IBM小型机微码升级详细的升级过程

微码升级详细的升级过程如下:Special Instructions for Models 9117-570, 9116-561 and 9406-570下面三个菜单是让你确认设备配置是否给Deconfigured 。

是做升级微码前的准备确认工作。

Model 9117-570, 9116-561 and 9406-570 systems with any level of SF240 installed must be checked for GARDed out nodes, processors and memory before applying a new level of SF240 firmware. Following are instructions to determine if any nodes, processors or memory is GARDed out. If any hardware resource are found to be GARDed, contact your next level of support and have the situation corrected before applying this service pack.1. Log on to ASM as "admin".2. Click on the "Expand all menus" link to make all options visible.3. Navigate down to the options under "System Configuration" followed by "Hardware Deconfiguration".4. Click on the link "Processor Deconfiguration" to bring up the page that shows the number of processors present and whether or not they areconfigured.5. Click on the link "Memory Deconfiguration" to bring up the page thatshows the total amount of memory present and if any is presentlydeconfigured.6. Click on the link "Processing unit Deconfiguration" to bring up thepage that shows the processing units in the system and if any ispresently deconfigured.7. Log off.从IBM官网下载最新的01SF240_338_201版本的微码,文件下载下来是一个rpm包,01SF240_338_201.rpm,FTP 到AIX系统上找到AIX下微码的目录,进入,在命令行下运行命令:rpm -Uvh --ignoreos 01SF240_338_201.rpm微码文件会被解压到/tmp/fwupdate目录下,文件名是01SF240_338_201到/tmp/fwupdate目录下,运行命令:/usr/lpp/diagnostics/bin/update_flash -f 01SF240_338_201系统提示如果要继续更新微码需要重新启动,按下1并回车,机器重新启动并自动进入微码更新进程在更新过程中液晶面板会有CA2799FD 和CA2799FF 交替显示,更新完毕后系统自动关机,然后启动。

IBM P260和P460刀箱CMM模块微码升级,配置文件备份与还原图文说明详细步骤

IBM P260和P460刀箱CMM模块微码升级,配置文件备份与还原图文说明详细步骤

CMM模块配置文件备份步骤
选择此项
此文档献给那些苦B 的IBM 一线SSR,我们实践中锻炼成长,在点滴积累中增长知识,在艰苦环境中成就事业 。
IBM power一线工程师技术知识库
选择此项
此文档献给那些苦B 的IBM 一线SSR,我们实践中锻炼成长,在点滴积累中增长知识,在艰苦环境中成就事业 。
此文档献给那些苦B 的IBM 一线SSR,我们实践中锻炼成长,在点滴积累中增长知识,在艰苦环境中成就事业 。
IBM power一线工程师技术知识库
此文档献给那些苦B 的IBM 一线SSR,我们实践中锻炼成长,在点滴积累中增长知识,在艰苦环境中成就事业 。
点击进入微码升级
此文档献给那些苦B 的IBM 一线SSR,我们实践中锻炼成长,在点滴积累中增长知识,在艰苦环境中成就事业 。
IBM power一线工程师技术知识库
选择本地
此文档献给那些苦B 的IBM 一线SSR,我们实践中锻炼成长,在点滴积累中增长知识,在艰苦环境中成就事业 。
我这里把文件保存到了桌面上
此文档献给那些苦B 的IBM 一线SSR,我们实践中锻炼成长,在点滴积累中增长知识,在艰苦环境中成就事业 。
IBM power一线工程师技术知识库
保存后的文件
此文档献给那些苦B 的IBM 一线SSR,我们实践中锻炼成长,在点滴积累中增长知识,在艰苦环境中成就事业 。
P260/460刀箱CMM模块微码升级,配置文件 备份与还原步骤
此文档献给那些苦B 的IBM 一线SSR,我们实践中锻炼成长,在点滴积 累中增长知识,在艰苦环境中成就事业 。
• 更换Pure Flex的CMM模块是一件说难不难说容 易也不容易的事情,如果赶上点背新旧模块无法 同步那就是一件很痛苦的事。 • 如果更换后手动重新配置CMM是比较费时费力的, 而且还容易出错。CMM本身带有配置文件备份我 们可以充分利用这个便利的小功能叫我们的工作 变得更轻松

ATTO 6500 微码升级文档

ATTO 6500 微码升级文档

ATTO6500 微码升级文档ATTO升级微码可通过三种方式:1.图形界面网页方式、2. FTP方式、3. 串口方式。

操作前需要进行初始配置步骤,通过QuickNAV软件完成。

默认的管理账户为root/Password(大小写敏感)。

0.配置步骤通过网线直连工作电脑和桥设备的“management 1”管理端口。

QuickNAV软件无需安装,点击直接运行。

程序通过广播包找到ATTO 桥设备:此时即可配置其管理IP:重启后,即可启动浏览器,通过管理IP 访问ExpressNAV GUI :默认的管理账户为root/Password(大小写敏感):设备的状态信息展示:1.通过图形界面网页方式通过图形化界面方式升级微码较为简单,步骤如下:1.网页登录ATTO配好的IP。

2.点击“Firmware Update”选项卡。

3.点击“浏览”,选择微码文件。

4.点击Upload按钮。

5.等待系统自动完成文件上传和更新。

6.点击“Restart”选项卡,重启设备。

系统固件升级界面如下:原版文档中的描述如下:Using ExpressNAV1 If you are not already in the ExpressNAV interface, type the IP address of your FibreBridge, type in your user name and password, and click OK.2 Click on the Firmware Update menu item on the left-hand side of the page.3 The Firmware Update page appears. Click Browse to locate the firmware you downloaded earlier.4 Highlight the file.5 Click Upload.6 Wait until a new page is displayed that shows the status of each step of the download. Result: Upon successful completion of the Flashing Firmware process, a notice will appear at the bottom of the page along with a 'Restart' button.7 Click the Restart button to load and execute the firmware flashed in step 6 above. Result: Restarting Firmware page will appear and count down, returning you to the Status page.8 It is highly recommended that you repeat the firmware update processso that the backup image is replaced with up-to-date firmware.2.通过FTP方式通过FTP方式升级微码时,需要预先配置好ATTO的IP,并连接网线至“management 1”管理端口。

IBM P服务器微码刷新最佳实践

IBM P服务器微码刷新最佳实践

IBM P服务器微码刷新最佳实践所有 IBM p 系列的服务器都有系统固件(Firmware),它存在于服务器的服务处理器(Flexible ServiceProcessor, FSP)的闪存中。

IBM会在其固件发布网站上定期发布一些固件服务包,这些服务包能够让服务器更加稳定、高效的运转,发挥其潜在的功能。

因此,升级服务器系统固件就成为系统管理员要熟练掌握的重要技术。

由于固件是服务器运转的基石,如果固件在升级过程中出现问题,则可能导致服务器故障或瘫痪。

IBM p 系列服务器在不同管理环境下的固件升级方法,根据服务器部署环境的不同,分为以下三个部分。

1. 通过 Hardware Management Console(HMC)升级服务器系统固件2. 通过 Integrated Virtualization Manager(IVM) 升级服务器系统固件3. 通过操作系统(AIX 或 Linux)升级服务器系统固件系统固件概述固件又称微码或许可内码(Licensed Internal Code),是指经过 IBM 授权的内部程序,用于解决服务器已有的问题,或者是引入新的系统功能特性。

固件为服务器提供了最基本的运行支持,对服务器的正常运行具有至关重要的作用。

系统固件命名规则IBM p 系列服务器从 POWER5 开始遵循比较统一的系统固件命名规则,其命名格式为:PPNNXXX_YYY_ZZZ其中,PP:用来标识固件所适用的子系统。

系统固件子系统的识别符为 "01", 电源子系统固件的子系统识别符为 "02"。

本文所描述的对象是系统固件。

NN:用来区分固件适用的服务器类型。

例如:"SF" 是针对 POWER5 的机器;"EL" 是针对 POWER6 的低端服务器;"EM" 是针对 POWER6 的中端服务器;"EH" 是针对 POWER6的高端服务器。

hp bl460c网卡微码与驱动升级操作

hp bl460c网卡微码与驱动升级操作

Hp bl460c 刀片服务器升级固件微码及网卡驱动程序实施步骤升级刀片iLo 3固件通过secucre sftp工具,将d:\bl460目录上传到主机tmp目录。

运行CP016203.scexe程序,升级ilo3固件firmware从版本1.28升级到版本1.50. 。

升级时候,hp bl460c刀片服务器上蓝灯闪亮,升级完成后蓝灯灭。

升级刀片NC553i固件重启刀片服务器用OneConnect-Flash-4.1.450.16程序引导,然后按照提示升级固件firmware即可。

运行reboot命令重启刀片服务器。

升级NC553i网卡驱动程序、修改网卡绑定1.rpm -ivh /tmp/bl460/hp-be2net-4.1.450.7-2.src.rpm2.rpmbuild -bb ~/rpmbuild/SPECS/hp-benet.kmp.spec3.rpm -q kmod-hp-be2net* --查询是否有旧的包,有就删除4.rpm -ivh /root/rpmbuild/RPMS/x86_64/kmod-hp-be2net-4.1.450.7-2.x86_64.rpm5.modinfo be2net | grep version6.modprobe be2net7.vi /etc/modprobe.d/dist.conf ,添加alias eth0 be2netalias eth1 be2net并注销以下两行:#alias bond0 bonding#options bonding mode=1 miimon=2008.在/etc/sysconfig/network-scripts/ifcfg-bond0文件内添加一行echo "BONDING_OPTS=\"mode=1 miimon=100\"" >> /etc/sysconfig/network-scripts/ifcfg-bond09.# service network restart -重启网卡服务进程10.#ifconfig –a --查询网卡是否都已经正常UP。

HBA卡微码升级

HBA卡微码升级

今天做了一次在小型机上升级HBA卡的微码的工作,在升级前,要检查小型机的HBA卡的型号,这个型号可以从小型机硬件配置文档里查找;其次,要确定当前HBA卡的版本,可以用如下的命令查看:--查看系统当前所有的HBA卡:test_db:/@root>#lsdev -C | grep fcsfcs0 Available 09-08 FC Adapterfcs1 Available 0E-08 FC Adapter--查看HBA卡微码的版本,注意lscfg命令的Z9字段,那里即为微码版本信息:test_db:/etc/microcode@root>#lscfg -vl fcs0fcs0 U5791.001.99200CK-P2-C01-T1 FC AdapterPart Number.................80P4543EC Level....................ASerial Number...............1F4400AF85Manufacturer................001FFeature Code/Marketing ID...280BFRU Number.................. 80P4544Device Specific.(ZM) (3)Network Address.............10000000C9402F8BROS Level and ID (02881914)Device Specific.(Z0)........1001206DDevice Specific.(Z1) (00000000)Device Specific.(Z2) (00000000)Device Specific.(Z3) (03000909)Device Specific.(Z4)........FF801315Device Specific.(Z5) (02881914)Device Specific.(Z6) (06831914)Device Specific.(Z7) (07831914)Device Specific.(Z8)........20000000C9402F8BDevice Specific.(Z9)........TS1.90A4 --微码版本信息,当前版本1.90A4Device Specific.(ZA)........T1D1.90A4Device Specific.(ZB)........T2D1.90A4Device Specific.(YL)........U5791.001.99200CK-P2-C01-T1test_db:/etc/microcode@root>#lscfg -vl fcs1fcs1 U5791.001.99200CK-P2-C05-T1 FC AdapterPart Number.................80P4543EC Level....................ASerial Number...............1F4530ABC9Manufacturer................001FFeature Code/Marketing ID...280BFRU Number.................. 80P4544Device Specific.(ZM) (3)Network Address.............10000000C94441F4ROS Level and ID (02881914)Device Specific.(Z0)........1001206DDevice Specific.(Z1) (00000000)Device Specific.(Z2) (00000000)Device Specific.(Z3) (03000909)Device Specific.(Z4)........FF801315Device Specific.(Z5) (02881914)Device Specific.(Z6) (06831914)Device Specific.(Z7) (07831914)Device Specific.(Z8)........20000000C94441F4Device Specific.(Z9)........TS1.90A4 --微码版本信息,当前版本1.90A4Device Specific.(ZA)........T1D1.90A4Device Specific.(ZB)........T2D1.90A4Device Specific.(YL)........U5791.001.99200CK-P2-C05-T1--做好这些准备工作之后,就可以解压从IBM下载的升级包,但下载时注意光纤卡的型号与微码版本--然后运用如下命令开始解压,在解压的过程中,会检查当前机器的型号是否满足要求:test_db:/tmp@root>#rpm -ihv --ignoreos pci.df1000fa-1-91A5.aix.noarch.rpm Checking machine typeMachine type IBM,9119-590 is ok,proceeding with installation.pci.df1000fa##################################################--解压完成后,会在/etc/microcode目录下生成一个文件df1000fa.191105(如果你升级到其它版本,文件名是不一样的)test_db:/etc/microcode@root>#ls -ltotal 13408-r--r--r-- 1 root system 20176 Jul 08 2004 cx_conc-r--r--r-- 1 root system 20768 Jul 08 2004 cx_e_conc-r--r--r-- 1 root system 28672 Jul 08 2004 cxpabios-r--r--r-- 1 root system 36864 Jul 08 2004 cxpafep-rwxr-xr-x 1 root system 664748 Jul 27 2006 df1000fa.191105 --新HBA 微码文件-r-xr-xr-x 1 bin bin 99995 Jun 17 2004 dgr0871014d.00.00-r-xr-xr-x 1 bin bin 197089 Jun 22 2004 dgr0b91014d.00.00-r-xr-xr-x 1 bin bin 267973 Jun 22 2004 dgr0c91014d.00.00-r-xr-xr-x 1 bin bin 316207 Jun 17 2004 dgr0d31014d.00.00-r-xr-xr-x 1 bin bin 99095 Jun 17 2004 dgr0f81014d.00.00-r--r--r-- 1 bin bin 74920 Jun 22 2004 ec8fd.00.03-r--r--r-- 1 root system 1071532 Nov 03 2004 ibmsis2780.img-r--r--r-- 1 root system 881312 May 26 2005 ibmsis5702.img-r--r--r-- 1 root system 1244888 May 26 2005 ibmsis5703.img-r--r--r-- 1 root system 1024068 Jun 17 2004 ibmsis5709.img-r--r--r-- 1 root system 881312 May 26 2005 ibmsis570B.img-r--r--r-- 1 root system 41472 Oct 12 2006 sxbios-r--r--r-- 1 root system 31232 Jun 17 2004 sxfep--在正式升级微码前,要确定当前系统在HBA卡上没有I0。

HP服务器微码升级步骤

HP服务器微码升级步骤

HP 全系列服务器微码更新方法对于HP DL580G5 服务器的最新微码官方只提供到FW10.10的HP ProLiant Firmware Maintenance CD光盘,该微码光盘包含了全系列ProLiant服务器的硬件固件,并且该光盘中集成了固件升级软件。

HP ProLiant Firmware Maintenance CD v10.10支持升级ProLiant G7全系列之前的所有型号服务器(含x86架构BL刀片服务器)。

升级方法:1、将HP ProLiant Firmware Maintenance CD v10.10光盘放入光驱2、重启服务器按F12键,选择CD-ROM启动3、引导从光驱启动后,会启动HP ProLiant Firmware Maintenance CD v10.10光盘内自带的固件升级软件4、固件升级提供两种方式,包括自动升级和手动升级自动升级工具:是完全自动对整机硬件微码进行分析,然后选择微码光盘内最适合的微码版本进行升级,此种方法是最简单、最安全。

在自动升级工具中会自动将不匹配的微码忽略,减小了升级的风险。

手动升级工具:首先会对整机的微码进行扫描,然后列出本机的硬件,手动选择升级那些硬件的微码,选择后升级工具会对选中的硬件微码进行分析,选择出所选硬件最适合的微码版本然后进行升级。

大多数升级建议采用自动升级工具,因为有些硬件的微码是需要成套升级,自动升级会将所有硬件的微码综合分析,选择最佳微码版本,确保了升级的成功性。

5、开始升级后的过程不能中断,大约15分钟升级完成6、升级结束后服务器会自动重新启动,弹出光驱。

注意事项:1、微码升级过程中不可断电、人为终止、人为重启,否则造成硬件损坏。

2、微码升级后不可降级,无法回退。

3、微码升级软件会自动控制服务器进行重启。

USPV微码升级

USPV微码升级

USPV升级微码过程介绍
HDS存储设备微码升级不需要停机进行,支持设备在线升级方法。

因为在线升级过程中会占用部分系统资源,因此我们推荐在I/O交易量小的时候进行升级(建议安排在周六),升级总的时间约需2~3小时。

升级步骤:
1.备份当前USP-V的配置信息;
2.检查确认DKC工作状态正常,无故障部分,如果有故障部分,需要先修复才可进行微码升级工作;
3.通过远程桌面连接到SVP;
4.将微码光盘放到PC的光驱中;
5.将SVP模式修改为Modify模式,选择Install->Micro Program Install;
6.按照提示选择CDROM, online FC模式;
7.升级SVP部分;
8.再将MAIN/LCP/HTP/LCDG/FCDG/RAMBOOT/SSVP/SCHIP/CUDG4进行升级;
9.升级DKU部分;
10.再执行更新Config.
11.完成之后检查核对版本正确,保存新的配置文件.
注意:
根据HDS最新公布微码的版本情况,建议目前USPV/USPVM的版本为
60-03-28-00/00-M078;
USPV/USPVM当前微码低于60-02-48-00/12时,需要手动升级,不能使用Wizzard,升级顺序为SVP、DKC、DKU、Config;。

ibm 3650 m4微码升级

ibm 3650 m4微码升级

第一步,要按照如下方法把IMM2的IP改成下图中的规格。

启动服务器后, 可以使用BIOS设置工具管理IMM 网络连接. 开启服务器, 通电大约两分钟后, 电源控制按钮将会激活, 按下开机按钮, 就会显示IBM System x Server Firmware 欢迎界面.按下F1键. 在Setup utility主窗口中, 选择System Settings - Integrated Management Module - Network Configuration. 在DHCP Control中有三个IMM 网络连接选项(Static IP,DHCP Enabled,DHCP with Failover (default). 选择其中一种网络连接方式.如果选择static IP, 须指定IP地址,子网掩码,网关.(IP address,subnet mask and default gateway).设置完后选择Save Network Settings 保存, 退出 Setup utility.第二步,要在IBM官网上下载以下两个文件(分别是UEFI和IMM2的升级文件)第三步,升级(以下是升级过程)1.升级IMM primary和backup bank到1)网线连到服务器IMM端口和笔记本网口,笔记本网络做好如下配置,如已经做好,则跳过第一步。

2)上电开机,等待大概5-6分钟之后,IMM能ping 通。

可以通过以下步骤测试,打开CMD命令行敲入ping ,如果能连上服务器的Imm,则可以ping通,就是出现下图方框里面的信息。

3)打开浏览器窗口,地址栏输入,按下回车键4)User Name : USERID.Password : PASSW0RD(“0”是数字不是字母)输入用户名和密码(用户名及密码全是大写)之后,登陆IMM管理界面。

5)鼠标移动到Server Management,点击下面的ServerFirmware6)发现机子firmware的情况如下图所示7)点击上图的Update Firmware选项,再点击下图的Select File,找到升级imm升到的源文件,再点击打开8)成功上传会出现下面的图片,再点击next9)需要两个Action,分别刷Primary和Backup到版本,因此设置为下面图片所示,再点击next10)刷新成功后,会出现下面的图片。

小机主板微码升级过程 1

小机主板微码升级过程 1

本人亲历的升级微码详细过程(一头汗啊)先介绍一下背景信息:客户是西安市内的一家大型连锁商场,有一台Power550小型机,出现报错。

IBM POWER6 550型号:8204-E8A;序列号:XXXXXXX设备情况:2C,3.5GHz Power550,4G内存,146x4硬盘; AIX版本:6100-03-01-0921;微码版本号:EL340_075;用途:POS机数据备份。

分析过程:1、机器前面板显示报错B181F126,当前的FW是340-075。

从错误日志上看是一个未知的系统平台错误。

2、联系IBM工程师被告知可能是微码问题或机器主板问题,建议先升级系统微码,然后观察,如果继续报错就的更换主板了。

3、经过IBM工程师确认,“建议您升级机器的fw到340的最新版即可解决,该错误属于fw误报,不会对机器运行产生任何影响。

”操作过程我先去IBM网站下载合适的微码版本(http://www-/support.fixcentral/)发现有2个版本:Power6 System Firmware EL340_122、Power6 System Firmware EL340_132,都下载下来,计划安装132版本。

经过和客户交流,发现前面板无HMC的连接,在服务器上没有保留与HMC连接的记录信息,OK,升级变简单了。

一、首先查看目前微码的版本AIX Version 6Copyright IBM Corporation, 1982, 2009.login: rootroot's Password:************************************************************** ****************** ** ** Welcome to AIX Version 6.1! ** ** ** Please see the README file in /usr/lpp/bos for information pertinent to * * this release of the AIX Operating System. ** ** *************************************************************** *****************Last unsuccessful login: Sun Mar 13 22:56:39 GMT+08:00 2011 on/dev/pts/1 from 192.168.20.64Last login: Sun Mar 13 23:58:53 GMT+08:00 2011 on /dev/pts/1 from 192.168.20.64# lsmcode -cThe current permanent system firmware image is SF340_075The current temporary system firmware image is SF340_075The system is currently booted from the permanent firmware image.二、将微码的RPM文件上传到/tmp/fwupdate目录中,用FTP工具的BIN模式。

AIX微码升级全过程

AIX微码升级全过程

AIX微码升级全过程首先是把微码补丁从IBM网站下到个人电脑里(微码下载地址:/webapp/set2/firmware/gjsn),假设该文件为123.bin并储存在C盘根目录下,然后进入小机的cd /tmp目录,在用LS命令查看该目录下的所有文件:# cd /tmp# ls.X11-unix aaa.jlfEa baaNDlfMb dpi_socket reconfig1.ctinst.log aaaM9lfMa baaajlfEb lost+found reconfig2.sr_migrate.log aaat2jwaa baau1jwab .out reconfig3.strload.mutex auiml.tmp bos .serial.out xlogfile再在该目录下创建firmware文件夹,在用ls命令查看是否创建成功。

# mkdir firmware# ls.X11-unix aaa.jlfEa baaNDlfMb dpi_socket .serial.out xlogfile.ctinst.log aaaM9lfMa baaajlfEb firmware reconfig1.sr_migrate.log aaat2jwaa baau1jwab lost+found reconfig2.strload.mutex auiml.tmp bos .out reconfig3文件创建成功。

然后在个人电脑的运行中进“ftp”,进入到cd /tmp/firmware目录下,ftp> cd /tmp/firmware再用lcd命令进入补丁存放的当前目录(我们前面说过补丁存在C盘根目录下)。

ftp> lcd C:\二进制传输模式执行传输ftp> bin200 Type set to I.然后使用PUT命令把补丁从C盘中复制到小机的cd /tmp/firmware文件夹中ftp> put 123.bin然后进入小机的cd /tmp/firmware目录,再LS查看是否复制成功。

HBA卡微码升级

HBA卡微码升级

今天做了一次在小型机上升级HBA卡的微码的工作,在升级前,要检查小型机的HBA卡的型号,这个型号可以从小型机硬件配置文档里查找;其次,要确定当前HBA卡的版本,可以用如下的命令查看:--查看系统当前所有的HBA卡:test_db:/@root>#lsdev -C | grep fcsfcs0 Available 09-08 FC Adapterfcs1 Available 0E-08 FC Adapter--查看HBA卡微码的版本,注意lscfg命令的Z9字段,那里即为微码版本信息:test_db:/etc/microcode@root>#lscfg -vl fcs0fcs0 U5791.001.99200CK-P2-C01-T1 FC AdapterPart Number.................80P4543EC Level....................ASerial Number...............1F4400AF85Manufacturer................001FFeature Code/Marketing ID...280BFRU Number.................. 80P4544Device Specific.(ZM) (3)Network Address.............10000000C9402F8BROS Level and ID (02881914)Device Specific.(Z0)........1001206DDevice Specific.(Z1) (00000000)Device Specific.(Z2) (00000000)Device Specific.(Z3) (03000909)Device Specific.(Z4)........FF801315Device Specific.(Z5) (02881914)Device Specific.(Z6) (06831914)Device Specific.(Z7) (07831914)Device Specific.(Z8)........20000000C9402F8BDevice Specific.(Z9)........TS1.90A4 --微码版本信息,当前版本1.90A4Device Specific.(ZA)........T1D1.90A4Device Specific.(ZB)........T2D1.90A4Device Specific.(YL)........U5791.001.99200CK-P2-C01-T1test_db:/etc/microcode@root>#lscfg -vl fcs1fcs1 U5791.001.99200CK-P2-C05-T1 FC AdapterPart Number.................80P4543EC Level....................ASerial Number...............1F4530ABC9Manufacturer................001FFeature Code/Marketing ID...280BFRU Number.................. 80P4544Device Specific.(ZM) (3)Network Address.............10000000C94441F4ROS Level and ID (02881914)Device Specific.(Z0)........1001206DDevice Specific.(Z1) (00000000)Device Specific.(Z2) (00000000)Device Specific.(Z3) (03000909)Device Specific.(Z4)........FF801315Device Specific.(Z5) (02881914)Device Specific.(Z6) (06831914)Device Specific.(Z7) (07831914)Device Specific.(Z8)........20000000C94441F4Device Specific.(Z9)........TS1.90A4 --微码版本信息,当前版本1.90A4Device Specific.(ZA)........T1D1.90A4Device Specific.(ZB)........T2D1.90A4Device Specific.(YL)........U5791.001.99200CK-P2-C05-T1--做好这些准备工作之后,就可以解压从IBM下载的升级包,但下载时注意光纤卡的型号与微码版本--然后运用如下命令开始解压,在解压的过程中,会检查当前机器的型号是否满足要求:test_db:/tmp@root>#rpm -ihv --ignoreos pci.df1000fa-1-91A5.aix.noarch.rpm Checking machine typeMachine type IBM,9119-590 is ok,proceeding with installation.pci.df1000fa##################################################--解压完成后,会在/etc/microcode目录下生成一个文件df1000fa.191105(如果你升级到其它版本,文件名是不一样的)test_db:/etc/microcode@root>#ls -ltotal 13408-r--r--r-- 1 root system 20176 Jul 08 2004 cx_conc-r--r--r-- 1 root system 20768 Jul 08 2004 cx_e_conc-r--r--r-- 1 root system 28672 Jul 08 2004 cxpabios-r--r--r-- 1 root system 36864 Jul 08 2004 cxpafep-rwxr-xr-x 1 root system 664748 Jul 27 2006 df1000fa.191105 --新HBA 微码文件-r-xr-xr-x 1 bin bin 99995 Jun 17 2004 dgr0871014d.00.00-r-xr-xr-x 1 bin bin 197089 Jun 22 2004 dgr0b91014d.00.00-r-xr-xr-x 1 bin bin 267973 Jun 22 2004 dgr0c91014d.00.00-r-xr-xr-x 1 bin bin 316207 Jun 17 2004 dgr0d31014d.00.00-r-xr-xr-x 1 bin bin 99095 Jun 17 2004 dgr0f81014d.00.00-r--r--r-- 1 bin bin 74920 Jun 22 2004 ec8fd.00.03-r--r--r-- 1 root system 1071532 Nov 03 2004 ibmsis2780.img-r--r--r-- 1 root system 881312 May 26 2005 ibmsis5702.img-r--r--r-- 1 root system 1244888 May 26 2005 ibmsis5703.img-r--r--r-- 1 root system 1024068 Jun 17 2004 ibmsis5709.img-r--r--r-- 1 root system 881312 May 26 2005 ibmsis570B.img-r--r--r-- 1 root system 41472 Oct 12 2006 sxbios-r--r--r-- 1 root system 31232 Jun 17 2004 sxfep--在正式升级微码前,要确定当前系统在HBA卡上没有I0。

9133-55A微码升级技术方案

9133-55A微码升级技术方案

9133 55A微码升级技术解决方案适用范围:适用于P5系列的IBM小型机微码的升级主要技术步骤:1.查看当前的微码:#lsmcodeThe current permanent system firmware image is SF220_005. 永久性的firmwareThe current temporary system firmware image is SF220_006. 临时性的firmwareThe system is currently booted from the temporary image. 当前使用的firmware 2.把RPM文件拷入/tmp/fwupdate目录#ls /tmp/fwupdate01SF240_299_201.rpm3. 解压#rpm -Uvh --ignoreos /tmp/fwupdate/01SF240_299_201.rpmNote: When you unpack the RPM file, the server firmware update file is saved in the /tmp/fwupdate directory on the server's hard drive in the followingformat: 01SF2xx_yyy_zzz.4.查看解压后的文件(多了一个01SF240_299_201)#ls /tmp/fwupdate01SF240_299_201.rpm01SF240_299_2015.安装firmwareTo install the server firmware update, choose from the following options:enter the following at an AIX command prompt:#cd /tmp/fwupdate#/usr/lpp/diagnostics/bin/update_flash -f 01SF240_299_2016.再次较验一下微码,查看是否已经安装上lsmcodeThe current permanent system firmware image is SF235_214The current temporary system firmware image is SF240_299The system is currently booted from the temporary image.7.更新为永久性的firmwarea:第一种方法Using the flash commandAt an AIX command prompt, type the following:#/usr/lpp/diagnostics/bin/update_flash -cThe update_flash -c command might run for 10 or more minutes.After the update completes, choose from the following options:If you are committing a firmware update level that begins with SF220, use the manual process to shut down and restart the server. This ends the procedure.If you are committing a firmware update level that begins with SF222 or higher, there is no need to shut down and restart the server. This ends the procedure.Using the AIX diagnostic service aidsb:第二种方法At the AIX command prompt, type diag.Initialize the terminal type, if requested.On the function selection screen, select Tasks and Service Aids.On the task selection screen, scroll to the bottom of the list of options, and select Update and Manage Flash. A screen similar to the following is displayed:UPDATE AND MANAGE SYSTEM FLASHThe current permanent system firmware image is SF235_214The current temporary system firmware image is SF240_299The system is currently booted from the temporary image.Validate and Update System FirmwareUpdate System FirmwareCommit the Temporary ImageSelect Commit the Temporary Image, and press Enter. The process might run for 10 or more minutes.After the update is complete, choose from the following options:If you are committing a firmware update level that begins with SF220, use the manual process to shut down and restart the server. This ends the procedure.If you are committing a firmware update level that begins with SF222 or higher, there is no need to shut down and restart the server. This ends the procedure.注意问题整个微码升级的过程中严禁断电,掉电。

升级AIX系统微码

升级AIX系统微码

升级AIX系统微码升级系统微码一、获得现在机器的微码#lscfg -vp|grep alterable --find the system microcode level 查看机器微码ROM Level.(alterable).......M2P060505_condor_ 系统电源控制网络版本SPCNROM Level.(alterable).......0000CMD02252 服务处理器(Service Processor FW)的版本ROM Level.(alterable).......CM060505 firmware level (installed firmware)的版本可通过SMS获得 3. System Information Menu ----1. Read VPD Images from Last System Boot---30. Platform Firmware-----RM ...................... CM060505 CM060505或#prtconf |morePlatform Firmware level: CM060505二、获得机器的型号# prtconf |grep 'System Model'System Model: IBM,7026-H80#lsattr -El sys0 |grep modelname三、下载微码软件/doc/216969173.html,/server/mdownl oad/download.html选择对机型选择system Firmware中的AIX注:Desc (Instructions document)AIX (For downloading to an AIX server or system)DOS (For downloading to a Windows workstation)一定要注意看Desc文档的说明(在下载行的最后一列),告诉你操作步骤及注意事项、命令、firmware文件大小等重要信息。

升级微码总结

升级微码总结
The current permanent system firmware image is SF222_081
The current temporary system firmware image is 0000
The system is currently booted from the permanent firmware image.
ftp> cd /tmp/fwupdate
250 CWD command successful.
ftp> pwd
257 "/tmp/fwupdate" is current directory.
ftp> bin
200 Type set to I.
ftp> bin
200 Type set to I.
注意:此选项不会要求确认,除非你确定要这样做,否则不要选择此项
这个过程将会运行10分钟左右,成功完成之后,如果提交的微码版本是SF220,那么需要手动关机,并重新启动机器,如果提交的微码版本是SF222或更高,就不需要关机和重启了。使用命令#lsmcode查看当前的微码
The current permanent system firmware image is 01SF240_338
ftp> put 70286C4F.BIN
200 PORT command successful.
150 Opening data connection for 70286C4F.BIN.
226 Transfer complete.
ftp: 发送 4430377 字节,用时 0.97Seconds 4572.11Kbytes/sec.

brocade DCX 几种微码升级方法总结

brocade DCX 几种微码升级方法总结

brocade DCX 几种微码升级方法总结BROCADE DCX 微码升级注意事项: 1、在微码升级之前,务必先备份好当前的配置信息; 2、尽管 Brocade 交换机支持在线进行微码升级,但是,如果有条件停机的话,建议离线进行升级。

(在实际升级的时候,发现升级切换 CP 的时候,全部端口会闪亮一次黄灯,端口状态在 log 中会发现有断开的记录;之后用光纤线连接交换机跟存储,再进行升级操作和手动切换 CP 板进行测试,在 log 中发现连接有光纤线的端口在此过程中没有断开的记录。

)一 U 盘升级DCX 随机器附带的 U 盘是升级微码最快最方便的模式,将需要升级的微码版本下载解压缩到 U 盘根目录下的 firmware 目录内,插到 active CP 板上。

(经过测试,只有 brocade附送的 U 盘可以被交换机正确识别加载,该 U 盘芯片型号为:STEC 2.0 USB)命令行模式如果用命令行模式,登录之后使用命令 usbstorage -e 激活 U 盘;具体升级过程激活之后,使用命令 firmwaredownload -U 来从 U 盘进行微码升级使用 firmwareshow 确认升级状态,直到各 CP 板都升级完成之后,usbstorage -d 删除 U 盘,完成升级。

图形界面 WEB TOOL 升级方法使用 IE 浏览器登录交换机 GUI进入 switch admin 界面选择 firmware download进入微码升级界面选择 mount usb device 加载 U 盘加载 firmware 完成,右击相应 firmware 选择 copy 开始升级。

完成之后重新登录进行确认。

二使用命令行以及传统 FTP 模式升级准备工作将相应微码文件解压缩放入笔记本 ftp server 的根目录中备用。

使用 hub、交换机将 2 个CP 板网口都与笔记本连接。

具体升级过程登录交换机swd77 login: admin Password:检查当前 firmware 版本swd77:admin> version Kernel: 2.6.14.2Fabric OS: v6.4.2b Made on: Flash: BootProm: Tue Sep 20 17:45:13 2011 Thu Jun 7 09:11:14 2012 1.0.15备份交换机的配置信息swd77:admin> configupload Protocol (scp or ftp) [ftp]: ftp Server Name or IP Address [host]: 202.134.79.36 User Name [user]: admin File Name [config.txt]: config.txt Password: Upload complete//backup the switch configuration//ftp server ip-address //ftp server user name// specify configuration file name//ftp server user password开始下载并升级 firmwareswd77:admin> firmwaredownload//download new version firmwareYou can run firmwareDownloadStatus to get the status of this command.This command will cause the switch to reset and will require that existing telnet, secure telnet or SSH sessions be restarted. Do you want to continue [Y]: y Server Name or IP Address: 202.134.79.36 User Name: admin File Name: /v6.4.2b/release.plist Password: Firmwaredownload has started. Start to install packages...... dir ldconfig glibc bash readline terminfo termcap setup swbd12-setup which findutils bzip zlib chkconfig fileutils sed textutils procps psmisc ######################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################//ftp server ip-address //ftp server user name // file “release.plist” location //ftp server user passwordmodutils sin rcinit misc pam util-linux sh-utils popt grep rpm sysvinit man less gzip tar rsync cpio dev swbd23-bootenv wdtd wget fwdl swbd23-prom##############################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################Please avoid powering off the system during prom update. kernel swbd21-drivers pcmcia-cs sysklogd getty net-tools vixie-cron uucp bcm binutils-libs binutils ksymoops portmap inetd iptables tcpd telnet-server rsh-server rsh openssl-libs#################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################### ################################################## ################################################## ################################################## ################################################## ################################################## ################################################## ################################################## ################################################## ################################################## ##################################################openssh openssh-server rusers-server rdate logrotate ntp pciutils strace ftp ncftp sendmail iproute2 libxml2 fabos-fss fabos-setup fabos-drivers fabos-libs fabos-diag fabos-man fabos fabos-zoning fabos-fw fabos-hmon fabos-wwnhs fabos-swbd32 mmlib apache fastcgi fabos-webtools tz mtracer-tool lkcd sysstat##################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################################Write kernel image into flash. .............................. Verification SUCCEEDED Removing unneeded files, please wait ... Finished removing unneeded files.All packages have been downloaded successfully. Firmwaredownload has completed successfully. HA Rebooting ... Fabric OS (swd77)// waiting for upgrade another controllerswd77 login: admin Password:检查升级后的版本状态Slot Name Appl Primary/Secondary Versions Status-------------------------------------------------------------------------6 CP0 FOS v6.4.2b v6.4.2b 7 CP1 FOSv6.4.1b unknown STANDBY ACTIVE *大概经过 10 分钟以后,另外一个 CP 的 firmware 也升级到了目标版本Slot Name Appl Primary/Secondary Versions Status-------------------------------------------------------------------------6 CP0 FOS v6.4.2b v6.4.2b 7 CP1 FOSv6.4.2b v6.4.2b STANDBY ACTIVE *完成升级三手动单独对 CP 板轮流升级在没有 U 盘,也没有 HUB 交换机同时连接笔记本时,可以在 firmwaredownload 命令后面加参数-s 单独对链接的 CP 板进行升级微码操作;注意需要先升级 standby 的 CP 板。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

IBM POWER6 服务器 Firmware 升级与维护李光成, 软件工程师, IBM中国软件开发中心曹立, 软件工程师, IBM 中国软件开发中心余长勇 (yuchangy@), 软件工程师, IBM 中国软件开发中心赵杨 (zhaoyang@), 部门经理, IBM 中国软件开发中心王磊 (cdlwlbj@), 软件工程师, IBM 中国软件开发中心简介:服务器的 Firmware 升级和维护是系统管理员重要的日常工作之一,周期性的 Firmware 升级是提高系统稳定性,可用性和功能性的关键内容。

本文将针对 IBM POWER6 服务器 Firmware 升级和维护的方法和过程进行详细的阐述。

本文的重点将集中在 Firmware 升级和维护的技术实施层面,关于 Firmware 升级和维护的策略以及准则,可参阅文档《IBM System p Firmware / Microcode Service Strategies and Best Practices》,该文档可以从 IBM 公司的网站上下载。

本文的标签:firmware, power6, upgrade标记本文!发布日期: 2008 年 7 月 16 日访问情况 2263 次浏览建议: 0 (添加评论)平均分(共 8 个评分)IBM POWER 6® 服务器的 Firmware 升级可以通过多种途径来完成,如 HMC、IVM、运行中的 Linux/AIX 操作系统、诊断光盘、系统管理软件 ( 如 IBM Cluster System Management) 等。

本文将重点论述使用频率较高的两种方法:HMC 和 IBM Cluster System Management。

POWER 6® 服务器 Firmware 升级相关的术语和概念1.Firmware:一种嵌入到硬件设备中的程序,用于提供软件和硬件之间的接口。

在IBM POWER 6® 服务器范畴内,Firmware(固件), Microcode(微码)和 Licensed Internal Code(许可内码)是三个可以互换的概念。

2.系统 Firmware (System Firmware): 用于初始化系统配置和使系统启动和运行的 Firmware,同时系统 Firmware 也提供操作系统软件和硬件之间的接口。

3.电源子系统 Firmware (Bulk Power Subsystem Firmware):POWER 6® 服务器电源管理子系统的 Firmware,用于提供系统的电源管理和控制。

4.并发 Firmware 维护 (CFM,Concurrent Firmware Maintenance):并发Firmware 维护是IBM POWER 6® 服务器 Firmware 升级和维护的专用名词,是指在一个运行的系统上升级 Firmware 而无需重新引导系统,也不会对运行中的程序造成影响。

5.延迟升级 (Deferred Update):是指 Firmware 升级可以在并发模式下完成 , 但是升级后的某些 Firmware 功能需要在下次系统重新引导时才会起作用。

6.破坏性升级 (Disruptive Update):Firmware 升级完成后需要系统重新引导,在系统重新引导前 Firmware 升级的任何内容都不会生效。

7.T-Side/P-Side: IBM POWER 6® 服务器的服务处理器 (Service Processor)维护了两份 Firmware 的拷贝用以减少由于 Firmware 维护造成的停机频率和停机时间,这两份 Firmware 拷贝分别位于 T-Side(Temporary firmware side) 和 P-Side(Permanent Firmware Side),系统运行所使用的是位于 T-Side 的 Firmware,在 Firmware 升级和维护过程中,P-Side 一般用来存放旧的稳定的 Firmware 版本,而 T-Side 一般用来存放新的测试版本,如果证明新的 Firmware 版本运行良好,就可以将T-Side 的 Firmware 拷贝到 P-Side,这个过程叫做提交 (Commit) 或者接受 (Accept) 新的 Firmware 版本,反之,如果证明新的 Firmware 版本存在问题,就可以将 P-Side 的 Firmware 拷贝到 T-Side,这个过程叫做拒绝 (Reject) 或者移除 (Remove) 新的 Firmware 版本。

8.已激活级别 (Activated Level):运行系统正在使用的 Firmware 版本,该 Firmware 版本位于 T-Side。

9.已接受级别(Accepted Level):系统中安装的最低版本的 Firmware,该 Firmware 版本位于 P-Side.10.已安装级别 (Installed Level):系统中安装的最高版本的 Firmware,安装版本可能已经被激活或者尚未被激活。

/ibmdl/pub/software/server/firmware/01 EM320_040_031.iso 下载到该 Firmware 版本。

Firmware 文件由 15 个字符组成,由两个下划线将文件名分隔为三个字段,我们以通用格式 PPNNSSS_FFF_DDD 为例:1.PP:子系统识别符 (Package Identifier),用以标识此 Firmware 所适用的子系统。

系统 Firmware 的子系统识别符为 "01", 电源子系统Firmware 的子系统识别符为 "02".2.NN:平台识别符 (Platform Identifier), 用以标识此 Firmware 所适用的服务器类型。

平台识别符是由 IBM 公司统一分配的。

下表列出了目前所有的POWER 6® 服务器平台识别符:类型描述服务器型号平台识别符IBM POWER 6® 570 9117 EMIBM POWER 6® 520/550 8202 ELIBM POWER 6® 575 9125 ESIBM POWER 6® 595 9119 EHBPA for POWER 6® 575 9A00 EPBPA for POWER 6® 595 9A01 EB表1 POWER 6® 服务器平台识别符1.SSS:发布级别标识符 (Release Level Indicator),每一个新的Firmware 发布级别都会相应的包含新的功能和新的服务器类型支持,IBM 的 Firmware 发布策略为每年内一般不会超过两个新的发布级别。

发布级别的升级都将是破坏性升级。

2.FFF:修订级别 (Service Pack Level),一个发布级别之下的修订版本级别。

一般情况下,一个修订级别只包含一些问题的修复而不会包含新的动能或者新的服务器类型支持。

3.DDD:上一个破坏性级别 (The last disruptive Level),从“DDD”所标识的修订级别之前的修订级别升级到该修订都将是破坏性升级。

升级方法 准备工作HMC 1. 兼容的 HMC 版本2. P 服务器和 HMC 之间的正确连接3. Firmware 映像,包括 Firmware 的 RPM和相应的 xml 文件。

CSM1. 配置 CSM 对服务器和 HMC 的管理功能2. Firmware 映像,包括 Firmware 的 RPM和相应的 xml 文件1. 登录 HMCPOWER 6® HMC 支持 web 方式登录,可以用任意 web 浏览器如 Internet Explorer 或者 Mozilla Firefox 进行登录。

登录方式:https://<HMC ip address or hostname>2. 检查服务器的当前 Firmware 版本信息在 HMC 控制界面左侧选中“更新”,进入 Firmware 升级界面,选中目标服务器后,点击服务器名称右上角的 弹出菜单的“查看系统信息”或者屏幕下方的“查看系统信息”,将会显示服务器目前的 Firmware 版本信息,如下图所示:图 1通过 EC 号中的平台标识符可以得知,该机器类型为POWER 6® IH 同时配置了POWER 6® BPA,系统 Firmware 和电源子系统 Firmware 的发布版本为 330,已安装级别,已激活级别和已接受级别均为 14.3.确定升级类型根据现有 Firmware 版本和目标 Firmware 版本之间的关系,Firmware 升级可以分为两种类型:更改当前发行版的许可内码(即修订版本升级)和将许可内码升级到新的发行版(即发布版本升级)。

修订版本升级和发布版本升级在操作上基本类似,只是修订版本升级有可能是并发升级而发布版本升级一定是破坏性升级。

以下的论述将以修订版本升级为例因为IBM POWER 6® 575 到目前为止仅有一个发布版本 330。

4.确定 Firmware 存储位置HMC 支持使用多种 Firmware 存储位置来进行 Firmware 升级,包括 IBM 服务 Web 站点、IBM 支持系统、DVD 驱动器、FTP 站点和硬盘驱动器。

如果 HMC 有 Internet 连接,可以:1.使用 IBM 服务 Web 站点去获取最新的 Firmware 版本2.或者使用 IBM 支持系统去获取所有的可以使用的 Firmware 版本。

如果 HMC 没有 Internet 连接,则可以:3.建立本地的 FTP 服务器然后使用 FTP 站点作为 Firmware 存储位置4.或者将 Firmware 映像刻录到光盘中然后使用 DVD 驱动器作为Firmware 存储位置5.或者使用 HMC 高级功能中的 retrieve 功能将 Firmware 映像先下载到 HMC 的硬盘驱动器 , 然后使用硬盘驱动器作为 Firmware存储位置(缺省目录 /opt/ccfw/data)6.如果以前曾经进行过成功的 Firmware 升级,HMC 将会在硬盘驱动器上保存一份 Firmware 的拷贝,则可以使用硬盘驱动器作为Firmware 存储位置5.升级 Firmware:1.选中目标服务器后,点击服务器名称右上角的弹出菜单的“更改当前发行版的许可内码”或者屏幕下方的“更改当前发行版的许可内码”,将会弹出更改许可内码窗口。