M1A3P600-1VQG144PP中文资料(Actel)中文数据手册「EasyDatasheet - 矽搜」
埃森平台 MW 系列微型电路保护器说明书
Protective Devices Miniature Circuit Breakers PLN4Catalog1.11EATON CORPORATION CA019074ENProtective DevicesMiniature Circuit Breakers PLN4 (MW)• T op-quality miniature circuit breakers 1P+N with a width of 1 module unit requiring little space for installation• Contact position indicator red - green • Guide for secure terminal connection • C omprehensive range of accessories can be mounted subsequently • Rated currents up to 40 A • Tripping characteristics B, C• R ated breaking capacity 4.5 kA according to IEC/EN 60898-1DescriptionSG157112EATON CORPORATION CA019074EN 3EATON CORPORATION CA019074ENSpecifications | Miniature Circuit Breakers PLN6, PLN4Description• High selectivity between MCB and back-up fuse due to low let-through energy • B usbar positioning optionally above or below • Compatible with standard busbar• Switching toggle in colour designating the rated current • M eets the requirements of insulation co-ordination, distance between con-tacts ³ 4 mm, for secure isolation • 1-pole breaking capacityI cn 1 = 3 kA Accessories:Auxiliary switch for subsequent installation ZP-IHK 286052ZP-WHK 286053Tripping signal switch for subsequent installation ZP-NHK 248437Remote control and automatic switching device Z-FW/LP 248296Shunt trip release ZP-ASA/..248438, 248439Undervoltage releaseZ-USA/..248288-248291Busbars:see capter busbar systemsTechnical DataPLN6, PLN4ElectricalDesign according toCurrent test marks as printed onto the device IEC/EN 60898-1Rated voltage U n 230 VAC Rated frequency50/60 Hz Rated breaking capacity according to IEC/EN 60898-1I cnPLN6 6 kA PLN4 4.5 kA Characteristic B, CBack-up fuse>6 kA max. 100 A gL/gG >4.5 kA max. 80 A gL/gG Selectivity class3Endurance electrical components ³ 8,000 switching operationsMechanical Frame size 45 mm Device height 80 mmDevice width 17.5 mm (1MU for 1+N)Mountingquick fastening with 2 lock-in positions on DIN rail IEC/EN 60715Degree of protectionIP20Upper and lower terminals open-mouthed/lift terminalsTerminal protection finger and hand touch safe, DGUV VS3, EN 50274Terminal capacity1-16 mm 2Connection diagram1+N-poleDimensions (mm)Rated current I n (A)TypeDesignationArticle No.Units per package4.5 kA, Characteristic BSG157116PLN4-B6/1N 26317912/12010PLN4-B10/1N 26318012/12013PLN4-B13/1N 26318112/12016PLN4-B16/1N 26318212/12020PLN4-B20/1N 26318312/12025PLN4-B25/1N 26318412/12032PLN4-B32/1N 26318512/12040PLN4-B40/1N26318612/1201+N-pole4.5 kA, Characteristic CSG157116PLN4-C6/1N 26318912/12010PLN4-C10/1N 26319012/12013PLN4-C13/1N 26319112/12016PLN4-C16/1N 26319212/12020PLN4-C20/1N 26319312/12025PLN4-C25/1N 26319412/12032PLN4-C32/1N 26319512/12040PLN4-C40/1N26319612/1201+N-pole Explanation PLN4:P = xPole , LN = Miniature Circuit Breakers 1P+N, 1MU , 4 = 4.5 kA4EATON CORPORATION CA019074EN5EATON CORPORATION CA019074ENShort-circuit Selectivity PLN4In case of short-circuit, there is selectivity between the miniature circuit breakers PLN4 and the upstream fuses up to the specified values of the selectivity limit current I s [kA] (i. e. in case of short-circuit currents I ks under I s only the MCB will trip, in case of short-circuit currents above this value both protective devices will respond).*) basically in accordance with EN 60898-1 D.5.2.bShort-circuit selectivity Characteristic B towards fuse link DII-DIV *)Short-circuit selectivity Characteristic C towards fuse link DII-DIV *)PLN4DII-DIV gL/gG I n [A]20253550638010060.7 1.2 2.9 4.52) 4.52) 4.52) 4.52)100.60.9 1.9 3.1 4.52) 4.52) 4.52)130.50.7 1.5 2.5 4.52) 4.52) 4.52)160.50.7 1.4 2.3 4.3 4.52) 4.52)200.50.7 1.4 2.2 4.0 4.52) 4.52)250.50.6 1.3 2.0 3.8 4.52) 4.52)320.50.6 1.2 1.8 3.4 4.52) 4.52)40<0.51)0.61.1 1.7 3.1 4.52) 4.52)Short-circuit selectivity Characteristic B towards fuse link D01-D03*)Short-circuit selectivity Characteristic C towards fuse link D01-D03*)PLN4DII-DIV gL/gG I n [A]2025355063801002 1.5 3.8 4.52) 4.52) 4.52) 4.52) 4.52)40.7 1.2 3.3 4.52) 4.52) 4.52) 4.52)60.7 1.1 2.6 4.52) 4.52) 4.52) 4.52)100.50.8 1.7 2.8 4.52) 4.52) 4.52)130.50.7 1.5 2.5 4.52) 4.52) 4.52)160.50.6 1.2 2.0 3.6 4.52) 4.52)200.50.61.2 1.8 3.3 4.52) 4.52)25<0.51)0.6 1.1 1.7 3.0 4.52) 4.52)32<0.51)0.6 1.0 1.6 2.8 4.52) 4.52)40<0.51)0.6 1.0 1.5 2.6 4.0 4.52)PLN4D01-D03 gL/gG I n [A]20253550638010060.60.9 2.5 4.52) 4.52) 4.52) 4.52)100.50.8 1.6 3.4 4.52) 4.52) 4.52)130.50.7 1.3 2.7 4.0 4.52) 4.52)160.50.6 1.3 2.5 3.8 4.52) 4.52)20<0.51)0.61.32.43.64.52) 4.52)25<0.51)0.6 1.2 2.3 3.3 4.52) 4.52)32<0.51)0.6 1.1 2.1 3.0 4.52) 4.52)40<0.51)0.6 1.0 2.0 2.8 4.52) 4.52)PLN4D01-D03 gL/gG I n [A]2025355063801002 1.1 2.0 4.52) 4.52) 4.52) 4.52) 4.52)40.60.9 2.7 4.52) 4.52) 4.52) 4.52)60.60.9 2.3 4.52) 4.52) 4.52) 4.52)100.50.7 1.5 3.0 4.52) 4.52) 4.52)130.50.71.32.7 4.0 4.52) 4.52)16<0.51)0.6 1.1 2.23.14.52) 4.52)20<0.51)0.6 1.1 2.1 2.9 4.52) 4.52)25<0.51)0.5 1.0 2.0 2.7 4.52) 4.52)32<0.51)0.5 1.0 1.9 2.6 4.52) 4.52)40<0.51)0.50.9 1.7 2.3 4.0 4.52)1) Selectivity limit current I sunder 0.5 kA2) S electivity limit current I s = rated breaking capacity I cn of the MCBShort-circuit selectivity Characteristic B towards fuse link NH-00*)Short-circuit selectivity Characteristic C towards fuse link NH-00*)PLN4NH-00 gL/gG I n [A]202532354050638010060.50.91.52.33.24.52) 4.52) 4.52) 4.52)10<0.51)0.7 1.2 1.5 2.0 3.1 3.9 4.52) 4.52)13<0.51)0.6 1.0 1.3 1.7 2.5 3.1 4.52) 4.52)16<0.51)0.6 1.0 1.3 1.6 2.4 2.9 4.52) 4.52)20<0.51)0.50.9 1.3 1.5 2.3 2.8 4.3 4.52)25<0.51)0.50.9 1.1 1.4 2.1 2.6 4.0 4.52)32<0.51)0.50.8 1.0 1.3 1.9 2.4 3.6 4.52)40<0.51)0.50.80.9 1.1 1.7 2.2 3.3 4.52)PLN4NH-00 gL/gG I n [A]202532354050638010020.7 2.1 4.52) 4.52) 4.52) 4.52) 4.52) 4.52) 4.52)40.50.9 1.6 2.6 3.7 4.52) 4.52) 4.52) 4.52)60.50.8 1.4 2.1 2.9 4.52) 4.52) 4.52) 4.52)10<0.51)0.6 1.0 1.4 1.9 2.8 3.5 4.52) 4.52)13<0.51)0.60.9 1.3 1.7 2.5 3.1 4.52) 4.52)16<0.51)0.50.7 1.0 1.3 2.0 2.5 3.8 4.52)20<0.51)0.50.70.9 1.2 1.8 2.3 3.5 4.52)25<0.51)0.50.70.9 1.1 1.6 2.1 3.3 4.52)32<0.51)<0.51)0.60.8 1.1 1.5 2.0 3.1 4.52)40<0.51)<0.51)0.60.8 1.0 1.4 1.9 2.9 4.52)Load Capacity PLN4Let-through Energy PLN4Determined according to 60898-1.Maximum let-through energy PLN4, Characteristic BMaximum let-through energy PLN4, Characteristic CLoad capacity in case of MCB block installationCurrent carrying capacity at ambient temperature (I n = 2-13 A)Permitted permanent load at ambient temperature T (°C) with n devices: I DL = I n K T (T)K N (N).Current carrying capacity at ambient temperature (I n = 16-25 A)Current carrying capacity at ambient temperature (I n = 32, 40 A)Number of devices (n)L o a d c a p a c i t y f a c t o r K N500300500100015002000300040005000600070001000015000800090004009007008006001500100030002000500040002000090007000100008000600015000300005000060000400007000080000prospektiver Kurzschlußstrom [A]D u r c h l a ße n e r g i e I t [A s e c ]22prospektiver Kurzschlußstrom [A]D u r c h l a ße n e r g i e I t [A s e c ]22500300500100015002000300040005000600070001000015000800090004009007008006001500100030002000500040002000090007000100008000600015000300005000060000400007000080000Prospective short-circuit current [A]L e t t h r o u g h e n e r g y I 2t [A 2 s e c ]Prospective short-circuit current [A]L e t t h r o u g h e n e r g y I 2t [A2 s e c ]EatonEMEA Headquarters Route de la Longeraie 71110 Morges, Switzerland Eaton.eu© 2020 EatonAll Rights Reserved Printed in AustriaPublication No. CA019074EN Article number 302799-MK July 2023Grafics: SRA, Schrems9010238178694Eaton Industries (Austria) GmbH Scheydgasse 421210 Vienna AustriaFollow us on social media to get the latest product and support information.Eaton is a registered trademark.All other trademarks are property of their respective owners.To contact us please visit https:///contacts For technical questions please contact your local Eaton team.Changes to the products, to the information contained in thisdocument, and to prices are reserved; as are errors and omissions.Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to trademarks (especially Eaton, Moeller,and Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton Internet pages and Eaton order confirmations.Eaton is an intelligent power management company dedicated toimproving the quality of life and protecting the environment for people everywhere. We are guided by our commitment to do business right, to operate sustainably and to help our customers manage power - today and well into the future. By capitalizing on the global growth trends of electrification and digitalization, we’re accelerating the planet’s transition to renewable energy, helping to solve the world’s most urgent power management challenges, and doing what’s best for our stakeholders and all of society.For more information, visit .。
猎豹工业14-尺寸门闩系统说明书
operación que completamentePORTONES BATIENTESincorporadoestándarde lujocajas de controlMecánicoReducción primaria: engranaje de gusano (tornillo sin fin) 1:27Velocidad: 90°en aproximadamente 12 segundos Exterior: aluminio sacadoMovimiento usable de la barra: 14.75”Desconexión ManualSe proporciona Desconexión por llave“Fail-secure” mecánico ( se aseguran las puertas cuando hay un corte del suministro eléctrico)NotaSe requieren los dispositivos secundarios de laprevención contra el atrapamiento con este operador de puertaCaracterísticas AvanzadasMecanismo de impulsión completamente encerrado Interruptores de límite ajustables incorporados que controlan con exactitud la velocidad de empezar /parar , y el movimiento del portón para una operación suave115 VAC entrada de energía 24 VDC energía de funcionamiento Se incluyen bateríasCargador de batería incorporadoPuertos para enchufar detectores para la salida o regresar90°en aproximadamente 12 segundos 110°máximo de apertura de la puertaCaracterística que permite operar portones batientes dualesCircuito de la energía de la cerradura magnética Interruptores incorporados de reajuste y de pruebaT emporizador del máximo funcionamiento Advertencia de alta corriente incorporadoTemp de Operación32°F hasta 145°F 0°C hasta 62°CReglamentario de SeguridadSatisface las normas de seguridad de UL 325y UL 991Listado ETLPeso de EnvíoAproximadamente 20-25 libras (9-11.3 kg)GarantíaGarantía de fábrica limitada de 2 añosClase de Máximo Longitud Máximo Peso Energíaoperación del Portón *del Portón *Tablero de Control ActuadorRespaldo I, II 14 Ft 500 Lbs.115 VAC, 60 Hz 24 VDCSe provee baterías4.3 m 227 kgd e l t a b l e r o d e c o n t r o l6002 EspecificacionesEspecificaciones Generales*Asume que la puerta y el material esta en buena condición y oscila en un plano nivelado6002 Actuador50" L x 4" H x 4" D1270mm W x 101mm H x 101mm DEl actuador del portón batiente del modelo 6002 ofrece conveniencia y confiabilidad en un diseño compacto. Se monta directamente en el portón y pilastra, simplificando la instalación y eliminando la necesidad de plataformas de concreto. El pistón impulsadopor el tornillo potente se conecta directamente al portón eliminando conexiones mécanicas débiles y es completamente encerrado para prevenir la suciedad y otros corrosivos transportados por el viento de contaminar la rosca del tornillo. Y no haynecesidad de preocuparse de los escapes, de las válvulas o de las bombas hidráulicas.Caja de Control Estándar 12.25" W x 16.75" H x 4" D(311mm W x 425mm H x 101mm D)Caja de Control de Lujo 14.25" W x 24.25" H x 4" D(362mm W x 616mm H x 101mm D)D O O R K I N G ,®I N C.120 Glasgow Avenue, Inglewood, California 90301 EE.UU. T el: 310-645-0023 FAX: 310-641-1586 Distribuido por:。
ACTAS P14中文说明书
图解 2: 连接测试对象
■ 首先连接行程传感到测试对象,然后连接测试主触头状态、线圈和马达电流的导线。 ■ 使用可以可靠连接的插件或电缆接线头固定到测试对象。
■ 移开所有多余的测试线,测试线也要尽可能的短,尤其是需要连接到操作线圈和马达电流测量时,选择正确 的导线截面积是很重要的。
警示
为了安全,需要使用安全香蕉插,测试线必须完全绝缘,测试过程中,有时会有几百伏
2 安全
连接和试运行ACTAS P14测试仪器前,请仔细阅读操作说明书,它包含了重要的安全提示和警告,使 用ACTAS P14时必须遵守。
2.1 引言
警告 此标识为该说明书中的危险警示,提醒使用者或第三方使用者不正当造成的潜在危险.
警示 该标识为建议使用者特别注意的标识,通过对正确操作的特别强调以防止运行过程中测试仪 器或相连接的其它装置损坏。
警告: 打开测试仪器会引起触电,因此,任何情况下都不允许打开测试仪器。
3 调试
警告
测试仪器不能用于危险的场所。
3.1 启动测试仪器
当测量仪器从一个寒冷的地方带到较热的地方时,冷凝可能导致危险状况。因此需要严格遵守接地操作。
3.2 连接保护接地
图解 1: A连接带接地的三孔电源线。为了达到这个目的,电源线的插孔必须要接
确保当前绝对没有测试输出时,被测试的设备(也就是测试对象)才可以连接或者断开。 当连接测试对象时,请认真了解一下内容: ■ 开关装置的主回路必须和母线断开,断路器极柱必须合闸和两端的安全接地,测试的时候必须移开一端的接 地。 ■ 连接驱动单元时,需要停止操作和断开电源。另外,储能原件在储能情况下必须释能(弹簧、液压或气动)
1 引言
ACTAS P14是一款 用于中、高压开关测试的系统。在测试期间,开关装置(测试对象)连接到测试系统以测 量重要的电气和机械参数,然后进行分析。 ACTAS P14是由测试仪器和标准的带用于操作和分析软件ACTAS的计算机组成的主/从系统。 两者通过串行 接口(RS232)或USB接口连接。计算机为主控制测试仪器控制测试仪器(从系统),配置好后,测试仪器来 执行测试动作。实时记录测试对象动作,同时计算机读出记录数据进行分析。 ACTAS P14共有14个模拟测量输入(8个模拟传感器和6个数字传感器)和多达66个二进制测量输入, 还有超 过10个控制输出接口。控制输出用于测试对象进行开关的操作。测试对象的动作情况通过信号实时反馈和在电脑 并进行分析. 同时,由于ACTAS P14具有高系统集成,紧凑特点和便携的ABS外壳使得该仪器适合在苛刻环境下 的运输。 除了ON/OFF开关,测试仪器本身没有可供操作的部件,所有的操作和控制都是通过标准计算机中的ACTAS软件 来进行。ACTAS用户手册会有如何使用的详细描述。当前操作说明书只有描述测试仪器本身。例如,硬件和如何 连接测试对象。
M1A3P600-PQ144PP中文资料(Actel)中文数据手册「EasyDatasheet - 矽搜」
•差分I / O标准:LVPECL,LVDS,B-LVDS,和
M-LVDS(A3P250及以上)
•I / O寄存器输入,输出,并启用路径 •支持热插拔,冷饶让I / O •可编程输出摆率
‡ † 和驱动强度
•弱上拉/ -Down
•IEEE 1149.1(JTAG)边界扫描测试
•引脚兼容横跨ProASIC3系列套餐
169
1.0 1.45
FG256 17 × 17
289
1.0 1.60
FG484 23 × 23
529
1.0 2.23
II
v1.0
芯片中文手册,看全文,戳
ProASIC3订购信息
闪存ProASIC3系列FPGA
A3P1000 _ 1
FG
G
144
I
封装引脚数
应用程序(温度范围)
空白=商业(0°C至+ 70°C环境温度下)
A3P600 = 60万系统门 A3P1000 = 1,000,000个系统门
ProASIC3器件与 ARM7
M7A3P1000 = 1,000,000个系统门
ProASIC3器件具有 Cortex-M1
M1A3P250 = 250000系统门
M1A3P400 = 400000系统门 M1A3P600 = 600000个系统门 M1A3P1000 = 百万个系统门
* 为-F速度等级目标DC和开关特性只是基于模拟. 规定-F速度等级特点是主题建立FPGA规格后更改.一些限制可能会增加,并会反映在该文档后续版本.该-F速度等 级只在商用温度范围内支持.
v1.0
III
芯片中文手册,看全文,戳
温度等级奉献
包裹
A3P600中文资料
PQ208
PQ208
PQ208
FG144, FG256, FG144, FG256, FG144, FG256,
FG484
FG484
FG484
Notes:
1. Refer to the CoreMP7 datasheet for more information. 2. AES is not available for ARM-enabled ProASIC3 devices. 3. Six chip (main) and three quadrant global networks are available for A3P060 and above. 4. For higher densities and support of additional features, refer to the ProASIC3E Flash FPGAs datasheet. 5. The M7A3P250 device does not support this package.
May 2007 © 2007 Actel Corporation
1 See the Actel website for the latest version of the datasheet.
元器件交易网
ProASIC3 Flash Family FPGAs
I/Os Per Package1
Operation up to 350 MHz
Soft ARM7™ Core Support in M7 ProASIC3 Devices
• CoreMP7Sd (with debug) and CoreMP7S (without debug)
Table 1 • ProASIC3 Product Family
A3P030中文资料
May 2007 © 2007 Actel Corporation
1 See the Actel website for the latest version of the datasheet.
元器件交易网
ProASIC3 Flash Family FPGAs
I/Os Per Package1
number.
2
Product Brief
元器件交易网
ProASIC3 Ordering Information
ProASIC3 Flash Family FPGAs
A3P1000 _ 1
FGBiblioteka G144I
Application (Temperature Range)
Blank = Commercial (0°C to +70°C) I = Industrial (–40°C to +85°C)
RAM kbits (1,024 bits)
4,608-Bit Blocks
FlashROM Bits Secure (AES) ISP2
Integrated PLL in CCCs VersaNet Globals3
I/O Banks
Maximum User I/Os
Package Pins QFN VQFP TQFP PQFP FBGA
元器件交易网
ProASIC®3 Flash Family FPGAs
with Optional Soft ARM® Support
Product Brief ®
Features and Benefits
High Capacity
• 30 k to 1 Million System Gates • Up to 144 kbits of True Dual-Port SRAM • Up to 300 User I/Os
PRIMECENTER M1 架架系统配置器和订单信息指南说明书
PRIMECENTER M1 Racks 16U/24U/42USystem configurator and order-information guide May 2017ContentsConfigurator diagramConfiguration and order process informationRack configurationsRack mounting ex factoryRack accessoriesRack consoleKVM switchesPower socket outletsUninterruptible power suppliesBackup Device FibreCAT TXF10 GbE Twinax-CablingIB SwitchIB CablingVDX 6740VDX 6740TVDX 6740T-1GVDX 6940-36QICX6430ICX6450ICX6610ICX7450ICX7750-48FICX7750-48CICX7750-26QData Sheet Smart UPSGeneral rack accessoriesChange ReportPRIMERGY ServerSystem configurator and order-information guidePRIMECENTER M1 Racks Status 2017-04-27System configurator and order-information guideSystem configurator and order-information guide PRIMECENTER M1 Racks Status 2017-04-27TWINAX-Cabling with virtual SFP+ modulesProduct number Connector DescriptionV:TWX CONNECTOR-BR FC TWX 10G connector BR Twinax Connector BrocadeV:TWX CONNECTOR CI FC TWX 10G connector CI Twinax Connector CiscoV:TWX CONNECTOR PY FC TWX 10G connector PY Twinax Connector PrimergyV:TWX CONNECTOR SP FC TWX 10G connector SBAX Twinax Connector SBAX2 und PassThru V:TWX CONNECTOR-40FC TWX 40G connector PY Twinax Connector 40GbE SBAX3V:TWX CONNECTOR-BR40FC TWX 40G connector BR Twinax Connector 40GbE BrocadeRack-specified Twinax-cable for graphical Cabling within the PRIMECENTER M1 Rack:S26361-F3873-E500SFP+ activ Twinax Cable Brocade custom2x FC TWX 10G connector BRS26361-F3989-E600SFP+ aktives Twinax Kabel kundenspez.2x FC TWX 10G connector PYS26361-F4571-E500SFP+ passive Twinax Kabel Cisco custom2x FC TWX 10G connector CIS26361-F3986-E400QSFP+ aktives Twinax Kabel kundenspez.2x FC TWX 40G connector PYS26361-F5317-E40QSFP+ aktives Twinax Kabel BR kundenspez.2x LAN TWX 40G connector BRS26361-F5317-E400QSFP+/4xSFP+ Breakout Kabel Brocade cust4x/1x LAN TWX 10/40G connector BRAdd. Twinax-cable for graphical cabling outside the PRIMECENTER M1 Rack (between racks):EBR800-TWX-1M-L SFP+ active Twinax cable BRCD 1m UPG2x FC TWX 10G connector BREBR800-TWX-3M-L SFP+ active Twinax cable BRCD 3m UPG2x FC TWX 10G connector BREBR800-TWX-5M-L SFP+ active Twinax cable BRCD 5m UPG2x FC TWX 10G connector BRIn Addition the optional configurable Twinax-cable options (also for graphical cabling in systemarchitect usable!)(to find under chapter "Hardware – Options" of the Blade system units BX900S2 and BX400S1)S26361-F3873-L501Brocade 1mS26361-F3873-L503 Brocade 3mS26361-F3873-L505 Brocade 5mS26361-F4571-L101Cisco 1mS26361-F4571-L103 Cisco 3mS26361-F4571-L105 Cisco 5mS26361-F4571-L107 Cisco 7mS26361-F4571-L110 Cisco 10mS26361-F3989-L102FJ 2mS26361-F3989-L105FJ 5mS26361-F3989-L110FJ 10mS26361-F5317-L41Brocade 40G 1mS26361-F5317-L43Brocade 40G 3mS26361-F5317-L45Brocade 40G 5mS26361-F5317-L401Brocade 1mS26361-F5317-L403Brocade 3mS26361-F5317-L405Brocade 5mSystem configurator and order-information guideSystem configurator and order-information guidePRIMECENTER M1 Racks Status 2017-04-27Mellanox IB-Cabling for EDR HCA 100GbCable- Nr.S26361-K1560-V10Intel IB Cu Cable 100Gb, l=3m, Order-number: S26361-F5549-L561 (for loose delivery of the IB cable)Intel IB Cu Cable 100Gb, l=3m, Order-number: S26361-F5549-L563 (for loose delivery of the IB cable)Additional informations about cablingMellanox IB-Cabling for FDR HCA 56GbCable- Nr.Mellanox IB-Switchl InfiniBand QSFP (connector in SA, 1x w ith E102 and 2x w ith E202)and to other -F4533-E102/E202InfiniBand Cu cable 56Gb, customized, order number: S26361-F3996-E556 (for cabling in SA)InfiniBand Cu cable 56Gb, l=1m, Order-number: S26361-F3996-L561 (for loose delivery of the IB cable)InfiniBand Cu cable 56Gb, l=3m, Order-number: S26361-F3996-L563 (for loose delivery of the IB cable)Additional informations about cablingIntel IB-Cabling for QDR HCA 40GbCable- Nr.l InfiniBand QSFP (connector in SA 1x w ith E122 and 2x w ith E222)and to other -F4475-E122/E222Intel IB Cu Cable 40Gb, l=3m, Order-number: S26361-F3996-L203 (for loose delivery of the IB cable)Intel IB FO Cable 40Gb, l=10m, Order-number: S26361-F3996-L210 (for loose delivery of the IB cable)Additional informations about cablingPRIMERGY Server Length Other Informations about IB cabling / controller releases, see the respective configuratorPRIMERGY Server Length Intel IB-SwitchOther Informations about IB cabling / controller releases, see the respective configuratorPRIMERGY Server Length Mellanox IB-SwitchOther Informations about IB cabling / controller releases, see the respective configuratorIntel OP-Cabling for Omni-Path HFI 100GbS26361-K1576-V10/V11Cable- Nr.S26361-K1576-V20/V21Intel IB Cu Cable 100Gb, l=1.5m, Order-number: S26361-F5563-L150 (for loose delivery of the IB cable)Intel IB Cu Cable 100Gb, l=2m, Order-number: : S26361-F5563-L200 (for loose delivery of the IB cable)Intel IB Cu Cable 100Gb, l=3m, Order-number: : S26361-F5563-L300 (for loose delivery of the IB cable)Additional informations about cablingOther Informations about IB cabling / controller releases, see the respective configuratorIntel OP-SwitchPRIMERGY Server LengthSystem configurator and order-information guideSystem configurator and order-information guideStatus 2017-04-27Orderable modules and cables (loose delivery):The Brocade VDX6740 has 48x SFP+ and 4x QSFP+ ports.1GbE SFP modules:S26361-F5263-L102 1000Base-SX, MMF, LC connectorS26361-F5263-L103 1000Base-LX, SMF, LC connectorS26361-F3873-L461 1000Base-T, copper, RJ45 connector10GbE SFP+ modules:S26361-F3873-L310 10GBase-SR, MMF, LC connectorS26361-F3873-L311 10GBase-LR, SMF, LC connectorS26361-F3873-L312 10GBase-ER, SMF, LC connector40GbE QSFP+ modules:S26361-F5294-L110 40GBase-SR4, MMF, MTP connectorS26361-F5294-L114 40GBase-SR4-INT, MMF, MTP connector,compatible with 10GBASE-SR, 10G breakout-capableS26361-F5317-L110 40GBase-LR4, SMF, MTP connectorD:40G-QSFP-ESR4-L 40GBase-eSR4, MMF, MTP connector8 Gbit/s FC SFP modules:S26361-F3873-L109 8Gb/s FC, MMF, LC connectorS26361-F3873-L208 8Gb/s FC, SMF, LC connector16 Gbit/s FC SFP modules:S26361-F3873-L116 16Gb/s FC, MMF, LC connectorS26361-F3873-L216 16Gb/s FC, SMF, LC connector10 GbE SFP+ cables:S26361-F3873-L501 SFP+ active twinax cable 1mS26361-F3873-L503 SFP+ active twinax cable 3mS26361-F3873-L505 SFP+ active twinax cable 5mS26361-F3873-L507 SFP+ active optical cable 7mS26361-F3873-L510 SFP+ active optical cable 10m40 GbE QSFP+ cables:S26361-F5317-L41 QSFP+ active twinax cable 1mS26361-F5317-L43 QSFP+ active twinax cable 3mS26361-F5317-L45 QSFP+ active twinax cable 5mD:40G-QSFP-QSFP-AOC-1001 QSFP+ active optical cable 10m40GbE to 4x 10GbE QSFP+ to 4x SFP+ break out cables:S26361-F5317-L401 QSFP+ to 4x SFP+ active twinax cable, 1mS26361-F5317-L403 QSFP+ to 4x SFP+ active twinax cable, 3mS26361-F5317-L405 QSFP+ to 4x SFP+ active twinax cable, 5mD:40G-QSFP-4SFP-AOC-1001 QSFP+ to 4x SFP+ active optical cable, 10moptical LC/LC cables can be used for 10GbE/8Gbit/s/16GBit/s:S26361-F3986-L500 FC Fiber-Kabel OM3, MMF, LC/LC 5mD:FCKAB-OM4-C05L-L FC-Cable OM4, MMF, 5m, LC/LCD:FCKAB-OM4-C10L-L FC-Cable OM4, MMF, 10m, LC/LCD:FCKAB-OM4-C20L-L FC-Cable OM4, MMF, 20m, LC/LCD:FCKAB-OM4-C50L-L FC-Cable OM4, MMF, 50m, LC/LCoptical MTP/MTP cables can be used for 40GbE cabling:S26361-F5294-L405 Fiber cable MTP/MTP 5m crossover, MMFS26361-F5294-L410 Fiber cable MTP/MTP 10m crossover, MMFD:FCKAB-MTP-C05-L MTP cable 5m MTP-female MTP-femaleD:FCKAB-MTP-C10-L MTP cable 10m MTP-female MTP-femaleD:FCKAB-MTP-C20-L MTP cable 20m MTP-female MTP-femaleD:FCKAB-MTP-C50-L MTP cable 50m MTP-female MTP-femaleD:FCKAB-MTP-C100-L MTP cable 100m MTP-female MTP-femaleoptical MTP/4xLC cables can be used for 40GbE to 4x10GbEor 4x 16Gbit/s FC breack-out cablingS26361-F5294-L445 Fiber cable OM4, MMF, MTP12/4xLC 5mS26361-F5294-L100 Fiber coupler OM4, MMF, LC/LCSystem configurator and order-information guideEnd of Brocade VDX6740T SwitchSystem configurator and order-information guide PRIMECENTER M1 Racks Status 2017-04-27System configurator and order-information guide PRIMECENTER M1 Racks Status 2017-04-27tusSystem configurator and order-information guidePRIMECENTER M1 Racks Status 2017-04-27 X ICX 7450 Switch ConfigurationS26361-K1572-V124S26361-K1572-V148The switch can beBrocade ICX 7450-24Brocade ICX 7450-48mounted into a Rack ex factory24x1 GbE switch, copper (RJ45),48x1 GbE switch, copper (RJ45),1x3x optional modul slots3x optional modul slotsBase software Base softwareincl. lifetime reinsurance incl. lifetime reinsuranceNo PSU, FAN, RMK included No PSU, FAN, RMK includedS26361-F4530-E11S26361-F4530-E10S26361-F2735-E111Mounting of RMK in asymmetrical Fixing or attachment of RMK in Not RMKrack incl. 1U support bracket.symm. racks wo/ support bracket.1x per systemS26361-F5317-E520newBrocade 4 post RMKFor PRIMECENTER M1 racks1x per switch1xS26361-F4530-E141Perforated panel 1Upermeable to air1x per RMK, no add. HUS26361-F1647-E302S26361-F5294-L740Mounting service for Premium software licenseinstallation ex works Optional license to enable1x per Switch premium Layer 3 featureslike routingS26361-F5294-E20up to 1x per systemPSU unit 220V, 250W outputPort side exhaust airflow1-2x per switch1-2xS26361-F5294-E749FAN unitPort side exhaust airflow1-2x per switchS26361-F3417-E600 *)CAT 6A S/STP RJ45 cables can be used for proper cabling:Copper cable CAT 6A S26361-F3417-L602: CAT 6A, RJ45 connector, 2m0-24/48x RJ45 connectors S26361-F3417-L603: CAT 6A, RJ45 connector, 3mcustomized length S26361-F3417-L605: CAT 6A, RJ45 connector, 5mup to 24/48x per switch S26361-F3417-L610: CAT 6A, RJ45 connector, 10mS26361-F3417-L615: CAT 6A, RJ45 connector, 15mS26361-F5294-E746S26361-F5294-E748S26361-F5294-E747S26361-F5294-E745Expansion module 4 ports Expansion module 4 ports Expansion module 4 ports Expansion module 1 port 0-3x4x1/10Gbase-T RJ454x100M/1GbE SFP4x1/10GbE SFP+1x40Gbase QSFP+up to 3x per Switch up to 1x per Switch up to 3x per Switch up to 3x per SwitchS26361-F3417-E600 *)Copper cable CAT 6A*) in SA only0-12x RJ45 connectors shown incustomized length cabling viewup to 4x per moduleV:TWX Connector-BR S26361-F3873-E310S26361-F5263-E102S26361-F5263-E103S26361-F5263-E161new 10GbE Twinax Brocade SFP+ for uplink ports SFP for uplink ports SFP for uplink ports SFP for uplink portsmax. 4x per module10GBase-SR SFP+ optic, 1000Base-SX SFP optic,1000Base-LX SFP optic,1000Base-T copperLC connector, MMF,LC connector, MMF LC connector, SMF RJ45 connectorup to 300 meter Optical Monitoring Capable Optical Monitoring CapableS26361-F3873-E500 *)up to 4x per module up to 4x per module up to 4x per module up to 4x per module 0-12x SFP+ active twinax cablecustomized twinax cable forfull rack setup ex factory S26361-F3986-E500 *)S26361-F3417-E600 *)cable length is selected by Fiber cable OM3,*) in SA only Copper cable CAT6Arequirement in the factory MMF, LC/LC 5m shown in RJ45 connectorscabling view customized length max. 4x per module up to 4x per module up to 4x per moduleV:TWX_Connector-BR40ST74V:TWX Connector-BR40S26361-F5294-E11040GbE Twinax Brocade ST40GbE Twinax Brocade QSFP+ for uplink portsup to 1x per QSFP+ module up to 1x per QSFP+ module40GBase-SR4 QSFP+ opticMTP connector, MMF,up to 100 meter 0-3x S26361-F5294-E150 *)S26361-F5294-E101 *)S26361-F5317-E40 *)up to 1x per QSFP+ module QSFP+ passive twinax cable QSFP+ passive twinax cable QSFP+ active twinax cablefor stacking to ICX 7450 only for stacking to ICX 7450 only customized twinax cablefor rack setup ex factory S26361-F5294-E405 *)QSFP+ to QSFP+, 0.5m QSFP+ to QSFP+, 1m QSFP+ to QSFP+, 1/3/5m MTP / MTP connectorup to 1x per QSFP+ module up to 1x per QSFP+ module up to 1x per QSFP+ module MMF, 5m, crossoverup to 1x per portSystem configurator and order-information guide PRIMECENTER M1 Racks Status 2017-04-27System configurator and order-information guidePRIMECENTER M1 Racks Status 2017-04-27Information about Smart USV in the internet see:https:///com/products/servers/primergy/rackcomp/components/usv/Pages/default.aspxSystem configurator and order-information guidePRIMECENTER M1 Racks Status 2017-04-27general rack accessoriesS26361-F4530-L250Brush Panel Kit (2pcs) PCR M1 for assembly in 42U PRIMECENTER M1 Racks at customer.S26361-F4530-L260Brush Panel Kit (1pc) Rear Door PCR M1 for assembly in 42U PRIMECENTER M1 Racks at customer.S26361-F4530-L210Tilting Protection Pull Out PCR M1 for assembly in PRIMECENTER M1 Racks at customer.S26361-F4530-L225Rack Connection Kit for joining of 2 PRIMECENTER M1 Racks at customer.S26361-F4530-L6Earthing Kit Racks PCR M1 for assembly in PRIMECENTER M1 Racks at customer.S26361-F4530-L131Dummy panel 1U plastics satin black for assembly in 19" rack S26361-F4530-L132Dummy panel 2U plastics satin black for assembly in 19" rack S26361-F2735-L10Support bracket for asymmetrical racks, max. load up to 15kg (servers up to 25kg)for compensation of shifted post in asymmetrical PRIMECENTER racks S26361-F2735-L15Support bracket for asymmetrical racks, max. load up to 35kg for compensation of shifted post in asymmetrical PRIMECENTER racks S26361-F2735-L31Support bracket for asymmetrical racks, max. load up to 50kg for compensation of shifted post in asymmetrical PRIMECENTER racks S26361-F2735-L150RMK-S Vario carrier w. L-shaped brackets easy rack mounting for 19inch rack systems in PC racks, max. load 50 kg S26361-F2735-L7Cable magmt. for 19" DC- PC- Rack S26361-F2735-L811U cable arm for RMKs with cable management arm (CMA) adapter S26361-F2735-L81U cable arm for RMKs without CMA adapter S26361-F2201-L202U cable arm for RMKs without cable management arm (CMA) adapter in PRIMECENTER M1 or 3rd party racks.S26361-F2735-L822U cable arm for RMKs with cable management arm (CMA) adapter S26361-F2735-L320RMK-PDU 2U horizontal S26361-F2735-L330RMK-PDU 3U horizontal S26361-F1609-L35Add-on base plate, 680mm deep 1U S26361-F2735-L500cage nut set, M5, t=2,5mm S26361-F2735-L510SCREW SET IO-BOX Rack MountingContent: M5X14-TORX screws, cage nuts, rosettes; each 16 pieces orderable to IO-boxes, switches and racksDetail: mounted 1U cable arm at the left sife of 19" profile open with Adobe Acrobat reader Content: 50 pieces orderable to boxes, server and racks for assembly in 19" rack (1U), with support bracket, anthracite cable management for adding a server or storage subsystem from a 3rd party rack into the PRIMECENTER rack cable arm for 1U PRIMERGY server, dragged for PRIMECENTER- and 3rd-partySystem configurator and order-information guidePRIMECENTER M1 Racks Status 2017-04-27 Changereport。
Schneider Electric 产品数据手册:ABLM1A12010 调节电源供应,100-2
T h e i n f o r m a t i o n p r o v i d e d i n t h i s d o c u m e n t a t i o n c o n t a i n s g e n e r a l d e s c r i p t i o n s a n d /o r t e c h n i c a l c h a r a c t e r i s t i c s o f t h e p e r f o r m a n c e o f t h e p r o d u c t s c o n t a i n e d h e r e i n .T h i s d o c u m e n t a t i o n i s n o t i n t e n d e d a s a s u b s t i t u t e f o r a n d i s n o t t o b e u s e d f o r d e t e r m i n i n g s u i t a b i l i t y o r r e l i a b i l i t y o f t h e s e p r o d u c t s f o r s p e c i f i c u s e r a p p l i c a t i o n s .I t i s t h e d u t y o f a n y s u c h u s e r o r i n t e g r a t o r t o p e r f o r m t h e a p p r o p r i a t e a n d c o m p l e t e r i s k a n a l y s i s , e v a l u a t i o n a n d t e s t i n g o f t h e p r o d u c t s w i t h r e s p e c t t o t h e r e l e v a n t s p e c i f i c a p p l i c a t i o n o r u s e t h e r e o f .N e i t h e r S c h n e i d e r E l e c t r i c I n d u s t r i e s S A S n o r a n y o f i t s a f f i l i a t e s o r s u b s i d i a r i e s s h a l l b e r e s p o n s i b l e o r l i a b l e f o r m i s u s e o f t h e i n f o r m a t i o n c o n t a i n e d h e r e i n .Product data sheetCharacteristicsABLM1A12010Regulated Power Supply, 100-240V AC, 12V 1A, single phase, ModularMainRange of product Modicon Power Supply Product or component typePower supplyPower supply type Regulated switch mode Variant option Modular Enclosure material PlasticNominal input voltage 100...240 V AC single phase 100...240 V AC 2 phases Input voltage limits 90...264 V AC Kw Rating 12 W Output voltage 12 V DC Power supply output current1 AComplementaryNominal network frequency 50…60 Hz Network system compatibilityTN TT ITMaximum leakage current 0.25 mA 240 V ACInput protection typeIntegrated fuse (not interchangeable) 3.15 AExternal protection (recommended) 20 A Curve B External protection (recommended) 20 A Curve C External protection (recommended) 2 A Curve B External protection (recommended) 2 A Curve C Inrush current 15 A 115 V 30 A 230 V Power factor 0.51 at 115 V AC 0.40 at 230 V AC Efficiency80 % 115 V AC 80 % 230 V AC Power dissipation in W 3 WCurrent consumption < 0.4 A 115 V AC < 0.25 A 230 V AC Turn-on time < 2 sHolding time> 10 ms 115 V AC > 60 ms 230 V AC Startup with capacitive loads 3000 µF Residual ripple< 100 mV Expected capacitor life time 10 year(s)Meantime between failure [MTBF]3000000 H at 77 °F (25 °C), full load 1000000 h at 131 °F (55 °C), 80 % loadOutput protection typeAgainst overload and short-circuits, protection technology: automatic reset Against over temperature, protection technology: manual reset Against overvoltage, protection technology: manual resetConnections - terminalsScrew connection 0.5...1.5 mm², AWG 20...AWG 16) without wire end ferrule input/outputScrew connection 0.5...1 mm², AWG 20...AWG 18) with wire end ferrule input/output Line and load regulation < 0.5 %line < 1 %loadStatus LED Output voltage 1 LED Green)Depth2.19 in (55.6 mm)Height 3.58 in (91 mm)Maximum Width0.71 in (18 mm)Net Weight0.22 lb(US) (0.101 kg)Output coupling SerialMounting support Top hat type TH35-15 rail conforming to IEC 60715Top hat type TH35-7.5 rail conforming to IEC 60715Double-profile DIN railPanel mountingEnvironmentStandards EN 62368-1EN/IEC 61010-1EN 61010-2-201EN/IEC 61204-3EN 61000-6-1EN 61000-6-2EN 61000-6-3EN 61000-6-4EN 61000-3-2EN 61000-3-3UL 62368-1UL 61010-1UL 61010-2-201CSA C22.2 No 62368-1CSA C22.2 No 61010-1CSA C22.2 No 61010-2-201Product certifications CECUL listedCUL recognizedRCMCB SchemeEACKCNEC class 2Operating altitude< 6561.68 ft (2000 m) overvoltage category III2000 m...5000 m overvoltage category IIShock resistance100 m/s² for 11 msIP degree of protection IP20Ambient air temperature for operation-13…131 °F (-25…55 °C) without current derating)131…158 °F (55…70 °C) with current derating of 2.67 % per °C)Ambient air temperature for storage-40…185 °F (-40…85 °C)Relative humidity0…95 % without condensationOvervoltage category IIElectrical shock protection class Class II without PE connectionPollution degree2Vibration resistance 3 mm 2…9 Hz)IEC 60721-3-310 m/s² 9…200 Hz)IEC 60721-3-3Electromagnetic immunity Immunity to electrostatic discharge - test level: 6 kV (contact discharge)conforming to EN/IEC 61000-4-2Immunity to electrostatic discharge - test level: 9 kV (air discharge) conforming toEN/IEC 61000-4-2Electromagnetic field immunity test 10 V/m 80 MHz...2 GHz) EN/IEC 61000-4-3Electromagnetic field immunity test 5 V/m 2...2.7 GHz) EN/IEC 61000-4-3Electromagnetic field immunity test 3 V/m 2.7...6 GHz) EN/IEC 61000-4-3Immunity to fast transients - test level: 4 kV (on input-output) conforming to EN/IEC 61000-4-4Surge immunity test - test level: 3 kV (between power supply and earth)conforming to EN/IEC 61000-4-5Surge immunity test - test level: 1.5 kV (between phases) conforming to EN/IEC61000-4-5Immunity to conducted disturbances 10 Vrms 0.15...80 MHz) EN/IEC 61000-4-6Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8Immunity to voltage dips 100 % 1 cycle) EN/IEC 61000-4-11Immunity to voltage dips 60 % 10 cycles) EN/IEC 61000-4-11Immunity to voltage dips 30 % 25 cycles) EN/IEC 61000-4-11Disturbing field emission conforming to EN 55016-2-3Limits for harmonic current emissions conforming to EN 61000-3-2Conducted disturbance emission conforming to EN 55016-1-2Conducted disturbance emission conforming to EN 55016-2-1Electromagnetic emission Conducted emissions conforming to EN 61000-6-3Radiated emissions conforming to EN 61000-6-4Dielectric strength3000 V AC input/outputOrdering and shipping detailsCategory22525 - ABL8 AND ABL7 POWER SUPPLIEDiscount Schedule CP12GTIN00785901699200Nbr. of units in pkg.1Package weight(Lbs)1 lb(US) (0.45 kg)Returnability YesOffer SustainabilitySustainable offer status Green Premium productCalifornia proposition 65WARNING: This product can expose you to chemicals including: Lead andlead compounds, which is known to the State of California to cause cancerand birth defects or other reproductive harm. For more information go toREACh Regulation REACh DeclarationEU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)EU RoHSDeclarationMercury free YesRoHS exemption information YesChina RoHS Regulation China RoHS DeclarationEnvironmental Disclosure Product Environmental ProfileCircularity Profile End Of Life InformationWEEE The product must be disposed on European Union markets following specificwaste collection and never end up in rubbish bins.Dimensions DrawingsElectrical Safety●If the unit is use in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.●For means of disconnection a switch or circuit breaker, located near the product, must be included in the installation. A marking asdisconnecting device for the product is required.●The device has an internal fuse. The unit is tested and approved with branch circuit protective device up to 20A. This circuit breaker canbe used as disconnecting device.●The power supply is only suitable for audio, video, information, communication, industrial and control equipment.DimensionsSide and Rear ViewConnections and SchemaConnections and SchemaSeries Connection(1) :V out1(2) :V out2(3) : 2 x Diode, V RRM > 2 x V out1/2, I F > 2 x I nom1/2(4) :V Load = 2 x V out (5) :LoadConnections and Schema(1) :AmbientPerformance CurvesPerformance CurveX :Ambient Temperature (ºC)Y :Percentage of Max Load (%)1 :Mounting A & B, altitude 2000M 2 :Mounting A & B, altitude 5000MMounting and ClearanceMountingMounting Position AMounting Position BIncorrect Mounting。
凯特拉克筋膜抑制器产品说明书
Item No. EC1B/EC1S/EC1WInstallation GuideWebsite: Tel: 1-855-421-2808What is Not Covered?Our limited warranty does not cover any problem that is caused by:1. Conditions, malfunctions or damage not resulting from defects in material or workmanship.2. Conditions, malfunctions or damage resulting from normal wear and tear, improper installation, improper maintenance, misuse, abuse, negligence, accident or alteration.3. Accessories, connected materials and products, or related products not manufactured by FlexiSpot.4. Conditions, malfunctions or damage resulting from failure to follow the instructions and guidelines relating to the product's intended use.Our limited warranty is void if a product is returned with removed, damaged or tampered labels or any alterations (including removal of any component or external cover).How to File a Claim?In order to receive the benefit of our limited warranty, you need to process your claim in compliance with the terms of this limited warranty and follow proper return procedure. Torequestwarrantyservice,***********************************************************or toll free at 855-421-2808. You will need to provide the sales receipt or other evidence of the date and place of purchase for your FlexiSpot product.Implied Warranties and Limitation of DamagesEXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ALL IMPLIED WARRANTIES (INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE) SHALL BE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY, AND SHALL NOT BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR FLEXISPOT CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS OR REVENUE, RESULTING FROM ANY BREACH OF EXPRESS OR IMPLIED WARRANTY OR CONDITION, OR UNDER ANY OTHER LEGAL THEORY, EVEN IF HAS BEEN FLEXISPOT ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Some jurisdictions do not allow limitations on the duration of an implied warranty or the exclusion or limitation of special,indirect, incidental or consequential damages, so the above limitations or exclusions may not apply to you.Governing LawThis Warranty shall be governed by the laws of the State of California, USA, without giving effect to any conflict of laws principles that may provide the application of the law of another jurisdiction.How State Law AppliesThis Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.Accessory PackageSpecificationsStep 10102Figures shown are for reference only. Please contact customer service if there are any accessory or tools missing.Attaching the desk feet (1) to the legs (2&3) using 8 M6x16mm bolts (A). Tighten with 5x5 hex key (C).Step 2Turn the legs (2) down like ①. Attach the beam to the legs using M8x50mm bolts (B) and tighten with 5x5 hex key (C). Then attach the desk leg (3) like ②.Parts Included Diagram of Components 11111NO.Parts Qty NO.Parts Qty NO.Parts Qty 2345678910212114Max. Weight Capacity 154 Ibs (70 kg)Max. Speed 1"/s Input Voltage 100 - 240 V Min. Height 28" (710 mm)Max. Height 47.6" (1210 mm)32º - 104º FDuty Cycle10% (Working 2 minutes then stop 18 minutes) Working TemperatureDesktop size 39.3" - 63" (1000 - 1600 mm) in widthand 19.7" - 31.5" (500 - 800 mm) in depth A x12M6X16mm5x5Cx1Ex12.5x2.5Bx4M8X50mmDx14ST4.2X20mmFx2M4X6mm x1G Desk footDesk legDesk legBeamTransmissionrodBracketAdapterPower cordBaffleC5x5Ax8C42B TightenLoosenStretchCI n s t a l l b e a m (4)12BC3x4B5x5CCable tieI n s t a l l d e s k f e e t (1)03Step 4Attach the transmission rob to the desk legs (2&3). Attach leg (2) first as shown on picture ①, then attach the other one (3) as shown on picture ②. Tighten with 2.5x2.5 hex key (D).Warning:To ensure the motor work rightly, please make sure rotate less than 1/3 circle as shown in Figure (2).Attach the bracket (6) to the desk legs (2&3) using M6x16mm bolts (A). Tighten with 5x5 hex key (C).04Step 3Step 5Place the worksurface and attach it to the bracket (6) using ST4.2x30mm screws and tighten with drill.Attach the baffle to the beam using M4x6mm bolts (E) and tighten with 2.5x2.5 hex key (D).Step 6Connect the cables to the adapter as shown on the picture.2.5x2.5D5LoosenD2321GI n s t a l l t r a n s m i s s i o n r o d (5)TightenInsertTightenRotary insertC5x5Ax4I n s t a l l b r a c k e t (6)Fx11Install the control box and handsetUnder 7.9" (200 mm) to the both edgesEx2D2.5x2.58EDThe cable tie can be used to fasten the cables to the desktop.6CA 230506●●▲▼UP Button, used to lift the desk surface DOWN Button, used to lower the desk surfaceDOWN ButtonUP ButtonHeight adjusting functionPress the UP button or DOWN button to lift or lower the height of desk surface.This list is used for checking and solving common faults and errors. Please contact the manufacturer if problem you encounter is not on the list below.FaultsNo response when you pressing and holding DOWN buttonOverworked beyond duty cycle: Max 2 min on/18 min offCan not lift from the Bottom Solution1. Check all cables are connected well.2. Contact the distributor or the manufacturer.1. Keep the power on and stop working for 30 minutes 2. Contact the distributor or the manufacturer.1. Check if the loading weights more than 154 lbs.2. Contact the distributor or the manufacturer.FlexiSpot Limited WarrantyThis limited warranty offered by FlexiSpot covers defects in material or workmanship in newFlexiSpot products. This warranty extends to the original purchaser only and is non-transferable. Only consumers purchasing FlexiSpot products from authorized FlexiSpot retailers or resellers may benefit from our limited warranty.What is Covered?The FlexiSpot limited warranty covers our products against defects in material or workmanship as follows:·FlexiSpot Height Adjustable Desk FramesAll height-adjustable desks purchased on or after October 5, 2016 include a 5-year warranty for the frame, and a 3-year warranty for the motor, controller and switch, electronics and other mechanisms.·FlexiSpot Sit-Stand Desktop WorkstationsAll standing desks purchased on or after October 5, 2016 include a 5-year warranty for the frame, medium-fiber desktop and mechanisms.·FlexiSpot Desk BikesAll desk bikes purchased on or after October 5, 2016 include a 3-year warranty for the frame, anda 1-year warranty for the electronics and other mechanisms.·FlexiSpot Mini SteppersAll desk bikes purchased on or after October 5, 2016 include a 1-year warranty for the frame, and other mechanisms.·AccessoriesAll monitor mounts purchased on or after October 5, 2016 include a 5-year warranty for the arms, 3-year warranty for gas spring system and mechanisms.What are your Remedies?FlexiSpot will replace at no charge to the consumer the defective parts only or, at FlexiSpot's option, replace any product or part of the product that is defective because of improper workmanship and/or material, under normal installation, use, service and maintenance. IfFlexiSpot is unable to provide a replacement and repair is not practical or cannot be completed in a timely fashion, FlexiSpot may elect to refund the purchase price in exchange for the return of the product. In the rare event that your FlexiSpot product is defective, we will provide you with a replacement item shipped at no cost to you within the continental United States. The shipping method for replacement products is FedEx Ground, but expedited shipping is available if you choose to pay the additional expense. In addition, you will need to pay the shipping costs if any products need to be shipped to you at an address outside the continental United States.REPAIR OR REPLACEMENT (OR, IN LIMITED CIRCUMSTANCES, REFUND OF THEPURCHASE PRICE) AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE PURCHASER. NEITHER ASSUMES NOR AUTHORIZES ANY PERSON FLEXISPOT TO CREATE FOR IT ANY OTHER OBLIGATION OR LIABILITY IN CONNECTION WITH THIS PRODUCT.·Power supply: AC100 - 240 V, frequency 50/60HZ;·Working environment: 32º - 104º F ;·Before cleaning, you have to unplug the power supply cable. Clean with a slightly damp cloth to wipe away the surface dust. Keep all electrical components away from liquids. Do not damage the connection line and keep the plug in a safe position.·Inside the control box, there are electronic components, metal parts, plastic parts, wires and so on. They should be disposed in accordance with the local laws and regulations. They cannot be disposed as household waste.·Before using the product, please make sure the product has been installed correctly.·Before starting use of the product, please read the instructions to fully understand all the product's functions and settings.·Keep children away from electric height-adjustable desks, control units and handsets.Manufacturer is not responsible of any damages that result from children's unpredictable behaviour.·Slight noise caused by the multi wedge belt or brake system will not impact the use of this product.·Do not use corrosive or abrasive materials to clean this product and please dispose of cleaning solutions in an environmentally friendly manner.·Understand the risks associated with using this product. Children or those with cognitive impairment should not use this product without supervision.·If the power supply cord is damaged or broken, it must be replaced by the manufacturer or a relevant specialist to avoid any injuries.·Please operate in a clean and safe environment. For example, do not left around your tools. And always be careful to deal with packaging materials, in order to avoid any kinds of possible danger. Potential chocking risk exists when children play with plastic bags!·If necessary, retain the original package for future transportation.Handset。
ELKM1 PC-SPIM 电源线接口模块说明书
Model:ELKM1PCSPIM Powerline Interface Module ELKM1 Data Bus Installation Guide and Owner’s Manual©2010 ELK Products Inc. All Rights Reserved.PO Box 100 Hildebran, NC 28637 P: 800-797-9355 FUNCTIONThe ELKM1 PCSPIM is a specialPowerline Interface Module containinga built-in M1XSP Serial Port chip.This all-in-one device makes it easy topermanently connect the ELK M1Control to a UPB network. Simplylocate a convenient unused AC PowerOutlet, connect a cable from the M1data bus to the four (4) terminals onthe ELKM1 PCSPIM, and perform anM1 data bus enrollment. The long distance capability of the M1 data bus makes it possible to locate the ELKM1 PCSPIM virtually anywhere, without a lot of complex or ugly cabling or connections. UPB utilizes the AC wiring circuit for transmission, without new or additional wiring, and without radio frequency signals. Note: The ELKM1 PCSPIM will not work with UPStart configuration software.IMPORTANT SAFETY INSTRUCTIONSWhen using electrical products, basic safety precautions should always be followed, including the following:1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS.2. Keep away from water. If the product is exposed to wateror other liquid, turn off the circuit breaker and unplug theproduct immediately.3. Never use products that have been dropped or damaged.4. Do not use this product outdoors.5. Do not use this product for other than its intended purpose.6. To avoid any risk of fire, burns, personal injury or electricshock, install this product out of the reach of small children.7. Do not cover product with any material when in use.8. This product uses grounded plugs and sockets to reducerisk of electric shock. These plugs and sockets fit only one way. If they do not fit, consult an electrician.SAVE THESE INSTRUCTIONS.INSTALLATIONThis device is designed for indoor use only. Follow these steps to connect the ELKM1 PCSPIM module to the ELK M1 Control.1. Using one of the diagrams on the right, connect the M1RS485 Data bus to the four (4) terminals on the bottom of the ELKM1 PCSPIM. Observe polarity and color codesfrom the diagrams.2. Plug ELKM1 PCSPIM into any grounded wall outlet. TheStatus LED should start blinking and then stay solid blue.Connecting to M1 Control using a single homerun cable.M1 application using two (2) data bus homerun cablesConnecting devices on an ELK-M1DBH Data Bus Hub An ELK-M1DBH Data Bus Hub (Optional) Can be used to connect data bus devices using Cat5/6 cables. Devices appear to be in daisy chain because 1 wire pair returns the data bus back where it’s used to feed next device OR gets terminated by special RJ45 Plug. Only 6 of the 8 total conductors are used.CONFIGURATION1. From M1 Keypad Programming (or ElkRP Software)perform a Data Bus Enrollment. Upon successful enrollment, the ELKM1 PCSPIM will show up as: SerialPExpdr T5 (M1XSP) located at Addr=07. This address is factory set and cannot be changed. If another M1XSP is installed on the M1 and assigned to Address #7 it will need to be changed and re-enrolled. 2. Using ElkRP Software, select the “Globals” Menu and tab“G29-G42 (Special)”. Locate and program the UPB Lighting Network Addr (1-255) to match the address chosen for the UPB network being configured.3. Make certain to program the format for each ElkM1Lighting device as “Serial Expander”.UPStart ConfigurationPCS developed free software (UPStart) and a PowerlineInterface Module PIM-R (9-pin serial) or a PIM-U (USB serial), for computer setup and programming of a UPB network. These PIM’s can be carried with the technician’s PC and used on future jobs. Please note that the ELKM1 PCSPIM cannot be used for the PC setup programming, it can only be used with the ElkM1. The UPStart User’s Guide (available on the PulseWorx web site: ) explains how to configure your system using the UPStart.Follow the steps described below to configure ELKM1 PCSPIM:SETUP ModeWhen configuring a UPB system and specifically the ELKM1 PCSPIM it will be necessary to place it into SETUP mode. To do this, press the Program Button 5 times rapidly. The Status LED will continuously blink Blue while the device is in SETUP mode. To exit SETUP mode, press the Program Button once or wait five minutes for it to time out.Step 1: Add the ELKM1 PCSPIM to the UPB NetworkSelect the Device ÆAdd menu item in the UPStart Setup Software. Provided the ELKM1 PCSPIM is in the Setup Mode UPStart should find it and produce a screen allowing you to assign it a name and choose what room it is located in.Step 2: Start ELKM1 PCSPIM ConfigurationDouble-click on the ELKM1 PCSPIM icon to begin configuration. Select the Advanced tab to set the receive sensitivity.The ELKM1 PCSPIM has an adjustment for UPB receive sensitivity. The factory default for this setting is “High”. If the ELKM1 PCSPIM is used in severe powerline noise, you may find that it operates better in the “Low” receive sensitivity setting.To adjust the receive sensitivity press the “Advanced” button on the UPB Interface Setup dialog. Select the desired receivesensitivity and press the “OK” button.Step 3: Program the ELKM1 PCSPIMOnce the desired configuration is completed, press the Program Device button to program the information into the ELKM1 PCSPIM.FACTORY DEFAULTING (if ever necessary)In addition to Setup Mode the push-button on the front of the case can be used to restore the device to factory default settings. To set the factory defaults first press the pushbutton 5 times rapidly. The Status LED will blink blue. Now press the pushbutton 10 times. The Status LED will blink red. Finally, press the pushbutton 2 times. The Status LED will stop blinking. The device is now restored to the following factory default settings:Network ID: 255 Unit ID:45 Network Password:1234OPERATIONOnce installed and configured your ELKM1 PCSPIM will operate without further user intervention. All programmed data is protected by nonvolatile memory and can only be changed or deleted by reprogramming, regardless of power outage durations.Status LED IndicationsThe PIM-E contains two bi-color (blue/red) Status LEDS that give a visual indication of what UPB information is currently on the powerline and communication with the M1 Bus. UPB STATUSBlue: No UPB SignalMagenta: Received a UPB Message Red: Transmitted a UPB MessageM1BUS STATUSPeriodic Slow Blink: Normal Communication with M1 Fast Flicker: Command sent or received by M1 No Blink/Off:Communication lost with M1LIMITED WARRANTYManufacturer warrants this product, if used in accordance with all applicable instructions, to be free from original defects in materials and workmanship for a period of five years from the date of purchase. Refer to the warranty information on the PulseWorx website () for exact details.These products may be covered under one or more of the following U.S. patents: 6,734,784; 6,784,790; 7,265,654; 7,688,183. U.S. and foreign patents may be pending. PCS, PulseWorx, UPB are registered trademarks and PulseWorxRF are trademarks of Powerline Control Systems, Inc. Made and printed in the U.S.A. 08/2010.Manufactured and Designed by Powerline Control Systems, Inc. for Elk Products, Inc.。
中文说明书 GRP600-1600ME
6. 燃烧器调节 ................................................................................................................ 19 6.1. 调节杆的基本位置.......................................................................................... 19 6.2. 燃油操作 ........................................................................................................ 20 6.3. 燃气操作 ........................................................................................................ 20 6.4. 伺服马达 ........................................................................................................ 21 6.6. 燃烧头调节 .................................................................................................... 22 6.7. 点火电极设置................................................................................................. 25 6.8. 调节凸轮 ........................................................................................................ 26 6.9. 调节杆............................................................................................................ 27 6.10. 燃气压力开关................................................................................................. 28 6.11. 空气压力开关................................................................................................. 29 6.12. 进油恒温器 .................................................................................................... 30 6.13. 喷嘴选型表 .................................................................................................... 31
Actaris Neptune Type S 流量计操作和维护手册说明书
TYPE S FLOWMETERS
INSTALLATION & OPERATION
For correct installation of Type S Flowmeters, the experience of Actaris Neptune is always available for your assistance. Do not hesitate to call the nearest Actaris Neptune authorized distributor.
MATERIALS OF CONSTRUCTION • Main Case: Bronze (ASTM B145 Alloy 844) Other metal components • Nutating Disk: Glass Phenolic Laminate
(Ryton or equivalent) • Diaphragm and Shafts: 304 SS • Gaskets: Viton “A”, Main Case Gaskets are Klingersil C4401
Piping • Coupling sets are provior ease in installation and removal during start-up system flushing.
爱琳曼电器产品说明书
Eaton 187365Eaton Moeller series xEffect - FRCmM Type F RCCB. Residual current circuit breaker (RCCB), 16A, 2p, 30mA, type G/FGeneral specificationsEaton Moeller series xEffect - FRCmM Type F RCCB187365401508182423680 mm 76 mm 35 mm 0.187 kg RoHS conformIEC/EN 62423 EN45545-2 IEC 61373 IEC/EN 61008FRCMM-16/2/003-G/FProduct NameCatalog Number EANProduct Length/Depth Product Height Product Width Product Weight Compliances Certifications Model CodeTwo-pole10 ms delayed16 A10 kA with back-up fuse 30 mAPulse-current sensitive3 kA (8/20 μs) surge-proof 240 V AC240 V440 V4 kV0.03 A0.03 A50 Hz / 60 Hz63 A (max. admissible back-up fuse)Other500 A16 A gG/gL10 kA3 kA184 V AC - 250 V AC2Frequency mix (10 Hz, 50 Hz, 1000 Hz) enhanced sensitivity 4000 operationsApplicationNumber of polesTripping timeAmperage RatingRated short-circuit strength Fault current rating Sensitivity typeImpulse withstand current Type Voltage rating (IEC/EN 60947-2)Rated operational voltage (Ue) - maxRated insulation voltage (Ui)Rated impulse withstand voltage (Uimp) Rated fault current - minRated fault current - maxFrequency ratingShort-circuit ratingLeakage current typeRated residual making and breaking capacity Admissible back-up fuse overload - max Rated short-time withstand current (Icw) Surge current capacityTest circuit rangePollution degreeRadiation resistanceLifespan, electricalSwitchgear for industrial and advanced commercial applicationsxEffect - Switchgear for industrial and advanced commercial applicationsCurrent test marks as per inscriptionMaximum operating temperature is 55 °C: Starting at 40 °C, the max. permissible continuous current decreases by 3% for every 1 °C45 mm235 mm (2 SU)70.5 mmDIN railQuick attachment with 2 latch positions for DIN-rail IEC/EN 60715As requiredIP20, IP40 with suitable enclosureIP20White / blueTwin-purpose terminals1.5 mm² - 35 mm²1.5 mm²35 mm²16 mm² (2x)1.5 mm²16 mm²M5 (with cross-recessed screw as defined in EN ISO 4757-Z2, PZ2)16 A1 W2 W0 W0 W-25 °C40 °CMeets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.FrameWidth in number of modular spacingsBuilt-in width (number of units)Built-in depthMounting MethodMounting positionDegree of protectionStatus indicationTerminals (top and bottom)Terminal capacity (solid wire)Connectable conductor cross section (solid-core) - min Connectable conductor cross section (solid-core) - max Terminal capacity (stranded cable)Connectable conductor cross section (multi-wired) - min Connectable conductor cross section (multi-wired) - max Terminal capacity (cable)Rated operational current for specified heat dissipation (In) Heat dissipation per pole, current-dependentEquipment heat dissipation, current-dependentStatic heat dissipation, non-current-dependentHeat dissipation capacityAmbient operating temperature - minAmbient operating temperature - max10.2.2 Corrosion resistance10.2.3.1 Verification of thermal stability of enclosures10.2.3.2 Verification of resistance of insulating materials to normal heat10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects10.2.4 Resistance to ultra-violet (UV) radiation10.2.5 Lifting10.2.6 Mechanical impact10.2.7 InscriptionsFinger and hand touch safe, DGUV VS3, EN 502742 Nm - 2.4 NmRed / green0.8 mm - 2 mm20000 operations-35 °C60 °C25-55 °C / 90-95% relative humidity according to IEC 60068-2Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Meets the product standard's requirements.Does not apply, since the entire switchgear needs to be evaluated.Does not apply, since the entire switchgear needs to be evaluated.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.Is the panel builder's responsibility.The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.Is the panel builder's responsibility. The specifications for the switchgear must be observed.Is the panel builder's responsibility. The specifications for the switchgear must be observed.The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.Terminal protectionTightening torqueContact position indicator colorBusbar material thicknessLifespan, mechanicalPermitted storage and transport temperature - min Permitted storage and transport temperature - max Climatic proofing 10.3 Degree of protection of assemblies10.4 Clearances and creepage distances10.5 Protection against electric shock10.6 Incorporation of switching devices and components 10.7 Internal electrical circuits and connections10.8 Connections for external conductors10.9.2 Power-frequency electric strength10.9.3 Impulse withstand voltage10.9.4 Testing of enclosures made of insulating material 10.10 Temperature rise10.11 Short-circuit rating10.12 Electromagnetic compatibility10.13 Mechanical functionFeatures Application notesEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All rights reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaAdditional equipment possible Residual current circuit breakerInterlocking deviceShort-time delayed trippingResidual current circuit breakers Type G/F (�VE E 8601) FRCmM eaton-rcd-application-guide-br019003en-en-us.pdfeaton-pdd-railrolling-stock-brochure-br011002en-en-us.pdfeaton-xeffect-frcmm-rccb-catalog-ca003018en-en-us.pdfDA-DC-03_FRCmeaton-circuit-breaker-xeffect-frcmm-na-rccb-dimensions.eps Mas_frcmmDA-CE-ETN.FRCMM-16_2_003-G_Featon-187365-3d-model.stpeaton-187365-drawing.dwgeaton-xeffect-frcmm-rccb-wiring-diagram.jpgFitted with: Functions Special featuresUsed with Brochures Catalogues Certification reports DrawingseCAD model mCAD model Wiring diagramsFRCmMResidual current circuit breakersType G/F (ÖVE E 8601)。
M1A3P400-FFGG144中文资料(Actel)中文数据手册「EasyDatasheet - 矽搜」
* 为-F速度等级目标DC和开关特性只是基于模拟. 规定-F速度等级特点是主题建立FPGA规格后更改.一些限制可能会增加,并会反映在该文档后续版本.该-F速度等 级只在商用温度范围内支持.
v1.0
III
芯片中文手册,看全文,戳
温度等级奉献
包裹
A3P015 A3P030
ARM7设 备
在零件号"G". 6. M1A3P250设备不支持FG256或QN132包.
表 1-1•
ProASIC3 FPGA包装规格尺寸
包裹
QN68
长 ×宽
8×8
(毫米 \毫米)
标称面产品
64
(mm 2)
间距( mm)
0.4
高度( mm)
0.90
QN132 8×8
64
0.5 0.75
VQ100 14 × 14
• 单芯片解决方案
• 防护留编程设计时已关闭
高性能
•350 MHz系统性能
•3.3 V,66 MHz64位PCI
†
在系统编程( ISP)和安全性
•安全ISP使用片上128位高级加密
标准(AES)解密(除ARM功能ProASIC
通过JTAG器件)(IEEE 1532兼容)
†
• FlashLock ® 以安全FPGA内容
A3P600 = 60万系统门 A3P1000 = 1,000,000个系统门
ProASIC3器件与 ARM7
M7A3P1000 = 1,000,000个系统门
ProASIC3器件具有 Cortex-M1
M1A3P250 = 250000系统门
M1A3P400 = 400000系统门 M1A3P600 = 600000个系统门 M1A3P1000 = 百万个系统门
A3P250中文资料
PQ208
PQ208
PQ208
FG144, FG256, FG144, FG256, FG144, FG256,
FG484
FG484
FG484
Notes:
1. Refer to the CoreMP7 datasheet for more information. 2. AES is not available for ARM-enabled ProASIC3 devices. 3. Six chip (main) and three quadrant global networks are available for A3P060 and above. 4. For higher densities and support of additional features, refer to the ProASIC3E Flash FPGAs datasheet. 5. The M7A3P250 device does not support this package.
36 8 1k Yes 1 18 4 157
QN1325 VQ100
PQ208 FG144, FG2565
400 k 9,216
54 12 1k Yes 1 18 4 194
600 k 13,824
108 24 1k Yes 1 18 4 235
1M 24,576
144 32 1k Yes 1 18 4 300
2.5 V / 1.8 V / 1.5 V, 3.3 V PCI / 3.3 V PCI-X (except A3P030), and LVCMOS 2.5 V / 5.0 V Input • Differential I/O Standards: LVPECL, LVDS, BLVDS, and M-LVDS (A3P250 and above) • I/O Registers on Input, Output, and Enable Paths • Hot-Swappable and Cold Sparing I/Os (A3P030 only) • Programmable Output Slew Rate (except A3P030) and Drive Strength • Weak Pull-Up/Down • IEEE 1149.1 (JTAG) Boundary Scan Test • Pin-Compatible Packages Across the ProASIC3 Family
M1A3P250-VQ144中文资料(Actel)中文数据手册「EasyDatasheet - 矽搜」
速度等级
FG =细间距球栅阵列(1.0 mm间距)
F =比标准慢20%*
空白=标准 比标准快1 = 15%
比标准快2 = 25%
ProAS IC 3器 件
= A3P015系统15000门 A3P030 = 30,000个系统门 A3P060 = 60,000个系统门
A3P125 = 125000个系统门 A3P250 = 25万系统门 A3P400 = 40万系统门
1 - ProASIC3器件系列简介
概述
ProASIC3中,Actel以Flash FPGA第三代家族,提供性能,密度和
超出ProASIC功能
PLUS® 家人.非易失性闪存技术使ProASIC3
设备是安全,低功耗,单芯片解决方案,上电即行(LAPU)优势.ProASIC3再编程,提供时间将
产品推向市场好处在一个ASIC级单位成本.
I =工业(
–40°C至+ 85°C环境温度)
PP =预生产
ES =工程样品(室温仅)
无铅封装
空白=标准包装 G =符合RoHS标准(绿色)包装
封装类型
零件号
QN =四方扁平封装无引线(0.6至0.5mm节距)
VQ =非常薄型四方扁平封装(0.5 mm间距)
TQ =薄型四方扁平封装(0.5 mm间距) PQ =塑料四方扁平封装(0.5 mm间距)
169
1.0 1.45
FG256 17 × 17
289
1.0 1.60
FG484 23 × 23
529
1.0 2.23
II
v1.0
芯片中文手册,看全文,戳
ProASIC3订购信息
闪存ProASIC3系列FPGA
【优质】猎豹仪表使用说明-word范文模板 (6页)
本文部分内容来自网络整理,本司不为其真实性负责,如有异议或侵权请及时联系,本司将立即删除!== 本文为word格式,下载后可方便编辑和修改! ==猎豹仪表使用说明篇一:易配通使用说明书new目录一、易配通的概述 .................................................................. . (2)1.1易配通概念 .................................................................. ....................................................... 2 1.2易配通产品的分类 .................................................................. . (2)1.2.1在线版 .................................................................. .................................................... 2 1.2.2离线版(暂不提供) ................................................................ .............................. 2 1.3易配通的特点 .................................................................. (2)1.3.1配件数据上的特点 .................................................................. ................................ 2 1.3.2系统上的区别 .................................................................. . (3)二、汽配常识................................................................... .. (3)2.1常见的汽车品牌商标的介绍 .................................................................. ........................... 3 2.2汽车配件结构介绍 .................................................................. ........................................... 6 三、易配通的使用介绍 .................................................................. .. (7)3.1登陆 .................................................................. . (7)3.1.1系统登陆 .................................................................. ................................................ 9 3.3操作说明 .................................................................. (10)3.3.1定型查询(vin,公告号定型) ................................................................. .......... 10 3.3.1.1类别查询 .................................................................. ... 错误!未定义书签。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
0.5 1.00
TQ144 20 × 20
400
0.5 1.40
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
151
34
154
35
154
35
97
25
97
25
97
25
178
38
177
43
177
44
194
38
235
60
300
74
对位置
PQ208 28 × 28
784
0.5 3.40
FG144 13 × 13
•1.5 V,1.8 V,2.5 V和3.3 V混合电压操作
•插槽可选I / O电压,高达每片4组
•单端I / O标准:LVTTL,LVCMOS 3.3 V / 2.5 V / 1.8 V / 1.5 V, 3.3 V PCI / 3.3 V PCI-X
† 和LVCMOS
2.5 V / 5.0 V输入
单端I/ O
单端I/ O
单端I/ O
差分 I / O对
差分 I / O对
差分 I / O对
差分 I / O对
包裹
QN68
49
–
–
–
–
–
QN132
–
81
80
84
87
19
VQ100
–
77
71
71
68
13
TQ144
–
–
91
100
–
–
PQ208
–
–
–
133
151
34
FG144
–
–
96
97
97
24
FG256
–
PQ208 FG144/256/
484
PQ208 FG144/256/
484
手册.
†和A3P015 A3P030设备不支持此功能.
‡只有和A3P015器件A3P030支持.
February 2008
I
© 2008 Actel Corporation
芯片中文手册,看全文,戳
I / O每包
2,C =商用温度范围:0°C至70°C环境温度 3. I =工业级温度范围:-40°C至85°C环境温度
以ProASIC3器件做出参考也适用于ARM功能ProASIC3器件.该ARM功能部件号开始使用M7(CoreMP7)和M1(Cortex-M1 ).
IV
v1.0
芯片中文手册,看全文,戳
速度等级
FG =细间距球栅阵列(1.0 mm间距)
F =比标准慢20%*
空白=标准 比标准快1 = 15%
比标准快2 = 25%
ProAS IC 3器 件
= A3P015系统15000门 A3P030 = 30,000个系统门 A3P060 = 60,000个系统门
A3P125 = 125000个系统门 A3P250 = 25万系统门 A3P400 = 40万系统门
QN132 5 VQ100
PQ208
PQ208
FG144/256 5 FG144/256/
484
A3P600
M1A3P600 600 k – 13,824 108 24 1k Yes 1 18 4 235
A3P1000 M7A3P1000 M1A3P1000
1M –
24,576 144 32 1k Yes 1 18 4 300
芯片中文手册,看全文,戳
v1.0
闪存ProASIC3系列FPGA
®
通过可选软ARM
® 支撑
特点和优点
高容量
•15 K至1M系统门
•高达144千比特真双端口SRAM
•多达300用户I / O
编 程 Flash技 术
• 130纳米,7层金属(6铜),基于闪存CMOS工艺
• 上电即行(LAPU)0级支持
低电量
•核心电压低功耗
•支持1.5 V-只有系统
•低阻抗闪光灯开关
高性能路由层次
•分段,分层路由和时钟结构
高级I / O
•700 MbpsDDR,LVDS,有能力I / O(A3P250及以上)
ProAS IC3产 品 系 列
ProAS IC3器 件
ARM7设 备
1
Cortex-M1设 备
1
A3P015 A3P030
Cortex-M1设 备
QN68
C, I
–
QN132
–
C, I
VQ100
–
C, I
TQ144
–
–
PQ208
–
–
FG144
–
–
FG256
–
–
FG484
–
–
注意事项:
1. C =商业级温度范围:0°C至70°C环境温度 2. I =工业级温度范围:-40°C至85°C环境温度
A3P060
– C, I C, I C, I – C, I – –
这些功能使设计人员能够创建利用现有ASIC或FPGA设计流程和工具高密度系统.
ProASIC3器件提供1千比特芯片,可重编程,非易失性FlashROM存储以及 基于综合锁相环(PLL)时钟调节电路.在和A3P015 A3P030器件没有PLL或RAM支持. ProASIC3器件具有高达100万系统门,具有真正双端口SRAM高达 144千比特支持和多达300个用户I / O操作.
169
1.0 1.45
FG256 17 × 17
289
1.0 1.60
FG484 23 × 23
529
1.0 2.23
II
v1.0
芯片中文手册,看全文,戳
ProASIC3订购信息
闪存ProASIC3系列FPGA
A3P1000 _ 1
FG
G
144
I
封装引脚数
应用程序(温度范围)
空白=商业(0°C至+ 70°C环境温度下)
•差分I / O标准:LVPECL,LVDS,B-LVDS,和
M-LVDS(A3P250及以上)
•I / O寄存器输入,输出,并启用路径 •支持热插拔,冷饶让I / O •可编程输出摆率
‡ † 和驱动强度
•弱上拉/ -Down
•IEEE 1149.1(JTAG)边界扫描测试
•引脚兼容横跨ProASIC3系列套餐
ProASIC3器件支持ARM7软IP核和Cortex-M1设备. ARM设备有开头M7A3P(CoreMP7)和M1A3P( Cortex-M1)和不支持AES解密Actel订购数量.
闪存优点
降低购置成本
优点设计师超出低单位成本,性能和易用性.不比 基于SRAMFPGA,以Flash为基础ProASIC3器件允许所有功能是住在电;没有外部引导PROM是必需.上 电路板安全机制防止访问所有节目安排信息并启用FPGA逻辑安全远程更新.设计人员 可以进行安全远程在系统编程,以支持未来设计迭代和现场升级与信心,有价值知识产 权(IP)不能被复制或受到威胁.安全ISP可以使用行业标准AES算法来执行. ProASIC3系 列器件结构减轻需要在更高用户容量ASIC移植.这使得ProASIC3系列具有成本效益ASIC替代 解决方案,尤其是在消费类,网络/通信,计算,和航空电子市场应用程序.
A3P1000 M7A3P1000 M1A3P1000
– – – – C, I C, I C, I C, I
速度等级和温度等级矩阵
温度等级
C2 I3
–F 1
Std.
–1
–2
✓
✓
✓
✓
–
✓
✓
✓
注意事项:
1.直流并为-F速度等级目标开关特性只是基于模拟. 规定-F速度等级特点是主题建立FPGA规格后更改.一些限制可能会增加,并会反映在该文档后续版本.该-F速度等 级只在商用温度范围内支持.
* 为-F速度等级目标DC和开关特性只是基于模拟. 规定-F速度等级特点是主题建立FPGA规格后更改.一些限制可能会增加,并会反映在该文档后续版本.该-F速度等 级只在商用温度范围内支持.
v1.0
III
芯片中文手册,看全文,戳
温度等级奉献
包裹
A3P015 A3P030
ARM7设 备
在零件号"G". 6. M1A3P250设备不支持FG256或QN132包.
表 1-1•
ProASIC3 FPGA包装规格尺寸
包裹
QN68
长 ×宽
8×8
(毫米 \毫米)
标称面产品
64
(mm 2)
间距( mm)
0.4
高度( mm)
0.90
QN132 8×8
64
0.5 0.75
VQ100 14 × 14
时钟调理电路( CCC)和 PLL
†
•CCC六块,其中有一个集成PLL
•可配置
相移,
乘法/除法,
Delay
®3
功能和外部反馈
•宽输入频率范围(1.5兆赫至350兆赫)
嵌入式存储器
†
•1千位用户FlashROM非易失性存储器
•静态存储器和FIFO具有可变纵横比4,608位RAM
块(×1,×2,×4,×9,和×18个组织)
A3P600 = 60万系统门 A3P1000 = 1,000,000个系统门
ProASIC3器件与 ARM7