常用告警说明(诺西)

合集下载

常用告警说明(诺西)

常用告警说明(诺西)
序号 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41
29 36 39 28 30
告警 VSWR minor alarm(1838) Failure in optical RP3 interface(3030) Configuration error: Not enough HW for LCR(3070) Connection lost Failure in replaceable baseband unit(3003) VSWR alarm(1837) Baseband bus failure(3020) RF module failure(3010) System module failure(3000) Temperature alarm(3040) Fan failure(3050) Fan failure during fan test(3050) BTS reference clock missing(3080) BTS reset required(4001) Failure In Optical Interface 1(3012) Failure In Optical Interface 0(3012) BTS is uncommissioned(4030) Incompatible SW version detected Commissioning error: Invalid Configuration file(3060) SW fallback(4082) Transport layer connection failure in S1 interface(6202) VSWR major alarm(1837) TX failure in MIMO(4003) BTS master clock tuning failure(1818) BTS synchronization is missing during startup(4160) BTS time not corrected Cell configuration data distribution failed(6253) Error in file server during SW download GPS Receiver alarm: Control Interface not available(4011) GPS Receiver alarm: EEPROM segments status(4126) NE disconnected before upload finished PPS reference clock missing in startup(4153) S1 interface setup failure(6308) Configuration error: Unit initialization failure(3070) Firmware SW mismatch(2056) Parallel RP3-01 link length mismatch(4072) TD-SCDMA minor alarm(4179) BTS internal SW management problem(3090) Cell power failure(4090) Configuration error: Unknown HW resource(3070) RF Loss of secondary optical interface(1930) System module failure F Failure In Optical Interface RRU optical/eletrical module absence 1(3012) RF BB bus connection transmission error(1906) Validation of signed file failed(4145) Failure in optical RP3 interface Unit blocked High memory consumption(6502) Failure In Optical Interface Abnormal CPRI interface to next hop 1(3012) 1935转速高 1932、33风扇坏

诺西基站典型故障处理资料

诺西基站典型故障处理资料
总之,7745掉话告警的原因非常多,它不像天馈告警或风扇告警那么容易找 出问题所在,特别是非硬件方面的原因导致的掉话告警更多,所以在处理此 告警时要和其他部门人员如网优、BSC等多沟通。
/ 2018/10/19
掉话故障处理流程
7745掉话告警

用SITEMASTER测试天馈的 驻波比和回驳损耗是否正常 是 检查载波、连线、合路器、基 带单元等,对各种板件逐个进 行排查,看有无问题板件 无 查看有无传输类告警 特别是误码 无 看是否有干扰,确定哪几块载 波并和其它载波进行对调,看 干扰是否消失 否 报给网优并协助其找出干 扰源,一般干扰消除后告警 自动消失 是 观察7745告警等基站起来 一小时后是否消失 否 是 恭喜 有 通知传输组并协助处理好 传输问题后再观察 掉话告警是一个有很多种原 因的告警,此流程主要是从 硬件故障这个角度来写的, 但在处理此告警的过程中, 还有很多其它非硬件的因素 需要考虑在内,所以在排除 硬件故障以后如果告警还在, 则需网优的大力支持。 如频点、邻区、功率控制 方位角、俯仰角、地势地貌、 盲区较多等都可能引起掉话 告警。 有 更换故障单元再进行观察 进行故障定位,处 理好天馈后再观察
报给网优,请其检查参数 频点、相邻小区情况等
/ 2018/10/19
二、时钟故障
告警号: 7601 告警内容: 7601、Difference between PCM and base station reference. frequency
/ 2018/10/19
二、时钟故障
告警说明: 7601是ULTRASITE站型的时钟告警
/ 2018/10/19
1
INSTALLATION GUIDE EDGE/BTS 8+8+8 WBC 4:1

诺西eNodeB常见故障处理说明书

诺西eNodeB常见故障处理说明书

诺西eNodeB常见故障处理说明书诺西常见故障标准化处理说明书1 诺西Flexi BTS 7650告警处理<告警名称>BASE STATION FAULTY<处理方法>按照故障可能的原因分类,分别列出处理方法如下:1.1 BTS Blocked详细信息Fault name:BTS Blocked(0050)问题描述基站被手动闭锁,系统会上报此告警,需要从site manager登录基站并解锁,解锁过程系统会自动重启基站。

处理方法如图所示,用site manager登录基站后,点击unblock BTS解锁基站,基站重启后告警会自动消除。

1.2 BTS internal SW management problem详细信息Fault name:BTS internal SW management problem(3090)问题描述这个告警的原因是系统检测到文件或者软件错误,可能原因比如远程下发基站参数或者升级软件,但中间的防火墙禁掉某些端口导致基站接收到的文件错误等处理方法1.重启基站;2.重新升级基站软件版本;1.3 Baseband Bus failure详细信息Fault name:Baseband Bus failure(3020)问题描述这个告警的原因是系统检测基站内部基带总线有异常处理方法1.远端重启基站;2.进站检查故障的硬件,尝试调换连线来定位故障位置,更换故障的硬件;1.4 System Module failure详细信息Fault name:System Module failure(3000)问题描述这个告警的原因是系统检测基站系统模块有异常处理方法1.远端重启基站;2.进站检查故障的硬件,尝试调换连线来定位故障位置,更换故障的硬件;1.5 Incompatible SW version detected详细信息Fault name:Incompatible SW version detected(0023/0024)问题描述这个告警的原因是系统检测软件版本不匹配,一般是在硬件更换后产生此告警处理方法新安装或者刚刚完成排障被BBU新检测到的RRU及其他模块,由于没有跟BBU 一起升级,会产生此告警,只要在连接正常的情况下,重新升级基站版本然后重启基站即可,注意RRU 完成升级之后,如果没有配置对应的小区数据,需要手动添加数据配置到该RRU 上。

诺西W_RNC常见告警列表及处理方法

诺西W_RNC常见告警列表及处理方法
BTS与RNC间的维护管理连接中断
基站AAL2链路激活失败 RNW数据库读取或写入失败 小区不工作 HSDPA配置失败
小区配置参数冲突(RNC-BTS之间)
小区HSDPA不可用 基站测量失败 基站自动恢复进程正在进行 小区HSUPA不可用 基站数据配置错误 HSUPA配置失败 基于D-NBAP链路的IP丢失 基站自动恢复进程失败
61171 synchronization on unit $U, interface $IF
61028 LOF on unit $U, interface $IF LOS on unit $U, ethernet
61029 interface $IF Loss of IMA frame on unit $U,
61170 interface $IF
61152 RDI on unit $U, interface $IF BEATING WCDMA BTS
7740 ALARM FAILURE IN WCDMA WBTS
7750 O&M CONNECTION
重要 重要 重要 重要 次要 重要 重要 次要 重要 紧急 重要 重要 重要
告警级别 紧急
告警代码
告警内容
7650 BASE STATION FAULTY
基站故障
重要
BASE STATION 7651
OPERATION DEGRADED 基站性能下降
次要
BASE STATION 7652
NOTIFICATION 基站提示
紧急
7653 CELL FAULTY 小区故障(退服)
1.检查系统模块与射频模块的连线 2.重启基站 3.更换故障射频模块 是
1.检查环境温度是否过高或过低 2.重启产生告警的模块 3.更换产生 否

诺西TD-NodeB相关告警处理方法总结

诺西TD-NodeB相关告警处理方法总结

所有小区退服小区被闭塞RNC上执行DSP CELL查看该小区状态小区配置数量不一致1. 该站点NODEB侧和RNC侧小区配置数量不一致,导致小区退服;2. NODEB侧无相关告警;3. 导致RNC侧看到有小区未建立。

E1/T1告警指示信号传输的物理层有问题E1/T1 远端告警传输的物理层有问题E1/T1信号丢失告警传输的物理层有问题E1/T1线路AIS告警传输的物理层有问题E1/T1帧失步告警传输的物理层有问题E1/T1环回故障传输的物理层有问题E1/T1高误码率门限告警传输的物理层有问题E1/T1高误码率告警传输的物理层有问题IMA组配置失败告警传输的链路层有问题IMA/UNI链路信元定界丢失告警传输链路层有问题IMA链路帧失步告警传输链路层有问题IMA链路延迟失步传输链路层有问题IMA组内激活链路数不足告警传输链路层有问题IMA链路信元定界失步故障传输链路层有问题IMA链路远端接收不可用告警传输链路层有问题FE接口故障FE口没有接网线或FE口故障所致,对使用ATM传输的基站不会有影响BOOTP启动告警传输数据未配置或配置有误所致,OMCH不可用DHCP启动告警传输数据未配置或配置有误所致,OMCH不可用传输配置数据失效告警配置的传输数据无法生效CCP故障CCP不可用SAAL链路断承载在其上的业务传输会有问题AAL2邻节点不可达邻结点不可用,建立在其上的业务传输会有问题PATH故障建立在其上的业务的传输会出问题邻节点无可用资源邻结点不可用,建立在其上的业务传输有问题BBI下行光口断链CPRI闪断故障1. 该告警提示用服人员BBI上的某个光口有光路故障;2. 当光路故障恢复后,该告警自动清除。

传输告警RRU 下行光口断链1. 该告警提示用服人员RRU 上检测到下一级RRU 光路有故障;2. 当光路故障恢复后,该告警自动清除。

RRU 配置但不可用超时1. BBU 启动后,会对RRU 进行配置不可用检测;2. 当RRU 可用后,该检测停止;如果RRU 在配置1小时后,仍然不可用,则上报RRU 配置但不可用超时告警;3. 当RRU 启动并可用后,该告警自动清除。

常用告警说明诺西

常用告警说明诺西

常用告警说明诺西告警是计算机系统中的一个重要功能,可以及时通知管理员或用户有关系统异常、错误或重要事件的信息。

常用告警说明诺西是一个常见的告警信息,下面将详细介绍这个告警及其应对方法。

诺西告警通常指的是来自诺基亚西门子(Nokia Siemens)的网络设备或系统的告警信息。

这些告警一般与网络设备或系统的性能、状态和操作相关。

通过这些告警,管理员可以追踪和解决设备或系统中的问题,以确保网络的正常运行。

诺西告警通常使用标准的告警代码和文本来描述特定的问题或事件。

下面列举了一些常见的诺西告警及其含义:1. ALM-001: 设备离线该告警表示设备当前无法正常连接到网络,可能是由于设备故障、网络故障或配置问题导致的。

管理员应该检查设备的物理连接、设备的配置以及网络的运行状态,以解决该问题。

2. ALM-002: 内存不足该告警表示设备的内存资源已经耗尽或不足。

这可能会导致设备运行缓慢、延迟响应或其他性能问题。

管理员应该检查设备的内存使用情况,并根据需要进行调整或扩容。

3. ALM-003: CPU负载过高该告警表示设备的CPU使用率已经超过了正常范围,可能会导致设备运行缓慢、延迟响应或其他性能问题。

管理员应该检查设备的CPU使用情况,并根据需要进行优化或升级。

4. ALM-004: 温度过高该告警表示设备的温度已经达到了过高的水平,可能会导致设备故障或其他损坏。

管理员应该检查设备的散热系统、通风情况以及环境温度,并采取措施降低设备的温度。

5. ALM-005: 硬盘故障该告警表示设备的硬盘出现了故障或错误,可能会导致数据丢失、读写错误或其他存储问题。

管理员应该检查设备的硬盘状态,并根据需要进行更换或修复。

除了以上列举的告警,诺西系统还可能有其他各种类型的告警,涵盖了设备的各个方面。

管理员应该熟悉不同类型的告警,并了解如何解决它们。

对于诺西告警的处理,管理员通常采取以下几个步骤:1. 确认告警:管理员需要查看告警的具体内容、代码和描述,以了解告警发生的原因和影响。

诺西WCDMA基站常见告警及处理建议

诺西WCDMA基站常见告警及处理建议

诺西WCDMA基站常见告警及处理建议第一篇:诺西 WCDMA基站常见告警及处理建议诺西WCDMA基站常见告警及处理建议紧急告警7650 BASE STATION FAULTY基站故障告警告警附加信息:1、BTS Blocked 基站被锁处理建议:解锁基站2、BTS internal SW management problem 基站内部软件包管理问题处理建议:1.重启基站; 2.更新基站软件包;3.更换故障模块3、Baseband Bus failure基站基带连线故障处理建议:1.检查系统模块与射频模块的连线;2.重启基站;3.升级软件包后观察基站15分钟左右,看基站工作状态;4.更换故障模块4、Failure in optical RP3 interface系统模块与射频模块之间按的接口故障处理建议:此故障多发生于拉远小区,处理步骤:1.检查拉远小区的模块是否有电;2.检查系统模块与射频模块间的光路是否正常;3.更换损坏的光纤或者光电模块;4.重启基站;5.更换故障模块5、No connection to Flexi transport submodule 处理建议:1.重启基站 2.更换故障传输板6、System Module failure系统模块故障基站传输板连接中断处理建议:重启系统模块,如果不能恢复,则更换系统模块7、Temperature alarm温度告警处理建议:1.检查环境温度是否过高或过低;2.查看设备风扇是否工作正常; 2.重启产生告警的模块;3.更换产生告警的模块重要告警7651 BASE STATION OPERATION DEGRADED基站性能下降告警告警附加信息:1、BTS RNC/I-HSPA interface signalling link failure BTS与RNC间的AAL2信令中断处理建议:引发此告警的最常见原因是传输闪断,检查传输状况2、BTS internal SW management problem 基站内部软件包管理问题处理建议:1.重启基站; 2.更新基站软件包; 3.更换故障模块3、BTS reference clock missing 基站参考时钟丢失处理建议:基站上一般设置第1&2条传输为时钟源,如果1&2条传输均断,则触发此告警。

诺西LTE告警手册

诺西LTE告警手册

2014诺基亚通信[LTE 告警处理手册 - RL35] V1.0目录4.1 ENODEB自主复位(765252) (12)4.2同步丢失[单元$U][,接口$IF] (766561059) (12)4.3 光纤接口设备中编码错误<光纤链路/RP3>(76542004) (12)4.4 2M 外部参考时钟丢失(76511899,76521899) (13)4.5 3GPP/AISG 通信管理性关闭(76524142, 76544142) (13)4.6 [用户自定义] (13)4.7 Summing地址不匹配(76512019) (15)4.8 在$U上, 接口$IF AIS (766561151) (15)4.9 天线载波配置失败(76536259,76546259) (15)4.10 天线设备故障(76523100,76533100,76543100,76553100) (16)4.11 天线设备硬件故障 (76521847, 76541847) (16)4.12 天线设备软件丢失(76521848,76541848) (16)4.13天线设备工作异常(76521871,76521872,765218737,76521874, 76551871,76551872,76551873,76551874) (17)4.14 天线(线路)故障(天线线路过流)(76541836) (17)4.15天线线路故障(76534045,76544045) (17)4.16天线性能降级(76544046) (17)4.17天线关闭(76531957,76541957) (18)4.18天线断连(7650476,7651476) (18)4.19单元$U以太网口$IF的自动协商不匹配(766561607) (18)4.20 自动运营证书获取不成功(766561510) (18)4.21小区无法自动恢复(76536277) (19)4.22基站侧和网管侧的配置数据不一致(76524171) (19)4.23 <x>中基带总线配置拒绝(76501811,76511811,76531811,76541811) (19)4.24 基带总线故障(76503020, 76513020,76523020,76533020,76543020,76553020) (19)4.25基带总线消息复用时隙出错(76502057,76512057,76532057,76542057) (20)4.26 基带总线接收错误(Summing设备)(76502016,76512016,76532016,76542016) . 214.27基带总线传输出错(76502017) (21)4.28 BFD会话不可用(入)- BFD$会话终止,出口,$源IP至$目的IP(766561606) (21)4.29 BFD会话不可用(出)- BFD$会话终止,入口,$源IP至$目的IP(766561605) (22)4.30 BFD组$bfdGrpId不可用 (766561022) (22)4.31 boot的配置不一致(76504102,7651402) (22)4.32 基站闭锁(765050) (22)4.33 基站配置错误(没有足够的硬件资源)(76531868) (23)4.34基站配置不支持(76504097,76514097) (23)4.35基站文件错误(丢失或无效)(76501802,76511802,76521802) (23)4.36 ENODEB内部软件管理故障(76503090,76513090,76523090,76543090,76553090) (24)4.37基站未开通(无配置)(76524030) (25)4.38基站主时钟调谐失败(76511818) (25)4.39基站参考时钟丢失(76513080,76523080) (25)4.40基站需要重新启动(766561010) (27)4.41基站需要重启 (76504001, 76514001, 76534001, 76544001) (27)4.42 ENODEB启动时间增加 (76524091) (27)4.43 ENODEB软件下载或者激活失败 (765129,765429,765529,765130,765430,765530) 274.44基站时间不正确 (765226) (28)4.45基站的信任锚过期或将要过期 (766561618) (28)4.46基站供应商定义文件出错 (76506262) (28)4.47连续性检查消息(CCM)错误级别$优先级$p导致$c (766561410) (29)4.48小区闭锁 (765349) (29)4.49小区配置数据下发失败(76536253) (29)4.50小区功率故障 (76536253) (29)4.51小区重配数据分发失败(76536257) (30)4.52配置集成错误(76503060, 76513060, 76523060) (30)4.53通讯失败(76501806, 76511806, 76531806, 76541806) (30)4.54配置错误(76503070, 76513070, 76523070, 76533070, 76543070, 76553070,) (31)4.55配置(射频模块)数据损坏(76541924) (31)4.56降温风扇中断(76524078) (32)4.57降温风扇故障(76521933) (32)4.58(射频模块)降温风扇转速过低(76521934) (32)4.59降温风扇转速过快(76524080) (32)4.60(射频模块)降温风扇过速(76521935) (32)4.61 风扇速度下降 (76524079) (33)4.62 在连接到射频模块的光路上检测到重大比特误差率 (1956) (33)4.63严重的bit转换出错(76526701) (33)4.64 由于$cause原因 CRL更新失败(766561074) (34)4.65 直流电压管理性关闭(76524141,76544141,76554141) (34)4.66检测到对端关闭(766561030) (34)4.67 基站的主时钟和参考频率不同步(76529) (35)4.68 分布站点支持功能未启用(76534076,76544076) (36)4.69 DSP过热(76504101,76514101) (36)4.70(在单元 $U接口 $IF上)误码率超过门限值(766561104) (37)4.71文件下载过程中文件服务器出错(765227) (37)4.72以太网AIS告警(从$ IF接口到$l mac $x接口)(766561411) (38)4.73小区激活失败(76536267) (38)4.74基站和iOMS之间或和第三方工具之间的连接故障(76516261) (38)4.75光接口RP3故障(76503030, 76513030, 76523030, 76533030, 76543030) (38)4.76替换基带单元故障(76503003,76513003) (39)4.77跟踪对话失败(76526263) (39)4.78风扇故障(76523050,76553050) (40)4.79风扇模块故障(76521) (40)4.80风扇性能下降(76520) (40)4.81 未检测到的风扇供应商 (76524073) (41)4.82 操作系统(OSE)致命错误 (7650418,7651418) (41)4.83 (告警诊断)规则文件错误(76501866,76501867) (41)4.84 (系统模块)配置集成错误(76501858) (42)4.85 软件下载中文件损坏(765228,765528) (42)4.86 文件系统读取失败(76504088) (42)4.87 过滤单元操作失败(调谐失败/单元故障/调谐超出范围)(76521840,76531840,76541840,76521841,76531841,76541841,76524043,76534043,76544 043) (42)4.88 FTM上5次错误用户名/密码登录失败(766561500) (43)4.89 闪存操作失败(7651214,7651215,7651216,7651217,7651218) (43)4.90 FPGA软件更新失败(76641928) (44)4.91帧时钟偏离故障(76502014) (44)4.92帧时钟丢失(76531903, 76541903) (44)4.93 FSP处在重置状态(76504068, 76514068) (44)4.94 FSP 过热(76504077, 76514077) (44)4.95 FTM模块重新启动(766561006) (45)4.96 FTM告警转换(766561619) (45)4.97 GPS接收告警:控制接口不可用(76524011) (45)4.98 GPS接收告警:EEPROM无效(76524126) (45)4.99 GPS接收告警: 无存储位置(76524124) (46)4.100 GPS接收告警: 未捕捉到卫星(76524122) (46)4.101 GPS接收机告警:不可靠位置(76524125) (46)4.102 GPS接收机告警:进行测量(76524123) (47)4.103 GTP-U通道失败(76576150) (47)4.104加热单元退服(76521860) (48)4.105高内存占用(76526502) (48)4.106小区配置冲突–同一射频模块配置多种小区类型(A,G,H)(76531856) (48)4.107 小区配置错误–同一个射频模块配置了太多小区(76524000,76534000) (49)4.108小区配置矛盾–小区配置非正式支持(76554044) (49)4.109射频模块配置冲突–同一小区的2个RF模块配置不同的频率(76531857) (49)4.110 软件版本问题(软件版本不兼容 /版本错误)(765023,765024,765123,765124,765223,765224,765323,765324,765423,765424) (49)4.111无线网络参数错误(76506252) (50)4.112射频模块光路上检测到误码率的增长(76541955) (50)4.113 内部 MTU 配置失败(76504025, 76514025) (50)4.114 无效的配置文件(76504036, 76524036) (50)4.115 ENODEB硬件中无效的频率通道(76531807) (51)4.116 IP地址冲突(76524144) (51)4.117 OAM环路告警(766561077) (51)4.118 操作维护链路丢失告警(766561076) (51)4.119 OAM环路告警(766561075) (51)4.120 帧丢失(766561028) (52)4.121 在$U槽上 $IF接口上复帧丢失(766561150) (52)4.122 在单元 $U 接口$IF[以太网] 网卡信号丢失(766561029) (52)4.123 主光纤链路丢失(76534161,76544161) (52)4.124 低噪声放大器故障(76521839,76531839,76541839) (53)4.125 塔放故障(76523120, 76543120) (53)4.126 塔放故障-高于当前窗口(76541834) (53)4.127 塔放故障-低于当前窗口(76541835) (54)4.128主从模块断连(76504019,76514019) (54)4.129 相邻基站数/小区数超出最大值(76526265) (54)4.130 接收器消息路由问题(76502058,76512058,76532058,76542058) (55)4.131 MHA模块故障(76521869,76541869,76521870,76541870) (55)4.132光模块不符合要求(766561050) (55)4.133 RNW参数丢失(76534009) (55)4.135射频模块时钟失锁(76531926,76541926) (56)4.136 模块极度过热(76504071) (56)4.137 邻区检测模糊(76556274) (56)4.138 传输子模块无连接(76503511) (57)4.139与基站所属模块(已配置)连接丢失(765010,765110,765210,765310,765410) 57 4.140 无反馈信号(76541920) (57)4.141 核心网没有分配MME容量 (76526264) (57)4.142 没有检测到(RF)模块的风扇(76521932) (57)4.143 不能使基站总线和<x>同步(76501815,76511815,76531815,76541815) (58)4.144 NTP服务器不可用(766561613) (58)4.145 OIC控制单元缓存溢出(76522011) (58)4.146 光接口数据/控制/以太网缓存溢出(76542007,76542008,76542009,76542010) (59)4.147 光接口故障(76532000,76532001,76542000,76542001) (59)4.148 谐振时钟丢失(76501819) (59)4.149 谐振腔加热失败(76501817) (60)4.150 谐振脉冲丢失(76501820) (60)4.151 发射机过载(76512061) (60)4.152并口 RP3-01链路长度不匹配(76514072,76534072,76544072) (60)4.153 peer system模块连接丢失(76524110) (60)4.154 PHICH功率增大未启用(76556112) (61)4.155 POST测试失败(765069,765169) (61)4.156 射频模块启动自检失败(76531925,76541925) (61)4.157 功率不支持(76534008) (61)4.158 使用相同无线模块的小区功率电平不支持(76534152) (61)4.159 功率反馈由用户远程关闭(76524107) (61)4.160 基站启动过程中PPS参考时钟丢失(76514153) (62)4.161 PPS参考时钟丢失(76511898,76521898) (62)4.162 射频主控模块冲突(76514038) (62)4.163 无线资源关闭(76554057) (63)4.164 单元$u接口$IF上的远端错误指示(766561152) (63)4.166 RET天线控制失灵(76521842,76521843,76521844,76521845,76521846,76541842,76541843,76541844,76541 845,76541846) (64)4.167 射频基带(RF BB)总线配置错误(76521905,76531905,76541905) (64)4.168 射频基带(RF BB)总线连接传输错误(76531906,76541906) (64)4.169 射频基带(RF BB)总线同步错误(76521904,76531904,76541904) (65)4.170 到射频模块的第二光接口丢失(76531930) (65)4.171 射频模块闭锁(76531931, 76541931) (66)4.172射频模块配置失败(76531900,76541900) (66)4.173 射频模块重要文件不存在(76531901,76541901) (66)4.174 射频模块故障(76523010,76533010,76543010) (66)4.175射频模块文件不存在(76541902) (66)4.176射频模块滤波器输入功率丢失(76531910,76541910) (67)4.177 射频模块增益调节失败(76541908) (67)4.178 射频模块退服(76531912,76541912) (67)4.179射频模块功率输出故障(76531918,76541918) (67)4.180 射频模块功率降低(76541927) (67)4.181 RNW参数不匹配(76521896) (67)4.182 在FR模块上检测到RP3路由冲突(76521958) (68)4.183 RP3链路冲突(76514039) (68)4.184 RS485 IUANT 端口故障(76544069) (68)4.185 接收(Rx)通路故障(76531911,76541911) (68)4.186 S1 eNB配置更新失败(76526321) (69)4.187 S1 接口恢复失败(76566317,76576317) (69)4.188 S1接口建立失败(76566308,76576308) (69)4.189 S1 SCTP通路故障(76576204) (70)4.190 光模块硬件故障766561079) (70)4.191 SRAM读出/写入失败(76511875, 76511876) (70)4.192 SRIO链配置拒绝(76504015,76514015) (70)4.193 启动温度过低(76501827) (71)4.194 对某些消息类型Summing不工作(76512059) (71)4.195 Summing服务默认初始化失败(76504092) (71)4.196 Summing服务释放失败(76504081) (71)4.197 软件损坏(76501850,76531850,76541850,76504029,76534029,76544029) (71)4.198 软件回退(76504082, 76514082, 76504083, 76514083, 76504085, 76514085) (71)4.199 SSM(同步以太网)时钟质量低于要求(766561624) (72)4.200 SSM (同步以太网)时钟接收超时(766561623) (72)4.201 RP1接收器同步失败(76502048,76502049) (72)4.202 光接口同步失败<光纤链路/RP3链路>(76532005) (72)4.203 同步丢失 (766561058) (72)4.204 主同步丢失 (76504114) (73)4.205 系统消息广播参数溢出 (76556351) (73)4.206 系统模块故障 (76503000,76513000) (73)4.207 技术日志缓存冻结 (76526450) (73)4.208 温度告警(76503040,76513040,76523040,76543040,76543040,76553040) (73)4.209 温度过低(持续加温) (76531922,76541922,76551922) (74)4.210 基站告警转换<告警名字> (76504026, 76514026, 76524026, 76534026, 76544026, 76554026, 76564026) (74)4.211 ToP主服务器不可用 (766561631) (74)4.212 传输时钟丢失 (76511816) (75)4.213 传输参数丢失 (76511825) (75)4.214 传输质量恶化 (76541921) (75)4.215 传输规则冲突 (76512060) (75)4.216 S1接口传输层连接失败 (76566202,76576202) (75)4.217 X2接口传输层连接失败(76576203) (76)4.218 检测不到传输模块 (766561201) (76)4.219 TWAMP PLR 超出阈值(766561611) (76)4.220 TWAMP RTT超出阈值 (766561610) (76)4.221 MIMO 发射故障(76554003) (76)4.222 发射故障(76531907, 76541907) (77)4.223射频模块极度过热(76531937, 76541937) (77)4.224 (射频)模块温度过高(76551936) (77)4.225 模块闭锁(765248,765348,765448) (77)4.226 模块初始化失败(765012, 76504040, 765112, 76514040) (77)4.227 当前基站软件版本不支持该模块 (765095, 765195, 765295, 765395,765495) (78)4.228 模块软件下载失败 (76506, 76516, 76536, 76546) (78)4.229 单元(FCM/FSP)同步失败(765016,765116) (78)4.230 单元温度过高(76522) (78)4.231模块永久内存损坏(76541923) (78)4.232未能识别的硬件单元(765094, 765194, 765294, 765394, 765494) (79)4.233不支持硬件设备(766561634) (79)4.234签名文件校验失败(76504145,76524145) (79)4.235供应商基站证书即将过期(766561616) (79)4.236驻波比重要告警(76521837,76531837,76541837,76551837) (79)4.237驻波比次要要告警(76521838,76531838,76541838) (80)4.238 X2接口恢复失败(76576303) (80)4.239 X2接口建立失败(76576304) (80)LTE基站故障处理4.1 ENODEB自主复位(765252)4.2同步丢失[单元$U][,接口$IF] (766561059)4.3 光纤接口设备中编码错误<光纤链路/RP3>(76542004)4.4 2M 外部参考时钟丢失(76511899,76521899)4.5 3GPP/AISG 通信管理性关闭(76524142, 76544142)4.6 [用户自定义]4.7 Summing地址不匹配(76512019)4.8 在$U上, 接口$IF AIS (766561151)4.9 天线载波配置失败(76536259,76546259)4.10 天线设备故障(76523100,76533100,76543100,76553100)4.11 天线设备硬件故障 (76521847, 76541847)4.12 天线设备软件丢失(76521848,76541848)4.13天线设备工作异常(76521871,76521872,765218737,76521874, 76551871,76551872,76551873,76551874)4.14 天线(线路)故障(天线线路过流)(76541836)4.15天线线路故障(76534045,76544045)4.16天线性能降级(76544046)4.17天线关闭(76531957,76541957)4.18天线断连(7650476,7651476)4.19单元$U以太网口$IF的自动协商不匹配(766561607)4.20 自动运营证书获取不成功(766561510)4.21小区无法自动恢复(76536277)4.22基站侧和网管侧的配置数据不一致(76524171)4.23 <x>中基带总线配置拒绝(76501811,76511811,76531811,76541811)4.24 基带总线故障(76503020, 76513020,76523020,76533020,76543020,76553020)4.25基带总线消息复用时隙出错(76502057,76512057,76532057,76542057)4.26 基带总线接收错误(Summing设备)(76502016,76512016,76532016,76542016)4.27基带总线传输出错(76502017)4.28 BFD会话不可用(入)- BFD$会话终止,出口,$源IP至$目的IP(766561606)4.29 BFD会话不可用(出)- BFD$会话终止,入口,$源IP至$目的IP(766561605)4.30 BFD组$bfdGrpId不可用 (766561022)4.31 boot的配置不一致(76504102,7651402)4.32 基站闭锁(765050)4.33 基站配置错误(没有足够的硬件资源)(76531868)4.34基站配置不支持(76504097,76514097)4.35基站文件错误(丢失或无效)(76501802,76511802,76521802)4.36 ENODEB内部软件管理故障(76503090,76513090,76523090,76543090,76553090)4.37基站未开通(无配置)(76524030)4.38基站主时钟调谐失败(76511818)4.39基站参考时钟丢失(76513080,76523080)4.40基站需要重新启动(766561010)4.41基站需要重启 (76504001, 76514001, 76534001, 76544001)4.42 ENODEB启动时间增加 (76524091)4.43 ENODEB软件下载或者激活失败(765129,765429,765529,765130,765430,765530)4.44基站时间不正确 (765226)4.45基站的信任锚过期或将要过期 (766561618)4.46基站供应商定义文件出错 (76506262)4.47连续性检查消息(CCM)错误级别$优先级$p导致$c (766561410)4.48小区闭锁 (765349)4.49小区配置数据下发失败(76536253)4.50小区功率故障 (76536253)4.51小区重配数据分发失败(76536257)4.52配置集成错误(76503060, 76513060, 76523060)4.53通讯失败(76501806, 76511806, 76531806, 76541806)4.54配置错误(76503070, 76513070, 76523070, 76533070,4.55配置(射频模块)数据损坏(76541924)4.56降温风扇中断(76524078)4.57降温风扇故障(76521933)4.58(射频模块)降温风扇转速过低(76521934)4.59降温风扇转速过快(76524080)4.60(射频模块)降温风扇过速(76521935)4.61 风扇速度下降 (76524079)4.62 在连接到射频模块的光路上检测到重大比特误差率 (1956)4.63严重的bit转换出错(76526701)4.64 由于$cause原因 CRL更新失败(766561074)4.65 直流电压管理性关闭(76524141,76544141,76554141)4.66检测到对端关闭(766561030)4.67 基站的主时钟和参考频率不同步(76529)4.68 分布站点支持功能未启用(76534076,76544076)4.69 DSP过热(76504101,76514101)4.70(在单元 $U接口 $IF上)误码率超过门限值(766561104)4.71文件下载过程中文件服务器出错(765227)4.72以太网AIS告警(从$ IF接口到$l mac $x接口)(766561411)4.73小区激活失败(76536267)4.74基站和iOMS之间或和第三方工具之间的连接故障(76516261)4.75光接口RP3故障(76503030, 76513030, 76523030, 76533030, 76543030)4.76替换基带单元故障(76503003,76513003)4.77跟踪对话失败(76526263)4.78风扇故障(76523050,76553050)4.79风扇模块故障(76521)4.80风扇性能下降(76520)4.81 未检测到的风扇供应商 (76524073)4.82 操作系统(OSE)致命错误 (7650418,7651418)4.83 (告警诊断)规则文件错误(76501866,76501867)4.84 (系统模块)配置集成错误(76501858)4.85 软件下载中文件损坏(765228,765528)4.86 文件系统读取失败(76504088)4.87 过滤单元操作失败(调谐失败/单元故障/调谐超出范围)(76521840,76531840,76541840,76521841,76531841,76541841,7 6524043,76534043,76544043)4.88 FTM上5次错误用户名/密码登录失败(766561500)4.89 闪存操作失败(7651214,7651215,7651216,7651217,7651218)4.90 FPGA软件更新失败(76641928)4.91帧时钟偏离故障(76502014)4.92帧时钟丢失(76531903, 76541903)4.93 FSP处在重置状态(76504068, 76514068)4.94 FSP 过热(76504077, 76514077)4.95 FTM模块重新启动(766561006)4.96 FTM告警转换(766561619)4.97 GPS接收告警:控制接口不可用(76524011)4.98 GPS接收告警:EEPROM无效(76524126)4.99 GPS接收告警: 无存储位置(76524124)4.100 GPS接收告警: 未捕捉到卫星(76524122)4.101 GPS接收机告警:不可靠位置(76524125)4.102 GPS接收机告警:进行测量(76524123)4.103 GTP-U通道失败(76576150)4.104加热单元退服(76521860)4.105高内存占用(76526502)4.106小区配置冲突–同一射频模块配置多种小区类型(A,G,H)(76531856)4.107 小区配置错误–同一个射频模块配置了太多小区(76524000,76534000)4.108小区配置矛盾–小区配置非正式支持(76554044)4.109射频模块配置冲突–同一小区的2个RF模块配置不同的频率(76531857)4.110 软件版本问题(软件版本不兼容 /版本错误)(765023,765024,765123,765124,765223,765224,765323,765324, 765423,765424)4.111无线网络参数错误(76506252)4.112射频模块光路上检测到误码率的增长(76541955)4.113 内部 MTU 配置失败(76504025, 76514025)4.114 无效的配置文件(76504036, 76524036)。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

告警解释 可能是有事RRU通道问题引起的驻波告警 光口告警,可能是光纤或者光模块问题导致 配置错误:配置文件和实际不匹配/有对应小区可能未接入 断站 BUS线告警,BTS检测异常;可能是高温导致的 可能是有事RRU通道问题引起的驻波告警 BUS线告警,结合历史告警,有几率是光纤模块闪断生成此告警 RF模块失败,FlexiBTS检测到一个非正常操作,或射频模块内部功能故障 模块告警 可能发生的告警模块 FSMF或FBBA 高温告警 风扇故障告警 冷却风扇坏了 当BTS的参考时钟监控功能没有收到同步参考信号的时候产生该告警 基站发现无法在不重起基站的情况下使某个射频模块正常工作,需要重启基站 辅光纤光口故障告警 主光纤光口故障告警 BTS没有运行 不兼容的软件版本检测,SW不兼容或者版本不符 调试文件丢失或参数有缺失或不正确的值 启动软件更新后,配置数据迁移失败,SW文件回落,需要重新升级 S1接口断链 可能是有事RRU通道问题引起的驻波告警 通道告警,可能是光纤收发有问题 OCXO调整已经接近极限的值,需要重启,重启不恢复则需要衡欢对应模块 BTS同步启动期间失踪 BTS时间没有更新 单元配置数据分布失败(6253) SW文件下载出错 GPS接收器报警:控制接口不可用(4011) GPS接收器检测到一个或多个eepm段已经被发现在重置和损坏必须被设置为工厂默认设置。 NE断开之前上传完成,可忽略的告警 启动的时候PPS参考时钟丢失 S1接口断链 配置错误:单元初始化失败 固件软件不匹配,更新BTS已经失败或BTS SW损坏 互连光纤长度差异过大,超过60米,需要更换相同长度的光纤 TDS告警,检测TDS,LTE的软件版本,再检测TDS板卡 软件更新模块或组件失败,或SW文件损坏 系统输入功率模块检测到下行载波低 单位无法确认其产品代码或其物理设备地址(对象ID)。 二次光学系统模块和射频模块之间告警 系统模块故障;重启不恢复只能更换对应模块 1.可能是GPS天线安装尚未完成,正确;2.可能有GPS接收器故障;3.可能GPS接收器HW断层 RRU侧主光纤告警 所在基带或光线总线错误,需重置或者替换对应基带及光学线 SW文件验证失败,可尝试重新升级或者回退之前软件版本试一下 光口告警,可能是光纤或者光模块问题导致光口告警 RRU被锁 物理内存使用的内存已经超过90%(FCM / FCT)/ 98%(FSP) 光口异常告警
序号 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41
29 39 28 30
告警 VSWR minor alarm(1838) Failure in optical RP3 interface(3030) Configuration error: Not enough HW for LCR(3070) Connection lost Failure in replaceable baseband unit(3003) VSWR alarm(1837) Baseband bus failure(3020) RF module failure(3010) System module failure(3000) Temperature alarm(3040) Fan failure(3050) Fan failure during fan test(3050) BTS reference clock missing(3080) BTS reset required(4001) Failure In Optical Interface 1(3012) Failure In Optical Interface 0(3012) BTS is uncommissioned(4030) Incompatible SW version detected Commissioning error: Invalid Configuration file(3060) SW fallback(4082) Transport layer connection failure in S1 interface(6202) VSWR major alarm(1837) TX failure in MIMO(4003) BTS master clock tuning failure(1818) BTS synchronization is missing during startup(4160) BTS time not corrected Cell configuration data distribution failed(6253) Error in file server during SW download GPS Receiver alarm: Control Interface not available(4011) GPS Receiver alarm: EEPROM segments status(4126) NE disconnected before upload finished PPS reference clock missing in startup(4153) S1 interface setup failure(6308) Configuration error: Unit initialization failure(3070) Firmware SW mismatch(2056) Parallel RP3-01 link length mismatch(4072) TD-SCDMA minor alarm(4179) BTS internal SW management problem(3090) Cell power failure(4090) Configuration error: Unknown HW resource(3070) RF Loss of secondary optical interface(1930) System module failure F Failure In Optical Interface RRU optical/eletrical module absence 1(3012) RF BB bus connection transmission error(1906) Validation of signed file failed(4145) Failure in optical RP3 interface Unit blocked High memory consumption(6502) Failure In Optical Interface Abnormal CPRI interface to next hop 1(3012) 1935转速高 1932、33风扇坏