《铁路旅客车站建筑设计规范》2007
《铁路旅客车站建筑设计规范》
1 总则1、0、1 为统一铁路旅客车站建筑设计标准,使铁路旅客车站建筑设计符合“功能性、系统性、先进性、文化性、经济性”得要求,制定本规范.1、0、2本规范适用于新建铁路旅客车站建筑设计。
1、0、3 旅客车站布局应符合城镇发展与铁路运输要求,并根据当地经济、交通发展条件,合理确定建筑形式.1、0、4铁路旅客车站建筑设计应积极采用安全、节能与符合环境保护要求得先进技术。
1、0、5客货共线与客运专线铁路旅客车站得建筑规模,应分别根据最高聚集人数与高峰小时发送量按表1、0、5—1与表1、0、5—2确定。
表1、0、5-1 客货共线铁路旅客车站建筑规模表1、0、5-2客运专线铁路旅客车站建筑规模1、0、6铁路旅客车站无障碍设计应符合现行《铁路旅客车站无障碍设计规范》(TB10083)与《城市道路与建筑物无障碍设计规范》JGJ50得有关规定。
1、0、7 铁路旅客建筑节能设计应符合现行国家标准《公共建筑节能设计标准》GB50189 得有关规定。
1、0、8铁路旅客车站建筑设计除应符合本规范外,尚应符合国家现行有关强制性标准得规定.2 术语2、0、1铁路旅客车站railway passenger station为旅客办理客运业务,设有旅客乘降设施,并由车站广场、站房、站场客运建筑三部分组成整体得车站.2、0、2客货共线铁路旅客车站 mixed traffic railway linestation设在客货共线运行得铁路沿线,主要办理客运业务得车站。
2、0、3客运专线铁路旅客车站 passenger dedicated railway line station设在客运专线铁路沿线,专门办理客运业务得车站.2、0、4 旅客最高聚集人数m aximum passengersin waiting room旅客车站全年上车旅客最多月份中,一昼夜在候车室内瞬时(8~10min)出现得最大候车(含送客)人数得平均值。
2、0、5高峰小时发送量peak hour departing quan tum车站全年上车旅客最多月份中,日均高峰小时旅客发送量. 2、0、6站房平台platform for station buildin g由站房外墙向城市方向延伸一定宽度,连接站房各个部位及进出口得平台。
国家铁路局发布《铁路旅客车站设计规范》局部修订公告
国家铁路局发布《铁路旅客车站设计规范》局部修订公告无
【期刊名称】《铁道技术标准(中英文)》
【年(卷),期】2023(5)1
【摘要】为满足铁路旅客车站运营管理和综合服务需求,提升人民群众出行品质,推动铁路旅客车站设计建造技术进步,拟对《铁路旅客车站设计规范》TB 10100-2018相关内容进行局部修订。
自2022年10月14日起实施。
一、修改第3.2.2条内容铁路客站站房建筑面积应满足客流运输、旅客服务需求,根据铁路客站最高聚集人数,按下列指标计算确定.
【总页数】4页(P119-122)
【作者】无
【作者单位】国家铁路局规划与标准研究院技术标准所
【正文语种】中文
【中图分类】F53
【相关文献】
1.关于发布国家标准《铁路旅客车站建筑设计规范》局部修订的公告
2.国家铁路局发布《高速铁路设计规范》《城际铁路设计规范》信号条款局部修订
3.国家铁路局发布行业标准《铁路斜拉桥设计规范》国家铁路局发布《铁路斜拉桥设计规范》
4.国家铁路局发布行业标准《铁路桥梁钢管混凝土结构设计规范》国家铁路局发布《铁路桥梁钢管混凝土结构设计规范》
5.国家铁路局发布行业标准《市域(郊)铁路设计规范》国家铁路局发布《市域(郊)铁路设计规范》
因版权原因,仅展示原文概要,查看原文内容请购买。
铁路旅客车站站房建筑规模的合理确定与投资控制
铁路旅客车站站房建筑规模的合理确定与投资控制>摘要:随着我国国民经济不断发展,人民群众的生活水平不断提高,人们对基础设施的建设提出了更高的要求。
我国是一个人口大国,在铁路基础设施建设方面对人民群众基本成活要求尤其重要。
我国铁路旅客车站站房建设是保证我国铁路运输正常运作的重要部分。
我国政府在2008年对铁路网进行了最新的调整与规划,铁路旅客车站的建设取得了一定的成果。
各大城市均出现了造型美观,功能齐全的综合车站。
北京南、天津、广州南等300座左右的新型车站正式开始投入使用,另外还有贵阳北、杭州南等240座左右的新型车站正在建设中。
经过科学预测,到2015年,我国新建与扩建的新型车站将预期达到一千多座。
但是在建设新型车站的过程中同样存在一定的困难与问题,例如新型车站站房的建设规模的合理性是建设过程中需要解决的首要问题。
一、站房建设存在的主要问题(一)站房规模制定标准不一目前我国正在建设、完成建设以及改建的铁路都存在旅客站房规模调整的问题。
例如甬台温铁路线初步设计的宁海、温岭、乐清等车站站房给的面积为1850平方米左右。
但在当地政府的强烈意见下,部分旅客站房规模进行了一定的调整。
经过调整后的站房面积最小的为3500平方米,最大的站房面积为10000平方米[1]。
(二)站房规模计算方式不一目前我国铁路旅客车站发展迅速,综合型多功能车站数量逐渐增加。
站房设计单位在统计站房规模方面存在较大的差异。
例如针对桥式车站设计在对经济技术指标进行统计时,一般会设计到高架候车室下部空间等方面的计算,站房主体前后的挑檐是否应该计算等种种问题。
(三)站房投资增加对全线投资控制部分铁路旅客车站进行改建或扩大的初步设计批复比初步设计方案批复的投资数额增长较大。
例如甬台温沿线旅客车站进行初步修改后投资增加18.2亿元,在增加投资数额中其中有12亿元是由于站房规模调整所导致。
由此看来我国在建的或完成建设的各大铁路运行现楼项目投资增加的主要原因之一就是站房规模进行不一的调整。
高铁客运站最高聚集人数计算方法研究
高铁客运站最高聚集人数计算方法研究叶玉玲;李文卿【摘要】高铁客运站最高聚集人数是设计高铁客运站站房规模的主要依据之一,随着高速铁路的不断建设与发展,旅客的出行模式发生了较大变化,高速铁路客运站旅客聚集规律也随之改变.论文在分析现有铁路客运站最高聚集人数研究成果的基础上,对高速铁路客运站最高聚集人数的计算方法进行研究,改进和修正原有的概率计算方法,考虑到列车开行频率、检票人数等因素对高铁客运站聚集人数的影响,认为高速铁路旅客的候车时间分布规律符合对数正态分布,综合建立高速铁路客运站最高聚集人数预测模型,并通过案例计算进行验证.【期刊名称】《华东交通大学学报》【年(卷),期】2018(035)004【总页数】7页(P76-82)【关键词】高铁客运站;最高聚集人数;候车时间分布;旅客聚集规律【作者】叶玉玲;李文卿【作者单位】同济大学道路与交通工程教育部重点实验室,上海 201804;同济大学道路与交通工程教育部重点实验室,上海 201804【正文语种】中文【中图分类】U2391 引言1.1 研究背景预计到2020年,我国高速铁路里程达3万km,覆盖80%以上的大城市,到2025年,高速铁路规模达到3.8万km左右。
高速铁路的建设需要进行车站特别是站房面积和设施规模的计算。
根据《铁路旅客车站建筑设计规范(GB50226-2007)》,我国客运站旅客流线形式存在等候式、通过式、等候与通过混合式共三种模式,既有线车站属于等候式,站房规模的控制使用最高聚集人数,客运专线车站属于通过式,站房规模的控制使用高峰小时发送量这一指标。
随着高速铁路的发展,《高速铁路设计规范(TB10621-2014)》指出,最高聚集人数是客运站等候设施如候车区、盥洗间、旅客厕所等的计算依据,作为客运站规模设计的重要指标,高峰小时发送量和最高聚集人数分别考虑不同的衡量点,两者之间并不能相互取代或换算,而是应该结合使用、综合确定,高峰小时发送量决定安检设施、集散厅、通道、楼扶电梯、检票闸机等通过类设施,最高聚集人数确定候车区、盥洗间、旅客厕所等等候类设施。
建设部公告第665号--关于发布国家标准《铁路旅客车站建筑设计规范》的公告
建设部公告第665号--关于发布国家标准《铁路旅客车站建筑设计规范》的公告
文章属性
•【制定机关】建设部(已撤销)
•【公布日期】2007.06.22
•【文号】建设部公告第665号
•【施行日期】2007.12.01
•【效力等级】部门规范性文件
•【时效性】现行有效
•【主题分类】标准化
正文
建设部公告
(第665号)
现批准《铁路旅客车站建筑设计规范》为国家标准,编号为GB50226-2007,自2007年12月1日起实施。
其中,第4.0.8、4.0.11、5.2.4、5.2.5、5.7.1、5.8.8、5.9.2、6.1.1、6.1.3、6.1.4(3)、6.1.7(1)(3)(7)、6.4.5、7.1.1、7.1.2、7.1.4、7.1.5、7.1.6、8.3.2(5)、8.3.4条(款)为强制性条文,必须严格执行。
原《铁路旅客车站建筑设计规范》GB50226-95同时废止。
本规范由建设部标准定额研究所组织中国计划出版社出版发行。
中华人民共和国建设部
二○○七年六月二十二日。
铁路旅客车站建筑设计
铁路旅客车站建筑设计1 总则1.0.1为保证铁路旅客车站建筑设计符合安全、适用和卫生等基本要求,制订本规范。
1.0.2本规范适用于标准轨距国家铁路旅客车站新建、改建和扩建工程的建筑设计。
1.0.3铁路旅客车站站房(以下简称站房)除应按设计年度远期的客运量确定规模外,宜预留扩建的余地。
易扩建的站场客运建筑可分期建设。
1.0.4铁路旅客车站的建筑规模,应根据旅客最高聚集人数(以下简称最高聚集人数),按表1.0.4划分为四级。
铁路旅客车站建筑规模的划分表1.0.41.0.5铁路旅客车站建筑设计除应符合本规范外,尚应符合国家现行有关标准的规定。
2 术语2.0.1铁路旅客车站 Railway passenger station为旅客办理客运业务,设有旅客候车和安全乘降设施,并由站前广场、站房、站场客运建筑三者组成整体的车站。
2.0.2旅客最高聚集人数 Maximum passengers in waiting room旅客车站全年上车旅客最多月份中,一昼夜在候车室内瞬时(8~10min)出现的最大候车(含送客)人数的平均值。
2.0.3站房平台 Platform for station building由站房外墙向城市方向延伸一定宽度,连接站房各个部位及进出站口的平台。
2.0.4旅客车站专用场地 Special area for passenger station自站房平台外缘至相邻城市道路内缘和相邻建筑基地边缘范围内,包括旅客活动地带与人行通道、车行道、停车场、绿化、建筑小品使用的场地。
2.0.5公交站点 Bus stop设于站前广场内城市公共交通车辆的首末站或中途站。
2.0.6线侧下式站房 Low—lying station building旅客车站站场线路的高程高于站前广场地面高程,站房首层地面低于站台面,且高差较大,分层布置的站房。
2.0.7高架跨线候车室 Elevated overcrossing waiting room位于旅客站台与线路上方,且与站房相连,主要为候车使用的建筑物。
TB 10063-2007 铁路工程设计防火规范
目 次1 总 则 (1)2 火灾危险性分类和耐火等级 (2)3 防火间距..................................................................(3) 3.1 线 路..................................................................(3) 3.2 机务、车辆设施 (5)4 可燃液体和可燃气体管道穿越铁路.................................(7) 4.1 管道穿越线路.........................................................(7) 4.2 管道穿越桥涵.........................................................(8) 4.3 管道穿越站场 (8)5 消防车道 (9)站 场 (9)5.2 机车、车辆、动车段(所) (10)6 建筑防火分区和建筑构造 (12)旅客车站 (12)6.2 电气设备房屋 (12)6.3 厂房(仓库)......................................................(13) 6.4 其他 (15)7 消防给水和灭火设施 ................................................ (16) 7.1 室外消防给水 ......................................................(16) 7.2 室内消防给 .........................................................(19) 7.3 灭火设施 (19)w .b zf xw .c8 通风、空气调节及防烟与排烟 .................................... (22) 8.1 通风、空气调节................................................... (22) 8.2 防烟与排烟 .........................................................(22) 9 电气 ..................................................................... (24) 9.1 火灾自动报警 (24)9.2 电线电缆 ............................................................(25) 9.3 防雷 、防爆 (25)10 铁路隧道 ...............................................................(26) 附录A 主要生产房屋的火灾危险性分类 (29)附录B 主要生产场所爆炸和火灾危险等级分区 (30)附录C 防火间距的起算点............................................. (31) 附录D 灭火器配置的主要生产场所危险等级分类 (32)本规范用词说明 (33)《铁路工程设计防火规范》条文说明 (34)w .b zf xw .c1 总 则1.0.1 为保障铁路运输生产和人民生命财产安全,在铁路工程设计中贯彻“预防为主,防消结合”的消防工作方针,防止和减少火灾危害,制定本规范。
铁路旅客车站建筑设计站场客运建筑
铁路旅客车站建筑设计站场客运建筑6.1 站台、雨篷6.1.1 客货共线铁路车站站台的长度、宽度、高度应符合现行国家标准《铁路车站及枢纽设计规范》GB 50091的有关规定。
客运专线铁路车站站台的设置应符合国家及铁路主管部门的有关规定。
6.1.2 铁路站房或建筑物最外凸出部分外缘至基本站台边缘的距离,特大型站宜为20~25m;大型站宜为15~20m;中型站宜为8~12m;小型站宜为8m,困难条件下不应小于6m。
6.1.3 当旅客站台上设有天桥或地道出入口、房屋等建筑物时,其边缘至站台边缘的距离应符合下列规定:1 特大型和大型站不应小于3m。
2 中型和小型站不应小于2.5m。
3 改建车站受条件限制时,天桥或地道出入口其中一侧的距离不得小于2m。
4 当路段设计速度在120km/h及以上时,靠近有正线一侧的站台应按本条1~3款的数值加宽0.5m。
6.1.4 旅客站台设计应符合下列规定:1 站台应采用刚性防滑地面,并满足行李、包裹车荷载的要求,通行消防车的站台还应满足消防车荷载的要求。
2 站台地面应有排水措施。
3 旅客列车停靠的站台应在全长范围内,距站台边缘1m处的站台面上设置宽度为0.06m的黄色安全警戒线,安全警戒线可与提示盲道结合设计。
当有速度超过120km/h 的列车临近站台通过时,安全警戒线和防护设施应符合铁路主管部门的有关规定。
6.1.5 当中间站台上需要设置房屋时,宜集中设置。
6.1.6 客运专线铁路旅客车站应设置与站台同等长度的站台雨篷。
客货共线铁路的特大型、大型旅客车站应设置与站台同等长度的站台雨篷。
根据所在地的气候特点,中型及以下车站宜设置与站台同等长度的站台雨篷或在站台局部设置雨篷,其长度可为200~300m。
6.1.7 旅客站台雨篷设置应符合下列规定:1 雨篷各部分构件与轨道的间距应符合现行国家标准《标准轨距铁路建筑限界》GB 146.2的有关规定。
2 中间站台雨篷的宽度不应小于站台宽度。
《铁路旅客车站建筑设计规范》
1 总则为统一铁路旅客车站建筑设计标准,使铁路旅客车站建筑设计符合“功能性、系统性、先进性、文化性、经济性”的要求,制定本规范。
本规范适用于新建铁路旅客车站建筑设计。
旅客车站布局应符合城镇发展和铁路运输要求,并根据当地经济、交通发展条件,合理确定建筑形式。
铁路旅客车站建筑设计应积极采用安全、节能和符合环境保护要求的先进技术。
客货共线和客运专线铁路旅客车站的建筑规模,应分别根据最高聚集人数和高峰小时发送量按表和表确定。
表客货共线铁路旅客车站建筑规模表客运专线铁路旅客车站建筑规模铁路旅客车站无障碍设计应符合现行《铁路旅客车站无障碍设计规范》(TB10083)和《城市道路和建筑物无障碍设计规范》JGJ50的有关规定。
铁路旅客建筑节能设计应符合现行国家标准《公共建筑节能设计标准》GB50189 的有关规定。
铁路旅客车站建筑设计除应符合本规范外,尚应符合国家现行有关强制性标准的规定。
2 术语铁路旅客车站 railway passenger station为旅客办理客运业务,设有旅客乘降设施,并由车站广场、站房、站场客运建筑三部分组成整体的车站。
客货共线铁路旅客车站 mixed traffic railway line station 设在客货共线运行的铁路沿线,主要办理客运业务的车站。
客运专线铁路旅客车站 passenger dedicated railway line station设在客运专线铁路沿线,专门办理客运业务的车站。
旅客最高聚集人数 maximum passengers in waiting room 旅客车站全年上车旅客最多月份中,一昼夜在候车室内瞬时(8~10min)出现的最大候车(含送客)人数的平均值。
高峰小时发送量 peak hour departing quantum车站全年上车旅客最多月份中,日均高峰小时旅客发送量。
站房平台 platform for station building由站房外墙向城市方向延伸一定宽度,连接站房各个部位及进出口的平台。
客运站的分类
客运站的分类1、按照办理的业务性质划分我国办理客运业务的车站按办理的业务性质划分为专门或主要办理客运业务的客运站,和同时兼办客货运业务的客货运站。
2、按照办理的客运量和技术作业量并考虑政治、经济、文化及在路网中的地位划分(1)按办理的客运量的大小,专门或主要办理客运业务的客运站可划分为特、一、二等站。
(2)按办理的客运量、货运量和技术作业量大小,兼办客运业务(办理综合业务)的车站具备表中三项条件中两项时,可划分为特、一、二、三等站。
此外,办理综合业务的车站按核定等级的依据条件未达到三等站条件时定为四等站,以办理列车会让、越行为主的站定为五等站。
(3)在具体核定办理客运业务的车站等级时,依照前述条件并考虑车站所在地的政治、经济、文化及在路网中的地位等情况,可按下列参考条件酌定车站等级:①首都、中央直辖市及个别省府所在地的车站可酌定为特等站。
②省府所在地的车站及重要国境站、口岸站可酌定为一等站。
③工矿企业比较集中地区所在地的车站和位于三个方向及其以上并担当机车更换、列车技术作业的车站,可酌定为二等站或三等站。
3、按照车站线路布置图型划分按照车站站场上线路的布置图型,客运站分为以下三种:(1)通过式客运站。
通过式客运站是指有一个方向的正线贯穿车站且股道为贯通线的客运站,其旅客站房布置在线路一侧或两侧。
(2)尽端式客运站。
尽端式客运站是指设在正线终端的客运站,布置形式分为两种:①股道的一端连接正线,另一端为尽头线并设有尽端站台。
②股道采用贯通线,一端连接正线,另一端连接段管线(如客车整备所、机务段等),旅客站房布置在线路一侧或两侧。
(3)混合式客运站。
4、按照车站建筑规模划分根据《铁路旅客车站建筑设计规范(2011年版)》(GB 50226—2007)规定,客货共线和高铁客运站的建筑规模分别根据旅客最高聚集人数和高峰小时发送量,特大型、大型、中型、小型客运站。
5、按照车站客运服务质量标准等级划分按照车站客运服务质量标准等级,办理客运业务的车站划分为小站(四、五等站)、中等站(二、三等站)、大站(特、一等站)三个等级。
2022-2023年一级注册建筑师《建筑设计》预测试题17(答案解析)
2022-2023年一级注册建筑师《建筑设计》预测试题(答案解析)全文为Word可编辑,若为PDF皆为盗版,请谨慎购买!第壹卷一.综合考点题库(共50题)1.我国1990年4月1日起施行的《中华人民共和国城市规划法》中提出,编制城市规划一般的阶段划分是:( )A.总体规划和详细规划两个阶段B.总体规划、分区规划和详细规划三个阶段C.区域规划、总体规划、分区规划和详细规划四个阶段D.总体规划、分区规划、控制性详细规划和修建性详细规划四个阶段正确答案:A本题解析:新的《中华人民共和国城乡规划法》2007年10月28日第十届全国代表大会常务委员会第三十次会议通过。
2.按《铁路旅客车站建筑设计规范》的规定,旅客站台在站台全长范围内,应设置明显且耐久的安全标记,标记距站台台面边缘()。
A.0.80mB.0.90mC.1.00mD.1.20m正确答案:C本题解析:《铁路旅客车站建筑设计规范》(GB 50226—2007)(2011年版)第6.1.4条第3款规定,旅客列车停靠的站台应在全长范围内,距站台边缘1m处的站台面上设置宽度为0.06m的黄色安全警戒线,安全警戒线可与提示盲道结合设计。
当有速度超过120km/h的列车临近站台通过时,安全警戒线和防护设施应符合铁路主管部门的有关规定。
3.提出“城市设计必须和城市管理密切结合理论”的是()。
A.雅可布斯(J Jacobs)B.亚历山大(C Alexander)C.培根(E N Bacon)D.十人组合(TEAM10)正确答案:C本题解析:培根继承并发展了“体型环境设计”理论,并在其著作《城市设计》中提出了“城市设计必须和城市管理密切结合理论”把城市设计和管理结合起来。
城市功能上,把空间和运动结合起来,在运动中又把步行和车行(汽车、轨道交通)结合起来,把公共交通和私人交通结合起来,整合成一个“同时运动诸系统”的设计与管理体系。
4.以下是希腊的三个古代建筑遗址,按年代由先至后排序正确的是()。
铁路旅客车站建筑设计规范
中华人民共和国国家标准铁路旅客车站建筑设计规范(报批稿)条文说明目录1总则······················································()3选址和总平面布置·······································()3.1 选址··················································()3.2 总平面布置··················································()4 车站广场·····················································()5站房设计······················································()5.1 一般规定······················································()5.2 集散厅·····················································()5.3 候车区(室)···················································()5.4 售票用房······················································()5.5 行李、包裹用房··············································()5.6 旅客服务设施·················································()5.7 旅客用厕所、盥洗间············································()5.8客运管理、生活和设备用房······································()5.9国境(口岸)站房·············································()6站场客运建筑················································()6.1 站台、雨棚···················································()6.2 站场跨线设施··············································()6.3 站台客运设施···············································()6.4 检票口·················································()7 消防与疏散····················································()7.1 建筑防火·····················································()7.2 消防设施·····················································()8建筑设备····················································()8.1给水、排水·····················································()8.2 采暖、通风和空气调节··········································()8.3 电气、照明·····················································()8.4旅客信息系统··············································()1 总 则1.0.1本规范是在原《铁路旅客车站建筑设计规范》(GB 50226-95)基础上修定的。
铁路旅客车站建筑设计规范
铁路旅客车站建筑设计规范
一、概述
铁路旅客车站建筑设计规范,是为了统一铁路旅客车站建筑的设计标准,保证旅客车
站建筑设计的质量,提高旅客车站建筑的安全性、舒适性和节能性能,满足旅客车站建筑设计需求,促进铁路旅客出行的安全与便利。
二、设计原则
1、功能原则:铁路旅客车站建筑的设计原则是以满足旅客的出行需求为主,要求建
筑功能合理、结构设计合理、空间组织合理、细部设计精致、布局顺畅,以满足旅客的出
行需求为目的。
2、安全原则:安全是铁路旅客车站建筑设计的基本原则,要求建筑结构安全可靠,
功能组织合理,空间布局安全可靠,室内装饰安全可靠,室外设施安全可靠,以确保旅客
安全出行。
3、节能原则:要求建筑结构设计要符合节能原则,采用低耗能建筑材料,采用节能
措施,采用节能设备,以减少能源的消耗和环境的污染,提高社会的效益。
三、设计要求
1、建筑外观:铁路旅客车站建筑设计要求具有明显的时代特征,外观具有一定的美
观性,反映出铁路的现代化特点。
2、建筑结构:铁路旅客车站建筑结构要求结构简洁、节约材料,采用节能结构体系,要求结构安全可靠,耐久性能强,抗风抗震性能好,防火防爆性能优良。
3、空间组织:铁路旅客车站建筑要求妥善安排功能区域,组织空间合理,确保旅客
出行需求,保证安全性能。
4、装饰装修:铁路旅客车站建筑装饰装修要求装饰材料环保、质量可靠、安全性能好,装修设计合理,细部施工精致,以满足旅客出行需求。
四、实施
本规范自发布之日起实施,由有关部门负责实施和监督检查,对不符合规范要求的,
要求重新设计,以保证铁路旅客车站建筑设计的质量。
铁路旅客车站建筑设计规范标准
铁路旅客车站建筑设计规2009-5-4 11:59 【大中小】【打印】【我要纠错】第一章总则1.0.1 为保证铁路旅客车站建筑设计符合安全、适用和卫生等基本要求,制订本规。
1.0.2 本规适用于标准轨距国家铁路旅客车站新建、改建和扩建工程的建筑设计。
1.0.3 铁路旅客车站站房(以下简称站房)除应按设计年度远期的客运量确定规模外,宜预留扩建的余地。
易扩建的站场客运建筑可分期建设。
1.0.4 铁路旅客车站的建筑规模,应根据旅客最高聚集人数(以下简称最高聚集人数),按表1.0.4划分为四级。
铁路旅客车站建筑规模的划分表1.0.41.0.5 铁路旅客车站建筑设计除应符合本规外,尚应符合国家现行有关标准的规定。
第二章术语2.0.1 铁路旅客车站 Railway passenger station为旅客办理客运业务,设有旅客候车和安全乘降设施,并由站前广场、站房、站场客运建筑三者组成整体的车站。
2.0.2 旅客最高聚集人数 Maximum passengers in waiting room旅客车站全年上车旅客最多月份中,一昼夜在候车室瞬时(8~10min)出现的最大候车(含送客)人数的平均值。
2.0.3 站房平台 Platform for station building由站房外墙向城市方向延伸一定宽度,连接站房各个部位及进出站口的平台。
2.0.4 旅客车站专用场地 Special area for passenger station自站房平台外缘至相邻城市道路缘和相邻建筑基地边缘围,包括旅客活动地带与人行通道、车行道、停车场、绿化、建筑小品使用的场地。
2.0.5 公交站点 Bus stop设于站前广场城市公共交通车辆的首末站或中途站。
2.0.6 线侧下式站房 Low—lying station building旅客车站站场线路的高程高于站前广场地面高程,站房首层地面低于站台面,且高差较大,分层布置的站房。
浅谈中小型铁路客站站型的选择
浅谈中小型铁路客站站型的选择张鸿【摘要】合理的站型是功能完善的铁路旅客车站必须具备的条件.分析站场形式、客站站房的建筑规模、车站广场面与站台面的高差、站区地形、设计洪水位或内涝水位等因素对中小型铁路客站的布置及旅客流线的影响,探讨中小型铁路客站站型的选择方法.【期刊名称】《铁道经济研究》【年(卷),期】2016(000)004【总页数】4页(P5-8)【关键词】中小型铁路客站;旅客流线;站型【作者】张鸿【作者单位】中国铁路经济规划研究院,北京100038【正文语种】中文铁路旅客车站是铁路网和铁路枢纽的重要节点,是铁路连接城市的桥梁和纽带。
铁路旅客车站的布置对城市建设的格局、城市交通的设置,以及经济、文化、生活将产生重要影响。
铁路旅客车站主要的功能是铁路旅客换乘及集散,功能要求进出站旅客流线便捷、顺畅,路程短。
影响铁路旅客车站旅客流线的重要因素是客站的站型,合理的站型是功能完善的铁路旅客车站必须具备的条件。
根据现行的《铁路旅客车站建筑设计规范》(GB 50226—2007),铁路旅客车站建筑规模依据所处城市人口、当地经济、交通发展条件预测的客运量,划分为特大型、大型、中型、小型。
一般位于人口多的副省级、首府、计划单列市及以上城市的主要铁路旅客车站才为特大型、大型客站,位于地级市及以下城市的铁路旅客车站及位于大城市的非主要铁路旅客车站均为中小型客站,中小型铁路客站占全国铁路客站数量的90%以上(见表1)。
中小型铁路客站铁路股道数(1~7条)、站台数(1~3座)少,旅客流线相对简单,每年设计的中小型客站数量多(达一百多座),条件相同、相仿的车站可以复制和借鉴,所以中小型铁路客站站型具有研究价值。
铁路旅客车站根据站房与站场线路(站台面)的位置关系分为以下几种基本类型。
2.1 线端式站房位于车站线路端部(见图1)。
2.2 线侧式站房位于车站线路侧面。
根据站房与站场轨道的竖向布置不同,分为三种站型。
1)线侧平式:站房位于车站线路侧面,首层地面(候车室地面,下同)与车站站台面平齐(见图2)。
铁路旅客车站建筑设计规范
铁路旅客车站建筑设计规范第一章总则 1.0.1 为保证铁路旅客车站建筑设计符合安全、适用和卫生等基本要求,制订本规范。
1.0.2 本规范适用于标准轨距国家铁路旅客车站新建、改建和扩建工程的建筑设计。
1.0.3 铁路旅客车站站房(以下简称站房)除应按设计年度远期的客运量确定规模外,宜预留扩建的余地。
易扩建的站场客运建筑可分期建设。
1.0.4 铁路旅客车站的建筑规模,应根据旅客最高聚集人数(以下简称最高聚集人数),按表1.0.4划分为四级。
铁路旅客车站建筑规模的划分表1.0.4第二章术语2.0.1 铁路旅客车站Railway passenger station为旅客办理客运业务,设有旅客候车和安全乘降设施,并由站前广场、站房、站场客运建筑三者组成整体的车站。
2.0.2 旅客最高聚集人数Maximum passengers in waiting room旅客车站全年上车旅客最多月份中,一昼夜在候车室内瞬时(8~10min)出现的最大候车(含送客)人数的平均值。
2.0.3 站房平台Platform for station building由站房外墙向城市方向延伸一定宽度,连接站房各个部位及进出站口的平台。
2.0.4 旅客车站专用场地自站房平台外缘至相邻城市道路内缘和相邻建筑基地边缘范围内,包括旅客活动地带与人行通道、车行道、停车场、绿化、建筑小品使用的场地。
2.0.5 公交站点Bus stop设于站前广场内城市公共交通车辆的首末站或中途站。
2.0.6 线侧下式站房Low—lying station building旅客车站站场线路的高程高于站前广场地面高程,站房首层地面低于站台面,且高差较大,分层布置的站房。
2.0.7 高架跨线候车室Elevated overcrossing waiting room位于旅客站台与线路上方,且与站房相连,主要为候车使用的建筑物。
2.0.8 设计行包库存件数Designed of luggage office设计年度内最高月的日平均行包库存件数。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
1 总则1.0.1 为统一铁路旅客车站建筑设计标准,使铁路旅客车站建筑设计符合“功能性、系统性、先进性、文化性、经济性”的要求,制定本规范。
1.0.2本规范适用于新建铁路旅客车站建筑设计。
1.0.3 旅客车站布局应符合城镇发展和铁路运输要求,并根据当地经济、交通发展条件,合理确定建筑形式。
1.0.4 铁路旅客车站建筑设计应积极采用安全、节能和符合环境保护要求的先进技术。
1.0.5客货共线和客运专线铁路旅客车站的建筑规模,应分别根据最高聚集人数和高峰小时发送量按表1.0.5-1和表1.0.5-2确定。
表 1.0.5-1 客货共线铁路旅客车站建筑规模表 1.0.5-2 客运专线铁路旅客车站建筑规模1.0.6铁路旅客车站无障碍设计应符合现行《铁路旅客车站无障碍设计规范》(TB10083)和《城市道路和建筑物无障碍设计规范》JGJ50的有关规定。
1.0.7 铁路旅客建筑节能设计应符合现行国家标准《公共建筑节能设计标准》GB50189 的有关规定。
1.0.8铁路旅客车站建筑设计除应符合本规范外,尚应符合国家现行有关强制性标准的规定。
2 术语2.0.1铁路旅客车站 railway passenger station为旅客办理客运业务,设有旅客乘降设施,并由车站广场、站房、站场客运建筑三部分组成整体的车站。
2.0.2客货共线铁路旅客车站mixed traffic railway line station设在客货共线运行的铁路沿线,主要办理客运业务的车站。
2.0.3客运专线铁路旅客车站 passenger dedicated railway line station设在客运专线铁路沿线,专门办理客运业务的车站。
2.0.4 旅客最高聚集人数m aximum passengers in waiting room旅客车站全年上车旅客最多月份中,一昼夜在候车室内瞬时(8~10min)出现的最大候车(含送客)人数的平均值。
2.0.5高峰小时发送量peak hour departing quantum车站全年上车旅客最多月份中,日均高峰小时旅客发送量。
2.0.6站房平台 platform for station building由站房外墙向城市方向延伸一定宽度,连接站房各个部位及进出口的平台。
2.0.7旅客车站专用场地s pecial area for passenger station自站房平台外缘至相邻城市道路内缘和相邻建筑基地边缘范围内的区域,包括旅客活动地带与人行通道、车行道、停车场。
2.0.8集散厅c oncourse用于旅客站房内疏导旅客,并设有安检、问询等服务设施的大厅。
2.0.9线下式站房low-lying station building旅客车站站场线路的高程高于车站广场地面高程,站房首层地面低于站台面,且高差较大的站房。
2.0.10高架候车室e levated over-crossing waiting room位于车站站台与线路上方,且与站房相连,主要为候车旅客使用的建筑物。
2.0.11设计行包库存件数de signed capacity of luggage office设计年度内最高月的日平均行包库存件数。
2.0.12站场客运建筑d uildings for passenger traffic in station yard在站场范围内,为客运服务的站台、雨篷、地道、天桥等建筑物以及检票口、站台售货亭、站名牌等设施的统称。
2.0.13旅客信息系统p assenger information system向旅客通告事项,提供各类视、听觉信息,组织客运作业,疏导客流,保证站车及旅客安全,有效地进行客运管理与服务的设施。
2.0.13揭示牌bulletin board向旅客通告事项,提供运营、管理、安全、服务等视觉信息的告知牌。
3 选址和总平面布置3.1 选址3.1.1铁路旅客车站的选址应符合下列规定:1旅客车站应设于方便旅客集散、换乘并符合城镇发展的区域;2有利于铁路和城镇多种交通形式的发展;3少占或不占耕地,减少拆迁及填挖方工程量;4符合国家安全、环境保护、节约能源等有关规定。
3.1.2铁路旅客车站选址不应选择在地形低洼、易淹没以及不良地址地段。
3.2 总平面布置3.2.1铁路旅客车站的总平面布置应包括车站广场、站房和站场客运设施,并应统一规划,整体设计。
3.2.2铁路旅客车站的总平面布置应符合下列规定:1 符合城镇发展规划要求,结合城市轨道交通、公共交通枢纽、机场、码头等道路的发展,合理布局;2建筑功能多元化、用地集约化,并留有发展余地;3 使用功能分区明确,各种流线简捷、顺畅;4 车站广场交通组织方案遵循公共交通优先的原则,交通站点布局合理;5 特大型、大型站的站房应设置经广场与城市交通直接相连的环形车道;6 当站区有地下铁道车站或地下商业设施时,宜设置与旅客车站相连接的通道。
3.2.3铁路旅客车站的流线设计应符合下列规定:1旅客、车辆、行李、包裹和邮件的流线应短捷,避免交叉;2进、出站旅客流线应在平面或空间上分开;3 减少旅客进出站和换乘的步行距离。
3.2.4 特大型站站房宜采用多方向进、出站的布局。
3.2.5特大型、大型站应设置垃圾投放设施和转运站;站内废水、废气的处理,应符合国家有关标准的规定。
3.2.6车站的各种室外地下管线应进行总体综合布置,并应符合现行《城市工程管线综合规划规范》(GB50289)的有关规定。
4 车站广场4.0.1车站广场宜由站房平台、旅客车站专用场地、公交站点及绿化景观用地四部分组成。
4.0.2 车站广场设计应符合下列规定:1车站广场应与站房、站场布置密切结合,并符合城镇规划要求;2车站广场内的旅客、车辆、行李和包裹流线应短捷,避免交叉;3 人行通道、车行通道应与城市道路互相衔接;4除绿化用地外,车站广场应采用刚性地面,并符合排水要求;5 特大型和大型旅客车站宜采用立体车站广场;6 季节性或节假日客流大的车站,其车站广场应有设置临时候车设施的条件。
4.0.3客货共线铁路旅客车站专用场地最小面积应按最高聚集人数确定,客运专线铁路旅客车站专用场地最小面积应按高峰小时发送量确定,其最小面积指标均不宜小于4.8m2/人。
4.0.4 站房平台设计应符合下列规定:1平台长度不应小于站房主体建筑的总长;2 平台宽度,特大型站不宜小于30m,大型站不宜小于20m,中型站不宜小于10m,小型站不宜小于6m;3 立体车站广场的平台应分层设置,每层平台的宽度不宜小于8m。
4.0.5旅客活动地带与人行通道的设计应附符合下列规定:1 人行通道应与公交(含城市轨道交通)站点相通;2 旅客活动地带与人行通道的地面应高出车行道,并不应小于0.12m。
4.0.6客货共线铁路的特大型、大型和中型旅客车站的行李、包裹托取厅附近应设停放车辆的场地。
4.0.7 车站广场绿化率不宜小于10%,绿化与景观设计应按功能和环境要求布置。
4.0.8出境入境的旅客车站应设置升挂国旗的旗杆。
4.0.9 当城市轨道交通与铁路旅客车站衔接时,其旅客进出站流线应顺畅衔接。
4.0.10城市公交、轨道站点设计应符合下列规定:1 城市公交、轨道交通站点应设于安全部位,并应方便旅客乘降及换乘。
2公交站点应设停车场地,停车场面积应符合当地公共交通规划的要求,当无规定时,公交停车场最小面积宜根据最高聚集人数或高峰小时发送量,且不宜小于1.0m2/人。
3 公交站点设计应符合现行《城市公共交通站、场、厂设计规范》(CJJ15)的有关规定;4 当铁路旅客车站站房的进站和出站集散厅与城市轨道交通的站厅连接,且不在同一平面时,应设垂直交通设施。
4.0.11广场内的各种揭示和引导系统应醒目,其结构、构造应设置安全。
4.0.12车站广场应设置厕所,最小使用面积可根据最高聚集人数或高峰小时发送量按每千人不宜小于25㎡或4个厕位确定。
当规模较大时宜分散布置。
5站房设计5.1一般规定5.1.1站房内应按功能分为公共区、设备区和办公区,各区应划分合理,功能明确,便于管理,并应符合下列规定: 1公共区应设置为开敞、明亮的大空间,旅客服务设施齐备,旅客流线清晰、组织有序。
2 设备用房应远离公共区设置,并充分利用地下空间。
3 办公用房宜集中设于站房次要部位,并与公共区有良好的联系条件,与运营有关用房应靠近站台。
5.1.2 站房设计应符合国家有关安全、节约能源、环境保护和防火等规定的要求。
5.1.3 当站房与城市轨道交通站点合建时,应整体规划,统一设计。
5.1.4线侧式站房设置多层候车室时,应设置与站台相连的跨线设施。
5.1.5 站房的进出站通道、换乘通道、楼梯、天桥和检票口应满足旅客进出站高峰通过能力的需要,其净宽度每100人不应小于0.65m;地道净宽度每100人不应小于1.00m。
5.1.6特大型、大型和中型站应有设置防爆及安全检测设备的位置。
5.1.7旅客站房宜独立设置。
当与其他建筑合建时,应保证铁路旅客车站功能的完整和安全。
5.1.8站房内综合管线宜集中布置,并满足防火要求。
5.1.9 客运专线铁路旅客车站可不设行李、包裹用房。
5.2 集散厅5.2.1中型及以上的旅客车站宜设进站、出站集散厅。
客货共线铁路车站应按最高聚集人数确定其使用面积,客运专线铁路车站应按高峰小时发送量确定其使用面积,且均不宜小于0.2m2/人。
5.2.2集散厅应有快速疏导客流的功能。
5.2.3特大型、大型站的站房内应设自动扶梯,中型站的站房宜设置自动扶梯。
5.2.4进站集散厅内应设有问询、邮政、电信等旅客服务设施。
5.2.5 大型及以上站的出站集散厅内应设有电信、厕所等旅客服务设施。
5.3 候车区(室)5.3.1客货共线铁路旅客车站站房可根据车站规模设普通、软席、军人(团体)、无障碍候车区及贵宾候车室。
各类候车区(室)候乘人数占最高聚集人数的比例可按表5.3.1确定。
表 5.3.1 各类候车区(室)计算比例(﹪)注:1有始发列车的车站,其软席和其他候车室的比例可根据具体情况确定;2无障碍候车区(室)包含母婴候车区位,母婴候车区内宜设置母婴服务设置。
3小型车站应在候车室设置无障碍轮椅候车位。
5.3.2 客运专线铁路车站候车区总使用面积应根据高峰小时发送量,按不应小于 1.2m2/人确定。
各类侯车区(室)的设置可根据按具体情况确定。
5.3.3客货共线铁路旅客车站候车区总使用面积应根据最高聚集人数,按不应小于1.2m2/人确定。
小型站候车区的使用面积宜增加15%。
5.3.4候车区(室)设计应符合下列规定:1普通、软席、军人(团体)和无障碍候车区宜布置在大空间下,并可采用低矮轻质隔断划分各类候车区。
2利用自然采光和通风的候车区(室),其室内净高宜根据高跨比确定,并不宜小于3.6m。