管道跨距计算表
煤气管道跨距计算汇总
1 / 17表1 管道按刚度条件跨距计算汇总2.挠度计算公式均按以下单位输入:L---管道跨距(mm);q c ---管道操作载荷(N/mm ); E----弹性模量(MPa ,N/mm 2); J-----惯性矩(mm 4); m ax f ---最大挠度(mm )为边跨跨中最大挠度L---管道跨距(m);qc---管道操作载荷(N/m ); E----弹性模量(MPa,N/mm 2); J-----惯性矩(mm 4);L---管道跨距(m);qc---管道操作载荷(kg/m ); E----弹性模量(MPa ); J-----惯性矩(cm 4);5.跨距计算时挠度均取15mm.6.黑框内是推荐使用公式。
表2 管道按强度条件跨距计算汇总2.弯距计算公式均按以下单位输入:L---管道跨距(m);q b---管道计算载荷(N/m);M max----最大计算弯矩(N·m);L---管道跨距(m);q b---管道计算载荷(N/m);M max----最大计算弯矩(N·m);[σ]t----管道使用温度下许用应力(MPa);W-----管道抗弯截面模量(mm3).公式;5. 考虑内压2为管道考虑最不利情况θσσ=t][;6.黑框内是推荐使用公式。
2 / 17具体推导如下:一.单跨连续梁:1. 挠度计算公式:m ax f EJL q c 38454=(建筑结构静力计算手册92页)其中可全部采用国际制单位:L---管道跨距(mm);q c ---管道操作载荷(N/mm ); E----弹性模量(MPa ,N/mm 2); J-----惯性矩(mm 4); m ax f ---最大挠度(mm ) 如采用以下单位:L---管道跨距(m);q c ---管道操作载荷(N/m ); E----弹性模量(MPa,N/mm 2); J-----惯性矩(mm 4); m ax f ---最大挠度(mm )m ax f ==42||||384||||5/4/mm mm N mm mm N c J E L q 42||||3841010||||5/1234/mm mm N m m N c J E L q ⨯⨯- EJL q f c 47max10302.1⨯=2. 跨距计算: L=47max10302.1cq EJf ⨯ 挠度m ax f 取15mm; L=0.0334cq EJ其中:L---管道跨距(m);q c ---管道操作载荷(N/m ); E----弹性模量(MPa,N/mm 2); J-----惯性矩(mm 4); 如采用以下单位:L---管道跨距(m);q c ---管道操作载荷(kg/m ); E----弹性模量(MPa ); J-----惯性矩(cm 4)L=0.0334/||||mN c mmq J E = 0.0334/481.9||10||⨯⨯m kg c cm q J E=0.033×5.654/||||m kg c cm q J E =0.194/||||mkg c cmq J EL==0.194cq EJ 二.两跨连续梁:1. 挠度计算公式:m ax f EJL q c 100521.04=(建筑结构静力计算手册150页,表3-2)其中可全部采用国际制单位:L---管道跨距(mm);q c ---管道操作载荷(N/mm ); E----弹性模量(MPa ,N/mm 2); J-----惯性矩(mm 4); m ax f ---最大挠度(mm ) 如采用以下单位:L---管道跨距(m);q c ---管道操作载荷(N/m ); E----弹性模量(MPa,N/mm 2); J-----惯性矩(mm 4); m ax f ---最大挠度(mm )m ax f ==42||||100||||521.0/4/mm mm N mm mm N c J E L q 42||||1001010||||521.0/1234/mm mm N m m N c J E L q ⨯⨯- EJL q f c 47max10521.0⨯=2. 跨距计算: L=47max10521.0cq EJf ⨯挠度m ax f 取15mm; L=0.0414cq EJ 其中:L---管道跨距(m);q c ---管道操作载荷(N/m ); E----弹性模量(MPa,N/mm 2); J-----惯性矩(mm 4); 如采用以下单位:L---管道跨距(m);q c ---管道操作载荷(kg/m ); E----弹性模量(MPa ); J-----惯性矩(cm 4)L=0.0414/||||mN c mmq J E = 0.0414/481.9||10||⨯⨯m kg c cm q J E=0.041×5.654/||||m kg c cm q J E =0.234/||||mkg c cmq J EL=0.234cq EJ 三.三跨连续梁:其中可全部采用国际制单位:L---管道跨距(mm);q c ---管道操作载荷(N/mm ); E----弹性模量(MPa ,N/mm 2); J-----惯性矩(mm 4); m ax f ---最大挠度(mm ) 如采用以下单位:L---管道跨距(m);q c ---管道操作载荷(N/m ); E----弹性模量(MPa,N/mm 2); J-----惯性矩(mm 4); m ax f ---最大挠度(mm )m ax f 42||||100||||677.0/4/mm mm N mm mm N c J E L q ==42||||1001010||||677.0/1234/cm mm N m mm N c J E L q ⨯⨯-EJL q f c 47max10677.0⨯=2. 跨距计算: L=47max10677.0cq EJf ⨯ 挠度m ax f 取15mm; L=0.0394cq EJ其中:L---管道跨距(m);q c ---管道操作载荷(N/m ); E----弹性模量(MPa,N/mm 2); J-----惯性矩(mm 4); 如采用以下单位:L---管道跨距(m);q c ---管道操作载荷(kg/m ); E----弹性模量(MPa ); J-----惯性矩(cm 4)L=0.0394/||||mn c mmq J E = 0.0394/481.9||10||⨯⨯m kg c cm q J E=0.039×5.654/||||m kg c cm q J E =0.224/||||mkg c cmq J EL=0.224cq EJ 四.四跨连续梁:1. 挠度计算公式:m ax f EJL q c 100632.04=(建筑结构静力计算手册153页,表3-2)其中可全部采用国际制单位:L---管道跨距(mm);q c ---管道操作载荷(N/mm ); E----弹性模量(MPa ,N/mm 2); J-----惯性矩(mm 4); m ax f ---最大挠度(mm ) 如采用以下单位:L---管道跨距(m);q c ---管道操作载荷(N/m ); E----弹性模量(MPa,N/mm 2); J-----惯性矩(mm 4); m ax f ---最大挠度(mm )m ax f ==42||||100||||632.0/4/mm mm N mm mm N c J E L q 42||||1001010||||632.0/1234/mm mm N m m N c J E L q ⨯⨯- EJL q f c 47max10632.0⨯=2. 跨距计算: L=47max10632.0cq EJf ⨯ 挠度m ax f 取15mm; L=0.0394cq EJ其中:L---管道跨距(m);q c ---管道操作载荷(N/m ); E----弹性模量(MPa,N/mm 2); J-----惯性矩(mm 4); 如采用以下单位:L---管道跨距(m);q c ---管道操作载荷(kg/m ); E----弹性模量(MPa ); J-----惯性矩(cm 4)L=0.0394/||||mn c mmq J E = 0.0394/481.9||10||⨯⨯m kg c cm q J E=0.039×5.654/||||m kg c cm q J E =0.224/||||mkg c cmq J EL=0.224cq EJ 五.五跨连续梁:1. 挠度计算公式:m ax f EJL q c 100644.04=(建筑结构静力计算手册157页,表3-2)中可全部采用国际制单位:L---管道跨距(mm);q c ---管道操作载荷(N/mm ); E----弹性模量(MPa ,N/mm 2); J-----惯性矩(mm 4); m ax f ---最大挠度(mm ) 如采用以下单位:L---管道跨距(m);q c ---管道操作载荷(N/m ); E----弹性模量(MPa,N/mm 2); J-----惯性矩(mm 4); m ax f ---最大挠度(mm )m ax f ==42||||100||||644.0/4/mm mm N mm mm N c J E L q 42||||1001010||||644.0/1234/mm mm N m m N c J E L q ⨯⨯- EJL q f c 47max10644.0⨯=2. 跨距计算: L=47max10644.0cq EJf ⨯挠度m ax f 取15mm;L=0.0394cq EJ 其中:L---管道跨距(m);q c ---管道操作载荷(N/m ); E----弹性模量(MPa,N/mm 2); J-----惯性矩(mm 4); 如采用以下单位:L---管道跨距(m);q c ---管道操作载荷(kg/m ); E----弹性模量(MPa ); J-----惯性矩(cm 4)L=0.0394/||||mn c mmq J E = 0.0394/481.9||10||⨯⨯m kg c cm q J E=0.039×5.654/||||m kg c cm q J E =0.224/||||mkg c cmq J EL=0.224cq EJ 强度校核: 一.单跨简支梁: 1. 弯矩计算公式:m ax M =82L q b (建筑结构静力计算手册92页)其中:L---管道跨距(m);q b ---管道计算载荷(N/m );M max ----最大计算弯矩(N ·m );2. 弯曲应力计算公式:σL =WM max =W L q b 81023(不考虑内压)其中:L---管道跨距(m);q b ---管道计算载荷(N/m ); M max ----最大计算弯矩(N ·m );σL ----管道中最大弯曲应力(最大纵向应力)(MPa ); W-----管道抗弯截面模量(mm 3).3. 不考虑内压跨距计算:bt q W L 310][8σ•==b t q W ][089.0σ(不考虑内压) 4. 考虑内压跨距计算:4.1 内压引起的应力:σL δ40PD =σθδ20PD =σL ----内压产生的纵向应力(MPa );σθ----内压产生的环向应力(MPa );P ----管道内压 (MPa );D 0 ----管道内径 (mm );δ ----管道壁厚 (mm );4.2 管道存在压力时的纵向合成应力:σ=σL +σθ/2=WL q b 81023+0.5σθ 内压引起的纵向应力为压力引起的环向应的一半;4.3 考虑内压时管道跨距计算:bt q W L 310)5.0]([8θσσ-•= 考虑最不利情况θσσ=t ][:b t bt b t q W q W q W L ][063.010][5.0810)5.0]([833σσσσθ=•=-•=二.两跨简支梁:1. 弯矩计算公式:max W =82ql (建筑结构静力计算手册150页) 其中:L---管道跨距(m);q b ---管道计算载荷(N/m );M max ----最大计算弯矩(N ·m );2. 弯曲应力计算公式:σ=WM max =W L q b 81023(不考虑内压) 其中:L---管道跨距(m);q b ---管道计算载荷(N/m );M max ----最大计算弯矩(N ·m );σ----管道中最大弯曲应力(MPa ); W-----管道抗弯截面模量(mm 3).3. 不考虑内压跨距计算:bt q W L 310][8σ•==b t q W ][089.0σ(不考虑内压) 4. 考虑内压跨距计算:4.1 内压引起的应力:σL δ40PD =σθδ20PD =σL ----内压产生的纵向应力(MPa );σθ----内压产生的环向应力(MPa );P ----管道内压 (MPa ); D 0 ----管道内径 (mm );δ ----管道壁厚 (mm );4.2 管道存在压力时的纵向合成应力:σ=σL +σθ/2=WL q b 81023+0.5σθ 内压引起的纵向应力为压力引起的环向应的一半;4.3 考虑内压时管道跨距计算:bt q W L 310)5.0]([8θσσ-•= 考虑最不利情况θσσ=t ][:b t bt b t q W q W q W L ][063.010][5.0810)5.0]([833σσσσθ=•=-•= 三.三跨简支梁:1. 弯矩计算公式:m ax M =102ql (建筑结构静力计算手册151页) 其中:L---管道跨距(m);q b ---管道计算载荷(N/m );M max ----最大计算弯矩(N ·m );2. 弯曲应力计算公式:σ=WM max =W L q b 101023(不考虑内压) 其中:L---管道跨距(m);q b ---管道计算载荷(N/m );M max ----最大计算弯矩(N ·m );σ----管道中最大弯曲应力(MPa ); W-----管道抗弯截面模量(mm 3).3. 不考虑内压跨距计算:bt q W L 310][10σ•==b t q W ][1.0σ(不考虑内压) 4. 考虑内压跨距计算:4.1 内压引起的应力:σL δ40PD =σθδ20PD =σL ----内压产生的纵向应力(MPa );σθ----内压产生的环向应力(MPa );P ----管道内压 (MPa );D 0 ----管道内径 (mm );δ ----管道壁厚 (mm );4.2 管道存在压力时的纵向合成应力:σ=σL +σθ/2=WL q b 81023+0.5σθ 内压引起的纵向应力为压力引起的环向应的一半;4.3 考虑内压时管道跨距计算:bt b t q W q W L )5.0]([1.010)5.0]([103θθσσσσ-=-•= 考虑最不利情况θσσ=t ][:b t bt b t q W q W q W L ][071.010][5.01010)5.0]([1033σσσσθ=•=-•= 四.四跨简支梁:1. 弯矩计算公式:2max 107.0ql M =(建筑结构静力计算手册153页) 其中:L---管道跨距(m);q b ---管道计算载荷(N/m );M max ----最大计算弯矩(N ·m );2. 弯曲应力计算公式:σ=WM max =W L q b 3210107.0⨯(不考虑内压) 其中:L---管道跨距(m);q b ---管道计算载荷(N/m );M max ----最大计算弯矩(N ·m );σ----管道中最大弯曲应力(MPa );W-----管道抗弯截面模量(mm 3).3. 不考虑内压跨距计算:bt q W L 310107.0][⨯=σ=b t q W ][097.0σ(不考虑内压) 4. 考虑内压跨距计算:4.1 内压引起的应力:σL δ40PD =σθδ20PD =σL ----内压产生的纵向应力(MPa );σθ----内压产生的环向应力(MPa );P ----管道内压 (MPa );D 0 ----管道内径 (mm );δ ----管道壁厚 (mm );4.2 管道存在压力时的纵向合成应力:σ=σL +σθ/2=WL q b 81023+0.5σθ 内压引起的纵向应力为压力引起的环向应的一半;4.3 考虑内压时管道跨距计算:bt q W L 310107.0)5.0]([⨯-=θσσ 考虑最不利情况θσσ=t ][:bt b t b t q W q W q W L ][068.010107.0][5.010107.0)5.0]([33σσσσθ=⨯=⨯-= 五.五跨简支梁:1. 弯矩计算公式:2max 0.105M ql =(建筑结构静力计算手册153页) 其中:L---管道跨距(m);q b ---管道计算载荷(N/m );M max ----最大计算弯矩(N ·m );2. 弯曲应力计算公式:σ=WM max =230.10510b q L W ⨯(不考虑内压) 其中:L---管道跨距(m);q b ---管道计算载荷(N/m );M max ----最大计算弯矩(N ·m );σ----管道中最大弯曲应力(MPa );W-----管道抗弯截面模量(mm 3).3. 不考虑内压跨距计算:L =4. 考虑内压跨距计算:4.1 内压引起的应力:σL δ40PD =σθδ20PD =σL ----内压产生的纵向应力(MPa );σθ----内压产生的环向应力(MPa );P ----管道内压 (MPa ); D 0 ----管道内径 (mm );δ ----管道壁厚 (mm );4.2 管道存在压力时的纵向合成应力:σ=σL +σθ/2=WL q b 81023+0.5σθ 内压引起的纵向应力为压力引起的环向应的一半;4.3 考虑内压时管道跨距计算:L = 考虑最不利情况θσσ=t ][:L ===。
管道跨距
1 总则1.0.1 本标准适用于石油化工装置内的管道设计。
1.0.2 执行标准时,尚应符合现行有关标准规定的要求。
1.0.3 本标准中所列的管道跨距是按照我院工程设计标准《装置内管道跨距的计算方法》(B C3-5-1-96)编制的。
1.0.4 本标准所列的管道跨距只供连续跨均布载荷下的水平直管使用。
对于带末端跨的水平直管、水平弯管、水平Ⅱ型管、带垂直管段的Z型管和有集中载荷的水平直管的允许跨距,应按《装置内管道跨距的计算方法》(B C3-5-1-96)中的有关规定确定。
1.0.5 本标准代替《管线的跨距(B A3-3-10-90)和《装置内管线的基本跨距》(BA3-7-2-84)。
2 编制的原始数据2.0.1 本标准所列管道的跨距,按下列基本数据计算确定。
操作温度:T=250℃管材:20号钢]=110MP a(壁厚≤16m m)许用应力:[σ250℃]=104M Pa(壁厚=17~40mm)[σ250℃=1.864×105MPa弹性模数:E250℃3 管道的跨距3.0.1 无缝钢管不保温管道允许跨距见表3.0.1。
3.0.2 L G级大直径焊接钢管不保温管道允许跨距见表3.0.2。
3.0.3 S TD级大直径焊接钢管不保温管道允许跨距见表3.0.3。
3.0.4 X S级大直径焊接钢管不保温管道允许跨距见表3.0.4。
3.0.5 S CH20无缝钢管保温管道允许跨距见表3.0.5。
3.0.6 S CH40无缝钢管保温管道允许跨距见表3.0.6。
3.0.7 S CH80无缝钢管保温管道允许跨距见表3.0.7。
3.0.8 L G级大直径焊接钢管保温管道允许跨距见表3.0.8。
3.0.9 S TD级大直径焊接钢管保温管道允许跨距见表3.0.9。
3.0.10XS级大直径焊接钢管保温管道允许跨距见表3.0.10。
表3.0.1无缝钢管不保温管道允许跨距表表3.0.2L G级大直径焊接钢管不保温管道允许跨距表表3.0.3ST D级大直径焊接钢管不保温管道允许跨距表表3.0.4X S级大直径焊接钢管不保温管道允许跨距表表3.0.5S CH20无缝钢管保温管道允许距表续表3.0.5续表3.0.5续表3.0.5续表3.0.5续表3.0.5续表3.0.5续表3.0.5续表3.0.5续表3.0.5续表3.0.5续表3.0.5续表3.0.5表3.0.6sch40无缝钢管保温管道允许跨距表续表3.0.6续表3.0.6续表3.0.6续表3.0.6续表3.0.6续表3.0.6续表3.0.6续表3.0.6续表3.0.6续表3.0.6续表3.0.6续表3.0.6表3.0.7 SC H80无缝钢管保温管道允许跨距表3.0.7 SC H80无缝钢管保温管道允许跨距表续表3.0.7续表3.0.7续表3.0.7续表3.0.7续表3.0.7续表3.0.7续表3.0.7续表3.0.7续表3.0.7续表3.0.7续表3.0.7表3.0.8 LG级大直径焊接钢管保温管道允许跨距表续表3.0.8续表3.0.8续表3.0.8表3.0.9 STD大直径焊接钢管保温管道允许跨距表续表3.0.9续表3.0.9。
管道跨度计算
管道最大允许跨度的校核计算河南省焦作市水务有限责任公司殷磊秦海霞摘要:在供水管道跨越距离基本计算公式的基础上,对计算数值在实际施工中的应用作进一步的研究,主要解决在施工过程中应注意的问题及如何保证跨越管道的安全。
关键词:供水管道;跨越距离;施工方法在管道工程的设计施工中,不可避免地会遇到各种障碍物,如铁路、公路、河流、沟壑等等[1]。
为了保证管道工程的顺利施工,对这些障碍物,我们可以根据现场情况采取跨越或穿越等方式进行。
因此,管道的最大允许跨度决定了管道跨越障碍物的距离。
管道的跨越距离不能凭经验确定,必须要经过一定的计算,才能从技术上完全保证管道跨越的安全性。
以下从管道强度方面进行计算。
1、基本计算公式为保证管道跨越距离的安全,管道断面上的最大应力不得超过管材的许用应力。
即:管材的强度应大于管道上所有荷载的垂直作用力。
其基本计算公式如下:1.1对于连续敷设的水平直管(见图1)式1L=1.2 对于尽端直管(见图2)式2L=1.3 对于水平弯管 (见图3)L =式3说明:[]σω---许用外载综合应力。
在最大压力条件下[]σω=46mpa 。
ϕ -----焊缝系数。
见表1W -----管道抗弯截面系数。
见表2。
q -----单位长度计算重量表1—管道横向焊接系数表2--管道抗弯系数2、工程实例2.1、东环路管道工程东环路管道工程采用DN400mm球墨铸铁管敷设,全长1850米。
途中需跨越一条小河,水面宽8米,梯形护坡,河面宽10米。
跨越管采用A2钢、规格为Ø400×8mm。
按式1进行理论计算后,得出跨越距离为15米。
从理论数据上判断此次跨越可行。
管道支座采用混凝土现浇,预埋钢制“U”构件用于固定管道,防止管道发生侧向位移。
管道防腐采用三油两布。
管道对焊使用单面坡口焊接,在接口处加焊6根均匀分布的“一”字形钢板。
接口处基本位于河面中点,两端采用套筒方式与球墨铸铁管相连。
经打压试验及实际运行,没有发生问题。
管道跨距计算
按强度条件管道截面系数W(cm 3)σt:钢管热态许用应力MPa管道横向焊缝系数计算温度下钢材弹性模量Et(MPa)按刚度条件管道截面二次炬I(cm 4)按强度条件按刚度条件Lmax Lmax 外径壁厚保温层厚度管道重量保温层重17.421.41020.0010.00150.00247.527.617.120.5920.0010.00150.00223.025.217.119.6820.0010.0050.00198.5 6.816.118.1720.009.0050.00156.8 6.015.116.6630.008.0050.00121.9 5.314.715.4529.008.0050.00102.1 4.513.814.3478.007.0050.0080.8 4.114.113.9426.008.0050.0081.9 3.713.212.8377.007.0050.0063.5 3.412.811.9325.007.0050.0054.5 2.912.811.2273.008.0050.0051.9 2.512.010.0219.008.0050.0041.4 2.19.67.7159.00 4.5050.0017.0 1.69.17.0133.00 4.5050.0014.2 1.4按强度条件Lmax q Wφ[σ]t14.52430.691078194.0按刚度条件Lmax q Et Ji 013.52430.69192000229530.03max10019.0qIi E L t =[]qW L tσφ24.2max=管道重量外径壁厚保温层厚度管道重量保温层重426.008.00130.0081.934.1Lmax Lmax外径壁厚保温层厚度管道重量保温层重16.320.51020.0010.00150.00385.733.116.319.8920.0010.00150.00313.130.316.519.2820.0010.0050.00248.88.215.417.5720.009.0050.00209.07.314.616.2630.008.0050.00154.1 6.414.415.2529.008.0050.00114.2 5.513.113.8478.007.0050.00108.6 5.013.713.7426.008.0050.0094.0 4.512.612.4377.007.0050.0081.2 4.012.211.5325.007.0050.0069.5 3.512.711.2273.008.0050.0051.7 3.012.210.1219.008.0050.0038.9 2.58.97.4159.00 4.5050.0022.1 2.08.4 6.7133.00 4.5050.0018.5 1.74.2 3.258.00 4.5040.0018.50.75.6 4.378.00 4.5040.0018.50.97.3 5.7108.00 4.5050.0018.5 1.5Lmax Lmax外径壁厚保温层厚度管道重量保温层重30.533.01220.0012.00150.00385.738.724.325.9920.0010.00150.00313.130.324.925.2820.0010.0050.00248.88.224.023.6720.0010.0050.00209.07.321.821.1630.008.0050.00154.1 6.421.219.6529.008.0050.00114.2 5.518.717.4478.007.0050.00108.6 5.019.217.1426.008.0050.0094.0 4.517.215.2377.007.0050.0081.2 4.016.113.9325.007.0050.0069.5 3.516.613.4273.008.0050.0051.9 3.015.011.6219.008.0050.0041.4 2.512.49.2159.00 4.5050.0017.0 2.011.48.2133.00 4.5050.0014.2 1.7 10.17.1108.00 4.0050.0010.2 1.5 9.2 6.289.00 4.0050.008.3 1.3 8.4 5.676.00 4.0050.007.1 1.2 7.2 4.557.00 4.0050.00 5.2 1.0σt:钢管热态许用应力MPa钢材弹性模量Et(MPa)管道放水坡度i0m4)150.0水重总重(Kg/m)总重q(N/m)Et(MPa)I(cm4) 785.41060.510392.5183000.0404637.9636.2884.48666.9183000.0295962.4502.7708.06938.1183000.0208728.2387.0549.95389.0183000.0127051.8296.1423.44149.0183000.075612.4206.7313.43071.1183000.044439.1169.1254.02489.5183000.028728.7132.0217.72133.5183000.022952.9103.5170.31669.1183000.013929.076.0133.51307.9183000.08844.051.9106.41042.3183000.05851.732.475.8743.2183000.02955.417.736.3356.2183000.0652.312.127.7271.3183000.0375.4水重总重(Kg/m)总重(N/m)132.0248.02430.7水重总重(Kg/m)总重q(N/m)Et(MPa)I(cm4) 785.41204.211801.0183000.0404637.9 636.2979.59599.4183000.0295962.4 502.7759.77444.6183000.0208728.2 387.0603.35912.4183000.0127051.8 296.1456.64474.7183000.075612.4 206.7326.33198.2183000.044439.1 169.1282.72770.2183000.028728.7 132.0230.52259.0183000.022952.9 103.5188.71849.4183000.013929.076.0149.01460.2183000.08844.051.9106.61044.9183000.05851.732.473.8723.2183000.02955.417.741.7409.1183000.0652.312.132.3316.5183000.0375.41.921.1207.0183000.027.33.723.1226.7183000.070.47.727.7271.3183000.0196.3水重总重(Kg/m)总重q(N/m)Et(MPa)I(cm4) 168.5593.05810.9183000.0830777.695.4438.84300.0183000.0295962.475.4332.43257.5183000.0208728.257.7385.7274.02685.0183000.0140579.244.4204.92008.2183000.075612.431.0313.1150.7463.81476.5183000.044439.125.4248.8138.9387.71361.6183000.028728.719.8209.0118.3327.31159.2183000.022952.915.5100.7100.7987.3183000.013929.011.4154.184.4238.5827.4183000.08844.07.8114.262.8177.0615.2183000.05851.74.994.048.8142.8477.8183000.02955.42.721.721.7212.2183000.0652.31.869.517.787.2173.5183000.0375.4 1.269.512.982.4126.0183000.0177.0 0.851.910.462.4102.1183000.096.7 0.551.98.860.786.1183000.058.8 0.341.4 6.547.863.6183000.023.5i0W(cm3)焊缝系数σt管道长度管道受力(N)0.0027920.00.70113.00 6.0062355.070.0026422.50.70113.00 6.0052001.190.0025081.90.70113.00 6.0041628.850.0023522.90.70113.00 6.0032334.040.0022396.10.70113.00 6.0024893.960.0021677.10.70113.00 6.0018426.410.0021199.90.70113.00 6.0014937.030.0021075.70.70113.00 6.0012801.150.002737.60.70113.00 6.0010014.300.002543.30.70113.00 6.007847.250.002427.90.70113.008338.700478 6.006254.030.002269.40.70113.005945.986104 6.004459.490.00281.90.70113.002849.811832 6.002137.360.00256.40.70113.002170.366269 6.001627.77i0W(cm3)焊缝系数σt管道长度管道受力(N)0.0027920.00.70113.00 6.0070805.730.0026422.50.70113.00 6.0057596.130.0025081.90.70113.00 6.0044667.680.0023522.90.70113.00 6.0035474.300.0022396.10.70113.00 6.0026848.130.0021677.10.70113.00 6.0019189.340.0021199.90.70113.00 6.0016620.960.0021075.70.70113.00 6.0013554.080.002737.60.70113.00 6.0011096.470.002543.30.70113.008.0011681.500.002427.90.70113.008358.926988.008358.930.002269.40.70113.005785.9778748.005785.980.00281.90.70113.003272.513002 6.002454.380.00256.40.70113.002532.399696 6.001899.300.0029.40.70113.001656.172057 6.001242.130.00218.00.70113.001813.312008 6.001359.980.00236.30.70113.002170.645302 6.001627.98i0W(cm3)焊缝系数σt管道长度管道受力(N)0.00213595.10.70113.00 6.0034865.620.0026422.50.70113.00 6.0025800.230.0025081.90.70113.00 6.0019544.990.0023898.00.70113.00 6.0016110.250.0022396.10.70113.00 6.0012049.450.0021677.10.70113.00 6.008858.860.0021199.90.70113.00 6.008169.690.0021075.70.70113.00 6.006955.450.002737.60.70113.00 6.005923.990.002543.30.70113.008.006619.230.002427.90.70113.004921.5438418.004921.540.002269.40.70113.003822.2784558.003822.280.00281.90.70113.001697.924266 6.001273.440.00256.40.70113.001388.139355 6.001041.10 0.00232.70.70113.001008.3064778.001008.31 0.00221.70.70113.00816.49660068.00816.50 0.00215.40.70113.00689.1005574 6.00516.83 0.0028.20.70113.00508.5220002 6.00381.39支架接触面积受压力(Pa)MPa0.160.300.051299063.88 1.300.160.300.051083358.20 1.080.160.300.05867267.680.870.160.300.05673625.940.670.160.300.05518624.180.520.160.300.05383883.560.380.160.300.05311188.060.310.160.300.05266690.730.270.160.300.05208631.260.210.160.300.05163484.320.160.160.300.05130292.190.130.160.300.0592906.030.090.160.300.0544528.310.040.100.250.0365110.990.07支架接触面积受压力(Pa)MPa0.160.300.051475119.44 1.480.160.300.051199919.41 1.200.160.300.05930576.620.930.160.300.05739047.930.740.160.300.05559336.000.560.160.300.05399778.010.400.160.300.05346269.970.350.160.300.05282376.740.280.160.300.05231176.500.230.100.300.03389383.500.390.100.250.03334357.080.330.100.250.03231439.110.230.100.250.0398175.390.100.100.250.0375971.990.080.100.250.0349685.160.050.100.250.0354399.360.050.100.250.0365119.360.07支架接触面积受压力(Pa)MPa0.160.300.05726367.120.730.160.300.05537504.780.540.160.300.05407187.280.410.160.300.05335630.210.340.160.300.05251030.240.250.160.300.05184559.500.180.160.300.05170201.800.170.160.300.05144905.260.140.160.300.05123416.360.120.100.300.03220641.030.220.100.250.03196861.750.200.100.250.03152891.140.150.100.250.0350937.730.050.100.250.0341644.180.04 0.100.250.0340332.260.04 0.100.250.0332659.860.03 0.100.250.0320673.020.02 0.100.250.0315255.660.02。
管道跨距计算
公称直径DN (mm)外径DW(mm)壁厚T(mm)内径DI(mm)管子截面惯性矩(cm4)253232611888.7936 323833220830.7098 404533935915.2497 5057 3.55086533.3961 6573 3.566189374.7565 8089481395801.1699 1001084100724438.6140 12513351231688346.9517 15015961473460130.8877 200219720510734416.9820 250273725921195477.8829 300325731136206737.8033 350377736357024073.5949 400426841093967460.6633 4504788462133570015.7235 5005298513181930348.4211 6006308614309551267.7745 7007208704464284731.5722 8008209802771894883.6209 90092099021094056206.8337 100010201010001656556687.3600 120012201012002848297717.7600 140014201014004506909020.1600 160016201016006709559234.5600 180018201018009533417000.9600 2000202010200013055650959.3600 2200222010220017353429749.7600 2400242010240022503922012.1600 2600262010260028584296386.56002800282010280035671721512.9600 3000302010300043843366031.3600公称直径DN (mm)外径DW(mm)壁厚T(mm)内径DI(mm)管子截面抗弯矩(cm3)25323261857.6240 32383322740.8829 40453393990.5833 5057 3.5507590.6488 6573 3.56612970.8737 808948122236.0208 100108410033538.8247 125133512363471.6899 1501596147108809.1474 2002197205245078.0133 2502737259388195.5656 3003257311557026.7354 3503777363756287.4482 40042684101102904.4679 45047884621397175.8967 50052985131719568.5106 60063086142456756.0934 70072087043224199.5248 80082098024706676.1196 90092099025945957.6458 100010201010008120375.9184 1200122010120011673351.3023 1400142010140015869397.9583 1600162010160020708516.15601800182010180026190706.0466 2000202010200032315967.7212 2200222010220039084301.2382 2400242010240046495706.6367 2600262010260054550183.9438 2800282010280063247733.1790 3000302010300072588354.3566管子单位长度荷载(KN/m)管子单位长度自重(KN/m)管子单位长度内容积(m3)26.221521.015740.0005306633.249525.363820.0008038442.149630.436590.0011939964.484345.232150.0019625092.304458.759520.00341946132.655782.130470.00515039 177.4975100.489040.00785000 271.1047154.598530.01187627 388.1599221.752260.01696307 682.1036358.475340.03298963 966.3658449.785090.05265859 1282.5469537.713010.07592599 1640.3742625.640920.10343867 2102.2902807.777310.13195850 2551.9666908.266350.16755354 3033.44791006.822910.20658767 4105.19321202.003560.29594186 5192.59141375.926900.38905856 6716.36541763.147900.50491514 8245.99441980.552080.63867914 10140.60802439.758020.78500000 14012.10242922.87842 1.13040000 18499.66483405.99882 1.53860000 23603.29523889.11922 2.00960000 29322.99364372.23962 2.54340000 35658.76004855.36002 3.14000000 42610.59445338.48042 3.79940000 50178.49685821.60082 4.52160000 58362.46726304.72122 5.30660000刚度条件下的直管跨距67162.50566787.84162 6.15440000 76578.61207270.962027.06500000管子单位长度荷载(KN/m)管子单位长度自重(KN/m)管子单位长度内容积(m3)26.221521.015740.0005306633.249525.363820.0008038442.149630.436590.0011939964.484345.232150.0019625092.304458.759520.00341946132.655782.130470.00515039 177.4975100.489040.00785000 271.1047154.598530.01187627 388.1599221.752260.01696307 682.1036358.475340.03298963 966.3658449.785090.05265859 1282.5469537.713010.07592599 1640.3742625.640920.10343867 2102.2902807.777310.13195850 2551.9666908.266350.16755354 3033.44791006.822910.20658767 4105.19321202.003560.29594186 5192.59141375.926900.38905856 6716.36541763.147900.50491514 8245.99441980.552080.63867914 10140.60802439.758020.78500000 14012.10242922.87842 1.13040000 18499.66483405.99882 1.53860000 23603.29523889.11922 2.00960000强度条件下的直管跨距29322.99364372.23962 2.54340000 35658.76004855.36002 3.14000000 42610.59445338.48042 3.79940000 50178.49685821.60082 4.52160000 58362.46726304.72122 5.30660000 67162.50566787.84162 6.15440000 76578.61207270.962027.06500000管子内介质重量(KN/m)管子内介质密度(KG/m3)钢材在设计温度下的弹性模量(KN/mm2)管子刚度条件下的跨距Lmax(m)5.205774601000.00200.00 3.6757.885670401000.00200.00 3.98511.712992851000.00200.00 4.30319.252125001000.00200.00 4.82133.544902601000.00200.00 5.36150.525276851000.00200.00 5.88777.008500001000.00200.00 6.366116.506159651000.00200.007.076 166.407667651000.00200.007.739 323.628221251000.00200.008.921 516.580718851000.00200.009.693 744.833912851000.00200.0010.324 1014.733303651000.00200.0010.876 1294.512885001000.00200.0011.581 1643.700227401000.00200.0012.047 2026.624993651000.00200.0012.465 2903.189646601000.00200.0013.199 3816.664473601000.00200.0013.773 4953.217523401000.00200.0014.665 6265.442363401000.00200.0015.201 7700.850000001000.00200.0016.013 11089.224000001000.00200.0016.912 15093.666000001000.00200.0017.695 19714.176000001000.00200.0018.391 24950.754000001000.00200.0019.019 30803.400000001000.00200.0019.593 37272.114000001000.00200.0020.121 44356.896000001000.00200.0020.612 52057.746000001000.00200.0021.07160374.664000001000.00200.0021.502 69307.650000001000.00200.0021.910管子内介质重量(KN/m)管子内介质密度(KG/m3)钢材在设计温度下的弹性模量(KN/mm2)管子刚度条件下的跨距Lmax(m)5.205774601000200 3.6507.885670401000200 3.93711.712992851000200 4.21919.252125001000200 4.70433.544902601000200 5.14050.525276851000200 5.61477.008500001000200 5.960116.506159651000200 6.635 166.4076676510002007.260 323.6282212510002008.219 516.5807188510002008.690 744.8339128510002009.036 1014.7333036510002009.310 1294.5128850010002009.931 1643.70022740100020010.146 2026.62499365100020010.324 2903.18964660100020010.607 3816.66447360100020010.805 4953.21752340100020011.478 6265.44236340100020011.643 7700.85000000100020012.270 11089.22400000100020012.515 15093.66600000100020012.700 19714.17600000100020012.84324950.75400000100020012.959 30803.40000000100020013.053 37272.11400000100020013.132 44356.89600000100020013.199 52057.74600000100020013.256 60374.66400000100020013.306 69307.65000000100020013.350设计跨距(m)3.6503.9374.2194.7045.1405.6145.9606.6357.2608.2198.6909.0369.3109.93110.14610.32410.60710.80511.47811.64312.27012.51512.70012.84312.95913.05313.13213.19913.25613.306 13.350。
管道设计数据
4.43
191.6
263.5
1.18
0.0825
400
426
11
112.58
5.01
241.86
319.38
1.34
0.0915
450
五不锈钢管设计数据表
直径
外径x壁厚
管道重量(kg/m)
有保温有集中荷
油漆保温数据
DN
外径d
金属重(kg/m)
无保温(kg/m)
有保温(kg/m)
法兰重(kg/套)
40/32
3.5/3
5/4.5
65
150/125
5/4.5
140
50/25
3.5/3
5/4.5
75
200/100
7/4
150
50/32
3.5/3
5/4.5
75
200/125
7/4.5
150
50/40
3.5/3.5
5/5
75
200/150
7/5
150
65/32
4/3
6/4.5
90
250/125
8/4.5
钢骨架塑料复合管的使用寿命可超过50年,完全符合国际市场的要求。
公称内径(mm)
壁厚e(mm)
(kg/m)
公称压力(Mpa)
允许使用温度
系列Ι
系列Ⅱ
Dn50
11
4
2.5
2.5
-40~80
Dn65
11
5
2.5
2.5
-40~80
Dn80
12
6
2.5
2.5
-40~80
跨距计算原理
2.按强度条件计算允许跨距一般工业管道按强度条件计算允许跨距,如表2-2所示,表2-2 按强度条件计算允许跨度序号项目内容1 计算原则管道自重弯曲应力不应超过管材的许用外载弯曲应力值,以保证管道的安全,根据这原则确定管道允许跨距,称为按强度条件计算的管道允许跨距2 计算方法对于连续敷设、均布荷载的水平直管,如图2-1所示,管道(或管架)的最大允许跨距,可按下列公式计算,即tmax1=2.24[]L Wqφσ(2.1)式中,maxL——管道或管架最大允许跨度m,q——管道单位长度计算荷载(N/m),q=管材重+保温重+附加重,如表2-4、表2-5所示。
W——管道截面抗弯截面系数(cm3,)如表15-15(726/709)所示,φ——管道横向焊缝系数,如表2-6所示3.按刚度条件计算允许跨距一般工业管道按刚度条件计算允许跨距,如表2-3所示,表2-3 按刚度条件计算允许跨度表2-4 不保温管道单位长度计算荷载注:表中,不保温管计算荷载为气管体=(管材重+凝结水重)*9.81液管体=(管材重+管内充满水重)*9.81表2-5 保温管道保温结构单位长度重量(续)注:计算依据:1.100~150℃为室外架空热水采暖管道;2.200~300℃为室外架空蒸汽管道;表2-6 管子强度焊缝系数表4-20常用钢材的弹性模量和线膨胀系数钢号Q235A 10 2020g 16Mn16Mng15MnV15MnVg弹性模量/*105(N/mm2)线膨胀系数设计温度20100150表15-15管道计算数据P49表2-16水平管及尽端直管跨距计算序号项目内容1 水平弯管管道允许跨距水平90°弯管两管道(或管架)间的管道展开长度L(图2-2),规定如下1)一般工业管道不应大于连续敷设的水平直管允许跨距的0.73倍2)石化管道为连续敷设的水平直管允许跨距的0.6~0.7倍2 尽端直管管道允许跨距尽端直管两管架间的管道长度L(图2-3),规定如下:1)一般工业管道不应大于连续敷设的水平直管允许跨距的0.81倍2)石化管道为连续敷设的水平直管允许跨距的0.7~0.8倍。
管道跨距
立管导向支架间的允许间距 气体管道/m 液体管道/m 隔热 光管 隔热 3.4 4 3.4 4 4.6 3.7 4.6 4.9 4Байду номын сангаас3 6.1 6.1 5.5 7 6.7 6.1
150 200 250 300 350 400 450 500 600
9.8 11.3 12.5 13.7 14.6 15.5 16.5 17.4 19.2
立管导向支架间的允许间距
气体管道/m 公称直径/mm
光管 隔热 光管 隔热
液体管道/m
600
19.2
18
13.4
13.4
装置内平管管道基本跨距
气体管道/m 公称直径/mm 光管 隔热 光管 隔热 液体管道/m
40
4.99
3.12-4.07
4.7
3.02-3.89
表1 公称直径/mm 25 40 50 80 100 光管 4.3 5.2 5.8 7 7.9
表2
说明:以上数据均选自《化工工艺设计手册(下册)》,表2中数据 选取的是原表中最小的数值,隔热水平管道跨距与隔热层厚度有关。
装置内平管管道基本跨距 气体管道/m 液体管道/m 光管 隔热 光管 隔热 3.06 无数据 3 无数据 3.62 无数据 3.55 无数据 4.17 2.3-3.11 3.99 2.28-3.01 4.57 2.67-3.39 4.31 2.6-3.27 4.99 3.12-4.07 4.7 3.02-3.89 5.63 3.95-5.04 5.26 3.78-4.76 6.48 4.81-6.01 5.97 4.53-5.57 7.02 5.33-6.78 6.41 4.98-6.19 7.73 6.02-7.46 6.95 5.59-6.7 8.54 6.7-8.46 7.54 6.11-7.38 9.32 7.46-9.65 8.18 6.83-8.26 10.92 9.16-12.04 9.56 8.5-10.1 12.09 10.28-13.47 10.36 9.33-10.87 13.07 11.16-14.44 11.02 9.82-11.36 13.96 12.03-15.48 11.59 10.29-11.83 14.71 12.69-16.35 12.07 10.58-12.2 15.48 13.45-17.21 12.55 10.95-12.54 16.13 14.1-17.94 12.76 11.2-12.81 17.31 15.2-19.01 13.03 11.59-13.18 18.26 16.16-20 13.23 11.91-13.5 19.21 17.12-20.97 13.4 12.2-13.78 20.08 18.01-21.82 13.54 12.44-14.01 21.59 19-23.51 13.65 12.51-14.15 23.13 20.56-25.02 13.83 12.84-14.45 25.36 23.01-28.71 15.82 14.86-16.66 26.67 24.34-29.79 15.96 15.01-16.89
支架跨距计算(依据DLT-5054)20200508
序号名称符号计算公式或数据来源数值一1.1设计温度T 2501.2设计压力Pd 1.21.3管道外径Dw 3771.4管道壁厚δ091.5拟设计管道跨距L 101.6管道弹性模量Et 1880001.7管道内径Do3591.8管材密度7850.01.9管材重量800.451.10保温厚度1501.11保温材料密度801.12保温重量194.701.13介质密度蒸汽5.01.14介质重量 4.961.15保护层厚度彩钢板0.501.16保护层密度7850.01.17保护层重量81.871.18管道单位长度计算荷载q 10821.19跨中集中荷载P 01.20管道截面惯性矩I 17624.01.21最大弯曲挠度δmax 4.2521.22最大允许间距L max8.755说明:按刚度计算管道跨距计算1、本表参照DLT5054-2016计算,数据取值参考DLT5366-2006;2、水平布置的管道应控制一定的支吊架间距,以保证管道不产生过大的挠度、弯曲应力和剪切应力。
3、刚度条件应按单跨管道简支梁计算,其最大挠度值不应大于2.5mm;4、管道跨距计算结果取刚度、强度结果较小值。
单位序号名称符号计算公式或数据来源一℃ 1.1设计温度T Mpa.g 1.2设计压力Pd mm 1.3管道外径Dw mm 1.4管道壁厚δ0m 1.5管道弹性模量Et Mpa 1.6管道内径Do mm 1.7管材密度kg/m3 1.8管材重量N/m 1.9保温厚度mm 1.10保温材料密度kg/m3 1.11保温重量N/m 1.12介质密度蒸汽kg/m 1.13介质重量N/m 1.14保护层厚度彩钢板mm 1.15保护层密度kg/m3 1.16保护层重量N/m 1.17跨中集中荷载P N/m 1.18管道单位长度计算荷载q N 1.19管道截面系数W cm4 1.20管道允许最大弯曲应力σmax mm 1.21计算最大跨距Lm说明:1、本表参照按强度计算管道跨距计算2、刚度条件应按单跨管道简支梁计算,管道自重引起的最大弯曲应力不应大于16MPa;挠度、弯曲应力和剪切3、管道跨距计算结果取刚度、强度结果较小值。
管道跨距计算表
Do 钢管外径325设计压力(Mpa) 2.5管道中介质密度N/m 39800S 钢管公称壁厚10设计温度100钢管单位长度重量N/m 761.26公称直径腐蚀裕量1.5许用应力(Mpa)130mm 不保温保温不保温壁厚负偏差0.125E t 弹性模量(Mpa)19100025.0 4.3 3.4 4.040.0 5.2 4.0 4.6S 管道壁厚7.2550.0 5.8 4.6 4.9Di 内径310.580.07.0 6.1 6.1W 管道抗弯截面模量562091.5100.07.97.0 6.7I 截面惯性距91339868150.09.88.87.9qw 管道中单位水重715.64200.011.310.18.8q 每米管道总重量1476.90250.012.511.69.8σθ 环向应力54.78300.013.712.810.4350.014.613.410.7L,m19.76400.015.514.311.3L,m12.86L,m 15.82气体管道液体管道气体管道15 2.9 2.8 2.220 3.6 3.4 2.725 4.3 4.1 3.532 4.9 4.6 3.940 5.5 5.1 4.550 6.5 6.0 5.3657.87.1 6.6808.77.77.410010.08.68.512511.49.59.915012.810.611.320015.813.114.325018.415.316.430020.616.818.935022.618.020.840023.618.822.0裸管保温裸管25390022003450404850280040005054503300430080670040504950100765048005300150940057505950200107506800645025012000760069503001300082507350350137508700760040014700945077504501565010150785050016450110008400最大跨距(mm)水+ 保温3/4”~2”30003”~6”50008”~14”600016”~Above 8000立管导向支架间的允许间距(某院内定值,m 气体管道液体管道按照强度条件确定的管道最大允许跨距装置外按照刚度条件确定的管道最大允许跨距常用壁厚钢管最大允许跨距参考值(某院内定值DN 最大跨距 (m)不保温管道保温管道垂直管道最大跨距表DN海川waaabc制作,表格没有加密,欢迎转载,尊重作者,请不要删除本行谢谢!(出自《压力管道应力分析》)管道壁厚 10S的不锈钢管道最大跨矩表DN 最大跨距 (mm)气体介质液体介质装置内安装刚度条件确定的管道最大允许跨距保温公称直径最大间距公称直径最大间距3.4mm m mm m 3.715 3.52512.74.32044013.75.525 4.55015.26.140 5.56518.37.35068019.88.280710022.99.4100815024.410.1150920027.410.42001025030.511.02501130033.53001235036.63501340038.14001445041.46001650042.78001860045.7液体管道2.22.73.43.84.35.06.16.87.78.79.812.313.815.917.218.1保温2100260030003500400046005200565060506300655067507300值,m)垂直管道最大导向间距水平管道最大导向间距体管道内定值)(m)温管道析》)适用于压力≤1.57MPa,温度≤250℃,保温材料容重≤150kg/m 3矩表(mm)体介质。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
20.6
16.8
18.9
350
22.6
18.0
20.8
400
23.6
18.8
22.0
管道壁厚 10S的不锈钢管道最大跨矩表
最大跨距 (mm)
DN
气体介质
液体介质
裸管
保温
裸管
25
3900
2200
3450
40
4850
2800
4000
50
5450
3300
4300
80
6700
4050
4950
100
7650
4800
5300
150
9400
5750
5950
200
10750
6800
6450
250
12000
7600
6950
300
13000
8250
7350
350
13750
8700
7600
400
14700
9450
7750
450
15650
10150
7850
500
16450
11000
8400
DN
3/4”~2” 3”~6” 8”~14” 16”~Above
20
3.6
3.4
2.7
25
4.3
4.1
3.5
32
4.9
4.6
3.9
40
5.5
5.1
4.5
50
6.5
6.0
5.3
65
7.8
7.1
6.6
80
8.7
7.7
7.4
100
10.0
8.6
8.5
125
11.4
9.5
9.9
150
12.8
10.6
11.3
200
15.8
13.1
14.3
250
18.4
15.3
16.4
300
适用于压力≤1.57MPa,温度≤250℃,保温材料容重≤150kg/m3
表
m
15
3.5
25
12.7
20
4
40
13.7
25
4.5
50
15.2
40
5.5
65
18.3
50
6
80
19.8
80
7
100
22.9
100
8
150
24.4
150
9
200
27.4
200
10
250
30.5
250
11
300
33.5
300
12
350
36.6
350
13
400
38.1
400
14
450
41.4
600
16
500
管 钢道 管中 单介 位质 长密 度度 重N量/m3 N/m
9800 761.26
立管导向支架间的允许间距(某院内定值,m)
公称直径
气体管道
液体管道
mm
不保温
保温
不保温
0.125 Et 弹性模量 (Mpa)
191000
25.0
4.3
3.4
4.0
40.0
5.2
4.0
4.6
7.25
50.0
5.8
4.6
4.9
42.7
800
18
600Leabharlann 45.7值(某院内定值) 距 (m)
保温管道 液体管道 2.2 2.7 3.4 3.8 4.3 5.0 6.1 6.8 7.7 8.7 9.8 12.3 13.8 15.9 17.2 18.1
最大跨矩表 (mm)
液体介质 保温 2100 2600 3000 3500 4000 4600 5200 5650 6050 6300 6550 6750 7300
310.5
80.0
7.0
6.1
6.1
562091.5
100.0
7.9
7.0
6.7
91339868
150.0
9.8
8.8
7.9
715.64
200.0
11.3
10.1
8.8
1476.90
250.0
12.5
11.6
9.8
54.78
300.0
13.7
12.8
10.4
按照强度条件确定的管道最大允许跨距
350.0
Do 钢管外径 S 钢管公称壁厚 腐蚀裕量
壁厚负偏差
S 管道壁厚 Di 内径 W 管道抗弯截面模量 I 截面惯性距 qw 管道中单位水重 q 每米管道总重量 σθ 环向应力
L,m
L,m
L,m
出自《压力管道应力分析》
325 设计压力(Mpa) 10 设计温度 1.5 许用应力(Mpa)
2.5 100 130
垂直管道最大跨距表 最大跨距
(mm) 水+ 保温
3000 5000 6000 8000
某院内定值,m) 液体管道 保温 3.4
3.7 4.3 5.5 6.1 7.3 8.2 9.4 10.1
10.4 11.0
垂直管道最大导向间 水平管道最大导向间
距
距
公称直径 最大间距 公称直径 最大间距
mm
m
mm
14.6
13.4
10.7
19.76
400.0
15.5
14.3
11.3
装置内安装刚度条件确定的管道最大允许跨距
12.86 装置外按照刚度条件确定的管道最大允许跨距
15.82
常用壁厚钢管最大允许跨距参考值(某院内定值)
最大跨距 (m)
DN
不保温管道
保温管道
气体管道 液体管道 气体管道
15
2.9
2.8
2.2