GB16808可燃气体报警控制器2018新版

合集下载

液化天然气瓶组气化站隐患排查清单检查依据目录

液化天然气瓶组气化站隐患排查清单检查依据目录
CJJ/T 148-2010《城镇燃气加臭技术规程》第3.2.1条、第3.2.2条
2022.002.07.013
应急救援预案
无应急救援预案(含与实际不符、模板化、照抄照搬、未修订等)。
《中华人民共和国安全生产法》第八十一条
《生产安全事故应急条例》第五条、第六条
《生产安全事故应急预案管理办法》第十二条、第十三条、第十四条、第十五条、第十六条、第十八条、第三十五条、第三十六条、第三十七条
GB 55009-2021《燃气工程项目规范》第2.3.2条
2022.002.07.028
运行、维护和抢修人员
未按求配备运行、维护和抢修人员。
《燃气经营许可管理办法》第五条(六)项
2022.002.07.029
主要人、董事长、经理)未经专业培训并考核合格。
《中华人民共和国安全生产法》第八十二条
《生产安全事故应急条例》第十条、第十一条
《生产安全事故应急预案管理办法》第三十一条
《北京市生产经营单位安全生产主体责任规定》第三十一条
GB 55009-2021《燃气工程项目规范》第2.3.4条
2022.002.07.018
应急演练
未按规定定期组织应急演练或演练流于形式。
《生产经营单位安全培训规定》第二十二条
《北京市生产经营单位安全生产主体责任规定》第十七条、第十八条
CJJ 51-2016《城镇燃气设施运行、维护和抢修安全技术规程》第4章、第8.2.1条
CJJ/T 215-2014《城镇燃气管网泄漏检测技术规程》第4.0.7条、第6.0.1条、第6.0.2条、第6.0.3条
设备设施类
LNG钢瓶
设置在建筑物内。
GB 55009-2021《燃气工程项目规范》第4.3.1条

GB可燃气体报警控制器新版

GB可燃气体报警控制器新版

GB16808可燃气体报警控制器1、范围本标准规定了可燃气体报警控制器的范围、分类、要求、试验、检验规则、标志和便用说明书。

本标准适用于一般工业与民用建筑中安装使用的可燃气体报警控制器(以下简称控制器),其它环境中安装的具有特殊性能的控制器,除特殊要求应由有关标准另行规定外,亦应执行本标准。

2、规范性引用文件下列文件对于本文件的应用是必不可少的。

凡是注日期的引用文件.仅所注日期的版本适用于本文件.凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。

GB4706.1-2005家用和类似用途电器的安全第l部分:通用要求GB/T9969工业产品使用说明书总则GB 12978消防电子产品检验规则GB 15322可燃气体探测器GB 16838消防电子产品环境试验方法及严酷等级GB/T 17626.2电磁兼容试验和测量技术静电放电抗扰度试验GB/T 17626.3电磁兼容试验和测量技术射频电磁场辐射抗扰度试验G8/T17626.4电磁兼容试验和测量技术电快速瞬变脉冲群抗扰度试验GB/T17626.5电磁兼容试验和测量技术浪涌(冲击)抗扰度试验GB/T17626.6电磁兼容试验和测量技术射频场感应的传导骚扰抗扰度试验GB/T17626.11电磁兼容试验和测量技术电压暂降、短时中断和电压变化的抗扰度试验3分类3.1控制器按工作方式分为:a)总线制;b)多线制。

3.2控制器按便用环境分为:a)室内使用型;b)宝外使用型。

3.3控制器按应用方式分为:a)独立型(不具有向其它控制器传递信息功能的控制器):b)区域型(具有向其它控制器传递信息功能的控制器):c)集中型(具有接收其它控制器传递的信息并集中显示功能的控制器).4术语和定义4.1屏蔽状态disabled condition控侧器在屏蔽功能启动后所处的状态。

4.2监管信号supervisory signal控制器监视的与其连接设备发出的除可燃气体报警、故障信号之外的其它输入信号.4.3监管报警状态supervisory signal condition控制器发出监管报警信号时所处的状态。

【VIP专享】GB16808-1997可燃气体报警控制器技术要求和试验方法

【VIP专享】GB16808-1997可燃气体报警控制器技术要求和试验方法
弦 )
GB 广I 6 113一1995 电磁干扰和抗扰度测量设备规范
3 技术要求
3.1 主电源如为交流供电,应采用220V ,50H z,
32 基本功能要求
3.2.1 能为可燃气体探测器和所连接的其他部件供电 3.22 fit直接或间接地接收来白可燃气体探测器及其他报警触发器件的报警信号,发It声、光报警信 号,指示报警部位并予以保持 声报警信号应能手动消除,再次有报警信号输入时应能发出报褥信号 3.2-3 其有可燃气体浓度显示的可燃气体报警控制器应能显示当前可燃气体浓度值,其全量程指示偏
2 弓}用标准
[.-列 标 准 所包含的条文,通过在本标准中引用而构成为本标准的条文。本标准出版时,所示版本均 为有效。所有标准都会被修订,使用本标准的各方应探讨使用下列标准最新版本的可能性。
CUB2 423.1- 89 电1电子产品基本环境试验规程 试验A:低温试验方法 GB2 423.2-89 电_L:电子产品基本环境试验规程 试验 B;高温试验方法 GB /1 '2 423.3- 93 电」_电子产品基本环境试验规程 试验Ca;恒定湿热试验方法 GB /T 2 423.5--1995 电工电子产品环境试验 第 2部分:试验方法 试验Ea和导则:冲击 GB /T 2 423.10 -1995 电工电子产品环境试验 第2部分:试验方法 试验Fc和导则:振动(正
续正常工作 2h: a) 可 燃 气体报警控制器容量不超过 4个构成单独部位号的回路(以下称回路)时,所有回路均处于
报警状态 ;
b) 可 燃 气体报警控制器容量超过 4个回路时,百分之二十的回路(不少于4回路,但不超过 10回
路)处 于报瓷状态 3.2.11 可燃气体报警控制器应备有用作控制自动消防设备或作其他用途的输出接点,其容量及参数 应在有关技术文件中说明,并保证在规定的范围内可靠动作。 3-2-12 采用数宇一字母显示的可燃气体报警控制器还应满足下列要求。

GB16808可燃气体报警控制器(2018年新版)

GB16808可燃气体报警控制器(2018年新版)

GB16808可燃气体报警控制器1、范围本标准规定了可燃气体报警控制器的范围、分类、要求、试验、检验规则、标志和便用说明书。

本标准适用于一般工业与民用建筑中安装使用的可燃气体报警控制器(以下简称控制器),其它环境中安装的具有特殊性能的控制器,除特殊要求应由有关标准另行规定外,亦应执行本标准。

2、规范性引用文件下列文件对于本文件的应用是必不可少的。

凡是注日期的引用文件.仅所注日期的版本适用于本文件.凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。

GB4706.1-2005家用和类似用途电器的安全第l部分:通用要求GB/T9969工业产品使用说明书总则GB 12978消防电子产品检验规则GB 15322可燃气体探测器GB 16838消防电子产品环境试验方法及严酷等级GB/T 17626.2电磁兼容试验和测量技术静电放电抗扰度试验GB/T 17626.3电磁兼容试验和测量技术射频电磁场辐射抗扰度试验G8/T17626.4电磁兼容试验和测量技术电快速瞬变脉冲群抗扰度试验GB/T17626.5电磁兼容试验和测量技术浪涌(冲击)抗扰度试验GB/T17626.6电磁兼容试验和测量技术射频场感应的传导骚扰抗扰度试验GB/T17626.11电磁兼容试验和测量技术电压暂降、短时中断和电压变化的抗扰度试验3分类3.1控制器按工作方式分为:a)总线制;b)多线制。

3.2控制器按便用环境分为:a)室内使用型;b)宝外使用型。

3.3控制器按应用方式分为:a)独立型(不具有向其它控制器传递信息功能的控制器):b)区域型(具有向其它控制器传递信息功能的控制器):c)集中型(具有接收其它控制器传递的信息并集中显示功能的控制器).4术语和定义4.1屏蔽状态disabled condition控侧器在屏蔽功能启动后所处的状态。

4.2监管信号supervisory signal控制器监视的与其连接设备发出的除可燃气体报警、故障信号之外的其它输入信号.4.3监管报警状态supervisory signal condition控制器发出监管报警信号时所处的状态。

建筑消防设施年度检测技术要求内容汇总

建筑消防设施年度检测技术要求内容汇总

建筑消防设施年度检测技术要求内容汇总一、一般要求严格按照消防法规和行业有关消防技术标准进行检测。

在受托检测期间投标方对所检测的消防设施和设备必须按照最初设计要求,并符合国家现行技术规范标准,但不限于此:(1)《火灾自动报警系统施工及验收标准》GB50166—2019(2)《火灾报警控制器标准》GB4717—2005(3)《自动喷水灭火系统设计规范》GB50084—2017(4)《自动喷水灭火系统施工及验收规范》GB50261—2017(5)《水喷雾灭火系统设计规范》GB50129—2014(6)《气体灭火系统施工要求及验收规范》GB50263—2007(7)《泡沫系统设计规范》GB50151-2010(8)《泡沫灭火系统施工及验收规范》50281—2006(9)《消防联动控制设备通用技术条件》GB16806—2006 (10)《可燃气体探测器技术要求和试验方法》GB15322—1994(11)《消防安全标志设置要求》GB15630—1995(12)《消防安全标志第 1 部分:标志》GB13495.1—2015(13)《消防应急照明和疏散指示系统》GB17945—2010 (14)《可燃气体报警控制器》GB 16808-2018(15)《消防控制室通用技术要求》GA767—2008(16)《建筑消防设施检测技术规程》GA503-2004(17)《建筑消防设施的维护管理》GB25201-2010(18)《自动喷水灭火系统第21部分:末端试水装置》GB5135.20-2011(19)《消防给水及消火栓系统技术规范》GB50974-2014 (20)《火灾自动报警系统施工验收规范》GB50116—2013 (21)《建筑设计防火规范》GB50016-2014(22)《建筑内部装修防火施工及验收规范》GB50354-20051、各消防设施的组件和设备应符合设计选型,并应具有出厂产品合格证,消防产品应符合法定市场准入的证明文件。

作业场所可燃气体检测报警设备设置标准

作业场所可燃气体检测报警设备设置标准

作业场所可燃气体检测报警设备设置标准在现代工业生产中,随着工艺的不断发展,作业场所存在着各种各样的安全隐患,其中一项重要的安全隐患就是可燃气体泄漏。

为了及时发现可燃气体泄漏并采取相应的措施,作业场所一般都需要设置可燃气体检测报警设备。

而对于这些设备的设置标准也是非常重要的,它直接关系到作业场所的安全生产。

在本文中,我将从深度和广度的角度,探讨作业场所可燃气体检测报警设备设置标准,并共享一些个人观点和理解。

一、作业场所可燃气体检测报警设备的基本概念作业场所可燃气体检测报警设备,顾名思义,是用来监测作业场所中可燃气体浓度的设备。

一旦检测到可燃气体超过设定的浓度阈值,设备就会发出声光报警信号,提醒相关人员并启动相应的应急措施。

这些设备通常包括传感器、控制器、显示屏和报警器等部件,其设置标准直接关系到设备的布局、区域划分和报警响应等方面。

二、作业场所可燃气体检测报警设备设置标准的要求1. 设备布局:根据作业场所的实际情况和可燃气体泄漏的可能位置,需要合理设置可燃气体检测报警设备的布局。

需要重点考虑如何最大限度地覆盖作业场所各个区域,并确保设备能够及时准确地监测到可燃气体的存在。

2. 区域划分:作业场所往往包括多个区域,而不同区域的可燃气体浓度可能存在差异。

需要根据不同区域的特点,合理划分监测区域,并设置相应的检测报警设备。

3. 报警响应:一旦检测到可燃气体浓度超过设定阈值,设备应能够及时、准确地发出报警信号,并启动相应的应急预案。

这包括设置报警信号的声音和亮度、报警信息的传输方式等方面。

三、作业场所可燃气体检测报警设备设置标准的个人观点和理解从我的个人观点来看,作业场所可燃气体检测报警设备的设置标准应该更加注重实际效果和可操作性。

设备的布局和区域划分应基于对作业场所的深入了解和分析,而非简单地按照标准进行设置。

在报警响应方面,需要考虑到人员疏散、应急救援等因素,以确保在发生事故时能够最大限度地保障人员的安全。

可燃气体报警控制器产品标准转换检验实施方案.

可燃气体报警控制器产品标准转换检验实施方案.

国家消防电子产品质量监督检验中心可燃气体报警控制器产品标准转换检验实施方案
根据全国消防标准化技术委员会第六分技术委员会文件《可燃气体报警控制器产品标准新旧版本比较说明》,在对可燃气体报警控制器产品进行型式认可标准转换检验时,如果可燃气体报警控制器产品无设计变更或仅针对新版标准与原标准不同的要求进行了设计变更,可以只进行新版标准新增的及与旧版标准不同的下列试验项目的检验:
1.主要部(器)件检查
2.可燃气体浓度显示功能试验
3.可燃气体报警功能试验
4.故障报警功能试验
5.屏蔽功能试验
6.自检功能试验
7.电源功能试验
8.射频场感应的传导骚扰抗扰度试验
9.静电放电抗扰度试验
10.浪涌(冲击)抗扰度试验
11.电压暂降、短时中断和电压变化的抗扰度试验
12.低温(运行)试验
国家消防电子产品质量监督检验中心
2009年10月14日。

FC18-操作手册

FC18-操作手册

FC18-操作手册JB-TGZL-FC18R 型火灾报警控制器(联动型)操作说明书目录第一章 系统简介···········································································································································3 1. 特点 ·····················································································································································3 2. 性能参数················································································································································4 3. 外形尺寸················································································································································5 4. 兼容设备目录··········································································································································5 5. 系统结构················································································································································6第二章 安 装··············································································································································8 1. 安装过程················································································································································8 2. 接线图···················································································································································9 3. 拨码开关设置········································································································································13第三章 操 作·············································································································································14 1. 界面显示··············································································································································14 2. 液晶窗口显示········································································································································16 3. 用户级别··············································································································································18 3.1 登录 ··············································································································································19 3.2 退出 ··············································································································································19 4. 状态类型··············································································································································20 5. 火警事件处理········································································································································22 6. 故障事件处理········································································································································23 7. 监管事件处理········································································································································24 8. 启动/反馈事件处理·································································································································25 9. 实时事件查询········································································································································26 10. 设备属性查询········································································································································27 11. 历史记录查询········································································································································28 12. 如何进行屏蔽/开放·································································································································29 13. 如何进行启动/停止·································································································································30 14. 如何进行测试/移动测试···························································································································31 15. 如何进行定位测试/定位恢复·····················································································································32 16. 如何设置蜂鸣器音量·······························································································································33 17. 如何设置登录时间··································································································································34 18. 如何设置移动测试时间····························································································································35 19. 如何设置 LCD 关闭时间 ··························································································································36 20. 如何设置时间········································································································································37 21. 如何进行系统检测··································································································································38 22. 如何保存配置········································································································································39 23. 如何修改参数········································································································································40 24. 如何新建/查看联动关系···························································································································41 25. 如何编辑/删除联动关系···························································································································42 26. 如何进行组分配/FRT 分配 ·······················································································································44 27. 如何查看帮助信息··································································································································45 28. 如何操作联动盘·····································································································································45 29. 如何打开/关闭打印机······························································································································46 30. 如何替换设备········································································································································48页码:1/60。

GB16808可燃气体泄露报警装置(2023新版)

GB16808可燃气体泄露报警装置(2023新版)

GB16808可燃气体泄露报警装置(2023新版)概述本文档介绍了GB可燃气体泄露报警装置(2023新版)的相关信息和要求。

标准要求根据GB标准 (2023新版),可燃气体泄露报警装置需要符合以下要求:1. 设备应当能够及时、准确地检测可燃气体泄露,并发出报警信号。

2. 设备的最大响应时间应符合规定的要求。

3. 设备应当具备可靠的自检功能,并能及时报告自检结果。

4. 设备的材料和结构应当能够在正常使用条件下确保安全性和可靠性。

5. 设备的安装、调试和维护应符合相应的规范和要求。

产品特性GB可燃气体泄露报警装置(2023新版)具有以下特性:1. 灵敏度高:能够精确检测可燃气体的泄露,并在短时间内发出报警信号。

2. 可靠性强:经过严格测试和认证,能够在各种环境条件下稳定工作。

3. 自检功能:具备自检功能,能够及时检测设备状态,确保设备正常运行。

4. 易安装和维护:符合标准的安装和维护要求,简化了安装和维护过程。

使用场景GB可燃气体泄露报警装置(2023新版)适用于以下场景:1. 工业厂房:用于气体泄露监测和安全报警,保护工人和设备安全。

2. 商业建筑:用于商场、办公楼等场所,确保人员安全。

3. 住宅区域:用于家庭天然气泄露监测,预防火灾事故发生。

总结GB可燃气体泄露报警装置(2023新版)是一种功能强大、可靠性高的设备,用于及时监测和报警可燃气体泄露。

它的广泛应用范围和先进的技术特性使其成为保障人员和财产安全的重要工具。

以上是关于GB16808可燃气体泄露报警装置(2023新版)的简要介绍和相关要求。

GB可燃气体报警控制器新版

GB可燃气体报警控制器新版

G B可燃气体报警控制器新版Document serial number【LGGKGB-LGG98YT-LGGT8CB-LGUT-GB16808可燃气体报警控制器1、范围本标准规定了可燃气体报警控制器的范围、分类、要求、试验、检验规则、标志和便用说明书。

本标准适用于一般工业与民用建筑中安装使用的可燃气体报警控制器(以下简称控制器),其它环境中安装的具有特殊性能的控制器,除特殊要求应由有关标准另行规定外,亦应执行本标准。

2、规范性引用文件下列文件对于本文件的应用是必不可少的。

凡是注日期的引用文件.仅所注日期的版本适用于本文件.凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。

家用和类似用途电器的安全第l部分:通用要求GB/T9969工业产品使用说明书总则GB 12978消防电子产品检验规则GB 15322可燃气体探测器GB 16838消防电子产品环境试验方法及严酷等级GB/T 电磁兼容试验和测量技术静电放电抗扰度试验GB/T 电磁兼容试验和测量技术射频电磁场辐射抗扰度试验G8/电磁兼容试验和测量技术电快速瞬变脉冲群抗扰度试验GB/电磁兼容试验和测量技术浪涌(冲击)抗扰度试验GB/电磁兼容试验和测量技术射频场感应的传导骚扰抗扰度试验GB/电磁兼容试验和测量技术电压暂降、短时中断和电压变化的抗扰度试验3分类控制器按工作方式分为:a)总线制;b)多线制。

控制器按便用环境分为:a)室内使用型;b)宝外使用型。

控制器按应用方式分为:a)独立型(不具有向其它控制器传递信息功能的控制器):b)区域型(具有向其它控制器传递信息功能的控制器):c)集中型(具有接收其它控制器传递的信息并集中显示功能的控制器).4术语和定义屏蔽状态disabled condition控侧器在屏蔽功能启动后所处的状态。

监管信号supervisory signal控制器监视的与其连接设备发出的除可燃气体报警、故障信号之外的其它输入信号.监管报警状态supervisory signal condition控制器发出监管报警信号时所处的状态。

GB16806《消防联动控制系统》

GB16806《消防联动控制系统》

GB16806《消防联动控制系统》目录第一章产品标准及市场准入制度 (4)国家认证认可监督管理委员会2007年第4号公告 (4) 国家认证认可监督管理委员会2007年第9号公告 (5) 公安部消防产品合格评定中心2007年第76文 (7) 第二章消防联动控制系统概述 (10)第一节消防联动控制器 (10)一、分类 (11)二、功能和性能 (11)三、组成与工作原理 (14)四、工程应用 (18)第二节气体灭火控制器 (18)一、主要功能 (19)二、组成与工作原理 (21)第三节消防电气控制装置 (22)一、消防电气控制装置的分类 (22)二、消防电气控制装置的功能 (24)三、组成与工作原理 (24)第四节消防设备应急电源 (25)一、分类与型号编制 (25)二、功能要求 (26)三、组成与工作原理 (29)四、主要部件 (31)五、主要技术参数与特性及主要特点 (32)第五节消防应急广播设备 (34)一、功能 (34)二、组成与工作原理 (35)第六节消防电话 (36)一、功能 (36)二、组成与工作原理 (40)第七节传输设备 (41)第八节消防控制室图形显示装置 (42)一、消防控制室图形显示装置的功能 (42)二、组成与工作原理 (45)第九节消防联动模块 (47)一、中继模块 (47)二、输入模块 (47)三、输出模块 (48)四、输入/输出模块 (49)第十节消防电动装置 (49)一、基本功能 (49)二、组成与工作原理 (49)第十一节消火栓按钮 (50)一、功能与性能 (50)消火栓按钮具有以下主要功能与性能: (50)二、组成与工作原理 (51)第三章 GB16806-2006《消防联动控制系统》标准条文解释.. 52第一节一般要求 (52)第二节消防联动控制器 (61)第三节气体灭火控制器 (75)第四节消防电气控制装置 (82)第五节消防设备应急电源 (88)【条文说明】本条规定了直流输出消防设备应急电源的直流电压稳定度和负载稳定度。

可燃气体报警控制器标准

可燃气体报警控制器标准

可燃气体报警控制器标准可燃气体报警控制器是一种用于监测和控制室内可燃气体浓度的设备,其作用在于及时发现可能存在的可燃气体泄漏情况,并及时采取措施进行处理,以确保人员和财产的安全。

随着现代化建筑和生产设施的不断增多,可燃气体报警控制器的需求也在逐渐增加。

然而,由于市场上存在各种各样的可燃气体报警控制器产品,标准的统一性和规范性对于确保设备的可靠性和准确性至关重要。

是指针对可燃气体报警控制器制定的一套规范和标准化要求,目的在于规范和统一设备的设计、制造、安装和使用,以确保设备在不同环境和应用场景下的性能表现。

通过遵循可燃气体报警控制器标准,可以有效提高设备的可靠性和稳定性,减少因设备失效而造成的事故风险,保障人员生命财产安全。

可燃气体报警控制器标准涉及到的内容广泛,主要包括设备的技术要求、性能指标、安装位置要求、测试方法、维护要求等,其中最重要的是设备的技术要求和性能指标。

设备的技术要求包括设备的结构设计、传感器选择、信号处理算法等方面的要求,而性能指标则是评价设备性能优劣的重要指标,包括灵敏度、响应时间、误报率等方面的指标。

在可燃气体报警控制器标准中,各项技术要求和性能指标都是相互关联的,彼此之间存在一定的平衡和权衡关系。

例如,为了提高设备的灵敏度,可以采用更加灵敏的传感器或改进信号处理算法,但同时也需要考虑到误报率的控制,避免设备对环境中的干扰因素过于敏感而导致误报。

因此,在制定可燃气体报警控制器标准时,需要综合考虑各项要求,确保设备在各种情况下都能够正常工作。

除了技术要求和性能指标外,可燃气体报警控制器标准还包括了安装位置要求、测试方法、维护要求等方面的规定。

其中,安装位置要求是指设备在安装时需要遵循的一些要求,包括安装高度、安装位置、安装数量等,这些要求直接关系到设备的监测效果和使用效果。

测试方法是指测试设备性能和功能的一些标准化方法,通过这些方法可以评估设备的性能是否符合标准要求。

维护要求是指设备在日常使用中需要进行的保养和维护工作,确保设备长期稳定可靠地运行。

根据石油化工企业设计防火标准2018年版下列关于火灾自动报警

根据石油化工企业设计防火标准2018年版下列关于火灾自动报警

根据石油化工企业设计防火标准2018年版下列关于火灾自动报警(一)火灾自动报警系统的配置要求
1. 一般设置有火灾自动报警控制器、火灾探测器、声光报警器、警铃和自动喷水系统控制器等主设备;
2. 根据火灾危险的程度可以设置不同的报警设备,例如,烟雾探测器、火焰探测器、火灾报警控制器等;
3. 火灾自动报警系统的配置应符合国家和地方的有关规定,应具备足够的安全性;
4. 报警信号的发出应符合国家有关规定,提高火灾报警系统的及时性;
5. 报警设备之间应有足够的备份机制,使得系统更加安全可靠;
6. 火灾自动报警系统应有自动测试功能,定期进行测试,确保火灾自动报警系统能够正常工作;
7. 火灾自动报警系统应有故障提示功能,及时发现设备故障,及时采取维修措施;
8. 火灾自动报警系统要安装在易受火灾损坏的重要部位,以及消防资源的重要接入点。

燃气报警器技术规定

燃气报警器技术规定

燃气报警器技术规定 Jenny was compiled in January 2021可燃气体探测器技术规定1 适用范围本规定适用于进行可燃气体探测器采购。

可燃气体探测器应满足或高于下面列出的规范和标准的最新版本的要求。

如果几种规范和标准的相关要求适用于同一情况,则应遵循相关要求最为严格的条款。

若本技术规定与相关的技术规定或标准有冲突,则应向业主咨询并得到其书面裁决后才能开展工作。

本技术规定指定产品应遵循的规范和标准主要包括但不仅仅限于以下所列范围:GB16808 可燃气体报警控制器技术要求和实验方法GB12358 作业场所环境气体检测报警仪通用技术要求测量范围为0~100%LEL的点型可燃气体探测器GB50058 爆炸和火灾危险环境电气装置设计规范GB4208 外壳防护等级(IP代码)GB50493 石油化工燃气体毒气体检测报警设计规范GB15332 可燃气体探测器爆炸性气体环境用电器设备第1部分:通用要求爆炸性气体环境用电器设备第2部分:隔爆型“d”GB12978 火灾报警设备检验规则JJG693 可燃气体检测报警器检定规程SH 3063 石油化工企业可燃气体和有毒气体探测报警设计规范其它未列出的与本产品有关的规范和标准,厂家有义务主动向业主提供。

2技术规定2 .1技术性能要求可燃气体探测系统应能快速和可靠地进行早期检测气体的泄漏,且系统性能的测试不应对系统的运行造成影响。

系统由探测器、报警器组成。

探测器的安装方式,安装地点,位号,数量等参见相应的数据表。

可燃气体探测器可根据情况选用红外吸收或催化燃烧探测原理。

测量范围应是可燃气体爆炸下限浓度的0~100%。

应具有较高的测量准确度,探测器的准确度应优于±3%LEL,。

应具有较高的灵敏度,对于可燃气体的微小变化,应有相应的信号输出。

探测器对可燃气体浓度变化的响应时间红外吸收型T90≤15s,催化燃烧型T90≤20s。

应能输出与气体浓度成比例的信号,信号类型应为4~20mADC模拟信号。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

GB16808可燃气体报警控制器1、围本标准规定了可燃气体报警控制器的围、分类、要求、试验、检验规则、标志和便用说明书。

本标准适用于一般工业与民用建筑中安装使用的可燃气体报警控制器(以下简称控制器),其它环境中安装的具有特殊性能的控制器,除特殊要求应由有关标准另行规定外,亦应执行本标准。

2、规性引用文件下列文件对于本文件的应用是必不可少的。

凡是注日期的引用文件.仅所注日期的版本适用于本文件.凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。

GB4706.1-2005家用和类似用途电器的安全第l部分:通用要求GB/T9969工业产品使用说明书总则GB 12978消防电子产品检验规则GB 15322可燃气体探测器GB 16838消防电子产品环境试验方法及严酷等级GB/T 17626.2电磁兼容试验和测量技术静电放电抗扰度试验GB/T 17626.3电磁兼容试验和测量技术射频电磁场辐射抗扰度试验G8/T17626.4电磁兼容试验和测量技术电快速瞬变脉冲群抗扰度试验GB/T17626.5电磁兼容试验和测量技术浪涌(冲击)抗扰度试验GB/T17626.6电磁兼容试验和测量技术射频场感应的传导骚扰抗扰度试验GB/T17626.11电磁兼容试验和测量技术电压暂降、短时中断和电压变化的抗扰度试验3分类3.1控制器按工作方式分为:a)总线制;b)多线制。

3.2控制器按便用环境分为:a)室使用型;b)宝外使用型。

3.3控制器按应用方式分为:a)独立型(不具有向其它控制器传递信息功能的控制器):b)区域型(具有向其它控制器传递信息功能的控制器):c)集中型(具有接收其它控制器传递的信息并集中显示功能的控制器).4术语和定义4.1屏蔽状态disabled condition控侧器在屏蔽功能启动后所处的状态。

4.2监管信号supervisory signal控制器监视的与其连接设备发出的除可燃气体报警、故障信号之外的其它输入信号.4.3监管报警状态supervisory signal condition控制器发出监管报警信号时所处的状态。

4.4自检状态test condition控制器进行自检功能时所处的状态。

4.5正常监视状态quiescent condition控制器接通电源后,无可燃气体报警、故障报警、屏蔽、监管报警、自检等发生时所处的状态。

5要求5.1总则控制器应满足本章的相关要求,并按第6章的规定进行试验.以确认对本章要求的符合性。

5.2外观要求5.2.1控制器应具备产品出厂时的完整包装,包装中应包含质量检验合格标志和使用说明书。

5.2.2控制器表面应无腐蚀、涂覆层脱落和起泡现象,无明显划伤、裂痕、毛刺等机械损伤,紧固部位无松动。

5.3主要部(器)件性能5.3.1通用要求5.3.1.1控制器的主要部(器)件,应采用符合相关标准的定型产品。

5.3.1.2控制器主电源应采用22Ov、50Hz交流电源,电源线输入端应设接线端子。

5.3.1.3控制器应设有保护接地端子5.3.1.4控制器应能为其连接的部件供电,可优先采用直流24V。

5.3.1.5控制器应具有中文功能标注和信息显示。

5.3.1.6控制器外壳应采用不燃材料或阻燃材料,室型控制器外壳防护等级应达到IP30的要求,室外型控制器外壳防护等级应达到IP55的要求。

5.3.1.7控制器由控制、显示和电源部分组成。

对于具有外接电源箱的控制器。

外接电源箱应仅能给前端可燃气体探测器供电。

外接电源箱的故障等状态不应影响控制器的正常工作。

5.3.1.8控制器应具有开/关机记录存储功能,并且该记录不应少于100条。

5.3.1.9控制器应具有中文说明书。

说明书的容应满足GB/T 9969的要求.5.3.2指示灯(器)控制器的可燃气体报警状态、监管报警状态、延时状态应采用红色指示灯(器)指示;故障、屏蔽状态应采用黄色指示灯(器)指示;电源工作状态应采用绿色指示灯(器)拍示。

5.3.2.2指示灯(器)功能应有中文标注5,3.2.3在不大于500lx环境光条件下,在正前方22.5视角围.状态指示灯(器)和电源指示灯(器)应在3m处清晰可见:其它指示灯(器)应在0.8m处清晰可见。

5.3.2.4采用闪亮方式的指示灯(器)每次点亮时间不应小于0.25s,其可燃气体报警指示灯(器)闪动顿率不应小于1Hz,故障指示灯(器)闪动顿率不应小于0.2 Hz。

5.3.2.5用一个指示灯(器)显示具体部位的故障、屏蔽和自检状态时,应能明确分辨.5.3.3字母(符)——数字显示器在5lx~500lx环境光线条件下,字母(符)——数字显示器,显示字符应在其正前方22.50视角、0.8m处可读。

5.3.4音响器件5.3.4.1在正常工作条件下,音响器件在其正前方1m处的声压级(A计权)应大于65dB,小于115 dB。

5.3.4.2在控制器额定工作电压85%条件下音响器件应能正常工作。

5.3.5熔断器用于电源线路的熔断器或其他过流保护器件,其额定电流值不应大于控制器最大工作电流的2倍。

当最大工作电流大于6A时,熔断器的额定电流值可采用最大工作电流的1.5倍.在靠近熔断器或其他过流保护器件处应清楚地标注其参数值。

5.3.6接线端子每一接线端子上都应清晰、牢固地标注其编号或符号,相应用途应在使用说明书中注明。

5.3.7充电器及备用电源5.3.7.1电源正极连接导线应为红色,负极应为黑色或蓝色。

5.3.7.2充电电流不应大于电池生产厂规定的额定值。

5.3.8开关和按键开关和按键应在其上或靠近的位置消楚地标注出其功能。

5.4整机功能5.4.1可燃气体报警功能5.4.1.1控制器应具有低限报警或低限、高限两段报警功能。

5.4.1.2控制器应能直接或间接地接收来自可燃气体探测器及其他报等触发器件的报警信号,发出可燃气体声、光报警信号,指示报警部位,记录报警时间,并予以保持,直至手动复位。

5.4.1.3当有可燃气体报警信号输入时.控制器应在10s发出报警声、光信号。

对来自可燃气体探测器的报警信号可设置报警延时,其最大延时时间不应超过1min,延时期间应有延时光指示,延时设置信息应能通过本机操作查询。

5.4.1.4控制器在可燃气体报警状态下应至少有两组控制输出接点。

5.4.1.5控制器应有专用可燃气体报警总指示灯(器)。

控制器处于可燃气体报警状态时,总指示灯(器)应点亮。

5.4.1.6可燃气体报警声信号应能手动消除,当再次有可燃气体报警信号输入时,应能再次启动。

5.4.1.7控制器应满足下述要求:a)应能显示当前可燃气体报警部位的总数。

b)应能区分最先报警部位。

c)后续报警部位应按报警时间顺序连续显示。

当显示区域不足以显示全部报警部位时,应按顺序循环显示;同时应设手动查询按钮(键)。

5.4.1.8控制器应设手动复位按钮(键),复位后,仍然存在的状态及相关信息均应保持或在20s 重新建立。

5.4.1.9控制器报警计时装置的日计时误差不应超过30s,使用打印机记录报警时间时,应打印出月、日、时、分等信息,但不能仅使用打印机记录报警时间。

5.4.1.10控制器应具有报警历史事件记录功能,记录相关信息不少于999条,且在控制器断电后能保持信息14d。

5.4.1.11通过控制器可改变与其连接的可燃气体探测器报警设定值时,对可燃气体探测器设定的报警设定值应能手动可查。

5.4.1.12除复位操作外,对控制器的任何操作均不应影响控制器接收和发出可燃气体报警信号.5.4,2可燃气体报警控制功能(仅适于具有此项功能的控制器)5.4.2.1控制器在可燃气体报警状态下应有火灾声和/或光警报器控制输出。

5.4.2.2控制器应设置手动/自动状态转换按钮(键),并应能指示手动/自动控制状态信息。

5.4.2.3控制器应设置其它控制输出,用于控制用户信息传输装置和消防联动设备等设备,并满足下述要求:a)每一控制输出应具有可编程功能,报警区域符合联动控制触发条件的一只可燃气体探测器或一只手动火灾报警按钮发出可燃气体报警信号时,控制器应发出启动输出信号;b)每一控制输出应有对应的手动直接控制按钮(键),控制器不应采用软件方式实现手动直接控制按钮(键)的控制功能。

5.4.2.4控制器在发出可燃气体报警信号后3s应启动相关的控制输出(有延时要求时除外)。

5.4.2.5控制器应能手动消除和启动火灾声和/或光警报器的声警报信号,消声后,有新的可燃气体报警信号时,声警报信号应能重新启动。

5.4.2.6具有传输可燃气体报警信息功能的控制器,在可燃气体报警信息传输期间应有光指示.并保持至复位,如有反馈信号输入,应有接收显示。

对于采用独立指示灯(器)作为传输可燃气体报警信息显示的控制器,如有反馈信号输入,可用该指示灯(器)转为接收显示,并保持至复位.5.4.2.7控制器发出消防联动设备控制信号时,应发出相应的声光信号指示,该光信号指示不能被覆盖且应保持至手动恢复;在接收到消防联动控制设备反馈信号10s应发出相应的声光信号,并保持至消防联动设备恢复。

5.4.2.8如需要设置控制输出延时,延时应按下述方式设置:a)对可燃气体声和/或光警报器及对消防联动设备控制输出的延时,应通过可燃气体探测器和/或手动火灾报等按钮和/或特定部位的信号实现;b)控制可燃气体报警信息传输的延时应通过可燃气体探测器和/或特定部位的信号实现;c)延时不应超过10min,设置延时时间变化步长不应超过1min;d)在延时期间,应能手动插入或通过手动火灾报警按钮而直接启动输出功能:e)任一输出延时均不应影响其它输出功能的正常工作,延时期间应有延时光指示。

5.4,2.9当控制器要求接收来自可燃气体探测器和/或手动火灾报警按钮的1个以上报警信号才能发出控制输出时,当收到第一个报警信号后,在收到要求的后续报警信号前,控制器应进入可燃气体报警状态;但可设有分别或全部禁止对火灾声和/或光警报器、火灾报警传输设备和消防联动设备输出操作的手段。

禁止对某一设备输出操作不应影响对其它设备的输出操作。

5.4.3故障报警功能5.4.3.1控制器应设专用故障总指示灯(器),无论控制器处于何种状态,只要有故障信号存在,该故障总指示灯(器)应点亮。

5.4.3.2有下列情形之一时,控制器应能在100s发出与可燃气体报警信号有明显区别的声、光故障信号:a) 控制器与可燃气体探测器及所连接的报警触发器件间连接线断路、短路和影响可燃气体报警功能的接地;b) 与控制器连接的可燃气体探测器的气敏元件脱落;c) 控制器与外接电源箱之间的连接线断路、短路;d) 控制器主电源欠压;e) 给控制器备用电源充电的充电器与备用电源之间连接线断路、短路;f) 控制器与其备用电源之间连接线断路。

相关文档