TABLE 6. LOWEST ON-WING VISCOSITY VALUES FOR DE/ANTI-ICING FLUIDS

(See Page 3 for Table 6 Notes)

(See Page 3 for Table 6 Notes)

(Table 6 Notes)

NOTES

1 Significance of this Table: The viscosity values in this table are those of the fluids provided by the manufacturers for holdover

time testing. For the holdover time guidelines to be valid, the viscosity of the fluid on the wing shall not be lower than that listed in this table. The user should periodically ensure that the viscosity value of a fluid sample taken from the wing surface is not lower than that listed.

2 The Aerospace Information Report (AIR) 9968 viscosity method should only be used for field verification and auditing

purposes; when in doubt as to which method is appropriate, use the manufacturer method. Viscosity measurement methods are indicated as letters (in parentheses) beside each viscosity value. Details of each measurement method are shown in the table below. The exact measurement method (spindle, container, fluid volume, temperature, speed, duration) must be used to compare the viscosity of a sample to a viscosity given in this table.

3 Measurements using the AIR 9968 method do not provide stable, reliable results. Use the manufacturer method to evaluate

the viscosity of this fluid.

Method Brookfield

Spindle

Container

Fluid

Volume

Temp. Speed Duration

a LV1

(with guard leg)

600 mL low form (Griffin) beaker 575 mL* 20°C 0.3 rpm 10 minutes 0 seconds

b LV1

(with guard leg)

600 mL low form (Griffin) beaker 575 mL* 20°C 0.3 rpm 33 minutes 20 seconds

c LV2-disc

(with guard leg)

600 mL low form (Griffin) beaker 425 mL* 20°C 0.3 rpm 10 minutes 0 seconds

d LV2-disc

(with guard leg)

250 mL tall form (Berzelius) beaker 200 mL* 20°C 0.3 rpm 10 minutes 0 seconds

dd LV2-disc

(with guard leg)

200 mL tall form (Berzelius) beaker 155 mL* 20°C 0.3 rpm 10 minutes 0 seconds

e LV2-disc

(with guard leg)

150 mL tall form (Berzelius) beaker 135 mL* 20°C 0.3 rpm 10 minutes 0 seconds

f SC4-34/13R small sample adapter 10 mL 20°C 0.3 rpm 10 minutes 0 seconds

g SC4-34/13R small sample adapter 10 mL 20°C 0.3 rpm 15 minutes 0 seconds

h SC4-34/13R small sample adapter 10 mL 20°C 0.3 rpm 30 minutes 0 seconds

i SC4-31/13R small sample adapter 10 mL 20°C 0.3 rpm 10 minutes 0 seconds j SC4-31/13R small sample adapter 10 mL 0°C 0.3 rpm 10 minutes 0 seconds k SC4-31/13R small sample adapter 9 mL 20°C 0.3 rpm 10 minutes 0 seconds l SC4-31/13R small sample adapter 9 mL 0°C 0.3 rpm 10 minutes 0 seconds m LV0 UL adapter 16 mL 20°C 0.3 rpm 10 minutes 0 seconds n LV1 big sample adapter 50 mL 20°C 0.3 rpm 10 minutes 0 seconds o LV1 big sample adapter 55 mL 20°C 0.3 rpm 10 minutes 0 seconds p LV2-disc big sample adapter 60 mL 20°C 0.3 rpm 10 minutes 0 seconds *If necessary, adjust fluid volume to ensure fluid is level with notch on the spindle shaft