United Metal Products
1920 E Broadway Road Tempe, AZ 85282
WITHOUT FILTERS WITH FILTERS
FAN HP FAN HP FAN HP FAN HP FAN HP FAN HP FAN HP Amps Amps DWDI FC 32153215322032203220322532254750DWDI BI 40104015401540154015402040203940DWDI AF 40154015402040203940DWDI FC 40154015402040204020402540254750DWDI BI 40154015402040204020402540254750DWDI AF 40254750DWDI FC 40204020402540254025403040305560DWDI BI 40204020402540254025403040305560DWDI AF DWDI FC 40254025403040304040404040407080DWDI BI 40304030403040404040404040407080DWDI AF 36303630364036403640364036407080DWDI FC 4040404040504050405040504060101125DWDI BI 4050405040504050405040603675117125DWDI AF 40304040404040404040405040508690DWDI FC DWDI BI 49404940494049504950495049508690DWDI AF 49404940494049404940495049508690DWDI FC DWDI BI 4950496049604960497549754975117125DWDI AF
49
50
49
50
49
50
49
60
49
60
49
60
49
60
102
125
0.50CEL-ODO-60 30,000 cfm Power
Requirements (at 460/3/60) *
MCA MOP 1.00 1.25 1.50CEL-ODO-140 70,000 cfm CEL-ODO-72 36,000 cfm CEL-ODO-84 42,000 cfm CEL-ODO-96 48,000 cfm CEL-ODO-112 56,000 cfm MODEL # Air Volume 0.000.25 1.500.75CEL-ODO-160 80,000 cfm
1.75DOUBLE INLET / SINGLE FAN - EXTERNAL STATIC PRESSURE ("WG)
0.250.500.75 1.00 1.25* Unit power requirements, dimensions and weights are given as a guide. They include down discharge AF fans and the largest motor HP shown. Motors are standard efficiency single speed ODP.
* Different fan or motor types, fan orientation or motor position will effect dimensions and weights. Full details will be given with any quotation.
* All these units can operate at higher static pressures with fan or motor changes. Please contact the factory with your requirements.* Data is based on the maximum output of each unit size. Intermediate volumes will be achieved by reducing the fan speed.* Data shown is based at sea level. HP and performance may be effected at high altitudes.
* The filter is an option. When adding filters, add the filter pressure drop to the unit ESP and use that total to select the motor HP.* Please specify the fan discharge location (Up, Down or End) when ordering these units.
Ship Operate """""""lb lb DWDI FC 10293182623.939.739.771.271.231.65,2756,225DWDI BI 10293182627.049.949.966.166.134.85,5756,550DWDI AF 10293182627.049.949.966.166.134.85,5506,500DWDI FC 10796182627.049.949.966.166.134.85,8006,800DWDI BI 10796182627.049.949.966.166.134.85,9006,925DWDI AF 10796182627.049.949.966.166.134.85,9256,925DWDI FC 10796182627.049.949.966.166.134.85,8757,050DWDI BI 10796182627.049.949.966.166.134.85,9757,125DWDI AF DWDI FC 11096182627.049.949.966.166.134.86,0757,400DWDI BI 11096182627.049.949.966.166.134.86,1507,475DWDI AF 11096182635.251.838.765.165.137.26,8508,175DWDI FC 114108192627.049.949.971.171.136.86,9008,275DWDI BI 114108192626.149.949.971.171.135.96,8008,200DWDI AF 114108192638.057.242.667.467.446.77,7759,150DWDI FC DWDI BI 132112209645.169.451.969.869.852.79,55011,250DWDI AF 132112209645.169.451.969.869.852.79,55011,250DWDI FC DWDI BI 133120209645.169.451.969.869.852.710,05011,825DWDI AF
133
120
209
6
45.1
69.4
51.9
69.8
69.8
52.7
9,925
11,700
CEL-ODO-160 80,000 cfm
MODEL # Air Volume CEL-ODO-60 30,000 cfm CEL-ODO-72 36,000 cfm FAN
QTY & TYPE CEL-ODO-112 56,000 cfm CEL-ODO-140 70,000 cfm E2F CEL-ODO-84 42,000 cfm CEL-ODO-96 48,000 cfm LENGTH With Clean Filters
WIDTH
B C D E1A HEIGHT WEIGHTS
DOUBLE INLET / SINGLE FAN - EVAPORATIVE COOLER DIMENSIONS - See Drawing
* Unit height shown above includes the standing roof seam.
* Allow a minimum service clearance of 36” in front of all access doors and air inlet louvers.
* We recommend a minimum incoming water line pressure of 50 psi. Under no circumstances should the incoming water line pressure exceed 125psi.
* Standard Evaporative Media access panels require (2) persons to lift on units over 72” high. Consider upgrading to hinged access doors on tall units.
* Due to continued product development, all data is subject to change without notice. Full details will be provided with submittals.
OUTSIDE CURB DIMENSIONS
Deduct 5.0” from the O.D. of the baseframe to obtain the O.D. of the roof curb. Please check submittal drawings to verify exact O.D. of the base-frame before the roof curb is built.。