18650锂电池组技术规格书
朔明商标 ICR18650 锂二极电池规格表说明书
Library Sort Product Specifications VER IILibrary Name Cylindrical Li‐ion Rechargeable Battery Date 2004/4/30Cylindrical Li-ion batterySpecificationType: ICR18650Prepared/Date Auditing/Date Approved/Date Genxiao Li Peng kun Gao Dragon LvLibrary Sort Product Specifications VER II Library Name Cylindrical Li‐ion Rechargeable Battery Date 2004/4/301.PerformanceTest item Test conditions Requirements(1)Outside Appearance Visual check No abnormal stain,Deformation nor damage(2) Standard test conditions Measurements are carried out at 20±5℃and relative humidity of 65±20% without other specified condition.Accuracy of voltmeters and ammeters used in test is equal to or better than the grade 0.5.(3) Standard charge Battery is charged continuously at the constant current of 0.5 I t end at voltage of 4.2V, then charge at the constant voltage of 4.2V until the end current of 20mA after Pre-discharge at the constant current of 0.2 I t until the end voltage of 2.75V/cell(4) Fast charge Charge shall be conducted continuously at theconstant current of 1500mA until the end voltage of4.2V, then charge at the constant voltage of 4.2Vuntil the end current of 20mA after Pre-dischargementioned in Item (2).(5)Open-circuitvoltage (OCV)≥3.75V(6)Rated Capacity Discharge duration of the charged battery specifiedin Item (3) shall be measured at 0.2 I t mA until theend voltage of 2.75V/cell, after rest for 0.25 hour.If the discharge duration does not reach thespecified value, the test may be repeated up to threetimes in total.Rated capacity:≥100%C5mAh(7)Capacity high-rate discharge Discharge duration of the charged battery specifiedin Item (3) shall be measured at 1500mA until the endvoltage of 2.75V/cell, after rest for 0.25 hour. Ifthe discharge duration does not reach the specifiedvalue, the test may be repeated up to three times intotal.Discharge capacity:≥90%C5mAh(8) Cycle Life (20℃) Carry out cycles (1500mA CC/CV(4.2V), discharge atthe constant current of 1500mA after rest for 0.25hour) at20± 2℃. The test end until the dischargecapacity <60%C5mAh≥300 cyclesLibrary Sort Product Specifications VER II Library Name Cylindrical Li‐ion Rechargeable Battery Date 2004/4/30(9)Low temperature discharge 1)charge shall be conducted at Item (3);2)Thebattery shall be stored under -20℃±2℃ for 16h~24h;3)Discharge shall be conducted at the constantcurrent of 0.2I t mA until the end voltage of2.75V/cell;Discharge capacity:≥60%C5mAh2 Mechanical testTest Item Test Conditions Requirements(1)Vibration Test Vibrate test sample for 90minutes each at roomtemperature after rated charge.Amplitude: 0.38mm(10-30Hz);0.19mm(30-55Hz)Frequency: 10-55Hz(1oct/min)Direction: X, YThen measure resistance, voltage of battery andcheck outside appearance.No rupture, fire, smoke,Nor critical damage≧90% C5mAh(2) Drop Test Drop 100% charged test sample from 1m above ontoconcrete board with more than 5cm thickness two timeseach for every direction at room temperature.Then measure rated capacity and checks outsideappearance. No rupture, fire, smoke, Nor critical damage≧90% C5mAh3 Safety evaluationTest Item Test Conditions Requirements(1) Hot Oven Test The charged battery is to be heated in a gravityconvection or circulating air oven. The temperatureof the oven is to be raised at a rate of 5±2℃ perminute. The oven is to remain for 30 minutes at 150±2℃ before the test is discontinued.No fire, Nor explosion(2)Short Circuit Test After fast charge at 20±2℃, Connect batteryterminals with electric wire ( electric resistance:50mΩor less ). And stop the test when thetemperature of battery is 10℃lower than peaktemperature.No fire, Nor explosion(3) Overcharge Test After discharged at 1 I t mA and end at 2.75V, thebattery shall be charged at 3 I t mA current with avoltage limit of 4.6V.No fire, Nor explosion(4)Dip test The charged battery shall be dipped in water for 24hin an ambient temperature of 20℃±5℃.No fire, Nor explosionLibrary Sort Product Specifications VER IILibrary Name Cylindrical Li‐ion Rechargeable Battery Date 2004/4/304 Charge State of Battery before shipmentTo be determined.(Recommendation Approx. 3.75 – 3.85V 30% charge)5 Duration of guarantee the productWe can keep on the quality in six month.6 Handling precautions on Lithium Ion Rechargeable BatteryTo assure product safety, describe the following precautions in the instruction manual of the equipment.! Danger-When charging the battery, use dedicated chargers and follow the specified conditions.-Use the battery only in the specified equipment.-Do not connect battery directly to an electric outlet or cigarette lighter charger.-Do not heat or throw battery into a fire.-Do not use, leave battery close to fire or inside of a car where temperature may be above 60℃. Also do not charge / discharge in such conditions.-Do not immerse, throw, and wet battery in water/ seawater.-Do not put batteries in your pockets or a bag together with metal objects such as necklaces.Hairpins, coins, or screws. Do not store batteries with such objects.-Do not short circuit the (+) and (-) terminals with other metals.-Do not place battery in a device with the (+) and (-) in the wrong way around.-Do not pierce battery with a sharp object such as a needle.-Do not hit with a hammer, step on or throw or drop to cause strong shock.-Do not disassemble or modify the battery.-Do not solder a battery directly.-Do not use a battery with serious scar or deformation.! Warning-Do not put battery into a microware oven, dryer, or high-pressure container.-Do not use battery with dry cells and other primary batteries, or batteries of a different package, type, or brand.-Stop charging the battery if charging is not completed within the specified time.-Stop using the battery if abnormal heat, odor, discoloration, deformation or abnormal condition is detectedDuring use, charge, or storage.-Keep away from fire immediately when leakage or foul odor is detected.-If liquid leaks onto your skin or clothes, wash well with fresh water immediately.If liquid leaking from the battery gets into your eyes, do not rub your eyes. Wash them well with clean water and go to see a doctor immediately.! Caution-Store batteries out of reach of children so that they are not accidentally swallowed.Library Sort Product Specifications VER IILibrary Name Cylindrical Li‐ion Rechargeable Battery Date 2004/4/30-If younger children use the battery, their guardians should explain the proper handling. -Before using the battery, be sure to read the user’s manual and cautions on handling thoroughly.-Thoroughly read the user’s manual for the charger before charging the battery.-For information on installing and removing from equipment, thoroughly read the user’s manual for the specific equipment.-Batteries have life cycles. If the time that the battery powers equipment becomes much shorter than usual, the battery life is at an end. Replace the battery with a new same one.-Remove a battery whose life cycle has expired from equipment immediately.-When the battery is thrown away, be sure it is non-conducting by applying vinyl tape to the (+) and (-) terminals.-When not using battery for an extended period, remove it from the equipment and store ina place with low humidity and low temperature.-While the battery pack is charged, used and stored, keep it away from objects or materials with static electric charges.-If the terminals of the battery become dirty, wipe with a dry clothe before using the battery. -The battery can be used within the following temperature ranges. Do not exceed these ranges.Charge temperature range : 0℃ to 45℃Discharge temperature range : -20℃ to 60℃(When using equipment)。
18650电池规格书
LGCRP/BTC Ryu, Duk HyunLRB-PS-CY2402003-07-16 0ApprovedDescriptionLGCRP/BTC Kim, Soo Ryoung Lithium Ion ICR18650 A3P R O D U C T S P E C I F I C A T I O NRechargeable Lithium Ion Battery Model : ICR18650 A3 2400mAhREVISIONDATE ORIGINATOR REASON FOR CHANGE 0 2004-07-16Ryu, Duk HyunOriginal ReleasePrepared Reviewed Approved Ryu, Duk HyunJung, Jae HanKim, Soo RyoungDate :’04. 07. 16. Date : ’03. 07. 16.Date : ’04. 07. 16.20 YOIDO-DONG YOUNGDUNGPO-GU,SEOUL 150-721, KOREATEL : (82) 2-3773-3599, 3659 FAX : (82) 2-3773-7005LGCRP/BTC Ryu, Duk Hyun LRB-PS-CY240 2003-07-16 0Approved DescriptionLGCRP/BTC Kim, Soo Ryoung Lithium Ion ICR18650 A31. ScopeThis product specification defines the requirements of the rechargeable lithium ion battery to be supplied to the customer by LG Chem, Ltd. Should there be any additional information required by the customer, customers are advised to contact LG Chem, Ltd. before selecting a solution.2. Description and Model2.1 Description : Rechargeable Lithium Ion Battery2.2 Model : ICR18650 A33. Technical Information3.1 Capacity Nominal : 2430 mAh (by standard charge and discharge)Minimum : 2380 mAh3.2 Nominal V oltage : Average 3.7 V3.3 Standard Charge : Constant Current and Constant V oltage (CC/CV)mACurrent =1200V oltage = 4.2 VEnd Current = 50 mA3.4 Max. Charge Current : 2400 mA3.5 Standard Discharge : Constant Current (CC)Current = 480 mAEnd V oltage = 3.0 V3.6 Max. Discharge Current : 4800 mA (for continuous discharge)3.7 Weight : Approx. 46.1 g3.8 Operating Temperature Charge :0 to 45 o CDischarge : -20 to 60 o C3.9 Storage Temperature 1 month : -20 to 60 o C3 months : -20 to 45 o C1 year : -20 to 20 o CLGCRP/BTC Ryu, Duk Hyun LRB-PS-CY240 2003-07-16 0Approved DescriptionLGCRP/BTC Kim, Soo Ryoung Lithium Ion ICR18650 A34. Cell DimensionsDiameter : 18.3 ± 0.1 mm ( Max. 18.4 mm )Height : 64.9 ± 0.2 mm ( Max. 65.1 mm )5. AppearancesThere shall be no such defects as deep scratch, crack, rust, discoloration or leakage, which may adversely affect the commercial value of the cell.6. Characteristics6.1 Standard ChargeUnless otherwise specified, “Standard Charge” shall consist of charging at constant current of 1200mA. The cell shall then be charged at constant voltage of 4.2V while tapering the charge current. Charging shall be terminated when the charging current has tapered to 50mA. For test purposes, charging shall be performed at 23ºC ± 2ºC.6.2 Standard Discharge“Standard Discharge” shall consist of discharging at a constant current of 480mA to 3.0V.Discharging is to be performed at 23 ºC ± 2 ºC unless otherwise noted (such as capacity versus temperature).6.3 Initial CapacityCells shall be charged per 6.1 and discharged per 6.2 within 1 hour after full charge. Initial capacity shall meet the following requirement.Initial Capacity ≥ 2380 mAh6.4 Cycle LifeCells shall be charged at constant current of 1200mA to 4.2V with end current of 50mA. Cells shall be discharged at constant current of 1200mA to 3.0V. Cells are to rest 10 minutes after charge and20 minutes after discharge. A cycle is defined as one charge and one discharge. Discharge capacityshall be measured per 6.1 and 6.2 after 300 cycles.Discharge capacity (301th Cycle) ≥80 % (of minimum capacity in 3.1)6.5 Initial AC ImpedanceLGCRP/BTC Ryu, Duk Hyun LRB-PS-CY240 2003-07-16 0Approved DescriptionLGCRP/BTC Kim, Soo Ryoung Lithium Ion ICR18650 A3Initial AC impedance is measured at 1kHz after standard charge.Initial AC Impedance ≤ 90 mΩ (with PTC)6.6 Temperature Dependency of CapacityCells shall be charged per 6.1 at 23ºC ± 2ºC and discharged per 6.2 at the following temperatures.Relative capacity at each temperature shall meet the following.Charge Temp. Discharge Temperature-10ºC0ºC 23ºC 60ºC23ºC70 % 90 % 100 % 95 %6.7 Storage CharacteristicsCells shall be charged per 6.1 and stored in a temperature-controlled environment at 23ºC ± 2ºC for30 days. After storage, cells shall be discharged per 6.2 to obtain the remaining capacity.Remaining capacity ≥90 % (of minimum capacity in 3.1)6.8 Cell V oltage (as of shipment)V oltage range : 3.7 ~ 3.9 V7. Mechanical Characteristics7.1 Drop TestTest method : Cells charged per 6.1 are dropped onto an wooden floor from 4 feet height for 3 cycles, where each cycle consists of 3 drops, 2 drops from each cell terminal and1drop from the side of cell can (Total number of drops = 9). After test, cells aredischarged per 6.2 and cycled per 6.1 and 6.2 for 3 cycles to obtain recoveredcapacity.Criteria : No leakage, Capacity recovery rate ≥ 80 %7.2 Vibration TestTest method : Cells charged per 6.1 are vibrated for 90 minutes per each of the three mutually perpendicular axis (x, y, z) with an amplitude of 0.8mm, frequency of 10Hz to55Hz and sweep of 1Hz change per minute. After test, cells are discharged per6.2 and cycled per 6.1 and 6.2 for 3 cycles to obtain recovered capacity.Criteria : No leakage, Capacity recovery rate ≥ 80 %LGCRP/BTC Ryu, Duk Hyun LRB-PS-CY240 2003-07-16 0Approved DescriptionLGCRP/BTC Kim, Soo Ryoung Lithium Ion ICR18650 A38. Environmental Test8.1 High Temperature Storage TestTest method : Cells are charged per 6.1 and stored in a temperature-controlled environment at 60ºC for 1 week. After test, cells are discharged per 6.2 and cycled per 6.4 for 3cycles to obtain recovered capacity.Criteria : No leakage, Capacity recovery rate ≥ 80 %8.2 High Temperature and High Humidity TestTest method : Cells are charged per 6.1 and stored at 60ºC (95% RH) for 168 hours. After test, cells are discharged per 6.2 and cycled per 6.4 for 3 cycles to obtain recoveredcapacity.Criteria : No leakage, No rust, Capacity recovery rate ≥ 80 %8.3 Thermal Shock TestTest method : 65ºC (8Hrs) ← 3hrs →-20ºC (8Hrs) for 8 cycles with cells charged per 6.1.After test, cells are discharged per 6.2 and cycled per 6.4 for 3 cycles to obtainrecovered capacity.Criteria : No leakage, Capacity recovery rate ≥ 80 %9. Safety Test9.1 Abnormal Charge TestTest method : Cells are discharged per 6.2, then charged at constant current of 7200mA and constant voltage of 4.2V while tapering the charge current. Charging is continuedfor 48 hours (Per UL1642).Criteria : No rupture, No fire9.2 External Short-circuiting TestTest method : Cells are charged per 6.1, and the positive and negative terminal is connected bya 100mΩ-wire for 1 hour (Per UL1642).Criteria : No rupture, No fire9.3 Overdischarge TestTest method : Cells are discharged at constant current of 480mA to 250% of the minimum capacity (Per UL1642).Criteria : No rupture, No fireLGCRP/BTC Ryu, Duk Hyun LRB-PS-CY240 2003-07-16 0Approved DescriptionLGCRP/BTC Kim, Soo Ryoung Lithium Ion ICR18650 A39.4 Nail TestTest method : A nail (diameter : 2.5~5mm) is penetrated vertically through the center of cells charged per 6.1 and left for 6 hours.Criteria : No rupture, No fire9.5 Heating TestTest method : Cells are charged per 6.1 and heated in a circulating air oven at a rate of 5ºC per minute to 150ºC. At 150ºC, oven is to remain for 10 minutes before test isdiscontinued (Per UL1642).Criteria : No rupture, No fire9.6 Impact TestTest method : Cells charged per 6.1 are impacted with their longitudinal axis parallel to the flat surface and perpendicular to the longitudinal axis of the 15.8mm diameter bar(Per UL1642).Criteria : No rupture, No fire9.7 Crush TestTest method : Cells charged per 6.1 are crushed with their longitudinal axis parallel to the flat surface of the crushing apparatus (Per UL1642).Criteria : No rupture, No fire10. Standard Test ConditionsUnless otherwise specified, all tests stated in this Product Specification are conducted at temperature 23±2ºC and humidity 65 ± 20 %RH.11. Product LiabilityThe coverage of LG Chem, Ltd. is for the cell itself, while the customer assumes the liability of the product including the cell and its protection circuit.12. WarrantyAs long as the cell is treated in accordance with this Product Specification and/or Proper Use and Handling, LG Chem, Ltd. warrants that the cell should be free from any defect for a period of 1 year from date of manufacturing.LGCRP/BTC Ryu, Duk Hyun LRB-PS-CY240 2003-07-16 0 Approved DescriptionLGCRP/BTC Kim, Soo Ryoung Lithium Ion ICR18650 A3The warranty set forth above or described in Proper Use and Handling excludes a defect which is not related to manufacturing on the cell.13. OthersAny matter not included in this specification shall be conferred between the both parties.This document shall replace the document bearing a former revision index, and customers are kindly requested to destroy the former document in possession.LGCRP/BTC Ryu, Duk Hyun LRB-PS-CY240 2003-07-16 0 Approved DescriptionLGCRP/BTC Kim, Soo Ryoung Lithium Ion ICR18650 A3Fig 1. Dimensional Drawing of ICR18650 A3。
18650单电芯规格书
18650单电芯规格书BATTERY CO., LTD. DOC NO.: QR-WI-733-003-002/A REV. : APAGE: 1 of 8Specification Approval Sheet (cylinder Cell) 产品规格确认书(圆柱电池)Model/型号:ZZ18650Capacity/容量:1500mAhVoltage/电压:3.7V制定(Prepared By)审核(CheckedBy)批准(ApprovedBy)DOC NO.: QR-WI-733-003-002/A REV. : APAGE: 2 of 81.0基本特性Basic performance型号Model BJ18650P 外壳材质Can Material 镀镍钢Nickel-plated 标称容量NominalCapacity,(0.2C5A)1300mAh额定电压Nominal 3.70V 充电截止电压Max 4.20 V 放电终止电压 2.80V 最大充电电流Max.Charge Current1C5A标准持续放电流10C5A最大瞬间放电电流Max. Discharge Curent20 C5A电池最大直径(光壳)18.5电池最大高度(光壳)66mm 电池重量(Approx.) 约36g 内阻(Max, at 1000Hz.)≤16mΩ充电方法Charge 标准0.2C5A×快速 1 C5A×操作温度Operating Temperature 充电Charge0℃~45℃放电Discharge-20℃~60℃贮存Storage-10℃~45℃2.0 外形图figure2.1结构图Structure3.0 主要放电曲线Mainly capability graphBJ18650P-1300mAh 15C Discharge Cruve BJ18650P-1300mAh 1C Charge CruveBJ18650P-1300mAh 13C Cycle Life BJ18650P-1300mAh -20℃Discharge CruveDOC NO.: QR-WI-733-003-002/A REV. : APAGE: 3 of 84.0 电池性能Characteristic若没有特别说明,电池在做各项试验前,均需在86KPa~106 KPa大气压,环境温度20℃±5℃,相对湿度为45%~75%的条件下,以0.2C5A恒流放电至终止电压2.8V,并在收到产品两周内进行以下试验。
18650锂电池组技术规格书
YAGEO
6
R9,R10
Resistor
SMD 5.1KΩ±5%
0603
2
YAGEO
7
R7
合金电阻
P=1W
SMD 10mΩ±5%
2512
1
YAGEO
8
R6
Resistor
SMD 51Ω±5%
0603
1
YAGEO
9
C1,C2,C3
Capacitor
SMD 0.22μF
0603
3
YAGEO
10
C5,C6
断开短路电路
内阻
RSS
主回路通态电阻
RSS≤65mΩ
消耗电流
IDD
工作时电路内部消耗
30.0μA Max
零 V 充电
OV
向0 V电池充电(电芯电压最小1.7V)
允许
4 Parts list主要元件清单
NO.
元件编号
元件名称
元件规格
封装式
数量
厂商/备注
1
U1
Batteryprotection IC
S8254AANFT-TB-G
TSSOP-16
1
SEIKO
2
Q3,Q4
Silicon MOSFET
AO4407
SO-8
2
AOS
3
R1,R2,R3
Resistor
SMD 510Ω±5%
0603
3
YAGEO
4
R4,R5,R11
Resistor
SMD 10KΩ±5%
0603
3
YAGEO
5
R8
Resistor
友创伟业 YCY Li-ion 18650 3.7V 2200mAh电池说明书
SpecificationSeries系列:圆柱锂离子电池Pack Type组合类型:电芯+保护板+引线Model No.型号:YCY Li-ion186503.7V2200mAhCapacity容量:2200mAhVersion版本:01Customer Approve客户确认Company Name客户名称Dept.部门Signature签名Date日期QA Dept品质R&D Dept研发Approved批准1.SCOPE使用范围This specification is applied to the reference battery in this specification and manufactured by Shenzhen YCY Technology Co.,Ltd本说明书适用于本书中所提及的深圳市友创伟业科技有限公司生产的锂电池。
12Max.Continuous Discharge Current最大连续放电电流 1.5CmA 13Operation Temperature Range操作温度Charge 充电:0~45℃60±25%R.H.Discharge 放电:-20~60℃14Storable Temperature Range储存温度1year 一年-20~25℃60±25%R.H.3months 三个月-20~40℃1week 一周-20~60℃15Weight 重量Approx 约:48.0gBattery pack 电池包16Dimension尺寸Height :64.9±0.2mm (Max.50.1mm )Battery CELL电芯Diameter :18.3±0.1mm (Max.18.4mm )3.Performance And Test Conditions3.1Standard Test Conditions 标准测试条件Test should be conducted with new batteries within one week after shipment from our factory and the batterys shall not be cycled more than five times before the test.Unless otherwise defined,test and measurement shall be done under temperature of 20±5℃and relative humidity of 45~85%.If it is judged that the test results are not affected by such conditions,the tests may be conducted at temperature 15~30℃and humidity 25~85%RH.测试必须使用出厂时间不超过一个星期的新电池,且未进行过五次以上的充放电循环。
量能科技圆柱18650锂电池-2200mAh产品规格书
Specification for Li-ion Rechargeable cylindrical battery圆柱锂离子电池规格书MODEL/型号: 18650-2200mAh1.0 SPECIFICATIONS基本特性2.0 CONFIGURATION外形图DiameterHeight3.0 The definitions of some nomenclatures of this specification标准中的一些术语的定义:(1)Standard Charge: Charge with current 0.5C5A to limit charge voltage 4.2V under the condition of 25℃±5℃surrounding temperature, then change to charge with constant voltage till the current less than or equal to 0.01 C5A.标准充电:在环境温度20℃±5℃的条件下,以0.5C5A充电,当电池端电压达到充电限制电压4.2V时,改为恒压充电,直到充电电流小于或等于0.01C5A后停止充电(2)Initial State: The initial appearance, open-circuit voltage and internal resistance of battery.初始状态:电池的初始外观、开路电压、交流内阻。
(3)Final State: The final appearance, open-circuit voltage and internal resistance of battery.最终状态:电池的最终外观、开路电压、交流内阻。
(4)Residual Capacity: After a specific testing program, the first discharge capacity of battery.剩余容量:电池经过特定的检测程序后的首次放电容量。
18650(3600mah)规格书(标准书)
18650(3600mah)规格书(标准书)文件名称产品型号修改记录产品型号目录1 适用范围 (4)2 引用标准 (4)3 定义........................................ .. (4)3.1 手机用电池battery for cellular phone ..... . (4) 3.2 充电限制电压 limited charge voltage ............... .. (4)3.3 额定容量 rated capacity ........................... .. (4)3.4 标称电压 nominal voltage (4)3.5 终止电压 cut-off voltage (4)4 技术参数 (4)4.1 电芯参数表 (4)4.2 主要参数表 (5)4.3 保护板参数表 (5)5 要求 (5)5.1 测试条件 (5)5.2 测量仪表与设备要求 (6)5.3 外观 (6)5.4 充电制式 (6)5.5 20℃放电性能 (6)5.6 高温性能 (6)5.7 低温性能 (6)5.8 荷电保持能力 (6)5.9 循环寿命 (7)5.10 环境适应性 (7)5.11 安全保护性能 (7)5.12 电池完全完全充电后内阻 (8)6 运输、贮存 (8)7 安全规程及使用说明 (8)8 特殊要求 (8)9 PCB原理图,电芯基本特性及外形图 (9)10 电芯充放电曲线图11 成品电池尺寸图产品型号1 适用范围本规格书适用于可充电锂离子电池产品的定义、要求、测试方法、质量评定程序及标志、包装、运输、贮存。
用户请务必严格按照规格书中的测试或使用方法进行测试或使用,如对表中的测试项目或测试方法有异议,请与供应方协商解决2 引用标准下列标准所包含的条文,通过在本规范中引用而构成为本规范的条文。
GB/T 2828-1987 逐批检查计数抽样程序及抽样表(适用于连续批的检查)GB/T 2829-1987 周期检查计数抽样程序及抽样表(适用于生产过程稳定性的检查)GB/T 2900.11-1988 蓄电池名词术语3 定义本规范采用GB/T 2900.11 中规定的术语和下列定义。
18650锂电池组技术规格书
Resistor
SMD 10KΩ±5%
0603
3
YAGEO
5
R8
Resistor
SMD 1MΩ±5%
0603
1
YAGEO
6
R9,R10
Resistor
SMD 5.1KΩ±5%
0603
2
YAGEO
7
R7
合金电阻
P=1W
SMD 10mΩ±5%
2512
1
YAGEO
8
R6
Resistor
SMD 51Ω±5%
过放电解除电压(备有休眠的IC,需
VDD-VM电压差在1.3V以上才可以恢复)
3.0±0.1V
过流保护
VDET3
过电流检测电压
0.1±0.025V
VDET3
过充电流检测电压
/
IDP
过电流保护电流
8.0~11.0A
IDP
过充电流保护电流
/
tVDET3
检测延迟时间
10.0±5.0mS
保护解除条件
Cut load
全新进口索尼18650/2600MAH电芯
组合方式
三串六并
电池容量
15.6AH
电池组平均电压
11.1V
电池组输出电压范围
9V→12.6V
电池组充电电压范围
12.6V→12.8V
外形尺寸
约35*185*68mm
要求电池组输出功率
25W
电池组标准充电电流
0.2-0.5C
锂电池保护功能部分
电池组具有充放电电流.电压保护电路,短路保护
0603
1
YAGEO
三星18650 2200mAh规格书
SPECIFICATION OF PRODUCTfor Lithium-ion Rechargeable CellModel : ICR18650-22FMAug, 2008Samsung SDI Co., Ltd.Battery Business DivisionHistory of Revisions1. ScopeThis product specification has been prepared to specify the rechargeable lithium-ion cell ('cell') to be supplied to the customer by Samsung SDI Co., Ltd.2. Description and Model2.1 Description Cell (lithium-ion rechargeable cell)2.2 Model ICR18650-22FM3. Nominal SpecificationsNote (1): If the cell is kept as ex-factory status(50% of charge),the capacity recovery rate is more than 80%.4. Outline DimensionsSee the attachment(Fig. 1)5. AppearanceThere shall be no such defects as scratch, rust, discoloration, leakage whichmay adversely affect commercial value of the cell.6. Standard Test Conditions6.1 Environmental ConditionsUnless otherwise specified, all tests stated in this specification areconducted at temperature 25±5℃and humidity 65±20%.6.2 Measuring Equipment(1) Ammeter and VoltmeterThe ammeter and voltmeter should have an accuracy of the grade 0.5 or higher.(2) Slide caliperThe slide caliper should have 0.05 mm scale.(3) Impedance meterThe impedance meter with AC 1kHz should be used.7. Characteristics7.1 Standard ChargeThis "Standard Charge" means charging the cell with charge current1100mA and constant voltage 4.2V at 25℃for 3hours.7.2 Standard Discharge CapacityThe standard discharge capacity is the initial discharge capacity of the cell, which is measured with discharge current of 440mA with 2.75V cut-off at 25℃within 1 hour after the Standard charge.Standard Discharge Capacity ≥2150mAh7.3 Initial internal impedanceInitial internal impedance measured at AC 1kHz after Standard charge.Initial internal impedance ≤100mΩ7.4 Temperature Dependence of Discharge CapacityDischarge capacity comparison at each temperature, measured with dischargeconstant current 1100mA and 2.75V cut-off with follow temperature after the standard charging at 25℃.Note: If charge temperature and discharge temperature is not the same,the interval for temperature change is 3 hours.Percentage as an index of the Standard discharge capacity(=2150mAh) is 100%.7.5 Temperature Dependence of Charge CapacityCapacity comparison at each temperature, measured with dischargeconstant current 1000mA and 2.75V cut-off at 25℃after the Standard charge isas follow temperature.Note: If charge temperature and discharge temperature is not the same,the interval for temperature change is 3 hours.Percentage as an index of the Standard discharge capacity(=2150mAh) is 100%.7.6 Charge Rate CapabilitiesDischarge capacity is measured with constant current 440mA and 2.75V cut-offafter the cell is charged with 4.2V as follows.Note: Percentage as an index of the capacity at 25℃(=2150mAh) is 100%.7.7 Discharge Rate CapabilitiesDischarge capacity is measured with the various currents in under table and 2.75Vcut-off after the standard charge.Note: Percentage as an index of the capacity at 25℃(=2150mAh) is 100%.7.8 Cycle LifeEach cycle is an interval between the charge (charge current 1760mA) and thedischarge (discharge current 2200mA) with 2.75V cut-off. Capacityafter 299cycles and plus 1 day, measured under the same condition in 7.2Capacity ≥1500mAh7.9 Storage CharacteristicsCapacity after storage for 30days at 25℃after the Standard charged,measured with discharge current 1100mA with 2.75V cut-off at 25℃.Capacity retention(after the storage) ≥1720mAh7.10 Status of the cell as of ex-factoryThe cell should be shipped in 50% charged state.8. Mechanical Characteristics8.1 Drop TestTest method: Cell(as of shipment or full charged) drop onto the oak-board(thickness:≥30mm) from 4feet height at a random direction 6 times.Criteria: No leakage8.2 Vibration TestTest method: Cell(as of shipment) is vibrated along 2 mutuallyperpendicular axes with total excursion of 1.6mm and withfrequency cycling between 10Hz and 55Hz by 1Hz/min.Criteria: No leakage9. Safety10.1 Overcharge TestTest method: To charge the standard charged cell with 12V and 2200mA at 25℃for 2.5 hours.Criteria: No fire, and no explosion.10.2 External Short-circuit TestTest method: To short-circuit the standard charged cell by connecting positive and negative terminal by less than 50mΩwire for 3 hours.Criteria: No fire, and no explosion.10.3 Reverse Charge TestTest method: To charge reversely the standard charged cell with charge current2200mA for 2.5 hours.Criteria: No fire, and no explosion.10.4 Heating TestTest method: To heat the standard charged cell at heating rate of 5℃per minute up to 130℃and keep the cell in oven for 60 minutes.Criteria: No fire, and no explosion.10. WarrantySamsung SDI will be responsible for replacing the cell against defects or poor workmanship for 15month from the date of shipping. Any other problems caused by malfunction of the equipment or unsuitable use of the cell are not under this warranty.The warranty set forth in proper use, handling conditions described above,and excludes in the case of a defect which is not related to manufacturing of the cell.11. Others12.1 Storage for a long timeIf the cell is kept for a long time(3months or more), It is strongly recommendedthat the cell is preserved at dry and low-temperature.12.2 OtherAny matters that specifications does not have, should be conferred withbetween the both parties.12. PackagingSee Fig.2,Package DrawingFig. 1 Outline Dimensions of ICR18650-22FMUnit : mm Max. 18.4 Max. 65.0Fig 2. Package DrawingProper Use and Handling of Lithium Ion CellsSee before using lithium-ion cellSupplied bySamsung SDIEM1. GeneralThis document has been prepared to describe the appropriate cautions and prohibitions, which the customer should take or employ when the customer usesand handles the lithium ion cell to be manufactured and supplied by Samsung SDIEM in order to obtain optimum performance and safety.2. Charging2.1 Charging currentCharging current should be less than maximum charge current specified inthe product specification.2.2 Charging voltageCharging should be done by voltage less than that specified inthe product specification.2.3 Charging timeContinuous charging under appropriate voltage does not cause any loss ofcharacteristics. However, the charge timer is recommended to be installedfrom a safety consideration, which shuts off further charging at time specifiedin the product specification.2.4 Charging temperatureThe cell should be charged within a range of specified temperatures inthe product specification.2.5 Reverse chargingThe cell should be connected, confirming that its poles are correctly aligned.Inverse charging should be strictly prohibited. If the cell is connectedimproperly, it may be damaged.3. Discharging3.1 Discharging3.1.1 The cell should be discharged at less than maximum discharge currentspecified in the product specification.3.2 Discharging temperature3.2.1 The cell should be discharged within a range of temperatures specified inthe product specification.3.2.2 Otherwise, it may cause loss of characteristics.3.3 Over-discharging3.3.1 The system should be equipped with a device to prevent further dischargingexceeding discharging cut-off voltage specified in the productspecification.(over-discharging)3.3.2 Over-discharging may cause loss of performance, characteristics, ofbattery function.3.3.3 Over-discharging may occur by self-discharge if the battery is left fora very long time without any use.3.3.4 The charger should be equipped with a device to detect cell voltage and todetermine recharging procedures.4. Storage4.1 Storage conditions4.1.1 The cell should be stored within a range of temperatures specifiedin the product specification.4.1.2 Otherwise, it may cause loss of characteristics, leakage and/or rust.4.2 Long-term storage4.2.1 The cell should be used within a short period after charging becauselong-term storage may cause loss of capacity by self-discharging.4.2.2. If long-term storage is necessary, the cell should be stored at lowervoltage within a range specified in the product specification, becausestorage at higher voltage may cause loss of characteristics.5. Cycle life5.1 Cycle life performance5.1.1 The cell can be charged/discharged repeatedly up to times specified inthe produce specification with a certain level of capacity also specifiedin the product specification.5.1.2 Cycle life may be determined by conditions of charging, discharging,operating temperature and/or storage.6. Design of System6.1 Connection between the cell and the battery6.1.1 The cell should not be soldered directly with leads. Namely, the cellshould be welded with leads on its terminal and then be soldered withwire or leads to soldered lead.6.1.2 Otherwise, it may cause damage of component, such as separator andinsulator, by heat generation.6.2 Positioning the battery in the System6.2.1 The battery should be positioned as possible as far from heat sourcesand high temperature components.6.2.2 Otherwise, it may cause loss of characteristics.6.3 Mechanical shock protection of the battery6.3.1 The battery should be equipped with appropriate shock absorbers in order tominimize shock.6.3.2 Otherwise, it may cause shape distortion, leakage, heat generationand/or rupture.6.4 Short-circuit protection of the cell6.4.1 The cell is equipped with an insulating sleeve to protect short-circuit whichmay occur during transportation, battery assembly and /or systemoperation.6.4.2 If the cell sleeve is damaged by some causes such as outside impact,it may cause short-circuit with some wiring inside the battery.6.5 Connection between the battery and charger/system6.5.1 The battery should be designed to be connected only to the specifiedcharger and system.6.5.2 A reverse connection of the battery, even in the specified system,should be avoided by employing special battery design such asa special terminals.7. Battery Pack Assembly7.1 Prohibition of usage of damaged cell7.1.1 The cell should be inspected visually before battery assembly.7.1.2 The cell should not be used if sleeve-damage, can-distortion and/orelectrolyte-smell is detected.7.2 Transportation7.2.1 If the cell is necessary to transport to order place, such as thebattery manufacturer, careful precautions should be taken to avoiddamage of cell.8. Others8.1 Disassembly8.1.1 The cell should not be dismantled from the battery pack.8.1.2 Internal short-circuit caused by disassembly may lead to heat generationand/or venting.8.1.3 When the electrolyte is coming in contact with the skin or eyes,wash immediately with fresh water and seek medical advice.8.2 Short-circuiting8.2.1 Short-circuit results in very high current which leads to heat generation.8.2.2 An appropriate circuitry should be employed to protect accidentalshort-circuiting.8.3 Incineration8.3.1 Incinerating and disposing of the cell in fire are strictly prohibited,because it may cause rupture.8.4 Immersion8.4.1 Soaking the cell in water is strictly prohibited, because it may causemelt of components to damaged to functions.8.5 Mixing use8.5.1 Different types of cell, or same types but different manufacturer's cellmay lead to cell rupture or damage to system due to the differentcharacteristics of cell.8.6 Battery disposal8.6.1 Although the cell contains no environmentally hazardous component,such as lead or cadmium. the battery should be disposed according tothe local regulations when it is disposed.8.6.2 The cell should be disposed with a discharged state to avoid heat generationby an inadvertent short-circuit.8.7 Caution - The Battery used in this device may present a risk of fire or chemical burn ifmistreated. Do not disassemble, heat above 100℃or incinerate. Replacebattery with Samsung SDI battery only. Use of another battery may present a riskof fire or explosion. Dispose of used battery promptly. Keep away from children.Do not disassemble and do not dispose of in fire.8.8 AttachedSystem Pack Quality Guideline8-8-1 The battery pack’s consumption current.- Sleep Mode: Under 250uA.- Shut Down Mode: Under 10uA (under 2.5V).8-8-2 SOC 0%- Any bank voltage in SOC 0% of Pack should be higher than 3.0V.(Discharging Cut-off Voltage)8-8-3 Operating Charging Voltage of a cell.- Normal operating voltage of cell is 4.20V.- Max operating voltage of cell is 4.25V.8-8-4 No continuous charge- Charge cut-off condition : Cut-off Current is higher than 1/20C(Charging method: CC-CV)- Initial recharging condition : Remaining Capacity is lower than 90% or Voltageis lower than 4.10V8-8-5 Pre-charging function- Pre-charge function should be implemented to prevent abnormal high ratecharging after deep discharge.- Pre-charging condition :Operation: less than 3.0VCharging current : Under 150mA/Cell.(Continuous)Pre-charge stop (Normal Charge Start) : All cells reach 3.0V8-8-6 Cell voltage monitoring system.- The system (Charger or Pack) should equip a device to monitor each cellvoltage and to stop charging if a cell imbalance happened.8-8-7 The battery pack should have warning system for over temperature, over voltage, over current, and unexpected events would be harm to system. If battery facesharsh condition such as over temperature, Battery pack should control FET-offdirectly.8-8-8 Mechanical guides.- PCBA and Cell stack should have heat insulation material between them. (Suchas plastic barrier which is giving air isolation or non-thermal conductivematerial.)- B+ and B- wire connection should not be crossed each other. Do not make wirewhich had the voltage difference more than 4.0V get together.- The material such as double sided tape and rubber which are used in batterypack should be verified for its flammabilityHandling Precaution and Prohibitions of Lithium Ion & Lithium Ion PolymerRechargeable Cells and BatteriesInaccurate handling of lithium ion and lithium ion polymer rechargeable battery may cause leakage, heat, smoke, an explosion, or fire.This could cause deterioration of performance or failure. Please be sure to follow instructions carefully.1.1 StorageStore the battery at low temperature (below 20℃is recommended), low humidity, no dust and no corrosive gas atmosphere.1.2 Safety precaution and prohibitionsTo assure product safety, describe the following precautions in the instruction manual of theapplication.[ Danger!]■Electrical misusageUse dedicated charger.Use or charge the battery only in the dedicated application.Don't charge the battery by an electric outlet directly or a cigarette lighter charger.Don't charge the battery reversely.■Environmental misusageDon't leave the battery near the fire or a heated source.Don't throw the battery into the fire.Don't leave, charge or use the battery in a car or similar place where inside of temperature may be over 60℃.Don't immerse, throw, wet the battery in water / seawater.■othersDon't fold the battery cased with laminated film such as pouch and Polymer.Don't store the battery in a pocket or a bag together with metallic objects such as keys, necklaces, hairpins, coins, or screws.Don't short circuit (+) and (-) terminals with metallic object intentionally.Don't pierce the battery with a sharp object such as a needle, screw drivers.Don't heat partial area of the battery with heated objects such as soldering iron.Don't hit with heavy objects such as a hammer, weight.Don't step on the battery and throw or drop the battery on the hard floor to avoid mechanical hock.Don't disassemble the battery or modify the battery design including electric circuit.Don't solder on the battery directly.Don't use seriously scared or deformed battery.Don't put the battery into a microwave oven, dryer ,or high-pressure container.Don't use or assemble the battery with other makers' batteries, different types and/or models of batteries such as dry batteries, nickel-metal hydride batteries, or nickel-cadmium batteries.Don't use or assemble old and new batteries together.[ Warning! ]Stop charging the battery if charging isn't completed within the specified time.Stop using the battery if the battery becomes abnormally hot, order, discoloration, deformation, orabnormal conditions is detected during use, charge, or storage.Keep away from fire immediately when leakage or foul odors are detected. If liquid leaks onto your skin or cloths, wash well with fresh water immediately.If liquid leaking from the battery gets into your eyes, don't rub your eyes and wash them with clean water and go to see a doctor immediately.If the terminals of the battery become dirty, wipe with a dry cloth before using the battery.The battery can be used within the following temperature ranges. Don't exceed these ranges.Charge temperature ranges : 0℃~ 45℃Discharge Temperature ranges : -20℃~ 60℃Store the battery at temperature below 60℃Cover terminals with proper insulating tape before disposal.[ Caution! ]■Electrical misusageBattery must be charge with constant current-constant voltage (CC/CV).Charge current must be controlled by specified value in Cell specification.Cut-off Voltage of charging must be 4.2V.Charger must stop charging battery by detecting either charging time or cur rent specified in Cell’s specification.Discharge current must be controlled by specified value in Cell’s specification.Cut-off Voltage of discharging must be over 2.5V.■othersKeep the battery away from babies and children to avoid any accidents such as swallow.If younger children use the battery, their guardians should explain the proper handling method and precaution before using.Before using the battery, be sure to read the user's manual and precaution of it's handling.Before using charger, be sure to read the user's manual of the charger.Before installing and removing the battery from application, be sure to read user's manual of the application.Replace the battery when using time of battery becomes much shorter than usual.Cover terminals with insulating tape before proper disposal.If the battery is needed to be stored for an long period, battery should be removed from the application and stored in a place where humidity and temperature are low.While the battery is charged, used and stored, keep it away from object materials with static electric chargers.Safety Handling Procedure for the Transporter■Quarantine : Packages that are crushed, punctured or torn open to reveal contents should not be transported. Such packages should be isolated until the shipper has been consulted,provided instructions and, if appropriate, arranged to have the product inspected andrepacked.■Spilled Product : In the event that damage to packaging results in the release of cells or batteries, the spilled products should be promptly collected and segregated and the shippershould be contacted for instructions.Design of positioning the battery pack in application and charger To prevent the deterioration of the battery performance caused by heat, battery shall be positioned away from the area where heat is generated in the application and the charger.Design of the Battery PackBe sure adopting proper safe device such as PTC specified type or model in Cell Specification.If you intend to adopt different safety device which is not specified in Cell Specification, please contact Samsung SDI to investigate any potential safety problem.Be sure designing 2nd protective devices such as PTC & PCM at the same time to protect Celljust in case one protective device is fault.Please contact following offices when you need any help including safety concerns.Samsung SDI Emergency Contact Information■Samsung SDI Headquarter.575 Shin-dong, Youngtong-gu, Suwon, Kyunggi-doTel:(+82)31-210-7114 Fax:(+82)31-8006-3689■Samsung SDI Chonan factory.508, Sungsung-Dong, Chonan City, Chungchongnam-Do, KoreaTel:(+82)41-560-3669 Fax:(+82)41-560-3697■Samsung SDI America office.18600 Broadwick Street Rancho Dominguez CA 90220Tel:(+1)310-900-5205 Fax:(+1)310-537-1033■Samsung SDI Taiwan office.Rm. 3010, 30F., 333, Keelung Rd. Sec. 1, Taipei, TaiwanTel:(+886)2-2728-8469 Fax:(+886)2-2728-8480。
磷酸铁锂电池组48V16A 规格书 蒋合你好
生效日期:2014-06-24 锂离子动力电池产品规格书产品名称:磷酸铁锂电池组产品规格: 48V16Ah(18650)制定审核批准孔永乐任鹏任士界生效日期:2014-06-24目录1. 前言 (3)2. 产品规格及型号 (3)3. 电池组相关参数 (4)4.标准测试条件 (4)5.充放电特性 (5)6. 充放电曲线 (5)7. 注意事项 (6)8. 产品责任 (6)生效日期:2014-06-24 1. 前言本标准描述了磷酸铁锂48V16Ah电池组的外型尺寸、特性、技术要求及注意事项,本标准适用于磷酸铁锂48V16Ah电池组。
2. 产品规格及型号2.1产品规格: 锂离子电池组2.2型号: 16IFR48-16-Y (18650-3.2V-16S10P)2.3相关图片及出线方式(以实物为准)正极输出红色一根14号线线长(500±10)mm威浦WS20系列两芯防水航空接插件(1正2负)负极输出黑色一根14号线线长(500±10)mm生效日期:2014-06-24 3.电池组相关参数项目标准备注标称电压48V典型容量16±0.5Ah 0.2C放电率正常电流15A最大持续放电电流30A <2min最大瞬间放电电流120±20A 10±5ms放电截止电压约40V充电电压57.6±0.1V充电方式CC/CV,请用专用充电器充电充电电流≤10A内阻≤100mΩ放电正极和放电负极两端之间内阻工作温度范围充电0℃~+45℃放电-20℃~+60℃当环境温度大于45℃时,请注意通风散热存储温度范围0℃~40℃(容量80%)长期存储温度在 15℃~25℃储存使用环境湿度5%≤RH≤85%包装材质PVC重量7.2±0.1Kg外部尺寸(385±2)*(150±2)*(75±2)mm保护功能过充保护、过放保护、过流保护、均衡功能、温度保护4.标准测试条件测试电池组必须是本公司出厂时间不超过一个月。
比克N18650CNP锂离子电池规格书说明书
锂离子电池规格书SpecificationForLithium-ion Rechargeable Battery电芯型号: N18650CNPCell Type : N18650CNPDocument No P/PR03/PB-D-N18650CNP revised date 2018-5-3 Version A/01 Pages 13 Approved Checked Designed李艳斌邱沫马奇会Contents 目录1Preface前言2Definition定义2.1Standard charge method 标准充电方式2.2Standard discharge method 标准放电方式2.3Nominal capacity 标称容量3Cell type and dimension电芯型号及尺寸3.1Description and type 电芯说明及型号3.2Cell dimension电芯尺寸4Battery characteristics电池特性5Technical requirements技术要求5.1Battery usage conditions 电池使用环境5.2Battery testing conditions 电池实验环境5.3Requirement of the testing equipment 测量仪表要求5.4Electrochemical characteristics 电化学特性5.5Environmental characteristics 环境适应性能5.6Safety characteristics 安全性能6Package picture包装图片7Shipment出货8Warranty质量保证9Storage and shipment requirement存储及运输要求10Warning and cautions in handling the lithium-ion battery电池使用时警告事项及注意事项11The restriction of the use of hazardous substances有害物质控制要求12Contact information联系方式13Version history修订履历1Preface前言This specification describes the type, dimension, performance, technical characteristics, warnings and cautions of the lithium-ion rechargeable battery. The specification only applies to N18650CNP fresh batterys supplied by Shenzhen BAK Power Battery Co., Ltd.本标准描述了圆柱型锂离子电池的型号、尺寸、特性、技术要求及注意事项。
规格书SZNS18650-2200mAh
电池 按 4.3 的测试方法进行充放电 300 周,其中 1 周包
含 1 个充电和放电。
Cells shall be charged per 4.1 at 25℃±2 ℃ and discharge per
4.2 at the following temperatures
在 25℃±2℃ 按照 4.1 放式充满电,在如下的温度下按 4.2 放式放
深圳市卓能新能源股份有限公司
锂离子电芯规格书
Specification For
Lithium-ion Rechargeable Cell
电芯型号:SZNS18650-2200(带 PTC) Cell Type:SZNS18650-2200(with PTC)
Document NO Version Designed
Max. Charge Voltage 最大充电电压
Max.charge current 最大充电电流
Standard Discharge (Refer to 4.2) 标准放电
Fast Discharge (refer to 4.3) 快速放电(参照 4.3) Max.discharge current 最大放电电流 Approx Weight 大约重量 Internal resistance 内阻 Diameter 直径
标准放电方式: “Standard Discharge” shall consist of discharging at a constant current of 0.2C (440mA) to 2.75V. Discharging is to be performed at 25℃±2 ℃ unless otherwise noted (such as capacity versus temperature ) 指在 25℃±2 ℃环境下,0.2C(440mA)恒流放电至 2.75V。 4.3 Fast charge/discharge method 快速充放电方式 Tested at 25℃±2 ℃ Cell shall be charged at constant current of 0.5C(1100mA) to 4.20Vwith end current of 22mA. Cells shall be discharge at constant current of 0.5C(1100mA) to 2.75V. Cells are to rest 10 minutes after charge and 20minutes after discharge. 在 25℃±2 ℃,0.5C(1100mA)恒流恒压充电到 4.20V,截止电流为 22mA,搁置 10min,然后 0.5C(1100mA)放电到 2.75V,搁置 20min。
深圳市中美通用有限公司锂电池组规格书说明书
Lithium ion Battery Pack Specification锂电池组规格书MODEL/型号: INR18650-14.8V30AHSN: GEB INR18650 4S12PPrepared By/Date 编制/日期Checked By/Date审核/日期Approved By/Date批准/日期21/09/04 张平21/09/04程建波21/09/04周腾飞Customer Approval 客户批准Signature确认Date日期Company Name:公司名称:Company Stamp:客户印章:--- 保密文件 ---Amendment Records (修正记录)Edition (版本)Description(记述)Prepared by(编制)Approved by(批准)Date(日期)A0 First Edition 2022-11-041.Scope(适用范围)This specification is applied to the reference battery in this Specification that manufactured by General Electronics Technology Co., Ltd.本说明书适用于本书中所提及的深圳市中美通用科技有限公司制造的电池。
2.Adopted Standard(引用标准)National Standard CQC1126-2017 “technical specification for lithium-ion battery pack used in solar street lamps” of CQC.中国质量认证中心CQC1126-2017《太阳能路灯用锂离子电池组技术规范》。
3.Product Specification(产品技术规格)Table 1 (表1)No.(序号) Item(项目)Parameter(参数) Remark(备注)1 Nominal Voltage(标称电压)14.8V 单节3.7V2 Rated Capacity(额定容量)Typical(标称容量)30500mAh Standard discharge(0.3C) afterStandard charge(0.2C)(0.2C标准充电后0.3C标准放电)Minimum(最小容量)30000mAh3 Charging Voltage(充电电压) 16.8V4 Charging Mode(充电方式)C.C/C.V.(恒流/恒压方式)Constant Current/Constant Voltage(恒流/恒压)5 Voltage at end ofDischarge(放电终止电压)11.2V Discharge Cut-off Voltage(放电截止电压)6 Rated Charge Current(额定充电电流)≤6ACharging Current 6A(充电电流6A)7 Maximum ContinuousCharge Current(最大持续充电电流)≤10ANot more then 1 hours(不超过1小时)8 Internal Impedance(内阻)<150mΩ9 Rated Discharge Current(额定放电电流)≤8ADischarging Current 8A(放电电流8A)10 Maximum ContinuousDischarge Current(最大持续放电电流)≤10ANot more then 1 hours(不超过1小时)11 Overcharge Voltage(过充电保护电压)4.25±0.025V /Cell(可调)Single string voltage(单串电压)12 Over Discharge Cut OffVoltage(过放电保护电压)2.7±0.08V /Cell(可调)Single string voltage(单串电压)Continuous the table 1 (续表1)13 Over Current(过流保护)60±5A(瞬间最大过流保护)5ms—30ms14 Short Circuit(短路保护)Detection condition(保护条件)Exterior short circuit(外部电路短路)Release condition(保护解除条件)Cut short circuit(断开短路电路)15 Operating ConsumptionCurrent of PCB(保护板工作消耗电流)≤30μASingle string of cell(单串电池)16 Cell balance Current(均衡电流)50±5mA17 Bleed Start Point(均衡开启电压)4.15±0.025V18 BMS Size(保护板尺寸)60*33*10mm19 Operation TemperatureRange(工作温度范围)Charge(充电): -20~60℃60±25%R.H.Bare Cell(电池储存湿度范围)Discharge(放电): -20~60℃20 Storage TemperatureRange(储存温度范围)Less than 1 year: -20~25℃(小于一年:-20~25℃)60±25%R.H.at the shipment state(出货状态时的湿度范围)less than 3 months: -20~40℃(小于3个月:-20~40℃)Less than 7 day : -20~65℃(小于7天:-20~65℃)21 The battery packDimension(电池组尺寸)Length/长度:197±3MMInitial Dimension(初始尺寸)Width/宽度: 88±3MMHigh/高度:70±3MM22 Cells(电芯)18650-2500mah Li(NiCoMn)O2(三元锂)23 Connection Type(组合方式)4S12P(4串12并)Cells Without Plastic Bracket(内部不带电芯支架)24 Weight(重量)≤2.4Kg25 Waterproof grade(防水等级)/26Cycle Life(循环寿命)Carry Out 500 cycle(循环500次)Higher than 80% of the InitialCapacities of the Cells(剩余电量大于初始容量的80%)3.Performance And Test Conditions (电池性能及测试条件)3.1 Standard Test Conditions(标准测试条件)Test should be conducted with new batteries within one week after shipment from our factory and the cells shall not be cycled more than five times before the test. Unless otherwise specified, test and measurement shall be done under temperature of 23±3℃and relative humidity of 45~85%. If it is judged that the test results are not affected by such conditions, the tests may be conducted at temperature 15~30℃and humidity 25~85%RH.测试必须使用出厂时间不超过一个星期的新电池,且未进行过五次以上的充放电循环。
18650(1100)中文版规格书
1.适用范围本规格书规定了深圳市汇业电子有限公司向客户提供的18650 (1100mAh)圆柱型锂离子电池的技术参数及测试标准。
2.种类型号2.1种类:圆柱型锂离子二次电池2.2 型号:1 86501-1100mAh3.参考标准此规范参考GB/T18287-2000、UL1642及IEC61960—1:2000等技术标准规范编制。
4. 注意事项4.1在测试或使用电池之前,请仔细阅读本规格书,以防止不当操作引起电池功能失效、发热、漏液、起火甚至爆炸;4.2 对电池进行充放电测试时,请使用锂离子电池专用测试设备,严禁使用普通恒流恒压源等不能限压限流设备对电池进行充放电,以避免电池被过充过放而引起电池功能失效或发生危险;4.3对电池充放电或将电池装入设备时,注意不要将电池正负极反置,否则将会使电池发生过充过放,导致电池严重失效甚至发生爆炸等危险;4.4不要直接对电池进行焊接,严禁对电池进行分解;4.5不要把电池同项链、发夹、硬币或螺丝等金属品一起放在兜中或包中,也不要把电池同上述物品一起储存,严禁用金属等导电材料直接连接电池正负极而使电池发生短路;4.6禁止敲击、抛掷或踩踏电池,更不要将电池放入洗衣机或高压容器内;4.7请勿将电池靠近热源,如火、加热器等,不要在烈日下或在温度超过60℃的条件下使用或存放电池,否则可能会引起电池发热、起火及功能失效等;4.8不要将电池弄湿或将电池投入水中,暂不使用时,请放置在低温干燥的环境中;4.9使用、测试或存放电池时,如发现电池有变热、散发气味、变色、变形或其它反常时,请立即停止使用或测试,设法隔离电池并远离;4.10如电池漏液并不慎将电解液溅入眼睛,不要揉擦你的眼睛,立刻用干净的水清洗,严重时请去医院就医,如皮肤或衣物溅上电解液,则需马上用清水清洗干净。
5.6. 测试条件7. 外观外表清洁,无机械损伤、漏夜、锈蚀;另表面有必须的产品标识。
8. 性能9. 包装电池在包装时需处于半充满状态,包装箱外应标明产品名称、型号、标称电压、数量、毛重、出厂日期及相应等级的内阻、容量。
单体电芯18650-2200-3.7V 规格书
Temperature: 20℃~25℃
Relative Humidity:60%±25% R.H.
4.3CellElectrical characteristics/电气特性
No
Items/项目
Test Method and Condition/测试方法及条件
容量保持
≥80%
4
Temperature Dependence ofdischargecapacity(放电温度特性)
Cells shall be charged per3.3.1anddischarged@0.2C5A to3.0volts.Except to be discharged at temperatures per Table3. Cells shall be stored for3hours at the test temperature prior to discharging and then shall be discharged at the test temperature. The capacity of a cell at each temperature shall be compared to the capacity achieved at 23ºC and the percentage shall be calculated. .
本说明书只适用于描述本规格书中相关的产品以及优贝特科技有限公司提供的电池。
2Model/型号:18650
3Cell Specification/电芯产品规格
No.
Items/项目
Specifications/规格
Remark
备注
比克 2600mAh 18650锂离子电池规格书
3.0 ±0.05 V
1C when T≥10℃ 0.2C when 10℃>T≥0℃
2C when T≥0℃ 1C when 0℃>T≥-10℃ 0.5C when -10℃>T≥-20℃
Charge: 0~45℃ Discharge: -20~60℃
充电时:0~45℃ 放电时:-20~60℃
Maximum allowable charge and discharge cell surface
This spec manual is the enterprise standard of BAK, without authorization, any pirate or circulation is prohibited. Page1/9
1 preface 前言
This specification describes the type and dimension, performance, technical characteristics, warning and caution of the lithium ion rechargeable cell. The specification only applies to C18650CC cell supplied by Shenzhen BAK Li-Ion Battery Co., Ltd. 本标准描述了圆柱型锂离子电芯的外型尺寸、特性、技术要求及注意事项。本标准适用于深圳市比 克电池有限公司生产的圆柱型 C18650CC 锂离子电芯。 2 Definition 定义 2.1 Rated capacity: 标称容量: Rated capacity Cap=2600mAh. Under 22.5±2.5℃, the capacity obtained when a cell is discharged at 5-hours rate to voltage 3.0 V,which is signed Cap, the unit is mAh.。 标称容量 Cap=2600mAh,指在 22.5±2.5℃环境下,以 5 小时率放电至终止电压 3.0 V 时的容量. , 以 Cap 表示,单位为毫安培时(mAh)。
18650F2P-2000mAh新版规格书(中文)
创明新能源股份有限公司锂离子二次电池规格书高能倍率圆柱型电池CMICR18650F2P-2000mAh编制审核批准宇妍赵悠曼程建良2013-09-18发布2013-09-18生效1.适用范围本规格书规定了创明新能源股份有限公司向客户提供的CMICR18650F2P(2000mAh)圆柱型锂离子电池的技术参数及测试标准。
该参数及标准的拟定,主要参照GB/T18287-2013《移动电话用锂离子蓄电池及蓄电池组总规范》。
2.型号类别2.1类别:圆柱型锂离子二次电池2.2型号:CMICR18650F2P-2000mAh3.基本规格及性能3.1容量标称容量:2000mAh(0.2C放电至3.0V)最低容量:1950mAh(0.2C放电至3.0V)3.2标称电压 3.6V3.3电池内阻≤20mΩ3.4放电终止电压 3.0V3.5充电上限电压4.20±0.05V 3.6标准充电电流0.2C3.7快速充电电流1C3.8标准放电电流0.2C3.9最大持续放电电流10C3.10最大瞬间放电电流20C(<200ms) 3.11电池重量44.0±1g3.12最大尺寸直径(φ):18.6mm 高度(H):65.3mm3.13工作温度充电:0~45℃;放电:-10~60℃3.14贮存温度1个月内:-5~45℃6个月内:0~45℃4.测试条件实验和测量要在标准温度(23±2)℃及标准湿度(65±20)%的条件下进行。
4.1标准充电0.2C恒流恒压充电(CC/CV)至上限电压4.20+/-0.05V,然后以0.02C电流截止;4.2标准放电以0.2C恒流放电至3.0V电压截止5.性能5.1电性能项目测试程序标准5.1.1标称电压电池按4.1充满电后,按0.2C放电过程的平均工作电压. 3.6V 5.1.2放电性能电池按4.1充满电后,以0.2C恒流放电到3.0V。
≥292min5.1.3循环寿命常规寿命在环境温度23±2℃的条件下,以0.5C先恒流充电至上限电压4.20+/-0.05V,再恒压充电至0.02C截止电流;搁置10min后以1C放电至3.0V,放电结束后搁置10min后进行下一个循环,直至连续两次放电容量为首次的80%,则认为寿命终止。
比克18650C4规格书
capacity capacity
at at
1.0C 0.2C
≥
90%
;
1.0C放电容量 0.2C放电容量
≥
90%
能
discharge discharge
capacity capacity
at at
2.0C 0.2C
≥
80% ;
2.0C放电容量 0.2C放电容量
≥
80%
;
Cycle life 5.1.2 循环寿命
Discharge capacity of 300th cycle Original discharge capacity
≥
80%
;
第300次循环的放电容量 初始放电容量
≥
80%
High-Low
discharge capacity at -10O C discharge capacity at 25O C
Recommended charge and discharge cell body temperature 充放电过程中电芯表面的建议温
度
1C
2C when T≥0ºC 1C when 0ºC>T≥-10ºC 0.5C when -10ºC>T≥-20ºC
Charge: 0~45℃ Discharge: -20~60℃ 充电时: 0~45℃ 放电时:-20~60℃
Manufacture Year 排产年份
For example: 7 means 2007 7 代表 2007 年
Manufacture month 排产月份 A means January ,B means February…. L means December A 代表 1 月,B 代表 2 月…. L 代表 12 月
HYLC18650-2200mAh圆柱低温锂电池规格书
Operating
10
temperature
工作温度
11
Storage temperature 储存温度
440mA
2.5V
Charging: 0℃~45℃
充电:
0℃~45℃
Discharging:-40℃~60℃
放电:
-40℃~60℃
-10℃~ +45℃
12
Cell weight 电芯重量
Approx:44.2g 约:44.2g
2) Put the cell into -40±2℃ high temp oven for 4 hours and discharge at 440mA for 5 mins and then change to 220mA to 2.5V at this temperature.
Initial capacity 初始容量 70%
3 Temperature 高温放电
discharge at 0.2C CC to 2.5V at the high temperature. 在 初始容量 90% 60±2℃的高温箱中恒温 2h,在该温度下 0.2C 恒流放电至 2.5V。
1) Standard Charge 标准充电
4
Discharging at Low Temperature
Initial Capacity voltage after standard charge.
2
初始容量
该容量是指标准充电后,0.2C 放电至 3V 截止电压所放
出的容量。
Criteria ≥ 2.2Ah
Discharging at 1) Standard Charge 标准充电
High
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
6过流保护功能:当V-端电压达(0.15±0.015V)时,保护电路会在5-15ms内迅速动作,切断通路,实现过流保护。
7过放保护恢复电压:在常温常压下,将电池连接到水泥电阻负载放电,当电流突然变为零时,断开负载,电池立即恢复输出,此时,只需将充电电源电压调至比电池电压高0.1V即可对电池进行充电。
TSSOP-16
1
SEIKO
2
Q3,Q4
Silicon MOSFET
AO4407
SO-8
2
AOS
3
R1,R2,R3
Resistor
SMD 510Ω±5%
0603
3
YAGEO
4
R4,R5,R11
Resistor
SMD 10KΩ±5%
0603
3
YAGEO
5
R8
Resistor
SMD 1MΩ±5%
0603
0.1±0.025V
VDET3
过充电流检测电压
/
IDP
过电流保护电流
8.0~11.0A
IDP
过充电流保护电流
/
tVDET3
检测延迟时间
10.0±5.0mS
保护解除条件
Cut load
断开负载
保护板最大持续电流
≤4.5A
短路保护
保护条件
外部电路短路
TSHORT
检测延迟时间
100~600uS
保护解除条件
12.6V→12.8V
外形尺寸
Байду номын сангаас约35*185*68mm
要求电池组输出功率
25W
电池组标准充电电流
0.2-0.5C
锂电池保护功能部分
电池组具有充放电电流.电压保护电路,短路保护
二、电气特性
项目
符号
详细内容
标准
过充保护
VDET1
过充电检测电压(保护电压)
4.25±0.05V
过充电检测延迟时间
1.0±0.5S
2、将锂电池与保护板按接线图连接,当电池电压处于过充电压与过放电压之间,并对P+,B-充电1秒钟后,P+与B-的输出电压为电池电压。
3电池过充保护功能:在P+与B-之间加上充电器,对电池充电,电池电压充到过充检测电压时,保护电路动作,切断充电通路,实现过充保护。
4电池过放保护功能:在P+与B-之间接上负载让电池放电,当电池电压下降到过放电压时,保护电路动作,关断放电通路,实现过放保护。
上海艾九能源科技有限公司
电池组技术规格书
型号:AJ-11.1V/15.6AH
生产日期:2011-11-03
一、电池主要参数:(具体可根据客户要求设计)
电池型号
全新进口索尼18650/2600MAH电芯
组合方式
三串六并
电池容量
15.6AH
电池组平均电压
11.1V
电池组输出电压范围
9V→12.6V
电池组充电电压范围
断开短路电路
内阻
RSS
主回路通态电阻
RSS≤65mΩ
消耗电流
IDD
工作时电路内部消耗
30.0μA Max
零 V 充电
OV
向0 V电池充电(电芯电压最小1.7V)
允许
4 Parts list主要元件清单
NO.
元件编号
元件名称
元件规格
封装式
数量
厂商/备注
1
U1
Batteryprotection IC
S8254AANFT-TB-G
1
YAGEO
6
R9,R10
Resistor
SMD 5.1KΩ±5%
0603
2
YAGEO
7
R7
合金电阻
P=1W
SMD 10mΩ±5%
2512
1
YAGEO
8
R6
Resistor
SMD 51Ω±5%
0603
1
YAGEO
9
C1,C2,C3
Capacitor
SMD 0.22μF
0603
3
YAGEO
10
C5,C6
VREL1
过充电解除电压
4.15±0.05V
最大充电电流
≤4.5A
过放保护
过放电检测电压(保护电压)
2.5±0.08V
tVDET2
过放电检测延迟时间
100±50mS
VREL2
过放电解除电压(备有休眠的IC,需
VDD-VM电压差在1.3V以上才可以恢复)
3.0±0.1V
过流保护
VDET3
过电流检测电压
Capacitor
SMD 0.1μF
0603
2
YAGEO
11
C4
Capacitor
SMD 2.2μF
0603
1
YAGEO
12
PCB
Print Circuit Board
I-2040
52*16*1.2mm
1
九和咏
5 、线路板原理图
6、顶层线路板元件位置图
六、功能与说明
1、电池组的输出为两根线(红“+”黑“—”)。