资料范本本资料为word版本,可以直接编辑和打印,感谢您的下载逆变器用户使用手册地点:__________________时间:__________________说明:本资料适用于约定双方经过谈判,协商而共同承认,共同遵守的责任与义务,仅供参考,文档可直接下载或修改,不需要的部分可直接删除,使用时请详细阅读内容GDLYEC-PV-3~270/500光伏并网逆变器用户使用手册版本2.0国电龙源电气有限公司目录TOC \o "1-3" \h \z \u HYPERLINK \l "_Toc327278738" 1关于本手册 PAGEREF _Toc327278738 \h 3HYPERLINK \l "_Toc327278739" 1.1 前言 PAGEREF_Toc327278739 \h 4HYPERLINK \l "_Toc327278740" 1.2 内容简介 PAGEREF_Toc327278740 \h 4HYPERLINK \l "_Toc327278741" 1.3 面向读者 PAGEREF_Toc327278741 \h 4HYPERLINK \l "_Toc327278742" 1.4 手册使用 PAGEREF_Toc327278742 \h 4HYPERLINK \l "_Toc327278743" 2 安全须知 PAGEREF_Toc327278743 \h 5HYPERLINK \l "_Toc327278744" 2.1 警示符号说明 PAGEREF_Toc327278744 \h 6HYPERLINK \l "_Toc327278745" 2.2 安全提示 PAGEREF_Toc327278745 \h 7HYPERLINK \l "_Toc327278746" 2.3 操作中的注意事项 PAGEREF _Toc327278746 \h 9HYPERLINK \l "_Toc327278747" 3 产品简介 PAGEREF_Toc327278747 \h 10HYPERLINK \l "_Toc327278748" 3.1 光伏并网系统 PAGEREF_Toc327278748 \h 11HYPERLINK \l "_Toc327278749" 3.2 产品特点 PAGEREF_Toc327278749 \h 11HYPERLINK \l "_Toc327278750" 3.3 电气原理 PAGEREF_Toc327278750 \h 12HYPERLINK \l "_Toc327278751" 3.4 产品外观 PAGEREF_Toc327278751 \h 14HYPERLINK \l "_Toc327278752" 4 产品功能与LCD操作指南PAGEREF _Toc327278752 \h 17HYPERLINK \l "_Toc327278753" 4.1 GDLYEC-PV-3~270/500主要功能 PAGEREF _Toc327278753 \h 18HYPERLINK \l "_Toc327278754" 4.1.1 并网发电 PAGEREF_Toc327278754 \h 18HYPERLINK \l "_Toc327278755" 4.1.2 MPPT功能 PAGEREF_Toc327278755 \h 18HYPERLINK \l "_Toc327278756" 4.1.3低电压穿越功能 PAGEREF _Toc327278756 \h 18HYPERLINK \l "_Toc327278757" 4.1.4 保护功能 PAGEREF_Toc327278757 \h 19HYPERLINK \l "_Toc327278758" 4.1.5 远程控制功能 PAGEREF _Toc327278758 \h 20HYPERLINK \l "_Toc327278759" 4.1.6自动开关机功能 PAGEREF _Toc327278759 \h 20HYPERLINK \l "_Toc327278760" 4.2 GDLYEC-PV-3~270/500运行模式 PAGEREF _Toc327278760 \h 20HYPERLINK \l "_Toc327278761" 4.3 GDLYEC-PV-3~270/500 LCD操作指南 PAGEREF _Toc327278761 \h 22HYPERLINK \l "_Toc327278762" 4.3.1 LCD主界面 PAGEREF_Toc327278762 \h 22HYPERLINK \l "_Toc327278763" 4.3.2 LCD控制指令发送 PAGEREF _Toc327278763 \h 24HYPERLINK \l "_Toc327278764" 5 产品安装 PAGEREF_Toc327278764 \h 30HYPERLINK \l "_Toc327278765" 5.1 注意事项 PAGEREF_Toc327278765 \h 31HYPERLINK \l "_Toc327278766" 5.2 机械尺寸 PAGEREF_Toc327278766 \h 31HYPERLINK \l "_Toc327278767" 5.3 放置与移动 PAGEREF_Toc327278767 \h 31HYPERLINK \l "_Toc327278768" 5.4 直流输入线缆连接 PAGEREF _Toc327278768 \h 32HYPERLINK \l "_Toc327278769" 5.4.1 直流输入电气参数规格PAGEREF _Toc327278769 \h 32HYPERLINK \l "_Toc327278770" 5.4.2 直流输入线缆要求 PAGEREF _Toc327278770 \h 33HYPERLINK \l "_Toc327278771" 5.4.3 线缆连接 PAGEREF_Toc327278771 \h 33HYPERLINK \l "_Toc327278772" 5.5 交流输出线缆连接 PAGEREF _Toc327278772 \h 36HYPERLINK \l "_Toc327278773" 5.5.1 交流输出电气规格 PAGEREF _Toc327278773 \h 36HYPERLINK \l "_Toc327278774" 5.5.2 交流输出线缆要求 PAGEREF _Toc327278774 \h 36HYPERLINK \l "_Toc327278775" 5.5.3 线缆连接 PAGEREF_Toc327278775 \h 36HYPERLINK \l "_Toc327278776" 5.6 系统地线连接 PAGEREF_Toc327278776 \h 38HYPERLINK \l "_Toc327278777" 5.6.1 地线线缆要求 PAGEREF _Toc327278777 \h 38HYPERLINK \l "_Toc327278778" 5.7 远程监控通信线连接 PAGEREF _Toc327278778 \h 38HYPERLINK \l "_Toc327278779" 6 产品运行指南 PAGEREF _Toc327278779 \h 40HYPERLINK \l "_Toc327278780" 6.1 启动 PAGEREF_Toc327278780 \h 41HYPERLINK \l "_Toc327278781" 6.2 关机 PAGEREF_Toc327278781 \h 42HYPERLINK \l "_Toc327278782" 7 电气特性 PAGEREF_Toc327278782 \h 431关于本手册关于本章本章介绍了本手册的主要内容、面向的读者、手册使用须知以及手册所使用的符号定义,帮助用户更好的阅读本手册内容。
EGS001驱动板手册
VREF 17
JP1
JP5
JP2
JP6
50/60Hz选择 软启动选择
温度反馈
+5V
电流反馈
电压反馈
EG8010.IR2110正弦波逆变器 驱动电路原理图(单极性调制方式)
9 NC 10 NC 11 VDD 12 HIN 13 SD 14 LIN 15 VSS 16 NC
接示波器
图 5‐2. EGS001 SPWM 输出测试滤波电路
旺旺 :qq453046836 电话:15825241006 QQ:453046836 答案666
4/4
NC GND GND +5V GND +12V GND TEST4 GND TEST3 GND TEST2 GND GND TEST1 GND GND
图 5‐1. EGS001 驱动板接线图
EGS001 小板测试说明
1) 测试时将 IFB、VS1、VS2、VFB、TFB 针脚接地 2) +12V 针脚接 DC 12V (电压 12 ~ 15V 之间均可) 3) +5V 针脚接 DC 5V 4) 用示波器接 TEST1~TEST4 观察波形,TEST1、TEST2 输出基频方波,TEST3、TEST4 输出 SPWM 波形,可
2. 电路原理图
EGS001 驱动板原理图
D1状态指示灯说明 正常:长亮
过流:闪烁2下,灭2秒,一直循环 过压:闪烁3下,灭2秒,一直循环 欠压:闪烁4下,灭2秒,一直循环 过温:闪烁5下,灭2秒,一直循环
+5V
R1 1K D1 LED
JP3 JP4
JP7 JP8
逆变器操作说明范文
逆变器操作说明范文逆变器是一种电力变换设备,可以将直流电转换为交流电,广泛应用于太阳能电池板、风力发电机等直流能源发电系统中。
逆变器的使用方法和操作说明如下:1.安装前准备:a.确保逆变器工作环境清洁、通风良好,不受高温、潮湿、灰尘等不利因素影响。
b.阅读逆变器的用户手册和安装指南,熟悉逆变器的特性、接线要求和安装方法。
c.确保逆变器的输入电压与电源电压匹配,且输入电流符合逆变器额定输入电流要求。
2.接线:a.根据逆变器的接线图和指示,正确接线逆变器的直流输入端和交流输出端。
b.使用标准电缆和连接器,确保接触良好,并进行充分的绝缘处理。
c.对于多台逆变器的并联使用,应根据指示正确接线,确保相应的连接稳固可靠。
3.开机操作:a.确保逆变器的输入电源已接通,并检查连接是否牢固可靠。
b.将直流输入电源连接到逆变器的直流输入端,并确保极性正确。
c.打开逆变器的开关,并观察指示灯是否亮起表示操作正常。
4.设置参数:a.使用逆变器的控制面板或遥控器设置逆变器的运行参数,如输出功率、频率、电压等。
b.根据实际需要,进行电压、频率、输出波形等参数的调节。
c.熟悉逆变器的各种保护功能和报警指示,根据需要设置相应的保护参数和报警阈值。
5.监控运行状态:a.使用逆变器配套的监控系统或软件,实时监控逆变器的运行状态和性能指标。
b.观察逆变器的指示灯状态,及时发现并处理任何异常情况。
c.定期检查逆变器的散热系统、风扇、接线等部分,确保工作正常并保持清洁。
6.关机和维护:a.在断电前,先关闭逆变器的开关,断开逆变器与电源的连接。
b.根据逆变器的维护手册,定期进行逆变器的清洁和检查工作,包括散热片、风扇、接线等部分。
总结:逆变器的操作相对简单,但需要按照指南和手册进行正确操作和设置。
在使用过程中,要随时监控逆变器的运行状态,及时处理异常情况,并进行适当的维护和保养,以保证逆变器的安全可靠运行。
此外,为了避免发生意外,操作逆变器时应保持注意力集中,防止和金属物、水、湿手等接触,避免触电和其他安全隐患。
工频逆变器说明书
工频纯正弦波逆变器说明书目录目录 (2)一.特点 (3)二.面板说明 (4)三.技术参数 (5)四.安装 (6)1.连接示意图 (6)2.使用导线平方数 (6)3.安装指南 (7)4.远程控制安装 (7)五.蓄电池类型选择 (8)六.工作原理 (9)1.充电阶段解释 (9)2.充电曲线图 (9)七.使用说明 (10)八.应用领域 (10)1.家庭娱乐 (10)2.家庭设备 (11)3.办公设备 (11)4.照明设备 (12)九.状态指示及故障对照表 (12)一.特点●安静,高效率运作●前面板LED指示灯和可调开关选择器●可选设置铅酸电池,胶体电池,或玻璃纤维隔板(AGM)电池●70A自动三阶段充电(大电流充电,吸收,和浮充)●快速开关(栅板到电池和电池栅板)的备用电源●较低的闲置电流(小于1瓦)能和发动机一致,在没有负载情况下节约能源.●在极端环境条件下具有持久的寿命●高负载能力可以承担比较大的负载,在过载情况下能稳定处理电路板形涂层可以保护他们免遭腐蚀及提高使用寿命和可靠性●持久的粉末涂层,耐腐蚀钢底盘,具有防水功能●保护功能:a)过电压和低电压保护b)高温保护c)自动过载保护d)短路保护二. 面板说明正面面板交流输出端面板 市电输入零线 市电输入火线 机器输出地线市电输入地线 机器输出零线 机器输出火线远程指示灯三. 技术参数输入波形 正弦波(实用工具或发电机)标称输入电压 120V 230V低压跳闸 90V ±4% 184V/154V ±4% 低压重启 100V ±4% 194V/164V ±4% 高压跳闸 140V ±4% 253V ±4% 高压重启 135V ±4% 243V ±4% 交流最大输入电压 150V 270V额定输入频率 50Hz/60Hz(自动检测)低频跳闸 47Hz-50Hz, 57Hz-60Hz高频跳闸 55Hz-50Hz, 65Hz-60Hz输出波形 与输入波形相同(旁路模式)过载保护 断路器短路保护 断路器转换开关额定值 30安培/40安培在线转换式转换效率 95%以上线传输时间 10ms (标准)旁路无电池连接 是旁路最大电流 30安/40安旁路过载电流 35安/45安(报警)逆变器规格/输出输出波形 纯正弦波持续输出功率 1000W 2000W 3000W 4000W 5000W 6000W 持续输出功率 1000V A 2000V A 3000V A 4000V A 5000V A 6000V A 功率因数 0.9-1.0输出电压调节 ±10% rms输出频率 50Hz ±0.3Hz 60Hz ±0.3Hz额定效率 大于88%峰值额定值 3000 6000 9000 12000 15000 18000 短路保护 是 , 故障后十秒 接蓄电池端面板 直流输入负极 直流输入正极逆变器规格/输入额定输入电压12V 24V 48V最小启动电压10V 20V 40V电瓶低电压报警10.5V 21V 42V电瓶低电压脱扣10V 20V 40V高压报警16V 32V 64V节电器启用时低于25瓦节电器远程均为开关调节充电器模式规格输入电压范围95-127VAC 194-243V AC/ 164-243V AC(W)输出电压根据电池类型充电电流35A/70A启动时电瓶初始电压0-15.7V,12V (*2,24V; *4, 48V)过充保护关断15.7V, 12V (*2,24V; *4, 48V)电瓶类型决定充电器(恒定电流四阶段)数控渐进充电四步走远程控制/RS232/USB 是,可选尺寸(mm)1000W/2000W/3000W: 442*218*179mm4000W/5000W/6000W: 598*218*179 mm 重量:1000W 2000W 3000W 4000W 5000W 6000W18kg 20kg 22kg 35kg 38kg 40kg 四.安装1.连接示意图2.使用导线平方数充电或逆变电流导线长0-1.5 米导线长1.5-4.0米3.安装指南a)将本品与蓄电池组距离尽量拉近b)保持阴凉,干燥以及良好通风c)本品放置方向无关d)无论从原厂购买1.5米长的导线,或者使用你自己的线,都要按照导线平方数表所指明的粗细以确保对直流电流足够粗。
EG系列发电机使用维护手册(中文)
REV 1.0/0607ENGGAThree-phase Synchronous Generators 三相同步发电机Operation & Maintenance Manual安装和维护手册安全指南EG发电机采用最新的发电机设计、生产工艺、质量控制理念,拥有出众性能、可靠质量、优质发电机。
敬请各位用户在使用前务必仔细阅读和理解本手册中有关发电机安装、使用和维护的内容。
安装、调试、检修必须由具备相关工作资格的专业人员进行,操作人员应能掌握正确的使用方法、安全操作,否则有可能引起严重的人员伤亡或设备损坏事故。
①警示标识本手册中使用和随发电机提供的警示和警告标识的含义如下,发电机组配套商应确保警示标签位置放置正确并清晰,标签含义如下:A.普通警告标识,可能会导致人员伤亡、设备损坏的危险B.电气危险标识,可能电气原因会导致人员伤亡的直接危险C.通用危险标识,可能会导致人员伤亡的直接危险② 发电机警告标签的位置目录1 概述1.1 标准1.2 发电机型号代表意义1.3 铭牌1.4 接收检查及储存2 发电机的使用环境2.1 使用环境2.2 发电机的容量修正3 发电机结构3.1 发电机的工作原理3.2 定子3.3 转子3.4 励磁系统4 安装4.1 安装环境4.2 安装4.3 转向4.4 接线4.5 接地、保护5 运行5.1 运行前的检查5.2 运行前的试验调整5.3 开机与停机5.4 并联运行6 维护和检修6.1 一般维护6.2 检修项目6.3 发电机的拆装6.4故障现象及排除6.5 A VR故障检修7 结构图结构图零件表本安装使用维护手册阐述了英格EG系列交流发电机的结构特点、性能原理、安装使用和维护检修。
1 概述1.1 标准发电机符合下列国际和相关国家标准:I.E.C 60034-1 国际电工委员会标准BC5000 英国标准NEMA MG21 美国标准C.S.A C22-2 加拿大标准VDE 0530 德国标准GB755 中国标准1.2 发电机型号意义:EG发电机的型号按照以下方式命名例如:EG280S—120NEG---表示EG系列发电机280---表示发电机的机座号(160、225、280、315、355、400、500)S---表示机座的长短(M、L)120---表示发电机的容量带,KWN---表示发电机的改进、用途,N---新改进的NEW系列;H---船用系列;B---变形产品1.3 铭牌发电机铭牌位于驱动端右侧机体上。
LSCg001e_neo_REV_15_Serie_ZH说明书
使用说明目录1.概述 (4)1.1.版权 (4)1.2.安全信息符号 (4)1.3.免责声明 (4)1.4.制造商、适用标准和CE认证 (4)1.5.向制造商和监管机构报告 (7)1.6.用户安全操作说明和用户资质要求 (7)2.产品使用寿命和保修条件 (7)3.交付范围 (8)4.预期用途 (9)4.1.器械的用途 (9)5.设置和调试。
(9)6.电气连接 (10)7.产品描述和控制 (11)7.1.连接 (11)7.1.1.电源连接 (11)7.1.2.开/关和启动开关 (11)7.1.3.电源插座 (12)7.2.头枕和操纵杆盒上的控制装置 (13)7.2.1.取下头枕泡沫垫 (14)7.3.EAZY GO轮(可选件) (14)7.4.更换保险丝 (15)7.5.P ATIENT S UPPORT S YSTEM LSC NEO 上的安全信息和信息标签 (16)8.PATIENT SUPPORT SYSTEM LSCNEO 操作 (21)8.1.设置和(重新)定位P ATIENT S UPPORT S YSTEM LSC NEO (21)8.2.开关开启和参考程序。
(21)8.3.旋转顶部 (22)8.3.1.Patient Support System LSCneo使用激光装置操作。
(23)8.4.调整头枕 (23)8.4.1.电动高度调整 (23)8.4.2.机械头枕腹侧/背侧倾斜 (23)8.4.3.紧急程序、电源故障或其他技术故障。
(24)8.5.操纵杆 (24)8.5.1.操纵杆和电动头枕控制装置可用性 (24)8.5.2.操作模拟操纵杆 (24)8.5.3.控制 Z、Y 和 X 轴 (25)8.5.4.自动运动 (25)8.5.5.反向功能 INV (25)8.6.紧急停止按钮和重启程序。
(26)9.清洁洁洁洁洁护 (27)10.维护 (27)11.产品安全检查 (27)12.器械废弃处置 (27)13.技术数据 (28)14.故障排除 (30)15.电磁兼容性(EMC) (31)15.1.电源电缆简介 (36)1. 概述为了安全操作和控制 Patient Support System LSCneo ,请仔细阅读本用户手册。
OLYS 正弦波逆变器 充电逆变一体机 使用说明书
1. 本产品可适用冰箱,洗衣机,手电钻等感性负载。
2. 超低的待机功耗,待机功率仅为0.3W3. 输入电压可适用12V 或者24V (只能任选一种).4. 多种安全保护及声音报警.5. 具有电池优化功能,让你的蓄电池更耐用5. 内置太阳能充电控制器(充电逆变一体机)1. 不正确的安装会导致设备的损坏,造成功能不良或者对用户潜在的危害2. 逆变器工作是会产生高压,如果接触有电部分会导致致命危险,因此,针对逆变器的任何操作,必须小心。
3. 不允许用户操作逆变器内部的任何部分。
4. 不要将任何产生电流或电压的发生装置(比如公共电网,发电机等)接到逆变器的输出端,会将产品烧毁。
5. 本产品充电适用于铅酸蓄电池或者胶体电池。
6. 远离未授权接触产品的人,特别是儿童。
正弦波逆变器充电逆变一体机使用说明书感谢你使用奥林斯产品,在使用产品之前,请仔细阅读本产品说明书1. 安装位置: 请安装在干燥的地方(最大湿度95%),不能直接 安放在蓄电池上面。
周围通风必须通畅,产品各个方向最少 保留10CM 的空间,便于散热。
不要将易燃易爆的物品放在产品 周围。
2. 使用M 5螺丝把逆变器固定在不易燃烧的平面上,螺丝不随机配送。
1. 负载连接逆变器的接线必须非常小心,首先要接负载,当有交流电输出的时候 避免任何接触。
一旦接上负载,在逆变器连接蓄电池前,请确保其 处于关闭状态。
2 蓄电池连接.●在蓄电池端上必须安装保险丝● 蓄电池接线时仔细观察端子的颜色,区分正负极。
正负极接 反,会导致产品烧坏。
● 蓄电池连接请参考以下颜色区分: 黑色接线端子: 负极(-) 红色接线端子: 正极(+)注意: 当接通蓄电池时会有火花产生,属于正常现象。
(给内部 的滤波电容充电)●请尽可能的不要延长蓄电池电缆,会引起压降损耗,造成逆变器 误操作, 建议线长不要超过2米 线经推荐: 500W /600W :6mm 300W /400W :4mm注意事项:连接方法22以下情况逆变器具有声音报警过热: 当温度差3℃达到高温保护值时,蜂鸣器响,如果此时减小负载电流,温度恢复到正常水平,逆变器输出电压不会被中断蓄电池低电压: 蓄电池低电压切断逆变器输出前蜂鸣1分钟,如果蓄电池电压上升,可以避免逆变器低压保护按开关启动逆变器: 长鸣2秒钟,马上有电压输出注: 声音报警功能可以设置关闭3. 输出电压闪变报警当关闭了声音报警或者无法听到报警声时,此方式可以提醒用户因为过热或者蓄电池低电压造成逆变器即将停机, 如果开启这个功能,输出电压将会闪变,导致灯的亮度闪变,用来提示用户蓄电池即将没电,这时,用户可以减小负载功率来保证优先负载的供电(例如照明)4. 待机功能本逆变器具有独特的待机功能,当检测到没有负载时,通过间歇地关闭逆变器来节省能量,在这个模式下LED1闪烁,表示间歇性的输出电压每一秒钟输出一个正弦波. 逆变器进入待机模式时候,待机功耗仅为0.4W出厂默认负载探测值:5W. 当负载功率小于5W时候. 没有电压输出. 当负载>5W时,立刻有电压输出.注: 出厂默认待机功率可根据用户需求来调整,订货时候请向工厂注明需求功能开启和关闭用户可以对逆变器的以下功能进行自由的开启或关闭1. 逆变器即将停机前声音报警2. 蓄电池优化程序3. 逆变器即将停机前输出电压闪变设置方法按住ON/OFF键持续特定的时间(对应每个功能,参考下表),蜂鸣器指示相应的功能是处于开启或关闭状态一声短蜂鸣声(嘀) = 功能开启二声短蜂鸣声(嘀嘀) = 功能关闭听到蜂鸣声后, 两秒内释放ON/OFF键, 功能的状态将会改变(翻转). 如果不希望改变设置而了解功能状态,用户可一直按住ON/OFF键. 当超过20秒,将会听到持续的蜂鸣声,至少顺序的结束,松开按键声音会停止, 将不会影响或者改变功能的设置.1. 逆变器具有电子保护电路。
正弦波逆变电源用户手册(完整)Word版
用户手册正弦波逆变电源(220VDC 0.5KVA~3 KVA)合肥尚源电气科技有限公司目录第一章序言 (1)1.1注意事项 (1)1.2产品执行标准 (2)1.3开箱、存放和搬运 (2)1.3.1开箱 (2)1.3.2 存放 (3)1.3.3搬运 (3)第二章产品简介 (4)2.1 主要技术指标 (4)2.2 工作环境 (5)2.3原理框图 (5)2.4 运行方式 (5)2.4.1 交直流互备运行模式 (5)2.4.2 在线运行模式 (6)2.4.3 主备运行模式 (6)第三章逆变电源的保护功能 (7)3.1 保护类别与动作状态 (8)3.2 过、欠压保护与返回参数 (8)第四章安装运行 (9)4.1 安装准备 (9)4.1.1 负载配置指导 (9)4.1.2 主回路推荐配线 (9)4.2 安装 (10)4.2.1 卧式逆变电源外形及安装尺寸图 (10)4.2.2后面板接线端子定义 (10)4.2.3后面板通讯及报警端子定义 (11)4.2.4线图 (12)4.3 运行 (12)4.3.1 面板及菜单说明 (12)4.3.2 开机 (13)4.3.3 各键功能 (13)4.3.4 菜单介绍 (13)4.3.5 监控通讯 (15)4.3.6 注意事项 (16)第五章显示异常信息及处理方法 (18)5.1 常见故障现象和处理方法 (18)5.2 过载或短路保护的恢复 (18)5.3 更换风扇 (19)第六章维护保养与维修服务 (20)6.1 维护保养 (20)第一章序言SYN系列逆变电源是采用DSP控制的新一代产品。
在原有产品的基础上,新型逆变电源增加了液晶显示、标准RS-232/485通讯接口、在线灵活设定旁路优先或逆变优先工作模式、上位机遥控、遥信和遥测等功能。
采用三菱公司最新IPM模块和进口高效率变压器,整机体积、重量进一步减小。
在有直流屏的发电厂、电力系统和通信机房等场所,采用逆变电源与采用常规不间断电源(UPS)相比,前者有以下优点:▲避免蓄电池的重复投资,减少系统的维护,降低系统运行成本;▲由于直流屏通常采用阀控式密封电池,电池的浮充寿命可长达15年,因此采用直流动力加逆变电源,其供电可靠性和寿命大大提高;▲由于直流电池屏容量均较大,因此采用逆变电源供电时,在市电断电后可提供较长的交流供电时间。
TPower系列纯正弦波逆变器用户手册说明书
Pure Sine Wave InverterUser ManualTP10K/TP10KBContentsImportant Safety Instructions (1)1. Product Overview (5)1.1 Information & Features (5)1.2 Structure (6)1.3 Name definition (9)1.4 Connection schematic diagram (9)1.5 Electrical schematic diagram (10)2. Installation (11)2.1 Warning (11)2.2 Wire & breaker selection (11)2.3 Instructions (12)2.4 Output voltage/frequency grade switch (17)3. Interface (18)3.1 Indicator (18)3.2 Buzzer (19)3.3 Buttons (19)3.3 LCD Display (19)3.4 Icon (20)3.5 Operation (20)4. Protection (22)5. Troubleshooting (25)6. Maintenance (27)7. Specifications (28)AnnexⅠ Disclaimer (32)AnnexⅡ Mechanical Dimension Diagram (33)Important Safety InstructionsPlease reserve this manual for future review.This manual contains all the instructions about safety, installation, and operation for TPower series pure sine wave inverter (hereinafter referred to as the inverter).Explanation of symbolsTo enable the user to use the product efficiently, as well as to ensure personal and property safety, this manual provides related information and emphasize the following symbols.Please read the related words carefully when you encounter the following symbols in the manual.TIP:Indicates any practical advice for reference.IMPORTANT:Indicates a critical tip during the operation, if ignored, may cause the device to run in error.CAUTION:Indicates potential hazards, if not avoided, may cause the device damaged.WARNING:Indicates the danger of electric shock, if not avoided, would cause casualties.WARNING HOT SURFACE:Indicates the risk of high temperature, if not avoided, would cause scalds.Read the user manual carefully before any operation.Symbols of inverterWARNING: The entire system should be installed by professional and technical personnel.2. Requirements for professional and technical personnel:•Professionally trained;•Familiar with related safety specification for the electrical system;•Read this manual carefully, and master related safety cautions.3. Professional and technical personnel is allowed to do:•Install the inverter to the specified location;•Conduct trial operations for the inverter;•Operate and maintain the inverter.4. Safety cautions before installation:IMPORTANT: When receiving the inverter, please firstly check if there is any damage occurred in transportation, if find any problem, please contact the transportation company or our company in time.CAUTION: When place or move the inverter, must follow the instructions in the manual.CAUTION: When install the inverter, must evaluate whether the operation area exists any arc danger.WARNING: Do not place the inverter in places where children can touch.WARNING: The inverter is off-grid type, and it is strictly prohibited to be connected to the grid; otherwise the inverter would be damaged.WARNING: The inverter is only allowed for stand-alone operation, and it is prohibited to connect multiple units’ output in p arallel or in series; otherwise the inverter would be damaged.5. Safety cautions for mechanical installation:WARNING: Before installation, must make sure the inverter has no electrical connection.WARNING: Ensure the heat dissipation space for the inverter installation, and do not install the inverter in humid, greasy, flammable, explosive, dust accumulative or other severe environments.6. Safety cautions for electrical connection:CAUTION: Check if all the wiring connections are tight, to avoid the danger of heat accumulation due to a loose connection.WARNING: Both utility input and AC output are of high voltage, do not touch the wiring connection to avoid electric shock.7. Safety cautions for inverter operation:WARNING HOT SURFACE: When the inverter is working, its heat sink and casing will generate a lot of heat, the temperature would be very high, please do not touch it.CAUTION: When the inverter is working, please do not open the inverter cabinet to operate.8. The dangerous operations which would cause electric arc, fire or explosion: •Hot plug the high voltage fuse on the inverter DC side.•Touch the wire end which hasn’t been insulation treated and maybe electriferous.•Touch the wiring copper row, terminals or internal devices which may be electriferous.•Power cable connection is loose.•Screw or other spare parts inadvertently falls into the inverter.•Incorrect operation by untrained non-professional or technical personnel.WARNING: Once an accident occurs, must be handled by professional and technical personnel. Any incorrect operation would cause a more severe accident.9. Safety cautions for stopping the inverter:•Firstly turn off the breakers on the utility input side and AC output side, then turn off the DC switch;•After the inverter stop working for five minutes, the internal conductive devices could be touched;•The inverter can be restarted after removing the faults which may affect its safety performance;•No maintenance parts in the inverter, if any maintenance service is required, please contact our after-sales service personnel.10. Safety cautions for inverter maintenance:•Testing equipment is recommended to check the inverter, to make sure there is no voltage or current;•When conducting electrical connection and maintenance work, must post temporary warning sign or put up barriers, to prevent unrelated personnel from entering the electrical connection or maintenance area;•Improper maintenance operation to the inverter may cause personal injury or equipment damage;•To prevent electrostatic damage, recommend to ware antistatic wrist strap or avoid unnecessary contact with the circuit board.CAUTION: The safety mark, warning label and nameplate on the inverter should be clearly visible, not removed or covered.1.Product Overview1.1Information & FeaturesTPower series is designed aspure sine wave power frequency inverter, whichconverts 110/220VDC to220/230VAC.Thisdevice consists of a DC-AC inverting module and AC-AC bypass module in parallel, also featuredwithhigh reliability, high efficiency, concise appearance, full protection, easy installation and operationfunctions.DC-AC inverting module is anintelligent and full digital designed component with advanced SPWM technology. The module is designed with the pure sine wave output toconvert 110/220VDC to220/230VAC for multiple types of AC loads, such as home appliances, electric tools, industrial devices, audio equipment and solar photovoltaic system.AC-AC bypass module used advanced control algorithm to ensure the stability of output voltage and achieve the fast switching feature. Also the high reliability and high-performance semiconductor inside the module reduce the size and prolong the service life.The 4.2 inches segment type of LCD displays the system operation data and statesin real time.The case in sheet-metal design is featured with high intensity and shielding electromagnetic interference. Also, the universal rotary caster is optional for the system, which contains lifting support feet to fix or move the inverter at anytime and improve product mobility and flexibility.Features:•Advanced SPWM technology and pure sine wave output•Fully digitalized voltage and current double closed-loop control•Low output harmonic distortion(THD≤3%)•Mode selection of bypass priority and inverter priority•Output voltage 220/230VAC and frequency 50/60Hz selectable•Real-time power queryand output power statistics function•Automatic protection featuresof the short circuit, overheating and overload.• 4.2 inches LCD display the system operation data and state dynamically with friendly AI interface•Multiple LED indicators show the operating status of the system in real-time •Designed with soft boot control to avoid the battery be damaged by high current impact when turning on the system•AC OUT button controls the AC output individually•Smart fan control reduces energy consumption and noise•Use popular semiconductor modules with high reliability and low power consumption•Designed with remote switch & RS485 communication interface to achieve the features of remote monitoring and hardware Stop&Start, also the Wi-Fi and Bluetooth communication modules are selectable•Universal rotary caster is optional for free movement and fixation.•Modular design, easy maintenance and repair1.2 Structure(1) FOOT MASTER caster(Optional accessory)Rotate clockwise to raise the supporting feet, then tomove the inverter.Rotate counterclockwise to lower the supporting feet,then to fix the inverter.⑵Terminals and breakers★Interface connection method :(3)DC fan and AC fanDC fan 2 pieces:When the radiator temperature rises to 45℃ above, the DC fans will start; when the radiator temperature declines to 35℃ below, the DC fans will stop .IMPORTANT: DC fans have the self-checking function when the inverter is powered on, the DC fans would run for three seconds automatically.AC fan 3 pieces:Inverter priority:When the internal temperature rises to 35℃ above, and with inverter output, the AC fans will start.When internal temperature declines to 30℃ below, or with no inverter output, the AC fans will stop.1.3Name definition1.4Connection schematic diagramWARNING: The AC equipment must be determined according to the output power of the inverter. Do not connect the load in excess of the inverter’s maximum input power, otherwise, the inverter may be damaged.2. Installation2.1 Warning•Please read the manual carefully to get familiar with the installation steps before installation.•Be very careful when installing the batteries, especially flooded lead-acid battery.Please wear eye protection, and have fresh water available to rinse if any contact with battery acid.•Keep the battery away from any metal objects, which may cause a short circuit of the battery.•Loose connections and corroded wires may result in high heat that can melt wire insulation, burn surrounding materials, or even cause a fire. Ensure tight connections and use cable clamps to secure cables and prevent them from swaying in motion.•Select the system connection cables according to the current density no higher than 5A/mm2.(In accordance with the National Electrical Code Article 690, NFPA70).•For outdoor installation, keep out of the direct sunshine and rain infiltration.•High voltage still exists inside the inverter after turning off the switch, do not open or touch the internal devices, wait five minutes before conducting related operations.•Please do not install the inverter in humid, greasy, flammable, explosive, dust accumulative or other severe environments.•Prohibit reverse connection at the battery input end; otherwise it will easily damage the equipment or cause unpredictable danger.•Both utility input and AC output are of high voltage;please do not touch the wiring connection.• When the fan is working, please do not touch it to avoid injury.2.2 Wire& breaker selectionWiring and installation mode should comply with national and local electrical code requirements.••TP30KBIMPORTANT: The wire size is for reference only, use thicker wires to lower the voltage drop and improve the system performance when the distance between utility and inverter or between inverter and batter is far.IMPORTANT: The above wire size and circuit breaker size are for recommendation only, please choose suitable wire and circuit breaker according to the practical situation.2.3InstructionsInstallation steps:Step1:Professional personnel read this manual carefully.Step2:Determine the installation location and heat dissipation space.Move the equipment: as the equipment is relatively large, it is recommended to use forklift or crane; if the ground is flat, it can be moved by wheels.Place to the location: As the equipment is heavy, it is recommended to be placed on flat ground, with 300mm space reserved all around, to ensure heat dissipation.Fix the equipment: If choose the optional caster, rotate counterclockwise to fix and rotate clockwise to move.WARNING: Risk of explosion!Never install the inverter with flooded batteries in a sealed enclosure! Do not install the device in a confined area where battery gas can accumulate.Step3:Take down the junction box cover plate with special tools.Step4:WiringWiring order:❶Ground——❷Battery——❸Utility——❹AC loadsWARNING: Never connect the utility to the inverter output; otherwise the inverter may be damaged.•GroundingThe voltage of the whole system exceeds the safety voltage level. Thus reliable grounding is needed. The grounding wire shall be the thicker wire(no less than 35mm2), and shall be as short as possible. The grounding point shall be as close as possible to the inverter.CAUTION: When wiring, follow the order ❶❷❸❹ to connect the cables to the equipment, then follow the order ❶❷❸❹ to connect ground, battery, utility and load.WARNING: Make sure all the wiring connections are reliable, otherwise massive heat would accumulate at the connection points to damage the terminals, or even cause a fire.WARNING: Danger, high voltage! Utility input, AC output and DC input will produce high voltage, do not close the breakers during wiring, and make sure the correct polarity of each component.Step5:Connect accessories•Mobile APP(For Android only)Download software:—EPEVER(TP)Communication cable: M12-6-male pin + crystal head-1000mm-v1.0Modules: eBox-WIFI-01 and eBox-BLE-01•PC SoftwareDownload software:—Inverter Monitor(TP)Communication cable: 1.M12-6-male pin + crystal head-1000mm-v1.02.RJ45 Coupler3. CC-USB-RS485-0.3mm2-3m-V1.1Step6:Double check the reliability of wiring connections.Step7:Put on the cover plate.Indicator:Inverter indicator on solidLCD:Step8:Close the bypass circuit breakerThe indicator:utility indicator on solidLCD:Step9:Close the load circuit breakerLCD:Step10:Inverter outputMethod 1: Press the “AC output” button for 3 seconds, the inverter would start the output.Method 2: Connect the remote switch, short-circuit the cable 1(red) and cable 2(white) of the remote switch and RS485 communication interface, the inverter would start the output.Indicator:Inverter indicator slowly flashing and load indicator on solid.LCD:Step11:Turn on the loadLED indicators: Inverter and load indicators are slowly flashing.CAUTION: In case the power is supplied to the different AC loads, it is suggested to turn on the loads with larger surge current first, till the load working well, then turn on the loads with smaller surge current. Especially for inductive loads, should be turned on one by one. Do not turn on the loads at the same time, so as not to cause excessive impact to the inverter, to shorten its life span.CAUTION: In case the inverter is not in regular operation, or LCD or indicator displays abnormal, refer to Section 5 to clear the fault or contact the after-sale service personnel of our company.Step12:Power off the equipmentOpen the AC load circuit breaker—long press “AC output” button to turn off the inverter output—open the bypass circuit breaker—open the battery circuit breaker.WARNING: As electricity exists in the capacitance, the LCD screen would be off after 30 seconds; wait 5 minutes before opening the equipment to repair.WARNING: After the inverter is disconnected from utility and battery bank, need to wait 5 minutes before touching the internal conductive devices.WARNING: As the inverter has soft stat design and only takes effect when the first time it starts, do not frequently switch the input circuit breaker when the inverter is incompletely powered off, otherwise the input battery would undergo high current impact. That is, the input circuit breaker can be closed again after the LCD screen is off.2.4Output voltage/frequency grade switchWhen the dial switch 1 is placed to the ON side, the outputfrequency is 60Hz, otherwise it is 50Hz,When the dial switch 2 is placed to the ON side, the outputvoltage is 230VAC, otherwise it is 220VAC.Operating steps:Open the cover plate on the inverter right side, find the dial switches on the control board which is located on the top left corner, see above picture. Set the outputvoltage/frequency according to demand, then restart the inverter to take effect.IMPORTANT: The factory default output voltage is 220VAC, the output frequency is 50Hz.IMPORTANT: The accessories can refer to the Packing list.3. Interface3.1Indicator3.2 Buzzer3.3 Buttons3.3LCDDisplay3.4 IconIcon Icon3.5 Operation1) Turn on the load:Operation:P ress the “AC output” button for 3seconds, load indicator changes from off to solid on.•Switch from inverter mode to bypass modeOperation:P ress “inverter/bypass” button for 3seconds, bypass indicator changes from off to solid on, inverter indicator changes from on solid to off.3)Clear electricity modeOperation:P ress“inverter/bypass” and “browse” button for 3seconds together to clear the accumulated consumed electricity.•Clear faultOperation:Under failure state, short press any button, the buzzer would stop sounding, but the failure code would still be displayed.IMPORTANT: In case of a non-recoverable failure state, if confirmed the fault is cleared, long press “browser” and “AC output” buttons together to clear the fault, the inverter would recover the output.Press the “Browse + AC output” buttons to clear the faults, the inverter recover output.6.MaintenanceThe following inspections and maintenance tasks are recommended at least two times per year for the best performance.•Make sure no block on air-flow around the inverter. Clear up any dirt and fragments on the radiator.•Check all the naked wires to make sure insulation is not damaged for serious solarization. Frictional wear, dryness, insects or rats, etc. Repair or replacesome wires if necessary.•Check and confirm that indicator and display is consistent with required. Pay attention to any troubleshooting or error indication .Take corrective action ifnecessary.•Confirm that all the terminals have no corrosion, insulation damaged, high temperature or burnt/discolored sign, tighten terminal screws to the suggested torque.•Check for dirt, nesting insects and corrosion. If so, clear up in time.•Check and confirm that lightning arrester is in good condition. Replace a new one in time to avoid damaging the inverter/charger and even other equipment.WARNING:Risk of electric shock!Risk of electric shock! Before the above operations, make sure that all the power is turned off, and the electricity in the capacitances is completely discharged, then follow the corresponding inspections and operations.★Instruction for inverter derating1. Temperature derating:When the temperature is over 45℃(113℉), the output power shouldbe reduced by 1KW (Kilowatts) for each 1℃ (Celsius) increase•TP10K,TP10KB•TP20K,TP20KB•TP30K,TP30KB302.Altitude derating:When the altitude is over 1500m, the output power should be reduced by 1KW (Kilowatts) for each 500m (Meter) increase•TP10K,TP10KB•TP20K,TP20KB•TP30K,TP30KB31Mechanical ParametersAnnexⅠDisclaimerThis warranty does not apply under the following conditions:•Damage from improper use or use in an unsuitable environment.•Load or utility current, voltage or power exceeds the rated value of the inverter. •Damage caused by the ambient temperature exceeds the limit working environment temperature.•The accident caused by disobeying the marks or manuals of the inverter, such as electric arc, fire and explosion.•User disassembly or attempted to repair the inverter without permission. •Damage caused by force majeure.•Damage caused during transportation orloading/unloading.32AnnexⅡ Mechanical Dimension Diagram 1.TP10K,TP10KB332.TP20K/TP20KB343.TP30K/TP30KBAny changes without prior notice! Version number: V1.135HUIZHOU EPEVER TECHNOLOGY CO., LTD. Beijing Tel: +86-10-82894896/82894112 Huizhou Tel: +86-752-3889706E-mail:******************Website: 。
工频正弦波逆变器用户手册
工频正弦波逆变器用户手册Copyright2009-2012产品名称:……………………………………………………………经销点或代理商(盖章有效) 型号………………………………………………………检验员…………………………………………联系电话………………………………………………………联系人…………………………………………编号………………………………………………………地址………………………………………………………………电话……………………………………………购机日期………………………………………………………………传真……………………………………………第12页前言尊敬的用户您好,感谢您购买及使用本公司逆变器。
在您使用本产品前,我们恳请您抽出宝贵的时间阅读本说明书,我们将告诉您逆变器使用的环节,包括安装和使用。
请严格遵守手册中和机器上的所有警告及操作说明,并善保管好本手册!第1页目录目录 (2)一、安全注意事项 (3)二、功能特点 (4)三、面板说明 (5)四、后板说明 (6)五、技术规格表 (7)六、安装及使用.........................................8-10七、保修与服务........................................11-12第2页七、保修与服务凡属在正常使用情况下由于产品本身质量问题引起的故障在保修期内,本公司将负责给予免费维修。
7-1保修须知:1、在正常使用条件下,因产品本身原因发生故障的均属于保修范围,保修一年,从购机之日起计算;2、在保修期间,客户可将产品送到各维修站,免费维修,已过保修期的产品酌情收取成本费3、用户擅自拆启机箱检修将自动失去免费保修服务,严重者维修站有权拒绝维修,后果自负7-2下列情况不属于保修范围1、未按说明书的要求操作所引起的故障2、因不可抗拒的自然因素引起的损坏3、因用户使用不当引起的损坏4、非本公司维修人员维修过的产品5、超过保修期的产品6、零配件使用寿命到期(电池)第11页为防止空气开关/熔断器保险过大,负载过载时保险不起作用。
EGS01中文说明书
4.1. 执行器特性参数......................................................................................23 4.2. 执行器接线图及注意事项 .......................................................................23 4.3. 安装及注意事项......................................................................................24 4.4. 执行器的标定..........................................................................................24 4.5. 执行器一般检查程序...............................................................................24 4.6. 故障排除.................................................................................................25
注意
电子产品内有对静电敏感的器件,为防止设备损坏,接触设备时请注意以下事项:
• 请勿打开设备外壳, • 特殊情况必须开盖检查时,请事先消除人体静电(关掉控制器电源,触摸接地
逆变器安装使用手册说明书
目录1本手册相关说明 (1)1.1适用范围 (1)1.2适用人员 (1)1.3本手册中使用的符号 (2)2安全 (3)2.1目标用途 (3)2.2安全标准 (3)2.3重要安全信息 (4)2.4标签上的符号 (6)2.5基本保护措施 (7)3拆箱和检查 (8)3.1交付清单 (8)3.2检查 (8)4逆变器的安装 (9)4.1安装环境条件 (9)4.2选择安装位置 (11)4.3安装逆变器 (12)5电气接线 (14)5.1安全说明 (14)5.2无集成直流开关的系统设计 (15)5.3连接区域概述 (15)5.4交流电连接 (16)5.4.1交流电连接条件 (16)5.4.2电网连接 (17)安装使用手册V00 I5.4.3辅助保护性接地连线 (19)5.4.4漏电流保护 (20)5.4.5过压类别 (20)5.4.6电网断路器 (21)5.5直流电连接 (22)5.5.1直流连接条件 (22)5.5.2组装直流电连接器 (23)5.5.3拆卸直流电连接器 (25)5.5.4连接光伏阵列 (26)6通信 (27)6.1通过RS485监测系统 (27)6.2通过以太网实现系统监视 (31)6.3通过WIFI进行系统监视 (32)6.4 使用第三方通信设备 (32)7 试运行 (33)7.1电气检查 (33)7.2机械检查 (34)7.3启动 (34)8操作 (35)8.1控制面板概述 (35)8.1.1显示屏 (36)8.1.2控制按钮 (37)8.1.3 LED指示灯 (37)8.2显示信息 (38)8.3 语言与并网安规设置 (40)8.3.1语言设置 (40)8.3.2并网安规设置 (40)9从电源上切断逆变器 (42)10技术数据 (43)10.1直流输入数据 (43)10.2 交流输出数据 (44)10.3一般参数 (45)10.4安全规范 (46)10.5效率 (47)10.5.1 Zeverlution 1000S 效率曲线 (47)10.5.2 Zeverlution 1500S效率曲线 (48)10.5.3 Zeverlution 2000S效率曲线 (49)10.5.4 Zeverlution 3000S效率曲线 (50)10.6降载曲线 (51)10.7工具和扭矩 (53)11故障排除 (54)12维护 (56)12.1清理直流开关触点 (56)12.2清理散热器 (56)13循环利用和废弃处置 (57)14保修 (57)15联系我们 (57)1本手册相关说明一般注意事项Zeverlution是一款无变压器型光伏逆变器,并自带一路MPP跟踪器。
EGS006 逆变器驱动板用户手册说明书
EG8020 逆变器专用芯片测试板
3.3. EGS006 驱动板背面跳线功能设置
序号
跳线名称 标号
设置说明
JP1 当 JP1 短路,既 HM=“0”时,选择驱动器 2 对应左桥臂控制
1
HM
JP4 当 JP4 短路,既 HM=“1”时,选择驱动器 1 对应左桥臂控制
JP6 当 JP6 和 JP8 同时短路,既 DT1:DT0=“00”时:死区时间为 300ns
EGS006 驱动板能实现空载波形失真率小于 1.5%、满载波形失真率小于 3%和高精度输出电压的特性,能 满足逆变器行业的波形要求。
EGS006 驱动板提供了完善的各项保护功能,提供了直流母线过压和欠压保护、交流输出欠压保护、过 载报警提示、过载保护指示、过流保护指示、过温保护指示及短路保护指示等。
器 4 路通道分别测试 RC 滤波后的输出波形,测到的正确波形如图 4-3,图中 CH1 对应 TEST1 滤波后的 波形,CH2 对应 TEST2 滤波后的波形,CH3 对应 TEST3 滤波后的波形,CH4 对应 TEST4 滤波后的波形。
10K TEST1~TEST4输出分 别接一个RC滤波电路
屹晶微电子有限公司
EGS006 逆变器驱动板用户手册 V1.0
EG8020 逆变器专用芯片测试板
EGS006 正弦波逆变器驱动板用户手册 V1.0
1. 描述
EGS006 是一款基于 EG8020 芯片方案的 SPWM 驱动板,EG8020 是采用电流模式、中心对齐 PWM 调制方式 的数模结合芯片, 专用于高性能逆变器产品。
3.4. LED 运行及故障指示
EGS006 驱动板上采用了绿灯 LED 和红灯 LED 作正常运行及故障指示功能,具体定义如下: 绿灯 LED 长亮、红灯 LED 长灭:该状态指示逆变器正常运行输出,无故障。 绿灯 LED 长亮、红灯 LED 快闪烁:该状态指示逆变器正常运行输出,有过载或过流情况,还 未进入到过载或过流保护状态。 红灯 LED 长亮、绿灯 LED 长灭:该状态指示逆变器进入故障保护模式,用户可通过串口通讯 读取具体的故障代码。
纯正弦波逆变器说明书英文版
Product ManualDC TO ACPower InverterCONTENTSSafety First1.Introduction2.Installation Guidelinesing the inverter4.Troubleshooting5.SpecificationsSafety FirstIncorrect installation or misuse of the inverter may result in danger to the user or hazardous conditions. We urge y0u to pay special attention to all CAUTION and W ARNING statements. CAUTION statements identify conditions or practices that may result in damage to other equipment. WARNING statements identify conditions that may result in personal injury or loss of life.WARNING! Shock hazard. Keep away from children.●The inverter generates the same potentially lethal AC power as a normal household walloutlet. Treat it with the same respect that you would and AC outlet.●Do not insert foreign objects into the inverter’s AC outlet, fan or vent openings.●Do not expose the inverter to water, rain, snow or spray.●Do not under any circumstances, connect the inverter to utility power AC distribution wiring. WARNING! Heated surface.●The inverter’s housing may become uncomfortably warm, reaching 140℉(60℃)underextended high power operation. Ensure at least 2 inches (5cm) of air space is maintained on all sides of the inverter. During operation, keep away from materials that may be affected by high temperatures.WARNING! Explosion hazard.●Do not use the inverter in the presence of flammable fumes or gases, such as in the bilge of agasoline powered boat, or near propane tanks. Do not use the inverter in an enclosure containing automotive-type, lead-acid batteries. These batteries, unlike sealed batteries, vent explosive hydrogen gas, which can be ignited by sparks from electrical connections.●When working on electrical equipment always ensure someone is nearby to help you in anemergency.CAUTION!●Do not connect live AC power to the inverter’s AC outlets. The inverter will be damagedeven if it is switched OFF.●Do no connect any AC load, which has its neutral conductor connected to ground, to theinverter.●Do not expose the inverter to temperatures exceeding 104℉(40℃).CAUTION! Do not use inverter with the following equipment.●Small battery operated product such as rechargeable flashlights, some rechargeable shavers,and night-lights that are plugged directly into and ac receptacle to recharge.●Certain battery chargers for battery packs used in hand powered tools. These chargers willhave warning labels stating that dangerous voltages are present at the charger’s battery terminals.●Connect inverter only to batteries with a 12/24V/48V DC nominal output. A battery with6V/12/24V nominal output will not supply enough voltage and a battery with 24V/24V/96V nominal output will DAMAGE THE INVERTER.1.IntroductionThank you for purchasing the power inverter. The inverter is a compact and highly portable power inverter, the leader in the field of high frequency inverter design. From the 12V/24V/48V DC outlet in you vehicle or boat, or directly from a dedicated 12V/24V/48V DC battery, the inverter will efficiently and reliably power a wide variety of household AC products ,such as TVs, computers, VCRs, and includes automatic safety monitoring circuitry to protect the inverter, and your battery, from inadvertent overload conditions.Read this guide before installing or using the inverter and save it for future reference.Safety FeaturesThese advanced safety features are built into the inverter:●Electronic overload protection with automatic shutdown.●Built-in internal backup DC fuse provides added safety.●Low battery voltage protection with automatic shutdown.●Over temperature protection with automatic shutdown.●Output short circuit protection.2.Installation GuidelinesSelecting a Suitable LocationFor safe and optimum performance, install the inverter in a location that is …..●Dry. Do not expose to water drip or spray.●Cool. Operate only in ambient temperatures between 32℉(0℃)and 104℉(40℃). Keepaway from furnace heating vents or other heat producing equipment.●Well ventilated. Allow at least 2 inches (5cm) clearance above and on all sides of the unit forproper cooling.●Safe. Do not install inverter in a compartment with batteries or flammable liquids, such asgasoline, or explosive vapors.●Clean and free of dust and dirt. This is especially important if the inverter is used in a workenvironment.Using the DC Cable-PlugDue to limitations in the common 12V/24V/48V DC outlet in a vehicle or boat, the inverter should only be used to supply AC power to products that require the rated continuous power or less. If you8r application requires more than the rated continuous power (but less than the rated continuous power) or has a high start-up surge, see Using the DC Cable-Clips.1.Attach the ring type connector marked with red to the positive (+) DC terminal on the inverterand attach the ring connector marked with black to the negative (-) DC terminal.CAUTION! A reverse polarity connection (positive to negative) may damage the inverter. Damage caused by a reverse polarity connection is not covered under warranty.2.Tighten the nut on each DC terminal by hand until it is snug. Do not over tighten.3.Insert the plug of this cable into the 12V/24V/48V DC outlet and switch the unit ON. SeeSection 4 if the inverter does not operate properly after being connect.4.When the inverter is not in use, unplug it from the 12V/24V/48V DC outlet to prevent slightdischarge of the Battery.Instruction of structureInstruction of operationUsing the Dc cable-ClipsBy directly connecting the inverter to a 12V/24V/48V DC battery with DC Cable-Clips, you can operate products with power requirements up to rated continuous output power. If you want to permanently connect the inverter to a battery, contact the customer service.1.Follow steps 1 and 2 above (Using the DC Cable-Plug) to attach the ring type connectors.2.Attach the black negative clip to negative (-) battery terminal.3.Attach the red positive clip to the positive (+) battery terminal. Make sure both clips aresecurely connected to the battery terminals, as a loose connection will cause excessive voltage drop and may cause the cables to overheat resulting in equipment damage or fire.4.Switch the inverter ON. See section 4 if the inverter does not operate properly after beingconnected.5.When the inverter is no in use, disconnect the DC Cable-Clips from the battery.ing the inverterThe inverter is capable of continuously powering most 110V/230V AC products that use the rated continuous output power or less. Its AC output waveform, called”modified sine wave/pure sine wave “is designed to function as wave shape of utility power or more beautiful than city electricity.The power, or “wattage”, rating of ac products is the average power they use. When many AC products are first switched on, they initially consume more power than their power rating. TVs, monitors, and electric motors are examples of products that have high “surge”requirements at start up. Although the inverter can supply momentary surge power as high as surge power, occasionally some products rated less than the rated continuous output power may exceed its surge capabilities and trigger its safety overload shutdown feature. If this problem occurs when attempting to operate several AC products at the same time ,try first switching on inverter with all AC products switched off ,then one by one switch each on, starting with the high surge product first.Indicators and Controls (See Figure 1)●The AC outlets are provided on one end of the inverter. Any combination of 110V/230V ACproduct with a total continuous power consumption of the continuous power or less may be plugged in.●The ON/OFF switch enables output AC power at the AC outlets when switched ON.●The green POWER light indicates AC power is present at the AC outlets and the inverter isoperating normally.●The red FAULT light indicates inverter shutdown caused by low or high voltage, overload orexcessive temperature.Inverter operation1.When properly connected to a 12V/24V/48V DC outlet or battery, turning the ON/OFF switchON, will illuminate the green POWER light, and AC power to the outlets.2.Plug the AC product(s) you wish to operate onto the AC outlet(s) and switch them on, one at atime.3.As the battery charge is used up, battery voltage begins to fall. When the inverter senses thatthe voltage at its DC input has dropped to 10~10.5V/20-21V/40~42V,and audible alarm sounds. This allows time for computers or other sensitive devices to be shut down.4.If the audible alarm is ignored the inverter will automatically shut down when the batteryvoltage drops to 9.8~10.2V/19.6~20.4V/39.2~40.8V. This prevents battery damage from excessive discharge. After auto shut down, the red FAULT light illuminates.IMPORTANT: Vehicle batteries are designed to provide brief periods of very high current needed for engine starting. They are not intended for constant deep discharge. Regularly operating the inverter shortens the life of the battery. Consider connecting the inverter to aseparate deep discharge type battery if you will be frequently running electrical products for extended periods of time.5.If an AC product rated higher than the rated continuous power (or which draws excessivesurge power) is connected, the inverter will shut down .The red FAULT light will turn on.6.If the inverter exceeds a safe operating temperature, due to insufficient ventilation or a hightemperature environment, it will automatically shut down. The red FAULT light will turn on and the audio warning will sound.7.Should a defective battery charging system cause the battery voltage to rise to dangerouslyhigh levels, the inverter automatically shuts down.CAUTION! Although the inverter incorporates protection against over-voltage, it may still be damaged if the input voltage exceeds 16 volts/32 volts/64volts8.The cooling fan is designed to operate only when the temperature is higher than 40℃.9.In the event of an overload, low battery voltage or overheating, the inverter will automaticallyshut down (See Section 4).Battery Operating TimeOperating time will vary depending on the charge level of the battery, its capacity and the power level drawn by the particular AC load.When using a battery as a power source, its is strongly recommended to start the vehicle every hour or two to recharge the battery before its capacity drops too low. The inverter can operate while the engine is running, but the normal voltage drop that occurs during starting may trigger the inverter’s low voltage shut down feature.Because the inverter draws less than the no load current draw with the ON/OFF switch in ON position and with no AC products connected, it has minimal impact on battery operating times.Interference with Electronic EquipmentGenerally, most AC product operate with the inverter just as they would with household AC power. Below is information concerning two possible exceptions.Buzzing Sound in Audio Systems and RadiosSome inexpensive stereo systems, “boom boxes”, and AM-FM radios have inadequate internal power supply filtering and “buzz”slightly when powered by the inverter. Generally, the only solution is an audio product with a higher quality filter.Television InterferenceThe inverter is shielded to minimize its interference with TV signal. However, with weak TV signals interference may be visible in the form of lines scrolling across the screen. The following should minimize or eliminate the problem:●Use an extension cord to increase the distance between the inverter and the TV, antenna andcables.●Adjust the orientation of the inverter, television, antenna and cables.●Maximize TV signal strength by using a better antenna and use shielded antenna cable wherepossible.●Try a different TV. Different models of televisions vary considerably in their susceptibility toinverter.4.Troubleshooting5.SpecificationsAC output voltage (nominal):110V/230V ACDC input voltage range:Nominal 12V:10V-15VNominal 24V:20V-30VNominal 48V:40V-60VAC output frequency:50Hz±2Hz/60Hz±2HzAC output waveform: modified sine wave/pure sine wave Ambient operating temperature range:12℉-130℉/-20℃-65℃Low battery alarm trigger range:Nominal 12V:10V-10.4VNominal 24V:20V-21VNominal 48V:40V-42VLow battery shut down range:Nominal 12V:9.7V-10VNominal 24V:19.4V-20VNominal 48V:40V-42VHigh battery shut down range (nominal):15V/30V/60VCP: Continuous PowerSP: Surge PowerTHD: Total Harmonic DistortionNL: No load Current DrawSpecification subject to change without notice。
EGP1000W(正弦波配套功率驱动板)
GND
U2 7805
C7
C6 Cap
2
EGS001 2
*
EG8010
EGS001
FANCTR 17 TFB 16 VFB 15 +5V 14 GND 13
+12V 12 GND 11 2HO 10 VS2 9 2LO 8 GND 7 VS2 6 VS1 5 GND 4 1LO 3 GND 2
IFB 1
不接
外接
12V‐15V
不接
不接
15V‐25V
不接
不接
25V‐75V
不接
不接
表 3‐1 工作模式与电源配置表格
不焊
不焊 L7812 EG1181 不焊 L7812 EG1181
跳线 JP1
断开
断开 断开 断开 断开 短接 短接 短接
跳线 JP2
断开
断开 断开 短接 短接 短接 短接 短接
跳线 JP3
断开
R1 3.3K
C5
C4 Cap
P1
1 FAN_VCC
2 GND
外挂风扇电源接口
散热风扇
F2
FAN
1
2
2 2
U1 1 VIN +12V 3
EG1181 GND 电源模块
C9
C8 0.1uF/25V
D1
+5V
1 VIN +5V 3 GND
R2
大于45°C开启风扇
U2 7805
C7
C6 Cap
2.2K
风扇控制
风扇电源(P1)主要为散热风扇提供电源,由于散热风扇的工作电压不同,一般风扇电源需要外接,工作 在工频模式时,也可通过配置跳线 JP2 选择功率电源为散热风扇供电。
EES-001 使用說明書说明书
使用說明書歐頓變頻微晶電磁爐SUNIN YOUR HOUSE V1.0◎當發生異常或有燒焦味時,應立即拔除電源插頭,若在異常狀態下繼續使用,易造成火災之發生。
◎請速與本公司服務專線聯絡或就近經銷商洽詢。
EES-001目錄(一)免責聲明 (1)(二)緊急處理方法 & 警告 (2)(三)安全注意事項 (2)(四)各部位名稱與組裝方法 (3)(五)本機特點 (4)(六)規格 (4)(七)使用鍋具注意事項 (4)(八)使用方法 (5)加熱 (5)加速 (5)定溫 (6)定時功能 (6)煎炸功能 (7)煮飯功能 (7)預約煮飯功能 (7)煮飯功能米量/水量關系表 (8)關機狀態 (8)特別說明 (8)(九)故障代碼 (9)(十)簡易故障排除 (10)(十一)清潔與保養方法 (10)●聲明:本手冊業經仔細檢查及校對,但仍不排除文字拼寫及技術錯誤之可能,若因錯誤導致與實機不符時,以實機為準,此種錯誤或疏漏不能當呈堂的依據,其將於新版予以修正。
本手冊之全部內容,本公司享有隨時修改之權力,且不另行通知。
12在使用本機之前,應仔細閱讀下列事項及使用說明,閱後請妥為收存,以備將來參考:1.插頭、電源線請勿觸碰到水或其他液體或勿附著灰塵,以防止觸電及短路。
2.使用時,請遠離瓦斯爐或煤油爐等發熱源,因周圍溫度升高,可能停止加熱。
3.收音機、電視機、錄放影機放置過近,使用時有可能引起干擾現象。
4.請勿將對磁性敏感反應的手錶、信用卡,磁卡等物品放置於本機附近,以免引起 消磁等現象。
5.機器使用時需水平置放平坦表面,且須預留10CM散熱空間。
6.機體及附件表面,可使用中性洗劑及軟布擦拭,請勿使用高揮發性清潔劑,且不 可直接用水沖洗機體,以免機體浸水而發生故障。
7.本機建議單獨使用專用插座或延長線(需耐15A)且不可與其他電器共用插座。
8.陶瓷板上不可以鋁箔、紙張、布等物品直接或間接加熱, 並不可放置或烹煮調理 鍋以外的金屬物品,如未開啟的罐頭經加熱後,有可能引起爆炸的危險。
纯正弦波逆变器H桥专用驱动板使用简介
纯正弦波逆变器H桥专用驱动板使用简介一、主控板V1.2版图片:功能选择区2二、纯正弦波逆变器H桥专用驱动板功能说明:1、采用高性能32位单片机,输出波形精度高,稳压性能好,各种保护功能。
2、5V 、+15V电源供电3、引脚设置50Hz纯正弦波固定频率 60Hz纯正弦波固定频率4、双极性调制方式。
5、自带死区控制,引脚设置4种死区时间: 500nS死区时间 1uS死区时间 1.5uS死区时间 2.0uS死区时间可通过跳线选择,通过上位机软件可以设置最大为3uS。
6、 PWM载波频率20K、25K可选,频率越高,波形越好,但是相对来说开关损耗也越大,这个根据需要可以通过跳线选择。
7、H桥驱动芯片为IR2113S,600V 2A,比2110耐压高,耐冲击。
8、电压反馈为真有效值采样,不论任何负载,电压的稳定度均在+-2%内。
9、输出电压过压、欠压保护可用跳线选择开启或关闭。
方便初期调试,调试完工后再打开此功能即可。
10、软启动可用跳线选择开启和关闭。
12、无负载自动休眠功能,可以通过跳线选择开启和关闭。
13、所有保护停机,自动重启动能,可以通过跳线选择开启和关闭。
14、可长期短路,短路取消后在5秒内电压自动恢复。
15、独立的电压调整模拟量输入,实现输出电压真正的从0V起调。
15、与上位机软件配合,所有用户参数和设置,都可以随意修改,更改后会自动保存,下次启动会以上次设置参数运行。
三:驱动板指示灯接口及控制接口说明:J15为与功率板对接接口:PIN1:CUR_I ,为霍尔电流传感器输入。
PIN2:VOLT_ADJ ,输出电压调整电位器输入,交流输出的电压随输入电压的变化而变化,可以控制输出电压从0V 起调。
PIN 3:+5V 电源。
PIN 4:GND ,电源地。
PIN 5:VFB2,交流电压采样二。
PIN 6:TFB ,温度传感器输入(10K 负温度系数热敏电阻)PIN 7:VFB ,交流电压采样一。
PIN 8:FAN_OUT ,风扇自动控制输出。
逆变器操作说明及故障处理
一逆变器原理介绍1.1逆变(invertion):把直流电转变成交流电的过程。
逆变电路是把直流电逆变成交流电的电路。
当交流侧和电网连结时,为有源逆变电路。
变流电路的交流侧不与电网联接,而直接接到负载,即把直流电逆变为某一频率或可调频率的交流电供给负载,称为无源逆变。
逆变桥式回路把直流电压等价地转换成常用频率的交流电压。
逆变器主要由晶体管等开关元件构成,通过有规则地让开关元件重复开-关(ON-OFF),使直流输入变成交流输出。
当然,这样单纯地由开和关回路产生的逆变器输出波形并不实用。
一般需要采用高频脉宽调制(SPWM),使靠近正弦波两端的电压宽度变狭,正弦波中央的电压宽度变宽,并在半周期内始终让开关元件按一定频率朝一方向动作,这样形成一个脉冲波列(拟正弦波)。
然后让脉冲波通过简单的滤波器形成正弦波。
1.2 IGBT的结构和工作原理1.2.1 IGBT的结构IGBT是三端器件,具有栅极G、集电极C和发射极E。
IGBT由N沟道VDMOSFET 与双极型晶体管组合而成的,VDMOSFET多一层P+注入区,实现对漂移区电导率进行调制,使得IGBT具有很强的通流能力。
图1-1为IGBT等效原理图及符号表示图1-1 IGBT等效原理图及符号表示1.2.2IGBT的工作原理IGBT的驱动原理与电力MOSFET基本相同,是一种场控器件。
其开通和关断是由栅极和发射极间的电压U GE决定的。
当U GE为正且大于开启电压U GE(th)时,MOSFET内形成沟道,并为晶体管提供基极电流进而使IGBT导通。
当栅极与发射极间施加反向电压或不加信号时,MOSFET内的沟道消失,晶体管的基极电流被切断,使得IGBT关断。
电导调制效应使得电阻R N减小,这样高耐压的IGBT也具有很小的通态压降。
1.3逆变电路介绍1.3.1逆变产生的条件为1,要有直流电动势,其极性须和晶闸管的导通方向一致,其值应大于变流器直流侧的平均电压。
2要求晶闸管的控制角α>π/2,使U d为负值。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
EGS001正弦波逆变器驱动板用户手册
EGS001正弦波逆变器驱动板用户手册
EGS001 是一款专门用于单相纯正弦波逆变器的驱动板。
采用单相纯正弦波逆变器专用芯片EG8010 为控制芯片,驱动芯片采用IR2110S。
驱动板上集成了电压、电流、温度保护功能,LED 告警显示功能及风扇控制功能,并可通过跳线设置50/60Hz 输出,软启动功能及死区大小。
EG8010 是一款数字化的、功能很完善的自带死区控制的纯正弦波逆变发生器芯片,应用于DC-DC-AC 两级功率变换架构或DC-AC 单级工频变压器升压变换架构,外接12MHz 晶体振荡器,能实现高精度、失真和谐波都很小的纯正弦波50Hz 或60Hz 逆变器专用芯片。
该芯片采用CMOS 工艺,内部集成SPWM 正弦发生器、死区时间控制电路、幅度因子乘法器、软启动电路、保护电路、RS232 串行通讯接口和12832 串行液晶驱动模块等功能。