巴西插头和插座标准

合集下载

世界各国家与地区电压及插头一览

世界各国家与地区电压及插头一览

世界各国家与地区电压及插头一览世界各国家与地区电压及插头一览国家与地区电压插头阿根廷220V, 50Hz 双孔圆型、3个扁平头型以三角形排列澳洲220V, 50Hz 3个扁平头型以三角形排列奥地利230V, 50Hz 双孔圆型巴林230V, 50Hz 三孔方脚比利时220V, 50Hz 双孔圆型巴西110/220V, 50Hz 两头扁插及圆插柬埔寨230V, 50Hz 双孔圆型及扁型加拿大110V, 60Hz 双孔扁型及双孔扁型连地线孔智利220V, 50Hz 两孔圆型中国220V, 50Hz 双孔圆型、双孔扁型、三孔圆型克罗地亚230V, 50Hz 双孔圆型古巴110/220V, 60Hz 民居普遍为两孔扁型;但酒店多提供两孔圆型捷克220V, 50Hz 双孔丹麦220V, 50Hz 双孔圆型埃及220V, 50Hz 双孔圆型埃塞俄比亚220V 两脚圆头芬兰220V, 50Hz 双孔圆型法国220V, 50Hz 双孔圆型德国220V, 50Hz 双孔圆型希腊220V, 50Hz 双孔圆型关岛110/220V, 60Hz 双孔扁型及双孔扁型连地线孔匈牙利220V, 50Hz 双孔圆型印度230V, 50Hz 两孔或三孔圆型印度尼西亚127/220V, 50Hz 双孔圆型爱尔兰230V, 50Hz 四方柱三插头以色列220V, 50Hz 3个扁平头型以V形排列及双孔圆型意大利220V, 50Hz 双叉及三叉型日本110V, 50Hz 双孔扁型利比亚127/230V, 50Hz 三孔圆型马来西亚240V, 50Hz 三孔长型马尔代夫230V, 50 Hz 双孔圆型及三孔长型墨西哥127V, 60Hz 双孔扁型及双孔扁型连地线孔文莱220V, 50Hz 三孔长型尼泊尔230V, 50Hz 双孔圆型及扁型荷兰220V, 50Hz 双孔圆型纽西兰240V, 50Hz 三孔或二孔的斜扁头挪威220V, 50Hz 双孔圆型秘鲁220V, 60Hz 双孔扁型、双孔扁型连地线孔及双孔圆型菲律宾220V, 60Hz 双孔扁型及二孔、三孔圆型波兰220V, 50Hz 双孔圆型葡萄牙220V, 50Hz 双孔圆型帛琉110V罗马尼亚230V, 50Hz 双孔圆型俄罗斯220V, 50Hz 双孔圆型塞舌尔240V, 50Hz 三孔平头型新加坡220V, 50Hz 三孔平头型南韩220V, 60Hz 双孔圆型西班牙220V, 50Hz 双孔圆型斯里兰卡230V, 50Hz 三孔圆型瑞典220V, 50Hz 双孔圆型瑞士230V, 50Hz 双孔圆型台湾110V, 60Hz 两孔扁平型泰国220V, 50Hz 双孔圆型及扁型南非220/230V, 50Hz 大三孔圆型美国120V, 60Hz 两脚圆插土耳其230V, 50Hz 双孔圆型阿联酋220V, 50Hz 三孔方脚英国240V, 50Hz 三孔长方型越南220V, 50Hz 双孔圆型及扁型。

巴西插头与插座标准简介

巴西插头与插座标准简介

巴西国内的插头与插座市场很不规范, 市场上充斥着来自全球不同制造商的各种产品。由于没有统一而详细的标准, 巴西市场上的很多插头和插座都没有 达到安全要求, 用户在使用时容易发生危险, 还导致该市场存在很多不合理竞争现象。针对这种情况, 巴西国家标准局Inmetro开始着手为电气产品和发电 装置制定详细而统一的基本安全要求。由巴西技术标准协会电气委员会成立的工作组负责编写有关电气插头与插座的标准——NBR6147和NBR14136。
NBR 14136/02 – FIGURE 14 2 poles without earthing contact (for class II equipment) from 12A to 20A, 250V
NBR 14136/02 – FIGURE 14 2 poles without earthing contact (for class II equipment) from 12A to 20A, 250V
NBR14136标准最新动态
• 由于市场对NBR14136标准的实施有所抵触, 巴西国家权威认证机构 Inmetro于2006年6月与相关机构组成了一个专家小组, 针对新标准对技 术和市场产生的不同影响进行了研讨。尽管专家组没有发布任何讨论结 果, 但Inmetro已经决定重新考虑NBR14136标准的执行时间以及该标准 是否是巴西国内唯一一项关于插头和插座的标准。
• Plug Marking for the 20A 250V~ Plug:
• Cable section of 0.75mm² - 10A 250V~ • Cable section of 1mm² - 12A 250V~ • Cable section of 1.5mm² - 16A 250V~ • Cable section of 2.5mm² - 20A 250V~

世界各国电压及插座规格

世界各国电压及插座规格

中东地区国名 (中文 / 英文) 电压频率插头型式说明俄罗斯 / Russia 220V 50Hz E, F & G 欧洲规格双脚圆型 白俄罗斯 / Ukraine 220V 50Hz E, F & G 欧洲规格双脚圆型沙乌地阿拉伯 / Saudi Arabia 127及220V 60Hz / 50HzA, B & I 两脚扁型 /两脚扁+接地脚 / 英规三脚扁型约旦 / Jordan 220V 50Hz I 英规三脚扁型伊拉克/ Iraq 220V 50Hz E & I 欧洲规格双脚圆型/ 英规三脚扁型叙利亚/ Syria 220V 50Hz E, F & N 欧洲规格双脚圆型/ 意大利规三脚圆型黎巴嫩/ Lebanon 220V 50Hz E 欧洲规格双脚圆型科威特/ Kuwait 220-240V 50Hz E & I 欧洲规格双脚圆型/ 英规格三脚扁型以色列/ Israel 220-240V 50Hz E & P 欧洲规格双脚圆型/ 以色列规格巴林/ Bahrain 220V 50Hz I & K 英规三脚扁型/ 英规三脚扁型杜拜/ Dubai 220V 50Hz G 欧洲规格双脚圆型土耳其/ Turkey 220V 50Hz E & F 欧洲规格双脚圆型北美地区国名(中文/ 英文) 电压频率插头型式说明美国/ United States 120V 60 A & B 两脚扁型/ 两脚扁+圆型接地脚加拿大/ Canada 110V 60 A & B 两脚扁型/ 两脚扁+圆型接地脚中南美地区国名(中文/ 英文) 电压频率插头型式说明墨西哥/ Mexico 127V 60 A & B 两脚扁型/两脚扁+圆型接地脚瓜地马拉/ Nicaragua 110V 60 A & B 两脚扁型/两脚扁+圆型接地脚萨尔瓦多/ El Salvador 110V 60 A & B 两脚扁型/两脚扁+圆型接地脚宏都拉斯/ Honduras 110V 60 A & B 两脚扁型/两脚扁+圆型接地脚尼加拉瓜/ Nicaragua 110V 60 A & B 两脚扁型/两脚扁+圆型接地脚哥斯达黎加/ Costa Rica 110-120V 60 A & B 两脚扁型/两脚扁+圆型接地脚巴拿马/ Panama 120V 60 A & B 两脚扁型/两脚扁+圆型接地脚海地/ Haiti 110-120V 60 A & B 两脚扁型/两脚扁+圆型接地脚多米尼加/ Dominican Rep. 110V 60 A & B 两脚扁型/两脚扁+圆型接地脚哥伦比亚/ Columbia 115V 60 A & B 两脚扁型/两脚扁+圆型接地脚委内瑞拉/ Venezuela 110V 60 A & B 两脚扁型/两脚扁+圆型接地脚厄瓜多/ Ecuador 110V 60 A & B 两脚扁型/两脚扁+圆型接地脚巴西/ Brazil 110V / 220V 60Hz / 50HzA, B & E 美规两脚扁型(+接地脚) / 欧规格双脚圆型秘鲁/ Peru 110V / 220V 60Hz / 50HzA, B & E 美规两脚扁型(+接地脚) / 欧规格双脚圆型玻利维亚/ Bolivia 110V / 220V 60Hz / 50HzA, B & E 美规两脚扁型(+接地脚) /欧规格双脚圆型巴拉圭/ Paraguay 220V 50Hz E 欧洲规格双脚圆型乌拉圭/ Uruguay 220V 50Hz E 三孔型阿根廷/ Argentina 220V 50Hz C & D 八字型智利/ Chile 220V 50Hz E & N 欧规格双脚圆型/ 意大利规三脚圆型欧洲地区国名(中文/ 英文) 电压频率插头型式说明意大利/ Italy 220-230V 50Hz E & N 意大利规格三脚圆型/ 欧规格双脚圆型奥地利/ Austria 220V 50Hz E, F & G 欧洲规格双脚圆型波兰/ Poland 220V 50Hz E, F & G 欧洲规格双脚圆型匈牙利/ Hungary 220V 50Hz F & G 欧洲规格双脚圆型希腊/ Greece 220V 50Hz E, F & G 欧洲规格双脚圆型比利时/ Belgium 220V 50Hz E, F & G 欧洲规格双脚圆型荷兰/ Netherlands 220V 50Hz E, F & G 欧洲规格双脚圆型卢森堡/ Luxembourg 220V 50Hz E, F & G 欧洲规格双脚圆型英国/ United Kingdom 220-240V 50Hz I 英规三脚扁型爱尔兰/ Ireland 220V 50Hz I 英规三脚扁型法国/ France 220V 50Hz E, F & G 欧洲规格双脚圆型瑞士/ Switzerland 220-224V 50Hz E & M 瑞士规格三脚圆型/ 欧洲规格双脚圆型西班牙/ Spain 220V 50Hz E, F & G 欧洲规格双脚圆型葡萄牙/ Portugal 220V 50Hz E, F & G 欧洲规格双脚圆型德国/ Germany 220V 50Hz E, F & G 欧洲规格双脚圆型挪威/ Norway 220V 50Hz E, F & G 欧洲规格双脚圆型荷兰/ Finland 220V 50Hz E, F & G 欧洲规格双脚圆型丹麦/ Denmark 220V 50Hz E, F, G & O丹麦规格三脚圆型/ 欧洲规格双脚圆型瑞典/ Sweden 220V 50Hz E, F & G 欧洲规格双脚圆型拉脱维亚/ Latvia 220-240V 50Hz E & F 八字型/ 欧洲规格双脚圆型斯洛伐克/ Slovak Rep. 220V 50Hz E, F & G 欧洲规格双脚圆型非洲地区国名(中文/ 英文) 电压频率插头型式说明南非/ Rep. South Africa 220V 50Hz K & L 三脚圆型马拉威/ Malawi 240V 50Hz I 英规三脚扁型布吉纳法索/ Burkina Faso 220V 50Hz E & F 欧洲规格双脚圆型史瓦济兰/ Swaziland 220V 50Hz I 英规三脚扁型塞内加尔/ Senegal 220V 50Hz E, F & G 欧洲规格双脚圆型甘比亚/ Gambia 220V 50Hz I 英规三脚扁型查德/ Chad 220-250V 50Hz F, G & L 欧洲规格双脚圆型/ 英规三脚扁型加彭/ Gabon 220V 50Hz G 欧洲规格双脚圆型迦纳/ Ghana 220V 50Hz E, I & K 欧规双脚圆型/ 英规三脚扁型赤道几内亚/ Equatorial Guinea 220V 50Hz E & F 欧规双脚圆型奈及利亚/ Nigeria 230V 50Hz I 英规三脚扁型喀麦隆/ Cameroon 220V 50Hz E, F & G 欧洲规格双脚圆型。

国际插头标准

国际插头标准

各国电压和开关插座目前世界各国室内用电所使用的电压共有三种,分别为100V、110~130V与220~230V三个类型。

100V、110~130V被归类低压比如船上的电压,因此它的设备都是按照这样的低电压设计的;220~230V则称为高压,其中包括了中国的220伏及英国的230伏.世界各各国电压概况100V :日本、北韩110~130V:台湾、美国、加拿大、巴拿马、古巴、黎巴嫩、墨西哥220~230V :英国、德国、法国、中国、新加坡、香港(200V)、义大利、西班牙、希腊、奥地利、荷兰、菲律、泰国、挪威、新加坡、印度、纽西兰、澳洲国标插头在中国、澳大利亚、新西兰、阿根廷使用,特征是三个扁头。

美标插头在美国、加拿大、日本、巴西、菲律宾、泰国等国家和台湾使用,特征是一圆两扁。

英标插头在香港和英国、印度、巴基斯坦、新加坡、马来西亚、越南、印度尼西亚、马尔代夫、卡塔尔等国家和地区使用,特征是三个方头。

欧标(德标)插头在德国、法国、荷兰、丹麦、芬兰、挪威、波兰、葡萄牙、奥地利、比利时、匈牙利、西班牙、瑞典等欧盟国家及韩国、俄罗斯等国家使用,特征是两个圆头。

南非标插头主要是在南非、印度、俄罗斯使用,特征是三个圆头。

还有意大利标准(意标)插头、瑞士标准(瑞士标)插头等。

出国转换插头也存在同一个国家或地区使用多种标准的情形。

220V 。

大部分国家的电压与我国一样,是220V,某些国家频率是60Hz,另外,还有110V的。

附录:世界各国电压亚太地区国别或地区电压插座供电情形备注日本100V 双孔扁型供电稳定韩国220V 双孔圆型供电正常香港地区220V 三孔扁型供电正常澳门地区220V 三孔型供电稳定,甚少停电越南220V 双孔圆型及扁型供电尚属稳定,有间歇性停电泰国220V 双孔圆型及扁型供电尚属良好马来西亚220-240V 三孔型供电尚属正常新加坡220V 三孔扁型供电稳定菲律宾220V 双孔扁型及三孔型供电尚稳定,偶有停电印度尼西亚220V 双孔圆型供电尚稳定,偶有断电情形文莱220-240V 三孔型供电不稳定,常有故障及停电情形印度240V 圆孔三插式(5及15安培二种) 供电不稳定,常停电各项电器均需配置稳压器澳大利亚240V 60HZ 三孔八字型电压稳定,无停电之虑电视、录放机为PAL 系统纽西兰220V 八字型供电稳定巴布亚纽几内亚240V 三孔扁型供电十分不稳定斐济220V 三孔型供电尚称稳定诺鲁220V 三孔扁型偶有停电、电压不稳精密电器宜配置稳压器索罗门220-250V 三孔扁型供电不稳定吐瓦鲁220-240V 三孔八字型供电尚属正常吉里巴斯240V 三孔扁型电源供应不稳定亚西地区国别或地区电压插座供电情形备注俄罗斯220V 50-60hz 双孔圆型供电尚称良好,惟电压不稳白俄罗斯220V 50-60hz 双孔圆型供电尚称良好,惟电压不稳沙特阿拉伯110及220V 双孔扁型及圆型供电稳定冷气机三孔扁型插座或直接电源接线约旦220V 双孔圆型及扁型或三孔供电尚称稳定使用插座转换器伊拉克220V 双孔圆型及扁型或三孔供电尚称稳定使用插座转换器叙利亚220V 双孔圆型及扁型或三孔供电尚称稳定使用插座转换器黎巴嫩220V 双孔圆型及扁型或三孔供电尚称稳定使用插座转换器科威特220-240V 三孔型(含地线) 供电尚称稳定以色列220-240V 50Mhz 双孔圆型供电尚称稳定,有间歇性短暂停电巴林220V 三孔型供电尚称稳定阿曼220V 三孔型电源供应稳定,甚少停电杜拜220V 三孔扁型供电稳定土耳其220V 双孔圆型供电良好(首都地区)北美地区国别或地区电压插座供电情形备注美国120V AC接地三线式供电良好加拿大110V 双孔扁型供电良好中南美地区国别或地区电压插座供电情形备注墨西哥110V 双孔扁型供电尚称良好危地马拉110V 双孔型供电尚佳,偶有断电贝里斯110V (少数220V) 双孔及三孔型供电不足萨尔瓦多110V 双孔型供电稳定雨季时有停电情形宏都拉斯110V (少数220V) 双孔扁型(少数三孔型) 供电不足、时有限电供电普及率为43%尼加拉瓜110V 双孔及三孔(接地线) 经常停电须自备柴油发电机哥斯达黎加110-120V 二端不同大小之双孔式常有小规模停电电流不稳,须使用稳压器巴拿马110V 50-60HZ 双孔型供电尚称稳定可另接220V及使用三孔插座海地110V 三孔型供电不足,电压不稳每日供电仅三、四小时多米尼加110V 双孔型电压不稳,供电不足须自备发电机供电(冷气机为220V)格瑞那达220V (110V) 三孔型(双孔型) 供电稳定偶有停电每次停电约半个至四小时千里达220V (110V) 三孔型(双孔型) 供电稳定偶有停电每次停电约半个至四小时圣文森220V/50HZ 双孔圆型供电稳定圣露西亚220V/50HZ 双孔圆型供电稳定巴贝多110V 双孔圆型供电稳定马丁尼克220V/50HZ 双孔圆型供电稳定圣克里斯多福220V 三孔型供电尚称稳定,偶有跳电、停电情形每次停电约一至二小时多米尼克220V 三孔型供电不稳,偶有停电哥伦比亚110-120V (旧式大楼150V) 三角型经常停电电器用品须装稳压器委内瑞拉110V 60HZ 双孔型供电尚称稳定,偶有停电厄瓜多110V (110-120V) 双孔型供电稳定,偶有停电每年月枯\水期分区轮流停电(五-十月每日停电3-4小时)巴西220V 三叉式供电不稳定圣保罗110V 双孔型供电稳定秘鲁220V 双孔型供电稳定,偶有停电玻利维亚110V及120V二种双孔扁型供电正常巴拉圭220V 双孔圆型供电稳定乌拉圭220V 50HZ 三孔型供电稳定,偶有停电阿根廷220V 50HZ 双孔圆型及三孔型供电稳定,偶有停电电压不稳定智利220V 50hz 三孔圆型供电良好欧洲地区国别或地区电压插座供电情形备注教廷220V 双孔及三孔型供电良好意大利220-230V 双孔及三孔型供电良好奥地利220V,50hz 双孔圆型供电良好捷克220V 双孔附圆柱接地极供电尚称稳定,偶有停电波兰220V 双孔圆型供电良好匈牙利220V 双孔圆型供电良好希腊220V 双孔圆型供电良好比利时220v 50/60hz 双孔及三孔圆型供电良好荷兰220V 50hz 双孔圆型供电稳定卢森堡220V 双孔圆型供电稳定英国220-240V 三孔扁型供电稳定爱尔兰220V 三孔型供电稳定法国220V 圆型带地线供电良好瑞士220-224V 三孔圆型供电良好西班牙220V 双孔圆型供电良好葡萄牙220V 50hz 双孔圆型供电稳定德国220V,50hz 圆型供电良好挪威220-230V 双孔圆型供电稳定芬兰230V 双孔圆型供电良好丹麦220V 双孔圆型供电稳定瑞典220V 三孔及二孔圆型供电良好拉脱维亚220-240V 双孔圆型供电尚属良好斯洛伐克220V 双孔圆形供电稳定电视录放机为PAL系统非洲地区国别或地区电压插座供电情形备注南非220V 50HZ 三孔圆型供电稳定雷电多,电器易遭电击而受损模里西斯240V 三孔型马拉威240V 三孔扁型式电力供应不足电器产品须装稳压器布吉纳法索220V 50hz 双孔扁圆型供电不足,电压不稳经常停电宜备稳压器史瓦济兰220V 三孔圆型平时正常,每年九月至翌年三月断电频繁,夜晚更严重赖比瑞亚110及220V 双孔扁型仅间歇性供电,主赖自备发电机,供电极不稳定塞内加尔220V 50hz 双孔圆型经常停电计算机、音响最好装置不断电系统维德角220V 双孔型附地线(欧规) 供电稍差须装置稳压器甘比亚220V 英式或欧陆式二种,以英式者主经常停电数小时至半日查德220-250V 双孔型,直径4.7 供电甚差,经常停电法国电力系统规格圣多美普林西比220V 双孔型附地线(欧规) 圣多美供电甚差须装置稳压器加彭220V 双孔型附地线(欧规) 供电尚属正常须装置稳压器迦纳220V 三孔扁型供电情形甚差电器用品需备稳压器赤道几内亚220V 三孔扁型供电情形甚差电器用品需备稳压器奈及利亚220V 三孔扁型供电情形甚差,须自备发电机电器用品需备稳压器喀麦隆 220V 三孔扁型供电稍差须装置稳压器。

巴西插头标准新规2011-6-21 NBR 14136

巴西插头标准新规2011-6-21 NBR 14136

Portaria n.º 271, de 21 de junho de 2011O PRESIDENTE DO INSTITUTO NACIONAL DE METROLOGIA, NORMALIZAÇÃO E QUALIDADE INDUSTRIAL - INMETRO, em exercício, no uso de suas atribuições, conferidas no § 3º do artigo 4º da Lei n.º 5.966, de 11 de dezembro de 1973, no inciso I do artigo 3º da Lei n.º 9.933, de 20 de dezembro de 1999, e no inciso V do artigo 18 da Estrutura Regimental da Autarquia, aprovada pelo Decreto n° 6.275, de 28 de novembro de 2007;Considerando a alínea f do subitem 4.2 do Termo de Referência do Sistema Brasileiro de Avaliação da Conformidade, aprovado pela Resolução Conmetro nº 04, de 02 de dezembro de 2002, que atribui ao Inmetro a competência para estabelecer as diretrizes e critérios para a atividade de avaliação da conformidade;Considerando o artigo 1º da Resolução Conmetro n.º 11, de 20 de dezembro de 2006, que determina o atendimento, pelas empresas fabricantes e importadoras de plugues e tomadas, às especificações da norma ABNT NBR 14136 e configura observância ao estabelecido nesta Resolução e em Portaria do Inmetro, tornando compulsória a certificação de plugues e tomadas;Considerando a Portaria Inmetro nº 85, de 03 de abril de 2006, que aprova, para observância compulsória, o Regulamento de Avaliação da Conformidade para Plugues e Tomadas para uso Doméstico e Análogo e dá outras providências;Considerando a Portaria Inmetro nº 324, de 21 de agosto de 2007, que aprova o Regulamento de Avaliação da Conformidade para Adaptadores de Plugues e Tomadas;Considerando a Portaria Inmetro nº 251, de 15 de setembro de 2009, que estabelece os projetos básicos para as possíveis configurações de adaptadores reversos de plugues e tomadas;Considerando a necessidade de adoção de novas medidas que visem a esclarecer aspectos construtivos obrigatórios para o padrão de plugues e tomadas, conforme ABNT NBR 14136, resolve:Art. 1º Determinar que as tomadas fixas ou móveis de 3 (três) contatos, desmontáveis ou não desmontáveis, deverão ter marcados nos bornes neutro e terra os símbolos correspondentes, respectivamente N e .Art. 2° Estabelecer que os adaptadores e as tomadas fixas ou móveis de 2 (dois) ou 3 (três) contatos, desmontáveis ou não desmontáveis, comercializados em todo o território nacional, deverão ser construídos de forma a não permitir a desconfiguração ou a descaracterização do padrão conforme a norma ABNT NBR 14136, inclusive nos casos em que seja necessário o uso de ferramentas para este fim.Parágrafo Único – A determinação constante no caput deverá ser estendida para os conjuntos constituídos por plugue, tomada múltipla e cordão prolongador (comumente denominado extensão).Art. 3° Estabelecer que os adaptadores e as tomadas fixas ou móveis de 2 (dois) ou 3 (três) contatos, desmontáveis ou não desmontáveis, comercializados em todo o território nacional, não deverão apresentar qualquer dispositivo que anule a funcionalidade do pino de aterramento.Parágrafo Único –A determinação constante no caput deverá ser estendida para cordões conectores e para os conjuntos constituídos por plugue, tomada múltipla e cordão prolongador (comumente denominado extensão).Art. 4° Os plugues de dois ou três pinos, as tomadas fixas ou móveis e os adaptadores deverão ter estampadas em seu corpo as seguintes indicações:a) o nome, a marca ou o logotipo do fabricante;b) a tensão a que se destinam em Volt (V);c) a potência em Watt (W) ou a corrente nominal em Ampère (A);d) país de fabricação; e oe) selo de identificação da conformidade.Art. 5° Estabelecer que a partir de 12 (doze) meses após a publicação desta Portaria, a fabricação e a importação das tomadas fixas ou móveis de 2 (dois) ou 3 (três) contatos, desmontáveis ou não desmontáveis, deverão atender aos requisitos estabelecidos nos artigos 1º e 2º desta Portaria.Parágrafo Único –Dezoito meses após a publicação desta Portaria, os produtos mencionados no caput somente deverão ser comercializados, por fabricantes e importadores, em conformidade com os requisitos estabelecidos nos artigos 1º e 2º desta Portaria.Art. 6º Estabelecer que a partir de 24 (vinte e quatro) meses após a publicação desta Portaria, os produtos mencionados no artigo anterior somente deverão ser comercializados, por atacadistas e varejistas, em conformidade com os requisitos estabelecidos nos artigos 1º e 2º desta Portaria.Parágrafo Único - A determinação contida no caput não é aplicável aos fabricantes e importadores, que deverão observar os prazos fixados no artigo anterior.Art. 7º Determinar que para as tomadas fixas ou móveis de 2 (dois) ou 3 (três) contatos, desmontáveis ou não desmontáveis, os demais artigos desta Portaria serão de cumprimento obrigatório a partir da data de sua publicação.Art. 8º Estabelecer que para os adaptadores de plugues e tomadas, os artigos pertinentes expressos nesta Portaria serão de cumprimento obrigatório a partir da data de sua publicação.Art. 9º Determinar que, para fins de certificação, quando da aplicação da Portaria Inmetro nº 85, de 03 de abril de 2006, da Portaria Inmetro nº 324, de 21 de agosto de 2007, e da Portaria Inmetro nº 251, de 15 de setembro de 2009, serão atendidos os artigos 1º, 2º, 3º e 4º desta Portaria.Art. 10 Cientificar que a fiscalização do cumprimento das disposições contidas nesta Portaria, em todo o território nacional, ficará a cargo do Inmetro e das entidades de direito público a ele vinculadas por convênio de delegação.Parágrafo Único – A fiscalização observará os prazos estabelecidos nos artigos 5º, 6º, 7º e 8º desta Portaria.Art. 11 Esta Portaria entrará em vigor na data de sua publicação no Diário Oficial da União.JOÃO ALZIRO HERZ DA JORNADA。

不同国家采用的民用交流电电压标准

不同国家采用的民用交流电电压标准

220V和110V是不同国家采用的民用交流电电压标准。

我用的是220V/50Hz,美国和日本是110V/60Hz,从理论角度来说,电压越高,线路上的损耗就越小,而电压越低越安全,如果超导体能走出实验室,我们都用12V供电就可以了。

各个国家(地区)电压与频率比较国家电压/ 频率大溪地(Tahiti) 127V/60Hz中国(China) 220V/50Hz巴布亚新几亚(Papua New Guinea) 240V/50Hz巴林(Bahrain) 100V/60Hz; 230V/50Hz日本(Japan) 220V/60Hz北(North Korea) 220V/60Hz卡达(Qatar) 240V/50Hz(Taiwan) 110V/60Hz沙巴(Saba) 240V/50Hz尼加拉瓜(Nicaragua) 127V/50Hz; 220V/60Hz危地马拉(Guatemala) 115V/60Hz沙特阿拉伯(Saudi Arabia) 127V/50Hz; 220V/60Hz沙特阿拉伯:阿布达比(Abu Dhabi) 240V/50Hz文莱(Brunei) 240V/50Hz孟加拉国国(Bangladesh) 230V/50Hz所罗门(Solomon Islands) 240V/50Hz阿曼(Oman) 240V/50Hz阿富汗(Afghanistan) 220V/50Hz南(South Korea) 110V/60Hz柬埔寨(Cambodia) 120V/50Hz; 208V/50Hz科威特(Kuwait) 240V/50Hz埃与(Egypt) 220V/50Hz马来西亚(Malaysia) 240V/50Hz斐济群岛(Fiji Islands) 240V/50Hz斯里兰卡(Sri Lanka) 230V/50Hz菲律宾(Philippines) 110V/60Hz越南(Vietnam) 120V/50Hz塞普路斯(Cyprus) 240V/50Hz模里西斯(Mauritius) 230V/50Hz缅甸(Burma) 230V/50Hz黎巴嫩(Lebanon) 110, 220V/50Hz维埃社会主义国联盟(USSR:Union of Soviet Socialist Republics) 127V/50Hz;220V/50Hz千里达& 托贝哥(Trinidad & Tobago) 120V/60Hz厄瓜多尔(Ecuador) 110-120V/60Hz巴西(Brazil) 110-220V/60Hz巴贝多(Barbados) 115V/50Hz巴拉圭(Paraguay) 220V/50Hz巴哈马(Bahamas) 115V/60Hz牙买加(Jamaica) 110V/50Hz加拿大(Canada) 120V/60Hz古巴(Cuba) 120V/60Hz尼加拉瓜(Nicaragua) 120V/60Hz瓜地马拉(Guatemala) 115V/60Hz多米尼加国(Dominican Rep.) 110V/60Hz 安地卡(Antigua) 220V/50Hz安圭拉岛(Anguilla) 220V/50Hz百慕达(Bermuda) 115V/60Hz洪都拉斯(Honduras) 110V/60Hz贝里斯(Belize) 110V/60Hz委瑞拉(Venezuela) 120V/60Hz波多黎各(Puerto Rico) 120V/60Hz 法属圭亚那(French Guiana) 220V/50Hz 阿根廷(Argentina) 220V/50Hz玻利维亚(Bolivia) 110V/50Hz美国(America) 120V/60Hz哥伦比亚(Colombia) 110-120V/60Hz哥斯达黎加(Costa Rica) 120V/60Hz格瑞那达(Guadeloupe) 220V/50Hz格瑞那达(Grenada) 220V/50Hz海地(Haiti) 110V/60Hz乌拉圭(Uruguay) 220V/50Hz秘鲁(Peru) 220V/60Hz马丁尼克(Martinique) 220V/50Hz荷属安第列斯群岛(Neth. Antilles) 120V/50Hz 处女岛(Virgin Islands) 120V/60Hz智利(Chile) 220V/50Hz圣文森市(St. Vincent) 220V/50Hz圣露西亚(St. Lucia) 240V/50Hz福克兰群岛(Falkland Islands) 230V/50Hz蒙特色纳岛(Monteserrat) 220V/60Hz盖亚那(Guyana) 110V/60Hz;240V/50Hz 墨西哥(Mexico) 120V/60Hz萨尔瓦多(El Salvador) 115V/60Hz关岛(Guam) 120V/60Hz利南(Surinam) 110V/60Hz沙巴岛(Saba) 240V/50Hz玻利维亚(Bolivia) 115V/50Hz开曼群岛(Cayman Island) 120V/60Hz丹麦(Denmark) 220V/50Hz比利时(Belgium) 220V/50Hz北爱尔兰(Ireland Northern) 220V/50Hz 冰岛(Iceland) 220V/50Hz匈牙利(Hungary) 220V/50Hz西班牙(Spain) 127V/50Hz; 220V/50Hz 希腊(Greece) 220V/50Hz波兰(Poland) 220V/50Hz法国(France) 220V/50Hz直布罗陀(Gibraltar) 240V/50Hz芬兰(Finland) 220V/50Hz保加利亚(Bulgaria) 220V/50Hz南斯拉夫(Yugoslavia) 220V/50Hz英国(United Kingdom) 240V/50Hz挪威(Norway) 230V/50Hz马尔他(Malta) 240V/50Hz 捷克国(Czech Republic) 220V/50Hz 荷兰(Netherlands) 220V/50Hz斯洛伐克(Slovakia) 220V/50Hz奥地利(Austria) 220V/50Hz爱尔兰国(Ireland of Rep.) 220V/50Hz 意大利(Italy) 220V/50Hz葡萄牙(Portugal) 220V/50Hz斯里兰卡(Sri Lanka) 220V/50Hz德国(Germany) 230V/50Hz摩纳哥(Monaco) 127V/50Hz; 220V/50Hz 卢森堡(Luxembourg) 220V/50Hz罗马尼亚(Romania) 220V/50Hz澳洲((Australia) 240, 250V/50Hz纽西兰(New Zealand) 230~240V/50Hz 史瓦济兰(Swaziland) 230V/50Hz哪崛(Niger) 220V/50Hz多哥(Togo) 220V/50Hz安哥拉(Angola) 220V/50Hz埃塞俄比亚(Ethiopia) 220V/50Hz利比亚(Libya) 115V/50Hz坦尚尼亚(Tanzania) 230V/50Hz奈与利亚(Nigeria) 220~230V/50Hz 尚比亚(Zambia) 230V/50Hz波扎那(Botswana) 220V/50Hz肯亚(Kenya) 240V/50Hz阿尔与利亚?/FONT>(Algeria) 220V/50Hz 南非(South Africa) 220V/50Hz查德Chad) 220V/50Hz突尼西亚(Tunisia) 220V/50Hz迦纳(Ghana) 40V/50Hz乌干达(Uganda) 240V/50Hz索马里V/Hz马利(Mali) 127V/50Hz; 220V/50Hz马拉加国(Malagassy Rep.) 127V/50Hz; 220V/50Hz 马拉威(Malawi) 230V/50Hz喀麦隆(Cameroon) 220V/50Hz象牙海岸(Ivory Coast) 220V/50Hz塞加尔(Senegal) 110V/50Hz塞席尔群岛(Seychelles) 240V/50Hz狮子山国(Sierra Leone) 230V/50Hz达荷美国(Dahomey) 220V/50Hz摩洛哥(Morocco) 230V/50Hz卢旺达(Rwanda) 220V/50Hz赖比瑞亚(Liberia) 120V/60Hz莱索托(Lesotho) 220V/50Hz萨伊(Zaire) 220V/50Hz罗德西亚(Rhodesia) 225V/50Hz丹(Sudan) 240V/50Hz欧洲各国电压与插座转自背包客栈前几天要去买万用插头,发现原来有这么多种,剎时间不知要买哪一种因为有些产品已经将万用和变压器或整流器做在一起了以下就容我对万用插头、变压器和整流器作一些简单的说明让和相同困扰的朋友能清楚了解自己需要的是哪一种万用插头:由於各国的插座不尽相同,而的电器到国外使用,插座和插头必须要能吻合,因此万用插头的功能就是改变插头的形状,使之符合插形状,因此万用插头不负责调整电压(当然市面上也有将其和变压器或整流器做在一起)。

世界主要国家插座标准(带图示)

世界主要国家插座标准(带图示)

各国频率、电压、插头形式一览表英 文 中 文 HZ Voltage Plug 英 文 中 文 HZ Voltage Plug Algeria 阿尔及利亚 50 127,220 EP,EP3,BP Korea 韩国 60 100 EP Argentina 阿根廷 50 220 EP2,BP Kuwait 科威特 50 240 CP2 Australia 澳洲 50 240 AP3 Lebanon 黎巴嫩 50 110 CP2 Austria 奥地利 50 220 CP2 Libya 利比亚 50 125 BP3 Belgium 比利时 50 127,220 BP3 Luxembourg 卢森堡 50 110,220 CP2 Bolivia 波利维亚 50,60 220 EP,EP3 Malaysia 马来西亚 50 230,240 BP3,BP Brazil 巴西 60 220 CP2 Mexico 墨西哥 60,50 120 EP Bulgaria 保加利亚 50 220 CP2 Monaco 摩纳哥 50 127,220 CP2 Burma 缅甸 50 230 CP2 Netherlands 荷兰 50 220 GP Canada 加拿大 60 120 EP,BP New Zealand 新西兰 50 230 AP3 Chile 智利 50 220 CP2 Nicaragua 尼加拉瓜 60 120 EP Colombia 哥伦比亚 60 115 EP Nigeria 尼日利亚 50 230 BP3,BP2 Congo 刚果 50 220 CP2 Norway 挪威 50 230 CP2 Costa Rica 哥斯达黎加 60 110 EP Okinawa 冲绳 60 100 EP Cuba 古巴 60 115,120 CP2 Pakistan 巴基斯坦 50 220 BP2,BP3 Czechoslovaks捷克 50 110,220 BP3 Panama 巴拿马 60 120 EP Dubai 迪拜 50 220 BP2 Poland 波兰 50 220 CP2 Ecuador 厄瓜多尔 60 110,120,127 EP Portugal 葡萄牙 50 220 CP2,BP3 EI Salvador 萨尔瓦多 60 110 EP Romania 罗马尼亚 42,50 220 CP2 England 英国 50 240 BP3,BP Saipan 塞班岛 60 110 EP Finland 芬兰 50 220 CP2 Saudi Arabia 沙特地阿拉伯 50,60 120,220 CP2,EP France 法国 50 220 CP2 Sierra Leone 狮子山 50 230 CP2,BP3 Germany 德国 50 220 GP South Africa 南非 50 230 BP3 Ghana 加纳 50 220 BP2 Spain 西班牙 50 220 CP2,EP Greece 希腊 50 220 BP3 Sudan 苏丹 50 240 BP3,BP2 Guam 关岛 60 110 EP Surinam 苏里南 60 127 CP2 Guatemala 危地马拉 60 220 EP Sweden 瑞典 50 120,127,220 CP2 Haiti 海地 60,50 115 EP Switzerland 瑞士 50 220 CP2 Hawaii 夏威夷 60 120 EP Syria 叙利亚 50 110 CP2 Honduras 洪都拉斯 60 110 ,220 EP Tanzania 坦桑尼亚 50 230 BP3,BP英 文 中 文 HZ Voltage Plug 英 文 中 文 HZ Voltage Plug Hong Kong 香港 50 220 BP3 Denmark 丹麦 50 220 CP2 Peru 秘鲁 60 110,220 EP,CP2 Dominica 多米尼加 60 115 EP Philippines 菲律宾 60 220 BP3,EP India 印度 50 230 BP2,BP3 Thailand 泰国 50 220 BP2 Hungary 匈牙利 40,50 220 CP2 Tunisia 突尼斯 60 230 CP2 Turkey 土耳其 50 110,220 CP2 Indonesia 印尼 50 110 BP3 Uganda 乌干达 50 230 BP2 Iran 伊朗 50 220 CP2 United Arab 阿拉伯联邦 50 110,220 EP Iraq 伊拉克 50 220 CP2 U.S.A 美国 60 115,120 EP Jamaica 牙买加 50,60 110 EP,CP2 U.S.S.R 苏联 50 110,220 CP2 Jordan 约旦 50 220 CP2 Viet- -Nam 越南 60,50 120 EP Japan 日本 50,60 100 EP Yugoslavia 南斯拉夫 50 220 CP2 Israel 以色列 50 230 CP2 Egypt 埃及 50 220 BP2 Morocco 摩洛哥 50 110,220 CP2 Cyprus 塞浦路斯 50 220 BP2 Kenya 肯尼亚 50 230 BP3,BP Paraguay 巴拉圭 50 220 CP2CP Continental plug 欧式插头 G.P German plug 德式插头 E.P Edison plug 美式插头 B.P British Standard plug 英式插头 A.P Australia plug 澳式插头EP 两脚扁插头(目前国内用) AP3 三脚扁插头CP2 两脚圆插头(4mm) BP 三脚扁钝插头BP2 两脚圆插头(5mm) GP 两脚圆插头(4.8mm)BP3 三脚圆插头 EP3 一圆二扁插头简图主要采用国家中国美国日本美国欧洲意大利欧洲欧洲丹麦瑞士简图主要采用国家意大利英国南非英国澳大利亚以色列澳大利亚中国阿根廷。

世界各国转换插头规格列表

世界各国转换插头规格列表

世界各国转换插头规格列表A澳大利亚插头 230 澳洲转换插头阿富汗插头 220 德国/法国转换插头阿根廷插头 220 德国/法国转换插头阿拉伯联合酋长国插头 220 欧洲/英国转换插头埃及插头 220 德国/法国转换插头埃塞俄比亚插头 230 瑞士转换插头爱尔兰插头 230 德国/法国转换插头安哥拉插头 220 德国/法国转换插头安圭拉岛插头 110 日本转换插头安提瓜岛插头 230 美国转换插头奥地利插头 230 德国/法国转换插头B巴巴多斯岛插头 115 美国转换插头巴布亚新几内亚插头 240 国标/澳洲转换插头巴哈马群岛插头 120 美国转换插头巴基斯坦插头 230 英国转换插头巴拉圭插头 220 德国/法国转换插头巴利阿里群岛插头 220 德国/法国转换插头巴林群岛插头 230 英国转换插头巴拿马插头 110 美国转换插头巴西插头 220 美国转换插头百慕大群岛插头 120 美国转换插头保加利亚插头 230 德国/法国转换插头贝宁湾插头 220 德国/法国转换插头比利时插头 230 德国/法国转换插头冰岛插头 220 德国/法国转换插头波多黎各插头 120 美国转换插头波兰插头 220 德国/法国转换插头波斯尼亚插头 220 德国/法国转换插头玻利维亚插头 220 德国/法国转换插头伯利兹城插头 220 美国转换插头博茨瓦纳插头 231 英国转换插头D丹麦插头 220 德国/法国转换插头德国插头 230 德国/法国转换插头东帝汶插头 220 德国/法国转换插头多哥插头 220 德国/法国转换插头多米尼加插头 230 英国转换插头多米尼加共和国插头 110 日本转换插头E俄罗斯插头 220 德国/法国转换插头厄瓜多尔插头 120 美国转换插头厄立特里亚插头 230 德国/法国转换插头F法国插头 230 德国/法国转换插头法罗群岛插头 220 德国/法国转换插头菲律宾插头 220 美国转换插头芬兰插头 230 德国/法国转换插头佛得角插头 220 德国/法国转换插头福克兰群岛插头 240G刚果插头 230 德国/法国转换插头哥伦比亚插头 110 美国转换插头哥斯达黎加插头 120 美国转换插头古巴插头 110/220 德国/法国转换插头瓜德罗普岛插头 230 德国/法国转换插头关岛插头 120 美国转换插头圭亚那插头 240 美国转换插头H哈萨克斯坦插头 220 德国/法国转换插头海地插头 110 美国转换插头韩国插头 220 德国/法国转换插头荷兰插头 230 德国/法国转换插头洪都拉斯插头 110 美国转换插头怀特岛插头 240 德国/法国转换插头J加拿大插头 120 美国转换插头加纳插头 230 英国转换插头加蓬插头 220 欧洲转换插头加沙插头 230柬埔寨插头 230 德国/法国转换插头K捷克斯洛伐克插头 230 德国/法国转换插头津巴布韦插头 220 英国转换插头喀麦隆插头 220 德国/法国转换插头卡塔尔插头 240 英国转换插头开曼群岛插头 120 美国转换插头科摩罗插头 220 德国/法国转换插头科威特插头 240 德国/法国转换插头克罗地亚插头 230 德国/法国转换插头肯尼亚插头 240 英国转换插头拉脱维亚插头 220 德国/法国转换插头L莱索托插头 220老挝国插头 230 美国转换插头黎巴嫩插头 230 美国转换插头立陶宛插头 220 德国/法国转换插头利比里亚插头 120 美国转换插头利比亚插头 127列支敦士登的插头 230 瑞士转换插头卢森堡插头 220 德国/法国转换插头卢旺达插头 230 德国/法国转换插头罗马尼亚插头 230 德国/法国转换插头马达加斯加岛插头 220 德国/法国转换插头M马尔代夫插头 230 英国转换插头马耳他插头 240 英国转换插头马拉维插头 230 英国转换插头马来群岛插头 240 英国转换插头马里插头 220 德国/法国转换插头马其顿王国插头 220 德国/法国转换插头马提尼克岛插头 220 德国/法国转换插头毛里求斯插头 230 德国/法国转换插头毛利塔尼亚插头 220 德国/法国转换插头美国插头 120 美国转换插头蒙古插头 230 德国/法国转换插头蒙特塞拉特岛插头 230 美国转换插头孟加拉国插头 220 德国/法国转换插头秘鲁插头 220 美国转换插头密克罗尼西亚插头 120 美国转换插头缅甸插头 230 德国/法国转换插头摩洛哥插头 220 德国/法国转换插头摩纳哥插头 220 德国/法国转换插头莫桑比克插头 220 德国/法国转换插头墨西哥插头 127 美国转换插头纳米比亚插头 220N南非插头 220/230 南非转换插头南斯拉夫插头 220 德国/法国转换插头瑙鲁插头 240 国标/澳洲转换插头尼加拉瓜插头 120 日本转换插头尼日尔插头 220 德国/法国转换插头尼日利亚插头 240 美国/英标转换插头挪威插头 220 德国/法国转换插头P葡萄牙插头 220 德国/法国转换插头R日本插头 100 日本转换插头瑞典插头 220 德国/法国转换插头瑞士插头 230 瑞士转换插头塞浦路斯插头 240 英国转换插头塞舌尔插头 240 英国转换插头沙特阿拉伯插头 127/220 美国/欧洲/英国转换插头圣路易斯插头 230 英国转换插头斯里兰卡插头 230斯洛伐克插头 230 德国/法国转换插头斯洛文尼亚插头 220 德国/法国转换插头斯威士兰插头 230苏丹插头 230 德国/法国转换插头索马里插头 220W乌干达插头 240 英国转换插头乌克兰插头 220 德国/法国转换插头乌拉圭插头 220 德国/法国转换插头乌兹别克斯坦插头 220 德国/法国转换插头西班牙插头 230 德国/法国转换插头X西萨摩亚插头 230希腊插头 220 德国/法国转换插头香港插头 200/220 英国转换插头象牙海岸插头 220 德国/法国转换插头新加坡插头 230 英国转换插头新喀里多尼亚插头 220 德国/法国转换插头新西兰插头 230 国标/澳洲转换插头匈牙利插头 230 德国/法国转换插头叙利亚插头 220 德国/法国转换插头Y牙买加插头 110 美国转换插头亚美尼亚插头 220 德国/法国转换插头亚述尔群岛插头 220 德国/法国转换插头也门插头 220 英国转换插头伊拉克插头 230 德国/法国转换插头伊朗插头 230 德国/法国转换插头以色列插头 230 德国/法国转换插头意大利插头 230 意大利转换插头印度插头 240 英国转换插头印度尼西亚插头 127/240 德国/法国转换插头英国插头 230/240 英标转换插头约旦插头 230 德国/法国转换插头越南插头 127/220 欧标/英标转换插头Z赞比亚插头 230 德国/法国转换插头乍得湖插头 220 德国/法国转换插头直布罗陀插头 230 德国/法国转换插头智利插头 220 意大利转换插头中国插头 220 国标/澳洲转换插头中非共和国插头 220 德国/法国转换插头(注:可编辑下载,若有不当之处,请指正,谢谢!)。

巴西民用,工业电压图文对照

巴西民用,工业电压图文对照

巴西民⽤,⼯业电压图⽂对照巴西民⽤电压分为:127V 和220V, 60Hz, 很多家庭是既有127⼜有220V巴西⼯业电压:⼀般分为三相220V,三相380V和三相440V。

⼀般⼈在⽹上搜索到的都是440V 60Hz, 千万不要轻易认定就是440V。

因为巴西电压分为旧⽹和新⽹,新⽹⼀般440V,圣保罗地区基本如此,旧电⽹就会⽤380V,巴西现在很多地区都是380V。

另外还有很⼤⼀部分是220V,60Hz, ⼀般⼩⼯⼚⽤的都是三相220V,⼏乎所有的⼩机器都是这个规格,尤其是机床设备。

很多⼯⼚⾥是既有三相220V,⼜有三相440V⼀般来讲⼯业设备⼀定要跟客户确认他们⼯⼚电压是多少,这个⾮常重要。

巴西插头来巴西需带什么样的转换插头上⾯边这个插头是欧标,国内很容易买到,巴西也有这种两个圆脚的插座,⽽且很常见,有的宾馆有可能只有这种插座,但是国内买的欧标的来这⾥不能⽤,因为插脚太粗,巴西的规格⼩,插不进去下⾯这种是我们笔记本电脑常⽤,也是国内最常见的三脚插头,在巴西某些地⽅也⽤到,主要是给空调⽤的插座,有些宾馆有,有些宾馆没有这种插座上⾯下⾯左边右边右边这种是国内做常见的插头,巴西也⾮常普遍,这种插座也是遍地都是,但是巴西的⽤电器⽤这种插头的很少,下⾯这个图所⽰的插头是巴西⽤电器上最常见的,两个圆脚,但是细⼀些。

下⾯这个插头也是巴西⾮常普遍的,带接地的,⼀般都是这种结构,两个扁脚平⾏加⼀个圆脚,圆脚是接地,当然圆脚也是必欧标的尺⼨⼩。

下⾯是巴西最常见的两种插座,看到这个你就知道来巴西应该带什么样的转换插头了下⾯这两种是既可以插扁脚插头,也可插圆脚插头,记得圆脚的规格要⼩于欧标的。

但是巴西还有的宾馆提供的插座只能插圆脚,⼩圆脚的那种巴西就是这么乱我最近接待了⼀个教授,说起来还是⼈家教授聪明,从来不带转换插头,他买了⼀个接线板,接上两根电线,电线的另⼀头接上两块硬的⼩铜杆,和圆脚插头差不多,但是⼩铜杆头上⼜是捶扁的,电线和⼩铜杆连接处⽤绝缘胶带缠好。

全球电源及插头规格

全球电源及插头规格

50Hz 60Hz 50Hz 50Hz 60Hz 50Hz 50Hz 50Hz
A,B,C G D
A ,B A,C C A,C,G A,C,D,G,K
双孔圆型 双孔圆型
双孔圆型 三孔方型 * 110V,60Hz
三孔方型 双孔圆型 双孔圆型 三孔圆型 三孔圆型 双孔圆型 双孔扁型 双孔圆型 双孔圆型 三孔圆型 双孔扁型 双孔圆型 双孔圆型 双孔圆型 双孔扁型
110V
60Hz
A&B
南美洲 South America
220V
50Hz
C&I
220V/230V*
50Hz
A&C
110V/220V
60Hz
A&B&C
220V
50Hz
C&L
110V
60Hz
A&B
120-127V
60Hz
A&B
220V
50Hz
C, & D&E
240V*
60Hz*
A,B,D,&G
220V
50Hz
A&B
120V
60Hz
A&B
中美洲 CE NTRAL AMERICA
110V
60Hz
C
230V
60Hz
A&B
120V
60Hz
A&B
115V
50Hz
A, B
110/220V
60Hz
B&G
120V
60Hz
A&B
120V
60Hz
A&B
110/220V
60Hz

巴西插头安规标准

巴西插头安规标准

巴西的插头标准尺寸主要有10A、20A和32A三种,主要用于供电插座和插头之间的连接。

其中,10A尺寸适用于一般家庭电器,如电视机、冰箱等;20A尺寸适用于较大功率的家庭电器,如空调、洗衣机等;而32A尺寸适用于更大功率的电器,例如电热水器。

此外,巴西的插头标准还遵循二插孔和地线的设计。

插头有两根插针,与插座内的孔相对应。

需要注意的是,插头地线插脚应为圆柱形金属,且不带有明显的弯角,这是为了确保其具有足够的机械强度和电气性能。

以上信息仅供参考,如需了解更多关于巴西插头安规标准的信息,建议查阅相关文献或咨询电气专家。

2014-各国插脚安规尺寸标准

2014-各国插脚安规尺寸标准

巴西 2PIN插脚 BLJ认证胶壳 (figure 13. NBR 14136: 2002)
印度插脚:
Indian Plug Checking Worksheet 标准:IS1293
Dimension: mm
Rated Current
Symbol
( ) 6A
( ) 16A
A
22.22±0.15
Symbol
K L M N O P Q R S
Requirement (mm) 1.57 1.57
17.2 – 18.2 22.2-23.2 3.89 - 4.05
1.57 3.89 - 4.05
R 9.5 min R 9.5 min
Measured (mm)
日规2PIN插脚胶壳--JIS C 8303:2007
Symbol B C D E F G ① ② ③
Requirement (mm) 25.5 - 26.5 90 - 92 R 5.0 – 6.0 35.0 – 36.0 13.0 – 14.4 18.8 – 19.2 > 14 mm See above See above
Measured (mm)
Symbol
Y Z a b c d e f
Requirement (mm) 1.2-2.0
R 0.1-1.0 58-62 1.35-1.85 58-62 1.35-1.85 0.2 max. 1.35-1.85
此插脚适应国家包括:英国、新加坡、马来西亚
澳规插脚 AS/NZS3112
Standard sheet Figure 2.1 (a1) or 2.1(c)
目录
1、VDE欧规胶壳插脚:标准-EN 50075/IEC60083 2、BS英规胶壳插脚:标准-BS 1363 3、SAA澳规胶壳插脚:标准-AS/NZS 3112 4、UL美规胶壳插脚:标准-ANSI-NEMA WD6 5、CCC中国规胶壳插脚:标准-GB 1002-2008 6、Korea韩国胶壳插脚:标准-KSC8305 7、Brasil巴西规胶壳插脚:NBR14136 8、India印度胶壳插脚:标准IS1293 9、Argentina阿根廷胶壳插脚:IRAM2063 10、SASO 沙特胶壳插脚:SASO-2203 11、JAPAN 日本胶壳插脚:JISC 8303 12、小南非规胶壳插脚:SABS 164-1

(参考)电源插头插座各国对比表

(参考)电源插头插座各国对比表
土耳其
C, F
230V
50Hz
丹麦
C, K
230V
50Hz
2008年六月将新增E型
芬兰
C, F
230V
50Hz
瑞典
C, F
230V
50Hz
挪威
C, F
230V
50Hz
冰岛
C, F
230V
50Hz
俄罗斯
C, F
220V
50Hz
美洲
A型
B型
C型
L型
I型
地方
插头插座
电压
频率
说明
加拿大
A, B
120V
60 Hz
秘鲁
A, B, C
220V
60 Hz
智利
C, L
220V
50 Hz
阿根廷
C, I
220V
50 Hz
该国用的I型插座火线与地线位置和其他国家相反
大洋洲
I型
地方
插头插座
电压
频率
说明
澳洲
I
230 V
50 Hz
2000年起,电压值改为230 V (有+10% -6%误差)以统一电压规格,但240 V仍很常见,且还在误差範围內,因此有不少资料仍记载240 V为主要电压
标准形式是F型,C型的插头则非常常见,特別是用在低耗电设备;但C型的插座则很少见,通常仅较老旧的配线才有
瑞士
C, J
230V
50Hz
奥地利
C, F
230V
50Hz
波兰
C, E
230V
50Hz
意大利
C, F, L
230V

巴西规插头安规图

巴西规插头安规图

NBR 14136/02 – FIGURE 14 2 poles without earthing contact (for class II equipment) from 10A to 20A, 250V~
ห้องสมุดไป่ตู้
No sharp edge
Engagement face
Note: 1 See key page 20 2 The sketches are not intended to govern design, except as regards the dimensions shown 3 Plugs can be rewirable or non-rewirable
Optional construction without the insulating sleeves
Key of page 12: 1– The earthing terminal shall be indicated by the symbol: (item 3.2.19 of NBR 11467:1991) Indication of other terminals is optional. The indications shall be placed inside the body near the terminals. There is no need to mark the terminals of non-rewirable types. 2– The distance between the engagement face and the cord or cord guard, if any, shall be at least 14 mm Compliance is checked by means of the acceptance gauge. 3– Within this distance, the outline shall be not smaller than the engagement face. 4– Within this distance, the outline shall be not larger than the engagement face. 5– Insulating sleeves on the current-carrying pins are optional If the insulating sleeves are separate parts, they shall enter the plug by at least 3mm measured from the engagement face. 6– The external diameter of the insulating sleeves shall not be larger than the diameter of the uninsulated part of the pins. 7– To avoid damage to shutters, the ends of the pins shall show neither sharp edges nor burrs. They shall be of rounded shape as shown. 8– The angle of 90° represents the maximum permissible area for the orientation of the entry of the flexible cable.

世界各国转换插头标准技术

世界各国转换插头标准技术

国家电压(V) 对应产品(插头)型号备注阿尔巴尼亚220 欧标转换插头 A 阿尔及利亚230 欧标转换插头阿富汗220 欧标转换插头阿根廷220 欧标转换插头阿拉伯联合酋长国220 欧标/英标转换插头阿鲁巴岛127 美标转换插头阿曼240 欧标转换插头埃及220 欧标转换插头埃塞俄比亚230 瑞士转换插头爱尔兰230 欧标转换插头爱沙尼亚230 欧标转换插头安哥拉220 欧标转换插头安圭拉岛110 日本转换插头安提瓜岛230 美标转换插头奥地利230 欧标转换插头澳大利亚230 国标转换插头巴巴多斯岛115 美标转换插头 B 巴布亚新几内亚240 国标转换插头巴哈马群岛120 美标转换插头巴基斯坦230 英标转换插头巴拉圭220 欧标转换插头巴利阿里群岛220 欧标转换插头巴林群岛230 英标转换插头巴拿马110 美标转换插头巴西220 美标转换插头百慕大群岛120 美标转换插头保加利亚230 欧标转换插头贝宁湾220 欧标转换插头比利时230 欧标转换插头冰岛220 欧标转换插头波多黎各120 美标转换插头波兰220 欧标转换插头波斯尼亚220 欧标转换插头玻利维亚220 欧标转换插头伯利兹城220 美标转换插头博茨瓦纳231 英标转换插头不丹230 英标转换插头布基纳法索220 欧标转换插头布隆迪220 欧标转换插头赤道几内亚220 欧标转换插头 C 丹麦220 欧标转换插头 D 德国230 欧标转换插头东帝汶220 欧标转换插头多哥220 欧标转换插头多米尼加230 英标转换插头多米尼加共和国110 日本转换插头俄罗斯220 欧标转换插头 E 厄瓜多尔120 美标转换插头厄立特里亚230 欧标转换插头法国230 欧标转换插头 F 法罗群岛220 欧标转换插头菲律宾220 美标转换插头斐济240 国标转换插头芬兰230 欧标转换插头佛得角220 欧标转换插头福克兰群岛240冈比亚230 英标转换插头 G 刚果230 欧标转换插头哥伦比亚110 美标转换插头哥斯达黎加120 美标转换插头格林纳达230 英标转换插头格陵兰220 欧标转换插头古巴110/220 欧标转换插头瓜德罗普岛230 欧标转换插头关岛120 美标转换插头圭亚那240 美标转换插头哈萨克斯坦220 欧标转换插头H 海地110 美标转换插头韩国220 欧标转换插头荷兰230 欧标转换插头洪都拉斯110 美标转换插头怀特岛240 欧标转换插头J 基里巴斯240 欧标转换插头吉布提220 欧标转换插头几内亚220 欧标转换插头几内亚比绍共和国220 欧标转换插头加拿大120 美标转换插头加纳230 英标转换插头加蓬220 欧标转换插头加沙230柬埔寨230 欧标转换插头 K 捷克斯洛伐克230 欧标转换插头津巴布韦220 英标转换插头喀麦隆220 欧标转换插头卡塔尔240 英标转换插头开曼群岛120 美标转换插头科摩罗220 欧标转换插头科威特240 欧标转换插头克罗地亚230 欧标转换插头肯尼亚240 英标转换插头拉脱维亚220 欧标转换插头 L 莱索托220老挝国230 美标转换插头黎巴嫩230 美标转换插头立陶宛220 欧标转换插头利比里亚120 美标转换插头利比亚127列支敦士登的230 瑞士转换插头卢森堡220 欧标转换插头卢旺达230 欧标转换插头罗马尼亚230 欧标转换插头马达加斯加岛220 欧标转换插头 M 马尔代夫230 英标转换插头马耳他240 英标转换插头马拉维230 英标转换插头马来群岛240 英标转换插头马里220 欧标转换插头马其顿王国220 欧标转换插头马提尼克岛220 欧标转换插头毛里求斯230 欧标转换插头毛利塔尼亚220 欧标转换插头美国120 美标转换插头蒙古230 欧标转换插头蒙特塞拉特岛230 美标转换插头孟加拉国220 欧标转换插头秘鲁220 美标转换插头密克罗尼西亚120 美标转换插头缅甸230 欧标转换插头摩洛哥220 欧标转换插头摩纳哥220 欧标转换插头莫桑比克220 欧标转换插头墨西哥127 美标转换插头纳米比亚220 N南非220/230 南非转换插头南斯拉夫220 欧标转换插头瑙鲁240 国标转换插头尼加拉瓜120 日本转换插头尼日尔220 欧标转换插头尼日利亚240 美标/英标转换插头挪威220 欧标转换插头葡萄牙220 欧标转换插头P日本100 日本插头转换插头R瑞典220 欧标转换插头瑞士230 瑞士转换插头萨尔瓦多120 美标转换插头S萨摩亚群岛120 欧标转换插头塞尔维亚230 欧标转换插头塞拉利昂230 美标/英标转换插头塞内加尔230 欧标转换插头塞浦路斯240 英标转换插头塞舌尔240 英标转换插头沙特阿拉伯127/220 美标/欧标/英标转换插头圣路易斯230 英标转换插头斯里兰卡230斯洛伐克230 欧标转换插头斯洛文尼亚220 欧标转换插头斯威士兰230苏丹230 欧标转换插头索马里220 欧标转换插头塔吉克斯坦220 欧标转换插头T塔希提岛110/220 欧标转换插头泰国220 欧标转换插头台湾110 美标转换插头坦桑尼亚230 英标转换插头汤加240突尼斯220 欧标转换插头土耳其230 欧标转换插头土库曼斯坦220 美标转换插头危地马拉120 美标转换插头W 委内瑞拉120 美标转换插头文莱240 英标转换插头乌干达240 英标转换插头乌克兰220 欧标转换插头乌拉圭220 欧标转换插头乌兹别克斯坦220 欧标转换插头西班牙230 欧标转换插头X 西萨摩亚230希腊220 欧标转换插头香港200/220 英标转换插头象牙海岸220 欧标转换插头新加坡230 英标转换插头新喀里多尼亚220 欧标转换插头新西兰230 国标转换插头匈牙利230 欧标转换插头叙利亚220 欧标转换插头牙买加110 美标转换插头Y 亚美尼亚220 欧标转换插头亚述尔群岛220 欧标转换插头也门220 英标转换插头伊拉克230 欧标转换插头伊朗230 欧标转换插头以色列230 欧标转换插头意大利230 意标转换插头印度240 英标转换插头印度尼西亚127/240 欧标转换插头英国230/240 英标转换插头约旦230 欧标转换插头越南127/220 欧标/英标转换插头赞比亚230 欧标转换插头Z 乍得湖220 欧标转换插头直布罗陀230 欧标转换插头智利220 意标转换插头中非共和国220 欧标转换插头中国220 国标转换插头A澳大利亚插头 230 澳洲转换插头阿富汗插头 220 德国/法国转换插头阿根廷插头 220 德国/法国转换插头阿拉伯联合酋长国插头 220 欧洲/英国转换插头埃及插头 220 德国/法国转换插头埃塞俄比亚插头 230 瑞士转换插头爱尔兰插头 230 德国/法国转换插头安哥拉插头 220 德国/法国转换插头安圭拉岛插头 110 日本转换插头安提瓜岛插头 230 美国转换插头奥地利插头 230 德国/法国转换插头B巴巴多斯岛插头 115 美国转换插头巴布亚新几内亚插头 240 国标/澳洲转换插头巴哈马群岛插头 120 美国转换插头巴基斯坦插头 230 英国转换插头巴拉圭插头 220 德国/法国转换插头巴利阿里群岛插头 220 德国/法国转换插头巴林群岛插头 230 英国转换插头巴拿马插头 110 美国转换插头巴西插头 220 美国转换插头百慕大群岛插头 120 美国转换插头保加利亚插头 230 德国/法国转换插头贝宁湾插头 220 德国/法国转换插头比利时插头 230 德国/法国转换插头冰岛插头 220 德国/法国转换插头波多黎各插头 120 美国转换插头波兰插头 220 德国/法国转换插头波斯尼亚插头 220 德国/法国转换插头玻利维亚插头 220 德国/法国转换插头伯利兹城插头 220 美国转换插头博茨瓦纳插头 231 英国转换插头D丹麦插头 220 德国/法国转换插头德国插头 230 德国/法国转换插头东帝汶插头 220 德国/法国转换插头多哥插头 220 德国/法国转换插头多米尼加插头 230 英国转换插头多米尼加共和国插头 110 日本转换插头E俄罗斯插头 220 德国/法国转换插头厄瓜多尔插头 120 美国转换插头厄立特里亚插头 230 德国/法国转换插头F法国插头 230 德国/法国转换插头法罗群岛插头 220 德国/法国转换插头菲律宾插头 220 美国转换插头芬兰插头 230 德国/法国转换插头佛得角插头 220 德国/法国转换插头福克兰群岛插头 240G刚果插头 230 德国/法国转换插头哥伦比亚插头 110 美国转换插头哥斯达黎加插头 120 美国转换插头古巴插头 110/220 德国/法国转换插头瓜德罗普岛插头 230 德国/法国转换插头关岛插头 120 美国转换插头圭亚那插头 240 美国转换插头H哈萨克斯坦插头 220 德国/法国转换插头海地插头 110 美国转换插头韩国插头 220 德国/法国转换插头荷兰插头 230 德国/法国转换插头洪都拉斯插头 110 美国转换插头怀特岛插头 240 德国/法国转换插头J加拿大插头 120 美国转换插头加纳插头 230 英国转换插头加蓬插头 220 欧洲转换插头加沙插头 230柬埔寨插头 230 德国/法国转换插头K捷克斯洛伐克插头 230 德国/法国转换插头津巴布韦插头 220 英国转换插头喀麦隆插头 220 德国/法国转换插头卡塔尔插头 240 英国转换插头开曼群岛插头 120 美国转换插头科摩罗插头 220 德国/法国转换插头科威特插头 240 德国/法国转换插头克罗地亚插头 230 德国/法国转换插头肯尼亚插头 240 英国转换插头拉脱维亚插头 220 德国/法国转换插头L莱索托插头 220老挝国插头 230 美国转换插头黎巴嫩插头 230 美国转换插头立陶宛插头 220 德国/法国转换插头利比里亚插头 120 美国转换插头利比亚插头 127列支敦士登的插头 230 瑞士转换插头卢森堡插头 220 德国/法国转换插头卢旺达插头 230 德国/法国转换插头罗马尼亚插头 230 德国/法国转换插头马达加斯加岛插头 220 德国/法国转换插头M马尔代夫插头 230 英国转换插头马耳他插头 240 英国转换插头马拉维插头 230 英国转换插头马来群岛插头 240 英国转换插头马里插头 220 德国/法国转换插头马其顿王国插头 220 德国/法国转换插头马提尼克岛插头 220 德国/法国转换插头毛里求斯插头 230 德国/法国转换插头毛利塔尼亚插头 220 德国/法国转换插头美国插头 120 美国转换插头蒙古插头 230 德国/法国转换插头蒙特塞拉特岛插头 230 美国转换插头孟加拉国插头 220 德国/法国转换插头秘鲁插头 220 美国转换插头密克罗尼西亚插头 120 美国转换插头缅甸插头 230 德国/法国转换插头摩洛哥插头 220 德国/法国转换插头摩纳哥插头 220 德国/法国转换插头莫桑比克插头 220 德国/法国转换插头墨西哥插头 127 美国转换插头纳米比亚插头 220N南非插头 220/230 南非转换插头南斯拉夫插头 220 德国/法国转换插头瑙鲁插头 240 国标/澳洲转换插头尼加拉瓜插头 120 日本转换插头尼日尔插头 220 德国/法国转换插头挪威插头 220 德国/法国转换插头P葡萄牙插头 220 德国/法国转换插头R日本插头 100 日本转换插头瑞典插头 220 德国/法国转换插头瑞士插头 230 瑞士转换插头塞浦路斯插头 240 英国转换插头塞舌尔插头 240 英国转换插头沙特阿拉伯插头 127/220 美国/欧洲/英国转换插头圣路易斯插头 230 英国转换插头斯里兰卡插头 230斯洛伐克插头 230 德国/法国转换插头斯洛文尼亚插头 220 德国/法国转换插头斯威士兰插头 230苏丹插头 230 德国/法国转换插头索马里插头 220W乌干达插头 240 英国转换插头乌克兰插头 220 德国/法国转换插头乌拉圭插头 220 德国/法国转换插头乌兹别克斯坦插头 220 德国/法国转换插头X西萨摩亚插头 230希腊插头 220 德国/法国转换插头香港插头 200/220 英国转换插头象牙海岸插头 220 德国/法国转换插头新加坡插头 230 英国转换插头新喀里多尼亚插头 220 德国/法国转换插头新西兰插头 230 国标/澳洲转换插头匈牙利插头 230 德国/法国转换插头叙利亚插头 220 德国/法国转换插头Y牙买加插头 110 美国转换插头亚美尼亚插头 220 德国/法国转换插头亚述尔群岛插头 220 德国/法国转换插头也门插头 220 英国转换插头伊拉克插头 230 德国/法国转换插头伊朗插头 230 德国/法国转换插头以色列插头 230 德国/法国转换插头意大利插头 230 意大利转换插头印度插头 240 英国转换插头印度尼西亚插头 127/240 德国/法国转换插头英国插头 230/240 英标转换插头约旦插头 230 德国/法国转换插头越南插头 127/220 欧标/英标转换插头Z赞比亚插头 230 德国/法国转换插头乍得湖插头 220 德国/法国转换插头直布罗陀插头 230 德国/法国转换插头智利插头 220 意大利转换插头中国插头 220 国标/澳洲转换插头中非共和国插头 220 德国/法国转换插头。

世界各国 适配器 充电器 规格 详细参数

世界各国 适配器 充电器 规格 详细参数

世界各国适配器充电器规格详细参数查询外贸用!世界各国充电器规格查询国家电压(伏) 使用插头•英国230 英联邦插头•法国230 德法两用插头•德国230 德法两用插头•美国120 美式插头•加拿大120 美式插头•澳大利亚230 澳大利亚插头•意大利230 欧规•瑞士230 瑞士插头•日本100 日本插头•阿富汗220 德法两用插头•阿尔巴尼亚220 德法两用插头•阿尔及利亚230 德法两用插头•萨摩亚群岛120 德法两用插头•安哥拉220 德法两用插头•安圭拉岛110 日本插头•安提瓜岛230 美式插头•阿根廷220 德法两用插头•亚美尼亚220 德法两用插头•阿鲁巴岛127 美式插头•亚述尔群岛220 德法两用插头•巴林群岛230 英联邦插头•巴利阿里群岛220 德法两用插头•孟加拉国220 德法两用插头•巴巴多斯岛115 美式插头•伯利兹城220 美式插头•贝宁湾220 德法两用插头•比利时230 德法两用插头•奥地利230 德法两用插头•百慕大群岛120 美式插头•不丹230 英联邦插头•玻利维亚220 德法两用插头•波斯尼亚220 德法两用插头•博茨瓦纳231 英联邦插头•巴西220 美式插头•文莱240 英联邦插头•保加利亚230 德法两用插头•布基纳法索220 德法两用插头•布隆迪220 德法两用插头•柬埔寨230 德法两用插头•喀麦隆220 德法两用插头•佛得角220 德法两用插头•中非共和国220 德法两用插头•乍得湖220 德法两用插头•智利220 意大利插头•哥伦比亚110 美式插头•科摩罗220 德法两用插头•刚果230 德法两用插头•哥斯达黎加120 美式插头•象牙海岸220 德法两用插头•克罗地亚230 德法两用插头•古巴110/220 德法两用插头•塞浦路斯240 英联邦插头•捷克斯洛伐克230 德法两用插头•丹麦220 德法两用插头•吉布提220 德法两用插头•多米尼加230 英联邦插头•多米尼加共和国110 日本插头•东帝汶220 德法两用插头•厄瓜多尔120 美式插头•埃及220 德法两用插头•萨尔瓦多120 美式插头•赤道几内亚220 德法两用插头•厄立特里亚230 德法两用插头•爱沙尼亚230 德法两用插头•埃塞俄比亚230 瑞士插头•法罗群岛220 德法两用插头•福克兰群岛240•斐济240 澳大利亚插头•芬兰230 德法两用插头•加沙230•加蓬220 德法两用插头•冈比亚230 英联邦插头•加纳230 英联邦插头•直布罗陀230 德法两用插头•希腊220 德法两用插头•格陵兰220 德法两用插头•格林纳达230 英联邦插头•瓜德罗普岛230 德法两用插头•关岛120 美式插头•危地马拉120 美式插头•几内亚220 德法两用插头•几内亚比绍共和国220 德法两用插头•圭亚那240 美式插头•海地110 美式插头•香港220 英联邦插头•匈牙利230 德法两用插头•冰岛220 德法两用插头•印度240 英联邦插头•印尼127/240 英联邦插头•伊朗230 德法两用插头•伊拉克230 德法两用插头•爱尔兰230 德法两用插头•怀特岛240 德法两用插头•以色列230 德法两用插头•牙买加110 美式插头•约旦230 德法两用插头•肯尼亚240 英联邦插头•哈萨克斯坦220 德法两用插头•基里巴斯240 澳大利亚插头•韩国220 德法两用插头•科威特240 德法两用插头•老挝国230 美式插头•拉脱维亚220 德法两用插头•黎巴嫩230 美式插头•莱索托220•利比亚127•立陶宛220 德法两用插头•列支敦士登的230 瑞士插头•卢森堡220 德法两用插头•马其顿王国220 德法两用插头•马达加斯加岛220 德法两用插头•马拉维230 英联邦插头•马来群岛240 英联邦插头•马尔代夫230 英联邦插头•马里220 德法两用插头•马耳他240 英联邦插头•马提尼克岛220 德法两用插头•毛利塔尼亚220 德法两用插头•毛里求斯230 德法两用插头•墨西哥127 美式插头•密克罗尼西亚120 美式插头•摩纳哥220 德法两用插头•蒙古230 德法两用插头•蒙特塞拉特岛230 美式插头•摩洛哥220 德法两用插头•莫桑比克220 德法两用插头•缅甸230 德法两用插头•纳米比亚220•瑙鲁240 澳大利亚插头•荷兰230 德法两用插头•印度尼西亚127/240 英联邦插头•新喀里多尼亚220 德法两用插头•新西兰230 澳大利亚插头•尼加拉瓜120 日本插头•尼日尔220 德法两用插头•尼日利亚240 英联邦插头•挪威220 德法两用插头•阿曼240 德法两用插头•巴基斯坦230 英联邦插头•巴拿马110 美式插头•巴布亚新几内亚240 澳大利亚插头•巴拉圭220 德法两用插头•秘鲁220 美式插头•菲律宾220 美式插头•波兰220 德法两用插头•葡萄牙220 德法两用插头•波多黎各120 美式插头•卡塔尔240 英联邦插头•俄罗斯220 德法两用插头•卢旺达230 德法两用插头•圣路易斯230 英联邦插头•沙特阿拉伯127\220 美式插头•德法两用插头•英联邦插头•塞内加尔230 德法两用插头•塞尔维亚230 德法两用插头•塞拉利昂230 英联邦插头•塞舌尔240 英联邦插头•新加坡230 英联邦插头•斯洛伐克230 德法两用插头•斯洛文尼亚220 德法两用插头•索马里220 德法两用插头•南非220/230•西班牙230 德法两用插头•斯里兰卡230•苏丹230 德法两用插头•斯威士兰230•瑞典220 德法两用插头•瑞士230 瑞士插头•塔希提岛110/220 德法两用插头•塔吉克斯坦220 德法两用插头•坦桑尼亚230 英联邦插头•泰国220 德法两用插头•多哥220 德法两用插头•汤加240•突尼斯220 德法两用插头•土耳其230 德法两用插头•土库曼斯坦220 美式插头•乌干达240 英联邦插头•乌克兰220 德法两用插头•阿拉伯联合酋长国220 德法两用插头•英联邦插头•乌拉圭220 德法两用插头•乌兹别克斯坦220 德法两用插头•委内瑞拉120 美式插头•越南127/220 英联邦插头•德法两用插头•西萨摩亚230•也门220 英联邦插头•南斯拉夫220 德法两用插头•津巴布韦220 英联邦插头••中国220 中国插头备注:1. 220V-230V高台圆插:德法两用插头/瑞士插头2. 110V-120V两脚扁插带孔:美式插头/日本插头3. 240V三脚八字插/两脚八字插:澳大利亚插头4. 230V厚三脚:英联邦插头借此贴从穷游等站转世界各国电源转换插头,插座图解欧洲各国电源插座一览【请点击图片放大看清晰图片】除了转换插头之外,还需要考虑电压的兼容性. 欧洲的电压为220 -230伏和中国一致。

世界各国电源插头标准和电压标准(二)

世界各国电源插头标准和电压标准(二)

说明 意大利规格三脚圆 型 / 欧规双脚圆型 欧洲规格双脚圆型 欧洲规格双脚圆型 欧洲规格双脚圆型 欧洲规格双脚圆型 欧洲规格双脚圆型 欧洲规格双脚圆型 欧洲规格双脚圆型 欧洲规格双脚圆型 英规三脚扁型 英规三脚扁型 欧洲规格双脚圆型 瑞士规格三脚圆型 / 欧洲规格双脚圆 欧洲规格双脚圆型 欧洲规格双脚圆型 欧洲规格双脚圆型 欧洲规格双脚圆型 欧洲规格双脚圆型 丹麦规格三脚圆型 / 欧洲规格双脚圆 欧洲规格双脚圆型 八字型 / 欧洲规格 双脚圆型 欧洲规格双脚圆型
加彭 / Gabon 迦纳 / Ghana 赤道几内亚 / Equatorial Guinea 奈及利亚 / Nigeria 喀麦隆 / Cameroon
220-240V 220V 220V 220-224V 220V
50Hz 50Hz 50Hz 50Hz 50Hz
G E, I & K E & F I E, F & G
世界各国电源插头标准和电压标准(二)
亚洲地区
国家或地区(中文/英文) 日本/ Japan 中国 / China 韩国 / Korea 香港 / Hong-Kong 澳门 / Macau 澳大利亚 / Australia 纽西兰 / New-Zealand 越南 / Vietnam 泰国 / Thailand 马来西亚 / Malaysia 新加坡 / Singapore 菲律宾 / Philippines 印度尼西亚 / Indonesia 印度 / India 电压 100V 220V 220V 220V 220V 240V 220V 120/220V 220V 230V 220V 220V 220V 230V 频率 50Hz, 60Hz 50Hz 50Hz, 60Hz 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz 插头型式 A & B D & J E & G I I C & D C & D A, B, E & G A & B I I A & B E & G K & L

巴西插头尺寸标准

巴西插头尺寸标准

Engagement faceNo sharp edgeEarthing pin and optional constructionfor the contact pinsKey of page 12:1– The earthing terminal shall be indicated by the symbol .Indication of the other terminals is optional.The indications shall be placed inside the body near the terminals.There is no need to mark the terminals of non-rewirable types2– The distance between the engagement face and the cord or cord guard, if any, shall be at least 14 mmCompliance is checked by means of the acceptance gauge (under consideration)3– Within this distance, the outline shall be not smaller than the engagement face. 4– Within this distance, the outline shall be not larger than the engagement face.5– Insulating sleeves on the current-carrying pins are optionalIf the insulating sleeves are separate parts, they shall enter the plug by at least3mm measured from the engagement face.6– The external diameter of the insulating sleeves shall not be larger than the diameter of the uninsulated part of the pins.7– To avoid damage to shutters, the ends of the pins shall show neither sharp edges nor burrs. They shall be of rounded shape as shown.8– The angle of 90° represents the maximum permissible area for the orientation of the entry of the flexible cable or cord.Engagement faceNo sharp edgeOptional construction without theinsulating sleevesKey of page 20:1– The distance between the engagement face and the cord or cord guard, if any, shall be at least 14 mm2– Within this distance, the outline shall be not smaller than the engagement face. 3– Within this distance, the outline shall be not larger than the engagement face.4– Insulating sleeves on the current-carrying pins are optionalIf the insulating sleeves are separate parts, they shall enter the plug by at least3mm measured from the engagement face.5– The external diameter of the insulating sleeves shall not be larger than the diameter of the uninsulated part of the pins.6– To avoid damage to shutters, the ends of the pins shall show neither sharp edges nor burrs. They shall be of rounded shape as shown.7– The angle of 90° represents the maximum permissible area for the orientation of the entry of the flexible cable or cord.。

巴西用电标准

巴西用电标准

巴西用电标准
巴西的用电标准是220伏特、60赫兹的交流电。

这是与欧洲和澳大利亚相同的电压和频率。

如果您计划前往巴西,需要注意以下几点:
1.插座类型
巴西使用两种不同的插座类型。

其中一种是两个圆形插头,类似于欧洲的C形插头。

另一种则是三个平行长方形插头,类似于美国的A形插头。

因此,您可能需要带上万能转换插头或特殊的转换器。

2.电压适配器
在巴西使用电器时,需要注意电压适配器的问题。

由于巴西的电压是220伏特,如果您的设备只能适配110伏特电压,将不能使用。

3.可充电设备
如果您携带可充电设备,比如手机和实时定位系统,注意对于这类设备的充电器不能同时使用两项功能,即充电和工作。

需要先将设备充满电,再使用。

总之,如果您计划前往巴西,需要了解巴西的用电标准并进行相应的准备。

如果您不确定如何处理电器方面的问题,最好事先咨询旅游机构或当地的电器商店。

这样可以确保您的设备能够在巴西顺利运转,并且避免不必要的麻烦。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

NOVEMBER 2002NBR 14136ABNT - Brazilian Association ofT echnical Standards Plugs and socket-outlets for household and similar purposes up to20 A/250 Va.c. - StandardizationOrigin: Project NBR 14136:2001CE-03:023.02 - Study Commission for Switches, Socket-outlets, Pins and Plates for General UseNBR 14136 - Plugs and socket-outlets for household and similar purposes StandardizationDescriptors: Plug. Socket-outletThis Standard has been based on IEC 60906-1:1986This Standard cancels and replaces NBR 14136:1998Valid from December 29, 2002 onKey-words: Plug. Socket-outlet20 pagesSummaryForeword1Objective2Normative references3RequirementsANNEXA FiguresForewordABNT – The Brazilian Association of Technical Standards - is the National Committee of Standardization. The Brazilian standards, which content is responsibility of Brazilian Committees (ABNT/CB) and the Organizations of Sectorial Standardization (ABNT/ONS), are elaborated by Study Commissions (CE), composed by representatives of the involved sections, like: producers, consumers and neutral (universities, laboratories and other).The drafts of Brazilian standards, elaborated in the extent of ABNT/CB and ABNT/ONS, are circulated for Public Consultation among ABNT associates and interested parties.This Standard contains the annex A, it is normative.1Scope1.1This Standard sets the dimensions for plugs and socket-outlets with nominalcharacteristics up to 20 A/250 V a.c., intended for household and similar purposes, to be used in the connection to distribution systems with nominal tensions rated between 100 V and 250 V a.c.1.2This Standard is applied to the plugs and socket-outlets specified in NBR 6147.1.3This Standard is not applied to the plugs and socket-outlets designed to theclass 0 equipments.2Normative referencesThe following normative documents contain provisions which, through reference in this text, constitute provisions of this Standard. The indicated issues were in force when this Standard was published. As every Standard might suffer revisions, it is recommended to those that accomplish agreements based on this document to verify the convenience of using the most recent issue of the mentioned Standards. ABNT maintains registers of currently valid editions.NBR 6147:2000 - Plugs and socket-outlets for household and similar purposes - SpecificationNBR 11467:1991 - graphic Symbols for use in equipments - Symbols2 NBR14136:20023Requirements3.1DimensionsThe plugs and socket-outlets shall be in agreement with the dimensions of theappropriate figures of annex A.3.2CompatibilityThe 20A socket-outlets shall admit the insertion of 10 A and 20 A plugs, and the socket-outlets with earthing-contact shall admit the insertion of plugs with and without earthing-pin.The 10 A socket-outlets shall not admit the insertion of 20 A plugs./ ANNEX ANBR14136:2002 3Annex A (normative)FiguresDimensions in millimetersSharp edgesslightly roundedDetail of theentrance holesProtecting surfaceNOTES1See explanatory notes on page 9.2These figures are not intended to govern the plan, except in the shown dimensions.3Several constructions can be used, such as multiple socket-outlets.Figure 1 – Socket-outlet to built-in, two-pole, with earthing contact - 10 A/250 V c.a.4 NBR14136:2002Dimensions in millimetersSharp edgesslightly roundedDetail of theentrance holesProtecting surface NOTES1See explanatory notes on page 9.2These figures are not intended to govern the plan, except in the shown dimensions.3 Several constructions can be used, such as multiple socket-outlets.Figure 2 – Socket-outlet to built-in, two-pole, with earthing contact - 20 A/250 Vc.a.NBR14136:2002 5Dimensions in millimetersProtecting surfaceWith protecting surface Without protecting surfaceNOTES1See explanatory notes on page 9.2For the dimensions that were not indicated see figure 1.3These figures are not intended to govern the plan, except in the shown dimensions.4Several constructions can be used, such as multiple socket-outlets.Figure 3 - Socket-outlet to semi-built-in or to put upon, two-pole, with earthing-contact - 10 A/250 Vc.a.6 NBR14136:2002Dimensions in millimetersProtecting surfaceWith protecting surface Without protecting surfaceNOTES1See explanatory notes on page 9.2For the dimensions that were not indicated see figure 2.3 These figures are not intended to govern the plan, except in the shown dimensions.4 Several constructions can be used, such as multiple socket-outlets.Figure 4 – Socket-outlet to semi-built-in or to put upon, two-pole, with earthing-contact - 20 A/250 Vc.a.NBR14136:2002 7Dimensions in millimeters With recess With collarProtecting surfaceWith protecting surface Without protecting surfaceNOTES1See explanatory notes on page 9.2For the dimensions that were not indicated see figure 1.3These figures are not intended to govern the plan, except in the shown dimensions.4Several constructions can be used, such as multiple socket-outlets.Figure 5 – Portable socket-outlet, two-pole, with earthing contact. - 10 A/250 Vc.a.8 NBR14136:2002Dimensions in millimeters With recess With collarProtecting surfaceWith protecting surface Without protecting surfaceNOTES1See explanatory notes on page 9.2For the dimensions that were not indicated see figure 2.3These figures are not intended to govern the plan, except in the shown dimensions.4Several constructions can be used, such as multiple socket-outlets.Figure 6 – Portable socket-outlet, two-pole, with earthing contact. - 20 A/250 Vc.a.NBR14136:2002 9 Explanatory notes for figures 1, 2, 3, 4, 5 and 6Î A recess shall be provided for socket-outlets to built-in, a collar for those to put upon or for portable types, or a combination of both for the semi-built-in type.For the semi-built-in socket-outlets, the impossibility of single-pole insertion shall be verified.ÏIf those dimensions were not respected, a gauge shall be used for verifying theimpossibility of single-pole insertion.Regarding the use of shutters as the only way to prevent single-pole insertion, see NBR 6147.ÐThis dimension has been provided for the plate, the guide of the plug pins and for the eventual shutter mechanism. The shutters are optional.It is not necessary to supply a proper space to the shutters in those models without this device.ÑIn the limits of that thickness, the guide for the plug pins shall have at least 1,5 mm with the specified diameter.ÒSmall chamfer or radius.ÓThe points that first touch the alive contacts and the earthing-contact shall be verified.ÔThis dimension is verified using a gauge in the most unfavorable conditions.ÕThe contacts shall be elastic. Their shape might be different from the tubular.An entrance in an appropriate way, with a chamfer or a radius, is necessary to prevent damage of the contact when the plug is inserted in the most unfavorable angle.Its convenience is verified by performing all the tests specified in NBR 6147.ÖThe earthing-terminal shall be identified with the symbol (3.2.19 of NBR 11467:1991).The identification of the other terminals is optional.The marking shall be put close to the terminals.It is not necessary to mark the terminals in those models that cannot by disassembled.10 NBR14136:2002Dimensions in millimetersEngagement faceNo sharp edgesEarthing-pin and optional constructionfor the pin that carries current (alive) NOTES1See explanatory notes on page 12.2These figures are not intended to govern the plan, except in the shown dimensions.3The plugs can, or cannot, be disassembled.Figure 7 – Two-pole Plug, with earthing-pin (for class I appliances) up to 10 A/250 Vc.a.Dimensions in millimetersNOTES1See explanatory notes on page 12.2These figures are not intended to govern the plan, except in the shown dimensions.3The plugs can, or cannot, be disassembled.Figure 8 – Two-pole Plug, with earthing-pin (for class I appliances) above 10 A up to 20 A/250 Vc.a.Engagement faceEarthing-pin and optional construction for the pin that carries current (alive)No sharp edgesExplanatory notes for figures 7 and 8ÎThe earthing-terminal shall be identified with the symbol (3.2.19 of NBR 11467:1991).The identification of the other terminals is optional.The marking shall be made inside the body, close to the terminals.It is not necessary to mark the terminals in those models that cannot be disassembled.ÏThe distance between the engagement face and the cord or the exit for the cable or the eventual cord protection shall be of 14 mm, at least.The conformity is verified by measurement.ÐIn the limits of this dimension, the outline shall not be smaller than the outline of the engagement face.ÑIn the limits of this dimension, the outline should not be larger than outline of the engagement face.ÒThe insulating sleeves of the alive pins are optional.If the insulating sleeves are separated parts, they shall penetrate in the body of the plug in, at least, 3 mm measured from the engagement face.ÓThe external diameter of the insulating sleeves shall not overcome the uncovered part of the pins.ÔTo avoid the shutters damage, the extremities of the pins shall not present sharp edges or burrs; they shall be rounded, as shown.ÕThe angle of 90º sets the maximum area which the flexible cord entrance shall be allowed.Dimensions in millimetersDetail of theentrance holesNOTES1See explanatory notes on page 17.2The socket-outlets can, or cannot, be disassembled.3These figures are not intended to govern the plan, except in the shown dimensions.4Several constructions can be used, such as multiple socket-outlets.Figure 9 – Portable two-pole socket-outlet without earthing-contact - 10 A/250 Vc.a.Dimensions in millimetersDetail of the entranceholesNOTES1See explanatory notes on page 17.2The socket-outlets can, or cannot, be disassembled.3These figures are not intended to govern the plan, except in the shown dimensions.4Several constructions can be used, such as multiple socket-outlets.Figure 10 - Portable two-pole socket-outlet without earthing-contact - 20 A/250 Vc.a.Dimensions in millimeters With recess With collarProtecting surfaceNOTES1See explanatory notes on page 17.2The socket-outlets can, or cannot, be disassembled.3These figures are not intended to govern the plan, except in the shown dimensions.4Several constructions can be used, such as multiple socket-outlets.Figure 11 - Portable two-pole socket-outlet without earthing-contact with protecting surface - 10 A/250 Vc.a.Dimensions in millimetersWith recess With collarProtecting surfaceNOTES1See explanatory notes on page 17.2For the dimensions that were not indicated, see Figure 10.3These figures are not intended to govern the plan, except in the shown dimensions.4Several constructions can be used, such as multiple socket-outlets.Figure 12 - Portable two-pole socket-outlet without earthing-contact with protecting surface - 20 A/250 Vc.a.Explanatory notes for figures 9, 10, 11 and 12.These Figures are equally provided for socket-outlets which are incorporated in appliances.Î A collar shall be provided for the models without protecting surface or a recess, or a combination of a collar and a recess for the socket-outlets with protecting surface.In cases of such combination the impossibility of single-pole insertion shall be verified.ÏIf those dimensions were not respected, a gauge shall be used for verifying the impossibility of single-pole insertion. Regarding the use of shutters as the only way to prevent single-pole insertion, see NBR 6147.ÐThis dimension has been provided for the plate, the guide of the plug pins and for the eventual shutter mechanism. These shutters are optional.It is not necessary to supply a proper space to the shutters in those models without this device.ÑIn the limits of that thickness, the guide for the plug pins shall have at least 1,5 mm with the specified diameter.ÒSmall chamfer or radius.ÓThe points that first contact shall be verified with a gauge.ÔThe contacts shall be elastic. Their shape might be different from the tubular.An entrance in an appropriate way, with a chamfer or a radius, is necessary to prevent the damage of the contact when the plug is inserted in the most unfavorable angle. Its convenience is verified by performing all the tests specified in NBR 6147.Dimensions in millimetersEngagement faceOptional construction withoutinsulating sleevesNOTES1See explanatory notes on page 20.2These figures are not intended to govern the plan, except in the shown dimensions.3This plug can, or cannot, be disassembled.Figure 13 - Two-pole Plug without earthing-pin (for class II appliances) up to 10 A/250 V a.c.Dimensions in millimetersEngagement faceOptional construction withoutinsulating sleevesNOTES1See explanatory notes on page 20.2These figures are not intended to govern the plan, except in the shown dimensions.3This plug can, or cannot, be disassembled.Figure 14 - Two-pole Plug without earthing-pin (for class II appliances) above 10 A up to 20 A/250 Vc.a.Explanatory notes for figures 13 and 14ÎThe distance between the engagement face and the cord or the exit for the cord or the eventual protection of the cord shall be 14 mm, at least.The conformity is verified by measurement.ÏIn the limits of this dimension, the outline shall not be smaller than the outline of the engagement face.ÐIn the limits of that dimension, the outline shall not be larger than the outline of the engagement face.ÑThe insulating sleeves of the alive pins are optional.If the insulating sleeves are separated parts, they shall penetrate in the body of the plug in, at least, 3 mm measured from the engagement face.ÒThe external diameter of the insulating sleeves shall not overcome the uncovered part of the pins.ÓTo avoid the shutters damage, the extremities of the pins shall not present sharp edges or burrs; they shall be rounded, as shown.ÔThe angle of 90º sets the maximum area which the flexible cord entrance shall be allowed.。

相关文档
最新文档