安科瑞Acrel-3000系列电能管理系统产品手册

合集下载

AC300说明书

AC300说明书

目录1 引言 (4)1.1 编写目的 (4)1.2 注意事项 (4)2 启动 (4)3 初始界面 (4)4 应用程序结构与模块 (6)4.1 用户管理 (9)4.1.1 用户登记 (9)指纹登记 (13)ID(Mifare)卡登记 (13)原声录制 (14)拍照 (15)4.1.2 删除登记记录 (17)4.2 设置 (18)4.2.1基本设置 (18)时间设置 (18)语言设置 (18)语音提示 (18)音量调节 (19)按键音 (19)报警设置 (19)4.2.2 高级设置 (19)4.2.2.1 验证界面设置 (19)是否实时拍照 (19)是否显示照片 (19)实时指纹显示设置 (19)4.2.2.2删除全部记录 (19)4.2.2.3 删除全部登记数据 (20)4.2.2.4 恢复出厂设置 (20)4.2.2.5 固件升级 (20)4.2.2.6 夏令时设置: (20)4.2.2.7 功能键设置 (20)4.2.3 电源管理 (20)定时开机 (21)定时关机 (21)定时休眠 (21)响铃设置 (21)空闲设置 (21)锁闭关机键 (21)定时状态转换 (21)4.2.4 通讯设置 (22)机器编号 (22)RS232 (22)RS485 (22)波特率 (22)以太网 (22)IP地址 (22)子网掩码 (22)网关地址 (22)连接密码 (23)动态IP分配 (23)后台地址 (23)4.2.5 记录设置 (23)管理记录警告(报警) (23)验证记录警告(报警) (23)重复确认时间 (23)4.2.6 自动检测 (23)4.3门禁功能设置 (24)4.3.1 时间段设置 (24)4.3.2 分组功能设置 (25)4.3.3 用户门禁设置 (25)4.3.4 开锁组合设置 (26)开锁组合基本设置 (26)开锁组合设置 (26)4.3.5 锁驱动时长 (28)4.3.6 门磁延时 (28)4.3.7 门磁开关设置 (28)4.3.8 胁迫报警设置 (28)胁迫指纹管理 (28)验密码报警 (28)按键求助 (28)报警延迟 (29)4.3.9 错按报警 (29)4.3.10 反潜功能设置 (29)4.3.11 绑定ID (29)4.4 U盘管理 (29)4.5解除报警 (29)4.6系统信息 (30)4.6.1 用户登记数 (30)4.6.2 指纹登记数 (30)4.6.3 验证记录数 (30)4.6.4 管理记录数 (30)4.6.5 已用内存 (30)4.6.6 剩余容量 (30)4.6.7 设备信息 (30)4.7数据查询 (31)验证记录查询 (31)管理记录查询 (31)用户登记查询 (31)5外接端口连接方式 (31)5.1 外接端口总体描述 (31)5.2 连接说明 (32)5.2.1 RS232连接 (32)5.2.2 RS485连接 (32)5.2.3 出门开关连接 (33)5.2.4 门磁连接 (34)5.2.5 报警连接 (34)5.2.6 电锁连接 (35)5.2.7 电铃连接 (36)5.2.8 指纹读头连接 (37)6组网方式 (37)6.1 分体机组网方式 (38)6.2 一体机组网方式 (38)6.3 指纹读头组网方式 (38)7 终端设备组网调线方式说明 (39)7.1分体机调线连接方式图 (40)7.2一体机调线连接方式图 (41)8 控制器使用说明 (41)8.1 控制器外接端口图说明 (42)8.2 控制器连接说明 (42)8.2.1 出门开关连接 (42)8.2.2 门磁连接 (43)8.2.3 报警器连接 (43)8.2.4 电锁连接 (44)8.2.5 电铃连接 (46)9 基本概念与说明 (47)误判 (47)拒判 (47)权限级别 (47)状态键 (47)消息通知 (47)主从机 (48)夏令时(时区设置) (48)1 引言1.1 编写目的用户使用说明书.1.2 注意事项本考勤机不可阳光直射或强烈阳光下工作。

安科瑞Acrel-3000 6.0说明书

安科瑞Acrel-3000 6.0说明书
4.2 电力专用电力专用的 HMI 组态画面开发工具:.........................................................30 4.2.1 专用的电气组件:...............................................31 4.2.2 电力专用遥控组件:.............................................33 4.2.3 事件、报警子系统:.............................................35 4.2.4 电力专用报表系统:.............................................39 4.2.5 用户权限管理: ................................................41
Acrel-3000TM6.0 电力监控组态软件说明书
021-69526432
———————————————————————————————————————
安科瑞 Acrel-3000TM6.0
电力电气监控组态软件
使




上海安科瑞电气有限公司 2008 年 1 月 1 日
上海安科瑞电气有限公司

4.3 专用电力规约接口:.....................................................................................................42 4.3.1 支持电力规约: ................................................42 4.3.2 支持电力系统数据转发功能: ....................................44

安科瑞能耗监测系统说明

安科瑞能耗监测系统说明


能耗监测系统的数据编码
各地方标准的建筑总能耗的分类分项标准有差异,编码方法也有差别,系统可根据
各地标准灵活设置。
分类能耗 一级子类 分项能耗 一级子项 (1)室内照明与插座☆ (A)照明插座用电★ (2)公共区域照明和应急照明☆ (3)室外景观照明☆ 二级子项 (A)室内照明☆ (B)室内插座☆ (C)公共区域照明☆ (D)应急照明☆ (E)冷水泵★ (F)冷却水泵★ (G)冷水机组★ (H)冷却塔☆ (I)热水泵★ (J)电锅炉★ (K)空调箱、新风机组☆ (L)分机盘管☆ (M)空调区域的通排风设备☆ (N)多联机/分体式空调☆ -
表的二次接线,不应与计费电表串接。

能耗计量装置及设备选型
2、数字水表 功能:累计流量 精度:不低于2.5级 电气接口:RS-485、MBUS 通信协议:MBUS 安装位置:市政给水管网引入总管、建筑物内部独立经济核算单元、厨房餐厅、洗衣房、 游乐设施、公共浴池、绿化、洗车房、冷却塔、游泳池、水景等 管径:DN20 安装方式:破管安装,法来连接 要求:满足水平衡测试、不影响原系统供水流量,宜安装在便于检修、不受曝晒、水淹和 污染的地方。

整体结构
2、网络层/传输层
网络层由数据采集装置、组网设备、中继设备、隔离设备以及通信线缆组成。 计量装置和数据采集器之间采用主-从结构的半双工通信方式,采用符合各相关行业 标准的通信接口(RS485)及通信协议(MODBUS、645规约)。 计量装置和数据采集器之间传输距离较远时可增加中继设备,通过环网交换机组成 光纤环网增加传输的可靠性和安全性。 当能耗监测系统没有设置本地能耗监测管理系统时,传输层的智能数据采集器完成 能耗数据的采集、分类分项、编码、加密、数据上传等功能,数据可透传,不再购

智能配电保护系统及产品选型手册

智能配电保护系统及产品选型手册
11
时间元件:延时时间 2s 内误差≤40ms;延时时间大于 2s,误差≤(1%)整定值±40ms。 绝缘电阻:>100MΩ,500Vdc 介质强度:回路和地之间,独立回路之间:工频耐压 2KV 冲击电压:±5KV(1.2/50μs,0.5J) 符合标准:DLT 587-2007 微机继电保护装置运行管理规程
母联保 护及备
自投

√ ■
厂用变
110kV 及以下电压等级、容量为 6300kVA
电容器
PT 监测 PT 并列
压器
及以上的变压器
































Modbus-RTU/IEC60870-5-103









IRIG-B 对时






3)AM6 背部接线 ► AM6-D2 微机变压器差动保护
► AM6-T 微机变压器后备保护
AM6-D2 背部端子图
8
AM6-T 背部端子图 ► AM6-FD 微机变压器非电量保护 装置由五块插件组成: 方 案 一 : 一 个 非 电 量 输 入 插 件 (2X) , 一 个 非 电 量 输 出 插 件 (1X) , 三 个 操 作 回 路 插 件 (3X,4X,5X)。 方案二:两个非电量输入插件(2X,3X),一个非电量输出插件(1X),二个操作回路插件 (4X,5X)。 方案三:五个操作回路插件(1X,2X,3X,4X,5X)。 非电量输入插件原理图:

Acrel-3000电能管理系统在山东泰开变压器有限公司生产车间改造项目的应用

Acrel-3000电能管理系统在山东泰开变压器有限公司生产车间改造项目的应用

Acrel-3000电能管理系统在山东泰开变压器有限公司生产车间改造项目的应用安科瑞戴金花江苏安科瑞电器制造有限公司摘要:介绍山东泰开变压器有限公司生产车间改造项目,采用智能电力仪表、采集配电现场的各种电参量。

系统采用现场就地组网的方式,组网后通过现场总线通讯并远传至后台,通过Acrel-3000型电能管理系统实现车间配电箱配电回路用电的实时监控和管理。

关键词:车间配电箱;智能电力仪表;Acrel-3000;电能管理系统;0概述山东泰开变压器有限公司(简称:泰开变压器)是泰开集团有限公司的全资骨干子公司,专业生产750kV 及以下各类油浸电力变压器、干式变压器、特种变压器及电抗器等输变电设备专业大型骨干企业。

本次项目主要涉及山东泰开变压器有限公司生产车间改造项目中的各生产设备加装的多功能电表,后台主机位于现场值班室。

1需求分析为保证生产管理用电负荷的统计与分析及对危险源实时监控。

需要对项目现场的楼层配电箱等电气设备进行电压、电流、功率等参数进行实时在线监控。

一旦监控点被监视参数异常,能够及时检测报警,有关人员采取必要的措施,避免安全事故的发生。

自动抄表功能节省了人力物力,功率趋势曲线功能能够直观的显示各回路的工作状态与时间,方便用户找出非正常用电回路并且及时进行整改,建立电能多级计量体系提供用能分析依据。

本技术条件适用于山东泰开变压器有限公司生产车间改造项目的配电箱。

供方产品应具有高安全性与可靠性、易于扩展、便于维修与维护。

供方提供的产品应至少满足本技术条件,但不仅限于此,其技术性能应满足对车间配电箱数据监控的要求。

数据采集支持实时采集、自动周期采集(定时采集)可配置周期(1分钟~24小时)。

支持数据传输正确性检验,异常数据自动处理。

支持多线程处理机制,提高数据采集效率,能同时对多个设备进行数据采集。

数据实时显示采用配电箱主接线图直观显示模式,各回路开关断合以及故障状态直观可见。

数据分析与处理数据的综合统计、分析需要实现以下功能:各设备用电数据小时、日、月、年等时间段内的统计、计算。

Acrel.ARC系列功率因数补偿器说明书

Acrel.ARC系列功率因数补偿器说明书
本公司保留对本手册所描述之产品规格进行修改的权利,恕不另 行通知。订货前,请垂询当地代理商以获悉本产品的最新规格。
第一章
安装指南
1 网络电力仪表 1.1 简介
ARC 系列功率因数自动补偿控制器是低压配电系统补偿无功功率的专用控制器,可以与多 种等级电压在 400V 以下型号的静电容屏配套使用。输出路数有 6、8、10、12 路四种规格。产 品符合 JB/T9663-1999 国家标准,具有功能完善、运行稳定可靠、控制精度高等特点。
工作模式(P001)――接线方式(P002)――投入门限(P003)――切除门限(P004)―― 保护电压(P005)――谐波有功保护百分量(P006)――锁定电流(P007)――投切延时时间 (P008)――通讯地址(P009)――通讯波特率(P010)――最大许可路数(P011)――默认 显示画面(P012)――温度控制点(P013)――软件版本号(P014)
电流取自 A 线电流,标准额定输入电流为 5A,大于 5A 的情况应使用外部 CT; 虽然控制器具备自动相序判断功能,但还要尽量确保输入电压与输入电流相对应,即相号和 相序一致。 如果使用的 CT 上连有其它仪表,接线应采用串接方式; 去除产品的电流输入连线之前,一定要先断开 CT 一次回路或者短接二次回路! 5.3 安装 CT 建议使用接线排,不要直接接 CT,以便于拆装。 5.4 通讯接线 网络电力仪表提供异步半双工 RS485 通讯接口,采用 MODBUS-RTU 协议,各种数据讯息
5.7 温度控制接口(需另行配置) 控制器内部自带转换电路,外部只需连接一只 PT100 温度探头,一般 PT100 有三根出
线,请将其中两根同种颜色的电线并联,接线不分正反。温度控制输出(DO13 与 COM4) 可控制电容柜的风机,用以对电容进行通风降温。

EL3000中文使用手册

EL3000中文使用手册

表和售后服务的信息,并可以下载有关文件和软件工具的版本。
附件信息
如果这本手册没有提供某些特殊情况如何处理的信息,ABB 的售后服务会提供
用户的需要的额外信息。
请与当地的服务机构联系。若情况紧急,请联系。
ABB 售后服务
电话:+49-(0)180-5-222580,传真:+49-(0)621-38193129031
接地保护
仪表需要有接地保护。
未接地保护的危险
如果仪表的内部或外部未接地,或者是仪表未接地,它就很有可能受到损坏。
打开仪表盖的危险
当仪表的盖子或其他部件被打开时,所有电器件都暴露在外面,且都有电流。
仪表开盖操作的危险
只有训练有素、对仪表熟悉的工作人员才能在仪表开盖并上电时操作。
安全操作无须实施的情况
很显然,如果安全操作不需要,那么仪表就是不能操作了。 安全操作的情况不包含以下几点: z 如果仪表被损坏 z 如果仪表不能再使用 z 经过长期的储存并处于不利的状态下 z 运输过程中损坏
- 12 -
Ⅱ 3G等级的防爆设计
描述
备注:测量可燃性气体和蒸汽的分析仪表及带防爆装置并符合Ⅱ 3G 防爆要求 的分析仪表是 2 个不同的产品,应用在不同的场合中。
气体分析仪表-型号 EL3040,Ⅱ 3G 防爆等级,根据防爆保护要求测试,并 与技术参数表(见“安装现场的要求,供电”)和特殊要求(下附)相符。能 在危险区域中使用。 仪表可以用来测量非可燃气体和蒸汽,并遵循欧洲标准 94/9/EEC:
-7-
第一章 安装准备
现场安装的要求,供电
气路管路需尽量短
气体分析仪表需安装在靠近取样点的位置。
气源和标定系统需安装在气体分析仪表旁。

ACR系列网络多功能电力仪表安装使用说明书

ACR系列网络多功能电力仪表安装使用说明书

ACR系列网络多功能电力仪表安装使用说明书目录1 概述2 产品规格3 技术参数4 安装与接线4.1 外形及安装尺寸4.2 安装方法4.3 接线方法4.4 注意事项5 编程与使用5.1 测量项目及面板说明5.2 按键功能说明5.3 操作说明5.4 编程菜单5.4.1 仪表通用编程菜单5.4.2 LCD显示仪表增加的背光控制菜单5.4.3 带开关量仪表增加菜单5.4.4 带复费率仪表增加菜单5.5 编程示例5.5.1 如何修改电流变比5.5.2 如何修改变送设置6 通讯6.1 通讯协议概述6.1.1 传输方式6.1.2信息帧格式6.2 功能码简介6.2.1功能码03H或04H:读寄存器6.2.2功能码10H:写寄存器6.2. 3功能码x8H:读电能数据6.3 通讯应用细节6.3.1开关量输入与输出6.3.2电力参数与电能6.4 通讯地址表1 概述ACR系列网络多功能电力仪表,是针对电力系统,工矿企业,公用设施,智能大厦的电力监控需求而设计的一种智能表,它集成全部电力参数的测量(如单相或者三相的电流、电压、有功功率、无功功率、视在功率、频率、功率因数)以及全面的电能计量和考核管理(如四象限电能计量和分时电能统计、最大需量记录及12月电能统计等)。

同时它具有多种外围接口功能可供用户选择:带有RS485通讯接口,采用MODBUS-RTU协议可满足通讯联网管理的需要;4-20mA的模拟量输出可与任意测量的电参量相对应,满足DCS等接口要求;带开关量输入和继电器输出可实现断路器开关的“遥信”和“遥控”的功能,采用高亮度LED/LCD显示界面,通过面板按键来实现参数设置和控制,非常适合于实时电力监控系统。

ACR系列网络电力仪表具有极高的性能价格比,可以直接取代常规电力变送器及测量仪表。

作为一种先进的智能化、数字化的前端采集元件,该电力仪表已广泛应用于各种控制系统,SCADA 系统和能源管理系统中。

2 产品规格3 技术参数4 安装与接线4.1 外形及安装开孔尺寸(单位:mm)ACR1xx系列ACR2xx系列ACR3xx系列ACR4xx系列4.2 安装方法ACR系列网络电力仪表安装方式为嵌入式,固定方式为挤压式,具体操作如下:1、在配电盘上,选择适合的地方开一个与所安装多功能仪表开孔尺寸相同的安装孔;2、取出网络电力仪表,松开定位螺钉(逆时针),取下安装支架;3、把仪表插入配电盘仪表孔中,插入仪表后装上安装支架、定位螺钉(顺时针)。

ACR谐波表使用说明

ACR谐波表使用说明
1
IH 代代相电电电
Acrel
1
2
2
3
%
3
%
N
N kWh
3 4 DI 5 6 7 8 1
N 代代电电次功
kWh
3 4 DI 5 6 7 8
IMP
1 2
IMP
2
相相2-31次电电电电 1-Ua 2-Ub 3-Uc
相电2-31次电电电电 1-Ia 2-Ib 3-Ic
Ⅲ电网质量参数 仪表显示 ①相电压显示界面, 按 SET 键切换到 ③电压波峰系数界面后按左、 右键可切换显示其它界面: 电 压波峰系数←→电话波形因子←→电流 K 系数←→电压电流不平衡度。
5
Acrel
上海安科瑞电气有限公司
Acrel
Acrel
IMP
1 2 3 4 DI 5 6 7
kWh
8
IMP
1 2 3 4 DI 5 6 7
kWh
8
7.1.3 测量参数 Ⅰ电力参数
A:对三相四线系统,仪表上电后显示
①相电压,按左、右键可如下图切换显示其它界面:相电压←→线
电压←→电流←→总功率(功率因数)←→时间←→有功功率←→无功功率←→视在功率←→功率因数。
kWh
8 1
IMP
2 3 4 DI 5 6 7
kWh
8 1
IMP
2 3 4 DI 5 6 7
kWh
8 1
IMP
2 3 4 DI 5 6 7
kWh
8
注:以上各 SET 循环界面下文中用①,②,③,④,⑤ 表示
7.1.2 仪表开机瞬间显示为仪表版本信息:
仪表开机瞬间显示为仪表版本信息,之后即显示相电压界面

安科瑞Acrel-3000电能管理系统在成都河畔新世界项目的应用

安科瑞Acrel-3000电能管理系统在成都河畔新世界项目的应用

Acrel-3000电能管理系统在成都河畔新世界项目的应用徐霜上海安科瑞电气股份有限公司上海嘉定201801摘要:本文主要介绍了河畔新世界采用安科瑞智能电力仪表对配电现场的各种电参量和开关信号的采集,通过总线型组网方式,把数据上传至后台,进行智能化组网。

Acrel-3000电能管理系统在河畔新世界的应用,符合了国家对智能小区电能管理的要求,也为河畔新世界节约了大量人力成本,实现了小区电能管理智能化。

关键词:河畔新世界智能电力仪表Acrel-3000型电能管理系统1项目概况河畔新世界项目特邀香港知名国际设计师联手打造,充分利用成都锦江沿线连绵起伏的坡地风貌,于3000米超长河岸线上打造宽约25米的河堤景观。

一期为英式自然园林野趣自然花园、静思园、叠级花境园、观景亲水平台、太极草坪和儿童游乐园等十大主题大型景观各具特色。

电梯住宅为现代简约风格,采用梯形点阵式建筑布局、现代简约外立面、全架空建筑景观、下沉花园、绿色车库、户户江景、六米超高错层空中花园、入户花园、多功能房、独立保姆房等建筑设计,并选用豪华典雅单元入户宽敞候梯厅、德国BOSCH彩色可视对讲系统、LOW-E玻璃、鑫典钢木门等顶尖建筑用材。

安科瑞主要对河畔新世界地下室的4个低压配电房进行数据采集,值班室位于地下一层监控室内,4个低压配电房均通过光纤将数据进行上传,保障了现场数据传输的实时性和稳定性。

2用户需求客户要求电能管理系统软件的功能需满足:具有用户权限管理、一次主接线图实时监测与显示各回路的电参量、接入装置的一次设备的分合闸状态、电流实时曲线、回路超负荷报警、电度报表查询及打印功能。

根据客户要求,上海安科瑞电气股份有限公司需完成一套电能管理系统:主要对现场357台智能仪表进行电参量采集,完成对数据采集、曲线分析、报表打印等功能,并设置多权限操作,方便现场管理员的操作。

3设计方案上海安科瑞公司根据河畔新世界现场的实际情况为其选用了Acrel-3000电能管理系统。

江苏安科瑞电器制造有限公司 Acrel-6000 B3 型电气火灾监控设备 安装使用说明书

江苏安科瑞电器制造有限公司 Acrel-6000 B3 型电气火灾监控设备 安装使用说明书

345Acrel-6000/B3型电气火灾监控设备安装使用说明书V1.1江苏安科瑞电器制造有限公司危险和警告本设备只能由专业人士进行安装和维护,对于因不遵守本手册说明进行的违规操作所引起的故障,厂家将不承担任何责任。

触电、燃烧或爆炸的危险⏹设备只能由取得资格的工作人员才能进行安装和维护。

⏹对设备进行维护操作前,应隔离电源供应。

⏹要用一个合适的电压检测设备来确认电压已切断。

⏹在将设备通电前,应将所有的部件恢复原位。

⏹设备在使用中应提供正确的额定电压。

不注意这些预防措施可能会引起严重伤害。

申明:版权所有,未经本公司之书面许可,此手册中任何段落,章节内容均不得被摘抄、拷贝或以任何形式复制、传播,否则一切后果由违者自负。

本公司保留一切法律权利。

本公司保留对本手册所描述之产品规格进行修改的权利,恕不另行通知。

订货前,请垂询当地代理商以获悉本产品的最新信息。

目录1.概述 (2)2.基本功能 (2)2.1.监控报警功能 (2)2.2.控制输出功能 (2)2.3.故障报警功能 (2)2.4.自检功能 (2)2.5.报警记录存储查询功能 (2)2.6.电源功能 (2)2.7.远程控制功能 (3)2.8.权限控制功能 (3)3.主要技术参数 (3)3.1.电源 (3)3.2.工作制 (3)3.3.通讯方式 (3)3.4.监控容量 (3)3.5.监控报警项目 (3)3.6.故障报警项目 (3)3.7.控制输出 (3)3.8.自检项目 (3)3.9.事件记录 (4)3.10.操作分级 (4)3.11.使用环境条件 (4)4.设备组成部件 (4)4.1.主要参数及组成部件 (4)4.2.面板元件布置及功能说明 (4)5.安装与调试 (5)5.1.系统示意图 (5)5.2.设备安装 (5)5.2.1.环境 (5)5.2.2.安装方式 (5)5.2.3.设备尺寸 (5)5.3.接线 (6)5.4.单机调试 (6)5.5.系统调试 (7)6.使用说明 (8)6.1设备启动与登录 (8)6.2“隐患”页面操作 (10)6.3“状态”页面操作 (11)6.4“列表”页面操作 (12)6.5“事件”页面操作 (13)6.6“自检”页面操作 (14)6.7“维护”页面操作 (15)7.用户须知 (16)注意:本说明书针对Acrel-6000/B3型电气火灾监控设备及系统软件的使用进行全面介绍,用户使用前应仔细阅读,充分理解设备及系统软件的各项功能,以便正确、规范操作。

安科瑞3000WEB电能管理系统

安科瑞3000WEB电能管理系统

安科瑞3000-WEB电能管理系统1.平台概述1.1.前言随着国家电网改革政策的逐步推进和落实,Acrel-3000WEB电能管理解决方案运用互联网和大数据技术,为电力运维公司提供电能管理解决方案。

该平台作为连接运维单位和用电企业的纽带,全方位监视用户配电系统的运行状态和电量数据,为用户提供更好的运维服务。

平台提供用户概况、电力数据监测、电能质量分析、用电分析、日/月/年用能数据报表、异常事件报警和记录、运行环境监测等功能,并支持多平台、多终端数据访问。

1.2.技术标准本平台遵循以下标准开发:DL/T5430《无人值班变电站远方监控中心设计技术规程》GB/T2887《计算机场地通用规范》Q/GDW231《无人值守变电站及监控中心技术导则》《国家机关办公建筑和大型公共建筑能耗监测系统——分项能耗数据采集技术导则》《国家机关办公建筑和大型公共建筑能耗监测系统——分项能耗数据传输技术导则》《国家机关办公建筑和大型公共建筑能耗监测系统——楼宇分项计量设计安装技术导则》《国家机关办公建筑和大型公共建筑能耗监测系统——数据中心建设与维护技术导则》《国家机关办公建筑和大型公共建筑能耗监测系统——建设、验收与运行管理规范》《国家机关办公建筑和大型公共建筑能耗监测系统——软件开发指导说明书》1.1.适用场合本平台适用于电力运维单位,要求对变电所内的仪表、保护和环境传感器的遥测、遥信数据,实现运行状态、异常越限告警等监视与管理。

2.设计依据2.1.项目概况本次接入电能管理系统的变电所为广西大学1#楼实验室低压配电室、大学生创新实验中心大楼配电室、物理楼增容部分。

2.2.用户需求根据项目的实际情况,广西大学物理楼水电设施增容改造设备采购项目按照“安科瑞变电所运维云平台+数据托管方式”进行设计,由安科瑞指导用户或甲方完成硬件设备安装,安科瑞负责调试,将数据上传至安科瑞变电所运维云平台,委托安科瑞管理,免费托管三个月。

2.3.项目范围本次接入变电所运维云平台的变电所为广西大学1#楼实验室低压配电室、大学生创新实验中心大楼配电室、物理楼增容部分。

安科瑞电气 ACR系列 网络多功能电力仪表 说明书

安科瑞电气 ACR系列 网络多功能电力仪表 说明书
ACR系列网络多功能电力仪表
ACR Series Network Multi-functional Power Meters
总部: 上海安科瑞电气有限公司 Headquarter: Shanghai Acrel Co., Ltd. 地址:上海市嘉定区棕坊桥洪德路99号 Add:No. 99 Hongde Road, Zong Fang Qiao, Jiading District, Shanghai Tel:(86) 21-59104850 59104851 Fax:(86) 21-59104852 服务热线Service Hot Line: 800-820-6632 Http:// E-mail: ACREL001@ PC:201801 生产基地:江苏安科瑞电器制造有限公司 Production Base: Jiangsu Acrel Appliance Manufacture Co., Ltd. 地址:江阴市南闸镇东盟工业园区东盟路5号 Add:5 Domeng Road Dongmeng Industrial Park Nanzha town Jiangyin Tel:(86) 0510-86179966 86179967 86179968 Fax:(86) 0510-86179975 PC:214405 E-mail: JY-ACREL001@
ACR
Hale Waihona Puke ACR300E ACR310E ACR320E ACR320EL
ACR320EFL
ACR400E ACR410E ACR420E
基本功能 外形 可选功能 Outline Basic function Optional function 四象限电能计量;LED显示、RS485通讯 Four quadrant electric energy measu

IR3000 技术手册(中文版)

IR3000 技术手册(中文版)

IR3000 技术手册目录1.安装结构图与指南----------------------------3 5.3传感器-----------------------------261.1安装气动取样器--------------------4 5.4灯----------------------------------261.2法兰的安装结构-----------------------5 6诊断程序---------------------------------272 NIRG的通讯-----------------------------------6 6.1安装---------------------------------272.1设置电脑的以太网通讯--------------6 6.2调节主反光镜---------------------272.2 RS232通讯-----------------------------6 7修理故障----------------------------------282.3 以太网线的接线----------------------7 7.1LED和测试节点-------------------282.4 线缆装配RS232/485-----------------9 7.2以太网连接问题-------------------30 3仪器的软件设置-------------------------------93.1操作界面-------------------------------103.2设置-------------------------------------103.3设置测量-------------------------------113.3.1 测量方法--------------------123.3.2积分开始位置---------------133.3.3 积分宽度--------------------133.3.4中级过滤---------------------133.3.5平均样品---------------------133.3.6自动增益控制--------------133.3.7自动零位控制--------------133.4设置产品代码------------------------133.4.1常规参数--------------------133.4.2产品特定参数--------------143.4.3过滤--------------------------153.5设置Fieldbus-------------------------163.6设置串口和模拟输出---------------173.7以太网配置---------------------------183.8标定程序------------------------------193.8.1过程--------------------------203.8.2标定数据表-----------------203.8.3标定偏移方法--------------214操作界面/远端数字显示-------------------214.1重装操作系统------------------------214.2 LCD重新校准-----------------------224.3 配置-----------------------------------224.4 电子-----------------------------------224.5 更新软件-----------------------------234.6从因特网上更新软件---------------234.7远程显示值定标---------------------245 更换机械部件--------------------------------245.1主板/处理器/滤光转轮--------------255.1.1更换主板组件---------------255.2电源板----------------------------------26IR-3000 随机打包有2个可拆装的括号形的安装托架,它们可以被安装在不同位置以实现多样的安装方式。

Acrel 江苏安科瑞电器制造有限公司 ARCM300 型 电气火灾监控探测器 安装使用说明书

Acrel 江苏安科瑞电器制造有限公司 ARCM300 型 电气火灾监控探测器 安装使用说明书

171ARCM300型电气火灾监控探测器安装使用说明书V1.1江苏安科瑞电器制造有限公司Jiangsu Acrel Electric MFG.Co.,Ltd.申明DECLARATION版权所有,未经本公司之书面许可,此手册中任何段落、章节内容均不得被摘抄、拷贝或以任何形式复制、传播,否则一切后果由违者自负。

本公司保留一切法律权利。

本公司保留对本手册所描述之产品规格进行修改的权利,恕不另行通知。

订货前,请垂询当地代理商以获悉本产品的最新规格。

目录1概述 (1)2产品型号 (1)3技术参数 (1)4安装与接线 (2)4.1外形及安装尺寸 (2)4.2安装方式 (2)4.3接线说明 (3)4.4注意事项 (3)5编程与使用 (5)5.1测量项目及面板说明 (5)5.2LED指示说明 (5)5.3按键编程说明 (5)5.4液晶显示 (5)5.5编程 (7)6功能应用 (8)6.1剩余电流监测 (8)6.2温度保护 (8)6.3自检功能 (8)6.4消音功能 (8)6.5报警复位(解除报警) (8)6.6集中监控 (9)7通讯协议 (9)7.1通讯协议概述 (9)7.2功能码简介 (10)7.3探测器参数地址表 (11)8典型应用及附件 (13)8.1典型接线图 (13)8.2分级保护应用原则 (13)8.3AKH-0.66L系列剩余电流互感器选型 (13)8.4NTC温度传感器 (14)9注意事项 (14)1概述ARCM300型电气火灾监控探测器是针对0.4kV 以下的TT 、TN 系统设计的,通过对配电回路的剩余电流、导线温度等火灾危险参数实施监控和管理,从而预防电气火灾的发生。

产品采用先进的微控制器技术,集成度高,体积小巧,安装方便,集智能化,数字化,网络化于一身,是建筑电气火灾预防监控、系统绝缘老化预估等的理想选择。

产品符合GB14287.2-2014《电气火灾监控系统第2部分:剩余电流式电气火灾监控探测器》、GB14287.3-2014《电气火灾监控系统第3部分:测温式电气火灾监控探测器》的标准要求。

OPEN-3000系统使用手册-SCADA

OPEN-3000系统使用手册-SCADA

OPEN-3000能量管理系统系统使用手册之SCADA国电南瑞科技股份有限公司二零零七年八月前言本手册是OPEN-3000系统SCADA部分的使用说明,结合工程化工作将各类编辑工具的使用操作进行了较为详细的说明。

该手册主要适用于初次使用OPEN-3000SCADA系统的人员以及系统工程化人员,同时也可以作为SCADA工具使用的速查手册,希望对使用OPEN-3000系统者有所帮助。

鉴于系统相应软件功能在不断更新,所以本手册也会随之做定期相应更新和完善。

目录第一章 SCADA基本概念 (1)1.1SCADA操作相关概念 (1)1.2SCADA遥测质量码 (2)1.3SCADA遥信质量码说明 (2)第二章 SCADA数据库表定义 (4)2.1SCADA数据库表简介 (4)2.1.1 系统类 (4)2.1.2 设备类 (4)2.1.3 参数类 (4)2.1.4 计算类 (4)2.2触发关系设置 (4)2.2.1 总体定义流程 (5)2.2.2 遥信触发设置 (5)2.2.3 遥测触发设置 (6)第三章 SCADA界面工具 (11)3.1事故反演界面 (11)3.2实时数据显示界面 (16)3.2.1 启动与退出 (16)3.2.2 功能详解 (17)3.3分量显示界面 (17)3.3.1 启动与退出 (17)3.3.2 功能详解 (18)3.4极值统计及回顾界面 (19)3.4.1 启动及退出 (19)3.4.2 功能详解 (20)3.4.3 操作步骤 (21)第四章 SCADA应用操作 (22)4.1通用菜单操作 (22)4.1.1 厂站全遥信对位 (22)4.1.2 厂站全遥测解封锁 (22)4.1.3 厂站全遥信解封锁 (22)4.1.4 厂站抑制告警/厂站告警恢复 (22)4.1.5 厂站告警 (22)4.1.6 系统全遥信对位 (23)4.1.7 召唤全数据 (23)4.2设备菜单操作 (23)4.2.1 母线 (23)4.2.2 开关 (25)4.2.3 间隔 (33)4.2.4 刀闸 (35)4.2.5 变压器 (38)4.3遥测量操作 (42)4.3.1 参数检索 (42)4.3.2 遥测封锁 (42)4.3.3 解除封锁 (43)4.3.4 遥测置数 (43)4.3.5 数据多源 (44)4.3.6 历史数据信息 (45)4.3.7 前置信息 (45)4.3.8 遥测越限 (46)4.3.9 今日曲线 (46)4.3.10 实时曲线 (46)4.3.11 曲线合并 (47)1.3.12 曲线右合并 (48)4.3.13 对比曲线 (49)附:SCADA数据库表说明 (50)1 系统类 (50)1.1行政区域表 (50)1.2厂站信息表 (50)2 设备类 (51)2.1断路器信息表 (51)2.2刀闸信息表/接地刀闸信息表 (52)2.3保护节点表 (52)2.4测点遥信信息表 (53)2.5母线表 (53)2.6变压器表 (54)2.7变压器绕组表 (54)2.8发电机表 (55)2.9负荷表 (55)2.10容抗器表 (55)2.11线路表 (56)2.12交流线段表 (56)2.13交流线段端点表 (56)2.14终端设备表 (57)2.15测点遥测信息表 (57)3 参数类 (57)3.1遥测定义表 (57)3.2遥信定义表/二次遥信定义表 (58)3.3遥脉量表 (58)3.4遥控关系表 (58)3.5档位遥信关系表 (59)4 计算类 (60)4.1计算值表 (60)4.2限值表 (60)4.3时段表 (61)4.4限值定义表 (61)4.5限值上限表/限值下限表 (61)4.6特殊计算表 (62)4.7跳变事故定义表 (63)4.8点多源表 (63)4.9极值潮流统计定义表 (64)4.10电度量表 (64)第一章 SCADA基本概念SCADA是架构在统一支撑平台上的应用子系统,是OPEN-3000的最基本应用,用于实现完整的、高性能的实时数据采集和监控,为其他应用提供全方位、高可靠性的数据服务。

电源专家电能表3000系列商品说明说明书

电源专家电能表3000系列商品说明说明书

Power Xpert Meter 3000 SeriesGeneral descriptionThe Power Xpert® Meter 3000 Series powerquality and energy meters monitor the mostcritical aspects of an electrical distribution system.This premier metering instrument uses the latestin advanced technology to make it simple to use,powerful, scalable, and highly flexible.ApplicationsIdentify power quality problems to help:• Protect motors from damage• Preserve the integrity of processes and batches• Prevent blown capacitor bank fuses• Protect transformers and conductorsfrom overheatingMonitor circuit loading to help:• Avoid overloads and nuisance overload trips• Maximize equipment utilization• Manage emergency overloadsManage energy utilization to help:• Reduce peak demand charges and powerfactor penalties• Identify excessive energy consumptionFeatures• 100 ms refresh, true rms measurement• ANSI C12.20 (0.2 Class) and IEC 62053-22(0.2S Class)• 1.5 GB onboard memory• Power quality analysis - Sag/Swell recording• Over/under limit alarm• Supports Modbus® RTU, DNP 3.0 via RS-485• Modbus TCP and BACnet/IP• Digital Input status monitoring via webpage andremote communication• Waveform capture (128 points per cycle), wave-form captures in COMTRADE file format.• Measure individual harmonics from 2nd to 63rd• 50/60 Hz rated frequency metering• Modular design• Integrated data logging plus three custom datalogs• TOU (time of use), 4 tariffs, 12 seasons, 14schedules2Technical Data TD0262032ENEffective January 2022Power Xpert Meter 3000 SeriesEATON Metering• Voltage V1, V2, V3, VLNavg, V12, V23, V31, VLLavg • Current I1, I2, I3, In, Iavg • Power P1, P2, P3, Psum• Reactive power Q1, Q2, Q3, Qsum • Apparent power S1, S2, S3, Ssum • Frequency F• Power factor PF1, PF2, PF3, PF•Energy EP_imp, EP_exp, EP_total, EP_net, EPa_imp, EPa_exp, EPb_imp_EPb_exp, EPc_imp, EPc_exp•Reactive energy EQ_imp, EQ_exp, EQ_total, EQ_net, EQa_imp, EQa_exp, EQb_imp, EQb_exp, EQc_imp, EQc_exp • Apparent energy ES, ESa, ESb, ESc• Demand Dmd_P , Dmd_Q, Dmd_S, Dmd_I1, Dmd_I2, Dmd_I3• Load type, inductive or capacitive •Four quadrant powerMonitoring• Power quality• Voltage harmonics 2nd to 63rd and THD • Current harmonics 2nd to 63rd and THD • Voltage crest factor• Telephone interference factor (TIF)• Current K factor• Voltage unbalance factor U_unbl • Current unbalance factor I_unbl •Max./min. statistics with time stampsAlarmsLimits can be set for up to 16 parameters and can be set with a specified pickup delay time interval. If any input of the indicated parameters is over or under its setting limit and persists over the specified time interval, the event will be recorded with time stamps and trigger the alarm DO output. The 16 parameters can be selected from any of the 80 parameters available.I/O option moduleA maximum of two modules can be used for one meter.Time of useUsers can assign up to four different tariffs (sharp, peak, valley, and normal) to different time periods within a day according to the Utility TOU rate structure. The meter will calculate and accumulate energy for the programmed rate periods based on the TOU settings.Power quality event loggingWhen a power quality event happens, such as voltage sag and swell, PXM 3000 will record the timestamp and the triggering condition of the event. It can save up to 50,000 power quality events.Automatic frequency adaptationRated frequency is adjusted automatically to local frequency such as 50 Hz or 60 Hz. The same meter can be applied in countries with different electrical frequencies.Display• Clear and large character LCD screen display with white backlight • Wide environmental temperature endurance•Display load percentage, four quadrant power, and load type,inductive or capacitive•Small size 96 × 96 DIN or 4-inch ANSI round panel cutoutsPower Xpert Meter 3000 embedded web serverThe Power Xpert Meter 3000 embedded Web server offers Eaton® customers accessibility to the critical information required to manage their electrical distribution system. The web server includes real-time information in both numeric and graphical visual formats to help monitor parameters such as current loading, voltage and power levels, power factor, THD, and more. The web server also provides energy and demand readings with graphic usage plots to helpanalyze energy usage patterns. Energy readings include kWh, kvarh, delivered and received and kVAh. Webserver also provides ability to view Sag/Swell waveforms.Waveform recordingThe Power Xpert Meter 3000 can record waveforms for 20 cycles up to 128 samples per cycle.Waveform capturePXM 3000 can record 100 groups of voltage and current waveforms. It logs at 64 points per cycle. (200 groups of voltage and current waveforms in case of 64 points per cycle and 100 groups of voltage and current waveform in case of 128 points per cycle). It provides the waveform record of 10 cycles before and after the triggering point.It also supports a settable triggering condition.Waveform captures are automatically stored on the FTP server in the IEEE standard COMTRADE file format. This allows users to view and analyze the waveforms in any standard free-of-charge orcommercial COMTRADE file viewer.3Technical Data TD0262032ENEffective January 2022Power Xpert Meter 3000 Series EATON Historical trend loggingThe Power Xpert Meter 3000 records historical data for graphical viewing from the embedded Web server. Graphical views ofhistorical data support pan and zoom. Over 100 standard metering parameters are logged as part of the standard meter functionality including min/max and average for each parameter. The averages are calculated over the interval period. In addition to the standard logs, the PXM3000 also includes three custom data logs that can be configured and viewed via the web interface.Load profile dataThe Power Xpert Meter 3000 records average real, reactive and apparent power. These readings are stored on a fixed five minute interval. Up to four status inputs can be configured as energy accumulators for counting KYZ pulse inputs.Demand comparisonsDemand usage patterns can be analyzed with the month-to-month, week-to-week, day-to-day comparison chart built into the meter. Raw data can be exported as a .csv file with the “download” option to other applications for further analysis and graphing.Alarm triggersThe Power Xpert Meter 3000 has configurable alarm triggers.The meter limits can be set for any measured parameter, for up to 16 limits. If any of the 16 limits are exceeded, an alarm condition will be present and can cause the backlight to flash on the meter faceplate if desired. The meter out of limits can also be used to energize a relay output, when meter is equipped with optional I/O module.Event loggingThe Power Xpert Meter 3000 embedded web server allows the user to view a list of triggered events. In addition, a separate system log records system operations such as resets. Monitoring and time stamping of digital inputs enables the user to compare the sequence of digital input transitions.EmailThe Power Xpert Meter 3000 contains the ability to send emails based on an event and / or alarm that has been triggered or cleared.Displayed information•Monitored information is available locally through the display, the web browser or system power management software.• True rms values through 63rd harmonic.•ANSI C12.20 Class 0.2% revenue metering specification.Power Xpert Meter 3000 web browser viewsPower Xpert Meter 3000’s embedded web server Overviewscreen allows a quick view of critical electrical parameters. These parameters are placed on a chart that allows customers to easily identify real time, as well as the mean with +/- 3 standard deviation values. They also can see the events log and demand.The web server offers a waveform view to visualize disturbances such as voltage sags that can cause costly business interruptions.The harmonic spectral plot displays harmonics up to the 63rd order. Individual harmonics andTHD are displayed for diagnostic purposes.4Technical Data TD0262032ENEffective January 2022Power Xpert Meter 3000 SeriesEATON Graphical trending of dataThe Power Xpert Meter 3000 embedded web server supportsgraphical trend charts of key circuit measurements such as current, voltage, power and energy. The trend chart supports a zoom feature that allows the user to view data over a short period of 16 hours or a longer period of 48 months. The trend chart has a horizontal slider bar control to manage scrolling forward and backward through the data. Trend charts of basic readings include minimum, maximum, and average readings. Trend charts of energy data also display demand values.Energy Managers can view load profile data compared against the peak demand.Data loggingThe PXM 3000 meters contain 1.5GB of memory for data logging and historical trending. Since each meter contains a real-time clock, all events and logged data will be time stamped.The PXM 3000 meters have three sets of historical data logs. Each log can be independent l y programmed with individual settings,meaning that each can be used to monitor different parameters. The user can program up to 117 parameters per log.Web server device configurationSpecial software is not required to configure a Power Xpert Meter 3000. The embedded web server includes a comprehensive device configuration engine.CommunicationsThe communications card provides one ethernet connection via a 10/100Base-T port (copper only) that can be used for the following applications:•Monitoring, managing, and configuring the meter remotely using a standard web browser interface.• Alarm notifications via email, SMTP .•Providing Modbus TCP/IP , and BACnet/IP communications to BMS systems.• Providing SNMP communications to NMS systems.• Synchronizing with an NTP server.•Updating firmware on the meter.The card also contains a micro USB port for programming and monitoring. The USB port allows access to the meter’s web interface.Figure 1. PXM 3000 rear view.1 Power supply inputs2 RS-4853 Current inputs 4Micro USB5 Ethernet345Technical Data TD0262032ENEffective January 2022Power Xpert Meter 3000 Series EATON ParametersCategoryItemParametersPXM 3000MeteringReal-time meteringPhase voltage V1, V2, V3, VLnavg n Line voltage V12, V23, V31, Vllavg n Current I1, I2, I3, In, Iavg n Power P1, P2, P3, Psum n Reactive power Q1, Q2, Q3, Qsum n Apparent power S1, S2, S3, Ssum n Power factor PF1, PF2, PF3, PF n FrequencyFn Energy and demandEnergy Ep_imp, Ep_exp, Ep_total, Ep_net, Epa_imp, Epa_exp, Epb_imp, Epb_exp, Epc_imp, Epc_expn Reactive energy Eq_imp, Eq_exp, Eq_total, Eq_net, Eqa_imp, Eqa_exp, Eqb_imp, Eqb_exp, Eqc_imp, Eqc_exp n Apparent energy Es, Esa, Esb, Escn DemandDmd_P, Dmd_Q, Dmd_S, Dmd_I1, Dmd_I2, Dmd_I3n TOU Time of use Energy/max. demand TOU, 4 tariffs, 12 seasons, 14 schedules n Daylight saving timeTwo adjustable formats Month/day/hour/minuteMonth/week/first few weeks/hour/minuten MonitoringWaveform capture Voltage and current waveform*Trigger, manual, DI change, sag/dips, swell, overcurrent n Power qualityVoltage unbalance factor U_unbl n Current unbalance factor I_unbln Voltage THD THD_V1,THD_V2,THD_V3, THD_Vavg n Current THD THD_I1, THD_I2, THD_I, THD_Iavg n Individual harmonics Harmonics 2nd to 63rd (50 Hz or 60 Hz)n Voltage crest factor Crest factorn TIFTelephone interference factor n Current K factorK factorn StatisticsMAX with time stamp MIN with time stamp Each phase of V & l; Total of P, Q, S, PF & F; demand of I1, I2, I3, P, Q&S; each phase THD of V & I; unbalance factor of V & In OthersAlarmOver/under limit alarmV, I, P, Q, S, PF, V_THD and I_THD each phase and total or average; unbalance factor of V and I; load type; analog input of each channel; demand of I1, I2, I3, P, Q&S; reverse phase sequence; DI1~DI28nPower quality event logging Sag/dips, swell Voltagen Data loggingData logging 1Data logging 2Data logging 3F, V1/2/3/avg, V12/23/13/avg, I1/2/3/n/avg, P1/2/3/sum, Q1/2/3/sum, S1/2/3/sum, PF1/2/3, PF, U_unbl, I_unbl, Load Type, Ep_imp, Ep_exp, Ep_total, Ep_net, Eq_imp, Eq_exp, Eq_total, Eq_net, Es, Epa_imp, Epa_exp, Epb_imp,Epb_exp, Epc_imp, Epc_exp, Eqa_imp, Eqa_exp, Eqb_imp, Eqb_exp, Eqc_imp, Eqc_exp, Esa, Esb, Esc, THD_V1/2/3/avg, THD_I1/2/3/avg, harmonics 2nd to 63rd, crest factor, THFF, K factor, sequence and phase angles, DI counter, AI, AO, Dmd P/Q/S, Dmd I1/2/3nOnboard memory size Memory Bytes1.5 GBCommunication RS-485 port, half duplex, optical isolated, RJ-45 Ethernet, Micro USB Modbus ®-RTU protocol/DNP3.0, Modbus TCP, BACNet IP nTimeReal-time clockYear, month, date, hour, minute, secondn6Technical Data TD0262032ENEffective January 2022Power Xpert Meter 3000 SeriesEATON AccessoriesDigital/analog I/OIntegrate data to/from other devices with field expandableplug-in I/O modules. A maximum of two I/O cards may be added to the PXM3000 meter.PXM1K-1XX• 6x digital inputs• 24 Vdc power for digital inputs •2x relay outputsPXM1K-2XX• 4x digital inputs • 2x digital outputs •2x analog outputsPXM1K-3XX• 4x digital inputs • 2x relay outputs •2x analog inputsPanel mount remote displayPXM 3000 panel mount remote display (PXM3K-DISP) for DIN rail mount transducer version (eg. PXM3000TA15). The remote displayincludes 6ft cable for the connection.7Technical Data TD0262032ENEffective January 2022Power Xpert Meter 3000 Series EATON Meter input wiringFigure 2. Three-phase, four-wire (3LN, 3CT).Figure 3. Three-phase, three-wire (3LL, 3CT).Figure 4. Three-phase, four-wire with PT (3LN, 3CT).Figure 5. Three-phase, three-wire with PT and 2CT (2LL, 3CT).Figure 6. Single-phase, three-wire (1LL, 2CT).Figure 7. Single-phase, two-wire (1LN, 1CT).* 1A fuse typical8Technical Data TD0262032ENEffective January 2022Power Xpert Meter 3000 SeriesEATON I/O cards wiringDI1DI2DI3DI4DI5DI6DIC RO1RO2ROC V+ V- Digital InputDigital OutputVdc++––QF1QF2QF3QF4QF5QF6Figure 8. PXM1K-X1XFigure 9. PXM1K-X2X/X3XDimensions in inches (mm)Figure 10. PXM 3000Figure 11. DIN mount meterFigure 12. External display moduleFigure 13. I/O moduleDigital Input+QF1QF2QF3QF4QF5–20–160 Vac/dcDI1DI2DI3DI4DIC9Technical Data TD0262032ENEffective January 2022Power Xpert Meter 3000 Series EATON Ordering informationTo order a Power Xpert Meter 3000, the catalog number should be determined using T able 1. The table illustrates how to includethe desired factory options as part of a catalog number. I/O option modules are separate and field installable. Each type of I/O module also has two addresses, logic address 1 and logic address 2. Up to 2 I/O modules per meter can be installed. Power Xpert Meter modules include panel mounting brackets.Example: PXM3000MA15 (PXM 3000 meter/display, 5 A, 100–277 Vac or 100–250 Vdc)T able 1. Power Xpert Meter 3000 catalog numbering system.PXM 3000 M A 1 5Meter series3000 = Rich web interface, data logging. waveform capture, TOU, PQ logging, eth-ernet and Modbus RTU.Meter typeM = Meter (with integral display)T = Transducer only (no display)Power supply1 = 100–277 Vac or 100–250 Vdc 4 = 20–60 VdcCurrent input5 = 5A/1A secondaryT able 2. Power Xpert Meter 1000/3000 I/O module.DescriptionCatalog numberPXM 1000 I/O module logic address 1; 2 RO, 6DI with DI power supply 24 VdcPXM1K-110PXM 1000 I/O module logic address 2; 2 RO, 6DI with DI power supply 24 VdcPXM1K-120PXM 1000 I/O module logic address 1; 4 DI, 2 DO, 2 AO (4–20 mA)PXM1K-210PXM 1000 I/O module logic address 1; 4 DI, 2 DO, 2 AO (0–20 mA)PXM1K-211PXM 1000 I/O module logic address 1; 4 DI, 2 DO, 2 AO (1–5 V)PXM1K-212PXM 1000 I/O module logic address 1; 4 DI, 2 DO, 2 AO (0–5 V)PXM1K-213PXM 1000 I/O module logic address 2; 4 DI, 2 DO, 2 AO (4–20 mA)PXM1K-220PXM 1000 I/O module logic address 2; 4 DI, 2 DO, 2 AO (0–20 mA)PXM1K-221PXM 1000 I/O module logic address 2; 4 DI, 2 DO, 2 AO (1–5 V)PXM1K-222 PXM 1000 I/O module logic address 2; 4 DI, 2 DO, 2 AO (0–5 V)PXM1K-223 PXM 1000 I/O module logic address 1; 4 DI, 2 RO, 2 AI (4–20 mA)PXM1K-310 PXM 1000 I/O module logic address 1; 4 DI, 2 RO, 2 AI (0–20 mA)PXM1K-311 PXM 1000 I/O module logic address 1; 4 DI, 2 RO, 2 AI (1–5 V)PXM1K-312 PXM 1000 I/O module logic address 1; 4 DI, 2 RO, 2 AI (0–5 V)PXM1K-313 PXM 1000 I/O module logic address 2; 4 DI, 2 RO, 2 AI (4–20 mA)PXM1K-320 PXM 1000 I/O module logic address 2; 4 DI, 2 RO, 2 AI (0–20 mA)PXM1K-321 PXM 1000 I/O module logic address 2; 4 DI, 2 RO, 2 AI (1–5 V)PXM1K-322 PXM 1000 I/O module logic address 2; 4 DI, 2 RO, 2 AI (0–5 V)PXM1K-323T able 3. Power Xpert Meter 3000 accessories.DescriptionCatalog numberPXM 3000 panel mount remote display for DIN rail mount transducer version; include one 6 ft cable PXM3K-DISP-3Din rail mounting adapter PXM1K-DINADPT Terminal plug kit PXM1K-TPKDisplay cable (6ft)PXM1K-DISPCBL-6Display cable (15ft)PXM1K-DISPCBL-1510Technical Data TD0262032ENEffective January 2022Power Xpert Meter 3000 SeriesEATON Technical informationRoHSAC/DC control powerOperating range: 100–277 Vac, 50/60 Hz; 100–250 Vdc Burden: 5 WFrequency: 50/60 HzWithstand: 3250 Vac, 50/60 Hz for 1 minute Installation category III (distribution)Low voltage DC control power (optional)Operating range: 20–60 Vdc Burden: 5W11Technical Data TD0262032ENEffective January 2022Power Xpert Meter 3000 Series EATON Notes:Eaton1000 Eaton Boulevard Cleveland, OH 44122 United States © 2022 EatonAll Rights ReservedPrinted in USAPublication No. TD0262032EN / TBG001478 January 2022Eaton is a registered trademark.All other trademarks are propertyof their respective owners.Power Xpert Meter 3000 SeriesTechnical Data TD0262032EN Effective January 2022。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档
最新文档