Commscope, Inc. 电缆保护设备清单说明书

合集下载
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

2
3
029 6
6 010 6 013
028 6
026 6
027 6
4
025 6
COMMSCOPE,
C
© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPRIATARY PROPERTY OF COMMSCOPE, INC.AND MAY BE USED ONLY FOR THE SPECIFIC PURPOSE AUTHORIZED IN WRITING BY COMMSCOPE, INC.
2
3
016
CABLE CLAMP COVER
13
017
SCREW 6-32X3/4
2
018
CABLE CLAMP BRACKET
1
019
SCREW 6-32,.250 POU
2
FRONT VIEW - 2RU WITH 23" MOUNTING BRACKETS
(96 POS ADAPTER PLATES SHOWN FOR REFERENCE)
4
6 VCG SYSTEM CAN ONLY BE INSTALLED WHEN THE MOUNTING
029
6-32,.250 SCREW
44
BRACKETS ARE ON 5" OR 8" POSITIONS.
REAR VIEW
.69
1.00 REF
© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPRIATARY PROPERTY OF
2
SEE DETAIL D
022 SEE DETAIL C
DETAIL B SCALE 0.800
3
4 A
008 009
B
C
001 002 OR 003 OR 004 OR 005 006 007
DETAIL D SCALE .750
D
018 020 019
015
1
016
017
DETAIL C
SCALE 1.000
TITLE
INSTALLATION DWG FPX 2RU AFA 12" DEPTH
ALL DIMS AND TOLERANCES .XX: #N/A
INC.ARE INCHES UNLESS
.XXX: #N/A
OTHERWISE SPECIFIED ANGULAR: #N/A
C
DRAWING NUMBER
TITLE
INSTALLATION DWG
COMMSCOPE, INC.AND MAY BE USED ONLY FOR THE SPECIFIC PURPOSE AUTHORIZED IN WRITING BY
FPX 2RU AFA 12" DEPTH
COMMSCOPE, INC.
ALL DIMS AND TOLERANCES .XX: #N/A
SHT. 1 OF
3
A
B
C
DIMENSIONS IN INCHES THIRD ANGLE PROJECTION
A 1
2
B
C
D
PANEL GROUNDING
EACH PANEL HAS A GROUNDING LOCATION MARKED WITH THE STANDARD GROUNDING SYMBOL. THIS LOCATION IS ON THE RIGHT SIDE OF THE PANEL AS SHOWN IN FPX 2RU PANEL DIAGRAM. USE THE TWO #10-32 GROUND SCREWS (ITEM 011) AND TWO #10 STAR WASHERS (ITEM 012) PROVIDED TO CONNECT A #6 COPPER GROUNDING CABLE TO THE PANEL. GROUND THE UNIT TO THE LOCAL FACILITY GROUND BUS PER LOCAL PRACTICE. A TWO-HOLE GROUNDING LUG IS SHOWN IN FIGURE FOR REFERENCE.
2. GROUND SCREWS ARE TO BE TORQUED AT 40 IN-LIB
3. THE FIBER PANEL NEXT GENERATION IS DESIGNED TO BE INSTALLED IN AN ENVIRONMENTALLY CONTROLLED NETWORK TELECOMMUNICATIONS FACILITY SUCH AS A CENTRAL OFFICE, CONTROLLED ENVIRONMENTAL VAULT, OR DATA CENTER.
007
CLAMP SCREW
4
008
SCREW 12-24X.5
4
009
#12 WASHER
4
FRONT VIEW
12.00 REF
010
WASHER
8
011
10-32 MACHINE SCREW
2
012
GROUND WASHER
2
RIGHT VIEW
013
6-32 SCREW
8
015
CLAMP YOKE
A
B
SEE DETAIL A
3
ISO REAR VIEW
SHOWN WITH COVERS REMOVED
DETAIL A SCALE 1.300 GROUNDING LOCATION
4
COMMSCOPE,
C
© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPRIATARY PROPERTY OF COMMSCOPE, INC.AND MAY BE USED ONLY FOR THE SPECIFIC PURPOSE AUTHORIZED IN WRITING BY COMMSCOPE, INC.
SIZE
300100105893
D
REV
DO NOT SCALE DRAWING ENGR: HECTOR UREÑO DWN: ASAHEL SALCEDO
SHT. 2 OF
3
DIMENSIONS IN INCHES THIRD ANGLE PROJECTION
A
B
SEE DETAIL B
1
021 023
SHOWN WITH FRONT DOOR REMOVED
020 NOTES:
021
1. PANEL CAN BE MOUNTED AT 2", 5" OR 8" DEPTHS IN 19" OR 23"
.437 X .250
RACKS USING WECO OR EIA PATTERNS.
022
SLOT REF
SIZE
300100105893
D
REV
DO NOT SCALE DRAWING ENGR: HECTOR UREÑO DWN: ASAHEL SALCEDO
SHT. 3 OF
3
DIMENSIONS IN INCHES THIRD ANGLE PROJECTION
2
TOP VIEW
4
CABLE ENTRIES (BOTH SIDES)
003 GROMMET, CABLE CLAMP .60 2 004 GROMMET, CABLE CLAMP .50 2 005 GROMMET, CABLE CLAMP .40 2
006
CLAMP COVER
2
3.42 REF
TITLE
INSTALLATION DWG FPX 2RU AFA 12" DEPTH
ALL DIMS AND TOLERANCES .XX: #N/A
INC.ARE INCHES UNLESS
.XXX: #N/A
OTHERWISE SPECIFIED ANGULAR: #N/A
C
DRAWING NUMBER
2
GROUNDING TERMINAL
2
SPIRAL WRAP 5
4FT
VCG
2
1.75 REF
4 POLYCARBONATE FRONT DOOR. 5 USE FOR CABLE RIBBON ENTRY.
026
CABLE SHIELD
2
027
EDGE PROTECTOR
10
028 SHIELD MOUNTING BRACKET 2
A
B
C
D
REV
MCO
DWN
DATE
C
C 40023779MCO LASR 07-AUG-15
D 40023779MCO SC
22-AUG-16
1
1
2.00 REF
PART LIST
17.00
ITEM
DESCRIAMP YOKE
4
002 GROMMET, CABLE CLAMP .70 2
023
2. REMOVE VERTICAL CABLE GUIDE FOR 2" RECESS MOUNT.
024
3. CABLE CLAMP IS INCLUDED WITH CHASSIS (0.4 - 0.7) O.D.
025
STANDOFF
2
WASHER FLAT 1/4 SS
2
N125-00 1/4-20
COMMSCOPE, INC.ARE INCHES UNLESS
.XXX: #N/A
OTHERWISE SPECIFIED ANGULAR: #N/A
C
DRAWING NUMBER
SIZE
300100105893
D
REV
DO NOT SCALE DRAWING ENGR: HECTOR UREÑO DWN: ASAHEL SALCEDO
1
ALL PANEL IS BUILDING WITH SCREWS THREAD-FORMING WITH NIBS IN ORDER TO CUT THE PAINT AND GROUND ALL WALLS OF PANEL.
NOTES:
1. GROUND THE UNIT TO THE LOCAL FACILITY CBN (COMMON BONDING NETWORK) OR IBN (ISOLATED BONDING NETWORK) PER LOCAL PRACTICE.
022
021
2
3
2-HOLE LUG TERMINAL
HOLE CENTER SPACING 0.625 INCHES
4
STRIP BACK INSULATION
PER LUG MANUFACTURER'S
RECOMMENDATION
#6 COPPER WIRE
GROUND CABLE AND 2-HOLE LUG TERMINAL
相关文档