轻型井点降水法工程量的计算及如何套定额(工程科)
轻型井点降水方案
轻型井点降水施工方案XX工程公司年月日目录一、工程概况···································································2二、编制依据····································································2三、降水方案选择·······························································2四、井点降水相关计算·························································3五、主要降水设备·······························································6六、施工工期·····································································7七、井点施工方法·······························································7八、质量标准及质量保证措施················································8九、危险点分析································································10十、安全生产及文明施工措施···············································10 十一、环保措施································································11一、工程概况本期设计为2×600MW亚临界汽轮发电机组。
轻型井点降水计算
长30m 宽25m 深5m 长/宽=1.226m 23.5m 15m 5m/d 水位降低值S 3.5m 30m 降水深度S’ 4.75m管的埋置深度H≥H 1+h+iL+l= 5.75m其中:2.51.012.50.116.05m其中:无压完整井Q=1.366K(2H-S)S/(lgR-lgr)=其中:Q:单井涌水量(m3/d)K:渗透系数(m/d)H:含水层厚度(m)R:抽水影响半径(m)R=1.95S(HK)1/2=S:水位降低值(m)r:井点的半径(m)群井井点(环形井点系统)涌水量Q=1.366K(2H-S)S/(lgR-lgx0)=其中:x0:基坑的假想半径x0=(A/π)1/2=无压非完整井Q=1.366K(2H 0-S)S/(lgR-lgx 0)=836.54m 3/天其中:K:渗透系数(m/d)H 0:抽水影响深度(m)H0=1.85(S'+l)=10.64m轻型井点降水计算 KF002一、计算参数基坑平面尺寸地下水深渗透系数K 2、井点型式的确定地下水位基坑底部高程l:滤水管长度1、井点管的长度井点管的长度=H+0.3=0.2-0.3:井点管露出地面高度H 1:井点管埋设面至基坑底面的距离h:基坑中央最深挖掘面至降水曲线最高点的安全距离L:井点管中心至基坑中心短边距离3、基坑总涌水量计算H:井点管的埋置深度含水层厚度i:降水曲线坡度,与土的渗透系数、地下水流量等因素有关二、计算mmmm其中:S':降水深度(m)l:滤管长度(m)。
轻型井点降水的施工方案
轻型井点降水的施工方案一、轻型井点降水介绍沿基坑四周每隔肯定间距布设井点管,井点管底部设置滤水管插入透水层,上部接软管与集水总管进行连接,集水总管为Φ150钢管,周身设置与井点管间距相同的Φ40吸水管口,然后通过真空吸水泵将集水管内水抽出,从而达到降低基坑四周地下水位的效果,保证了基底的干燥无水。
水井大致分为四大类,无压完整井、无压非完整井、承压完整井、承压非完整井。
二、适用范围适用于渗透系数为0.1~50m/d的土层中。
降水深度为:单级井点3~6m,多级井点6~12m三、基坑涌水量计算计算公式:式中:Q基:基坑基本排水量K:粘土层渗透系数,K=0.10m/d。
四、井点计算式中:q——单井出水本领(m3/d)r0——过滤管半径=0.025ml——滤管进水部分长度=2m井点数及井距采纳公式:井数:n=1.1Q/q根平均井间距b=L*m/n式中:L——基坑周长n——井点根数五、井点降水工艺及技术措施降水井成孔采纳冲孔机械成孔,但由于冲击成孔效率较低,先由人工先清理块石层障碍,再布置冲击钻机进场。
1、管井成孔工艺场地平整→井位放线→人工清理块石障碍→复核桩位→开挖浆池、浆沟→护筒埋设→桩机就位、孔位校正→冲击造孔、泥浆循环、清除废浆、泥渣→终孔验收→下滤水井管和填充砂砾。
2、降水运行(1)可采纳分次降水,即边抽水边进行土方开挖,以使水位缓缓平稳下降,因猛烈水位下降会加添沉降量,避开导致相邻建筑物及道路损坏。
(2)严禁挖土机、吊车等设备撞击降水管、排水管线、电缆等。
(3)降水要保证昼夜连续运转,防止因停泵使水位上升,造成“涌槽”事故,现场要配备备用电源(现场配备2台300KW发电机组)。
(4)设多个闸箱,单闸单箱单机。
(5)专人巡查,发觉停泵,立刻处理。
(6)降水结束需缓慢稳定抬升水位必具备两个条件:一是建筑物基础工程必需施工完毕,二是建筑物荷载大于地下水上顶托力,充足抗浮设计要求。
3、降水动态观测(l)降水开始后即对地下水位进行全面的观测记录,以便随时获得水位降落信息。
山东轻型井点降水定额明细
山东轻型井点降水定额明细
山东省的轻型井点降水定额明细,具体包括以下内容:
1. 降水量:根据地区气候特点和降水需求,确定每个轻型井点的降水量。
一般会考虑地区的降水量历史数据、农作物的生长需水量等因素。
2. 降水方式:确定每个轻型井点的降水方式,包括雨水、灌溉水和融雪水等不同来源的降水。
3. 降水频次:确定每个轻型井点的降水频次,即降水的时间间隔和持续时间。
根据农作物的生长周期和需水特点,确定不同时期的降水频次。
4. 降水技术:确定每个轻型井点的降水技术,包括喷洒、滴灌、漫灌等不同方式的降水技术。
根据地区的土壤特点、水源条件和农作物需水特点,选择合适的降水技术。
5. 降水设备:确定每个轻型井点的降水设备,包括喷灌设备、滴灌设备、阀门和管道等。
根据地区的水资源情况和灌溉需求,选择合适的降水设备。
以上是山东省轻型井点降水定额的一般明细,具体的内容和数据可能会根据地区的实际情况和政策要求有所不同。
轻型井点降水水量计算公式
轻型井点降水水量计算公式轻型井点降水水量计算公式是用来计算轻型井点降水水量的数学公式。
轻型井点降水是指在短时间内,降水量较大但降水时间较短的降水现象,通常会导致城市内涝和山洪灾害。
因此,对于轻型井点降水的水量进行准确的计算和预测非常重要。
轻型井点降水水量计算公式通常包括降水强度、降水时间和降水面积等参数。
一般来说,轻型井点降水水量计算公式可以分为两种情况,一种是在没有降水记录的情况下,根据气象数据和地理信息来估算轻型井点降水水量;另一种是在已经有降水记录的情况下,根据实测数据来计算轻型井点降水水量。
在没有降水记录的情况下,可以使用以下的轻型井点降水水量计算公式:Q = P × A。
其中,Q代表降水水量,单位为立方米;P代表降水强度,单位为毫米/小时;A代表降水面积,单位为平方千米。
在已经有降水记录的情况下,可以使用以下的轻型井点降水水量计算公式:Q = P × T × A。
其中,Q代表降水水量,单位为立方米;P代表降水强度,单位为毫米/小时;T代表降水时间,单位为小时;A代表降水面积,单位为平方千米。
通过以上的轻型井点降水水量计算公式,我们可以比较准确地计算出轻型井点降水的水量。
在实际应用中,我们可以根据气象数据和地理信息来估算轻型井点降水水量,也可以根据实测数据来计算轻型井点降水水量。
这些计算结果对于城市防汛和山洪灾害的防治具有重要的意义。
除了轻型井点降水水量计算公式外,还有一些其他的因素也需要考虑。
例如,地表的渗透能力、排水系统的状况、地形地势等因素都会影响轻型井点降水的水量。
因此,在实际应用中,我们还需要综合考虑这些因素,才能更加准确地预测和计算轻型井点降水的水量。
总之,轻型井点降水水量计算公式是一个非常重要的工具,可以帮助我们准确地计算和预测轻型井点降水的水量。
通过合理地应用这些计算公式,我们可以更好地预防和应对城市内涝和山洪灾害,保障人民生命财产的安全。
希望未来能够进一步完善和改进轻型井点降水水量计算公式,为城市防汛和山洪灾害的防治提供更加可靠的技术支持。
轻型井点降水计算
一பைடு நூலகம்计算参数
基坑平面尺寸
长
m
宽
m
深
m
长/宽=
地下水深
m
渗透系数
含水层厚度
m
降水深度
m
二、计算
1、井点管的长度
H≥H1+h+iL+l=
m
其中: H:井点管的埋置深度
H1:井点管埋设面至基坑底面的距离
h:基坑中央最深挖掘面至降水曲线最高点的安全距离
1.0
L:井点管中心至基坑中心短边距离
i:降水曲线坡度,与土的渗透系数、地下水流量等因素有关
l:滤水管长度
井点管的长度=H+0.5l+0.3=
其中: 0.2-0.3:井点管露出地面高度
2、井点型式的确定
3、基坑总涌水量计算 无压完整井
Q=1.366K(2H-S)S/(lgR-lgr)= 其中: Q:单井涌水量(m3/d)
K:渗透系数(m/d) H:含水层厚度(m) R:抽水影响半径(m)
R=1.95S(HK)1/2= S:水位降低值(m) r:井点的半径(m) 群井井点(环形井点系统)涌水量 Q=1.366K(2H-S)S/(lgR-lgx0)= 其中: x0:基坑的假想半径 x0=(A/π )1/2=
无压非完整井 Q=1.366K(2H0-S)S/(lgR-lgx0)=
轻型井点降水计算
轻型井点降水计算 KF002
一、计算参数
基坑平面尺寸
长
m
宽
m
深
m
长/宽=
地下水深
m
渗透系数
含ห้องสมุดไป่ตู้层厚度
m
降水深度
m
二、计算
1、井点管的长度
H≥H1+h+iL+l=
3、基坑总涌水量计算 无压完整井
Q=1.366K(2H-S)S/(lgR-lgr)= 其中: Q:单井涌水量(m3/d)
K:渗透系数(m/d) H:含水层厚度(m) R:抽水影响半径(m)
R=1.95S(HK)1/2= S:水位降低值(m) r:井点的半径(m) 群井井点(环形井点系统)涌水量 Q=1.366K(2H-S)S/(lgR-lgx0)= 其中: x0:基坑的假想半径 x0=(A/π )1/2=
m
其中: H:井点管的埋置深度
H1:井点管埋设面至基坑底面的距离
h:基坑中央最深挖掘面至降水曲线最高点的安全距离
1.0
L:井点管中心至基坑中心短边距离
i:降水曲线坡度,与土的渗透系数、地下水流量等因素有关
l:滤水管长度
井点管的长度=H+0.5l+0.3=
其中: 0.2-0.3:井点管露出地面高度
2、井点型式的确定
无压非完整井 Q=1.366K(2H0-S)S/(lgR-lgx0)=
井点降水工程量怎么计算?
井点降水工程量怎么计算?井点降水工程量的计算依据是你的降水施工组织设计。
在施工组织设计中,应明确井点降水的方式、井点管的部署地址及数量、井点管深度、使用天数等。
若井管间距施工组织设计没有规定时,可按轻型井点管距,喷射井点管距2-3m确定。
1、制作工程量。
电渗井点阳极制作工程量以“根”计算。
其他井点管,已在安装和使用综合基价中以摊销量或一次使用量计入,不另计算制作花销。
2、安装工程量。
安装工程量,除水泥管井井点按井深以“延长米”计算外,其他均按“根”计算工程量。
3、拆掉工程量。
轻型井点、发射井点、大口径井、电渗井点阳极、水平井点等的拆掉工程量,均以“根”计算。
水泥管井井点管花销已在安装综合基价受骗入,不考虑拆掉。
4、使用工程量。
使用工程量,按套数乘以使用天数,以“套×天”计算。
(1)井点套的确定:轻型井点,以50 根为一套;发射井点及电渗井点阳极,以30根为一套;大口径井点,以 45 根为一套;水平井点,以 10 根为一套;水泥管井井点,以每一管井(即一个“井点”)为一套。
总根数不足一套时,可按一套计算。
(2 )井点管使用天数的确定:使用天以每 24h 为一天。
使用天数应按施工组织设计规定的使用天数计算。
依据施工组织设计、办理好经济签证、按计算规则计算工程量。
如何差异轻型井点与深井井点第一判断可否采用轻型井点依据两个参数,一是土的渗透系数是否在0.1-50m/d,二是降低水位深度是否在3-6米之间或根据井点级数确定;一般采用离心泵与潜水泵。
深井井点具有排水量大,降水深( 15 ~ 50m )、不受土质限制等特点,适用于地下水丰富,基坑深(> 10m ),基坑占地面积大的工程地下降水;流砂地区和重复挖方地区使用这种方法,收效更佳。
一般采用电动机在上面的深井泵及深井潜水泵。
山东轻型井点降水定额明细
山东轻型井点降水定额明细摘要:一、山东轻型井点降水定额明细概述二、山东轻型井点降水定额明细的具体内容三、山东轻型井点降水定额明细的实施与影响正文:一、山东轻型井点降水定额明细概述山东轻型井点降水定额明细是我国山东省针对地下水资源管理、合理开发利用和保护的一项重要措施。
近年来,随着地下水资源的过度开采,导致部分地区地下水位持续下降,引发了生态环境、农业生产和城市供水等方面的问题。
为了解决这些问题,山东轻型井点降水定额明细应运而生,旨在加强地下水资源的管理和保护,促进水资源的可持续发展。
二、山东轻型井点降水定额明细的具体内容山东轻型井点降水定额明细主要包括以下几个方面:1.降水井布置:根据地下水位、地质条件和用水需求等因素,科学合理地布置降水井,确保降水效果达到预期目标。
2.降水设备选型:根据降水井的深度、地下水位和地质条件等因素,选择合适的降水设备,以保证降水效果和设备运行的安全性。
3.降水定额标准:根据地下水资源的类型、用途和开发强度等因素,制定合理的降水定额标准,以实现地下水资源的有效保护和合理利用。
4.降水监测与评价:建立降水监测系统,对降水过程进行实时监测和数据分析,评价降水效果和地下水资源的变化趋势,为政策制定和调整提供科学依据。
三、山东轻型井点降水定额明细的实施与影响山东轻型井点降水定额明细的实施,对于地下水资源的保护和利用具有重要意义。
一方面,通过降水定额管理,可以有效控制地下水的开采量,避免过度开采导致的地下水位下降和生态环境恶化等问题;另一方面,降水定额管理有助于提高水资源利用效率,促进水资源的合理配置和优化利用。
总之,山东轻型井点降水定额明细的实施,有利于实现地下水资源的有效保护和合理利用,促进我国水资源的可持续发展。
轻型井点降水方案及计算
轻型井点降水条件:井点抽水量必须大于场地范围的涌水量才能达到降水目的1.涌水量计算根据地下水位是否有压力,水井分为无压井和承压井.根据水井是否达到不透水层,分为完成井和非完成井.(只有无压完成井比较完善)1.环形井点(1).无压完成井的涌水量计算Q=1.366K【(2H-S)S/lgR-lgX.】K=地下水穿透土层的系数,单位 M/dH=含水层的厚度(原有地下水位到不透水层)s=水位降低值(原有地下水位倒降低后水位)R=抽水影响半径;R=1.95s√HK(√为开方)X。
=整个降水系统假想半径 X。
=√f/π (f为井点面积)(2)无压非完整井(仍用上述公式,只是将H换成地下水有效深度H。
)计算出的H。
必须与实际含水层厚度H相比较当H。
>H时依然取H(3)承压完整井计算公式Q=[2.73K(M×N)÷(lgR-lgX)]×[√M÷(L+0.5)r]×√(2M-L)÷MM=上层不透水层至下层不透水层r=井点管半径(4)承压非完整井计算公式Q=2.73K×M×S ÷(lgR-lgX。
)2.单根井点管水量计算q=65πdl(k) [l=滤管长度. d=井管直径将k开三次方]3.井点管数量及距离的计算(D可取0.8 1.6 1.2 2.0)数量n=1.1(Q÷q)距离D=L÷n(L为总管总长)D是否符合管上间距要求、对比取出管上间距再次求井管数量4.设备选择采用干式真空泵井点设备.型号W5.W6W5:L<100m数量<80根W6:L<120m数量<100根在系统使用过程中.经常检查真空表;压力表始终≥55KPa。
轻型井点降水计算
For personal use only in study and research; not for commercial useFor personal use only in study and research; not for commercial use举个例子:井点降水计算目前该工程基础处于春季施工,属于多雨季节,地下水位较高,根据《地质报告》提供,场地地下水位埋深在自然地面-1.5m以下,基础最大开挖深度3.55m。
根据《地质勘察报告》提供的地质情况及基础设计施工的要求,为确保施工质量及工程顺利进行,采用一级井点降水配合基础施工。
按照《建筑基坑边坡支护技术规程》和《施工规范》的要求对建筑物基坑涌水量计算。
1、涌水量的计算按《建筑基坑边坡支护技术规程》附录F2-1、F07。
A、39#楼基坑一级井点涌水量的计算:H2-hm2涌水量Q=1.366Klg(1+R/r0)+lg(1+0.2 hm/ r0)(hm-l)/la、根据《地质报告》提供的○3层渗透系数K=5.2×10-4cm/s。
按《市政岩土规范》取粉砂渗透系数:K=1.0m/db、抽水影响深度H0的计算:S‘=SA+L S‘为井点支管埋深地下水位至井点支管滤口上口的长度。
SA支管长度5.0m,L滤管长度1m,井点支付全长6m。
S‘=5.0m-0.2m+1m=5.8mS‘/ S‘+L=4.8/4.8+1=0.83根据计算,查《建筑施工手册》第二版上P879,H0值表查表得系数1.85H0=1.85(S‘+L)=1.85×(4.8+1)=10.73mc、含水层厚度的计算H:根据场地土层,场地无隔水底板含水层厚度取抽水影响深度2.5倍。
H=2.5×10.73m=27.0mhm=H+h/2 见《建筑基坑支护技术规程》附录h= H0- S‘ =10.73m-4.8m=5.93m hm=(27.0+5.93)/2=16.5md、一级井点降水影响半径:R=2S√HK 一级井点基坑中心要求深度SS=2.55mR=2×2.55× 27.0×1.0=26.5me、基坑等效半径r0=0.29(a+b)=0.29(44.40+17.60)=17.98m27.02-16.52涌水量Q=1.366Klg(1+26.5/17.98)+lg(1+0.2 ×16.5/ 17.98)(16.5-1)/l=408m3/df、确定井点管数井点管数n=1.1×Q/q Q=408m3/d单根井管q=65∏dl3√K =8.6m3 Q取单根井管经验值q=5m3/dn=90根设计计算值g、间距的计算:D=L/nh、基坑长度的计算:(44.4+17.6)×2=124D=124/90= 1.38m 符合施工技术的一般规定0.8m~1.6m,见《建筑施工技术》P25,按施工技术取间距1.2m 设一根支管。
山东轻型井点降水定额明细
山东轻型井点降水定额明细1. 引言本文旨在对山东地区轻型井点降水定额进行详细的说明和解析。
通过分析该定额的内容和计算方法,我们可以更好地了解山东地区轻型井点降水的特点和规律,为工程建设提供参考依据。
2. 轻型井点降水定额的定义轻型井点降水定额是指在山东地区进行工程建设时,根据该地区历史气象数据和相关统计分析得出的一种预测值,用于确定工程项目中需要考虑的降水量。
它是根据山东地区的气候特征、地形条件等因素综合考虑而得出的。
3. 定额计算方法轻型井点降水定额的计算方法主要包括以下几个步骤:3.1 数据收集与整理首先,需要收集并整理山东地区历史气象数据,包括降雨量、降雨频率、持续时间等信息。
这些数据可以从气象部门、历史记录等渠道获取。
3.2 统计分析与模型建立在收集到足够多的历史气象数据后,可以进行统计分析,包括计算平均降雨量、频率分布等。
同时,可以建立相应的数学模型,用于预测未来的降雨情况。
3.3 定额确定根据统计分析和模型预测结果,可以得出山东地区轻型井点降水定额。
定额通常以每小时、每天、每年等形式表示,并根据工程需要进行细化和调整。
4. 定额明细说明轻型井点降水定额明细包括以下几个方面的内容:4.1 降雨量降雨量是指在一定时间内某个地点上空的降水总量。
根据历史气象数据和统计分析结果,可以得出山东地区不同时间尺度下的平均降雨量。
这些数据对于工程建设中排水系统设计、抗洪能力评估等方面具有重要意义。
4.2 降雨频率降雨频率是指某个特定强度的降雨在一定时间内发生的概率。
通过统计分析历史气象数据,可以确定山东地区不同强度、不同持续时间下的降雨频率。
这些数据对于工程建设中的抗洪设计、排水系统规划等方面具有指导作用。
4.3 持续时间降雨持续时间是指降雨事件从开始到结束所经历的时间。
通过分析历史气象数据,可以确定山东地区不同强度、不同频率下的降雨持续时间。
这些数据对于工程建设中的排水系统设计、蓄洪区规划等方面具有重要意义。
轻型井点降水
轻型井点降水摘要:轻型井点降水速度快,施工简便,安全可靠,水位方便控制,已越来越被人们广泛的应用.本文结合某厂房工程成功的工程实例作简要介绍.关键字:轻型井点,降水在基础工程施工中经常会遇到地下水的问题,特别是在市区繁华地段施工,基坑面积大,深度大时更为棘手,如果施工措施不当,就会造成不同程度的经济损失和人员伤亡,这种情况屡见不鲜。
轻型井点是沿基坑四周每隔一定距离埋入井点管(直径38--51MM,长5--7M的钢管)至蓄水层内,利用抽水设备将地下水从井点管内不停抽出,使原有地下水降至坑底以下。
在施工过程中要不断的抽水,直至施工完毕。
工程概况:某厂房设备基础施工,基坑底宽8m,长12m,基坑深4.5m,挖土边坡1:0.5,基坑平、剖面如下图所示。
经地质勘探,天然地面以下1m为亚粘土,其下有8m厚细砂层,渗透系数K=8m/d,细砂层以下为不透水的粘土层。
地下水位标高为-1.5m。
采用轻型井点法降低地下水位。
一、轻型井点的设计轻型井点降水法施工的计算步骤为:1)确定井点系统的布置方式(平面布置和高程布置)。
2)计算涌水量。
3)计算井点数量和井距。
4)抽水设备选用。
1)井点系统的布置根据本工程地质情况和平面形状,轻型井点选用环形布置。
为使总管接近地下水位,表层土挖去0.5m,则基坑上口平面尺寸为12m×16m,布置环形井点。
总管距基坑边缘1m,总管长度L=[(12+2)+(16+2)]×2=64(m)水位降低值S=4.5-1.5+0.5=3.5(m)采用一级轻型井点,井点管的埋设深度(总管平台面至井点管下口,不包括滤管)HA3H1+h+IL=4.0+0.5+×()=5.2(m)采用6m长的井点管,直径50mm,滤管长1.0m。
井点管外露地面0.2m,埋入土中5.8m (不包括滤管)大于5.2m,符合埋深要求。
井点管及滤管长6+1=7m,滤管底部距不透水层1.70m ((1+8)-(1.5+4.8+1)=1.7),基坑长宽比小于5,可按无压非完整井环形井点系统计算。
轻型井点降水法
一)轻型井点降水施工方案1.井点布置本工程基础持力层在三层土2m以下,原始地面往下不足1m,三层土含水率平均值为24.9。
施工中将考虑全线采用轻型井点法降水。
轻型井点系统由井点管、联接管(橡胶或钢管)、总管和抽水设备所组成。
其中实管6m,滤管1.5m。
地下水经井点管、联接管和总管由抽水设备抽走。
井点系统布置采用单排线状井点,井点管位于沟槽上口宽度以外1m。
在井点管延长线位置上挖一50×50cm断面的泄水沟,再在井点管位置上做好标志,井点管间距为1.5m;每40m为一井点组。
人防地下室周长592.3m,预计分为15组。
2.井点施工a. 本工程±0.000相当于八五高程10.09m,人防地下室大面积筏板开挖深度为-5.700m,局部地梁开挖至-6.300m,集水坑开始至-7.200m。
一级抽水设备无法一次性到位。
考虑整体开挖至-2.500m处,再插一级井点管。
b. 井点管的埋设可直接用井点管水冲下沉,也可用套筒式冲孔或钻孔后再将井点管沉入。
本工程采用套筒式冲孔法埋设井点管。
c. 套筒直径30cm,长度约10m,底部呈锯齿形。
上部有提梁,用起重机吊住并上下移动,套筒内有水枪,水枪直径75mm,喷嘴直径20mm,由多级水泵供给高压水,水压0.6~0.8MPa,冲孔深度比滤管底深0.5m左右;d. 井孔冲成后,拔出套筒并立即插入井点管,在保障居中并垂直情况下,向孔内填装滤料,直到距地面1m深的范围内,用粘土填实,以防漏气。
e. 井点管埋设后,即可接通总管和抽水系统,进行试抽,检查抽水效果。
3.轻型井点注意事项a. 做好准备工作:做好抽水试验,分析水文地质条件,使井位、井深、滤管长度、标高设计合理可靠。
b. 超前降水:降水领先、开槽在后。
在施工过程中始终保持干槽作业,降水速度超前于挖槽速度。
地下水位降至槽底以下0.5~0.8m之后,才能开始挖槽,并在施工过程中始终保持这水位。
c. 冲点注意操作安全:查清地下障碍物、和地面供电线路保持安全距离。
山东轻型井点降水定额明细
山东轻型井点降水定额明细摘要:一、引言二、山东轻型井点降水定额概述1.定义及作用2.适用范围三、山东轻型井点降水定额明细1.降水深度与降水井点间距的关系2.降水井点数量与降水深度的关系3.降水定额的确定因素4.降水定额的计算方法5.降水定额的应用实例四、山东轻型井点降水定额的实用性分析1.提高降水效果2.降低工程成本3.保障施工安全五、结论正文:一、引言随着我国城市化进程的加快,基础工程建设日益增多,降水工程在很大程度上影响了工程的顺利进行。
山东轻型井点降水定额明细作为一种有效的降水方法,得到了广泛的应用。
本文将对山东轻型井点降水定额进行详细阐述,以期为降水工程提供参考。
二、山东轻型井点降水定额概述1.定义及作用山东轻型井点降水定额是指在一定的工程条件下,采用轻型井点降水方法所需的降水深度、井点间距、井点数量等参数。
它具有结构简单、施工方便、降水效果明显等特点,适用于各类基础降水工程。
2.适用范围山东轻型井点降水定额适用于市政工程、公路桥梁、地铁、隧道、房屋建筑等基础降水工程。
在软土地基、含水量高的地层中,采用轻型井点降水定额可有效降低地下水位,保证工程顺利进行。
三、山东轻型井点降水定额明细1.降水深度与降水井点间距的关系降水深度与降水井点间距密切相关。
一般情况下,降水深度越大,降水井点间距越小。
这是因为降水深度增大,所需降水分散范围扩大,井点间距相应减小,以保证降水效果。
2.降水井点数量与降水深度的关系降水井点数量与降水深度成正比。
随着降水深度的增加,降水井点数量需相应增加,以保证降水效果的稳定性。
3.降水定额的确定因素降水定额的确定因素主要包括工程类型、地质条件、降水深度、井点间距等。
在实际工程中,应根据具体情况合理选择降水定额,以实现最佳降水效果。
4.降水定额的计算方法降水定额的计算方法主要包括经验公式法和数值模拟法。
经验公式法是根据大量实测数据总结出来的,适用于一般情况。
数值模拟法适用于复杂地质条件和工程场景,可更精确地计算降水定额。
轻型井点降水施工计算实例
轻型井点降水施工计算实例井点降水, 实例, 施工一、总涌水量计算1.基坑总涌水量Q(m3/d),即环形井点系统用水量,常按无压完整井井群,用下式计算公式:(2H―s)sQ=1.366KlgR―lgx02.单井井点涌水量q(m3/d)常按无压完整井,按下计算公式:(2H―s)sq=1.366KlgR―lgr式中:K—土的渗透系数(m/d);H—含水层厚度(m);s—水的降低值(m);R—抽水影响半径(m),由现场抽水试验确定,也可用下式计算:R=1.95 s√H• Kr—井点的半径(m);x0—基坑的假想半径(m,当矩形基坑长宽比小于5时,可化成假想半径x0的圆形井,按下式计算:x0=√F/πF—基坑井点管所包围的平面面积(m2);π—圆周率,取3.1416;二、井点管需要根数井点管需要根数n可按下式计算:Qn=mq式中 q=65π•d•l 3√K式中:n—井点管根数;m—考虑堵塞等因素的井点备用系数,一般取m=1.1;q—单根井点管的出水量(m3/d);d—滤管直径(m);l—滤管长度(m);三、井点管平均间距井点管平均间距D(m),可按下式计算:2(L+B)D=n-1求出的D应大于15d,并应符合总管接头的间距(一般为80、120、160mm)要求。
式中:L—矩形井点系统的长度(m);B—矩形井点系统的宽度(m);四、例题某工程基坑平面尺寸见图,基坑宽10m,长19m,深4.1m,挖土边坡1:0.5。
地下水位-0.6m。
根据地质勘察资料,该处地面下0.7m,为杂填土,此层下面有6.6m的细砂层,土的渗透系数K=5m/d,再往下为不透水的粘土层。
现采用轻型井点设备进行人工降低地下水位,机械开挖土方,试对该轻型井点系统进行计算。
解:(1)井点系统布置该基坑顶部平面尺寸为14m×23m,布置环状井点,井点管离边坡为0.8m。
要求降水深度s =4.10-0.6+0.5=4.0m,因此,用一级轻型井点系统即可满足要求,总管和井点布置在同一水平面上。
山东轻型井点降水定额明细
山东轻型井点降水定额明细【最新版】目录1.概述2.山东轻型井点降水定额明细的具体内容3.山东轻型井点降水定额明细的应用4.总结正文1.概述山东轻型井点降水定额明细是一份详细列举了山东地区轻型井点降水工程量、工程费用以及材料消耗等方面的明细表。
这份明细表对于从事井点降水工程的设计、施工及预算人员具有重要的参考价值,能够帮助他们更加准确地了解工程所需的各项资源和费用。
2.山东轻型井点降水定额明细的具体内容山东轻型井点降水定额明细主要包括以下几个方面的内容:(1) 工程量:明细表中列举了不同类型的轻型井点降水工程所需的工程量,如钻井数量、井深、井径等。
(2) 工程费用:明细表中根据不同类型的工程量给出了相应的工程费用,包括人工费、材料费、机械使用费等。
(3) 材料消耗:明细表中详细列举了各种材料在轻型井点降水工程中的消耗量,如管材、井壁材料、滤料等。
(4) 工程周期:明细表中还给出了不同类型的轻型井点降水工程的预计工程周期,有助于施工方合理安排工程进度。
3.山东轻型井点降水定额明细的应用山东轻型井点降水定额明细在实际应用中具有以下作用:(1) 指导工程设计:设计人员可以根据明细表中的工程量和费用等信息,进行工程方案的设计和优化。
(2) 控制工程预算:建设单位和施工方可以根据明细表中的费用数据,制定和控制工程预算。
(3) 指导工程施工:施工方可以根据明细表中的工程量、材料消耗和工程周期等信息,进行施工计划的制定和施工过程的控制。
(4) 总结山东轻型井点降水定额明细为山东地区的井点降水工程提供了详细的工程量、费用和材料消耗等方面的数据,对于指导工程设计、控制工程预算和指导工程施工具有重要的参考价值。
轻型井点降水专项方案
一、工程概况本工程位于XXX地区,工程性质为住宅小区建设。
由于地质条件复杂,地下水位较高,为保证基坑开挖及基础施工顺利进行,特制定本轻型井点降水专项方案。
二、编制依据1. 国家现行施工验收规范、标准及地方有关施工规定。
2. 《岩土工程勘察报告》。
3. 《建筑工程施工质量验收统一标准》。
三、施工方案1. 降水目标将基坑周边地下水位降至坑底以下,确保基坑开挖及基础施工顺利进行。
2. 降水方法采用轻型井点降水法,沿基坑四周每隔一定间距布设井点管,井点管底部设置滤水管插入透水层,上部接软管与集水总管进行连接。
3. 井点布置(1)井点管直径:采用直径48mm的无缝钢管或镀锌管,壁厚为3.0mm。
(2)井点管长度:约2.0m。
(3)井点间距:根据地质条件及地下水位情况,井点间距宜为1.5m~3.0m。
(4)井点布置形式:单排线状井点布置在地下水流的上游一侧,两端延伸长度一般不小于沟槽宽度。
4. 井点施工(1)井点管埋设:采用套筒式冲孔法埋设井点管。
(2)套筒直径:30cm,长度约10m,底部呈锯齿形。
(3)套筒内水枪直径:75mm,喷嘴直径20mm。
(4)水压:0.6MPa。
(5)井点管连接:井点管、联接管(橡胶或钢管)、总管连接牢固,确保抽水效果。
5. 抽水设备(1)采用真空吸水泵进行抽水。
(2)水泵型号:根据井点数量及抽水量选择合适型号。
(3)水泵安装:水泵应安装在集水总管附近,确保水泵运行正常。
6. 降水效果监测(1)每日监测井点水位,确保地下水位降至坑底以下。
(2)定期检查井点管、联接管、总管及抽水设备,确保降水系统正常运行。
四、施工注意事项1. 井点管埋设过程中,注意保护地下管线及构筑物。
2. 井点施工期间,加强对施工区域的巡查,确保施工安全。
3. 降水过程中,密切关注周边环境变化,确保周边建筑物及设施安全。
4. 降水结束后,及时回填井点管,恢复原状。
五、总结本轻型井点降水专项方案旨在确保基坑开挖及基础施工顺利进行。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
轻型井点降水法工程量的计算及如何套定额
轻型井点降水法施工的计算步骤是什么?降水法施工的适用条件与范围是什么?
一、轻型井点降水法施工的计算步骤为:确定井点系统的布置方式(平面布置和高程布置);计算涌水量;计算井点数量和井距;校核水位降低数值;选择水泵规格等。
二、井点降水是高地下水位地区基础工程施工的重要措施之一。
它能克服流砂、稳定基坑边坡、降低承压水位防止坑底隆起和加速土的固结,使位于天然地下水位以下的基础工程能在较干燥的施工环境中进行施工。
基本上在任何场地都可以抽水,除一些保水性很好的土壤。
降水方法和设备可根据土层的渗透系数、要求降水的深度和工程特点,经过技术经济和节能比较后确定。
井点降水施工的条件是什麽,井点降水结算需结算哪些内容,这些内容怎样计算工程量,排水泵计算台班吗
井点降水施工的条件是什麽,井点降水结算需结算哪些内容,这些内容怎样计算工程量,排水泵计算台班吗
、地下水位高于基底标高
、井点安拆。
运输,使用天数
、使用天数内不计算,非使用天数内可计停班
一、井点降水施工的条件是什麽?
回答::当需开挖的基坑设计基坑底标高位于地下位以下时。
:定额要求“井点降水中的轻型井点、喷射井点、大口径井点的采用由施工组织设计确定。
一般情况下,降水深度以内采用轻型井点,以上以内采用相应的喷射井点,特殊情况下可选用大口径井点。
井点使用时间按施工组织设计确定。
喷射井点子目包括两根观察孔制作,喷射井管包括了内管和外管。
井点材料使用摊销量中已包括井点拆除时的材料损耗量”。
二、井点降水结算需结算哪些内容?
回答:主要内容有井点安装、拆除、使用等项目。
另外可能每个地区的定额子目设置不同,主要还是按当地定额设置的子目。
使用公路工程预算定额()套用定额,定额中的费用已经包括(挖排水沟及管槽,井管装配及地面试管,铺总管,装水泵,水箱,冲孔沉管理,灌砂封口,连接试帛,拔井管,拆管,清洗,整理,堆放),
三、这些内容怎样计算工程量,排水泵计算台班吗?
回答:轻型井点根为一套。
井点工程量按"套天"为单位计算,累计根数不足一套者按一套计算,一天按小时计算。
井管的安装、拆除工程量按根计算。