各种氯离子含量测定方法的适用性探讨及新方法的提出

合集下载

氯离子测定方法及其应用研究

氯离子测定方法及其应用研究

西部皮革第31卷收稿日期:2009-06-01第一作者简介:俞凌云,女,(1982-),博士研究生,研究方向:现代分离分析方法与理论。

*通讯联系人:张新申,男,(1951-),教授,博士生导师,研究方向:现代仪器分析。

氯离子测定方法及其应用研究俞凌云,朱娟,张新申*(四川大学制革清洁技术国家工程实验室,四川成都610065)摘要:氯离子是环境监测的一项重要指标。

皮革工业废水中氯离子含量很高,若不加处理直接排放,会对环境造成污染。

本文总结了国内近些年来常用的氯离子的测定方法及其应用。

关键词:氯离子;检测;应用;制革中图分类号:TS 57文献标识码:A文章编号:1671-1602(2009)15-0032-05Determination Method of Chloride and its ApplicationYU Ling-yun ,ZHU Juan ,ZHANG Xin-shen *(National Engineering Laboratory for Clean Technology of Leather Manufacture,Sichuan University,Chengdu 610065,China)Abstract:The chloride content is very high in the tannery effluents,and it is a very important index in environmental monitoring.High chloride content could cause environmental monly used methods of chloride determination and their applications were summarized in this paper.Key words:chloride;determination;application;tanning1前言氯化物[1]是制革过程中的一种重要的化工原料。

氯离子检测办法

氯离子检测办法

氯离子测定方法小结1、摩尔法测定范围适用于天然石、循环冷却水、以软化水为补给水的锅炉炉水中氯离子含量的测定测定范围为5mg/L~150mg/L。

测定原理以铬酸钾为指示剂在pH为5~9.5的范围内用硝酸银标准滴定溶液滴定。

硝酸银与氯化物作用生成白色氯化银沉淀当有过量硝酸银存在时则与铬酸钾指示剂反应生成砖红色铬酸银表示反应达到终点。

方法来源GB/T15453-2008工业循环冷却水和锅炉用水中氯离子的测定摩尔法注意事项测定终点因人而异误差较大。

2。

3-甲醇溶液4至100mL后测定。

测定原理在pH2.3~2.8的水溶液中氯离子与汞离子反应生成微解离的氯化汞。

过量的汞离子与二苯卡巴腙二苯偶氯碳酰肼形成紫色络合物指示终点可用汞盐滴定水样中氯化物含量。

指示剂中加溴酚蓝、二甲苯蓝-FF混合液作背景色可提高指示剂的灵敏度。

铁Ⅲ、铬酸根、亚硫酸根、联氨等对测定有一定干扰可加适量的对苯二酚或过氧化氢消除干扰。

方法来源GB6905.3-1986 锅炉用水和冷却水分析方法氯化物的测定汞盐滴定法注意事项水样混浊有较深颜色应过滤或脱色后再取样测定。

5、硫氰酸汞分光光度法测定范围适用于炉水中氯离子含量的测定测定范围为0mg/L~1.0mg/L和1.0mg/L~6.0mg/L测定原理在含氯离子的溶液中氯离子与硫氰酸汞发生反应生成氯化汞并释放出SCN-在高氯酸介质中Fe3与SCN-形成稳定的橘红色的络合物此络合物的呈色强度与氯离子的含量成曲线关系。

将吸光度与浓度进行曲线拟合经回归计算得回归方程。

并且该直线分成两段氯离子含量在01.0Cl-mg/L范围内成一直线关系氯离子含量在1.06.0?Cl-mg/L范围内成另一直线关系。

方法来源《氯离子含量测定方法的适用性探讨》注意事项需要额外配备分光光度计460nm波长、30mm和100mm吸收池。

6、离子色谱法测定范围适用于锅炉给水、凝结水、蒸汽和炉水等水样中阴离子的测定。

使用大容积样品定量环如1mL直接进样或浓缩柱预浓缩水样mg/L级阴7GB/T 9729-2007 化学试剂氯化物测定通用方法。

砂子中氯离子含量试验测定方法

砂子中氯离子含量试验测定方法

砂子中氯离子含量检测1.目的检测砂子中氯离子含量,指导检测人员按规程正确操作,确保检测结果科学、准确。

2.检测参数及执行标准砂子中氯离子含量执行标准:GB/T14684-2001《建筑用砂》3.适用范围适用于建筑工程中混凝土及其制品和建筑砂浆用砂。

4.职责检测员必须执行国家标准,按照作业指导书操作,随时作好试验记录,填写检测报告,并对数据负责。

5.样本大小及抽样方法同一规格产地,每验收批取样部位应均匀分布,将表面层铲去,然后由8个部位取大致等量的砂,组成一组样品,人工四分法缩分至所需试样。

用大型运输工具的,以400m3或600t为一验收批,用小型工具运输时,以200m3或300t为一验收批。

不足上述数量以一批论。

最少取样数量不少于80kg.并将试样缩分至约1100g,放在烘箱中于(105±5)℃下烘干至恒量,冷却到室温后,分为大致相等的两份备用。

6.仪器设备1.GY64鼓风烘箱(JC411):能使温度控制在(105±5)℃;2.HCTP12A天平(JC231):称量1000 g,感量0.1 g;3. 滴定管:10 ml或25 ml,精度0.1 ml;4. 容量瓶、移液管、三角瓶、磨口瓶、洗耳球;5.5%铬酸钾溶液指示剂、0.01mol/l硝酸银标准溶液。

7.环境条件常温下物理试验内进行。

8.检测步骤及数据处理1.取试样500g,精确至0.1g.将试样倒入磨口瓶中,用容量瓶量取500ml蒸馏水,注入磨口瓶,盖上塞子,摇动一次后,放置2h,然后每隔5min摇动一次,共摇动三次,使氯盐充分溶解。

将磨口瓶上部已澄清的溶液过滤,然后用移液管吸取50ml滤液,注入到三角瓶中,再加入5%铬酸钾溶液指示剂1ml,用0.01mol/l硝酸银标准溶液滴定至呈现砖红色为终点。

记录消耗的硝酸银标准溶液的毫升数,精确至1ml。

2.空白试验:用移液管吸取50ml滤液,注入到三角瓶中,再加入5%铬酸钾溶液指示剂1ml,用0.01mol/l硝酸银标准溶液滴定至呈现砖红色为终点。

氯离子检测方法精编WORD版

氯离子检测方法精编WORD版

氯离子检测方法精编W O R D版IBM system office room 【A0816H-A0912AAAHH-GX8Q8-GNTHHJ8】氯离子测定方法小结1、摩尔法测定范围适用于天然石、循环冷却水、以软化水为补给水的锅炉炉水中氯离子含量的测定测定范围为5mg/L~150mg/L。

测定原理以铬酸钾为指示剂在pH为5~9.5的范围内用硝酸银标准滴定溶液滴定。

硝酸银与氯化物作用生成白色氯化银沉淀当有过量硝酸银存在时则与铬酸钾指示剂反应生成砖红色铬酸银表示反应达到终点。

方法来源GB/T15453-2008?工业循环冷却水和锅炉用水中氯离子的测定摩尔法注意事项测定终点因人而异误差较大。

2、电位滴定法测定范围适用于天然石、循环冷却水、以软化水为补给水的锅炉炉水中氯离子含量的测定测定范围为5mg/L~150mg/L。

测定原理以双液型饱和甘汞电极为参比电极以银电极为指示电极用硝酸银标准滴定溶液滴定至出现电位突跃点即理论终点即可从消耗的硝酸银标准滴定溶液的体积算出氯离子含量。

方法来源GB/T?15453-2008?工业循环冷却水和锅炉用水中氯离子的测定电位滴定法注意事项需要额外配备电磁搅拌器、电位滴定计、双液型饱和甘汞电极、银电极。

溴、碘、硫等离子存在干扰。

3、共沉淀富集分光光度法测定范围适用于除盐水、锅炉给水中氯离子含量的测定测定范围为10μg/L~100μg/L。

测定原理基于磷酸铅沉淀做载体共沉淀富集痕量氯化物经高速离心机分离后以硝酸铁-高氯酸溶液完全溶解沉淀加硫氰酸汞-甲醇溶液显色用分光光度法间接测定水中痕量氯化物。

方法来源GB/T?15453-2008工业循环冷却水和锅炉用水中氯离子的测定共沉淀富集分光光度法注意事项需要额外配备分光光度计460nm波长、30mm吸收池、高速离心机转速5000r/min配有250mL聚乙烯离心管。

4、汞盐滴定法测定范围适用于天然水、锅炉水、冷却水中氯离子含量的测定测定范围为1mg/L~100mg/L超过100mg/L时可适当地减少取样体积稀释至100mL后测定。

氯离子的测定方法 (2)

氯离子的测定方法 (2)

氯离子的测定方法1、适用范围本方法规定了采用磷酸蒸馏-硝酸汞滴定法测定水泥及其原料中氯的化学分析方法。

本方法适用于水泥及其原料中的氯含量的测定。

2、方法提要用规定的蒸馏装置在250℃-260℃温度条件下,以过氧化氢和磷酸分解试样,以净化空气做载体,进行蒸馏分离氯离子,用稀硝酸做吸收液,蒸馏10min-15min后,用乙醇吹洗冷凝管及其下端于锥形瓶内,乙醇的加入量占75%(体积分数)以上。

在PH3.5左右,以二苯偶氮碳酰肼为指示剂,用硝酸汞标准滴定溶液进行滴定。

3、试剂3.1硝酸:密度1.39g/cm3-1.41 g/cm3或质量分数65%-68%;3.2磷酸,密度1.68g/cm3或质量分数≥85%;3.3乙醇,体积分数95%或无水乙醇;3.4过氧化氢,质量分数30%;3.5氢氧化钠溶液[c(NaOH)=0.5mol/L]:将2g氢氧化钠溶于100ml 水中;3.6硝酸溶液[c(HNO3)=0.5mol/L]:取3ml硝酸,用水稀释至100ml;3.7氯离子标准溶液准确称取0.3297g已在105℃-106℃烘2h的氯化钠,溶于少量水中,然后移入1L容量瓶中,用水稀释至标线,摇匀。

此溶液1ml 含0.2mg氯离子。

吸取上述溶液50ml,注入250ml容量瓶中,用水稀释至标线,摇匀。

此溶液1ml含0.04mg氯离子。

3.8硝酸汞标准滴定溶液[c(Hg(NO3)2)=0.001mol/L]3.8.1硝酸汞标准滴定溶液[c(Hg(NO3)2)=0.001mol/L]的配制称取0.34g硝酸汞[Hg(NO3)2·1/2H2O],溶于10ml硝酸中,移入1L容量瓶内,用水稀释至标线,摇匀。

3.8.2硝酸汞标准滴定溶液[c(Hg(NO3)2)=0.001mol/L]的标定用微量滴定管准确加入 5.00ml0.04mg/ml氯离子标准溶液于50ml锥形瓶中,加入20ml乙醇及1-2滴溴酚蓝指示剂,用氢氧化钠溶液调至溶液呈蓝色,然后用硝酸调至溶液刚好变黄,再过量1滴(PH 约3.5),加入10滴二苯偶氮碳酰肼指示剂,用硝酸汞标准滴定溶液滴定至紫红色出现。

关于测定混凝土中氯离子测定几种方法的探讨

关于测定混凝土中氯离子测定几种方法的探讨

关于测定混凝土中氯离子测定几种方法的探讨混凝土中氯离子含量的测定一直是建筑材料领域中一个备受关注的问题。

因为氯离子会对混凝土结构造成腐蚀,影响混凝土的耐久性和使用寿命。

准确测定混凝土中氯离子的含量对于评估混凝土的质量和耐久性至关重要。

目前,测定混凝土中氯离子含量的方法有多种,本文将对几种常用的方法进行探讨和比较,希望能够为混凝土中氯离子含量的测定提供一些参考。

一、银离子滴定法银离子滴定法是目前测定混凝土中氯离子含量最常用的方法之一。

其原理是通过向混凝土溶液中滴加标准银硝溶液,使氯离子和银离子发生沉淀反应,然后用钾铬酸钾指示剂指示沉淀结束点,从而计算出氯离子的含量。

银离子滴定法的优点是操作简便,结果准确可靠。

该方法需要用到大量的化学试剂和仪器设备,且操作过程中对实验人员的技术要求较高。

该方法只适用于氯离子浓度较高的混凝土样品,对于低浓度的氯离子样品则不够敏感。

银离子滴定法在一定程度上存在一定的局限性。

二、离子色谱法离子色谱法是利用离子交换色谱仪来测定混凝土中氯离子含量的一种方法。

该方法首先将混凝土样品溶解成溶液,然后利用离子交换色谱仪进行分离和检测,最终得出氯离子的含量。

离子色谱法的优点是操作简便,结果准确可靠,并且对于氯离子浓度较低的样品也有较高的检测灵敏度。

该方法还可以同时检测多种离子,具有分析多种成分的能力,因此在实际应用中具有很高的灵活性。

离子色谱法也存在一些局限性,例如需要专门的仪器设备和昂贵的色谱柱,成本较高。

样品的制备过程较为复杂,需要有一定的化学分析基础和操作经验。

三、电化学法电化学法是一种通过电化学方法测定混凝土中氯离子含量的方法。

该方法利用电化学仪器对混凝土样品进行测试,通过对氯离子在电极上的电极反应进行测定和分析,得出氯离子的含量。

电化学法也存在一些局限性,例如对实验人员的技术要求较高,需要具有一定的电化学专业知识和实验经验。

该方法需要专门的仪器设备和电极材料,成本较高。

四、比较和总结银离子滴定法、离子色谱法和电化学法是目前测定混凝土中氯离子含量常用的几种方法。

石灰石中氯离子含量测定方法比较

石灰石中氯离子含量测定方法比较

石灰石中氯离子含量测定方法比较摘要:在水泥生产过程中,石灰石作为掺合料,其用量占水泥的比例非常大。

由于石灰石的物理化学性质决定了其自身不含氯离子,但当石灰石中有氯离子存在时,就会使水泥中氯离子的含量明显增加,从而导致水泥的安定性变差。

因此,石灰石中氯离子含量的测定也就成为了水泥质量检测的一个重要环节。

石灰石中氯离子含量的测定方法有很多,本文对磷酸蒸馏-汞盐滴定法和电位滴定法检测方法的实验原理、实验过程以及实验结果进行了详细的分析研究。

关键词:石灰石;氯离子含量;测定方法水泥中氯离子的存在会造成钢筋腐蚀,降低其强度,进而对混凝土的总体力学性质产生不利影响。

近年来,随着对混凝土耐久性研究的深入,氯盐侵蚀对混凝土结构的破坏作用引起了广泛关注。

而石灰石作为水泥的基础原料之一,其所含的氯离子含量是评价水泥原料好坏的一项重要标准。

因此,在生产中,对石灰石的化学成分控制、杂质的分离、氯离子含量的控制和检测等都是至关重要的。

生产实践表明,采用石灰石作原料时,必须对石灰石氯离子含量进行严格的控制,以防止氯离子含量过高造成质量问题。

1.实验原理1.1电位滴定法电位滴定法是以电极的电位为根据进行滴定的一种方法。

因其操作简单、灵敏度高、分析结果准确等优点,在溶液中的含量测定中得到了广泛应用。

在滴定开始之前,将电极浸入已知浓度的待测物质中,测量其电极电位与所用的试剂浓度之间的关系,即得到待测组分的电位值,然后根据滴定终点的颜色变化来确定滴定终点。

电位滴定法具有简便、精度高、精确性好等优点,但是受限于电极的敏感性,不适用于测定10-5 mol/L以下含有 Cl的液体,所以对于低 Cl含量的石灰石,需要加大样品的称重,并且在过滤过程中要严格控制洗涤液的容量,避免样品中Cl离子的浓度过低而降低电位测定的精度。

1.2磷酸蒸馏-盐滴定法它是一种通过磷酸的蒸馏来测定磷酸盐含量的方法。

试验过程为称取一定质量的试样,加入氢氧化钠溶液和硝酸银溶液,制成试液,然后用稀硝酸除去其中的铝和锰后,再加入铬酸钾溶液,用稀硝酸调节pH值至9~10,再将试液加热蒸馏至所需终点。

各种氯离子含量测定方法的适用性探讨及新方法的提出

各种氯离子含量测定方法的适用性探讨及新方法的提出
些 水 中氯离 子 的测 定 , 国家 标 准 及 电 力 行业 标 准 规 定
c O + 2 — Ag C O r; Ag 一 2 r
( 红 ) () 砖 2
了许 多测 试 方 法 , : 尔 法 、 位 滴 定 法 、 盐 滴 定 如 摩 电 汞 法 、 C 电极法 、 沉 淀 富集 分 光 光 度 法 、 子 色 谱 法 P 1 共 离
提供 了炉 水 中氯 离 子的测 定方 法 。
由于 Ag 1的 溶 解 度 ( . C 1 3× 1 mo/ 小 于 0 lL)
AgC O z r 的溶解 度 (. ×1 to/ , 据 分步沉 淀 6 5 0 o lL)根
1 摩 尔 法 测 定 氯 离 子 时产 生 的误 差
对 于 电厂 原水 中氯 离 子 含 量 的分 析 , 尔 法得 到 摩
c O 浓度 的乘 积 超 过 Ag C O r r 的溶 度积 时 , 出现 便
砖红 色 Ag C O 沉 淀 , zr 达到 滴定 的终 点 。 热 力
1 1 方 法 原 理 .
1 3 误 差 计 算 .
趸喜 o

水样 以铬 酸钾 为指试 剂 , 中性或 弱碱 性 条件 下 , 在
( 括 井 水 、 库水 、 包 水 自来 水 、 水 、 河 中水 等 ) 反 渗 透 出 、
用 硝酸 银标 准溶 液 进 行 滴 定 , 出现 砖 红 色 铬 酸银 沉淀 时 到达指 示 终点 。反 应如 下 :
c + Ag 一 Ag l l — c ( 色) 白 (汽等 。对于 这
等等 。每 种方 法都 规 定 了适 用 范 围 , 不 同 的水 质 氯 即 离子 含量不 同 , 适用 的测定方 法 不 同。然 而 , 则 现场 应

采用电位滴定仪测定含氯量方法的探讨

采用电位滴定仪测定含氯量方法的探讨

采用电位滴定仪测定含氯量方法的探讨1. 引言1.1 研究背景引言:在工业生产和环境监测中,准确测定含氯物质的量是至关重要的。

氯是一种常见的化学元素,广泛存在于洗涤剂、消毒剂、汽油等物质中。

在一些情况下,氯的含量过高可能会对人体健康和环境造成危害。

开发一种简便、准确的测定含氯量的方法成为了当今科研领域的重要课题之一。

目前,常用的测定含氯量的方法包括滴定法、光度法和电位滴定法。

滴定法需要使用显色剂,存在误差较大的可能;光度法对样品的处理要求较高,操作复杂;而电位滴定法则具有快速、准确的特点,被广泛应用于含氯物质的测定中。

本研究旨在探讨采用电位滴定仪测定含氯量的方法,通过了解电位滴定仪的原理和含氯物质的测定方法,以及实验步骤和结果分析,来评估其在实际应用中的可行性和优缺点,为今后的含氯量测定工作提供参考依据。

1.2 研究意义研究含氯物质的测定方法在工业生产、环境监测以及食品安全等领域具有重要意义。

含氯物质在实际生产和使用中广泛存在,其含量的准确测定对于保障产品质量和人类健康至关重要。

现有测定方法存在着诸多局限性,如对操作者技术要求高、测定时间长、且存在一定的误差等问题。

寻找一种快速、准确且简便的含氯量测定方法具有重要意义。

2. 正文2.1 电位滴定仪的原理电位滴定仪是一种常用于测定溶液中氯离子含量的仪器。

其原理基于电化学方法。

通常情况下,电位滴定仪由一个工作电极、一个参比电极和一个计量、控制系统组成。

工作电极通常是一个易氧化的金属电极,如银电极,参比电极则是一个稳定的电位电极,如饱和甘汞电极。

在测定氯离子含量时,首先将待测溶液与适量的标准氯化银溶液进行反应,生成沉淀,并通过对溶液中的氯离子进行电位滴定的方法,测定出溶液中氯离子的浓度。

在实际应用中,还需要考虑到电位滴定仪的参数设置、校准和数据处理等问题,以确保测定结果的准确性和可靠性。

电位滴定仪具有操作简便、准确度高、测定范围广等优点,因此在测定含氯量方面具有很大的应用价值。

结构混凝土中的氯离子含量问题探讨

结构混凝土中的氯离子含量问题探讨

结构混凝土中的氯离子含量问题探讨概要:只有各方工程质量责任主体在工程施工中做好氯离子含量的控制监督,才能杜绝钢筋混凝土工程氯离子含量超标的安全隐患。

深圳曾曝出居民楼房楼板开裂、墙体裂缝等问题,每逢雨天渗水不止。

而根据深圳市政府的调查结果显示,问题的根源就是建设时使用大量没有经过净化处理的海砂。

如果建筑用海砂不符合国家的强制标准,超标的氯离子含量将严重腐蚀建筑中的钢筋,造成重大的安全隐患。

1 氯离子侵入途径氯离子侵入混凝土有两种途径:其一是“内掺”,如掺用含氯离子外加剂,使用海砂,在含盐环境中拌制浇筑混凝土等;其二是“外掺”,环境中的氯离子通过混凝土的宏观、微观缺陷渗入到混凝土中,并达到钢筋表面。

一般环境下只考虑氯离子的“内掺”影响,氯离子的含量需要满足规范和设计要求。

而近海或海洋环境、除冰盐等其他氯化物环境(来自海水的除外)下,氯离子可以从混凝土表面迁移到混凝土内部。

当到达钢筋表面的氯离子积累到一定浓度(临界浓度)后,也能引发钢筋的锈蚀,所以在氯化物环境中,还需要考虑氯离子的“外掺”影响,并进行抗氯离子渗透性能的评定。

2 施工过程中氯离子含量的监督在施工过程中需做好对钢筋混凝土工程氯离子含量的监督工作。

首先,监理单位应检查原材料试验报告和施工单位提供的氯化物、碱的总含量计算书(见《混凝土结构工程施工质量验收规范》(2011年版)中条文7.2.3混凝土中氯化物和碱的总含量应符合现行国家标准《混凝土结构设计规范》和设计的要求)。

《混凝土质量控制标准》条文2.3.3钢筋混凝土和预应力混凝土用砂的氯离子含量分别不应大于0.06%和0.02%;混凝土用海砂氯离子含量不应大于0.03%(由于目前测定氯离子含量的制样方法,与工程中使用海砂的实际中的做法不相符,且会低估海砂中氯离子的含量,所以规范规定的海砂氯离子含量低于钢筋混凝土用砂的氯离子含量,见《海砂混凝土应用技术规范》)。

硅酸盐水泥氯离子含量不大于0.06%,钢筋混凝土拌合用水氯化物含量不大于1000mg/L(见《混凝土结构工程施工规范》附录F混凝土原材料技术指标)。

关于测定混凝土中氯离子测定几种方法的探讨

关于测定混凝土中氯离子测定几种方法的探讨

关于测定混凝土中氯离子测定几种方法的探讨
混凝土是一种常用的建筑材料,其中含有的氯离子含量对混凝土的性能和耐久性有着
重要影响。

准确测定混凝土中氯离子的含量对于混凝土的质量控制和工程使用具有重要意义。

目前,常用的混凝土中氯离子测定方法主要包括几种化学分析方法和仪器分析方法。

本文将对这些主要方法进行探讨。

一种常用的化学分析方法是氯离子络合滴定法。

该方法通过使用二恶英蓝作为指示剂,根据氯离子与络合试剂形成络合物的滴定反应来测定混凝土中氯离子的含量。

该方法操作
简单、准确度高,且可同时测定多种混凝土试件中的氯离子含量。

该方法需要使用大量的
试剂和仪器设备,并且反应时间较长,不适用于现场快速检测。

除了化学分析方法,一些仪器分析方法也被广泛应用于混凝土中氯离子的测定。

X射
线荧光光谱法(XRF)是一种非破坏性的分析方法,可以通过测量混凝土试件中X射线的荧光来测定混凝土中氯离子的含量。

该方法无需试剂和化学反应过程,操作简便,可实时快
速获得氯离子含量。

该方法需要高昂的仪器设备,并且需要专业的操作技术。

还有一些新兴的测定方法正在不断发展和研究中,如电化学方法、电导率测定法等。

这些方法具有操作简便、快速准确的特点,有望成为未来混凝土中氯离子测定的新选择。

混凝土中氯离子的测定方法有多种选择,每种方法都有其适用的场合和优缺点。

在实
际应用中,可以根据需要选择合适的方法进行测定。

对于提高测定方法的准确度和操作便
捷性,需要不断开展研究和改进,以满足实际工程需要。

如何使用氯离子含量快速测定仪

如何使用氯离子含量快速测定仪

如何使用氯离子含量快速测定仪如何使用氯离子含量快速测定仪1. 引言氯离子是很常见的环境分析参数之一,它在水质监测、土壤污染评估和工业生产过程等领域都具有重要意义。

如何准确、快速地测定氯离子的含量成为一个关键问题。

在本文中,我们将介绍一种使用氯离子含量快速测定仪进行测量的方法,并探讨其优点和局限性。

2. 方法和原理氯离子含量快速测定仪是一种基于电化学分析原理的设备,可以通过测量溶液中的氯离子浓度来确定样品中的氯离子含量。

具体而言,该仪器利用电极与溶液中的氯离子发生反应,产生电流信号。

根据法拉第定律,电流与氯离子浓度成正比关系,因此可以通过测量电流来估算氯离子的含量。

3. 操作步骤3.1 样品准备:将待测样品取适量加入测定仪的测量槽中,确保样品覆盖电极。

3.2 仪器设置:根据仪器操作手册设置相关参数,如测量时间、电流范围等。

3.3 测量记录:启动仪器并开始测量,待测量完成后记录电流数值。

3.4 数据处理:将记录的电流数值转换为氯离子浓度,根据仪器的相关算法或标准曲线进行计算。

4. 优点和局限性4.1 优点4.1.1 快速测量:相比传统的氯离子分析方法,使用氯离子含量快速测定仪可以在短时间内完成测量,提高分析效率。

4.1.2 简便操作:仪器的操作步骤相对简单,不需要繁琐的前处理步骤,减少了操作的难度。

4.1.3 高灵敏度:氯离子含量快速测定仪具有较高的灵敏度,可以检测到低至微克级别的氯离子含量。

4.2 局限性4.2.1 样品适用性:由于氯离子含量快速测定仪的原理限制,部分样品中可能存在其他离子干扰,需要进行前处理步骤以排除干扰。

4.2.2 仪器成本:氯离子含量快速测定仪是一种相对较为昂贵的分析设备,可能对部分实验室或企业的经济条件造成压力。

5. 结论使用氯离子含量快速测定仪可以快速、准确地测量样品中的氯离子含量,具有操作简便、灵敏度高等优点。

然而,需要注意的是样品适用性和设备成本等局限性。

在选择使用该仪器时,应根据具体需求综合考虑上述因素。

测定氯离子含量的标准

测定氯离子含量的标准

测定氯离子含量的标准测定氯离子含量是化学分析实验中常见的一项工作,其结果对于环境监测、食品安全、药品生产等领域都具有重要的意义。

本文将介绍测定氯离子含量的标准方法,以供参考。

首先,测定氯离子含量的标准方法主要包括两种,滴定法和电化学法。

滴定法是通过滴定试剂与待测溶液中的氯离子发生化学反应,从而确定氯离子含量的方法。

电化学法则是利用电化学原理,通过测定氯离子在电极上的电化学行为来确定其含量。

在进行滴定法测定氯离子含量时,首先需要准备标准溶液和指示剂。

然后将待测溶液与滴定试剂逐滴加入,直至出现终点反应,记录所耗滴定试剂的体积,通过计算可以得出氯离子含量。

而电化学法则需要使用离子选择电极和参比电极,通过电位差来确定氯离子的含量。

除了上述两种常见的方法外,还有其他一些测定氯离子含量的标准方法,如离子色谱法、荧光法等。

这些方法各有特点,可以根据实际需要选择合适的方法进行测定。

在进行氯离子含量测定时,需要注意一些实验操作的细节。

比如,在滴定法中,滴定试剂的浓度和标准溶液的配制要求都非常严格,否则会影响测定结果的准确性。

在电化学法中,电极的选择和校准也是至关重要的步骤。

此外,实验中还需要注意样品的处理和准备,避免样品中含有干扰物质,影响测定结果的准确性。

同时,实验过程中的环境条件也需要控制,如温度、湿度等因素都可能对测定结果产生影响。

总的来说,测定氯离子含量的标准方法有多种,选择合适的方法需要根据实际情况进行判断。

在进行测定时,需要严格按照标准操作流程进行,确保实验结果的准确性和可靠性。

希望本文介绍的内容能够对相关工作者有所帮助。

洛阳市区典型水体中氯离子含量调查

洛阳市区典型水体中氯离子含量调查

洛阳市区典型水体中氯离子含量调查曾来源;刘子旬;杨岚;程燊昱;耿梦珂;蔡建川;魏学锋【摘要】The adaptability of the standard addition method,the standard curve method and the silver nitrate titration method for the determination of water samples were compared. The standard addition method was selected and applied to measure the chloride ion concentration in samples due to its simple operation,rapid determination and good repeatability. The experimental results showed that the chloride ion concentration of tap water, reuse water, groundwater and surface water samples was 24.01~42.97 mg/L, 22.37 ~47.55 mg/L, 52.97 ~59.49 mg/L and 12.07 ~52.97 mg/L, respectively. Overall, the chloride ion contents in all the collected water samples in Luoyang were lower than the environmental quality standards,which reflected the relatively good quality of water to a certain extent.%比较了标准加入法、标准曲线法和硝酸银滴定法对水样测定的适应性,结果表明标准加入法操作简单,测定速度快和重现性好;采用标准加入法对水中氯离子含量进行测定,结果表明,所采集水样中自来水、回用中水、地下水、地表水中氯离子浓度范围分别为24.01~42.97 mg/L、22.37~47.55 mg/L、52.97~59.49mg/L和12.07~52.97 mg/L.整体来看,所采集水样中氯离子含量未超标,一定程度反映出洛阳市水体水质良好.【期刊名称】《广州化工》【年(卷),期】2018(046)004【总页数】3页(P110-112)【关键词】氯离子;离子选择电极;标准加入法【作者】曾来源;刘子旬;杨岚;程燊昱;耿梦珂;蔡建川;魏学锋【作者单位】河南科技大学化工与制药学院,河南洛阳 471003;河南科技大学化工与制药学院,河南洛阳 471003;河南科技大学化工与制药学院,河南洛阳 471003;河南科技大学化工与制药学院,河南洛阳 471003;河南科技大学化工与制药学院,河南洛阳 471003;河南科技大学化工与制药学院,河南洛阳 471003;河南科技大学化工与制药学院,河南洛阳 471003【正文语种】中文【中图分类】X131.2氯离子是水质监测的重要指标,《生活饮用水卫生标准》(GB5749-2006)[1]严格规定了不同水质氯离子的含量。

氯离子测定方法小结

氯离子测定方法小结

氯离子测定方法小结
氯离子是水中最丰富的元素,其在水中占有大量比例,可以有效地抑制水中腐败农作物和水库中有害生物的繁殖,以保证水库中水质正常,保持水面可供饮用和灌溉,因此有必要对水库中的氯离子浓度进行不定时的检测。

氯离子的测定有多种方法。

常用的指示剂法是采用循环伏安法进行检测。

由于氯离子在水中较易被电荷捕获,可用高平衡电位的指示剂试剂结合,由于其被结合的氯离子的大小,还有各种不同形式的加离子作用,从而在一定电荷下改变指示剂试剂的电位,指示剂试剂可以用来检测水中氯离子含量。

同时还有其他检测氯离子的方法,例如气相色谱法、原子吸收法等,这种方法所检测出来的结果与指示剂检测所检测出来的结果非常相近,因此,可以采用其他检测方法来检测和确定氯离子的含量。

总之,氯离子是影响水体水质的指标之一。

要准确测定水体中的氯离子,不仅要采用比较先进的实验装置,而且要掌握正确的实验步骤,避免误差,以确保检测结果的准确性和可靠性。

结晶器水氯离子含量标准_概述说明以及解释

结晶器水氯离子含量标准_概述说明以及解释

结晶器水氯离子含量标准概述说明以及解释1. 引言1.1 概述结晶器水氯离子含量标准是指用于衡量结晶器中水中氯离子的浓度的一项指标。

在许多工业和科研领域,结晶器经常被用于生产、实验和制造过程中。

不正确的水氯离子含量可能会对产品质量产生负面影响,因此确立一套准确可行的含量标准非常重要。

1.2 文章结构本文章分为五个主要部分:引言、正文、研究结果与讨论、实验方法和结果分析以及结论与展望。

其中,引言部分将介绍本文的研究对象——结晶器水氯离子含量标准,并说明该内容的概述、目的以及文章结构。

1.3 目的本文旨在系统概述和解释结晶器水氯离子含量标准,深入探讨其定义、重要性以及测量方法。

同时,还将针对现有标准进行调研与分析,并提出对该标准的改进建议。

通过扩展已有知识,为相关领域的工作者提供一个全面了解和应用这一标准的基础。

以上是“1. 引言”部分的清晰撰写内容,如有需要可以进一步修改和完善。

2. 正文:2.1 结晶器水氯离子含量的定义与重要性结晶器水氯离子含量是指结晶器中所含的氯离子的浓度。

在结晶过程中,水中的氯离子会影响晶体的生长和品质。

因此,准确地确定结晶器水氯离子含量对于保证晶体质量、提高生产效率以及延长设备寿命具有重要意义。

2.2 结晶器水氯离子含量的测量方法通常使用离子色谱法来测量结晶器中水样液中的氯离子含量。

该方法通过将待测样品经过适当处理后,在离子色谱仪中进行分析,然后根据峰面积或峰高来计算出溶液中的氯离子浓度。

采用此方法可以实现快速、准确和可靠地测定结晶器中水样液体中氯离子的含量。

2.3 结晶器水氯离子含量标准的制定与调整制定和调整结晶器水氯离子含量标准一般需要综合考虑多种因素。

首先,需要考虑到晶体产品质量要求以及生产工艺特点。

通过与相关标准和规范进行对比分析,并结合实际情况,可以确定适用于结晶器水氯离子含量的标准范围。

此外,还需要考虑到不同结晶器使用环境的差异以及监测和控制技术的可行性。

3. 研究结果与讨论:3.1 结晶器水氯离子含量标准的现状分析通过调查和研究现有的相关文献和规范,可以了解到目前关于结晶器水氯离子含量标准在不同行业和领域存在一定差异。

录井现场钻井液氯离子检定方法探讨

录井现场钻井液氯离子检定方法探讨

录井现场钻井液氯离子检定方法探讨摘要:录井参数在监测钻井液性能、分析钻井工程状况、预防工程事故、发现油气层以及解释评价工作中发挥着重要作用。

钻井液中氯离子能够提供多种信息,对于目前的钻井液氯离子检测方法进行了分析,对比摩尔法、离子色谱法、离子电极法不同适用条件和优缺点,以便选择合适的分析方法,提高氯离子检测精度及时效性,发挥录井参数在钻井工程监测中的作用。

关键词:录井现场;钻井液;氯离子监测方法1 前言随着录井技术的发展,录井现场参数越来越丰富,这些参数在监测钻井工程状况、预防工程事故、发现油气层以及解释评价工作中发挥着重要作用。

钻井液中氯离子检测是监测钻井液性能的重要指标。

钻井液中氯离子浓度参数作用表现在以下几个方面:首先,在钻遇地层水的情况下,钻井液中氯离子的含量明显升高,因此通过测量钻井液中氯离子变化情况即可了解地层出水情况,地层大量出水容易导致水侵,氯离子参数上也能直观反映出来。

通过监测氯离子浓度数据的变化是发现水浸,是解释油水层的一个重要途径;其次,检测氯离子浓度能够监测钻井液性能,以便合理调整药品;再次,钻遇膏盐岩地层后,钻井液中氯离子质量浓度明显增加。

因此可以通过这一特征来帮助现场识别膏盐岩地层,及时提示钻井工程人员,减少卡钻、井漏等复杂情况的发生,从而达到准确预报膏盐岩地层并安全钻进的目的[2-3]。

因此,加强对录井现场氯离子检测方法研究,提高氯离子检测精度及时效性,对于监测钻井液性能、及时发现钻井工程异常情况具有重要意义。

2 钻井液中氯离子检测方法探讨目前,溶液中氯离子浓度实验室分析方法较多,有摩尔法、共沉淀富集分光光度法、汞盐滴定法、离子色谱法及电位滴定法等。

钻井现场使用摩尔法测量氯离子,在实验室常用离子电极法和离子色谱法检测氯离子浓度。

2.1摩尔法钻井现场的氯离子检测方法一般是摩尔法(即硝酸银滴定法),该方法需要人工采样,化学滴定,测定原理是使用铬酸钾做指示剂,用硝酸银溶液与钻井液滤液中氯离子反应,首先生成氯化银沉淀,当水中的氯离子与硝酸银完全反应后,多余的硝酸银则与铬酸钾进行反应,从而生成较难溶于水的红色铬酸银,表明氯离子已经完全沉淀。

氯离子检测方法

氯离子检测方法

氯离子测定方法小结1、摩尔法测定范围适用于天然石、循环冷却水、以软化水为补给水的锅炉炉水中氯离子含量的测定测定范围为5mg/L~150mg/L。

测定原理以铬酸钾为指示剂在pH为5~9.5的范围内用硝酸银标准滴定溶液滴定。

硝酸银与氯化物作用生成白色氯化银沉淀当有过量硝酸银存在时则与铬酸钾指示剂反应生成砖红色铬酸银表示反应达到终点。

方法来源GB/T15453-2008工业循环冷却水和锅炉用水中氯离子的测定摩尔法注意事项测定终点因人而异误差较大。

2、电位滴定法测定范围适用于天然石、循环冷却水、以软化水为补给水的锅炉炉水中氯离子含量的测定测定范围为5mg/L~150mg/L。

测定原理以双液型饱和甘汞电极为参比电极以银电极为指示电极用硝酸银标准滴定溶液滴定至出现电位突跃点即理论终点即可从消耗的硝酸银标准滴定溶液的体积算出氯离子含量。

方法来源GB/T15453-2008工业循环冷却水和锅炉用水中氯离子的测定电位滴定法注意事项需要额外配备电磁搅拌器、电位滴定计、双液型饱和甘汞电极、银电极。

溴、碘、硫等离子存在干扰。

3、共沉淀富集分光光度法测定范围适用于除盐水、锅炉给水中氯离子含量的测定测定范围为10μg/L~100μg/L。

测定原理基于磷酸铅沉淀做载体共沉淀富集痕量氯化物经高速离心机分离后以硝酸铁-高氯酸溶液完全溶解沉淀加硫氰酸汞-甲醇溶液显色用分光光度法间接测定水中痕量氯化物。

方法来源GB/T15453-2008工业循环冷却水和锅炉用水中氯离子的测定共沉淀富集分光光度法注意事项需要额外配备分光光度计460nm波长、30mm吸收池、高速离心机转速5000r/min配有250mL聚乙烯离心管。

4、汞盐滴定法测定范围适用于天然水、锅炉水、冷却水中氯离子含量的测定测定范围为1mg/L~100mg/L超过100mg/L时可适当地减少取样体积稀释至100mL后测定。

测定原理在pH2.3~2.8的水溶液中氯离子与汞离子反应生成微解离的氯化汞。

氯离子测试方法

氯离子测试方法

附件五氯离子(Cl-)浓度的测定方法
附件十二脱水石膏中氯离子(Cl-)质量百分比的测定方法
附注:
K2CrO4(5%)溶液配制
溶解5克K2CrO4于100ml水中,在搅拌下滴加AgNO3标准溶液至砖红色沉淀生成,过滤溶液.
AgNO3标准溶液(0.1 mol·L-1)配制
称取16.9克AgNO3溶解于水中,稀释至1升,摇匀,储于棕色试剂瓶中。

标定AgNO3标准溶液
吸取25ml 0.1000 mol·L—1 NaCl标准溶液于250ml锥形瓶中,用水稀释至50ml,加1ml 5% K2CrO4溶液,在不断摇动下用AgNO3标准溶液滴定,直至溶液由黄色变为稳定的桔红色,即为终点。

同时作空白实验
AgNO3标准溶液的浓度可按下式计算:
式中:—AgNO3标准溶液的浓度;
V—滴定用去AgNO3标准溶液的总体积;
CNaCl——NaCl标准溶液的浓度;
V1——NaCl标准溶液的体积;
V0——空白滴定用去的AgNO3标准溶液的总体积;
户县浆液Cl离子计算
用去0.09915l/L硝酸银20。

9ml 计算得Cl离子浓度为14693mg/L 即14693ppm
户县石膏中Cl离子浓度
用去0。

09915/ L硝酸银4.8ml 计算得Cl离子浓度为337mg/L 即337ppm。

氯离子含量测定方法的适用性探

氯离子含量测定方法的适用性探

氯离子含量测定方法的适用性探讨0 前言氯离子含量是电厂水汽的一个重要控制指标。

电厂水汽系统中的水质种类较多,如:中水、循环冷却水、原水(井水、水库水、自来水、河水等)、反渗透出水、炉水、凝结水、除盐水、给水及各种蒸汽等。

这些水中氯离子的测定,国家标准及电力行业标准规定了许多测试方法,如:摩尔法、电位滴定法、汞盐滴定法、PCl 电极法、共沉淀富集分光光度法、离子色谱法等等。

每种方法都规定了适用范围,即不同的水质,氯离子含量不同,则适用的测定方法不同。

但从现场应用来看,到目前为止仍然存在方法混淆的问题,严重影响了测定的精度。

本文介绍了摩尔法测定氯离子含量时产生的误差及计算方法,指出了微量氯离子分析操作中应注意的事项,提供了炉水中氯离子的测定方法。

1 摩尔法测定氯离子时产生的误差对于电厂原水中氯离子含量分析,“摩尔法”得到广泛采用。

该方法测定氯离子的范围为5~100mg/L;下面利用沉淀溶解平衡原理对水样中余留的氯离子含量进行计算。

1.1 方法原理水样以铬酸钾作指试剂,在中性或弱碱性条件下,用硝酸银标准溶液进行滴定,出现砖红色铬酸银沉淀时指示终点到达。

反应如下:1.2 水样滴定过程取一定量的水样于250mL 锥形瓶中,添加除盐水至100mL,在锥形瓶中加入1mL 10% K2CrO4 指示剂,用AgNO3 标准溶液滴定。

此时CrO42- 的浓度为由于AgCl 的溶解度(1.3*10-5mol/L)小于Ag2CrO4 的溶解度(6.5*10-5mol/L),根据分步沉淀原理,在滴定过程中,AgCl 首先沉淀出来。

随着AgNO3 标准溶液的加入,AgCl 沉淀不断生成,溶液中氯离子浓度越来越小,Ag+ 浓度相应地越来越大,直至与CrO42-浓度的乘积超过Ag2CrO4 的溶度积时,便出现砖红色Ag2CrO4 沉淀,以此指示滴定的终点。

1.3 误差计算滴定达到终点时,溶液中有两种沉淀AgCl 和Ag2CrO4 均已饱和,此时与这两种沉淀相接触的溶液中Cl-、CrO42- 和Ag+浓度应当同时满足式(3)、(4)又因为两种沉淀在同一溶液中,所以两式中[Ag+] 应相等则:又因为[CrO42-] = 5.15*10-3mol/L,所以以计算结果表明,滴定达到终点时,Cl- + Ag+→ AgCl ↓ ,由于沉淀溶解平衡的存在,溶液中仍然有0.44mg/L 的氯离子。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

75 各种氯离子含量 测定方法的适用性探讨及新方法的提出周少玲,张 永山东电力研究院,山东济南 250002[摘 要] 介绍了摩尔法测定氯离子含量时产生的误差及计算方法,明确了不同氯离子含量测定方法的适用性,并提供了硫氰酸汞分光光度法测定电厂炉水中氯离子含量的新方法。

[关 键 词] 电厂;水汽系统;氯离子测定方法;硫氰酸汞分光光度法[中图分类号] O655[文献标识码] A[文章编号] 100223364(2008)0720075203作者简介: 周少玲(19642),女,1986年毕业于山东大学化学系,现为山东电力研究院高级工程师,从事电厂化学分析及其研究。

E 2mail :zhoushaolingsd @ 氯离子含量是电厂水汽控制的1项重要指标。

电厂水汽系统中的水质种类较多,如:循环冷却水、原水(包括井水、水库水、自来水、河水、中水等)、反渗透出水、炉水、凝结水、除盐水、给水及各种蒸汽等。

对于这些水中氯离子的测定,国家标准及电力行业标准规定了许多测试方法,如:摩尔法、电位滴定法、汞盐滴定法、PCl 电极法、共沉淀富集分光光度法、离子色谱法等等。

每种方法都规定了适用范围,即不同的水质氯离子含量不同,则适用的测定方法不同。

然而,现场应用存在方法混用的现象,严重影响了测定的精度。

本文介绍了摩尔法测定氯离子含量时产生的误差及计算方法,指出了微量氯离子分析操作中应注意的事项,并提供了炉水中氯离子的测定方法。

1 摩尔法测定氯离子时产生的误差对于电厂原水中氯离子含量的分析,摩尔法得到广泛采用。

该方法测定氯离子的范围为(5~100)mg/L 。

1.1 方法原理水样以铬酸钾为指试剂,在中性或弱碱性条件下,用硝酸银标准溶液进行滴定,出现砖红色铬酸银沉淀时到达指示终点。

反应如下:Cl -+Ag +AgCl ↓ (白色)(1)CrO 2-4+2Ag +Ag 2CrO 4↓ (砖红)(2)1.2 水样滴定过程取一定量的水样于250mL 锥形瓶中,添加除盐水至100mL ,在锥形瓶中加入1mL 10%K 2CrO 4指示剂,用AgNO 3标准溶液滴定。

此时,CrO 2-4的浓度为:C CrO 2-4=1×10%194.19×100×1000=5.15×10-3mol/L 。

由于AgCl 的溶解度(1.3×10-5mol/L )小于Ag 2CrO 4的溶解度(6.5×10-5mol/L ),根据分步沉淀原理,在滴定过程中,AgCl 首先沉淀出来。

随着Ag 2NO 3标准溶液的加入,AgCl 沉淀不断生成,溶液中氯离子浓度越来越小,Ag +浓度相应地越来越大,直至与CrO 2-4浓度的乘积超过Ag 2CrO 4的溶度积时,便出现砖红色Ag 2CrO 4沉淀,达到滴定的终点。

1.3 误差计算滴定达到终点时,溶液中有两种沉淀,即AgCl 和Ag2CrO4的沉淀,它们均已饱和。

此时,与这两种沉淀物质相接触的溶液中Cl-、CrO2-4和Ag+浓度应当同时满足式(3)和式(4)。

[Ag+][Cl-]=K SP AgCl=1.8×10-10(3) [Ag+]2[CrO2-4]=K SP Ag2CrO4=1.1×10-12(4)因为上述两种沉淀物质在同一溶液中,所以式(3)和式(4)中[Ag+]应相等,则:Cl-CrO2-4=K SP AgClK SP Ag2CrO4=1.8×10-101.1×10-12。

又,因为[CrO2-4]=5.15×10-3mol/L,所以Cl-=1.8×10-10× 5.15×10-31.1×10-12=1.23×10-5mol/L=0.44mg/L。

以上计算结果表明,滴定达到终点时,由于沉淀溶解平衡的存在,溶液中仍然有0.44mg/L的氯离子。

即:由于AgCl的沉淀溶解损失,溶液中仍然余留0.44 mg/L的氯离子不能被滴定。

所以,对于氯离子含量低的水质如炉水、凝结水等,用摩尔法测定氯离子会造成较大的分析误差。

稀释AgNO3浓度只能使消耗的AgNO3体积相对增加,减少了滴定管读数误差,而由沉淀溶解损失造成的误差是不可避免的。

1.4 NH+4对摩尔法测定中水中氯离子的影响在中水的水质全分析过程中,应用摩尔法测定中水的氯离子含量时,中水中N H+4含量不可忽视,有些中水的N H+4含量每升高达数十毫克。

若此时溶液的p H值较高,溶液中会有氨存在。

这样,在用AgNO3滴定氯离子的过程中,Ag+易与溶液中的氨形成银氨络离子Ag(N H3)+,从而增加了AgNO3的消耗量,造成分析结果偏高。

所以,摩尔法测定中水中氯离子含量时,应控制溶液的p H值为中性。

2 炉水中氯离子的测定对于炉水中氯离子含量的测定,摩尔法、PCl电极法在一定程度上灵敏度不够高,不能满足微量氯离子的测定要求。

共沉淀富集分光光度法的测定范围为(10~100)μg/L,而许多电厂的炉水中氯离子含量大于此范围,并且试验中采用沉淀浓缩富集,作为现场检测手段多有不便。

其它测定氯离子含量的方法如离子色谱法、原子吸收分光光度间接法,虽然能检测微量级氯离子,但所用仪器价格昂贵,环境要求严格,难以作为现场检测手段。

为了满足现场要求,下文将提供硫氰酸汞分光光度法,用于测定电厂炉水中的氯离子含量。

(1)方法概要 在含氯离子的溶液中,氯离子与硫氰酸汞发生反应,生成氯化汞并释放出SCN-;在高氯酸介质中,Fe3+与SCN-形成稳定的橘红色络合物,此络合物的呈色强度与氯离子的含量成线性关系,且460nm为最大吸收波长。

将吸光度与浓度进行曲线拟合,经回归计算,即可得回归方程。

(2)仪器及试剂 仪器为7212100分光光度计, 100mm比色皿,50mL容量瓶,100mL锥形瓶;试剂为高纯水、硝酸铁2高氯酸溶液、硫氰酸汞2甲醇溶液、氯离子标准溶液。

(3)标准工作曲线 取1组氯离子标准溶液,用移液管分别加入5.0mL高氯酸2硝酸铁溶液,摇匀,再加入2.0mL0.2%硫氰酸汞2甲醇溶液,摇匀,放置5 min。

用7212100分光光度计,波长为460nm,比色皿为100mm,以高纯水作参比,测量吸光度。

根据测得吸光度和相应的氯离子含量,计算回归方程。

(4)水样的测定 取50mL炉水水样,转移到100 mL锥形瓶中(水样应澄清,否则过滤),按上述绘制工作曲线的步骤加试剂发色,测定吸光度。

从回归方程中计算出氯离子含量。

上述方法简单、灵敏、适合现场应用,应用7212100分光光度计就可检测炉水中微量氯离子。

该方法测定范围为(0.018~6.0)mg/L,回收率范围为98.3%~113.0%。

此方法已在山东省一些电厂推广应用,对及时检测炉水中氯离子含量以及控制炉水品质起到了较好的作用。

3 微量氯离子测定当氯离子含量在每升数微克级或以下时,如电厂蒸汽、给水、除盐水、凝结水等,可用共沉淀富集分光光度法、离子色谱法等对氯离子进行测试。

检测过程中要注意所用药品纯度、空白水的纯度、避免水样污染等问题。

4 结 语综上所述,在测定水样的氯离子含量时,首先应明确测定方法的测量范围及适用性,并要注意每一种方法的测定条件及干扰离子的影响,以保证测定数据的准确性。

76 [参 考 文 献][1] 宋天佑,程鹏,王杏乔.无机化学(上册)[M].高等教育出版社,2004.[2] 日本分析化学会北海道分会.水的分析[M].孙铁珩,陈铨荣,刘国光,等译.北京:中国建筑工业出版社,1979.AN APPR OACH T O SUIT ABI LIT Y OF V ARIOU S METH ODS FOR DETECTING CONTENT OF CH LORIONS AN D PROPOSAL OF A NEW METH ODZHOU Shao2ling,ZHAN G Y ongShandong Electric Power Research Instit ute,Jinan250002,Shandong Province,PRCAbstract:The error produced in detection of chlorion’s content by using molar method has been presented,the suitability of different methods in detecting the content of chlorions being clarified,and a new method for detecting chlorions’content in boiler water of ther2 mal power plants by using spectrophotometric method of mercury sulfocyanide being put forward.K ey w ords:power plant;water2steam system;chlorion detecting method;spectrophotometric method of mercury sulfocyanide(上接第74页)3.3.3 需要避免的错误在BSP开发过程中应注意:(1)ROM和RAM的基地址不能等于0。

(2)避免在BSP中使用printf()。

(3)避免使用malloc()等缓冲区调用函数。

(4)若BSP中有“//”等C编译器不能识别的注释,则需在编译生成映像文件的过程中在C/C++编译器中去掉2ansi。

(5)避免在同一网段内与其它网络设备的IP和MAC地址重复。

4 结 语本文中介绍的BSP开发方法适用于目前大部分嵌入式处理器。

在开发出DCS控制器的底层软件后,可以继续编写DCS控制器的上层应用软件,为其执行简单的或复杂的控制策略提供功能强大的控制手段。

控制器与DCS各种卡件组合使用,可实现火电厂的控制。

[参 考 文 献][1] 周启平,张杨.VxWorks下设备驱动程序及BSP开发指南[M].北京:中国电力出版社,2004.[2] 王金刚.VxWorks BSP开发人员指南[M].北京:清华大学出版社,2003.[3] 岳晓东,蔡本华,贺占庄.基于实时嵌入式系统的BSP构建技术[J].微电子学与计算机,2006(5).[4] Wind River.VxWorks Bsp Developers Guide5.5[Z].2003.[5] Wind River.VxWorks For Arm Architecture Supplement5.5[Z].2003.DEVE LOPMENT OF BOTTOM LAYER SOFTWARE FOR DCS CONTROLL ERIN POWER PLANTS BASED ON INSERT TYPE CPUZHAN G Bo2wei,YAN Yu2ping,XU E Jian2zhong,J IN G Xiao2guo,YE Zhi,CU I Y in2qun,ZHAN G XiangXi’an Thermal Power Research Instit ute Co Lt d,Xi’an710032,Shaanxi Province,PRCAbstract:On the basis of making a comparison with controllers of various DCS controllers,an ARM9controller based on the VxWorks operating system has been developed,and depending on the development platform in laboratory,the developed controller being tested.The principle and method for designing and realizing the said controller have also been presented.K ey w ords:thermal power plant;DCS;ARM9controller;VxWorks operating system;board support package;image77。