科视欧几里德角膜塑形镜产品技术手册
P040029b欧几里得角膜塑形镜
![P040029b欧几里得角膜塑形镜](https://img.taocdn.com/s3/m/6eff82de7f1922791688e8e9.png)
Iห้องสมุดไป่ตู้.
INDICATIONS FOR USE Euclid Systems Orthokeratology (oprifocon A) Contact Lenses for Overnight Wear are indicated for use in the reduction of myopic refractive error in non-diseased eyes. The lenses are indicated for overnight wear for the temporary reduction of myopia up to 5.00 diopters with eyes having astigmatism up to 1.50 diopters. The lenses may only be disinfected using a chemical disinfection system. Note: To maintain the Orthokeratology effect of myopia reduction, overnight lens wear must be continued on a prescribed schedule. Failure to do so can affect daily activities (e.g., night driving), visual fluctuations and changes in intended correction.
III.
Center for Devices and Radiological Health (CDRH) Decision This application includes by reference the data in PMA P010062 for the Euclid Systems Orthokeratology (oprifocon A) Contact Lenses for Overnight Wear by Euclid Systems Corporation approved on June 7, 2004. Euclid Systems Corporation has given Szabocsik and Associates a license right to incorporate by reference the information contained in its approved PMA P0 10062. Euclid Systems Corporation will be the manufacturer of the JSZ Orthokeratology (oprifocon A) Contact Lenses for Overnight Wear. CDRH approval of the Szabocsik
ok镜美国已经禁止了
![ok镜美国已经禁止了](https://img.taocdn.com/s3/m/8bd9641c640e52ea551810a6f524ccbff121cacd.png)
ok镜美国已经禁止了ok镜美国已经禁止了2022年央视3·15晚会就曝光了这样一起案例,他们假冒医生,穿上白大褂,大摇大摆地进入学校,为学生体检,搜集孩子家长的信息,最终达到谋取利益的目的。
郑州市科视视光技术有限公司在一家招聘网站上,招聘兼职体检员,工作内容是“郑州市中小学校学生视力体检”,工作地点是“郑州市各中小学”。
没有任何医学背景,也没有经过任何面试,科视公司就直接与记者签订了一份兼职体检员的劳动合同。
入职培训唯一的内容就是体检队队长教大家如何详细填写“河南省中小学生健康检查表”郑州市科视视光技术有限公司体检队孙队长:几年级你就填几年级,一定不能填错了。
ok镜美国已经禁止了第二天一早,记者来到了集合地,出发前,记者向此次体检带队的孙队长再次强调自己没有任何医学基础,孙队长对此毫不在意。
孙队长:谁是专业的记者:都不是专业的。
ok镜美国已经禁止了孙队长:你就随便指巴两下就算了,说句难听点我们就是出去玩儿。
记者和一群体检员乘坐大巴来到了郑州市管城区的南曹小学,体检员们搬着体重秤,身高尺等体检器材进入了学校。
准备工作就绪后,有的体检员从自己的包里取出白大褂穿上,然而包括记者在内的另外一些人的白大褂则是由孙队长一一发放的。
视力检查组的五个人,都是科视公司招聘的,他们有学面料设计的,有学法律的,竟然没有一个人有医学专业背景。
体检队的孙队长告诉大家,如果有人问起体检单位,就称自己是黄河科技学院附属医院体检队的。
记者发现每一位检查完视力的孩子,无论视力好坏,都会被科视公司的工作人员带到桌边填写一张“视力异常登记表”。
孩子们要填写自己的姓名,家长手机号等信息。
这一天南曹小学参加体检的一千多名学生都被要求填写了“视力异常登记表”。
第二天体检的学校是管城区席村小学,这所小学五百多名学生在检查完视力之后,也都被要求填写了“视力异常登记表”。
在这张“2022年管城区区属中小学校学生体检时间安排表”上,记者看到从2022年11月21号到12月26号,科视公司一共要为郑州市管城区42所学校的约五万名学生进行体检。
角膜塑形镜使用说明书
![角膜塑形镜使用说明书](https://img.taocdn.com/s3/m/0b12bb35a517866fb84ae45c3b3567ec102ddcd1.png)
角膜塑形镜使用说明书简介角膜塑形镜是一种特殊的隐形眼镜,也被称为角膜塑形镜片或角膜塑形器。
它通过改变角膜曲率来矫正近视、远视等视力问题。
角膜塑形镜与传统的隐形眼镜有些不同,它的设计可以改变角膜表面的形状,使光线正确地聚焦在视网膜上,从而提供清晰的视觉。
本使用说明书将为您提供使用角膜塑形镜的详细指导,包括佩戴前的准备、佩戴和护理步骤,以及一些注意事项。
一、佩戴前的准备在佩戴角膜塑形镜之前,您需要进行以下准备工作:1.请确保您的眼睛和手部清洁:用温水和适宜的无菌肥皂或洗手液洗净双手,并用干净柔软的毛巾擦干。
确保没有任何污垢或细菌留在手部。
然后,使用角膜塑形镜专用的清洁液清洗眼镜。
2.戴隐形眼镜之前请揉磨眼镜:将隐形眼镜放在手掌中,滴上适量的隐形眼镜护理液,用无名指将眼镜来回揉磨数次。
这有助于清洁镜片并去除残留的蛋白质和污垢。
3.咨询眼科医生或验光师:在佩戴角膜塑形镜之前,请咨询专业的眼科医生或验光师,确保您的眼睛适合使用角膜塑形镜。
二、佩戴步骤以下是佩戴角膜塑形镜的步骤:1.取出角膜塑形镜:用手洗净并擦干后,取出一只角膜塑形镜,并将其放在干净的指尖上。
确保不要用指甲直接接触镜片表面,以防刮伤。
2.将角膜塑形镜放置在眼球上:用另一只手的无名指轻轻拉下下眼睑,用中指将角膜塑形镜轻轻放置在角膜上。
请确保正确定位,并注意不要将角膜塑形镜放倒。
3.检查透明度和舒适度:完成佩戴后,闭上眼睛并轻轻眨眼,以确保角膜塑形镜的透明度和舒适度。
如果感觉不适或模糊,请进行必要的调整。
4.重复以上步骤:重复上述步骤,将另一只角膜塑形镜佩戴在另一只眼睛上。
确保正确安装和调整。
5.眼镜佩戴时间选择:初次佩戴角膜塑形镜时,建议缓慢适应,每天佩戴时间逐渐增加。
根据医生或验光师的建议,您可以选择白天佩戴或夜间佩戴。
根据个人情况定期复查并调整佩戴时间。
三、护理步骤正确的护理是使用角膜塑形镜的关键。
以下是护理步骤的建议:1.每日清洁:每天使用特制的清洁液和护理剂清洁角膜塑形镜。
角膜塑形镜使用说明书 (3)
![角膜塑形镜使用说明书 (3)](https://img.taocdn.com/s3/m/5cebdad5dc88d0d233d4b14e852458fb770b3813.png)
角膜塑形镜使用说明书
角膜塑形镜是一种视力矫正器具,可以矫正近视、远视和散光等视力问题。
下面是角膜塑形镜使用说明书的基本内容:
1. 清洁双手,确保其干净且无残留物。
2. 在使用角膜塑形镜之前请使用角膜润滑液进行润滑。
3. 取出镜片,并将之放在干净的手心中。
4. 使用指尖将镜片从手心拿起,轻轻地将其放在眼角膜上方。
5. 确保镜片平整地附着在眼角膜上,并不会移动或滑动。
6. 留意是否存在空气泡,如有需要及时排除。
7. 重复以上步骤来放置另一只镜片在另一只眼睛上。
8. 使用倒立冰箱放置角膜塑形镜,放在保存盒中,使用保存液进行保存。
9. 每天早上取出角膜塑形镜,并使用角膜润滑液将其清洗
干净。
10. 每天使用前请先进行视力检查,以确保角膜塑形镜仍然适合您的视力矫正需求。
11. 根据您的眼睛专业人员或医生的建议进行日常使用时间,以避免眼睛疲劳或不适。
12. 如有任何不适或不正常症状出现,请立即停止使用,并咨询眼科专业人员或医生的建议。
请注意,以上只是一般的使用说明,具体的使用方法和注
意事项可能会因产品型号和个人情况而有所不同。
在使用
角膜塑形镜之前,最好是咨询眼科专业人士的意见和建议。
ok镜 说明及注意事项
![ok镜 说明及注意事项](https://img.taocdn.com/s3/m/655db625482fb4daa58d4b08.png)
OK镜(角膜矫形镜)小常识OK镜,又称角膜矫形镜,实际上是一种特殊的隐形眼镜,它能使近视患者白天不用配戴框架眼镜或者隐形眼镜,亦不需要手术,就提高视力。
OK镜的配戴类似于普通隐形眼镜,夜间配戴,晨起后取下,利用睡眠时镜片对眼球的矫形作用,使近视度数降低。
大约十多天后在不戴眼镜的情况下,获得稳定的正常视力。
持续配戴还有可以阻止青少年近视的发展。
OK镜能消除配戴框架眼镜所带来的许多不便,也避免了近视矫正手术的诸多风险,提高了患者的生活质量。
它特别适合于某些特殊途职业者,譬如运动员、演员、飞行员、潜水员、消防员、警察等。
在使用OK镜片之前请仔细阅读使用说明书,并遵守医嘱。
本院建议您在充分了解有关知识的基础上,在专业眼科医生的指导下谨慎地使用本治疗方法。
对本方法有怀疑者,请不要勉强采用OK镜治疗。
一、ORTHOKERATOLOGY 角膜矫正术的一般知识:传统光学眼镜和近年来风行的软性接触式隐形眼镜,虽然给近视患者在生活、学习和工作上带来了很大的便利,但由于受材料和配戴方式的限制无法降低患者的近视度数,更不可能阻止患者近视程度的进一步加深,特别是青少年患者。
另外,软性隐形眼镜因为其材料是PMMA(这种材料不允许氧气通过),只能借助其高含水量的特性,通过水份或泪液来传递氧气给角膜。
如果配戴软性镜片,长时间位于电脑或电视的屏幕前,电子射线很容易导致其水份的蒸发,从而引起眼睛感觉不适。
ORTHOKERATOLOGY 角膜矫正术是近三年来,在美国首先开展起来的一种治疗和控制近视的临床医疗方法。
它得益于新材料和电脑科技在测量、加工过程中最新应用,使眼科医生能够在可预计和可控制的条件下,对近视患者进行安全、有效地临床治疗和控制青少年近视的进一步加深。
应该特别指出,这种方式的出现改变了眼科医生对青少年近视"束手无策"的局面,当然它本身仍需要在临床实践中进一步的发展和经受检验。
早在四十年代,美国的科学家便开始寻找非手术方法降低近视的度数。
《角膜塑形镜》PPT课件
![《角膜塑形镜》PPT课件](https://img.taocdn.com/s3/m/f7e6e64fd1f34693daef3ee8.png)
A
11
经营单位和验配机构应提供经国家药品监督管理局批准的产品使用说明书
A
12
关于印发角膜塑形用硬性透气接触镜说明书编写指导原则的通知 (食药监办械函[2011]143号)
A
13
说明书内容至少包括: (一)客观如实地介绍角膜塑形镜的矫治原理,并说明角膜塑形镜的作用是暂时的、有限的, 疗效是可逆的。 (二)明确产品适用的视力矫正范围、适应人群。 (三)明确禁忌症、注意事项。 (四)告知配戴者可能会出现的反应或症状,如:眼部刺激、发痒、不适、眼中有异物感或擦 伤感、眼部发红、惧光、出现异常分泌物等;告知配戴者遇到不适时应当采取的措施,如:摘 下镜片,及时到医院就诊等。 (五)明确与该产品配套使用的清洗、消毒与护理液。
角膜塑形镜
A
1
关于角膜塑形镜的相关文件共有4个。
A2ຫໍສະໝຸດ 一、关于印发《角膜塑形镜经营验配监督管理规定》的通知(国药监市〔2001]326号) 二、关于角膜接触镜不属于植入医疗器械的通知(国食药监械[2005]490号 ) 三、关于印发接触镜护理产品注册技术审查等9项指导原则的通知(食药监办械函[2011]116号) 四、关于印发角膜塑形用硬性透气接触镜说明书编写指导原则的通知(食药监办械函[2011]143 号)
A
8
角膜塑形镜验配机构,是指直接为屈光不正患者检查验光,使用角膜塑形镜为配戴者矫正裸眼 视力,具有法人资格的机构,包括医疗机构设置的验配部门或专业验配机构。角膜塑形镜验配 机构,是指直接为屈光不正患者检查验光,使用角膜塑形镜为配戴者矫正裸眼视力,具有法人 资格的机构,包括医疗机构设置的验配部门或专业验配机构。
A
4
角膜接触镜不符合植入器械的定义,不是植入医疗器械,是长期接触角膜的Ⅲ类医疗器械。
科视欧几里德角膜塑形镜产品技术手册
![科视欧几里德角膜塑形镜产品技术手册](https://img.taocdn.com/s3/m/3bcc72838762caaedd33d44f.png)
科视产品技术手册内容表前言一、近视眼的相关知识二、角膜塑形镜基础知识三、角膜塑形镜的适应症与非适合人群四、角膜塑形镜的验配五、角膜塑形镜的订制六、患者培训七、复查与随访服务八、角膜塑形镜的配适不良及并发症处理九、角膜塑形镜矫治近视工作流程十、档案资料管理十一、结语十二、参考文献附件:1、矫治近视基本资料登记表2、复查记录3、角膜塑形镜配戴协议4、角膜塑形镜订单5、经营资质证件前言这是一本教育性手册,目的是概括介绍使用特别设计的角膜塑形镜矫治近视的情况,内容包括角膜塑形学的原理和戴镜流程。
学习验配角膜塑形镜的课程。
一、近视眼的相关知识近视已标志为影响人类最普遍的眼睛问题之一,并且仍作为全球性增长之中的问题,一个全球性现象是标志一个国家工业化及教育水平的提高。
近视发病率也在增加,发病率在不同的国家有所不同,从美国的低至25%到高至中国某些地区的90%,这使很多国家的政府和卫生组织很关注近视对市民影响。
具体如下表:1、何为近视眼近视眼就是远处的平行光线进入眼睛通过角膜等器官折射,焦点不能落在视网膜上,而是落在视网膜前方。
2、近视眼的分类:(1)按度数分:轻度:<-3.00D中度:-3.00~-6.00D高度:>-6.00D(2)按调节分:假性(调节性近视)真性混合性(部分假性近视存在)(3)按病因分:轴性屈光性(曲率性、屈折指数性)(4)按性质分:单纯性病理性3、近视眼的患病率:全球近视患者10亿,我国近视眼患者3亿。
亚洲为高发地区(中国、日本、韩国、新加坡)欧美较低,非洲最低。
与种族、性别、年龄、地区、环境等因素有关。
4、近视眼的发病原因:(1)遗传因素(2)环境因素传统调节理论——长期过度近距离用眼(应试教育、现代生活)其他因素:污染、营养、微量元素等5、近视眼的危害(1)视力障碍(2)视疲劳(3)外隐斜或外斜视(4)眼轴变长,飞蚊症(5)眼底改变,豹纹眼底、黄斑出血、视网膜脱离、巩膜葡萄肿等。
PPT角膜塑形镜教学讲义PPT
![PPT角膜塑形镜教学讲义PPT](https://img.taocdn.com/s3/m/44bf57a1b9f67c1cfad6195f312b3169a451eacf.png)
佩戴与维护
佩戴指导
向患者详细介绍正确的佩 戴方法和注意事项。
日常维护指导
指导患者如何清洗、存储 和更换镜片,以及如何处 理常见问题。
定期复查
要求患者定期回诊复查, 以确保眼部健康和镜片适 配度。
角膜塑形镜常见问
04
题与解答
佩戴不适
佩戴不适的原因
可能是由于镜片配适不良、镜片污垢或沉淀物过多、镜片破损等情况引起的。
矫形镜片在夜间佩戴时,通过泪液产生的流体静压力作用在角膜上,逐渐改变角膜 形状。
矫形过程
矫形过程通常在夜间进行,白 天摘下镜片后,角膜保持新的 形状,减少或消除近视度数。
矫形镜片需要定制,根据佩戴 者的近视度数、角膜曲率等参 数进行个性化设计。
矫形镜片需要定期更换,以保 证矫形效果和眼睛健康。
矫形效果
特点
03
04
05
夜间佩戴,白天摘下后 视力清晰。
长期佩戴可减缓近视度 数增长。
需要专业验配和定期复 查。
历史与发展
01
02
03
1960年代
角膜塑形镜的初步概念提 出。
1990年代
现代角膜塑形镜技术诞生 。
2000年代至今
技术不断完善,应用越来 越广泛。
适用人群
年龄
8岁及以上,近视度数增长过快或 对白天视力有较高要求的青少年 。
PPT角膜塑形镜教学
06
案例分享
案例一:青少年近视控制
患者情况
一位12岁的男孩,近视度数逐年 增长,家长担心孩子近视度数过
高影响未来职业选择。
治疗方案
为患者定制适合的PPT角膜塑形 镜,通过夜间佩戴,白天达到清
晰视力。
治疗效果
角膜塑形镜验配技术-(第一章、了解角膜塑形镜和镜片基本参数测测量
![角膜塑形镜验配技术-(第一章、了解角膜塑形镜和镜片基本参数测测量](https://img.taocdn.com/s3/m/6b826a6d00f69e3143323968011ca300a6c3f6f3.png)
角膜塑形镜验配技术-(第一章、了解角膜塑形镜和镜片基本参数测测量角膜塑形镜验配技术-基础篇学习指导前言若问,角膜塑形镜与普通的角膜接触镜的区别在哪里?我个人认为在于这个“塑”字,角膜塑形镜戴在角膜上,是人们刻意地用其去改变角膜的形状,使之变平坦,但这种改变不是随意性或随机性,而是依据预先严谨的设计“塑造”出来,达到预期目标,所以称之过程或行为为“角膜塑形术”(orthokeratology,OK)。
也有另外一些表述,如角膜重塑治疗( corneal reshaping therapy,CRT),从中可以看出它的医疗属性。
在结构十分精密但又非常脆弱的角膜面上做“塑形”,需要多方面的知识准备,既要了解眼晴的解剖生理和病理,又要了解眼睛的光学结构和屈光机理,同时还必须熟悉镜片的材料和设计。
不仅如此,角膜塑形是一个动态的过程,对于该过程的掌控必须是有预测、有实时评估、有安全有效的监控等。
由此可见,角膜塑形术是接触镜验配领域更具挑战的内容。
作为历经几十年的角膜塑形术,具备其独特的临床意义,即能在特定的角膜条件下、一定的近视量范畴内、有效地可逆地降低近视度数。
而随着人们对角膜安全监控技术的发展、镜片材料和设计的技术突破,角膜塑形术的安全和有效得到进一步证实。
不少临床医师开始尝试角膜塑形镜的验配,对于初学者来说,起步时的“导师”莫过于有一本简洁、明了、浅显易懂、依据临床思维循序渐进的实训手册本角膜塑形术实训手册应运而生。
参与本实训手册的作者都是来自临床一线的年轻医师,我们这些医师,虽然年轻,但却亲历了从学学习、实践、学习,逐步熟练,实力呈现,但又不断挑战自我的境界。
本手册的撰写也凝聚了不少资深专家和朋友的帮助,谢培英教授多次给予指点,退蕙、郭曦老师参与大量整理和校对工作,毛欣杰副教授指导审阅了相关图片和资料,张浩老师参与一些实验图片的拍摄工作,卓然医生参与画图工作。
在此,向所有关心、支持和参与本教材工作的专家和同事再次一并表示衷心感谢。
欧几里德角膜塑形镜课件ppt1
![欧几里德角膜塑形镜课件ppt1](https://img.taocdn.com/s3/m/897cbad95a8102d277a22f01.png)
4.等离子覆膜
• 去除镜片加工残留物 :初次使用时,镜 片容易清洗,容易湿润
• 增加镜片表面的光滑度 :进一步改善戴 镜舒适度和安全性
• 赋予镜片表面保护膜 :防止在运输、清 洗处理时对镜片表面不慎损伤
5.激光标记
• 镜片外表面边缘统一编码 :起到防伪作 用,每一个用户可以通过互联网辨别镜 片真伪
欧几里德角膜塑形镜
近视眼发生率日益增加
近视眼的发生率在我国居高不下,根据 流行病学调查证实: 我国近视眼的人群患病率超过33% 小学生检出率为32.5% 初中生检出率为59.4% 高中生检出率为77.3% 大学生检出率为80%以上
近视眼发生的原因
• 近视眼的发生和发展与遗传因素相关, 根据遗传学研究证实:
• 戴镜2年度数未增长
例2:王某某,女,8岁, 验光:R:-2.50D L:-2.25D
• 于日开始佩戴 欧几里德角膜塑形镜,复查: • 第1天: R :1.2 L:1.2 • 第1周: R:1.5 L:1.5 • 第1个月: R:1.5 L:1.5 • 第3个月: R:1.5 L:1.5 • 第6个月: R:1.5 L:1.5 • 第12个月:R:1.5 L:1.2 • 第18个月:R:1.5- L例4:牛某某,女,15岁, 验光:R:-6.25D L:-6.00-0.50*141
• 于日开始佩戴 欧几里德角膜塑形镜,复查: • 第1天: R :0.6 L:0.5 • 第1周: R:0.7 L:0.5 • 第1个月: R:0.9 L:1.2 • 第3个月: R:1.0 L:0.7(左眼因异物入眼停戴) • 第12个月:R:1.0 L:0.9 • 第18个月:R:0.9 L:1.0 • 第24个月:R:1.5 L:1.5
• 内表面结构分布合理 :使戴静容易适应, 且改善戴镜的舒适性
角膜塑形镜说明书
![角膜塑形镜说明书](https://img.taocdn.com/s3/m/d00703cbb9f3f90f76c61b20.png)
附件:角膜塑形用硬性透气接触镜说明书编写指导原则角膜塑形用硬性透气接触镜(以下简称角膜塑形镜)说明书承载了产品预期用途、配戴步骤、警示、注意事项等重要信息,是指导配戴者正确操作、眼科专业人员准确理解和合理应用的重要技术性文件。
本指导原则基于国家食品药品监督管理局《医疗器械说明书、标签和包装标识管理规定》的有关要求,参考国外监管机构的经验及生产企业有关角膜塑形镜说明书编写方面的资料,对说明书的编写格式及各项内容进行了详细的说明。
其目的是为编写角膜塑形镜说明书进行原则性指导,同时,也为注册管理部门审核说明书提供技术参考。
由于产品特点、配戴环境和配戴者条件不同,产品说明书的内容可能不尽完全相同。
如果没有合理的理由和充分依据,各角膜塑形镜的说明书应当按照本指导原则的格式和内容,根据批准条件、产品特点及临床使用目的等情况进行编写。
说明书的字号比例应当与指导原则一致,无论采用彩色或单色印刷,色彩对比均需清晰一致,以便于相关人员获取准确的信息。
一、角膜塑形镜说明书格式角膜塑形镜说明书【注册号】【通用名称】【英文名称】【商品名称】【型号】【执行标准】【注册日期】【说明书批准及修改日期】【管理类别】【特别提示】【警示】【作用与用途】【适用范围】【适用人群】【禁忌症】【配戴时间】【加工方式、制成材料与颜色、结构等】【包装内部件】【护理用品】【配戴注意事项】【镜片配戴、摘取方法】【镜片的护理、存放】【护理液使用注意事项】【镜片盒使用注意事项】【不良事件】【储存条件、有效期】【生产企业】【国内代理人】(进口产品适用)【国内售后服务机构】(进口产品适用)二、各项内容撰写的说明【注册号】注明该产品的注册证书编号。
【通用名称】注明:角膜塑形用硬性透气接触镜(以下简称角膜塑形镜)。
【英文名称】注明:Rigid gas permeable contact lenses for orthokeratology。
【商品名称】商品名称的文字不得大于通用名称文字的两倍。
角膜塑形镜验配的相关法规和标准流程PPT课件
![角膜塑形镜验配的相关法规和标准流程PPT课件](https://img.taocdn.com/s3/m/c6a7cb5af12d2af90242e6ab.png)
特此复函。 二O一一年十一月八日
关于停发角膜塑形镜验配医疗器械经营企业许可证的通知
苏食药监械〔2012〕2号
现将国家食品药品监管局医疗器械监管司《关于角膜塑形镜验 配有关问题的复函》(食药监械函〔2011〕80号)转发给你们,同 时按照《关于印发角膜塑形用硬性透气接触镜说明书编写指导原则 的通知》(食药监办械函〔2011〕143号)有关规定,现就有关事 项通知如下:
人员 2.技师
(1)具有中级以上技师职称; (2)参加省级卫生行政部门或省级卫生行政部门委托专业学术
团体组织的相关知识培训并经考核合格者。
符合验配基本条件技师必须在眼科医生的配合下完成验配OK 镜的工作。
《卫生部关于加强医疗机构验配角膜塑形镜管理的通知》(卫医发〔2001〕258号)
20
SUCCESS
10
相关法规
验配机构应具备条件(国药监2001)
验配人员应是中级职称以上的眼科医师或视光师;在从事验配 业务前,应按产品生产、经营单位的要求获得相应的授权。
验配场地总面积不得少于45平方米,设置有接待室、检查室、 验光室和配戴室等,并有良好的环境及卫生条件。
应配备相应验配设备,至少应包括:角膜曲率计、角膜地形图 仪(8mm以上直径测量范围)、非接触眼压计、角膜厚度测定 仪、电脑验光仪、综合验光仪、验光试片箱、裂隙灯显微镜、 远\近视力表、检眼镜、眼底镜、荧光素钠试纸、焦度计、镜 片投影仪(不低于7.5倍)、镜片弧度测定仪等。
重庆市食品药品监督管理局: 你局《关于角膜塑形镜经营企业开展角膜塑形镜验配的请
角膜塑型镜的配戴方法及护理说明
![角膜塑型镜的配戴方法及护理说明](https://img.taocdn.com/s3/m/625da6673d1ec5da50e2524de518964bcf84d2d8.png)
角膜塑型镜的配戴方法及护理说明角膜塑型镜的配戴方法及护理说明一、角膜塑形镜的戴镜方法镜的戴镜摘戴镜前准备:在摘戴镜前,须洗净双手,剪短指甲,使用的镜片也应彻底清洁。
具体的摘戴方法如下:1.戴镜法一将镜片内曲面向上置于右手食指尖端,在镜片凹面滴入一滴舒润液,配戴者双眼固视正前方,用左手食指拉开上眼睑,并固定在眉弓上,右手中指拉开下眼睑,将镜片轻轻放置于角膜中央,先松开下眼睑,再松开上眼睑,轻轻眨眼,对着镜子确保镜片戴在角膜上。
2.戴镜法二用戴镜侧手的食指和拇指打开双睑,手指的位置尽可能的靠近睑缘,镜片放置于另一只手的食指指尖上,将镜片轻轻戴在角膜中央,先松开下眼睑,再松开上眼睑,轻轻眨眼,对着镜子确保镜片戴在眼角膜上。
注:可在眼前放置一面镜子,戴镜时,应同时睁开双眼,让眼睛固视镜中一处,在戴镜时要控制眼球的转动,另外,要保证镜片在角膜上放置稳妥后,才可缓慢放开牵拉眼睑的手指,过早放开有可能使镜片偏移或脱落。
二、角膜塑形镜的摘镜方法1.摘镜法一可利用双手进行操作,用左手食指拉开上睑后再轻轻下压,使上睑缘顶住镜片上缘,用右手的食指拉开下睑,并利用下睑缘使镜片下缘脱离角膜,摘镜时,可在面部下方放一手帕或毛巾(避免使用绿色和蓝色的以防与与镜片混淆),以防镜片脱落后丢失。
2.摘镜法二睑裂大的人可试用单手进行操作,睁大眼睛,面部朝向正前方或略朝向外侧方,将戴镜同侧手的食指或中指,垂直放在外眦部,朝外上方牵拉双睑,此时睑裂变狭,上下睑缘轻压镜片的边缘部,随瞬目将镜片挤出,镜片脱出时用另一只手接住镜片。
事先应对镜进行练习,学习如何使用食指或中指,在牵拉眼睑时,如睑缘外翻,或镜片被覆盖于眼睑下方,镜片则不易被脱出,牵拉眼睑之前应睁大眼睛,充分暴露镜片的边缘。
3.摘镜法三利用前两种方法仍摘不下镜片时,可以使用吸棒取镜。
对着镜子,用左手的拇指和食指拉开双睑,右手持小吸棒,将吸棒吸附在镜片的边缘,偏颞侧,轻轻转动吸棒,即可把镜片取出。
角膜塑形镜说明书
![角膜塑形镜说明书](https://img.taocdn.com/s3/m/d00703cbb9f3f90f76c61b20.png)
附件:角膜塑形用硬性透气接触镜说明书编写指导原则角膜塑形用硬性透气接触镜(以下简称角膜塑形镜)说明书承载了产品预期用途、配戴步骤、警示、注意事项等重要信息,是指导配戴者正确操作、眼科专业人员准确理解和合理应用的重要技术性文件。
本指导原则基于国家食品药品监督管理局《医疗器械说明书、标签和包装标识管理规定》的有关要求,参考国外监管机构的经验及生产企业有关角膜塑形镜说明书编写方面的资料,对说明书的编写格式及各项内容进行了详细的说明。
其目的是为编写角膜塑形镜说明书进行原则性指导,同时,也为注册管理部门审核说明书提供技术参考。
由于产品特点、配戴环境和配戴者条件不同,产品说明书的内容可能不尽完全相同。
如果没有合理的理由和充分依据,各角膜塑形镜的说明书应当按照本指导原则的格式和内容,根据批准条件、产品特点及临床使用目的等情况进行编写。
说明书的字号比例应当与指导原则一致,无论采用彩色或单色印刷,色彩对比均需清晰一致,以便于相关人员获取准确的信息。
一、角膜塑形镜说明书格式角膜塑形镜说明书【注册号】【通用名称】【英文名称】【商品名称】【型号】【执行标准】【注册日期】【说明书批准及修改日期】【管理类别】【特别提示】【警示】【作用与用途】【适用范围】【适用人群】【禁忌症】【配戴时间】【加工方式、制成材料与颜色、结构等】【包装内部件】【护理用品】【配戴注意事项】【镜片配戴、摘取方法】【镜片的护理、存放】【护理液使用注意事项】【镜片盒使用注意事项】【不良事件】【储存条件、有效期】【生产企业】【国内代理人】(进口产品适用)【国内售后服务机构】(进口产品适用)二、各项内容撰写的说明【注册号】注明该产品的注册证书编号。
【通用名称】注明:角膜塑形用硬性透气接触镜(以下简称角膜塑形镜)。
【英文名称】注明:Rigid gas permeable contact lenses for orthokeratology。
【商品名称】商品名称的文字不得大于通用名称文字的两倍。
角膜塑形镜简介ppt课件
![角膜塑形镜简介ppt课件](https://img.taocdn.com/s3/m/81533d06daef5ef7bb0d3c30.png)
.
11
梦戴维角膜塑形术的有效性-近视控制
• 美国SMART研究课题(设计观察5年,现只完成两年)
–经过2年的观察,配戴角膜塑形镜的试验组(128)较 配戴软性角膜接触镜的对照组(83),近视加深明显 减缓。配戴角膜塑形镜的试验组右眼平均每年增长 9 度,左眼增长8度,而对照组右眼平均增长81度,左眼 73度。
• 西班牙MCOS研究课题
–经过12个月的观察,配戴角膜塑形镜的欧洲白人儿童 试验组(31),平均近视降低 193 度,而配戴单光框 架镜的欧洲白人儿童对照组(30)平均近视增加了46 度。
.
12
梦戴维角膜塑形术的有效性-近视控制
• 北京大学医学部 –经过3年的观察,戴角膜塑形镜的试验组每年近视度数 增长的平均值为8度,而配戴框架镜的对照组则为67度。
梦戴维角膜塑形术的有效性-近视控制
•多项独立研究表明:长期配戴角膜塑形镜
–眼轴增长平均减缓50%以上 –度数增长平均减缓60%以上
• 香港理工大学 –经过两年的观察,戴角膜塑形镜的实验组较戴框架镜 的对照组相比,眼轴每年增长平均值下降60%以上;
• 美国俄亥俄大学 –经过2年的观察,戴角膜塑形镜的试验组较戴普通RGP 和软性角膜接触镜的对照组相比,眼轴每年增长的平 均值下降 60% 以上。
荐
.
21
现代角膜塑形术较“OK镜”的进步
.
22
角膜塑形镜的历史
–第一代
• 1960年代;平坦RGP;PMMA
• 6个月减150度;角膜散光
–第二代
• 反转几何;三弧
• 单片减150度;3-6个月降300度
–第三代
• 反转几何;四弧;平压角膜
• 日戴;10-30天降400度
角膜塑形镜配戴护理实用手册
![角膜塑形镜配戴护理实用手册](https://img.taocdn.com/s3/m/571ac707fe00bed5b9f3f90f76c66137ee064f8f.png)
角膜塑形镜配戴护理实用手册一、配戴塑形镜必备护理用品:多功能护理液、舒润液、镜盒、吸棒、除蛋白液、除蛋白盒、洗瓶、凉白开水、镜子、毛巾、纸巾。
二、戴镜前的准备1、经检查确认,本人所取镜片完好无损;2、首次戴镜前需浸泡镜片6小时以上并充分清洗;3、修剪指甲,用流动的水和中性肥皂充分洗手;4、用凉白开水把镜片反复冲洗干净;5、在干净、平整的桌面上护理镜片或摘戴镜片,以免将镜片掉落在地上造成污染或找不到;6、戴镜前需确定好左右眼镜片,不要混淆戴错,镜片一般为蓝色—左眼,绿色——右眼。
三、每日戴镜之前1、确认镜片在护理液中浸泡6小时以上,取出后用凉白开将镜片冲洗干净,再用适量的多功能护理液揉搓、清洗镜片,最后再用凉白开水把镜片冲洗干净;2、戴镜前双手一定充分清洗,确保干净;勤剪指甲,不要留指甲;3、戴镜先右后左,注意分辨;4、将镜片内凹面向上放在右手食指指端;5、在镜片内表面滴入一滴舒润液,以防止戴镜后镜片内出现气泡;6、用左手中指按住上眼睑睫毛根部轻轻向上拉,用右手中指按住下眼睑睫毛根部向下拉;7、将镜片对准眼睛后准确放置于配戴眼角膜中央,镜片戴好后将撑开眼睑的手指缓缓移开,并轻轻眨眼数次;8、对着镜子检查镜片是否在角膜中央、镜片内表面是否有气泡,若镜片偏离角膜或者镜片内有气泡都需要摘下重新佩戴。
四、戴镜中1、不要用力揉眼睛,以免导致镜片的移位或损伤角膜表皮2、不要长时间停留在污浊空气化学烟气和风沙环境中3、如有灰尘掉入眼内,应该摘下镜片,眨眼,让灰尘排出,然后清洗镜片,重新戴镜;4、戴镜时勿使用任何眼药水,以免与发生化学反应;5、戴镜时出现眼红、异物感、流泪、畏光、疼痛等症状时,应立即摘下镜片重新清洗,然后再次配戴,如症状依旧应停止戴镜及时到验配中心复查。
五、摘镜1、用流动的水和中性肥皂充分洗手,并用多功能护理液将吸棒清洗干净。
2、确认镜片在角膜上,往眼内滴1-2滴舒润液,并轻轻眨眼两下让镜片充分活动。
欧洲科技公司 Placido Disk 矫正技术产品说明书
![欧洲科技公司 Placido Disk 矫正技术产品说明书](https://img.taocdn.com/s3/m/0d9a316bf68a6529647d27284b73f242336c3190.png)
Proven Placido Disk Technology• Patented Cone-of-Focus ™ Alignment System and Arc-Step Algorithm deliver sub-micron elevation accuracy 1• 22-ring Placido disk optimized to avoid ring crossover, which means reliable results for a wide range of patients• L ong, comfortable 70 mm working distance minimizesfocusing error found in “small cone” systemsSmartCapture ™ Image Analysis Helps Your Staff Get it Right the First Time• S martCapture analyzes 15 digital images per second during alignment and automatically selects the highest quality image• N ext-generation image processing provides more repeatable, reliable results, even in difficult cases • L ess dependence on operator technique means greater efficiency and fewer repeat examsWorkflow Flexibility with Review Software• D ynamic remote access to all your corneal topography exam data and patient education tools, such as corneal wavefront simulation• E quivalent analysis functionality as the ATLAS Model 90002• Compatible with ATLAS Models 993 and 9952Superior TopographyPerformance and EfficiencyThe ATLAS System has been proven to deliver the accuracy and workflow efficiency that your practice requires. The all-in-one system combines a suite of unique technologies that is simple for virtually any operator to use. The result is a new level of confidence in every exam and for every patient.SmartCapture makes image acquisition easyCornealSurfacePlacido RingsCone ofFocusTriangulation with the Cone-of-Focus, Placido rings, and corneal surface delivers superior accuracy1- Data on file2- Except for PathFinder II Corneal Analysis Software8- To one standard deviation on a properly calibrated 42.51 D (7.94 mm) test object.NOTE: All technical specifications are subject to change without notice.Windows is a registered trademark of Microsoft Corporation. Pentium is a registered trademark of Intel Corporation.Technical SpecificationsATLAS Model 9000Carl Zeiss Meditec AG Goeschwitzer Str. 51-5207745 Jena GermanyPhone: +49 36 41 22 03 33Fax: +49 36 41 22 01 /medCarl Zeiss Meditec, Inc.5160 Hacienda Drive Dublin, CA 94568USAToll-Free: +1 800 341 6968Phone: +1 925 557 4100Fax: +1 925 557 /med0297A T L .1587 R e v C S A P 000000-1502-420 P r i n t e d i n U n i t e d S t a t e s . C Z -I I /2017T h e c o n t e n t s o f t h e b r o c h u r e m a y d i f f e r f r o m t h e c u r r e n t s t a t u s o f a p p r o v a l o f t h e p r o d u c t o r s e r v i c e o f f e r i n g i n y o u r c o u n t r y . P l e a s e c o n t a c t o u r r e g i o n a l r e p r e s e n t a t i v e s f o r m o r e i n f o r m a t i o n . S u b j e c t t o c h a n g e s i n d e s i g n a n d s c o p e o f d e l i v e r y a n d d u e t o o n g o i n g t e c h n i c a l d e v e l o p m e n t . A T L A S , V i s a n t e o m n i , P a t h f i n d e r I I , M a s t e r f i t I I , C o n e -o f -F o c u s , S m a r t C a p t u r e a r e e i t h e r t r a d e m a r k s o r r e g i s t e r e d t r a d e m a r k s o f C a r l Z e i s s M e d i t e c , I n c . o r o t h e r c o m p a n i e s o f t h e Z E I S S G r o u p i n G e r m a n y a n d /o r o t h e r c o u n t r i e s .© C a r l Z e i s s M e d i t e c , I n c ., 2017. A l l r i g h t s r e s e r v e d .Working Distance 70 mmField of View 17 mm X 14.5 mmPlacido Rings 22 (18 superiorly, 22 inferiorly)Illumination Source Non-visible infrared (950 nm) LEDOptics Digital CMOS camera with 1280x1024 pixel resolutionCurvatureMeasurement Range AccuracyReproducibility 15 to 95 D (3.5 to 22.5 mm)± 0.05 D (± 0.01 mm)8± 0.10 D (± 0.02 mm)8HVID (white to white)Measurement Range Resolution10.0 to 14.0 mm 0.1 mmPupillometryAcquired Images Measurement Range ResolutionScotopic and photopic (700 nm)0.5 to 11.0 mm 0.1 mmViews• Axial Curvature • Tangential Curvature • Elevation (Best-Fit Sphere)• Irregularity (Best-Fit Ellipsoid)• Videokeratoscopic (Rings, Scotopic, Photopic)• Keratometry • Refractive Power • Mean Curvature • Corneal Wavefront • Image Simulation• Point Spread Function (PSF)• Modulation Transfer Function (MTF)Presentation Displays• Single View • Overview• OD/OS Comparison • Difference• Trend with Time, Trend Analysis • CustomOptional Software/Third Party Software• PathFinder™ II Corneal Analysis Software • MasterFit™ II Contact Lens Software • ATLAS™ Review Software• DICOM Gateway • Wave Contact Lens Software Computer• Microsoft ® Windows 7• 4th Generation Intel Processor• Internal storage: up to 35,000 exams • Gigabit Ethernet & USB 3.0• Integrated 12.1” color flat panel display Dimensions / Weight (Instrument only)• 52 L x 37 W x 50 H (cm)• 39 lbs. (17.7 kg)Electrical• 100-240V~: 50/60Hz, 2-1ASimply accurate for maximum productivitySuperior Performance Designed for How You Practice• C ompact, all-in-one system, now easier to use and more efficient• Improved repeatability and reliability• Compatible with your existing ATLAS data • Compatible with Visante®omni to generate posterior topography Elevate Your Practice with ATLASThe next-generation ATLAS System provides new tools and superior data acquisition and analysis to set your practice apart. From increasing patient satisfaction, to gaining greater clinical insight, to improving overall workflow, the ATLAS System can take your practice to new heights.Take your practice to the next levelWith more than 15 years experience in corneal topography, Carl Zeiss Meditec now offers the next generation of the ATLAS®Model 9000. The ATLAS System delivers the accuracy essential to today’s eye care practice, in a powerful and easy to use platform. With applications including contact lens fitting, abnormal cornea detection and management, and selection of aspheric IOLs, the new ATLAS System is the right choice for reliable real-world results, every time, from virtually any operator.3- M . Jeandervin and J. Barr, “Comparison of repeat videokeratography: repeatabilityand accuracy,” Optom. Vis. Sci. 75, 663–669 (1998)4- E valuating data acquisition and smoothing functions of currently available videokeratoscopes. J Cataract Refract Surg 22 (1996);22:421-4265- (accessed 10/01/09)6- /iol-main/keratorefractive.htm (accessed 10/01/09)Intuitive Analysis and ReportingNovel Applications for Cataract CareCorneal Wavefront Analysis is a valuable tool guiding you to the suitable technologies which will correct visual distortion. The ATLAS provides all the key topographical information needed to enhance IOL power calculation and IOL selection as well as set appropriate patient expectations.• E ducate patients about higher-order aberrations and simulate visual acuity with various pupil sizes • A ssess corneal refraction with image simulation and point spread function • O ptimize aspheric IOL selection with corneal spherical aberration, Z(4,0), based on Placido disk technology 3,4• E stablished IOL power formulas for myopic and hyperopic LASIK/PRK and RK 5,6• P erioperative astigmatism managementTopography MapDisplay as curvature, elevation, corneal wavefront, even image simulations. Landmarks such as corneal apex , pupil contour, and pupil center help explain the impact onvisual acuityColor ScaleCustomize colors and scales for detailed corneal assessmentsDataAutomatically display preferred parameters such as simulated keratometry, shape factor, eccentricity, and HVID (whiteto white)Cursor ValueObtain the exact value at any point on the mapAxial map reveals a displaced corneal apex and inferior steepening, which standard keratometry at 3mm would have missed.7- Data on filePathFinder II Corneal Analysis SoftwareAdvancing traditional topography. PathFinder ™ II Corneal Analysis Software is a comprehensive, easy tounderstand, and reliable anterior topographic screening module to assist with refractive surgery screening andto help identify abnormal corneal conditions.1.PathFinder II provides probabilities for 5 different corneal conditions by comparing topography exams to an extensive clinical database. Validation of PathFinder II with an independent data set demonstrated greater than 90% sensitivity, specificity, and accuracy in detecting normal versus abnormal corneas7.2.Color-coding of PathFinder II parameters quickly indicates which parameters are beyond normal limits and may contribute to specific classifications.3.In this example, traditional axial curvature does not highlight the nature of the cornea as compared to mean curvature.4.3-dimensional mean curvature analysis eliminates corneal astigmatism to reveal underlying local curvature irregularities. The size and location of corneal irregularities, especially in the periphery, are better highlighted.MasterFit II Contact Lens SoftwareDirect your fitting success. MasterFit™ II Contact Lens Software helps streamline fitting gas permeable(GP) lenses and guides you through challenging-to-fit patients. Simulated fluorescein patterns and tear filmthickness profiles promote effective lens design to minimize chair-time and improve patient satisfaction.• S imulate fluorescein patterns for custom and stock lenses, including spherical, toric, and aspheric designs • A utomatically design lenses to your preferences by customizing fitting options such as desired tear film clearance• I mprove trial lens fitting efficiency by adjusting lens parameters, such as peripheral curves, and simulating lens movement to compensate for lens-to-cornea relationship• E mail lens design and topography exam to your lab for efficient ordering and fulfillment。
科视欧几里德角膜塑形镜产品技术手册
![科视欧几里德角膜塑形镜产品技术手册](https://img.taocdn.com/s3/m/3bcc72838762caaedd33d44f.png)
科视产品技术手册内容表前言一、近视眼的相关知识二、角膜塑形镜基础知识三、角膜塑形镜的适应症与非适合人群四、角膜塑形镜的验配五、角膜塑形镜的订制六、患者培训七、复查与随访服务八、角膜塑形镜的配适不良及并发症处理九、角膜塑形镜矫治近视工作流程十、档案资料管理十一、结语十二、参考文献附件:1、矫治近视基本资料登记表2、复查记录3、角膜塑形镜配戴协议4、角膜塑形镜订单5、经营资质证件前言这是一本教育性手册,目的是概括介绍使用特别设计的角膜塑形镜矫治近视的情况,内容包括角膜塑形学的原理和戴镜流程。
学习验配角膜塑形镜的课程。
一、近视眼的相关知识近视已标志为影响人类最普遍的眼睛问题之一,并且仍作为全球性增长之中的问题,一个全球性现象是标志一个国家工业化及教育水平的提高。
近视发病率也在增加,发病率在不同的国家有所不同,从美国的低至25%到高至中国某些地区的90%,这使很多国家的政府和卫生组织很关注近视对市民影响。
具体如下表:1、何为近视眼近视眼就是远处的平行光线进入眼睛通过角膜等器官折射,焦点不能落在视网膜上,而是落在视网膜前方。
2、近视眼的分类:(1)按度数分:轻度:<-3.00D中度:-3.00~-6.00D高度:>-6.00D(2)按调节分:假性(调节性近视)真性混合性(部分假性近视存在)(3)按病因分:轴性屈光性(曲率性、屈折指数性)(4)按性质分:单纯性病理性3、近视眼的患病率:全球近视患者10亿,我国近视眼患者3亿。
亚洲为高发地区(中国、日本、韩国、新加坡)欧美较低,非洲最低。
与种族、性别、年龄、地区、环境等因素有关。
4、近视眼的发病原因:(1)遗传因素(2)环境因素传统调节理论——长期过度近距离用眼(应试教育、现代生活)其他因素:污染、营养、微量元素等5、近视眼的危害(1)视力障碍(2)视疲劳(3)外隐斜或外斜视(4)眼轴变长,飞蚊症(5)眼底改变,豹纹眼底、黄斑出血、视网膜脱离、巩膜葡萄肿等。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
科视欧几里德角膜塑形镜产品技术手册科视产品技术手册内容表前言一、近视眼的相关知识二、角膜塑形镜基础知识三、角膜塑形镜的适应症与非适合人群四、角膜塑形镜的验配五、角膜塑形镜的订制六、患者培训七、复查与随访服务八、角膜塑形镜的配适不良及并发症处理九、角膜塑形镜矫治近视工作流程十、档案资料管理十一、结语十二、参考文献附件:1、矫治近视基本资料登记表2、复查记录3、角膜塑形镜配戴协议4、角膜塑形镜订单5、经营资质证件前言这是一本教育性手册,目的是概括介绍使用特别设计的角膜塑形镜矫治近视的情况,内容包括角膜塑形学的原理和戴镜流程。
学习验配角膜塑形镜的课程。
一、近视眼的相关知识近视已标志为影响人类最普遍的眼睛问题之一,并且仍作为全球性增长之中的问题,一个全球性现象是标志一个国家工业化及教育水平的提高。
近视发病率也在增加,发病率在不同的国家有所不同,从美国的低至25%到高至中国某些地区的90%,这使很多国家的政府和卫生组织很关注近视对市民影响。
具体如下表:1、何为近视眼近视眼就是远处的平行光线进入眼睛通过角膜等器官折射,焦点不能落在视网膜上,而是落在视网膜前方。
2、近视眼的分类:(1)按度数分:轻度:<-3.00D中度:-3.00~-6.00D高度:>-6.00D(2)按调节分:假性(调节性近视)真性混合性(部分假性近视存在)(3)按病因分:轴性屈光性(曲率性、屈折指数性)(4)按性质分:单纯性病理性3、近视眼的患病率:全球近视患者10亿,我国近视眼患者3亿。
亚洲为高发地区(中国、日本、韩国、新加坡)欧美较低,非洲最低。
与种族、性别、年龄、地区、环境等因素有关。
4、近视眼的发病原因:(1)遗传因素(2)环境因素传统调节理论——长期过度近距离用眼(应试教育、现代生活)其他因素:污染、营养、微量元素等5、近视眼的危害(1)视力障碍(2)视疲劳(3)外隐斜或外斜视(4)眼轴变长,飞蚊症(5)眼底改变,豹纹眼底、黄斑出血、视网膜脱离、巩膜葡萄肿等。
严重影响生活、学习、工作、影响升学、参军、就业。
6、近视眼的矫治方法:世界卫生组织(WHO)将近视眼防治列入全球防盲计划。
这些关注引起对能控制近视或减低近视的多种系统进入我们的眼球。
(1)药物治疗:A、睫状肌麻痹药;B、降眼压药;C、中药(2)针灸或按摩、器械以上只是放松睫状肌,对假性近视有作用。
(3)眼镜矫正:框架眼镜:a、普通凹透镜;b、双光眼镜;c、三光眼镜;d、渐进多焦点眼镜只是普通的视力矫正,但是不能降低屈光度。
(4)手术治疗:准分子激光、晶体摘除、后巩膜加固术等(5)角膜接触镜(隐形眼镜):a、硬性角膜接触镜;b、软性角膜接触镜;c、硬性透气性角膜接触镜(RGP):(a)常规RGP (b)圆锥角膜RGP(c)术后矫正RGP (d)散光RGP(e)渐进多焦RGP (f)角膜塑形镜以上通过改变角膜形态来降低屈光度。
二、角膜塑形镜的基础知识1、角膜塑形术与角膜塑形镜角膜塑形术——将角膜表面曲率变平,使近视和散光减轻或消失,提高视力达到最佳视力效果的非手术方法。
角膜塑形镜——实行角膜塑形术所使用的一个工具即硬性透气性角膜接触镜。
与激光手术不同,与传统的OK镜不同。
2、角膜塑形镜的结构及设计原理设计特点:其内表面由基弧、反转弧、配适弧和边弧组成。
其中位于周边的配适弧力求与角膜旁中心区对齐,在泪液的充填作用下,镜片配适弧区与角膜面产生较为稳定的附着张力,位于中心区的基弧较角膜的曲率值更平,借助镜片的附着力对角膜光学区起到了压平的作用,从而使近视程度降低,总直径:10.6mm;光学区:6.0mm;反转弧宽度:0.5mm;适配弧宽度:1.2mm;边弧宽度:0.5mm;湿润角:36度;含水量:<1.0%;中心厚度:0.11~0.13mm;透氧系数:120×10-11(cm2/sec)[mLO2/(mL×mmHg)](允差±20%,@35℃);角膜弯曲度40.00D~45.00D(递变梯度0.25D 一档)3、角膜塑形镜的材料:该产品由BOSTON EQUALENS II(oprifoconA,一种氟化硅氧烷聚合物)制成。
高透氧性,湿润性良好,有足够的弹性模量、硬度和表面抗压特性,美国FDA批准。
4、角膜塑形镜矫治近视的作用机制(1)机械压力作用(2)泪液流动作用(3)眼睑按摩作用(4)阻止眼轴增长5、角膜塑形镜矫治速度:因人而异,平均2小时降低1.00D以上;一个晚上通常可降200—300度左右。
3—7天达到理想状态。
6、角膜塑形镜的作用及优点:(1)矫正近视:短期内视力可提高,近视度数降低明显,在一定时间内为中低度近视患者提供方便、快捷的良好裸眼视力。
(2)夜戴。
白天可维持良好视力。
(3)不用手术,相对安全。
(4)有控制青少年近视发展、加深的作用。
(5)为不适合、不愿意做激光手术者或不愿意戴框架眼镜的近视患者提供了一种有效的矫治方法。
三、角膜塑形镜的适应证与非适合人群1、适应证:年龄:6岁到40岁近视:-0.50D到-8.00D近视散光:散光度≤1/2近视度,其中逆律散光(轴位90°±30°)≤-1.50D职业需要:学生、运动员、司机等特殊岗位者。
美观:可以避免眼镜对眼部的遮盖和对面部的修改作用。
2、非适合人群:眼部禁忌症包括各种原因导致的干眼症;慢性泪囊炎;眼睑闭合不全;麻痹性斜视;眼球震颤;严重慢性角膜结膜炎;圆锥角膜;慢性色素膜炎;弱视;晶状体混浊及慢性青光眼。
全身禁忌症包括急慢性鼻窦炎;严重糖尿病;正在使用对角膜塑形有影响的药物;类风湿性关节炎等胶原性疾病及精神病患者等。
四、角膜塑形镜的验配1. 初步检查:眼科医师或眼视光师通过一系列仪器对配戴眼进行初步检查,确定除近视外,无其他影响戴镜的眼部疾病方可进入角膜塑形术以下的验配程序。
2. 咨询谈话:当用户自愿选择接受采用角膜塑形术进行近视矫正时,须仔细向科视的专业人员咨询了解整个矫正过程及注意事项,仔细阅读和签署《科视系统角膜塑形术责任书》,并办理缴费手续。
3. 专项检查:通过角膜曲率计、角膜地形图仪、自动验光仪、非接触式自动眼压计、A型超声波、综合验光仪、裂隙灯显微镜、眼底镜等专项检查采集临床参数作为订制加工镜片的依据。
4. 配前预测:根据对配戴眼检测所得到的技术参数(主要有眼屈光测定值、角膜曲率半径、角膜偏心度,散光及其类型、角膜地形图形态、眼球后前径轴长、角膜厚度和眼压等)预测最低矫正指标。
五、角膜塑形镜的配制1. 订制镜片:经专项检查确定为配戴眼符合适应范围,即将检测参数传输美国,经电脑处理加工订制适合于配戴眼形态的角膜塑形镜。
2. 品质控制:镜片自美国寄来以后,科视系统首先核对镜片的姓名编号准确无误,然后采用各种分析仪器检测镜片质量(包括:镜片曲率、直径、焦度、光洁度等项参数指标)后,方交由用户签收。
六、患者培训1、配戴须知每次操作镜片之前须认真洗手,保持指甲短而修剪完整。
在干净、平整的桌面上护理或戴摘镜片,以免脱落在地上或遗失。
戴镜最佳时间为7-8小时,最少不能少于6小时,最长不能超过10小时。
每次配镜之前仔细观察镜片有无破损或严重沉淀物。
若镜片已破损则不能配戴。
若镜片有沉淀物,则须处理清洁后再戴。
矫正初期会产生轻度事物叠影现象,一般1-3月后则逐渐减轻或消失。
矫正过程中的前3个月视力会有轻度波动,3个月以后视力则趋于稳定。
戴镜之前和摘镜之后检查双眼,如有眼镜发红,分泌物增多,则不要勉强戴镜,可停戴1-2天,如症状加重则需到本地的科视连锁验配机构或就进的医院眼科进行检查。
戴上镜片后须体会是否清晰、舒适,如有严重的异物感、刺激感、瘙痒感、烧灼感和视物模糊等症状则应及时摘下镜片寻找原因。
2、戴镜和摘镜方法戴镜技术用流动的水和中性肥皂充分洗手。
用适量护理液冲洗镜片。
再用纯净水冲洗镜片将镜片内曲面向上托在右手食指指端上。
在镜片内曲面注满润眼液,以防止戴镜后发生片下气泡。
面向下俯,注视桌面上的平面镜。
切记左眼绿色,右眼蓝色。
用左手食指或中指按住配戴眼上眼皮边缘,将眼皮向上充分撑开,并按在眉弓上加以固定。
用右手中指按住配戴眼下眼皮边缘,将下眼皮向下充分撑开。
将镜片快速轻柔地放置在配戴眼暴露的角膜(黑眼球)中央部。
轻轻眨眼数次,用纸巾拭去溢出睑裂的润眼液。
按上述方法先右后左依次配戴。
3、摘镜技术用流动的水和中性肥皂充分洗手。
在配戴眼内滴1到2滴润眼液。
如配戴时的方法,充分撑开配戴眼的眼皮。
用右手拇指和食指将吸棒的盘端轻轻挤按在镜片中央部,摘下镜片。
摘镜注意事项若镜片附着过紧,取镜的阻力过大,则可再次在眼内滴1~2滴润眼液,将吸棒盘端挤按到镜片中央。
摘下镜片后,应小心地将镜片轻轻从吸棒的盘端上滑下,不要用力捏镜片,以免损坏镜片。
4、戴镜注意事项撑开眼睑的手指若着力点远离眼皮边缘,则因配戴者能自由眨眼,可导致戴镜时将镜片挤出眼外。
在戴镜过程中,若镜片被挤出睑裂或掉落在桌面上,须充分冲洗后再戴。
在戴镜时,尽量减少泪液或护理液粘到配戴眼的眼皮上,以避免撑开眼睑的手指滑落,使戴镜失败。
若戴镜后,发现有片下气泡,则务必取下重新配戴。
配戴者戴镜后若有异物感,可向下注视或在眼内滴1-2滴润眼液,可望减轻症状。
戴镜期间忽然感到眼疼、流泪、畏光和视力下降,应立即摘下镜片到当地科视连锁验配机构进行复查。
配戴者若在矫正期内需要验光,或在矫正期结束后仍有一定程度的近视,需要根据验光结果配戴框架镜时,请在本地的科视连锁验配机构进行验光,因为若对于角膜塑形术没有足够的经验则可导致错误的验光结果。
请持之以恒的依照规定的程序清洁、冲洗和消毒储存镜片。
注意每三个月要换新的镜片盒和硅胶吸棒。
必须使用科视要求的硬性角膜接触镜护理液护理镜片,避免使用自来水、冷开水、无防腐剂的生理盐水或软性镜片护理液护理镜片,否则可能导致眼睛发炎,并影响镜片的使用寿命。
禁用洗涤净、肥皂、酒精等其他代用品清洁镜片。
镜片长期不使用,夏季每三天更换一次护理液,冬天每一周更换一次护理液。
七、复查及随访服务--填写复查记录1、戴镜后首次复查:第1天上午取下镜片之后,中午之前2、检查内容:自觉症状、视力、屈光度、角膜曲率等的变化,角膜地形图等检查。
如无问题可按以下计划,复查时认真作好复查记录。
3、复查计划:1、矫正期:指戴镜后3个月以内。
第1天、第1周、第2周、第1个月、第2个月、第3个月。
2、维持期:指戴镜3个月以后,每3个月复查一次。
八、日常工作中常见问题及处理方法1、镜片偏位原因的分析和相应处理原因:(1)人为因素。
如果睡觉时一直保持一个卧位,或者频繁转动眼睛,会导致镜片偏位,引起矫正效果下降。
因此需要告知客户在戴镜睡觉时不要局限于一个姿势,特别是侧卧,另外告知客户不要趴着睡,这样会减小压力,影响效果,所以戴镜睡觉时可以仰卧,左右侧卧,轮换卧位姿势。