XR06CX(小精灵说明书)
路由器-WayOS 路由产品-用户手册说明书
WayOS路由产品用户手册尊敬的客户您好!承蒙惠顾WayOS产品,谨致谢意!目录一、路由向导 (6)二、系统状态 (8)2.1网络状态 (8)2.2流量分析 (9)2.2.1广域网 (9)2.2.2应用协议 (12)2.3主机监控 (13)2.3.1主机监控 (13)2.3.3PPPoE用户 (14)2.3.4DHCP用户 (15)2.3.5聊天账号 (15)2.4登陆记录 (15)2.5操作记录 (16)2.5系统日志 (16)三、网络配置 (17)3.1局域网 (18)3.2广域网 (20)3.3动态域名 (26)3.4接口设置 (27)3.5一线多拨 (28)四、智能流控 (29)4.1优先级设置 (29)4.2宽带限制 (32)4.3宽带保证 (35)4.4控制例外 (36)五、AC管理 (37)AC平台服务端 (37)六、VPN应用 (38)6.1PPTP配置 (38)6.1.1PPTP服务 (38)6.1.2PPTP用户 (39)6.1.3PPTP客户端 (40)6.2IPSec配置 (42)6.2.1IPSec网对网 (42)6.2.2IPSec点对网 (44)6.2.3L2TP IPSec (45)6.3OVPN配置 (46)6.3.1OVPN设置 (46)6.3.2OVPN证书 (50)6.3.3OVPN日志 (51)七、进程管理 (52)7.1进程管理 (52)7.1.1进程列表 (52)7.1.2组列表 (52)7.2基本设置 (53)7.2.2提示管理 (54)7.3进程管理 (54)八、行为管理 (59)8.1行为识别 (59)8.2聊天软件 (61)8.2.1QQ黑白名单 (61)8.2.2淘宝旺旺黑白名单 (62)8.2.3移动QQ黑白名单 (63)8.3高级设置 (63)8.3.1WEB关键字过滤 (63)8.3.2禁止WEB提交 (64)8.3.3后缀名过滤 (65)8.4邮件监控 (67)8.4.1邮箱白名单 (67)8.4.2WEB邮箱过滤 (68)8.4.3WEB邮箱白名单 (69)8.5网址管理 (69)8.5.1网址防火墙 (69)8.5.2网址数据库 (70)8.5.3网址分类组 (71)8.5.4日志 (72)8.6域名管理 (72)8.6.1域名解析 (72)8.6.2域名过滤 (72)8.6.3域名重定向 (73)8.7URL重定向 (74)8.7.1URL重定向 (74)8.7.2日志 (74)8.8行为管理日志 (75)九、认证管理 (75)9.1云计费 (75)9.2智慧WiFi (76)9.3基本设置 (78)9.4页面管理 (80)9.5PPPOE设置 (81)9.6PPPOE扩展设置 (83)9.6用户管理 (84)9.7Radius设置 (86)十、防御配置 (87)10.1ARP管理 (87)10.1.1ARP列表 (87)10.1.2ARP防御 (89)10.1.3ARP日志 (89)10.2访问控制 (90)10.2.1访问控制 (90)10.3MAC过滤 (93)10.4连接限制 (94)10.5DDOS防御 (95)10.6Ping WAN口 (96)10.7连接数设置 (97)十一、USB存储 (97)11.1设备状态 (97)11.2共享服务 (97)11.3USB日志 (99)11.44G上网 (99)11.4.14G上网设置 (100)11.4.2接口状态 (100)11.5网络打印机 (101)十二、高级设置 (102)12.1策略路由 (102)12.1.1策略路由 (102)12.1.2负载均衡 (103)12.1.3地址范围 (105)12.1.4线路状态 (106)12.1.5日志 (106)12.2通告系统 (107)12.2.1规则管理 (107)12.2.2文件编辑 (109)12.2.3日志 (109)12.3端口映射 (110)12.3.1端口映射 (110)12.3.2DMZ设置 (113)12.3.3UPNP设置 (113)12.4NAT转换 (114)12.4.1NAT一对一规则 (114)12.4.2NAT多对多规则 (115)12.5NAT快速转发 (116)12.6端口设置 (117)12.7路由表 (117)12.7.1当前路由表 (117)12.7.2静态路由表 (118)12.8WEB访问设置 (119)12.9端口镜像 (120)12.10端口VLAN (121)十三、系统维护 (121)13.1Ping检测 (121)13.2网络唤醒 (122)13.3系统控制 (123)13.4系统更新 (123)13.5远程维护 (124)13.5.1远程控制 (125)十四、快捷菜单 (126)(图8)路由器默认的用户名是“root”密码为“admin”,您可以在‘高级配置-访问设置’里自定义更改登陆的用户名及密码。
WFT06X 中文说明书
CH6
CH1
在(B)、(E)、(F)向下、(D)向上时: 副翼使用2个舵机, 调6通道旋扭, 左右两边副翼有同 时上下动作功能。左右打1通道杆时左右两边副翼同时 差动 ; 左侧副翼与CH6连接, 右侧副翼与CH1连接。
固定翼V尾翼混控功能(V-TAIL)
CH2 CH4 (CH4) (CH2)
(1) 固定翼1、2、4、6小动±100%与大动±125%舵角切换。 (2) 固定翼1、6通道混控 ; 副襟翼混控功能(FLAPERON)。 (3) 固定翼4、2通道混控 ; V尾混控功能(V-TAIL)。 (4) 固定翼1、2通道混控 ; 三角翼混控功能(ELEVON)。 (5) 直升机3通道对4、6通道混控。 (6) 直升机3通道只对6通道混控。 (7) 1、2、3、4、6通道反向开关。 (8) 普通模式可用于车模和船模。 (9) 低电压声光提示: 当电池电压低于8.8V时电源指示灯1S/1S闪烁同时发出蜂
向上打为4、2通道混控关系(V尾翼混控V-TAIL)。 在固定翼状态且(D)向上打时 : 向上打为1、2通道混控(三角翼混控功能 ELEVON) 。
此时(E)的功能无效。 1通道为副翼反向开关, 向下打为正常模式, 向上打反向动作。 2通道为升降舵反向开关, 向下打为正常模式, 向上打反向动作。 3通道为油门反向开关, 向下打为正常模式, 向上打反向动作。 4通道为方向舵反向开关, 向下打为正常模式, 向上打反向动作。 6通道为(襟翼/螺距)反向开关, 向下打为正常模式, 向上打反向动作。
鸣声 ; 电池电压低于8.3V时电源指示灯0.5S/1S闪烁同时发出蜂鸣声。
1 2 3 46 REV
NOR
(A)(B)(C)(D)(E)(F)(G)(H) (I) (J) (K)
XR10CX-dixell小精灵说明书
: To display target set point; in programming mode it selects a parameter or confirm an operation. (DEF) Not enabled (UP): To see the max. stored temperature; in programming mode it browses the parameter codes or increases the displayed value. (DOWN) To see the min stored temperature; in programming mode it browses the parameter codes or decreases the displayed value. To switch the instrument off, if onF = oFF. Not enabled KEY COMBINATIONS:
Temper. SET Time Compr. ON
Digital controller with cooling or heating action
XR10CX
CONTENTS 1. GENERAL WARNING ___________________________________________________ 1 2. GENERAL DESCRIPTION _______________________________________________ 1 3. CONTROLLING LOADS _________________________________________________ 1 4. FRONT PANEL COMMANDS _____________________________________________ 1 5. MAX & MIN TEMPERATURE MEMORIZATION _______________________________ 1 6. MAIN FUNCTIONS _____________________________________________________ 2 7. PARAMETERS ________________________________________________________ 2 8. DIGITAL INPUT (ENABLED WITH P3P = N) _________________________________ 3 9. TTL SERIAL LINE – FOR MONITORING SYSTEMS ___________________________ 3 10. X-REP OUTPUT – OPTIONAL ____________________________________________ 3 11. INSTALLATION AND MOUNTING _________________________________________ 3 12. ELECTRICAL CONNECTIONS ____________________________________________ 3 13. HOW TO USE THE HOT KEY _____________________________________________ 3 14. ALARM SIGNALS ______________________________________________________ 3 15. TECHNICAL DATA _____________________________________________________ 3 16. CONNECTIONS _______________________________________________________ 4 17. DEFAULT SETTING VALUES _____________________________________________ 4
帝斯勒 dIXEL XR30CX 微型电子温控器 安装使用手册说明书
帝思微型电子温控器(停机融霜、多功能继电器输出)XR30CX请在使用前详细阅读本说明书请将说明书放在温控器附近,以便在需要时能够尽快查阅。
通电前请检查电源电压是否正确。
为适用于中温停机融霜制冷系统的微型温度控制器,压缩机(制冷输出,也可以控制供液电磁阀)压缩机输出的状态依据探头测得面板的键盘操作(设定键):在非编程状态下,按一次可显示目标设定点,在编程状态下可用来选择某一参数或确认一个操作。
6.2如何修改设定值1.持续按下SET 键 2秒钟;2.设定值将被显示出来,并且 “°C” 或 “°F” LED图标指示灯开始闪烁;3.在10秒钟内,通过按或键来修改设定值。
4.要存储新的设定值可再按一次SET 键或者等待10秒钟。
6.3如何启动一次手动融霜持续按下键超过 2秒钟,就可以启动一次手动融霜。
6.4如何修改参数值(进入用户层,第一层)修改参数值的操作如下:1.持续按下SET+ 键超过3秒钟进入编程状态 (“°C” 或“°F”LED图标闪烁)。
2.按或键选择需要的参数,再按 “SET”键来显示参数值。
3.用或键来修改参数值。
4.再按 “SET”键来确认并存储新值,紧接着会显示下一个参数名称。
退出:按下并立即放开SET+ 组和键或不按任何键等待15秒。
注意:不按任何键等待15秒退出时,新值也会被存储。
6.5隐藏参数(第二层)进入隐藏参数层可以浏览到温控器的所有参数。
6.5.1 如何进入隐藏参数层1.首先持续按下SET+ 组合键超过3秒进入(第一层)编程状态 (“℃” 或“°F”LED图标灯闪烁)。
2.释放上述组合键,然后再持续按下SET+ 键超过7秒钟,Pr2字符会一闪而过,紧接着Hy参数会显示出来。
此时您已经进入隐藏参数层。
3.按或键选择需要的参数。
4.按 “SET” 键显示其参数值。
5.用或键来改变其值。
6.再按 “SET”键存储新值,紧接着会显示下一个参数名称。
XR03CX-XR04CX小精灵dixell出口英文说明书
XR03CX – XR04CX
1 CONTENTS
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Contents ____________________________________________________________________________ 1 General warnings _____________________________________________________________________ 1 General description ___________________________________________________________________ 1 Regulation __________________________________________________________________________ 1 Defrost _____________________________________________________________________________ 1 Front panel commands ________________________________________________________________ 1 Parameters __________________________________________________________________________ 2 Digital inputs _________________________________________________________________________ 2 Installation and mounting _______________________________________________________________ 2 Electrical connections _________________________________________________________________ 2 How to use the hot key_________________________________________________________________ 2 Alarm signalling ______________________________________________________________________ 2 Technical data _______________________________________________________________________ 3 Connections _________________________________________________________________________ 3 Default setting values __________________________________________________________________ 3
意大利小精灵电子温控器RC说明书
进入隐藏参数层可以浏览到温控器的所有参数。
如何进入隐藏参数层 1. 首先持续按下 SET+ 组合键超过 3 秒进入(第一层)编程状态 (“°C” 或“°F” LED 图
标灯闪烁)。 2. 释放上述组合键,然后再持续按下 SET+ 键超过 7 秒钟, L2 字符会一闪而过,紧
接着 Hy 参数会显示出来。 此时您已经进入隐藏参数层。 3. 选择需要的参数。 4. 按 “SET” 键显示其参数值。 5. 用 或 键来改变其值。 6. 再按 “SET”键存储新值,紧接着会显示下一个参数名称。 退出:按下并立即放开 SET+ 组和键或不按任何键等待 15 秒。 注 1:如果在用户层(第一层)没有一个参数,在进入第一层 3 秒钟后会显示“nP” 字 符信息,持续按下上述组合键直到 L2 字符出现后进入第二层参数。 注 2:不按任何键等待 15 秒退出时,新值也会被存储。
数,在此时间内任何输出都维持在未通电时的状态。 AC 防频繁启动延时: (0~50 分钟):从压缩机停机到紧接着的开机需要延时的时
间,以保护压缩机不出现频繁启动。 Cy 探头失灵时压缩机开机时间: (0~99 分钟):当温度探头失灵时压缩机开机运转
时间, 当 Cy=0 、Cn≠0 时压缩机总是停机。 Cn 探头失灵时压缩机停机时间: (0~99 分钟) :当温度探头失灵时压缩机停机时
用,应避免在高湿度环境下温度的剧烈变化而使得水蒸气凝结在内部的电路板上。 • 注意:在检修前请断开温控器电源,最好断开所有连接线路,以防止意外发生。 • 探头要固定在使用者不易碰到的地方,非专业人员请勿擅自打开温控器外壳。 • 一旦发现有故障或不能正常控制时,请将温控器和详细的故障描述一起发送到帝
思·小精灵的代理商或帝思中国代表处(北京),联系方式见本说明书结尾处。 • 应用时请注意每一个输出继电器触点的最大允许瞬时电流和额定电流( 参见技术数据) • 请确保探头的连接电缆与电源、负载输出电缆分开,并保持适当间距,不要交叉或缠
索爱使用手册
應用程式及內容............................................................................38 PlayNow™........................................................................................38 Android™ Market..............................................................................40 管理應用程式....................................................................................40 受版權保護的內容............................................................................41
小精灵XR03CX中文说明书
使用手册
编号 1592020130
小精灵微型电子温控器
XR03CX – XR04CX
1. 目录
1. 目录_______________________________________________________________________________ 1 2. 注意事项 __________________________________________________________________________ 1 3. 概述_______________________________________________________________________________ 1 4. 控制调节原理______________________________________________________________________ 1 5. 融霜_______________________________________________________________________________ 1 6. 面板的键盘操作 ___________________________________________________________________ 1 7. 参数_______________________________________________________________________________ 2 8. 数字开关量输入(仅适用于 XR03CX) __________________________________________________ 2 9. 安装与固定 ________________________________________________________________________ 2 10. 电气连接 __________________________________________________________________________ 2 11. 如何使用编程钥匙 _________________________________________________________________ 2 12. 报警信号 __________________________________________________________________________ 2 13. 技术参数 __________________________________________________________________________ 3 14. 接线图 ____________________________________________________________________________ 3 15. 参数表及出厂设定值 _______________________________________________________________ 3
MINIX用户使用手册
MINIX“极趣”用户使用手册V1.0修订日期2014.10.25说明免责声明任何用户在使用本产品前之前,请仔细阅读本声明,一旦使用本产品,即视为对本声明全部内容的认可和接受。
1.请在当地法律法规允许的范围内使用本产品,极飞不承担因任何非法使用导致的法律责任。
2.本产品属于遥控航模,请严格遵守航模产品的安全操作规范,极飞不承担因任何操作和使用控制上导致的任何性能、安全与法律责任。
3.航模不是玩具,请在专业人员指导下飞行,并按本说明书安装和使用本产品,极飞不对因用户安装、配置、操作等导致的航模事故负责。
安全注意事项出于安全考虑,飞行前请关注以下注意事项:1.熟悉飞行环境,飞行时远离障碍物、人群、高压线、树木遮挡、水面等。
2.切勿疲劳、酒后或精神不佳时飞行,以免发生意外。
3.远离潮湿环境,切勿大风天气或雨天飞行,否则将造成电子设备故障发生危险。
4.远离热源,以免造成电子设备或其它部件损坏。
5.初学阶段不要独自飞行。
建议飞行之前先向有经验的飞行员获取帮助。
6.准备救援工具,如手机、对讲机。
7.务必在安全重量下起飞,以免发生危险。
8.飞行前必须检查设备是否正常,是否存在同频干扰。
9.远离运转中的机器,切勿用身体接触旋转中的电机或螺旋桨,更不要用手抓。
飞行时切勿穿宽松衣服以免与遥控器或螺旋桨发生牵扯造成意外。
10.飞行器起飞前请将遥控器油门杆保持在最低点。
11.建议在无桨状态下调试飞行器,检查遥控设备和电机工作是否正常,一切正常之后再安装螺旋桨,以免造成安全事故。
知识产权声明本手册内容(包括文字与图片)版权为极飞公司所有。
任何个人或法人实体,未经极飞公司的书面许可,不得以任何形式对其内容进行翻译、修改或改编,违者将追究其法律责任。
极飞公司保留对本手册内容以及产品技术规格进行修改的权利,以便向用户提供最新、最先进的产品。
用户可从极飞公司的官网上下载最新的产品更新资料。
目录说明 (2)免责声明 (2)安全注意事项 (2)知识产权声明 (2)产品简介 (3)飞控系统组成模块 (3)功能特性 (4)技术参数 (4)模块参数 (5)接口定义 (6)主控器模块的端口 (6)飞行控制模式 (7)LED指示灯状态描述 (8)快速使用指南 (8)使用注意事项 (9)安装连接篇 (10)接收机安装 (11)外接接收机 (11)供电 (11)校准篇 (12)电子罗盘校准 (12)遥控器中立点校准 (13)遥控器反舵校准 (13)基础飞行篇 (15)飞行前注意事项 (15)启动/停止电机 (15)自动起飞 (16)辅助定高 (16)姿态感度 (16)智能低电压保护 (18)安全模式 (18)高级功能篇 (20)失控保护功能 (20)MINIX OSD模块 (21)固件&调参软件升级 (23)固件升级 (23)调参软件升级 (23)飞控信息及语言切换 (24)XAIRCRAFT MINIX售后服务 (24)产品简介“极趣“MiniX是针对多旋翼模型爱好者专门设计的一款智能飞行控制系统,它不仅很好的延续了极飞飞控的稳定性和安全机制,而且通过高度集成的设计原理,大幅度减小了飞控系统的体积,降低了飞控安装和调试的复杂度,飞行可靠,简单易用,无需安装调参软件,仅需少量设置和调试即可飞行,更好地满足了大众模型玩家对飞行的需求。
温控小精灵60C中温说明书
3.3 蒸发器风扇控制
通过“FnC”参数选择风扇控制模式: FnC = C_n 风扇与压缩机同起同停,融霜期停止工作; FnC = o_n 压缩机停止,风扇工作,融霜期停止工作;由“Fnd”
参数设置融霜后,蒸发器排水时间。
FnC = C_Y FnC = o_Y
风扇与压缩机同起同停,融霜期工作; 融霜期风扇继续工作。
Ot 温控器探头校准值:(-12.0~+12.0℃)能够调节温控器探头温差 补偿。 P2P 当前蒸发器探头: n= 当前无: 融霜按时间停止 y= 当前有,融霜 按温度停止。 • OE 蒸发器探头校准值: (-12.0~12.0°C).能够调节蒸发器探头温差 补偿 。 • OdS 启动时输出延时: (0~255 分)该功能在设备首次启动及参 数设定时禁止任何输出时有效。 AC 抗短路延时:(0~50 分)压缩机停止及重新启动的时间间隔。 • CCt 持续周期压缩机运行时间: (0.0~24.0 小时;设定值~10 分)能 够设置持续周期时间:“CCT”时间参数未打断前,压缩机持续 工作。如库中放满新产品时也能使用 。 • COn 探头失灵时压缩机运行时间:(0~255 分) 探头失灵后,压 缩机工作时间。COn=0 时压缩机处于关机状态。 • COF 探头失灵时压缩机停止时间: (0~255 分) 探头失灵后压缩机 停止工作时间。COF=0 时压缩机运行。
Dixell
使用手册
XR60C 冷冻型电脑控制器 使用说明
1. 注意事项 ________________________________1 2. 概述 _____________________________________1 3. 控制负载 ________________________________1 4. 键盘 _____________________________________1 5. 温度报警及记录周期(HACCP) __________1 6. 主要功能 ________________________________2 7. 参数 _____________________________________2 8. 数字输入_________________________________3 9. 安装固定方法 ____________________________3 10.电气连接 __________________________________3 11. 编程钥匙使用 ____________________________4 12. 报警信号 ________________________________4 13. 技术参数 ________________________________4 14. 电气连接 ________________________________4 15. 缺省设定值 ______________________________4
小精灵门禁快速操作指引V6[1].0
主菜单|—时钟管理| |—设置时间 | |—误差校准| | |—无需调整 | | |—每天调快 | | |—每天调慢 | |—报闹时间| | |—闹铃01->| | | |—开启闹铃 | | | |—报闹时间 | | | |—持续时间| | | |—闹铃星期—星期日、星期一…星期六 | | | 。
| | |—闹铃16(同上) |—卡片管理| |—增加卡片 | |—修改卡片 | |—删除卡片 |—系统设置| |—设备机号| |—背光模式—关闭、常开、自动、时区 | |—发音提示—键盘音、闹铃音、提示音| |—通讯速率—2400bps 、4800bps 、9600bps 、19200bps| |—记录选项—进门记录、出门记录、事件记录、记满循环、禁止相同、容量预警 | |—菜单密码 | |—资源统计 | |—清除系统 | |—软件升级 |—门禁管理| |—设置门1| | |—权限设置| | | |—时段表—(时段0——时段31) | | | |—时区表—(时区0——时区63) | | | |—节假日| | | |—应用群组—(应用群组0——应用群组15)| | |—管制类型—进出双管、进入单管、进管出任、潜回互锁 | | |—进入方式—只需刷卡、只需密码、卡加密码 | | | |—开启群组、关闭群组 | | |—门磁类型—门磁常开、门磁常闭、火警常开、火警常闭、无效 | | |—开门按钮—常开、常闭、无效 | | |—开门时间 * | | |—关门时间| | |—首入常开—开启首开、关闭首开 | | |—胁迫密码(无报警继电器输出) | | |—开门密码| | |—密码群组—开启群组、关闭群组| | |—*输入群组— *开启群组、*关闭群组 * | |—设置门2(同上面 设置门1) | |—复制1->2门 | |—复制2->1门 |—端口设置| |—继电器1—门锁1、门锁2、电铃、报警、非法卡、无效 | |—继电器2—门锁1、门锁2、电铃、报警、非法卡、无效| |—WG 接口1—进门1、出门1、进门2、出门2、W26输出、W34输出、W44输出、无效 | |—WG 接口2—进门1、出门1、进门2、出门2、W26输出、W34输出、W44输出、无效 | |—本机读卡—进门1、出门1、进门2、出门2、无效 |—菜单语言—简体中文、English系统使用索引功能简介: 集考勤机、密码门禁、单门门禁、汉显读头和两门门禁控制器于一体。
爱默生 XR01CX 电子温度控制器产品说明书
quick reference.• The instrument shall not be used for purposes different from those described hereunder. It cannot be used as a safety device.• Check the application limits before proceeding.• Emerson Srl reserves the right to change the composition of its products, even without notice, ensuring the same and unchanged functionality.1.2 SAFETY PRECAUTIONS• Check the supply voltage is correct before connecting the instrument.•Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden temperature changes with high atmospheric humidity to prevent formation of condensation.• Warning: disconnect all electrical connections before any kind of maintenance.• Fit the probe where it is not accessible by the End User. The instrument must not be opened.• In case of failure or faulty operation send the instrument back to the distributor or to “Dixell S.r.l.” (see address) with a detailed description of the fault.• Consider the maximum current which can be applied to each relay (see Technical Data).• Ensure that the wires for probes, loads and the power supply are separated and far enough from each other, without crossing or intertwining.• In case of applications in industrial environments, the use of mains filters (our mod. FT1) in parallel with inductive loads could be useful.5. GENERAL DESCRIPTIONThe XR06CX, format 32x74x60 mm , is microprocessor based controller, suitable for applications on medium or low temperature ventilated refrigerating units. It has three relay outputs to control compressor, fan, and defrost, which can be either electrical or reverse cycle (hot gas). It is also provided with 2 NTC probe inputs, the first one for temperature control, the second one, to be located onto the evaporator, to control the defrost termination temperature and to managed the fan and it's provided with a configurable digital input. With the HOTKEY it's possible to program the instrument in a quick and easy way.6.2 COOLING APPLICATIONSThe regulation is performed according to the temperature measured by probe. The instrument is provided with the CH programmable parameter wich enables the user to set the regulation both for heating or cooling applications:• CH=cL ‑‑> cooling applications;• CH=Ht ‑‑> heating applications.The regulation is performed according to the temperature measured by the thermostat probe with a positive differential from the set point: if the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again.6.3 HEATING APPLICATIONS (Only XR01CX)The Hy value is automatically subtracted to the SET POINT. If the temperature decreases and reaches set point minus differential the output is started and then turned off when the temperature reaches set point value again.XR02CX ‑ XR03CX : Defrost is performed through a simple stop of the compressor. Parameter i d controls the interval between defrost cycles, while its length is controlled by parameter Md .XR04CX ‑ XR06CX : Two defrost modes are available through the td parameter:• td=EL defrost through electrical heater (compressor OFF);• td=in hot gas defrost (compressor ON). Other parameters are used to control the interval between defrost cycles (id ), its maximum length (Md ) and two defrost modes: timed or controlled by the evaporator's probe. A t the end of defrost dripping time is started, its length is set in the dt parameter. With dt=0 the dripping time is disabled.The free voltage digital input is programmable in different configurations by the iF parameter.11.1 DOOR SWITCH (iF=do)11.2 EXTERNAL ALARM (iF=EA)As soon as the digital input is activated the unit will wait for di time delay before signalling the EA alarm message. The outputs status don't change. The alarm stops just after the digital input is de‑activated.11.3 SERIOUS ALARM (iF=bA)When the digital input is activated, the unit will wait for di delay before signalling the CA alarm message. The relay outputs are switched OFF. The alarm will stop as soon as the digital input is de‑activated.11.5 START DEFROST (iF=dF)It starts a defrost if there are the right conditions. After the defrost is finished, the normal regulation will restart only if the digital input is disabled otherwise the instrument will wait until the Md safety time is expired.11.6 INVERSION OF THE KIND OF ACTION: HEATING ‑ COOLING (iF=Hc)This function allows to invert the regulation of the controller: from cooling to heating and viceversa.The instruments are provided with screw terminal block to connect cables with a cross section up to 2,5 mm. Before connecting cables make sure the power supply complies with the instrument's requirements. Separate the probe cables from the power supply cables, from the outputs and the power connections. Do not exceed the maximum current allowed on each relay, in case of heavier loads use a suitable external relay.13.1 PROBES The probes shall be mounted with the bulb upwards to prevent damages due to casual liquid infiltration. It is recommended to place the thermostat probe away from air streams to correctly measure the average room temperature. Place the defrost termination probe among the evaporator fins in the coldest place, where most ice is formed, far from heaters or from the warmest place during defrost, to prevent premature defrost termination.With FC parameter it can be selected the fans functioning:• FC=cn will switch ON and OFF with the compressor and not run during defrost• FC=on fans will run even if the compressor is off, and not run during defrostAfter defrost, there is a timed fan delay allowing for drip time, set by means of the Fd parameter.• FC=cy fans will switch ON and OFF with the compressor and run during defrost • FC=oY fans will run continuously also during defrost.An additional parameter FS provides the setting of temperature, detected by the evaporator probe, above which the fans are always OFF. This is used to make sure circulation of air only if his temperature is lower than set in FS .Instruments shall be mounted on vertical panel, in a 29x71 mm hole, and fixed using the special bracket supplied.The temperature range allowed for correct operation is 0÷60°C. Avoid places subject to strong vibrations, corrosive gases, excessive dirt or humidity. The same recommendations apply to probes. Let air circulate by the cooling holes.10.1 HOW TO SEE THE SET POINT1. Push and immediately release the SET key, the set point will be showed;2. Push and immediately release the SET key or wait about 5s to return to normal visualisation.10.2 HOW TO CHANGE THE SETPOINT1. Push the SET key for more than 2 seconds to change the Set point value;2. The value of the set point will be displayed and starts blinking;3. To change the SET value push the o or n arrows within 10s;4. To memorise the new set point value push the SET key again or wait 15s.10.3 HOW TO START A MANUAL DEFROST10.4 HOW TO CHANGE A PARAMETER VALUE To change the parameter's value operate as follows: 1. Enter the Programming mode by pressing the SET + keys for 3s;2. Select the required parameter. 3. Press the SET key to display its value (set value starts to blink);4. Use or to change its value;5. Press SET to store the new value and move to the following parameter.To exit : Press SET + or wait 15s without pressing a key.NOTE : the set value is stored even when the procedure is exited by waiting the time‑out to expire. Please restart the controller after change the parameters10.5 HOW TO RESET TO THE FACTORY PARAMETER VALUE(Option)In the first 60s after controller power‑on, it allows user to reset to the factory parameter through key combination with steps below:1. Start pressing DEF key and for 5s;2. Then release just but keep DEF key another 5s. Then parameter reset successfully by controller re‑start automatically.NOTE:• The Parameters Factory Reset function shall be accessible in the first 60 seconds from the device power‑on. The default configuration will initiate the loading, during this time all regulation will be interrupted, relays will be powered off, and the controllers is reset.•It allows user to reset to a customized parameter map through Hotkey, to download the parameters into the controller firstly, then execute the above 2 steps. Here is the setps to update to customized paraleter into the controller.1.Save your own parameter map into a Hotkey2.Plug‑in the hotkey into the controller, power off the controller3.Then power on the controller, the parameter into Hotkey will be downloaded into the controller automatically with display showing 'En' label.NOTE: After reset to user parameter, it will be impossible to reset to Emerson parameter anymore.10.7 TO LOCK THE KEYBOARD Keep pressed for more than 3s the keys.The PF message will be displayed and the keyboard will be locked. If a key is pressed more than 3s the PF message will be displayed.10.8 TO UNLOCK THE KEYBOARDKeep pressed together for more than 3s the keys till the Pn message will be displayed.Push the DEF key for more than 2 seconds and a manual defrost will start, the pre‑condition is evaporator probe temp lower than dE .14.2 HOW TO PROGRAM AN INSTRUMENT USING HOT KEY (DOWNLOAD)Probe alarms P1 and P2 start some seconds after the fault in the related probe; they automatically stop some seconds after the probe restarts normal operation. Check connections before replacing the probe. Temperature alarms HA and LA automatically stop as soon as the temperature returns to normal values.Alarms EA and CA (with iF=bL) recover as soon as the digital input is disabled.15.1 ALARM RECOVERY6.1 THE REGULATION OUTPUT (Only for XR01CX)11.4 SWITCHING SECOND RELAY ON (iF=Au) (Only XR03CX)When o1=Au it switches on and off the second relay.It signals the door status and the corresponding relay output status through the dC parameter: no = normal (any change); Fn = Fan OFF; CP = Compressor OFF; FC = Compressor and fan OFF. Since the door is opened, after the delay time set through parameter di , the door alarm is enabled, the display shows the message dA and the regulation restarts if rd = y. The alarm stops as soon as the external digital input is disabled again. With the door open, the high and low temperature alarms are disabled.1. Turn OFF the instrument;2. Insert a programmed Hot Key into the 5 PIN receptacle and then turn the Controller ON;3. Automatically the parameter list of the Hot Key is downloaded into the Controller memory, successfully followed by appear En l abel;4. A fter 10 seconds the instrument will restart working with the new parameters;5. Remove the Hot Key.NOTE : the Er message is displayed for failed programming. Check the Hotkey connection, check the data into Hotkey and repeat the actions above..8.1 FANS AND DIGITAL INPUT When the digital input is configured as door switch iF=do , fans and compressor status depends on the dC parameter value: dC=no normal regulation;dC=Fn fans OFF;dC=cP compressor OFF; dC=Fc compressor and fans OFF.When rd=y , the regulation restart with door open alarm.3. DIMENSIONS AND CUT OUT 4. CONNECTIONS2. FRONT PANEL 6. REGULATION 8. FANS (Only XR06CX)7. DEFROST 11. DIGITAL INPUTS 13. ELECTRICAL CONNECTIONS 12. INSTALLATION AND MOUNTING 16. TECHNICAL DATAXR01CX ‑ XR02CX ‑ XR03CX ‑ XR04CX ‑ XR06CX To display target set point, in programming mode it selects a parameter or confirm an operationTo start a manual defrost In programming mode it browses the parameter codes or increases the displayed valueIn programming mode it browses the parameter codes or decreases the displayed valueKEYS COMBINATIONTo lock or unlock the keyboardTo enter in programming mode10. FRONT PANEL COMMANDS 10.6 HIDDEN MENU 9. VOLTAGE PROTECTION (Option)The HLVD function provides an alarm if the voltage of the power supply out of the normal range vU and vL .Parameters vc enable this function. vU and vL define the limitation threshold of the power, and if the voltage out of the range, the alarm will be triggered. Then the system will go to the dedicate action according to the parameter vr . • vr=n the regulation not stop • vr=y the regulation stop When the power back to the normal range, then alarm disappeared, the system will start to run the normal regulation.The hidden menu includes all the parameters of the instrument.HOW TO ENTER THE HIDDEN MENU1. Enter the Programming mode by pressing the SET + keys for 3s (Set value starts blinking);2. Released the keys, then push again the SET + keys for more than 7s. The L2 label will be displayed immediately followed from the Hy parameter. NOW YOU ARE IN THE HIDDEN MENU.3. Select the required parameter;4. Press the SET key to display its value;5. Use or to change its value;6. Press SET to store the new value and move to the following parameter.To exit : Press SET + or wait 15s without pressing a key.NOTE1: if none parameter is present in L1, after 3s the nP message is displayed. Keep the keys pushed till the L2 message is displayed. NOTE2: the set value is stored even when the procedure is exited by waiting the time‑out to expire.HOW TO MOVE A PARAMETER FROM THE HIDDEN MENU TO THE FIRST LEVEL AND VICEVERSA.Each parameter present in the HIDDEN MENU can be removed or put into “THE FIRST LEVEL” (user level) by pressing SET + . In HIDDEN MENU when a parameter is present in First Level the decimal point is on.1. Program one controller with the front keypad;2. When the controller is ON, insert the Hot key and push key; the uP message appears followed a by flashing En ;3. Push SET key and the En will stop flashing;4. Turn OFF the instrument remove the Hot Key, then turn it ON again.NOTE : the Er message is displayed for failed programming. In this case push again key if you want to restart the upload again or remove the Hot key to abort the operation.14.1 HOW TO PROGRAM THE HOT KEY FROM THE INSTRUMENT (UPLOAD)14. HOW TO USE THE HOT KEY Model XR01CX , in 32x74x50 mm short format , is a single stage temperature thermostat suitable for applications in the field of refrigeration or heating. It provides a relay output to drive the compressor. It is also provided with 1 NTC probe input and one digital input. The instrument is fully configurable through special parameters that can be easily programmed through the keyboard or by the HOTKEY.Model XR02CX , in 32x74x50 mm short format , is a digital controller with off cycle defrost designed for refrigeration applications at normal temperature. It provides a relay output to drive the compressor. It is also provided with 1 NTC probe input and one the digital input. The instrument is fully configurable through special parameters that can be easily programmed through the keyboard or by the HOTKEY.The XR03CX , in 32x74x50 mm short format , is microprocessor based controller suitable for applications on normal temperature refrigerating units. It provides two relay output: one for compressor and the other one for alarm signalling or as auxiliary output. It provides an NTC probe input and a digital input for alarm signalling, for switching the auxiliary output or for start defrost. The instrument is fully configurable through special parameters that can be easily programmed through the keyboard or the by HOTKEY.The XR04CX , in 32x74x50 mm short format , is microprocessor based controller suitable for applications on normal or low temperature refrigerating units. It provides two relay output: one for compressor and the other one for defrost. It provides two NTC probe inputs, one for room temperature and other one to control defrost termination. The instrument is fully configurable through special parameters that can be easily programmed through the keyboard or by the HOTKEY.Purpose of Control Operating ControlConstruction of Control Incorporated control intended to be used within Class I and Class II equipmentHousingSelf extinguishing PCCase Frontal 32×74mm; depth 50 or 60mm Mounting Panel mounting in a 71×29mm panel cut‑out Protection Rear: IP20 (EN60529) Frontal: IP65(EN60529), type 1 enclosure (UL 50e)Connections Screw terminal blocks 2,5mm2 wiring Power Supply According to the model: 12Vac/dc, ±10%; 230Vac 10%, 50/60Hz, 115Vac 10%, 50/60HzPower Absorption 3,5 V AmaxDisplay 2 digits, red LED, 14,2 mm high Digital Input Free voltage contact Data Storing on the non‑volatile memory (EEPROM)Type of Action 1.B Pollution Degree 2Software Class ARate Impulsive Voltage 2500V for 115Vac and 230Vac Models 500V for 12V models Over voltage Category II Operation T emperature 0÷60 °C (IEC/EN 60730‑1), ‑20÷60 °C (UL 60730‑1 – CAN/CSA E60730‑1)Storage Temperature ‑20÷60 °C (UL 60730‑1).Relative Humidity 20÷85% (no condensing).Measuring and Regulation RangeNTC ‑40÷110°C (‑40÷230°F), resolution 0,1 °C or 1°C or 1 °F (selectable).Accuracy (Ambient temp. 25°C): ±0,7 °C ±1 digit.Relay Outputs Tel:****************************************•请将说明书放在温控器附近,以便在需要时能够尽快查阅。
枫叶_小精灵ESPRIT报警系统用户操作说明书.
枫叶(小精灵ESPRIT+)报警系统用户操作说明书基础篇图1: 646键盘----用户与报警系统的沟通介面绿灯: 亮=所有防区处于正常状态(如所有门窗关好,装有探头的房间没人走动)灭=有防区处于开路或触发状态闪亮=报警系统处于退出延时状态红灯: 亮=报警系统布防故障键: 亮=系统有故障报警记忆键: 亮=系统有报警记忆-24”防区指示忆键: 亮=该防区处于开路或触发状态注: 按[2ND]即将“1-12”转为“13-“AC”橙灯: 亮=有交流电灭=无交流电使用键盘除了要认真观察键灯状态,还需熟识键盘发出的声音: 1、每次按键都应有键亮并发出单音;2、输入信息后键盘发出的间断性声音(BEEP-BEEP-BEEP)表示接收或确认;3、输入信息后键盘发出的连续性声音(BEEEEEEEP)表示拒绝或操作不当;精简操作篇一、布防(出门,家里无人)当绿灯亮,即所有防区处于正常状态时可进行布防。
输入密码即可,此时红灯亮绿灯闪亮,键盘发出BE-BE-BE---声音),报警系统处于退出延时状态,您应在退出延时时间内出门(最后10秒,声音急速)。
例:用户密码为1234,则布防时输入1234即可,此时红灯亮。
二、撤防(进门)您在进门后,触发延时防区(键盘发出BE--------声音),必须在规定的进入延时时间内输入密码撤防,此时红灯灭。
例:密码为1234,则输入1234, 此时“ARMED”灯灭,报警系统撤防。
三、报警时处理当报警系统报警时,您输入密码即可消除报警声,同时报警主机撤防。
例:密码为1234,输入1234即可。
四、设定用户密码密码可以选择4位数字或6位数字,本公司均选用4位数1、按[ENTER]+ [第一用户密码](已设为1234)键盘会发出确认声且[ENTER]键闪烁;2、按您所要输入的密码代号([01]- [48]),键盘会发出确认声且[ENTER]常亮;3、输入密码4位数(如删除密码,则输入[2ND]),按[ENTER]键,此时[ENTER]灯闪烁,你可重复第2步继续输入其它密码或按[CLEAR]退出。
(2021年整理)单片机小精灵使用说明
(完整版)单片机小精灵使用说明编辑整理:尊敬的读者朋友们:这里是精品文档编辑中心,本文档内容是由我和我的同事精心编辑整理后发布的,发布之前我们对文中内容进行仔细校对,但是难免会有疏漏的地方,但是任然希望((完整版)单片机小精灵使用说明)的内容能够给您的工作和学习带来便利。
同时也真诚的希望收到您的建议和反馈,这将是我们进步的源泉,前进的动力。
本文可编辑可修改,如果觉得对您有帮助请收藏以便随时查阅,最后祝您生活愉快业绩进步,以下为(完整版)单片机小精灵使用说明的全部内容。
(完整版)单片机小精灵使用说明编辑整理:张嬗雒老师尊敬的读者朋友们:这里是精品文档编辑中心,本文档内容是由我和我的同事精心编辑整理后发布到文库,发布之前我们对文中内容进行仔细校对,但是难免会有疏漏的地方,但是我们任然希望 (完整版)单片机小精灵使用说明这篇文档能够给您的工作和学习带来便利。
同时我们也真诚的希望收到您的建议和反馈到下面的留言区,这将是我们进步的源泉,前进的动力。
本文可编辑可修改,如果觉得对您有帮助请下载收藏以便随时查阅,最后祝您生活愉快业绩进步,以下为 <(完整版)单片机小精灵使用说明> 这篇文档的全部内容.单片机小精灵使用说明小液晶与大液晶在手动输入汉字时常常到不到对应的区位码与国标内码,我们为您提供单片机小精灵这个软件,它有一项工具可以帮助您查询TC3000系列产品的注释编码(包括小液晶与大液晶)具体操作如下:运行软件如下图:选择【其他辅助工具】如图中1所示在2处输入汉字,单击【转换】小液晶:在区位码(GBC )处的十进制数就是小液晶的区位码。
如图3所标示。
大液晶:在GBK 内码处的十六进制数就是大液晶的国标字库码.如图4所标示。
如上图所示:“汉”的小液晶区位码是:2626;大液晶的GBK 内码为:BABA即在小液晶上手动输入汉字“汉"时,只要输入2626即可,在大液晶上手动输入汉字“汉”时要输入BABA.说明:1 234所有的英文字母、数字、汉字、空格都要使用全角,只有大液晶的数字可以使用半角输入,否则在主机中显示乱码。
小精灵控制表说明书
直到出现参数“HY”,
按
出现参数“Pr2”,按
出现“PAS”,再按
出
现“---”,输入密码“321”,按
,这样就进入到 Pr2 层。
2、探头类型选择 “Pbc”
默认参数:“Pt1”
进入到 Pr2 层,通过按
或
找到参数“Pbc”
可设置参数:ntc、Pt1。
3、温度报警设置 “ALC” “ALU” “ALL” “ALd”
点为 SAA+HY,(HY 为偏差)
当 ACH=CL 时,打开输出的设定点为 SAA+HY,关闭输出的设
定点为 SAA。
4、Arp 辅助继电器探头选择(单位:℃) 默认参数:nP
nP:无探头,通过按钮开关辅助继电器; P1:探头 1(库温探头); P2:探头 2(蒸发器探头); P3:探头 3(辅助探头)。 六、通讯部分参数
精确到个位6p2p是否使用蒸发器探头2号探头n不使用y使用7p3p是否使用辅助探头3号探头n不使用y使用四呼救部分参数设定1did数字输入报警确认时间间隔单位
小精灵控制表操作 说明书
一、 接线图
二、 按键说明 1、 单按键说明 .
2、组合键说明
三、温度监控部分参数设定
1、进入 Pr2 层
在温度显示界面,长按
①进入到 Pr2 层,找到参数“ALC”(温度报警设置)
rE: 高温报警值是 ALU+SET,低温报警值是 SET-ALL
Ab:高温报警值是 ALU,低温报警值是 ALL
默认设置:“rE”,
可设置参数:rE、Ab。
②ALU 高温报警设定值(单位:℃) 默认参数:10℃
当 ALC=rE 时,ALU 可设定值为 0~50℃
深圳源控GPS定位追踪器XL06规格功能说明书
XL-T06 产品规格书及功能说明产品概述XLT-06型车载机体积小巧、功能强大、稳定性能好,价格适中、可靠性高,特别适合家用轿车、公司车辆、政府单位车辆、租赁车辆、摩托车等。
具有安装方便,使用操作简单、隐蔽性好、实用性强。
是我司结合多年对车载电子系统和GPS产品的研发经验所开发出的目前市场最小的一款GPS车载定位监控设备。
GPS车辆定位监控系统作用1﹑有力地保护企业单位﹑个人的车辆和人身安全。
2、预防和打击对车辆进行违法、犯罪,提高破案率。
3、能减少车辆盗抢事件、寻回被盗车辆,降低保险赔付。
4、随时随地对车辆进行调度和监控管理。
5、方便私家车主及单位用户,短信或者网上定位查询监控车辆。
功能说明一、 SMS短信监控1、监控手机号码设置2、密码保护3、授权电话号码的设置(系统可设置2个授权电话号码)4、电话监听5、开启/关闭报警功能6、车主手机定位7、开启/关闭自动上传信息8、设置自动上传信息间隔9、断油断电(/恢复油路电路)10、设置/取消超速报警11、断电报警11、断电报警9、断油断电(/恢复油路电路)10、设置/取消超速报警11、断电报警12、电子围栏报警13、外接摄像头拍照14、外接LED广告屏15、外接油量检测传感器16、产品图片:产品配件GPS 主机1台GSM天线1条GPS天线1条4PIN电源线1组断电器1套(配件)紧急报警监听线1条(配件)高温锂电池1个(配件)多功能线1条(配件)4PIN电源线1组紧急报警监听线1条(配件)双面胶贴一对面板螺丝1套SIM卡托盘1个保修卡1张整机主要技术参数工作电压: 9~32V/DC (可以直接接12V或者24V车辆)电源抗反接特性:≥80V工作状态: DC 12V (≤110 mA)待机状态:DC12V(≤45 mA)终端尺寸: 80 X 57 X 25(厚)mm重量:0.26kgGSM频段:900MHz/1800 MHz/1900 MHzGPS性能指标接收板结构:车载机模组 24通道定位精度:< 10米(95%);冷启动时间:< 48秒(平均)温启动时间:< 38秒(平均)热启动时间:< 8 秒(平均)天线:有源微带遍平天线工作温度:-10℃~+70℃工作湿度:5%-95%存储温度:-25℃~+85℃安装简图。
XiRi6血氧采集模块说明书
欣蕊6(XiRi6)血氧采集模块说明书 V1.0 一、 特点z最小尺寸,最便宜的血氧模块,三件套才200元。
z边沿有类似血氧模块的半孔,可直接焊在你的PCB板上。
z血氧和脉率测试稳定可靠,血氧线采样双层屏蔽,有证书。
z有技术支持,提供PC测试源代码(VC)三件套:血氧模块,血氧线,转接内组件血氧空板,PC端演示程序(提供VC源码)二、 参数规格SpO2测量范围:0-100%SpO2测量精度:±2%( 70-100%),低于70%不定义PR测量范围:25-250BPMPR测量精度:±2%或2BPM供电电压: 3.6-5.5V供电电源负载能力: 100mA供电电源纹波: RMS <50mV平均工作电流: 15mA(包含探头工作电流)三、 外形尺寸和接口定义长*宽*高=38mm *28 mm *9.5mmJ2管脚定义:序号 功能 描述1 VDD5V 电源正,3.6‐5.5V2 GND 电源地3 GND 电源地4 TXD 串口输出,电平为3.3V,串有100Ω电阻5 RXD 串口输入,电平为3.3V,串有100Ω电阻J1管脚定义:序号 功能 描述1 PD+ 接收管阳极2 PD‐ 接收管阴极3 IR‐ 红外发射管阴极4 IR+ 红外发射管阳极5 Shield 接屏蔽线6 DET 保留四、 通讯协议模块与上位机采用3.3V电平串口通讯,波特率115200,1位起始位,8位数据位,1位停止位,无校验位。
2.1数据包共5个字节,先发Byte0,最后发Byte4。
每隔4ms自动发送一次。
Btye0 Byte1 Byte2 Byte3 Byte4包头 数据高8位 数据低8位 峰值点+棒图 校验和0000,xyzm 1xxx,xxxx 1yyy,yyyy 1zzz,zzz 1mmm,mmmm z Byte0:为包头,高4位全为0,bit3为Byte1的bit7,bit2为Byte2的bit7,以此类推。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
小精灵微型电子温控器(压缩机、融霜、蒸发器风扇控制)XR06CX1. 目录1.目录 _____________________________________________________________________________ 12.注意事项_________________________________________________________________________ 13.概述 _____________________________________________________________________________ 14.融霜 _____________________________________________________________________________ 15.风扇 _____________________________________________________________________________ 16.面板的键盘操作 __________________________________________________________________ 17.参数 _____________________________________________________________________________ 28.数字开关量输入 __________________________________________________________________ 29.安装与固定______________________________________________________________________ 210.电气连接_________________________________________________________________________ 211.如何使用编程钥匙 ________________________________________________________________ 212.报警信号_________________________________________________________________________ 213.技术参数_________________________________________________________________________ 314.接线图___________________________________________________________________________ 315.参数表及出厂设定值______________________________________________________________ 3 2. 注意事项请在使用前详细阅读本说明书•请将说明书放在温控器附近,以便在需要时能够尽快查阅。
•请不要将温控器用于非下述目的以外的情况;不能作为安全保护设备使用。
•请在使用前检查应用范围的限定。
安全提示•通电前请检查电源电压是否正确。
•不要让温控器在有水或潮湿的环境中使用:温控器只能在使用环境限定的条件下使用,应避免在高湿度环境下温度的剧烈变化而使得水蒸气凝结在内部的电路板上。
•注意:在检修前请断开温控器电源,最好断开所有连接线路,以防止意外发生。
•探头要固定在使用者不易碰到的地方,非专业人员请勿擅自打开温控器外壳。
•一旦发现有故障或不能正常控制时,请将温控器和详细的故障描述一起发送到帝思·小精灵的代理商或帝思中国代表处(北京),联系方式见本说明书结尾处。
•应用时请注意每一个输出继电器触点的最大允许瞬时电流和额定电流(参见技术数据) •请确保探头的连接电缆与电源、负载输出电缆分开,并保持适当间距,不要交叉或缠绕。
•如果应用到工业环境中,请在温控器的电源上并联一个电源滤噪器(我们的型号为:FT1)。
3. 概述XR06CX:外形尺寸 32 x 74 x60 mm为适用于中/低温强制风冷制冷系统微型温度控制器,有三路输出:一路压缩机、一路蒸发器风扇和一路融霜(电热或热气),有两路NTC探头输入:一路为库温、一路为蒸发器温度( 融霜终止温度+风扇停止温度控制),一路无源数字开关量输入;可通过面板上的键盘设定或编程钥匙(HOT KEY)快速拷贝参数。
压缩机输出的状态依据探头测得的温度,当温度大于等于设定值(SET)+温差( Hy)压缩机输出触点闭合,压缩机运转;当温度小于等于设定值(SET)时压缩机输出触点断开,压缩机停止运转。
注:一旦温度探头失灵(未可靠连接或损坏)压缩机按照参数“Cy” 和“Cn” 所设定的运转时间和停止时间以固定开停比的方式来运行。
4. 融霜参数“td” 给定融霜类型:•td=EL→电热融霜 (融霜时压缩机输出继电器断开)•td=in →热气融霜(融霜时压缩机输出继电器闭合).其他参数还有:参数“id” 给定融霜时间间隔,即多长时间融霜一次;而融霜持续最大时间是由参数“Md”来给定的;参数“dE” 给定融霜终止温度;需要说明的是:无论“Md” “dE”哪一个条件到了都会退出融霜,而一般情况以“dE”退出、“Md”为防止融霜过度保护为好;在融霜结束后可以设定一个滴水时间,由参数“dt”来设定,当dt=0时意味着无滴水过程。
5. 风扇参数FC有如下选择来确定风扇的运行模式:•FC=cn →风扇与压缩机同开同停,融霜时停止•FC=on →风扇除了融霜期间停止外,其它时间一直运行融霜结束后可以通过参数“Fd”设定一个与滴水时间相对应的风扇启动延时时间•FC=cy →风扇与压缩机同开同停,融霜期间运转•FC=oy→风扇持续运转(包括融霜期间)另一个参数“FS”可以设定一个温度,当检测蒸发器探头的温度超过这个温度时风扇总是停止的,只有温度低于这个温度时,风扇才能运转,气流才可以流动起来,确保在蒸发器温度较高时不把热量带给库内的空间。
6. 面板的键盘操作在非编程状态下,按一次可显示目标设定值,在编程状态下可用来选择某一参数或确认一个操作在非编程状态下,可以启动一次手动融霜(前提是蒸发器温度探头测得的值必须小于参数“dE”的设定值)在编程状态下,可以向下浏览参数编码或增加参数值AUX在编程状态下,可以向上浏览参数编码或减小参数值组合键的功能+锁定或解锁键盘+进入编程模式+退出编程模式,恢复到设备温度显示状态LED图标状态含义一直亮正在制冷,压缩机输出触点闭合闪烁正处于防频繁启动延时等待时间(按Ac参数)一直亮正在融霜,融霜输出触点闭合闪烁正在融霜后滴水一直亮风扇正在转动,风扇输出触点闭合闪烁正处于融霜后启动延时等待时间一直亮测量单位显示闪烁处于编程模式一直亮测量单位显示闪烁处于编程模式如何查看设定值1.按下并立即放开SET 键,设定值被显示在屏幕上;2.按下并立即放开SET 键,等待5秒钟后恢复到正常显示状态。
如何修改设定值1.持续按下SET 键 2秒钟;2.设定值将被显示出来,并且“°C” 或“°F” LED图标灯开始闪烁;3.在10秒钟内,通过按或键来修改设定值。
4.要存储新的设定值可再按一次SET 键或者等待10秒钟。
如何启动一次手动融霜持续按下键超过2秒钟,就可以启动一次手动融霜(前提是蒸发器温度探头测得的值必须小于参数“dE”的设定值)。
如何修改参数值(进入用户层,第一层)修改参数值的操作如下:1.持续按下SET+ 键超过3秒钟进入编程状态(“°C” 或“°F”LED图标闪烁)。
2.选择需要的参数,再按“SET”键来显示显示参数值。
3.用或键来修改参数值。
4.再按“SET”键来确认并存储新值,紧接着会显示下一个参数名称。
.退出:按下并立即放开SET+ 组和键或不按任何键等待15秒。
.注意:不按任何键等待15秒退出时,新值也会被存储。
隐藏参数(第二层)进入隐藏参数层可以浏览到温控器的所有参数。
如何进入隐藏参数层1.首先持续按下SET+ 组合键超过3秒进入(第一层)编程状态(“°C” 或“°F”LED图标灯闪烁)。
2.释放上述组合键,然后再持续按下SET+ 键超过7秒钟,L2字符会一闪而过,紧接着Hy参数会显示出来。
此时您已经进入隐藏参数层。
3.选择需要的参数。
4.按“SET” 键显示其参数值。
5.用或键来改变其值。
6.再按“SET”键存储新值,紧接着会显示下一个参数名称。
退出:按下并立即放开SET+ 组和键或不按任何键等待15秒。
注1:如果在用户层(第一层)没有一个参数,在进入第一层3秒钟后会显示“nP” 字符信息,持续按下上述组合键直到 L2字符出现后进入第二层参数。
注2:不按任何键等待15秒退出时,新值也会被存储。
如何将参数从隐藏层(第一层)移到用户层(第二层)或则反过来。
在进入隐藏参数层后,每一个位于隐藏层的参数都可以通过按SET+ 组合键移到用户层,当原来位于用户层的参数在隐藏层里显示时,该参数名称中会有一个小数点点亮。
键盘锁定1.持续按下 + 组合键超过 3秒钟。