加拿大BWGAMIC-5系列多功能气体检测仪
BW Technologies by Honeywell 的气体检测仪说明书
![BW Technologies by Honeywell 的气体检测仪说明书](https://img.taocdn.com/s3/m/b916de42a200a6c30c22590102020740be1ecd8c.png)
Certificate of Compliance Certificate:1730355 Master Contract: 157918 Project:70024685 Date Issued: April 05, 2015Issued to: BW Technologies by Honeywell2840 2nd Ave SECalgary, Alberta T2A 7X9CANADAAttention: Stephen Uliasz The products listed below are eligible to bear the CSA Mark shownwith adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only.Issued by: Gary BendenGary BendenPRODUCTS4828 01 - SIGNAL APPLIANCES - Combustible Gas Detection Instruments - For Hazardous Locations 4828 02 - SIGNAL APPLIANCES - Toxic Gas Detection Instruments - For Hazardous Locations4828 81 - SIGNAL APPLIANCES - Combustible Gas Detection Instruments - For Hazardous Locations -Certified to U.S. Standards4828 82 - SIGNAL APPLIANCES - Toxic Gas Detection Instruments - For Hazardous Locations -Certified to U.S. StandardsClass I, Division 1; Groups A, B, C and/or D; T4GasAlertMicroClip XT Portable Gas Detector, MC2-XWHM-a-bb-cc Temperature Code T4 @ -20°C ≤ Ta ≤ +58°C; Multi-gas detectors for monitoring up to four gasses simultaneously and continuously i.e. Oxygen[deficiency/enrichment], Combustibles, Carbon Monoxide and Hydrogen sulphide ; Intrinsically Safe when powered by a non user replaceable Narada Lithium Polymer battery Part Number: NL503759.GasAlertMicroClip XL Portable Gas Detector, MCXL-XWHM-a-bb Temperature Code T4 @ -20°C ≤ Ta ≤ +50°C; Multi-gas detectors for monitoring up to four gasses simultaneously and continuously i.e. Oxygen[deficiency/enrichment], Combustibles, Carbon Monoxide and Hydrogen sulphide ; Intrinsically Safe when powered by a non user replaceable Narada Lithium Polymer battery Part Number: NLP883759LT20.Certificate:1730355 Project:70024685Master Contract:157918 Date Issued:April 05, 2015GasAlertMicroClip X3 Portable Gas Detector, MCX3-XWHM-a-bb Temperature Code T4 @ -20°C ≤ Ta ≤+50°C; Multi-gas detectors for monitoring up to four gasses simultaneously and continuously i.e. Oxygen [deficiency/enrichment], Combustibles, Carbon Monoxide and Hydrogen sulphide ; Intrinsically Safe when powered by a non user replaceable Narada Lithium Polymer battery Part Number: NLP883759LT20.APPLICABLE REQUIREMENTSCSA Standard C22.2 No. 0-2010 General Requirements Canadian Electrical Code Part II.CSA Standard C22.2 No. 152-M1984 Combustible Gas Detection InstrumentsCSA Standard C22.2 No. 157-92 Intrinsically Safe and Non-Incendive Equipment for Use in HazardousLocationsUL Standard 913, Seventh Edition Intrinsically Safe Apparatus and Associated Apparatus for use in ClassI, II, III, Division 1, Hazardous (Classified) LocationsANSI/ISA-12.13.01-2000 Performance Requirements for Combustible Gas DetectorsMARKINGSThe manufacturer is required to apply the following markings:•Products shall be marked with the markings specified by the particular product standard.•Products certified for Canada shall have all Caution and Warning markings in both English and French. Additional bilingual markings not covered by the product standard(s) may be required by the Authorities Having Jurisdiction. It is the responsibility of the manufacturer to provide and apply these additional markings, where applicable, in accordance with the requirements of those authorities.Marking On Main Unit:(1)Submittor's name, trademark, or the CSA file number (adjacent the CSA Mark).(2)Catalogue / Model designation.(3)Date code / Serial number traceable to month and year of manufacture.(4)Hazardous Location designations, Class I, Division 1; Groups A, B, C and/or D; T4 (May beabbreviated Cl. I Gr. A, B, C, D T4).(5)The symbol “Exia” and the words “Intrinsically Safe”, and “Sécurité Intrinsèque”.(6)“Read and understand manual” and “Lire et comprendre le manuel”.(7)C22.2 No 152, S12.13.(8)The CSA Mark with or without the “c” and/or “us” qualifiers.(9)Temperature Code Rating, T4.(10)Ambient Temperature Range -20°C ≤ Ta ≤ +58°C, or -20°C ≤ Ta ≤ +50°C, as applicable.(11)Optional Hazardous Location designations, Class I, Zone 0, IIC.(12)WARNING: Battery must be charged in a non-hazardous area and may only be replaced by themanufacturer. (May be in user manual).(13)WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY. (May bein User Manual).Supplement to Certificate of ComplianceCertificate:1730355 Master Contract:157918The products listed, including the latest revision described below,are eligible to be marked in accordance with the referenced Certificate.Product Certification HistoryProject Date Description70024685 Apr 5 2015 Update of Report 1730355 to include addition of a new modelGasAlertMicroClip X3 and additionally include a crystal component changeto the GasAlertMicroClip XT/XL.70018883 Feb 27 2015 Update to Report 1730355 to include firmware change for modelsGasAlertMicroClip XT and XL.2710384 Jul 21 2014 Update to report 1730355 to add new model GasAlertMicroClip XL;MCXL-XWHM-a-bb; Temperature Code T4 @ -20°C # Ta # +50°C;Powered by Part Number: NLP883759LT20.2689722 Feb 28 2014 Update report to cover removing GasAlertMicroClip, Lithium Polymerbatteries (Varta PLF 503759, PLF 503759D, PLF 503759C, BYD SL503759), Micropel 40-CITY TECHNOLOGY; revising drawings to includefuse, resistors and transistors changes.2618343 Jul 25 2013 HAZ 130139: Update to Report1730355 to cover revised firmware (rev.40F).2451746 Aug 31 2011 Update report 1730355 to add test confirmation for revised internal lowbattery alarm operating parameter.2305825 Dec 15 2010 Update to report 1730355 to include new battery and alternate O2 sensorwhich results in the creation of the Gas Alert Micro Clip XT.2249935 Jan 12 2010 Update to Report 1730355 to include alternate vibrator motor.2102246 Nov 28 2008 Update to report 173055 to add new battery.2033112 May 1 2008 Update of report 1730355 to allow the product to be built at BWT Calgaryand at Systems Sensor de Mexico in Juarez.1888493 Mar 22 2007 Update to Report 1730355 to include new battery1816037 Oct 6 2006 Update to Report 1730355 to include brown out chip, MicroPel 75 sensorand new battery (includes performance testing).1773170 Apr 21 2006 Update to report 1730355 to correct order number, upgrade firmware and addalternate components1730355 Dec 8 2005 GasAlertMicroClip Portable Gas Detector for use in Hazardous Locations。
bw gasalertmicroclip xt多气体检测器手册说明书
![bw gasalertmicroclip xt多气体检测器手册说明书](https://img.taocdn.com/s3/m/692bcc57a31614791711cc7931b765ce05087a0b.png)
multi-gas detector•Continuous visual compliance with IntelliFlash•Multi-gas versatility with one-button simplicity •Incredibly thin and lightweight, making itcomfortable to wearWear yellow. Work safe.Additional GasAlertMicroClip XT features:• IntelliFlash verifi es operation and compliance to both the user and supervisor • Tamper-proof, one button operation• Compatible with the Sampler motorized remote sampling pump • Equipped with internal vibrating alarm for high noise areas • Powered by a lithium polymer battery• Multi-language support in English, French, German, Spanish and Portuguese • Conveniently manage your fl eet using Fleet Manager II Standard features of BW products:• Continuous LCD shows real-time gas concentrations• Compact and lightweight design makes it comfortable to wear • Water-resistant• Simple automatic calibration procedure; compatible with BW MicroDock II automatic test and calibration station • Full function self-test of sensor, battery status, circuit integrity and audible/visual alarms on start up • Bright wide-angled visual alarm bars • Built-in concussion-proof bootDUE TO ONGOING RESEARCH AND PRODUCT IMPROVEMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.6642-1-EN© 2010 Honeywell International Ltd. All Rights Reserved.Corporate Headquarters2840 - 2 Avenue S.E. USA 1.888.749.8878 Middle East+971.4.450.5852 Latin America +55.11.3309.1030Calgary, AB, Canada T2A 7X9 Europe +44 (0)1295.700.300 S.E. Asia +65.6580.3468 Other Countries +1.403.248.9226Phone: +1.403.248.9226 France +33 (0) 442.98.17.70 China +86.10.6786.7305Toll free: 1.800.663.4164 Germany 49 (0) 2137.17.6522 Australia +61.3.9464.2770www.g a info@g a MicroDock II compatibleAuxillary fi lter kitIR connectivity kitFive unit cradlePRODUCT ACCESSORIESCarrying Accessories The slim and compact GasAlertMicroClip XT provides affordable protectionfrom atmospheric hazards. With IntelliFlash, this multi-gas detector offerscontinuous visual confi rmation of detector operation and compliance. Simpleone button operation offers ultimate ease of use and signifi cantly reduces timespent training the user. The GasAlertMicroClip XT is fully compatible with BW’sMicroDock II automatic test and calibration system.Wear yellow. Work safe.GA-PA-1-(XX)Power AdaptorEnsure your detector is charged and ready for use with the power adaptor.Simply attach the detector through the charging and IR communications portand wait for the battery icon on the LCD to show the battery is fully charged.Ships with detector. Specify plug/region version (-XX): North America (none),United Kingdom (-UK), Europe (-EU), China/Australia (-CN).GA-VPA-1Vehicle Power AdaptorCharge your detector easily anywhere you go with the vehicle power adaptor(CLA) cigarette lighter adaptor. Only 12V suitable. Simply attach the detectoror battery through the charging and IR communications port and wait for thebattery icon on the LCD to show that the battery is fully charged or the LED onthe battery to turn green.GA-PA-3Direct-Wire Power AdaptorConnect directly to a 12 or 24V power system with the 12-24 V DC direct wirepower adaptor. Simply attach the detector or battery through the charging andIR communications port and wait for the battery icon on the LCD to show thatthe battery is fully charged or the LED on the battery to turn green.MC2-C01-MC5Multi-Unit Cradle ChargerSimultaneously charge fi ve detectors or batteries with the multi-unit cradlecharger. Simply slide detectors or batteries into the charger and wait for thebattery icon on the LCD to show the battery is fully charged or the LED on thebattery to turn green.GA-PA-1-MC5Multi-Unit Power AdaptorSimultaneously charge fi ve detectors or batteries with the multi-unit poweradaptor. Simply attach the detector or battery through the charging and IRcommunications port and wait for the battery icon on the LCD to show that thebattery is fully charged or the LED on the battery to turn green.GASALERTMICROCLIPXTACCESSORIESWear yellow. Work safe.GA-USB1-IRIR Connectivity KitThe IR connectivity kit easily connects through the charging and IR communications port for data downloads and access to instrument set-up options.Fleet ManagementFleet Manager IIFleet Manager II enables users to download information directly from theGasAlertMicroClipXT or the MicroDock II. Data storage and analysis is made easy.MC-AF-K1 / MC-AF1 / MC-SS-AF-K1Auxiliary Filter Kit Easily attaches in the fi eld to protect the internal fi lter.MC-TC-1Test Cap and HoseEasily deliver gas to sensor ports during remote sampling, calibration or bump testing with the test cap and hose. The test cap comes with a 1 ft./0.3 m hose.MC-AS01Manual Aspirator PumpFor remote sampling; complete with probe, hose, aspirator pump and adapter cap.D4-WT-1Hydrophobic Filter ReplacementThe Hydrophobic Filter Replacement can be easily inserted into the GasAlertMicroClip XT to prevent moisture from entering the detector. Comes in kits of 5, 50 or 100.HOSE 1-10 / 2-10 / 1-20 / 2-20 / 1-65 / 2-65Sampling HoseCollect samples from a safe distance with this sampling hose. You can connect the sampling hose to a manual aspirated or motorized sampling pump, which connects to your detector.GA-PROB1-1Sample ProbeThe Sample Probe (1 ft./0.3 m) is ideal for pick hole sampling or sampling hard to reach places. The particulate fi lters and hydrophobic barrier prevents moisture and debris from entering the detector.G4-PROB-FIL-K1Filter and Gaskets Replacement for GA-PROB1-1Replacement Hydrophobic Filters (1.0um), Particulate Filters and Gaskets for use with the Sample Probe to prevent moisture and particulates from entering the detector.G A S A L E R T M I C R O C L I P X T A C C E S S O R I E SPRODUCT ACCESSORIESMC2-SS / MC2-SS-K1Replacement Sensor ScreensEnsure that you are getting a true reading on your gas detector by replacing thesensor screen. The sensor screen prevents dirt and dust from entering the sensor.After use, the sensor screen can get clogged, affecting the readings on yourgas detector.SR-TOX-MC-DUM / SR-DUMM1 / SR-W-MC-DUMDummy SensorsIf your multi-gas detector is confi gured to monitor for less than four gases, thesedummy sensor can fi ll the extra spots.Replacement SensorsReplacement Sensors Available for all Compatible GasesReplacement H2S, CO, O2 and combustible sensors make detectormaintenance easy.DUE TO ONGOING RESEARCH AND PRODUCT IMPROVEMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Corporate Headquarterswww.ga info@ga Sensor Spares and ReplacementsWear yellow. Work safe.• GasAlertMicroClip XT • Charger wall plug• Calibration cap and tubing• Manual, materials booklet and technical reference guide• Leather carrying case • IR connectivity kit • 0.5 LPM regulator• 3 ft./1 m calibration hose with quick connect• 10 ft./3 m sampling hose with quick connect • Sampling probe• Hard-sided carrying case with lid insert pockets and foam case insertWith theGasAlertMicroClip XT ’s automatic test andcalibration system, power options to outlast your shift, one-button simplicity and IntelliFlash™ that provides continuous visual confi rmation of detector operation and compliance,multi-gas detection is made simple.Choose any sensor combination for yourGasAlertMicroClip XT multi-gas detector, which comes with a battery charger for your specifi c region. A variety of accessories and spares are available to compliment your detector and suit your application, such as confi ned space kits, carrying accessories, power options, docking station systems and sampling/testing equipment.Order SheetGASALERTMICROCLIPXTORDERSHEETNote: For a complete list of GasAlertMicroClip XT configurations please consult customer service.Wear yellow. Work safe.*For regions outside North America add to the end of the order number: “-EU” for Europe, “-UK” for United Kingdom and “-AU” for Australia/China.G A S A L E R T M I C R O C L I P X T O R D E R S H E E TPlease note that prices and specifi cations are subject to change without notice. In the event a price is published incorrectly, BW Technologies reserves the right to sell the item at the correct (actual) price.G A S A L E R T M I C R O C L I P X T O R D E R S H E E TCorporate Headquarters www.g a info@g a 。
加拿大BWM5五合一气体检测仪
![加拿大BWM5五合一气体检测仪](https://img.taocdn.com/s3/m/742abf494b73f242336c5fbd.png)
Gas Alert Micro5系列保护自己:GasAlertMicro 5 最多可同时监控和显示 5 种有害气体。
GasAlertMicro 5 适用于各种应用,具有多种选择的现场用户设定选项,提供标准的有毒气体模式、检测 VOC 的PID 模式或 CO2 检测的 IR 模式。
使用密码功能,防止未经授权对仪器设置进行修改。
GasAlertMicro 5 可兼容BW 的MicroDock II 自动测试和校准系统,具有无与伦比的多功能性、性能和整体价值。
多种气体探测器:VOCs、CO2、LEL、H2S、CO、O2、SO2、PH3、NH3、NO2、HCN、Cl2、ClO2、O3•最多可同时测量 5 种有害气体• 完全自定义,适合于任何应用• 在现场可迅速从扩散模式切换到可选的连体泵传感器:GasAlertMicro 5 有 3 种模式:有毒/电化、PID(用于VOC)或 IR(用于 CO2)。
有关可用传感器配置的更多信息,请与BW Technologies 联系,或参考最新 BWTechnoliges 报价单中的 GasAlertMicro 5 订购和定价信息电化和催化珠型传感器可用于:H2S 、CO、 O2、SO2 、Cl2 、ClO2、NH3 、PH3 、HCN、NO2、O3、可燃气体 (LEL)光电离传感器可用于检测挥发性有机化合物 (VOC)。
光电离传感器可用于检测挥发性有机化合物 (VOC)。
1 注意:由于主板和传感器配置的缘故,GasAlertMicro 5模式不可互换(例如,PID 传感器不可用于 IR 配置的设备)。
2 扩散和泵的配置均与 MicroDock II- 自动冲击测试和校准系统兼容BW 产品的标准功能:• 不间断 LCD 显示实时气体浓度• 防水• 自动校准程序;与 BW MicroDock II 自动测试和校准站兼容• 启动时进行传感器、电池状态、电路完好性和声音/视觉警报的全功能自检• 明亮的广角可视警报光柱• 内置式防震外罩其它 GasAlertMicro 5 特点:•可用于远程采样的内置电动泵•配有内置振动警报,适用于高噪声区•两种供电方式:AA 碱性电池,或者可即时更换的充电电池组•多语言支持,包括英语、法语、德语、西班牙语和葡萄牙语选件与附件:•连体泵和电池、充电器•受限空间工具套装•皮套•可折叠采样、探头(本资料素材和资料部分来自网络,仅供参考。
GasAlertMicro 5 系列便携式气体检测仪器说明书
![GasAlertMicro 5 系列便携式气体检测仪器说明书](https://img.taocdn.com/s3/m/740abeb39f3143323968011ca300a6c30c22f190.png)
VOCs, CO 2, LEL, H 2S, CO, O 2, SO 2, PH 3, NH 3, NO 2, HCN, Cl 2, ClO 2, O 3Protect yourselfCompact and lightweight, GasAlertMicro 5 Series instruments areavailable in diffusion or pumped instruments. The portable gas detectors simultaneously monitors and displays up to five potential atmospheric hazards. The GasAlertMicro 5 PID model also identifies PID detectable VOCs, while the GasAlertMicro 5 IR uses an NDIR sensor to monitorCO 2 levels. Adaptable to a variety of applications, GasAlertMicro 5 Series instruments have an extensive selection of user-settable field options. Use the passcode function to prevent unauthorized modifications of the instrument’s settings. Compatible with BW’s MicroDock II automatic test and calibration system, GasAlertMicro 5 Series instruments are unparalleled in their versatility, performance and overall value.Standard Package Contents• D etector complete with specified sensor(s), stainless steel alligator clip and concussion-proof housing• Rechargeable battery pack or alkaline pack with three AA batteries • Cradle charger and wall outlet charging adaptor (with rechargeable battery option)• Sample probe (with motorized pump option)• Screwdriver• Calibration/test adaptor and hose • Manual• Multi-language CD manual General SpecificationsSize 5.7 x 2.9 x 1.5 in. / 14.5 x 7.4 x 3.8 cm Weight 13.1 oz. / 370 gOperating temperature -4 to +122°F / -20 to +50°C14 to +104°F / -10 to +40°C (PID)Typical battery life 20 hours (15 hours PID/IR)**Based on a 5-gas instrument in diffusion mode at 68ºF / 20ºCCertifications and approvalsClass I, Div. 1, Gr. A, B, C, D American Bureau of Shipping (Toxic and PID models)ATEX: X g II 1 G Ga Ex ia IIC T4*X g II 2 G (IR model only)Ex d ia IIC T4*IECEx: Ga Ex ia IIC T4* Ex d ia IIC T4* (IR model only)*Temperature codes may vary as a function of the batteries installed. Please see owner’s manual for a complete listing of compatible batteries and codes.WarrantyFull two year warranty including sensors (one year Cl 2, NH 3, O 3, ClO 2 and PID sensor)5612-15GasAlertMicro 5.....................................................................................50GasAlertMicro 5 PID ..............................................................................52GasAlertMicro 5 IR ................................................................................54GasAlertMicro 5 Series Accessories, Spares & Replacements ............56GasAlertMicro 5 Series Service Parts (60)GasAlertMicro 5 DetectorOrder NumberGasAlertMicro 5 Region CodesNote: Listed above are commonly ordered instrument configurations. To create a custom GasAlertMicro 5 detector, use the configurator table on the next page or contact BW Technologies for a copy of the electronic order number configurator.GasAlertMicro 5Pump versionGasAlertMicro 5Diffusion versionOrder Number ConfiguratorOrder number:For example, the order number for a GasAlertMicro 5 configured for O 2, %LEL, Cl 2, H 2S and CO and equipped with a rechargeable battery pack and cradle charger, motorized sampling pump, yellow housing and North American powerconnectivity would be M5-XWCY-R-P-D-Y-N-00.*Note: Some gases (e.g. SO 2 and NH 3) cannot be combined in the same GasAlertMicro 5 configuration. Please checkwith Customer Service for specific availability.†Note: HCN can only be ordered in the Toxic 1 location when the Duo-Tox (CO/H 2S) sensor is ordered in theToxic 2 location. In all other configurations, HCN must be ordered in the Toxic 2 location.Note: Listed above are commonly ordered instrument configurations. To create a custom GasAlertMicro 5 PID detector, use the configurator table on the next page or contact BW Technologies for a copy of the electronic order number configurator.GasAlertMicro 5 PIDPump versionGasAlertMicro 5 PIDDiffusion versionOrder Number ConfiguratorOrder number:For example, the order number for a GasAlertMicro 5 PID configured for O 2, %LEL, VOCs, H 2S and CO and equipped with a rechargeable battery pack and cradle charger, motorized sampling pump, yellow housing and North Americanpower connectivity would be M5PID-XWQY-R-P-D-Y-N-00.*Note: Some gases cannot be combined in the same GasAlertMicro 5 configuration. Please check with CustomerService for specific availability.GasAlertMicro 5 IR DetectorOrder NumberGasAlertMicro 5 IR Region CodesNote: Listed above are commonly ordered instrument configurations. To create a custom GasAlertMicro 5 IR detector, use the configurator table on the next page or contact BW Technologies for a copy of the electronic order number configurator.Gas LegendGasAlertMicro 5 IRPump versionGasAlertMicro 5 IRDiffusion versionOrder number:For example, the order number for a GasAlertMicro 5 IR configured for O 2, %LEL, CO 2, H 2S and CO and equipped with a rechargeable battery pack and cradle charger, motorized sampling pump, yellow housing and North American powerconnectivity would be M5IR-XWBY-R-P-D-Y-N-00.*Note: Some gases cannot be combined in the same GasAlertMicro 5 configuration. Please check with CustomerService for specific availability.Order Number ConfiguratorDeluxe Confined Space KitM5-CK-DLConcussion-Proof BootGA-BM5-2For GasAlertMicro 5 Seriespumped unitsCarrying HolsterGA-HM5Fits securely on belt Confined Space Kits Order Number Carrying & Protective Accessories Order NumberConcussion-Proof BootGA-BM5-1For GasAlertMicro 5 Seriesdiffusion unitsSampling & Testing Equipment Order NumberNote: For complete list of Sampling & Testing Equipment, see the Sampling Equipment section.ReplacementTest Cap and HoseM5-TC-1Pump ModuleM5-PUMPReplacementDiffusion CoverM5-DC-1Manual Aspirator PumpGA-AS02For remote sampling; complete withprobe, hose and aspirator pumpAuxiliary Pump Filter withHose ConnectorM5-QCONN-K1Auxiliary Pump FilterM5-AF-K2 / M5-AF-K2-100Kit of 5 or 100, for legacyGeneration 1 pump modules onlyAuxiliary Pump FilterM5-AF-K3 / M5-AF-K3-100Kit of 5 or 100, for Generation 2pump modulesPower Accessories Order Number *Note: Battery packs and chargers should be used with the new version GasAlertMicro 5 Series gas detectors (red circuit boards).MicroDock IIOrder Number Cradle ChargerM5-C01Cradle charger for rechargeable battery packs(can charge battery pack with or without detector attached)Vehicle Adaptor 12 V dcGA-V-CHRG4Vehicle adaptor cable for use with cradle charger (M5-C01)Cradle Charger Kit with BatteryM5-C01-BAT08 / M5-C01-BAT08BComplete with charger and rechargeable battery packAlkaline Battery PackM5-BAT0501/M5-BAT0501B M5-BAT0502/M5-BAT0502BRechargeable Battery PackM5-BAT08/M5-BAT08B5062-26-NCL-EN59PID Cleaning KitM5PID-CLN-K1For PID sensorsReplacement Electrode StackM5PID-ES-1For PID sensorsReplacement 10.6 eV PID LampRL-PID10.6For PID sensorsReplacement Sensor Screens Order Number Replacement SensorsOrder Number Note: All sensors come with a 2 year warranty unless marked with an asterisk (*), denoting 1 year warranty.†Advisory: Detectors are equipped on a standard basis with SR-W04 combustible sensors. This sensor includes a heavy duty silicone filter that make it ideal for use in environments that have known sources of silicone or vapors containing silicon. The SR-W04 silicone filter equipped sensor should not be used when monitoring diesel, kerosene, jet fuel or other heavy hydrocarbon vapors with flashpoint temperatures above 38°C (100°F).Replacement IR SensorSR-B04Replacement PID SensorSR-Q07www.CanarySense .ca Shop for Gas products online at:1.800.561.8187605062-26-NCL-EN Note: Please refer to the instrument’s documentation (shipped with the product or available at ) for complete instructions on common service procedures. Improper servicing or maintenance may affect warranty eligibility. Honeywell assumes no liability for damages resulting from improper servicing or maintenance.www.CanarySense.caShop for Gas products online at: 1.800.561.81875062-26-NCL-EN61Note: Please refer to the instrument’s documentation (shipped with the product or available at ) for complete instructions on common service procedures. Improper servicing or maintenance may affect warranty eligibility. Honeywell assumes no liability for damages resulting from improper servicing or maintenance.LegendService PartsOrder Number How to Replace a Sensor1. With detector OFF , use No. 1 Phillips screwdriver to remove2 screws (G) from back enclosure (F) on either side of the belt clip 2. Lift diffusion cover (A) or pump module straight up3. Remove sensor (O-R) by pulling straight up from PCB (E)4. Insert new sensor (O-R) into PCB (E)5. Replace diffusion cover (A) or pump module6. Replace 2 screws (G) in back enclosure (F) andhand-tighten until firmHow to Replace the Sensor Screen1. With detector OFF , use No. 1 Phillips screwdriver to remove2 screws (G) from back enclosure (F) on either side of the belt clip 2. Lift diffusion cover (A) or pump module straight up3. Remove sensor screen (B) by pulling it straight up fromdiffusion cover (A) or pump module4. Insert sensor screen (B) into diffusion cover (A) orpump module5. Replace diffusion cover (A) or pump module6. Replace 2 screws (G) in back enclosure (F) andhand-tighten until firmwww.CanarySense .ca Shop for Gas products online at:1.800.561.8187。
GasAlertMicro 5 PID 气体检测仪说明书
![GasAlertMicro 5 PID 气体检测仪说明书](https://img.taocdn.com/s3/m/7f30bf70ef06eff9aef8941ea76e58fafbb0456c.png)
sEmail:***************222332223五合一气体检测仪保障您的安全S 与同类仪器相比更为小巧,重量减轻一半以上S 连体式外壳,既防震又防水S LCD 显示屏可同时持续显示五种气体浓度S 测量 0 - 1000 ppm 的 VOC (挥发性有机化合物) S 连体采样泵可用于远距离采样S 两种供电方式:AA 碱性电池,或者可随地更换的充电电池组S 报警时发出95分贝高音和两段明亮广角警报灯S 内置振动报警器,适用于非常嘈杂环境S 支援多国语言:英文、法文、德文、西班牙语、西班牙文和葡萄牙文S 三种背景光模式可供选择:标准模式-弱光下(自动),报警时(自动),和需要时激活;报警模式-报警下激活,需要时再次激活;秘密模式S 四个警报级别:所有气体的瞬时低限和高限警报;VOC 和有毒气体的 TWA (时间加权平均值)和 STEL (短期曝露极限)警报S 简单的自动校准程序;与 BW MicroDock II 自动测试和校准站兼容S 记录和指令下显示TWA ,STEL 和气体暴露最大值S 用户可选择的现场选项包括:PID/可燃气体修正因数、语言选择、提示音、校准气体浓度、设置 TWA/STEL 计算选项、设置校准到期日、密码保护、锁定警报、“SAFE”显示功能、静默模式以及选择某些气体的 ppm 精度(如将 SO 2 的测量精度设为 0.1 ppm )S 全功能自检包括:传感器、电池和电路的完整性;听觉/视觉报警订购信息GasAlertMicro 5 PID 配有传感器(需指定)、传感器盒盖(用于扩散采样模式)、电池(需指定)、不锈钢鳄鱼夹、校准盖/软管、2 个额外的电极组、说明书(本地语言)和交互式培训光盘。
一旦交付,即可投入使用。
电池/充电器的选择三节AA 碱性电池可充电电池组和桌式/墙式充电器选配用户下载数据记录器包括32MB MMC 卡、软件和一个用于MicroDock II 自动校准测试的红外端口选配采样泵包括检测仪、标准附件、连体式电动泵和泵盖(已装好)、12 英寸/30 厘米长的采样软管以及带有疏水栅(疏水阀)和微粒过滤器的采样探头、5 英尺/1.5 米长的采样管、5 个备用的微粒过滤器和 1 个备用的疏水阀过滤器。
Tekelec EAGLE 5集成通信系统维护手册说明书
![Tekelec EAGLE 5集成通信系统维护手册说明书](https://img.taocdn.com/s3/m/bd53abd182d049649b6648d7c1c708a1284a0ac7.png)
Tekelec EAGLE® 5 Integrated Signaling SystemMaintenance Manual910-5272-001 Revision BMay 2008Copyright 2008 TekelecAll Rights Reserved.Printed in U.S.A.NoticeInformation in this documentation is subject to change without notice. Unauthorized use, copying, or translation of this documentation can result in civil or criminal penalties.Any export of Tekelec products is subject to the export controls of the United States and the other countries where Tekelec has operations.No part of this documentation may be reproduced, translated, or transmitted in any form or by any means, electronic or mechanical, including photocopying or recording, for any purpose without the express written permission of an authorized representative of Tekelec.Other product names used herein are for identification purposes only, and may be trademarks of their respective companies.RoHS 5/6 - As of July 1, 2006, all products that comprise new installations shipped to European Union member countries will comply with the EU Directive 2002/95/EC "RoHS" (Restriction of Hazardous Substances). The exemption for lead-based solder described in the Annex will be exercised. RoHS 5/6 compliant components will have unique part numbers as reflected in the associated hardware and installation manuals.WEEE - All products shipped to European Union member countries comply with the EU Directive 2002/96/EC, Waste Electronic and Electrical Equipment. All components that are WEEE compliant will be appropriately marked. For more information regarding Tekelec's WEEE program, contact your sales representative.TrademarksThe Tekelec logo, EAGLE, G-Flex, G-Port, IP7, IP7 Edge, and IP7 Secure Gateway are registered trademarks of Tekelec. TekServer, A-Port, and V-FLEX are trademarks of Tekelec. All other trademarks are the property of their respective owners. PatentsThis product is covered by one or more of the following U.S. and foreign patents:U.S. Patent Numbers:5,732,213; 5,953,404; 6,115,746; 6,167,129; 6,324,183; 6,327,350; 6,456,845; 6,606,379; 6,639,981; 6,647,113; 6,662,017; 6,735,441; 6,745,041; 6,765,990; 6,795,546; 6,819,932; 6,836,477; 6,839,423; 6,885,872; 6,901,262; 6,914,973; 6,940,866; 6,944,184; 6,954,526;6,954,794; 6,959,076; 6,965,592; 6,967,956; 6,968,048; 6,970,542; 6,987,781; 6,987,849; 6,990,089; 6,990,347; 6,993,038; 7,002,988; 7,020,707; 7,031,340; 7,035,239; 7,035,387; 7,043,000; 7,043,001; 7,043,002; 7,046,667; 7,050,456; 7,050,562; 7,054,422; 7,068,773; 7,072,678; 7,075,331; 7,079,524; 7,088,728; 7,092,505; 7,108,468; 7,110,780; 7,113,581; 7,113,781; 7,117,411; 7,123,710; 7,127,057; 7,133,420; 7,136,477; 7,139,388; 7,145,875; 7,146,181; 7,155,206; 7,155,243; 7,155,505; 7,155,512; 7,181,194; 7,190,702; 7,190,772; 7,190,959; 7,197,036; 7,206,394; 7,215,748; 7,219,264; 7,222,192; 7,227,927; 7,231,024; 7,242,695; 7,254,391; 7,260,086; 7,260,207; 7,283,969; 7,286,516; 7,286,647; 7,286,839; 7,295,579; 7,299,050; 7,301,910; 7,304,957; 7,318,091; 7,319,857; 7,327,670Foreign Patent Numbers:EP1062792; EP1308054; EP1247378; EP1303994; EP1252788; EP1161819; EP1177660; EP1169829; EP1135905;EP1364520; EP1192758; EP1240772; EP1173969; CA2352246Ordering InformationTo order additional copies of this document, contact your Tekelec Sales Representative.Table of Contents Chapter 1. Introduction ..................................................................................................... 1-1Overview .................................................................................................................................... 1-1Scope and Audience ................................................................................................................... 1-2Related Publications ................................................................................................................... 1-2Documentation Availability, Packaging, and Updates ............................................................... 1-2Locate Product Documentation on the Customer Support Site .................................................. 1-3Admonishments and Conventions .............................................................................................. 1-4Customer Care Center ................................................................................................................ 1-4Problem Report (PR) ........................................................................................................... 1-5Emergency Response .......................................................................................................... 1-6Hardware Repair and Return ...................................................................................................... 1-6Maintenance Strategy ................................................................................................................. 1-9Application Self Recovery .................................................................................................. 1-9System Maintenance Software Intervention ........................................................................ 1-9Maintenance Personnel Intervention ................................................................................. 1-10System Maintenance Log ......................................................................................................... 1-10 Chapter 2. Preventive Maintenance ................................................................................. 2-1Introduction ................................................................................................................................ 2-1Maintaining the Fuse and Alarm Panel ...................................................................................... 2-21U FAP P/N 870-2804-01 ................................................................................................... 2-33U FAP ................................................................................................................................ 2-8MO Removable Cartridge Description ..................................................................................... 2-15Removable Cartridge Handling Procedures ............................................................................. 2-17Daily Procedures ....................................................................................................................... 2-18System Reports Analysis ................................................................................................... 2-19Reports Description ........................................................................................................... 2-19File Transfer for LNP and INP Measurements ................................................................. 2-20Weekly Procedures ................................................................................................................... 2-21Printer Inspection .............................................................................................................. 2-22Remote Access Verification .............................................................................................. 2-22Monthly Procedures .................................................................................................................. 2-23FAP Load Balance Verification (PN 870-0243-XX only) ................................................ 2-24Change the Fan Tray Filter ................................................................................................ 2-28Changing the Air Supply Filter ......................................................................................... 2-28Cleaning Printer ................................................................................................................. 2-29Fuse Spares Inventory ....................................................................................................... 2-30Wrist Strap Test ................................................................................................................. 2-30Quarterly Procedures ................................................................................................................ 2-31 910-5272-001 Revision B, May 2008iTable of Contents Maintenance ManualPreventing Dust Buildups .................................................................................................. 2-31Rectifier Voltage Inspection/Recording ............................................................................ 2-32 Semi-Annual Procedures .......................................................................................................... 2-32Chapter 3. Corrective Maintenance ................................................................................. 3-1 Introduction .............................................................................................................................. 3-19System Alarm Levels ................................................................................................................ 3-20 Critical ............................................................................................................................... 3-20Major ................................................................................................................................. 3-20Minor ................................................................................................................................. 3-20 Trouble Detection ..................................................................................................................... 3-20 Audible Alarms ................................................................................................................. 3-20Visual Alarms .................................................................................................................... 3-21MDAL LEDs ..................................................................................................................... 3-21Alarm LEDs on the Fuse and Alarm Panel (FAP) ............................................................ 3-22Alarms appearing on a terminal screen ............................................................................. 3-25Alarms on Application Cards ............................................................................................ 3-26End Cabinet Alarm Indicators ........................................................................................... 3-26Event/Error Messages ........................................................................................................ 3-26IMT Bus States .................................................................................................................. 3-26IMT System Alarm Level Determination ......................................................................... 3-27 Unsolicited Alarm Messages (UAM) ....................................................................................... 3-28Unsolicited Information Messages ........................................................................................... 3-43Output Messages ....................................................................................................................... 3-56UAM/UIM Changes ................................................................................................................. 3-57 EAGLE 5 ISS Release 33.0 UAM/UIM Changes ............................................................. 3-57EAGLE 5 ISS Release 34.0 UAM/UIM Changes ............................................................. 3-63EAGLE 5 ISS Release 34.3 UAM/UIM Changes ............................................................. 3-66EAGLE 5 ISS Release 35.0 UAM/UIM Changes ............................................................. 3-67EAGLE 5 ISS Release 35.1 UAM/UIM Changes ............................................................. 3-71EAGLE 5 ISS Release 36.0 UAM/UIM Changes ............................................................. 3-71EAGLE 5 ISS Release 37.0 UAM/UIM Changes ............................................................. 3-72EAGLE 5 ISS Release 37.5 UAM/UIM Changes ............................................................. 3-73 Alarm Clearing Procedures ...................................................................................................... 3-75Retrieve Trouble Report ........................................................................................................... 3-75Hourly Status Message Reports ................................................................................................ 3-76Maintenance System Event Logs ............................................................................................. 3-80Obituaries .................................................................................................................................. 3-82Terminal Not Responding ........................................................................................................ 3-82Printer Not Working ................................................................................................................. 3-84Modem Not Working ................................................................................................................ 3-85Remove Removable Cartridge Stuck in Drive on MDAL ....................................................... 3-85Link Maintenance ..................................................................................................................... 3-87 Link Fault Sectionalization ............................................................................................... 3-87Hardware Configuration .................................................................................................... 3-88Test Indicators ................................................................................................................... 3-90Test Report ........................................................................................................................ 3-91LFS Test Details ................................................................................................................ 3-91 ii910-5272-001 Revision B, May 2008Maintenance Manual Table of ContentsLink Maintenance Enhancements ..................................................................................... 3-93 Power Down of In-Service System .......................................................................................... 3-99Power Up of the System ......................................................................................................... 3-101UAM and UIM Troubleshooting Procedures ......................................................................... 3-101 0001 - Card has reset ....................................................................................................... 3-1020002 - Card is not running approved GPL ...................................................................... 3-1020003 - Alarm cleared for GPL ......................................................................................... 3-1090004 - Card is running non-activated GPL ..................................................................... 3-1090005 - Alarm cleared running non-activated GPL .......................................................... 3-1100008 - Active MASP has become isolated ...................................................................... 3-1100009 - MASP became active ........................................................................................... 3-1100010 - MASP became standby ........................................................................................ 3-1110011 - Entering forced simplex mode ............................................................................. 3-1110013 - Card is isolated from the system .......................................................................... 3-1120014 - Card is present ...................................................................................................... 3-1130018 - Exiting forced simplex mode ............................................................................... 3-1140021 - Clock A for card failed, B normal ........................................................................ 3-1140022 - Clock B for card failed, A normal ........................................................................ 3-1150023 - Clocks A and B for card failed ............................................................................. 3-1160024 - Clock A for card normal ...................................................................................... 3-1160025 - Clock B for card normal ....................................................................................... 3-1170026 - Clocks A and B for card normal .......................................................................... 3-1170033 - Card database has been corrected ........................................................................ 3-1170034 - Card database is inconsistent ............................................................................... 3-1180035 - Card database is corrupted ................................................................................... 3-1200036 - Card backup database has been corrected ............................................................ 3-1220037 - Card backup database is inconsistent ................................................................... 3-1220038 - Card backup database is corrupted ....................................................................... 3-1230039 - GPL has been corrected ....................................................................................... 3-1230040 - GPL is corrupted .................................................................................................. 3-1240041 -LSMS bulk load required ...................................................................................... 3-1240042 - LSMS bulk load complete .................................................................................... 3-1240043 - Incorrect feature configuration ............................................................................. 3-1250044 - Real time clock battery low ................................................................................. 3-1250045 - Real time clock battery restored ........................................................................... 3-1250046 - Terminal enabled .................................................................................................. 3-1260047 - Card type not valid for application ...................................................................... 3-1260048 - Terminal failed ..................................................................................................... 3-1260051 - TSC sync is in simplex mode ............................................................................... 3-1270052 - TSC sync feature is available ............................................................................... 3-1270053 - Standby TDM failure ........................................................................................... 3-1270054 - Standby TDM failure cleared ............................................................................... 3-1280055 - Persistent device state tbl corrupt ......................................................................... 3-1280056 - Persistent device state tbl diff version .................................................................. 3-1290057 - Persistent device state tbl corrected ..................................................................... 3-1290058 - Critical customer trouble detected ....................................................................... 3-1290059 - Major customer trouble detected .......................................................................... 3-1300060 - Minor customer trouble detected ......................................................................... 3-130 910-5272-001 Revision B, May 2008iiiTable of Contents Maintenance Manual0061 - Customer trouble detected ................................................................................... 3-1300062 - Customer trouble cleared ..................................................................................... 3-1310063 - Critical holdover clock trbl detected .................................................................... 3-1310064 - Major holdover clock trouble detected ................................................................ 3-1310065 - Minor holdover clock trouble detected ................................................................ 3-1310066 - Holdover clock trouble cleared ............................................................................ 3-1320077 - Card temperature is critical lvl:T2 ....................................................................... 3-1320078 - Card temperature exceeds nominal lvl:T1 ........................................................... 3-1340079 - Card temperature again at nominal levels ............................................................ 3-1360082 - Alarm in Fuse panel ............................................................................................. 3-1360083 - Fuse Panel alarm has cleared ............................................................................... 3-1370084 - IP Connection Unavailable .................................................................................. 3-1380085 - IP connection available ........................................................................................ 3-1410086 - IP Connection Congested ..................................................................................... 3-1410087 - IP Connection manually removed ........................................................................ 3-1420088 - Clocks A and B TSCs are out of sync .................................................................. 3-1420089 - Clocks A and B TSCs are resynchronized ........................................................... 3-1430092 - MDAL not responding ......................................................................................... 3-1430093 - MDAL alarm cleared ........................................................................................... 3-1430096 - Card has been reloaded ........................................................................................ 3-1440097 - IMT allowed ......................................................................................................... 3-1440098 - IMT inhibited ....................................................................................................... 3-1440099 - Incompatible HW for provisioned slot ................................................................. 3-1450102 - Motherboard BIP invalid ..................................................................................... 3-1450103 - Motherboard BIP valid ......................................................................................... 3-1460106 - IMT Bus alarm cleared ........................................................................................ 3-1460107 - Minor IMT failure detected .................................................................................. 3-1460108 - Major IMT failure detected .................................................................................. 3-1480109 - All IMT System level alarms cleared .................................................................. 3-1510110 - Failure detected on one IMT bus ......................................................................... 3-1510111 - Failure on both IMT A and IMT B ...................................................................... 3-1530112 - Major failures detected on both IMTs .................................................................. 3-1530113 - Clock alarm(s) cleared ......................................................................................... 3-1540115 - Linkset IP TPS threshold exceeded ..................................................................... 3-1540116 - Link expected IP TPS threshold exceeded ........................................................... 3-1550118 - Linkset IP TPS normal ......................................................................................... 3-1550119 - Link IP TPS normal ............................................................................................. 3-1560128 - All clocks have failed ........................................................................................... 3-1560130 - Card successfully loaded with data ...................................................................... 3-1560132 - Loading failed: table not found ............................................................................ 3-1570133 - Loading failed: data read Error ............................................................................ 3-1570134 - Loading failed: bad checksum returned ............................................................... 3-1580135 - Loading failed: GPL load timeout ....................................................................... 3-1580136 - Loading failed: data load timeout ........................................................................ 3-1580137 - Loading failed: invalid GPL ................................................................................ 3-1590138 - Loading failed: GPL format error ........................................................................ 3-1590139 - Loading failed: disk read prep error ..................................................................... 3-1590140 - Loading failed: disk read response error .............................................................. 3-160 iv910-5272-001 Revision B, May 2008Maintenance Manual Table of Contents0141 - Loading failed: disk read failed ........................................................................... 3-1600142 - System release alarm cleared ............................................................................... 3-1600143 - System release GPL(s) not approved ................................................................... 3-1600144 - System release version unknown ......................................................................... 3-1610145 - HS Clock A for card failed, B normal ................................................................. 3-1610146 - HS Clock B for card failed, A normal ................................................................. 3-1620147 - High Speed Clocks A and B for card failed ......................................................... 3-1630148 - High Speed Clock A for card normal ................................................................... 3-1640149 - High Speed Clock B for card normal ................................................................... 3-1640150 - STPLAN is available ........................................................................................... 3-1650151 - STPLAN capacity normal,card(s) abnormal ........................................................ 3-1650152 - LIM(s) have been denied STPLAN service ......................................................... 3-1660153 - STPLAN not available ......................................................................................... 3-1660154 - STPLAN is removed ............................................................................................ 3-1670155 - STPLAN connection unavailable ......................................................................... 3-1670156 - STPLAN connection available ............................................................................. 3-1680157 - X25 logical channels available ............................................................................ 3-1680158 - X25 no logical channels available ....................................................................... 3-1680159 - High Speed Clocks A and B for card normal ....................................................... 3-1690160 - 1116-S clock failed .............................................................................................. 3-1690161 - 1116-P clock failed .............................................................................................. 3-1690162 - 1116-P, 1116-S clocks failed ............................................................................... 3-1700163 - 1114-S clock failed .............................................................................................. 3-1700164 - 1114-S, 1116-S clocks failed ............................................................................... 3-1710165 - 1114-S, 1116-P clocks failed ............................................................................... 3-1710166 - 1114-S, 1116-P, 1116-S clocks failed .................................................................. 3-1720167 - 1114-P clock failed .............................................................................................. 3-1730168 - 1114-P, 1116-S clocks failed ............................................................................... 3-1730169 - 1114-P, 1116-P clocks failed ............................................................................... 3-1740170 - 1114-P, 1116-P, 1116-S clocks failed .................................................................. 3-1740171 - 1114-P, 1114-S clocks failed ............................................................................... 3-1750172 - 1114-P, 1114-S, 1116-S clocks failed .................................................................. 3-1750173 - 1114-P, 1114-S, 1116-P clocks failed .................................................................. 3-1760174 - %full threshold reached -upload required ............................................................ 3-1770175 - LOGBUFROVFL-SECULOG - upload required ................................................ 3-1770176 - Stdby security log - upload required .................................................................... 3-1780177 - Security log exception cleared ............................................................................. 3-1780178 - Security log failed ................................................................................................ 3-1780179 - NDC Q.3 association is unavailable .................................................................... 3-1790180 - NDC Q.3 association is available ........................................................................ 3-1790181 - NDC Subsystem is not available .......................................................................... 3-1790182 - NDC Subsystem is available ................................................................................ 3-1810183 - 1116-SHS clock failed ......................................................................................... 3-1810184 - 1116-PHS clock failed ......................................................................................... 3-1820185 - 1116-PHS, 1116-SHS clocks failed ..................................................................... 3-1820186 - 1114-SHS clock failed ......................................................................................... 3-1830187 - 1114-SHS, 1116-SHS clocks failed ..................................................................... 3-1840188 - 1114-SHS, 1116-PHS clocks failed ..................................................................... 3-184 910-5272-001 Revision B, May 2008v。
bw复合气体检测仪
![bw复合气体检测仪](https://img.taocdn.com/s3/m/fb536fbd70fe910ef12d2af90242a8956becaa2a.png)
BW复合气体检测仪概述BW复合气体检测仪,是一款多功能气体检测仪,可同时测量多种气体浓度,用于矿井、化工等危险行业场所的气体检测。
该气体检测仪具有多种传感器,能够检测多种气体浓度,是一种功能齐全的气体检测仪,同时还具有声光报警、突发事件记录等功能。
功能多种气体浓度检测BW复合气体检测仪内置多个传感器,可同时测量氧气浓度、可燃气体浓度、有毒气体浓度等多种气体浓度。
气体浓度显示直观,用户可通过折线图及数字显示了解气体分布情况,从而采取相应的安全措施。
声光报警当气体浓度超过设定报警阈值时,BW复合气体检测仪将发出声光报警,提醒现场工作人员采取安全措施。
此报警可在安全警报系统与现场声光报警器中同步触发,有效保障人员生命安全。
突发事件记录BW复合气体检测仪内置了记录器,能够记录气体浓度变化的历史数据,当发生突发事件时,记录器可保存事件发生前的数据,作为事故调查的依据。
技术参数•测量范围:–氧气浓度:0~30%vol–可燃气体:0~100%LEL–有毒气体:0~100ppm•报警方法:声音、光线报警•电源:可充电锂电池•工作时间:持续工作时间不少于8小时•尺寸:高150mm x 宽80mm x 厚35mm•重量:约380g使用方法1.打开气体检测仪电源2.连接气体检测仪到气体管道或夹具上3.等待气体检测仪进行自检4.确认各项气体浓度显示正常5.监视气体浓度显示,防止出现危险情况注意事项1.气体检测仪定期检查和校正,保证精度稳定2.在进行气体检测时,保证仪器不受外界干扰,尽可能避免误判或误报3.气体检测仪使用过程中,注意安装与使用操作说明书中建议的附件与工具4.如有任何疑问,应咨询专业技术人员BW复合气体检测仪是一款功能强大、性能稳定的气体检测仪器,可广泛应用于各种化工、矿井等危险行业领域。
用户在使用气体检测仪时需严格遵守安全操作规定,确保工作人员的生命安全。
加拿大BW中国技术服务中心 GasAlertMax H2S, CO, O2, LEL 中文用户说明书
![加拿大BW中国技术服务中心 GasAlertMax H2S, CO, O2, LEL 中文用户说明书](https://img.taocdn.com/s3/m/58db086825c52cc58bd6bead.png)
自动关断告警 ............................................................. 23
校准并设定告警设定点........................................................ 24
准则 ...................................................................
BW Technologies 仅授权经销商将本保证提供给购买新的、未曾使用过的产品的最终用户。经销商无权以 BW Technologies 的名义来给予其它任何担保。保修服务仅限于从 BW Technologies 授权销售处所购买的产品,或购买者已付出 适当的BW Technologies 国际价格。在某一国家购买而需要在另一国家维修的产品,BW Technologies 保留向购买者征收维 修/更换零件进口费用的权利。
检测器维护.................................................................. 34
更换电池 ................................................................. 34
泵校准 ................................................................... 36
11/99
目录
标题
页
引言 .................................................................. ….. 1 与 BW Technologies 联系的方式 .............................................. 2 安全信息 - 首先阅读 ........................................................ 2 入门指南 ................................................................... 6 启动检测器 ................................................................. 10
加拿大BW气体检测仪GAXT系列用户手册10多种气体可选
![加拿大BW气体检测仪GAXT系列用户手册10多种气体可选](https://img.taocdn.com/s3/m/49fcb8f97c1cfad6195fa726.png)
• 快速调制音并闪烁 • ALARM 闪烁 • 快速震动
电量不足警报
• 每 5 秒钟响 1 声并闪烁,每分钟
快速震动 1 次(禁用置信响 音)。
• 无响声、闪烁、或震动(启用置信
响音)。
显示
7
GasAlert Extreme 快速参考指南
I
警报
自动关闭警报 (电量不足)
• 8 次响声、闪烁并震动 • 显示 LOW
产品; c) BW 有权要求客户提供购买凭证,如原始发票、销售契约或包装收据,以确定产品是否在保证期内。 客户同意本保证是客户唯一的赔偿条款,并代替其他全部保证,无论是明示的或暗示的、包括但不限于对于特殊目的适销性或适合性的任何 暗示保证。不论是由于违反本保证还是依据合同、侵权行为或信赖或任何其他理论,BW 对特殊、间接、偶然或附带产生的任何损坏或损 失,包括数据丢失,概不负责。 因为一些国家/地区或州不允许限制暗示保证的条款,或不允许排除或限制偶然或附带产生的损坏,因此本保证的限制和排除情况可能并不适 用于每位客户。如果本保证的任何规定被有资格的司法管辖法院认为无效或不可执行,将不会影响任何其他规定的有效性和可执行性。
BW Technologies 联系方式
美国 1-888-749-8878
加拿大 1-800-663-4164
欧洲 +44 (0) 1869 233004
中东 +971-4-8871766
中国 +852-2974-1783
澳大利亚 +61-7-3818-8244
其他国家 +1-403-248-9226
9
GasAlert Extreme 快速参考指南
维护
要保持检测仪良好的操作状态,请根据需要进行以下基本维 护:
加拿大BW M5多气检仪
![加拿大BW M5多气检仪](https://img.taocdn.com/s3/m/89a0e716eff9aef8941e06a2.png)
加拿大BW M5多气检仪GasAlertMicro 5最多可同时监控和显示 5 种有害气体,用于各种应用。
提供标准的易燃、有毒气体的检测。
使用密码功能,防止未经授权对仪器设置进行修改。
GasAlertMicro5 可兼容MicroDock II 自动测试和校准系统,具有优越的性能和整体价值。
完全自定义,适合于任何应用,在现场可迅速从扩散模式切换到可选的连体泵。
一、产品特点:✧不间断 LCD 显示实时气体浓度✧自动校准程序;与 BW MicroDock II 自动测试和校准站兼容✧启动时进行传感器、电池状态、电路完好性和声音/视觉警报的全功能自检✧明亮的广角可视警报光柱✧内置式防震外罩,配有内置振动警报,适用于高噪声区✧GasAlertMicro5有 2 种:催化燃烧式和电化学。
✧由于主板和传感器配置的缘故,GasAlertMicro 5 模式不可互换✧多语言支持,包括英语、法语、德语、西班牙语和葡萄牙语二、技术参数尺寸:5.7 x 2.9 x 1.5 英寸 / 14.5 x 7.4 x 3.8 厘米重量:13.1 盎司/370 克警报:视觉、振动和声音(95 分贝)- 低、高、STEL、TWA、OL(超限)采样方式:泵吸式(选配)电池:AA 碱性电池,或者可即时更换的充电电池组操作温度:-4 至+122°F / -20 至+50°C-14相对湿度(非冷凝):10% 至 -100% 相对湿度三、等级/认证IP66/67防护等级EMI/RFI:符合 EMC Directive 89/366/EECn Class I, Div. 1, Gr. A, B, C, DAmerican Bureau of Shipping ——有毒气体与 PID模式ATEX: II 1 G T4*;Ex ia IIC T4*IECEx: Ex ia IIC T4*四、订货信息:。
微型气体探测器5: GasAlertMicro 5说明书
![微型气体探测器5: GasAlertMicro 5说明书](https://img.taocdn.com/s3/m/f234557e11661ed9ad51f01dc281e53a58025133.png)
Multilingual support in English, French, German, Spanish and Portuguese. Large LCD display with user-selectable backlight. Four alert levels: low, high, TWA and STEL stealth modes. prehensive self-test confirms sensor, battery and circuit integrity, plus audible/visual alarms when activated.Protection where you need it.Features and benefits. Monitoring of volatile organic compounds (VOC), H2S, CO, O2, SO2, PH3, CI2, NH3, NO2, HCN, CIO2, O3 and flammable substances.
加拿大BW气体检测仪
![加拿大BW气体检测仪](https://img.taocdn.com/s3/m/7f57aa234b73f242336c5f30.png)
加拿大 BW 气体检测仪作为国际一线品牌产品,不仅具有优异的产品质量和性能,同
时与其他国际品牌相比,极具价格竞争优势。在冶金、石油化工、市政、造纸、消防等领域,
具有广阔的市场前景。
100
天
抛
弃
式
气
体
检
测
仪
H2S, C
GasAlertl00 对短期工作项目而言是一种实用且划算的解决方案.GasAlertl00 自启动之
可以将数据自动传输到计算机或 MicroDock ll 对接站模块中。无需接线!
GasAlertExtreme 延续了 BW Technologies 产品的优良传统,包括前沿的功能,无故障地 操作,经久耐用,
并且是当今市场上所有单一气体检测仪中使用价格最低的产品。 坚固耐用的 GasAlertMax XT 可以可靠地监测最多四种有毒气体,它将直观的单按钮界 面操作与 4 体化采样泵结合起来。防篡改、用户可调节选项允许自定义该仪器,以适合您的 应用。采用新的智能泵技术后,进入受限空间和远程采样的容易程度是前所未有的。最大程 度降低泵阻塞的几率,并提高了远程采样结果的精度。GasAlertMax XT 同 MicroDock II 自 动测试和校准系统完全兼容
加拿大 BW 公司是一家本部设在加拿大卡尔加里市的跨国集团公司,其服务和分销中心遍 布世界六大洲,BW 是一家在伦敦证券市场的上市公司,2006 年被 Honeywell 收购,与英国 CITY 传感器公司,共同作为霍尼韦尔集团的安全检测仪器 Safety 部门的主要企业。
BW 公司专业从事便携式和固定式工业安全气体检测仪的生产和销售,其便携式仪器以 专业化的设计、高质量、体积小巧美观、高性价比以及良好的服务在工业安全气体检测行业 为大家所称道。
M5气体检测仪使用说明
![M5气体检测仪使用说明](https://img.taocdn.com/s3/m/03e56ccc0c22590102029df0.png)
连接方式
使用方式
2.2 BW GAS ALERT MICRO 5 PID的使用步骤
2.3 BW GAS ALERT MICRO 5 PID的报警显示
2.4 BW GAS ALERT MICRO 5 PID的测量范围
2.5 BW GAS ALERT MICRO 5 PID的报警范围
四个警报级别:所有气体的瞬时低限、高限警报、VOC 和有毒; 气体的TWA(时间加权平均值)和STEL(短期曝露极限)警报; 连体式外壳,既防震又防水 报警时发出95分贝高音和两段明亮广角警报灯 内置振动报警器,适用于非常嘈杂环境 两种供电方式:AA 碱性电池, 或者可随地更换的充电电池组 测量0 - 1000 ppm
一般电池寿命 20 小时 15 小时 15 小时 AA 碱性电池 20 小时 15 小时 15 小时 充电电池 2 基于 5-气体检测仪在+68° F/+20° C 扩散模式时的运行时间,不同配置的检测仪或者在不同的环境 条件下,检测仪的电池寿命可能会增加或者减小 .
1.3 GASALERTMI CRO5 传感器
目录
1、GasAlertMicro 5 的简介 2、GasAlertMicro 5 PID的使用说明 3、GasAlertMicro5 PID的注意事项
1、GASALERTMICRO 5 的简介
1.1 GasAlertMicro 5 的特点
GasAlertMicro 5 最多可同时测量和显示 5 种有害气体。 GasAlert Micro5 适用于各种应用,具有多种选择的现场 用户设定选项,提供标准的有毒气体模式、检测 VOC 的 PID 模式或 CO2 检测的 IR 模式。 使用密码功能,防止未经授权对仪器设置进行修改。 GasAlertMicro5 可兼容BW 的 MicroDock II 自动测试 和校准系统,具有无与伦比的多功能 性、性能和整体价值。 完全自定义,适合于任何应用 在现场可迅速从扩散模式切换 到可选的连体泵,连体采样泵 可用于远距离采样
GasAlertMicro5中文使用说明书
![GasAlertMicro5中文使用说明书](https://img.taocdn.com/s3/m/65c5f7687e21af45b307a886.png)
A
G
• 要清除 TWA、 STEL 和最大 (MAX) 气体曝露浓度读数,同时按住 C 与 G,直到完成倒 计数。 • 要查看日期与时间、所有传感器的报警设置点 (TWA、 STEL、低与高 )、以及爆炸下限校 正系数 ( 选项 ),请按下 G。
H C
• 要使显示值减少,或向下滚动,按下 H。 • 要开始校准和设置警报设定值,请同时按住 C 与 H,直到完成倒计数。 • 要查看 TWA、 STEL 和最大气体浓度 (MAX),请按 C。 • 要确认收到锁定警报,按 C。
警报屏幕警报屏幕low启动振动器报警twa警报启动振动器报警high启动振动器报警stel警报启动振动器报警13gasalertmicro5pidir警报警报屏幕警报屏幕多种气体警报启动振动器报警超量程ol警报启动振动器报警传感器警报15秒响一声fail在失效的传感器上闪烁自动关闭警报临时启动振动器报警电量不足警报25秒响一声闪两下小心发出电池电量不足警报时请立即为电池充电
• 快速提示音 • 慢速闪烁 • L 与目标气体条状闪烁 • 启动振动器报警
HIGH ( 高警报 ) • 持续提示音 • 快速闪烁 • L 与目标气体条状闪烁 • 启动振动器报警
STEL 警报
• 持续提示音
• 快速闪烁
• L 与目标气体条状闪烁
• 启动振动器报警
12
GasAlertMicro 5/PID/IR
态( TWA STEL 查看 TWA STEL 值 (MAX)
自动传感器归零显示
5
GasAlertMicro 5/PID/IR
快速参考指南
钮
钮 说明 • 要启动检测仪,按下 A。 • 要关闭检测仪,按住 A,直到完成倒计数。 • 要使显示值增加,或向上滚动,按下 G。 • 要进入用户选项菜单,同时按住 G 与 H,直到完成倒计数。
气体检测仪-BW 气体探测器-GasAlertMicroClip-说明书
![气体检测仪-BW 气体探测器-GasAlertMicroClip-说明书](https://img.taocdn.com/s3/m/e08b740b842458fb770bf78a6529647d272834f4.png)
H2S, CO, O2, LELMulti-gas made simpleThe easy to wear, slim and compact GasAlertMicroClip providesaffordable protection from atmospheric gas hazards and extendedbattery life, especially in cold weather. The GasAlertMicroClip featuresvisual compliance at a glance with the flashing, green IntelliFlash™. Easyone-button operation reduces training time and lets workers focus onthe job at hand. For simple, cost-effective management of your records,calibration and bump testing, choose BW’s MicroDock II automatic testand calibration system and Fleet Manager II software.Meets ACGIH 1 ppm H2S TWA recommendations.Visit to download the latest Fleet Manager IIupdate.Standard Package Contents• Detector complete with specified sensor(s), stainless steel alligator clipand concussion-proof housing• Rechargeable battery• Wall outlet charging adaptor• Calibration/test cap and hose• Manual• Multi-language CD manualGeneral SpecificationsGasAlertMicroClip XL GasAlertMicroClip X3Size 4.4 x 2.4 x 1.2 in. /11.3 x 6.0 x 3.1 cm 4.4 x 2.4 x 1.2 in. / 11.3 x 6.0 x 3.1 cmWeight 6.7 oz. / 190 g 6.3 oz. / 179 g Temperature-4 to +122°F / -20 to +50°CTypical battery life18 hours (recharges in less than 6 hours)Note: Battery is guaranteed to have 12 hour runtime during warranty periodunder normal operating temperature of 4°F / -20°C to 122°F / 50°C. Ingress Protection IP68Certifications andapprovals n Class I, Div. 1, Gr. A, B, C, DATEX:X g II 1 GEx ia IIC T4 GaIECEx:Ex ia IIC T4 GaX: European ConformityWarranty Full two-year (GasAlertMicroClip XL) orthree-year (GasAlertMicroClip X3) warranty including all sensorsOrder NumberGasAlertMicroClip 4-Gas Detector GasAlertMicroClip XL GasAlertMicroClip X3GasAlertMicroClip 3-Gas Detector GasAlertMicroClip XL GasAlertMicroClip X3GasAlertMicroClip 2-Gas Detector GasAlertMicroClip XL GasAlertMicroClip X3GasAlertMicroClip 1-Gas Detector GasAlertMicroClip XL GasAlertMicroClip X3Note: To order a unit with black housing, change order number component "-Y-" to "-B-".GasAlertMicroClip Region CodesGas LegendMicroDock IIAutomatic test and calibrationstation (see MicroDock II sectionfor additional information)Confined Space KitOrder NumberCarrying & Protective Accessories Order NumberSampling & Testing EquipmentOrder NumberNote: For complete list of Sampling & Testing Equipment, please refer to the full Price List or contact Honeywell Analytics.Power Options and Spares Order Number *For regions outside North America replace “-NA” with: “-EU” for Europe, “-UK” for United Kingdom and “-AU” for Australia/China.Deluxe Confined Space KitMC-CK-DLOrder detector and calibration gas separately.Test CapMC-TC-1Auxiliary Filter KitMC-AF-K1Easily attaches in the fieldto protect the internal filterManual Aspirator Pump KitMC-AS01For remote sampling; complete with probe,hose, aspirator pump and adaptor capBlack Leather PVC CaseMC2-LC-1Datalogging AccessoriesOrder NumberMicroDock IIOrder NumberReplacement Sensor ScreensOrder NumberReplacement SensorsOrder NumberFor a full list of calibration and testing equipment, please refer to the full Price List or contact Honeywell Analytics.IR Connectivity KitGA-USB1-IRUse for data download andinstrument set-up optionsVehicle Power Adaptor 12-24 V dcGA-VPA-1Direct-Wire Power Adaptor 12-24 V dcGA-PA-3Multi-Unit Power AdaptorGA-PA-1-MC5-NA*Simultaneously charges five detectorsMulti-Unit Cradle ChargerMC2-C01-MC5Simultaneously charges five detectorsNote: Please refer to the instrument’s documentation (shipped with the product or available at ) for complete instructions on common service procedures. Improper servicing or maintenance may affect warranty eligibility. Honeywell assumes no liability for damages resulting from improper servicing or maintenance.LegendService PartsOrder Number Note: Please refer to the instrument’s documentation (shipped with the product or available at ) for complete instructions on common service procedures. Improper servicing or maintenance may affect warranty eligibility. Honeywell assumes no liability for damages resulting from improper servicing or maintenance.How to Replace a Sensor1. With detector OFF , use No. 1 Phillips screwdriver to remove 6screws from back enclosure (E)2. Lift back enclosure (E) straight up3. Use No. 1 Phillips screwdriver to remove 2 screws from backof PCB (D)4. Lift PCB (D) together with battery and sensors (C, G, H, I)straight up5. Remove sensors (C, G, or H) by sliding out or sensor (I) bypulling straight up from PCB (D)6. Insert new sensor (C, G, H, I) into PCB (D)7. Replace PCB (D) and 2 screws and hand-tighten until firm 8. Replace back enclosure (E)9. Replace 6 screws in back enclosure (E) andhand-tighten until firmHow to Replace the Sensor Screen1. With detector OFF , use No. 1 Phillips screwdriver to remove 6screws from back enclosure (E)2. Lift back enclosure (E) straight up3. Use No. 1 Phillips screwdriver to remove 2 screws from backof PCB (D)4. Lift PCB (D) together with battery and sensors (C, G, H, I)straight up5. Remove sensor screen (J) from front enclosure (B)6. Insert new sensor screen (J) into front enclosure (B)7. Replace PCB (D) and 2 screws and hand-tighten until firm 8. Replace back enclosure (E)9. Replace 6 screws in back enclosure (E) andhand-tighten until firm。
BW DEFENDER多气体检测仪 说明书
![BW DEFENDER多气体检测仪 说明书](https://img.taocdn.com/s3/m/f83b99c403d276a20029bd64783e0912a2167c1c.png)
BW Technologies introduces the BW DEFENDER Multi-Gas Detector for monitoring four or two hazardous gases simultaneously and continuously:combustibles,oxygen (deficiency/enrichment),carbon monoxide and hydrogen sulfide.The instrument isdesigned for field friendly operation with large,bright gas/alarm indicators and one button operation.The BW DEFENDER provides effective,reliable protection usingforefront microcontroller and sensor technology .Easier:Permanently attached,dual mode MotorizedSampling Pump monitors in either Active Sampling Modeor Ambient Diffusion Mode.Change modes at the flick ofa switch.Smarter:Advanced Microprocessor operation ensures reliability with morefeatures and simplified user operation.Larger:Individual LCD Readouts for eachGas.Each Gas is identified with the unit ofmeasure (ppm,% 02by volume and % LEL).Records and Displays:TWA (Time Weighted Average) toxic gas exposures.Peak Exposures Encountered for each gas.Displays readings on demandLouder and Brighter:High Output Audible/Visual Alarms.Two “Sunbright"Flashing Alarm LEDs90 dB variable pulsed Audible Alarm.CONVENIENCE and SAFETY:The VERSAPAK NiCad battery is easyto replace and provides up to 16 hoursof operation.Power:BLACK & DECKER VERSAPAKrechargeable "Power Tool" batteryavailable at local retailers worldwide.Simpler:Single push-buttonoperation.Tougher:Rugged,RFIProtected,ErgonomicallyDesigned Enclosure.Smaller:Weighsonly 14.85 ouncesincluding the battery and sampling pump.The compact,lightweight BW DEFENDER fits in the palm of your hand.Simply smarter and easier to use with functions performed automatically.The larger alphanumeric LCD screens keep you advised of any gas hazard present.BW DEFENDER automatically executes a Self Test each time it is turned ON.- Auto Zero and Auto Calibration -Auto zero the sensors,at any time,without calibration gas. Calibrate one or all four sensors automatically.BW DEFENDER will advise when to apply gas and check the test gas to see which sensors are to be calibrated.The plug-in sensors housed ina separate sensor compartmentare unobtrusively and easilychanged at any time,even in the field.- Audible Visual Alarms -Audible and multiple visual alarmsactivate ensuring maximum protection.Low and High alarms are factory set tocurrent OSHA standards and can be resetby the user at any time.In Low Alarm,the audible sounds in a slow repeatingpattern and the visual alarm LEDs willflash in sync.High Alarm conditionsfeature an urgent faster audible andvisual pattern.As well,the LCD readoutflashes to advise you which gas hazardis present and the Low and/or High alarm ICON appears and flashes indicating the Alarm level exceeded.Also,the LCD backlight illuminates while in alarm condition.- Integral Sampling Pump -Conveniently change from active motorized sampling mode to diffusion mode at the flick of a switch.Permanently attached, the rugged pump is one less item to carry,charge or maintainin the field.The revolutionary,high efficiency rotary vane design provides the benefits of a small turbine - greater reliability with less friction - it is not pressure sensitive.Should a hose/probe become clogged or plugged,the audible/visual Low Flow Alarm will trigger.If the pump is continuously operated by theBW DEFENDER battery,expect 8-9 hours operation.Carrying Cases:The top grain leather case has a belt loopand a clear front cover.Access the controlswithout removing the detector.A shockresistant carrying boot is also available.Calibration Gases and Kits:BW DEFENDER quality quad (four in one)Calibration and Alarm Test gases ensureaccuracy.Kits include the gas cylinder andregulator in a convenient carrying case.STATUS at a Glance:BW DEFENDER ICONS and the intelligentalphanumeric LCD readouts provide informationand guidance clearly and quickly.- Additional Features and Functions -Two (2) levels of Alarm for each gas sensed.Current Alarm Setpoints are displayed each time theinstrument is turned ON.Low Battery Warning provides a 30 minute alert.LCD Backlight activated in poor light at the touch of a button.LCD Backlight illuminates in any gas alarm condition.BW DEFENDER cannot be accidentally shut OFF.Missing sensor alarm advises which sensor is missing.LEL sensor Over-Range alarm advise protection.Confidence Beep is field selectable.Gas Alarms take priority over all other alarms.2 Year Warranty on all sensors.Confined Space Kit:The value added kit includes aBW DEFENDER complete withmotorized sampling pump,10' samplehose,2 VERSAPAK batteries,110 VACcharger,wrist strap,calibration gascylinder,regulator,and carrying case.Remote Sampling Accessories:The tygon Sampling Hoses and SamplingProbes are equipped with quick connectsfor easy field use.Sampling Pump Modelscome complete with a 10 foot hose. Batteries and Fast Chargers:The BW DEFENDER includes2 VERSAPAK "Power Tool"NiCad Batteries and a 2-portBLACK & DECKER 3 hourcharger.A Vehicle Charger isalso available.Battery Level:The batterycondition is constantly displayed.Alarm Advise:Flashing iconsadvise the Gas Alarm Levelencountered - Low,High,STEL,TWA or Multiple gas alarm.Motorized Pump:The FAN iconappears and spins when the pumpis ON and flashes in Low Flow Alarm.Automatic Zero/Calibration: Advisesas each automatic function takes placeand when to apply gas.Password Security: The KEY icon is litif calibration and alarm setpoint functionsare password protected.External Alarms:A.Vibrating AlarmB.Audible/Visual Alarm A.B."Innovators in Gas Detection"SPECIFICATIONSBW DEFENDER MULTI-GAS DETECTOR Size:4 x 4.8 x 1.4 in.(10.3 x 12.4 x 3.6 cm)4 x 6 x 1.4 in.(10.3 x 15.4 x 3.6 cm) with Sampling Pump Weight:13.27 ounces (375 grams) including battery 14.85 ounces (424 grams) including battery and Sampling Pump Enclosure:Rugged,high impact resistant,composite material,RFI/EMI shielded Sensors:Combustible Gases:Plug-in Catalytic Toxic & Oxygen Gases:Plug-in Electrochemical Measuring Range:Combustible Gases:0 to 100% LELOxygen:0 to 25% by volumeCarbon Monoxide:0 to 500 ppmHydrogen Sulfide:0 to 100 ppmPower Source:Rechargeable BLACK & DECKER VERSAPAK NiCad batteryBattery Life:Diffusion Model up to 16 hours;Continuous Pump operation 8 - 9 hoursDisplay:Four (4) large gas specific alphanumeric LCD readoutsTemperature Range:-20 to +50ºC (-4 to +122ºF) Lower temp.range versions availableHumidity: 5 to 95% RH non-condensingWarranty:Full 2 year warranty including all sensors - BW DEFENDER is delivered complete - ready for use with -The BLACK & DECKER 2-port 110 VAC Charger, two VERSAPAK Batteries, Earphone, Wrist Strapand Calibration Cup Adaptor with Diffusion Models - Not required with Pump Models.ORDERING INFORMATIONValue Added Confined Space Kit:D4-CS-KIT Includes complete instrument in a rugged hard sided Carrying Case;4-Gas BW DEFENDER with Motorized Sampling Pump,10 foot SamplingHose,BLACK & DECKER 2-port 110 VAC Charger,two VERSAPAKBatteries,Earphone,Wrist Strap and Quad 34 litre Calibration GasCylinder and Calibration Hose.Complete Instrument:D4-2002-SP4-Gas BW DEFENDER (LEL,O 2,CO,H 2S) with Motorized Sampling Pump D2-2002-SP2-Gas BW DEFENDER (LEL,O 2) with Motorized Sampling Pump D4-20024-Gas BW DEFENDER D2-20022-Gas BW DEFENDER Note 1:Add Suffix "-AU" for Australian Models.Note 2:Add Suffix "-A" to omit 110 VAC Charger and Batteries from order.Accessories:D4-VP160 4-port BLACK & DECKER 110 VAC ChargerD4-VP140 2-port BLACK & DECKER 12 volt Vehicle ChargerD4-VIB(##) Vibrator Alarm specify 1.5 or 3 ft.cableD4-HL-R3 Audible/Visual External Alarm 3 ft.cable (extensions available)D4-2-LC Leather Carrying Case c/w Belt LoopD4-2-CC Shock Resistant Carrying Case c/w Belt LoopD4-SPO1 Motorized Sampling Pump field Upgrade Kit c/w 10 ft.HoseD4-AS01 Hand Aspirator Pump c/w 10 ft.Sampling HoseD4-PROB1 1 foot Polycarbonate Sampling ProbeD4-PROB3 3 foot Polycarbonate Sampling ProbeD4-2-EC Hard Sided Equipment Carrying CaseD4-E2358 EarphoneM1858 Dilution TubeD4-UPGRADE1 2 to 4 Gas Upgrade Kit (includes TWIN TOX Sensor)Calibration Equipment:CG-Q58 Quad (four in one) 58 litre Calibration Gas Cylinder CG-Q34 Quad (four in one) 34 litre Calibration Gas Cylinder CG-BUMP1 Alarm Test Gas 7 litre Aerosol Cylinder CK-Q58 Calibration Kit c/w 58 litre gas Cylinder,Hose,Regulator and Carrying Case CK-Q34 Calibration Kit c/w 34 litre gas Cylinder,Hose,Regulator and Carrying Case REG-0.5 Calibration 0.5 LPM Regulator Spare Parts:D4-RW90Combustible Sensor SR-X10Oxygen Sensor (2 YEAR)D4-RHM04TWIN TOX Two sensors (CO,H 2S) in one detectorE2339 Sensor Blank for TWIN TOX Sensor NOTE:This Data Sheet contains a general description of uses and performancesof the BW Defender.This product should be used by trained professionalpersonnel who have read and understood the manual,instructions,labels,and other literature accompanying the product.Only they contain thecomplete and detailed information about the product.Classified to U.S.and Canadian Standards by CSA Class I,Div.1,Groups A,B,C,DClass I,Zone 0,Gr.IICCenelec Certified by LCIEEExia d IIC Certified for use in Australia Ex ia s IIC for Zone 0Approved by the American Bureau of Shipping。
多种气体检测仪培训手册PPT课件
![多种气体检测仪培训手册PPT课件](https://img.taocdn.com/s3/m/eeaf43a559f5f61fb7360b4c2e3f5727a5e924f9.png)
报警级别可以通过CC-Vision软件设置和更改声、光和振动报警周期重复出现, 屏幕交替显示 “A2” 和气体浓度闪烁 图标 报警无法被确认
Look at video
重设仪器后会取消TWA和STEL值.遵从所述安全操作流程.
TWA 报警
报警级别可以通过CC-Vision软件设置和更改声、光和振动报警周期重复出现屏幕交替显示 “A2” 和气体浓度闪烁 图标报警无法被确认
Look at video
最大值菜单最大值菜单Look at video
显示氧气传感器的最大值. 数值从仪器上次重设起开始记录。 再按 “OK”键.
按住 “OK”-键3秒钟
或者按一下“+”键仪器返回测量模式最大值功能显示重设仪器读数后氧气最低浓度值和其它气体最高浓度值。用户可以使用快捷菜单查看最大值也可利用CC viபைடு நூலகம்ion软件设置最大值数值。
注意!每次测量前,需要用空气冲洗德尔格取样管活着取样探枪.测量经验: 使用新取样管时,每米平均冲洗时间为3秒钟。测量时应加上传感器响应时间。
执行测量: 将德尔格取样管或者德尔格探枪与外置泵进气口连接 执行测量完成操作: 按下松开键 LED灯闪烁绿/红灯,短暂发出鸣音 外置泵自动关闭
X-AM 1/2/5000/5600外置泵操作
注释
TWA
当 TWA分析功能激活后:按住 “OK”-键3秒钟按下 “OK ”-键一次屏幕上显示 图标 显示最大工作浓度再次按下“OK”-键显示STEL 值.或者再按一下“+”键仪器返回测量状态
菜单功能
Look at video
菜单功能
当STEL分析功能激活后:按住“OK”键三秒钟按下 “OK ”键两次屏幕上显示 图标 显示STEL 值按下 “OK ”-键或者 “+”键一次仪器返回测量
GasAlertMicroClip多种气体检测仪 说明书
![GasAlertMicroClip多种气体检测仪 说明书](https://img.taocdn.com/s3/m/223d8ea768dc5022aaea998fcc22bcd126ff428f.png)
s22多种气体检测仪保护自己S 坚固耐用,紧密结构(4.2 x 2.4 x 1.4 英寸/10.7 x 6.0 x 3.6 厘米), 并且重量非常轻(5.6 盎司/160 克) S 单按钮操作,使用简单S 标准的数据记录器(16 小时)和事件记录器(10 个事件)S 不锈钢鳄鱼夹,坚固耐用S 连体的防震外罩能够适应最恶劣的环境S 不间断的 LCD 同时显示 H 2S、CO、O 2 以及可燃气体的浓度 (0-100% LEL 或 0-5.0% 甲烷)S 采用锂聚合电池供电(正常工作时间达 12 小时; 不到 3 小时即可完成充电)S 可发出 100 分贝的警报鸣声和明亮的广角闪光警报 (典型)S 配有内置振动警报,适用于高噪声区S 背景光:报警(自动)以及根据指令重新启动S 4 个警报级别:针对所有气体的瞬时低限和高限警报;针对 H 2S、CO 的 TWA(时间加权平均值)和 STEL(短期曝露 极限)警报;以及 OL(超限警报)S 简易的自动校准程序S 与 BW 的 MicroDock II 自动测试和 校准系统完全兼容S 记录 TWA、STEL 和最大气体浓度并根据指令 显示读数S 用户可选择的选项包括:提示音、锁定 警报、校准到期日、冲 击到期日、“SAFE”显示 功能、多语言、浓度值变化范围、 可燃气体 传感器测量选择(0-100%LEL 或 0-5.0% v/v 甲烷)和 静音模式S 全功能自检:传感器、电池、电路和 声音/闪光/震动警报S 配有传感器、锂聚合电池、不锈钢腰带鳄鱼夹、校准软管/盖和说明书n X g以及其它ATEX 定购信息GasAlertMicroClip 配有传感器(根据指定)、不锈钢鳄鱼夹、电池充电器、校准盖/软管、说明书(本地语言)和交互式培训光盘。
H 2S, CO, O 2, LEL MC-XWHM-Y-NA-00H 2S, O 2, LEL MC-XWH0-Y-NA-00CO, O 2, LEL MC-XW0M-Y-NA-00O 2, LEL MC-XW00-Y-NA-00H 2S, CO MC-00HM-Y-NA-00增值的受限空间工具包工具包中有检测仪、标准附件及一个 IR 连接套件、带泡沫衬里的硬质手提箱、采样设备和校准气瓶(带调节器)。
BW GasAlertMicro 5 Multi-Gas Detector Series 说明书
![BW GasAlertMicro 5 Multi-Gas Detector Series 说明书](https://img.taocdn.com/s3/m/0d9d4f989fc3d5bbfd0a79563c1ec5da50e2d6a6.png)
Wear Yellow. Work Safedetectores multi-gasSerie• Mide hasta cinco peligros atmosféricos simultáneamente• Totalmente adaptable para cualquier aplicación • Cambia rápidamente del modo de difusión a la bomba integrada opcional en el campoO 3Sobre la base del tiempo de operación de un instrumento de 5 gases en modo de difusión a +68°F/+20°C, otras configuraciones del instrumento o condiciones ambientales pueden aumentar/reducir la vida útil de la batería de su instrumento.Cambia rápidamente de la opción de difusión a la debomba integralFiltro integrado reemplazable • la ventana permite que el usuario inspeccione visualmente el filtro• proporciona resistencia superior al polvo y al agua de gases tóxicos, PID o CO 2Pantalla grande y de fácil lecturaBotones elevados, fáciles de usar aún usando guantes Alarma sonora de 95 dB (valor típico)Cuatro barras de alarma brillantes y de gran ánguloEl registro de datosopcional almacena varios meses de datos continuosVarias opciones de carga disponiblesBroche tipo caimán de acero inoxidableLas opciones con pilas AA alcalinas o con paquete de baterías recargables, que se pueden cambiar funcionamiento, permiten la instalación de baterías en el campoAlarma vibratoria interna para áreas con alto nivel de ruidoCarcasa integral a prueba de golpesAplicaciones industrialesLas configuraciones para modo de difusión y con bomba son compatibles con el sistema automático de calibración y prueba de respuesta MicroDock IISensoresGasAlertMicro 5 viene en tres modelos: tóxico/electroquímico, PID (para compuestos orgánicos volátiles) o IR (para CO 2). Para obtener más información sobre las configuraciones disponibles de los sensores, póngase en contacto con BW T echnologies by Honeywell.Sensores electroquímicos y de perla catalítica disponibles para: H 2S CO O 2SO 2 Cl 2 ClO 2NH 3 PH 3 HCN NO 2 O 3 Gases combustibles (LEL)Sensor de fotoionización disponible para la detección de compuestos orgánicos volátiles.Sensores infrarrojos (IR) de serie de oro disponibles para la detección de dióxido de carbono (CO 2).Nota: Debido a la configuración de los circuitos y sensores los modelos GasAlertMicro 5 no son intercambiables (es decir, un sensor PID no se puede usar en una unidadconfigurada para IR).Opciones y accesoriosCargador de batería Sonda de muestreo。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
加拿大BW GAMIC-5
多功能气体检测仪
说
明
书
青岛聚创环保设备有限公司
一、产品特点:
1、GasAlertMicro5便携式气体探测仪同时监察和显示最多五种危险的气体状况,包括氧气、可燃气体和各种有毒气体。
2、小巧轻便的GasAlertMicr05将多种气体探测加入BW Technologies防水探测仪行列。
3、在低、高、TWA、STEL四个级别报警状况出现时发出声光振动警报。
另外还能选择电动泵。
4、除了BW便携式气体探测仪的标准性能,如提示音、全功能自检、自动校准和密码保护,GasAIertMicr05用户还有更多选择包括:秘密模式、背光选择、可选择PPM精度、STEL 和TWA测量标准选择、可燃气体/PID修正因数选择、用户自设校准气体浓度和多种语言支援。
二、产品规格:
1、自动归零:是
2、校正:自动
3、背照灯:标准模式:弱光(自动);报警状况(自动);可根据需求重新激活
4、报警模式:报警状况(自动),根据需要再次激活
5、秘密模式:背照灯不亮,声光报警停用
6、功能测试:传感器的完整性、电路及电池;声音/视觉报警
7、传感器:插接式电化学式电池(毒气及氧气);催化式(LEL)
8、用户选项:提示音、密码保护、锁定警报、校正过期锁机设定、“SAFE”显示功能、秘密模式、开机时氧气自动校准
9、警报指示:视觉、声音/振动报警清楚显示报警状况和级别
10、视觉报警:两段明亮闪烁广角报警灯、LCD屏幕显示出现的气体和报警级别
11、声音报警:典型1英尺/0.3米外为95分贝的高输出可变脉冲警报声
12、振动警报:在气体报警状态下发出振动警告,或显示其他报警状况
13、报警级别:所有气体的即时低限和高限报警;有毒气体的TWA(时间加权平均值)和ST EL(短时间内暴露限度)报警
14、L C D:持续字母数字型气体读数和状态显示说明:
15、气体类型:H2S, CO, O2, SO2, PH3, NH3, NO2, HCN, Cl2, ClO2, O3, and combusti bles
三、产品配置:
1、功能测试:启动时执行全功能自测试
2、电池:不间断
3、一般规格:抗冲击复合材料,双层注射成型防震护套
4、工作温度:华氏—4至122度/摄氏—20至50度
5、湿度:5%至95%相对湿度(无凝结)
6、保护级别:高性能防水防尘外壳
7、电池类型:3节AA碱性电池可工作14小时(配备电动泵10小时*) 可充电“热更换式”电池组可工作18小时(配备电动泵13小时*)
8、尺寸:5.7X2.9X1.5英寸,4.5x7.4x3.8厘米
9、重量:13.1盎司/370克
10、保修期:两年完整质保,包括全部传感器
11、数据记录:用户下载数据记录器
12、存储:32MB的MMC闪存卡可保存2个月的持续数据(还可提供64MB/128M的内存卡);。