离心距离传感器产品说明说明书
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
1
Proximity Sensors Inductive Stainless Steel Housing
Types IA, M12, M18 and M30, NAMUR
•Stainless steel housing, cylindrical •Diameter: M12, M18, M30•Short or long versions
•Sensing distance: 2 to 15 mm •Output: NAMUR EN 50 227•Protection: Reverse polarity •LED-indication
•2 m cable or plug M12
Product Description
60 947-5-2. F or thermoplastic housing refer to type IA 12C....Amplifier relay SD.... is avail-able.
Proximity switch in M12, M18and M30 stainless steel hous-ing. Made in accordance with Euronorm EN 50 227 and EN
Type Selection
Housing Body Connection Rated operating Ordering no.diameter style distance (S n )Namur
M12Short Cable 2 mm 1)IA 12 ESF 02 UC M12Short Plug 2 mm 1)IA 12 ESF 02 UC M1M12Long Cable 2 mm 1)IA 12 ELF 02 UC M12Long Plug 2 mm 1)IA 12 ELF 02 UC M1M12Short Cable 4mm 2)IA 12 ESN 04 UC M12Short Plug 4 mm 2)IA 12 ESN 04 UC M1M12Long Cable 4 mm 2)IA 12 ELN 04 UC M12Long Plug 4 mm 2)IA 12 ELN 04 UC M1M18Short Cable 5 mm 1)IA 18 ESF 05 UC M18Short Plug 5 mm 1)IA 18 ESF 05 UC M1M18Long Cable 5mm 1)IA 18 ELF 05 UC M18Long Plug 5 mm 1)IA 18 ELF 05 UC M1M18Short Cable 8 mm 2)IA 18 ESN 08 UC M18Short Plug 8 mm 2)IA 18 ESN 08 UC M1M18Long Cable 8 mm 2)IA 18 ELN 08 UC M18Long Plug 8 mm 2)IA 18 ELN 08 UC M1M30Short Cable 10 mm 1)IA 30 ESF 10 UC M30Short Plug 10 mm 1)IA 30 ESF 10 UC M1M30Long Cable 10 mm 1)IA 30 ELF 10 UC M30Long Plug 10 mm 1)IA 30 ELF 10 UC M1M30Short Cable 15 mm 2)IA 30 ESN 15 UC M30Short Plug 15 mm 2)IA 30 ESN 15 UC M1M30Long Cable 15 mm 2)IA 30 ELN 15 UC M30
Long
Plug
15 mm 2)
IA 30 ELN 15 UC M1
1)For flush mounting in metal
2)
For non-flush mounting in metal
2
IA 12, IA 18, IA 30, NAMUR
Specifications
Dimensions
Type
A B C D E F SW Ømm mm mm mm mm mm IA 12 ESF 02 UC M12 x 1 x 3010.73011 5.0417IA 12 ELF 02 UC M12 x 1 x 5010.75011 5.0417IA 12 ESF 02 UC M1M12 x 1 x 3010.73012.611.9417IA 12 ELF 02 UC M1M12 x 1 x 5010.75012.611.9417IA 12 ESN 04 UC M12 x 1 x 3010.73411 5.0417IA 12 ELN 04 UC M12 x 1 x 5010.75411 5.0417IA 12 ESN 04 UC M1M12 x 1 x 3010.73412.611.9417IA 12 ELN 04 UC M1M12 x 1 x 5010.75412.611.9417IA 18 ESF 05 UC M18 x 1 x 3016.73011.615.4424IA 18 ELF 05 UC M18 x 1 x 5016.75011.615.4424IA 18 ESF 05 UC M1M18 x 1 x 3016.73013.111.9424IA 18 ELF 05 UC M1M18 x 1 x 5016.75013.111.9424IA 18 ESN 08 UC M18 x 1 x 3016.73811.615.4424IA 18 ELN 08 UC M18 x 1 x 5016.75811.615.4424IA 18 ESN 08 UC M1M18 x 1 x 3016.73813.111.9424IA 18 ELN 08 UC M1M18 x 1 x 5016.75813.111.9424IA 30 ESF 10 UC M30 x 1.5 x 30283013.615.4536IA 30 ELF 10 UC M30 x 1.5 x 50285013.615.4536IA 30 ESF 10 UC M1M30 x 1.5 x 30283013.611.9536IA 30 ELF 10 UC M1M30 x 1.5 x 50285013.611.9536IA 30 ESN 15 UC M30 x 1.5 x 30284213.615.4536IA 30 ELN 15 UC M30 x 1.5 x 50286213.615.4536IA 30 ESN 15 UC M1M30 x 1.5 x 30284213.611.9536IA 30 ELN 15 UC M1
M30 x 1.5 x 50
28
62
13.6
11.9
5
36
3
Power Supplies
>SD 110/210>SD 170/270
Refer to T echnical information.
IA 12, IA 18, IA 30, NAMUR
Dimensions (cont.)
Wiring Diagram
+
-
BN
R BU
1K
8.2 V
Installation Hints
Incorrect
Correct
The cable should not be pulled
A proximity switch should not serve as mechanical stop
Any repetitive flexing of the cable should be avoided。