塔吊整改通知单
塔吊手续不齐全使用监理通知单范本
塔吊手续不齐全使用监理通知单范本
英文回答:
I recently encountered a situation where the tower
crane on a construction site did not have all the necessary permits and documentation. This is a serious issue as it
can pose a risk to the safety of the workers and the public. In such cases, it is important to use a notice template to inform the contractor and the site supervisor about the incomplete paperwork and the need for immediate action.
The notice should clearly state the specific permits
and documents that are missing or incomplete. For example,
it could mention that the tower crane does not have a valid operating license, or that the necessary inspections and certifications have not been obtained. It is important to provide specific details and evidence to support these claims, such as photographs or copies of relevant documents.
塔吊手续不齐全使用监理通知单范本
塔吊手续不齐全使用监理通知单范本
编号:XXXXXX
日期:XXXX年XX月XX日
致:施工单位
根据现场检查发现,您单位所使用的塔吊存在手续不齐全的情况,违反了《建筑施工安全规范》相关规定。现通知如下:
1.塔吊手续不齐全的问题
经过检查,发现您单位所使用的塔吊存在以下问题:
(1)塔吊安全证书已过期;
(2)塔吊日常检查记录不完整;
(3)塔吊操作人员未持有效证件。
2.要求整改措施
要求施工单位立即采取以下措施进行整改:
(1)重新办理塔吊安全证书;
(2)完善塔吊日常检查记录;
(3)确保塔吊操作人员持有效证件。
3.整改期限
整改期限为通知下发之日起3个工作日内完成,并向监理单位提
交整改报告。
4.督促检查
监理单位将对整改情况进行督促检查,确保问题得到及时解决。
如整改不到位,将依法采取相应的处罚措施。
5.相关责任
若发生事故,由于上述问题造成,将追究相关人员和单位的责任,严格依法处理。
请贵单位对上述问题高度重视,立即采取有效措施进行整改,并
配合监理单位的工作。如有任何疑问,请及时与监理单位联系。
特此通知。
监理单位:__________签字:__________日期:__________
施工单位:__________签字:__________日期:__________
以上为监理通知单范本,希望对您的工作有所帮助。祝您工作顺利!
塔吊通知单
.实用文档.
. 监理通知单
工程名称:东兴洲片区还建房H1地块编号: 20160425 致:湖北弘诚建设集团有限公司(施工项目经理部)
事由:
关于塔吊使用安全问题
内容:
1#楼、2#楼塔吊设备未检测、未备案就投入使用,为保证施工安全,现
要求施工单位立即停止使用塔吊,待第三方检测报告及相关手续完善后方可使
用。
抄送:武汉大华东兴房地产有限公司
项目监理机构(盖章)
总/专业监理工程师(签字)
年月日
注:本表一式三份,项目监理机构、建设单位、施工单位各一份。
隐患整改通知单表
项目工程安全隐患整改通知书
注:此表至少一式2份,检查单位、被检单位各一份。
项目工程安全隐患通知书
注:此表至少一式2份,检查单位、被检单位各一份。
项目工程安全隐患整改告知书
注:此表至少一式2份,检查单位、被检单位各一份。
项目工程安全隐患整改告知书
注:此表至少一式2份,检查单位、被检单位各一份。
注:此表至少一式2份,检查单位、被检单位各一份。
注:此表至少一式2份,检查单位、被检单位各一份。
注:此表至少一式2份,检查单位、被检单位各一份。
注:此表至少一式2份,检查单位、被检单位各一份。
注:此表至少一式2份,检查单位、被检单位各一份。
注:此表至少一式2份,检查单位、被检单位各一份。
注:此表至少一式2份,检查单位、被检单位各一份。
注:此表至少一式2份,检查单位、被检单位各一份。
注:此表至少一式2份,检查单位、被检单位各一份。
注:此表至少一式2份,检查单位、被检单位各一份。
工程名称:南白镇播州时代中心工程编号:20170120
建筑工程安全隐患整改通知单
工程名称:南白镇播州时代中心工程编号:20170120
建筑工程安全隐患整改通知单
安全隐患整改复查意见书项目名称:播州时代中心
建筑工程通知单
建筑工程安全隐患整改通知单
工程名称:南白镇播州时代中心工程编号:20170405
建筑工程安全隐患整改通知单
工程名称:播州时代中心工程编号:20170420
电梯井防护门、楼梯栏杆未搭设!
2、3号楼28层外架悬挑层未按要求进行水平封闭防护!建筑垃圾未清.
28层洞口、建筑材料垃圾
建筑工程安全隐患整改通知单
工程名称:播州时代中心工程编号:20170531
施工现场起重机械设备安全隐患限期整改通知书
编号::
根据《建设工程安全生产管理条例》、《特种设备安全监察条例》、《起重机械监督检验规程》、《塔式起重机安全规程》(GB5144-1994)、《塔式起重机技术条件》(GB/T9462-1988)、《施工升降机监督检验规程》、《施工升降机检验规则》(GB10053-1996)、《施工升降机安全规则》(GB10055-1996)等,经检查发现你单位施工的工程中使用的起重机械设备存在下列安全隐患:
□特种设备作业人员未按照规定经专门的培训并取得特种作业操作资格证书,上岗作业。
□特种设备作业人员数量配备不足,其中有操作司机人、起重指挥人、司索工人、安装工人。
□无以下技术资料或以下技术资料不全:
1、安装拆卸资质证书;
2、安装拆卸方案;
3、产品合格证;
4、设备制造许可证;
5、安装自验记录;
6、安装施工或设备租赁合同;
7、装拆及使用安全技术交底记录。
□安装拆卸方案和安装自验记录无审批手续或审批手续不符合要求。
□塔吊力矩限制器、重量限制器不灵敏;超高或变幅、行走、回转限位器不灵敏。
□塔吊吊钩保险装置或卷扬机卷筒保险装置、上人爬梯护圈不符合要求。
□塔吊基础不符合规范、标准、设计要求;积水、无排水措施;行走式轨道基础不符合要求。
□塔吊附墙装置安装不符合要求;两台以上塔吊作业防碰撞措施不可靠。
□外用电梯限速器未按规定进行检测标定;无上下极限限,或不符合要求;门连锁、制动器不符合要求。
□外用电梯层间卸料口的防护门、卸料平台、防护棚的搭设不符合要求。
□外用电梯超过规定承载人数或超过规定重量无控制措施;有对重电梯未加对重载人。
塔吊基坑积水隐患整改通知范本
塔吊基坑积水隐患整改通知范本
工地旬检查记录表工程名称:xxx省建设工程质量监督总站监制
日期:xxx
整改人签章:xxx
复检人签章:xxx
工地负责人(施工员)签章:xxx
参检人员签章:xxx
受检单位负责人签字受检工程经检查存在下列隐患和问题:塔吊基坑积水隐患整改
处理意见:按下列意见第5条执行。
1、停工整改,在未整改完毕及验收合格之前不得继续施工。
日前整改完毕,整改期限完二日内书面报告检查单位。检查单位检查人员发出日期注:本通知书一式2份,检查单位、受检单位各1份。
监理通知单(对于3塔吊发生起吊钢筋坠落事故整改通知)
监理通知单(对于3塔吊发生起吊钢筋坠落事故整改通知)
浙建监B1
监理工程师通知单
工程名称:
编号:B1
致
:
抄送:
事由:关于塔吊发生起吊钢筋坠落事故的整改通知本项目塔吊在吊装钢筋过程中,发生一起成捆钢筋从空中坠落在钢筋加工防护棚边上的事故,,造成一名正在棚边加工钢筋的工人发生轻度擦伤,加工台变形等事故。我方现场监理人员立即着手进行施工调查,初步分析是钢丝绳起吊夹具变形、夹具螺丝未拧到位的原因。加上现场无专职持证司索工指挥,且钢筋加工机械擅自移出操作棚所致。
针对以上事故我项目监理部要求贵司立即组织一次安全事故教育活动,彻底分析事故原因、查明责任人,并要求对塔吊钢丝绳进行检查。在每天使用前班组自查发现磨损及时更换;对仅采用中间单点支撑的防护棚采取加固防倾覆措施,加工机械必须立即移入棚内,操作人员必须在棚内作业,司索工等特殊工种必须立即持证上岗。同时要求在项目部内对本次事故公告通报,教育全体施工人员警钟长鸣,共同做好安全工作。
另外建议业主对照合同要求对施工单位进行必要的处罚,以促使施工单位引起重视。
附件:事故现场照片
项目监理机构
总/专业监理工程师
日
期
本表一式三份,建设单位、监理单位、承包单位各存一份。
塔吊手续不齐全使用监理通知单范本
塔吊手续不齐全使用监理通知单范本
英文回答:
As a construction supervisor, I have encountered situations where the tower crane did not have all the necessary permits and documentation in place. This can be a serious issue as it not only poses a safety risk but also violates regulations. In such cases, I would issue a notice to the contractor using a template to inform them of the deficiencies and request immediate action to rectify the situation.
The notice would typically include details of the specific permits or documentation that are missing or incomplete, as well as a deadline for when these issues need to be resolved. It is important to be clear and firm
in such communications to ensure that the contractor understands the seriousness of the situation.
塔吊隐患通知书
塔吊隐患通知书
工程指挥部:
20 年月日,我局派副局长、科长带队的安全生产管理小组,对你方施工的工程项目进行安全隐患检查,发现如下问题,你方需引起高度重视。
1、塔吊钢丝绳多处磨损
2、塔身爬梯松动
3、塔吊塔身结构变形
4、滑轮锈蚀严重
5、塔吊电机漏油严重
上述严重问题已经拍照存档,并录入我局安全系统,塔吊安全关系到工人的生命安全和工程质量的交付结果,必须引起高度重视。
以上隐患,需要你方做出相应整改,整改要求如下:
1、更换磨损的钢丝绳
2、松动的塔身爬梯加固
3、刷漆处理并补漏
4、锈蚀滑轮刷漆或直接更换
5、修复松动变形的塔身
我局复查小组将在20天后予以复查,若仍旧出现类似问题,将给予贵公司一定的处罚金额。
特此通知!
安全小组负责人签字:
工程现场负责人签字:
塔吊整改负责人签字:
市安全监督管理局(盖章)
20 年月日
加强对塔吊使用管理的通知
关于加强对塔吊使用管理的通知
各施工单位要加强对塔吊和信号工的管理,不在有违章、违规现象,确保在作业时能够安全使用塔吊。塔司和信号工在作业时还存在以下问题:吊物离地面没有试吊(50cm停住);吊零散物料时没有用容器;长短不一、捆绑不牢或吊点不在重心;有向下抛掷烟头现象;“十不吊”遵守不严,对信号指挥错误或未采取防范措施。信号工选择站位不准确,吊物离地没有试吊,离起落物较远,有兼做挂钩工现象;人员配备不足;未佩戴信号服,擅自离岗,吊物重心偏离;吊运大模板不用双耳环吊运,和两块一起吊;和塔司配合不协调等。
一、对塔司和信号工的要求:
1、上班必须办理交接班手续,检查机械履历书及交接班记录等的填写情况及记载事项。
2、必须在佩有指挥信号袖标的人员指挥下,严格按照指挥信号(对讲机、旗语、手势)进行操作。
3、严禁酒后作业。
4、操作前应发出音响信号,对指挥信号分辨不清时,不得盲目操作。
5、严格执行“十不吊”管理规定。
6、对信号工指挥错误时,有权拒绝执行或主动采取紧急防范措施。
7、操作控制器时,必须从零点开始,推到第一挡,然后逐级加档,每挡停1~2秒,直到最高档。
8、被吊物品严禁超出施工现场范围。
9、起吊重物时,应先将重物调离地面50cm停止,确定制动,物料捆扎和吊索具确认无误后,方可指挥起升。
10、严禁重物自由下落,当起重物下降接近就位点时,必须采取慢速就位。
11、重物就位时,可用制动器使之缓慢降下。
12、当钓钩滑轮组升到接近起重臂时,应用低速起升。
13、起重量、起升高度、变幅等安全装置显示或接近临界警报值时,司机必须严密注视,严禁强行作业。
塔机整改回复单
整改回复单
赤峰市特种设备监督检验所
经你单位监督检验,克旗旅游商贸广场A公馆3#楼使用的
塔式起重机:
问题和意见:
1、设备基础螺栓松动,应紧固;
2、力矩限制器、起重限制器失效应调试可靠动作;
3、司机室应加设绝缘地板载荷图表,安全操作规程。
存在以上问题请于2013年5月13日前将处理结果报送监检机构,整改合格前该设备不得投入适用。
经处理并整改结果如下
1、设备基础螺栓松动已经紧固;
2、力矩限制器、起重限制器已调试可靠动作;
3、司机室已经加设绝缘地板载荷图表,安全操作规程。
受检单位主管负责人:日期(受检单位公章)安装单位主要负责人:2013年5月9日现场监理单位负责人:
赤峰市特种设备监督检验所
经你单位监督检验,克旗旅游商贸广场A公馆1#楼使用的
塔式起重机:
问题和意见:
1、基础有杂物,及时清理;
2、接地应加设;
3、机上PE线应加设;
4、司机室内应加设灭火器、载荷图表、操作规程、绝缘地板;
5、力矩限位器、高度限位器、起重限位器、回转限位器、行程限位器
均失效,应调试可靠动作。
经处理并整改结果如下
1、基础下杂物已全部清理;
2、接地已架设;
3、PE线已加设;
4、司机室内灭火器、载荷图表、操作规程、绝缘地板全部安装到位;
5、力矩限位器、高度限位器、起重限位器、回转限位器、行程限位器
均失效,已调试靠动作。
受检单位主管负责人:日期(受检单位公章)
安装单位主要负责人:2013年5月9日
现场监理单位负责人:
赤峰市特种设备监督检验所
经你单位监督检验,克旗旅游商贸广场A公馆2#楼使用的塔式起重机:
问题和意见:
1、司机室应设荷载图表,操作规程;
关于加强塔吊安拆安全管理的通知范文
关于加强塔吊安拆安全管理的通知范文下载提示:该文档是本店铺精心编制而成的,希望大家下载后,能够帮助大家解决实际问题。文档下载后可定制修改,请根据实际需要进行调整和使用,谢谢!本店铺为大家提供各种类型的实用资料,如教育随笔、日记赏析、句子摘抄、古诗大全、经典美文、话题作文、工作总结、词语解析、文案摘录、其他资料等等,想了解不同资料格式和写法,敬请关注!
Download tips: This document is carefully compiled by this editor. I hope that after you download it, it can help you solve practical problems. The document can be customized and modified after downloading, please adjust and use it according to actual needs, thank you! In addition, this shop provides you with various types of practical materials, such as educational essays, diary appreciation, sentence excerpts, ancient poems, classic articles, topic composition, work summary, word parsing, copy excerpts, other materials and so on, want to know different data formats and writing methods, please pay attention!
工地塔吊拆除通知单
工地塔吊拆除通知单
各位施工人员:
根据工地施工进展情况,现需对工地上的塔吊进行拆除工作。为了确保作业安全及顺利完成拆除工作,请各位施工人员务必严格遵守以下规定:
1. 拆除工作将于本月**号开始,预计持续**天。期间请避免进入拆除区域,以免发生意外。
2. 拆除工作期间,请全体施工人员密切配合,并听从现场指挥安排,确保施工进展顺利。
3. 拆除作业完成后,请做好现场清理工作,确保工地环境整洁。
请各位施工人员遵守以上规定,共同维护施工现场秩序,确保施工安全。感谢您的配合与支持!
此致
敬礼
工地管理部门敬上
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
1、高度限位器失效
2、第一道附着东侧连杆有一件下垂变形,未张紧
3#楼
1、力矩限制器无效
2、司机室内外卫生差,烟头杂物堆积应清理并注意防火。
4#东楼
1、附着(最顶)架以Fra Baidu bibliotek塔身节间螺栓、附着连墙螺栓均有个别松动。
2、高度限位器失效。
3、输电线缆需规范防护固定,现在转台处电缆铰接,应松开铰接部分。
4#西楼
隐患整改通知单
表格编号
CSMGC-JL(Ⅰ)-AQ01-04
制度名称
中国二冶集团有限公司安全生产管理制度
制度编号
CSMGC-GZ(Ⅰ)-AQ01-2015
工程名称
徐家楼新华片区棚改一期项目
施工单位
泰安市中宇经贸有限公司
项目经理
王志永
检
查
内
容
及
存
在
问
题
隐患情况另附照片:
1#楼
1、高度限位器失效
2、吊具吊索要经常检查确保安全使用
1、高度限位器失效
2、上下转台与回转支承处连接螺栓松动。
限改期限
检查部门:(盖章)
检查人:(签字)
受检单位:(盖章)