP65,绝缘等级:B16.测温元件:PT100,量程:-50~400℃二、工作流程:加热器发热部分完全浸入在被加热介质里,通电后电热管内的电阻丝就会产生热量并散发到电热管表面,将热量传导给介质。
从而使介质获得满足工艺要求的温度。
三、安装、使用说明1.电加热管设备安装使用前应贮藏在通风干燥处,不得受潮。
2.安装工作环境:-20℃~+40℃,无灰尘、无污染、无腐蚀性气体场所。
3.通电运行前,认真检查电加热管与之配套的电气、仪表、温控系统各设备间线路接线是否连接完好,各接线是否紧固牢靠,内外壳应有效接地。
4.检测电加热管的绝缘电阻,确认合格后方可使用。
5.电加热管安装完毕后,请在气体流通的情况下再通电加热,检查压力及流量,观察内部温度升高情况,在无压力无流通时通电加热极易烧毁电加热管,此类情况生产方不予质保或退换!6.加热器运行前,必须检查电加热器内部气体是否流通,确认无误方可投入使用。
7.电加热管工作时,电压不得超过其额定值的1.1倍。
8.设备初运行时,必须有专人定时观察设备、电气、仪表及控制系统工作是否正常,如发现有异常,应立即停止设备运行。
信辉源8Kw电磁加热器说明书
产品名称深圳信辉源8Kw电磁加热器产品用途:工业大功率加热节能设备适用负载范围:加热含磁性金属材料线圈接出端软开关控制指示灯变压器输出变压器输入电源C相电源B相电源A相电风扇电路板接线端子图示(电路更新与现货为准)一、产品电气规格1、额定电压频率:AC 380V / 50Hz2、电压适应范围:350V~450V3、额定功率:5KW-8KW- (12A×220V×3)4、采用方案:硬锁相半桥串联谐振方案5、电磁感应线圈规格:≥6平方毫米(工业用10平方毫米)6、负载匹配电感量:5KW 240±5UH8KW195±5UH 线圈高度1.0-1.5(平盘式)。
28-30M 线圈高2.0-2.5(缠绕式)二、环境适应能力1、温度:-20℃~60℃;2、湿度:≤95%三、基本性能概述1、电压与功率特性:350~420V恒定功率输出;2、热效率≥90%;3、IGBT正常工作温升:△F≤15℃(过热保护温度:95℃);4、工作频率:16-22KHz;5、半桥式串联谐振;6、具有软启动加热/停止模式;7、具有加热线圈短路保护功能;8、具有多个线圈叠加功率达120KW以上工作而互不干扰;9、可连机工作;四、运行工作操作方法:1:按上图加热器的外接端口图示正确连接好2:通电检查加热器待机是否正常,此时电源指示灯(红灯)长亮,风扇不转,机器处在待机状态。
3:软开关线接到带有隔离的温度控制器上,当温控器处在接通加热状态时加热器即开始运行加热工作,数码管显示8:00,工作批示灯亮.此时留意加热情况是否正常(正常输入电流为38A)。
并未听到异常的声音。
4:机器工作一定时间后等料管或炮筒发热到350度以上后输入电流备有下降,一般都在10A 到12A每相左右。
个别高温区可能降到10A左右,用功能键查询工作频率大概为16Khz-18Khz此属正常现象。
如加热料管到450度后工作电流在10A以下或查询工作频率小于14Khz时可以判断缠绕感应加热线圈电感量略偏大.但不会影响机器基本加热工作5:如有需要设置工作输出功率大小时可按功能键进入设置功率大小,.如软开关处于接通加热工作中可随时按开关键停止或加热工作.五、故障排除:1、有按要求正确接线上,开通电源而无任何显示,加热器不通电时解决方法如下:(1)用测电压器测试输入各相电源电压是否正常,(2)确定输入电源跟变压器没接错和未损坏(3)测试供芯片工作电源是否正常2、待机正常但软开关接通并未正常加热工作:(1)无故障灯亮无故障智能报误码:确认软开关连接温控器线路有没接触不良;(2 ) 冷机显示E3 确认电磁线圈电感量偏大已超出可基本工作范围.测试电感量方法:数字电桥按电感参数1KHZ频率串联模式在冷机情况下直接测试(注意其它同料管的机器禁止工作中测试)。
-电加热蒸汽发生器使用说明书
电加热蒸汽发生器使用说明书―、结构简介蒸汽发生器是一种单锅筒式电加热蒸汽发生器,在锅筒内布置了加热管,经改进后外接水位电极控制,外部用保温材料保温后,再用钢板喷漆的外壳罩住,外观整洁而又漂亮。
用户购回,接上电源和水源后即可使用。
蒸汽发生器设有可靠的水位控制、压力控制等连锁控制装置。
加热管设置在炉体的下部,蒸汽发生器可完全吸收电能,蒸汽发生器环保节能,结构紧凑合理。
按TSGG0001-2012《锅炉安全技术监察规程》1.3(1)条对不适用锅炉的定义,设计正常水位水容积小于30L的蒸汽蒸汽发生器,不属于《锅炉压力容器制造监督管理办法》规定的产品安全性能强制监督检验的范畴,所以可免去地方监督检验。
二、性能特点此型蒸汽发生器具有以下优点:1、合理的设计结构,可有利于安装、操作、节能。
2、壳体采用优质钢材,强度高、耐腐蚀。
3、采用高压旋涡泵,供水时间短、经久耐用。
4、加热时间短,可连续产生蒸汽。
5、结构紧凑、简易、材料耗用少。
6、快装出厂到使用现场后,只需要安装管道、仪表、阀门等附件,即可运行。
7、安装移动方便,只需客户提供合理的蒸汽发生器位置即可。
8、可供应蒸汽冲开水,又可以用于采暖。
三、应用领域服装洗涤熨烫行业:干洗机、烘干机、水洗机、脱水机、熨平机、熨斗、等设备配套使用;食品机械行业:豆腐机、蒸箱、包装机、涂料设备、封口机、等设备的配套使用包装机械行业:贴标机、套标机配套使用生物化工行业:发酵罐、反应釜、夹层锅、搅拌机、乳化机等设备的配套使用;其他行业:(油田、汽车)蒸汽清洗行业、(宾馆、宿舍、学校、搅拌站)热水供应、(桥梁、铁路)混凝土养护、(休闲美容会所)桑拿洗浴、热交换设备等。
四、出厂配套附件1、蒸汽发生器主机:蒸汽发生器本体、底座。
2、阀门、仪表(见出厂配套清单)3、技术文件:蒸汽发生器总图、电气控制图、安装使用说明书、发货清单各1份,产品质量证明书及保修卡各1份。
在接到技术文件时,检查产品与资料是否勿合。
杭州杜特过滤器外壳电加热器使用手册
过滤器外壳电加热器使用手册■■■■■■■■■■■【适用机型】﹡5”-10”-20”呼吸器*使用前请务必仔细通读本手册,确保产品的正确使用。
1杭州杜特过滤器有限公司非常感谢您选择本公司过滤器外壳电加热器。
本使用手册是为更深入地使用过滤器外壳电加热器而缩写的。
错误操作会引发意想不到的故障,使用前请务必熟读本使用手册以确保正确使用本系列产品。
安全注意事项在仔细阅读本使用手册及附属资料并能正确使用前,请不要安装、操作、维护或检查过滤器外壳电加热器。
请在熟悉机器的知识、安全信息以及全部有关注意事项以后再使用。
在本使用手册中,将安全注意事项的等级分为危险和注意。
危险不正确的操作造成的危险情况,将导致死亡或重伤的发生。
注意不正确的操作造成的危险情况,将导致一般或轻微的伤害或造成物体的硬件损坏。
另外,根据情况的不同,两个等级的注意事项,因为它们对于个人安全都是重要的。
1.防止触电危险⊙当通电或正在运行时,请勿打开控制箱盖板和防水接线插头(座)。
否则会发生触电。
⊙在控制箱盖板或防水接线插头(座)打开的情况下严禁运行机器。
可能引起触电事故。
、⊙接线或检查,请断开电源,确认后方可进行操作。
⊙包括接线或检查在内的工作都应该由专业技术人员进行。
⊙应在主体安装后进行接电源。
⊙请勿用湿手旋钮及操作开关,否则会发生触电。
⊙对于电缆,请不要损伤它,对它加上过重的应力,使它承载重物或对它钳压。
否则会发生触电。
22.搬运和安装注意⊙搬运时请保持设备原形,硬压可能导致设备损坏。
⊙搬运时请不要使设备跌落,或受到强烈冲击。
⊙请将设备安装或水平放置,防止设备滑落。
⊙安装前,请检查设备是否有破损。
如发现异常,请联系厂家。
⊙安装前,请检查设备外接线是否脱落。
如发现异常,请联系厂家。
⊙安装时应该按照使用说明书的说明。
、⊙请勿放置在可燃物品附近。
否则可能引发火灾。
⊙请勿使金属片等异物侵入。
否则可能引发火灾。
3.接线注意⊙请正确连接控制箱与加热套的接线。
电气风管加热器规格和安装说明说明书
READ AND SAVE THESE INSTALLATION INSTRUCTIONSflow switch (PDN or PDA) or electronic air flow switch sensors (EAS) and automatic thermal cut-out. This may damage heating elements and controls.Important , direction of installation (refer to arrow on name plate) must be respected. Failure to do so will impair proper operation of thermal cut-out and/or cause overheating of solid state relay(s).Caution, Risk of malfunction , Do not proceed with modification or alteration to internal electric connection or component of the electric heater. Any non-authorized modification will void the warranty.!Features:∙ Zero clearance construction ∙ Horizontal or Vertical air flow∙ Standard control panel door with removable hinges ∙ Approved to CSA and UL standards1 Dimensions2 Installation Tips2.1 Air flow condition to avoid:2.2 Minimum clearance to access control panelCaution , Risk of electric shock and burns. A minimum distance of 39’’ (1m) must be maintained between heating section and any opening or access door in the duct. This applies to all types of heaters. If such distance cannot be maintained, a protective guard (C22.2 No.155 section 4.1.8) must be installed to protect personnel from contact to heating elements and bare live parts.3 HandlingWarning, Risk of failure or malfunction . Do not operate electric heater if heating elements have been damaged during transport or handling.✓ Protective packaging must be kept until installation.✓Electric heater must be handled with care, particularly for the Open Coil electric heater.4 Mechanical installationCaution, Risk of damage and malfunction, Do not block air flow to heating elements, insufficient airflow may damage heating elements and controls.Important , direction of installation (refer to arrow on name plate) must be respected. Failure to do so will impair proper operation of thermal cut-out and/or cause overheating of solid state relay(s),!!!5 Electrical InstallationDANGER: Risk of electric shock. Disconnect all supplies before working on any circuit.CAUTION: Risk of malfunction. Use only copper wires suitable for 221˚F (105˚C).CAUTION: Electric installation must be done by a qualified electrician and must conform to local electrical codes.CAUTION: If a disconnect switch and/or fuses have not been supplied on the control panel of the electric heater, disconnect switch and/or fuses must be installed on supply.CAUTION: Gauge of electric supply wires must be of appropriate section, function of line current, as per local electrical codes.5.1 Power supply wiringSee the name plate for information on voltage and current.✓Connect all wires to appropriate terminals as per the electrical diagram affixed inside the control panel door.✓Correct connection tightening must be verified before start up, and after a short period of operation (typically after 2 weeks).5.2 Typical electric diagram & legendThermal cut-outautomatic reset or Air flow switchor EAS**Single phase power supplyterminalsThermal cut-out Manual reset Disconnect switch3 phases power supplyterminalsNormally opencontactFuseGround terminal Normally closedcontactHeating element InterlockContactor coil TransformerControl circuit supply Back-up safetycontactor coilPneumatic electricswitch (ON/OFF)CommonPilot lightPneumatic electriccontroller(modulating)Solid State Relay inputterminalSolid State Relay outputterminal**Note: Electronic air flow sensor (EAS) is available/installed for heaters less than 50A and dimensions less than 48”x40”. Some restriction may apply.I5.3 Control signal selection and connection5.3.1 Electric ON/OFF signalConnect the contact demand wires to terminals com & 1, 2, 3, etc…of the electric heater.Information about mechanical Air flow switch (PDN or PDA)Upon application of 0.05’’w.c. (12Pa) minimum pressure, mechanical airflow switch will activate internal normally open and normally closed contact.Install pitot tube into the air duct up flow of electric heater. Make sure that the arrow is in the direction of air flow.5.3.2 Pneumatic ON/OFF signalConnect a ØInformation about Pneumatic electric switch (PSO or PSC)Upon application of demand pressure, pneumatic switchwill activate internal normally open (PSO) or normally closed (PSC) contact.Set point is adjustable from 2 to 20PSI (14 to 138kPa)5.3.3 Electrical modulating signal, 0-10 or 2-10Vdc or 4-20mAInformation about Neptronic ®electronic controller (HEC)Neptronic® electronic controller (HEC) is a universal controller accepting any input signal used in the HVAC industry and converting it to a modulating and/or ON/OFF control signal to solid state relay(s) and contactor(s).If the electric heater is equipped with only one modulating stage, part number is HEC0000; and if the electric heater is equippedPneumatic signal inlet port5.3.4 Electric digital signal, AC or DCInformation about Neptronic ®electronic controller (HEC)If the electric heater is equipped with only one modulating stage, part number is HEC0000; and if the electric heater is equipped5.3.5 Electric Neptronic ® signal, resistiveConnect the control signal demand wires to terminals A17 & A18 of the electric heater.Internal set point option:Temperature set point is adjustable directly on the electric heater, preventing over adjustment by user. If the electric heater is equipped with only one modulating stage, part number of electronic controller is HEC0000; and if the5.3.6 Pneumatic modulating signal, 0-15 PSIConnect the tube of the pneumatic signal to the port high pressure and leave the other port free.Information about pneumatic electric controller (PCD or PCR)Upon a pneumatic signal from 0-15 PSI (0 to 103kPa); and a minimum differential of 4 PSI (27kPa), pneumatic electric controller will send a 0 to 10Vdc electric signal to HEC. Direct (PCD) or reverse (PCR) acting preset at factory.Part number of the Neptronic® electronic controller when used with pneumatic electric controller is HEC1000.Pressure input (+)6 Operation conditionAir Flow :Air flow must not be lower than the minimum air flow indicated on name plate.Air flow going through the electric heater must be free of combustible particle, flammable vapour or gas.Open Coil: Air flow going through the electric heater must be free of dust.Zero clearance construction:Neptronic electric heaters are designed and approved for zero clearance to combustible material. Insulation material may be installed directly onto electric heater surfaces or onto air duct. However control panel must be accessible for maintenance.Warning, Risk of fire and/or malfunction, Do not install insulation directly on heating elements.7 MaintenanceNeptronic® electric heater does not require specific maintenance; however, we recommend a yearly inspection, typically before winter season or after a long term shut down.1)Visual inspectionRisk of electric shock. Disconnect all supplies before any visual inspection.✓Verify good condition of heating element.Heating element must be clean, free of dust or lint.✓Open Coil: Verify carefully that there is no dust accumulation. Any dust of lint accumulation can lead to fire hazard.✓Verify any indication of overheating condition (discoloration) as well as any trace of oxidation (rust).2)Electrical inspectionRisk of electric shock. Disconnect all supplies before any electrical inspection.✓Verify correct electrical connection tightening.✓Verify the good condition of fuses (if any).✓Verify resistance of each circuit against ground.✓Verify correct operation of contactor(s).If necessary, electrical component must be replaced only with identical original component.8 Quick Troubleshooting GuideRisk of electric shock. Disconnect all supplies before any electrical inspection and troubleshooting.Any service and troubleshooting must be done by a qualified electrician.Symptom: Electric heater does not react to heating demand.Troubleshooting stepsStep 3Control signal selection jumpersStep 6TPM GreenLEDOutput terminals to heatingstages contactorsStep 7Output terminals to SSR(s)Step 5Input terminals from electronic airflowsensors9 Technical SupportFor any questions or specific requests, please consult our website: Or call: 1 800 361-2308, and ask for the Electric Heater Department.or (514) 333-1433Fax : (514) 333-3163。
柴暖加热器开关说明书
柴暖加热器开关说明书一、安全须知1.请确保本机已安装正确,且电源线插头是正确的规格。
2.请确保安装地面是牢固平整的,以防设备倾倒。
3.请确保设备远离易燃材料,如纸张、液体等。
4.请勿在加热器附近堆放物品,以确保空气流通。
5.使用时,请保持加热器周围通风良好,避免局部氧气过度消耗。
6.请勿将孩子和宠物靠近加热器,以防烫伤或其他安全事故。
7.请勿在加热器表面放置其他物品,以确保正常散热。
二、机器特点1.高能效:采用先进的燃烧技术,燃烧效率高,热量利用率更高。
2.安全可靠:设备具备过热保护和倾倒熄火保护功能,确保使用安全。
3.温控调节:可调节不同温度模式,满足个人需求。
4.一键启动:设备易于操作,一键启动,即可享受温暖。
5.低噪音设计:工作过程中噪音低,不会影响休息和睡眠。
三、开关功能说明1.电源开关(ON/OFF):用于启动或关闭加热器。
当开关处于OFF状态时,设备处于关闭状态;当开关处于ON状态时,设备启动工作。
2.温度调节开关:用于调节设备的加热温度。
根据个人需求,可将温控旋钮调至适合的温度位置。
3.速度调节开关:用于调节设备的送风速度。
根据个人需求,可将速度旋钮调至适合的送风速度位置。
4.定时开关:用于设定操作时间。
设备配有定时功能,可以预设开启和关闭时间,方便自动控制。
5.过热保护:设备具备过热保护功能,当设备温度过高时,自动切断供电,确保安全使用。
四、使用方法1.确认设备已正确安装,插好电源线。
2.打开电源开关(ON/OFF),设备开始工作。
3.按需调节温度和风速,旋转相应的旋钮,直至达到满意的状态。
4.如需定时开关机,请设定好时间,确保在设定时间内自动开启或关闭。
5.设备温度过高或长时间未使用时,会自动触发过热保护,此时设备会自动停止工作,等待冷却后再次启动。
五、维护保养1.使用时请保持设备表面清洁,避免积尘影响散热效果。
2.不使用时,请关闭电源开关(ON/OFF),并拔出电源插头。
3.定期清洁设备内部,去除积尘和杂物,以保持设备正常运行。
飞利浦 3000i系列 室内加热器(对流式电暖器) 使用手册说明书
前壳 散热口
控制面板
后壳 烘衣架
脚板
电源开关 脚轮
2 技术参数
型号
AHR3142CS
额定电源
220V~ 50Hz
额定功率
2000W
防水等级 备注
IPX2 电子式(WIFI款)
本产品已通过3C认证
本产品根据国标:GB4706.1 GB4706.23 制造
3 装箱单
名称 对流式电暖器 遥控器 说明书 脚板 脚轮 壁挂挂钩 膨胀螺钉 壁挂螺钉 脚板螺钉
用。
现象。
• 取暖器在工作时严禁触摸防护网罩, • 本加热器的安装要使得在浴缸内或
防止高温烫伤;请特别注意儿童。
ቤተ መጻሕፍቲ ባይዱ
淋浴区的人不能够触及到开关和其
• 为延长产品使用寿命,请不要在取
他控制器。
暖时移动取暖器。
• 因为加热器被覆盖或不正确的放置 会引起火灾,故不得利用带有可自
禁止覆盖
动接通电源的程序器,定时器或任 警告:为避免过热,禁止覆盖加热器。 何其他装置来使用本加热器。
“中档”控制面板显示2d,按第
三次为“高档”控制面板显示3d, 遥控器使用方法
本机设有三个加热档位,依次循 打开遥控器背部电池盖装上两节 7号电池,
环。
即可使用;遥控器上按“ ”键,加热档位
4. 按“ ”键本机可在1h-12h内 递减一档,按“ ”键,加热
自由定时,每按一次递增1小时, 在显示屏上均有相应的显示,当 控制面板上显示为“ ”时说 明本机连续工作。
固定牢固。
注:壁挂安装时机体不能装上脚;
安装高度最低不能低于150mm。
2
7 使用方法
使用环境温度;也可控制加热器 是否工作;例:按“ ”键将温
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
DRK型空气电加热器DRK Electric Air Heater使用说明书OperatingInstruction Manual江苏国能环保设备有限公司Jiangsu Guoneng Environment Protection Equipment Co., Ltd.一、前言PrefaceDRK型空气电加热器是我厂近年来研制成功的专门供燃煤发电厂除灰系统使用的新型加热设备,该设备由空气电加热器和控制系统两个部分组成。
发热元件采用1Cr18Ni9Ti不锈钢无缝管作保护套管,0Cr27A17MO高温电阻合金丝、结晶氧化镁粉,2经压缩工艺成型,使电加热元件的使用寿命得以保证。
控制部分采用先进的数字电路、集成电路触发器、高反压可控硅等组成可调测温、恒温系统,保证了电加热器的正常运行。
DRK electric air heater, the new type heating equipment special for coal-fired power plant ash collection system, is successfully made by our company recent years. This equipment consists of electric air heater and control system. Heating unit adopts 1Cr18Ni9Ti seamless steel tube as thehigh protective case. After compression craft formation, 0Cr27A17MO2 temperature resistance alloy wire and crystal magnesia powder could make sure the life of electric heating element. Control part uses advanced digital circuit, IC trigger and high counter voltage SCR to compose adjustable thermometer and thermostat system, which insure the normal working of heater.该产品适用于电站空气输送斜槽气化风加热,电除尘器灰斗气化风和贮灰库气化风加热等方面。
This equipment use for power plant air delivery skewed slot gasification wind heating, electric dust collector gasification wind and ash storehouse gasification wind heating. 技术参数 Technical Parameter1.空气电加热器的规格与参数Specifications and Parameter of Electric Air Heater2.控制柜的主要技术指标数据 Main Technical Index Data of Control Box1).输入电压 Input voltage :380V ±5%(三相四线three phase four wiresystem )2).额定功率 Rated capacity :45KW3).额定电流 Rated current :78A(单相single phase)4).控温精度 Control accuracy :0.5级5).控温范围control range :0~300℃三、结构与工作原理Structure and operating principle1.空气电加热器结构 Structure of Electric Air Heater电加热器是由多支管状电热元件、简体、导流板等几部分组成,管状电热元件是在金属管内放入高温电阻丝,在空隙部分紧密地填入具有良好绝缘性和导热性能的结晶氧化镁粉,采用管状电热元件做发热体,具有结构先进热效率高,机械强度好,耐腐、耐磨等特点。
筒体内安装了导流隔板能使空气在流通时受热均匀。
The electric air heater consists of multi tubular heating element, drum, flow deflector and etc. Put the high-temperature resistance wire in the metal tube and tightly fill in the void with crystal magnesia powder, which has the high insulating property and high-thermal conductivity. The tubular heating element is a heating unit with the characteristics of advanced structure, high thermal efficiency, high mechanical strength, corrosion-resistant and wear resistance. Flow deflector, installed in the drum, could make the air uniform heated when circulating.2.控制工作原理 Control principle数显温度控制柜采用数显温度调节仪,集成电路触发器,大功率可控硅和测温元件组成测量、调节、控制回路,在电加热过程中测温元件将空气电加热器出口温度电信号送至数显温度调节仪进行放大、比较后显示测量温度值,同时输出0~10V电压信号到可控硅触发组件的输入端,控制输出脉冲相位,从而控制可控硅导通角度大小,使控制柜有良好的控制精度和调节特性。
利用联锁装置可远距离启动、关闭空气电加热器。
Digital display temperature cabinet uses digital display temperature regulator, IC trigger, high power SCR and temperature element to compose the measuring loop, regulating loop and control loop. Temperature element sends the outlet temperature electrical signal of electric air heater to the digital display temperature regulator, which could indicate temperature value after amplification and comparison. Meanwhile, the digital display temperature regulator outputs the 0~10V voltage signal to incoming end of SCR trigger assembly, in order to control outlet impulse phase. Consequently, making control box being more controllable through control thyristor operating angle,四、安装与使用 Setup and use控制柜应安装在干燥通风、便于操作的地方。
空气电加热器外壳、控制柜外壳应可靠接地、空气电加热器应水平安装,底座螺母要拧紧使其稳固。
本体与外接管道安装时,应注意进出口方向。
安装测温元件时,应区别“+”“-”端接入控制柜接线端子的“+”“-”对应处。
加热器在使用前应测量电源接入端子与金属外壳的冷态绝缘电阻不得低于2M Ω,使用环境相对湿度不大于85%。
电源线的出、入端应牢固可靠,不得松动。
使用前首先检查电源线、测温元件输出联线是否正确,控制柜元器件、螺丝是否松动损坏,如有异常及时拧紧或更换,确认无误后可通电试车。
Cabinet should be installed in the dry ration and handy place. Shell of electric air heater and cabinet could with the connection to the earth. Electric air heater should adopt horizontal installation. Make the base nuts tighten in order to fix heater.1.合上空气开关(QS),电源指示灯亮,数显表控制灯亮并显示所测温度指示值。
Open QS air switch, power indicator light illuminates digital display control light illuminates and indicates the temperature value.2.温度的设定temperature setting:1).温度控制仪面板示意图diagram of temperature regulator panel:显示器indicator;XMT数显温度调节仪:XMT digital display temperature regulator;设定电位器:set potentiometer;指示灯:indicator light;切换开关:switch2).温度预置方法 Temperature initialization:将“切换开关K”拨向右边“控制”,旋转“设定电位器W1”,当顺时针旋转时,温度设定值T设增大,反之减小。
温度预置完毕,再将“切换开关K”拨至中间“测温”,此时显示测温值,即T实。
当T实<T设时,控制指示灯亮,当T实>T设时,指示灯灭。
Move K switch to right “control ” position and spin set potentiometer W 1, when clockwise rotation, temperature setting value T set would grow,otherwise would reduce. After temperature initialization, moving K switch to “thermometer ” position, at this moment indicates the thermometer value T actual.When T actual <T set , control indicator light illuminates, otherwise controlindicator light off.3).报警设定方法 alarm setting :将“切换开关K ”拨向左边“报警”,旋转“设定电位W 2”,当数值达到T设预置完毕,再将K 拨至中间“测温处”。