MIK-LCS1拉压力传感器 - 污水流量计压缩空气流量计磁性
First Sensor MLH系列金属压力传感器产品说明书

MLH SeriesAll Metal Pressure SensorsDESCRIPTIONMLH Series pressure sensors combine Application Specific Integrated Circuit (ASIC) technology with a media isolated, metal diaphragm design. This digitally compensated sensor offers value and performance, making it the ideal pressure sensing solution for demanding applications. Fully temperature compensated, calibrated and amplified, the MLH is available in 50 psi to 8,000 psi pressure ranges.MLH sensors deliver ±0.25% full scale accuracy Best Fit Straight Line (BFSL) and as low as 2% total error over a temperature range of -40 °C to 125 °C [-40 °F to 257 °F]. Industry standard connectors and process ports are offered for enhanced reliability and user flexibility.The MLH has seven standard output options:A. 0.5 Vdc to 4.5 Vdc ratiometric output from 5 Vdc excitationB. 4 mA to 20 mA current from 9.5 Vdc to 30 Vdc excitationC. 1.0 Vdc to 6.0 Vdc regulated output from 8 Vdc to30 Vdc excitationD. 0.25 Vdc to 10.25 Vdc regulated output from 14 Vdc to30 Vdc excitationE. 0.5 Vdc to 4.5 Vdc regulated output from 7 Vdc to30 Vdc excitationF. 0 mV to 50 mV from 5 Vdc excitationG. 1 Vdc to 5 Vdc output from 8 Vdc to 30 Vdc excitationFEATURES• All metal wetted parts for use in wide variety of fluidapplications• No internal elastomeric seals mean no o-ring compatibilityissues• Amplified outputs eliminate cost of external amplifiers • Input reverse voltage and output short circuit protectionsguard against mis-wiring• Less than 2 ms response time provides accurate, highspeed measurement• Rated IP65 or better for protection from harsh environmentsPOTENTIAL APPLICATIONS • Compressors• Refrigeration and HVAC/R • General industrial • General hydraulics• Multiple transportation applications including braking andalternate fuels • MedicalMLH Series2 /sensingTable 1. Pressure Range Specifications 1(At 25 °C [77 °F] and at rated excitation unless otherwise specified.)psiPressure 50 100 150 200 250 300 500 1000 2000 3000 5000 8000 Proof pressure 150 300 450 600 750 900 1500 2000 4000 6000 7500 12000 Burst pressure 500 1000 1500 2000 2500 3000 5000 10000 20000 30000 30000 30000barPressure 6 10 16 25 40 60 100 160 250 350 500 550 Proof pressure 18 30 48 75 80 120 200 320 500 700 750 825 Burst pressure60 100 160 250 400 600 1000 1600 2068 2068 2068 2068Note:1. Comparable metric units follow same proof and burst specifications.Table 2. Physical and Environmental SpecificationsParameter Characteristic Material in contact with media stainless steel 300 series and Haynes 214 alloy, Hastelloy C22 sensor available (contact factory) Housing material black plastic – Amodel AS-4133 HS – PPA Weight 57.0 g [2.0 oz] (typical for Packard MetriPak and 1/8 NPT port) Shock 100 g peak [11 ms] Vibration MIL-STD-810C, Figure 514.2-5, Curve AK, Table 514.2-V, Random Vibration Test [overall g rms =20.7 min.]Compensated, operating and storage temperature range-40 °C to 125 °C [-40 °F to 257 °F]Table 3. Electrical Specifications (At 25 °C [77 °F] and at rated excitation unless otherwise specified.) Parameter Ratiometric(A)1 Current (B) Regulated(C) Regulated(D) Regulated(E) mV (F) Regulated(G) Zero output 0.5 Vdc4.0 mA1.0 Vdc0.25 Vdc0.5 Vdc0 ±2.5 mV1.0 VdcFull scale span (FSS) 4.0 Vdc (0.5 to 4.5 Vdc) 16 mA (4 to 20 mA) 5.0 Vdc (1.0 to 6.0 Vdc) 10.0 Vdc (0.25 to 10.25 Vdc) 4.0 Vdc (0.5 to4.5 Vdc) 50 mV (0 to 50 mV) 4.0 Vdc (1.0 to 5.0 Vdc)Excitation 5 Vdc (6.0 Vdc max.) 9.5 Vdc to 30.0 Vdc 8.0 Vdc to 30.0 Vdc 14.0 Vdc to 30.0 Vdc 7.0 Vdc to 30.0 Vdc5.0 Vdc (6.0 Vdc max.)8.0 Vdc to 30.0 VdcSupply current 4.0 mA typical (8 mA max.)N/A 5.0 mA typical (17 mA max.)5.0 mA typical (17 mA max.)5.0 mA typical (17 mA max.) 8.0 mA typical (17 mA max.) 5.0 mA typical (17 mA max.)Source (nominal) 1.0 mA N/A 1.0 mA 1.0 mA 1.0 mA N/A 1.0 mA Sink(nominal) 1.0 mA at zero outputN/A 1.0 mA at zero output1.0 mA at zero output1.0 mA at zero outputN/A 1.0 mA at zero outputSupplyrejection ratio 90 db 90 db 90 db 90 db 90 db N/A90 dbOutput impedance25 Ω max.N/A25 Ω max.25 Ω max.25 Ω max.2000 Ω 25 Ω max.Note:1. Maintains ratiometricity at 5 ±0.25 Vdc excitation. Product can tolerate 6 Vdc excitation without damage.All Metal Pressure SensorsHoneywell Sensing and Control 3Table 4. Performance Specifications (At 25 °C [77 °F] and at rated excitation unless otherwise specified.)Parameter Characteristic Response time <2 msAccuracy 1:>100 psi<100 psi±0.25% FSS ±0.50% FSS Total error band 2:Gage:<300 psig>300 psigSeal gage:>300 psisSeal gage without L, M, P termination:100 psis to 299 psis (-40 °C to 85 °C [-40 °F to 185 °F])100 psis to 299 psis (>85 °C to 125 °C [>185 °F to 257 °F])>300 psis (-40 °C to 125 °C [-40 °F to 257 °F])Seal gage with L, M, P termination:100 psis to 299 psis (-40 °C to 65 °C [-40 °F to 149 °F])100 psis to 299 psis (>65 °C to 125 °C [>149 °F to 257 °F])>300 psis (-40 °C to 65 °C [-40 °F to 149 °F])>300 psis (>65 °C to 125 °C [>149 °F to 257 °F])±3% FSS ±2% FSS ±2% FSS ±3% FSS ±10% FSS ±2% FSS ±10% FSS ±15% FSS ±5% FSS ±15% FSS Notes:1. Includes pressure non-linearity (BFSL), pressure hysteresis and non-repeatability. Thermal errors are not included.2. Includes zero error, span error, thermal effect on zero, thermal effect on span, thermal hysteresis, pressure-non-linearity,pressure hysteresis and non-repeatability.1Sensing and Control Honeywell1985 Douglas Drive North Golden Valley, MN 55422 /sensing 008118-5-EN IL50 GLO Printed in USAJanuary 2009Copyright © 2009. Honeywell International Inc. All rights reserved.Figure 2. Mounting Dimensions (For reference only. mm/(in).)Pin and Wire Codes (Option B – Packard)Pin Voltage Current a + Excitation + Excitation b Output - Excitation c Common No ConnectionA variety of pressure ports and electricaltermination connection options are available. Refer to the “How to Order” on previous page for possible combinations. Contact your Honeywell representative for details.WARNINGMISUSE OF DOCUMENTATION• The information presented in this product sheet is forreference only. Do not use this document as a product installation guide.• Complete installation, operation, and maintenanceinformation is provided in the instructions supplied with each product.Failure to comply with these instructions could result in death or serious injury.WARRANTY/REMEDYHoneywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. Theforegoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.While we provide application assistance personally,through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.Specifications may change without notice. Theinformation we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.WARNINGPERSONAL INJURYDO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.Failure to comply with these instructions could result in death or serious injury.SALES AND SERVICEHoneywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or:E-mail:*********************Internet: /sensingPhone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 F ax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 F ax。
意大利伊莱科流量指示器与流量指示仪说明书

FLOW METERS AND INDICATORS MUST BE MOUNTED AT LEAST 50mm FAR FROM IRON PARTS OR WALLS AND OTHER POSSIBLE INTERACTING MAGNETIC FIELD. WARNING: any combination of the switching voltage and current must not exceed the given rated po簧 M6 粘度至14/4 cSt. • 弹簧 M7 粘度至39/8 cSt. • 弹簧 M8 粘度至70/4 cSt. • 弹簧 M9 粘度至119/2 cSt. • 弹簧 M10 粘度至205/6 cSt.
流量指示器以及流量指示器在安装时必须离内墙或者钢铁物体至少50 毫米的地方,要远离可能引起干扰的磁场。
CONVERSION TABLE OF WATER/AIR FLOW RATE RELATIVE TO
IF...V-VE-E FLOW METERS AND INDICATORS
Model Water LPM Air Nm3/h
IF1... 0.1 - 01
0.2 - 2
IF2... 0.2 - 03
0.35 - 5
IF3...
1 - 06
2 - 10
IF4...
2 - 16
3.5 - 29
IF5...
5 - 60
10 - 110
SPRINGS TO BE USED WITH FLUIDS MORE VISCOUS THAN WATER • Spring M6 Viscosity up to 14.4 cSt. • Spring M7 Viscosity up to 39.8 cSt. • Spring M8 Viscosity up to 70.4 cSt. • Spring M9 Viscosity up to 119.2 cSt. • Spring M10 Viscosity up to 205.6 cSt.
电磁流量计(上海光华)

工作压力 工作电流 防护等级
最大潜水深度 5m ≤0.5A或≤0.25A IP68(防潜水)
配套 转换器型号 输出信号
显示 通讯接口 适用电源
应用
LDZ-4B、4B(S)型 LDZ-5型 、LDZ-6型 0~10mA DC或4~20mA DC
* * 频率 (脉冲) 上限1-5000Hz (上限5000CP/S)
ISO 9001
注册证号: CCQE0800A0130
沪制00000214
LDG-/K 传感器
LDZ-4B、4B(S)型 转 换 器
中国 核工 业集团公司 上海光华 仪表 厂
目 录
1.概述 ..................................................................................................................................................................1 2.工作原理...........................................................................................................................................................1 3.性能简介...........................................................................................................................................................2 4.外形和安装尺寸................................................................................................................................................5 5.电磁流量计口径的选择.....................................................................................................................................8 6.电极材料的选择..............................................................................................................................................10 7.衬里材料的选择..............................................................................................................................................11 8.防护等级的选择..............................................................................................................................................11 9.接地环的选择..................................................................................................................................................11 10.传感器在管道上的安装..................................................................................................................................11 11. 选型编码说明................................................................................................................................................16 12.电磁流量转换器............................................................................................................................................18 13.防爆合格证...................................................................................................................................................22
气体罗茨流量计

◆无接触密封、自清洁功能和对轴承的充分润滑。
◆坚固而不变的计量室,确保永久的、非调整的高精度。
◆不承压、可更换的模块式设计,简化了仪表互换性。
◆采用新型旋转检测技术检测流量计轮子转速,能彻底解决脉动流引 起的误计量和脉冲信号丢失问题,保证补偿仪与机械计数器的数值 同步。
特殊要求 1.0级 Qmin≤Q<0.05Qmax:±2.0% 0.05Qmax≤Q≤Qmax:±1.0%
200:1
260:1
100:1
160:1
160:1
Qmax时压 SSP输出 力损失kPa m3/脉冲
0.10
0.1
0.07
0.1
0.09
0.1
0.14
0.1
0.25
0.1
0.20
1
0.22
1
0.18
量程 比
最大允许误差
40:1 50:1 80:1
基表: 1.0级 Qmin≤Q<.05Qmax:±2.0% 0.05Qmax≤Q≤Qmax:±1.0%
130:1 200:1 250:1 160:1 160:1
修正型: 1.5级 Qmin≤Q<0.05Qmax:±2.5% 0.05Qmax≤Q≤Qmax:±1.5%
气体罗茨流量计
N转通过机械或电子传递装置将动作传递到计数显示装置,使 其数字累加,以显示通过流量计的气体体积,因此,显示值VI 和 N的关系可以表示为
VI =aN
a——与传动比和计数单位量值有关的流量计常数。
•理想误差特性:
上式中表示,罗茨流量计的误差只 与计量室空间的容积v和传动比常数a有 关。
▲安装与维护方式
DMF-LK 系列科氏力质量流量计 使用说明书

使用说明书DMF-LK系列科氏力质量流量计龙口中隆计控设备有限公司目录第一章概述 (4)1.1工作原理: (5)1.2流量计的技术参数 (7)1.3流量计结构与外形尺寸 (10)1.3.1 变送器外形及机柜开孔尺寸图: (10)1.3.2传感器的外形尺寸图 (11)1.3.3技术性能指标 (14)1.3.4质量流量计的型号与选型 (16)第二章质量流量计的安装与调试 (16)2.1质量流量传感器的安装 (16)2.2传感器与变送器的接线 (19)2.3变送器的接线 (20)2.4仪表的通电和检查 (21)2.5 常见故障的维护 (21)第三章变送器的设置 (22)3.1功能设置 (22)3.1.1用户菜单密码 (22)3.1.2系统菜单密码 (22)3.1.3测量单位的选择 (22)3.1.4小数点位数的选择 (22)3.1.5电流输出的设置 (23)3.1.6频率输出的设置23 3.2仪表面板 (23)3.3 操作界面 (24)3.4 零点校准 (29)第四章防爆 (30)4.1防爆系统的原理 (30)4.2 防爆性能 (30)4.3 防爆性能试验 (30)附录:RS485通讯协议 (31)第一章概述DMF-LK系列质量流量计是根据科里奥利(Coriolis Force)原理,实现流体质量流量的直接精密测量,而无需任何压力、温度、粘度、密度等换算或修正。
其结构是由传感器单元和变送器单元两部分组成。
仪表按本质安全防爆型的国家标准设计与制造,防爆标志为Exdib[ib]IIBT5科里奥利质量流量计能够直接测量流体的质量,具有高精度(0.1%~0.2%),应用范围广(可测量各种非牛顿流体、各种浆液、悬浮液、高粘度流体等),安装要求低(对仪表的前后直管段要求不高),运行可靠、稳定,维修率低等特点。
本公司保留对该说明书内容修改的权利。
用户使用时以随机发货的说明书为准。
1.1工作原理:当一个位于以P点为旋转中心做旋转运动的管子内的质点做朝向或远离旋转中心的运动时,将产生一贯性力,原理如图1:图1图中质量为δm的质点以匀速v围绕一个固定点P并以角速度ω旋转的管道内移动时,这个质点将获得两个加速度分量:1.法向加速度αr(向心加速度),其量值值等于ω2r,方向朝向P点;2.切向加速度αt(科里奥利加速度),其量值等于2ωv,方向与αr垂直。
大连迈克流体技术流量计使用说明书

3、 传感器适用于在工作温度下粘度小于 5×10-6m2/s 的介质,对于大于 5×10-6m2/s 的液体,要对传感器进行实液标定后使用。
二、MKLY 涡轮流量传感器
2.5
80~800
2.5
安装形式 精确度 前置放大器电源
螺纹 螺纹 螺纹 螺纹 螺纹 螺纹 法兰 法兰 法兰 法兰 法兰
0.5 1
0.5 1
0.5 1
0.5 1
0.5 1
0.5 1
0.5 1
0.5 1
0.5 1
0.5 1
0.5 1
+12 +12 +12 +12V +12V +12V +12V +12V +12V +12V +12V
(3) (4) (5) (6)
环境温度:-20~+50℃ 供电电源:电压:-12V±10%,电源:≤10m A。 输出电压幅值:高电平≥8V,低电平≤0.8V。 传输距离:传感器至显示仪表的距离可达 1000m。
3.结构安装 (1) 结构:
4
大连迈克流体控制技术有限公司______________________________________________________________
M KLY- 50 ~ 20 0 传 感 器 结 构 及 安 装 尺 寸 示 意 图
(2) 安装
① 传感器的安装方式根据规格不同,采用螺纹或法兰连接,安装尺寸见表 2。
表2
产品型号 公称通径
L
MIK-LWGY讲解

涡轮流量传感器安装使用说明书一、概述涡轮流量传感器(以下简称传感器)基于力矩平衡原理。
传感器具有结构简单、轻巧、精度高、复现性好、反应灵敏,安装维护使用方便等特点,广泛用于石油、化工、冶金、供水、造纸等行业,是流量计量和节能的理想仪表。
选用本产品的防爆型式(ExmIIT6),可在有爆炸危险的环境中使用。
传感器适用于在工作温度下粘度小于5×10-6m2/s的介质,对于粘度大于5×10-6m2/s的液体,要对传感器进行实液标定后使用。
如用户需用特殊形式的传感器,可协商订货,需防爆型传感器时,在订货中加以说明。
(1) 基本参数:见表(一)DN4—DN40口径的传感器为螺纹连接,最大工作压力为6.3Mpa;DN50—DN200口径的传感器为法兰连接, 最大工作压力为2.5Mpa;DN4—DN10口径的传感器带有前后直管段、过滤器。
DN15以上口径的传感器我公司可配套前后直管段。
DN25-DN40口径的传感器也可制作成法兰连接,但需在订货时说明。
(2) 介质温度:-20~+120℃。
(3) 环境温度:-20~+55℃。
(4) 供电电源:电压:12V±10%, 电流:≤10mA。
(5) 输出电压幅值:高电平≥8V,低电平≤0.8V。
(6) 传输距离:传感器至显示仪表的距离可达1000m。
2.3.1 安装传感器的安装方式根据规格不同,采用螺纹或法兰连接,安装方式见图(一)、图(二)、图(三),安装尺寸见表(二)。
1.过滤器2.前直管段3.叶轮4.前置放大器5.壳体6.后直管段整表结构图图(一)—4~10传感器结构及安装尺寸示意图1. 壳体 2.前导向件 3.叶轮 4.后导向件 5.前置放大器图(二)—15~40传感器结构及安装尺寸示意图5.前置放大器 6.叶轮 7.轴承 8.轴传感器可能产生的一般故障及消除方法见表(三),维护周期不应超过半年。
用户遵守说明书的规定进行保管和使用的情况下,从制造厂发货日起一年内,传感器因制造不良以至不能正常工作时,制造厂可免费修理。
米科U-MIK-LDGR-LCN1电磁式冷热量表使用说明书

8.1 故障处理......................................................................................55 第九章 技术参数...........................................................................................57
第四章 电气连接...........................................................................................21
III
4.1 安全提示......................................................................................21 4.2 连接信号电缆............................................................................. 21 4.3 接线端子......................................................................................22 4.4 输出与电源线............................................................................. 24 4.5 转换器安装接地要求................................................................. 25 4.6 数字量输出及计算..................................................................... 26 4.7 模拟量输出及计算..................................................................... 29 第五章 启动...................................................................................................31 5.1 开启电源......................................................................................31 5.2 转换器启动................................................................................. 31 第六章 操作(分体式).............................................................................. 32 6.1 显示和按键形式.......................................................................... 32 6.2 按键功能.......................................................................................33 6.3 参数设置功能及功能键操作..................................................... 33 6.4 功能选择画面............................................................................. 35 6.5 参数设置菜单............................................................................. 38 6.6 仪表详细参数说明..................................................................... 42 第七章 操作(一体式).............................................................................. 53 7.1 显示和按键形式......................................................................... 53 7.2 按键功能......................................................................................54 第八章 维护与检修.......................................................................................55
合肥科迈捷 TGF450 系列 热式气体质量流量计 产品数据手册说明书

产品数据手册 Rev1.0Date:3/03/2015 Data sheets◆ 直接式测量气体质量◆ 宽量程比,可测量低至0.3Nm/s ◆ 响应速快,测量精度高◆ 多参数测量,可测量流量、温度、压力,节省成本 ◆ 无可动部件,不堵塞◆ 安装简单,单点插入,支持不断流、在线带压安装 ◆ 多路输出信号:4-20mA 电流、脉冲输出 ◆ 智能自诊断,降低产品维护成本 ◆ 支持多种通信方式(HART 、Modbus-RTU )目录1概述 (3)1.1测量原理 (3)1.2 产品概述 (4)2参数 (5)3材料 (8)4 安装 (8)4.1安装直管段要求 (8)4.2流量计插入管道方向选择 (10)5 仪表尺寸和外形结构 (11)5.1仪表尺寸和外形结构 (11)5.2卡套球阀连接流量计的G1/2”焊接基座 (14)5.3 分体式流量计表头 (14)产品数据手册Rev1.0 Date:3/03/2015 Data sheets产品数据手册 Rev1.0Date:3/03/2015Data sheets 1 概述1.1测量原理TGF450系列热式气体质量流量计为恒功率型热式气体质量流量计,基于热传导技术原理,采用牛顿热力学定律,以实现对气体质量流量的测量。
TGF450流量计的测量元件由两个铂电阻传感元件和一个加热元件构成(如图1.1),它们被置于流体中。
测量时,一个传感元件由加热功率为P的加热元件进行加热,使其温度升至T1;另一传感元件不被加热,以用于测量介质温度,设为T2,因此两个传感元件之间将产生温差△T=T1-T2。
当流量为零时,△T最大,随着流量Q的增大,传感元件的热量被带走,从而温度T1下降,则△T减小。
根据牛顿热力学定律,加热功率P、温差△T与质量流量Q之间满足下式:P/△T=K1+K2*F(Q)K3上式中K1、K2、K3是与气体物理性质有关的参数, P为恒定加热功率,△T为传感元件的温差,F(Q)为质量流量与温差△T满足的函数关系式,Q为质量流量。
科氏力质量流量测量系统Promass80_83

电流输出 频率输出
电流输出Ex i 有源 HART 电流输出Ex i 无源 HART
电流输出 HART
电流输出 HART
电流输出 HART
电流输出 HART
电流输出 HART
电流输出 HART
电流输出 HART
电流输出 HART
7
电气连接 分离型
gry=灰色 grn=绿色 yel=黄色 pnk=粉红色 wht=白色 brn=褐色
的空气
最大可能满量程值
mmax(G)
= mmax(F) (G) = 7 0 0 0 0 k g / h 6 0 . 3 k g / m=3 2 6 4 0 0
1 6 0 k g / m3
1 6 0 k g / m3
kg/h
推荐测量范围 见P15 流量限值
量程比 大于1000:1 流量超过预设的满量程值时不会使放大器过载 如 累积量值的正确记录
无源 0 / 4 . . . 2 0 m A R i 150 Umax= 3 0 V DC
4
输出
输出信号
Promass80
电流输出
有源/无源可选 电气隔离 时间常数可选 0.05...100s
满量程值可选 温度系数 0.005% o.r./
分辨率 0.5 A
有源 0/4...20mA RL 700 HART RL 250 无源 4...20mA max.30V DC Ri 150
有源 24V DC 25mA(max.250mA/20ms) RL 100 无源 集电极开路 3 0 V DC 000Hz(fmax=12500Hz) 开关比1:1 脉宽max.10s 脉冲输出 脉冲值和脉冲极性可选 最大脉冲宽度可调 0.05...2s 频率 1 / ( 2 脉宽)时 开关比1:1
维萨拉 DRYCAP 传感器技术系列产品说明书

无论您的应用范围是什么,您都会从维萨拉产品组合中找到适合的露点仪。所有维 萨拉传感器均能耐受污染物,如水溅、环境湿度、压缩机油和化学杂质。
每款产品的测量范围
Optimal measurement range for each product
手Ha持nd式-露he点ld和de温w度p仪oi表nt and temperature meter
关于
维萨拉
参考编号 B212711ZH-A ©Vaisala 2023
维萨拉是一家环境和测量技术领域的设备生产商。凭借将近 90 年的经验,维萨拉为世界更美好而进行观测。我们是客户的可靠合 作伙伴,能够提供观测和测量产品及服务。维萨拉总部位于芬兰,在全球拥有超过 2,000 名专业人员,公司在纳斯达克赫尔辛基证 券交易所上市。
• 维萨拉第一台将露点和压力测量 相结合的变送器
• 与维萨拉手持式仪表 Indigo80 兼容,方便抽检、本地显示和数 据记录
• 压力高达 12 bar • DRYCAP® 和 BAROCAP®
传感器技术
• 测量范围可以低至 -80 °C • 压力高达 50 bar • DRYCAP® 传感器技术
4
相关产品
INDIGO80 手持式显示表头配 DMP80
适用于现场采样和校准、数据分析和诊断
访问 /compressedair 了解有关可用仪器和配件的更多信息。 如有任何问题,请随时与我们联系。
远程显示屏
连接电缆
• 露点测量范围宽 • 双探头、高精度便携式诊断和数据记录工具 • 行业标准 USB-C 接口 • 基于菜单的交互式多语言用户界面
IInnddigigoo8800w与ithDDMMPP8800
美国 MEAS传感器 说明书

工业机器和设备应用
生产过程控制,阀门和流量控 制,气缸控制,网前箱(纸和 纸浆) 校巴停靠信号控制 空压机控制,喷涂设备,闭环 反馈,泵控系统,恒压供水 手持式压力表,气相色谱仪 机械人, 称重, 产品验证 冲压机动荷载测力器
测试与测量仪器
测试与测量仪器需要高精度、高 稳定的传感器。由于Schaevitz®, ATEX和Entran®优异的品质使得美国 MEAS传感器一直是那些追求高精度 传感器客户的理想供应商。最近,美 国MEAS传感器在芯片稳定性方面的 改进,使超稳压力传感器和超稳压力 变送器跻身于特殊环境下的测试与测 量等应用领域。
位移和倾角传感器 运动传感器 Humirel 相对湿度传感器
热电堆 热敏电阻
运动传感器 声学传感器 振动传感器 超声波传感器 数字按键键盘 血氧探头 (SPO2)
医疗应用
一次性血压传感器,通风设备, 呼吸器,睡眠呼吸暂停传感器,
气压表,监护仪,麻醉机,呼吸机 注射泵,球囊成形术,眼外科, 低温成形术,脊柱测试
产线
位置
位置 位置
压力 压力 湿度 温度
振动 振动
振动 压电薄膜 力
传感器/产品类型
Schaevitz®LVDT、角 位 移 传 感器 Schaevitz®RVIT传感器 不锈钢隔离式压力变送器 (充油型)
板装式压力传感器 不锈钢隔离式压力传感器 (充油型) 相对湿度和温度传感器 NTC热敏电阻
加速度计
非破坏性测试 汽车安全带拉力, 称重和测量
工业解决方案 商业建筑和设备
美国MEAS传感器可为商业建筑业厂家提供服务,尤其是在供暖、通风和制冷领域。由 于我们的全密封结构微熔技术压力传感器可在恶劣环境中正常工作,故该产品为暖通、空调 和制冷厂家提供了理想的解决方案。
一诺LZYN质量流量计使用说明书 2009版

安装使用产品前 请阅读使用说明书
上海一诺仪表有限公司
目 录 第 1 章 科里奥利质量流量计简介.......................................................................................................................... 1 1.1 科里奥利质量流量计...................................................................................................................................1 1.2 科里奥利质量流量计原理.......................................................................................................................... 1 1.3 科里奥利质量流量计的特点...................................................................................................................... 1 第 2 章 技术指标.......................................................................................................................................................1 2.1 性能规格...............
哈希公司水质监测仪器说明书

哈希公司成立于1947年,现为美国丹纳赫集团一级子公司,总部设在美国科罗拉多州的拉夫兰市,是设计和制造水质、水文监测仪器的专业厂家。
工厂分别分布于美国、瑞士、德国、法国和英国。
作为水质、水文监测仪器的世界领导者,哈希公司产品被全球用户广泛应用于饮用水、地下水、地表水、市政污水、工业污水、半导体超纯水、制药/电力及其他工业净水、等领域,其全线产品系列涵盖实验室定性/定量分析、现场分析、流动分析测试、在线分析测试。
产品具有测量精确、运行可靠、操作简单、低维护量,结构紧凑等特点。
哈希公司一直致力于使水质分析过程更方便、更迅捷、更可靠:各类包装的即开即用型化学试剂包,不仅为精确的化学分析提供了可靠的质量保障,也为用户节约了宝贵的时间和人力资源,成为了中国环境现场应急监测的首选工具;各种类型的在线水质分析仪器,以其准确度高、维护量小、可测量的水质参数多等特点,可以满足污水处理厂、饮用水厂、工业过程水处理、工业污染源、水质自动监测站等不同场合的应用。
哈希公司的水质分析仪器产品在中国已经有超过20年的成功应用, 哈希在线水质分析仪器在中国水处理市场以及全球范围内都得到了广泛的应用,一直以来哈希在线浊度分析仪都是饮用水行业关键性运行指标-浊度测试的常用仪器。
我们的目标是继续为广大用户提供可靠的仪器、测试方法、简单的操作步骤和优质的客户服务,不断地提高产品的质量以满足客户需求不断变化的需要。
目前公司已经在北京、上海、广州和重庆、沈阳、西安、武汉、济南、南京、福州设立了办事处,为中国的广大客户提供方便、周到的服务。
目录水位监测 (2)流量监测 (12)雨量监测 (29)气象监测 (31)水质监测 (33)典型应用 (60)基本介绍用于连续测量水位的精巧型气泡水位计。
它具有高量程、高精度的特点,并带有4-20 mA 模拟输出和SDI12标准接口,最新设计的智能型气泵可以在满足测量精度的前提下减小打气体积,以便节省系统功耗。
Proline Promass 80A, 83A 科氏流量计说明书

TI00054D/28/zh/13.12技术资料Proline Promass 80A, 83A科氏力质量流量测量系统单管测量系统,用于极小流量的高精度测量应用根据科氏力测量原理,测量完全不受流体物理特性(例如:粘度和密度)的影响。
•加料和灌装过程中的极小流量的连续流量测量•高压和低压条件下的液体(例如:乳液、添加剂、食用香料、胰岛素)和气体的高精度测量•流体温度可达+ 200 °C (+ 392°F)•过程压力可达400 bar (5800 psi)防爆认证:•ATEX 、FM 、CSA 、TIIS 、IECEx 、NEPSI 食品行业/卫生型领域中认证:•3A 、FDA 、EHEDG与过程控制系统的连接接口:•HART 、PROFIBUS DP/PA 、基金会现场总线(FF)、MODBUS测量系统的安全性:•压力设备指令、SIL-2•充气连接或爆破片(可选)优势在不同过程条件下,Promass 系列流量计均可在测量过程中同时完成多个过程变量(质量、密度、温度)的测量。
Proline 系列变送器具有下列优点:•采用模块化结构设计和操作方法,变送器具有更高的测量效率•扩展软件包可提供批量控制和浓度测量功能,扩展了仪表的使用范围•变送器自带诊断和数据备份功能,有效提升了过程生产的质量Promass 系列传感器历经数100000次应用验证,具有下列优点:•一体式结构设计的多变量流量测量传感器•平衡单管测量系统,抗振性强•结构坚固,能有效抵消外部管路的压力•无需考虑前后直管段长度,安装简便Proline Promass 80A, 83A2Endress+Hauser目录功能与系统设计 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3测量原理 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3测量系统 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4输入 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5测量变量 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5测量范围 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5量程比 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5输入信号 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5输出 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6输出信号 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6报警信号 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8负载 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8小流量切除 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8电气隔离 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8开关输出 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8电源 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9测量单元的电气连接 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9接线端子分配 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10分体式仪表的电气连接 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11供电电压 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11电缆入口 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11电缆规格(分体式仪表) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11功率消耗 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12电源故障 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12电势平衡 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12性能参数 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13参考操作条件 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13最大测量误差 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13重复性 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14介质温度的影响 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15介质压力的影响 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15设计准则 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15安装条件 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16安装指南 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16前后直管段 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18连接电缆长度 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18系统压力 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18环境条件 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19环境温度范围 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19储存温度 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19气候等级 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19防护等级 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19抗冲击性 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19抗振性 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19CIP 清洗 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19SIP 清洗 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19电磁兼容性(EMC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19过程条件 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20介质温度范围 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20介质压力范围(标称压力) . . . . . . . . . . . . . . . . . . . . . . . . . . . 20爆破片(可选) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20限流值 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20压损(公制(SI)单位) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21机械结构 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23设计及外形尺寸 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23重量 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36材料 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36材料负载曲线 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37过程连接 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38人机界面 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39显示单元 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39操作单元 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39语言组 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39远程操作 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39证书和认证 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40CE 认证 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40C-Tick 认证 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40防爆认证(Ex) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40卫生型认证 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40基金会现场总线(FF)认证 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40PROFIBUS DP/PA 认证 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40MODBUS 认证 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40其他标准和准则 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40压力设备指令 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41功能安全性 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41订购信息 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42附件 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42文档资料 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42注册商标 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43Proline Promass 80A, 83A功能与系统设计测量原理测量系统基于科氏力测量原理工作。
智能LDCK型电磁流量计使用说明书+上海九

1.2 2.5 4.5 7 12 20 30 50 70 110 180 250 450 700 1000 1400 1800 2300 2800 4000 5500 7200 9100 11300 16000
1.5 3 6 9 15 25 35 60 90 140 220 300 550 880 1300 1700 2250 2800 3500 5000 7000 9000 11500 14000 20000
0.1 0.2 0.4 0.6 0.9 1.5 2.5 3.6 5.5 8.5 13.5 20 35 55 80 105 140 180 220 310 420 550 700 900 1300
0.3 0.6 1.2 1.8 3 4.5 7 12 18 28 45 65 115 180 250 350 450 570 700 1000 1400 1800 2300 2800 4000
所有仪表在出厂前,都按用户订货时提出的量程,用水进行实流标定,量程设定都已调整 完毕。用户除检查零位外,不需任何调整,即可投入使用。若试运行时发生问题,请与本公司 联系。
本使用说明书用于上海自仪九仪表有限公司设计、生产的LDCK型电磁流量计 的安装、使用与维护。
公司地址:上海市嘉定区安亭镇昌吉路157号 营 销 部:021-59577980 021-59577910 传 真:021-59564732 邮 编:201805
注: 1、表中的 Qmin 为最小流量,其流速为 0.3(m/S);最大流量为 Qmax。 2、表中的 Q1、Q2、Q3、……Qmax 为流速在 1、2、3、……10 (m/s)时的流量。
3、用户使用的最大流量可在 Q1~Qmax 范围内选择其中一个流量值,
4、流量计算公式:Q =Vπ(D/2)2=0.002826D2×V (式中:流量Q:m3/h;流速V:m/s;公称通经D:mm) 5、流速范围:0.3~10(m/s),〔扩大范围 0.1~15(m/s)为特殊供货〕。