NB-IOT无线光电式接近开关传感器产品说明书

合集下载

光电传感器产品参数说明书

光电传感器产品参数说明书

Photoelectric Sensors2.144BMOA Miniature Remote Amplifier SensorsNeed the precision of a laserphotoelectric sensor, but have no room to mount something that big? Ultra miniaturesensing heads down to 2 mmcan fit into applications wheremost sensors won’t. The BMOA component systems use an amplifier to power and control the signals from the sensing head, making it a unique alternative to typical fiber optic solutions. The BMOA component systems offer maximum flexibility with high flex cable versions for moving applications likerobotic arms. The systems can detect targets as small as 0.05 mm. The BMOAamplifiers make set-up and operation easy, using a simpledynamic teach function, or amanual push-button adjustment mode. Available in economical discrete or advanced analog outputversions to solve difficult applications.Features– Smallest sensing head in the industry– Laser-like precision to detect targets as small as 0.05 mm – High speed switching up to 5 kHz– 50 ms pulse stretching delay – Simple pushbuttonadjustment of dynamic teach function– Stability and Output Function LEDs– Discrete output versions PNP and NPN– Analog Output versions 0…10 Vdc and 4…20 mA – Din-rail or panel mountable Applications– Thread detection – Small part profiling – Robotic end-effectors– Semiconductor component detection– High performance alternative to fiber opticsBMOAMiniature Remote Amplifier SensorsBMO A01... amplifiers only.C o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o m2.145t p76o amplifier connectoramplifier connectoramplifier connectorC o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mPhotoelectric Sensors2.146High SpeedBMO A01-I-PU-C-02BMO A01-I-NU-C-02SeriesDiscrete Output PNP Normally-open NPNNormally-open Analog Output 0...10 Vdc 4...20 mASupply VoltageVoltage Drop U d at I e Output Current (digital)Analog Output Type (Voltage)Analog Output Type (Current)Analog Output Load (voltage) min load Analog Output Load (current) Max Load Current Consumption I o (no load)Protections Response TimeSwitching FrequencyPulsed/Non-Pulsed Light Source Output FunctionOperating Temperature Range Degree of Protection per IEC 60529Sensitivity/Range Adjustment Power/Stability Indication Alarm Indication Output LEDHousing MaterialWeightConnection (to control system)10…30 Vdc< 2 V 100 mA 45 mAShort Circuit, Reverse Polarity100 µs 5 KHz Non-PulsedLight/Dark Selectable -10° C to +55° CIP 65Teach-in and ManualGreen LED Yellow LED ABS 55 g2 m PVC Cable ,3 x 26 AWGq w e rBMOAMiniature Remote Amplifier SensorsSensitivity settingAUT – the amplifier will determine the best setting for the application.MAN – this allows you to fine-tune the settings or manually adjust the sensor for difficult applications.Wiring DiagramsOutput GNDOutput GNDrC o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mFiber Optics/photoelectricObject Resolution for Diffuse Sensors42-2-4-6-8Y(mm)055M, 06TM & 66RMYMeasuring Arrangement:900a standard resolution amplifier.04SM, 05TM & 66RMthe beam at certain ranges.Sensing Distance for Diffuse Sensors0.8% 1.6% 3.1% 6.3% 12.5% 25% 50% 100%Absolute Mode (ABS)This mode offers the maximum accuracy for allapplications. The amplifier will offer 8 stages ofCourtesyofCMA/Flodyne/Hydradyne▪MotionControl▪Hydraulic▪Pneumatic▪Electrical▪Mechanical▪(8)426-548▪www.cmafh.co m。

Turck NI5-M12-Y1X-H1141 型号的非沉 flush 感应式无线感应传感器说明书

Turck NI5-M12-Y1X-H1141 型号的非沉 flush 感应式无线感应传感器说明书

T 10:09:29+01:00Type designation NI5-M12-Y1X-H1141Ident no.40103Rated switching distance Sn 5 mm Mounting conditionsNon-flushSecured operating distance ð (0,81 x Sn) mmCorrection factors St37 = 1; Al = 0.3; stainless steel = 0.7; Ms = 0.4Repeat accuracy ð 2 % of full scale Temperature drift ð ± 10 %Hysteresis1…10 %Ambient temperature-25…+70 °C Output function 2-wire, NAMUR Switching frequency 2 kHzVoltageNom. 8.2 VDC Non-actuated current consumption ï 2.1 mA Actuated current consumption ð 1.2 mAApproval acc. toKEMA 02 ATEX 1090XDesign Threaded barrel,M12 × 1Dimensions52 mmHousing material Metal, CuZn, Chrome-plated Active area materialPlastic, PA12-GF30Max. tightening torque housing nut 10 NmElectrical connection Connectors, M12 × 1Vibration resistance 55 Hz (1 mm)Shock resistance 30 g (11 ms)Protection class IP67MTTF6198 years acc. to SN 29500 (Ed. 99) 40 °C Packaging unit 1Switching stateLED, Yellow■ATEX category II 1 G, Ex zone 0■ATEX category II 1 D, Ex zone 20■SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0■SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1 with re-dundant configuration HFT1■M12 × 1 threaded barrel ■Chrome-plated brass ■DC 2-wire, nom. 8.2 VDC■Output acc. to DIN EN 60947-5-6 (NA-MUR)■M12 x 1 male connectorWiring DiagramFunctional principleInductive sensors detect metal objects con-tactless and wear-free. For this, they use a high-frequency electromagnetic AC field that interacts with the target. Inductive sensors generate this field via an RLC circuit with a ferrite coil.T 10:09:29+01:00Distance D 3 x B Distance W 3 x Sn Distance T 3 x B Distance S 1.5 x B Distance G 6 x Sn Distance N2 x Sn Diameter active area BØ 12 mmT 10:09:29+01:00AccessoriesType codeIdent no.DescriptionIMC-DI-22EX-PNO/24VDC75600032-channel isolating switching amplifier with M12x1 males,for peripheral use, IP67, zones 2/22, input circuits II(1) Ex ia,PNP transistor output NOIMX12-DI01-2S-2T-0/24VDC7580020Isolating switching amplifier, 2-channel; SIL2 acc. to IEC 61508; Ex-proof version; 2 transistor outputs; input Namur signal; ON/OFF switchable monitoring of wire-break and short-circuit; toggle between NO/NC mode; signal doubling;removable screw terminals; 12.5 mm wide; 24 VDC power supplyQM-126945101Quick-mount bracket with dead-stop; material: Chrome-plat-ed brass Male thread M16 x 1. Note: The switching distance of proximity switches can be reduced by the use of quick-mount brackets.BST-12B 6947212Fixing clamp for threaded barrel devices, with dead-stop; ma-terial: PA6MW-126945003Mounting bracket for threaded barrel devices; material: Stain-less steel A2 1.4301 (AISI 304)T 10:09:29+01:00AccessoriesType code Ident no.DescriptionBSS-126901321Mounting bracket for smooth and threaded barrel devices;material: PolypropyleneT 10:09:29+01:00Operating manual Intended useThis device fulfills the directive 2014/34/EC and is suited for use in explosion hazardous areas according to EN 60079-0:2012 + A11 and EN 60079-11:2012.Further it is suited for use in safety-related systems, including SIL2 as per IEC 61508.In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives.For use in explosion hazardous areas conform to classificationII 1 G and II 1 D (Group II, Category 1 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmo-spheres).Marking (see device or technical data sheet)É II 1 G and Ex ia IIC T6 Ga acc. to EN60079-0 and -26 and É II 1 D Ex ia IIIC T115°C Da acc. to EN60079-0Local admissible ambient temperature -25…+70 °CInstallation/CommissioningThese devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas.Please verify that the classification and the marking on the device comply with the actual application conditions.This device is only suited for connection to approved Exi circuits according to EN 60079-0 and EN 60079-11. Please observe the maximum ad-missible electrical values.After connection to other circuits the sensor may no longer be used in Exi installations. When interconnected to (associated) electrical equip-ment, it is required to perform the "Proof of intrinsic safety" (EN60079-14).Attention! When used in safety systems, all content of the security manual must be observed.Installation and mounting instructionsAvoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device.If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields.The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet.Service/MaintenanceRepairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed.。

无线传感器安装说明书

无线传感器安装说明书
8-1 MODULATION FREQUENCY CHANGEOVER FUNCTION ........ 13 8-2 TRANSMISSION POWER SELECTION FUNCTION.......... 13 8-3 ALARM MEMORY DISPLAY FUNCTION ........................... 14 8-4 SOUND CHECK FUNCTION .............................................. 14 8-5 RESPONSE TIME ADJUSTMENT FUNCTION .................. 14 8-6 UPPER/LOWER CHANGEOVER FUNCTION.................... 14 8-7 AUTO GAIN LOCK FUNCTION .......................................... 15 8-8 PROGRAMMABLE AGC FUNCTION ................................. 15 8-9 LIGHT SENSITIVITY SIGNAL FUNCTION ......................... 15 8-10 EXTERNAL ENVIRONMENT DIAGNOSTIC FUNCTION ....... 15 8-11 ALIGNMENT WIRELESS CHECKER CONNECTION
3-2 MOUNTING HEIGHT ............................................................ 4 3-3 OPTICAL AXIS ADJUSTMENT RANGE ............................... 5 3-4 EXAMPLE OF PRACTICAL APPLICATION.......................... 5 4 INSTALLATION METHOD 4-1 WALL INSTALLATION METHOD.......................................... 6 4-2 POLE INSTALLATION METHOD.......................................... 7 5 WIRING METHOD 5-1 POSITION AND RATING OF TERMINALS........................... 8 5-2 WIRING DISTANCE BETWEEN SENSOR AND

接近开关使用指南

接近开关使用指南

接近开关使用指南一:规格参数品牌RIKO/瑞科反应频率25HZ CE加工定制【型号】:SN04-N (NPN NO常开)SN04-P (PNP NO常开)【外形】:方形18*18*36mm【线长】:1.5M【检测距离】:4mm【响应时间】:2ms to 50ms【迟滞距离】:≤10%检测距离【检测物体】:金属(铜、铁、铝、金等)【输出电压】:10-30VDC【输出电流】:300MA【外壳材料】:塑料ABS二:原理及相关使用1.额定电压:10~30V2.需搭配福誉模组使用3.使用原理:本接近开关为电感式接近开关,用来检测金属物体。

当接近开关前端检测到金属物体时,接近开关触发,灯亮且信号线释放反向电平。

4.关于NPN和PNP型的接近开关的使用区别:NPN型:有效(触发)时信号线释放低电平PNP型:有效(触发)时信号线释放高电平因此在搭配我们的控制器,即无论是单轴控制器还是三轴控制器(都是低电平有效),都请配NPN型的接近开关。

5.接线:黑色:信号线棕色:+24V蓝色: 0V注:具体接线请根据实际情况,搭配我们的控制器请按照相关控制器使用指南。

三:搭配控制器的使用说明1.搭配我们的单轴DKC控制器使用时:按照DKC使用指南正确将两个接近开关接入并安装到模组上的两个不同的位置时,此时接近开关仅起到限制行程的作用。

因此DKC-1B控制器控制的每根轴上两端都应该有一个接近开关,用来进行往复运动时起到限位的作用。

使用注意:由于电感式接近开关的感应距离短,安装限位器时请尽量缩短与检测金属物体(滑台或拖板)的距离,当且仅当接近开关检测到金属物体时,接近开关触发,灯亮,信号线释放反向电平。

2.搭配我们的4030三轴控制器使用时:按照AMC4030使用指南正确将接近开关接入并安装到模组上的任意位置时,此时接近开关仅起到提供原点位置的作用。

因此AMC4030控制器控制的每根方向轴上都应该有一个接近开关,用来提供原点位置及给软件获取相对位置的作用。

深圳市祥为测控技术有限公司 NB-IOT温湿度传感器XW-TH201N说明书

深圳市祥为测控技术有限公司 NB-IOT温湿度传感器XW-TH201N说明书

深圳市祥为测控技术有限公司文档版本:v1.0 产品使用说明书N B-I O T温湿度传感器X W-T H201N版本号:v1.0修订人:莫战审核:罗意日期:2020-7-14适用范围本产品适用于数据中心、电力、生物制药、石油化工、工业现场等各类需要温湿度监控测量的场所。

产品简介XW-TH201N温湿度传感器采用最新技术的半导体敏感器件设计方案和最新的NBIOT无线传输技术,用于测量室内环境的温度、湿度的一体化智能监控模块。

具有无线传输,远程监控、精度高、功耗低、外形美观、安装方便等特点。

内置大容量电池,无需外加电源,使用寿命可达三年以上。

技术参数基本特点产品尺寸92.9*72.13*39.13无线性能上传频率12小时1次(默认),可修改(上传时间间隔越长,使用寿命越长)工作频段800MHz/900MHz接收灵敏度-137dB发射功率23dB数据传输速率15.625kBPS-54Kbps测试范围温度测量-20℃~70℃湿度测量0~100%RH温度精度误差<±0.3℃,在25℃时测试。

湿度精度误差<±3%RH,在25℃时测试。

电源要求供电电压 3.6V/3500mAH内置电池订购须知型号XW-TH201N说明无线传输,远程监控;实时监测温湿度数据无线传输通信技术NB-IOT 通信协议HTTP1.1功率待机电流<3uA数据采集<5mA上报峰值<230mAESD(静电)接触放电±8KV,空气放电±12KV其他电池寿命3年以上⏹采用最新的NBIOT技术,实现无线传输,远程监控。

⏹0.01读取精度,外形美观,操作简便。

⏹待机电流小于3uA⏹内置大容量电池,使用寿命可达三年以上。

⏹空气循环流通外壳,抗电磁干扰设计,独特风道设计,防止电路温升影响传感器精度。

⏹可通过USB接口设置相应参数。

⏹测量准确,精度高,数据传输稳定。

⏹模块化结构,安装、维护方便。

接近开关传感器PPT课件

接近开关传感器PPT课件
近传感器已经在很多自动化行业找到了应用方向。在日常 运行时接近开关的主要应用问题上,有36%的受访工程 师提到了连续与批处理。在所有的应用当中,离散制造占 了29%,连续处理只占16.7%,公用工程应用占7.2%。 只有4.3%的受访工程师选择了批处理。其他的应用方向 占6.5%
广泛丰富的应用类型
3. 霍尔接近开关 霍尔元件是一种磁敏元件。利用霍尔元件做成的开关,叫做霍尔开关。
当磁性物件移近霍尔开关时,开关检测面上的霍尔元件因产生霍尔效应 而使开关内部电路状态发生变化,由此识别附近有磁性物体存在,进而 控制开关的通或断。这种接近开关的检测对象必须是磁性物体。 4. 光电式接近开关
利用光电效应做成的开关叫光电开关。将发光器件与光电器件按一定 方向装在同一个检测头内。当有反光面(被检测物体)接近时,光电器 件接收到反射光后便在信号输出,由此便可“感知”有物体接近。 5. 热释电式接近开关 用能感知温度变化的元件做成的开关叫热释电式接近开关。这种开关是 将热释电器件安装在开关的检测面上,当有与环境温度不同的物体接近 时,热释电器件的输出便变化,由此便可检测出有物体接近。 6. 其它型式的接近开关
常见 型号
常用电容式接近开关规格型号及具体参数
(浙江·洞头光电开关厂提供)
附:各种型号尺寸
西普公司的相关产品
以CJS12糸列为例
具体参数
更多信息详见西普
其他接近开关
一. 光电开关
反 射 板 型
二. 霍 尔 开 关
三.磁性开关
更多信息 详见:
西普
接近开关传感器应用方向
各种型号尺寸35现在按形状来分类举西普公司的产品为例3637通用型糸列3839再举其中j5糸列为例参数如下4041更多信息详见西普42它的测量头通常是构成电容器的一个极板而另一个极板是物体的本身当物体移向接近开关时物体和接近开关的介电常数发生变化使得和测量头相连的电路状态也随之发生变化由此便可控制开关的接通和关断

拓展能源 非接触型2线温度传感器系列说明书

拓展能源 非接触型2线温度传感器系列说明书

U Linear 4 to 20 mA Output U Simple 2-Wire InstallationU 10 to 40 Vdc Power Operation UResponse Time Adjustable from 0.2 to 5.0 SecondsU Interfaces with Panel Meters,Controllers, Recorders, Dataloggers, and ComputersRugged, Industrial, Infrared Temperature Transmitterswith 4 to 20 mA OutputOS1700Series sensor with integral electronics.OS1800 Series sensor with integral electronics/display.Shown smaller than actual size.OS1600 Series OEM stylesensor and remote electronics.U Wide TemperatureRange of-45 to 2500°C (-50 to 4500°F)U 3 Models toChoose FromU 6 Infrared SpectralResponsesThe OS1600, OS1700, and OS1800 Series are a complete family of non-contact infrared 2-wire temperature transmitters, with temperature ranges from -45 to 2500°C (-50 to 4500°F). This familyprovides the ultimate in performance and versatility at an economical price, with 2-wire simplicity, a choice of 6 infrared spectral responses, and a broad range of temperature capabilities. The linear 4 to 20 mA outputOS1600/1700/1800SeriesStandard 4 to 20 mA output can be used with data acquisitionequipment for computer-based monitoring and control.signal allows the sensor to be interfaced with a variety of remote devices: indicators, controllers, recorders, and/or computers, etc.For fine tuning, the sensors have an adjustable response time of 0.2 to 5.0 seconds, an emissivity adjustment of 0.1 to 0.99, and an adjustable peak hold option. Accessories include an air purge collar to protect the lens and a water cooling/air purge unit for high ambient exposure temperatures up to 120°C (250°F). Completely self-contained in a rugged, compact NEMA 4 (IP66) enclosure, the OS1800 Series sensor offers the additional convenience of a built-in digital display for local on-site readings. The OS1800 Series is supplied complete with OS1800-SB swivel mounting bracket for aligning the sensor (on the back of the unit) to “look” at the surface being measured.The OS1700 Series is completely self-containedin a rugged, compact housing. Combining the electronics with the infrared sensor, the OS1700 is ideal for OEM and multi-unit installations. MountingRear view showing sensor.accessories for the OS1700 are optional and must be ordered separately (see accessory ordering matrix on the following pages).The OS1600 Series rugged sensor combines a miniature sensing head with remote electronics for applications in restricted areas. It is designed for OEM and multi-unit applications where cost and space are limiting factors. The OS1600 Series comes completewith infrared sensing head, 3 m (10') of interconnecting cable, electronics board, OS1600-2LN mounting lock nuts, OS1600-MB mounting base, and complete operator’s manual.OS1811-112-S shown actual size.R u g g e d!i n d u s t R ia l!** Specify focal option from focal option table.Ordering Example: OS1811-16-C, combined IR sensor, electronics, NEMA 4 housing and integral display, plus OS1800-AP, air purge. OCW-3, OMEGACARE SM extends standard 1-year warranty to a total of 4 years.OS1700 units arecompatible with current input process indicators.DP25-E meter (shown) sold separately. See OMEGACARE SM extended warrantyprogram is available for models shown on this page. Ask your sales representative for full details when placing an order. OMEGACARE SM covers parts, labor and equivalent loaners.SpecificationsAccuracy: ±0.75% FS Repeatability: ±0.5% rdgWorking Distance: 6” to infinity Response Time: Adjustable from0.2 to 5.0 sec (to reach 99% of final value) Emissivity: OS1800 is digitally adjustable from 0.1 to 0.99; OS1600/ OS1700 are adjustable by analog trim pot from 0.1 to 0.99Output: Linear 4 to 20 mA DC, isolated Input Power: 10 to 40 VdcAmbient Temperature Range:OS1600: 0 to 75°C (32 to 165°F) OS1700, OS1800: 0 to 60°C(32 to 140°F)Enclosure: OS1800; NEMA 4 (IP65) Dimensions:OS1600: Sensor 3.8 x 9.5 cm(1.5 x 3.75"), circuit board10.2 x 11.4 cm (4 x 4.5")OS1700: 10.8 x 7.0 cm (4.5 x 2.75") OS1800: 11.5 x 11.5 x 8.9 cm (4.5 x 4.5 x 3.5")Weight:OS1600: Sensor 333 g (11.75 oz), circuit board 78 g (2.75 oz)OS1700: 0.55 kg (1 lb 3 oz)OS1800: 1.7 kg (3.75 lb)in OS1700 and OS1800 Series.Focal Options(see optical diagrams/Accessories for OS1600,DP41-E processindicator soldseparately.See OS1600, OS1700 and OS1800 Series.Focal Options Available for OS1600, OS1700, and OS1800 SeriesStandard 4 to 20 mA output can be usedwith data acquisition equipment forcomputer-based monitoring and control.OS1700 features screw terminalconnectors for fast, easy hook-up.。

接近开关说明书

接近开关说明书

Vs:power supply 电源P:Bleeder resister,number of W 分流电阻功率Io:Min.operating current of proximity switch接近开关的最小动作电流Ioff:Return current of load 负载的恢复电流110VAC 50/60HZ,bleeder resister over 20K,Min.3W220VAC 50/60HZ,bleeder resister over 39K,Min.5WBe sure to follow the safety precautions below for adder safety以下项目在安全确保方面非常重要,请务必遵守。

.1.Do not use the sensor under the explosive or flammable gas environment.请不要在具有可燃性、爆炸性气体的环境下使用。

2.Never disassemble, repair or tamper the product.请勿拆卸、修理、改造本产品。

3.Keep the supply voltage within the specified area.电源电压必须在额定值内。

e the load under the specified area.请使用额定值以下的负荷。

Caution for using正确使用方法1.Do not use the product under the following conditions.请不要在以下的环境中使用。

(1)In the place of the direct sunlight.日光直射场所。

(2)In the place where humidity is high and condensation may occur.湿度高或易结露场所。

(3)In the place of the corrosive gas exists.含腐蚀性气体场所。

光电传感器说明书)

光电传感器说明书)

规格(注1):(注2):(注3):(注4):如果串联连接5~8个放大器为50mA ,如果串联连接9~16个放大器为25mA 。

连接器型LS-401(P )没有装备外部输入。

H-SP 模式改变为其他模式后,当使用防干扰功能、收集的数据库载入/保存功能或复制功能时,再打开电源。

连接器型LS-401(P )不附带电缆。

请按下述使用另售单触电缆 。

母电缆(4芯):CN-74-C1(电缆长1m ),CN-74-C2(电缆长2m ),CN-74-C5(电缆长5m )子电缆(2芯):CN-72-C1(电缆长1m ),CN-72-C2(电缆长2m ),CN-72-C5(电缆长5m )注意事项●●●●●●●●●●●●●●●●请确认在电源关闭状态下进行接线和增设作业。

请确认电源电压在额定范围内变化。

请注意如果使用的电压超出额定范围,或直接连接AC电源,传感器可能烧坏或损坏。

如果在该传感器附近使用产生噪音的设备(开关调节器,转换发动机等),请将设备机架接地端子(F.G.)接地。

由于超长距离(U-LG)模式的灵敏度比其他模式更高,所以更容易受外部噪音影响。

确保使用前检查周围环境。

如果电源是市场上零售的开关调节器,请务必安装电源的机架接地端子(F.G.)接地。

电源接通后短时间(约0.5秒)内,请勿使用。

请注意短路或负荷的错误接线可能烧坏或损坏传感器。

请勿将电线与高压线或电源线一起或在同一管内拉线,这可能会由于感应而引起故障。

连接器型LS-401(P )必须使用另售单触电缆。

0.3mm 2以上电缆可延长至100m。

但为减少噪音,使接线尽可能短。

请勿用在屋外。

避免灰尘、污垢和水蒸气。

请勿将传感器与水、油、油脂或有机溶液,如稀释剂等直接接触。

此传感器不可在有易燃易爆气体的环境下使用。

不可拆卸或改装传感器。

MC-LS400 No.8137-00非常感谢您购买SUNX产品。

请仔细、完整阅读此使用说明书以便正确、合理地使用此产品。

请务必妥善保管此说明书。

NB-IOT微功耗无线温度传感器产品说明书

NB-IOT微功耗无线温度传感器产品说明书

【上海数采物联网科技有限公司】微功耗电池供电无线温度传感器产品说明书版本:V 1.1目录1 产品概述 (3)2 服务理念 (3)3 产品特性 (4)3.1温度采集特性 (4)3.2电气特性 (4)3.3通信特性 (4)3.4结构特性 (4)3.5工作环境 (4)4 产品核心优势 (5)5 平台对接 (5)5.1平台数据示例 (5)5.2参数说明 (5)6 注意事项 (6)1产品概述SC-LP-NTCNB微功耗无线温度传感器是上海数采物联网科技有限公司推出的一款针对工业领域的无线测温产品。

本产品将热电偶、热电阻信号变换成输入电信号或被测温度并以NB-IOT或4G等方式定时上报数据。

将作为新一代测温数据上云产品可广泛应用于冶金、石油化工、电力、轻工、纺织、食品、国防以及科研等工业部门。

本产品可以设定时间间隔进行温度数据采集,并将数据上传到服务器。

终端内置长寿命锂电池,支持采NB-IOT/LoRa/4G通信方式,能够克服现场特殊环境导致的无线通信遮挡,大大简化现场部署时间和降低施工费用。

2服务理念我司郑重承诺:您购买的不仅仅是产品,还有细致、周到的技术支持服务( =^_^= )本产品,现场只需普通工人安装即可! 无需调试!我们免费提供远程指导,远程配置调试服务,将数据发送至用户指定的云平台。

免费提供物联网方案咨询服务!3产品特性3.1温度采集特性采集类型:接触点温度温度量程:-50℃~+200℃(超高、超低温可定制)温度精度等级:0.5度采集频率:1分钟~24小时,支持远程配置3.2电气特性供电方式:电池供电 3.6V3.3通信特性无线传输方式:4G/NB-IOT/LoRa/WiFi通信协议:默认http推送数据转发:任意公网服务器3.4结构特性天线类型:吸盘式或胶棒式外置天线(可选内置天线)材质:PC塑料(外壳)主体防护等级:IP65主体尺寸:120mm×78mm×50mm测温探头结构:贴片式主体安装方式:壁挂或螺丝紧固探头安装方式:粘贴或螺钉紧固、扎带捆绑式安装3.5工作环境环境温度-25°C~75°C,湿度0~95%(非冷凝)4产品核心优势❖安装简单,快速部署,助力物联网项目快速落地❖支持远程配置❖非侵入式采集,不影响设备正常工作5平台对接可通过电信物联网平台进行对接。

光电传感器、光纤等电子产品参数说明说明书

光电传感器、光纤等电子产品参数说明说明书

Photoelectric SensorsFiber Optics2.124DiffuseUniversal 0.187" (4.75mm) Amplifier Tip Stainless Steel Jacket (T ype 302)PVC Jacket (Steel ReinforcedMiniature 0.086" (2.18mm) Amplifier Tip Stainless Steel Jacket (T ype 302)PVC Jacket (Steel Reinforced Thru-beamUniversal 0.187" (4.75mm) Amplifier Tip Stainless Steel Jacket (T ype 302)PVC Jacket (Steel ReinforcedMiniature 0.086" (2.18mm) Amplifier Tip Stainless Steel Jacket (T ype 302)PVC Jacket (Steel Reinforced)Sensing TipSensing Tip MaterialCable Length (Other Lengths available)Bend Radius, Stainless Steel Bend Radius, PVCOperating T emperature, Steel Operating Temperature, PVCFiber Core Diameter (48G Universal)Fiber Core Diameter (22G Miniature)Pull ForceSensing Mode NominalSensing RangeBOS 72K (22G)BOS 16K (48G)BFO 48G-DSV-SC-1BFO 48G-DSV-PC-1BFO 22G-DSV-SD-1BFO 22G-DSV-PD-1BFO 48G-TSV-SC-1BFO 48G-TSV-PC-1BFO 22G-TSV-SD-1BFO 22G-TSV-PD-1Side view Brass 1 m >25 mm >12 mm-45° C to +275° C -40° C to +105° C2.36 mm 1.57 mm 6.81 kgThru-beam 600 mm 350 mmDiffuse 80 mm 40 mmBFO 48G-DTA-SB-1BFO 48G-DTA-PB-1BFO 22G-DTA-SD-1BFO 22G-DTA-PD-1BFO 48G-TTA-SB-1BFO 48G-TTA-PB-1BFO 22G-TTA-SD-1BFO 22G-TTA-PD-1Threaded to smooth right angleBrass 1 m >25 mm >12 mm-45° C to +275° C -40° C to +105° C3.17 mm 1.57 mm 6.81 kgThru-beam 600 mm 500 mmDiffuse 140 mm 80 mmThru-beam 600 mm 500 mmBFO 48G-DT -SB-1BFO 48G-DT -PB-1BFO 22G-DT -SD-1BFO 22G-DT -PD-1BFO 48G-TT -SB-1BFO 48G-TT -PB-1BFO 22G-TT -SD-1BFO 22G-TT -PD-1Straight threadedBrass 1 m >25 mm >12 mm-45° C to +275° C -40° C to +105° C3.17 mm 1.57 mm 6.81 kgDiffuse 140 mm 80 mmNote : Thru-beam fiber optics are sold as individual cables. Two cables must be ordered to complete a pair. Consult factory for additional cable lengths.BFOGlass FibersThru-beam & DiffuseC o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o m/photoelectric BFO 48G-DN-SD-1BFO 48G-DN-PD-1BFO 22G-DN-SD-1BFO 22G-DN-PD-1BFO 48G-TN-SD-1BFO 48G-TN-PD-1BFO 22G-TN-SD-1BFO 22G-TN-PD-1NeedleStainless Steel (T ype 302)1 m >25 mm >12 mm-45° C to +275° C -40° C to +105° C1.57 mm 1.57 mm 6.81 kgThru-beam 600 mm 230 mmDiffuse 140 mm 50 mmApplication tip:application.C o u r t e s y o f C M A /F l o d y n e /H y d r a d y n e ▪ M o t i o n C o n t r o l ▪ H y d r a u l i c ▪ P n e u m a t i c ▪ E l e c t r i c a l ▪ M e c h a n i c a l ▪ (800) 426-5480 ▪ w w w .c m a f h .c o mPhotoelectricSensors Fiber Optics2.126BFO 48G-DS-SB-1 BFO 48G-DS-PB-1BFO 22G-DS-SD-1 BFO 22G-DS-PD-1BFO 48G-TS-SB-1 BFO 48G-TS-PB-1BFO 22G-TS-SD-1 BFO 22G-TS-PD-1Straight, Smooth BarrelBrass1 m>25 mm>12 mm-45° C to +275° C -40° C to +105° C3.17 mm1.57 mm6.81 kgNote: Thru-beam fiber optics are sold as individual cables. Two cables must be ordered to complete a pair.Consult factory for additional cable lengths.BFO 48G-DA-SB-1BFO 48G-DA-PB-1BFO 22G-DA-SD-1BFO 22G-DA-PD-1BFO 48G-TA-SB-1BFO 48G-TA-PB-1BFO 22G-TA-SD-1BFO 22G-TA-PD-1Right Angle SmoothBrass1 m>25 mm>12 mm-45° C to +275° C-40° C to +105° C3.17 mm1.57 mm6.81 kgBFO 48G-DAT-SB-1BFO 48G-DAT-PB-1BFO 22G-DAT-SD-1BFO 22G-DAT-PD-1BFO 48G-TAT-SB-1BFO 48G-TAT-PB-1BFO 22G-TAT-SD-1BFO 22G-TAT-PD-1Angle to ThreadedBrass1 m>25 mm>12 mm-45° C to +275° C-40° C to +105° C3.17 mm1.57 mm6.81 kgDiffuseUniversal 0.187" (4.75mm) Amplifier TipStainless Steel Jacket (T ype 302)PVC Jacket (Steel ReinforcedMiniature 0.086" (2.18mm) Amplifier TipStainless Steel Jacket (T ype 302)PVC Jacket (Steel ReinforcedThru-beamUniversal 0.187" (4.75mm) Amplifier TipStainless Steel Jacket (T ype 302)PVC Jacket (Steel ReinforcedMiniature 0.086" (2.18mm) Amplifier TipStainless Steel Jacket (T ype 302)PVC Jacket (Steel Reinforced)Sensing TipSensing Tip MaterialCable Length (Other Lengths available)Bend Radius, Stainless SteelBend Radius, PVCOperating T emperature, SteelOperating Temperature, PVCFiber Core Diameter (48G Universal)Fiber Core Diameter (22G Miniature)Pull ForceSensing ModeNominalSensing RangeBOS 72K (22G)BOS 16K (48G)Thru-beam600 mm500 mmDiffuse140 mm80 mmThru-beam600 mm500 mmDiffuse140 mm80 mmThru-beam600 mm500 mmDiffuse140 mm80 mmStainless Steel DiffuseStainless Steel Thru-BeamPVC Thru-BeamBFOGlass FibersThru-beam & DiffuseCyofCMA/Flodyne/Hydradyne▪MotionControl▪Hydraulic▪Pneumatic▪Electrical▪Mechanical▪(8)426-548▪www.cmafh.co m。

光电开关(光纤开关)..

光电开关(光纤开关)..
●灰尘较多的场所; ●腐蚀性气体较多的场所; ●水、油、化学品有可能直接飞溅的场所; ●户外或太阳光等有强光直射而无遮光措施的场所。 ●环境温度变化超出产品规定范围的场所; ●振动、冲击大,而未实行避震措施的场所。
多数光电开关选用的是波长接近可见光的红外线光波型。光电开关的重要功 能是能够处理光的强度变化:利用光学元件,在传播媒介中间使光束发生变 化;利用光束来反射物体;使光束放射经过长距离后瞬间返回。
光电开关的重要功能是能够处理光的强度变化:利用光 学元件,在传播媒介中间使光束发生变化;利用光束来 反射物体;使光束放射经过长距离后瞬间返回。光电开 关是由放射器、接收器和检测电路三局部组成。放射器 对准目标放射光束,放射的光束一般来源于发光二极管 〔LED〕和激光二极管。光束不连续地放射,或者转变 脉冲宽度。受脉冲调制的光束辐射强度在放射中经过屡 次选择,朝着目标不间接地运行。接收器有光电二极管 或光电三极管组成。在接收器的前面,装有光学元件如 透镜和光圈等。在其后面的是检测电路,它能滤出有效 信号和应用该信号。光电式接近开关广泛应用于自动计 数、安全爱护、自动报警和限位掌握等方面。 分类:光
电开关可分为对射型;漫反射型;镜面反射型;槽式光 电开关;光纤式光电开关。
一.对射型光电开关:由放射器和接收器组成,构造上是两者相互分别的, 在光束被中断的状况下会产生一个开关信号变化,典型的方式是位于同 一轴线上的光电开关可以相互分开达50米。 特征:区分不透亮的反光物体;有效距离大,由于光束跨越感应距离的 时间仅一次;不易受干扰,可以牢靠适宜的使用在野外或者有灰尘的环 境中;装置的消耗高,两个单元都必需敷设电缆。 二.漫反射型光电开关:是当开关放射光束时,目标产生漫反射,放射器 和接收器构成单个的标准部件,当有足够的组合光返回接收器时,开关 状态发生变化,作用距离的典型值始终到3米。 特征:有效作用距离是由目标的反射力量打算,由目标外表性质和和颜 色打算;较小的装配开支,当开关由单个元件组成时,通常是可以到达 粗定位;承受背景抑制功能调整测量距离;对目标上的灰尘敏感和对目 标变化了的反射性能敏感。

欧洲纽伯里电子感应传感器NJ10-30GM50-E2-V1-3G-3D的产品说明书

欧洲纽伯里电子感应传感器NJ10-30GM50-E2-V1-3G-3D的产品说明书

12R e l e a s e d a t e : 2 0 1 6 -1 1 -0 7 1 0 : 1 1D a t e o f i s s u e : 2 0 1 6 -1 1 -0 7 2 1 2 6 7 0 _ e n g . x m lPinoutL+L-13421 BN2 WH3 BU4 BKWire colors in accordance with EN 60947-5-2(brown)(white)(blue)(black)3R e l e a s e d a t e : 2016-11-07 10:11D a t e o f i s s u e : 2016-11-07212670_e n g .x m lInstructionManual electrical apparatus for hazardous areas Device category 3G (nA) for use in hazardous areas with gas, vapour and mist Certificate of ComplianceCE marking ATEX marking ¬ II 3G Ex nA IIC T6 GcThe Ex-related marking can also be printed on the enclosed label.Standards EN 60079-0:2012+A11:2013, EN 60079-15:2010 Ignition protection category "n"Use is restricted to the following stated conditionsG eneralThe apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed!Installation, commissioningLaws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indel-ible, including in the event of possible chemical corrosion.MaintenanceNo changes can be made to apparatus, which are operated in hazardous areas.Repairs to these apparatus are not possible.Special conditionsMaximum operating current I L The maximum permissible load current must be restricted to the values given in the fol-lowing list. High load currents and load short-circuits are not permitted.Maximum operating voltage U BmaxThe maximum permissible operating voltage UB max is restricted to the values in the following list. T olerances are not permissible.Maximum permissible ambient temperature T Umax dependant of the load current I L and the max. operating voltage U Bmax Information can be taken from the following list. at U Bmax =60 V , I L =200 mA 53 °C (127.4 °F) at U Bmax =60 V , I L =100 mA 56 °C (132.8 °F) at U Bmax =30 V , I L =200 mA 56 °C (132.8 °F) at U Bmax =30 V , I L =100 mA59 °C (138.2 °F)Protection from mechanical danger The sensor must not be exposed to ANY FORM of mechanical danger.Protection from UV light The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas.Protection against transients Ensure transient protection is provided and that the maximum value of the transient pro-tection (140% of 85 V) is not exceeded.Electrostatic chargeElectrostatic charges must be avoided on the mechanical housing components. Dan-gerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding.Material selection accessories When selecting accessories, ensure that the material allows the temperature of the enclosure to rise to up to 70 °C.Plug connectorThe plug connector must not be withdrawn under voltage. The proximity switch is identi-fied as follows: "WARNING - DO NOT SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e. the area that is inaccessible when the connector is inserted)4Releasedate:216-11-71:11Dateofissue:216-11-721267_eng.xml Note This instruction is only valid for products according to EN61241-0:2006 and EN61241-1:2004Note the ex-marking on the sensor or on the enclosed adhesive labelInstruction Manual electrical apparatus for hazardous areasDevice category 3DCE markingATEX marking ¬ II 3D Ex tD A22 IP67 T80°C XThe Ex-relevant identification may also be printed on the accompanying adhesive label.Standards EN 61241-0:2006, EN 61241-1:2004Protection via housing "tD"Use is restricted to the following stated conditionsG eneral The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual.The maximum surface temperature has been determined in accordance with method A without a dust layer on the equipment.The data stated in the data sheet are restricted by this operating instruction!The special conditions must be adhered to!Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal must be observed.If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediatevicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease!The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion! Maintenance No changes can be made to apparatus, which are operated in hazardous areas.Repairs to these apparatus are not possible.Special conditionsMaximum operating current I L The maximum permissible load current must be restricted to the values given in the following list.High load currents and load short-circuits are not permitted.Maximum operating voltage U Bmax The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. T olerances arenot permitted.Maximum permissible ambient tempera-ture T Umaxdependant of the load current I L and the max. operating voltage U BmaxInformation can be taken from the following list.at U Bmax=60 V, I L=200 mA 53 °C (127.4 °F)at U Bmax=60 V, I L=100 mA 56 °C (132.8 °F)at U Bmax=30 V, I L=200 mA 56 °C (132.8 °F)at U Bmax=30 V, I L=100 mA 59 °C (138.2 °F)Protection from mechanical danger The sensor must not be exposed to ANY FORM of mechanical danger.Protection from UV light The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor isused in internal areas.Electrostatic charge Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on themechanical housing components can be avoided by incorporating these in the equipotential bonding.Plug connector The plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: "WARNING - DO NOTSEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e.the area that is inaccessible when the connector is inserted)The plug connection can only be separated using a tool. This is achieved by using the locking protection V1-Clip (Mountingaccessory from Pepperl + Fuchs).5R e l e a s e d a t e : 2016-11-07 10:11D a t e o f i s s u e : 2016-11-07212670_e n g .x m lInstructionManual electrical apparatus for hazardous areas Device category 3D for use in hazardous areas with combustible dust Certificate of ComplianceCE marking ATEX marking ¬ II 3D Ex tc IIIC T80°C DcThe Ex-related marking can also be printed on the enclosed label.Standards EN 60079-0:2012+A11:2013, EN 60079-31:2014Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet.G eneralThe corresponding datasheets, declarations of conformity, EC-type examination certifi-cates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at . The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.Installation, commissioningLaws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The back-ground surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion!MaintenanceNo changes can be made to apparatus, which are operated in hazardous areas.Repairs to these apparatus are not possible.Special conditionsMaximum operating current I L The maximum permissible load current must be restricted to the values given in the fol-lowing list.High load currents and load short-circuits are not permitted.Maximum operating voltage U BmaxThe maximum permissible operating voltage UBmax must be restricted to the values given in the following list. T olerances are not permitted.Maximum permissible ambient temperature T Umax dependant of the load current I L and the max. operating voltage U Bmax Information can be taken from the following list. at U Bmax =60 V , I L =200 mA 53 °C (127.4 °F) at U Bmax =60 V , I L =100 mA 56 °C (132.8 °F) at U Bmax =30 V , I L =200 mA 56 °C (132.8 °F) at U Bmax =30 V , I L =100 mA59 °C (138.2 °F)Protection from mechanical danger The sensor must not be exposed to ANY FORM of mechanical danger.Protection from UV light The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas.Electrostatic chargeElectrostatic charges must be avoided on the mechanical housing components. Dan-gerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up.Plug connectorThe plug connector must not be withdrawn under voltage. The proximity switch is identi-fied as follows: "WARNING - DO NOT SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e. the area that is inaccessible when the connector is inserted)。

接近开关(传感器)

接近开关(传感器)

NEWS浅析接近开关(传感器)的选型与性能测定浅析接近开关的选型与性能测定摘要:文中阐述了接近开关的分类和结构,列叙述了光电式、超声波式接近开关的工作原理和适用范围。

从被检测物体的材质论述接近开关的选型及对接近开关的主要技术指标的测定方法。

关键词:分类结构设计选型性能检测1.概述接近开关是一种毋需与运动部件进行机械接触而可以操作的位置开关,当物体接近开关的感应面到动作距离时,不需要机械接触及施加任何压力即可使开关动作,从而驱动交流或直流电器或给计算机装置提供控制指令。

接近开关是种开关型传感器(即无无触点开关),它即有行程开关、微动开关的特性,同时具有传感性能,且动作可靠,性能稳定,频率响应快,应用寿命长,抗干扰能力强等、并具有防水、防震、耐腐蚀等特点。

产品有电感式、电容式、霍尔式、交、直流型。

接近开关又称无触点接近开关,是理想的电子开关量传感器。

当金属检测体接近开关的感应区域,开关就能无接触,无压力、无火花、迅速发出电气指令,准确反应出运动机构的位置和行程,即使用于一般的行程控制,其定位精度、操作频率、使用寿命、安装调整的方便性和对恶劣环境的适用能力,是一般机械式行程开关所不能相比的。

它广泛地应用于机床、冶金、化工、轻纺和印刷等行业。

在自动控制系统中可作为限位、计数、定位控制和自动保护环节。

接近开关具有使用寿命长、工作可靠、重复定位精度高、无机械磨损、无火花、无噪音、抗振能力强等特点。

因此到目前为止,接近开关的应用范围日益广泛,其自身的发展和创新的速度也是极其迅速。

2.接近开关的主要功能2.1检验距离检测电梯、升降设备的停止、起动、通过位置;检测车辆的位置,防止两物体相撞检测;检测工作机械的设定位置,移动机器或部件的极限位置;检测回转体的停止位置,阀门的开或关位置;检测气缸或液压缸内的活塞移动位置。

2.2尺寸控制金属板冲剪的尺寸控制装置;自动选择、鉴别金属件长度;检测自动装卸时堆物高度;检测物品的长、宽、高和体积。

欧洲品牌电磁感应传感器产品说明书

欧洲品牌电磁感应传感器产品说明书

Dimensions: [mm]Scale - 3:1760301106T e m p e r a t u r eT pT L760301106Cautions and Warnings:The following conditions apply to all goods within the product series of WE-GDT ofWürth Elektronik eiSos GmbH & Co. KG:General:•This electronic component is designed and manufactured for use in general electronic equipment.•Würth Elektronik must be asked for written approval (following the PPAP procedure) before incorporating the components into any equipment in fields such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc. where higher safety and reliability are especially required and/or if there is the possibility of direct damage or human injury.•Electronic components that will be used in safety-critical or high-reliability applications, should be pre-evaluated by the customer. •The component is designed and manufactured to be used within the datasheet specified values. If the usage and operation conditions specified in the datasheet are not met, the wire insulation may be damaged or dissolved.•Do not drop or impact the components, as the component may be damaged.•Würth Elektronik products are qualified according to international standards, which are listed in each product reliability report. Würth Elektronik does not warrant any customer qualified product characteristics beyond Würth Elektroniks’ specifications, for its validity and sustainability over time.•The responsibility for the applicability of the customer specific products and use in a particular customer design is always within the authority of the customer. All technical specifications for standard products also apply to customer specific products.Product specific:Soldering:•The solder profile must comply with the technical product specifications. All other profiles will void the warranty.•All other soldering methods are at the customers’ own risk.•Strong forces which may affect the coplanarity of the components’ electrical connection with the PCB (i.e. pins), can damage the component, resulting in avoid of the warranty.Cleaning and Washing:•Washing agents used during the production to clean the customer application might damage or change the characteristics of the wire insulation, marking or plating. Washing agents may have a negative effect on the long-term functionality of the product.•Using a brush during the cleaning process may break the wire due to its small diameter. Therefore, we do not recommend using a brush during the PCB cleaning process.Potting:•If the product is potted in the customer application, the potting material might shrink or expand during and after hardening. Shrinking could lead to an incomplete seal, allowing contaminants into the core. Expansion could damage the component. We recommend a manual inspection after potting to avoid these effects.Storage Conditions:• A storage of Würth Elektronik products for longer than 12 months is not recommended. Within other effects, the terminals may suffer degradation, resulting in bad solderability. Therefore, all products shall be used within the period of 12 months based on the day of shipment.•Do not expose the components to direct sunlight.•The storage conditions in the original packaging are defined according to DIN EN 61760-2.•The storage conditions stated in the original packaging apply to the storage time and not to the transportation time of the components. Packaging:•The packaging specifications apply only to purchase orders comprising whole packaging units. If the ordered quantity exceeds or is lower than the specified packaging unit, packaging in accordance with the packaging specifications cannot be ensured. Handling:•Violation of the technical product specifications such as exceeding the nominal rated current will void the warranty.•Applying currents with audio-frequency signals may result in audible noise due to the magnetostrictive material properties.•Due to heavy weight of the components, strong forces and high accelerations may have the effect to damage the electrical connection or to harm the circuit board and will void the warranty.•The temperature rise of the component must be taken into consideration. The operating temperature is comprised of ambient temperature and temperature rise of the component.The operating temperature of the component shall not exceed the maximum temperature specified.These cautions and warnings comply with the state of the scientific and technical knowledge and are believed to be accurate and reliable.However, no responsibility is assumed for inaccuracies or incompleteness.Würth Elektronik eiSos GmbH & Co. KGEMC & Inductive SolutionsMax-Eyth-Str. 174638 WaldenburgGermanyCHECKED REVISION DATE (YYYY-MM-DD)GENERAL TOLERANCE PROJECTIONMETHODWJK001.0072022-09-14DIN ISO 2768-1mDESCRIPTIONWE-GDT Gate-Drive-TransformerORDER CODE760301106SIZE/TYPE BUSINESS UNIT STATUS PAGEImportant NotesThe following conditions apply to all goods within the product range of Würth Elektronik eiSos GmbH & Co. KG:1. General Customer ResponsibilitySome goods within the product range of Würth Elektronik eiSos GmbH & Co. KG contain statements regarding general suitability for certain application areas. These statements about suitability are based on our knowledge and experience of typical requirements concerning the areas, serve as general guidance and cannot be estimated as binding statements about the suitability for a customer application. The responsibility for the applicability and use in a particular customer design is always solely within the authority of the customer. Due to this fact it is up to the customer to evaluate, where appropriate to investigate and decide whether the device with the specific product characteristics described in the product specification is valid and suitable for the respective customer application or not.2. Customer Responsibility related to Specific, in particular Safety-Relevant ApplicationsIt has to be clearly pointed out that the possibility of a malfunction of electronic components or failure before the end of the usual lifetime cannot be completely eliminated in the current state of the art, even if the products are operated within the range of the specifications.In certain customer applications requiring a very high level of safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health it must be ensured by most advanced technological aid of suitable design of the customer application that no injury or damage is caused to third parties in the event of malfunction or failure of an electronic component. Therefore, customer is cautioned to verify that data sheets are current before placing orders. The current data sheets can be downloaded at .3. Best Care and AttentionAny product-specific notes, cautions and warnings must be strictly observed. Any disregard will result in the loss of warranty.4. Customer Support for Product SpecificationsSome products within the product range may contain substances which are subject to restrictions in certain jurisdictions in order to serve specific technical requirements. Necessary information is available on request. In this case the field sales engineer or the internal sales person in charge should be contacted who will be happy to support in this matter.5. Product R&DDue to constant product improvement product specifications may change from time to time. As a standard reporting procedure of the Product Change Notification (PCN) according to the JEDEC-Standard inform about minor and major changes. In case of further queries regarding the PCN, the field sales engineer or the internal sales person in charge should be contacted. The basic responsibility of the customer as per Section 1 and 2 remains unaffected.6. Product Life CycleDue to technical progress and economical evaluation we also reserve the right to discontinue production and delivery of products. As a standard reporting procedure of the Product Termination Notification (PTN) according to the JEDEC-Standard we will inform at an early stage about inevitable product discontinuance. According to this we cannot guarantee that all products within our product range will always be available. Therefore it needs to be verified with the field sales engineer or the internal sales person in charge about the current product availability expectancy before or when the product for application design-in disposal is considered. The approach named above does not apply in the case of individual agreements deviating from the foregoing for customer-specific products.7. Property RightsAll the rights for contractual products produced by Würth Elektronik eiSos GmbH & Co. KG on the basis of ideas, development contracts as well as models or templates that are subject to copyright, patent or commercial protection supplied to the customer will remain with Würth Elektronik eiSos GmbH & Co. KG. Würth Elektronik eiSos GmbH & Co. KG does not warrant or represent that any license, either expressed or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right relating to any combination, application, or process in which Würth Elektronik eiSos GmbH & Co. KG components or services are used.8. General Terms and ConditionsUnless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms and Conditions of Würth Elektronik eiSos Group”, last version available at .Würth Elektronik eiSos GmbH & Co. KGEMC & Inductive SolutionsMax-Eyth-Str. 174638 WaldenburgGermanyCHECKED REVISION DATE (YYYY-MM-DD)GENERAL TOLERANCE PROJECTIONMETHODWJK001.0072022-09-14DIN ISO 2768-1mDESCRIPTIONWE-GDT Gate-Drive-TransformerORDER CODE760301106SIZE/TYPE BUSINESS UNIT STATUS PAGE。

线性技术无线传感器网络产品说明书

线性技术无线传感器网络产品说明书

Customer Fact Sheet on Wireless Sensor Networks – March 18, 2013Page 1LINEAR TECHNOLOGY CORPORATION • 1630 McCarthy Blvd, Milpitas, CA 95035-7417 • (408) 432-1900 • FAX: (408) 434-0507 • LINEAR TECHNOLOGY WIRELESS SENSOR NETWORKS CUSTOMER FACT SHEET FOR INTERNATIONAL SHIPMENTSWhat encryption products does Linear Technology Supply? Linear Technology SmartMesh Wireless Sensor Network (WSN) products are comprised of motes – nodes that are embedded into field devices, sensors, or actuators – and managers – devices embedded into gateways or controllers that manage a network of motes and provide a bridge to an outside network. Linear’s WSN hardware devices are made in several forms including bare circuit boards, packaged circuit boards, integrated circuits, and µmodules, and such devices typically contain embedded and/or accompanying software. Linear offers its WSN motes and mangers in the global license-free 2.4 GHz band to meet a range of requirements for industrial and commercial applications. Linear may also deliver “stand alone” software electronically or via CD in certain applications. Please refer to: /products/wireless_sensor_networks for additional details and product briefs.What export controls are applicable to Linear’s WSN products and why? Goods, software, and technology are all subject to the export control laws and regulations of the United States, including but not limited to the Export Administration Regulations (“EAR”). Certain Linear WSN products utilize encryption technologies which are subject to specific regulations and requirements. Please refer to: https:///policiesandregulations/index.htm#ear for specific details regarding encryption controls.What import controls are applicable to Linear’s WSN products and why? Certain countries have import permit or license requirements for the importation of encryption devices. For your convenience, some of these import controls are available on Linear’s website. This is not a complete and definitive list. Other requirements may exist. It is the customer’s responsibility to check with their local Customs Authority regarding import controls. Please refer to: /docs/39238 for specific details regarding some countries’ import controls. What encryption levels are used in Linear’s WSN products?Encryption use and security levels vary by product type and, accordingly, the specific Linear product(s) being utilized should be referred to in order to determine if and what encryption levels apply.What considerations apply due to the use of encryption technologies? There are many considerations, but of primary importance is classification and, if required, review by the U.S. Department of Commerce of the products for export control and reporting purposes. Please refer to: /docs/39238 for ECCN numbers, available License Exceptions, and CCATS.Where can Linear’s WSN products legally be shipped to? Are there any restrictions?The responsibility for ensuring export compliance is that of the exporter of the product. LinearTechnology will provide the ECCN number, CCATS number and advise of any License Exceptions that apply for shipment/export. Please also see above for import controls applicable to Linear’s WSN products.Please refer to: https:///policiesandregulations/index.htm#ear to ascertain whatrules/regulations apply for export to your desired destination.Are there implications for OEM Customers using Linear’s WSN?Linear constantly strives to improve is WSN products including security technology, and accordingly, the CCATS for WSN products may change from time to time. OEM’s should consult with their exportcompliance department, as well as related counsel, to account for this fact, and allow flexibility whenincorporating WSN products. Further, while Linear CCATS may be useful for OEM’s as a guideline, it isresponsibility of the OEM to certify and classify their own end products.Linear Technology Corporation Terms of SaleIn addition to Linear’s standard commercial terms of sale, the buyer acknowledges and agrees that thegoods, software, and technology subject to this Agreement are subject to the export control laws andregulations of the United States, including but not limited to the Export Administration Regulations(“EAR”), and sanctions regimes of the U.S. Department of Treasury, Office of Foreign Asset Controls. It is the responsibility of the buyer to adhere to all applicable U.S. laws and regulations.Please refer to: https:///policiesandregulations/index.htm#ear for furtherInformation, or contact your export compliance / legal counsel for assistance.Are there additional considerations related to international shipments of WSN products?Because Linear’s WSN products include radios which transmit and receive data, there may be countryspecific communication regulations which apply (e.g., the U.S. Federal Communications Commission, orFCC). These regulations vary by country and may impose additional compliance and/or regulatoryrequirements on the importer or exporter of the products.This overview is intended only as a tool to assist OEM’s in assessing Linear’s WSN products. Each OEM is responsible to ensure their WSN products meet applicable export requirements which may be different than those outlined herein as they pertain specifically to Linear’s products. This document does not provide legal advice. It is the responsibility of the OEM to consult with their own export compliance or legal counsel with any questions regarding export control requirements.Customer Fact Sheet on Wireless Sensor Networks – March 18, 2013 Page 2。

BNI IOL-104-002-Z046 IO-Link 1.1 传感器集线器 使用说明书

BNI IOL-104-002-Z046 IO-Link 1.1 传感器集线器 使用说明书

BNI IOL-104-002-Z046 IO-Link 1.1 Sensor hubwith extension portUser´s GuideContents1User Instructions 4 About this Manual 4 Structure of the Manual 4 Typographical Conventions 4 Enumerations 4 Actions 4 Syntax 4 Cross references 4 Symbols 4 Abbreviations 4 Differing views 4 2Safety 5 Intended use 5 Installation and Startup 5 General Safety Instructions 5 Resistance to aggressive substances 5 Hazardous voltage 5 3First Steps 6 Connection Overview 6 Mechanical Connection 7 Electrical Connection 7 Function ground 7 IO-Link connection 7 Connecting the sensor hub 8 Module variants 8 Sensor interface 8 Extension port 8 4General Configuration 9 Extension port 9 Extension port configuration 9 Setting the serial number 54hex 9 5Configuration: "Extension Off" 10 IO-Link data 10 Process Data/Input Data 10 Parameter Data / Demand Data 11 Parameter Data / Demand Data 11 Inversion of the inputs (40hex) 12 Voltage monitoring 44hex 12 6Configuration: Extended with BNI IOL-104-002-Z046 13 IO-Link data 13 Process Data/Input Data 13 Parameter Data / Demand Data 14 Parameter Data / Demand Data 14 Inversion of the inputs (40hex) 15 Voltage monitoring 44hex 16 Setting the serial number 54hex 17 7Diagnostics 18 Error Codes/ Errors 18 Events 18 8IO-Link functions 19 IO-Link Version 1.0 / 1.1 19 Data Storage 19 Block Configuration 19 Resetting to Factory Settings 199Technical Data 20 Dimensions 20 Mechanical Data 20 Electrical Data 20 Operating conditions 20 10Function indicators 21 Function indicators 21 LED indicator module status 21 Digital LED indicators for inputs/outputs 22 Extension port 22 11Appendix 23 Type code 23 Ordering information 231User InstructionsAbout this Manual This manual describes the Balluff IO-Link I/O module, also called a sensor/actuator hub.The IO-Link protocol is used to link to the higher-level master module.In terms of function, this compact, cost-effective module is similar to a passive splitter box; itrecords digital sensor signals and transmits them over the IO-Link interface. It passescontrol signals coming over IO-Link to the connected actuators.Structure of the Manual The manual is organized so that the sections build on one another. Chapter 2: Basic safety information.……..TypographicalConventionsThe following typographical conventions are used in this manual.Enumerations Enumerations are shown as a list with an en-dash.−Entry 1.−Entry 2.Actions Action instructions are indicated by a preceding triangle. The result of an action is indicated by an arrow.➢Action instruction 1.Action result.➢Action instruction 2.Syntax Numbers:Decimal numbers are shown without additional indicators (e.g. 123), hexadecimal numbersare shown with the additional indicator hex(e.g. 3F hex).Cross references Cross references indicate where additional information on the topic can be found. Symbols Attention!This symbol indicates a safety instruction that must be followed without exception.NoteThis symbol indicates general notes.Abbreviations BNIDPPI portEMCFEIOLLSBMSBSPDU Balluff Network Interface Direct Parameter Page Digital Input Port Electromagnetic compatibility Function groundIO-LinkLeast Significant BitMost Significant BitService Protocol Data UnitDiffering views Product views and images in this manual may differ from the product described. They are intended to serve only as illustrations.2SafetyIntended use The BNI IOL-… acts as a decentral sensor input module, which is connected by an IO-Link interface to a higher-level master module.Installation and Startup Attention!Installation and startup must only be carried out by trained technical personnel. Qualified personnel are people who are familiar with installation and operation of the product and have the necessary qualifications for these tasks. Any damage resulting from unauthorized tampering or improper use voids the manufacturer's guarantee and warranty. The operator must ensure that appropriate safety and accident prevention regulations are observed.General Safety Instructions Commissioning and inspectionBefore commissioning, carefully read the user's guide.The system must not be used in applications in which the safety of persons is dependent upon proper functioning of the device.Authorized personnelInstallation and startup must only be carried out by trained technical personnel.Intended useWarranty and liability claims against the manufacturer are rendered void by: −Unauthorized tampering−Improper use−Use, installation or handling contrary to the instructions provided in this user's guideObligations of the operating companyThe device is a piece of equipment in accordance with EMC Class A. This device can produce RF noise. The operator must take appropriate precautionary measures. The device may only be used with an approved power supply. Only use approved cables. MalfunctionsIn the event of defects and device malfunctions that cannot be rectified, the device must be taken out of operation and protected against unauthorized use.Intended use is ensured only when the housing is fully installed.Resistance to aggressive substances Attention!The BNI modules generally have a good chemical and oil resistance. When used in aggressive media (eg chemicals, oils, lubricants and coolants each in high concentration (ie, low water content)) must be checked prior application-related material compatibility. In the event of failure or damage to the BNI modules due to such aggressive media are no claims for defects.Hazardous voltage Attention!Before maintenance, disconnect the device from the power supply.NoteIn the interests of product improvement, Balluff GmbH reserves the right to change the technical data of the product and the content of this manual at any time without notice.3 First StepsConnection OverviewFigure 3-1: Connection overview BNI IOL-104-002-Z0461 Ground connection2 Mounting hole3 Status LED: communication4 Part label5 Port 16 Port 37 Port 58 Port 79 Port 9 10 Port 11 11 Port 1312 Port 15, extension port13 Pin/Port LED: signal status14 Port 14 15 Port 12 16 Port 10 17 Port 8 18 Port 6 19 Port 4 20 Port 2 21 Port 0 22 IO-Link Interface12 34 5672913101112 14 151617221819208213 First StepsMechanicalConnectionThe BNI IOL modules are attached using 2 max. M4 screws and 2 washers.Electrical Connection The BNI IOL-xxx-002-Z046 modules do not require a separate supply voltage connection. Supply voltage is provided via the IO-Link interface and the higher-level IO-Link master module.Function ground The modules are equipped with a ground connection.Figure 3-3: BNI ground connection IOL...➢Connect the sensor hub module to the ground connection.NoteThe FE-connection from the housing to the machine must have low impedanceand be as short as possible.IO-LinkconnectionThe IO-Link connection is established via an M12 connector (A-coded, male).IO-Link (M12, A-coded, male)Pin Requirement1 Supply voltage controller US, +24V2 Not used3 GND, reference potential4 C/Q, IO-Link data transmission channelAttention!Overcurrent. Defective or absent fusing of the supply voltage for the sensor andactuator will result in their damage or destruction.Use a fuse or an intelligent power supply (current monitoring designed formaximum 4 A) which turns off power when overcurrent is present.3 First StepsConnecting the sensor hub ➢Connect ground conductor to the FE terminal, if available.➢Connect the incoming IO-Link cable to the sensor hub.NoteA standardized sensor cable is used to connect to the higher-level IO-Link master module. Maximum length of 20 m.Module variants Sensor hub variants Digital portBNI IOL-104-002-Z046 IN Sensor interface PortPin FunctionIN1 +24V4 In3 0VNoteFor the digital inputs, the input guideline specified in EN 61131-2, Type 3 appliesNoteUnused input port sockets must be fitted with blind caps to ensure the IP67 degreeof protection.Extension port Extension port (M8, female)The port acts like a sensor interface if the extension function is deactivated.Pin FunctionIN1 +24V4 Communication3 0VNoteA standardized sensor cable is used to connect to the device/sensor to be extended. Maximum length of 20 m.4General ConfigurationExtension port The BNI IOL-104-002-Z046 module gives you the ability to use the No. 15 slot in variousways. By default it is used as a digital input slot, where Pin 4 can be used as a digital input.This slot can be used as an extension port by making a corresponding entry in theparameter with an index of 55hex. It is thus possible to run of the following modules via SlotNo. 15:•BNI IOL-104-002-Z046Extension port configurationConfiguration Value Index 55hexBNI IOL-104-002-Z046 0BNI IOL-104-002-Z046 with BNI IOL-104-002-Z046 1NoteThe "Factory reset" command does not affect the configuration of the extension portin any way.NoteThe process data length depends on the configuration.The extension port can be configured using the parameter 55hex (see table). If data storage or validation is used, validation (identical) must be used for configuring. Depending on the system, the Device ID has to be entered (parameter data table) or the Device ID is read out from the IODD.Setting the serial number 54hex The serial number has a default value of 16x00hex.In order to use the "Identity" master validation mode, aserial number can be set using this parameter.This prevents a device from connecting to the wrong master port.5Configuration: "Extension Off"IO-Link dataProcess Data/Input Data5 Configuration: "Extension Off"/ Demand DataParameter Data/ Demand Data5 Configuration: "Extension Off"inputs (40hex)0 – Normal1 - Inverted. Array Voltagemonitoring44hexBalluff Network Interface / IO-Link6Configuration: Extended with BNI IOL-104-002-Z046IO-Link dataData/InputDataBalluff Network Interface / IO-Link6 Configuration: Extended with BNI IOL-104-002-Z046/ Demand DataParameter Data/ Demand DataBalluff Network Interface / IO-Link6 Configuration: Extended with BNI IOL-104-002-Z046the inputs(40hex)0 - Normal1 - Inverted6 Configuration: Extended with BNI IOL-104-002-Z046monitoring44hex6 Configuration: Extended with BNI IOL-104-002-Z046Setting the serial number 54hex The serial number has a default value of 16x00hex.In order to use the "Identity" master validation mode, a serial number can be set using this parameter.This prevents a device from connecting to the wrong master port.7DiagnosticsError Codes/ErrorsEvents8IO-Link functionsIO-Link Version 1.0 / 1.1 This device can be operated with an IO-Link master according to IO-Link version 1.0 and version 1.1. Version-specific functions such as data storage (version 1.1) areonly supported in combination with a suitable IO-Link master.Data Storage Each IO-Link master of IO-Link version 1.1 features data storage in which an image of the IO-Link device configuration can be stored. When a device is replaced, the stored configuration isautomatically transferred to the new device. This guarantees minimal downtime. Validation mustbe switched on in order to use the data storage. For information about the configuration of datastorage and validation, please refer to the user's guide of the respective IO-Link master.Block Configuration The device supports block configuration. This allows all parameters in a data block to be consistently imported from a controller or a configuration tool into the device.Resetting to Factory Settings The factory settings on the device can be restored by running the "restore factory settings" system command.0x82 must be written to Index 2 Subindex 0 for the command.The extension port setting is not reset in this process.9Technical DataDimensionsMechanicalDataElectrical DataOperatingconditions10Function indicatorsFunctionindicatorsLED indicator module statusCOM/ US10 Function indicatorsDigital LED indicators for inputs/outputs LED 2, Input Pin 4Extension port The table is valid if the extension port is active. If the extension port is used as a standard I, then the description from "Digital LED indicators for inputs" can be used.11AppendixType codeOrdering informationType code Order codeBNI IOL-104-002-Z046BNI00AYBNI IOL-104-002-Z046 Balluff Network InterfaceIO-Link interfaceFunctions104 = 16 inputsVariants002 = with IO-Link 1.1 extension portMechanical configurationZ046 = Die-cast zinc, matte nickel platedBus connection: 1x M12x1 external threads,16 x M8x1 internal threadBalluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.F. Germany N o . 9 3 1 9 3 4 -7 2 6 E •0 1 . 1 3 1 0 5 7•E d i t i o n C 2 1•R e p l a c e s E d i t i o n J 1 6•S u b j e c t t o m o d i f i c a t i o n。

感应器产品说明书

感应器产品说明书

PANEL MOUNTFeatures• Ratings from 10A to 125A @ 24-280 VAC• SCR output for heavy industrial loads• Zero voltage or instantaneous turn-on outputs• UL/CSA/TUV Approved, CE Compliant to EN60950-1• Improved SEMS screw and washer• Redesigned housing with anti-rotation barriers• AC or DC control• Direct bond copper substrate• Direct power lead frame• Epoxy free designSERIES 1T | 240 VACOUTPUT SPECIFICATIONS(5)INPUT SPECIFICATIONS(5)GENERAL SPECIFICATIONS(5)WIRING DIAGRAMInput Current vs Input Voltage“T” Option - Low Voltage OutputInputCurrent(mA)DC Input VoltageInstantaneousTurn OnZero Turn OnEQUIVALENT CIRCUIT BLOCK DIAGRAMSDiagram: D24xxT Diagram: A24xxT, A24xxET-DC-DCMECHANICAL SPECIFICATIONS(5) Tolerances: ±0.02 in / 0.5 mmAll dimensions are in: inches [millimeters]Screw TerminationHex Standoff Termination (“K” Option)(2)Quick Connect Termination (“F” Option) - Up to 25 Amp (1)Quick Connect Termination (“F” Option) - Up to 50 Amp (1)20406080100120S u r g e C u r r e n t (A m p )Surge Duration (Secs)10 A50100150200250S u r g e C u r r e n t (A m p )Surge Duration (Secs)25 A100200300400500600S u r g e C u r r e n t (A m p )Surge Duration (Secs)50 A100200400300500600700900800S u r g e C u r r e n t (A m p )Surge Duration (Secs)15045030060075090012001050S u r g e C u r r e n t (A m p )Surge Duration (Secs)90 A30060090012001500S u r g e C u r r e n t (A m p )Surge Duration (Secs)110 A20040080060010001200140018001600S u r g e C u r r e n t (A m p )Surge Duration (Secs)125 ANon repetitive peak surge current at Tj initial 40ºC.Ambient Temperature (ºC)10 A3ºC/W5ºC/WNo HeatsinkAmbient Temperature (ºC)25 A1.5ºC/W2ºC/W3ºC/WAmbient Temperature (ºC)50 A0.7ºC/W1ºC/W1.5ºC/W2ºC/WAmbient Temperature (ºC)75 A0.5ºC/W 0.7ºC/W1ºC/W1.5ºC/WAmbient Temperature (ºC)90 A0.5ºC/W0.7ºC/W1ºC/W1.5ºC/WAmbient Temperature (ºC)110 A0.5ºC/W0.7ºC/W1ºC/W1.5ºC/WAmbient Temperature (ºC)125 A0.5ºC/W0.7ºC/W1ºC/WAGENCY APPROVALS AND CERTIFICATIONSEN60950 : Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7:Designed in accordance with the requirements of IEC 62314IEC 61000-4-2 : Electrostatic Discharge – Level 3IEC 61000-4-4 : Electrically Fast Transients – Level 3IEC 61000-4-5 : Electrical Surges – Level 3IEC 60068-2-6 : Vibration 0.33mm and 0.75 mm Amplitude over 10-55 Hz IEC 60068-2-27 : Shock Resistance 15g/11msE116949 LR81689 ACCESORIESPart number: KS101Clear plastic cover compatible with all new S1 designs. Safety covers provide added protection from electric shock when installing or checking equipment.Protective CoverHardware KitPart number: HK4Bag with 2 square brass accessories and 2 screw 8-32 x 5/8 for output. Used to mount TMR1 lug terminals.New Accessories!Protective Cover & Hardware KitsGENERAL NOTES(1) Single pair (up to 25A) Double pair* (up to 50A). *Caution: User must connect both pairs.(2) Option “K” is designed and tested for use with printed circuit boards or ring/fork terminals having a thickness between 0.031 and 0.093 inches (0.79 to 2.36 mm), and loads rated up to 50 Amps. For higher load currents, the “K” standoff temperature must not exceed 105°C. For additional application assistance please contact Crydom Technical Support. (3) Output will self trigger between 450-600Vpk, Min., not suitable for capacitive loads.(4) Instantaneous turn-on version is not recomended for capacitive loads. Use zero turn-on only.(5) All parameters at 25°C unless otherwise specified.(6) Heat sinking required, see derating curves.(7) For 40mA minimum current, the voltage drop increases over maximum rated.(8) Maximum turn-on voltage for -B option is: 1VDC for DC control, 10Vrms for AC control, and 4Vrms for E control range.(9) For relays with option “G” minimum control voltage is 4.5VDC.(10) Must turn-off voltage for -B option is: 3VDC for DC control, 90Vrms for AC control, and 18Vrms for E control range. (11) T urn-on time for Instantaneous turn-on versions is 0.02 msec (DC Control Models).(12) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report). (13) Load can be wired to either SSR output terminal 1 or 2.(14) Elective Input Status LED, “G” option.(15) Elective Overvoltage Protection, “P” option.(16) Mechanical dimensions vary from G3 models.For additional information or specific questions, contact Crydom Technical Support.(exept 110A & 125A models)CONTACT USSensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice.Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF.All products are sold subject to Sensata’s terms and conditions of sale supplied at SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, Americas+1 (877) 502 5500 – Option 2 ************************Europe, Middle East & Africa +44 (1202) 416170***********************Asia Pacific*************************.com China +86 (21) 2306 1500Japan +81 (45) 277 7117Korea +82 (31) 601 2004India +91 (80) 67920890Rest of Asia +886 (2) 27602006ext 2808WARNINGSRISK OF MATERIAL DAMAGE AND HOT ENCLOSURE• The product’s side panels may be hot, allow the product to cool before touching.• Follow proper mounting instructions including torque values.• Do not allow liquids or foreign objects to enter this product.Failure to follow these instructions can result in serious injury, or equipment damage.HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH• Disconnect all power before installing or working with this equipment.• Verify all connections and replace all covers before turning on power.Failure to follow these instructions will result in death or serious injury.Page 7。

电子接近传感器商品说明书

电子接近传感器商品说明书

1Proximity Sensors InductiveThermoplastic Polyester Housing Types EI, DC, M12, M18, M30•Euronorm thermoplastic polyester housing, cylindrical•Diameter: M12, M18, M30•Flush and non-flush types •Long and short body versions •Sensing distance:2 to 15 mm •Power supply: 10 to 40 VDC•Output:Transistor NPN/PNP , Normally open or Normaly closed•Protection: Short-circuit, reverse polarity and overload •LED-indication for output ON •2 m cable or M12 plugProduct DescriptionProximity switch in M12, M18and M30 polyester housings.Made in accordance witheuronorms EN 50 008 and EN 50 036.Type Selection DC Types, Cable and M12 PlugHousing Body Connection Rated Ordering no. Ordering no.Ordering no.diameter style operating Transistor NPN Transistor PNP Transistor PNP dist. (S n ) Normaly open Normaly open Normaly closedM12 Long Cable 2 mm 1) EI 1202 NPOPL EI 1202 PPOPL M12 Short Cable 4 mm 2) EI 1204 PPOPS M12 Long Cable 4 mm 2) EI 1204 NPOPL EI 1204 PPOPL M18 Short Cable 5 mm 1)EI 1805 PPOPS M18 Long Cable 5 mm 1) EI 1805 NPOPL EI 1805 PPOPL M18 Short Cable 8 mm 2) EI 1808 NPOPS EI 1808 PPOPS M18 Short Plug 8 mm 2) EI 1808 PPOPS-1M18 Long Cable 8 mm 2) EI 1808 NPOPL EI 1808 PPOPL EI 1808 PPCPL M18Long Plug 8 mm 2) EI 1808 PPOPL-1EI 1808 PPCPL-1M30 Long Cable 10 mm 1) EI 3010 NPOPL EI 3010 PPOPL EI 3010 PPCPL M30 Short Cable 15 mm 2) EI 3015 NPOPSM30 Long Cable 15 mm 2) EI 3015 PPOPL1)For flush mounting in metal 2)For non-flush mounting in metalSpecifications2EI, DC, M12, M18, M30DimensionsType A B (Ø mm) C (mm) D (mm) E (mm) F (mm)SW (mm)EI 1202 XPXPL M 12 x 1 x 50 10.7 50 11 5.0817EI 1204 XPXPS M 12 x 1 x 30 10.7 34 11 5.0817EI 1204 XPXPL M 12 x 1 x 50 10.7 54 11 5.0817EI 1805 XPXPS M 18 x 1 x 30 16.7 30 11.6 15.4824EI 1805 XPXPL M 18 x 1 x 50 16.7 50 11.6 15.4824EI 1808 XPXPS M 18 x 1 x 30 16.7 38 11.6 15.4824EI 1808 XPXPL M 18 x 1 x 50 16.7 58 11.6 15.4824EI 1808 XPXPL-1 M 18 x 1 x 5016.7 58 13.111.9824EI 3010 XPXPL M 30 x 1.5 x 50 28 50 13.6 15.41036EI 3015 XPXPS M 30 x 1.5 x 3028 42 13.6 15.41036EI 3015 XPXPL M 30 x 1.5 x 50 28 62 13.6 15.41036Specifications (cont.)Wiring DiagramsEI, DC, M12, M18, M30Installation HintsIncorrectCorrectThe cable should not be pulled A proximity switch should not serve as Any repetitive flexing of thecable should be avoidedPower SuppliesPower supplies VAC: > SS 110.Power supplies VDC: > SS 130/140.Power supplies with amplifier relays: > SV 190.3。

无线接近开关-无线光电开关使用说明

无线接近开关-无线光电开关使用说明

1 0 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5
7.8
time (ms)
125
164…
• 上述两者相结合的方式来进行传 播使传播数据更加稳定和可靠.
8
温度监视
多样化的供电方式
Link
Status
Flexpower 型节点内建电池管理功能,可采用多种供电方式。
0 OUT 1
0 OUT 2 D normal OUT 3 normal OUT 4
GATEWAY
Link Status
OK
D OUT 1
0
NODE 1
OUT 2 0
Link between Gateway and Node 1 timed out.
D OUT 1 normal
NODE 2
OUT 2 normal
7
GATEWAY
Good
4#
NID
8
GATEWAY
NODE
NID: 9 Device: 1
5#
NODE
NID: 9
NODE
NID: 8 Device: 2
NODE
NID: 7 Device: 2
NID
9
GATEWAY
NODE
NID: 8 Device: 1
支持的通讯协议有: ■ RS-485 Modbus RTU ■ Modbus TCP ■ Ethernet IP
节点与现场仪表和传感器连接,采集现场
数据,发送至网关。节点数量可灵活配
置,标准编址模式下最大可达15个节点。
最大可扩展至47个节点。单个节点提供最
大12路I/O.
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

【上海数采物联网科技有限公司】无线光电式接近开关产品说明书
版本:V 1.1
修订记录
目录
1 产品概述 (3)
2 产品特性 (4)
3 微功耗工作模式 (5)
3.1间隔时间模式: (5)
3.2整点模式 (5)
3.3持续工作模式 (5)
4 产品核心优势 (5)
5 通信协议 (6)
5.1协议解析说明 (6)
5.2协议接收测试 (6)
5.3协议定制 (6)
6 注意事项 (6)
7 附录 (6)
1产品概述
SC-GP-PS02是上海数采物联网科技有限公司研发的一款无线光电式接近开关传感器终端。

可向指定平台服务器以无线方式定时上报数据。

测量原理如下:利用被检测物对光束的遮挡或反射,由同步回路接通电路,从而检测物体的有无。

物体不限于金属,所有能反射光线(或者对光线有遮挡作用)的物体均可以被检测。

光电开关将输入电流在发射器上转换为光信号射出,接收器再根据接收到的光线的强弱或有无对目标物体进行探测。

安防系统中常见的光电开关烟雾报警器,工业中经常用它来计数机械臂的运动次数。

应用范围如机器人避障,流水线计数等。

终端采用GPRS/NB-IOT/Lora通信方式,克服现场特殊环境导致的无线通信遮挡,大大简化现场部署时间和降低施工费用。

设备工作状态分为休眠、采集存储、激活上报三种状态,也可以设置为持续工作状态,适用于外接电源供电的场景。

2产品特性
检测特性
检测距离:10~80cm可调
检测物体类别:透明或不透明物体
采集频率:1分钟~24小时,可设置
电气特性
供电方式:电池供电/12V 直流/220V 交流电池容量:3.6V*19Ah
待机功耗:小于10uA@3.6V
工作功耗:2~3mA@11V
发射功耗:150mA@11V
绝缘阻抗:>100MΩ(初/次级间)
通信特性
天线类型:外置天线(可选内置天线)
传输方式:GPRS/NB-IOT
通信协议:UDP推送,可定制其他协议
数据转发:任意公网服务器
结构特性
材质:PC塑料(外壳)
主体防护等级:IP65
主体尺寸:101mm×69mm×39mm
探头尺寸:长 65mm 直径18mm
主体安装方式:壁挂或螺丝紧固
探头安装方式:螺孔紧固
工作环境
温度-25°C~75°C,湿度0~95%(非冷凝)
存储环境
温度-30°C~90°C,湿度0~95%(非冷凝)
3微功耗工作模式
终端通过间歇工作的方式实现省电的效果,设备大部分时间处于待机状态,仅有极小一部分电路继续工作以保持在微功耗的状态。

这部分电路会保证系统时间的正确运行以及下次激活时间的正确记录。

设备每日的功耗计算:每日工作状态分为:待机状态和工作状态(唤醒采集数据并通过GPRS/NB-IOT方式上传数据),分别对应不同状态的功耗数据。

3.1间隔时间模式:
间隔时间模式是指由用户指定一定的间隔时间进行采样,并且在采样几次后进行上报。

该间隔时间应大于1分钟。

比如,某用户需要每10 分钟采集一次数据,在采集 6 次后进行上报,则以下两个参数可以分别设置为,采样间隔(M):10,采样N 次上报:6。

3.2整点模式
整点时间模式类似闹钟的工作原理,是针对时钟的0 点至23 点整时工作进行设置。

“采样时间”和“上报时间”按照整点时间从左到右依次代表23 点至0 点。

3.3持续工作模式
在外接12V电源情况下,可设置设备不休眠,一直处于工作状态。

4产品核心优势
◆自带电池,无需布线
◆安装简单,快速部署,助力物联网项目快速落地
◆支持任意物联网云平台,提供数据对接
◆非侵入式测量,不影响设备正常工作
◆支持远程配置,最大限度减少现场维护成本
5通信协议
5.1协议解析说明
默认UDP推送方式,用户接收数据需提供云端服务器公网IP地址和端口号。

数据报文示例:
8677260309944971#0#
报文解释:
5.2协议接收测试
可采用网络调试助手(net assistant)进行接收测试。

如下图。

如果接收数据乱码或异常,也可以采用网络调试助手进行发送测试。

设置好远程主机IP 端口,以ASIC方式发送数据,模拟传感器的数据发送。

5.3协议定制
如需定制其他对接协议,如MQTT、HTTP、对接组态软件等,可联系业务人员沟通。

6注意事项
(1)本产品内置SIM卡,每年流量费根据上报数据频率约10元。

也可采用用户自己的
SIM卡。

7附录
探头外观尺寸图(单位mm)。

相关文档
最新文档