DPT-2W3(VD)说明书(6U)
新蒂尔电子有限公司产品说明书
508BCURRENT LOOP INDICATOR Operator’s ManualNEWPORT Electronics, Inc.®CountersFrequency Meters PID Controllers Clock/Timers Printers Process Meters On/Off ControllersRecorders Relative Humidity Transmitters Thermocouples ThermistorsWireRate Meters Timers TotalizersStrain Gauge MetersVoltmeters MultimetersSoldering Iron TesterspH pens pH Controllers pH ElectrodesRTDs Thermowells Flow SensorsNEWPORT Electronics, Inc.®For Immediate AssistanceIn the U.S.A. and Canada: 1-800-NEWPORT®In Mexico: (95) 800-NEWPORT SMOr call your local NEWPORT Office.Internet e-mail ******************Additional products fromNEWPORTnet SMOn-Line ServiceIt is the policy of NEWPORT to comply with all worldwide safety and EMC/EMI regulations that apply.NEWPORT is constantly pursuing certification of its products to the European New Approach Directives. NEWPORT will add the CE mark to every appropriate device upon certification.The information contained in this document is believed to be correct but NEWPORT Electronics, Inc.accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.WARNING:These products are not designed for use in, and should not be used for, patient connected applications.This device is marked with the international caution symbol. It is important to read the Setup Guide before installing or commissioning this device as it contains important information relating to safety and EMC.TABLE OF CONTENTS1.0DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.1Definition/Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.2Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.0SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22.1Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22.2Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32.3Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32.4Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32.5Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32.6Mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43.0MECHANICAL ASSEMBLY AND INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43.1Safety Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43.2Intrinsic Safety Parameters for FM(FACTORY MUTUAL) . . . . . . . . . . . . . . . . . .43.4Mechanical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53.5Standard Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64.0SIGNAL INPUT CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104.1508B-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104.2508B-2 and 508B-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .105.0CONFIGURATION AND CALIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115.1Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115.2Calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125.3Alternate FS Calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .135.4FS Procedure Implementation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .135.5Component Access/Unit Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145.6Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166.0 INTRINSIC SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18FiguresPage Figure 1-1 Model 508B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Figure 3-1 Basic Mounting Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Figure 3-2 Surface and TR2/2TK Relay Track Mounting (Option MAT1) . . . . . . . . . . . . .7 Figure 3-3 DIN Track Mounting (Option MDT1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Figure 3-4. External Explosion-Proof Housing Mounting (Option MXS1) . . . . . . . . . . . .8 Figure 3-5. External Explosion-Proof Housing Mounting (Option MXS2) . . . . . . . . . . . .9 Figure 3-6. External Explosion-Proof Housing Mounting (Option EPW2) . . . . . . . . . . . .9 Figure 4-1 508B-1 Signal Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Figure 4-2 508B-2 & 508B-3 Signal Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Figure 5-1. 508B-2 and 508B-3 Case Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Figure 5-2. Calibration Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Figure 5-3. Label Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Figure 5-4. Jumper Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Figure 6-1 Block Diagram for 508B Usage for Factory Mutual . . . . . . . . . . . . . . . . . . .19TablesTable 5-1. Configuration Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .171.0DESCRIPTIONFigure 1-1. Model 508B1.1DEFINITION/APPLICATIONModel 508B is a signal powered, two-wire current-loop indicator that accepts 1-5 mA,4–20mA, or 10-50 mA process signals and digitally display (±2000 active counts) the process variable in either percent or in engineering units for such parameters as pressure, flow,temperature, and level.1.2FEATURESIn-field ProgrammabilityInput ranges (1-5 mA, 4-20 mA, or 10-50 mA) are selected by push-on jumpers. Three decimal points and a dummy right-hand zero may also be selected by push-on jumpers. Zero and span may be fine tuned with precision, 25-turn potentiometers. Positive slope response may be changed to negative slope response (e.g. , +6000 to –18000) by simply changing two other push-on jumpers.(.078)Signal PoweredModel 508B obtains operating power directly from the current loop, requiring a drop of lessthan 2.5 V or 2.5 mW at 1 mA.Electrical Isolation/Overrange ProtectionThe 508B is electrically isolated from its case and is immune to most sources of electricalnoise encountered in process-control environments. In the event of input overrange currents, the 508B can tolerate 250 mA in the forward direction and 1000 mA reverse.Vibration/Shock/Water ResistanceLow mass and multi-point circuit board support give excellent vibration and shock resistance.Sturdy, die-cast construction, polyurethane paint,and full fluorosilicone gasketing ensure avirtually waterproof case.Circuit boards are conformally coated for added humidity protection.Mounting VersatilityThe 508B-1 may be mounted in a control room on either American or European relay tracks with snaptrack adaptors. The unit can be wall mounted using an available bulkhead adaptor or mounted in an explosion-proof enclosure for wiring compatibility with other equipment in hazardous environments.Both the 508B-2 and the 508B-3 may be connected directly to a conduit with a "T" junction box.2.0SPECIFICATIONS2.1INPUTCurrent:1-5 mA, 4-20 mA, or 10-50 mA(jumper selectable)Voltage drop: 2.5 V max forward; up to 50 mAProtection:250 mA forward at 3 V or 6 V with IS option;1000 mA reverse at 2.5 VZero range:–2510 to +2000 counts; jumper selectable in 4 overlappingcoarse ranges with a 25-turn potentiometer for continuousadjustment within the following selected ranges: –2510 to–1420; –1580 to –420; –470 to +850; and +760 to +2000.Span range:0 to 2000 counts, continuously adjustable with 25-turnpotentiometerNormal mode rejection:46 dB min at 50/60 HzCommon mode rejection:120 db typical, dc to 60 HzCommon mode voltage:700 V peak from dc to 60 Hz (meter to case)RFI susceptibility:Less than ±0.5% of span at a distance of one meter from a2-watt, hand-held transceiver (approximately equivalent to10 V/m field strength) at frequencies of 27 MHz or 440 MHzNOTE: Proper lead dress and shielding required.2.2ACCURACYAccuracy:Within ±0.1% Span ±1 Count at +25°CZero Tempco:±0.1 Count/K typ. , ±0.2 Count/K max.Span Tempco:±0.005% Span/K typ. , ±0.015% Span/K max.2.3DISPLAYType:7-segment LCD, 8.9 mm (0.350 in) highColor:Black digits on white backgroundSymbols:–1.8.8.80Polarity:Minus signOverrange:Three least significant digits blankedExtra digit:Dummy right-hand zero is jumper selectableDecimal points:Three positions, jumper selectableLifetime:More than 30,000 hours to 2:1 contrast ratioTemperature derating:2:1 lifetime reduction for each 10°C above 60°CHumidity derating:2:1 lifetime reduction for each 10%RH above 60%RH2.4CONVERSIONTechnique:Dual-slope, average-value with autozero correctionPolarity:Determined automatically at the end of signal integrationperiodSignal integration period:100 mS typ.Reading rate: 2.5/sec2.5ENVIRONMENTALTemperature:-40 TO +85°CHumidity:To 95% at 40°CVibration: 1.52 mm (.06 in) double amplitude, 10-80 Hz cycledShock55 g, half-sine, 9-13 msec durationWater resistance Watertight to a proof pressure of 35 kPa (5 psi)Mounting position:Any2.6MECHANICALWeight:400 g (14 oz)Diameter:74 mm (2.9 in)Height:48 mm (1.9 in) including barrierElectrical connections:Standard: 3-position barrier strip with #6 screw wire clampsOptional: Two #18 stranded wires, 305 mm (12 in) long3.0MECHANICAL ASSEMBLY AND INSTALLATION3.1SAFETY CONSIDERATIONSTo ensure safe operation follow the guidelines below:VISUAL INSPECTION: Do not attempt to operate the instrument if damage is found.This instrument will meet the requirements of certain FM safety certifications for hazardousenvironments. In order to meet these requirements the appropriate intrinsic safety barrier must be included in the installation to limit the voltage and current that may be introduced in thehazardous environment.EXERCISE CAUTION: Due to certain current loop installations, high common mode voltages may be present on the loop circuits. Become familiar with the possible hazards that your circuit may present before installing this meter or, to be safe, remove all sources of power to thecircuit while installing.RAIN OR MOISTURE: Do not expose the instrument to condensing moisture.3.2INTRINSIC SAFETY PARAMETERS FOR FM(FACTORY MUTUAL)Certificate No. 5X2A0.AXV max=12.5 V,I max=250 mAIntrinsically Safe for Class I, II and III, Division 1, Groups A,B,C,D,E,F and G hazardouslocations.Ci=8.6 µFLi=0 mH3.3MECHANICAL INSTALLATIONRear view: Standard, integral mounting plate508B-1508B-2 and 508B-3Figure 3-1 Basic Mounting Configurations12.7 mm or 1/2 inch conduitThe 508B is packaged in a small, rugged, die-cast, zinc-alloy case designed to fit 3" I.D.or larger housings, requiring less than 2" of height.Three basic 508B configurations (508B-1, 508B-2, and 508B-3) provide mounting versatility.The 508B-1 provides for surface, track, or explosion-proof housing mounting and isconnected with a 3-terminal, #6 screw barrier strip (beneath the display window).The 508B-2 is equipped with a 1/2" EMT conduit fitting on the case side beneath the display.The fitting has two 0.3 millimeter long, #18 stranded insulated wires passing through aneoprene moisture plug for hookup to junction boxes with standard wire nuts.The 508B-3 is equipped with a 1/2" NPT conduit fitting on the case side beneath the display.The fitting has two 0.3 mm long, #18 stranded insulated wires passing through a neoprene moisture plug for hookup to junction boxes with standard wire nuts.3.4STANDARD MOUNTINGTapped holes on the back of the 508B case provide for custom mounting to a flat surface;integral flanges on the back of the case provide for standard 8TK2 relay track mounting.For flat surface mounting, use #6 hardware.For 8TK2 relay track mounting, simply push onto track.The following optional adaptors provide additional mounting options:1.Adapter plate for surface mount with two #8 front-entry screws through keyhole slots or forpush-mount into TR2/2TK relay track. (Option MAT1)2.Rail clamp for push mount onto DIN EN 50 022 relay track. (Option MDT1)3.Spring retainers for mounting in 76.4 to 88.9 mm (3 to 3.5 in) inside diameter explosion-proof housings.(Option MXS1)4.Wire brackets for mounting the 508B above a transmitter in a single housing.(Option MXS2)ADAPTER MOUNTINGRELAY TRACK MOUNTING (FOR TR2/2TK TRACK R.D.I.)Figure 3-2 Surface and TR2/2TK Relay Track Mounting (Option MAT1)1.Position plate for desired application.2.Use #6 hardware to mount plate to the back of the case.Figure 3-3 DIN Track Mounting (Option MDT1)1.Position plate for desired track direction.e #6 flathead screws to mount plate to the back of the case.3.Snap case assembly onto DIN rail.CASESCREW (4 REQ’D)CASEADAPTER PLATESCREW (4 REQ’D)CASEADAPTER PLATESCREW (4 REQ’D)CASESCREW (4 REQ’D)DIN RAIL LATCHDIN RAIL ADAPTERDIN RAIL ADAPTERDIN RAIL LATCHDIN TRACK(DIN EN 50 022)DIN TRACK (DIN EN 50 022)TOP VIEW OF EXPLOSION-PROOF HOUSING.UNIT AND HOUSING SHOWN FOR REFERENCE ONLY .Spring Retainer for Explosion-Proof HousingFigure 3-4. External Explosion-Proof Housing Mounting (Option MXS1)1.Position spring retainers across the back of the case.e wire protector feet (4 provided with Option MXS1) to hold spring retainers in place.3.Press case assembly into explosion-proof housing.CASESCREW (4 REQ’D)1/2” N.P .T.BOTH ENDSBRACKET (2 REQ’D)8 MM HEX (5/16)Figure 3-5. External Explosion-Proof Housing Mounting (Option MXS2)1.Install brackets using #6 screws and flat washers.2.Mount 508B above transmitter as shown in Figure 3-6.3.Press wires to pass into housing.Figure 3-6. External Explosion-Proof Housing Mounting (Option EPW2)CASESCREW (4 REQ’D)WASHERS (4 REQ’D)WIRE BRACKETS (2 REQ’D)508BWIRE BRACKETSTRANSMITTER4.0SIGNAL INPUT CONNECTIONSWARNING: Input currents in excess of protective limits can damage your meter4.1508B-1The 508B-1 has a 3-terminal barrier strip on the front of the case below the display window.The signal inputs are marked with a "+" or a "–" symbol. The third terminal (case ground) is marked with a "/ / / " e of a shielded cable, properly dressed, is recommended.4.2508B-2 and 508B-3Both the 508B-2 and 508B-3 come equipped with a male conduit fitting on the side of the case.The 508B-2 fitting is 1/2" EMT; the 508B-3 fitting is 1/2" NPT. Each conduit fitting is plugged with a rubber stopper. Two 0.3 millimeter long, #18 stranded insulated wires are passed through each stopper.The two wires are white and black. The black wire is the "+"signal input; the white wire is the "–" signal input. Either unit can be hooked up using standard wire nuts.Figure 4-1 508B-1 Signal ConnectionsScrew-Terminal Pin Assignment 1+ SIGNAL INPUT 2– SIGNAL INPUT 3GROUNDFigure 4-2 508B-2 & 508B-3 SignalConnections Terminal Wire Assignment BLACK WIRE + SIGNAL INPUT WHITE WIRE – SIGNAL INPUT5.0CONFIGURATION AND CALIBRATIONThe factory setup (FS) option procedure is to configure the 508B for a specific application.Customers may specify any two current inputs and their corresponding digital readings.For optional configuration procedures, see Section5.3.The unit may be configured using the push-on jumpers already positioned on the pin-forest.Pin-forest designations are illustrated in Figure5-4.5.1GLOSSARYThe following terms and their definitions appear throughout the following procedures: DP1 Decimal point 1.999DP2 Decimal point 19.99DP3 Decimal point 199.9DRHZ Dummy right-hand zeroG Gain expressed in counts per mAI1 Lowest input current in mAI2 Highest input current in mAN1 Reading in displayed counts at input current I1N2 Reading in displayed counts at input current I2RN Required range number for zero range selectionRSS Reverse span slopeZR1 Zero range (-2510 to -1420)ZR2 Zero range (-1580 to -420)ZR3 Zero range (-470 to +850)ZR4 Zero range (+760 to +2000)5.2CALCULATIONNOTE: An alternate FS calculation procedure is given in Section 5.31.Base all calculations on one of three ranges: 1 mA to 5 mA, 4 mA to 20 mA, or 10 mA to50 mA. Write results of calculations in blanks provided below each procedural step.2.Determine the lowest input current, I1, specified by the customer:I1 = _________mA3.Determine the highest input current, I2, specified by the customer:I2 = _________mA4.Determine the reading, N1, at input current, I1, specified by the customer:N1 = _________counts5.Determine the reading, N2, at input current, I2, specified by the customer:N2 = _________counts6.Calculate the gain (G1):G = (N2 - N1) =( - ) counts per mA(I2 -I1) ( - )7.Calculate the required range number:RN = N1 - (I1 x G) =_________NOTE: If G is greater than 500, it is out of the operating range for the standard unit.8.Select the zero range, ZR, that includes the required range number, RN, from thefollowing ranges:ZR1 = -2510 to -1420ZR2 = -1580 to -420ZR3 = -470 to +850ZR4 = +760 to +20009. Proceed to FS Procedure Implementation, Section 5.4.5.3ALTERNATE FS CALCULATION1. (Line 1) Low signal input (mA) =_______________________2. (Line 2) High signal input (mA) =_______________________3. (Line 3) Low signal input reading (counts)_______________________4. (Line 4) High signal input reading (counts) =_______________________5. (Line 5) Line 2 - Line 1 =_______________________6. (Line 6) Line 4 - Line 3 =_______________________7. (Line 7) Line 6 divided by Line 5 =_______________________8. (Line 8) Line 7 x Line 1 =_______________________9. (Line 9) Line 3 - Line 8 =_______________________10.Select a zero range from one of the following,where the number on Line 9 falls between thehigh and low numbers of that ZR range:ZR1 = -2510 to -1420ZR2 = -1580 to -420ZR3 = -470 to +850ZR4 = +760 to +200011.Proceed to FS Procedure Implementation, Section 5.4.5.4FS PROCEDURE IMPLEMENTATIONPin-forest designations are illustrated in Figure 5-4Jumper Locations. Range and displayselection are listed in Table 5-1Configuration Chart.1.If the current range chosen in either Section 5.2Step 1 or Section5.3Steps 1 and 2equals either 4 mA to 20 mA or 10 mA to 50 mA, install a push-on jumper as indicated inTable5-1.2. If N1 (5.2Step 3 or 5.3Step 3) is more positive than N2 (5.2Step 5 or 5.3Step 4),reverse the span slope (RSS) by installing two push-on jumpers as indicated inTable5-1.3. Select the zero range required (ZR1, ZR2, ZR3, or ZR4), and install a push-on jumper asindicated in Table5-1.4. If a dummy right-hand zero (DRHZ) is required, install a push-on jumper as indicated inTable5-1.5. If a decimal point is required (DP1, DP2, DP3), install a push-on jumper as indicated inTable5-1.5.5COMPONENT ACCESS/UNIT CALIBRATIONTools and Equipment#2 Phillips screwdriverJewelers' slotted screwdriverPrecision milliampere power sourceor10 V power supply, 4 1/2 digit DMM with milliampere range and 10 kOhm rheostatFigure 5-1. 508B-2 and 508B-3 Case Access420100.000.0mA=mA=INPUTCURRENTDISPLAYREADINGFigure 5-2. Calibration Setup1.Remove 4 Phillips-head screws from the top of the 508B case, and lift main unit fromcase. (See Figure 5-1)2.Select the desired jumper configuration and install push-on jumpers in locations indicatedin the Table 5-1Configuration Chart. (See Figure 5-4)3.Pull off two sealing plugs that cover 508B span and zero potentiometer screw heads.4.Set up 508B in calibration configuration. (See Figure 5-2)NOTE:Store unused jumpers in a vertical position on unused upper pins closest to thedisplay board.5.Calibrate unit as follows:A.Alternately apply input currents I1 and I2, and adjust span pot (S) until span reading equals N 2- N 1counts.B.Apply input current, I1, and adjust the zero pot (Z) until a reading equal to N1 is displayed.6.Remove 508B from calibration setup.7.Replace two sealing plugs over 508B span and zero potentiometer screw heads.8. Apply labels as described in Section 5.6. (See Figure 5-3).9.Replace 508B main unit in case.10. Replace 4 Phillips-head screws that hold the 508B unit to the case.5.6LABELSFigure 5-3. Label Placement1. Add new label directly over existing label. Add correct values of I1, I2, N1, and N2.2. Install one label on the outside of the housing as shown above.3. Install one label on the wire shield as shown above.420100.000.0mA =mA =INPUT CURRENT DISPLAYREADINGFigure 5-4. Jumper LocationsTable 5-1. Configuration ChartConfiguration Push-On Jumpers1-5 mA NONE4-20 mA J*10-50 mA ANormal span slope G,a*Reverse span slope F,ZZero range -2510 to -1420 (ZR1) IZero range -1580 to -420 (ZR2) TZero range -470 to +850 (ZR3) NONEZero range +760 to +2000 (ZR4) cDummy right-hand zero (DRHZ) DDecimal Point 1.999 (DP1) WDecimal Point 19.99 (DP2) VDecimal Point 199.9 (DP3) L** Default SettingNOTE: The factory-calibrated configuration shows 00.0 to 100.0 for a 4 to 20 mA input.6.0 INTRINSIC SAFETY CONSIDERATIONSFigure 6-1 Block Diagram for 508B Usage for Factory MutualNOTES:1.Apparatus which is unspecified except that it must not be supplied from nor containunder normal or abnormal conditions a source of potential with respect to Earth inexcess of 250V R.M.S. or250V D.C.2.The following output parameters apply; Vmax=12.5V, Imax=250mA, Ci=6.2uF,Li=0.3.The Interconnecting Cable may be a twin pair, or a pair contained in a Type A orType B multicore cable (as defined in EN50 039 clause 5.3) provided that the peakvoltage of any circuit contained within the multicore does not exceed 60 Volts.4.The capacitance or inductance or inductance to resistance (4R) ratio of theInterconnecting Cable must not exceed the values specified for the barrier in use.5The electrical circuit in the Hazardous Area must be capable of withstanding without breakdown an A.C. test voltage of 500V R.M.S. to Earth or frame for oneminute.For immediate technical or application assistance please call:Newport Electronics, Inc.2229 South Yale Street • Santa Ana, CA • 92704 • U.S.A.TEL: (714) 540-4914 • FAX: (203) 968-7311TollFree:1-800-639-7678••e-mail:******************ISO 9001 CertifiedNewport Technologies, Inc.976 Bergar • Laval (Quebec) • H7L 5A1 • CanadaTEL: (514) 335-3183 • FAX: (514) 856-6886TollFree:1-800-639-7678•www.newport.ca•e-mail:***************Newport Electronics, Ltd.One Omega Drive • River Bend Technology CentreNorthbank, Irlam • Manchester M44 5BD • United KingdomTel: +44 161 777 6611 • FAX: +44 161 777 6622TollFree:0800488488••e-mail:******************.ukNewport Electronics B.V.Postbus 8034 • 1180 LA Amstelveen • The NetherlandsTEL: +31 20 3472121 • FAX: +31 20 6434643TollFree:08000993344•www.newport.nl•e-mail:***************Newport Electronics spol s.r.o.Frystatska 184, 733 01 Karviná • Czech RepublicTEL: +420 59 6311899 • FAX: +420 59 6311114TollFree:0800-1-66342•www.newport.cz•e-mail:***************Newport Electronics GmbHDaimlerstrasse 26 • D-75392 Deckenpfronn • GermanyTEL: 49 7056 9398-0 • FAX: 49 7056 9398-29TollFree:0800/6397678•www.newport.de•e-mail:****************Newport Electronique S.A.R.L.11, rue Jacques Cartier • 78280 Guyancourt • FranceTEL: +33 1 61 37 29 00 • FAX: +33 1 30 57 54 27TollFree:0800466342•www.newport.fr•e-mail:****************Mexico and Latin AmericaFAX: 001 (203) 359-7807En Español: 001 (203) 359-7803。
施耐德万高D型控制器使用说明-
3
常用和备用脱扣仅应用于CB级产品
52
34
1
故障记录 故障值
3
A/V
53
35
1
合闸位置
0x0001 常用合闸
0x0002 备用合闸
0x0004 双份位置
3
WTS-D800~5000系列没有双分位置
54
36
1
转换延时(0~255S)
3,6
秒
55
37
1
返回延时(0~255S)
3,6
秒
56
2E
1
故障记录 年
3
年
47
2F
1
故障记录 月
3
月
48
30
1
故障记录 日
3
日
49
31
1
故障记录 时
3
时
50
32
1
故障记录 分
3
分
51
33
1
故障记录 故障类型
0x0001常用欠压
0x0002常用过压
0x0003常用断相
0x0004常用脱扣
0x0005备用欠压
0x0006备用过压
0x0007备用断相
0x0008备用脱扣
BIT0=1 --常用过压
高字节未用
3
--
44
2C
1
故障标志2
BIT7 --空
BIT6 --空
BIT5 --空
BIT4=1 --备用合闸
BIT3=1 --常用合闸
BIT2=1 --故障锁定
BIT1=1 --备用脱扣
BIT0=1 --常用脱扣
3
DPT-2W3(VD)说明书(6U)
DPT-2W3分布式微机变压器综合保护装置_________________________________________技术和使用说明书南京恒星自动化设备有限公司SUN NANJING AUTOMATION EQUIPMENT CO.,LTD南京恒星自动化设备有限公司版权所有2005.04(V1.0)本说明书适用于DPT-2W3保护装置,V1.00版本本说明书和产品今后可能会有小的改动,请核对实际产品与说明书的版本是否相符。
目录1.概述 (4)1.1 DP系列产品概述 (4)1.2 应用范围 (4)1.3 保护配置 (4)1.4性能特征 (5)1.5规范性引用文件 (5)2.技术条件 (6)2.1环境条件 (6)2.2电源 (7)2.3 交流回路 (7)2.4过载能力 (7)2.5装置的主要功能 (8)2.6主要技术性能指标 (8)2.7测量元件 (10)3.工作原理 (10)3.1.差动电流与制动电流 (10)3.2. 差动速断继电器: (12)3.3. 比例差动继电器 (12)3.4. 定时限过流保护 (13)3.5. 功率继电器 (13)3.6. 零序过压继电器 (14)3.7. 过励磁继电器 (14)3.8. 过负荷继电器 (15)3.9.过温及瓦斯继电器 (15)3.10 主要逻辑回路 (15)4.辅助功能 (16)4.1定值组切换 (16)4.2 测量 (16)4.3 对开关的控制 (17)4.4 事故记录 (17)4.5 故障录波 (17)4.6 事件记录 (17)5.面板及操作 (18)5.1面板说明 (18)5.1.1面板图 (18)5.1.2面板按键说明 (18)5.1.3指示灯说明 (19)5.1.4操作箱的使用 (19)5.2键盘操作 (19)5.3界面内容 (19)5.3.1默认界面 (19)5.3.2目录界面 (19)5.3.3监测界面 (20)5.3.4系统界面 (20)5.3.5控制界面 (20)5.3.6整定界面 (20)5.3.7设置界面 (20)5.3.8记录界面 (21)5.3.9校准界面及调试界面 (21)5.3.10重要数据浏览界面 (21)6. 安装与对外接线 (21)6.1 开箱与安装 (21)6.1.1 开箱和包装 (21)6.1.2 安装现场要求 (21)6.1.3 安装尺寸 (22)6.1.4 保护和系统接地 (22)6.2 连接 (24)6.2.1 连接测量和辅助回路 (24)6.2.2 连接电源 (24)6.2.3 连接开关量输入 (24)6.2.4 连接通讯口1 (24)6.2.5 连接亮屏控制 (24)6.2.6 面板LED平面发光管的使用 (25)附录一.信息表 (26)附录二.DPT-2W3保护装置逻辑框图 (39)附录三.DPT-2W3保护装置开出原理图 (39)附录四.DPT-2W3保护装置对外接线原理图 (39)DPT-2W3型分布式微机变压器综合保护装置1.概述1.1 DP系列产品概述DP系列的保护在开发时借鉴了当前国内外同类产品的成熟经验,并根据我国电力系统运行的实际要求,以及数字式保护今后的发展趋势,在制定设计方案时要求做到:●满足变电站综合自动化的要求,有按标准规约制定的网络接口,所有保护的运行数据能够在数据总线上交流,配合监控软件可以组成变电站自动化系统。
Panduit UP003LSM高可靠电力供应设备详细说明书
UPS003LSMPA27224A01 Rev: 02 3-2014UNINTERRUPTIBLE POWER SUPPLY LOAD SENSE MODULEOPERATION MANUAL© Panduit Corp. 2014Original InstructionsTO REDUCE THE RISK OF INJURY, USER MUST READ INSTRUCTION MANUALEmail:***********************EU Website:/emeaEU Email:emeatoolservicecenter@Technical Support:Tel: 1-888-506-5400, ext. 83255Panduit Europe • EMEA Service CenterAlmelo, NetherlandsTel: +31-546-580-452 • Fax: +31-546-580-441TABLE OF CONTENTSUPS LSM GENERAL SPECIFICATIONS (2)Model Number (2)Input Power (2)Output Power (2)Environmental (2)Compliance (2)Installation (2)Performance (3)PRECAUTIONS AND GENERAL GUIDELINES (3)Safety Warnings (3)Electrical Safety Practices (4)Personal Safety (4)Service (5)1.INTRODUCTION (5)1.1. BACKGROUND (5)1.2. PURPOSE (5)1.3. TERMS AND ABBREVIATIONS (5)1.4. INSTALLATION (6)TABLE OF FIGURESFigure 1: DIN Rail Installation (6)Figure 2: System Block Diagram (6)Figure 3: Load Sense Module (7)Supply Load Sense Module) may also be referred to as “UPS LSM”.UPS LSM GENERAL SPECIFICATIONSModel NumberUPS003LSMInput PowerVoltage: 30.0 VDC MAXCurrent: 5 A MAXOutput PowerVoltage: 30.0 VDC MAXSense: 100 mV MAXCurrent: 5 A MAXEnvironmentalOperating Temperature: -40 to +60°C.Storage (non-operational) Temperature: -40 to +70°C.Humidity: 0 to 95% RH, noncondensingOperational Vibration: 2G at 10 to 500 HzOperational Shock: 20G (11ms 3 bumps / direction, 18 bumps in total)Complianceo UL 1778 and CSA C22.2 No. 107.3-05 “Uninterruptible Power Supply Equipment”o UL 508 and CSA-C22.2 No. 14 “Industrial Control Equipment”o UL 60950-1, 2nd ed, 2011-12-19, CSA C22.2 No. 60950-1-07, 2nd ed, 2011-12"Information Technology Equipment - Safety - Part 1: General Requirements"o (Low-Voltage Directive*) IEC 60950-1:2005+AM 2009, EN 60950-1:2006+A1:2010+A11:2009+A12:2011 "Information Technology Equipment -Safety - Part 1: General Requirements"o ISA 12.12.01:2013, CSA C22.2 No. 213-1987M (R2013) “Standard For Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified)Locations”o FCC Title 47 CFR 15 Subpart B Emissions Class Ao RoHS All materials and components used must meet the material restrictions of European Directive 2002/95/EC on the Restriction of Hazardous Substanceso CAN ICES-3(A)/NMB-3(A), ICES-003 Issue 5o IP20 per IEC 60529o IEC Ex (pending)Voltage / Current / Temp /OutputConformancesApprovalsInstallationTop hat (DIN) rail EN 50022Width: 22.6mm (0.89 in)Depth: 113.3mm (4.46 in)Height: 111.5mm (4.39 in)Weight: 105.7g max (0.233 lbs, max.)Terminals: screw type, accepts #12 to #18 AWG, stranded/solid/terminated The device shall have control wiring along the top edge.PerformanceVoltage Drop: 100 mV maximum at 5 AP R E C A U T IO N S A N D G E N E R A L G U ID E L IN E SThe basic condition for safe use and proper operation of the UPS LSM is the knowledge and attention to the safety information provided in this manual.The following safety information must be observed by all persons who will work with the UPS LSM.All rules and instructions for the work place must be observed, especially those for prevention of accidents.This symbol is used to call your attention to hazards or unsafe practices which could result in an injury or property damage. The signal word, defined below, indicates the severity of the hazard. The message after the signal word provides information for preventing or avoiding the hazard.WARNING Hazards which, if not avoided, COULD result in severe injury or death.CAUTIONHazards or unsafe practices which, if not avoided, MAY result in injury or property damage.Safety WarningsWARNING• Read all safety warning and all instructions. Failure to follow the warningsand instructions may result in electric shock, fire and/or serious injury. • Save all warnings and instructions for future reference.Panduit Corp. recommends the UPS LSM be used with all installed safety features. Customerassumes all liability for injury that could result from improper use of this UPS LSM andresponsibility for all necessary training to ensure safe operation of this UPS LSM. • FOR INSTALLATION AND USE BY TRAINED PERSONNEL ONLY.• IF ANY DAMAGE TO THE PRODUCT IS APPARENT OR SUSPECTED, DO NOT USE THE PRODUCT. REFER PRODUCT TO QUALIFIED SERVICE PERSONNEL.• FCC WARNING: CHANGES OR MODIFICATIONS TO THE PRODUCT COULD VOID THE USER’S AUTHORITY TO OPERATE THE PRODUCT.•USE RECOMMENDED ACCESSORIES. CONSULT THE OWNER’S MANUAL FORRECOMMENDED ACCESSORIES. THE USE OF IMPROPER ACCESSORIES MAY CAUSE RISK OF INJURY TO PERSONS.Electrical Safety PracticesGROUNDING:In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current which reduces the risk of electrical shock.Improper connection of the equipment grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding conductor.Check with a qualified electrician, or service personnel if the grounding instructions are not completely understood; or if in doubt as to whether the UPS LSM is properly grounded.Avoid body contact with earthed or grounded surfaces, such as pipes, radiators, ranges and refrigerators.There is an increased risk of electric shock if your body is earthed or grounded.WARNINGONLY OPERATE THE UPS LSM IN A CLEAN, DRY, INDOOR ENVIRONMENT.DO NOT EXPOSE THE UPS LSM TO RAIN OR WET CONDITIONS. Water entering a UPS LSM will increase the risk of electric shock.KEEP AWAY FROM LIVE CIRCUITS:•Operating personnel must not remove covers.•Replacement of components and internal adjustments must be made by qualified maintenance personnel.•Disconnect power when replacing components.• Dangerous voltages may exist even with the power removed.• To avoid injuries, always disconnect power and turn power switch to OFF.• Input connection to the product must remain accessible as a disconnect device.• DO NOT work on the product; connect or disconnect cables during periods of lightning.•Provide wiring per national and local electrical codes.Warning : A disconnect switch shall be provided by others for DC input circuit and shall be in accordance with the National Electric Code, ANSI/NFPA 70.Personal SafetyWARNINGUse personal protective equipment. Safety glasses must be worn at all times by all persons installing the UPS LSM.Service•Have your UPS LSM serviced by a qualified repair person using only identical replacement parts.Contact Panduit Tool Service at the following locations:Panduit Tool Solutions Division (USA) 16530 W. 163rd Street Lockport, IL 60441Tel.: 1-888-506-5400, ext. 83255Panduit EMEA Service Center (EUR) EMEA Tool Service Center Bedrijvenpark Twente 360 7602 KL Almelo tel + 31 546 580 451The information contained in this manual is based on our experience to date and is believed to be reliable. It is intended as a Web Interface for use by persons having technical skill at their own discretion and risk. We do not guarantee favorable results or assume any liability in connection with its use. Dimensions contained herein are for reference purposes only. For specific dimensional requirements consult thefactory. This publication is not to be taken as a license to operate under, or a recommendation to infringe any existing patents.1. IN T R O D U C T IO NBACKGROUND1.1.The UPS003LSM is designed for redundant power back-up systems. The UPS003LSM is intended to function only with the Panduit UPS003024024015 (UPS) unit. The UPS is rated for a 24 VDC maximum output rating. The UPS LSM is connected to the main power supply line of 24 VDC. The UPS is connected along the secondary power supply line and is connected to the UPS LSM, which allows the UPS to measure the current power consumption of the system. This increases the accuracy of the estimated UPS potential hold time in the event the UPS is required to supply power.PURPOSE1.2.The purpose of this document is to provide the user with the information necessary to connect the UPS LSM.TERMS AND ABBREVIATIONS1.3. A.................... A mpereDC ................. D irect CurrentPCB ............... P rinted Circuit BoardUPS ............... U ninterruptible Power Supply UPS LSM ....... U PS Load Sense Module V .................... V olts W ................... W attsINSTALLATION1.4.Figure 1: DIN Rail InstallationNo minimum spacing to other modules is required for proper operation of the device.To install the UPS LSM, place the module with the DIN rail guideway on the top edge of the DIN rail and then snap it downwards and shown in Figure 1.To remove, release the snap-on catch using a screwdriver and then detach the module from the bottom edge of the DIN rail as shown in Figure 1.NOTE: A 5A external overcurrent protection device is required to protect the UPS LSM.Wiring DiagramFigure 2: System Block DiagramFigure 3: Load Sense ModulePins 3 and 4 of the load sense module are connected to the sense input terminals of the UPS. Note that pin 3 of the current sense resistor must be connected to the “+” sense terminal and pin 4 of the current sense resistor must be connected to the “-“sense terminal. Note that these connections may not be reversed. These connections allow the UPS to measure the current flow to the load under normal operation so that it can predict the run time when backup poweris being provided by the UPS.。
德尔空调设备说明书
Specification and ManualCustomer:Description: Air Conditioner for EquipmentCustomer Part No.: Rev.:Delta Model No.: HEC0600AFS Rev.: 02Sample Date Code:Sample Issue Date: Sep.02 2020DELTA ELECTRONICS, INC.252, SHANG YING ROAD, KUEI SAN TEL: 886-(0)3-3591968 TAOYUAN CITY 333, TAIWAN FAX: 886-(0)3-3591991Table of content Description (3)Packing & Shipping (3)Safety Notes (3)1.Product Instruction (7)1-1. General Description (7)1-2. Main Feature & Model Number (7)1-3. Dimension (9)1-4. Mounting plane Cutout (10)1-5. Configuration & Maintenance (11)1-6. Thermal and Airflow (13)3.Environmental Condition (17)4.Reliability Table (17)5.Safety Certification (17)6.Accessory (17)7. Parameters (18)7-1 Parametric Setup (18)7.2 Self-Test (19)7.3 Alarm Logs & Fault Processing (19)8.Installation Notice (22)9.Reclaim (22)10.Versions (23)DescriptionThis document is an installation and the characteristics of Delta HEC series. Before installing the unit, please read this manual thoroughly, and following the instructions contained in it. The document is the exclusive property of Delta Electronics, Inc. it should not be distributed, reproduced, or any other format without prior permission of Delta.Specifications are subject to change without notice.Packing & ShippingDuring handling or transport, air conditioner must be kept in upward position, “NOT”inverted, flat, or subject to excessive tilt and collision. The air conditioner is a precision instrument; it should be handled and transported with care. Do not stand on the box, or place heavy objects on top of the box. Pay attention to the below icons on the package.If air conditioner is toppled, slanted or dropped, follow these steps: a. stand unit up for12 hours to ensure refrigerant pressure stability, b. power on the unit and execute self-test to make sure no alarm condition, c. keep the air conditioner running for 1 hour to make sure there is no abnormal acoustic noise.Safety NotesPlease read the safety notes carefully before installing the air conditioner, and be sure to install it correctly. After completing installation, check that the unit operates properly during start-up operation.Meaning of WARNING and CAUTION notices:Warning:Failure to follow these instructions properly may result in personal injury or loss oflife.Caution:Failure to observe these instructions properly may result in property damage or personal injury, which may be serious depending on the circumstance.Warning:1. Installation work and electrical wiring should be done only by qualified personnel inaccordance with all applicable codes, standards and national wiring regulations.2. Use this unit only in the manner intended by the manufacturer. If you have questions,please contact the manufacturer.3. Install the air conditioner in accordance with the instructions in this installation manual.Improper installation may result in water leakage, electric shock or fire.4. Make sure that all wiring is secured, that specified wires are used, and there is no strainon the terminal connections or wires.5. If refrigerant gas leaks during installation, ventilate the area immediately. Do not directlytouch refrigerant that has leaked from refrigerant pipes or other areas, as there is a danger of frostbite.6. Before serving or cleaning unit, switch power off and disconnect power supply.7. When cutting or drilling into wall or ceiling, do not damage electrical wiring or hiddenutilities.8. Be sure to use only the specified accessories and parts to complete installation.9. Protective grounding connection: The enclosure must be grounded at the protectiveground terminal. Use 1.5 mm2 (18AWG) wire and use spring washer to avoid loosening.10. The air conditioner should not be accessible to the general public.11. The installation must contain a device to disconnect all poles of the air conditioner fromthe power supply. The contact distance in all poles must be 3 mm minimum.12. To reduce the risk of electrical shock: Means for disconnection must be incorporated inthe fixed wiring in accordance with the wiring rules.13. This appliance is intended for use only by qualified personnel.14. That the appliance shall be installed in accordance with national wiring regulations.Caution:1. Install the air conditioner on a wall or door strong enough to withstand the weight of theunit.2. Do not block the air inlets or exits.3. Do not install the air conditioner at any place where there is a danger or flammable gasleakage.4. Arrange the drain to ensure complete drainage.5. To avoid injury, do not touch the air inlet or aluminum fins of the unit.6. Watch your step at the time of fin cleaning or air conditioner inspection.7. Do not topple the air conditioner while moving or in storage.8. The hole in the bottom of the air conditioner should be connected to a sealed containerthrough a drain pipe.9. This appliance is not to be used by any persons with reduced physical, sensory or mentalcapabilities, or lack of experience and knowledge, unless they have been given proper supervision or instruction.10. Children should be prevented from playing with the appliance.Specification for ApprovalCustomer :Description : Air conditioner for Equipment with 600 W Rated Cooling Capacity Customer P/N : Rev. :Delta model no. : HEC0600AFS Rev. : 02Sample revision. : Date Code :Sample issue date : Quantity :1 pcINTERNAL EXTERNAL1. Product Instruction1-1. General DescriptionHEC0600AFS is a AC air conditioner with 115VAC power input, it is designed for UL TYPE12 sealed outdoor telecom cabinet to provide stable and optimum internal conditions forequipment and avoid hotspot inside the cabinet.HEC X1A F S(1)(2)(3)(4) (5)1-2. Main Feature & Model Number*Followed thermal balancing test of DIN3168Cooling Capacity with Varied TemperaturePower Consumption with Varied Temperature1-3. Dimensionmm(inch)(1) Material: Case SGCC Sheet.(2) Finish: Powder coating 75 uM Min., Color RAL 7035.(3) Dimensional Tolerance: ±1 mm1-4. Mounting plane Cutoutmm (inch)1-5. Configuration & MaintenanceMake sure the air conditioner surface sealed with mounting flange to avoid water penetrates into shelter through mounting interface. It is suggested to use gaskets sticking on the mounting flange and seal the gap between flange and cabinet with silicone gel during installation. There should be NO any gap surround gaskets to avoid water penetrates into enclosure.The air conditioner is composed as the following key components: they are chassis, cover, controller, heat exchanger, blowers and compressor etc. It is “not” recommended that the user replace the compressor, evaporator, and the condenser by themselves; it may damage the system and getting injured.In order to assure the air conditioner running at optimal condition, the condenser should be cleaned once annually at least; user can clean the condenser with water directly. The external side fan blade can also be cleaned with normal pressure water if there is dust accumulation. Please do not use strong water jet to impact the center of fan and the surface of condenser.The bottom hole of the air conditioner should be connected to a sealed container througha drainpipe, please clear drain holes when the maintenance. Please also notice that:1. Check wires are connected correctly, and the insulation is not cracking or broken.2. Use Self-test to check the unit running correctly or not. And the supplied air of internalside should be as cooled air.3. Do not wipe the product with organic solvent, volatile substances like toluene or gasoline,it will destroy the powder-coated surface.4. Turn off the power before maintaining.5. Please turn off power and remove dry contact connector while non-operating for a longtime.6. If any abnormal acoustic noise from air conditioner happened, please turn off the productand contact with customer services.7. The refrigerant is environmental friendly product of R134a. Little refrigerant leakage (< 5g/ year) is allowed for application. If refrigerant leakage seriously, please turn off the power and wait for at least 2 hours to make sure the refrigerant fully exhaust. Please also contact the services to replace spare parts.8. The compressor electrical protecting cover is sealed with silicon for UL TYPE 4Xrequirement. Please do not dismantle the sealed cover or will lose the quality assurance of the compressor.1-6. Thermal and AirflowInternal and external air flow circulation is shown in below diagram. Counter flow design prevents mixing of internal and external air flows, but waste heat can still be dissipated from cabinet to the ambient outside air. An internal temperature sensor has been placed in the return air stream to provide reliable temperature measurement, and for safe operation.The heated air inside the cabinet will be cooled by the evaporator. Waste heat absorbed by the refrigerant will be dissipated through the condenser at the external side.2. Electrical SpecificationPower Supply & Alarm Connector & Indicator(1) AC Power Connect :(2) RS485 and J1 Connect :J1 Pin Name DescriptionRS485 + RS485 CommunicationRS485 - RS485 Communication NC Dry Output NC COM Dry Output COM NO Dry Output NO 1 Door open alarm input 2Door open alarm inputSystem Alarm Default Setup• Specification: Contact rating: 2A@30 VDC / 2A@250 VAC• Normal: NC and COM dry contact output close•Alarms happening: NC and COM dry contact output open(Dry Contact will trigger when alarm happen except E2.6 and E5.1)Pin DescriptionCable wire size1 PE 18 AWG2 N 18 AWG 3L18 AWGPIN1 PIN2 PIN3(3) Panel operation:•A: Display:A BCIt will show the temperature inside the cabinet and system parametric setup.•B: LED indicator:When the system power on and the LED will light in green.If any alarm happens, according to flashing times of red led to check the root cause.If the system gets into self-test mode and the LED will flash in green.•C: Press Buttons:↑: UP or increase↓: DOWN or decreaseSET: Parametric setup(4) Panel Operation Flowchart :※If no button is pressed, after 20 seconds, the panel will return to the CabinetTemperature screen.※The default value of Password is 0001.SD card & Ethernet (Optional function):The controller used communication technology to remotely control, monitor, SD card 8 GB for logging data and alarm the cooling function of the ACU. This can be done usinga RJ45 or RS485 connected to an industrial network or a personal computer (PC)connected to an Internal local area network.3. Environmental ConditionOperating Temperature-10°C ~ +55 °C (14 °F ~ +131 °F)Storage Temperature-40 °C ~ +70 °C (-40 °F ~ 158 °F)Operation HumidityExternal air loop: 0 ~ 100 % RHInternal air loop: 0 ~ 80 % RH, non-condensingIngress Protection RatingUL TYPE 124. Reliability TableTest item Condition High temperature IEC 60068-2-2Low temperature IEC 60068-2-1High temp. / High humidity IEC 60068-2-3 Temperature cycle IEC 60068-2-14 test Nb Vibration ETSI 300 019-1-4 CLASS 4.1 Ingress protection (external side)IP55 , UL TYPE 4XSalt fog test (external side)IEC 60068-2-52, 6cycles Package bump IEC 60068-2-295. Safety Certification6. AccessoryPower and Alarm Cable:Pin Description Cable wire size1PE18 AWG2N18 AWG3L18 AWG7. Parameters7-1 Parametric Setup※d1.10 and d1.11 are option functions. Default is closed.※d2 layer is for system status information read only.7.2 Self-Test1. Press the SET button into parametric setup mode.2. Press UP button to choose d1.06 and then press SET button to choose “1”executingauto self-test.3. If the system gets into self-test mode and LED will flash in green.4. Auto self-test running period about eighty seconds exclude compressors three minutesprotection.5. The test process including EEPROM, NTC sensor, inner-fan, outer-fan, compressorheater, emergency fan running correctly.6. Recognizing that the implementation process without generating alarm or fault. If anyalarm happens, according to alarm code to check the root cause.7.3 Alarm Logs & Fault ProcessingFault Analysis and Processing8. Installation NoticeCheck the surrounding obstacles to make sure the product get enough space for air circulate.9. ReclaimAt the end of the unit working life, the produce must not be disposed of as urban waste.It must be taken to a special local authority differentiated waste collection center or to a dealer providing this service.10. Versions。
乐维阴电源开关产品说明书
®/powerswitch2Component Switches30 A, 40 A, 60 AManual Motor ControllersOVERVIEWPowerswitch ® industrial grade AC Manual Motor Controllers provide safe, reliable control of a variety of motor loads. Suitable for use as motor disconnect*, these switches are available for both single-phase and three-phase applications, with a continuous current rating at voltages up to 600 VAC and maximum horsepower ratings of 30 hp. Metallic andnon-metallic enclosures are available, including NEMA Type 1, Type 3R, and Type 4X, to suit a wide variety of applications.* 30 A & 40 A onlyMS603-FWMS303-DSWMS403-DSMS303-DSSpowerswitch®ORDERING GUIDE/powerswitch 3FEATURES•All molded parts are thermoplastic to resist impact,chemicals, temperature, tracking and arcing• Cam-driven mechanism enhances fast-make/slow-break • Listed to UL 60947-4-1 (formerly UL 508)• Silver-alloy contacts for maximum conductivity and service life •30 A and 40 A switches feature external clamps for back and side wiring; 60 A switches available in front-wire orback-wire versions•Insulating barrier between terminals provide isolationbetween phases•Nickel-plated brass mounting strap, terminal screw andexternal clamps for superior strength and corrosion resistance •Oversized toggle provides positive actuation,even with gloved hand•Short toggle verisons (DSS) available in 30 A and 40 Afor when shorter depth is required • Backed by a Limited Ten-Year Warranty•30 A standard toggle versions (DSW) available in white‡ MS4X Series Disconnectsare NSF CertifiedEnclosed Switches30 A, 40 A, 60 AN1303-TDSMS4X-303N3303-DSN1303-DSORDERING GUIDE/powerswitch4Stainless Steel Disconnect SwitchesSlope Top 30/32 A, 60 A, Non-FusedFlat Top 30/32 A, 60 A, 80 A, 100 A, Non-FusedMDS6-AXMDS3-AXMDS8-AXMDS3-ASTSafety Disconnect SwitchesOVERVIEWPowerswitch ® safety disconnect switches are designed for superior performance in food and beverage processing,manufacturing, marinas and shipyards, and OEM applications. Available in both stainless steel as well as PBT enclosures these devices are built to withstand the rigors of harsh environments, addressing the needs for safety, washdown procedures, reduced downtime and code compliance. All Powerswitch safety disconnect switches are backed by an industry leading 3 year warranty.powerswitch®IP69KFEATURES• Type 304 stainless steel resists heat, corrosion and abuse •Watertight, dust-tight, submersible and suitable for high pressure, high temperature washdown • IP66, IP67, IP68 and IP69K• UL 50E Type 3R, 4X, 12, 13•Slope top versions feature a 15° slope towards wall,pushing water and debris away from door, handle, gasketand front of device (30/32 A and 60 A versions only)•Overmold handle provides firm grip, durability andwithstands washdown• Handle accommodates 3 padlocks for OSHA compliant lockout/tagout•Removable cover door makes installation and servicingsimple and quick• NSF Certified for hygiene requirements in food & beverage processing•¾" standoff from mounting surface allows for easy cleaning/powerswitch 5ORDERING GUIDESAFETY DISCONNECT SWITCH ACCESSORIES APPEAR ON BACK COVERSlope top versions feature a 15° slope towardswall, pushing water and debris away from door, handle, gasket and front of device(30/32 A and 60 A versions only)/powerswitch6Non-Metallic Disconnect Switches30/32 A, 60 A, 100 A, Fused & Non-FusedFEATURES• PBT enclosure resists impact, abuse and corrosion •Watertight, dust-tight, submersible and suitable for high pressure, high temperature washdown• IP66, IP67, IP68, IP69 and IP69K•UL 50E Type 3R, 4, 4X, 6P , 12, 13•Curve top versions push water and debris away from door, handle, gasket and front of device (30/32 A only)•Overmold handle provides firm grip,durability and withstands washdown• Handle accommodates 3 padlocks for OSHA compliant lockout/tagout• NSF Certified for hygiene requirements in food & beverage processing•Operating temperature ranges from -40°C to 75°C(-40°C to 65°C for Inform units)•Captive, triple head cover screws constructed of stainless steelUnderstand what’s going on inside your devices without maintenance, and minimizing unplanned downtime.LDS60-AXLDS30-F AXLABELLESS DESIGN!Safety Disconnect Switchespowerswitch®All Powerswitch safety disconnect switches from Leviton are certified to NSF International hygiene requirements for food & beverage processing to help ensure public health and safety. Manufacturers, regulators and consumers look to NSF International for thedevelopment of public health standards and certification programs that help protect the world’s food, water, consumer products and environment.LDS30-AXCLDS30-CTSIP69KORDERING GUIDESAFETY DISCONNECT SWITCH ACCESSORIES APPEAR ON BACK COVERCurve top versionspush water and debris away fromdoor, handle, gasket and front of device(Available in 30/32 A only) /powerswitchSafety Disconnect Switch AccessoriesNOTE: Separate mounting bracket needed for attaching fused auxiliary contacts to switch. Contact Customer Service for availability.LEV SeriesMechanical Interlocks with Inform TechnologyLearn more at /levseries•••••ALSO AVAILABLE WITH INFORM!。
奥德维特说明书
PDA 系列产品的设计、制造、检查、试验及特性都应遵照适合的最新版IEC 和中国GB 标准及国际单位SI 制。
GB/T13730《地区电网数据采集与监控系统通用技术条件》GB/50171-92《电气装置安装工作盘、柜及二次回路接线施工及验收规范》DL/T630《交流采样远动终端通用技术条件》DL/478-92《静态继电保护及安全自动装置通用技术条件》GB/50062-92《电力装置的继电保护和自动装置设计规范》GB/T50063-2008《电力装置的电测量仪表装置设计规范》DL/T587-1996《微机继电保护装置运行管理规程》GB/T13729-2002《远动终端通用技术条件》GB/14285-93《继电保护和安全自动装置技术规程》GB/T17626.12-1998《振荡波抗扰度试验》GB/T17626.11-2008《电压暂降、短时中断和电压变化抗扰度试验》GB/T17626.10-1998《阻尼振荡磁场抗扰度试验》GB/T17626.8-2006《工频磁场的抗扰度试验》GB/T17626.6-2008《射频场感应的传导骚扰抗扰度》GB/T17626.5-2008《浪涌(冲击)抗扰度试验》GB/T17626.4-2008《电快速瞬变脉冲群抗扰度试验》GB/T17626.2-2006《静电放电抗扰度试验》GB/T 14047-1993《量度继电器和保护装置》GB 3836.3-2000《爆炸性气体环境用电气设备 第 3 部 分:增安型"e"》JB/T 10613-2006《数字式电动机综合保护装置》GB/T13850-1998《交流电量转换为模拟量或数字信号的电测量变送器》JJG596-1999《电子式电能表检定规程》GB/T17215.321-2008《静止式有功电能表(1级和2级)》GB/T 22264-2008《安装式数字显示电测量仪表》产品标准Contents 目 录A -01综合电力监控仪PDA-120系列B -13 三相智能型电力仪表 PDA-103系列C -31单相智能型电力仪表 PDA-101系列D -51 智能型电动机保护控制器 PDA-110MRK F -66参考设计图附录产品业绩G -73GB/T17215.322-2008《》静止式有功电能表(0.2S 级和0.5S 级)E -58 低压电动机保护装置 ADVP-1451产品简介功能详表产品特点PDA -120系列综合电力监控仪是北京奥德威特电力科技股份有限公司按IEC 国际标准开发,与当今国际先进技术同步的网络化综合电力监控仪表。
电子产品EPM Serie 2-3W宽输入范围DC-DC转换器说明说明书
Selection Guide 2:1 2W OutputMODEL NUMBER INPUTVOLTAGE(VDC)OUTPUTVOLTAGE(VDC)OUTPUTCURRENT(mA)INPUT6CURRENT(mA) EFF(%)7ISOLATION8(VDC)PACKAGEFULLLOADNOLOADPM22-01(-3K) 4.5-9 3.3 500 465 50 71 1500(3000) H PM22-02(-3K) 4.5-9 5 400 555 50 72 1500(3000) H PM22-03(-3K) 4.5-9 9 222 519 50 77 1500(3000) H PM22-04(-3K) 4.5-9 12 150 480 50 75 1500(3000) H PM22-05(-3K) 4.5-9 15 120 456 50 79 1500(3000) H PM22-06(-3K) 9-18 3.3 500 205 30 67 1500(3000) H PM22-07(-3K) 9-18 5 400 219 20 76 1500(3000) H PM22-08(-3K) 9-18 9 222 225 20 74 1500(3000) H PM22-09(-3K) 9-18 12 168 209 20 80 1500(3000) H PM22-10(-3K) 9-18 15 133 209 20 80 1500(3000) H PM22-11(-3K) 9-18 24 83 213 20 78 1500(3000) H PM22-12 9-18 +/-5 +/-200 225 20 74 1500 H PM22-13 9-18 +/-12 +/-83 225 20 74 1500 H PM22-14 9-18 +/-15 +/-67 225 20 74 1500 H PM22-15(-3K) 18-36 3.3 500 93 12 74 1500(3000) H PM22-16(-3K) 18-36 5 400 110 12 76 1500(3000) H PM22-17(-3K) 18-36 9 222 111 13 75 1500(3000) H PM22-18(-3K) 18-36 12 168 104 11 80 1500(3000) H PM22-19(-3K) 18-36 15 133 105 11 79 1500(3000) H PM22-20(-3K) 18-36 24 83 107 11 78 1500(3000) H PM22-21 18-36 +/-5 +/-200 112 12 74 1500 H PM22-22 18-36 +/-12 +/-83 112 12 74 1500 H PM22-23 18-36 +/-15 +/-67 112 12 74 1500 H PM22-24(-3K) 36-75 3.3 500 46 8 75 1500(3000) H PM22-25(-3K) 36-75 5 400 56 8 74 1500(3000) H PM22-26(-3K) 36-75 9 222 55 8 75 1500(3000) H PM22-27(-3K) 36-75 12 168 51 8 82 1500(3000) H PM22-28(-3K) 36-75 15 133 51 8 82 1500(3000) H PM22-29(-3K) 36-75 24 83 54 8 77 1500(3000) H PM22-30 36-75 +/-5 +/-200 56 8 74 1500 H PM22-31 36-75 +/-12 +/-83 54 8 77 1500 H PM22-32 36-75 +/-15 +/-67 54 8 77 1500 H Note: Other input to output voltages may be available. Please contact factory.FOR EXAMPLE: PM22-12(H PACKAGE 2W SINGLE OUTPUT 1500VDC ISOLATION)PM22-11(-3K)(H PACKAGE 2W SINGLE OUTPUT 3000VDC ISOLATION)6NOMINAL INPUT VOLTAGE.7 NOMINAL INPUT VOLTAGE, FULL LOAD.Selection Guide 2:1 2W OutputMODEL NUMBERINPUTVOLTAGE(VDC)OUTPUTVOLTAGE(VDC)OUTPUTCURRENT(mA)INPUT9CURRENT(mA) EFF(%)10ISOLATIO N11(VDC)PACKAGEFULLLOADNOLOADPM22-33 4.5-9 3.3 500 465 50 71 1500 J PM22-34 4.5-9 5 400 555 50 72 1500 J PM22-35 4.5-9 9 222 519 50 77 1500 J PM22-36 4.5-9 12 150 500 50 72 1500 J PM22-37 4.5-9 15 120 500 50 72 1500 J PM22-389-18 3.3 500 205 30 67 1500 J PM22-399-18 5 400 219 20 76 1500 J PM22-409-18 9 222 225 20 74 1500 J PM22-419-18 12 168 213 20 78 1500 J PM22-429-18 15 133 213 20 78 1500 J PM22-439-18 24 83 213 20 78 1500 J PM22-4418-36 3.3 500 93 12 74 1500 J PM22-4518-36 5 400 112 12 74 1500 J PM22-4618-36 9 222 111 13 75 1500 J PM22-4718-36 12 168 107 11 78 1500 J PM22-4818-36 15 133 107 11 78 1500 J PM22-4918-36 24 83 107 11 78 1500 J PM22-5036-75 3.3 500 52 8 67 1500 J PM22-5136-75 5 400 56 8 74 1500 J PM22-5236-75 9 222 55 8 75 1500 J PM22-5336-75 12 168 51 8 82 1500 J PM22-5436-75 15 133 51 8 82 1500 J PM22-5536-75 24 83 54 8 77 1500 J Note: Other input to output voltages may be available. Please contact factory.9NOMINAL INPUT VOLTAGE.10 NOMINAL INPUT VOLTAGE, FULL LOAD.Selection Guide 4:1 2W OutputMODEL NUMBERINPUTVOLTAGE(VDC)OUTPUTVOLTAGE(VDC)OUTPUTCURRENT(mA)INPUT12CURRENT(mA) EFF(%)13ISOLATION14(VDC)PACKAGEFULLLOADNOLOADPM24-01(-3K) 9-36 3.3 500 205 30 70 1500(3000) H PM24-02(-3K) 9-36 5 400 222 20 74 1500(3000) H PM24-03(-3K) 9-36 9 222 225 20 74 1500(3000) H PM24-04(-3K) 9-36 12 165 213 20 78 1500(3000) H PM24-05(-3K) 9-36 15 133 213 20 78 1500(3000) H PM24-06(-3K) 9-36 24 83 213 20 78 1500(3000) H PM24-07 9-36 +/-15 +/-67 220 20 76 1500 H PM24-08(-3K) 18-75 3.3 500 98 12 70 1500(3000) H PM24-09(-3K) 18-75 5 400 112 12 74 1500(3000) H PM24-10(-3K) 18-75 9 222 112 13 74 1500(3000) H PM24-11(-3K) 18-75 12 165 107 11 78 1500(3000) H PM24-12(-3K) 18-75 15 133 107 11 78 1500(3000) H PM24-13(-3K) 18-75 24 83 107 11 78 1500(3000) H Note: Other input to output voltages may be available. Please contact factory.12NOMINAL INPUT VOLTAGE.13 NOMINAL INPUT VOLTAGE, FULL LOAD.Selection Guide (4) 2:1 3W OutputMODEL NUMBERINPUTVOLTAGE(VDC)OUTPUTVOLTAGE(VDC)OUTPUTCURRENT(mA)INPUT15CURRENT(mA) EFF(%)16ISOLATION17(VDC)PACKAGEFULLLOADNOLOADPM32-01(-3K) 4.5-9 3.3 700 641 100 72 1500(3000) H PM32-02(-3K) 4.5-9 5 600 800 100 75 1500(3000) H PM32-03(-3K) 4.5-9 9 333 778 100 77 1500(3000) H PM32-04(-3K) 4.5-9 12 250 779 100 77 1500(3000) H PM32-05(-3K) 4.5-9 15 200 779 100 77 1500(3000) H PM32-06 4.5-9 +/-5 +/-300 789 100 76 1500 H PM32-07 4.5-9 +/-12 +/-125 779 100 77 1500 H PM32-08 4.5-9 +/-15 +/-100 779 100 75 1500 H PM32-09(-3K) 9-18 3.3 700 263 45 73 1500(3000) H PM32-10(-3K) 9-18 5 600 336 45 74 1500(3000) H PM32-11(-3K) 9-18 9 333 320 45 78 1500(3000) H PM32-12(-3K) 9-18 12 250 320 45 78 1500(3000) H PM32-13(-3K) 9-18 15 200 310 45 81 1500(3000) H PM32-14 9-18 +/-5 +/-300 324 45 77 1500 H PM32-15 9-18 +/-12 +/-125 320 45 78 1500 H PM32-16 9-18 +/-15 +/-100 320 45 78 1500 H PM32-17(-3K) 18-36 3.3 700 128 20 75 1500(3000) H PM32-18(-3K) 18-36 5 600 162 20 77 1500(3000) H PM32-19(-3K) 18-36 9 333 152 20 82 1500(3000) H PM32-20(-3K) 18-36 12 250 158 20 79 1500(3000) H PM32-21(-3K) 18-36 15 200 154 20 81 1500(3000) H PM32-22 18-36 +/-5 +/-300 162 20 77 1500 H PM32-23 18-36 +/-12 +/-125 158 20 79 1500 H PM32-24 18-36 +/-15 +/-100 158 20 79 1500 H PM32-25(-3K) 36-75 3.3 700 66 12 73 1500(3000) H PM32-26(-3K) 36-75 5 600 81 12 77 1500(3000) H PM32-27(-3K) 36-75 9 333 80 12 78 1500(3000) H PM32-28(-3K) 36-75 12 250 79 12 79 1500(3000) H PM32-29(-3K) 36-75 15 200 76 12 82 1500(3000) H PM32-30(-3K) 36-75 24 125 79 12 79 1500(3000) H PM32-31 36-75 +/-5 +/-300 81 12 77 1500 H PM32-32 36-75 +/-12 +/-125 79 12 79 1500 H PM32-33 36-75 +/-15 +/-100 79 12 79 1500 H15NOMINAL INPUT VOLTAGE.16 NOMINAL INPUT VOLTAGE, FULL LOAD.Input Fuse Selection Guide4.5-9VINPUT VOLTAGE(VDC) 9-18V(9-36V) INPUT VOLTAGE(VDC) 18-36V(18-75V) INPUT VOLTAGE(VDC)36-75V INPUT VOLTAGE(VDC) 2000mA Slow-Blow Type1000mA Slow-Blow Type500mA Slow-Blow Type 200mA Slow-Blow TypeNote: Certain applications may require the installation of external fuse in front of the input.EPM 2-3 Watt Series Application Notes: EXTERNAL CAPACITANCE REQUIREMENTS:No external capacitance is required for operation of the EP 2-3 Watt series.To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm from DC to 100KHz is required.External output capacitance is not required for operation, however it is recommended that 10uF tantalum and 0.1uF ceramic DC-DCCONVERTER+Vin-Vin+Vout-VoutOUTPUTINPUT。
乐维顿制造公司LED灯光控制器说明书
Leviton Manufacturing Co., Inc. Lighting & Controls10385 Avery Street, Tualatin, OR 97062 tel 800-736-6682 tech line (6:00AM-4:00PM PT Mon-Fri) 800-959-6004 ©2022 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.DescriptionThe Integrated Room Control (IRC) Lighting Controller is a Decora ® devices for controlling non-dimmable and dimmable luminaries connected to the IRC Controller. The IRC Lighting Controller provides a unique control station with multi-function capabilities available in a 4-button configuration. The device come in white with a matching wallplate and color change kit available.OperationThe IRC Lighting Controller works in conjunction with the features of the IRC which offers daylight harvesting, occupancy sensing, time clock inputs and manual-ON and partial-ON capabilities.• RL VSW-4LW provides 4-button ON/OFF and Dim/Brightcontrol as well as a Full Bright optionIntegrated Room Control (IRC) Lighting ControllerFeatures• Function description:• ON—all lights to daylight harvesting level• Bright—raise light levels with press hold or multiple press, temporary override of daylight harvesting level• Dim—lower light levels with press hold or multiple press, temporary override of daylight harvesting level• OFF—turn off lights• Designer Decora styling complements any interior for sleek aesthetics• Entry station utilizes industry standard buttons for room lighting control• Can be used with stand-alone IRC System• Enables Ladderless Commissioning™ of IRC Systems. Modify the daylight harvesting target level with the4-button controller.1,2 & 4 Button Controllers A 1.65” (42.06mm)B4.60” (117.07mm)C 2.75” (69.85mm)D 0.37” (9.55mm)E 1.16” (29.51mm)F2.68” (68.25mm)DimensionsG-9310E/E22-aa REV JAN 2022Leviton Manufacturing Co., Inc. Lighting & Controls10385 Avery Street, Tualatin, OR 97062 tel 800-736-6682 tech line (6:00AM-4:00PM PT Mon-Fri) 800-959-6004Leviton Manufacturing Co., Inc. Global Headquarters201 North Service Road, Melville, NY 11747-3138 tel 800-323-8920 tech line (8:30AM-7:00PM ET Mon-Fri) 800-824-3005Visit our Website at: /irc©2022 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.Wiring DiagramONOFF+24VDCPilotCommon*Replace x to indicate color: White (W), Ivory (I), Light Almond (T), Gray (G), Black (E) and Red (R).。
德尔塔电气 DDC-3000 3200 3400 恒温器 产品说明书
SpecificationsAirApprovalsANSI / ASHRAE Standard 130ETL listed to meet requirements of UL 1995 and CSA 236SoundAHRI 880 Certified Box LinersAvailable in fiberglass, foil face, closed cell (EPFI), or metal-linedUL 181 and NFPA 90A compliance Insulation meets ASHRAE 62.1requirements for resistance to mold growth and erosion Welding seamsContinuous welded primary inlet duct to minimize leakage with 3 stiffening beads for added rigidityWaterPressure TestsCoils proof tested at 450 psig and leak tested at 300 psig air pressure under water. Factory pressure tested at 100 psig, shipped with 40-50 psigrecharged, includes gauge to indicate that unit is leak free HydronicsPre-assembled Y-strainer with PT port, drain and isolation valve, ATC valve, manual air vent, union and balancing valve with PT ports H2O CoilCoil Casing- 20 Ga. galvanized steel Coil Tubing- 12.7 mm (0.5 in.) O.D., 0.4 mm copper (0.016 in.) walls Coil Fins- 1.14 mm (0.045 in.) aluminum, 10 fins per inchConstruction22 Ga. galvanized steel casing,mechanically sealed for low leakage with 14 Ga. rigid support handlesNEMA 1 (standard) /UL 508A (optional) certified control enclosureDescriptionThe Zone Control Unit (ZCU) is a complete VAV terminal unit with a Delta Controls controller that is delivered pre-assembled to the job site and ready for immediate installation. Delta controllers are pre-programmed and factory commissioned.ApplicationZCU is a complete pre-engineered VAV bundled solution delivered at a lower installed cost. Ready for immediate installation and designed for standard VAV applications and seismic-sensitive buildings.It serves large zone areas in commercial spaces, such as for e.g. office buildings, to provide fresh air and heating or cooling foroccupants’ comfort and health.FeaturesDesigned to increase the profitability of projects with VAV boxes by lowering the total construction cost and time.Reduces the overall project risk with a single source of responsibility Includes Delta VAV controller, valves, damper, actuators, coil and piping, integrated shipping supports and handlesPre-fabricated wiring harness, UL/ULC 508A listedShipped pressurized with gaugeattached to ensure a leak-free delivery Made-to-order to meet your site’s requirementsZCUDelta Zone Control UnitSpecifications (Continued)ControlsNative BACnet application controllersAmbient0°C to 55°C (32°F to 131°F)10% to 95% RH (non-condensing)PowerDVC-V304- 24 VAC 50/60 Hz @ 15 VA(not including output loading, 52 VAmax with fully loaded TRIAC Outputs)DVC-V304E- 24 VAC @ 15 VA, 60 VA maxwith fully loaded TRIACSDVC-V304-PoE- PoE Power In802.3at PoE: 53 VDC, 25.5 W max802.3af PoE: 48 VDC, 12.95 W maxDVC-V322- 24 VAC 50/60 Hz @ 15 VA (32VA max with fully loaded TRIACOutputs)DVC-V322E- 24 VAC @ 15 VA, 35 VA maxwith fully loaded TRIACSDVC-V322-PoE- PoE Power In802.3at PoE: 53 VDC, 25.5 W max802.3af PoE: 48 VDC, 12.95 W maxeZVP-440 and eZVP-440E- 24 VAC,50/60 Hz, 85 VA max (11 VA excludingTRIAC loading)Typical ZCU Piping ArrangementCopyright © 2020 Delta Controls. All rights reserved.Subject to change without notice.Ordering*******************************************************************.eZNS-T100enteliZONE Network Sensor: LINKnet room stat with multiple display, button, andinput sensor optionsCON-768BT Delta MS/TP to Bluetooth Network ConverterCON-ENOC-868Delta Controls EnOcean Zone Gateway, supporting 32 devices, 868 MHzEuropeCON-ENOC-902Delta Controls EnOcean Zone Gateway, supporting 32 devices, 902 MHzNorth AmericaAccessoriesenteliZONE is a registered trademark of Delta ControlsInc.BACnet is a registered trademark of the American Societyof Heating, Refridgerating and Air-ConditioningEngineers, Inc.Updated February 13, 2020Dimensions in inches (mm)Use the following part number tables to determine the correct part number you should use to order a ZCU.Example ZCU OrderPre-engineered VAV box with hot water reheat coil, 14 in. inlet size, 1 in. poly armor liner, no fan, 1-row coil, no fan motor, duct extension, with both controls and piping location on the right-hand side, with Delta Controls controller eZVP-440-AFS, without transformer and disconnect, ATC assembly which includes ball brass valve, 1/2 in., 3-way, 1.2 Cv and a 24V non-spring returnactuator with modulating control, with sliding controller’s enclosure and 24 in. stainless steel hose kit.ZCU Part NumbersThe part number for this example is ZH-3-14-7-0-1-0-4-RR-DC-4-0-19-2-2.Abbreviations: ATC = Automatic Temperature Control CO = Cooling Only DH = High Performance Dual Duct Terminal Unit DVC = Delta Variable Air Volume controller eZV = enteliZONE VAV controller SCI = Series Fan-Powered Terminal Unit SH = Single Duct Terminal Unit SS = Stainless Steel SVI = Parallel Fan-Powered Terminal Unit WC = Hot water reheat。
欧特保蓄电池参数
欧特保蓄电池参数欧特保蓄电池参数概述:欧特保蓄电池是一种高性能的铅酸蓄电池,具有长寿命、高能量密度、低自放电率、优异的充放电性能等优点,广泛应用于通信、UPS、太阳能等领域。
一、型号及规格欧特保蓄电池型号包括OPzV、OPzS两种,规格从2V到12V不等。
其中OPzV系列主要应用于太阳能系统和UPS系统中,而OPzS系列则主要应用于通信基站和UPS系统中。
二、额定容量欧特保蓄电池的额定容量是指在标准条件下(25℃),在规定时间(通常是10小时)内放出的总电量。
其额定容量范围从100Ah到3000Ah不等。
三、充放电性能1.充电性能:欧特保蓄电池具有良好的充电性能,可以采用恒流恒压充电方式进行快速充电。
其最大允许充电电流为C10倍率,即在10小时内将额定容量全部充满。
2.放电性能:欧特保蓄电池具有稳定的放电性能,在C10倍率下,其放电时间可达10小时。
同时,其最大允许放电电流为C5倍率,即在5小时内将额定容量全部放完。
四、循环寿命欧特保蓄电池的循环寿命是指在规定的充放电条件下,可以循环使用的次数。
根据不同的型号和规格,欧特保蓄电池的循环寿命可以达到2000次以上。
五、自放电率欧特保蓄电池具有极低的自放电率,在25℃下,其自放电率仅为每月1%左右。
这意味着即使长时间不使用,也可以保持较长时间的储存能力。
六、温度范围欧特保蓄电池适用于广泛的温度范围,在-20℃到55℃之间均可正常工作。
但在较低温度下,其容量会有所降低。
七、安全性能欧特保蓄电池具有良好的安全性能,在正常使用过程中不会出现泄漏、爆炸等情况。
同时,在设计和生产过程中采用了多重安全防护措施,确保用户使用时的安全性。
结语:以上就是欧特保蓄电池的主要参数介绍。
作为一种高性能的蓄电池,欧特保蓄电池在通信、UPS、太阳能等领域得到了广泛应用,其优异的性能和可靠性受到了用户的一致好评。
贝视特3000w移动电源说明书
贝视特3000w移动电源说明书
1.这是一个体积轻巧,方便携带的多功能电源系统,方便您外出货旅行时,无论身在任何坏境,可即时为您的携带式电子产品充电(列如:手机,MP3/4/5,ipad,蓝牙,游戏机,媒体,播放器或部分型
号相机,摄像机)本说明书叙述有关如何使用本产品及重要安全事项,请先阅读并保留本说明书,以便日后作参考。
2.重要安全事项
使用移动电源前,请仔细阅读以下简明的规则并自觉遵守。
1.移动电源初次使用或长期储存后再使用时,移动电源主机可能已自动逐渐放电,一般需要在5-6次完全充电和放电的周期后才能达到最佳性能。
2.请使用指定充电器及认可配件,包括充电连接线及输电转接头。
3.使用未经可的电源充充电器及配件,可能会损坏您的携带式电子产品和移动电源的机。
4.应在通风的位置充电,过高或过低的温度将影响电池的性能。
5.不要把本产品放在水里。
或受潮雨灯淋。
6.请勿扔掷强烈摔打震动货摇晃本产品,否则可能会破坏内部精密的零件和完好的结构。
7.请妥善保存本产品及相关配件,避免置于儿童容易触及的地方。
8.充电时,移动电源主机会轻微发热,这是正常现象。
9.勿将移动电源主机接近火源货其他热源,以免产生危险。
10.避免让金属物品接触移动电源主机的充电和放电插口,否则会产生短路,损坏主机。
11.未经授权产品改动或自行修理可能会使您无法正常使用本产品及保修失效。
12.请您根据当地法律,章程及限制,适当使用移动电源主机,当遇到未经许可的情况,如飞机升降或位于医疗仪器附近时,应避免充电,并需立即关闭您的手机或其他电子产品,以免造成干扰。
Eaton PDG23M0225P2WJ 电源防御模具封闭电路保护器说明说明书
Eaton PDG23M0225P2WJEaton Power Defense molded case circuit breaker, Globally Rated, Frame 2, Three Pole, 225A, 65kA/480V, PXR25 LSI w/ Modbus RTU, ZSI and Relays, Standard Line and Load (PDG2X3TA225)General specificationsEaton Power Defense molded case circuit breakerPDG23M0225P2WJ 78667924507188.9 mm 152.4 mm 104.6 mm 1.82 kg Eaton Selling Policy 25-000, one (1) year from the date of installation of theProduct or eighteen (18) months from thedate of shipment of the Product,whichever occurs first.RoHS Compliant UL 489CCC MarkedCSAIEC 60947-2Product NameCatalog Number UPCProduct Length/Depth Product Height Product Width Product Weight WarrantyCompliancesCertificationsZSI / Modbus / Relays65 kAIC at 480 Vac2600225 AThree-pole600 VPD2 Global22 kAIC Icu @125 Vdc100 kAIC @240V (UL)50 kAIC Icu/ 30 kAIC Ics/ 105 kAIC Icm @480V Brazil (IEC) 65 kAIC @480V (UL)30/25 kAIC Icu/ 15/13 kAIC Ics @525V South Africa (IEC) 22 kAIC Icu @250 Vdc35 kAIC @600V (UL/CSA)50 kAIC Icu/ 40 kAIC Ics/ 105 kAIC Icm @440V (IEC)10 kAIC Icu/ 5 kAIC Ics/ 21 kAIC Icm @690V (IEC)70 kAIC Icu/ 53 kAIC Ics/ 154 kAIC Icm @380-415V (IEC) 100 kAIC Icu/ 100 kAIC Ics/ 220 kAIC Icm @240V (IEC)25 kAIC @600V (UL/CSA)ElectronicClass AComplete breakerStandard Line and Load Eaton Power Defense MCCB PDG23M0225P2WJ 3D drawingPower Xpert Protection Manager x32Consulting application guide - molded case circuit breakersPower Xpert Protection Manager x64Power Defense brochurePower Defense molded case circuit breaker selection posterPower Defense technical selling bookletPower Defense molded case circuit breakers - Frame 2 product aidMolded case circuit breakers catalogPower Xpert Release trip units for Power Defense molded case circuit breakersPDG4 CCC certificationPDG4 CB reportPower Defense Declaration concerning California’s Proposition 65PDG2 CB reportEU Declaration of Conformity - Power Defense molded case circuit breakersPower Defense Frame 2 global terminal shield, 3 pole - IL012330EN Power Defense Frame 2 Direct Rotary Handle Assy With Interlock Version Instructions (IL012138EN).pdfPower Defense Frame 2 screw terminal_end cap kit, 225A, 3 pole instructions - IL012258EN H01Power Defense Frame 1 IEC and Frame 2 Rotary Mechanism with NFPA Handle Attachment Instructions (IL012260EN).pdfPower Defense Frame 2 tunnel terminal (aluminum), 50A, 3 pole instructions - IL012236EN H03Power Defense Frame 2 handle mech direct rotary handle instructions - IL012134ENPower Defense Frame 2 motor circuit protector (HMCP) - IL012326EN Power Defense Frame 2 handle mech variable depth rotary handle instructions - IL012136ENPower Defense Frame 2 Bell Alarm Switch Instructions (IL012154EN).pdfSpecial featuresInterrupt ratingFrameRated operation voltage (Ue) at AC - max Amperage RatingNumber of polesVoltage rating - maxCircuit breaker typeInterrupt rating rangeSwitch off techniqueClassCircuit breaker frame typeTerminals 3D CAD drawing package Application notesBrochuresCatalogsCertification reports Installation instructions600 Vac PXR 25 LSI Modbus RTU Power Defense Frame 2 terminal kit - PDG2X3(2)(4)TA150RF instructions - IL012244EN H01Power Defense Frame 2 shunt trip UVR instructions - IL012130EN Power Defense Frame 2 clamp terminal (steel), 20A, 3 pole instructions - IL012246EN H03Power Defense Frame 2 locking devices and handle block instructions - IL012149ENPower Defense Frame 2 tunnel terminal kits - PDG2X1TA225K instructions- IL012239EN H01Power Defense Frame 2 tunnel terminal (aluminum), 150A, 3 pole instructions - IL012238EN H03Power Defense Frame 2 terminal kit - PDG2X3(2)(4)TA225RF instructions - IL012245EN H01Power Defense Frame 2 multi wire connector kit -PDG2X3(2)(4)TA2253W instructions - IL012243EN H01Power Defense Frame 2/3/4/5/6 voltage neutral sensor module wiring instructions – IL012316ENPower Defense Frame 2 multi wire connector kit -PDG2X3(2)(4)TA2256W instructions - IL012242EN H01Power Defense Frame 2 PDG2 and PDC(E)9 breaker instructions -IL012106ENPower Defense Frame 1-2-3-4 IP door barrier assembly instructions -IL012278ENPower Defense Frame 2 tunnel terminal (aluminum), 100A, 3 pole instructions - IL012237EN H03Power Defense Frame 2 box terminal (steel), 100A, 3 pole instructions - IL012234EN H03Power Defense Frame 2 box terminal (aluminum), 225A, 3 pole instructions - IL012235EN H03Power Defense Frame 2 TMTU Aux, Alarm, ST and UVR Animated Instructions.rhPower Defense Frame 2 Locking Devices and Handle Block Animated Instructions.pdf.rhPower Defense Frame 2 Handle Mech Variable Depth Rotary Handle Animated Instructions.rhPower Defense Frame 2 withTMTU, Shunt Trip_UVR Animated Instructions.rhPower Defense Frame 2 Bell Alarm with PXR Animated Instructions.pdf.rhPower Defense Frame 2 Aux, Alarm, Shunt Trip, and UVR How-To Video Power Defense Frame 2 Direct Rotary Handle Mechanism Installation How-To VideoVoltage ratingTrip TypeCommunicationInstallation videosMultimediaEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaPower Defense Frame 3 Variable Depth Rotary Handle Mechanism Installation How-To VideoPower Defense Frame 2 Variable Depth Rotary Handle Mechanism Installation How-To VideoPower Defense molded case circuit breakers Power Defense Frame 6 Trip Unit How-To Video Eaton Power Defense for superior arc flash safety Power Defense Frame 5 Trip Unit How-To Video Power Defense Breakers Eaton Specification Sheet - PDG23M0225P2WJ Power Defense time current curve Frame 2 - PD2Power Defense time current curves MCP Motor Circuit Protection – PD1, PD2, PD3Single and double break MCCB performance revisited Making a better machineIntelligent circuit protection yields space savings Intelligent power starts with accurate, actionable data Molded case and low-voltage power circuit breaker health Molded case and low-voltage breaker health Safer by design: arc energy reduction techniquesSpecifications and datasheetsTime/current curvesWhite papers。
康特尔智能调节仪说明书
康特尔智能调节仪说明书
警告
1.在以下情况下使用这个设备,如(核能控制、医疗设备、汽车、火车,飞机、航空、娱乐或安全装置等),需要安装安全保护装置,或联系我们索取这方面的资料,否则会引起严重的损失,火灾或人身伤害。
2.必须要安装面板,否则可能会发生触电。
3.在供电状态中不要接触接线端子,否则可能会发生触电。
4.不要随意拆卸和改动这个产品,如确实需要请联系我们,否则会引起触电和火灾。
5.请在连接电源线或信号输入时检查端子号,否则会引起火灾。
注意
1.这个装置不能使用在户外。
否则会缩短此产品的使用寿命或发生触电事故。
2当电源输入端或信号输入端接线时,No.20AWG(0.50mm')螺丝拧到端子上的力矩为0.74n·m-0.9n·m否则可能会发生损坏或连接端子起火。
3.请遵守额定的规格。
否则会缩短这个产品的寿命后发生火灾。
4.清洁这个产品时,不要使用水或油性清洁剂。
否则会发生触电或火灾,也将损坏本产品。
5.在易燃易爆,潮湿,太阳光直射,热辐射,振动等场所应避免使用这个单元。
否则可能会引起仪表不能正常工作。
6.在这个单元中不能有流尘或沉淀物。
否则可能会引起火灾或机
械故障。
7.不要用汽油,化学溶剂清洁仪表外壳。
使用这些溶剂会损害仪表外壳。
请用柔软的湿布(水或酒精〉清洁塑料外壳。
霍尼韦尔DPT系列微差压变送器技术说明书
1产品概述技术说明书 HBT -G.C.-Building -FDSS -SEP -2019-CN01 DPT 系列 压差传感器DPT 系列微差压变送器用于测量差压或表压, 提供低至+/-50Pa, 高至0-10kPa 的量程,适用于: ∙ HVAC 暖通空调∙ 智能楼宇能源管理∙ 环境保护∙ VAV 及风阀控制∙ 过滤系统及风扇监控∙ 洁净间压力及管道风速监控产品特点∙ 全不锈钢电容型敏感元件∙ 良好的温度稳定性和长期稳定性∙ 电源误接线保护∙ 翻盖设计方便现场接线和维护技术参数 性能参数 精度(RSS)(恒温下) ±1.0%FS 工作温度 0...50 °C 工作湿度 0...95%RH(不凝露) 储存温度 -10...+70 °C 温度影响(零点/满程偏移) ±0.06%FS/°C 长期稳定性 ±1.0%FS/Year 安装位置影响 ±0.6%FS(最大值) 响应时间 <20ms (63%FS) 测量介质 空气或无腐蚀性不导电气体 压力接口 3/16”(4.8mm)外径接口 电气接口 可插拔式接线端子 外壳材质 聚碳酸酯(UL94V -0 认证) 外壳防护等级 IP65 重量 约 220 克 认证 CE 电气参数 供电电压(电压型) 12...30 Vac/Vdc 供电电压(电流型) 9...30 Vdc 输出阻抗(电压型) 100 欧姆 负载范围(电流型) 0...800 欧姆 安装和使用注意事项 ∙ 推荐垂直安装于无震动表面,避免底面向上倒装 ∙ 安装后可以微调零点电位器以消除误差 ∙ 信号线布线应远离高压及动力线路以避免干扰 ∙ 禁用高压气体清洁气管和压力接口以免过压损坏 ∙ 没有高精度压力基准源时请勿进行满量程调整2霍尼韦尔环境自控产品(天津)有限公司 天津经济技术开发区南海路158号邮编:300457电话:+86-22-66287000传真:+86-22-25325214说明书如有变动,不另行通知。
2-桿、3线电源保护设备说明书
Description2-pole, 3-wire grounding 15A, 125V/AC 20A, 125V/ACDesign features•Provides both arc fault protection per UL1699A and ground fault protection per UL943 in one convenient device•Protects from both series and parallel arcs downstream from the Outlet Branch Circuit (OBC) AF/GF receptacle• OBC AF/GF receptacles also protect from upstream series arcs • Trip indicators make it easy to diagnose arc and ground faults •Device self-tests periodically to ensure proper function of both the ground fault and arc fault protection elements•Meets and exceeds 10ka short circuit testing and Underwriters Laboratories (UL) UL943 safety standards•Ground termination with backwire clamp provides secure wiring and reduces installation time•Automatic grounding system eliminates the need for bonding jumper in grounded metal enclosure; provides redundant measure of ground continuity when jumper is used•Tapered backwire openings handle multiple wire sizes and types for applications up to #10 AWG solid or stranded wire•When downstream receptacles are wired from load side, a 20A feed-through rating offers full protection•Lock-out functionality prevents miswired line-load connections and GFCI/AFCI circuitry damage•Visual indicator light provides quick visual reference of a tripped or “end of life” condition•Tamper resistant (TR) shutters comply with 2014 NEC Article 406.12• Terminal screws backed out and ready to wire•Matching standard size thermoplastic wallplate includedTRAFGF15WTRAFGF20LAProject Name:Prepared By:Project Number:Date:Catalog Number:Type:OBC AF/GF duplex receptacleCompliances, specifications and availability are subject to change without notice.T able 1. S pecification grade AF/GF duplex receptaclesRatingCatalog no.DescriptionA V/AC NEMAColor suffixTRAFGF15___Duplex self test AF/GF with standard-size wallplate, back & side wire151255-15RA, B, BK, GY, LA, V, W TRAFGF20___Duplex self test AF/GF with standard-size wallplate, back & side wire201255-20RA, B, BK, GY, LA, V, WTechnical DataEffective May 2016AFGFDuplex Receptacle2EATON Compliances, specifications and availability are subject to change without notice.Catalog no.TRAFGF15, TRAFGF20Top housing Thermoplastic, polypropylene Bottom housing Thermoplastic, PVCStrap0.047” thick steel, zinc-plated Line contacts 0.030” thick brass Ground contactBrassTerminal & ground screws #8-32 steel, brass-plated; neutral screw nickel-plated, ground screw green Terminal clamps0.070” thick steelT able 2. SpecificationsT able 3. MaterialsFor ordering devices, include Cat. no. followed by the color code: A (Almond), B (Brown), BK (Black), GY (Gray), LA (Light Almond), V (Ivory), W (White)Project Name:Prepared By:Project Number:Date:Catalog Number:Type:Catalog no.TRAFGF15, TRAFGF20Device type OBC AFCI/GFCI duplex receptacle Wiring typeBack & side wireTesting & code compliance• cULus Listed to UL 498 and UL 943, file no. E482200•M eets all UL 943 (GFCI), UL 498 (receptacles), UL1699A and applicable CSA requirements • NOM certifiedEnvironmental specifications Flammability: Meets UL 94 requirements; V2 rated Temperature rating: -35ºC to 66ºC (-31ºF to 150.8ºF)Electrical specificationsDielectric voltage: Withstands 2000V per UL 498Current interrupting: Yes, at full-rated current Temperature rise: M ax. 30ºC (86°F) after 100 cycles of overload @ 150% ofrated current (DC)Trip time: 0.025 seconds (Class A)Frequency: 60 Hz; Voltage: 125V; Amperage: 15A/20A 20A feed-through Short circuit testing: Meets and exceeds 10 kA Maximum interrupting capacity: 20 Amps Mechanical specificationsTerminal accommodation: #14 - 10 AWG Voltage ratings: Permanently marked on deviceT able 4. Color ordering informationAF/GF receptacles are designed with the safety of the user in mind. Eaton’s AF/GF receptacles protect against both unexpected paths to ground and unseen arc faults that can result in electrical fires. The NEC requires GFCI or AFCI protection on certain circuits in residential, commercial, and industrial – in some cases both AFCI and GFCI protection are required on the same circuit. These receptacles are UL Listed and fully compliant with all of the latest UL943 Class A GFCI and UL1699A requirements. Eaton’s AF/GF receptacles include tamper resistant shutters to provide compliance with the 2014 NEC Article 406.12 that states that all receptacles installed in dwelling units must be tamper resistant. Additionally, these AF/GF receptacles incorporate lock-out functionality to protect against mis-wired line-load connections and dam-age the AFCI/GFCI circuitry.ApplicationsT able 5. AF/GF status indicatorTest indicator Red LED Test indicator Amber LED Rest button status DiagnosisActionOFF OFF In"Device is functioning properlyOR branch circuit may have no power"Manually press the TEST button to trip the device. Amber light should come ON • If Amber light does not come ON, check if there is power to the branch• If Amber light does come ON, manually press the RESET button to restore power the the device • If AF/GF receptacle does NOT reset, replace AF/GF receptacle• If AF/GF receptacle receptacle does reset, device is functioning properly OFF ON Out Device is in tripped state (either from manually pressing TEST button or from GFCI trip)Manually press the RESET button to restore power to the device • If AF/GF receptacle does not reset, replace the AF/GF receptacleOFF 2 Blinks Out GENERAL SERIES ARC Manually press the RESET button to restore power to the device• If AF/GF receptacle continues to trip, contact an electrician to locate and repair the low current arc faultOFF 3 Blinks Out PARALLEL ARC Manually press the RESET button to restore power to the device• If AF/GF receptacle continues to trip, contact an electrician to locate and repair the parallel arc fault OFF 4 Blinks Out OVERVOLTAGE Manually press the RESET button to restore power to the device• If AF/GF receptacle continues to trip, contact an electrician to locate and repair the overvoltage conditionOFF 5 Blinks Out AFCI self-test failure Manually press the RESET button to restore power to the device• If it does not reset and/or the blinking continues, replace the AF/GF receptacle BlinkingON or OFFIn or OutGFCI self-test failureManually press the RESET button to restore power to the device• If it does not reset and/or the blinking continues, replace the AF/GF receptacleTechnical DataEffective May 2016AFGFDuplex ReceptacleProject Name:Prepared By:Project Number:Date:Catalog Number:Type:Product dimensionsFigure 1. OBC TRAFGF 15A Line art with dimensionsFigure 2. OBC TRAFGF 20A Line art with dimensionsCertifications & compliancesKEY:cULusNOMTRAFGA20••Electrical Sector 203 Cooper CirclePeachtree City, GA 30269United States /wiringdevicesElectrical Sector Mexico Operations Carr. Tlalnepantla -Cuautitlan Km 17.8 s/n Col. Villa Jardin esq.Cerrada 8 de MayoCuautitlan, Mexico CP 54800Mexico Eaton.mx/wiringdevices Eaton is a registered trademark. All other trademarks are property of their respective owners.Eaton1000 Eaton Boulevard Cleveland, OH 44122United States Electrical Sector Canada Operations 5925 McLaughlin RoadMississauga, Ontario, L5R 1B8CanadaEatonCanada.ca/wiringdevices© 2016 EatonAll Rights Reserved Printed in USAPublication No. TD610028EN May 2016。
德力西 CDW3万能式断路器 说明书
1600AF 4000AF 1000AF0060051600AF1000AF2000AF3200AF4000AF6300AF2500AF锁定、联锁和保护类附件:合分闸按钮罩盖、机械联锁、钥匙锁、门联锁、安全挡板锁指示类附件:准备合闸触点、三位置信号触点、故障指示触点、辅助触点操作类附件:分合闸线圈、欠压线圈、电动操作机构、电气复位电路保护类附件:N相外接互感器、接地互感器、漏电互感器连接类附件:水平、垂直、扩展排、加长排■附件■智能脱扣器iTR326iTR326AiTR326HCDW3系列万能式断路器的额定电流自400A至6300A,额定电压交流220V/230V/240V/380V/400V/415V/440V/480V/500V/525V/550V/660V/690V,适用于交流50/60Hz,主要用于配电网络中,用来分配电能,保护线路和电源设备,使之免受过载,欠电压,短路,单相接地等故障的危害。
该断路器能广泛适用于电站、工厂、矿山和现代高层建筑,特别是在智能楼宇中的配电系统。
符合标准:GB/T14048.2 IEC/EN 60947-2■适用范围■正常工作条件ON1分闸按钮(O)2合闸按钮(I)3储能机构状态指示器贮能,允许合闸4主触头位置指示器分闸合闸5机械储能手柄6控制器7摇进(出)装置8连接,试验及分离位置指示9连接,试验及分离位置限位器10摇杆存放处■认识正面■ 主要参数008 007CDW3 默认标准配置附件:分励,合闸,电操,4开4闭辅助触头,门框,相间隔板, 电源模块,iTR326A 6300AF无固定式,6300AF-6300A只有3P抽屉式■ 本体编码■ 附件编码010 009注:CDW3ATSEC2标配导线为2米,CDW3ATSECM标配导线为4米(适用于三相四线产品,控制回路电压AC230V/AC380V),每增加一米另外收费。
制定机械联锁三台需要提前与厂家沟通。
012011注(1*):客户购买选配型附件时请联系制造商进行沟通注(2*):2000AF /2500AF /3200AF /6300AF 二次接线端子防护罩搭配二次端子座47回路使用,如需用于51回路请联系制造厂商。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
DPT-2W3分布式微机变压器综合保护装置_________________________________________技术和使用说明书南京恒星自动化设备有限公司SUN NANJING AUTOMATION EQUIPMENT CO.,LTD南京恒星自动化设备有限公司版权所有2005.04(V1.0)本说明书适用于DPT-2W3保护装置,V1.00版本本说明书和产品今后可能会有小的改动,请核对实际产品与说明书的版本是否相符。
目录1.概述 (4)1.1 DP系列产品概述 (4)1.2 应用范围 (4)1.3 保护配置 (4)1.4性能特征 (5)1.5规范性引用文件 (5)2.技术条件 (6)2.1环境条件 (6)2.2电源 (7)2.3 交流回路 (7)2.4过载能力 (7)2.5装置的主要功能 (8)2.6主要技术性能指标 (8)2.7测量元件 (10)3.工作原理 (10)3.1.差动电流与制动电流 (10)3.2. 差动速断继电器: (12)3.3. 比例差动继电器 (12)3.4. 定时限过流保护 (13)3.5. 功率继电器 (13)3.6. 零序过压继电器 (14)3.7. 过励磁继电器 (14)3.8. 过负荷继电器 (15)3.9.过温及瓦斯继电器 (15)3.10 主要逻辑回路 (15)4.辅助功能 (16)4.1定值组切换 (16)4.2 测量 (16)4.3 对开关的控制 (17)4.4 事故记录 (17)4.5 故障录波 (17)4.6 事件记录 (17)5.面板及操作 (18)5.1面板说明 (18)5.1.1面板图 (18)5.1.2面板按键说明 (18)5.1.3指示灯说明 (19)5.1.4操作箱的使用 (19)5.2键盘操作 (19)5.3界面内容 (19)5.3.1默认界面 (19)5.3.2目录界面 (19)5.3.3监测界面 (20)5.3.4系统界面 (20)5.3.5控制界面 (20)5.3.6整定界面 (20)5.3.7设置界面 (20)5.3.8记录界面 (21)5.3.9校准界面及调试界面 (21)5.3.10重要数据浏览界面 (21)6. 安装与对外接线 (21)6.1 开箱与安装 (21)6.1.1 开箱和包装 (21)6.1.2 安装现场要求 (21)6.1.3 安装尺寸 (22)6.1.4 保护和系统接地 (22)6.2 连接 (24)6.2.1 连接测量和辅助回路 (24)6.2.2 连接电源 (24)6.2.3 连接开关量输入 (24)6.2.4 连接通讯口1 (24)6.2.5 连接亮屏控制 (24)6.2.6 面板LED平面发光管的使用 (25)附录一.信息表 (26)附录二.DPT-2W3保护装置逻辑框图 (39)附录三.DPT-2W3保护装置开出原理图 (39)附录四.DPT-2W3保护装置对外接线原理图 (39)DPT-2W3型分布式微机变压器综合保护装置1.概述1.1 DP系列产品概述DP系列的保护在开发时借鉴了当前国内外同类产品的成熟经验,并根据我国电力系统运行的实际要求,以及数字式保护今后的发展趋势,在制定设计方案时要求做到:●满足变电站综合自动化的要求,有按标准规约制定的网络接口,所有保护的运行数据能够在数据总线上交流,配合监控软件可以组成变电站自动化系统。
●保护原理先进,配置合理、完善,既能满足大网的运行要求,也能适应小网特别是小水电网的要求。
●结构可靠密封好,具有良好的抗干扰和防尘能力。
●减小安装尺寸,分布式安装时可直接装于开关柜上,集中组屏时可减少屏数,降低造价。
使用与操作简单,适应低电压等级运行人员的技术水平。
●装置的核心部件(CPU)采用了处理能力强的32位系统,替代了以往2~3个CPU才能实现的功能,大大提高装置的可靠性。
●对于交流信号处理电路,转换精度为16位,最高采样速度可达250KHz/s,大大提高了系统数据的采集精度和加速了数据采集。
●整个系统基于嵌入式系统的技术,采用C语言和汇编语言混合编程,以由硬件驱动程序实时多任务操作系统,数据服务三部分组成的实时软件平台技术为基础,保证了产品功能的高可靠性、灵活配置、可移植性。
●采用新的交流采样快速算法,不仅计算简单、速度快、精度高,同时可完全滤清暂态超越时产生的衰减非周期分量及奇次谐波分量,极大地提高了滤波能力,特别适合于需要快速动作的继电保护。
1.2 应用范围DPT-2W3型分布式微机变压器综合保护装置是DP系列数字式保护中的一种,可独立构成35KV变压器完整的保护。
1.3 保护配置装置由以下主要保护回路构成:a. 差动速断保护;b. 比例差动保护;c. 两侧两段三相式定时限过流保护,其中一侧可以带复合电压闭锁及方向;d. 零序过电压闭保护;e. 过负荷保护;f. 过励磁保护g. 瓦斯及过温保护装置还包括以下主要逻辑回路:a.装置整组启动回路;b.CT断线闭锁回路;c.二次谐波闭锁回路1.4性能特征●动作速度快,速断故障跳闸时间<35ms。
●交流采样算法速度快,精度高并可完全滤除非周期分量。
●硬件上采取了全封闭机箱,结构可靠密封好,具有良好的抗干扰和防尘能力。
●事故报文,可保存最新的16条故障数据,7次故障录波报文,以及1024次最新的装置操作记录。
●此保护可采用分布式安装,简化接线。
具有良好的中文人机交互界面,可通过面板整定定值。
●具备遥测功能,正常运行时能够上报各种运行参数,故障时能够记录并上报所有故障数据。
●可以接入脉冲电度表的计数脉冲。
●对开关有就地和远方的控制功能。
●对跳、合闸回路接线的状态有在线监视功能。
●灵活的通信方式,配有RS-485和以太网接口。
1.5规范性引用文件下列文件中的条款通过在本标准的引用而成为本标准的条款。
凡是注日期的引用文件,其随后所有的修改单(不包括勘误的内容)或修订版均不适用于本标准,然而,鼓励根据本标准达成协议的各方研究是否可使用这些文件的最新版本。
凡是不注日期的引用文件,其最新版本适用于本标准。
GB 9361-1988 计算站场地安全要求GB 16836-1997 量度继电器和保护装置安全设计的一般要求GB/T 191-2000 包装储运图示标志(eqv ISO 780:1997)GB/T2887-2000 电子计算机场地通用规范GB/T3047.4-1986 高度进制为44.45mm的面板、架和柜的基本尺寸系列GB 4208-1993 外壳防护等级(IP代码)(eqv IEC 529:1989)GB/T7261-2000 继电器及装置基本试验方法GB/T8367-1987 量度继电器直流辅助激励量的中断与交流分量(纹波)(eqv IEC60255-11:1979)GB/T11287-2000 电器继电器第21部分:量度继电器和保护装置的振动、冲击与碰撞和地震试验第1篇:振动试验(正玄)(idt IEC60255-21-1:1988)GB/T14537-1993 量度继电器和保护装置的冲击与碰撞试验(eqv IEC 60255-21-2:1988)GB/T14598.3-1993 电气继电器第5部分:电气继电器的绝缘试验(eqv IEC 60255-5:1977)GB/T14598.9-2002 电器继电器第22部分:量度继电器和保护装置的电气干扰试验第三篇:辐射电磁场干扰试验(Idt IEC 60255-22-3:1989)GB/T14598.10-1996 电器继电器第22部分:量度继电器和保护装置的电气干扰试验第4篇:快速瞬变干扰试验(Idt IEC 60255-22-4:1992)GB/T14598.13-1998 电器继电器第22部分:量度继电器和保护装置的电气干扰试验第1篇:1MHz脉冲干扰试验(eqv IEC 60255-22-1:1988)GB/T14598.14-1998 电器继电器第22部分:量度继电器和保护装置的电气干扰试验第2篇:静电放电试验(Idt IEC 60255-22-2:1996)GB/T 17626.5-1999 电磁兼容试验和测量技术浪涌(冲击)抗扰度试验(idt IEC61000-4-5:1995)JB/T7828-1995 继电器及装置包装储运技术条件GB/T13729-2002 远动终端设备DL/T630-1997 交流采样远动终端技术条件GB/T 17626.8-1998 电磁兼容试验和测量技术工频磁场抗扰度试验(idtIEC61000-4-8:1993)DL/T478-2001 静态继电保护及安全自动装置通用技术条件GB/T2900.49-1994 电工术语电力系统保护(eqv IEC60010(448):1987)GB/T17742-1999 中国地震烈度表GB/T14598.16-2002 电气继电器第25部分:量度继电器和保护装置的电磁发射试验(IEC 60255-25:2000,IDT)GB/T 17626.6-1998 电磁兼容试验和测量技术射频场的传导骚扰抗扰度试验GB/T 17626.9-1998 电磁兼容试验和测量技术脉冲磁场抗扰度试验(idt IEC61000-4-9:1993)GB/T17626.10-1998 电磁兼容试验和测量技术阻尼振荡磁场抗扰度试验(idtIEC61000-4-10:1993)GB/T17626.11-1999 电磁兼容试验和测量技术电压暂降、短时中断和电压变化抗扰度试验IEC60255-22-7:2003 电气继电器第22-7部分:量度继电器和保护装置的电气骚扰试验—工频抗扰度试验IEC 60255-5:2000 电气继电器第5部分:量度继电器和保护装置的绝缘配合要求和试验.2.技术条件2.1环境条件2.1.1 正常工作的大气条件a)环境温度:-20℃~+55℃;b)相对湿度:≤90%(相对湿度为90%时,环境温度不低于25℃,继电器内无凝结及冰形成);c)大气压力 86kPa~106kPa2.1.2 试验的标准大气条件a)环境温度:+15℃~35℃;b)相对湿度:45%~75%;c)大气压力:86kPa~106kPa.2.1.3 仲裁试验的标准大气条件:a)环境温度:+20℃±2℃。
b)相对湿度:45%~75%。
c)大气压力:86kPa~106kPa.2.1.4 储存、运输极限环境温度:-25℃~+70℃2.1.5 周围环境a)不允许有超过2.11规定的电磁干扰存在.b)场地应符合GB 9361-1988中B类安全要求的规定.c)使用地点不出现超过GB/T11287-2000规定的严酷等级为1级的振动;不发生超过GB/T17742-1999规定的烈度为ⅤⅡ度的地震。