RN2704JE中文资料
HON 270 MK2 气压调节器说明书
2GAS PRESSURE REGULATOR HON 270 MK2Application• D esigned for use on gas pressure reduction services to domestic, business premises and small industrial feeds to burners, heater units, boilers and other items of equipment where an accurate, safe and dependable pressure controlled supply is required.Introduction• T he HON 270 MK2 regulator is a direct acting, single diaphragm, spring loaded open, lever operated regulator for use on gas pressure reduction systems.• C ontrol of varying inlet pressure and capacity applications is ensured by utilising a range of interchangeable orifices of varying size.• U se with confidence on natural and manufactured gases of non-aggressive nature, including Nitrogen, Carbon Dioxide, Propane and Butane.Features• Completely independent operation of regulator and safety cut-off valve.• D iaphragm casing can be rotated through 360º at intervals of 45º to assist servicing and installation in confined spaces.• B oth regulator casing/valve head and safety cut-off valve can be removed from the body as cartridges, ensuring straightforward maintenance without removing the body from the pipeline.• Wide operational pressure range.• Internally or Externally impulsed (ICL/ECL).Size Range1.1/2" and 2" Screwed BS21 Rc & RpDN 50 Flanged to PN16:BS EN 1092-2:1997ASA Class 150InstallationThe regulator may be mounted in any orientation to suit site conditions,moisture or debris must not ingress the vent hole. For optimumperformance the recommended operating position is with diaphragmcasing horizontal and spring housing pointing vertically upwards.It is important when installing equipment that pipeline stresses arekept to a minimum and no undue external forces are placed on theconnections.Options• P - Type : No Internal Relief• R - Type : With Internal Relief• ECL : External Control Line• ICL : Internal Control Line• R egulator can be fitted with theHON 309 Over pressure (OPCO) orcombined Under/Over pressure(UPCO/OPCO) Safety Cut-Off valve.These devices protect the downstreamsystem in the event that a dangerousgas pressure condition develops. Introduction, Application, Features & Technical DataGAS PRESSURE REGULATOR HON 270 MK23Spring Selection, Materials of ConstructionMinimum OPCO & UPCO/OPCO Settings • P - Type: 35 mbar (14" wg) or 10% aboveregulator set point, whichever is the higher • R - Type: 55 mbar (22" wg) when Internal relief fitted• M inimum differential pressure between UPCO and OPCO is 45 mbar (18" wg) and 65 mbar (26" wg) with Internal reliefNote: The HON 309 MP2 Overpressure Cut-Off Valve can be fitted on special request to give a maximum trip pressure of 700mbar (280" wg) - contact Honeywell for details.4GAS PRESSURE REGULATOR HON 270 MK2 PerformanceCapacity PerformanceFor in-control capacities see capacity graphs: Maximum full open capacities can be calculated using the following equations:Sub-Critical Flow(Pe - Pa)≤0.5(Pe + Pb)Q= d(te + 273)6.97Cg(Pe + Pb)sin K1 degExample Calculation: For 2" size with 15mm orifice Conditions : Inlet Pressure (Pe) 1 barg: Outlet Pressure (Pa) 200 mbargMedium : Natural Gas SG= 0.6Test for flow conditions: (1 - 0.2) ≤0.5 (1 + 1.01325)0.8≤1.006*Hence Sub-Critical Flow conditions.Pe + PbPe-PaCritical Flow(Pe - Pa)≤0.5(Pe + Pb)Q= d(te + 273)6.97Cg(Pe + Pb)Full Open Capacity:Q = 0.6(15 + 273) x 294(2.01325)sin 105 deg Q = 287 Sm³/hr6.970.82.1325GAS PRESSURE REGULATOR HON 270 MK25Capacities: DN 50 in sm³/hr for Natural Gas (SG 0.6)I N L E T P R E S S U R E I N L E T P R E S S U R E I N L E T P R E S S U R E Graphs give capacities for internally/externally impulsed and with or without OPCO(refer to correction factors for 40mm (1.1/2") size unit)GAS PRESSURE REGULATOR HON 270 MK26Capacities: DN 50 in sm³/hr for Natural Gas (SG 0.6)Correction Factors40mm (1.1/2") screwedFor calculating the capacity of the 40mm (1.1/2") size unit, obtain the flow capacity from the graphs and multiply by the following correction factors:Orifice Size 0.80.91.032mm 25mm All other sizesCorrection FactorSm³/hr to SCFH: x 35.3Droop: 20%Types of Gases:The capacities shown in the tables are given in terms of natural gas SG 0.6. For allother gases multiply by thefollowing correction factor: 0.6 SG of gas handledN O N -P R I N T A R E Ae B o d i e s2 W a y V e n t V a l v e V e n t C o n n e c t i o n R c 1⁄2L i g h t w e i g h t C a r t r i d g e V a r i a b l e I n t e r n a l R e l i e f V a l v e (O p t i o n a l )B o s s T a p p e d R c ½ f o r EC LI n t e r c h a n g e a b l e S p r i n g sb l e O r i f ic e s8GAS PRESSURE REGULATOR HON 270 MK2Dimensions & WeightsNote: Can berotated in steps of45º at this point+13 when OPCOis not fittedTapped Rc 1⁄8For ECLBoss TappedRc 1⁄2 For ECLOPCO Turned through 180ºwhen internally impulsed.External impulsed OPCO shown113656026170A4827635427H56Service B90Ø350235ServiceGAS PRESSURE REGULATOR HON 270 MK29Internal ReliefTypical InstallationGeneralInlet pressure pointInletblock valve Purge/ventpointFilter(if required)Remote vent lines (if required)OPCOExt. control lineRegulatorPurge/vent point Outlet block valveExternal control lineOutletpressure pointAll contents are subject to copyright, with the possible exception of information that is universal and/or public domain.Honeywell policy is one of continuous improvement and development.The company reserves the right to change, withdraw and introduce improved designs without notice.R.270 2016-03©2016 Honeywell International Inc.For More InformationT o learn more about Honeywell’s Advanced Gas Solutions, visit or contact your Honeywell account manager. Honeywell Process SolutionsHoneywell Bryan Donkin Gas T echnologies Ltd. Enterprise Drive, Holmewood Chesterfield S42 5UZ, England T el: +44 (0)1246 501-501 Fax: +44 (0)1246 501-500 。
PCM2704中文资料
AUDIO DAC WITH USB INTERFACE,ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.PACKAGE ORDERING INFORMATION元器件交易网IMPORTANT NOTICETexas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications,enhancements, improvements, and other changes to its products and services at any time and to discontinueany product or service without notice. Customers should obtain the latest relevant information before placingorders and should verify that such information is current and complete. All products are sold subject to TI’s termsand conditions of sale supplied at the time of order acknowledgment.TI warrants performance of its hardware products to the specifications applicable at the time of sale inaccordance with TI’s standard warranty. T esting and other quality control techniques are used to the extent TIdeems necessary to support this warranty. Except where mandated by government requirements, testing of allparameters of each product is not necessarily performed.TI assumes no liability for applications assistance or customer product design. Customers are responsible fortheir products and applications using TI components. T o minimize the risks associated with customer productsand applications, customers should provide adequate design and operating safeguards.TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right,copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or processin which TI products or services are used. Information published by TI regarding third-party products or servicesdoes not constitute a license from TI to use such products or services or a warranty or endorsement thereof.Use of such information may require a license from a third party under the patents or other intellectual propertyof the third party, or a license from TI under the patents or other intellectual property of TI.Reproduction of information in TI data books or data sheets is permissible only if reproduction is withoutalteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproductionof this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable forsuch altered documentation.Resale of TI products or services with statements different from or beyond the parameters stated by TI for thatproduct or service voids all express and any implied warranties for the associated TI product or service andis an unfair and deceptive business practice. TI is not responsible or liable for any such statements.Following are URLs where you can obtain information on other Texas Instruments products and applicationsolutions:Products ApplicationsAmplifiers Audio /audioData Converters Automotive /automotiveDSP Broadband /broadbandInterface Digital Control /digitalcontrolLogic Military /militaryPower Mgmt Optical Networking /opticalnetworkMicrocontrollers Security /securityTelephony /telephonyVideo & Imaging /videoWireless /wirelessMailing Address:Texas InstrumentsPost Office Box 655303 Dallas, Texas 75265Copyright 2004, Texas Instruments Incorporated。
FD270中文资料
Totalizers electromechanicS u b j e c t t o m o d i fi c a t i o n i n t e c h n i c a n d d e s i g n . E r r o r s a n d o m i s s i o n s e x c e p t e d .008FD270 - Impulse counterFeaturesLarge pulse counter –Adding–Display 5- or 6-digits–Imprint of the measured result on card, paper stripes –or labelsManual imprint, reset and ink ribbon transport by –reset leverTechnical data - electrical ratings Voltage supply115 VAC ±10 % (60 Hz) 230 VAC ±10 % (50 Hz) 24 VDC ±10 %Ripple residue <48 %Nominal frequency 50 / 60 Hz Current consumption ≤600 mA Power consumption 14 W, 20 VA Pulse ratio 1:1ApprovalCE conformFD270Technical data - mechanical design DisplayWhite numbers on black Number of digits 5-digits 6-digitsDigit height7 mm (numeral readout) 3 mm (printed numerals)Count mode1 impulse = 1 count Step-by-step switching Adding in whole steps Measuring range 99 999 and 999 999Reset Manual by reset lever Imprint With lever, without reset By lever upon reset Card thickness ≤0.3 mm Card width 85...0 mmInk ribbon transport Manual by knurled knob Operating temperature 0...+60 °C Storing temperature -20...+70 °CRelative humidity 80 % non-condensing Protection DIN EN 60529IP 41Housing type Housing with ground plate E-connection Cable gland PG 9 MountingSurface mount housing Dimensions W x H x L 237 x 152 x 113.5 mm Weight approx.3500 gMaterialAluminium die cast alloyImpulse counters adding, imprint on card Display 5- or 6-digits, manual reset by leverTotalizers electromechanicS u b j e c t t o m o d i fi c a t i o n i n t e c h n i c a n d d e s i g n . E r r o r s a n d o m i s s i o n s e x c e p t e d .008FD270Part number FD270.DisplayA55-digits 9999.9 A75-digits 99999 C16-digits 999 999B76-digits 99999.5,count mode 0-5-0-5Voltage 124 VDC5115 VAC / 60 Hz 6230 VAC / 50 HzImprint / reset010A Imprint and reset operation parallel020CImprint and reset operation separateImpulse counters adding, imprint on card Display 5- or 6-digits, manual reset by leverConnection diagramDimensionsVoltage 24 VDC ±10 %Power14 W Nominal current 600 mA Resistance 38 ΩVoltage 115 VAC ±10 %Power20 VA Nominal current 180 mA Resistance 50 ΩVoltage 230 VAC +6/-10 %Power20 VA Nominal current 80 mA Resistance290 ΩTrigger level。
AZ2704中文资料
GENERAL DATALife ExpectancyMinimum operations Mechanical 1 x 106Electrical 1 x 105at 30 A 120 VAC Res.Operate Time (max)30 ms at nominal coil voltage Release Time (max)30 ms at nominal coil voltage (with no coil suppression)Dielectric Strength 4000 Vrms coil to contact(at sea level for 1 min.)2000 Vrms between open contacts Insulation 1000 megohms min. at 20°C, 500 VDC,Resistance 50% RHDropoutGreater than 5% of nominal coil voltage (DC)Greater than 15% of nominal coil voltage (AC)Ambient TemperatureAt nominal coil voltageOperating -40°C (-40°F) to 85°C (185°F) - Class B Storage-40°C (-40°F) to 105°C (221°F) - Class F -40°C (-40°F) to 130°C (266°F) - Class B -40°C (-40°F) to 155°C (311°F) - Class F Vibration 0.062" DA at 10–55 HzShockOperating 10 g, 11 ms, 1/2sine (no false operation)Non-Operating 100 g, 11 ms, 1/2sine (no damage)EnclosureP.B.T. polyesterTerminalsTinned copper alloy, PC mountMax. Solder Temp.270°C (518°F)Max. Solder Time 5 seconds Weight120 grams30 AMP POWER RELAYFEATURES •Low cost•30 Amp switching•Class B insulation system standard, Class F available •PC mount •4 kV dielectric•Standard (2.4 mm) and wide contact gap (3.0 mm) available •UL, CUR file E44211•TÜV R50031999NOTES1.All values at 20°C (68°F).2.Relay may pull in with less than “Must Operate” value.3.Specifications subject to change without notice.COILPowerAt Pickup Voltage 1.08 W (DC)(typical)1.2 VA (AC)Max. Continuous 3.8 W at 20°C (68°F) ambient Dissipation Temperature Rise 50°C (90°F) at nominal coil voltage TemperatureMax. 130°C (266°F) - Class B Max. 155°C (311°F) - Class FCONTACTSArrangement SPST (1 Form X)DPST (2 Form X)RatingsResistive load:Max. switched power: 840 W or 8310 VA Max. switched current: 30 AMax. switched voltage: 150* VDC or 400 VAC*Note: If switching voltage is greater than 30VDC, special precautions must be taken. Please contact the factory.Rated Load 30 A at 277 VAC res. 30k cycles [1]UL, CUR1.5 HP at 120 VAC [1]3 HP at 240 VAC [1]TV-10 at 120 VAC [1]30 A at 277 VAC res. 70k cycles [2]3 HP at 240 VAC 100k cycles [2]10 A at 120 VAC tungsten load, 10k cycles [2]TÜV27 A at 240 VAC, cos phi = .8, 100k cycles [1][1] silver cadmium oxide,[2] silver tin oxide (1 Form X only)Material Silver cadmium oxide, silver tin oxide Resistance< 100 milliohms initially(24 V, 1 A voltage drop method)COIL SPECIFICATIONS – AC COILORDER NUMBER*Nominal Coil Must Operate Max. Continuous Coil Current1 Form X2 Form XVAC VAC VAC mA ± 10%6 4.80 6.6319AZ2704–1A–6A AZ2704–2A–6A 129.6013.2160AZ2704–1A–12A AZ2704–2A–12A 2419.226.480AZ2704–1A–24A AZ2704–2A–24A 4838.452.840AZ2704–1A–48A AZ2704–2A–48A 12096.0132.023AZ2704–1A–120A AZ2704–2A–120A 220176.0242.010AZ2704–1A–220A AZ2704–2A–220A 240192.0264.09.2AZ2704–1A–240A AZ2704–2A–240A*For silver tin oxide add suffix “T” (UL approved for 1 Form X version only). For wide contact gap add “W”. For Class F add suffix “F”.MECHANICAL DATARELAY ORDERING DATACOIL SPECIFICATIONS – DC COILORDER NUMBER*Nominal CoilMust OperateMax. ContinuousCoil Resistance1 Form X2 Form X VDC VDC VDC ± 10%3 2.25 4.2 4.7AZ2704–1A–3D AZ2704–2A–3D 6 4.508.418.8AZ2704–1A–6D AZ2704–2A–6D 129.0016.875AZ2704–1A–12D AZ2704–2A–12D 2418.0033.7300AZ2704–1A–24D AZ2704–2A–24D 4836.067.51200AZ2704–1A–48D AZ2704–2A–48D 10075.0140.55200AZ2704–1A–100D AZ2704–2A–100D 11082.5154.76300AZ2704–1A–110D AZ2704–2A–110D 200150.0282.421000AZ2704–1A–200DAZ2704–2A–200D。
吉佛兰电子设备产品介绍说明书
AUTOMATIONPOWER CONTROLSOLID STATE RELAYS, AND POWER CONTROLLERSENG C O D . 81141D - 03/20152Thanks to forty years of experience, Gefran is the world leader in the design and production of solutions for measuring, controlling, and driving industrial production processes .We have 14 branches in 12 countries and a network of over 80 worldwide distributors.For 40 years, Gefran has been designing and producing technologically advanced actuators and solid state relays to control resistive/inductive loads and infrared lamps used in modern temperature control systems.Our knowledge of the market transforms your needs into practical, high-quality answers.QUALITY AND TECHNOLOGYGefran components are a concentrate of technology , the result of constant research and of cooperation with major research centres .Thanks to its complete line of controllers and actuators , Gefran can be your sole provider of solutions for electrical heating control .Gefran’s know-how and experience guarantee continuous and practical solutions.SERVICESA team of Gefran experts works with the customer to select the ideal product for its application and to help install andconfiguredevices(***********************).Gefran offers a wide range of courses at different levels for the technical-commercial study of the Gefran product range as well as specific courses on demandIn addition to foreseeing the market’s application needs, Gefran forms partnerships with its customers to find the best way to optimise and boost the performance of various applications .Gefran products communicate with one another to provide integrated solutions, and can dialogue with devices by other companies thanks to compatibility with numerous fieldbuses.APPLICATIONSPLASTICS HEAT TREATMENTGLASSENERGYPAPERFOODSOFTWAREGF_eXpressConfiguration kit for Gefran instruments by means of PC (Windows environment).- A single software for all models- Easy configuration- Copy/paste, save recipe, trendfunctions- Rapid configuration of instruments- Saving and management of parameterrecipes- On-line trend and saving of historicaldata- Recovery of factory settings- Custom linearization- On-line user manual- Easy programming with custom messages- Easy graphics programming with setpointprogrammersIR SOLUTIONPRINTINGTEXTILEPLASTICS – BLOWINGWOODWORKING MACHINESPHOTOVOLTAICSAUTOMOTIVE Halogen - 2500°CShort Wave - 2200°C4SOLID STATE RELAYS, AND POWER CONTROLLERSGTF - GFWGTF and GTF-XTRAGTF is the new line of GEFRAN power controllers, designedto control all types of industrial electric heaters.Versatility, plus easy and guided configuration with GEFRAN(25,40A)(400, 600A)(400, 600A)GS (15... 120A)GD (40A)SOLID STATE RELAYS, AND POWER CONTROLLERSFIELDBUS*(25...60A)GTF(25...250A)GFWFIELDBUS*GFX4-IRFIELDBUS* (25... 120A)GT(25... 120A)(*) European Patent N° 2660843 8SOLID STATE RELAYS, AND POWER CONTROLLERS(*) European Patent N° 2660843 10SOLID STATE RELAYS, AND POWER CONTROLLERSnot availablex = (1pcs)SOLID STATE RELAYS, AND POWER CONTROLLERS(**) Valid formulas for Vline=Vload(***) For these applications it is recommanded to contact the Gefran specialistsnon disponibilex = (1pz)SOLID STATE RELAYS, AND POWER CONTROLLERS(**) Valid formulas for Vline=Vload(***) For these applications it is recommanded to contact the Gefran specialistsSPAINMEXICO TAIWAN INDIARUSSIABELGIUM UK TURKEYSINGAPOREGERMANYCHINA SWITZERLAND FRANCE USA BRAZILSOUTH AFRICAITALYDrive & Motion Control Unit Via Carducci, 2421040 GERENZANO (VA) ITALY Ph. +39 02967601Fax +39 029682653**********************Technical Assistance:*********************Customer Service*************************Ph. +39 02 96760500 Fax +39 02 96760278GEFRAN HEADQUARTER Via Sebina, 7425050 PROVAGLIO D’ISEO (BS) ITALY Ph. +39 03098881Fax +39 0309839063GEFRAN DEUTSCHLAND GmbH Philipp-Reis-Straße 9a D-63500 Seligenstadt Ph. +49 (0) 61828090Fax +49 (0) 6182809222******************SIEI AREG - GERMANY Gottlieb-Daimler Strasse 17/3D-74385 - Pleidelsheim Ph. +49 (0) 7144 897360Fax +49 (0) 7144 8973697****************SENSORMATE AGSteigweg 8,CH-8355 Aadorf, Switzerland Ph. +41(0)52-2421818 Fax +41(0)52-3661884http://www.sensormate.ch GEFRAN FRANCE SA4, rue Jean Desparmet - BP 823769355 LYON Cedex 08Ph. +33 (0) 478770300Fax +33 (0) 478770320********************GEFRAN BENELUX NV ENA 23 Zone 3, nr . 3910 Lammerdries-Zuid 14A B-2250 OLENPh. +32 (0) 14248181Fax +32 (0) 14248180**************GEFRAN UK Ltd Unit 7Brook Business Centre 54a Cowley Mill Road Uxbridge UB8 2FXPh. +44 (0) 8452 604555Fax +44 (0) 8452 604556 ***************.ukGEFRAN ESPAÑACalle Vic, números 109-11108160 - MONTMELÓ(BARCELONA)Ph. +34 934982643Fax +34 935721571**************************GEFRAN MIDDLE EAST ELEKTRIK VE ELEKTRONIK San. ve Tic. Ltd. Sti Yesilkoy Mah. AtaturkCad. No: 12/1 B1 Blok K:12 D: 389 Bakirkoy /Istanbul TURKIYEPh. +90212 465 91 21Fax +90212 465 91 22GEFRAN RUSSIA4 Lesnoy pereulok, 4B usiness center “White Stone” 125047, Moscow, Russia Tell: +7 (495) 225-86-20 Fax: +7 (495) 225-85-00GEFRAN SOUTH AFRICA Pty Ltd.Unit 10 North Precinet, West Bu-ildingTopaz Boulevard Montague Park, 7411, Cape Town Ph. +27 21 5525985 Fax +27 21 5525912GEFRAN SIEIDrives Technology Co., Ltd No. 1285, Beihe Road, Jiading District, Shanghai, China 201807Ph. +86 21 69169898Fax +86 21 69169333***************.cnGEFRAN INDIASurvey No: 182/1 KH, Bhukum, Paud road, Taluka – Mulshi,Pune - 411 042. MH, INDIA Phone No.:+91-20-39394400Fax No.: +91-20-39394401**********************GEFRAN TAIWANNo.141, Wenzhi Rd., Zhongli City, Taoyuan County 32054, Taiwan (R.O.C.)Ph. +886-3-4273697*********************.sg GEFRAN Inc.8 Lowell AvenueWINCHESTER - MA 01890Toll Free 1-888-888-4474Fax +1 (781) 7291468******************GEFRAN BRASILELETROELETRÔNICA Avenida Dr . Altino Arantes,377 Vila Clementino04042-032 SÂO PAULO - SP Ph. +55 (0) 1155851133Fax +55 (0) 1132974012********************.br。
台湾明纬开关电源型号(澜孚)LanFu、(明纬)MW、( 衡孚)HF
台湾明纬开关电源单组输出功率:从15W-2KW,型号齐全;低价,高可靠;效率高,工作温度低;尺寸小,重量轻;内置滤波器,低纹波;内附突入电流抑制电路;一年保修;满载烧机测试;库存现货齐全,交货期短..台湾明纬开关电源2组输出功率:从30W-155W,型号齐全;低价,高可靠;效率高,工作温度低;尺寸小,重量轻;内置滤波器,低纹波;内附突入电流抑制电路;一年保修;满载烧机测试;库存现货齐全,交货期短;…台湾明纬开关电源三组输出功率:从30W-155W,型号齐全;低价,高可靠;效率高,工作温度低;尺寸小,重量轻;内置滤波器,低纹波;一年保修;满载烧机测试;库存现货齐全,交货期短;…台湾明纬开关电源四组输出功率:60W、120W、180W;低价,高可靠;效率高,工作温度低;尺寸小,重量轻;内置滤波器,低纹波;内附突入电流抑制电路;满载烧机测试;内置外壳式开关稳压电源高性能G3系列明纬开关电源河南总经销!广州明纬电源深圳明纬电源明纬电源北京代理深圳明纬电源明纬电源网站台湾明纬电源官网 24v明纬电源型号如下:内置外壳型交换式电源供应器-高性能G3系列RS-25 RS-35 RS-50 RS-75 RS-100 RS-150 RD-35 RD-50 RD-65 RD-85 RD-125 RID-50 RID-65 RID-85 RID-125 RT-50 RT-65 RT-85 RT-125 RQ-50 RQ-65 RQ-85 RQ-125内置外壳型交换式电源供应器-泛用型G2系列S-25 S-40 S-60 S-100F S-150 S-240 S-250 S-320 T-40 T-60 T-120 T-115 D -60 D-120 ID-60 Q-60 Q-120 Q-250 IQ-60 IT-60 SE-600内置外壳型交换式电源供应器-经济型G1系列S-15 S-35 S-50 S-100 S-145 S-201 S-350 D-30 D-50 ID-30 ID-50 T-30 T-5 0内置外壳型交换式电源供应器-PFC系列SP-75 SP-100 SP-150 SP-200 SP-300 SP-320 SP-480 SP-500 SP-750 TP-75 TP-100 TP-150 QP-100 QP-150 QP-200 QP-375 USP-225内置外壳型交换式电源供应器-附带UPS功能型AD系列ADS-55 AD-55 ADD-55 ADS-155 AD-155 ADD-155内置外壳型交换式电源供应器-模组化系列MP-450 MP-650 MP-1000 MS-75 MS-150 MS-300 MD-100广州明纬电源深圳明纬电源明纬电源北京代理深圳明纬电源明纬电源网站台湾明纬电源官网 24v明纬电源内置外壳型交换式电源供应器-轨道型系列DR-45 DR-75 DR-120 DRP-240 DRP-480 DRP-480S DRT-240 DRT-480 DRT-960内置外壳型交换式电源供应器-并联系列PSP-300 PSP-500 PSP-600 PSP-1000 PSP-1500 RSP-1500 SCN-600 SCN-800 SCN-1K2 SCN-1K5 SCN-2K0 SCP-600 SCP-800 SCP-1K2 SCP-2K4内置PCB型交换式电源供应器-板上型OFM-5000 OFM-0100 OFM-1500 OFM-0200内置PCB型交换式电源供应器-泛用型PS-25 PS-45 PD-65 PD-45 PD-25 PD-110 PT-45 PT-65 PT-4503 PT-6503 PS-65 PTsb-50 PTsb-75 PQ-100 PPQ-100 PPS-125 PPT-125 LPS-50 LPS-75 LP S-100 LPP-100 LPP-150内置PCB型交换式电源供应器-医疗类MPS-30 MPS-45 MPS-65 MPS-120 MPD-45 MPD-65 MPD-120 MPT-45 MPT-65 MPT-120 MPQ-120外置型交换式电源供应器-充电型PA-120 PB-120 PS-120 ESC-120 ESP-120 ESP-240外置型交换式电源供应器-桌上型GI-12 ES18A ES18B ES18C ES25A ES25B ES25C P25A P25B P30A P30B P40A P4 0B P50A P66A U65S外置型交换式电源供应器-医疗用桌上型MES-30A MES-30B MES-30C外置型交换式电源供应器-插墙型NP-12 ES18U ES18E ES25U ES25EDC/AC直流/交流转换器-修正正弦波150W 300W 600W 1000W 1500W 2500WDC/AC直流/交流转换器-纯正弦波150W 300W 600W 1500W广州明纬电源深圳明纬电源明纬电源北京代理深圳明纬电源明纬电源网站台湾明纬电源官网 24v明纬电源。
TP270设备手册
缩写
本手册中使用的这些缩写词具有下列含义
AG (PLC)
可编程逻辑控制器
ANSI
美国国家标准协会
AS 511
PU 接口到 SIMATIC S5 的协议
当地时间 17:30 电话
传真
星期一至星期五 8:30 到
+65 740-7000 +65 740-7001
电子信箱 authorization@ nbgm.siemens.de
电子信箱 simatic.hotline@
电子信箱 simatic.hotline@ .sg
附录
• 技术数据 • 接口分配 • HMI 系统消息 • ESD 指南
约定
以下约定适用于本手册
电机关
操作单元显示中的文本用这种打印字体显示
变量
画面上代表变量值的符号名以这种斜体打印字体显示
画面
可供选择的功能以这种斜体字体表示
ESC 键
键和按钮的名称用不同的字体来显示
i
前言
历史 其它支持
本手册的不同版本对应于以下 ProTool CS 组态软件的不同版本
前言 目录
引言
1
功能
2
调试
3
操作
4
操作画面和画面对象
5
配方
6
归档
7
系统设置
8
安装
9
尺寸
10
选项
11
维护/保养
12
操作系统更新
制导雷达 SITRANS LG270 四线制 Modbus 转换器版本 操作说明书
制导雷达SITRANS LG270四线制 Modbus转换器版本,带两个腔室,同轴测量探头 -196 … +280 ℃; -196 … +450 ℃操作说明书 • 04/20162PBD-51041273SITRANS LG270 - 操作说明书44296-ZH-1605273PBD-51041273SITRANS LG270 - 操作说明书44296-Z H -160527目录1关于本文献资料1.1 功能 .............................................................................................................................................................................51.2 对象 .............................................................................................................................................................................51.3 使用的标记.. (52)为了您的安全2.1 获得授权的人员.........................................................................................................................................................62.2 合规使用 .....................................................................................................................................................................62.3 谨防错误使用.............................................................................................................................................................62.4 一般安全提示.............................................................................................................................................................62.5 CE 认证 .......................................................................................................................................................................62.6 NAMUR 推荐 (63)产品说明3.1 结构 .............................................................................................................................................................................73.2 作业方式 .....................................................................................................................................................................83.3 包装、运输和仓储 ....................................................................................................................................................93.4 附件与备件 (104)安装4.1 一般提示 ...................................................................................................................................................................114.2安装提示 (11)5与供电电源和总线系统相连接5.1 准备接线 ...................................................................................................................................................................165.2 连接 ...........................................................................................................................................................................165.3 接线图 .......................................................................................................................................................................185.4 带 DISADAPT 的双腔式壳体................................................................................................................................195.5 附加电子部件...........................................................................................................................................................205.6 启动阶段 . (206)对带有显示和调整模块的传感器进行调试6.1 操作范围 ...................................................................................................................................................................216.2 使用显示和调整模块 ..............................................................................................................................................216.3 操作系统 ...................................................................................................................................................................226.4 参数化 - 快速调试 ..................................................................................................................................................236.5 参数化 - 扩展了的操作功能..................................................................................................................................236.6 对设置的参数数据的存储 .. (387)将传感器和 Modbus 接口连同 PACTware 一起投入使用7.1 连接计算机...............................................................................................................................................................397.2 通过 PACTware 设置参数.....................................................................................................................................407.3 设置仪表地址...........................................................................................................................................................417.4 通过快速调试来投入使用 ......................................................................................................................................427.5 对设置的参数数据的存储 .. (438)诊断与服务8.1 维护 ...........................................................................................................................................................................448.2 诊断储存器...............................................................................................................................................................448.3 状态报告 ...................................................................................................................................................................448.4 排除故障 ...................................................................................................................................................................488.5 更换电子插件...........................................................................................................................................................508.6 软件升级 ...................................................................................................................................................................508.7 需要维修时的步骤 .. (519)拆卸9.1 拆卸步骤 ...................................................................................................................................................................529.2废物清除 (52)4PBD-51041273SITRANS LG270 - 操作说明书44296-ZH-16052710 附件10.1 技术数据 ...................................................................................................................................................................5310.2 Modbus 的依据......................................................................................................................................................6110.3 Modbus 寄存器......................................................................................................................................................6310.4 Modbus RTU 指令 ................................................................................................................................................6510.5 Levelmaster 指令 ..................................................................................................................................................6810.6 典型的 Modbus 主机的配置................................................................................................................................7210.7 尺寸 ...........................................................................................................................................................................7710.8商标 (79)用于防爆区域的安全提示请在将仪表用于防爆应用领域时遵守专门针对防爆的安全说明。
RN1421中文资料
· The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any intellectual property or other rights of TOSHIBA CORPORATION or others.
RN1421~1427
Input voltage (ON)
Input voltage (OFF) Transition frequency Collector Output capacitance Input resistor
Resistor ratio
RN1421 RN1422 RN1423 RN1424 RN1425 RN1426 RN1427 RN1421~1424 RN1425, 1426 RN1427 RN1421~1427
Weight: 0.012 g (typ.)
Unit V V
V
mA mW °C °C
1
2002-02-08
元器件交易网
Electrical Characteristics (Ta = 25°C)
Characteristic
RMG_270 详解
2GAS PRESSURE REGULATOR SERiES 270 MK2Application• D esigned for use on gas pressure reduction services to domestic, business premises and small industrial feeds to burners, heater units, boilers and other items of equipment where an accurate, safe and dependable pressure controlled supply is required.introduction• T he Series 270 MK2 regulator is a direct acting, single diaphragm, spring loaded open, lever operated regulator for use on gas pressure reduction systems.• C ontrol of varying inlet pressure and capacity applications is ensured by utilising a range of interchangeable orifices of varying size.• U se with confidence on natural and manufactured gases of non-aggressive nature, including Nitrogen, Carbon Dioxide, Propane and Butane.Features• Completely independent operation of regulator and safety cut-off valve.• D iaphragm casing can be rotated through 360º at intervals of 45º to assist servicing and installation in confined spaces.• B oth regulator casing/valve head and safety cut-off valve can be removed from the body as cartridges, ensuring straightforward maintenance without removing the body from the pipeline.• Wide operational pressure range.• Internally or Externally impulsed (ICL/ECL).Size Range1.1/2” and 2” Screwed BS21 Rc & RpDN 50 Flanged to PN16 :BS EN 1092-2:1997ASA Class 150installationThe regulator may be mounted in any orientation to suit siteconditions, moisture or debris must not ingress the vent hole. Foroptimum performance the recommended operating position is withdiaphragm casing horizontal and spring housing pointing verticallyupwards.It is important when installing equipment that pipeline stresses arekept to a minimum and no undue external forces are placed on theconnections.Options• P - Type : No Internal Relief• R - Type : With Internal Relief• ECL : External Control Line• ICL : Internal Control Line• R egulator can be fitted with theSeries 309 Over pressure (OPCO) orcombined Under/Over pressure(UPCO/OPCO) Safety Cut-Off valve.These devices protect the downstreamsystem in the event that a dangerousgas pressure condition develops. Introduction, Application, Features & Technical DataGAS PRESSURE REGULATOR SERiES 270 MK23Spring Selection, Materials of ConstructionMinimum OPCO & UPCO/OPCO Settings • P - Type: 35 mbar (14” wg) or 10% aboveregulator set point, whichever is the higher • R - Type: 55 mbar (22” wg) when Internal relief fitted• M inimum differential pressure between UPCO and OPCO is 45 mbar (18” wg) and 65 mbar (26” wg) with Internal reliefNote: The Series 309 MP2 Overpressure Cut-Off Valve can be fitted on special request to give a maximum trip pressure of 700mbar (280” wg) - contact BD-RMG for details.4GAS PRESSURE REGULATOR SERiES 270 MK2 PerformanceCapacity PerformanceFor in-control capacities see capacity graphs: Maximum full open capacities can be calculated using the following equations:Sub-Critical Flow(Pe - Pa)≤0.5(Pe + Pb)Q= d(te + 273)6.97Cg(Pe + Pb)sin K1 degExample Calculation: For 2” size with 15mm orifice Conditions : Inlet Pressure (Pe) 1 barg: Outlet Pressure (Pa) 200 mbargMedium : Natural Gas SG= 0.6Test for flow conditions: (1 - 0.2) ≤0.5 (1 + 1.01325)0.8≤1.006*Hence Sub-Critical Flow conditions.Pe + PbPe-PaCritical Flow(Pe - Pa)≤0.5(Pe + Pb)Q= d(te + 273)6.97Cg(Pe + Pb)Full Open Capacity:Q = 0.6(15 + 273) x 294(2.01325)sin 105 deg Q = 287 Sm³/hr6.970.82.1325GAS PRESSURE REGULATOR SERiES 270 MK25Capacities: DN 50 in sm ³/hr for Natural Gas (SG 0.6)i N L E T P R E S S U R E i N L E T P R E S S U R E i N L E T P R E S S U R E Graphs give capacities for internally/externally impulsed and with or withut OPCO(refer to correction factors for 40mm (11/2”) size unit)W a y V e n t V a l v e n t C o n n e c t i o n R c 1⁄2L i g h t w e i g h t C a r t r i d g e V a r i a b l e I n t e r n a l R e l i e f V a l v e (O p t i o n a l )B o s s T a p p e d R c ½ f o r EC LI n t e r c h a n g e a b l e S p r i n g s8GAS PRESSURE REGULATOR SERiES 270 MK2Dimensions & WeightsNote: Can berotated in steps of45º at this point+13 when OPCOis not fittedTapped Rc 1⁄8For ECLBoss TappedRc 1⁄2 For ECLOPCO Turned through 180ºwhen internally impulsed.External impulsed OPCO shown113656026170A4827635427H56Service B90Ø350235ServiceGAS PRESSURE REGULATOR SERiES 270 MK29internal ReliefTypical installationGeneralInlet pressure pointInletblock valve Purge/ventpointFilter(if required)Remote vent lines (if required)OPCOExt. control lineRegulatorPurge/vent point Outlet block valveExternal control lineOutletpressure pointAll contents are subject to copyright, with the possible exception of information that is universal and/or public domain.Bryan Donkin RMG Gas Controls Limited policy is one of continuous improvement and development.The company reserves the right to change, withdraw and introduce improved designs without notice.ENGLANDHoneywell Process Solutions Bryan Donkin RMG Gas Controls Ltd. Enterprise Drive, Holmewood Chesterfield S42 5UZ, England Tel: +44 (0)1246 501-501 Fax: +44 (0)1246 501-500CANADAHoneywell Process Solutions Bryan Donkin RMG Canada Ltd. 50 Clarke Street South, Woodstock Ontario N4S 0A8, Canada Tel: +1 (0)519 5398531 Fax: +1 (0)519 5373339USAHoneywell Process Solutions Mercury Instruments LLC 3940 Virginia Avenue Cincinnati, Ohio 45227, USA Tel: +1 (0)513 272-1111 Fax: +1 (0)513 272-0211TURKEYHoneywell Process SolutionsRMG GAZ KONT. SIS. ITH. IHR. LTD. STI. Birlik Sanayi Sitesi, 6. Cd. 62. Sokak No: 7-8-9-10 TR - Sasmaz / Ankara, Turkey Tel: +90 (0)312 27810-80 Fax: +90 (0)312 27828-23GERMANYHoneywell Process Solutions RMG Regel + Messtechnik GmbH Osterholzstrasse 45 34123 Kassel, Germany Tel: +49 (0)561 5007-0 Fax: +49 (0)561 5007-107Honeywell Process Solutions RMG Messtechnik GmbH Otto-Hahn-Strasse 5 35510 Butzbach, Germany Tel: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130Honeywell Process SolutionsRMG Gaselan Regel + Messtechnik GmbH Julius-Pintsch-Ring 315517 Fürstenwalde, Germany Tel: +49 (0)3361 356-60 Fax: +49 (0)3361 356-836Honeywell Process Solutions WÄGA Wärme-Gastechnik GmbH Osterholzstrasse 45 34123 Kassel, Germany Tel: +49 (0)561 5007-0 Fax: +49 (0)561 5007-207POLANDHoneywell Process Solutions Gazomet Sp. z o.o. ul. Sarnowska 2 63-900 Rawicz, Poland Tel: +48 (0)65 5462401 Fax: +48 (0)65 5462408For More informationTo learn more about RMG's advanced gas solutions, contact your RMG account manager or visit R.2702010-10© 2010 Honeywell International Inc.。
LG 遥控器指南说明书
3. While recording, you can enjoy Blu-ray4. Use w/s/a/d to select a recording title.5. Press z (PLAY) or ENTER (b) to play therecording title.,Notey X mark is displayed in recording now. Ifyou want to play the title in recording, pressz (PLAY) or ENTER (b), but you mayhave some restriction to operate trick playfeatures.y N mark is displayed in recorded files thatnever once played since it was recorded.Recording from Program Guide menuYou can also set the timer based on the information provided by the Program guide menu.1.While watching TV, press GUIDE.e a/d to select date field, and select thedate of recording schedule using w/s.e a/d to select programme field, and setthe programme using w/s.e a/d to select the programme list, andselect a programme you want to record using w/s.5. Press the red coloured (R) button.For the successfully scheduled programme, a red bullet mark appears.A red bullet mark may not appear forinavailable programme to record.6.Press BACK (1) to return to the TV viewing.7.Press TIMER REC, and check whether theschedule is registered properly or not.Tip for Using Program Guide menu1. You can use PR (-/+) to change page onProgram guide menu.2. You can change date by using green coloured(G) button on Program guide menu.3. Series recording cannot be used when theBroadcaster do not include series informationwith the program data.4. To see Timer Recording list, press BACK (1)to return to the TV viewing and then, pressTIMER REC to check whether the schedule isregistered properly or not.You can play from selected time1. Press INFO/MENU(m) during playback. Thetime search box shows the elapsed playingtime.2. Select the [Time] option and then input therequired start time in hours, minutes, andseconds from left to right.For example, to find a scene at 2 hours, 10minutes, and 20 seconds, enter “21020”.Press a/d to skip the playback forward orbackward for 60 seconds.3. Press ENTER (b) to start playback from selectedtime.。
RN2402中文资料
Characteristic
Collector-base voltage Collector-emitter voltage
Emitter-base voltage
Collector current Collector power dissipation Junction temperature Storage temperature range
元器件交易网
RN2401,RN2402,RN2403,RN2404,RN2405,RN2406
3
2001-06-07
元器件交易网
RN2401,RN2402,RN2403,RN2404,RN2405,RN2406
4
2001-06-07
元器件交易网
−1.52
−0.38
―
−0.71
−0.17
―
−0.082 ―
−0.33 mA
−0.15
−0.078 ― −0.145
−0.074 ― −0.138
30
―
―
50
―
―
70
―
―80
―
―
80
―
―
―
−0.1 −0.3
V
−1.1
―
−2.0
−1.2
―
−2.4
−1.3
―
−3.0
V
−1.5
―
−5.0
−0.6
―
―
― VCE = −0.2V ― IC = −5mA
―
―
― VCE = −5V, ― IC = −0.1mA
―
VCE = −10V, IC = −5mA
―
VCB = −10V, IE = 0 f = 1MHz
LM2704MF-ADJ资料
LM2704Micropower Step-up DC/DC Converter with 550mA Peak Current LimitGeneral DescriptionThe LM2704is a micropower step-up DC/DC in a small 5-lead SOT-23package.A current limited,fixed off-time control scheme conserves operating current resulting in high efficiency over a wide range of load conditions.The 21V switch allows for output voltages as high as 20V.The low 400ns off-time permits the use of tiny,low profile inductors and capacitors to minimize footprint and cost in space-conscious portable applications.The LM2704is ideal for LCD panels requiring low current and high efficiency as well as white LED applications for cellular phone back-lighting.The LM2704can drive up to 8white LEDs from a single Li-Ion battery.Featuresn 550mA,0.7Ω,internal switchn Uses small surface mount components n Adjustable output voltage up to 20V n 2.2V to 7V input range n Input undervoltage lockout n 0.01µA shutdown currentnSmall 5-Lead SOT-23packageApplicationsn LCD Bias Suppliesn White LED Back-Lighting n Handheld Devices n Digital CamerasnPortable ApplicationsTypical Application Circuit20031501FIGURE 1.Typical 20V ApplicationApril 2003LM2704Micropower Step-up DC/DC Converter with 550mA Peak Current Limit©2003National Semiconductor Corporation Connection DiagramTop View20031502SOT23-5T Jmax=125˚C,θJA =220˚C/W (Note 2)Ordering InformationOrder Number Package Type NSC Package DrawingTop Mark Supplied AsLM2704MF-ADJ SOT23-5MA05B S28B 1000Units,Tape and Reel LM2704MFX-ADJSOT23-5MA05BS28B3000Units,Tape and ReelPin Description/FunctionsPin Name Function1SW Power Switch input.2GND Ground.3FB Output voltage feedback input.4SHDN Shutdown control input,active low.5V INAnalog and Power input.SW(Pin 1):Switch Pin.This is the drain of the internal NMOS power switch.Minimize the metal trace area con-nected to this pin to minimize EMI.GND(Pin 2):Ground Pin.Tie directly to ground plane.FB(Pin 3):Feedback Pin.Set the output voltage by selecting values for R1and R2using:Connect the ground of the feedback network to an AGND plane which should be tied directly to the GND pin.SHDN(Pin 4):Shutdown Pin.The shutdown pin is an active low control.Tie this pin above 1.1V to enable the device.Tie this pin below 0.3V to turn off the device.V IN (Pin 5):Input Supply Pin.Bypass this pin with a capacitor as close to the device as possible.L M 2704 2Absolute Maximum Ratings(Note1) If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/ Distributors for availability and specifications.V IN7.5V SW Voltage21V FB Voltage2V SHDN Voltage7.5V Maximum Junction Temp.T J(Note2)150˚CLead Temperature(Soldering10sec.)300˚C Vapor Phase(60sec.)215˚CInfrared(15sec.)220˚C ESD Ratings(Note3)Human Body ModelMachine Model(Note4)2kV200V Operating ConditionsJunction Temperature(Note5)−40˚C to+125˚C Supply Voltage 2.2V to7V SW Voltage Max.20.5VElectrical Characteristics(Note5)Specifications in standard type face are for T J=25˚C and those in boldface type apply over the full Operating Temperature Range(T J=−40˚C to+125˚C).Unless otherwise specified.V IN=2.2V.Symbol Parameter ConditionsMin(Note5)Typ(Note6)Max(Note5)UnitsI Q Device Disabled FB=1.3V4070µA Device Enabled FB=1.2V235300Shutdown SHDN=0V0.01 2.5V FB Feedback Trip Point 1.189 1.237 1.269VI CL Switch Current Limit490420550610620mAI B FB Pin Bias Current FB=1.23V(Note7)30120nA V IN Input Voltage Range 2.27.0V R DSON Switch R DSON0.7 1.6ΩT OFF Switch Off Time400ns I SD SHDN Pin Current SHDN=V IN,T J=25˚C080nASHDN=V IN,T J=125˚C15SHDN=GND0I L Switch Leakage Current V SW=20V0.055µA UVP Input Undervoltage Lockout ON/OFF Threshold 1.8VV FB Hysteresis Feedback Hysteresis8mVSHDN Threshold SHDN low0.70.3V SHDN High 1.10.7θJA Thermal Resistance220˚C/W Note1:Absolute maximum ratings are limits beyond which damage to the device may occur.Operating Ratings are conditions for which the device is intended to be functional,but device parameter specifications may not be guaranteed.For guaranteed specifications and test conditions,see the Electrical Characteristics.Note2:The maximum allowable power dissipation is a function of the maximum junction temperature,T J(MAX),the junction-to-ambient thermal resistance,θJA, and the ambient temperature,T A.See the Electrical Characteristics table for the thermal resistance.The maximum allowable power dissipation at any ambient temperature is calculated using:P D(MAX)=(T J(MAX)−T A)/θJA.Exceeding the maximum allowable power dissipation will cause excessive die temperature.Note3:The human body model is a100pF capacitor discharged through a1.5kΩresistor into each pin.The machine model is a200pF capacitor discharged directly into each pin.Note4:ESD susceptibility using the machine model is150V for SW pin.Note5:All limits guaranteed at room temperature(standard typeface)and at temperature extremes(bold typeface).All room temperature limits are100% production tested or guaranteed through statistical analysis.All limits at temperature extremes are guaranteed via correlation using standard Statistical Quality Control(SQC)methods.All limits are used to calculate Average Outgoing Quality Level(AOQL).Note6:Typical numbers are at25˚C and represent the most likely norm.Note7:Feedback current flows into the pin.LM27043Typical Performance CharacteristicsEnable Current vs V IN(Part Switching)Disable Current vs V IN (Part Not Switching)2003150520031506Efficiency vs Load Current Efficiency vs Load Current2003151020031511L M 2704 4Typical Performance Characteristics(Continued)Efficiency vs Load CurrentSHDN Threshold vs V IN2003151220031513Switch Current Limit vs V IN Switch R DSON vs V IN2003151420031515LM27045Typical Performance Characteristics(Continued)FB Trip Point and FB Pin Current vs TemperatureOutput Voltage vs Load Current2003153820031537Step Response Start-Up/Shutdown20031516V OUT =20V,V IN =3.0V1)Load,1mA to 17mA to 1mA,DC 2)V OUT ,200mV/div,AC 3)I L ,500mA/div,DC T =40µs/div20031517V OUT =20V,V IN =2.5V 1)SHDN,1V/div,DC 2)I L ,250mA/div,DC 3)V OUT ,20V/div,DC T =400µs/div R L =1.3k ΩL M 2704 6Operation20031504FIGURE 2.LM2704Block Diagram20031518V OUT =20V,V IN =2.5V 1)V SW ,20V/div,DC2)Inductor Current,500mA/div,DC 3)V OUT ,100mV/div,AC T =10µs/divFIGURE 3.Typical Switching WaveformLM27047Operation(Continued)The LM2704features a constant off-time control scheme.Operation can be best understood by referring to Figure 2and Figure 3.Transistors Q1and Q2and resistors R3and R4of Figure 2form a bandgap reference used to control the output voltage.When the voltage at the FB pin is less than 1.237V,the Enable Comp in Figure 2enables the device and the NMOS switch is turned on pulling the SW pin to ground.When the NMOS switch is on,current begins to flow through inductor L while the load current is supplied by the output capacitor C OUT .Once the current in the inductor reaches the peak current limit,the CL Comp trips and the 400ns One Shot turns off the NMOS switch.The SW voltage will then rise to the output voltage plus a diode drop and the inductor current will begin to decrease as shown in Figure 3.During this time the energy stored in the inductor is transferred to C OUT and the load.After the 400ns off-time the NMOS switch is turned on and energy is stored in the inductor again.This energy transfer from the inductor to the output causes a stepping effect in the output ripple as shown in Figure 3.This cycle is continued until the voltage at FB reaches 1.237V.When FB reaches this voltage,the enable compara-tor then disables the device turning off the NMOS switch and reducing the Iq of the device to 40uA.The load current is then supplied solely by C OUT indicated by the gradually decreasing slope at the output as shown in Figure 3.When the FB pin drops slightly below 1.237V,the enable compara-tor enables the device and begins the cycle described pre-viously.The SHDN pin can be used to turn off the LM2704and reduce the I q to 0.01µA.In shutdown mode the output voltage will be a diode drop lower than the input voltage.Application InformationINDUCTOR SELECTIONThe appropriate inductor for a given application is calculated using the following equation:where V D is the schottky diode voltage,I CL is the switch current limit found in the Typical Performance Characteris-tics section,and T OFF is the switch off time.When using this equation be sure to use the minimum input voltage for the application,such as for battery powered applications.For the LM2704constant-off time control scheme,the NMOS power switch is turned off when the current limit is reached.There is approximately a 200ns delay from the time the current limit is reached in the NMOS power switch and when the internal logic actually turns off the switch.During this 200ns delay,the peak inductor current will increase.This increase in inductor current demands a larger saturation current rating for the inductor.This saturation current can be approximated by the following equation:Choosing inductors with low ESR decrease power losses and increase efficiency.Care should be taken when choosing an inductor.For appli-cations that require an input voltage that approaches the output voltage,such as when converting a Li-Ion battery voltage to 5V,the 400ns off time may not be enough time to discharge the energy in the inductor and transfer the energy to the output capacitor and load.This can cause a ramping effect in the inductor current waveform and an increased ripple on the output ing a smaller inductor will cause the I PK to increase and will increase the output voltage ripple further.This can be solved by adding a 4.7pF capaci-tor across the R F1feedback resistor (Figure 2)and slightly increasing the output capacitor.A smaller inductor can then be used to ensure proper discharge in the 400ns off time.DIODE SELECTIONTo maintain high efficiency,the average current rating of the schottky diode should be larger than the peak inductor cur-rent,I PK .Schottky diodes with a low forward drop and fast switching speeds are ideal for increasing efficiency in por-table applications.Choose a reverse breakdown of the schottky diode larger than the output voltage.CAPACITOR SELECTIONChoose low ESR capacitors for the output to minimize output voltage ripple.Multilayer ceramic capacitors are the best choice.For most applications,a 1µF ceramic capacitor is sufficient.For some applications a reduction in output volt-age ripple can be achieved by increasing the output capaci-tor.Local bypassing for the input is needed on the LM2704.Multilayer ceramic capacitors are a good choice for this as well.A 4.7µF capacitor is sufficient for most applications.For additional bypassing,a 100nF ceramic capacitor can be used to shunt high frequency ripple on the input.LAYOUT CONSIDERATIONSThe input bypass capacitor C IN ,as shown in Figure 1,must be placed close to the IC.This will reduce copper trace resistance which effects input voltage ripple of the IC.For additional input voltage filtering,a 100nF bypass capacitor can be placed in parallel with C IN to shunt any high fre-quency noise to ground.The output capacitor,C OUT ,should also be placed close to the IC.Any copper trace connections for the Cout capacitor can increase the series resistance,which directly effects output voltage ripple.The feedback network,resistors R1and R2,should be kept close to the FB pin to minimize copper trace connections that can inject noise into the system.The ground connection for the feed-back resistor network should connect directly to an analog ground plane.The analog ground plane should tie directly to the GND pin.If no analog ground plane is available,the ground connection for the feedback network should tie di-rectly to the GND pin.Trace connections made to the induc-tor and schottky diode should be minimized to reduce power dissipation and increase overall efficiency.L M 2704 8Application Information(Continued)20031509FIGURE 4.White LED Application20031534FIGURE 5.Li-Ion 5V Application20031535FIGURE 6.Li-Ion 12V ApplicationLM27049Application Information(Continued)20031536FIGURE 7.5V to 12V ApplicationL M 2704 10Physical Dimensionsinches (millimeters)unless otherwise noted5-Lead Small Outline Package (M5)For Ordering,Refer to Ordering Information TableNS Package Number MA05BLIFE SUPPORT POLICYNATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION.As used herein:1.Life support devices or systems are devices or systems which,(a)are intended for surgical implant into the body,or (b)support or sustain life,and whose failure to perform when properly used in accordance with instructions for use provided in the labeling,can be reasonably expected to result in a significant injury to the user.2.A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system,or to affect its safety or effectiveness.National Semiconductor Americas Customer Support CenterEmail:new.feedback@ Tel:1-800-272-9959National SemiconductorEurope Customer Support CenterFax:+49(0)180-5308586Email:europe.support@Deutsch Tel:+49(0)6995086208English Tel:+44(0)8702402171Français Tel:+33(0)141918790National Semiconductor Asia Pacific Customer Support Center Fax:+65-62504466Email:ap.support@ Tel:+65-62544466National SemiconductorJapan Customer Support Center Fax:81-3-5639-7507Email:jpn.feedback@ Tel:81-3-5639-7560LM2704Micropower Step-up DC/DC Converter with 550mA Peak Current LimitNational does not assume any responsibility for use of any circuitry described,no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications.元器件交易网。
R404A R507 12V DC直流压缩器
June 2013 DES.D.100.K4.02 1/2BD220CLDirect Current Compressor R404A/R50712V DC- with 101N08xx Series ControllersGeneralCode number (without electronic units)102Z3020Compressor module 101N0800, 30 pcs: 101N0801Application module101N0820, 24 pcs: 101N0821Alternative (one interface only):Electronic Unit (no fan connection/no twin option)101N0830, 30 pcs: 101N0831Approvals–Compressors on pallet 125Application ApplicationLBPEvaporating temperature °C -45 to -5Voltage rangeVDC 9.6 - 17Max. condensing temperature continuous (short)°C 50 (60)Max. winding temperature continuous (short)°C125 (135)Cooling requirements Application LBP MBP HBP 32°C F 1––38°C F 1––43°CF 1––Remarks on application: - evaporator fan max. 200W - condenser fan max. 100W Motor Motor typevariable speedResistance, all 3 windings (25°C)Ω0.1Design Displacement cm 3 3.86Oil quantity (type)cm3280 (polyolester)Maximum refrigerant charge g 400Free gas volume in compressor cm 31690Weight - Compressor/Electronic unit kg7.9 / 0.33 / 0.28 (101N820)Battery protection settings Voltage Min. valueDefault Max. valueCut out (0.1 steps)VDC 9.610.417Cut in diff.(0.1 steps)VDC0.51.310Dimensions Heightmm A173B 169B1–B2–Suction connector location/I.D. mm | angle C6.2 | 90°material | comment Cu-plated steel | Al capProcess connector location/I.D. mm | angle D6.2 | 31.5°material | comment Cu-plated steel | Al capDischarge connector location/I.D. mm | angle E5.0 | 28°material | commentCu-plated steel | Al cap Connector toleranceI.D. mm±0.09, on 5.0 +0.12/+0.20S = Static cooling normally sufficient O = Oil coolingF 1 = Fan cooling 1.5 m/s(compressor compartment temperature equal to ambient temperature)F 2 = Fan cooling 3.0 m/s necessarySG = Suction gas cooling normally sufficent –= not applicable in this area2/2 DES.D.100.K4.02 June 2013Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary to specifications already agreed. All trademarks in this material are the property of the respective companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved.Test conditionsEN 12900/CECOMAF ASHRAE LBPCondensing temperature 45°C 45°CAmbient temperature 32°C 32°CSuction gas temperature 32°C 32°CLiquid temperatureno subcooling 32°CAccessories for BD220CLMountingCode number Bolt joint for one compressor Ø: 16 mm 118-1917Bolt joint in quantities Ø: 16 mm 118-1918Snap-on in quantities Ø: 16 mm118-1919Electrical (cables, sensors, etc.)Code numberSingle pack I - PackOne Wire/LIN gateway 105N9501–communication cable 105N9524–Bluetooth® gateway 105N9502–communication cable 105N9525–Temperature sensor 470 mm 105N9612105N9613, 200 pcs.Temperature sensor 1000 mm 105N9614105N9615, 100 pcs.Temperature sensor 1500 mm 105N9616105N9617, 100 m. cable, 1500 mm –105N9553, 80 m. cable, 3000 mm –105N9554, 45 pcs.Display cable, 1500 mm –105N9557, 65 pcs.Display cable, 3000 mm –105N9558, 35 pcs.Not deliverable from Secop Slow-blow fuse compressor module 60A Slow-blow fuse application module 30A Main switch rated to min. 100A Operational errors Errorcode Error typeCan be read out in the software TOOL4COOL®6Thermostat failure(If the NTC thermistor is short-circuit or has no connection,the electronic unit will enter manual mode).5Thermal cut-out of electronic unit(If the refrigeration system has been too hea v i l y loaded, or if the ambient tem p e r a t ure is high, the electronic unit will run too hot).4Minimum motor speed error(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately 1,850 rpm).3Motor start error(The rotor is blocked or the differential pressure in the refrigeration system is too high).2Fan over-current cut-out(The fan loads the electronic unit with too high current).1Battery protection cut-out(The voltage is outside the cut-out setting).。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
TOSHIBA Transistor Silicon PNP Epitaxial Type (PCT process) (Bias Resistor built-in Transistor)RN2701JE,RN2702JE,RN2703JE RN2704JE,RN2705JE,RN2706JESwitching, Inverter Circuit, Interface Circuit and Driver Circuit Applications.· Two devices are incorporated into an Extreme-Super-Mini (5 pin)package. · Incorporating a bias resistor into a transistor reduces parts count.Reducing the parts count enable the manufacture of ever more compact equipment and save assembly cost. · Complementary to RN1701JE~RN1706JEEquivalent Circuit and Bias Resistor ValuesMaximum Ratings (Ta = 25°C) (Q1, Q2 common)Characteristics SymbolRatingUnitCollector-base voltage V CBO -50 V Collector-emitter voltage RN2701JE~RN2706JE V CEO -50 V RN2701JE~RN2704JE -10 Emitter-base voltage RN2705JE, RN2706JEV EBO -5VCollector currentI C -100 mA Collector power dissipation P C (Note)100 mWJunction temperature T j 150 °CStorage temperature rangeRN2701JE~RN2706JE T stg-55~150°CNote: Total ratingUnit: mmJEDEC― JEITA ― TOSHIBA―Weight: g (typ.)Equivalent Circuit (top view)Type No.R1 (k W ) R2 (k W )RN2701JE 4.7 4.7 RN2702JE 10 10 RN2703JE 22 22 RN2704JE 4747 RN2705JE 2.2 47 RN2706JE 4.747BElectrical Characteristics (Ta = 25°C) (Q1, Q2 common)Characteristics Symbol Test Condition Min Typ. Max UnitI CBO V CB = -50 V, I E = 0 ¾ ¾ -100Collector cut-off currentRN2701JE~2706JEI CEOV CE = -50 V, I B = 0¾ ¾ -500nARN2701JE -0.82 ¾ -1.52RN2702JE-0.38 ¾ -0.71RN2703JE -0.17 ¾ -0.33RN2704JE V EB = -10 V, I C = 0-0.082¾ -0.15RN2705JE -0.078 ¾ -0.145Emitter cut-off currentRN2706JEI EBOV EB = -5 V, I C = 0-0.074¾-0.138mA RN2701JE 30 ¾ ¾RN2702JE 50 ¾ ¾RN2703JE 70 ¾ ¾ RN2704JE 80 ¾ ¾RN2705JE 80 ¾ ¾ DC current gainRN2706JEh FE V CE = -5 V,I C = -10 mA 80 ¾ ¾Collector-emittersaturation voltageRN2701JE~2706JE V CE (sat)I C = -5 mA, I B = -0.25 mA¾ -0.1 -0.3VRN2701JE -1.1 ¾ -2.0 RN2702JE-1.2 ¾ -2.4 RN2703JE -1.3 ¾ -3.0 RN2704JE -1.5 ¾ -5.0 RN2705JE -0.6 ¾ -1.1 Input voltage (ON)RN2706JEV I (ON)V CE = -0.2 V, I C = -5 mA -0.7 ¾ -1.3 V RN2701JE~2704JE -1.0 ¾ -1.5Input voltage (OFF) RN2705JE, 2706JE V I (OFF) V CE = -5 V, I C = -0.1 mA -0.5¾-0.8V Transition frequency RN2701JE~2706JEf TV CE = -10 V, I C = -5 mA¾ 200 ¾ MHz Collector output capacitanceRN2701JE~2706JE C obV CB = -10 V, I E = 0, f = 1 MHz¾ 3 6 pFRN2701JE 3.29 4.7 6.11RN2702JE 7 10 13RN2703JE 15.4 22 28.6RN2704JE32.9 47 61.1RN2705JE 1.54 2.2 2.86Input resistorRN2706JER1¾3.294.7 6.11k WRN2701JE~2704JE0.9 1.0 1.1 RN2705JE 0.0421 0.0468 0.0515Resistor ratioRN2706JER1/R2¾0.09 0.1 0.11Type NameMarking· TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property.In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc.. · The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer’s own risk. · The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any intellectual property or other rights of TOSHIBA CORPORATION or others. · The information contained herein is subject to change without notice.000707EAARESTRICTIONS ON PRODUCT USE。