FMX-003静电场测试仪中文使用说明(1)

合集下载

静电测试仪

静电测试仪

SIMCO FMX-003静电场测试仪产品介绍:SIMCO"FMX-003"新一代静电场测量表,在原"FMX-002"表基础上添加更多新的技术元素!!!FMX-003是一非接触式手提静电场测试仪。

可测范围在+/-20KV(工作距离为1英寸,25mm)配置有2个LED 灯确保测量时离被测物体保持25mm。

外壳为防静电材质,并有接地扣,确保测量结果可靠。

该测试仪还附有可配离子平衡测量板,用于对±200V范围内的离子平衡度作周期性校验。

SIMCO FMX-003静电场测试仪产品图片:SIMCO FMX-003静电场测试仪产品特点:1:电池(4档)效能显示2:条型图显示电性强弱3:自动控制型数字显示4:多功能报警提示5:闲置5分钟后自动关机6:配离子平衡测量板7:附有LED照明,也可在暗处读数据。

8:传感器故障时,Err表示。

9:配有包装盒,接地扣,电池。

SIMCO FMX-003静电场测试仪产品使用说明:单按归零重置单按显示锁定闲置自动关机电池效能显示功能:有效检测ESD工作场所设备,工作台面,工具的带静电电荷。

特性:液晶/电平显示检测数据,测试数据保持,数字清零显示,高/低档量程。

输出:红色LCD显示正电荷、蓝色LCD显示负电荷精度:低范围精度为:正负0.1kv 高范围精度为:正负1kv输入电压:9V,6F22 镍电池静电场可测:+/-(0.00-20.0kV)(自动显示调整)标准测距:25mm+/-1mm离子平衡可测:+/-(0-200V)测量距离根据:ESD-STM3.1-2000 离子平衡标准LCD显示更新:每秒5次反应时间:1秒工作温湿度:10-40 deg C/RH:0-60%R图形显示:正:红色/ 负:蓝色声响报警:开机/闲置自动关机/超出可测范围自动关机:闲置约5分钟测量模式切换静电场:单按Power键,有一嘟声离子平衡(请先安装离子平衡测量板)同时按Zero和Power,有二嘟声SIMCO FMX-003静电场测试仪产品规格:SIMCO FMX-003静电场测试仪产品分解图:SIMCO FMX-003静电场测试仪产品特点:1:电池(4档)效能显示2:条型图显示电场极性及强弱3:自控量程数字显示4:多功能报警提示5:闲置5分钟后自动关机6:可配离子平衡测量板7:附有LED照明,也可在暗处读数据。

防静电专用测试仪使用操作指导书

防静电专用测试仪使用操作指导书

****有限公司工作指令文件修改记录表编号:SF008 0次修改保存期限:新版发行后1个月****有限公司部门工作指令文件编号 : WI.PNNPI.003页数:共 11 页版本号:第 C 版修改次数:第 0 次修改防静电专用测试仪使用操作指导书制订:审核:批准:生效日期:WI.PNNPI.003目录1. 目的2. 适用范围3. 职责4. 相关文件5 仪器使用指导5.1. 接地阻抗分析仪61-164CN的使用5.1.1设备功能简介、面板使用和其它。

5.1.2.电源插座地线测试步骤5.1.3.辅助地线测试步骤(这里指独立的防静电地线的测试).5.2 静电电压测试仪MODEL 520的使用5.2.1设备功能简介、面板使用和其它。

5.2.2静电电压测试步骤.5.3. 兆欧表MODEL 152的使用5.3.1设备功能简介、面板使用和其它。

5.3.2.表面点对点电阻测试步骤.5.3.3.表面点对地电阻测试步骤.5.3.4.体积电阻测试步骤5.4. 静电消除测试仪MODEL 156A使用。

5.4.1设备功能简介、面板使用和其它。

5.4.2. 静电消除测试仪MODEL 156A测试离子风机参数设置步骤。

5.4.3.静电消除测试仪MODEL 156A测试离子风机静电性能步骤。

5.5. 静电消除测试仪MODEL 158使用。

5.5.1设备功能简介、面板使用和其它。

5.5.2. 静电消除测试仪MODEL 158测试离子风机参数设置步骤。

5.5.3. 静电消除测试仪MODEL 158测试离子风机静电性能步骤。

5.6屏蔽袋测试仪ACL500的使用5.6.1设备功能简介、面板使用和其它5.6.2 . 屏蔽袋屏蔽性能测试步骤。

1. 目的规范接地阻抗分析仪61-164CN、静电电压测试仪MODEL 520、兆欧表MODEL 152、静电消除测试仪MODEL 156A、静电消除测试仪MODEL 1568、屏蔽袋测试仪ACL500等专用仪表的使用,以确保操作人员能正确操作相应测试设备。

FMX003静电测试器中文操作手册

FMX003静电测试器中文操作手册

SIMCO FMX-003 靜電測試器中文操作說明光鼎儀器有限公司PARA LIGHT INSTUMENTS CO LTD總公司:330桃園市寶慶路514號3樓TEL:03-3027863 FAX:03-3023252台中分公司:台中市西屯區國安一路145號3樓之1TEL:04-2463-1120 FAX:04-24631123高雄分公司:高雄市明華路330號6樓TEL:07-5538707 FAX:07-5538221.乾電池更換方式FMX-003所附的電池使用壽命約30小時,電池殘存電量如右圖所示電池更換順序1.機身背面有一各電池蓋,將電池蓋上(OPEN)字樣的地方下壓並往外推即可打開電池蓋2.取出電池,並從連接線上將電池拆除3.將新電池連接上,並注意極性方向4.將電池附入機身內5.將電池蓋朝機身方向推入卡緊,即完成電池更換動作6.靜電電位測量FMX-003表面有4顆按鈕,功能如下:[POWER] (紅色圓圈) 電源開關[IB] (藍色圓圈) 離子平衡模式開關[HOLD] (綠色開關) 暫停開關[ZERO] (灰色開關) 數值歸零開關(歸零調整)6.1接地連接FMX-003進行靜電測量時,除了因測量者本身帶電影響測量精度外,也會因圍工作人員或物體的帶電而影響測量結果.為了進行準確的量測,FMX-003的操作測量員為避免帶電而採取接地措施(接地腕帶等),或者是利用主機右側的接地端子與專用的接地線連接,以達到確實接地動作6.2測定模式設定6.2.1 靜電電位測量模式1.在無帶電空間裡,按下印有[POWER]字樣的紅色按鈕,之後會聽到一次的[嗶]聲響起(0.25秒),即表示進入靜電測量模式.2.電源開啟時,螢幕上會有數值,單位顯示(kV),極性,條圖及電池殘量顯示,此時請確認電池殘存容量,電源開啟時,主機前端兩個LED燈會亮起,表示可進行量测動作.3.開機狀態下,5分鐘內無任何操作動作將會進入自動關機模式,此時會有兩聲[嗶嗶]音響起,間隔約1秒鐘,之後電源將會切斷4.開機狀態下,再按壓一次[POWER]鍵會關機,所有螢幕顯示都會消失.6.2.2 靜電連續測試模式1.接通電源後,在無帶電空間中[power]鍵連續壓放,右上角的條圖顯示會每隔一秒顯示一格,顯示3格條圖後,放開[power]鍵會響起3聲(嗶)聲,此時進入連續量測模式,自動關機功能也會被取消.2.電源開啟後,畫面會顯示數值,單位,極性,條圖,電池殘量指示及[A.OFF]連續測試,請確定電池電量是否充足及主機上方測試環燈是否點亮3.為了避免電池電力浪費,LED對焦環於1分鐘後自動關閉,如需電量對焦燈,請先按壓[HOLD]鍵開啟HOLD功能,然後再按壓一次[HOLD]鍵解除該功能,1分鐘後對焦燈會再亮起,也可選擇按壓[ZERO]鍵進行上述動作,一樣可開啟對焦燈4.測試結束後,按壓[POWER]關機6.3歸零調整主機畫面數值顯示[0.00]以外的場合時,在無帶電空間中,按壓灰色[ZERO]字樣的按鍵一次,即可將數值歸零,畫面顯示變為[0.00]即可測量6.4靜電量測測量時請盡量靠近被測物體, 對焦燈重疊之距離為最佳量測距離6.5暫停功能測量中按壓綠色[HOLD]鍵,可將數值暫停,主機畫面左方會顯示[HOLD],且對焦燈會熄滅,再按壓一次該鍵可取消暫停功能,恢復測量狀態7.離子平衡測量透過離子平衡測量板,可以快速測量各種靜電消除裝置的離子平衡狀態7.1離子平衡測量板安裝方式按壓主機下方兩側按鈕,取出下方的測量板,將測量板安裝於主機上方並稍微下壓至卡榫卡緊為止.待測量結束後,依上述方式將其取下裝回主機下方7.2接地連接離子測量模式,可測量最高至200V的低電壓,使用專用接地線接於主機右側的接地端子,請注意是否確實接地7.3測量模式的設定7.3.1離子平衡測量模式1.用手指輕觸平衡測試板消除該板上電荷,之後按壓[POWER]鍵,進入一般測量模式2.再按壓藍色[IB]鍵進入平衡測量模式, 螢幕上會有數值,單位顯示(kV),極性,條圖,電池殘量顯示及[IB]顯示符號,即可開始測量3.開機狀態下,5分鐘內無任何操作動作將會進入自動關機模式,此時會有兩聲[嗶嗶]音響起,間隔約1秒鐘,之後電源醬會切斷4.開機狀態下,再按壓一次[POWER]鍵會關機,所有螢幕顯示都會消失.7.3.2 離子平衡連續測量模式1. 用手指輕觸平衡測試板消除該板上電荷,之後按壓[power]鍵連續壓放,右上角的條圖顯示會每隔一秒顯示一格,顯示3格條圖後,放開[power]鍵會響起3聲(嗶)聲,此時進入連續量測模式,自動關機功能也會被取消2.接著按壓[IB]鍵畫面會顯示數值,單位顯示(V),極性,條圖,電池殘量指示及[IB] 和[A.OFF] ,即可連續測試3.測試結束後,按壓[POWER]關機7.4歸零調整主機畫面數值顯示[0.00]以外的場合時,在無帶電空間中,按壓灰色[ZERO]字樣的按鍵一次,即可將數值歸零,畫面顯示變為[0.00]即可測量7.5離子平衡測量測量時請盡量靠近被測物體,主機畫面會顯示數值及條圖比例7.6暫停功能測量中按壓綠色[HOLD]鍵,可將數值暫停,主機畫面左方會顯示[HOLD],且對焦燈會熄滅再按壓一次該鍵可取消暫停功能,恢復測量狀態. ..。

ESD工具(静电场强度测试仪)使用手册.

ESD工具(静电场强度测试仪)使用手册.

一、仪表介绍
电源开关定位光圈输出端
二、使用方法
1、打开测试仪的电源开关,LCD上显示一个零点几千伏的读数;
2、打开电源开关的同时,仪器的前端会发出两个光圈,如图1;
3、前后移动仪器,将光圈重合在待测物体的表面,这时仪表的读数就是被测物的表面静电压。

如图2。

静电场强度测试仪1
2
图1
图2
三、离子风机新购设备的验收及使用中的定期检测方法
新购设备测试:偏移电压(offset voltage):在置于离子化环境中的CPM的充电平板上观测到的残留电压,小于±35V为合格。

衰减时间(decay time):在置于离子化环境中的CPM的充电平板上的电压由±1000V变化到±100所用的时间,td≤10s为合格。

使用当中的离子化设备用以下方法每季度检测一次其有效性:
A、准备好OHP纸,使用OHP纸摩擦OHP纸,摩擦使之带电,对带电的OHP纸进行电位测试,希望带电量在±0.5 KV 以上。

B 、将带电的OHP 纸,放在离子风机有效范围内,放置2-3秒钟,再对进行OHP 电位测试, 电压
C、使用SIMCO FMX003多功能静电电压测量仪,安装专用充离子平衡测量板后,置于离子化设备作用的工作区(离子风机一般距离为30~100CM)开机状态下记录其电压值,该指标每季度测量一次。

测量结果记录在《静电消除设备--定期检测记录表》中
压,。

静电实验讲稿

静电实验讲稿

实验一静电压的测量一.实验目的1.了解非接触仪表测量静电压的原理。

2.掌握非接触仪表测量静电压的方法二.实验原理非接触式仪表的测量原理是基于静电感应或空气电离。

前者是将仪器置于带电体附近,直接测量其表面电位(实际上,是对带电体表面电场的测量)。

三.实验仪器1.实验仪器SIMCO FMX-003 Electrostatic Fieldmeter (静电场测量仪)2.仪器说明FMX003 静电场测量仪上有四个按掣:ZERO——调整零点HOLD——冻结IB——转换POWER——电源开关四.实验内容测量四种介质的在一定环境下的表面静电压。

五.实验步骤1. 进行测量前,应把FMX003 向着没有静电场的方向或指向天空。

按下红色的电源(POWER)按掣,此时会有一声“Beep”响,指出FMX003 在静电场测量模式,FMX003 前端两盏红色LED灯会亮起,同时显示板会显示电池状况。

这时,显示结果应为0 V,并且没有图形显示出现。

若果不是,请按下灰色的返零(ZERO)按掣,把背景结果归零。

2. 当测量时,把FMX003 向着测量对象,逐渐把FMX003 靠近,直至两盏红色LED 灯的投影重叠(即在标准测距25mm 左右),这时,显示板会显示测量的数值和图形。

(注意:在靠近测量对象中,若数值超出可测范围,则会响起连续的“Beep”声,显示数值会闪动。

这时,应停止测量,否则会损坏内置的感应器。

)3. 若把绿色的冻结显示(HOLD)按掣按下,红色LED 灯会关掉,显示板上的“HOLD”字出现,显示结果已冻结,方便移离测量对象作记录。

再按下绿色的冻结显示(HOLD)按掣,可解除冻结显示状态。

(注意:在“HOLD”状态下,返零(ZERO)按掣不会有效。

)4. 在低电荷量(少于1.49kV)时,每一单位为0.1kV(100V),在高电荷量(1.0kV-20.0kV)时,每一单位为1kV(1000V).5. 再次按下红色的电源(POWER)按掣,会关掉FMX003。

FMX-003静电场测试仪_操作步骤

FMX-003静电场测试仪_操作步骤

Simco FMX-003型静电场测量试仪使用说明在静电电压测量过程中,离子平衡盘一般放在底部端上(与感应器相反的一端)。

而在离子平衡测量中,它应该安装在有感应器的顶端。

第六节静电测量FMX-003 有四个按钮可以运行许多功能. 按钮颜色命名功能按钮颜色名称功能POWER 红电源开关电源开关,白色LED使显示更加明亮及电源自动关闭功能IB 蓝离子平衡模式开关转换模式到离子平衡测量HOLD 绿保持开关保持测量值及图表栏ZERO 灰数字归零开关调节显示到零6.1接地如果FMX-003没有可靠的接地,那么它的精度可能被测量人员身上的静电影响。

对于正确的测量,操作员应该配带一根防静电腕带或FMX-003应该用提供的接地线插入右侧的接地口正确的接地。

(注意:FMX-003的外壳是用导电性的树脂做成的。

接地端口给电路提供一个零电压参考。

这个端口必须可靠的接地才能可靠的测量。

如果没有可靠的接地,那么它的精度是没有保障的。

)6.2 测量模态的选择无论自动关闭功能是否开启,有两种操作模式可以使用:标准模式测量静电(电压)和连续模式进行静电(电压)测量。

6.2.1 标准模式测量静电(电压)①将FMX-003的感应器朝向没有静电的地方,快速按一下标有POWER的按键量。

一声哔哔声(0.25 秒)声将会听到提示FMX-003进入标准测量模式。

②当电源被打开,LCD屏幕显示数值、极性、测量单位:“KV”、曲线图刻度、电池电量状况。

此时,请参照第五节电池的状况所描述确认电池的状态。

感应器旁边的两个红色的LED灯点亮,表示FMX-003已经准备进行静电测量.③电源打开五分钟后,FMX-003将会自动关闭,这就叫做自动关闭功能。

此时,每秒二声哔哔声连续五次提示FMX-003将会很快被关闭.④当电源是打开的时候,如果按POWER键,FMX-003将会关闭所有指示消失.(注意:1、FMX-003轻轻按POWER键就能开机,没有需要重复地按它,频繁的没有必要的开关机操作,或者用指甲按它可能会影响开关的寿命和损坏印刷薄膜。

静电测试仪 SIMCO FMX003说明书

静电测试仪 SIMCO FMX003说明书

SIMCO FMX003Electrostatic Fieldmeter使用手册Rev: HK-021126-1SIMCO FMX-003SIMCO FMX003静电场测量仪,以非接触式方式,透过测量目标表面的静电位,来表示在其上的静电荷量。

它可附加配件,测量离子产生器的离子平衡。

Section 1:简介Section 2:特色Section 3:规格Section 4:安全使用守则Section 5:安装指引Section 6:操作指引Section 7:保养指引Section 8:可更换部件一览Section 9:保证World Leader in Static Conlrol? Since 1936 (ISO9001 Cortified) Page 1 of 8Section 1:简介SIMCO FMX003静电测量仪,以非接触式方式,透过测量目标表面的等静电位,来表示在其上的静电荷量。

它十分轻巧,精确。

易携和易用。

它内置微控处理器,可简单地按红色的电源(POWER)按掣开关,按灰色的返零(ZERO)按掣调整零点,更按绿色的冻结显示(HOLD)按掣。

方便在难以观看显示结果的测量点时,冻结显示后取出再记录。

转换(IB)按掣方便测量操作。

利用两盏LED灯的对焦点,精确地决定测量距离为25mm,并准确地测量该距离的静电电位值,以表示在目标表面上的静电荷,它的测量范围是+/-20kv。

它的外壳是导电材质,若再接上接地线,则能确保测量结果的有效性。

SIMCO FMX003静电测量仪,亦可配上离子平衡测量板,以评估离子产生器的离子平衡Section 2:特色●SIMCO FMX003可测范围在 +/-20 kV.●置有2 LED灯确保测量距离在标准25mm处.●外壳为导电材质, 并有接地扣, 确保测量结果正确可靠.●显示有数字和图形, 清晰明确. 在暗黑环境下, 更可着亮面板显示灯光.●并附有离子平衡测量板, 测量离子产生器的残余电压, 可测范围+/-200V.●电场测量范围+/- 20kV●2 LED 确定25mm工作距离●附有离子平衡测量板 (+/-200V)●单按归零重置●单按显示锁定●闲置自动关机●电池效能显示●面板显示灯光World Leader in Static Conlrol? Since 1936 (ISO9001 Cortified) Page 2 of 8Section 3:规格输入电压9 V battery静电场可测+/-(0.00-20.0kv)(自动显示调整)标准测距25mm +/- 1mm离子平衡可测+/-(0-200V)测量距离根据ESD-STM3。

思美高SIMCO FMX-004静电场测试仪使用说明书

思美高SIMCO FMX-004静电场测试仪使用说明书

思美高SIMCO FMX-004静电场测试仪使用说明书思美高SIMCO FMX-004静电场测试仪使用说明书是一种手持式静电测试仪器,采用先进的震动电容感应技术,使仪器体积小,重量轻。

采用四个按钮结构,操作简便,容易掌握。

本静电测试仪zui大量程为±30KV(30,000)测试结果为2时,显示一条竖条,POWER开/关机;ZERO调仪器归零;MODE为测试模式选择;HOLT按钮锁定读数,并保持测试结果在LCD上。

仪器前端设有两个LED,用来帮助测试人员保持测试仪器跟测试目标之间的距离。

但当测试空气中离子的平衡度时,这两个灯是不亮的。

由于本仪器采用导电材料制作,所以有很强的抗干扰的能力思美高SIMCO FMX-004静电场测试仪使用说明书功能特点:*容易读数,操作简便*轻巧的设计*测试范围宽,重复测试精度高*自动量程转换±30KV(30,000)(距离25mm)*数字和竖条同时显示*五分种自动关机功能*四种测量模式(AUTO(自动),Hi(高量程),Low(低量程),Ionblance (离子平衡))具体参数测范围:0.00--±3.00kV(Low低量程)±0.0--±30.0KV(Hi高量程)0--300V(Ion离子平衡度测试)0—30KV(AUTO自动模式)测量距离:25mm±0.5mm两LED作为测量参考。

距离为仪器到测试目标之间的距离。

响应时间:,<1s测量精度:±10%LCD刷新速度:5次/秒工作条件:10Cº-40Cº,0-60%RH显示特性:两边竖条显示。

蓝的是显示负电,红的显示正电。

竖条显示精度:低测量范围时±0.1KV,高测量范围时±1.5KV,测量离子平衡时±15V。

数显读数:AUTO(自动模式)X.XX=0.00±1.49KV(低量程)XX.X=±1.0KV-±30.0KV(高量程)Hi(高量程)X.X=0.0-±30.0kVLow(低量程) X.XX=0.00-±3.00kV离子平衡模式时显示(IB)XXX=0-±300V模拟电压输出:AUTO ±3.00V(2.0KV=0.2V)HI ±3.00V(1.0KV=0.10V)LOW ±3.00V(2.0KV=0.2V)Ionblance ±3.00V(200KV=2.00V)蜂鸣器响声特点:在下列情况下能听到蜂鸣器响声开机:滴一声响自动关机:无任何操作时五分钟自动关机响三次,每次两声超出测量范围时:发出连续的叫声自动关机功能:本机无操作时,五分钟自动关机,节省电池使用电源:9V方型电池电池寿命:30小时外型尺寸:123(MM)×73(MM)×25(MM)重量:170g思美高SIMCO FMX-004静电场测试仪使用说明书各功能的操作,使用FMX-004使用9V方型电池,电池寿命大概30小时,当机器打开的时候,会有电池电量指示(如下图所示)注*图中黑色部分表示电量电池的更换:1,打开机器后面的电池盖。

SIMCO-fmx003 静电场测试仪用户手册

SIMCO-fmx003 静电场测试仪用户手册
目录………………………………………………………………………… 03 第一节 一般的描述…………………………………………………… 04 第二节 特征…………………………………………………………… 05 第三节 规格…………………………………………………………… 06 第四节 外观…………………………………………………………… 08 第五节 电源…………………………………………………………… 09 第六节 静电荷测量…………………………………………………… 10 第七节 离子平衡测量………………………………………………… 15 第八节 功能表………………………………………………………… 20 第九节 故障解决……………………………………………………… 21
包装项目和配件 (1) FMX-003 静电场测试……………………………………………………1件 (2) 离子平衡盘………………………………………………………………1件 (3) 1m长接地线………………………………………………………………1件 (4) 软皮包……………………………………………………………………1件 (5) 电池 (类型6 F22,9 V)…………………………………………………1件 (6) 操作手册 /证书 (这一本书) …………………………………………1件
FMX-003 的外壳是用导电性的树脂做成的,接地端口给电路提供一个零电压参考。 这个端口必须可靠接地才能可靠的测量。如果没有可靠的接地,那么精度是没有保障的。
6.2 测量模态的选择
无论自动关闭功能是否开启,有两种操作模式可以使用.
6.2.1 标准模式测量静电(电压)
① 将 FMX-003 的感应器朝着没有静电的地方,快速按一下标有POWER的按键量. 一声哔哔声 (0.25 秒) 声将会听到提示 FMX-003 进入标准测量模式。

静电测试仪的使用方法 测试仪是如何工作的

静电测试仪的使用方法 测试仪是如何工作的

静电测试仪的使用方法测试仪是如何工作的静电是一种处于静止状态的电荷,摩擦可产生静电,静电一年四季都会发生。

而在冬季干燥的环境中,静电更简单生。

在生活中,静电普遍存在。

说得认真点,在空气比静电是一种处于静止状态的电荷,摩擦可产生静电,静电一年四季都会发生。

而在冬季干燥的环境中,静电更简单生。

在生活中,静电普遍存在。

说得认真点,在空气比较干燥的冬季,电荷没有适时被中和掉或放掉时,很简单聚积在物体上,这时物体与大地之间有很大的电压,假如用手去靠近带静电的物体,巨大的电势差会击穿空气隙,人体就像一条导线般在该物体与大地之间连上了一条通路,瞬时对地面进行猛烈放电,也就是生活中常说的“被静电刺了一下”。

人们看到的电火花就是巨大电势击穿空气隙形成的瞬时电流通路。

静电测试仪的原理:利用给定的高压电场,对被测试样定时放电,使试样感应静电,从而进行静电电量大小、静电压半衰期、静电残留量的检测,以确定被测试样的静电性能。

功能:有效检测静电放电工作场所设备,工作台面,工具的带静电电荷。

静电测试仪的使用方法:1、在测试仪后的电池槽内放入9V干电池。

2、将接地线香蕉插头插入HAKKO—498测试器上端的接地线插座内。

3、将腕带扎紧手腕。

4、把接地线接到手腕带上。

5、用手按下测试器板。

这时,液晶指示灯亮起并可听到一声鸣声。

(1)若红色“LOW”灯亮,需检查手带与地线的电阻,当小于800千欧,这样会对人体安全有影响。

(2)若红色“HIGH”灯亮,需检查手带是否扎紧手腕,并检查手带接地线电阻,确保手带未松脱测试器接地线。

(3)若绿色“GOOD”灯亮,表示接地系统良好。

—专业分析仪器服务平台,试验室仪器设备交易网,仪器行业专业网络宣扬媒体。

相关热词:等离子清洗机,反应釜,旋转蒸发仪,高精度温湿度计,露点仪,高效液相色谱仪价格,霉菌试验箱,跌落试验台,离子色谱仪价格,噪声计,高压灭菌器,集菌仪,接地电阻测试仪型号,柱温箱,旋涡混合仪,电热套,场强仪万能材料试验机价格,洗瓶机,匀浆机,耐候试验箱,熔融指数仪,透射电子显微镜。

静电场测试仪中文说明书

静电场测试仪中文说明书

六. 仪器校正……………………………………………………………12
-3-
EFM 022 CPS 操作说明-APS-10
一. 产品描述 EFM022采用旋转叶片式探头测量场强, 旋转叶片式设计比振动式灵敏度高, 更适合连续 性长时间测量. 仪器外壳为EMV塑料, 有效屏蔽信号干扰. 测量值显示在液晶屏幕上, 屏幕第一行显示选定的测试距离, 第二行显示测量值. 产品特性: l 自动将场强V/m根据选定的测试距离转换为静电位V(伏) l 测量前不需要清零 l 单键操作, 非常简单 l 电池过低, 自动关机; 待机时间超过5分钟自动关机 l 可转换成CPS模式以测量静电消除器的散电时间和离子平衡度 产品尺寸: 70 x 122 x 26mm(L x B x H) 产品重量: 130克 测量误差: <5% 9V Alkaline电池或NiMH可充电池 电池连续工作时间: 10小时 测试范围: 测试距离 1 cm 2 cm 5 cm 10 cm 20 cm CPS 模式
-7-
EFM 022 CPS 操作说明-APS-10
三. 产品维护 不要接触探测头, 防止灰尘, 油漆, 液体等物掉进探测头, 长时间使用后可用洁净棉签和 纯净酒精清洁探测头. 注意! 清洁探头时必需小心, 一旦旋转叶片失去平衡会造成测试误差甚至故障
清洁探测头叶片(图 3) 当”Low Battery”显示时, 需更换 9V Alkaline 或 NiMH 电池. 清零调节: 正常情况下, 仪表不需清零, 长时间使用后如果开机屏幕不能显示 U=000, 可 用十字小起子插入仪器右側面清零孔, 旋转内部调节螺丝强制清零. 精度调节: 仪表左侧面 QC 标签后面有一个精度调节孔, 校正仪表时可用十字小起子插 入该孔, 旋转内部调节螺丝来调节测试精度.

FMX静电测试仪

FMX静电测试仪

说明手册FMX-003静电测试计重要SIMCO 推荐在安装和操作此设备前完整阅读此说明书。

否则可能造成个人受伤和设备损坏。

此手册包含的产品覆盖了一个或多个以下美国的专利:3892614; 4092543; 4188530; 4216518; 4423462; 4529940; 4665462; 4716371; 4734580; 4774472; 4872083; 4860159; 5017876; 5153811; 5008594; 4836044; 5930105; 6088211; US6259591 B1 以及对应的国外专利,美国和外国待决专利。

目录第一部分- 安全说明页码 2第二部分-介绍页码3第三部分-规格页码4第四部分-准备页码6第五部分-操作页码7第六部分-离子平衡测量的操作页码10第七部分-重要说明和警告页码11第八部分-问题解决页码12第九部分-保修页码13第一部分- 安全说明DANGER(危险)表示某种即可危险情形,如果没有避免,可能造成死亡或严重受伤WARNING(警告)表明某种潜在危险的情形,如果没有避免,可能造成死亡或严重受伤CAUTION/提醒警告表明某种潜在危险的情形,如果没有避免,可能造成财产损害NOTE/注释表明必要的预防措施以避免潜在设备失误安全说明必须按照此手册的说明去安装和保修该设备警告-此设备没有说明一些典型的危险环境。

不能在暴露的易燃或腐蚀的环境使用。

FMX-003 必须在无水,无油,溶剂及其他导电污染物的区域使用,否则将引起必须避免的产品隔电系统的失误. 仪表上形成的水必须避免。

不要在靠近酸性偶然腐蚀性油气操作。

FMX-003 必须适当接地以保证功能准确。

FMX-003 包含一个感应器,对机械振动和震撼很敏感,如果掉地上很可能损坏。

在这样的FMX-003 包含一个微电脑芯片. 不能在过量电磁噪音的环境中使用。

FMX-003的内部板不能和国外联系。

当电压读数在测量范围以外的测量可疑。

ESD工具(静电场强度测试仪)使用手册

ESD工具(静电场强度测试仪)使用手册

一、仪表介绍
电源开关 定位光圈输出端
二、使用方法
1、打开测试仪的电源开关,LCD上显示一个零点几千伏的读数;
2、打开电源开关的同时,仪器的前端会发出两个光圈,如图1;
3、前后移动仪器,将光圈重合在待测物体的表面,这时仪表的读数就是被测物的表面静电压。

如图2。

静电场强度测试仪12
1
2
图1图2
三、离子风机新购设备的验收及使用中的定期检测方法
新购设备测试:
偏移电压(offset voltage):在置于离子化环境中的CPM的充电平板上观测到的残留电压,小于±35V为合格。

衰减时间(decay time):在置于离子化环境中的CPM的充电平板上的电压由±1000V变化到±100所用的时间,td≤10s为合格。

使用当中的离子化设备用以下方法每季度检测一次其有效性:
A、准备好OHP纸,使用OHP纸摩擦OHP纸,摩擦使之带电,对带电的OHP纸进行电位测试,希望带电量在 ±0.5 KV 以上。

B、将带电的OHP纸,放在离子风机有效范围内,放置2-3秒钟,再对进行OHP电位测试,电压
静电压测试仪
下降到100V以内为合格。

离子风机
离子风
OHP纸
C、使用SIMCO FMX003多功能静电电压测量仪,安装专用充离子平衡测量板后,置于离子化设备作用的工作区(离子风机一般距离为30~100CM)开机状态下记录其电压值,该指标每季度测量一次。

测量结果记录在《静电消除设备--定期检测记录表》中
压,。

SIMCO FMX003使用手册

SIMCO FMX003使用手册

SIMCO FMX003Electrostatic Fieldmeter使用手册Rev: HK-021126-1SIMCO FMX-003SIMCO FMX003静电场测量仪,以非接触式方式,透过测量目标表面的静电位,来表示在其上的静电荷量。

它可附加配件,测量离子产生器的离子平衡。

Section 1:简介Section 2:特色Section 3:规格Section 4:安全使用守则Section 5:安装指引Section 6:操作指引Section 7:保养指引Section 8:可更换部件一览Section 9:保证World Leader in Static Conlrol? Since 1936 (ISO9001 Cortified) Page 1 of 8Section 1:简介SIMCO FMX003静电测量仪,以非接触式方式,透过测量目标表面的等静电位,来表示在其上的静电荷量。

它十分轻巧,精确。

易携和易用。

它内置微控处理器,可简单地按红色的电源(POWER)按掣开关,按灰色的返零(ZERO)按掣调整零点,更按绿色的冻结显示(HOLD)按掣。

方便在难以观看显示结果的测量点时,冻结显示后取出再记录。

转换(IB)按掣方便测量操作。

利用两盏LED灯的对焦点,精确地决定测量距离为25mm,并准确地测量该距离的静电电位值,以表示在目标表面上的静电荷,它的测量范围是+/-20kv。

它的外壳是导电材质,若再接上接地线,则能确保测量结果的有效性。

SIMCO FMX003静电测量仪,亦可配上离子平衡测量板,以评估离子产生器的离子平衡Section 2:特色●SIMCO FMX003可测范围在 +/-20 kV.●置有2 LED灯确保测量距离在标准25mm处.●外壳为导电材质, 并有接地扣, 确保测量结果正确可靠.●显示有数字和图形, 清晰明确. 在暗黑环境下, 更可着亮面板显示灯光.●并附有离子平衡测量板, 测量离子产生器的残余电压, 可测范围+/-200V.●电场测量范围+/- 20kV●2 LED 确定25mm工作距离●附有离子平衡测量板 (+/-200V)●单按归零重置●单按显示锁定●闲置自动关机●电池效能显示●面板显示灯光World Leader in Static Conlrol? Since 1936 (ISO9001 Cortified) Page 2 of 8Section 3:规格输入电压9 V battery静电场可测+/-(0.00-20.0kv)(自动显示调整)标准测距25mm +/- 1mm离子平衡可测+/-(0-200V)测量距离根据ESD-STM3。

SIMCOION静电测试仪FMX-003替代型号FMX-004产品详情和检测方法

SIMCOION静电测试仪FMX-003替代型号FMX-004产品详情和检测方法

SIMCOION静电测试仪FMX-003替代型号FMX-004产品详情和检测方法
FMX-004替代FMX-003是一款搭载单芯片计算机的多机能数字测试仪,手掌大小的紧凑设计采用容易看的大LCD显示,最大±30kV(测定距离:25mm),用于简单的带电测定,静电发生场所特定的带电水平调查,静电应对的方案、效果的测定,维持管理等。

特点
3种检测方法
根据MODE按键的转换选择测定范围。

静电连续测定
离子平衡连续测定和数据记录可能。

測定結果画面表示和记录一体记忆
制品的除电状态确认记录。

FMX-004本体:可连续30小时测试
离子平衡测定
离子平衡测定方式根据防静电器的性能确认
±300V的电位测定是各种除静电器最适度的保养。

离子平衡板不使用時,从本体后面装上保管产品规格
替代FMX-003。

FR4003电场测量设备说明书

FR4003电场测量设备说明书

Main Features• 9 kHz to 30 MHz frequency range• Antenna CISPR 12, CISPR 16, CISPR 25, MIL-STD, DO-160 fully compliant • Internal full CISPR 16-1-1 receiver• Embedeed Attenuator, Preamplifier and Preselectors • Fiber optic serial link to 9010 series or directly to PC • Grounding Effectiveness Auto-Diagnostic Capability • On board tracking generator and antenna CISPR adapter • Automatic diagnostic and calibration • Scattering free • PC softwares• RF Front-End Output• On board capacitance meter •Replaceable Li-Ion batteryThe FR4003 is a new reference in measuring electric fields up to 30 MHz. Thanks to its innovative approach it replaces traditional rod antennas adding several benefits. It fully meets all MIL-STD and CISPR specifications of the rod antenna and it is a real full compliant CISPR 16-1-1 receiver with the capability of working, via fiber optic link, either stand alone when connected to a PC or connected to a PMM receiver. N onetheless, it can maintain full legacy with any standard receiver, because it also has the traditional coaxial cable output. However, this way is not recommended as the cable has a significant influence, such as scattering, which is one of the major drawbacks of rod antennas.The internal receiver structure features preselectors, attenuators and preamplifiers fully controlled either by the internal firmware or manually by the operator. Hence, a test set-up does not need any additional receiver. Moreover, an internal tracking generator allows performing a self-calibration procedure which always guarantees optimum performances, ensuring the accuracy of measurements. The same internal tracking generator is part of an internal capacitance meter that becomes essential not only for the self-calibration, but also for verifying the grounding effectiveness of the st but not least, the FR4003 can become a field generator. In this case the antenna broadcasts the signal made by the internal signal generator and can thus be used to characterize environments or other receiving set-ups.In addition to the standard PEMS software, the FR4003 comes also with a controlling software, which can be used when connected to a standard receiver. Thanks to its replaceable Li-Ion battery, the FR4003 can work for several hours with no connection having thus unperturbed field.Field ReceiverFR4003PRELIMINARYOrdering Information:FR4003 Field ReceiverInclude: 50 ohm to rod capacitance fixture for CISPR calibration; 15 pF fixture for capacitance meter calibration; MILSTD 40 mm rod extention; 600x600 mm counterpoise, battery pack; AC adapter/charger; PC softwares; 20 m high speed fiber optic for 9010F; 10 m plastic fibre optic for PC; USB-fiber optic adapter; certificate of calibration; operating manual.Optional accessories:Li-ion Battery Pack BP-01High speed Fiber optic cable 9010/FO-20 (length: 20m)High speed Fiber optic cable 9010/FO-50 (length: 50m)High speed Fiber optic cable 9010/FO-100 (length: 100m)10 m plastic fiber optic for PC 20 m plastic fiber optic for PC 40 m plastic fiber optic for PC USB-fiber optic adapterTR-01 Wooden tripod extensible 60 - 180 cmReceiversAntennasLISN&Probes• 7010/00: EMI receiver 150 kHz to 1 GHz • 7010/01: EMI receiver 9 kHz to 1 GHz • 7010/02: EMI receiver 9 kHz to 30 MHz • 7010/03: EMI receiver 9 kHz to 3 GHz • 9010: EMI Receiver 10 Hz to 30 MHz • 9010F: EMI Receiver 10 Hz to 30 MHz• 9010/03P: EMI Receiver 10 Hz to 300 MHz • 9010/30P: EMI Receiver 10 Hz to 3 GHz • 9010/60P: EMI Receiver 10 Hz to 6 GHz • 9030: EMI Receiver 30 MHz to 3 GHz • 9060: EMI Receiver 30 MHz to 6 GHz • 9180: EMI Receiver 6 GHz to 18 GHz•9010/Click4E: Four Channels Click Meter• BC-01: Biconical Antenna 30 to 200 MHz• LP-02: Log Periodic Antenna 200 MHz to 3 GHz • LP-03: Log Periodic Antenna 800 MHz to 6 GHz• VDH-01: Van der Hoofden test-head 20 kHz to 10 MHz • TR-01: Antenna Tripod• Antenna Set AS-02 (BC01+LP02+TR01)• Antenna Set AS-03 (BC01+LP02+LP03+TR01)• RA01: Rod Antenna 9 kHz to 30 MHz• RA01-HV: Rod Antenna 150 kHz to 30 MHz •RA01-MIL: Rod Antenna 9 kHz to 30 MHz• L2-16B: single phase AMN, 16 A • L3-32: 4 lines, 3-phase AMN, 32 A • L3-64: 4 lines, 3-phase AMN, 63 A• L3-64/690V: 4 lines, 3-phase AMN, 63 A • L3-100: 4 lines, 3-phase AMN, 100 A• L1-150M: single-path, 50 Ohm AMN, 150 A • L1-150M1: single-path, 50 Ohm AMN, 150 A • L1-500: single phase AMN, 500 A • L3-500: 4 lines, 3-phase AMN, 500 A • L2-D: Delta LISN for telecom, 2 A, 150 Ω• SBRF4: RF Switching Box• SHC-1/1000: Voltage probe, 1000 Vac, 35 dB •SHC-2/1000: Voltage prove, 1000 Vac, 30 dBRelated ProductsF R 4003-F E N -50202 - S p e c i fi c a t i o n s s u b j e c t t o c h a n g e s w i t h o u t p r i o r n o t i c eHeadquarter:Via Benessea, 29/B17035 Cisano sul Neva (SV) - ITALY Phone: +39 0182 58641Fax: +39 0182 586400E-Mail:**************************Internet: www.narda-sts.itSales Office:Via Leonardo da Vinci, 21/2320090 Segrate (Milano) - ITALY Phone: +39 02 2699871Fax: +39 02 26998700FR4003Field ReceiverFrequency rangeResolutionFrequency accuracy RF Input Attenuator HPFPreamplifier gain Max input levelPreamp OFF, Att 20/30 dB Preamp OFF, Att 0/10 dB Preamp ON, Att 0/10 dB Damage level Noise levelPreamp ON, Att 0 dB, 1 kHz RBW Spurious responseMeasurement accuracy PreselectorInternal receiverIF bandwidth 6 dB bandwidth Level measuring time (hold time)DetectorsDemodulation Antenna FactorAt BNC service analog output Analog output Internal generator Frequency range Frequency resolution Level range Level resolution Level accuracyInternal capacitance meter Range Resolution Calibration Auto testAuto calibrationFiber optic connection PC softwares Display unitswith PMM Emission Suite SWStandard conformityFW updatingOperating temperature Power Supply Tripod supportDimensions and weights (Overall W x D x H)9 kHz to 30 MHz 1 Hz < 1 ppmHigh impedance N fem.Built-in 0 dB to 30 dB (10 dB steps)Built-in 9 kHz or 150 kHz HPF (selectable)Built-in 10 dB gain (selectable)SPECIFICATIONSInternal process (SD with HPF 9 kHz and Preselector ON)100/104 cm rod N input12 V/m CW128 dBµV/m/MHz SD 1,2 V/m CW107 dBµV CW98 dBµV/m/MHz SD84 dBµV/MHz SD 0,35 V/m CW 97 dBµV CW88 dBµV/m/MHz SD 74 dBµV/MHz SDBNC analog output saturation (1 dB compression point @ 1MHz)(SD Spectral Density with HPF 9 kHz)100/104 cm rod N input380 V/m CW137 dBµV/m/MHz SD38 V/m CW 137 dBµV CW117 dBµV/m/MHz SD 103 dBµV/MHz SD 14 V/m CW 129 dBµV CW 108 dBµV/m/MHz SD 94 dBµV/MHz SD Two highpass filters: 9 kHz 150 kHzFive bandpass filters: 9 kHz to 5,67 MHz 5,67 MHz to 11,19 MHz 11,19 MHz to 16,71 MHz 16,71 MHz to 22,23 MHz 22,23 MHz to 30 MHzFully digital Fast Fourier Transform based. Operates both in conjunction with 9010F and in stand alone 3, 10, 30, 100, 300 kHz200 Hz, 9 kHz ( CISPR 16-1-1)10, 100 Hz and 1, 10 kHz (MIL-STD-461) (Option)CISPR 16-1-1 as default 0,2 ms to 120 sPeak, Quasi-Peak, Average, RMS, RMS-Average (Optional), C-Average Smart Detector functionAM (In conjunction with PMM 9010)-10 dB/m (Att 0 dB PreAmp ON)50 Ω BNC fem.Tracking & CW generator (for auto calibration, capacitance meter and field source)9 kHz to 30 MHz 1 Hz65 to 95 dBuV 1 dB 0,3 dB0 to 100 pF 0,01 pFAutomatic by external text fixtures Automatic at power onThrough internal generator and matching network RP-02 series serial optical interface 115 Kbaud 9010/9010F series high speed optical interface PMM Emission suite – PMM FR4003 UtilitydBm, dBµV, dBµA, dBpW, dBµV/m, dBµA/m, dBpT 80 to 200 dB selectable dynamic rangeCISPR 16-1-1, MIL-STD 461F full compliant on board receiverCISPR 12, CISPR 25, MIL-STD 461F, DO-160 full compliant rod antenna Through the optical link by USB or RS232-10° to 60°C7,4 V - 6,9 Ah Li-Ion rechargeable & interchangeable battery (8h operations, typical)Threaded insert UNC ¼“Receiver 134 x 285 x 84 mm 2,40 kg Counterpoise 600 x 600 x 2 mm 4,15 kg Rod (1000 mm) Ø 29 x 1020 mm 0,50 kgRod extension (40 mm) Ø 20 x 47 mm 0,05 kg TOTAL (w rod ext.) 600 x 600 x 1122 mm 4,85 kg100/104 cm rod N input (50 Ω term) -5 dBµV/m -13,5 dBµV500 V/m CW< -5 dBuV; < 10 dBuV over 150 kHz (Att 0 dB, 50 Ω term, AVG, Ht 10 ms, RBW auto)9 kHz to 30 MHz ± 0,8 dBLINK1EMI ReceiverPMM Emission Suite LINK2FR4003 Field ReceiverUSBHigh speed fibre opticFibre opticPRELIMINARY。

FMX-003静电场测试仪中文使用说明(1)

FMX-003静电场测试仪中文使用说明(1)

Simco便携式数字静电测量仪型号FMX-003指导书安装/操作/维护注意在你试图安装或者操作之前仔细阅读和理解这些指导是非常重要的。

没有这么做可能会造成严重的个人受伤及[或] 损坏仪器. 在这一本手册最后部分提供有一手写的保证证书。

请小心地保存起来.使用者注意事项注意此仪器没有设计在机密的(危险的) 环境下使用. 它不能够被暴露用于易起火的或腐蚀的材料和气体中.注意此仪器专门用于静电的处理,需要远离水,油,溶剂和其他具有传导性的污染物. 对暴露在如此的污染物中将会引起产品的电气绝缘故障. 特别小心确定环境没有露珠形成. 此仪器应该在一个湿度小于60% 的环境下保存和使用.不要插入任何的物体于用于固定感应器的口子里;不要有任何异物进入感应器的开口.这个仪器不能在有腐蚀性的酸/碱烟或腐蚀性的气体如氯之类的环境中使用操作. 这个仪器是用电池操作的,不要连接任何其他电线. 正常的操作条件在它的名牌上有列出. 当不使用的时候,请关闭仪器.为了仪器精确的测量请将他正确的接地.如果跌落,此仪器很容易损坏。

如果发生此类事情,它应该交由授权的技术人员做仔细的检查和必要的修理. 此仪器为电子设备,其包含的传感器可能对机械的震动和冲击非常敏感. 当然它也包含有一个微型处理芯片和电子电路,所以它不能在有许多电子噪音的环境中使用.当电压读数超出测定范围之外的时候会中止测量. 如果超过量程使用,有可能损坏感应器.在离子化的空气中使用该产品是可能的。

但是在这种情况下正描述的10% 精度不能够被保证.不要在LCD 屏幕的上方施加任何压力.此仪器在25 ± 0.5 毫米的测定距离已经被校正. 对于超出此距离校正是无效的. 不要干预感应器位置和LED方向,否则可能改变测定距离.该仪器在Simco 日本公司装配和检查. 请不要试图拆解或改变它的构造. 如果你不清楚有关它的操作事项和维护,请联系你所在区域的Simco 日本公司的授权代理人.第1页谢谢你购买Simco 产品. 当仪器被正确的安装和维护后,将会迎合你的要求并提供安全的操作.仪器清单请小心地将仪器从硬纸盒移出并且检查. 注意任何可能在运输期间发生的损坏. 倒空硬纸盒确定没有小部份被丢弃.如果在运输期间发生任何的损害,请立刻通知当地的运输员. 损坏报告应该立即寄到SIMCO 日本公司. 地址和其他的相关信息在背面封页上有写.包装项目和配件(1) FMX-003 静电场测试……………………………………………………… 1件(2) 离子平衡盘…………………………………………………………………….1件(3) 1 m 长接地线…………………………………………………………………1件(4) 软皮包………………………………………………………………………….1件(5) 电池(类型6 F22,9 V)…………………………………………………….. 1件(6) 操作手册/证书(这一本书) ……………………………………………….. 1件请检查是否有部件不见或没有满意的完成. 如果这样的情况发生,请连络我们或我们的代理人.第2页内容使用者注意 (1)收到仪器 (2)包装项目和配件 (2)目录 (3)第一节一般的描述 (4)第二节特征 (5)第三节规格 (6)第四节外观 (7)第五节电源 (8)第六节静电荷测量 (9)第七节离子平衡测量 (14)第八节功能表 (20)第九节故障解决 (21)SIMCO 仪器设备维修保证………………………………………………………符号的解释:警告注意/小心电击危险第3页第一节一般的描述SIMCO FMX-003 型号静电测试仪是一个专门用于测定静电电压的简单仪器. 它小巧(口袋大小) ,便携,便利容易使用.它内部有一个微处理器. 通过电源开关(红色的) 可以将静电测试仪打开或者关闭. 一个标着零的灰色按键是用来做归零调整的. 一个标着HOLD的绿色按键是用来保持显示数据的,这在当测量过程中显示很难辨认时是非常有用的.SIMCO FMX-003 能在25 ㎜位置能够准确的测量出静态电压在± 20000 V 内的静电电压. 在感应器旁边的两个LED光环是用来帮助定位测量仪到电荷体之间的正确距离. 传导性外壳和易接地端口容易方便接地,以便正确测量.FMX-003 也可以作为静电压离子平衡电压地测量. 通过安装一个离子平衡盘,并且将标有IB 的蓝色按钮转换至IB 状态,便可以对离子平衡电压为± 200 V 的电压进行测量。

Simco-Ion FMX-004 静电场测量仪 用户手册说明书

Simco-Ion FMX-004 静电场测量仪 用户手册说明书

FMX-004 静电场测量仪 用户手册 关于Simco-Ion Simco-Ion 开发、制造并销售对静电荷进行控制的系统解决方案。

作为全球最大的静电控制产品和服务供应商,Simco-Ion 针对客户的静电放电和电磁干扰问题,提供整体解决方案,从而提高客户的经营成果。

Simco-Ion Technology Group 为Illinois Tool Works (ITW) 的分部,位于加利福尼亚阿拉米达。

欲知Simco-Ion 的详细信息,Simco Japan 株式会社Ion Systems 的徽标 和 Simco 的徽标是 Simco-Ion, An ITW Company 的注册商标。

© 2017 Simco-Ion离子解决方案重 要 安 全 信 息在安装和操作本设备前,请仔细阅读下列安全信息。

未遵守这些安全警告,会导致您的离子系统损坏及/或产品保修无效。

FMX-004不是设计用于有归类(危险的)的环境中。

在有易燃或腐蚀性物料的附近,也都不能使用。

FMX-004适用于没有水,油,溶剂和其他导电污染物的区域。

暴露于这种污染物将导致产品中电气绝缘系统的故障。

必须避免在潮湿凝有露珠的环境使用。

为了保持测试平板的高绝缘性,FMX-004应存放在低于60%RH 的地方。

放在带有干燥剂的塑料拉链袋内。

不要在酸碱等腐蚀性气体或氯气等腐蚀性气体附近操作。

FMX-004不是防爆产品。

不要在易燃气体中使用本产品,如油漆稀释剂,苯,汽油,丙烷,天然气等。

FMX-004必须正确接地才能工作精确,适当的接地对于敏感的离子平衡测量至关重要。

FMX-004内有对机械振动和冲击敏感的感测器,如果掉落,可能会损坏。

如果发生这种情况,应该请经授权的技术人员仔细检查和修理。

FMX-004电路板上有微控芯片。

不应在电磁噪音过大的环境中使用。

FMX-004的内部不应与外物接触。

应在干净和干燥的环境中存放和使用。

当电压读数超出测量范围时应暂停测量。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

Simco便携式数字静电测量仪型号FMX-003指导书安装/操作/维护注意在你试图安装或者操作之前仔细阅读和理解这些指导是非常重要的。

没有这么做可能会造成严重的个人受伤及[或] 损坏仪器. 在这一本手册最后部分提供有一手写的保证证书。

请小心地保存起来.使用者注意事项注意此仪器没有设计在机密的(危险的) 环境下使用. 它不能够被暴露用于易起火的或腐蚀的材料和气体中.注意此仪器专门用于静电的处理,需要远离水,油,溶剂和其他具有传导性的污染物. 对暴露在如此的污染物中将会引起产品的电气绝缘故障. 特别小心确定环境没有露珠形成. 此仪器应该在一个湿度小于60% 的环境下保存和使用.不要插入任何的物体于用于固定感应器的口子里;不要有任何异物进入感应器的开口.这个仪器不能在有腐蚀性的酸/碱烟或腐蚀性的气体如氯之类的环境中使用操作. 这个仪器是用电池操作的,不要连接任何其他电线. 正常的操作条件在它的名牌上有列出. 当不使用的时候,请关闭仪器.为了仪器精确的测量请将他正确的接地.如果跌落,此仪器很容易损坏。

如果发生此类事情,它应该交由授权的技术人员做仔细的检查和必要的修理. 此仪器为电子设备,其包含的传感器可能对机械的震动和冲击非常敏感. 当然它也包含有一个微型处理芯片和电子电路,所以它不能在有许多电子噪音的环境中使用.当电压读数超出测定范围之外的时候会中止测量. 如果超过量程使用,有可能损坏感应器.在离子化的空气中使用该产品是可能的。

但是在这种情况下正描述的10% 精度不能够被保证.不要在LCD 屏幕的上方施加任何压力.此仪器在25 ± 0.5 毫米的测定距离已经被校正. 对于超出此距离校正是无效的. 不要干预感应器位置和LED方向,否则可能改变测定距离.该仪器在Simco 日本公司装配和检查. 请不要试图拆解或改变它的构造. 如果你不清楚有关它的操作事项和维护,请联系你所在区域的Simco 日本公司的授权代理人.第1页谢谢你购买Simco 产品. 当仪器被正确的安装和维护后,将会迎合你的要求并提供安全的操作.仪器清单请小心地将仪器从硬纸盒移出并且检查. 注意任何可能在运输期间发生的损坏. 倒空硬纸盒确定没有小部份被丢弃.如果在运输期间发生任何的损害,请立刻通知当地的运输员. 损坏报告应该立即寄到SIMCO 日本公司. 地址和其他的相关信息在背面封页上有写.包装项目和配件(1) FMX-003 静电场测试……………………………………………………… 1件(2) 离子平衡盘…………………………………………………………………….1件(3) 1 m 长接地线…………………………………………………………………1件(4) 软皮包………………………………………………………………………….1件(5) 电池(类型6 F22,9 V)…………………………………………………….. 1件(6) 操作手册/证书(这一本书) ……………………………………………….. 1件请检查是否有部件不见或没有满意的完成. 如果这样的情况发生,请连络我们或我们的代理人.第2页内容使用者注意 (1)收到仪器 (2)包装项目和配件 (2)目录 (3)第一节一般的描述 (4)第二节特征 (5)第三节规格 (6)第四节外观 (7)第五节电源 (8)第六节静电荷测量 (9)第七节离子平衡测量 (14)第八节功能表 (20)第九节故障解决 (21)SIMCO 仪器设备维修保证………………………………………………………符号的解释:警告注意/小心电击危险第3页第一节一般的描述SIMCO FMX-003 型号静电测试仪是一个专门用于测定静电电压的简单仪器. 它小巧(口袋大小) ,便携,便利容易使用.它内部有一个微处理器. 通过电源开关(红色的) 可以将静电测试仪打开或者关闭. 一个标着零的灰色按键是用来做归零调整的. 一个标着HOLD的绿色按键是用来保持显示数据的,这在当测量过程中显示很难辨认时是非常有用的.SIMCO FMX-003 能在25 ㎜位置能够准确的测量出静态电压在± 20000 V 内的静电电压. 在感应器旁边的两个LED光环是用来帮助定位测量仪到电荷体之间的正确距离. 传导性外壳和易接地端口容易方便接地,以便正确测量.FMX-003 也可以作为静电压离子平衡电压地测量. 通过安装一个离子平衡盘,并且将标有IB 的蓝色按钮转换至IB 状态,便可以对离子平衡电压为± 200 V 的电压进行测量。

当平衡盘在不使用的时候,可以安装在FMX-003 的任何一端。

此仪器的紧凑设计使得测量比较容易,并且在某些难接近的工作区域能够使用。

它有多方面的应用如用来决定静电消除器的位置,研究静电的电荷水平,是否需要离子中和,及对静电消除器的维护有相关的帮助,等等.第4页INST-05070410第二节特征FMX-003 的特有特征为;●紧凑和轻巧的机身●多功能微处理器芯片●宽大的数字显示屏●正数(红色的) 和负数(蓝色的) 曲线图表显示栏●平衡盘的容易安装方便离子平衡的测量●数字归零功能●电源自动关闭功能●保持功能●感应器故障显示"犯错"●引导了灯引导指示距离●电池情况显示(4 个阶段)●显示灯在不够光时协助读数-第5页INST-05070410第三节. 规格静电电压测量范围: 0 ± 1.49 KV(低量程)±1.0 KV ~± 20.0 KV(高量程) 离子平衡电压测量范围: 0 ~± 200 V测量距离: 25 ㎜± 0.5 ㎜(在带电体和测量仪器之间) 响应时间: 少于一秒LCD 显示更新率: 5 次/秒准确性: ± 10%环境条件: 10 ~40 ℃和0 ~60% RH显示: 大的LCD 显示(数字和曲线图栏)曲线栏: 红色的LCD 表示正极电压蓝色的LCD 负极电压精度:± 0.1 KV 在低量程测量时±1.5 KV 在高量程测量时±15 V 在离子平衡测量时数传读取: □.□□===)0.0 ~± 1.49KV (低量程)□□.□===)± 1.0 KV~± 20.0KV (高量程)□□□===)0~±200V(离子平衡)[IB]: 离子平衡测量模式[HOLD]: 在测量后保保持显示[A.OFF]: 电源自动关闭功能解除[ERR]:感应器损坏时错误表示电池状况显示(4 个阶段)显示灯:LED白色灯帮助在不够光时阅读在下列各项功能时听到哔哔声:*当按住电源开关少于3 秒的时候,电源被打开: 一声哔哔声*当按住电源开关超过3 秒的时候,电源被打开: 三声哔哔声(电源自动关闭功能取消)*电源自动关闭指示: 在电源关闭之前每隔一秒响一次连续五秒*超量程: 连续的警告声电源自动关闭:如果仪器在大约五分钟之久没有操作电源自动关闭. 如果要连续的操作,那么在开机时应该按住红色的电源开关键超过三秒.电源: 9 V,6 F22Y 锰电池;寿命: 大概30 h整体大小: 115 毫米(L) x 73 毫米(W) x 25 毫米(H);没有离子平衡盘123 毫米(L) x 73 毫米(W) x 25 毫米(H);有离子平衡盘重量: 连电池为140 g 为静电电压测量连电池和离子平衡盘为170 g外壳材料: 传导性的树脂(ABS)第6页INST-05070410第四节外观第7页第五节电源5.1 电源该仪器是用电池操作的,不要连接任何其他线。

在运输过程中电池是没有安装的. 安装电池请依照5.2 程序中更换电池的方法执行。

5.2 电池更换FMX-003 使用9 V,6 F22 锰电池. 电池的寿命大约30 个小时. 当FMX-003 电源被打开,电池状态如下面的图片显示。

当显示电池空的时候,请更换电池. 注意在电池指示图片中黑暗区域不与剩余的电量成比例.[更换程序]①在FMX-003 后面的有一个电池盒. 按下标有"OPEN" 凹下部分,滑动打开盖子.②小心地除去旧的电池(如果存在).③连接新的电池,装入电池箱. 请确定电池的极性. 在运输过程中电池没有被安装. 有一个电池被附在同一个包装里.④重新装好盖子.警告*不要施加过度的压力;它可能损坏盖子.*当连接或分离电池时候,要小心不要把连接端子损坏.*当电池被强制地以错误极性装入时,端子将会被损坏.*在关闭电池盖前,请确定没有线端子部份露在电池箱之外.第8页INST-05070410第六节静电测量FMX-003 有四个按钮可以运行许多功能. 按钮颜色命名功能6.1接地如果FMX-003 没有可靠的接地,那么它的精度可能被测量人员身上的静电影响. 对于正确的测量,操作员应该配带一根防静电腕带及[或] FMX-003 应该用提供的接地线插入右侧的接地口正确的接地.注意FMX-003 的外壳是用导电性的树脂做成的。

接地端口给电路提供一个零电压参考。

这个端口必须可靠的接地才能可靠的测量。

如果没有可靠的接地,那么她的精度是没有保障的.6.2 测量模态的选择无论自动关闭功能是否开启,有两种操作模式可以使用.6.2.1 标准模式测量静电(电压)①将FMX-003 的感应器朝着没有静电的地方,快速按一下标有POWER的按键量. 一声哔哔声(0.25 秒) 声将会听到提示FMX-003 进入标准测量模式.②当电源被打开,LCD 屏幕显示数值,极性,测量单位"KV",曲线图刻度,电池电量状况. 此时,请参照第五节电池的状况所描述确认电池的状态. 感应器旁边的两个红色的LED灯点亮,表示FMX-003 已经准备进行静电测量.第9页INST-05070410③电源打开五分钟后,FMX-003 将会自动关闭。

这就叫做自动关闭功能。

此时,每秒二声哔哔声连续五次提示FMX-003 将会很快被关闭.④当电源是打开的时候,如果按POWER键,FMX-003 将会关闭所有指示消失. 注意*FMX-003 可能被藉由仅仅轻轻的压力导致开机. 没有需要重复地按它. 频繁的没有必要的开关机操作,或者用指甲按它可能会影响开关的寿命和损坏印刷薄膜. *在标准模式中,当自动关闭功能开启,测量不能超过五分钟. 对于连续超过五分钟的测量,请按照下一节所描述的操作.6.2.2 连续模式进行静电(电压) 测量①将FMX-003 的感应器朝着没有静电的地方,按住POWER键三秒以上。

此时右上方的红色图表栏中的红色条将会每秒增加一条,当三根红色条出现时,放开POWER键. 三声哔哔声提示FMX-003 进入连续的测量模式. 这就叫做"取消自动关闭功能". 如果使POWER按钮按住五秒,一个白色LED灯在屏幕下边点亮. 这帮助在房间光线弱时帮助读数.LED灯也可以按住POWER键长于一秒少于三秒打开. 如果按住时间少于一秒或者多于三秒而少于五秒那么LED灯不会打开.②在连续测量模式下,,LCD 屏幕显示数值,极性,测量单位"KV",线刻度,电池电量状况A。

相关文档
最新文档