中压燃气管道设计说明

合集下载

燃气设计说明书

燃气设计说明书

—摘要城市燃气是城市建设的重要基础设施之一,也是城市能源供应当中一个重要组成部分,它为城市工业、商业和居民生活提供优质气体燃料。

城市燃气输配系统的绝大部分系统的绝大部分工程量,属与城市地下基础工程。

本设计的主要内容为老城区天然气供应的规划。

该设计使用的天然气管道主要是无缝钢管。

XX区总供气面积为237公顷,人口达万,属于小型城市,居住也比较集中。

进行规划时除建设接收长输管线天然气的门站外,还设置区域调压站。

因此,除管网的水利计算外,还有门站,区域调压站的设备选型计算。

本设计囊括了从长输管线到门站,经过区域调压站最后进入区域管网的过程。

幸福小区有79栋楼,共948户,包括了平面管网的布置,用户引入管的设计,单管阀门井的设计,凝水缸的设计。

关键词:天然气门站管道工艺流程节点压力流量"Abstract`City gas is an important city-building infrastructure as urban energy is also an important component of the urban industrial, commercial and residential gas by the ways of providing quality gas . City gas transmission and distribution system is a basic project of the urban underground works in the vast majority of engineering systems.The main elements of the design is the planning of natural gas supply in Laocheng district . Seamless steel pipe is used as gas pipeline in this design. Laocheng district which covers a supply area of 237 hectares , population 94,800, is a small city and the living is also relatively concentrated. Not only is a gas storage and distribution station in need ,but also a regional regulator station need to be set up when planning to receive long-distance pipeline. Therefore, in addition to the water pipe network computing, there are equipment selections of Storage and Distribution Station, regional regulator stations .The design mainly includeslong-distance pipelines from the reservoir distribution stations, regulator stations, after the regional final to enter the process of regional pipeline network. There were79 residential buildings,a total of 948, in Xingfu layout of flat pipe network , the design of user conductor and the design of condensate water tanks are included .Key words: Natural Gas ;Storage and Distribution Station ;pipeline;Technological process ;joint pressure;flux目录1 原始资料 (1)用气量指标 (1)基本参数 (2)"2 天然气性质的计算 (4)天然气平均分子量 (5)天然气的平均密度 (5)相对密度 (6)粘度 (6)爆炸极限 (8)干湿燃气的高低热值 (10)3 用气量的计算 (12)—各类用户用气量计算 (12)绘制储气变化曲线 (15)4 燃气管网规划 (19)燃气管网系统选择和管线的布置原则 (19)调压站 (23)调压器 (27)管道、阀门的选择 (31)水力计算 (34)…5 门站设计 (40)门站设计 (40)门站平面布置 (41)储气罐的选择 (43)6 小区燃气设计 (44)布线 (44)燃气区域调压柜 (49)水力计算 (50)》设备选择 (56)管道埋设 (59)7 设计总结 (61)参考文献 (62)致谢 (63)1 原始资料本设计所给的图纸包括城市规划资料(附城市规划图)、小区平面图(未标明层数的建筑以6层计)。

燃气管道设计要求-概述说明以及解释

燃气管道设计要求-概述说明以及解释

燃气管道设计要求-概述说明以及解释1.引言1.1 概述在燃气管道设计中,为了确保燃气输送的安全可靠性和高效性,设计人员需要遵循一系列的设计要求和原则。

本文旨在探讨燃气管道设计的关键要求,包括设计原则、材料选择和施工要求。

通过深入分析和论述,希望能够为燃气管道设计提供一些建议和指导,从而提高燃气输送系统的运行效率和安全性。

通过对燃气管道设计要求的全面梳理,为未来的燃气管道工程提供可持续发展的指导和支持。

1.2 文章结构文章结构部分将主要包括三个章节,分别是引言、正文和结论。

在引言部分,将对燃气管道设计要求的概述进行介绍,为后续内容提供背景和引入。

在正文部分,将详细探讨燃气管道设计的原则、材料选择以及施工要求,帮助读者全面了解设计要求的重点和关键内容。

最后,在结论部分,将对整篇文章的主要内容进行总结,强调设计要点,并展望未来可能的发展方向,为读者提供全面而深入的理解。

整个文章结构将有助于读者系统地了解燃气管道设计的要求和重要性。

1.3 目的燃气管道设计的目的是确保燃气传输系统的安全、稳定和高效运行。

通过合理设计燃气管道系统,可以有效减少因设计不当而导致的事故风险,保障人民群众生命财产安全。

同时,合理设计还可以提高燃气传输效率,降低能源消耗,减少对环境的影响。

因此,本文旨在介绍燃气管道设计的要求,帮助设计人员更好地了解和遵守相关规范标准,确保燃气管道系统的安全可靠运行。

2.正文2.1 燃气管道设计原则燃气管道设计是确保燃气输送安全可靠的关键环节,其设计原则应遵循以下几点:1. 安全性优先:燃气管道设计应以安全性为首要考虑因素,确保管道在正常运行和突发情况下能够安全运行,避免事故发生。

2. 效率和可靠性:燃气管道设计应注重管道传输效率和系统可靠性,确保燃气能够快速、稳定地输送到指定地点。

3. 环保和节能:燃气管道设计应考虑减少对环境的影响,选择节能环保的设计方案和材料,降低能源消耗和排放。

4. 全面考虑:燃气管道设计需要全面考虑管道输送参数、设备选型、防腐防静电等因素,确保设计方案综合而完善。

中压天然气工程管道施工方案

中压天然气工程管道施工方案

城南路(南高公路~莲塘大道)中压天然气工程施工组织方案编制:审核:批准:编制单位:福建省工业设备安装有限公司二0一0年八月四日一、工程概况1.业主单位:南昌县燃气有限公司.设计单位:南昌市安信市政设计事务所.监理单位:江西省设备工程监理有限公司.施工单位:福建省工业设备安装有限公司.城南路(南高公路~莲塘大道)中压天然气工程,起始点南高公路~莲塘大道,管线全长约2079米。

主要工作内容为沟槽开挖回填、燃气管线安装、附属设备安装等,计划开工日期2010年8月5日,计划竣工日期为2010年11月5日.设计参数:管道规格:*6mm 材质Q235B;管道设计压力:;管道工作压力:小于;设计温度:常温;输送介质:天然气;2.本段工程的主要内容准备工作,交桩、移桩、测量放线、施工作业带清理、开挖管沟,材料检验、运输和布管,管道下沟,组对焊接、无损检测及拍片、补口补伤,清管、试压,管道干燥,阀门安装,土方回填,标志设置,交工验收。

3.主要工程量:三PE高频直缝电阻焊钢管*6 2079米牺牲阳极(镁阳极)保护—11组Z48W-8Q 型阀门DN300—4只、DN200—6只二.编制依据及技术标准本工程施工依据除了合同、设计施工图和设备安装说明书以外,还依据以下现行国家标准和行业标准:1.《城镇燃气设计规范》GB50028—20062.《城镇燃气技术规范》GB50494—20093.《城镇燃气输配工程施工及验收规范》CJJ33—20054.《工业金属管道施工及验收规范》GB50235—975.《金属熔化焊焊接接头射线照相》GB/T3323—20056.《油气输送用钢管弯管》SY/T5257—20047.《钢制对焊无缝管件》GB12459—20058.《钢制管道外腐蚀控制规范》GB/T21447—20089.《埋地钢质管道阴极保护技术措施》GB/T21448—200810.《埋地钢质管道阴极保护参数测量方法》B/T21246—200711.《埋地钢质管道聚乙烯防腐层技术标准》SY/T0413—2002三、工程特点本工程地处于南昌县开发区(南高公路~莲塘大道),为道路施工配合工程。

燃气管道设计、施工说明

燃气管道设计、施工说明

燃气管道设计、施工说明一、设计依据1、广州燃气集团有限公司致本设计所的设计任务委托书。

2、广州燃气2010年发展规划。

3、广州市市区天然气利用工程中压管网工程初步设计。

4、市城市规划局关于本燃气主干管的报建批文及有关附图(穗规建证[2015]第1029号)。

5、市城市规划局提供的地下综合管线图及道路断面图。

二、应遵守的有关设计、施工、验收规范1、《城镇燃气设计规范》(GB50028-2006)2、《城镇燃气输配工程施工及验收规范》(CJJ33-2005)3、《聚乙烯燃气管道工程技术规程》(CJJ63-2008)4、《燃气用埋地聚乙烯(PE)管道系统第1部分:管材》(GB15558.1-2003)5、《燃气用埋地聚乙烯(PE)管道系统第2部分:管件》(GB15558.2-2005)6、《辐射交联聚乙烯热收缩带》(SY/T4054-2003)7、《燃气用聚乙烯管道焊接技术规则》(TSG D2002-2006)8、《城市燃气输配及应用工程技术规定设计篇》(广州燃气集团有限公司企业标准JS L 002--2009))9、《燃气聚乙烯管道焊接技术暂行规定》(广州燃气集团有限公司企业标准JS I 002--2009)三、设计范围及概况1、管线范围:2、路由:3、与已设计或施工的主干管的连接:四、有关工艺设计参数:1、设计压力:中压燃气管道设计压力:0.4MPa(表压、以下同)。

2、设计埋深:本管线沿途一般埋深1.1米,最深处埋深1.5米,最浅处埋深0.9米。

3、设计管径:XX4、设计长度:总长米,其中支管长米。

5、阀门:采用埋地聚乙烯阀门,共计X个,具体规格为:De160为x个、De90 为X个。

6、附属设备:埋地聚乙烯凝水缸:无。

7、管材、管件:聚乙烯燃气管道及管件全部采用高密度聚乙烯管(HDPE,PE100级) 。

管材、管件颜色选择橙色,管材、管件均应符合国家现行有关标准并应具备出厂合格证。

管材、管件公差一律采用精公差等级(B级)。

燃气设计说明书(1)

燃气设计说明书(1)

设计说明书一. 设计题目:某开发区燃气输配管网设计 二. 设计目的燃气输配课程设计是建筑环境与设备工程专业学生在学习完《燃气输配》后的一次综合训练,其目的是让学生掌握城市燃气管网的设计方法,了解设计流程,熟悉设计手册、图集、设计规范、设备样本的使用方法。

通过该课程设计进一步掌握燃气输配工程的专业知识,深入了解燃气所需流量计算,燃气分配管网计算流量计算,水力计算,环网平差计算的具体方法,学会绘制设计图纸,编制设计说明就算书,从而达到具有结合工程实际进行燃气输配系统设计的能力。

三.设计任务根据某开发区基础资料设计该城市燃气输配管网工程,内容包括燃气中压管道的布线、平差及水力计算。

四.设计原始资料1.某开发区规划总平面图2.设计原始资料某开发区地处云南省西南部,位于东经103,05,北纬26,25,距昆明市330公里。

2.1城市居民人口数及建筑物情况该城镇规模5万人,人口密度400人/公顷,人民生活消费水平中等。

该城镇海拔高度1700-1850 2.3气象资料2.4城市燃气有关参数 2.5燃气用户资料五.燃气性能参数(表)1、 天然气的平均分子量:燃气是多组分的混合物,不能用一个分子是来表示。

通常将燃气的总质量与燃气的摩尔数之比称为燃气的平均分子量。

混合气体的平均分子量可按下式计算: 混合气体的平均分子量等于各组分的分子量之和,即)..........(10012211n n M y M y M y M +++⨯=式中——M :混合气体平均分子量;y 1、y 2、…y n :各单一气体容积成分(%); M 1、M 2、…M n :各单一气体分子量故 )..........(10012211n n M y M y M y M +++⨯==1001⨯(96⨯16.0430+30.0700⨯0.016+44.0970⨯0.0035+58.1240⨯0.003+28.0104⨯0.0015 +44.0098⨯0.0095+28.0134⨯0.004+2.016⨯0.0025)=16.7883(kmol m 3)2、 天然气的摩尔容积:混合气体的摩尔容积等于各组分的摩尔容积之和,即)..........(10012211mn n m m m v y v y v y V +++⨯=式中——m V :混合气体平均摩尔容积,m 3/kmol ;y 1、y 2、…y n :各单一气体容积成分(%); Vm 1、Vm 2、…Vm n :各单一气体摩尔容积m 3/kmol 故 )..........(10012211mn n m m m v y v y v y V +++⨯==1001⨯(96⨯22.3621+22.1872⨯0.016+21.9362⨯0.0035+21.5036⨯0.003+22.3984⨯0.0015 +22.2601⨯0.0095+22.403⨯0.004+22.427⨯0.0025)= 22.3546(kmol m 3)3.天然气的平均密度:单位体积的燃气所具有的质量称为燃气的平均密度。

燃气工程设计技术手册

燃气工程设计技术手册

燃气管道工程技术手册(2009年版)前言为了保证设计人员的设计能力和设计水平,满足我院业务发展的需要,同时为了统一本院设计标准、规范设计内容,提高整体设计质量和工作效率特制定本手册.本手册的编制是本着贯彻国家和地方有关方针、政策、法律、法规和强制性标准,有利于我院技术进步的原则,积极采用推荐国家强制性标准和行业标准。

在严格执行现行国家及行业标准的基础上,本手册意在为设计人员提供更多必要的设计参数,在保证设计施工图的合理性、降低消耗、减少浪费方面起到一定的作用。

同时结合公司发展方向,广泛征求了相关人员的意见,进行整理、分析,力求使手册更具有实用性、合理性和指导性。

此次本手册的内容主要包括了城镇中低压燃气管网、城市居民用户、商业用户及工业用户燃气工程等常规业务的设计基本知识和相关技术要求。

手册中引用了大量国家和行业标准的有关内容,这些标准、规范在引用时应注意当前的有效版本,引用的有关内容将随着标准的修订而被修改,均以最新的标准版本为准.由于各相目公司遍布全国各地,各地区的情况和习惯做法又千差万别,所以设计人员应在严格遵守国家及行业标准、规范的前提下,对手册的内容灵活运用。

在手册执行的过程中,我们诚恳地希望大家将遇到的问题及时反馈给设计分院,以便使手册的内容得到不断的补充、修改和完善.目录第一章基本规定3第一节绘图基本要求及设计图例3一、燃气专业制图的一般规定3三、燃气专业设计制图标准4四、燃气专业设计图例见附录一。

错误!未定义书签。

第二节燃气管道施工图设计文件7一、设计文件组成:7二、设计文件内容:7三、填写的几点要求:8四、施工图上的说明内容:8五、设计文件的格式规定:8第三节常用技术标准8一、国家标准8二、行业标准12三、标准应用:14第二章燃气管道施工图设计15第一节设计需收集的资料15一、室内燃气管道施工图设计需收集的资料15二、室外燃气管道施工图设计需收集的资料15三、调压器室燃气管道施工图设计需收集的资料16四、锅炉房(直燃机)燃气管道施工图设计需收集的资料16五、燃气管道跨越工程支撑设计需收集的资料(工艺专业提供给结构专业)17第二节管材及附件的选用17一、室内燃气管道的管材及管件选用17二、室外燃气管道的管材及管件选用18三、聚乙烯管材、管件的使用规定18四、穿跨越工程管材的选用19第三节设计参数及计算方法20一、燃气小时计算流量的确定20二、燃气管道摩擦阻力计算22三、低压燃气管网压降及压降分配24四、常用燃气管道规格的计算24第四节施工图设计要点28一、室内燃气管道工程施工图设计要点:28(一)管线位置28(二)阀门位置28(三)活接头位置29(四)套管的设置29(五)管卡或支架(托架)的设置29(六)燃气表的安装29(七)燃气燃烧器具的安装29(八)对燃具给排气设施和排烟设施的安装要求30(九)商业用户、工业企业设计要点31(十)锅炉房(直燃机)燃气管道设计要点31(十一)对于高层建筑的室内燃气管道系统应考虑的问题:32(十二)特殊场所安装燃气设施的要求:33(十三)燃气管道及设备的防雷、防静电设计应符合下列要求:34 (十四)室内燃气管道施工图需要注意的事项有:35二、室外燃气管道工程施工图设计要点:36(一)高、中压管线的平面布置原则36(二)高压管道设计需注意的事项:37(三)中压管道设计需注意的事项:38(四)低压管网的平面布置原则39(五)中、低压庭院管网设计应注意的几点:39(六)设计室外架空燃气管道应注意的几点:41(七)管道的纵断面布置原则42三、调压室燃气管道施工图设计要点:42第五节主要设备的选用和安装43一、燃气计量表43(一)燃气计量装置选型的基本原则43(二)燃气计量表装置的设置要求44(三)燃气表安装位置确定44(四)燃气表的保护装置45(五)燃气表的安装场所45二、调压装置的安装46(一)调压装置的选择原则46(二)调压装置的设置要求46(三)调压装置的工作环境46(四)调压器的安装调试应按照设备说明书和有关要求进行。

燃气设计说明书

燃气设计说明书

燃气设计说明书燃气设计说明书1.引言本燃气设计说明书为设计人员提供了有关燃气系统设计的详细信息和指导。

本文档旨在确保燃气系统设计安全可靠,符合相关法规和标准。

2.设计目标本设计说明书的目标是确保燃气系统满足以下要求:- 安全性:确保燃气系统的操作安全,防止燃气泄漏和爆炸事故。

- 可靠性:确保燃气系统可靠运行,提供稳定的燃气供应。

- 节能性:考虑节能设备和措施,减少燃气能源的消耗。

- 可维护性:设计易于维护和检修的燃气系统,以确保其长期运行。

3.设计依据本燃气设计说明书的设计依据包括但不限于以下标准和法规:- 国家燃气工程设计规范;- 国家燃气工程安全技术规范;- 当地燃气管道规划和设计标准;- 相关法律法规和安全规定。

4.系统概述本章节将对燃气系统的总体结构和功能进行详细描述,包括燃气供应来源、燃气系统组成部分以及系统的流程和关键设备。

5.燃气设备选择与布置在本章节中,将详细介绍各种燃气设备的选择原则和关键参数,以及不同设备的布置要求和安全间距。

6.燃气管道设计本章节将详细说明燃气管道及其附件的设计方法和要求,包括管道材料选择、管道布置和支撑方式、管道直径计算等。

7.燃气安全设施设计在本章节中,将介绍各种燃气安全设施的设计原则和要求,包括燃气泄漏报警系统、燃气泄漏自动切断阀、燃气防爆装置等。

8.燃气系统通风设计本章节将详细阐述燃气系统的通风设计,包括通风设备的选择和布置,通风量的计算和通风口的设置要求等。

9.燃气系统操作与维护在本章节中,将提供关于燃气系统的操作和维护指导,包括操作规程、维护计划和常见故障处理方法等。

10.附件本文档包含以下附件:- 燃气系统布局图纸- 燃气管道施工图纸- 燃气设备技术参数表- 燃气安全设施布置图纸法律名词及注释:- 燃气工程设计规范:指国家相关部门发布的适用于燃气系统设计的标准文件。

- 燃气工程安全技术规范:指国家相关部门发布的适用于燃气系统安全设计的技术规范。

中压燃气管道施工技术要求(最新版)

中压燃气管道施工技术要求(最新版)

中压燃气管道施工技术要求(最新版)Technical safety means that the pursuit of technology should also include ensuring that peoplemake mistakes( 安全技术 )单位:_________________________姓名:_________________________日期:_________________________精品文档 / Word文档 / 文字可改中压燃气管道施工技术要求(最新版)1编制说明中压管道设计压力0.4MPa,管材为聚乙烯和钢骨架聚乙烯复合管。

1.2本技术要求是对所采用规范的补充说明。

除本技术要求外,均按《城镇燃气输配工程施工及验收规范》中的有关条款执行。

本技术要求必须下发到每个参与施工的施工单位。

1.3采用的标准和规范1)《城镇燃气设计规范》GB50028-93(2002年版);2)《城镇燃气输配工程施工及验收规范》CJJ33-2005);3)《建筑设计防火规范》GB16-87(2002年版);4)《原油和天然气输送管道穿跨越工程设计规范穿越工程》SY/T0015.1-98;5)《石油天然气输送管道穿跨越工程施工及验收规范》SY/T4079-95;6)《埋地用钢骨架聚乙烯复合管燃气管道工程技术规程》CECS131:2002;7)《燃气用埋地聚乙烯(PE)管道系统第1部分:管材GB15558.1-2003;8)《聚乙烯燃气管道工程技术规定》CJJ63-95;9)《燃气用埋地孔网钢带聚乙烯复合管》CJ/T182-2003;10)《燃气用钢骨架聚乙烯塑料复合管件》CJ/T126-2000;11)《给排水管道工程施工及验收规范》GB50268;12)《钢制法兰尺寸》GB/T9113;13)《关于处理石油管道和天然气管道与公路相互关系的若干规定》(试行)(78)交公路字698号,(78)油化管道字452号)。

燃气设计说明书

燃气设计说明书
摘 要
燃气是指可以作为燃料的气体, 它通常是以可燃气体为主要成分的多组分混合气体。 新技术的发展使开拓燃气新的应用领域成为可能。在燃气工业史上,一次又一次的技术 革新为燃气使用的几个主要方面带来了重要的变化。最为明显的变化就是把燃气的主要 用途从用于照明转为厨房烹饪,又从烹饪转向取暖。本设计中燃气的主要用途有烹饪和 取暖两方面。 本工程为郑州市北辰小区天燃气管道设计,该设计采用纯天然气为气源。根据小区 规模和布局,合理规范设地设计管线,使施工便利性和经济性最大化。本设计的主要内容 还包括:气源性质计算,庭院燃气管网和室内燃气管道的水力计算,施工图设计,管道 的选材、施工、防腐和验收等。设计具有一定的技术性和经济性。
关键词:庭院燃气管道,室内燃e is the gas used as fuel, which is usually a multi-component gas mixture of combustible gas as its main components. New technologies introduce the possibility of whole new areas of gas consumption. In the history of gas industry, technical change has from time to time led to important shifts in the main sectors of consumption-the most obvious of which have been the changes in the principal uses of gas from lighting to cooking and from cooking to heating. The gas’s main purpose of this design have two hands, and is cooking and heating. This engineering is ZhenZhou Ben Chen district gas pipeline design. According to Residential quarters size and layout, Reasonable standard set design of pipeline. The construction convenience and the efficiency maximization. The design of the main content includes: air properties calculation, the courtyard gas network and indoor gas pipeline hydraulic calculation and pipe materials, construction, anti-corrosion and acceptance, etc. The design is technical and economic in some degree.

燃气规划说明范例

燃气规划说明范例

前言燃气供应设施是城市重要的市政基础设施,也是城市现代化的重要标志之一。

近年来,某城市燃气事业得到了快速发展,气源供应渠道有所拓宽。

尤其天然气资源广泛充分的利用,促进了某城市县国民经济和社会事业的快速发展,对提高城市化、现代化水平,起到了重要作用。

目前,某城市县实现了管道天然气的供应,城区采用中压一级主干管网系统。

但是城区天然气管道的普及率比较低,在天然气气源供应方面存在缺口,城乡供气设施存在很大差异,城镇燃气普及水平参差不齐,不能完全适应国民经济和社会发展的需要。

部分居民及商业、工业用户的日常燃料仍采用燃煤或重油等高污染的燃料,随着工业的快速发展和旅游业的兴起,环境保护的压力越来越大。

改善能源结构,实现城区燃气管道化,已成为某城市县城区建设的当务之急,也是经济健康发展的必然途径。

从目前地区已建成的天然气输气管网布局来看,天然气可以调入某城市,为某城市县燃气事业发展提供了良好的机遇。

但是为了满足冬季最高月份高峰日负荷的应急供气需求,仍需进一步提前做许多相应工作。

另外城区CNG汽车加气供需矛盾日渐加大,CNG加气站建设没有专项规划遵循,选址落地存在困难,无法实现合理布局。

为解决上述问题,就需要统筹整合某城市县全县域燃气供需平衡及高效发展利用,对某城市县燃气需求总量和需求结构进行科学预测;需要统筹实施某城市县燃气基础设施建设,摆脱人为分割、地域分割,形成完善的管网系统及配套设施,达到资源共享,互相调剂的目的,保障城市管网安全运行。

需要对天然气加气站布局进行合理规划,做好近期与远期燃气工程的衔接。

I目录第1章绪论 (1)1.1规划背景 (1)1.2城市总体规划概况 (1)1.2.1 城市概况 (1)1.2.2 城市总体规划简介 (1)1.3规划范围 (2)1.4规划期限 (2)1.5规划依据和原则 (2)第2章天然气需求预测 (4)2.1城市能源供应和消费状况 (4)2.2某城市县天然气供应渠道 (4)2.3供气范围、供气对象及天然气的基本参数 (4)2.1.1供气范围 (4)2.1.2供气对象 (4)2.1.3基本参数 (4)2.2各类用户耗热定额 (5)2.2.1居民 (5)4.2.2商业用户 (6)4.2.3燃气汽车 (7)4.2.4工业 (7)4.2.5采暖用户 (8)4.2.6燃气空调用户 (8)4.3各类用户不均匀系数 (8)4.3.1居民和商业用户 (8)4.3.2燃气汽车 (9)4.3.3工业 (9)4.3.4采暖用户 (9)4.3.5燃气空调用户 (9)4.4天然气需求量预测 (10)-II-4.4.1城区天然气需求 (10)4.5天然气气量平衡及计算流量 (14)4.6天然气调峰储气量 (16)第3章燃气输配系统规划 (17)3.1城区供气方案规划 (17)3.1.1概述 (17)5.1.2管网压力级制选择 (17)5.1.3储气调峰方式选择 (18)5.1.4天然气供应应急措施 (19)5.2城区规划方案 (19)5.2.1天然气门站 (20)5.2.2.2中压管网规划 (20)第4章组织机构、劳动定员及后方设施 (25)9.1燃气企业运营模式 (25)9.2组织机构及劳动定员 (25)9.2.1组织机构 (25)9.2.2 劳动定员 (28)9.3后方设施 (29)第5章环境保护 (30)11.1本工程的主要污染源及其治理措施 (30)11.1.1 规划编制依据 (30)11.1.2主要污染源和主要污染物 (30)11.1.3防治措施 (31)11.2环保效益 (32)11.2.1 民用型煤替代环保效益 (32)11.2.2燃气汽车环保收益 (32)第6章消防与安全措施 (33)12.1工程概况及规划依据 (33)12.2站区总图布置及建筑消防 (33)12.3消防设计 (34)-III-12.4电气设计 (34)12.5运行管理及消防措施 (35)第7章职业安全卫生 (37)13.1 编制依据的主要标准、规范 (37)13.2 主要危害因素分析 (37)13.2.1生产危害因素 (37)13.2.2自然危害因素 (38)13.3 主要防范措施 (38)13.4 劳动安全卫生机构及设施 (39)-IV-第1章绪论1.1规划背景近几年,某城市县城市燃气事业得到了快速发展,气源供应渠道有所拓宽,天然气资源广泛而充分的利用,对促进某城市县国民经济和社会事业的快速发展,提高城市化、现代化水平,起到了重要作用。

市政中压燃气管道工程施工组织方案

市政中压燃气管道工程施工组织方案

道路市政中压燃气管道工程施工方案目录一、项目概况 (1)2. 编译依据 (1)三、施工准备 (1)1.工人 (1)二、技术准备 (1)3.材料准备 (2)4.工作条件 (2)4.工作方法 (2)一、操作方法及步骤.............................................................................................................................................. 二五、建设进度计划及保障措施 (3)(一)建设总体进展情况 (3)(二)施工进度表(图片:附最后一页) (3)6.平面布局 (3)七、质量保证措施 (3)(1) 项目质量目标 (3)(2) 质量保证体系和质量管理 (3)1.质量保证体系 (3)2.项目部质量管理机构设置 (3)(1) 质量保证措施 (3)1.施工过程中的质量控制 (4)八、确保安全措施 (4)(一)安全保障措施 (4)九、文明施工现场措施 (5)(一)文明工地措施 (5)2 ) 减少噪声干扰和环境污染的技术措施5.................................................................................................... 图.. (7)一、项目概况本项目为***路市政中压燃气管道工程。

该项目的设计终点如图所示。

本项目输气管道采用定向钻挖法铺设。

工程总长598米,主管道直径为dn160、dn110,设计压力0.4MPa,工作压力<0.4MPa,属于GB1级压力管道。

本工程管道设计压力为0.4MPa,介质压力为A级,工作压力小于0.4MPa。

2. 编译依据《城市燃气设计规范》GB50028-2006《城市燃气输配工程施工及验收规范》CJJ33-2005《油气管道穿越工程施工规范》(GB50424-2007)《燃气用埋地聚乙烯PE管道系统第1部分:管道》(GB15558.1-2003)《燃气用埋地聚乙烯PE管道系统第2部分:管件》(GB15558.2-2005)《聚乙烯燃气管道工程技术规程》(CJJ 63-2008)《燃气用聚乙烯管道焊接技术规程》(TSG D2002-2006)《城镇燃气技术规范》(GB50494-2009)三、施工准备1. 工人2、技术准备3.2.1熟悉图纸和工作指导书的编写。

燃气管道工程设计完全手册(doc 83页)

燃气管道工程设计完全手册(doc 83页)

燃气管道工程设计完全手册(doc 83页)目录第一章燃气设计基本规定 (1)第一节绘图基本要求及设计图例 (1)1.燃气专业制图的一般规定 (1)2.设计文件标识 (3)3.常用绘图比例 (5)4.燃气专业设计制图标准 (6)5.设计图例 (12)第二节燃气管道施工图设计文件组成 (12)1.燃气管道施工图设计文件组成 (12)2.燃气管道施工图设计文件组成的内容 (13)3.对设计文件内容填写的几点要求 (14)4.施工图上的说明内容 (14)5.设计文件的格式规定 (15)第三节燃气管道施工图设计常用技术标准 (15)1.国家标准 (15)2.行业标准 (23)3.参考资料 (26)第二章燃气管道施工图设计 (29)第一节施工图设计需收集的资料 (29)8.低压燃气管道单位长度的摩擦阻力损失计算: (60)9.室外常用管道规格计算: (62)第四节施工图设计要点 (63)1.室内燃气管道工程施工图设计要点: (63)2.室外燃气管道工程施工图设计要点: (81)3.调压室燃气管道施工图设计要点: (90)4锅炉房燃气管道工程施工图设计要点: (93)第五节穿跨越工程设计要点 (94)一、管道穿越工程 (94)二、管道跨越工程 (113)第六节管材及附件的选用 (123)1.室内燃气管道的管材及管件选用. 1232.室外燃气管道的管材及管件选用. 1243.穿跨越工程管材的选用见第五节。

(125)4.阀门的选用 (125)5.补偿器的选用 (125)6.凝水缸的选用原则 (125)第七节调压装置 (126)1.调压器的作用和性能参数 (126)2.调压器的选择 (133)3.调压箱(站)设计说明 (133)4.调压装置的选择 (136)6. 调压站(箱)的工艺设计 (140)7.调压器的安装调试应按照设备说明书和有关要求进行。

(142)8.其它有关调压站的设计要求见《城镇燃气设计规范》。

(142)第八节计量装置 (142)1.城市燃气流量计的类型及特点 (142)2.燃气计量装置的选型 (149)3.燃气计量装置设置要求 (155)4.燃气表安装位置确定 (155)5.燃气表的保护装置 (157)6.燃气表的安装场所: (158)第九节法兰、垫片、紧固件 (159)室内天然气管道施工图设计总说明 (204)室外天然气管道施工图设计总说明 (213)本手册引用标准:GB50028—93 城镇燃气设计规范(2002年版)GB16914—1997 燃气燃烧器具安全技术通则GB50235—97 工业金属管道工程施工及验收规范GB50236 现场设备、工业管道焊接工程施工及验收规范GB16802 城镇燃气调压器GB3323—87 钢融化焊对接接头射线照相和质量分级GB50251—94 输气管道工程设计规范GB50041—92 锅炉房设计规范CJJ12—99 家用燃气燃烧器具安装及验收规程CJJ63—95 聚乙烯燃气管道工程技术规程CJJ94—2003 城镇燃气室内工程施工及验收规范CJJ33—89 城镇燃气管道施工及验收规范SY/T0015.1—98 原油和天然气输送管道穿跨越工程设计规范穿越工程SY/T0015.2 —98 原油和天然气输送管道穿跨越工程设计规范跨越工程SY0470 石油天然气管道跨越工程施工及验收规范SY/T4079—95 石油天然气管道穿越工程施工及验收规范第一章燃气设计基本规定第一节绘图基本要求及设计图例1.燃气专业制图的一般规定1.1设计图纸幅面及尺寸1.1.1标准图幅图纸按尺寸(图幅)大小分为五个规格,分别为A0、A1、A2、A3、A4,尺寸大小见表-1。

中压燃气管道设计说明

中压燃气管道设计说明

中压燃气管道设计说明燃气作为一种常见的能源供应形式,具有清洁、高效、安全等特点,被广泛应用于居民生活、工业生产和商业用途中。

而中压燃气管道系统作为将燃气输送到用户端的重要环节,必须合理设计以确保燃气供应的安全和稳定。

本文将对中压燃气管道设计进行详细说明,主要包括设计原则、管道选材、布置形式等方面的内容。

一、设计原则1.遵循相关法律法规:设计过程中需严格遵循国家和地方的相关法律法规,确保设计符合规定要求。

2.安全性考虑:管道设计应考虑管道的安全性,必须满足燃气流量和压力下的强度要求,确保能够承受异常情况和突发事件的冲击。

3.抗震设计:中压燃气管道应采用抗震设计,以应对地震或其他地质灾害可能产生的影响。

4.系统完整性:中压燃气管道系统应设计为一个完整的系统,包括输气站、中间站和用户端的连接,确保整个系统的连续性和可靠性。

二、管道选材1.强度要求:中压燃气管道系统应选用抗拉、抗压、抗弯等力学性能良好的材料,确保能够承受燃气压力和温度的要求。

2.耐腐蚀性:由于管道内输送的是燃气,对管道材料的耐腐蚀性有较高要求,常用的管道材料有无缝钢管、环氧树脂涂层钢管等。

3.寿命和使用期限:管道的使用寿命和使用期限要长,确保长期安全可靠的燃气供应。

三、布置形式1.地下敷设:地下敷设是常用的一种布置形式,可减少管道对土地使用的影响,减少施工噪音和视觉污染。

在地下敷设管道时,需要注意地下管道的埋深和保护措施,确保地下管道的安全和可靠运行。

2.地上敷设:地上敷设适用于临时用气或升级改造工程,可以减少施工难度和成本。

但地上敷设的管道易受到外界环境的影响,需要采取适当的保护措施,如设置防腐层和防护罩等。

中压燃气管道设计的要点和注意事项还有很多,需要根据具体的项目要求进行细化和调整。

设计人员在设计时需全面考虑各种因素,确保不仅满足燃气供应的基本要求,还能够应对各种异常情况和突发事件,确保燃气供应的安全和可靠。

设计过程中还需充分沟通和协调与施工方和监理方,以确保设计方案的可行性和实施效果。

燃气管网设计说明书

燃气管网设计说明书

09级建筑环境与设备工程专业《燃气输配》课程设计说明书设计题目衡阳县天然气输配管网设计专业 09级建筑环境与设备工程学生姓名王金刚学号************指导教师管延文老师目录一、设计资料 (3)1.1衡阳县相关资料 (3)1.2天然气气源 (3)1.3我国一些地区和城市的居民生活用气量指标 (4)二、负荷计算 (5)2.1城市燃气总年用量计算 (5)2.2确定各类用户用气高峰系数 (7)2.3计算月平均日和小时计算流量 (8)三、管道布置 (10)3.1、管网系统选择 (10)3.2、中压管网布置原则 (11)3.3、管道布置及管网规划图 (11)四、管网水力计算 (12)4.1、管道的途泄流量 (12)4.2、确定零点 (12)4.3、转输流量的计算 (12)4.4、管道的计算流量 (12)4.5、计算过程 (12)4.6,管网平差计算 (15)五、储气容积计算 (17)5.1、用气量的储气容积 (17)5.2、确定储气罐的实际容积 (18)六、燃气输配课程设计体会 (19)参考文献 (20)附录 (21)燃气输配课程设计说明书设计题目:衡阳县天然气输配管道设计一、设计资料◆1.1、衡阳县相关资料:供气区面积为:3.5平方公里人口密度为:4万人/平方公里属于南方地区无采暖考虑。

◆1.2、天然气气源:中原油田液化天然气特性参数表1项目参数取值组分,体积百分比(%)CH495.857C2H62.936C3H80.733iC4H100.105nC4H100.201iC5H120.031nC5H120.037N20.085 其它0.015分子量,kg/kmol 17.3气化温度,℃(0.3MPa)-161.5临界温度,℃-82.3临界压力,kg/cm245.8液态密度,kg/m3(15.5℃)460气态密度,kg/Nm30.754液态/气态膨胀系数,m3/m3LNG(20℃)610低热值,MJ/Nm3(kcal/Nm3)36.15(8641)运动粘度, m2/s 12.07×10-6华白指数,MJ/Nm344.94燃烧势45.18爆炸极限5%~15%◆1.3、我国一些地区和城市的居民生活用气量指标:城镇居民生活用气量指标[MJ/(人·年)] 表2二、负荷计算◆2.1、城市燃气总年用量计算2.1.1居民生活年用气量居民生活的燃气用量和燃气用具的配置、气候条件、有无集中热水供应等许多因素有关,很难精确估计,通常根据实际统计资料分析而得的用气定额来计算。

燃气设计识图讲义

燃气设计识图讲义
燃气设计识图
目录
图线绘制规定 比例的表示 尺寸标注 管径和管道坡度 标高 常见不同用途管道图例 阀门、管件符号 庭院工程制图规定
图线绘制规定
图线的粗实线宽度为b,宜从下列线宽系列中选取:2.0、1.4、1.0、0.7 、0.5、0.35mm。每个图样,应根据复杂程度与比例大小,先选定基 本线宽b,再选用表2.1中相应的线宽组。
常规项目常用比例 1. 小区庭院管网:1:1000,1:500,1:200 2. 室内管道平面布置图:1:100 3. 系统图、剖面图:1:50 4. 室外中低压管道纵断面图:横向:1:1000,1:500;
纵向:1:100,1:50
尺寸标注
尺寸标注应包括尺寸界线,尺寸线、尺寸起止符和 尺寸数字。尺寸宜标注在图形轮廓线以外
系统图中管道标高
常见不同用途管道图例
序号 1
名称 管道加套管
图形符号
2
软管、挠性管
3
报废管
4
管道重叠
5
管线交叉
管道穿墙
6
管道穿楼板
阀门、管件符号
序号
名称
图例
1
球阀
2
Y型过滤器
3
筒形过滤器
4
调压箱
5 钢塑过渡接头
6
同心异径管
7
偏心异径管
8
法兰
管线安装设计常用画法
管道转向的画法
管道分支的画法
平面密集管道交叉、遮挡的打断画法
户外挂表
庭院工程制图规定
图线绘制规定表1常用线型画法及用途名称线型线宽用途示例粗实线b表示新建架空低压管道粗虚线b表示新建埋地低压管道粗单点划线b表示新建埋地中压管道粗双点划线b表示新建架空中压管道细实线025b1可见建构筑物道路河流地形地貌等的轮廓线2尺寸线尺寸界线3设备及附件等的图形符号4设备零部件及管路附件等的编号引出线5较小图形中心线中实线05b表示已建架空低压管道中虚线05b表示已建埋地低压管道中单点划线05b表示已建埋地中压管道中双点划线05b表示已建架空中压管道比例的表示?比例一般采用阿拉伯数字表示
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

XXX路燃气管道工程
一.设计依据
1.设计委托书。

2.委托方提供1:500道路施工带状图<<XXXXXXXXXXX>>及其它图纸资料。

3.规划部门批准的燃气管道规划红线。

4.《城镇燃气设计规范》GB50028-2006;
5.《城镇燃气输配工程施工及验收规范》CJJ33-2005/J404-2005;
6.《聚乙烯燃气管道工程技术规程》CJJ63-2008;
7.《燃气用埋地聚乙烯(PE)管道系统第1部分:管材》GB ;
8.《燃气用埋地聚乙烯(PE)客道系统第2部分:管件》GB ;
9.《燃气用埋地聚乙烯(PE)管道系统第3部分:阀门》GB ;
10.该路段道路已形成,其基础强度满足燃气管道的敷设要求,故不另作地质勘察报告。

二.工程概况
本工程燃气中压管道全长XXX米,道路桩号XXXXX~XXXXX,燃气管道桩号0+000相当于道路桩号X+XXXXX,预留支管XX处,其中横穿道路XX处。

规划红线位置:在XX X路以北距道路中心线10米处。

三.输送介质及性质
输送介质:天然气,密度: Kg/Nm³;低热值:8000Kcal/Nm³(20℃);
华白指数:Nm³。

四.设计压力
设计压力:。

五.管材及管件
本工程燃气管道选用燃气用埋地聚乙烯管道,聚乙烯管材及管件均采用SDR11系列,管材应符合《燃气用埋地聚乙烯管材》的规定,管件应符合《燃气用埋地聚乙烯管件》的规定。

六.管道的安装
1)聚乙烯管采用热熔对接方式连接。

2)热熔连接的焊接接头连接完成后,应进行100%外观检验及10%翻边切除检验,并应符合《规程》CJJ63-2008的要求。

七.防腐
聚乙烯管道本身具有耐腐蚀性能,无需外防腐层。

八.管道敷设
1.沟槽开挖、基础处理.回填等土方工程施工要求应按《规范》CJJ33-2005。

2.本工程管道净埋深不小于米,施工时应保证地下燃气管道与相邻管道及建、构筑物之间
的水平和垂直距离不应小于《规范》GB50028-2006中条之规定。

3.在管道正上方距管顶0.3m-0.5m处沿管线连续敷设警示带,聚乙烯管还应在管顶同时随
管道走向敷设示踪线,示踪线的接头应有良好的导电性。

4.管道焊接完成,经检验合格后回填,聚乙烯管道四周米范围内采用细土回填并人工夯实,
密实度不低于90%,其他部位密实度应符合相应地面对密实度的要求。

4.该路段道路已形成,其基础强度满足燃气管道的敷设要求,施工中如遇特殊情况,请及
时通知设计人员到现场,对基础进行处理。

九.阀门安装
1.阀门安装前应按设计要求核对型号、公称直径、公称压力,检查阀体、零件等有无砂眼、裂纹等。

2.阀门安装前应按其产品标准要求单独进行强度和严密性试验。

十.吹扫及试验
1.管道安装完毕后,应进行吹扫。

2.管道吹扫合格后方可进行强度和严密性试验,试验介质为空气或惰性气体。

.
3.强度试验
1)试验压力为。

2)埋地管道的强度试验宜在回填至管顶上方0.5m以上后进行。

3)强度试验稳压时间为1小时,仔细观察不少于30min, 无压降为合格。

4.严密性试验
1)试验压力为。

2)埋地管道的严密性试验宜在管线全线回填后进行。

3)严密性试验的稳压时间应为24小时,以修正压力降小于133Pa为合格。

十一.若施工中遇到其他技术问题,请及时联系设计人员。

相关文档