【刘可】公园景观室外给排水施工图

合集下载

【CAD图纸】公园改造景观施工图-厕所(精美图例)

【CAD图纸】公园改造景观施工图-厕所(精美图例)
给排水平面1:50下-0.150男-0.050下%%p0.000值班室0.100女-0.050 }目工程名称图\P\P名工程负责人审 核审 定图 号制 图校 对设 计设计号(盖章有效) 年 月 日出图章0.100接室外总管-0.45L=3.4M i=0.005=8.1M i=0.005%%C\f仿宋_GB2312|b0|i0|c134|p49%%C\f仿宋_GB2312|b0|i0|c134|p49L=2.7M i=0.005接8#化粪池-0.47-0.51-0.52电气平面图制 图校 对设 计工程名称 }目图\P\P名审 定工程负责人审 核1:50(盖章有效) 年 月 日设计号出图章图 号-0.150下下%%p0.000值班室男-0.050女0.100-0.0500.100FL=5米L=5米接地极 镀锌角钢50*5*2500接地母线40*4 接总配0.9500.9501.1001.1000.3000.3001.1800.9500.750±0.000-0.550De63De50De50De40De40De32De32De40De32De63DN100DN200DN100DN100DN100DN200DN100DN50DN200DN200DN100DN50DN100DN50DN50DN50DN50DN50DN100DN100DN100DN100DN200DN200DN100DN50DN100DN50给水系统图排水系统图\C1\C1\H500图例序号1A86K11-10YG2-2*20WPZ30MX9347-13WA86Z223-10双管日光灯双极暗开关配电箱半圆吸顶灯二三孔插座4523211111型号规格图例名称数量C45N/1PF NS-40-100VV22-5*6-SG40-A电源进线F配电箱BV-3*2.5-PVC15-ABV-3*1.5-PVC15-ABV-3*1.5-PVC15-AC45N/1P16AC45N/1P16AC45N/1PC45N/1P16A10A10A备用插座照明照明 备用C45N/1P10A备用厕所厕所给排水设计厕所厕所电气设计15006500270018002000250035009900390050003500990065002700180020002500150050003900

CAD给排水设计施工图--西湖一村室外给排水工程

CAD给排水设计施工图--西湖一村室外给排水工程
3F农民文化广场1F社区服务配套1#2#3#4#5#6#7#8#9#10#11#12#13#14#15#16#17#19#20#18#21#22#23#24#25#26#27#28#29#30#31#32#33#34#35#36#37#38#39#40#41#42#43#45#46#47#48#49#50#51#52#53#54#55#59#58#57#56#60#61#62#63#64#65#66#67#68#69#70#71#73#72#74#75#76#77#81#82#78#79#83#80#44#污水处理站3F2F1F32.90(%%P0.00)32.90(%%P0.00)32.90(%%P0.00)32.90(%%P0.00)32.90(%%P0.00)32.90(%%P0.00)32.90(%%P0.00)32.80(%%P0.00)32.80(%%P0.00)32.80(%%P0.00)32.80(%%P0.00)32.60(%%P0.00)32.60(%%P0.00)32.60(%%P0.00)32.60(%%P0.00)32.60(%%P0.00)32.60(%%P0.00)32.60(%%P0.00)32.50(%%P0.00)32.50(%%P0.00)32.50(%%P0.00)32.30(%%P0.00)32.30(%%P0.00)32.30(%%P0.00)32.10(%%P0.00)32.10(%%P0.00)32.10(%%P0.00)32.60(%%P0.00)32.60(%%P0.00)32.60(%%P0.00)32.50(%%P0.00)32.50(%%P0.00)32.50(%%P0.00)32.60(%%P0.00)32.30(%%P0.00)32.30(%%P0.00)32.30(%%P0.00)32.30(%%P0.00)32.30(%%P0.

某公园基础设施系统配置给排水设计图

某公园基础设施系统配置给排水设计图
潍河路}沂河路}花\P\P\P\P\P\P\P\P\P\P砖花\P\P\P\P\P\P\P\P\P\P砖花\P\P\P\P\P\P\P\P\P\P砖花\P\P\P\P\P\P\P\P\P\P砖花\P\P\P\P\P\P\P\P\P\P砖花\P\P\P\P\P\P\P\P\P\P砖水上活动区混2厕广播电视局花砖砖砖砖混3水上活动区砖混3株株株62163131株株株87242247高3-3.5米高3-3.5米高3-3.5米高3-3.5米胸径7-8厘米胸径7-8厘米单位单位数量规格124653图例序号名称油松雪松水杉金丝垂柳大叶白蜡小龙柏苗木表株株株724128株株87267株57高1.2-1.5米高1.2-1.5米高1.2-1.5米胸径7-8厘米胸径5-6厘米胸径5-6厘米798121110榆叶梅火炬树元宝枫日本晚樱紫丁香连翘002020101050502公园主要北入口健身广场1233-0.90-0.90下沉广场北一楼南一楼233南三楼喷雾森林2嘹望塔南二楼2432133223223北二楼322南 3 楼222.4022243324332公园入口-0.90科技馆入口4544-0.60车入口4.504.504.004.504.004.482混4.494.614.664.344.304.624.334.554.524.494.474.434.47砖4.224.396.004.464.213.002.993.503.034.31公园主要北入口公园主要北入口o1 oooooo234567垂钓园区孙武广场采摘果园原有苗圃高尔夫球练习场九曲花溪黑松林采摘果园采摘果园6米构架柱式保持原有铺装上上上上上上坡道坡道水上活动区观景廊独立树坛6~7棵雪松树丛5号化粪池5号化粪池324DN400-0.2-0.2-0.2接入南一路雨水井DN400-0.2-0.2-0.2接入南一路雨水井DN400-0.2-0.2-0.2DN

室外给排水系统识图及施工

室外给排水系统识图及施工

(2)试验管段所有敞口应封闭,不得有渗漏水现象;试验 管段不得用闸阀做堵板,不得含有消火栓、水锤消除器、 安全阀等附件;水压试验前应清除管道内的杂物。试压之 前,在管身上回填一定的土方量来保证管道的稳定性,接 口位置不允许回填以便检查渗漏处。
(3)试验管段注满水后,宜在不大于工作压力条件下充分
浸泡,再进行水压试验,试验压力如表2-1所示。
混合槽:适用于土层不均匀,如上层软下层硬,或挖深较大,完 全用梯形槽不经济时,上部采用梯形槽,下部直槽或上部边坡较 缓,下部边坡较陡。
联合槽:适用于数条管道位置很近而埋深不同,数条管道需在同 一沟槽中埋设时采用此种形式。
科学出版社
室外给排水系统识图及施工
图 2-10沟槽断面形式 a-直槽;b-梯形槽;c-混合槽;d-联合槽
科学出版社
室外给排水系统识图及施工
图2-14 垂直支撑
图2-15 钢板桩
科学出版社
室外给排水系统识图及施工
(6)锚锭式支撑 锚桩必须设置在土的破坏范围以外,拉杆一般水 平放置,通过开沟浅埋地表下,整个围护系统在 基坑开挖之前完成。如图2-16所示。 (7)土钉墙 土钉墙是采用土钉加固的基坑侧壁土体与护面等 组成的结构。它是将拉筋插入土体内部全长度与 土粘结,并在坡面上喷射混凝土,从而形成加筋 土体加固区带,增强基坑边坡坡体的自身稳定性。 如图2-17所示。
科学出版社
室外给排水系统识图及施工
5.给水管道的试压。给水管道的压力试验,如无设计要求, 应符合下列规定:
(1)水压试验的管段长度一般不超过1000m;应在管件支 墩做完,并达到要求强度后作压力试验,对未做支墩的管 件应做临时后背;埋地管道,须在管基检查合格,管身上 部回填土不小于500mm后,方可作压力试验。如图2-18所 示。

景观给排水施工方法

景观给排水施工方法

景观给排水施工方法说实话景观给排水施工这事儿,我一开始也是瞎摸索。

经过这么长时间的捣鼓,也算是有点自己的经验了。

先说说排水这块儿吧。

下管的时候可真得小心,我第一次弄的时候就毛手毛脚的。

就像给人穿针线似的,你要是不仔细,那管子就很容易歪或者磕破了。

我当时想着这有啥难的呢,一扔一放就完事儿,结果发现管子接口就对不上了。

所以啊,放管的时候得慢,特别是那种比较大口径的管子,要慢慢调整角度,让它跟事先挖好的沟是顺顺当当的。

然后是接口,这个我吃过亏的。

接口密封不好,水就会渗出来。

我试过各种密封材料,什么胶泥啊、橡胶圈啊。

就拿胶泥来说,涂的时候不能太薄,薄了就像纸糊的窗户,一捅就破,水轻轻一挤就漏出去了;但也不能涂得太厚,浪费材料不说,还可能把管子接口弄得鼓鼓囊囊的不平整。

我后来总结出来,按照说明书上那个标准量来涂,然后再用工具把它捋得严严实实的才靠谱。

还有挖排水坡度,这可太重要了。

这就好比水在滑梯上往下滑,你要是滑梯太平了,水就下不去。

我之前没太注意这个坡度,结果积水了,搞得那一块地方都泥泞不堪。

后来就拿个水平仪,一点点量,算好坡度,再让挖土机师傅照着做。

只不过这计算坡度有时候会出错,毕竟咱不是专业的测量员,但是大致的方向没错就好。

要是感觉不太准,就做小一点的坡度,多几个排水口,这样虽然麻烦点,但起码水能够排得出去。

说到给水,就不能马虎管材质量。

我有一次贪便宜买了些不太知名杂牌的管材。

施工的时候,稍微一用力,那管子就有裂缝了。

就像那种不结实的饼干,一捏就碎。

后来学乖了,看管材就看品牌、看厚度、看有没有相关合格证明。

安装的时候,要固定牢,就像搭积木一样,你得让它稳稳当当站在那,不然一运转起来里面水一动,管子晃来晃去容易损坏。

关于景观给排水施工,每个工地的情况都不完全一样,所以这些方法也得根据实际情况慢慢调整。

但是我这些经验呢,希望能给大家起到一点帮助作用,至少能够少走点我之前走过的弯路。

有的时候别小瞧了任何一个小环节,往往小问题会引发大麻烦,我就是在这些教训里慢慢成长起来的。

室外工程设计图纸--给排水(2019.12.25)

室外工程设计图纸--给排水(2019.12.25)
水水3.263.192.433.753.743.202.272.812.663.172.933.062.473.003.543.743.653.523.243.372.652.913.223.565.125.194.124.154.144.714.694.674.234.324.035.165.075.175.133.985.125.145.135.135.134.944.124.454.333.873.733.203.053.002.992.993.043.123.024.784.204.413.082.702.983.163.083.183.123.112.963.043.093.603.104.023.043.193.022.943.183.273.043.433.212.952.843.073.163.113.393.053.522.983.062.974.013.052.953.983.943.944.423.554.274.374.023.923.853.914.444.194.244.534.434.504.394.434.554.564.554.554.515.474.544.394.384.604.594.534.574.564.584.534.544.614.534.564.534.544.524.584.524.534.564.554.544.564.474.484.434.254.234.364.344.474.094.144.324.404.224.114.464.414.534.534.374.534.314.324.234.214.164.254.144.114.304.554.334.314.264.224.194.10T0244.91混混混混42砖砖砖地砖地砖地砖草砖地砖水泥施工水泥水泥水泥水泥碎石水泥水泥花坛花坛上下上1:5000.30m3.95m6.806.800.30m路路南环女生宿舍扩建宿舍男生宿舍师生食堂停车场传达室主出入口连廊行政图书馆实验楼连廊教学楼400标准田径场休闲广场2F5F5F5F风雨操场教师办公室足球场400标准田径场台阶改造区域台阶改造区域台阶改造区域台阶改造区域台阶改造区域台阶改造区域台阶改造区域门牌R9.00R9.00R9.00篮球场外2.002.001.400.300.303.503.506.701.251.250.600.300.301.630.300.303.606.702.002.004.504.504.300.300.3012.700.300.309.5928.330.302.600.301.500.300.303.950.301.500.302.600.302.502.502.502.502.502.500.250.251.003.500.600.300.303.901.400.300.302F4F4F新建建筑物图例:道路围墙线已建建筑物3F水水T0244.91混混混混42砖砖砖水泥碎石水泥水泥1:5000.30m3.95m6.806.800.30m路路南环女生宿舍扩建宿舍男生宿舍师生食堂停车场传达室主出入口连廊行政图书馆实验楼连廊教学楼400标准田径场休闲广场2F5F5F5F风雨操场教师办公室足球场400标准田径场台阶改造区域台阶改造区域台阶改造区域台阶改造区域台阶改造区域台阶改造区域台阶改造区域门牌R9.00R9.00R9.00篮球场外2.002.001.400.300.303.503.506.701.251.250.600.300.301.630.300.303.606.702.002.004.504.504.300.300.3012.700.300.309.5928.330.302.600.301.500.300.303.950.301.500.302.600.302.502.502.502.502.502.500.250.251.003.500.600.300.303.901.400.300.302F4F4F新建建筑物图例:道路围墙线已建建筑物3FDN300-10-4DN300-17.8-4DN300-17.8-4DN300-20-3DN300-24.7-3DN300-11.2-3DN300-24-3JX生活低压给水管室外消防给水管(室内外合用管网)接室内给水管网接室外自来水管网低阻力倒流防止器水表安装参考图集05S502-P42地上式消火栓 SS100/65-1.0 共1组加筋UPVC管,埋地消防管采用钢丝网骨架塑料复合管,电熔连接。室内给水管采用PP-R管,热熔连接;室内消防管采用内外热镀锌钢管,螺纹接口。其中明露钢管刷银粉漆两道,埋地2、管材及防腐--室外埋地给水管采用PE管 ;室外检查井间连接的排水管采用说明:室内外消防给水管网由水泵加压提供。1、本工程单体室外最大消防用水量为25L/S,单体室内最大消防用水量为15L/S,3、管道敷设--室外给水及消防管在车行道下管道埋深为900mm以上,其余地方埋深 为700mm以上。如与排水管道交叉,应按有关规范作避让处理。壁需刷红漆作为消防标志色。钢管做两布三油防腐,镀锌层破坏 处尚需刷樟丹油一道防腐。另外,室内外明装消防管外4、施工前复核与城市给水管网接口处的具体位置、管径和标高,如无法接口,应及时 与设计人员联系。排水管道基础、施工可参见《埋地塑料排水管道施工》(04S520),汽车库顶板上排水管道埋深5、雨水蓖采用DN200接附近雨水干管。7、室外消防管道工作压力0.6MPa,试验压力0.90MPa;给水及消防管施工完成后,应逐段进行水6、参考图集: 雨水检查井:接管 DN≤400时, d700 圆形砖砌雨水检查井 02S515-10雨水蓖见 95S518-2 化粪池参考 02S701 接管 DN=400~600时, d1000 圆形砖砌雨水检查井(盖板式) 02S515-12 污水检查井:接管 DN≤400时, d700 圆形砖砌污水检查井 02S515-19 室外地上式消火栓安装详《01S201-6》;达不到要求的地方需做加固处理.阀门井详见国标05S502, 水表井详见国标05S502室外消火栓详见国标13S201, 水泵接合器见国标99S203P11.压试验,试验合格后方可交付使用。管道试压具体要求:-2008)第10.2.10条及第10.2.13条之规定进行,试验压力为0.9MPa。室外给水管道试验应按《给水排水管道工程施工及验收规范》(GB50268给水管道试压合格交付使用前,应按《给水排水管道工程施工及验收规范》(GB50268-2008)第10.4.1条及10.4.4.条的要求,对管道进行冲洗消毒.室外排水管的试水要求,应按《给水排水管道工程施工及验收规范》(GB50268-2008)第10.3.1条及第10.3.6条之规定进行。3.1.2.序号说明图例备注123图例:管径-管长-坡度‰污水管及检查井雨水管及检查井管径-管长-坡度‰雨水口WY检查(沉砂)井防护(坠)网安装平面图 1:20∅625∅525%%C10尼龙绳与铸铁井座环焊接相连镀锌钢钩%%C10,L=60适用于沥青混合料路面2,3042,304注:\P1、本图以毫米为单位。\P2、安装井盖设施时,井盖设施不能有任何凸起或下陷,其顶面标高须与路面标高一致。\P3、检查(沉砂)井防护(坠)网由护网、固定圈、挂钩三部分组成。井挂网用材及安装方法必须满足150KG重物从1米高处堕落,挂网能够有足够的强度支撑。\P(1)护网与固定圈选用1cm尼龙材料制成的尼龙绳。护网由若干条1cm尼龙绳编织而成,呈蜘蛛网状,连接在固定圈上。固定圈由1cm的尼龙绳制成。与检查井内壁通过8个平均分布的钢钩连接。\P 严禁使用有断绳等已损坏的护(坠)网。\P 护(坠)网安装完成后需要对其进行坠落测试,参见<<绳索有关物理和机械性能的测定>>(GB/T 8834-2006),测试合格后方可验收。\P(2)挂钩做法:\P 挂钩与铸铁井座环焊接相连。\P 所有构件的焊接加工必须满足国家行业标准<<建筑钢结构焊接技术规程>>(JGJ81-2002)的技术要求。\P 焊接需平整、满焊,焊缝不得有气孔、夹渣和未焊透等缺陷.焊口应打磨平整,表面不得有裂缝,成型均匀、圆滑。漆膜应平滑,不得有流挂或起泡现象。\P 焊接成型后须进行除锈、热镀锌处理,镀锌量为600g/m2,镀锌后表面烘喷黄黑色相间的面漆。\P4、检查(沉砂)井防护(坠)网应定期检修,护网应每两年更换一次。\P5、其余未尽事宜均按照<<城镇排水管道维护安全技术规程>>\P(CJJ 6-2009)等相关规定施工和验收。}可调式井盖和防护(坠)网安装剖面图 1:20预制砼调节环%%C625X50(100)防护(坠)网填充面层沥青混合料与铸铁井座环焊接相连镀锌钢钩%%C10,L=60检查(沉砂)井井体适用于沥青混合料路面720球墨铸铁可调式防沉降井盖设施地下消防水池净容量300吨泵房1F发电间3.505.940.5524.241.769.243.126.1218T水箱屋顶(已建)(已建)(已建)(已建)(已建)(已建)(已建)地下消防水池净容量300吨泵房1F发电间3.505.940.5524.241.769.243.126.1218T水箱屋顶北总给水平面图1:100%%P0.00(4.35)DN65DN65JJ就近接至园区生活给水管网DN150DN150DN150DN150DN150DN150北总排水平面图1:100%%P0.00(4.35)就近接至园区道路污水管网XXXXX室外消火栓就近接至园区消防管网DN150就近接至园区消防管网DN150YWWYYYY就近接至园区道路雨水管网就近接至园区道路雨水管网3.0002.9602.8902.8123.0002.9203.0002.9262.8922.820天正单行文字输入消防水池、泵房(待建)屋顶消防水箱(待建)消防水池、泵房(待建)屋顶消防水箱(待建)AAGG1112121/12

【设计图纸】风景区景观建设-农居山村给排水(精美CAD图例)

【设计图纸】风景区景观建设-农居山村给排水(精美CAD图例)
民民宿村庄管理中心苗圃露天茶坊民俗作坊水杉树林竹林别墅型农居土地庙出口院落型农居农居饭庄小卖部别墅型农居院落型农居院落型农居院落型农居别墅型农居别墅型农居商店院落型农居别墅型农居农居山村给排水平面图0261020M厨房男厕所女厕所餐厅大厅会议室办公室办公室值班室大厅厕所大厅客房过道客房大厅客房客房浴室浴室大厅大厅客房浴室客房大厅厕所大厅男道客房大厅客房客房浴室浴室厕所客房客房大厅客房厕所客房厕所客房厕所仓库小厅小厅小厅小厅餐厅小厅小厅小厅小厅大厅厨房过道茶楼小展厅大展厅储藏室化成洞景区详细规划污水排放农田水井化粪池给水管道均为DN100排水管道化粪池前为DN200,化粪池后为DN300注:2000.JD.031电 气建 筑结 构给 排 水暖 通总 图设计 计算审 定专业负责人审 核总负责人复 核校 对制 图项 目图 名浙江佳境规划建筑设计研究院证书等级: 甲 级证书编号: 1201261工 程 名 称设计号图 号农居山村给排水平面图瑞安市仙岩风景名胜区化成洞景区详规设计方案图例给水管道排水管道消防栓N

某地两层框架结构体育公园给排水施工图

某地两层框架结构体育公园给排水施工图
N建 筑电 气给 排 水结 构暖 通海口市城市规划设计研究院景和建筑设计顾问有限公司规划与建筑方案设计甲级证书编号:211107-sj建设单位工程名称图纸内容日 期图 号图 别比 例工程编号项目负责人设 计校 核审 核审 定接市政给水管网M1M11F1F2F2F2F2F1F%%P0.000H+2.100H+0.900HƐH+0.900H+1.000H+1.150H+0.350感应式冲洗阀H+1.3001F%%P0.0001F1F1F1F1F1F1F1F1F1F1F1F2F2F2F1F2F1F1F2F1F1FXL-18XL-18接消防水箱消防出水管详见04S202-16屋面试水栓DN125沿梁底敷设沿梁底敷设沿梁底敷设沿梁底敷设埋地敷设埋地敷设埋地敷设看台顶沿地面敷设沿地面敷设埋地敷设埋地敷设看台顶+1.100余同看台顶XL-1XL-2XL-3XL-4XL-5XL-6XL-7XL-8XL-9XL-10XL-12XL-13XL-15XL-16XL-17XL-19接消防加压泵出水管RFQ=20L/SDN125DN125DN125DN125DN100DN100DN100DN125DN125DN125DN125DN125DN125DN125DN125DN125DN125埋地敷设埋地敷设埋地敷设埋地敷设沿地面敷设沿地面敷设1F1F1F1F1F埋地敷设埋地敷设DN65DN65DN65DN65DN65DN65DN65H+1.150H+0.900H+1.000H+0.900H+1.000接至1#更衣室吊顶内敷设接至一层女卫生间接至2#更衣室预留管接至一层厨房2F沿吊顶内敷设H+0.3501F2FH+0.3502FH+0.900H+1.000H+2.100H
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档
最新文档