1 概述
综合录井仪是石油天然气钻井现场使用的一种大型电子仪器。其功能是记录钻井数据,监测 钻井过程,指导生产、提供安全保障。
随着油气勘探开发难度越来越大,钻井周期越来越短,安全要求越来越高,如何更加有效地 发挥录井技术在石油地质和钻井工程两方面的优势,不仅是录井工程自身发展的要求,而且也是 油气勘探开发行业的要求。ACE 智能录井系统(SLZ-3 型)是中国电子科技集团公司第二十二研 究所自行研究开发的新一代录井产品。
能单位指示灯的指示意义如下: W: 有功功率(W,kW)
左侧三个窗口 为电压窗口
右侧三个窗口 “设置”键
为电流窗口
“启动”键
PF: 功率因数 Hz: 频率(Hz)
“停止”键
W·h:有功电能(kW·h/MW·h) TIME:电能累计时间 AUTO:自动循环(每 2 秒种变换一次)
“复位”键 “锁定”键
3.2 吊运及安装
1) 吊运时应采用合格的钢丝绳和卸扣,保证起吊的安全。 2) 仪器房的起吊和安放要平稳,不能对仪器房进行较重的撞击,防止内部仪器遭受不必要的损坏。 3) 仪器房在现场安放时,场地要平整,大门朝井架方向,安全窗外要有足够的逃生空间。 4) 在仪器房与传感器安装现场之间须架设一根钢丝绳,所有电缆应用挂钩悬挂在钢丝绳上。
3
智能录井系统--使用手册介绍
位开始,如此循环:
4.3.1.2 操作方法
按“设置”键进入参数设定状态后,只有第一、第二窗口显示。其中第一窗口显示提示符, 第二窗口为对应参数值。可以修改。 1) 输入密码
按下“设置”键进入“密码输入”,提示符显示:CODE 输入密码“1234”再按“设置”键确认,转到下一项。必须正确输入密码,否则下面设置的 参数将不能保存。 2) 接线方式设置 提示符显示:LINE 3 相 3 线制:3P3L(3 相 3 线制两元件法) 3 相 4 线制:3P4L 3V3A:3U3A(3 相 3 线制三元件法) 选择正确的制式。再按“设置”键确认存储,转到下一项。制式与接线方式有直接关系,必 须准确无误。否则功率电量等参数测量不准确。出厂时设为 3 相 4 线制。 3) 电压倍率 PT 设置 提示符显示:UUUU XXX.X 改变 PT 值。设置完毕按“设置”确认,转到下一项。出厂时设为 1。 4) 电流倍率 CT 设置 提示符显示:AAAA XXX.X 改变 CT 值。设置完毕按“设置”确认,转到下一项。出厂时设为 1。 5) 电压报警上限设置 提示符号显示:U ̄ ̄ ̄ XXX.X 改变电压报警上限值。设置完毕按“设置”转到下一项。出厂时设为 250V。 6) 电压报警下限设置: 提示符号显示:U___ XXX.X 改变电压报警下限值。设置完毕按“设置”转到下一项。出厂时设为 198V。 7) 电流报警上限设置: 提示符号显示:A ̄ ̄ ̄ XXX.X 改变电流报警上限值。设置完毕按“设置”转到下一项。出厂时设为 15A。 8) 电流报警下限设置 提示符号显示:A___ XXX.X 改变电流报警下限值。设置完毕按“设置”转到下一项。出厂时设为 0.001A。 9) 电能累计限定时间设置 提示符显示:E─E XX.XX 改变电能累计限定时间值。格式:小时.分钟:最大 99 小时 59 分钟。设置完毕按“设置”确 认,转到下一项。出厂时设为 0,此时电能累计不再受设定的时间限制。 10) 保存设置 提示符显示:SAVE N— —Y 通过“>”键来改变闪烁位,当 N 闪烁时按“设置”键退出设置状态,但不保存改动过的参 数。当 Y 闪烁时按“设置”键退出设置状态并保存改动过的参数。如果密码不对或没改动过参数, 那么不会出现此提示。在设置状态下,如果在 15 秒种内无按键操作,测量仪会自动退出设置状态, 4
4 配电系统
配电系统由配电盘、隔离变压器、UPS、总电 源线等组成。
仪器房外部电源进线为三相四线制,可由市电 电网或井场发电机供电。仪器房内设有配电箱,除 脱气器等少数设备直接使用三相电源外,大部分设 备均由配电箱分配为单相供电。配电系统示意图如 图 2 所示。
在使用中,如果需要改动配电系统,必须由具 有专业资格的人员进行配线连接。
如此循环;闪烁位表示次位可修改。
“∧”键:改变参数值的闪烁位的数值,每按一次,数值加 1,加到 9 后再从 0 开始,如此循环。
“∨”键:改变参数值的闪烁位的数值,每按一次,数值减 1,减到 0 后再从 9 开始,如此循环。
“· ”键:改变参数值小数点的位置,每按一次小数点向左移动一位,移到最后时,再从第一
数据锁定,此时锁定的指示灯电亮,再按一下指示灯灭,解除锁定。
“设置”、“>”、“∧”、“∨”、“· ”键,用来设定或查看仪表的工作参数。
“设置”键:选择要修改或查看的参数。“>”、“∧”、“∨”、“· ”键,用来修改或查
看相应参数的数值。具体功能如下:
“>”键:改变参数值的闪烁位,每按一次闪烁位向右移动一位,移到最后再从第一位开始,
3 仪器房
3.1 仪器房结构
1) ACE 智能录井系统仪器房外壳采用集装箱形式,外形尺寸标配为 8.4×2.4×2.8m。 2) 墙壁、顶部用 2mm 波纹钢板,地板用 6mm 平钢板。 3) 仪器房大门、逃生窗、观察窗达到 A60 防火等级。 4) 内部墙板、家具采用环保型产品。 5) 工作台面及地板采用中密度板,表面贴防火板。 6) 显示器采用液晶屏并安装于墙板上。 7) 工作环境安全、宽敞、舒适。 8) 小隔间设计合理实用,扩大了储物空间。 9) ACE 智能录井系统还可选配我所生产的 SLZ-2AF 型防爆仪器房。
入口区接线箱
出口区接线箱
脱 气 器
气体分析单元
应用计算机
1#监视屏
监控计算机
视频重复器 打印服务器
2#监视屏
采集计算机
1#打印机
PC104
2#打印机
配电系统
智能快速气测仪 计算机系统
数据服务器 备份服务器
隔离变压器
UPS
配电盘
3#打印机
4#打印机
机柜 计算机系统
辅助设备
图 1:系统框图
1
智能录井系统--使用手册介绍
3.1 仪器房结构 ··························································································2 3.2 吊运及安装 ··························································································2 4 配电系统 ·································································································2 4.1 接地 ··································································································2 4.2 接电 ··································································································2 4.3 配电盘 ·······························································································2 4.4 隔离变压器及 UPS ·················································································5 5 主机柜 ····································································································5 6 计算机系统 ·····························································································12 7 传感器及 CAN 采集系统 ·············································································13 8 主要技术特点及性能指标 ············································································13 8.1 技术特点 ···························································································13 8.2 主要技术指标 ······················································································13
分相 开关
脱气器 保护器
门锁
后,测量的为仪器总的参数。
4.Βιβλιοθήκη Baidu.1.1 前面板
图 3:配电盘
8967B 综合电量监测仪的前面板参见图 4 所示。仪器前面板由显示部分,按键部分,状态指 示部分组成。显示窗口部分有七个显示窗口。
1) 六个四位数码管窗口分别显示的是:U1、U2、U3、I1、I2、I3。
2) 第七个窗口为多功能窗口,由 6 位数码管组成。显示的具体内容有右侧指示灯来指示。各功
配电盘安装于仪器房内,包括综合电量
监测仪、电源总开关、分相开关、脱气器保 护器等。
4.3.1 综合电量监测仪
综合电量监测仪是一种利用单片机技 术,直接对三相交流信号采样、分析,处理
电源总 开关
综合电量 监测仪
脱气器 控制开关
的智能型综合仪表。具有功能齐全、可靠性 高、抗干扰能力强等特点。可测量三相电压、 三相电流、三相功率、总功率、功率因数、 频率、累计电能等参数及具有断相、超限等 报警功能。综合电量监测仪接于电源总开关
图 2:配电系统示意图
4.2 接电
总电源插座安装于小隔间内。在接井场电源前应拔掉总电源插头,连接 380V(三相四线制) 电源后用万用表测量电源插头的火线、零线正确后,再接上总电源插头。如图 3 所示。
总电源插座盒内,安装有避雷器,应将避雷地线可靠接地。
4.3 配电盘
2
智能录井系统--使用手册介绍
3) 面板按键功能 “选择”键:用来改变第七个窗
口的显示参数,每按动一次,相应功
第七窗口为多功 能窗口,有选择 键控制显示
显示指示灯与 第七窗口显示 内容相对应
“选择”键 可分别显示 第七窗口各 个功能
能指示灯亮,显示对应的参数。可选 择:有功总功率、功率因数、频率。
图 4:综合电量监测仪示意图
“锁定”键:用来锁定当前的显示值,当被测负载变化比较快时不易读数,可以按锁定键将
4.1 接地
仪器房就位后,应接上安全地线。接地装置在 仪器房正面右下侧。接地线应与接地装置连接可 靠,地线桩应埋入地下,并使周围土层保持湿润。
总电源插座 总电源开关 综合电量测试仪 综合电量测试仪
隔离变压器
脱气器电源开关
空调1 空调2 照明 空压机 隔间备用 备用
UPS1 UPS2
电动机保护器 脱气器
2 系统框图
ACE 智能录井系统(SLZ-3 型)由仪器房、传感器、CAN 总线采集系统、智能快速色谱仪、 计算机系统和配电系统组成。除传感器、接线箱、脱气器等设备外,其他部分工作时安装在拖橇 内。系统框图如图 1 所示。
仪器房
交换机
CAN总线系统
出口区 传感器组
入口区 传感器组
井台区 传感器组
井台区接线箱 CAN总线采集单元
智能录井系统--使用手册介绍
目次
1 概述 ·······································································································1 2 系统框图 ·································································································1 3 仪器房 ····································································································2