EMC VxRail超融合平台-运维管理手册
EMC VPLEX Metro架构日常维护手册
EMC VPLEX Metro 日常维护手册1.登录 VPLEXVPLEX管理服务器的默认用户如下:VPLEX初始化配置需要使用serivce用户登录,日常管理建议使用admin用户。
Admin用户第一次登录时需要修改密码,密码必须遵循如下密码策略:a) 至少14位,包含数字、大写、小写、特殊字符b) 不能是dictionary wordsc) 离上一次修改至少1天才能作更改d) 每隔90天必须修改一次,从第75天开始弹出密码修改提示VPLEX包括图形管理接口VPLEX Unishpere和命令行管理接口VPLEX CLI。
1.1 登录VPLEX Unisphere支持VPLEX Unisphere的浏览器包括:•英文版Windows:Internet Exporter 7 或以上、Firefox 3.5.5或以上•中文版Windows:英文版的firefox 3.5.x、Firefox 3.6.x•Adobe flash player v10.0.0或以上在浏览器输入VPLEX管理服务器的IP地址,如10.111.111.136:点击Continue to this website,出现登录画面。
输入用户名service和密码,点击Login,进入VPLEX图形管理界面主画面:1.2 登录VPLEX CLI打开远程终端模拟软件putty,选择ssh,输入VPLEX管理服务器的IP地址然后点击连接,按提示输入用户名和密码即可登录到管理服务器。
之后,输入命令:vplexcli按提示输入用户名和密码(同上)后,即可进入VPLEX CLI命令行接口。
2. VPLEX 存储空间调配前提准备:光纤SAN交换机已完成zone配置。
后端存储可以正确识别VPLEX的后端端口;主机光纤通道卡可连接到VPLEX前端端口。
在VPLEX中,要完成存储空间的调配供主机使用需要经过以下步骤:1. Mask LUNs to vplex2. Vplex discover LUNs3. claim storage volumes4. create extents from claimed storage volumes5. create devices from extents6. create virtual volumes on devices7. register initiators8. create storage view2.1 Mask LUNs to vplex参照后端存储操作手册,在后端存储分配适当空间给VPLEX,下图示例中VNX5600分配了一个的TEST_LUN给VPLEX。
运维信息管理平台操作手册
数据中心运维信息管理系统操作手册2019年8月目录1. 引言 (3)1.1. 编写目的 (3)1.2. 背景 (3)1.3. 定义 (3)2. 功能清单 (4)3. 设备资产 (6)3.1. 概述 (6)3.2. 设备资产 (6)3.3. 厂商 (9)3.4. 合同 (10)3.5. 机房 (11)3.6. 标签 (12)3.7. 软件/系统 (13)4. 服务器管理 (15)4.1. 概述 (15)4.2. 服务器 (15)4.3. 类别 (17)4.4. 项目 (18)4.5. 标签 (19)4.6. 集群 (20)4.7. 资源池 (21)5. 网段和域名管理 (22)5.1. 概述 (22)5.2. IP网段 (22)5.3. IP管理 (23)5.4. 域名 (24)6. 配置管理 (26)6.1. 概述 (26)6.2. 配置 (26)6.3. 配置历史 (27)7. 记录管理 (29)7.1. 概述 (29)7.2. 故障 (29)7.3. 发布 (30)7.4. 计划 (32)7.5. 设备资产记录 (33)8. 账户管理 (36)8.1. 概述 (36)8.2. 我创建的 (36)8.3. 分享给我的 (37)8.4. 所有账户 (38)9. 知识库 (41)9.1. 概述 (41)9.2. 文章 (41)9.3. 分类 (43)9.4. 标签 (44)1.引言1.1. 编写目的说明:编写这份用户手册的目的主要是方便管理员使用该系统。
1.2. 背景软件系统名称:数据中心运维信息管理系统1.3. 定义1.设备资产:为建设数据中心所购买的硬件设备,如交换机、防火墙、F5等设备;2.服务器:在虚拟化平台为各应用系统开通的服务器;3.项目:某一具体的业务系统;4.网段:数据中心所管理的网段;5.域名:为应用系统开通的域名;6.配置:记录某一设备的具体配置信息;7.知识库:在数据中心运维工作中积累的技术知识。
VxRail 超融合平台初始化及更新手册
VxRail 超融合平台初始化及更新手册目录Preliminary Activity Tasks (3)Read, understand, and perform these tasks (3)Service Provider, Project Information and Customer Contact form (4)VxRail Reset Procedure (4)Attention: (4)Warnings and Disclaimers (4)Intended Audience: (5)Materials Required: (5)Reset Procedure (5)Prerequisites (5)Preparing for Reset (5)Running Reset (8)Example using Reset on Windows (8)After Reset (8)Reset Command Options (9)Best Practices and Troubleshooting (10)Resetting Clusters with Multiple Appliances (10)If you want to restore a multi-appliance VxRail cluster: (10)If you want to separate the appliances into multiple VxRail clusters: (10)Reset Output: Example output of Successful reset: (10)Reset Failure (11)Known Issues (12)Appendix A:VxRail Appliances with a Custom Initial IP address (13)Preliminary Activity TasksThis section may contain tasks that you must perform before going to the customer site. Make sure these tasks are complete before performing the procedure.Read, understand, and perform these tasks1. [ ] Table 1 lists tasks, cautions, warnings, notes, knowledgebase (KB) solutions, and Top 10 ServiceTopics that you need to be aware of before performing this activity. Read, understand, and when necessary perform any tasks contained in this table and any tasks contained in any associatedknowledgebase solution.Table 1 List of cautions, warnings, notes, KB solutions, and Top 10 Service Topics for thisactivityService Provider, Project Information and Customer Contact formThis form is automatically populated based on the information that is provided in the VxRail® Procedure Generator questionnaire prior to generating the procedure. This information is collected and used for reference purposes when referring back to this procedure at a later date and time.Section 2:Section 3:VxRail Reset ProcedureThese instructions describe how to reset the VxRail Appliance using the Factory Reset Script which returns the appliance to a first run state but leaves the underlying software load unchanged. The reset script can be executed in the field by a VxRail Appliance reseller, distributor, or EMC CSE.Use this process to reset between demonstrations or moves between customer sites for evaluation.The reset script takes approximately 30 minutes to complete, however if there are environmental problems (network connectivity, i.e.) it can fail.The unit must be in an otherwise healthy state, connected to the network and functioning for the reset script to be used.Attention:The reset script tool will wipe all data and defined User VMs from the appliance. If the customer wants to keep their data or VMs, they must back them up prior to running the tool.Always use the latest VxRail Reset tool for the factory reset function based on your model of VxRail. Warnings and Disclaimers•Reset destroys all virtual machines and datastores in your VxRail Cluster. VMs on mounted datastores that you don’t want the reset to delete should be unregistered.prior to executing the reset.The process cannot be interrupted and there are no data recovery options available once the Reset starts.•The Reset script and documentation may only be utilized by properly trained personnel.•The Reset script and documentation are only available to properly trained engineering, support, and sales organizations.•The Reset script and documentation must not be provided to anyone who is identified as a direct end-user of a VxRail product.•The Reset script and documentation must be removed from the customer’s appliance and premises after Reset is performed by qualified personnel.Note: Reset script 4.0.100 is required for all VxRail appliances with Release 4.0.100 software. Intended Audience:This procedure is intended to be used by QEP Distribution Partners and VARs performing POC demos. This Procedure is not to be used on production systems!Materials Required:From the website, download the reset package:•File Name: v4.0.100_reset.zip•MD5Sum: 966d86f7ef0b9b02445bcb06eb263dcbWARNING: This procedure deletes all data on the system. It should never be used on a production system.Reset ProcedureReset restores an appliance to factory settings. It uses the original software images and the factory-created backup file to restore your appliance:/vmfs/volumes/<service_datastore>/images,/vmfs/volumes/<service_datastore>/reset/configBundle.tgzPrerequisites• A workstation/laptop with a web browser is required. It must be either plugged into the 10GbE switch or able to logically reach the VxRail management VLAN on the 10GbE switch.Note: This PC must be able to access both the pre-reset and post-reset VLANs and IP Addresses. •The VxRail appliance must have all software images and the configBundle.tgz file on the service datastore.•The document assumes you are familiar with the VxRail Setup Guide, the VxRail Product Guide, vSphere Web Client usage, and ESXi usage (DCUI/CLI).•All ESXi hosts must have the same version of both the ESXi and VxRail VIB on them. Preparing for ResetWARNING: To prevent a possible issue with the decompression of the software bundle, EMC recommends that the upgrade bundle is decompressed using a 3rd party decompression utilitysuch as WinZip. Windows Explorer decompression may have difficulty handling large files resulting in file corruption.1. [ ] Download reset bundle v4.0.100_reset.zip from the EMC Support Zone website to VxRailworkstation/laptop.Note: All files can be found in bundle with name v4.0.100_reset.zip from the VxRail Support page on https:///downloads. EMC Highly recommends that all files be verified using the md5 sum for each ova file to ensure integrity.2. [ ] On the VxRail workstation/laptop, uncompress it into a folder that you can browse, such asC:\reset or /tmp/reset. This archive contains:•Reset script: consisting of two python scripts: reset.pyc and gen_ovfenv.pyc •reset.pyc is in the package reset_4.0.100-4907696.zip.•You should uncompress it first in order to get the reset script.•The v4.0.100_reset.zip bundle contains three files:•reset_4.0.100-4907696.zip•Python-2.7.8.msi•VMware-viclient-all-6.0.0-3562874.exe•Python libraries: pyVim and pyVMomiPython 2.7 is required for Reset. Python 2.6 will fail. If necessary, python 2.7.8 is recommended and includes the install exe for installation on your VxRail Management workstation/laptop.The Reset script is backwards compatible with all versions of VxRail so users should update to the latest version of the reset script. If previous versions of Python are installed on the managementworkstation, those versions should be uninstalled first and Python v2.7 installed.3. [ ] For VxRail appliances connected to an External vCenter, manually remove thecluster/VDS/management accounts in the External vCenter.4. [ ] (Optional) In the vSphere Web Client, go to the Marvin-Virtual-SAN-Datastore. Click on Manageand then Files. Delete the ISO and UPGRADE directories. DO NOT delete any directories named witha UUID.5. [ ] For each VxRail host in the VxRail cluster, identify the IP address assigned to the factory-createdVMkernel management interface (vmk0) in one of the following ways:a. The IP address is displayed in the vSphere Web Client (use vcserver to locate the networkinformation for the VMkernel adapter on each ESXi host)orb. The IP address is displayed in DCUI (console user interface for ESXi)orc. ssh into each ESXi host (or connect a console or monitor via BMC) and run the esxcli networkip interface ipv4 get command on each host. The username is root. Use the password for the ESXi hosts that was set during VxRail Initial Configuration. (For an un-configured VxRail appliance, the password is Passw0rd!) The output will be similar to what is shown below:esxcli network ip interface ipv4 get | grep "vmk0"vmk0 MARVIN Management IPv4 10.10.10.5 255.255.255.0 10.10.10.25500:25:90:eb:bc:0a 1500 65535 true STATICOn an un-configured VxRail appliance, ESXi IP addresses are either assigned by DHCP (if it was available in your network) or configured as IPv4 link-local addresses (starting with 169.254.x.y). On a configured VxRail appliance, ESXi IP addresses are specified by the user who set up the appliance.6. [ ] Fill in the IPv4 address of each ESXi host in the cluster (use additional space if there is more thanone appliance in a cluster):Host IPv4 AddressESXi host on node 1ESXi host on node 2ESXi host on node 3ESXi host on node 47. [ ] From the VxRail workstation/laptop, verify that you can ping each IPv4 addressNote: If you cannot access a host, try power-cycling the node first.8. [ ] Use vSphere Client to login vCenter Server to check current Management VLAN as below:Figure 1 Example: the management VLAN ID in this appliance is 117Note: If you cannot access vCenter Server, you will have to ask the customer for the management VLAN ID.Running ResetReset is run from the VxRail workstation/laptop, using the options described in the Reset Command Options section. Before running Reset, be sure to read the section on Best Practices and Troubleshooting so that you can use the Reset script correctly.Note: Using the --vlan option for Reset is recommended even if current management VLAN is not set ( in this case, use 0 for VLAN ID). It will modify the management VLAN ID saved in configBundle first before actually using the configBundle. It simplifies initial setup because the management VLAN ID is configured on all 4 ESXi hosts. Likewise, the --initialIpAddress,--initialSubnet, and --initialGateway options also simplify initial setup.Another benefit comes when a VxRail appliance is reset and remains in the same environment (I.e. It is not relocated to another network). In this case, retaining the management VLAN ID and initial IP information during a reset permits the VxRail Manager workstation/laptop to remain set for the correct VLAN and IP. If these options are not used, the instructions in the VxRail SetupGuide can be followed at a later time.If the VLAN option is not used, no changes will be made to the Management VLAN settings. It will remain exactly as previously set.All appliances and nodes in a VxRail cluster should be reset if one appliance or node needs to be reset. Use the following procedure:•If you have more than one appliance in your VxRail cluster, reset each secondary appliance, one at a time. We recommend that the secondary appliances be reset in the order in which they were added to the cluster. Power off all nodes after each appliance is reset.•If you only have one appliance in the VxRail cluster, or when you have finished resetting and shutting down all secondary appliances, reset the primary appliance.Example using Reset on Windows1. [ ] To reset the appliance use the following command:Example:C:\Python27\python.exe c:\reset\reset.pyc -d --destroyAllVMs -f <IPv4_node1> -a <IPv4_node2> -a <IPv4_node3> -a <IPv4_node4> --vlan <vlan_id>[ --initialIpAddress=<init_IPaddr> --initialSubnet=<init_netmask>--initialGateway=<init_gateway> ]After ResetNote: The password is now Passw0rd! for all ESXi hosts, vCenter Server Appliance, and VxRail Manager.1. [ ] For VxRail appliances connected to an External vCenter, manually remove thecluster/VDS/management accounts in the External vCenter.2. [ ] Point a browser to the VxRail Manager user interface to begin VxRail initial configuration followingthe instructions in “VxRail Initial Configuration” in the VxRail Setup Guide. The location is one of the following:<init_IPaddr>specified in the ‘--initialIpAddress’ option supplied to Resetorhttps://192.168.10.200, the default value for ResetIf you cannot reach VxRail at one of these IP addresses after Reset, follow the instructions in AppendixA to configure another initial IP address.Reset Command OptionsBest Practices and TroubleshootingResetting Clusters with Multiple AppliancesIf you want to restore a multi-appliance VxRail cluster:After performing initial configuration on the primary appliance in the VxRail cluster, power on and configure each secondary appliance, one at a time. The primary appliance will discover each secondary appliance when it is powered on. Then you will add it to the cluster before continuing with the next secondary appliance. For more information, including configuring the Management VLAN, see the VxRail Setup Guide, “Adding Appli ances to a VxRail Cluster”.If you want to separate the appliances into multiple VxRail clusters:When you run Reset on each appliance, assign a unique <init_IPaddr> with the ‘--initialIpAddress’option. Then point your browser to each <init_IPaddr> and run VxRail initial configuration to create separate VxRail clusters.Reset Output: Example output of Successful reset:Reset succeeds with INFO and WARNING output similar to the following:c:\Python27\python.exe reset.py -d --destroyAllVMs -f 10.10.10.11 --initialIpAddress=10.10.10.250 --initialSubnet=255.255.254.0--initialGateway=10.10.10.253 -a 10.10.10.12 -a 10.10.10.13 -a 10.10.10.14 Post-configuration Password:INFO Primary node supplied: 10.10.10.11 INFO Secondary node supplied:10.10.10.12 INFO Secondary node supplied: 10.10.10.13 INFO Secondary nodesupplied: 10.10.10.14INFO MARVIN VIB 3.x discovered on hostsVxRail 3.x WARNING================================================WARNING THE FOLLOWING ARE THE CURRENTLY REGISTERED VIRTUAL MACHINES:WARNING ['VMware vCenter Server Appliance', 'VxRail Manager', 'VMware vRealize Log Insight'] WARNING CONTINUING WILL DESTROY ALL VIRTUAL MACHINES REGISTERED WITH THE APPLIANCE.CONFIRM (YES/NO): YESWARNING DESTROYING ALL VMs ON 10.10.10.11: ['VMware vCenter Server Appliance', 'VxRail Manager', 'VMware vRealize Log Insight']…INFO Host 10.10.10.11 has VMs [] remaining. INFO Removing hosts from VSAN cluster.INFO Putting hosts in maintenance mode. INFO Resetting and rebooting hosts.INFO Waiting for hosts to finish rebooting to confirm reset ...…INFO Trying to connect to 10.10.10.14 ...INFO Host 10.10.10.14 not yet available, still waiting ... INFO Trying to connect to 10.10.10.14 ...INFO Connection to host 10.10.10.14 successful.INFO Regenerating VSAN and VMs on primary node (10.10.10.11). Assuming default password. INFO Deploying VM: VMware vCenter Server Appliance fromimages/vcsa-restore-original/.INFO Deploying VM: VxRail Manager from images/evorail-restore-original/. INFO Upgrading hardware on VM: VMware vCenter Server ApplianceINFO Enabling Ivy Bridge EVC for VM: VMware vCenter Server Appliance INFO Upgrading hardware on VM: VxRail ManagerINFO Enabling Ivy Bridge EVC for VM: VxRail ManagerINFO Setting VM AutostartInfo for: VxRail manager on 10.10.10.11. INFOstartAction: powerOn; stopAction: guestShutdownINFO Powering on VM: VxRail ManagerINFO Deploying VM: VMware vRealize Log Insight fromimages/log-insight-original/. INFO Reconfiguring VM 'VMware vRealize Log Insight' OVF environment: success.INFO Upgrading hardware on VM: VMware vRealize Log InsightINFO Enabling Ivy Bridge EVC for VM: VMware vRealize Log Insight INFO Restarting 'loudmouth'.INFO Finalizing settings on Shamu.Reset FailureReset can fail for a variety of reasons. If it does not complete successfully on all nodes in an appliance, it can be rerun just on the node(s) that did not reset properly.Infrequently, Reset can report a failure but eventually succeed. This can happen if an ESXi host takes longer to reboot than the 720-second timeout in Reset. The ESXi node can still continue to boot and it may finally succeed. You can determine whether or not an ESXi host was successfully reset by attempting to login in via ssh or DCUI. The password should have been reset to Passw0rd!If you cannot login with this default password, the host was NOT reset properly. Run Reset again only on the host that did not boot successfully.Another reason that Reset could fail is if the IPv4 address for vmk0 does not match the information saved in configBundle.tgz. This would happen if ESXi was assigned a static IP address instead of link-local DHCP after configBundle.tgz was created, but before initial configuration. The failure message displayed would indicate failure to connect to all hosts.Usin g the ‘--onlyRegeneratePrimary’ option will quickly redeploy the service VMs.Note: Since you have already reset the appliance, the default password, Passw0rd!, must be used instead of your original password.C:\Python27\python.exe c:\reset\reset.pyc -f <IPv4_node1>--onlyRegeneratePrimary --initialIpAddress=<init_IPaddr>--initialSubnet=<init_netmask> --initialGateway=<init_gateway>The reasons that Reset can fail include the following:•Failing to connect to or locate a specified ESXi host•Using an invalid IPv4 address as Reset command options•Having a proxy server configured on the VxRail workstation/laptop•Failing to deploy the Log Insight VM or VxRail Manager•Still failing after several automatic retriesKnown IssuesIf you have a typo on the Reset command line, such as using a space instead of ‘=’ in the option/value pairs that require one (--initialIpAddress, --initialSubnet, --initialGateway), all 3 options will be ignored. (e.g--initialIpAddress=10.10.10.200 is correct; --initialIpAddress 10.10.10.200 is incorrect) If Reset otherwise succeeds, you can follow the instructions in Appendix A to set the initial IP address.Appendix A: VxRail Appliances with a Custom Initial IP address WARNING: The following steps are to configure a custom IP address for initial access to VxRail if you cannot use the <init_IPaddr> specified in the ‘--initialIpAddress’ option or the default IP address, 192.168.10.200.Note: You are setting the IP address for the VxRail Manager in Release 4.0.1. [ ] Connect the vSphere (C#) Client to the IP address of ESXi host 1 using the root user and thepassword that Reset configured during ESXi software installation, Passw0rd!2. [ ] Click the Virtual Machines tab and select “VxRail Manager”. The VM should already be poweredon. If not, click the green play button to power it on and wait for it to boot.3. [ ] Open the Console and login as root with the default password Passw0rd!4. [ ] Stop vmware-marvin:/usr/bin/systemctl stop vmware-marvin.service5. [ ] Using the vami_set_network command, change the default IP address to a custom IP address,netmask, and gateway using the following syntax (all arguments are required)./opt/vmware/share/vami/vami_set_network eth0 STATICV4 <init_IPaddr><init_netmask> <init_gateway>6. [ ] Start vmware-marvin and restart loudmouth on VxRail Manager:/usr/bin/systemctl start vmware-marvin.service/usr/bin/systemctl restart vmware-loudmouth.service7. [ ] Restart loudmouth on the primary ESXi host:/etc/init.d/loudmouth restart。
DellEMC VXrail超融合平台技术白皮书
产品介绍Dell EMC VxRail 应用装置不要只刷新您的服务器;采用第 14 代 P OWER E DGE 服务器上的 V X R AIL 实现基础架构转型 敏捷性是加速 IT 转型的关键要素。
超融合是实现敏捷性的关键所在。
行业分析公司 ESG 的最近调查显示,绝大多数 (87%) 已采用 HCI 的组织表示 HCI 使他们的组织更敏捷。
其结果是他们为更广泛的工作负载部署 HCI ,大部分在 HCI 上运行 20% 甚至更多的应用程序。
Dell EMC VxRail™ 可通过标准化和自动化加速和简化 IT 。
采用第 14 代PowerEdge 上的 VxRail ,您不但能够刷新服务器,而且还能实现基础架构转型。
VxRail 应用装置优势 Dell EMC VxRail 在完整生命周期管理方面(包括高级自动化)投入了巨大力量,您从第一天开始就可以轻松使用它,以便您进一步简化 IT 基础架构和运营。
新一代 PowerEdge 服务器上的 VxRail 应用装置是完善、优化和强大的平台,有助于简化整个生命周期 — 从部署,到管 理、到扩展、到维护。
据 Silverton Consulting 的一项研究,VxRail 已经过验证,通过您自己进行 HCI 系统维护可提高多达 30% 的 TCO 优势。
此外,借助集成的端到端支持,VxRail 还可将维护成本降低 43%。
简而言之,VxRail 能够让您事半功倍,使您的 IT 人员把精力放在更具战略性的项目上,而不仅仅是维持正常运转。
VxRail 是受VMware vSAN TM 支持的唯一一个完全集成、预配置且经过测试的 HCI 应用装置,是 VMware 基础架构转型的标准。
VxRail 提供了一种简单、经济高效的超融合解决方案,可解决您的众多难题,并支持几乎任何使用情形,包括第一层应用程序和混合工作负载。
通过 DellEMC 可以更快、更好且更简单地提供虚拟桌面、业务关键型应用程序和远程办公室基础架构。
VxRail超融合产品功能详解
VxRail超融合产品功能详解VxRail超融合产品功能详解超融合架构凭借效率、灵活性、规模、成本和数据保护,已经成为最近⼏年的热门词汇。
超融合是指在同⼀套单元设备中不仅仅具备计算、⽹络、存储和服务器虚拟化等资源和技术,同时拥有横向扩展能⼒,可以为⽤户提供⼀个统⼀的资源池部署应⽤程序。
VxRail系列设备就是⼀款基于VMware vSphere、vSAN 和EMC软件的超融合解决⽅案,旨在帮助⽤户实现⼀体化IT基础架构的转型。
它采⽤模块化的分布式存储设计,实现了计算和存储的融合,⽤户可以从⼩规模起步,按需扩展,同时提供多种计算、内存和存储选项以满⾜各种使⽤情形的配置。
本⽂将主要介绍VxRail的硬件、⽹络和功能软件。
VxRail是Dell EMC今年推出的超融合产品,定位的⽬标市场包括虚拟桌⾯架构VDI、远程办公室、私有云和中⼩企业。
⽤户通过VxRail和vBlock或者VxRack就可以搭建⼀套完整的企业级解决⽅案,适合所有类型的⼯作负载,通过VMware vCenter实现统⼀管理,同时还拥有企业级的复制和保护能⼒。
VxRail 以集群的形式存在,集群由多个节点组成,系统最多⽀持16个硬件盒⼦,64个节点,3000台以上的虚拟机。
单个节点拥有独⽴的CPU、内存、存储和⽹络资源,采⽤X86架构,⽀持横向扩展功能。
硬件配置部分VxRail提供混合模式和全闪存模式⼆种硬件配置,全闪存模式单节点最多⽀持28个CPU内核,512GB 内存和19TB存储容量,混合模式单节点最多⽀持20个CPU内核,512GB内存和10TB存储容量。
具体配置见下图:VxRail全闪存模式推出了5种型号,具体配置见下表:VxRail混合模式推出4种型号,具体配置见下表:VxRail硬件配置规则汇总:在3.5版本中,单个集群最低配置为4个节点。
在4.0版本中,单个集群最低配置为3个节点;单个逻辑集群最多⽀持64个节点,超过32个节点需要进⾏RPQ;集群中前4个节点必须使⽤相同硬件型号;单个集群中不⽀持混合模式和全闪存模式⼆种节点共存;单个集群中不⽀持10G模块和1G模块混合使⽤;VxRail硬件扩展规则汇总:节点可以⽆中断地添加到集群o节点可以增量地添加到VxRail集群;o每个Quanta节点扩展都需要⼀个磁盘包。
EMCVxRail超融合平台-安装配置手册
EMC VxRail 超融合平台安装配置手册目录目录1. 客户信息 (4)1.1. 客户联系信息 (4)1.2. 产品清单 (4)1.3. 售后支持 (4)2. 地址与用户名规划 (5)2.1. IP 地址信息 (5)2.2. 用户登录信息 (6)2.3. DNS 配置 (6)3. VxRail 设备安装 (7)3.1. VxRail 初始化准备 (7)3.1.1. 环境准备 (7)3.1.2. 网络连接 (7)3.1.3. 启动VxRail (7)3.2. VxRail 初始化安装 (8)3.2.1. 初始化配置 (8)3.2.2. 登录VxRail Manager (15)3.2.3. 登录VCenter (18)4. VxRail 管理 (19)4.1. 设备开机 (19)4.2. 设备关机 (19)1. 客户信息1.1. 客户联系信息客户名称:地址:邮编:第一联系人:职务:电话:Email 第二联系人:职务:电话:Email1.2. 产品清单产品名称设备型号设备序列号VxRail VxRail 120 QCFVR1640980011.3. 售后支持设备在使用中有任何问题,请联系EMC24 小时支持热线:固话拨打:800-819-0009手机拨打:400-670-0009请提供故障设备的序列号,并记录case 号码。
2. 地址与用户名规划2.1. IP 地址信息设备信息IP 地址子网掩码网关vLAN ID vCenter 192.168.17.19 255.255.255. 192.168.17 17 Platform ServicesController192.168.17.22 0 .1VxRail Manger 192.168.17.20vRealize Log Insight 192.168.17.21ESXi01-ESXi04 192.168.17.15-18vMotion(ESXi01-ESXi04) 192.168.13.11-14 255.255.255.N/A 13vSAN (ESXi01-ESXi04)192.168.14.11-14 255.255.255.N/A 14 BMC 地址Node 1 Node 2 192.168.17.11 255.255.255.192.168.17.12 255.255.255.192.168.17.1端口acccess 到vlan17Node 3 192.168.17.13 255.255.255.Node 4192.168.17.14 255.255.255.2.2. 用户登录信息设备信息用户名密码vCenter ***************************Platform ServicesControllerN/AVxRail Manger ***************************vRealize Log Insight adminESXi01-ESXi04 rootBMC admin2.3. DNS 配置请在DNS 服务器上增加如下域名解析:IP 地址域名192.168.17.15 192.168.17.16 192.168.17.17 192.168.17.18 192.168.17.19 192.168.17.20 192.168.17.21 192.168.17.22 3. VxRail 设备安装3.1. VxRail 初始化准备3.1.1. 环境准备1. 本次安装的为 1 台VXRAIL APPLIANCE 120 ,网卡为10GB SFP+ 网卡2. 一台带有电口网卡的PC Server ,用于初始化VxRail3.1.2. 网络连接(本次环境为10GB SFP+ 网络)3.1.3. 启动VxRail1. 按指定顺序启动VxRail 的每个Node ,间隔至少30s 以上顺序为:Node4 Node3 Node2 Node13.2. VxRail 初始化安装3.2.1. 初始化配置1. 使用IE 登录VxRail 默认IP:https://192.168.10.200 , 并点击“开始”(笔记本应提前配置IP,例如192.168.10.201/24)2. 使点击“接受”3. 选择“分步”4. 添写系统相关信息5. 设置Hostname 、网络、用户密码6. 设置vMotion 网络7. 设置vSAN 信息8. 设置虚拟机网络9. 设置Loginsight 信息10. 点击验证11. 点击“构建VxRail ”,进行VxRail 初始化。
emc运营维护方案
emc运营维护方案一、前言EMC(企业内容管理)是指企业对组织内的信息进行收集、管理、存储、传递和利用的过程。
EMC系统的运营维护工作对于保障企业信息安全、提高工作效率具有重要意义。
本文旨在对EMC系统的运营维护方案进行详细阐述,以期提高系统的稳定性和可靠性。
二、EMC系统运营维护目标1. 系统稳定性:保障EMC系统的稳定运行,防止系统崩溃或故障。
2. 数据安全:加强数据备份和存储管理,防止数据丢失或泄露。
3. 性能优化:对系统进行定期性能调优,提高系统的运行效率。
4. 用户培训:定期进行用户培训,提高用户对系统的使用和维护意识。
5. 安全防护:加强系统安全防护措施,防范恶意攻击和病毒侵害。
三、EMC系统运营维护方案1. 系统运行监控定期监控EMC系统的运行情况,包括系统资源占用情况、磁盘空间利用率、网络带宽利用情况等。
对于异常情况及时进行报警并进行处理。
2. 数据备份与灾备制定完善的数据备份计划,包括全量备份和增量备份,确保数据的完整性和安全性。
同时建立灾备机制,保障系统在灾难发生时的快速恢复能力。
3. 系统性能调优定期对系统进行性能调优,包括数据库索引优化、系统参数调整、网络带宽优化等,提高系统的响应速度和并发处理能力。
4. 安全防护措施加强系统的安全防护措施,包括防火墙、入侵检测等安全设备的部署和配置,及时更新安全补丁,加强用户权限管理和访问控制。
5. 用户培训和技术支持定期对用户进行系统使用和维护方面的培训,提高用户的操作技能和安全意识。
对于用户遇到的技术问题,及时提供技术支持和指导。
6. 系统更新和升级定期对EMC系统进行版本更新和升级,保持系统的功能性和安全性。
同时对系统的硬件设备和基础软件进行定期检修和维护。
7. 日常巡检和故障处理定期对系统进行日常巡检,发现问题及时进行故障处理。
建立完善的故障处理流程和记录机制,保证故障能够及时得到解决。
8. 统计和报表生成定期对系统的运行情况进行统计和分析,生成相关的报表,以便监管部门和管理人员进行系统运行情况的了解和分析。
超融合数据中心-管理操作手册
超融合数据中心管理操作手册目录Contents1.登录虚拟化平台 (3)1.1.使用vSphere Client登录 (3)1.1.1.多种视图查看虚拟化环境 (5)1.2.使用vSphere Web Client登录 (8)2.部署虚拟机 (9)2.1.新建虚拟机 (9)2.1.1.挂载系统镜像 (27)2.1.2.安装VMware Tools (32)2.2.从模板部署虚拟机 (37)3.管理虚拟机 (55)3.1.编辑虚拟机设置 (55)3.1.1.虚拟机连接USB设备 (57)3.2.使用虚拟机快照 (70)3.3.迁移虚拟机 (72)3.3.1.在线迁移虚拟机到其他主机 (73)3.3.2.在线迁移虚拟机到其他存储位置 (77)3.4.克隆虚拟机 (81)3.5.删除虚拟机 (82)4.管理虚拟机操作系统 (83)4.1.Windows Server (83)4.1.1.关闭系统防火墙 (83)4.1.2.禁用密码安全策略 (85)4.1.3.禁用IPv6 (86)1. 登录虚拟化平台可使用安装vSphere Client方式和vSphere Web Client(Web浏览器方式)登录虚拟化平台进行管理操作;其中vSphere Client可登录中央管理器vCenter Server或单台ESXi主机,vSphere Web Client只能登录vCenter Server。
1.1. 使用vSphere Client登录a)安装VMware vSphere 5.5后点击如下图标;b)输入vCenter Server地址和用户名密码后点击登录,或输入单台ESXi主机地址和用户名密码后连接;c)忽略安全警告,进入管理界面;1.1.1. 多种视图查看虚拟化环境vSphere Client提供多种视图查看虚拟化环境,包括主机和群集、虚拟机和模板、数据存储和数据存储集群、网络。
可点击地址栏进入主页界面进行切换;主机和群集视图下,左栏可显示ESXi主机、资源池和虚拟机,点击相应对象可在右栏多个标签下查看其详细信息;如点击CLUSTER(群集),摘要标签页下显示vSphere HA、vSphere DRS概要信息;点击地址栏切换到其他视图;虚拟机和模板视图;数据存储和数据存储集群视图;网络视图;1.2. 使用vSphere Web Client登录打开网页浏览器(要求较新的IE版本或Chrome、Firefox,并安装有Adobe Flash插件),输入vCenter Server地址https://192.169.110.50:9443/vsphere-client下载安装客户端基础插件后可在浏览器内打开虚拟机控制台登录完成后进入欢迎界面;点击左上角红色方框内图标,进入主页或vCenter Server界面进行查看;2. 部署虚拟机可通过新建虚拟机、从模板部署虚拟机等方式进行虚拟机的部署。
VxRail 超融合平台安装部署手册
VxRail 超融合平台安装部署手册目录Preliminary Activity Tasks (3)Read, understand, and perform these tasks (3)Service Provider, Project Information and Customer Contact form (4)VxRail Single Appliance Installation Procedure (4)Overview: (4)Pre-installation preparation (4)VxRail hardware installation overview (5)VxRail model and software release cluster requirements (5)Site requirements (5)Task 1:Unpacking the VxRail appliance (6)Task 2:Installing the appliance in a cabinet (7)Task 3:Connecting cables to the VxRail appliance (14)Task 4:Connecting to a single TOR switch (15)Task 5:Before powering on VxRail (16)Task 6:Powering on the appliance (17)Using the VxRail BMC interface (17)Before you begin (17)About the VxRail BMC interface (18)Task 7:Accessing BIOS from a local console (18)Task 8:Identifying the BMC LAN Port configuration in BIOS (19)Task 9:Identifying the BMC DHCP address (20)Task 10:Configuring the BMC LAN Static IP Address (21)Task 11:Accessing the BMC Web console (22)Task 12:Using the BMC Web console to launch the remote console (23)Task 13:Using the BMC Web console to control server power (26)Configuring VxRail for the First time (26)Task 14:Configuring VxRail for the first time (26)Task 15:Installing the bezel (38)How to Change the IB Status for VSPEX BLUE/VxRail (40)Task 16:Connect to the Salesforce site (40)Task 17:Under ‘Case details’ complete the fields (40)Preliminary Activity TasksThis section may contain tasks that you must perform before going to the customer site. Make sure these tasks are complete before performing the procedure.Read, understand, and perform these tasks1. [ ] Table 1 lists tasks, cautions, warnings, notes, knowledgebase (KB) solutions, and Top 10Service Topics that you need to be aware of before performing this activity. Read, understand, and when necessary perform any tasks contained in this table and any tasks contained in any associated knowledgebase solution.Table 1 List of cautions, warnings, notes, KB solutions, and Top 10 Service Topics forthis activityService Provider, Project Information and Customer Contact formThis form is automatically populated based on the information that is provided in the VxRail® Procedure Generator questionnaire prior to generating the procedure. This information is collected and used for reference purposes when referring back to this procedure at a later date and time.Section 2:Section 3:VxRail Single Appliance Installation ProcedureOverview:This procedure only covers the physical hardware installation of a single VxRail Appliance. Out of scope for this procedure is adding an additional appliance to an already configured cluster. Additionally, this procedure does not cover any of the network configuration tasks necessary to result in a successful VxRail implementation. It is the customer’s responsibility to make certain that the network requirements have been met for the VxRail Appliance prior to the provisioning of VxRail.Pre-installation preparationIMPORTANT: It is critical to an efficient, successful installation to completely capture and confirm all network elements, IP, ToR Switch details, VLAN information as described in the Pre-Installation Checklist. Perform the following:1. Download the most recent version of the Pre-Installation Checklist and thoroughly review it. Thechecklist is available via the SolVe Desktop for VxRail.2. Collaboratively work with designated customer contacts to confirm all the necessary pre-requisiteshave been met per the checklist prior to going on site to perform the physical installation.3. Collaboratively work with designated customer contacts to capture and record the configuration andnetwork elements described in the checklist prior to going on site to perform the physical installation.4. Ensure the IP pool size is sufficient for the number of appliances in the cluster. Refer to individualswitch vendor documentation as described in the Pre-Installation Checklist for the individualconfiguration and confirmation techniques for customer relevant network elements.5. Pay special attention to confirmation of customer network topology, differences in ToR switch modelsincluding firmware and licenses within the planned target cluster.Note: The As-Built Configuration deliverable is automatically generated by completing the checklist and can be printed for reference on site. Use it for reference during VxRail configuration.VxRail hardware installation overviewThe procedure details the key steps necessary to install VxRail hardware and prepare it for implementation.These steps include but are not limited to:•Unpacking the appliance•Mounting the VxRail Appliance into the customer provided rack•(If applicable) mounting the ToR Switches into the customer provided rack•Cabling ToR switches to VxRail appliance nodes•Connecting to the customer network•Powering on VxRail applianceIMPORTANT: Confirm network readiness before performing an installation. Failure to have a properly configured Top of Rack switch will result in VxRail provisioning failure.VxRail model and software release cluster requirementsWhile new appliances are automatically discovered on addition to a cluster, the appliances being added must match the model and release level of the cluster in place.IMPORTANT: Adding a VxRail appliance with a newer software release DOES NOT automatically update other appliances in a cluster.Site requirementsThere are no restrictions on the location of the server in the cabinet. Allow at least 36 inches of service clearance in front of and behind the cabinet. Power distribution must support the number of outlets required for the servers and the server power rating listed on the Device Rating label on the chassis. For additional information, refer to the preparation/planning guides for your specific site and cabinet.Ensure you have the following available before installing the VxRail appliance:•Two people to lift the VxRail appliance.•Philips screwdriver.•Laptop or PC with Internet access to register for EMC Online Support, and with local network access to configure the VxRail system (Refer to the Pre-installation Site Checklist)• A cable to connect the laptop or PC to the top-of-rack switch. This may require a media converter depending on the type of ToR switch and the type of connectors on the appliance (SFP+ or RJ45). •Two 110 VAC circuits (VxRail 60 only) or two 220 VAC circuits (all other Gen 2 VxRail Appliances).Task 1: Unpacking the VxRail applianceWhen unpacking the appliance, preserve all the packaging materials in case you need to ship the appliance in the future.CAUTION: The appliance is heavy and should be removedfrom the package by two people. To avoid personal injuryand/or damage to the appliance, do not attempt to lift theappliance without a mechanical lift and help from anotherperson.1. [ ] Inspect the package for damage. If the package (or any of the packaging material) is damaged,contact your shipper.2. [ ] Using a utility knife, carefully open the shipping box.3. [ ] Remove the contents of the package as illustrated in the following table.Table 1 Removing package contents4. [ ] Verify that your package includes the following items:•VxRail appliance•Rack mount kit•Power cords•Front bezel and bezel key•Four red CAT6 Ethernet cables5. [ ] Verify that the customer also has the following items:•Eight blue CAT6 Ethernet cables (for appliances with RJ45 NICs only)•Eight SFP TwinAx cables (for appliances with SFP/SFP+ NICs only)Task 2: Installing the appliance in a cabinetTo install the server in a cabinet, you must perform the tasks below in the order listed.a. Review the warnings and recommendations section.b. Verify the contents of the mounting kit.c. Adjust the rail assemblies for the cabinet channel holes.d. Remove the inner rails from the rail assemblies.e. Attach the inner rails to the server.f. Install the slide rails in the cabinet.g. Install the server on the slide rails in the cabinet.h. Connect cables to the server.i. Install the bezel on the server.IMPORTANT: The cabinet in which you will install the server must have a full earth ground to provide reliable grounding. Additionally, the cabinet should have its own switchable power distribution. We suggest that you use a cabinet that has dual power distribution units, one on each side.We recommend that you use cabinet anti-tip devices, especially if you are installing or removing a server in the upper half of the cabinet when the lower half is empty.1. [ ] Verify that the server mounting kit includes the parts listed in the following table.Table 2 Mounting kit parts2 universal rail assemblies (consists of slide rails forconnection to the cabinet and inner rails for connectionto server)Four Phillips pan-head 8-32 x 0.35 in screws2U bezel (application specific)You need a # 2 Phillips-head screwdriver to complete the installation of the rails and server.2. [ ] Adjust the rail assemblies for the cabinet channel holes.The rail assemblies ship with round alignment posts at the end of the rails for cabinet channels(NEMA rails) with round holes. If your cabinet has channels with square holes, switch the railalignment posts to square posts.a. Remove the screw that secures the alignment post assembly.b. Push the plastic tab on the alignment post assembly up or down, depending on the rail end, andhold the tab in.c. Rotate the alignment post assembly either clockwise to switch from round posts to square posts orcounter clockwise to switch from square posts to round posts until the assembly clicks into place.d. Secure the alignment post assembly in place with the screw that you removed.Note: The screw goes in the hole opposite the hole from which you removed it.Figure 1 Switching from round rail alignment posts to square alignment posts3. [ ] Remove the inner rails from the rail assemblies.a. Slide the inner rail out from the slide rail as far as possible.b. On the inner rail, slide the blue disconnect tab forward to release the inner rail from the slide rail.c. Slide the inner rail completely out of the slide rail.Figure 2 Removing the inner rail from the slide rail4. [ ] Attach the inner rails to the server.a. With the flat side of the inner rail facing the side of the server, align the large end of the railnotches of the inner rail with the connection studs on the server and push the inner rail onto the connection studs.b. Slide the inner rail forward along the server until the studs fit securely into the small end of the railnotches.An audible click indicates that the rail is secure.Figure 3 Attaching an inner rail to the server5. [ ] Install the slide rails in the cabinet.The universal rail assemblies for this server support cabinets in which the front and rear mounting channels are 24 inches to 34 inches apart. Each assembly contains a right and a left slide rail.a. Select the 2U (3.5 in) of cabinet space for the server.Figure 4 Location for the rails in the 2U space for the serverb. From the front of the cabinet, align rail alignment posts with the rear channel holes for the selectedcabinet space for the server, and insert the alignment posts securely into the holes.An audible click indicates that the connection is secure.Figure 5 Inserting rail alignment posts into rear channel holesc. Secure the rail to the rear channel with a small stabilizer screw.Figure 6 Installing stabilizer screws6. [ ] Install the server on the rails in the cabinetCAUTION: The enclosure is heavy and should be installed into or removed from a rack by two people. To avoid personal injury and/or damage to the equipment, do not attempt to lift and install the enclosure into a rack without a mechanical lift and/or help from another person.a. On each slide rail, bring the ball bearing retainer assembly fully to the front, so it rides onto thesecurity knob.b. From the front of the cabinet, align the inner rails attached to the server, with the white plasticguide block on the front inside of each slide rail.Figure 7 Aligning the inner rail with white plastic guide block Note: When installing the server in the cabinet, do not pick the server up by its power/control modules and do not push on its power/control modules. These modules are on either side of the front of the server.c. From the front of the cabinet, align the inner rails, attached to the server, with the white plasticguide block on the front inside of each slide rail.d. Slide the server into the cabinet so the inner rail extends over the plastic guide blocks and the firstpart of the ball bearing retainer assemblies.e. Once the inner rails properly engage with the ball bearing retainer assemblies, push the serverinto the cabinet until the slide rails engage and lock.An audible click indicates that the slide rails are engaged and locked.f. On the outside of each rail assembly, slide the blue disconnect tab forward to unlock the server,and push the server completely into the cabinet.Figure 8 Inserting the server in the cabinetg. To further secure the rail assembly and server in the cabinet, insert and tighten a small stabilizerscrew directly behind each bezel latchFigure 9 Installing the stabilizer screwsTask 3: Connecting cables to the VxRail applianceIMPORTANT: Refer to the VxRail Pre-installation Site Checklist as needed for the customer environment specifics. Do not power on the VxRail appliance until after you have confirmed the ToR switch configuration is complete.1. [ ] Plug the power cords into the power supplies and connect these cords to AC power sources.2. [ ] Attach the I/O cables as appropriate:•Connect the VxRail appliance to a single ToR switchTask 4: Connecting to a single TOR switchIf you are using a single top-of-rack (TOR) switch, make the network connections as shown.Each of the four nodes in a VxRail appliance has two network ports.Figure 10 Single ToR Switch with SFP+ network connectionsFigure 11 Single ToR Switch with RJ45 network connections1. [ ] Connect each port on a node to the configured ports on the TOR switch.Note: Work with the customer and refer to the VxRail Pre-installation Site Checklist as needed for the port assignments on the ToR Switch. Plugging into any available port does not guarantee network connectivity.Figure 1 SFP+ Twinax 10GbE Network portsFigure 2 RJ45 10GbE Network ports2. [ ] Connect the management PC to a port on the switch, or to a VLAN that can access theappliance.When connecting the management PC, the key take-away is that you must have network connectivity from the management PC to the VxRail Appliance default IP address of 192.168.10.200.CAUTION: Do not power on the VxRail appliance until after you have confirmed the TOR switch configuration is complete. Refer to the VxRail Networking Guide for switch protocol requirements. Refer to the ToR switch vendor documentation for configuration instructions.Task 5: Before powering on VxRailDo not power on your VxRail until you have completed the following tasks:•Properly install the appliance in a cabinet.•Connect the VxRail NIC ports to one or more TOR switches.•Verified with the customer that the TOR switch and supporting network are configured according to the VxRail Networking Guide, including:•Reserved, non-conflicting IP addresses•Configured IPv4 and IPv6 multicast•Disabled Link Aggregation on ToR switch (LACP/EtherChannel)•Configured network services such as DNS•Connect your management PC to the TOR switch.Task 6: Powering on the applianceTurn the appliance on by selecting the power button for each node as illustrated in the following table.After powering on a node wait at least 30 seconds before powering up the next node. This avoids conflicts between the nodes during power up and ensure that all nodes can be discovered.1. [ ] Power up one node at a time in the following sequence:a. Node 4b. Node 3c. Node 2d. Node 12. [ ] Verify the fans are operational and no amber fault lights appear. Refer to the following table forLED indicator light status.Using the VxRail BMC interfaceBefore you beginFollow these precautions before using the VxRail appliance BMC Web and remote console. CAUTION: Failure to follow these guidelines can cause VxRail to operate incorrectly, and can cause data loss.•Do not power cycle the appliance using the BMC interface. VxRail centrally manages all of the nodes in the appliance. You must follow the proper procedure to gracefully shut down and start up theVxRail appliance. A hard power cycle through the BMC interface, without interfacing with VxRail, may leave the appliance in an unknown state that could have negative consequences such as dataunavailability or data loss.•Only configure the BMC LAN settings. Do not modify any other BIOS or BMC settings in any way.•Do not upgrade the BIOS or BMC firmware. Configuration changes or version mismatches will cause VxRail to stop operating.•Use the BMC Web console and remote console solely for read-only monitoring.About the VxRail BMC interfaceVxRail offers a baseboard management controller (BMC) interface for monitoring the physical state of the appliance through an independent connection. The VxRail BMC port is an interface that provides access through a LAN or Internet connection.The BMC on the appliance node can support a dedicated port or a shared port. A dedicated BMC port is required because the 10Gb ports are reserved exclusively for VxRail.Figure 3 SFP+ NodeFigure 4 RJ45 NodeYou can access the BIOS/BMC through either a locally attached VGA monitor and keyboard or a remote session if the BMC port is assigned a known IP address. Use a locally attached VGA monitor and keyboard to discover the BMC port configuration if the IP address is not known.Task 7: Accessing BIOS from a local consoleBefore starting, be sure the VGA/keyboard is properly connected to the appliance node.1. [ ] During the power-on self-test (POST), press <F2> to enter BIOS Setup.Figure 5 Press F2 to enter BIOS2. [ ] When prompted for a password, enteremcbiosTask 8: Identifying the BMC LAN Port configuration in BIOSVerify the BMC interface is set to a dedicated port.1. [ ] On the BIOS main screen, navigate to Server Mgmt > BMC network Configuration.2. [ ] Look at the entry for “Current BMC LAN Port State”. The setting should be “Dedicated-NIC”.Figure 6 BMC LAN Port Configuration3. [ ] Select “BMC LAN Port Configuration” to modify this setting to “Dedicated-NIC”, if necessar y.4. [ ] Be sure the Ethernet cable is positioned in the dedicated port on the appliance node.Task 9: Identifying the BMC DHCP addressIf the VxRail BMC port has been assigned an address by the DHCP server, use this procedure to find the IP address using a locally attached VGA display and keyboard.1. [ ] On the BIOS main screen, navigate to Server Mgmt > BMC network Configuration.2. [ ] Look for the “Station IP a ddress” in the BMC LAN configuration section. The following exampleshows the assigned IP address for the dedicated BMC port is 192.168.101.49.Figure 7 BMC LAN Configuration using DHCPTask 10: Configuring the BMC LAN Static IP AddressIn the event that a DHCP server is not available on the network segment that the VxRail appliance is connected to, the following instructions describe how to configure a static BMC LAN IP Address.1. [ ] On the BIOS main screen, navigate to Server Mgmt > BMC network Configuration.2. [ ] Using the arrow keys on the keyboard, select “Configuration Address Source”.3. [ ] Press the <Enter> key to select.4. [ ] Using the arrow keys, ch ange the selection to “Static on next reset”.5. [ ] Press <Enter> to make the selection.6. [ ] Configure the IP Address, Subnet Mask and Default Gateway according to the customer’snetwork requirements.7. [ ] Press F10 to save changes and exit the BIOS.8. [ ] Repeat for each additional node in the appliance or cluster if more than one appliance is present.Figure 8 Setting Static IP address for BMC portTask 11: Accessing the BMC Web consoleOnce the BMC port settings are correctly configured in BIOS, a web session can be initiated to BMC with a browser.•The BMC web console uses secure HTTP (HTTPS) for connectivity. Be sure to use a browser that support a cipher strength of at least 128-bit encryption.•To use the remote console (KVM) window from the BMC web console, Java Runtime Environment (JRE) must be installed.1. [ ] Use your Web browser to navigate to the BMC port IP address.For example:http://192.168.103.52. [ ] Log into the BMC Web console by entering the following username and password:Username: adminPassword: adminFigure 9 BMC Web Console LoginNote: Be sure to comply with the “Required Browser Settings” before initiating a web session.Figure 10 BMC DashboardTask 12: Using the BMC Web console to launch the remote console1. [ ] Navigate to Remote Control > Console RedirectionFigure 11 Starting Remote Console from BMC Web Sessiona. When you click “Java Console ”, a window is displayed to download the Java Network Launch Protocol,(jviewer.jnlp) file. This in turn downloads the standalone Java application implementing the remote console.Figure 12 Launch Java ConsoleFigure 13 Launch Java ViewerNote: The remote console window is a Java Applet that establishes TCP connections to the Integrated BMC Web console. The protocol used to run these connections is a unique KVM protocol and not HTTP or HTTPS. This protocol uses ports 7578 for KVM, 5120 for CDROM media redirection, and 5123 for Floppy/USB media redirection. Your local network environment must permit these connections to be made. Your firewall and, if you have a private internal network, your NAT (network address translation) settings must be configured accordingly.Figure 14 Remote Console with Java ViewerTask 13: Using the BMC Web console to control server powerActivities in the BMC web console must be limited as to not impact the operations of the VxRail appliance. The BMC web console can be used to remotely control power to an appliance node if necessary.1. [ ] From the BMC dashboard, navigate to Remote Control > Server Power ControlFigure 15 Power Control in BMC DashboardConfiguring VxRail for the First timeTask 14: Configuring VxRail for the first timeConnect your management PC or laptop to a powered on VxRail appliance to begin initial configuration. IMPORTANT: The VxRail Pre-Installation Site Checklist includes the entries for all of the customer configuration details to be applied to the VxRail appliance. Be sure you have access to this spreadsheet before continuing to configure the VxRail appliance.1. [ ] Before you proceed with the initial configuration of the new VxRail appliance:a. Configure the PC you are using to connect to an address on the same subnet as the VxRailappliance (default is 192.168.10.x/24).b. Connect your PC to a port on the TOR switch integrated with the VxRail appliance.Note: This switch port must be configured accordingly to allow proper network connectivity.c. Confirm that you can ping the VxRail initial IP address (default is 192.168.10.200).d. Confirm that the gateway is reachable.e. Work with the customer to confirm that the DNS server(s) are reachable (unless you are in anisolated environment) and that all host names are resolvable ein both forward and reverse look-up.Note: Refer to the Pre-Installation Site Checklist for information on forward and reverse lookup.2. [ ] Refer to the Pre-Installation Site Checklist and connect to VxRail Manager as follows,:Note: When entering hostnames in the VxRail First Run Wizard, all hostnames for ESX, vCenter, PSC, etc should be entered as simple hostnames. Do not enter FQDN hostnames as this will cause a mis-configuration.a. Launch a browser on your PC.b. Browse to the VxRail Manager IP address: https://192.168.10.200.The VxRail Welcome screen is displayed.Figure 16 VxRail Welcome ScreenYou are now connected to VxRail Manager and can provision the VxRail appliance.3. [ ] Before you provision the VxRail appliance for the first time, note the following:IMPORTANT: If the appliance is a DEMO or POC, refer to the DEMO KIT for instructions.Note: Successful provisioning completes in about 25 minutes during the "Build Appliance" phase.4. [ ] On the VxRail Manager Welcome screen, click GET STARTED.Figure 17 Initializing VxRail Configuration5. [ ] Select ACCEPT to accept the End User License Agreement (EULA).Figure 18 VxRail EULA 6. [ ] The Expected nodes page displays.Figure 19 Expected nodes7. [ ] Wait for all the nodes to load. Click the ‘I confirm I want to configure the listed hosts’checkbox and locate the Next button on the right side of the the screen.Figure 20 Expected nodes8. [ ] Click the Next button.9. [ ] Select how you would like to configure VxRail.Figure 21 VxRail Data Entry OptionsClick Step-by-step to continue. The Step-by-step option enables a wizard to enter the required VxRail information interactively.If you select Configuration file you will be prompted to select the *json file created within the Pre-installation Site Checklist. This file will populated the required VxRail information and you can skip to step 15 to continue.10. [ ] Enter the information on the System tab. Use the information collected on the Pre-InstallationSite Checklist .Note: If you are using the JSON file for pre-defined configuration, then use the steps below to review the input parameters as opposed to manually entering them.。
EMC VxRail超融合数据中心-方案建议书
EMC 融合平台EMC VxRail超融合数据中心方案建议书EMC VXRAIL 超融合平台:超级融合基础架构的跨越腾飞日期客户联系人全名客户公司名称客户公司地址尊敬的客户联系人称呼:您好!事物需要变革,而直面变革的时机已到。
IT 基础架构的作用不再仅仅是为业务提供支持,而是主动地推动业务发展。
压力在肩,您的基础架构必须利用有限的预算和资源来满足新应用程序与服务等不断浮现的业务需求。
当前,各类需求不断演化发展,要对硬件、软件和网络解决方案进行持续评估和集成,时间十分有限。
您需要打造一种能适应您业务需求的自动化动态基础架构。
如果您的 IT 基础架构妨碍到您调动资源、适应各种新的业务开展方式,那么,贵组织将面临在竞争中落后甚至被淘汰的风险。
为了满足层出不穷的业务需求,您曾经尝试过推进您的 IT 基础架构现代化进程,然而,不断的维护需求、长时间的集成以及漫长的技术评估周期统统成了阻挡您前进的拦路虎。
倘若无法让基础架构生命周期得到简化和重复利用,贵组织必然难以开展创新工作,及时响应市场需求。
您很清楚,您需要打破被动响应的恶性循环,找到能推动贵组织业务水平更上一层楼的 IT 基础架构解决方案。
您是锐意进取的革新者,您知道软件定义的数据中心 (SDDC) 这种作为服务交付的全自动敏捷型虚拟基础架构就是您未来要实现的目标。
但问题在于,如何才能通过经济高效的简单方式达成这一目标。
VCE VxRail™应用装置由 EMC 和 VMware 联合开发,是市面上唯一一款采用 VMware 超级融合软件进行了全面集成、预配置以及测试的超级融合基础架构应用装置,是部署完全虚拟化 SDDC 环境最简单、快捷的方式。
该应用装置将始终为您提供最新的 VMware 技术,通过简单、经济高效的超级融合解决方案为您实现数据中心转型,适用于多种任务关键型工作负载。
在其帮助下,您可以胸有成竹地实现可预测的发展,持续实现基础架构现代化目标。
VxRail超融合方案白皮书
适用于 VCE 融合基础架构解决方案的 EMC 数据保护选项
当您需要任意时间点恢复时
使用面向灾难和操作恢复(拥有虚拟机级精确性)的自动化资源调配和流程编排功能保护虚拟机。虚拟 化管理员可便利采用针对任意时间点恢复的连续复制,轻松地保护和复制虚拟机,实现相互依赖的应用 程序一致性。该解决方案为 100% 软件化且基于虚拟机管理程序的解决方案 — 包括集成到 VMware vCenter 中的自动化灾难恢复。同时,它使用同步或异步复制,提供跨任何距离的本地和远程复制。
EMC 针对 VxRail 的数据保护还提供管理和监视功能,可显著减少在审核、法规遵从性和满足其他报告 需求方面所花费的时间。您将能够进行更充分准备,更快地做出明智的决策,同时降低成本并提升效率
当您需要最可靠的保护存储解决方案时
享受世界上最可靠的保护存储和敏捷、灵活、高效的软件定义解决方案带来的种种优势。保护存储易于 部署,仅在几分钟内便可启动并正常运行。每个实例最多可扩展至 96 TB,使得您能够以低至 1 TB 的 增量随增长而付费,并根据需要在环境内的多个实例中分配此容量。它可以在标准硬件上运行,因此您 可以利用现有基础架构部署保护存储。
全面集成的数据保护
您的软件解决方案是否简化并扩展了您 VMware 环境的数据保护?
它应该做到这一点。
优化针对 VxRail 应用装置的数据保护,为关键业务数据提供全面集成的保护。
EMC VxRail超融合平台-运维管理手册
EMC VxRail超融合平台运维管理手册目录1. 产品信息 (3)1.1.产品清单 (3)1.2.售后支持 (3)1.2.1.登录VxRail Manager (3)1.2.2.查看系统状态 (4)1.2.3.登录VCenter (10)2. VxRail管理信息 (11)2.1.IP地址信息 (11)2.2.用户登录信息 (12)2.3.设备开机 (13)2.4.设备关机 (13)1.产品信息1.1.产品清单1.2.售后支持设备在使用中有任何问题,请联系EMC24小时支持热线:固话拨打:800-819-0009手机拨打:400-670-0009请提供故障设备的序列号,并记录case号码。
1.2.1.登录VxRail Manager1.单击“管理VxRail”,登录至管理介面输入用户名及之前设置的密码:***************************1.2.2.查看系统状态进入Dashbord主界面进入Support支持页面查看系统告警事件进入系统健康状态查看页面查看节点逻辑状态查看节点硬件状态进入系统配置界面1.2.3.登录VCenter登录vCenter地址192.168.105.19, 输入用户名及之前设置的密码:***************************2.VxRail管理信息2.1.IP地址信息2.2.用户登录信息2.3.设备开机按指定顺序启动VxRail的每个Node,间隔至少30s以上顺序为:Node4→Node3→Node2→Node12.4.设备关机登录VxRail Manager点击如下按钮,关闭整个集群。
VxRail Manager->配置->关闭。
emcvnx配置手册
第1章文档目录第1章VNX5400 硬件部分 ................................................................... 错误!未定义书签。
1.1.硬件部分: (4)1.2.设备基本信息 (4)1.2.1.开机注意事项 (4)1.2.2.开机环节 (5)1.2.3.关机前注意事项 (5)1.3.使用UNISPHERE进行配置 (6)1.3.1.登陆到管理界面 (6)1.3.2.创立Raid Group (12)1.3.3.创立LUN ............................................................................... 错误!未定义书签。
1.3.4.创立Storage Group ............................................................... 错误!未定义书签。
1.3.5.注册主机 ................................................................................ 错误!未定义书签。
1.3.6指派LUN ............................................................................... 错误!未定义书签。
1.3.7指派主机 ................................................................................ 错误!未定义书签。
1.3.7创立Mirror ............................................................................. 错误!未定义书签。
EMC VMAX存储日常运维操作手册
EMC VMAX 存储日常运维操作手册目录1登录Unisphere2VMAX存储划分空间操作2.1创建Thin devices2.2创建Meta Volume2.3创建Storage Group2.4创建主机组(Initiator Group)2.5创建端口组(Port Group)2.6创建Masking View2.7创建FAST策略2.8删除卷2.9如何查看LUN ID1 登录Unisphere在一台能够连接到管理网络的Windows主机上,使用IE浏览器7.0以上版本(需要安装Flash Player 11.2或更高版本),输入Unishpere Server的IP:https://127.0.0.1:8443输入用户名和密码登录:smc/smc登录后看到界面中有VMAX存储,点击该存储。
进入存储操作<System>主界面。
可以在这里查看存储当前的健康状况,也可以选择其他标签以完成其他功能操作。
2 VMAX存储划分空间操作前提准备:•空间需求规划与确认(Vol大小、数量等),是否需要有2台或多台主机共同访问•规划好主机访问VMAX的前端口数量,一般4个,最少要2个,且每个Director的前端口有 1~2个;EFGH假如需要2个前端口选择:1E0,2E0假如需要4个前端口选择:1E0,2E0,1F0,2F0•先配置好SAN交换机的zoning,一般一个zone里只有一块HBA卡•流程与相应的表格记录与更新(《SAN交换机连接配置表》, 《VMAX存储配置表》)在VMAX中,对主机进行卷映射需要经过以下步骤:1.创建Volumea)Thin device(小于240G),使用向导“Create Volumes”b)或Meta device(大于240G),使用向导“Create a Meta Volume”i.使用现有的Thin deviceii.新创建Thin device2.把Thin device 绑进pool里,也可以在前一步在创建TDEV的时候绑定pool3.创建Storage Group,4.并添加Thin device5.创建主机组(Initiator Group),根据VMAX所看到的连进来的主机HBA卡的WWN6.创建Port Group,根据前期规划给主机使用的VMAX的前端口集合,并做好交换机zonning7.创建Mask View,把Storage Group,Initiator Group,Port Group添加进MASK View接下来主机端操作:8.安装多路径软件Powerpath(Vmware环境不需要);检查OS的版本补丁,HBA卡驱动,必要的HBA卡优化参数;确定Powerpath的版本9.OS扫描外部磁盘(使用OS命令或重启主机);10.OS配置磁盘,创建文件系统(磁盘初始化和联机、创建PV、VG、LV等等)VMAX的操作步骤均可以通过Unisphere图形界面或者Solution Enabler的命令行操作。
DellEMC VXrail超融合平台技术白皮书
产品介绍Dell EMC VxRail 应用装置不要只刷新您的服务器;采用第 14 代 P OWER E DGE 服务器上的 V X R AIL 实现基础架构转型 敏捷性是加速 IT 转型的关键要素。
超融合是实现敏捷性的关键所在。
行业分析公司 ESG 的最近调查显示,绝大多数 (87%) 已采用 HCI 的组织表示 HCI 使他们的组织更敏捷。
其结果是他们为更广泛的工作负载部署 HCI ,大部分在 HCI 上运行 20% 甚至更多的应用程序。
Dell EMC VxRail™ 可通过标准化和自动化加速和简化 IT 。
采用第 14 代PowerEdge 上的 VxRail ,您不但能够刷新服务器,而且还能实现基础架构转型。
VxRail 应用装置优势 Dell EMC VxRail 在完整生命周期管理方面(包括高级自动化)投入了巨大力量,您从第一天开始就可以轻松使用它,以便您进一步简化 IT 基础架构和运营。
新一代 PowerEdge 服务器上的 VxRail 应用装置是完善、优化和强大的平台,有助于简化整个生命周期 — 从部署,到管 理、到扩展、到维护。
据 Silverton Consulting 的一项研究,VxRail 已经过验证,通过您自己进行 HCI 系统维护可提高多达 30% 的 TCO 优势。
此外,借助集成的端到端支持,VxRail 还可将维护成本降低 43%。
简而言之,VxRail 能够让您事半功倍,使您的 IT 人员把精力放在更具战略性的项目上,而不仅仅是维持正常运转。
VxRail 是受VMware vSAN TM 支持的唯一一个完全集成、预配置且经过测试的 HCI 应用装置,是 VMware 基础架构转型的标准。
VxRail 提供了一种简单、经济高效的超融合解决方案,可解决您的众多难题,并支持几乎任何使用情形,包括第一层应用程序和混合工作负载。
通过 DellEMC 可以更快、更好且更简单地提供虚拟桌面、业务关键型应用程序和远程办公室基础架构。
德尔·埃迈西亚 VxRail VXRAIL HCI 网络转型简化 VMWARE 云说明书
DATA SHEETDell EMC VxRailV X R AIL TRANSFORMS HCI N ETWORKING AND E NHANCES S IMPLICITY FOR THE VM WARE C LOUD•Proven to dramatically reduce OPEX, delivering up to 52% lower cost ofoperations over build your own HCIwhile integrated end-to-end supportreduces unplanned downtime by 90% •Based on 14th generation PowerEdge,a server platform that is uniquelydesigned and optimized for HCI, VxRaildelivers the utmost flexibility andmillions of configuration optionsenabling 2x more IOPS and half theresponse time – sustained at sub-1ms •Supports any HCI use case, including SAP HANA, file, graphics-intensiveVDI, big data and analytics, remoteoffice, and high performancecomputing•Industry-leading enterprise dataservices, including HCI-native data-at-rest encryption replication, backup, andfile services make VxRail ready foralmost any application or workload. All-flash models can leveragecompression, deduplication, anderasure coding for further efficiency •For edge implementations two-node direct connect makes VxRail moreaccessible. Multi-node scaling, storagecapacity expansion, mixed generationPowerEdge clusters, and flexible vSANlicensing enable adaptable growth thatmeets business demands •Automated deployment and lifecycle management of HCI infrastructureincluding networking through VxRailManager•Single point of global 24x7 support for both the hardware and software Agility is a key element to accelerating IT transformation. Hyper-converged is a key contributor to enabling agility. A recent survey by industry analyst firm ESG illustrates that the vast majority of organizations that have adopted, 87%, say that HCI has made their organization more agile. The result is they are deploying HCI for a wider variety of workloads, with most running 20% or more of their apps on HCI.Dell EMC VxRail™ accelerates and simplifies IT through standardization and automation. With VxRail, you don’t just deploy a server, you transform your infrastructure.The VxRail Appliance AdvantageDell EMC VxRail invests in the complete lifecycle, including advanced automation, making it easier for you from day one forward, allowing you to further simplify IT infrastructure and operations. VxRail Appliances on next gen PowerEdge servers are refined, optimized, and robust platforms that help you simplify your entire IT lifecycle – from deployment, to management, to scaling, to maintaining.VxRail is the only fully integrated, preconfigured, and tested HCI appliance powered by VMware vSAN TM and is the standard for transforming VMware infrastructures. VxRail provides a simple, cost effective hyper-converged solution that solves a wide range of your challenges and supports almost any use case, including tier-one applications and mixed workloads. Dell EMC enables faster, better, and simpler delivery of virtual desktops, business-critical applications, and remote office infrastructure.VxRail on 14th Generation PowerEdge ServersVxRail on 14thgeneration PowerEdge offers next-generation technologies that accelerate IT transformation and future proof your infrastructure.Dell EMC VxRail Data Sheet© 2018 Dell Inc. or its subsidiaries.Learn more about Dell EMC VxRail Contact a Dell EMC Expert View more resources Join the conversationwith #VxRail。
VxRail 超融合平台初始化及更新手册
VxRail 超融合平台初始化及更新手册目录Preliminary Activity Tasks (3)Read, understand, and perform these tasks (3)Service Provider, Project Information and Customer Contact form (4)VxRail Reset Procedure (4)Attention: (4)Warnings and Disclaimers (4)Intended Audience: (5)Materials Required: (5)Reset Procedure (5)Prerequisites (5)Preparing for Reset (5)Running Reset (8)Example using Reset on Windows (8)After Reset (8)Reset Command Options (9)Best Practices and Troubleshooting (10)Resetting Clusters with Multiple Appliances (10)If you want to restore a multi-appliance VxRail cluster: (10)If you want to separate the appliances into multiple VxRail clusters: (10)Reset Output: Example output of Successful reset: (10)Reset Failure (11)Known Issues (12)Appendix A:VxRail Appliances with a Custom Initial IP address (13)Preliminary Activity TasksThis section may contain tasks that you must perform before going to the customer site. Make sure these tasks are complete before performing the procedure.Read, understand, and perform these tasks1. [ ] Table 1 lists tasks, cautions, warnings, notes, knowledgebase (KB) solutions, and Top 10 ServiceTopics that you need to be aware of before performing this activity. Read, understand, and when necessary perform any tasks contained in this table and any tasks contained in any associatedknowledgebase solution.Table 1 List of cautions, warnings, notes, KB solutions, and Top 10 Service Topics for thisactivityService Provider, Project Information and Customer Contact formThis form is automatically populated based on the information that is provided in the VxRail® Procedure Generator questionnaire prior to generating the procedure. This information is collected and used for reference purposes when referring back to this procedure at a later date and time.Section 2:Section 3:VxRail Reset ProcedureThese instructions describe how to reset the VxRail Appliance using the Factory Reset Script which returns the appliance to a first run state but leaves the underlying software load unchanged. The reset script can be executed in the field by a VxRail Appliance reseller, distributor, or EMC CSE.Use this process to reset between demonstrations or moves between customer sites for evaluation.The reset script takes approximately 30 minutes to complete, however if there are environmental problems (network connectivity, i.e.) it can fail.The unit must be in an otherwise healthy state, connected to the network and functioning for the reset script to be used.Attention:The reset script tool will wipe all data and defined User VMs from the appliance. If the customer wants to keep their data or VMs, they must back them up prior to running the tool.Always use the latest VxRail Reset tool for the factory reset function based on your model of VxRail. Warnings and Disclaimers•Reset destroys all virtual machines and datastores in your VxRail Cluster. VMs on mounted datastores that you don’t want the reset to delete should be unregistered.prior to executing the reset.The process cannot be interrupted and there are no data recovery options available once the Reset starts.•The Reset script and documentation may only be utilized by properly trained personnel.•The Reset script and documentation are only available to properly trained engineering, support, and sales organizations.•The Reset script and documentation must not be provided to anyone who is identified as a direct end-user of a VxRail product.•The Reset script and documentation must be removed from the customer’s appliance and premises after Reset is performed by qualified personnel.Note: Reset script 4.0.100 is required for all VxRail appliances with Release 4.0.100 software. Intended Audience:This procedure is intended to be used by QEP Distribution Partners and VARs performing POC demos. This Procedure is not to be used on production systems!Materials Required:From the website, download the reset package:•File Name: v4.0.100_reset.zip•MD5Sum: 966d86f7ef0b9b02445bcb06eb263dcbWARNING: This procedure deletes all data on the system. It should never be used on a production system.Reset ProcedureReset restores an appliance to factory settings. It uses the original software images and the factory-created backup file to restore your appliance:/vmfs/volumes/<service_datastore>/images,/vmfs/volumes/<service_datastore>/reset/configBundle.tgzPrerequisites• A workstation/laptop with a web browser is required. It must be either plugged into the 10GbE switch or able to logically reach the VxRail management VLAN on the 10GbE switch.Note: This PC must be able to access both the pre-reset and post-reset VLANs and IP Addresses. •The VxRail appliance must have all software images and the configBundle.tgz file on the service datastore.•The document assumes you are familiar with the VxRail Setup Guide, the VxRail Product Guide, vSphere Web Client usage, and ESXi usage (DCUI/CLI).•All ESXi hosts must have the same version of both the ESXi and VxRail VIB on them. Preparing for ResetWARNING: To prevent a possible issue with the decompression of the software bundle, EMC recommends that the upgrade bundle is decompressed using a 3rd party decompression utilitysuch as WinZip. Windows Explorer decompression may have difficulty handling large files resulting in file corruption.1. [ ] Download reset bundle v4.0.100_reset.zip from the EMC Support Zone website to VxRailworkstation/laptop.Note: All files can be found in bundle with name v4.0.100_reset.zip from the VxRail Support page on https:///downloads. EMC Highly recommends that all files be verified using the md5 sum for each ova file to ensure integrity.2. [ ] On the VxRail workstation/laptop, uncompress it into a folder that you can browse, such asC:\reset or /tmp/reset. This archive contains:•Reset script: consisting of two python scripts: reset.pyc and gen_ovfenv.pyc •reset.pyc is in the package reset_4.0.100-4907696.zip.•You should uncompress it first in order to get the reset script.•The v4.0.100_reset.zip bundle contains three files:•reset_4.0.100-4907696.zip•Python-2.7.8.msi•VMware-viclient-all-6.0.0-3562874.exe•Python libraries: pyVim and pyVMomiPython 2.7 is required for Reset. Python 2.6 will fail. If necessary, python 2.7.8 is recommended and includes the install exe for installation on your VxRail Management workstation/laptop.The Reset script is backwards compatible with all versions of VxRail so users should update to the latest version of the reset script. If previous versions of Python are installed on the managementworkstation, those versions should be uninstalled first and Python v2.7 installed.3. [ ] For VxRail appliances connected to an External vCenter, manually remove thecluster/VDS/management accounts in the External vCenter.4. [ ] (Optional) In the vSphere Web Client, go to the Marvin-Virtual-SAN-Datastore. Click on Manageand then Files. Delete the ISO and UPGRADE directories. DO NOT delete any directories named witha UUID.5. [ ] For each VxRail host in the VxRail cluster, identify the IP address assigned to the factory-createdVMkernel management interface (vmk0) in one of the following ways:a. The IP address is displayed in the vSphere Web Client (use vcserver to locate the networkinformation for the VMkernel adapter on each ESXi host)orb. The IP address is displayed in DCUI (console user interface for ESXi)orc. ssh into each ESXi host (or connect a console or monitor via BMC) and run the esxcli networkip interface ipv4 get command on each host. The username is root. Use the password for the ESXi hosts that was set during VxRail Initial Configuration. (For an un-configured VxRail appliance, the password is Passw0rd!) The output will be similar to what is shown below:esxcli network ip interface ipv4 get | grep "vmk0"vmk0 MARVIN Management IPv4 10.10.10.5 255.255.255.0 10.10.10.25500:25:90:eb:bc:0a 1500 65535 true STATICOn an un-configured VxRail appliance, ESXi IP addresses are either assigned by DHCP (if it was available in your network) or configured as IPv4 link-local addresses (starting with 169.254.x.y). On a configured VxRail appliance, ESXi IP addresses are specified by the user who set up the appliance.6. [ ] Fill in the IPv4 address of each ESXi host in the cluster (use additional space if there is more thanone appliance in a cluster):Host IPv4 AddressESXi host on node 1ESXi host on node 2ESXi host on node 3ESXi host on node 47. [ ] From the VxRail workstation/laptop, verify that you can ping each IPv4 addressNote: If you cannot access a host, try power-cycling the node first.8. [ ] Use vSphere Client to login vCenter Server to check current Management VLAN as below:Figure 1 Example: the management VLAN ID in this appliance is 117Note: If you cannot access vCenter Server, you will have to ask the customer for the management VLAN ID.Running ResetReset is run from the VxRail workstation/laptop, using the options described in the Reset Command Options section. Before running Reset, be sure to read the section on Best Practices and Troubleshooting so that you can use the Reset script correctly.Note: Using the --vlan option for Reset is recommended even if current management VLAN is not set ( in this case, use 0 for VLAN ID). It will modify the management VLAN ID saved in configBundle first before actually using the configBundle. It simplifies initial setup because the management VLAN ID is configured on all 4 ESXi hosts. Likewise, the --initialIpAddress,--initialSubnet, and --initialGateway options also simplify initial setup.Another benefit comes when a VxRail appliance is reset and remains in the same environment (I.e. It is not relocated to another network). In this case, retaining the management VLAN ID and initial IP information during a reset permits the VxRail Manager workstation/laptop to remain set for the correct VLAN and IP. If these options are not used, the instructions in the VxRail SetupGuide can be followed at a later time.If the VLAN option is not used, no changes will be made to the Management VLAN settings. It will remain exactly as previously set.All appliances and nodes in a VxRail cluster should be reset if one appliance or node needs to be reset. Use the following procedure:•If you have more than one appliance in your VxRail cluster, reset each secondary appliance, one at a time. We recommend that the secondary appliances be reset in the order in which they were added to the cluster. Power off all nodes after each appliance is reset.•If you only have one appliance in the VxRail cluster, or when you have finished resetting and shutting down all secondary appliances, reset the primary appliance.Example using Reset on Windows1. [ ] To reset the appliance use the following command:Example:C:\Python27\python.exe c:\reset\reset.pyc -d --destroyAllVMs -f <IPv4_node1> -a <IPv4_node2> -a <IPv4_node3> -a <IPv4_node4> --vlan <vlan_id>[ --initialIpAddress=<init_IPaddr> --initialSubnet=<init_netmask>--initialGateway=<init_gateway> ]After ResetNote: The password is now Passw0rd! for all ESXi hosts, vCenter Server Appliance, and VxRail Manager.1. [ ] For VxRail appliances connected to an External vCenter, manually remove thecluster/VDS/management accounts in the External vCenter.2. [ ] Point a browser to the VxRail Manager user interface to begin VxRail initial configuration followingthe instructions in “VxRail Initial Configuration” in the VxRail Setup Guide. The location is one of the following:<init_IPaddr>specified in the ‘--initialIpAddress’ option supplied to Resetorhttps://192.168.10.200, the default value for ResetIf you cannot reach VxRail at one of these IP addresses after Reset, follow the instructions in AppendixA to configure another initial IP address.Reset Command OptionsBest Practices and TroubleshootingResetting Clusters with Multiple AppliancesIf you want to restore a multi-appliance VxRail cluster:After performing initial configuration on the primary appliance in the VxRail cluster, power on and configure each secondary appliance, one at a time. The primary appliance will discover each secondary appliance when it is powered on. Then you will add it to the cluster before continuing with the next secondary appliance. For more information, including configuring the Management VLAN, see the VxRail Setup Guide, “Adding Appli ances to a VxRail Cluster”.If you want to separate the appliances into multiple VxRail clusters:When you run Reset on each appliance, assign a unique <init_IPaddr> with the ‘--initialIpAddress’option. Then point your browser to each <init_IPaddr> and run VxRail initial configuration to create separate VxRail clusters.Reset Output: Example output of Successful reset:Reset succeeds with INFO and WARNING output similar to the following:c:\Python27\python.exe reset.py -d --destroyAllVMs -f 10.10.10.11 --initialIpAddress=10.10.10.250 --initialSubnet=255.255.254.0--initialGateway=10.10.10.253 -a 10.10.10.12 -a 10.10.10.13 -a 10.10.10.14 Post-configuration Password:INFO Primary node supplied: 10.10.10.11 INFO Secondary node supplied:10.10.10.12 INFO Secondary node supplied: 10.10.10.13 INFO Secondary nodesupplied: 10.10.10.14INFO MARVIN VIB 3.x discovered on hostsVxRail 3.x WARNING================================================WARNING THE FOLLOWING ARE THE CURRENTLY REGISTERED VIRTUAL MACHINES:WARNING ['VMware vCenter Server Appliance', 'VxRail Manager', 'VMware vRealize Log Insight'] WARNING CONTINUING WILL DESTROY ALL VIRTUAL MACHINES REGISTERED WITH THE APPLIANCE.CONFIRM (YES/NO): YESWARNING DESTROYING ALL VMs ON 10.10.10.11: ['VMware vCenter Server Appliance', 'VxRail Manager', 'VMware vRealize Log Insight']…INFO Host 10.10.10.11 has VMs [] remaining. INFO Removing hosts from VSAN cluster.INFO Putting hosts in maintenance mode. INFO Resetting and rebooting hosts.INFO Waiting for hosts to finish rebooting to confirm reset ...…INFO Trying to connect to 10.10.10.14 ...INFO Host 10.10.10.14 not yet available, still waiting ... INFO Trying to connect to 10.10.10.14 ...INFO Connection to host 10.10.10.14 successful.INFO Regenerating VSAN and VMs on primary node (10.10.10.11). Assuming default password. INFO Deploying VM: VMware vCenter Server Appliance fromimages/vcsa-restore-original/.INFO Deploying VM: VxRail Manager from images/evorail-restore-original/. INFO Upgrading hardware on VM: VMware vCenter Server ApplianceINFO Enabling Ivy Bridge EVC for VM: VMware vCenter Server Appliance INFO Upgrading hardware on VM: VxRail ManagerINFO Enabling Ivy Bridge EVC for VM: VxRail ManagerINFO Setting VM AutostartInfo for: VxRail manager on 10.10.10.11. INFOstartAction: powerOn; stopAction: guestShutdownINFO Powering on VM: VxRail ManagerINFO Deploying VM: VMware vRealize Log Insight fromimages/log-insight-original/. INFO Reconfiguring VM 'VMware vRealize Log Insight' OVF environment: success.INFO Upgrading hardware on VM: VMware vRealize Log InsightINFO Enabling Ivy Bridge EVC for VM: VMware vRealize Log Insight INFO Restarting 'loudmouth'.INFO Finalizing settings on Shamu.Reset FailureReset can fail for a variety of reasons. If it does not complete successfully on all nodes in an appliance, it can be rerun just on the node(s) that did not reset properly.Infrequently, Reset can report a failure but eventually succeed. This can happen if an ESXi host takes longer to reboot than the 720-second timeout in Reset. The ESXi node can still continue to boot and it may finally succeed. You can determine whether or not an ESXi host was successfully reset by attempting to login in via ssh or DCUI. The password should have been reset to Passw0rd!If you cannot login with this default password, the host was NOT reset properly. Run Reset again only on the host that did not boot successfully.Another reason that Reset could fail is if the IPv4 address for vmk0 does not match the information saved in configBundle.tgz. This would happen if ESXi was assigned a static IP address instead of link-local DHCP after configBundle.tgz was created, but before initial configuration. The failure message displayed would indicate failure to connect to all hosts.Usin g the ‘--onlyRegeneratePrimary’ option will quickly redeploy the service VMs.Note: Since you have already reset the appliance, the default password, Passw0rd!, must be used instead of your original password.C:\Python27\python.exe c:\reset\reset.pyc -f <IPv4_node1>--onlyRegeneratePrimary --initialIpAddress=<init_IPaddr>--initialSubnet=<init_netmask> --initialGateway=<init_gateway>The reasons that Reset can fail include the following:•Failing to connect to or locate a specified ESXi host•Using an invalid IPv4 address as Reset command options•Having a proxy server configured on the VxRail workstation/laptop•Failing to deploy the Log Insight VM or VxRail Manager•Still failing after several automatic retriesKnown IssuesIf you have a typo on the Reset command line, such as using a space instead of ‘=’ in the option/value pairs that require one (--initialIpAddress, --initialSubnet, --initialGateway), all 3 options will be ignored. (e.g--initialIpAddress=10.10.10.200 is correct; --initialIpAddress 10.10.10.200 is incorrect) If Reset otherwise succeeds, you can follow the instructions in Appendix A to set the initial IP address.Appendix A: VxRail Appliances with a Custom Initial IP address WARNING: The following steps are to configure a custom IP address for initial access to VxRail if you cannot use the <init_IPaddr> specified in the ‘--initialIpAddress’ option or the default IP address, 192.168.10.200.Note: You are setting the IP address for the VxRail Manager in Release 4.0.1. [ ] Connect the vSphere (C#) Client to the IP address of ESXi host 1 using the root user and thepassword that Reset configured during ESXi software installation, Passw0rd!2. [ ] Click the Virtual Machines tab and select “VxRail Manager”. The VM should already be poweredon. If not, click the green play button to power it on and wait for it to boot.3. [ ] Open the Console and login as root with the default password Passw0rd!4. [ ] Stop vmware-marvin:/usr/bin/systemctl stop vmware-marvin.service5. [ ] Using the vami_set_network command, change the default IP address to a custom IP address,netmask, and gateway using the following syntax (all arguments are required)./opt/vmware/share/vami/vami_set_network eth0 STATICV4 <init_IPaddr><init_netmask> <init_gateway>6. [ ] Start vmware-marvin and restart loudmouth on VxRail Manager:/usr/bin/systemctl start vmware-marvin.service/usr/bin/systemctl restart vmware-loudmouth.service7. [ ] Restart loudmouth on the primary ESXi host:/etc/init.d/loudmouth restart。
VxRail超融合平台常见问题解答
目录
发布
订购
技术
管理
网络
销售 合作伙伴 定价 超级融合基础架构市场 支持
年月
发布
问: 什么是
应用装置?
答:
应用装置是由
它是建立完全虚拟化的
和
独家提供的超级融合应用装置,而且
环境的最简单、最快捷的途径。
问:
应用装置有何好处?
答:
为范围广泛的一系列应用程序和工作负载提供了简单、经济高效的超级融合解决
答: 我们不会因为您选择使用应用装置而影响您的
工具和流程,包括与
堆栈集成的
是
、
和或
客户都已经具备的工具。
体验。您可以使用您熟悉的现有 。用于管理存储的门户 。这些是多数
问:
应用装置是怎样管理的?
答:
应用装置通过
软件提供的单一控制台进行管理,此控制台集成了
支持
与其他可维护性功能的
和
。另外,在
中可以发现和显示
答: 对于
、 和 ,每个节点需要 个
网络连接。一个填满的应用装
置将需要 个以太网连接。对于
,每个节点需要 个
连接,共达
仅供内部和合作伙伴使用
年月
个连接。如果客户希望使用可选的
管理端口,则每节点另需一个
连接来连接到客户的管理网络。
和
端口速度不受支持。
问:
应用装置是否支持
网络?
答: 支持。
应用装置可以安装在
单步骤即可完成这些操作 从预定义的 规模中选择大、中、小的规模,然后指定来
宾操作系统、虚拟局域网
、安全选项及数据保护等具体细节。通过消除 多个
EMCVxRail超融合平台-性能测试报告
EMCVxRail超融合平台-性能测试报告EMCVxRail超融合平台性能测试报告⽬录Contents1.测试⼯作准备 (3)1.1.测试⼯具介绍 (3)1.2.测试环境介绍 (3)1.3.测试项⽬ (4)1.4.测试参数设置 (5)2.测试结果 (9)2.1.供参考数据 (11)1.测试⼯作准备1.1.测试⼯具介绍本次测试选⽤Iometer进⾏测试;Iometer是⼀个单机或者集群的I/O⼦系统的测量和描述⼯具。
它最初是由英特尔公司在1998年2⽉17⽇的英特尔开发者论坛(IDF)宣布,⾃那时以来,在⾏业内⼴泛的蔓延,成为了标准。
Iometer包括2个程序,Iometer.exe和Dynamo.exe。
其中Iometer是控制程序,是图形界⾯,让你轻松的调节参数和显⽰测试结果,⽽Dynamo就是让测试盘产⽣压⼒测试的主程序了,⽤Iometer来控制Dynamo程序。
在Windows下运⾏Iometer时,会⾃动打开Dynamo程序。
测试⼯具版本为iometer-1.1.0-win64.x86_64-bin。
1.2.测试环境介绍环境中数据库以虚拟机⽅式运⾏在VMware虚拟化环境中,拓扑结构如下:... ...EMC VxRAIL其中VxRail 超融合设备内置4个服务器节点,每个节点配置1块800GBSSD 盘和5块2TBSATA 盘,共4块800GBSSD 盘和20块2TBSATA 盘。
针对超融合架构,我们在每个节点部署2个Windows 2008R2虚机,并安装 IOmeter 软件,测试的虚拟机配置2×4颗处理器核⼼,32GB 内存和80GB 系统盘,100GB 数据盘。
本次测试针对该虚拟机数据盘磁盘⽂件进⾏性能测试。
利⽤IOmeter ⽣成特定负载,在 VxRailManager 观察系统负载情况,并收集 IOmeter 详细结果。
1.3. 测试项⽬1.4.测试参数设置本次测试使⽤8个CPU核⼼,对应图中Topology栏内Worker1-8,对所有Worker均设置相同参数;DiskTargets栏中选择相应磁盘(这⾥选择E:,图中标⽰有误),MaximumDiskSize保持默认为0(图中标⽰有误),其他参数均保持为默认;AccessSpecifications栏中指定IO类型,其中测试⼀和测试⼆已有现成的对应规则,测试三需要编辑修改Default规则;点击编辑进⼊规则编辑页⾯,将TransferRequestSize设置为8KB,其他保持不变,该IO类型即为Oracle数据库IO类型;ResultDisplay栏中UpdateFrequency保持默认5s采集⼀次数据;TestSetup栏中RunTime设置为5分钟;2.测试结果(详细结果见《EMC VxRail 性能测试详细结果》)测试⼀:最⼤IO处理能⼒测试四:常规应⽤顺序读:测试五:常规应⽤随机读:测试六:常规应⽤顺序写2.1.供参考数据。