核电厂稳压器电加热器异常经验反馈
张斌;邹国强;党恒军;刘旺瑛
【期刊名称】《中国核电》
【年(卷),期】2015(008)003
【摘要】It is critical that the electrical heater of the pressurizer works normally for PWR. Based on analyses for the heater failure events in a new nuclear power plant and combined with the heater manufacturing and installation process and related engineering test, some im-portant parameters, including filler temperature limits of no more than 140℃, and thermal ageing principle, are found out. It is helpful for providing advices and experience feedback for the usage and maintenance of heaters, and having some instructive meanings for the safe oper-ation of nuclear power plant.%运行核电厂稳压器电加热器能否正常工作直接关系到核电厂的安全运行.通过对某新建核电厂调试期间稳压器电加热器故障事件进行剖析,结合电加热器制造安装工艺和工程试验验证,得出了该型号电加热器填充物的使用温度限值(140 ℃).采用加速失效思想设计了预计电加热器寿命的试验,找到了电加热器热老化的相关规律.根据电加热器填充物使用温度限值和热老化规律,给出了电加热器使用保养建议和处理类似事件的经验反馈,对核电厂的安全运行有一定的指导意义.
【总页数】6页(P239-244)
【作者】张斌;邹国强;党恒军;刘旺瑛
【作者单位】西安核设备有限公司, 陕西西安 710021;中广核工程有限公司, 广东深圳 518114;西安核设备有限公司, 陕西西安 710021;西安核设备有限公司, 陕西西安 710021
【正文语种】中文
【中图分类】TM623
【相关文献】
1.核电厂稳压器电加热器在役更换自动焊接技术 [J], 陈英杰;颜少华;王松;陈忠兵;刘超;成鹏;冯兴旺
2.核电厂稳压器SEBIM安全阀自主化检修经验反馈 [J], 邓冬;张发云;赵立彬;吕艳新;石红
3.在役核电厂稳压器电加热器更换技术的工艺改进与应用 [J], 闫永巍;郑孝纲
4.压水堆核电厂稳压器电加热器焊接工艺研究 [J], 康文捷;杨晓波
5.核电厂稳压器电加热器典型故障分析及改进措施 [J], 尚强;冯宁;张敏
因版权原因,仅展示原文概要,查看原文内容请购买。