3030SQ 3031SQ /3030SQ-SSPTo properly operate and maintain your Dixon Bayco 3030 / 3031 swing check valve the following instructions are provided. Please read with care as improper handling or maintenance may cause a hazardous condition.Do not modify your Dixon Bayco swing check valve for any reason. It can result in a hazardous condition due to operating difficulties or operation malfunction. Disassembly or tampering will void the product warranty.Immediately remove from service any swing check valve that is not performing satisfactorily.InstallationDixon Bayco swing check valves are properly adjusted and ready to use upon leaving the factory. Swing check valves are designed to be tough and to provide long service with reasonable care and handling.1. Ensure arrow is pointing downstream of product flow when installing.2. Apply appropriate gasket for square-flanged (3030SQ / 3031SQ) and round-flanged (3030RD / 3031RD) models.TemperatureDixon Bayco 3030 series swing check valves with molded flappers are not recommended for direct blower mounted service. For direct blower mounted service use 3031 (or 3030-SSP) series swing checks valves.Inspection and MaintenanceSwing check valves can fail to operate if not properly maintained. Frequently check for damage, loose or missing parts.Swing check valves assure one-way airflow during the off loading or unloading of product. Swing check valves prevent back flow of product into the blower or piping system. These safety devices consist of a simple flapper valve that swings clear of the air stream during the normal off-loading operation, but will immediately close when there is an air stoppage or airline pressure reversal. Once installed, the valves are often ignored. However, they are a crucial element in the proper operation of the dry bulk air transfer systems and the protection of expensive blower equipment.Swing check valve simplicity and historical durability are probably the reason for inspection complacency. But, swing checks are subject to temperature extremes and vibration fatigue that can affect wear and longevity. Wear in particular can result as flapper and hinge mechanisms vibrate constantly during road travel. Also remember that blowers raise intake air temperatures by as much as 200°F. That means if the outside is 100°F, then airline plumbing (including swing checks) can reach 300°F. High temperatures combined with pulsation stress from the blower and road travel vibration creates a hostile working environment that warrants performance inspections on a regular basis.There are two basic ways to inspect swing checks: (a) visual/manual, on the tanker and (b) removed from tanker, on a test stand.Do not attempt to inspect the valve while in use; this may result in severe damage or injury.How to InspectThe complete valve assembly may be removed and replaced without removing the valve body from the system. Please note that the shafts and springs are designed for left and right orientation, ensure that these components are located correctly. The colored spring should be used in conjunction with the right hand threaded shaft.1. Remove the inspection cap/cover and hand operate valve to ensure springs are in good working order and flapper seats properly without restriction.2. Whilst pulling the flapper forwards, pull upwards on the valve yoke to withdraw the complete flapper assembly (take care to ensure that springs are secure during valve withdrawal).3. Inspect valve seat and valve for wear or gaps.4. Inspect for product stuck in flapper assembly or valve seat causing the flapper to hang open.5. If springs are replaced, please ensure that, after replacement, the valve assembly is free to swing to the fully open position (90°) without excessive resistance. If excessive resistance is felt:- Ensure that the springs are fully pressed onto the shaft.- Reduce spring pre-load by moving torsion spring legs toalternative pre-load stop. The correct amount of pre-loadallows the valve to be freely opened to 90°.Should problems be encountered replace valve immediately.Your Dixon Bayco 3030 / 3031 swing check valve is designed for minimal flow restriction and low pressure drop during operation. The valve return springs are designed to provide sufficient pre-load to return the valve to the closed position with only limited pre-load. Excessive pre-loading of the return springs may lead to premature failure.Inspection FrequencySwing check valves should be routinely inspected as part of a preventative maintenance schedule for dry bulk tankers. The units should be given, at a minimum, a visual/manual inspection every 2-3 months.Do not use anything other than genuine Dixon Bayco parts in your Dixon Bayco swing check valve. Repair kits are available for all replaceable parts (refer to parts breakdown for details). Use of non-approved or modified parts can result in a hazardous condition due to operating difficulties or operation malfunction. Modification or tampering will void the product warranty.Dixon Bayco WarrantyFor complete warranty information, please refer to the latest Dixoncatalog.。

温度控制器的使用说明书

温度控制器的使用说明书

温度控制器的使用说明书一、产品简介温度控制器是一种用于调节温度的装置。

它通过感知环境温度的变化,并根据设定参数来控制加热或制冷设备的工作状态,以达到温度控制的目的。

本使用说明书旨在帮助用户正确操作和使用温度控制器,提供详细的使用指南和注意事项。

二、产品外观1. 温度控制器的外观设计简洁美观,采用灰色塑料外壳,具有良好的手感和耐用性。

2. 正面面板采用液晶显示屏,可清晰显示当前温度、设定温度以及其他相关信息。

3. 控制按钮位于正面面板下方,用户可通过按钮进行参数设置和操作。

三、使用方法1. 安装a) 在使用温度控制器之前,请先确保断电状态,并按照产品手册提供的安装步骤进行正确安装。

b) 将温度控制器固定在合适的位置,并确保其与被控制的设备连接牢固、接线正确。

2. 参数设置a) 打开温度控制器电源,系统将自动启动并显示当前温度。

b) 按下设置按钮进入参数设置模式,并使用上下按钮选择要设置的参数。

c) 通过加减按钮调节参数数值,确认后按下确认按钮保存设置并退出设置模式。

d) 确保设定的温度范围和控制模式与实际需求相匹配。

3. 运行控制a) 在参数设置完成后,温度控制器将自动开始工作。

在正常工作状态下,控制器将根据设定温度和当前温度进行判断,并控制相关设备的启停。

b) 温度控制器具备过温保护功能,当探测到温度超过设定范围时,控制器将自动切断电源,避免设备过热。

四、注意事项1. 使用前请阅读并确保理解本使用说明书的所有内容,遵循说明书提供的正确操作方法和注意事项。

2. 请勿将温度控制器暴露在恶劣的环境条件下,如强烈阳光直射、高温、潮湿或腐蚀性气体影响的场所等。

3. 温度控制器仅适用于指定的电压和电流范围,请勿使用超过规定的电源供应。

4. 如需更换温度探头,请关闭电源并按照说明书提供的步骤进行更换,以免发生触电或其他意外伤害。

5. 若长时间不使用温度控制器,请将其断电并保存在干燥通风的地方,以延长使用寿命。

T901-1-使用说明书DN150

T901-1-使用说明书DN150

塔河油田9区奥陶系凝析气藏滚动产能建设工程T901-1阀组站放空火炬系统点火操作说明书二〇一四年十月目录一、系统说明 (2)二、工作原理 (2)三、操作规程 (2)四、维护及保养 (3)附图:1.远程点火控制柜面板图2.接线端子图3.通讯接口地址表一、系统说明塔河油田9区奥陶系凝析气藏滚动产能建设工程T901阀组站放空火炬点火控制系统主要由远程点火控制柜、高能点火器、电磁阀、流量开关、热电偶等组成。

二、工作原理当火炬需要放空时,控制系统收到放空管线上的流量信号,自动打开燃气电磁阀、同时启动高能点火器点火,火炬头顶部的电咀打火,点燃引火筒,引火筒的火焰再引燃放空气体,实现火炬的自动点火功能。

上述点火功能也可手动分步实现。

三、操作规程1. 系统操作前首先检查燃气管线是否畅通,保证点火用天然气压力在0.2~0.4Mpa,同时检查并排掉管线中的冷凝液。

电磁阀、过滤器前后的截止阀常开,旁路阀处于常闭状态。

如需要引燃长明灯,打开长明灯两路手阀即可。

2. 工作过程“自动”状态下实现无人值守自动点火;“手动”状态下可在站控室内手动点火。

在站控制室点火控制柜面板上(详见附图)设自动/手动点火切换开关。

点火操作前,将电源转换开关切换至“1”位置,电源指示灯亮。

然后按下“灯测试”按钮,面板上所有指示灯亮,松开按钮后,所有指示灯熄灭,证明指示灯工作正常;此时可选择点火模式进行点火操作:(1) 手动点火将点火模式选择转换开关切换至“手动”位,打开电磁阀按钮(预留开关)、“电磁阀指示”(C-1002指示)亮,此时燃气电磁阀已打开,然后按下“C-1001点火或C-1002点火”按钮,进行点火(时间每次约5秒),引火筒引燃后,其火焰再引燃主火炬,温控仪表显示其温度值(测温值会有变化,上升),此时可以停止点火,关闭燃气电磁阀,点火结束。

(2) 自动点火将点火模式选择转换开关切换至“自动”位,此时点火程序由PLC完成,当流量开关检测到有放空信号时“放空指示”灯会亮,PLC自动打开燃气管线上的电磁阀、然后启动点火器进行点火,系统将自动尝试三次点火操作,直到点燃引火筒,随即引燃主火炬。

gwktecocs90t模温机中文说明书

gwktecocs90t模温机中文说明书

Teco cs 90t 手册目录1一般规则错误!未定义书签。

介绍错误!未定义书签。

2符合声明错误!未定义书签。

3铭牌错误!未定义书签。

4经营者的职责错误!未定义书签。

安全意识的操作错误!未定义书签。

人员的资格错误!未定义书签。

用户错误!未定义书签。

5安全信息错误!未定义书签。

一般错误!未定义书签。

6安全信息错误!未定义书签。

软管的使用错误!未定义书签。

蒸汽加热设备(具体设备)错误!未定义书签。

爆炸区域(特定于设备)错误!未定义书签。

火灾和爆炸的危险!(设备特定)错误!未定义书签。

7警告信息错误!未定义书签。

8使用符号错误!未定义书签。

9功能说明错误!未定义书签。

正确使用错误!未定义书签。

避免可预测的不正确使用错误!未定义书签。

单元的功能错误!未定义书签。

10运输和安装错误!未定义书签。

一般错误!未定义书签。

运输错误!未定义书签。

设置条件错误!未定义书签。

安装错误!未定义书签。

对抗腐蚀和霜冻的措施错误!未定义书签。

存储错误!未定义书签。

11连接系统错误!未定义书签。

一般错误!未定义书签。

操作员必须提供以下连接:错误!未定义书签。

进行以下连接:错误!未定义书签。

冷却水连接错误!未定义书签。

电连接错误!未定义书签。

12填充和排出单元错误!未定义书签。

一般错误!未定义书签。

填充错误!未定义书签。

调节温度设定值错误!未定义书签。

排空wi / wd单元/机器错误!未定义书签。

补充错误!未定义书签。

泵错误!未定义书签。

13加热并启动装置错误!未定义书签。

加热错误!未定义书签。

14启动错误!未定义书签。

15手动触摸屏错误!未定义书签。

16按钮和符号说明错误!未定义书签。

17目标值菜单错误!未定义书签。

设定点温度错误!未定义书签。

设定值温度错误!未定义书签。

最大限温设定点错误!未定义书签。

冷却设定点错误!未定义书签。

温度上限报警错误!未定义书签。

温度下限报警错误!未定义书签。

流量上限报警错误!未定义书签。

流量下限报警错误!未定义书签。

温度控制器使用说明书

温度控制器使用说明书

温度控制器使⽤说明书XMT-6000智能型数字显⽰温度控制器使⽤说明书此产品使⽤前,请仔细阅读说明书,以便正确使⽤,并妥善保存,以便随时参考。

!警告接线警告—如果仪表失效或发⽣错误,可能引起系统故障,安装外部保护电路以防⽌此类事故。

—为防⽌仪表损坏或失效,选⽤适当的保险丝保护电源线及输⼊/输出线以防电流冲击。

仪表供电—为防⽌触电或仪表失效,所有接线⼯作完成后⽅能接通电源。

禁⽌在易燃⽓体附近使⽤—为防⽕、防爆或仪表损坏,禁⽌在易燃、易爆⽓体,排放蒸汽的场所使⽤。

严禁触及仪表内部—为防⽌触电或燃烧,严禁触及仪表内部。

发⽣质量问题请与上海亚泰仪表⼚营销部联系,只有“亚泰”服务⼯程师可以检查内部线路或更换部件,仪表内部有⾼电压,⾼温部件,⾮常危险!严禁改动仪表—为防⽌事故或仪表失效,严禁改动仪表。

保养—为防⽌触电,仪表报废或失效,只有“亚泰”服务⼯程师可以更换部件。

—为保证仪表长期安全使⽤,应定期保养。

仪表内部某些部件可能随使⽤时间的延长⽽损坏。

操作注意断电后⽅可清洗仪表。

清除显⽰器上污渍请⽤软布或棉纸。

显⽰器易被划伤,禁⽌⽤硬物擦拭或触及。

禁⽌⽤螺丝⼑或书写笔等硬物体操作⾯板按键,否则会损坏或划伤按键。

1.产品确认本产品适⽤于注塑、挤出、吹瓶、⾷品、包装、印刷等机械设备;恒温⼲澡、⾦属热处理等设备的温度控制。

本产品的PID参数可以⾃动整定,是⼀种智能化的仪表,使⽤⼗分⽅便,是指针式电⼦调节器、模拟式数显温控仪的最佳更新换代产品。

本产品符合Q/SQG01-1999智能型数字显⽰调节仪标准的要求。

请参照下列代码表确认送达产品是否和您选定的型号完全⼀致。

XMT□-□□□□□□□—□①②③④⑤⑥⑦⑧⑨①⾯板尺⼨mm⑤输⼊类型D:96×96 1:热电偶信号E:72×72 2:热电阻信号F:96×48(竖式);F(H):48×96(横式) ⑥输出类型G:48×48 空:继电器(最⼤1A)②显⽰⽅式V:逻辑电平输出⽤于SSR6:双排显⽰(经济型)B: 继电器(最⼤10A)③控制类型G: 可控硅输出(直接带300W以下负载)0:位式动作⑦分度号3:时间⽐例动作⑧量程下限4:两位PID动作及⾃动整定⑨量程上限7:单相过零脉冲PID及⾃动整定<附件>④限位报警安装⽀架2套,说明书⼀份0:⽆报警1:上限报警(XMTD、XMTF过零脉冲输出、逻辑电平输出,以及XMTG的各型号不能带上限报警)2.安装(5)推紧安装⽀架,使仪表与盘⾯结合牢固,收紧螺钉。

温控仪使用说明书

温控仪使用说明书

温控仪使用说明书:设备所采用的温控仪型号为XMT603 外形尺寸:48*96*112mm电源电压:AC220V (±15%,50Hz );功耗:3~4W ; 环境温度:0~50℃;相对湿度:≤85%无腐蚀性气体场合; 输入信号:PT100分度号热电阻;显示范围:-200.0℃~600.0℃; 分辨率:0.1℃;精度:0.2% . 按键定义: 功能键 :用于选择窗口页面,不同页面用J1、J2、COM 指示灯区别; 位选键 :循环选定页码内的数码管,选定的数码管呈闪烁状态; 增加键:改变闪烁位数码管的数值(第一位从0~9、“-”、-1循环,后三位从0~9循环)。

操作方法:用键选择页面窗口,用键和键改变页面内数码管的数值。

操作步骤:分为PP89、PP36、PP01三项内容,按下面流程图操作:1 置出PP89进入A1页(此项已设定A1:0008,B1:0000),可设定符合要求的输入信号和变送输出信号:PP01PP89PP36 XXXX 设定输入信号编号、变送输出编号 设定量程高低限,变送高地限、小数点 设定J1、J2继电器的吸合值、释放值― ― ― ― 测量显示结束标志操作流程图2置出PP36进入A2页(此项已设定A2:0000,B2:0000,C2:0000,D2:0000 ,E2:0001),确定输入信号对应的显示范围和变送输出范围:测量显示结束标志设定显示范围、变送输出、小数点要求如下:1)通常,A2页,B2页必须为0000,特殊修要修正时,A2页用于量程平移修正,适当填入正数或负数,修正后显示值=修正前显示值+A2页的值。

B2页用于量程满值修正,适当填入正数或负数,可使量程变大或变小,0值不变。

2)C2页填入变送低限值,D2页填入变送高限值。

3)E2页用于确定小数点位置,0001;0002;0003对应显示XXX.X、XX.XX、X.XXX;0004以上无小数点显示。

3 置出PP01进入A3页(此项由用户根据需要自行设定),通过设定继电器吸合、释放值,实现上下限、上上限、下下限报警或二位式、三位式控制,满足现场使用要求。

3寸流体控制阀门说明书

3寸流体控制阀门说明书

Product Features50 psi bubble tight shut-off, Long stem design allows for 2” insulation, Valveface-to-face dimensions comply with API 609 & MSS-SP-67, Completelyassembled and tested, ready for installation, Tees comply with ASME/ANSIB16.1 Class 125 flangesApplicationThese valves are designed to meet the needs of HVAC and commercialapplications requiring bubble tight shut-off for liquids. Typical applicationsinclude chiller insolation, cooling tower isolation, change-over systems, largeair handler coil control, bypass and process control applications. The largeCv values provide for an economical control valve solution for larger flowapplications. Designed for use in Victaulic piping systems.Jobsite NoteValves should be stored in a weather protected area prior to construction.Complete installation recommendations can be found in Belimo’s Installationand Maintenance Instructions for F6/F7… Butterfly Valves.Application NotesThese valves are designed to meet the needs of HVAC and commercialapplications requiring 0% leakage for liquids. Typical applications include chillerisolation, cooling tower isolation, change-over systems, large air handler coilcontrol, bypass and process control applications. The large Cv values providefor an economical control valve solution for larger flow applications. Designedfor use in ANSI flanged piping systems.F780HDU, 3-Way Butterfly ValveResilient Seat, 304 Stainless Steel DiscDatecreated,7/1/216-Subjecttochange.©BelimoAircontrols(USA),Inc.F780HDU, 3-Way Butterfly Valve Resilient Seat, 304 Stainless Steel DiscDatecreated,7/1/216-Subjecttochange.©BelimoAircontrols(USA),Inc.†Rated Impulse Voltage 800V, Type action 1, Control Pollution Degree 3.GMX24-MFT-X1Modulating, Non-Spring Return, 24 V, Multi-Function Technology®D a t e c r e a t e d , 07/10/2016 - S u b j e c t t o c h a n g e . © B e l i m o A i r c o n t r o l s (U S A ), I n c .AActuators with appliance cables are numbered.Provide overload protection and disconnect as required.Actuators may also be powered by 24 VDC.Only connect common to negative (-) leg of control circuits.A 500 Ω resistor (ZG-R01) converts the 4 to 20 mA control signal to 2to 10 VDC.Control signal may be pulsed from either the Hot (Source) or Common(Sink) 24 VAC line.For triac sink the Common connection from the actuator must be connected to the Hot connection of the controller. Position feedback cannot be used with a triac sink controller; the actuator internalcommon reference is not compatible.IN4004 or IN4007 diode. (IN4007 supplied, Belimo part number 40155).46Actuators may be controlled in parallel. Current draw and input impedance must be observed.47Master-Slave wiring required for piggy-back applications. Feedbackfrom Master to conrol input(s) of Slave(s).Meets cULus requirements without the need of an electrical ground connection.!WARNING! LIVE ELECTRICAL COMPONENTS!During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury.GMX24-MFT-X1Modulating, Non-Spring Return, 24 V, Multi-Function Technology®D a t e c r e a t e d , 07/10/2016 - S u b j e c t t o c h a n g e . © B e l i m o A i r c o n t r o l s (U S A ), I n c .GMX24-MFT-X1Modulating, Non-Spring Return, 24 V, Multi-Function Technology®D a t e c r e a t e d , 07/10/2016 - S u b j e c t t o c h a n g e . © B e l i m o A i r c o n t r o l s (U S A ), I n c .。

温度控制器的说明书

温度控制器的说明书

温度控制器的说明书一、产品介绍温度控制器是一种用于控制温度变化的设备,通常应用于各类加热或冷却系统中,以确保温度的稳定和准确性。

本说明书将详细介绍温度控制器的使用方法、技术规格以及安全注意事项。

二、技术规格1. 输入电压:AC 220V2. 控制类型:PID控制3. 温度范围:-50℃至+150℃4. 温度精度:±1℃5. 输出类型:继电器输出6. 外观尺寸:120mm×80mm×40mm三、使用方法1. 连接电源:将温度控制器的电源线连接到AC 220V电源上。

2. 连接传感器:根据需要,将温度传感器连接到温度控制器的探头接口上。

3. 设置温度目标值:使用温度控制器面板上的按钮和显示屏,设置所需的温度目标值。

4. 参数调整:按照需要,调整PID控制参数以实现更准确的温度控制。

5. 启动控制器:按下温度控制器面板上的启停按钮,控制器将开始工作并调节系统温度。

6. 监控温度:使用控制器面板上的显示屏,实时监控当前温度以及目标温度。

四、安全注意事项1. 在安装和操作控制器之前,请确保断开电源以防止电击事故。

2. 请根据产品规格正确选择电源电压,使用不符合规定电压的电源会导致设备损坏。

3. 定期检查控制器、传感器和电缆的连接是否牢固,避免松动或脱落导致设备故障。

4. 请勿在潮湿、腐蚀性或易燃易爆环境中使用温度控制器,以免引发安全事故。

5. 在长时间不使用时,建议将温度控制器断开电源,并储存在干燥、通风良好的地方。

6. 如果发现异常情况或设备故障,请立即断电并寻求专业人员进行维修。

以上是温度控制器的说明书,希望能帮助您正确、安全地使用该设备。

如有任何疑问或问题,请咨询售后服务部门,感谢您的支持与配合。

注:本说明书仅供参考,请以实际产品附带的说明书为准。

电控制温度调节阀使用说明书(标准版)

电控制温度调节阀使用说明书(标准版)
3. 主要技术参数 3.1 工作介质:淡水、海水、滑油和热油; 3.2 电控阀的不灵敏度不大于 1℃; 3.3 电控阀的相对泄漏量不大于 3%; 3.4 电控阀的最大工作压力 1.0MPa; 3.5 电控阀具有手动控制装置; 3.6 电控阀在下列环境条件下正常工作:
3
a. 环境温度:0~+55℃; b. 相对湿度:95%±3%; c. 油雾和盐雾; d. 各方向倾斜及摇摆 22.5°,周期 10s; e. 振动:频率 2~13.2Hz,位移 1mm;频率 13.2~100Hz,加速度 1G。
南京帝伯热学有限公司 技术开发科
文件代号 适用型号
NT-OMRON-SET OMRON-E5EN-C3T
编制 审核
日期
电控制温度自动调节阀
(PID 控制)
NT2.120.001JS
使用说明书
南京帝伯热学有限公司
1
目录
第一章 概述 第二章 系统构成
系统及接线图 动作原理 系统技术参数 第三章 系统部件说明 阀体 传感器 温度调节仪 安装注意事项 第四章 系统工作 起动 设定温度的更改方法 工作过程 第五章 维护保养 第六章 故障排除
2
第一章 概述
电控式温度自动调节阀(简称电控阀)主要用于控制温度精度要求较高的主机、发电机组、润滑设 备等冷却系统中的淡水、海水、滑油温度的自动调节,控制精确,温度设定灵活,具有报警功能,适合 于计算机集中监控。
第二章 系统构成
1. 系统及接线图
2. 动作原理 铂电阻安装在被检测温度的场所,当流体温度发生变化时, 铂电阻阻值发生变化传至温度调节仪, 温度调节仪处理后输出 DC4~20mA 信号,电动执行器接受到该信号就转动。 转阀的转动角度与电流信号大小有关,转动时调整 B 口(旁通)和 C 口(冷却)的开度,控制流 量,最终控制温度。 温度调节仪采用二个自由度 PID 控制方式,具有快速响应、无过冲、抗干扰好等特点。 (*)电流信号与开度的关系(逆动作场合)

三点旋转故障气温控阀门电机说明书

三点旋转故障气温控阀门电机说明书

NRFD230A-3 Array3-point rotary actuator with fail-safe for ballvalves• Torque motor 5 Nm• Nominal voltage AC 100...240 V• Control 3-point• Deenergised closed (NC)Technical dataElectrical data Nominal voltage AC 100...240 VNominal voltage frequency50/60 HzNominal voltage range AC 85...265 VPower consumption in operation 5 WPower consumption in rest position 3 WPower consumption for wire sizing16 VAConnection supply / control Cable 1 m, 4 x 0.75 mm²Parallel operation Yes (note the performance data)Functional data Torque motor5 NmTorque fail-safe5 NmDirection of motion motor Y = 0 (A – AB = 0%)Direction of motion fail-safe Deenergised NC, valve closed (A – AB = 0%)Manual override NoRunning time motor35 s / 90°Running time fail-safe<20 s @ -20...50°C / <60 s @ -30°CSound power level, motor45 dB(A)Position indication MechanicalService life Min. 60'000 fail-safe positionsSafety data Protection class IEC/EN II, reinforced insulationProtection class UL II, reinforced insulationDegree of protection IEC/EN IP54Degree of protection NEMA/UL NEMA 2Enclosure UL Enclosure Type 2EMC CE according to 2014/30/EULow voltage directive CE according to 2014/35/EUCertification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14UL Approval cULus according to UL60730-1A, UL60730-2-14and CAN/CSA E60730-1The UL marking on the actuator depends onthe production site, the device is UL-compliantin any caseType of action Type 1.AARated impulse voltage supply / control 2.5 kVPollution degree3Ambient humidity Max. 95% RH, non-condensingAmbient temperature-30...50°C [-22...122°F]Storage temperature-40...80°C [-40...176°F]Servicing maintenance-freeWeight Weight 2.0 kgNRFD230A-3•••••••Mode of operationSimple direct mounting Adjustable angle of rotationHigh functional reliabilityWire colours:1 = blue 2 = brown 3 = white 4 = whiteSafety notesThis device has been designed for use in stationary heating, ventilation and air-conditioning systems and must not be used outside the specified field of application, especially in aircraft or in any other airborne means of transport.Outdoor application: only possible in case that no (sea) water, snow, ice, insolation or aggressive gases interfere directly with the device and that it is ensured that the ambient conditions remain within the thresholds according to the data sheet at any time.Caution: Power supply voltage!Only authorised specialists may carry out installation. All applicable legal or institutional installation regulations must be complied during installation.The device may only be opened at the manufacturer's site. It does not contain any parts that can be replaced or repaired by the user.Cables must not be removed from the device.The device contains electrical and electronic components and must not be disposed of as household refuse. All locally valid regulations and requirements must be observed.Product featuresThe actuator moves the valve to the operating position at the same time as tensioning thereturn spring. The valve is turned back to the fail-safe position by spring force when the supply voltage is interrupted.Simple direct mounting on the ball valve with only one screw. The mounting orientation in relation to the ball valve can be selected in 90° steps.Adjustable angle of rotation with mechanical end stops.The actuator is overload protected, requires no limit switches and automatically stops when the end stop is reached.Electrical installationCaution: Power supply voltage!Parallel connection of other actuators possible. Observe the performance data.Wiring diagramsAC 230 V, 3-pointNRFD230A-3 DimensionsFurther documentation• The complete product range for water applications• Data sheets for ball valves• Installation instructions for actuators and/or ball valves• General notes for project planning。

SX90 090低厚双三孔空气 氮控制阀门说明书

SX90 090低厚双三孔空气 氮控制阀门说明书

Instruction Manual SX90/090Low Profile 2/3 Port Solenoid ValveThe intended use of the SX90/090 is for the control of air/nitrogen in the down-stream pneumatic circuit.These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.”They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) *1), and other safety regulations. *1)ISO 4414: Pneumatic fluid power - General rules relating to systems. ISO 4413: Hydraulic fluid power - General rules relating to systems.IEC 60204-1: Safety of machinery - Electrical equipment of machines. (Part 1: General requirements)ISO 10218-1: Manipulating industrial robots -Safety. etc.• Refer to product catalogue, Operation Manual and Handling Precautions for SMC Products for additional information. • Keep this manual in a safe place for future reference.Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.WarningWarning indicates a hazard with a medium level of riskwhich, if not avoided, could result in death or serious injury.DangerDanger indicates a hazard with a high level of risk which, ifnot avoided, will result in death or serious injury.Warning• Always ensurecompliancewith relevant safety laws and standards.•All work must be carried out in a safe manner by a qualified person in compliance with applicable national regulations.2.1 General specificationsTable 1.1) Flow rate is calculated at pressure difference of 0.2 MPa 2) Based on JIS B 8373 (SX91/92) & JIS B8419 (SX090)2.2 Coil specificationsTable 2.1) Power-saving type requires rated voltage to be supplied continuously, for power saving characteristics to take effect.2) When using a valve without the power saving circuit, energise asshown in figure 1. using the voltages from table 2.3) Ensure the inrush time (100±10 msec) is reached before lowering to the holding voltage to ensure clean switching of the valve.Figure 1. Energisation waveform3 Installation3.1 MountingWarning• Do not install the product unless the safety instructions have been read and understood.• Do not apply force to the coil or frame when installing valve. Malfunction may occur if force of 10N or more is applied • Confirm that the gasket is correctly mounted on the body.• Tighten mounting screws, evenly, to the required tightening torque. Guide torque value is 0.10 to 0.14 N•m. Adjust according to environment.Figure 2. SX91/92 Manifold footprint dimensionsFigure 3. SX090 Manifold footprint dimensionsFigure 4. SX90 FootprintFigure 5. SX090 Footprint3.1 EnvironmentWarning• Do not use in an environment where corrosive gases, chemicals, salt water or steam are present.• Do not use in an explosive atmosphere.• Do not expose to direct sunlight. Use a suitable protective cover.• Do not install in a location subject to vibration or impact in excess of the product’s specifications.• Do not mount in a location exposed to radiant heat that would result in temperatures in excess of the product’s specifications.3.2 PipingCaution• Before connecting piping make sure to clean up chips, cutting oil, dust etc.• When installing piping or fittings, ensure sealant material does not enter inside the port. When using seal tape, leave 1 thread exposed on the end of the pipe/fitting.3.3 LubricationCaution• SMC products have been lubricated for life at manufacture, and do not require lubrication in service.3.4 Electrical connection• Avoid mis-wiring, as this can cause malfunction and damage to the product.• To prevent noise and surge in signal lines, keep all wiring separate from power lines and high voltage lines. Otherwise this can cause malfunction.• When a surge from the solenoid affects the electrical circuitry, install a surge absorber, etc., in parallel with the solenoid.• Use electrical circuits that do not generate chattering in their contacts. • For the standard valve use voltage that is within ±10% of the rated voltage. For the power saving type use voltage 0 to +10% of the rated voltage.• Do not pull the lead wire. Damage may occur if force of 10N or more is applied.3.5 Electrical circuitsFigure 6. Standard type – Without power saving circuitFigure 7. With power saving circuit integratedRated VoltageLead wire colour 1 2 DCRed BlackTable 3.Model SX91 SX92 SX090 Valve Structure 2 Port Direct Operated Solenoid Valve2 Port Direct Operated Solenoid Valve3 Port Direct Operated Solenoid Valve Switching Method N.C.Universal UniversalWorking FluidAir, Nitrogen Operating Pressure range (MPa)-100kPa~0.2Proof Pressure (MPa) 0.6Ambient Temp. (°C)0~50 0~50 0~50 Flow CharacteristicsC[dm 3/(s.bar)0.25 0.12 0.5 b 0.25 0.25 0.3 Cv 0.07 0.032 0.14 L/min(ANR) 1)452290Response Time (on/off) 2) ≤10 ms≤15 msShock/Vibration Resistance (m/s 2)150/30 Mounting OrientationFree IP Rating IP40 Weight (g)101020ModelSX91/92SX090 Power Saving Type1)Rated Voltage DC12VDC24VDC12VDC24VPower ConsumptionStart-Up 4W6W Hold-On 0.7W0.8WNon Power Saving Type 2)Start-Up VoltageDC12V DC24V DC12V DC24V Power Consumption 4W 4W 6W 6W Hold-On3)VoltageDC5V DC10V DC4.2V DC8.4V Power Consumption 0.7W0.7W0.8W0.8W Allowable VoltageFluctuationStandardType ±10% of Rated Voltage Power Saving Type0 to +10% of Rated VoltageCoil Insulation TypeClass BORIGINAL INSTRUCTIONSRefer to Declaration of Conformity for relevant Directives1)SX91 2)SX92 3)SX090 1) 2)3) 2xM2x0.4 (Thread depth >6mm)Hold onRated VoltageSX90 SX090Start-upRated Voltage (Thread depth >6mm)C0.2 or Less2xM2x0.4 (Thread depth >6mm)(Minimum depth 2.2mm) Power Saving CircuitSol.4.1 Manual OverrideCaution• For SX090. Push the Ø3mm button in the direction shown by the arrow to engage the manualoverride. Travel of button should be approximately 0.5 mm. The valve will be turned off when the button is released.Figure 8. SX090 Manual Override• Refer to catalogue for ‘How to Order’.• Refer to catalogue for outline dimensions.7.1 General MaintenanceCaution• Not following proper maintenance procedures could cause the product to malfunction and lead to equipment damage.• If handled improperly, compressed air can be dangerous.• Maintenance of pneumatic systems should be performed only by qualified personnel.• Before performing maintenance, turn off the power supply and be sure to cut off the supply pressure. Confirm that the air is released to atmosphere.• After installation and maintenance, apply operating pressure and power to the equipment and perform appropriate functional and leakage tests to make sure the equipment is installed correctly.• If any electrical connections are disturbed during maintenance, ensure they are reconnected correctly, and safety checks are carried out as required to ensure continued compliance with applicable national regulations.• Do not make any modification to the product.• Do not disassemble the product, unless required by installation or maintenance instructions.8.1 Limited warranty and Disclaimer/Compliance Requirements • Refer to Handling Precautions for SMC Products 8.2 Extended Periods of Continuous EnergisationCaution• Do not energise continuously at rated (start-up) voltage if no energy-saving circuit is included. This may damage the coil.• Make sure coil surface temperature does not exceed 80°C if the valve is continuously energised at the holding voltage.• After continuous energisation, do not touch the valve by hand. Coil temperature may be high due to extended period of energisation.• If the coil is likely to be touched, use a protective cover for the valve and provide a warning label according to local regulation.• If 3 or more adjacent coils are continuously energised in a manifold assembly, make sure fluid supply is maintained to avoid temperature rise above 80°C. 8.3 Response time reduction• Response time may become extremely slow under the following conditions:When the valve is energised for the first time after a long period of de-energisation.When the operating pressure is low (0.1MPa or less). When the ambient temperature is 10°C or less.8.1 Applicable FluidsCaution• Please contact SMC before using the valve with a fluid other than air or nitrogen.This product should not be disposed of as municipal waste. Check your local regulations and guidelines to dispose this product correctly, in order to reduce the impact on human health and the environment.10 Limitations of UseRefer to or www.smc.eu for contacts.URL : http// (Global) http// (Europe)'SMC Corporation, Akihabara UDX15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101 0021Specifications are subject to change without prior notice from the manufacturer.© 2020 SMC Corporation All Rights Reserved.Template DKP50047-F-085I。

温控器使用说明

温控器使用说明

温控器使用说明KO温度控制器使用说明书1.温度设定方法:按▲(上键)和▼(下键)按2下,在画面闪动的时候,按▲或▼,可设定希望的温度。

2.偏差温度设定(设定温度与启动温度,温差设定)▲(上键)与▼(下键)同时按3秒会显示“dlF”字母,按▲或▼可以调节温差。

3.温度矫正方法先按▲,再按电源,3秒后会显示“Cor”继续按3秒会校正为℃(出厂设定为℃,设定范围为±10℃)4.特殊功能调节先▼(下键)按往不动,再按电源,会显示“ty2”继续按3秒,可设定所有的功能,每按一次电源,会显示各种菜单。

“ty2”为温感线感应温度。

5.时段供电温度调节方式按▲(上键),会显示“stp”继续按3秒,会显示1-5时段显示,出厂1档,设定范围0-5挡。

以下表格为各档送电和停电的时间表。

*档位越高温度越高,停止和供电方式反复工作*1档以上开始时自动供电。

6.定时关机设定方法▼(下键)按住3秒钟,显示“t_t”继续按3秒,在“too”状态,可设定定时关机功能,设定时间范围0-99个小时。

设定时间内正常工作,到了时间自动关机(出厂设定为0时)如显示“to9”9个小时就会自动关机,设定关机时间,会显示剩下多少时间,剩余时间显示“t11”就是剩11小时,“”就剩余8个小时50分钟。

定时,时间的变动,关机重启的话变成“0”。

*故障显示:—温感探头出现问题,它显示3秒后,自动转换成定时供电功能,温感探头恢复正常工作的话,重新转换到温度感应工作状态。

—记忆功能出现问题,停止输入电能,掐断电源,重新投入使用,要检查各功能是不是出厂状态。

OUT 输出(负载),IN 输入(220V)。

温控阀使用手册

温控阀使用手册

. . . .电动温控阀工达科技产品使用手册济南工达捷能科技发展有限公司(二零一一年第八版)(提示:请妥善保管本手册,以备急需,遗失不补!). . . .前言尊敬的客户:您好,感谢您选用济南工达捷能科技发展有限公司为您提供的温控阀系列产品。

我公司经德国SIEMENS楼宇科技公司正式授权代理,并被SIEMENS公司评为优秀合作伙伴,负责SIEM EN S楼宇科技公司暖通空调控制类产品的技术推广、产品推广、技术服务以及产品销售和售后服务工作。

在我们为您提供温控阀系列产品的同时,更为您展现出优质的服务和专业的技术实力,以及工达人的敬业精神和全方位为客户着想的工作态度。

在您选用我们的产品之时,我们已根据您的订货要求进行了参数和程序设定。

尽管如此,为了进一步保证设备正确安装、使用和维护保养及时,仍建议您仔细阅读本《使用手册》。

如果您需要重新设定或更改参数,更应进一步阅读,如有疑问,可致电您的供应商或与我们联系,我们的工程技术人员在接到您的咨询要求后,一定会竭力为您提供满意答复。

济南工达捷能科技发展有限公司全体员工再次感谢您对我们公司的信任与支持!. . . .注意事项1、 SIEMENS公司在不断的追求产品的优化和性能的改进,因此我们同时保留在没有作出通知的情况下对本版说明书进行修改的权利。

2、本着对用户负责的工作态度,本手册的编制过程中,我们尽可能地为用户的安装维护提供全面的指导和建议。

由于本产品使用现场的复杂性和多样性,本《使用手册》不可能尽述,欢迎广大用户在使用过程中提出宝贵意见,以利于我们更好地改进服务工作。

3、工达公司不可能强调到所有潜在危险的情形。

因而,用户在使用时,除严格遵守本《手册》要求外,务请参考国内相关或近似标准的要求使用,不同标准之间有冲突时,请参考较高级要求之标准。

4、本《使用手册》中所提及产品及使用说明是专门针对于暖通空调设备而言的,若用于其它工况,建议由专业人员根据工艺要求进行控制逻辑分析,或与我公司经销商联系,我们的工程技术人员一定会竭尽全力给您满意的答复和建议。

温度控制器操作说明

温度控制器操作说明

温度控制器操作说明
1、将仪表连线接妥后,将开关拨至“下限设定”处,同时旋转相对应的下限设定旋钮,此时数字显示的是所需的下限温度值。

2、将开关拨至“上限设定”处,同时旋转相对应的上限设定旋钮,此时数字显示的是所需的上限温度值。

3、再将开关拨至“测量”处,数字显示的是被测对象的实际温度值。

4、当实际温度值低于下限设定值时,绿灯亮,上限继电器均为总低通,总高断;当实际值达到或超过下限设定值而仍低于上限设定值时,绿灯红灯均熄灭、下限继电器总低断、总高通、上限继电器为总低通,总高断、当实际值达到或超过上限设定值时,红灯亮,此处对上限继电器均为总低断、总高通。

5、一般作温度控制时可把下限继电器输出辅助加热控制、上限作加热控制,也可把下限继电器输出作温度控制,而把上限继电器输出作超温报警。

后缀加“F”的仪表,上限所需温度值必须调整到高于下限所需温度高值。

6、当实际值低于下限值时绿灯亮,继电器总低通,升温;当实际值高于下限值且低于上限值时仍为总低通,升
温;当实际值高于上限值时,红灯亮,继电器总高通、总低断开,停止加温,只有当实际温度值低于下限值时,绿灯亮,总低通,周而复始。

整个过程只有一个继电器输出,以便与负载方便地配接。

温度控制器使用说明书

温度控制器使用说明书

温度控制器使用说明书一、产品概述温度控制器是一种用于控制和调节温度的设备。

它可以实时监测环境温度,并按照预设的温度范围进行自动控制,以确保温度保持在设定值内。

二、产品组成1.主机:包含显示屏、按键和控制电路等组件,用于设置和监控温度控制器的工作状态。

2.传感器:用于感知环境温度的变化,并将其转化为电信号,传输给主机进行处理。

3.输出端口:用于连接外部设备,如加热器、冷却器等,以实现温度调节。

三、使用步骤1.连接电源:将温度控制器插入电源插座,并确保电源稳定。

2.连接传感器:将传感器插入温度控制器的传感器接口中,并确保连接牢固。

3.设置温度范围:按照产品说明书中的指引,通过按键设置所需的温度范围。

4.连接外部设备:根据需要,使用合适的电缆将外部设备连接至温度控制器的输出端口上。

5.开机:按下电源按钮,温度控制器将开始运行,并在显示屏上显示当前温度及工作状态。

6.调试和调节:根据实际需要,适时调整温度控制器的参数,以达到预期的温度控制效果。

四、注意事项1.请确保温度控制器在通风良好的环境中工作,避免遮挡或靠近高温的物体。

2.避免温度控制器长时间暴露在潮湿、尘土等有害环境中,以免影响正常使用寿命。

3.使用前请认真阅读产品说明书,并按照要求正确操作,以免因误操作导致设备损坏或操作失误。

4.在设置温度范围时,请合理选择上下限,避免因温度波动过大造成设备故障或无法达到所需温度。

5.如遇到温度控制器异常工作或其他问题,请及时联系售后服务中心进行咨询或维修。

五、常见问题解答1.温度控制器显示屏无法正常工作怎么办?答:请检查电源接口是否接触良好,确认电源供电充足,并检查是否有异常开关或损坏的部件。

2.温度控制器无法控制温度在设定范围内怎么办?答:请确认传感器连接是否正确,温度控制器和外部设备的连接是否稳固,并适时调整温度范围和控制参数。

3.温度控制器显示温度与实际温度不一致怎么办?答:请检查传感器的位置是否合理,避免受到外部干扰,如阳光直射或其他热源等。

温控器使用说明书

温控器使用说明书

一周编程电子智能室内温控器LOGIC 578001使用指南引言感谢您选择了我们的产品及对我们的信任与支持。

本装置是电子式定时恒温器,可设置一星期为周期的运行程序。

通过该装置,可对安装环境内的温度进行十分精确的调节控制,满足用户对创造一个舒适生活环境的要求。

符合标准:符合欧盟法令:EN 60730-1 标准及其修订内容欧盟B.T.73/23/EEC号法令EN 60730-2-7 标准欧盟 E.M.C.89/336/EEC号法令及93/68/EEC修改法令EN 60730-2-9 标准产品规格:电源:二节LR6型1.5V碱性电池温度调节范围:10至35℃显示屏显示之环境温度:0至40℃(分辩率0.1℃)温度修正频率:每分钟一次微分:0.2至0.4K探针传感器:NTC3%保护等级:IP20绝缘等级:热梯度:1K/15分输出:转换继电器触点容量:8(2.5)A250V~作用类型:1BU绝缘条件:正常环境最大工作温度:50℃储存温度:0-60℃防冻温度:6℃恒定运行程序:以一星期为周期设置软件等级:A液晶显示屏夏季/冬季(采暖/空调)切换程序设置中的最小增减允许时间:1小时安装:壁式安装安装及连接:安全预防措施在进行定时恒温器的连接之前,请确认受其控制的设备系统(采暖锅炉、泵和空调系统等)电源已断开,并需检查这些设备的使用电压是否与定时恒温器底座上表明的电压相符(最大250V~).(图4)安装位置定时恒温器须安装在远离热源(暖气装置、阳光、厨房)和门窗之处,安装高度离地面约1.5米。

(图5)安装见图6-7-8电气连接将受定时恒温器控制的设备系统电线与定时恒温器的1号及2号接线柱连接见接线图10所示U=受定时恒温器控制的设备1=共用接线柱2=常开接线柱3=常闭接线柱重要事项:请务必严格遵照相关现行法律的规定及安全规范安装定时恒温器。

电池更换:当在显示屏上闪烁显示“”标志时,定时恒温器还可正常工作约一个月左右,然后将会停止工作并固定显示“”。

温度控制器操作说明书

温度控制器操作说明书

温度控制器操作说明书一、产品概述温度控制器是一种用于自动调控设备温度的智能电子仪器。

通过采集温度数据,并根据预设的温度范围进行控制,实现精确的温度控制和调节。

本操作说明书将为您详细介绍温度控制器的使用方法和注意事项。

二、产品外观和组成1. 外观描述温度控制器外观小巧精致,采用黑色塑料材质。

正面配备液晶显示屏和按键控制区域,底部有插孔用于连接传感器。

整体设计简洁大方,符合人体工学原理,易于操作。

2. 组成部件温度控制器由以下主要部件组成:(1) 显示屏:采用液晶技术,以数字方式实时显示当前温度和设定温度。

(2) 控制按键:包括上、下、确定等按键,用于设置和调节温度参数。

(3) 传感器插孔:用于插入温度传感器连接线,将温度数据输入到控制器中。

三、使用方法1. 上电及初始化将温度控制器插头与电源插座连接,按下控制器背面的电源开关,控制器即可供电并初始化显示正常。

2. 温度控制设置(1) 按下控制器上的“设定”按钮,进入温度设定模式。

(2) 使用上下按键选择您需要的温度设定值,按下“确定”按钮确认设定。

3. 温度读数显示(1) 控制器将实时显示当前温度数值,您可以通过温度单位按钮切换摄氏度或华氏度显示。

(2) 当温度达到设定值时,控制器将发出声音提示,并停止加热或制冷操作。

4. 温度报警功能(1) 温度控制器具备温度报警功能,当温度超出设定范围时,控制器将发出报警声音,并在显示屏上闪烁提示。

(2) 若出现温度超出设定范围的情况,请立即检查设备故障并采取相应措施以避免损坏。

5. 温度控制模式切换温度控制器支持手动模式和自动模式的切换。

您可以根据需要选择手动模式或自动模式进行温度控制。

(1) 手动模式:您可以通过手动设定的方式控制温度升高或降低。

(2) 自动模式:温度控制器将根据您设定的温度范围自动进行温度控制,保持设备处于所需的温度状态。

四、注意事项1. 使用环境请确保在干燥、通风良好的环境中使用温度控制器,并避免阳光直射、潮湿或过于高温的环境。

AT Controls Series 90 93拆体式流动筒球阀说明说明书

AT Controls Series 90 93拆体式流动筒球阀说明说明书

90_93Series-20180411Copyright 2013 A-T Controls, Inc.Cincinnati, Ohio FAX (513) 247-5462********************See automated data sheets for pre-sized assembliesPneumaticElectricSERIES 90/93 Split Body Flanged Ball ValveTriac 90 Series Flanged Ball Valves feature a split body design. The high quality investment castings feature a fully machined bore. The superior live-loaded packing system is accomplished with Belleville washers, “V” ring packing and a unique primary pyramidal stem seal. This advanced sealing system provides protection against stem leaks experienced byvarious options are avail-able for seat materials. The 50/50 STFE seat option is excellent for services that call for higher temperatures and more difficult applications including steam. Call us for details.Chevron PackingHigh Performance, Full Port Split Body Flanged Ball Valve Series 90 (ANSI Class 150)A-T Controls reserves the right to change product designs and technical/dimensional specifications without notice.9955 International Blvd.Cincinnati, Ohio PHONE (513) 247-5465FAX (513) 247-5462********************material, consult factory.DIMENSIONS (IN)Series 93 note:D ue to differences between sand cast and investment cast valves, A-T Controls requires that each valve be measured for the correct stem height and width before making a mounting adaption.Standard manual valves should be ordered with an automation gland if A-T Controls is not making the mounting kit.Dimensions B, E, and Y are for reference only.Pressure vs. Temperature ChartTEMPERATURE IN °F (°C)P R E S S U R E I N P S I GPRESSURE IN BAR(-28)050100150200250(-18)(38)(93)300350400450500550(204)(149)(260)03.56.9101417212428313438(316)NOTE: Dotted line shows the rating for valve body. Solid line shows the rating for valve seat. Both ratings need to be considered when determining the limitation of the valve for specific application. Consult factory for other seat materials.*QTY = 8 PCS for 2-1/2” THRU 6” QTY = 12 PCS for 8” QTY = 16 PCS for 10” THRU 12”» Call for material detailson Hastelloy C-276 valves**O-Ring n/a on 93 series (6”-12”)90_93DA-20160121Copyright 2013 A-T Controls, Inc.SERIES 90/93 150# FlangedCincinnati, Ohio FAX (513) 247-5462********************90_93SR-20160121 Copyright 2013 A-T Controls, Inc.Cincinnati, Ohio 45246 FAX (513) 247-5462 ********************150# FlangedSee valve part number matrix for complete part number and options.SAMPLE PART #Other options available - call for details. Actuators are sized based on clean/clear fluid.Chevron PackingSeries 90_93EL-20160121Copyright 2013 A-T Controls, Inc.Cincinnati, Ohio FAX (513) 247-5462********************See valve part number matrix for complete part number and options.(2) auxiliary switches standardOther options available - call for detailsActuators are sized based on clean/clear fluid.SERIES 24 Direct MountSERIES 90/93 150# Flanged DIMENSIONS (IN)150# FlangedChevron PackingManual and automated valve assemblies for gas burner management applicationsand safety shutoffVarious Seat MaterialsPTFE, RTFE, 50/50 STFE, 25% CTFE, Delrin,PEEK, UHMWPE, TFM-1600Operator OptionsQuarter-turn Gear OperatorsSpring Return “Deadman” HandlesOval handles, TEE HandlesSpecials and SolutionsSteam JacketsStem ExtensionsV-ported Control ValvesMulti-port Valve SolutionsFugitive Emissions Bonnets (TSM’s)Oxygen CleaningLockout BracketsVented Balls“No Play” Mounting Kits• FM ApprovedValves and AssembliesSpecial SeatsBalls and Seal DesignsFloor MountedDamper DrivesFusible LinkAssembliesLockoutMounting KitsSpecialMulti-Port ValvesSteam JacketedValvesLimit SwitchesMounted on Manual Valves180º ActuatorsStem ExtensionsDual ValveAssembliesCincinnati, Ohio 45246FAX (513) 247-5462********************。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
100
out %
100
out %
100
28
C
90 80 70 60 50 40 30 20 10
68
C
90 80 70 60 50 40 30 20 10
68
C
90 80 70 60 50 40 30 20 10
阀门 开 度 显示 方 式
25
180
Tvne
0 :上电时阀门全关,阀门开度显示设定0 %,关电时不存储 1 :上电时阀门不关,阀门开度显示设定0 %,关电时不存储 2 :上电时阀门不关,阀门开度显示原来开度,关电时存储 3 :上电时阀门不关,阀门开度显示原来开度,关电时不存储 注:0 - 3代码,开度显示器显示阀门开度 4 :开度显示关,其它同YSY = 0 5 :开度显示关,其它同YSY = 1 6 :开度显示关,其它同YSY = 2 7 :开度显示关,其它同YSY = 3
179
C
90 80 70 60 50 40 30 20 10
双击
返回 主 界面
179
C
90 80 70 60 50 40 30 20 10
180
双击 按
进入 手动操 作 可以进 行
Nan
二.端 子 接 线
T90
手 动 开 阀/关 阀
T90
4 . 3 :查看控制器通讯地址
out %
100
out %
100
七.参数说明
输 出 不感带 D B :此 参 数 可以避 免 电机 频 繁动 作,延长电机 使 用寿 命 合 理 调节DB值 可 以达 到 温度控 制 精度 与 电 机使用 寿 命的兼 顾
八.技术规格
电 源 电 压: 10 0 - 24 0V A C 50 HZ / 6 0H Z 电 源 功 率 :5 VA m ax 输 入 类 型 :p t1 00三线/热电 偶 输 入 精 度 :1 2b it D / A 输 出 类 型 : 继 电 器 5A m ax / 4 - 2 0m A 环 境 温 度 :- 25°C - - 6 0°C 外 形 尺 寸 :9 6 * 96 * 1 20 mm ( T 90 ) 4 8 * 9 6 * 12 0m m ( T8 0 ) 通 讯 方 式 :R S4 85 M OD BU S - RT U 通 讯 速 率 :1 20 0 24 00 4 80 0 9 60 0 192 00 bp s
A1 . A
九.产品选型
4 7 4 7 4 7
无控制输出 控制输出 无控制输出
注:当A1 . A > 0时为上偏差报警,继电器动作值: SP + A1 . A 继电器复归值= SP + A1 . A - HY . 1 < HY . 1报警滞后值> 当A1 . A < 0时为下偏差报警,继电器动作值: SP - A1 . A 继电器复归值= SP - A1 . A + HY . 1 < HY . 1报警滞后值> AI . A值的正负,仅代表偏差动作方向。
参数代码
参数名称
参数 设 定 密 码 PID自动演算 比例 带 积分 动 作 时 间 微分 动 作 时 间 输出 不 感 带 马达 运 行 时 间 报警 类 型 偏差报 警 值 上限下 限 报 警 值 带宽报 警 值 报警回 差 小数点 位 量程下 限 量程上 限 设定值 下 限 设定值 上 限 第二设 定 点 设定点 斜 率 控 制 斜率控制方 式 第 二 设 定点延迟 控制 过 程 增 益 信号 滤 波 常 数 感温 回 路 故 障 时 阀门动作方 式 手动 功 能 控制 类 型 第二 设 定 点 外 控 第二 设 定 点 开 启 第二 设 定 点 关 闭 第二设 定 点 停 止 温度 校 正
参数说明
当PAS = 1时有效,原始密码= 1500 ;当PAS = 0时不显示 0 :不可执行自动演算;1:可执行自动演算 1 . 0 %- 999 . 9 % ( PB = 0和tn > 0 ON - OFF / OFF - ON控制方式) 1 - 2600秒,当tn = 0时,ON - OFF控制方式 1 - 255秒,td = 0时为PI控制模式 0 -全量程 5 - 300秒,阀门全关到全开时间 0 :无报警 1 :偏差报警( A1A =偏差报警值) 2 :绝对值上限报警( A1B =报警值) 3 :带宽报警(A1C =报警值) 4 :绝对值下限报警( A1B =报警值) 报警值: AL = 0时参数不显示 AL = 1时显示A1A AL = 2 / 4时显示A1B AL = 3时显示A1C:会出现2次A1 . C 设定为负值时为带宽下限,设定正值为带宽上限 0 -全量程 注:当AL . 1 = 3时,会出现2个报警滞后 0 :没小数点 1 / 2 / 3 :对应小数点后几位数 - 999到量程上限- 1;出厂时设定,切勿变更 量程下限+ 1至量程上限;出厂时设定,切勿变更 范围:量程下限至设定值上限 范围:设定值下限值量程上限 范围:量程下限-量程上限,远程接口控制时有效 0 -全量程,(单位: C / Min 或 C / hr );= 0时无斜率控制功能 0 :升温/降温均斜率控制 1 :升温时斜率控制 2 :降温时斜率控制 0 / 1 / 2时单位:C / Min 3:无斜率控制 4 / 5 / 6 :与0 / 1 / 2控制方式一样,单位:C / hr 与外控STD配合使用 1 %- 255 %;系统温度改变量对输出改变量的比值,自动演算用 0 - 255 (相当于0ms - 10s ) 0 :阀门全关 1 :阀门全开 2:阀门原位,不动作 0 :手动功能有效;1:手动功能锁定 0 :反向动作(加热控制用); 1 :正向动作(冷却控制用) 数位输入 数位输入 数位输入 数位输入 0全量程
T80 / T90
阀门温度控制器使用说明书
一.主 要 特 点 :
1 .仪 表 采 用热 电 阻P T 1 0 0输 入 , 具 有 较 高 的 控 制 精 度 2 .分 辨 率 :1 2 B i t A / D 3 .输 出 类 型 : 开 关 触 点 输 出 :5 A 2 5 0 V A C m a x 4 .设 定 点 控 制 和r a m p斜 坡 温 度 控 制 两 用 功 能 5 .智 慧 型P I D自 动 演 算 功 能 , 实 现 无 超 调 的 控 制 性 能 6 .阀 门 开 度 显 示 7 .过 程 与 回 路 报 警 : 过 程 高 报 警 , 过 程 低 报 警 , 偏 差 报 警 带宽报警,探头回路的短路与断线报警 8 . R S 4 8 5 M O D B U S - R T U通 信 , 可 以 组 网 控 制 9 .二位置式控制( ON - OFF ) 和三位置式控制(ON - OFF / OFF - ON )
out %
100
三.面板 说 明
报警指示
键进入自动演算。见下面图例
out %
100
out %
100
28
C
90 80 70 60 50 40 30 20 10
Opt
C
90 80 70 60 50 40 30 20 10
Opt
C
90 80 70 60 50 40 30 20 10
25
out %
100
0
1
0 : 19200bps 1 : 9600bps 2 : 4800bps 3 : 2400bps 4 : 1200bps
当前设定值
T90 T90 T90
b d 通讯 波 特 率 a d r 通讯 地 址 s .c o l .2 pas
界面设 定 方 式
范围: 1 - 247 0 :上位机和控制器可以同时设定温度值 1 :只能由上位机设定温度值,控制器只能设定参数 0 :不设定 1 :自动演算 2 :报警和报警回差设定 4 :无功能 8 :第二设定点SP2数值设定 16 :设定点斜率控制 0 :控制参数/控制阶层不锁定 1 :控制参数锁定(密码:1500 )
开阀指示 关阀指示
当前温度值
1 8 0C 180
90 80 70 60 50 40 30 20 10
阀门位置显示
T90
T90
T90

键2S以上
进入参数设置模式, 修改OPT = 1

键2S以上退出
nan dir s 2 .d o p .d c l .d s t .d c .c o y .s y
out %

修改设定值

键,进入演算模式
T90
功能键,参数进入与退出 参数与设定值确认键 温度设定值修改 参数值修改
自动演算中 Sp窗口:设定温度值与 T V N E 交替显示
注:如果要取得更好的控制效果,可以再执行一次自整定
第 二 操作阶层 参数锁定
六.报警类 型
6 . 1 :偏差报警 A L . 1 = 1
T x0
输 出不感 带
6 . 2 :绝对值上限报警 A L . 1 = 2 绝对值下限报警 A L . 1 = 4
输出不感带在以下两种控制方式的应用 见图例
T80 T90
3线 制RTD
线性电流输出4 - 20mA
7 4 7 4 7 4 7 5 7 6
3
7 . 1 : 三点步进控制方式
当 A L . 1 = 2 时,PV值> A1 . B时继电器动作,继电器复归= A1 . B - HY . 1 当 A L . 1 = 4 时,PV值> A1 . B时继电器动作,继电器复归= A1 . B + HY . 1
6 . 1 :带宽报警 A L . 1 = 3
7
4 7 4 7 4 7 4 7 4 7
5
7
6
7
5
7 . 2 : 二点 ON / OFF控制方式